WorldWideScience

Sample records for barium enemaexclamation radiographic

  1. Histological and radiographic evaluation of polymethylmethacrylate with two different concentrations of barium sulfate in a sheep vertebroplasty model.

    Science.gov (United States)

    Kobayashi, Naomi; Togawa, Daisuke; Fujishiro, Takaaki; Powell, Kimberly A; Turner, A Simon; Seim, Howard B; Bauer, Thomas W

    2005-10-01

    Percutaneous vertebral augmentation with PMMA has been widely performed and usually provides good pain relief and stabilization of fractured vertebrae. Adequate visualization of PMMA during injection is desirable to minimize cement extravasation, so contrast agents such as barium sulfate are commonly added to the PMMA. The aim of this study was to evaluate the differences of histology and radiographic visualization when different concentrations of barium sulfate are mixed with PMMA. Six sheep were utilized in this study. Three vertebrae of each animal were exposed via retroperitoneal approach, and a cavity was created and then filled with either 10% or 30% BaSO4/PMMA, or left empty. Vertebrae were harvested and analyzed radiographically and histologically 12 and 90 days after surgery. Average CT value of the 30% BaSO4/PMMA group was 2.4-fold higher than that of the 10% BaSO4/PMMA group. Foreign-body giant cells were recognized around BaSO4particles at 90 days in the 30% BaSO4 group, whereas few particles were recognized in the 10% group at 90 days, or in either group at 12 days. A very mild giant-cell reaction is induced by a higher concentration of BaSO4 in PMMA, but the marked improvement in cement visualization by increased BaSO4 may be important to minimize more serious complications of cement extravasation during PMMA injection.

  2. Barium periostitis: an intraoral complication following barium swallow.

    Science.gov (United States)

    Stanton, David C; Seeger, Douglas; Robinson, Brian T

    2007-05-01

    Barium is used with great frequency for various gastrointestinal radiographic studies. Complications arising from the use of barium are uncommon and can range from peritonitis, pneumonitis, vascular intravasation, allergic reactions, and even "barium appendicitis." We report a case of an unusual complication, periostitis, from the use of barium in a 46-year-old male.

  3. Hereditary nonpolyposis colorectal cancer: not just a barium enema{exclamation_point} Radiographic manifestations and screening tools

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.; Jeon, P. [Health Sciences Center, Diagnostic Imaging, St. John' s, Newfoundland (Canada)]. E-mail: u43dlb@mun.ca; Green, J. [Health Sciences Center, Discipline of Genetics, Faculty of Medicine, St. John' s, Newfoundland (Canada)

    2007-10-15

    Hereditary nonpolyposis colorectal cancer (HNPCC) is an autosomal dominant trait characterized by presentation of colorectal cancer (CRC) at an early age and by an increased risk of other primary malignancies, including those of the endometrium. ovaries, stomach, small bowel, upper biliary tract, skin, and brain, as well as by transitional cell carcinoma (TCC) that especially involves the renal pelvis and ureter. Because specific genetic mutations causing HNPCC have been recently discovered, genetic screening options have been developed for some families. Subsequently, radiology has an increasing role in surveillance for and management of these HNPCC-associated tumours. Although colonoscopy is the mainstay of a screening regimen for colon cancer, the barium enema has been a standard radiologic investigation. Further, computed tomography (CT) colonography (now practised in various centres) will, with further refinement, prove to be of increasing value. Ultrasonography is a standard investigation for endometrial and ovarian cancer, with CT and magnetic resonance (MR) imaging often playing a central role. As for TCC, intravenous urography (IVU) had been a standard investigation tool. However, with continued evolution of multidetector row CT with postprocessing manipulation (CT urography [CTU]), the role of IVU is diminishing in most centres. Newfoundland has a high prevalence of HNPCC exhibiting a broad range of manifestations. In this article, radiologic images of various tumours from individuals with HNPCC demonstrate a radiologic spectrum of this fascinating hereditary disease. Screening implications and specific screening methods are reviewed. (author)

  4. Solar eclipse sign of intussusception on barium enema.

    Science.gov (United States)

    Raveenthiran, V

    2002-01-01

    The colographic appearance of intussusception is variously described as a claw sign, pincer defect, shouldering effect, and coiled-spring pattern. This report adds a new radiographic sign to the list. An end-on view of an intussusception on barium enema shows a ring of contrast resembling a solar eclipse. Familiarity with this bizarre appearance is desirable, lest it may be mistaken for spillage of barium due to a colonic perforation.

  5. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    2007-01-01

    . Methods The study is designed as an observational study with a narrative approach. The participant observations took place in a Danish radiological department and involved 20 examinations followed up by three semi-structured interviews. Conclusions Through emergent narratives radiographers construct...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology....

  6. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  7. Study on Effectiveness of Barium Enema in the Diagnosis of Hirschsprung Disease

    Directory of Open Access Journals (Sweden)

    M. Karami Chanlah

    2005-08-01

    Full Text Available Introduction & Aims: The study aims to investigate barium enema accuracy in diagnosing Hischsprung's disease (HD. Patients & Methods: This study was performed on 58 patients diagnosed with Hischsprung's disease later confirmed by pathology; the patients had undergone surgical operation in the last 3 years. The radiographs were reached from their medical records and were later assessed by a skilled pediatric radiologist. Bar-ium enema findings were also evaluated. Rectosig-moid index with the sign of transitional zone (TZ, and barium evacuation of delayed radiographs were recorded by a radiologist. Results: We measured accuracy of rectosigmoid index in these patients to be 94.8%, the sign of TZ to be 70.7%, and the barium evacuation of delayed radio-graphs to be 100% for diagnosis of HD. Fifty percent of the cases were neonates, 42% infants, and 7% more than 2 years old. Of all the patients, 76% were male and 24% were female. The most common diseases accompanying HD were cardiac abnormalities. We did not find any total aganglionosis. Conclusion & Discussion: Half of the patients were newborn infants. The fact that the ratio is more than usual shows timely diagnosis of the condition by phy-sicians of this center. Barium enema findings in new-borns of our study contradicted significantly the re-searches done in other countries. In this study, it was found that with increasing age, barium enema find-ings would be defined in such a way that in in-fantsover 2 years, it can reach a diagnosis accuracy of up to 100%. Regarding the availability of barium en-ema and its lower costs than other diagnostic meth-ods, its accuracy seems very promising. Our study emphasizes that perhaps with barium enema, we may operate these infants in one stage so that they can get rid of multiphasic operation difficulties.

  8. Colonic transit time in patient with slow-transit constipation: Comparison of radiopaque markers and barium suspension method

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huimin [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China); Department of General Surgery, Weifang People' s Hospital, ShanDong Province 261041 (China); Han Jiagang [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China); Na Ying [Department of Medical Imaging, Weifang People' s Hospital, ShanDong Province 261041 (China); Zhao Bo; Ma Huachong [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China); Wang Zhenjun, E-mail: wang3zj@sohu.com [Department of General Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongtina Lu, Chaoyang District, Beijing 100020 (China)

    2011-08-15

    Background: Colonic transit study provides valuable information before surgical treatment is considered for patient with constipation. The radiopaque markers method is the most common way for evaluating colon transit time. The aim of this study is to compare the barium suspension with the radiopaque makers to assess the colonic mobility in patient with constipation. Methods: Colonic transit time was measured in 11 female patients with slow-transit constipation using both radiopaque markers and barium suspension method. In radiopaque markers method, the patient ingested 20 markers on the first day, and an abdominal radiograph was performed every 24 h until 80% markers were excreted. In barium suspension method, the patient swallowed up to 50 ml of 200% (w/v) barium meal. The abdominal radiographs were taken at the same time point as the former. Results: The total or segmental colonic transit time were obviously prolonged in all patients. Segmental transits time spent in the right colon, left colon and rectosigmoid for radiopaque markers and barium suspension method was, respectively, 30 {+-} 6 h and 34 {+-} 7 h; 38 {+-} 9 h and 32 {+-} 6 h; 40 {+-} 8 h and 38 {+-} 10 h. In the radiopaque markers method, total colonic transit time was 108 {+-} 14 h and it was 103 {+-} 13 h in the barium suspension method (P > 0.05). Conclusion: The barium suspension and radiopaque markers gave the similar results for colonic transit time. The barium suspension was a simple and cheap method for evaluating the colonic mobility.

  9. Controlling barium sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Greenley, R.

    Even though for several years success has been realized in controlling barium sulfate scale deposition in relatively shallow, low pressure oil wells--by squeezing an organic phosphonate scale inhibitor into the producing zone--barium sulfate scale depositon in deep, high pressure/high temperature wells usually meant an expensive workover operation. A case history of a deep (16,000 ft) well in St. Mary Parish, Louisiana, and the scale inhibitor squeeze operation are described. Based on the successful results obtained in treating this well, a generalized treating procedure for combating downhole scale deposition in high pressure/high temperature gas wells is presented. Formation squeezing with such an inhibitor represents a significant breakthrough for the oil and gas industry.

  10. On barium oxide solubility in barium-containing chloride melts

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaeva, Elena V.; Zakiryanova, Irina D.; Bovet, Andrey L.; Korzun, Iraida V. [Ural Federal Univ., Yekaterinburg (Russian Federation). Inst. of High Temperature Electrochemistry

    2016-11-01

    Oxide solubility in chloride melts depends on temperature and composition of molten solvent. The solubility of barium oxide in the solvents with barium chloride content is essentially higher than that in molten alkali chlorides. Spectral data demonstrate the existence of oxychloride ionic groupings in such melts. This work presents the results of the BaO solubility in two molten BaCl{sub 2}-NaCl systems with different barium chloride content. The received data together with earlier published results revealed the main regularities of BaO solubility in molten BaO-BaCl{sub 2}-MCl systems.

  11. MR Colonography with fecal tagging: Barium vs. barium ferumoxsil

    DEFF Research Database (Denmark)

    Achiam, M.P.; Chabanova, E.; Logager, V.B.;

    2008-01-01

    and Methods. Twenty patients referred to CC underwent dark lumen MRC prior to the colonoscopy. Two groups of patients received two different oral contrast agents (barium sulfate and barium sulfate/ferumoxsil) as a laxative-free fecal tagging prior to the MRC. After MRC, the contrast agent was rated...... qualitatively (with the standard method using contrast-to-wall ratio) and subjectively (using a visual analog scale [VAS]) by three different blinded observers. Results. Evaluated both qualitatively and subjectively, the tagging efficiency of barium sulfate/ferumoxsil was significantly better (P ... barium sulfate alone. The VAS method for evaluating the tagging efficiency of contrast agents showed a high correlation (observer 11, r = 0.91) to the standard method using contrast-to-wall ratio and also a high interclass correlation (observer 11 and III = 0.89/0.85). MRC found I of 22 (5%) polyps

  12. Doped barium titanate nanoparticles

    Indian Academy of Sciences (India)

    T K Kundu; A Jana; P Barik

    2008-06-01

    We have synthesized nickel (Ni) and iron (Fe) ion doped BaTiO3 nanoparticles through a chemical route using polyvinyl alcohol (PVA). The concentration of dopant varies from 0 to 2 mole% in the specimens. The results from X-ray diffractograms and transmission electron micrographs show that the particle diameters in the specimen lie in the range 24–40 nm. It is seen that the dielectric permittivity in doped specimens is enhanced by an order of magnitude compared to undoped barium titanate ceramics. The dielectric permittivity shows maxima at 0.3 mole% doping of Fe ion and 0.6 mole% of Ni ion. The unusual dielectric behaviour of the specimens is explained in terms of the change in crystalline structure of the specimens.

  13. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough

    Directory of Open Access Journals (Sweden)

    Carlos Shuler Nin

    2013-12-01

    Full Text Available OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough.METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons.RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6% of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6% of the patients, whereas the treatment was ineffective in 1 (8.4%. We observed no complications related to barium swallow, such as contrast aspiration.CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  14. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  15. 75 FR 33824 - Barium Chloride From China

    Science.gov (United States)

    2010-06-15

    ... COMMISSION Barium Chloride From China Determination On the basis of the record\\1\\ developed in the subject... order on barium chloride from China would be likely to lead to continuation or recurrence of material... Barium Chloride from China: Investigation No. 731-TA-149 (Third Review). By order of the...

  16. An 8-year review of barium studies in the diagnosis of gastroparesis

    Energy Technology Data Exchange (ETDEWEB)

    Levin, A.A. [Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, PA (United States); Levine, M.S. [Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, PA (United States)], E-mail: marc.levine@uphs.upenn.edu; Rubesin, S.E.; Laufer, I. [Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, PA (United States)

    2008-04-15

    Aim: To determine the utility of barium studies for diagnosing gastroparesis in patients with nausea, vomiting, or other related symptoms. Materials and methods: Radiology files revealed gastroparesis without gastric outlet obstruction on upper gastrointestinal tract barium studies in 50 patients with nausea, vomiting, and other related symptoms. Original reports and images were reviewed to determine whether gastric peristalsis was decreased/absent and to investigate gastric dilatation, fluid or debris, and delayed emptying of barium. Twenty patients (40%) had nuclear gastric emptying studies. Medical records were reviewed to determine the presentation, treatment, and course. The diagnosis of gastroparesis was considered accurate if patients with gastroparesis on barium studies responded to treatment. Results: Forty-six patients (92%) had predisposing factors for gastroparesis, including narcotics and diabetes. Forty-five patients (90%) presented with nausea or vomiting, and 40 patients (80%) had one or more other symptoms, including bloating, early satiety, postprandial fullness, and abdominal pain. Barium studies revealed decreased gastric peristalsis in 46 (92%) of the 50 patients and absent peristalsis in four (8%); 46 patients (92%) had additional findings, including gastric dilatation in 30 (60%), delayed emptying of barium in 27 (54%), debris in 28 (56%; bezoars in three), and retained fluid in 13 (26%). Thirteen (65%) of 20 patients with nuclear gastric emptying studies had delayed emptying of solids and seven (35%) had normal emptying. Thirty-five (83%) of 42 patients treated for gastroparesis had symptomatic improvement versus two (25%) of eight patients not treated. Conclusion: Patients with nausea, vomiting, or other related symptoms who have gastroparesis without gastric outlet obstruction on barium studies can be treated for this condition on the basis of the clinical and radiographic findings.

  17. Radiographic Assessment for Back Pain

    Science.gov (United States)

    Radiographic Assessment for Back Pain What are Radiographic Assessments? When Should I get an X-ray for Low Back Pain? Other Reasons for Having an X-ray What ... What are Radiographic Assessments? Radiographic assessments for low back pain involve the use of X-rays to determine ...

  18. Barium aspiration and alveolarisation of barium in an infant: A case report and review of management

    Directory of Open Access Journals (Sweden)

    Alan F. Isles

    2014-05-01

    Full Text Available We describe a case of bilateral inhalation and alveolarisation of barium in an infant following a barium swallow for investigation of dusky spells associated with feeds. A bronchoscopy subsequently revealed the presence of a mid-tracheal tracheo-oesophageal cleft. We review the literature on barium aspiration, its consequences and make recommendations for management.

  19. ONE CASE REPORT OF ACUTE POISONING BY BARIUM CARBONATE

    Institute of Scientific and Technical Information of China (English)

    GE Qin-min; BIAN Fan; WANG Shu-yun; SHEN Sheng-hui

    2009-01-01

    @@ Most barium poisoning cases were caused by oral intake by mistake. Recent years, barium carbonate poisoning has been rare to be reported. Here we reported a case of acute barium carbonate toxication taken orally on purpose.

  20. Barium Swallow Findings in the Evaluation of Patients with Dysphagia

    Directory of Open Access Journals (Sweden)

    Amirhosein Hashemi Attar

    2011-05-01

    Full Text Available Background/Objective: Dysphagia is a subjective"nsensation of difficulty in swallowing that has a wide"nrange of etiologies from psychosomatic disorders"nto high grade neoplasms. In this study we evaluated"nbarium swallow findings of patients with dysphagia."nPatients and Methods: We evaluated 200 patients"n(117 men, 83 women; mean age, 49.6 years with"ncomplaint of dysphagia. Fluoroscopic barium"nswallow was done for all the patients and they were"nreviewed for primary peristalsis (presence or absence,"nAbstracts"nS62 Iran J Radiol 2011, 8 (Supp.1"nAbstracts"nimpaired lower esophageal sphincter, esophageal dilatation, delayed emptying of barium, nonperistaltic contractions, stricture and filling defects. Clinical and in some cases endoscopic or manometric follow up was done for all patients."nResults: We had 134 (67% normal barium swallow"nexams with uncomplicated clinical courses. Sixty"nsix patients (33% had abnormal imaging findings"nincluding stricture in 24 patients (12%, filling defect"nin 12 patients (6% and mucosal abnormality in 14"n(7% patients (six cases of mucosal irregularity, three"ncases of mucosal ulceration and five cases of mucosal"nherniation, Bird's beak sign in three patients (1.5%,"ntertiary spasm in six patients (3% and hiatal hernia in"nseven patients (3.5%."nConclusion: In the majority of patients with dysphagia,"nbarium swallow is the only paraclinical study needed"nto plan proper treatment. If radiographic findings are"nequivocal, endoscopy or manometry may be required"nfor more certain diagnosis.

  1. Processing science of barium titanate

    Science.gov (United States)

    Aygun, Seymen Murat

    Barium titanate and barium strontium titanate thin films were deposited on base metal foils via chemical solution deposition and radio frequency magnetron sputtering. The films were processed at elevated temperatures for densification and crystallization. Two unifying research goals underpin all experiments: (1) To improve our fundamental understanding of complex oxide processing science, and (2) to translate those improvements into materials with superior structural and electrical properties. The relationships linking dielectric response, grain size, and thermal budget for sputtered barium strontium titanate were illustrated. (Ba 0.6Sr0.4)TiO3 films were sputtered on nickel foils at temperatures ranging between 100-400°C. After the top electrode deposition, the films were co-fired at 900°C for densification and crystallization. The dielectric properties were observed to improve with increasing sputter temperature reaching a permittivity of 1800, a tunability of 10:1, and a loss tangent of less than 0.015 for the sample sputtered at 400°C. The data can be understood using a brick wall model incorporating a high permittivity grain interior with low permittivity grain boundary. However, this high permittivity value was achieved at a grain size of 80 nm, which is typically associated with strong suppression of the dielectric response. These results clearly show that conventional models that parameterize permittivity with crystal diameter or film thickness alone are insufficiently sophisticated. Better models are needed that incorporate the influence of microstructure and crystal structure. This thesis next explores the ability to tune microstructure and properties of chemically solution deposited BaTiO3 thin films by modulation of heat treatment thermal profiles and firing atmosphere composition. Barium titanate films were deposited on copper foils using hybrid-chelate chemistries. An in-situ gas analysis process was developed to probe the organic removal and the

  2. 75 FR 19657 - Barium Chloride From China

    Science.gov (United States)

    2010-04-15

    ... COMMISSION Barium Chloride From China AGENCY: United States International Trade Commission. ACTION: Notice of... chloride from China. SUMMARY: The Commission hereby gives notice that it will proceed with a full review... revocation of the antidumping duty order on barium chloride from China would be likely to lead...

  3. Laser cooling and trapping of barium

    NARCIS (Netherlands)

    De, Subhadeep

    2008-01-01

    Laser cooling and trapping of heavy alkaline-earth element barium have been demonstrated for the first time ever. For any possible cycling transition in barium that could provide strong cooling forces, the excited state has a very large branching probability to metastable states. Additional lasers a

  4. Peritoneal tuberculosis: radiographic diagnosis

    Directory of Open Access Journals (Sweden)

    Carolina Ospina-Moreno

    2014-12-01

    Full Text Available Peritoneal tuberculosis (TB is an extrapulmonary form of presentation of tuberculosis. HIV infection is a primary risk factor for this condition. Diagnosis requires microbiological or histopathological confirmation in addition to supporting radiological imaging studies. Abdominal ultrasonography and CT are useful to obtain a radiographic diagnosis, with typical findings including diffuse peritoneal thickening, presence of ascites in varying volumes, adenopathies, and caseating nodes. We report 2 cases of patients with ascites and nodular peritoneal thickening on diagnostic images, as well as high CA-125 levels in laboratory tests. In both patients, a diagnosis of peritoneal tuberculosis was reached following a US-guided peritoneal biopsy.

  5. Magneto optical trapping of Barium

    CERN Document Server

    De, S; Jungmann, K; Willmann, L

    2008-01-01

    First laser cooling and trapping of the heavy alkaline earth element barium has been achieved based on the strong 6s$^2$ $^1$S$_0$ - 6s6p $^1$P$_1$ transition for the main cooling. Due to the large branching into metastable D-states several additional laser driven transitions are required to provide a closed cooling cycle. A total efficiency of $0.4(1) \\cdot 10^{-2}$ for slowing a thermal atomic beam and capturing atoms into a magneto optical trap was obtained. Trapping lifetimes of more than 1.5 s were observed. This lifetime is shortened at high laser intensities by photo ionization losses. The developed techniques will allow to extend significantly the number of elements that can be optically cooled and trapped.

  6. Radium/Barium Waste Project

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, Allen K.; Ellefson, Mark D.; McDonald, Kent M.

    2015-06-25

    The treatment, shipping, and disposal of a highly radioactive radium/barium waste stream have presented a complex set of challenges requiring several years of effort. The project illustrates the difficulty and high cost of managing even small quantities of highly radioactive Resource Conservation and Recovery Act (RCRA)-regulated waste. Pacific Northwest National Laboratory (PNNL) research activities produced a Type B quantity of radium chloride low-level mixed waste (LLMW) in a number of small vials in a facility hot cell. The resulting waste management project involved a mock-up RCRA stabilization treatment, a failed in-cell treatment, a second, alternative RCRA treatment approach, coordinated regulatory variances and authorizations, alternative transportation authorizations, additional disposal facility approvals, and a final radiological stabilization process.

  7. Early manifestation of Yersinia colitis demonstrated by the double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Aspestrand, F.

    1986-11-01

    A 19-year old female with a bloody, diarrheal illness of acute onset where Crohn's disease primarly was suspected is presented. The double-contrast barium enema revealed multiple, diffusely scattered aphthous erosions of the colonic mucosa: the rectum was scarcely affected. Biopsies taken by endoscopy demonstrated nonspecific inflammatory changes of the mucous membrane. However, routinely taken stool cultures revealed an infectious colitis due to Yersinia enterocolitica. Our case demonstrates the necessity to consider Yersinia enterocolitis in the radiographic differential diagnosis when the diagnosis of Crohn's disease or ulcerative colitis seems obvious.

  8. 75 FR 20625 - Barium Chloride From China

    Science.gov (United States)

    2010-04-20

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Barium Chloride From China AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: April 9, 2010. FOR FURTHER INFORMATION CONTACT:...

  9. Neutral Barium Cloud Evolution at Different Altitudes

    Institute of Scientific and Technical Information of China (English)

    李磊; 徐荣栏

    2002-01-01

    Considering the joint effects of diffusion, collision, oxidation and photoionization, we study the evolution of the barium cloud at different altitudes in the space plasma active experiment. The results present the variation of the loss rate, number density distribution and brightness of the barium cloud over the range from 120 to 260km.This can be divided into oxidation, oxidation plus photoionization and photoionization regions.

  10. Small barium rail gun for plasma injection.

    Science.gov (United States)

    Kiwamoto, Y

    1980-03-01

    A small rail gun with a barium electrode can be operated at higher than one shot per second to produce more than 2x10(16) barium ions with energy 10-20 eV. The operation of the gun takes advantage of the external magnetic field for cross-field plasma injection into a trap. Up to 7 kG of the magnetic field examined, the gun performance improves with the increased magnetic field strength.

  11. Bacterial Reduction Of Barium Sulphate By Sulphate-Reducing Bacteria

    Directory of Open Access Journals (Sweden)

    Luptáková Alena

    2015-12-01

    Full Text Available Acid mine drainage (AMD is a worldwide problem leading to contamination of water sources. AMD are characterized by low pH and high content of heavy metals and sulphates. The barium salts application presents one of the methods for the sulphates removing from AMD. Barium chloride, barium hydroxide and barium sulphide are used for the sulphates precipitation in the form of barium sulphate. Because of high investment costs of barium salts, barium sulphide is recycled from barium sulphate precipitates. It can be recycled by thermic or bacterial reduction of barium sulphate. The aim of our study was to verify experimentally the possibility of the bacterial transformation of BaSO4 to BaS by sulphate-reducing bacteria. Applied BaSO4 came from experiments of sulphates removal from Smolnik AMD using BaCl2.

  12. The future for the radiographer

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    2007-01-01

    implemented reporting as a part of the radiographers line of work. They report on peripheral skeleton and ultrasoundexaminations which they have done for quite some time now, and the next move will be the pelvis and the vertebral column. The implementation of the reporting radiographers has contributed...

  13. Thermochemical hydrogen production via a cycle using barium and sulfur - Reaction between barium sulfide and water

    Science.gov (United States)

    Ota, K.; Conger, W. L.

    1977-01-01

    The reaction between barium sulfide and water, a reaction found in several sulfur based thermochemical cycles, was investigated kinetically at 653-866 C. Gaseous products were hydrogen and hydrogen sulfide. The rate determining step for hydrogen formation was a surface reaction between barium sulfide and water. An expression was derived for the rate of hydrogen formation.

  14. Sulphate removal from sodium sulphate-rich brine and recovery of barium as a barium salt mixture.

    Science.gov (United States)

    Vadapalli, Viswanath R K; Zvimba, John N; Mulopo, Jean; Motaung, Solly

    2013-01-01

    Sulphate removal from sodium sulphate-rich brine using barium hydroxide and recovery of the barium salts has been investigated. The sodium sulphate-rich brine treated with different dosages of barium hydroxide to precipitate barium sulphate showed sulphate removal from 13.5 g/L to less than 400 mg/L over 60 min using a barium to sulphate molar ratio of 1.1. The thermal conversion of precipitated barium sulphate to barium sulphide achieved a conversion yield of 85% using coal as both a reducing agent and an energy source. The recovery of a pure mixture of barium salts from barium sulphide, which involved dissolution of barium sulphide and reaction with ammonium hydroxide resulted in recovery of a mixture of barium carbonate (62%) and barium hydroxide (38%), which is a critical input raw material for barium salts based acid mine drainage (AMD) desalination technologies. Under alkaline conditions of this barium salt mixture recovery process, ammonia gas is given off, while hydrogen sulfide is retained in solution as bisulfide species, and this provides basis for ammonium hydroxide separation and recovery for reuse, with hydrogen sulfide also recoverable for further industrial applications such as sulfur production by subsequent stripping.

  15. Synthesis of barium mercaptides and application of antimony/barium mercaptides

    Institute of Scientific and Technical Information of China (English)

    瞿龙; 张露露; 舒万艮

    2001-01-01

    Mercaptoacetic acid, isooctyl thioglycolate and barium hydroxide used as start materials, barium bis (2-ethylhexyl thioglycolate) (Ba(2EHTG)2), barium thioglycolate (Ba(TG)) and barium bisthioglycolate (Ba(TG)2) were synthesized. Their optimum synthetic techniques were discussed, and some physicochemical data were reported. Infrared spectroscopy and elemental analysis methods were used to identify the structures. They were put into PVC plastic products together with antimony tris (2-ethylhexyl thioglycolate) (Sb(2EHTG)3) under the suitable compounding, and their heat stability to PVC was studied. It is shown that these barium mercaptides have remarkable synergisms with antimony mercaptides and the long-term stabilizing effect of organoantimony stabilizer can be effectively improved, reducing the amount of antimony compounds so as to avoid the decrease of its stabilizing effect.

  16. Abundance analysis of Barium stars

    Institute of Scientific and Technical Information of China (English)

    Guo-Qing Liu; Yan-Chun Liang; Li-Cai Deng

    2009-01-01

    We obtain the chemical abundances of six barium stars and two CH subgiant stars based on the high signal-to-noise ratio and high resolution Echelle spectra. The neu- tron capture process elements Y, Zr, Ba, La and Eu show obvious overabundances relative to the Sun, for example, their [Ba/Fe] values are from 0.45 to 1.27. Other elements, in- cluding Na, Mg, A1, Si, Ca, Sc, Ti, V, Cr, Mn and Ni, show comparable abundances to the Solar ones, and their [Fe/H] covers a range from -0.40 to 0.21, which means they belong to the Galactic disk. The predictions of the theoretical model of wind accretion for bi- nary systems can explain the observed abundance patterns of the neutron capture process elements in these stars, which means that their overabundant heavy-elements could be caused by accreting the ejecta of AGB stars, the progenitors of present-day white dwarf companions in binary systems.

  17. Chest radiographic findings of leptospirosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mee Hyun; Jung, Hee Tae; Lee, Young Joong; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1986-04-15

    1. A study on chest radiographic findings of 54 cases with pneumonia like symptoms was performed. Of 54 cases, 8 cases were confirmed to be leptospirosis and 7 cases were leptospirosis combined with Korean hemorrhagic fever. 2. Of 8 cases of leptospirosis, 4 cases showed abnormal chest radiographic findings: acinar nodular type 2, massive confluent consolidation type 2. Of 7 cases of leptospirosis combined with Korean hemorrhagic fever: acinar nodular type 3, massive confluent consolidation type 1, and increased interstitial markings type 1 respectively. 3. It was considered to be difficult to diagnose the leptospirosis on chest radiographic findings alone, especially the case combined with Korean hemorrhagic fever.

  18. Coherent Dark Resonances in Atomic Barium

    CERN Document Server

    Dammalapati, U; Jungmann, K; Willmann, L

    2007-01-01

    The observation of dark-resonances in the two-electron atom barium and their influence on optical cooling is reported. In heavy alkali earth atoms, i.e. barium or radium, optical cooling can be achieved using n^1S_0-n^1P_1 transitions and optical repumping from the low lying n^1D_2 and n^3D_{1,2} states to which the atoms decay with a high branching ratio. The cooling and repumping transition have a common upper state. This leads to dark resonances and hence make optical cooling less inefficient. The experimental observations can be accurately modelled by the optical Bloch equations. Comparison with experimental results allows us to extract relevant parameters for effective laser cooling of barium.

  19. Improved spectrophotometric analysis of barium styphnate

    Energy Technology Data Exchange (ETDEWEB)

    Brown, N E; Blasi, J A

    1983-01-01

    A spectrophotometric procedure to determine the purity of barium styphnate monohydrate based upon the absorbance of the styphnate ion at 326 and 413.3 nm has been developed. The purity is determined by comparing the absorbance of the styphnate ion in barium styphnate and in styphnic acid. Our investigation has shown that the molar absorptivity and lambda maxima of the styphnate ion are quite pH dependent; therefore, the pH is buffered to 6.8 to 7.0 with ammonium acetate. Under these conditions the molar absorptivity is 1.6 x 10/sup 4/ L/mol-cm. Analyses following the procedure in the Navy specification WS13444A using water were found to give low molar absorptivities (1.3 x 10/sup 4/ L/mol-cm) for the styphnic acid calibration resulting in erroneous values for barium styphnate purity.

  20. Radiographic findings in liveborn triploidy.

    Science.gov (United States)

    Silverthorn, K G; Houston, C S; Newman, D E; Wood, B J

    1989-01-01

    The detailed radiographic features of triploidy, a fatal congenital disorder with 69 chromosomes, have not previously been reported. Radiographs of ten liveborn infants with chromosomally confirmed triploidy showed six findings highly suggestive of this diagnosis: harlequin orbits, small anterior fontanelle, gracile ribs, diaphyseal overtubulation of long bones, upswept clavicles and antimongoloid pelvis. Sixteen other less specific findings showed many similarities to those found in trisomy 18.

  1. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  2. Radiographic findings in liveborn triploidy

    Energy Technology Data Exchange (ETDEWEB)

    Silverthorn, K.G.; Houston, C.S.; Newman, D.E.; Wood, B.J.

    1989-05-01

    The detailed radiographic features of triploidy, a fatal congenital disorder with 69 chromosomes, have not previously been reported. Radiographs of ten liveborn infants with chromosomally confirmed triploidy showed six findings highly suggestive of this diagnosis: Harlequin orbits, small anterior fontanelle, gracile ribs, diaphyseal overtubulation of long bones, upswept clavicles and antimongoloid pelvis. Sixteen other less specific findings showed many similarities to those found in trisomy 18.

  3. Radiographic study of mandibular asymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Yeon Hwa; Cho, Bong Hae [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    1998-02-15

    The purpose of this study was to perform the radiographic measurements and temporomandibular joint evaluation in mandibular asymmetry. For this study, thirty-two patients who have mandibular asymmetry were selected and submentovertex, panoramic and lateral corrected tomographic radiographs were taken. Horizontal and vertical analysis using various landmarks on these radiographs were performed. Also radiographic and clinical evaluation of temporomandibular joint were obtained. The results were as follows: 1. On the submentovertex radiograph, the mean distance of Pogonion to midline was 5.0 {+-} 3.8 mm. 2. The mean distance of Pogonion to Gonion between the deviated and the contra-lateral side (p<0.001). 3. The distance difference of Pogonion to Gonion between the deviated and the contra-lateral side was significantly related to the degree of asymmetry (p<0.001). 4. On panoramic radiograph,the condylar height of the contral-lateral side was significantly longer than the one of the deviated side (p<0.001). 5. On lateral corrected tomogram, bony of temporomandibular joint was observed in 11 condyles of the deviated side and 9 condyles of the contra-lateral side. Erosion and ostephyte were the most common changes in both the deviated and the contra-lateral sides.

  4. Printed Barium Strontium Titanate capacitors on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Sette, Daniele [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg); Kovacova, Veronika [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Defay, Emmanuel, E-mail: emmanuel.defay@list.lu [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg)

    2015-08-31

    In this paper, we show that Barium Strontium Titanate (BST) films can be prepared by inkjet printing of sol–gel precursors on platinized silicon substrate. Moreover, a functional variable capacitor working in the GHz range has been made without any lithography or etching steps. Finally, this technology requires 40 times less precursors than the standard sol–gel spin-coating technique. - Highlights: • Inkjet printing of Barium Strontium Titanate films • Deposition on silicon substrate • Inkjet printed silver top electrode • First ever BST films thinner than 1 μm RF functional variable capacitor that has required no lithography.

  5. Electronic structure of nanograin barium titanate ceramics

    Institute of Scientific and Technical Information of China (English)

    DENG Xiangyun; WANG Xiaohui; LI Dejun; LI Longtu

    2007-01-01

    The density of states and band structure of 20 nm barium titanate(BaTiO3,BT)ceramics are investigated by first-principles calculation.The full potential linearized augmented plane wave(FLAPW)method is used and the exchange correlation effects are treated by the generalized gradient approximation(GGA).The results show that there is substantial hybridization between the Ti 3d and O 2p states in 20 nm BT ceramics and the interaction between barium and oxygen is typically ionic.

  6. Plain abdominal radiographs in children with inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, G.A.; Nancarrow, P.A.; Hernanz-Schulman, M.; Teele, R.L.

    1986-03-01

    The value of plain abdominal radiography in children with inflammatory bowel disease (IBD) has not been ascertained. We reviewed the scout radiographs prior to first barium examination in 100 children with IBD (53 Crohn, 47 ulcerative colitis (UC) and scout films prior to excretory urography in 50 patients who had no clinical evidence of intestinal disease (controls)). The films were reviewed without clinical information, and the abnormalities on each film scored according to severity and location. Criteria included: mural thickening, dilatation and mucosal abnormalities of the small bowel and colon, as well as abnormal quantity and/or distribution of feces in the colon. Eighty percent (40/50) of the films in the control group were interpreted as normal. Abnormalities suggestive of IBD were presented in 73% of the IBD group (76% Crohn and 72% UC). Thirty-one percent of the films in the IBD group had a moderately abnormal score (>=3) or markedly abnormal score (>=5) at presentation. The most reliable radiographic findings were: mucosal abnormality in the colon and small bowel and an abnormal stool pattern (feces completely absent or only present in one colonic segment). The clinical presentation of IBD in childhood is often vague and nonspecific. Abnormalities in plain films of the abdomen are common in these patients and may be helpful in suggesting the presence and, to a great degree, the severity of disease in these children.

  7. Barium Ferrite Films Grown by Laser Ablation

    NARCIS (Netherlands)

    Lisfi, A.; Lodder, J.C.; Haan, de P.; Smithers, M.A.; Roesthuis, F.J.G.

    1998-01-01

    Pulsed laser ablation (PLA) has been used to grow barium ferrite films on Al2O3 single crystal substrates. When deposition occurs in an oxidising atmosphere at high temperatures, the films are single BaFe12O19 phase, very well oriented with (001) texture, and exhibit a large perpendicular magnetic a

  8. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, J.P. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Duarte, G.W. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Research Group in Technology and Information, Centro Universitário Barriga Verde (UNIBAVE), Santa Catarina, SC (Brazil); Caldart, C. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Kniess, C.T. [Post-Graduate Program in Professional Master in Management, Universidade Nove de Julho, São Paulo, SP (Brazil); Montedo, O.R.K.; Rocha, M.R. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Riella, H.G. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Fiori, M.A., E-mail: fiori@unochapeco.edu.br [Post-Graduate Program in Environmental Science, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil); Post-Graduate Program in Technology and Management of the Innovation, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil)

    2015-11-15

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound.

  9. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  10. Monitoring Radiographic Brain Tumor Progression

    Directory of Open Access Journals (Sweden)

    John H. Sampson

    2011-03-01

    Full Text Available Determining radiographic progression in primary malignant brain tumors has posed a significant challenge to the neuroncology community. Glioblastoma multiforme (GBM, WHO Grade IV through its inherent heterogeneous enhancement, growth patterns, and irregular nature has been difficult to assess for progression. Our ability to detect tumor progression radiographically remains inadequate. Despite the advanced imaging techniques, detecting tumor progression continues to be a clinical challenge. Here we review the different criteria used to detect tumor progression, and highlight the inherent challenges with detection of progression.

  11. Chemical abundances and kinematics of barium stars

    CERN Document Server

    de Castro, D B; Roig, F; Jilinski, E; Drake, N A; Chavero, C; Silva, J V Sales

    2016-01-01

    In this paper we present an homogeneous analysis of photospheric abundances based on high-resolution spectroscopy of a sample of 182 barium stars and candidates. We determined atmospheric parameters, spectroscopic distances, stellar masses, ages, luminosities and scale height, radial velocities, abundances of the Na, Al, $alpha$-elements, iron-peak elements, and s-process elements Y, Zr, La, Ce, and Nd. We employed the local-thermodynamic-equilibrium model atmospheres of Kurucz and the spectral analysis code {\\sc moog}. We found that the metallicities, the temperatures and the surface gravities for barium stars can not be represented by a single gaussian distribution. The abundances of $alpha$-elements and iron peak elements are similar to those of field giants with the same metallicity. Sodium presents some degree of enrichment in more evolved stars that could be attributed to the NeNa cycle. As expected, the barium stars show overabundance of the elements created by the s-process. By measuring the mean heav...

  12. Analysis of 26 Barium Stars I. Abundances

    CERN Document Server

    Allen, D M; Allen, Dinah M.; Barbuy, Beatriz

    2006-01-01

    We present a detailed analysis of 26 barium stars, including dwarf barium stars, providing their atmospheric parameters (Teff, log g, [Fe/H], vt) and elemental abundances. We aim at deriving gravities and luminosity classes of the sample stars, in particular to confirm the existence of dwarf barium stars. Accurate abundances of chemical elements were derived. Abundance ratios between nucleosynthetic processes, by using Eu and Ba as representatives of the r- and s-processes are presented. High-resolution spectra with the FEROS spectrograph at the ESO-1.5m Telescope, and photometric data with Fotrap at the Zeiss telescope at the LNA were obtained. The atmospheric parameters were derived in an iterative way, with temperatures obtained from colour-temperature calibrations. The abundances were derived using spectrum synthesis for Li, Na, Al, alpha-, iron peak, s- and r-elements atomic lines, and C and N molecular lines. Atmospheric parameters in the range 4300 < Teff < 6500, -1.2 < [Fe/H] < 0.0 and 1.4...

  13. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or...

  14. Lanthanide doped strontium-barium cesium halide scintillators

    Science.gov (United States)

    Bizarri, Gregory; Bourret-Courchesne, Edith; Derenzo, Stephen E.; Borade, Ramesh B.; Gundiah, Gautam; Yan, Zewu; Hanrahan, Stephen M.; Chaudhry, Anurag; Canning, Andrew

    2015-06-09

    The present invention provides for a composition comprising an inorganic scintillator comprising an optionally lanthanide-doped strontium-barium, optionally cesium, halide, useful for detecting nuclear material.

  15. History and challenges of barium titanate: Part I

    Directory of Open Access Journals (Sweden)

    Vijatović M.M.

    2008-01-01

    Full Text Available Barium titanate is the first ferroelectric ceramics and a good candidate for a variety of applications due to its excellent dielectric, ferroelectric and piezoelectric properties. Barium titanate is a member of a large family of compounds with the general formula ABO3 called perovskites. Barium titanate can be prepared using different methods. The synthesis method depends on the desired characteristics for the end application. The used method has a significant influence on the structure and properties of barium titanate materials. In this review paper, Part I contains a study of the BaTiO3 structure and frequently used synthesis methods.

  16. Thermochemical hydrogen production via a cycle using barium and sulfur: reaction between barium sulfide and water

    Energy Technology Data Exchange (ETDEWEB)

    Ota, K.; Conger, W.L.

    1977-01-01

    The reaction between barium sulfide and water, a reaction found in several sulfur based thermochemical cycles, was investigated kinetically at 653 to 866/sup 0/C. Gaseous products were hydrogen and hydrogen sulfide. The rate determining step for hydrogen formation was a surface reaction between barium sulfide and water. The rate of formation of hydrogen can be expressed as: RH2 = 1.07 x 10/sup -2/ exp (-3180/RT) (mol H/sub 2//mol BaS s). Hydrogen sulfide was produced during the initial period of reaction and the quantity of hydrogen sulfide formed during this period decreased as the temperature of reaction was increased.

  17. HADES, A Radiographic Simulation Code

    Energy Technology Data Exchange (ETDEWEB)

    Aufderheide, M.B.; Slone, D.M.; Schach von Wittenau, A.E.

    2000-08-18

    We describe features of the HADES radiographic simulation code. We begin with a discussion of why it is useful to simulate transmission radiography. The capabilities of HADES are described, followed by an application of HADES to a dynamic experiment recently performed at the Los Alamos Neutron Science Center. We describe quantitative comparisons between experimental data and HADES simulations using a copper step wedge. We conclude with a short discussion of future work planned for HADES.

  18. Pulmonary edema: radiographic differential diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong [Dankook Univ. College of Medicine, Chonan (Korea, Republic of)

    1997-04-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema.

  19. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  20. Radiography and image-intensified fluoroscopy of barium passage through the gastrointestinal tract in six healthy Amazon parrots (Amazona aestiva).

    Science.gov (United States)

    Vink-Nooteboom, Mariette; Lumeij, J T; Wolvekamp, W T C

    2003-01-01

    Gastrointestinal contrast studies were performed in six clinically healthy blue-fronted Amazon parrots (Amazona aestiva) using radiography and image-intensified fluoroscopy. During examination, the birds were confined in a perspex cage. The quality of the lateral radiographs was adequate for assessment of the contrast medium-filled gastrointestinal tract. Thirty minutes after administration of 20 mL/kg of a 25% barium sulphate suspension directly in the crop, in all birds the ventriculus was totally outlined by barium. After 60 min, the small intestine was filled in five of six birds. After 180 min, the crop was empty in all birds. The barium-outlined ventriculus had differences in shape on radiographs of individual birds and also between birds. The colon and cloaca had further filling after 120 to 300 min. With image-intensified fluoroscopy, gastrointestinal motility was evaluated. Contractions of the crop were seen, and boluses of contrast medium passing through the esophagus toward the proventriculus were easily identified. Proventricular contractions were rarely noted, but ventriculus motility was present and clearly defined. The ventriculus had a mean of 3.7 contraction cycles/min. In the duodenum and small intestine, rapid antegrade and retrograde peristaltic movements in combination with segmental contractions were seen. In the colon, occasionally very slow peristaltic activity, mainly of segmental nature, was present. During the examinations, no defeacation was recorded. Confinement in a small perspex cage provides an adequate and handy radiological set-up for evaluation of gastrointestinal passage and motility in birds, minimizing the influences of stress and anesthesia.

  1. Barium enema findings of milk allergy in infants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyoung Ju; Kim, Mi Jeong; Lee, Hee Jung [Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2006-09-15

    We wanted to evaluate the barium enema findings of milk allergy in infants. Retrospective evaluation of the plain abdominal radiography and barium enema findings was performed in fifteen young infants suffering with milk allergy. The presence of gaseous distension, rectal gas, paralytic ileus and mechanical obstruction was evaluated on the plain radiography. The presence of spasm, a transitional zone, a reversed rectosigmoid index and mucosal irregularity was analyzed on the barium enema; the presence of barium retention was also evaluated on 24-hour-delayed plain radiography. Paralytic ileus was the most common finding on the plain radiography (93%). On the barium enema, continuous spasm of the colon, ranging from the rectum to the descending colon, was revealed in ten infants (67%). A transitional zone was observed in one infant and a reversed rectosigmoid index was revealed in four. Mucosal irregularity was observed in two infants. Barium retention was demonstrated in 11 of fifteen cases: throughout the entire colon (n = 3), from the rectum to the descending colon (n = 7), and up to the transverse colon (n = 1). The most common barium enema finding of milk allergy in infants was spasm of the distal colon. The other findings were a transitional zone, a reversed rectosigmoid index, mucosal irregularity and barium retention.

  2. [Silica, aluminum, iron, sulfur, and barium in a urinary calculus].

    Science.gov (United States)

    Rodríguez-Miñón Cifuentes, J L; Salvador, E; Bellanato, J; Medina, J A

    1994-05-01

    Presentation of the analytical results by Sweep Microscopy of a small papillary calculus spontaneously eliminated after a nephritic colic. The main component is monohydrate calcium oxalate. When the stone core was analyzed with EDAX, silica, aluminium, iron, sulphur and barium were detected. The origin of these elements is discussed and the presence of barium emphasized as exceptional.

  3. Scattering lengths of calcium and barium isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dammalapati, U.; Willmann, L.; Knoop, S. [Kernfysisch Versneller Instituut (KVI), University of Groningen, Zernikelaan 25, 9747 AA Groningen (Netherlands); LaserLaB Vrije Universiteit, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands)

    2011-11-15

    We have calculated the s-wave scattering length of all the even isotopes of calcium (Ca) and barium (Ba) in order to investigate the prospect of Bose-Einstein condensation (BEC). For Ca we have used an accurate molecular potential based on detailed spectroscopic data. Our calculations show that Ca does not provide other isotopes alternative to the recently Bose condensed {sup 40}Ca that suffers strong losses because of a very large scattering length. For Ba we show by using a model potential that the even isotopes cover a broad range of scattering lengths, opening the possibility of BEC for at least one of the isotopes.

  4. Barium appendicitis: A single institution review in Japan

    Science.gov (United States)

    Katagiri, Hideki; Lefor, Alan Kawarai; Kubota, Tadao; Mizokami, Ken

    2016-01-01

    AIM To review clinical experience with barium appendicitis at a single institution. METHODS A retrospective review of patients admitted with a diagnosis of acute appendicitis, from January 1, 2013 to December 31, 2015 was performed. Age, gender, computed tomography (CT) scan findings if available, past history of barium studies, pathology, and the presence of perforation or the development of complications were reviewed. If the CT scan revealed high density material in the appendix, the maximum CT scan radiodensity of the material is measured in Hounsfield units (HU). Barium appendicitis is defined as: (1) patients diagnosed with acute appendicitis; (2) the patient has a history of a prior barium study; and (3) the CT scan shows high density material in the appendix. Patients who meet all three criteria are considered to have barium appendicitis. RESULTS In total, 396 patients were admitted with the diagnosis of acute appendicitis in the study period. Of these, 12 patients (3.0%) met the definition of barium appendicitis. Of these 12 patients, the median CT scan radiodensity of material in the appendix was 10000.8 HU, ranging from 3066 to 23423 HU (± 6288.2). In contrast, the median CT scan radiodensity of fecaliths in the appendix, excluding patients with barium appendicitis, was 393.1 HU, ranging from 98 to 2151 HU (± 382.0). The CT scan radiodensity of material in the appendices of patients with barium appendicitis was significantly higher than in patients with nonbarium fecaliths (P < 0.01). CONCLUSION Barium appendicitis is not rare in Japan. Measurement of the CT scan radiodensity of material in the appendix may differentiate barium appendicitis from routine appendicitis.

  5. The radiographic appearances of non-specific small intestinal ulceration

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Thomas H.; Jackson, James E

    2002-02-01

    AIM: To determine the imaging characteristics of non-specific ulceration of the small intestine. MATERIALS AND METHODS: The radiographic investigations undertaken in three patients originally referred for visceral angiography in whom a histological diagnosis of non-specific ulceration of the small bowel was subsequently made were retrospectively reviewed. Two men and one woman aged from 17 to 24 years all presented with anaemia requiring blood transfusion. Visceral angiography was available for review in all three patients, abdominal computed tomography in two, and a small bowel enema and white cell scintigraphy in one. RESULTS: In all three patients an angiographic abnormality was present within the ileum consisting of irregularity of the vasa recta, an area of subtle increased vascularity and early venous return. A long, non-branching vessel interpreted as a persistent vitello-intestinal artery was seen in two of these patients. A CT abnormality was present in two individuals consisting of a focal area of thickened small bowel. The single small bowel enema demonstrated a focal stricture and the white cell scan showed localized accumulation of radioactivity within the pelvis. CONCLUSION: Non-specific small intestinal ulceration may produce abnormalities that are discernible on barium studies, computed tomography, radiolabelled white cell scanning and visceral angiography. Recognition of these findings may allow a pre-operative diagnosis of this condition. Bryant, T.H. and Jackson, J.E. (2001)

  6. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  7. Radiographic survey of perlite workers.

    Science.gov (United States)

    Cooper, W C

    1975-05-01

    Chest roentgenograms of 240 perlite workers employed for 1 to 23 years in the industry, showed no evidence of pneumoconiosis associated with perlite exposures. One individual, found to have simple pneumoconiosis, and one found to have complicated pneumoconiosis, had formerly been diatomaceous earth workers. Since only 28 of the men had been in the industry over 15 years and only seven for 20 years or more, continued surveillance is essential to make sure that there are no effects with more prolonged exposures. Studies of pulmonary function of the individuals who have had relatively long exposures are needed to supplement radiographic evidence.

  8. The Novel Formation of Barium Titanate Nanodendrites

    Directory of Open Access Journals (Sweden)

    Chien-Jung Huang

    2014-01-01

    Full Text Available The barium titanate (BaTiO3 nanoparticles with novel dendrite-like structures have been successfully fabricated via a simple coprecipitation method, the so-called BaTiO3 nanodendrites (BTNDs. This method was remarkable, fast, simple, and scalable. The growth solution is prepared by barium chloride (BaCl2, titanium tetrachloride (TiCl4, and oxalic acid. The shape and size of BaTiO3 depend on the amount of added BaCl2 solvent. To investigate the influence of amount of BaCl2 on BTNDs, the amount of BaCl2 was varied in the range from 3 to 6 mL. The role of BaCl2 is found to have remarkable influence on the morphology, crystallite size, and formation of dendrite-like structures. The thickness and length of the central stem of BTND were ~300 nm and ~20 μm, respectively. The branchings were found to occur at irregular intervals along the main stem. Besides, the formation mechanism of BTND is proposed and discussed.

  9. NANOSCALE BARIUM HYDROSILICATES: CHOOSING THE SYNTHESIS TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    GRISHINA Anna Nikolaevna

    2013-08-01

    Full Text Available Cement concretes are the most used materials in modern civil engineering. Due to that such materials draw great attention both in the Russian Federation and abroad. The possibility to enhance the manufacturability and operational properties of concretes results in significant reduction of overall operating costs. Many enhancement methods have been elaborated. Among them there is one based on introduction of calcium hydrosilicates into construction composition. The authors set up a hypothesis that similarity between properties and structures of different hydrosilicates (for example, alkaline earth metals and metals of the second group will provide similar increased operational characteristics. The specialists of Research and Educational Center «Nanotechnology» are developing cement composites nanomodification methods which include introduction of nanodimensional barium hydrosilicates particles. The synthesis of barium hydrosilicates particles can be done with the use of many technologies, different by energy consumption or performing complexity. Taking into account both these factors, one can assume that low-temperature sol-gel synthesis from diluted water solutions is the proper technology. The present paper shows that this assumption is correct. The selection of certain technology is made by the means of multiobjective optimization, which is in turn is performed by the means of linear scalarization. This method, while not always giving the Pareto optimal solutions, can be easily implemented. The particle size distribution is taken into consideration during selection of objectives and weights. It is shown that selected technology allows manufacturing nanoparticles with median size about 30 nm.

  10. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  11. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  12. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  13. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  14. Clinical Applications of Successive Spot Radiographs in Esophagography for Diagnosing the Early Esophageal Cancer

    Institute of Scientific and Technical Information of China (English)

    TANGLi-jun; KONGFan-fu; WANGDe-hang

    2004-01-01

    To introduce primary experience of clinical applications of successive spot radiographs in esophagography for the din mlosis of early esoplmgeal cancer (EEC). Methods: Six patients with EEC were examined and doagnosed dlaarmsed by a digital X-ray machine. According to the routine double contrast study of esophagus, the patient gulped a barimn suspension in the upright position when the successive films were taken by 2 frmnes per second lasting for about 10 seconds. Various phases were obtained including barimn-filled views,mucosal relief views and double contrast views. Results: Functional changes and abnormal mucosal folds of esophagus were present on successive spot radiographs of esophagography in patients with EEC and those patients with EEC were confirmed by endoscopic and pathologic findings. Four patients had mild loss of distensibility, 2 patients had spasmodic contraction and 1 patient had barium retention. Thickened or interrupted folds were found in all cases.Little niches were detected in 5 of 6 patients. Conctusion: Evidence presented in barimn studies of esophagus is more comprehensive and intact for the diagnosis of EEC when successive spot radiographs are employed. Functional changes of esophagus are more evident with this approach.

  15. Strengthening mechanism of steels treated by barium-bearing alloys

    Institute of Scientific and Technical Information of China (English)

    Zhouhua Jiang; Yang Liu

    2008-01-01

    The deoxidation, desulfurization, dephosphorization, microstructure, and mechanical properties of steels treated by barium-bearing alloys were investigated in laboratory and by industrial tests. The results show that barium takes part in the deoxidation reaction at the beginning of the experiments, generating oxide and sulfide compound inclusions, which easily float up from the molten steel, leading to the rapid reduction of total oxygen content to a very low level. The desulfurization and dephosphorization capabilities of calcium-bearing alloys increase with the addition of barium. The results of OM and SEM observations and mechanical property tests show that the structure of the steel treated by barium-bearing alloys is refined remarkably, the iamellar thickness of pearlitic structure decreases, and the pearlitic morphology shows clustering distribution. Less barium exists in steel substrate and the enrichment of barium-bearing precipitated phase mostly occurs in grain boundary and phase boundary, which can prevent the movement of grain boundary and dislocation during the heat treatment and the deformation processes. Therefore, the strength and toughness of barium-treated steels are improved by the effect of grain-boundary strengthening and nail-prick dislocation.

  16. Barium concentration in grain of Aegilops and Triticum species

    Directory of Open Access Journals (Sweden)

    Denčić Srbislav S.

    2015-01-01

    Full Text Available The aim of this study was to evaluate the concentration of barium in grain of various Aegilops and Triticum species with different genomes. The studied species differed significantly with respect to the concentration of barium. The grain of wild diploid Aegilops speltoides, the donor of B genome, contained significantly higher Ba concentration than all other analyzed genotypes. Wild and cultivated tetraploid wheats (Triticum diciccoides, Triticum dicoccon, Triticum turgidum and Triticum durum had the lowest Ba concentration in grain. The modern cultivated hexaploid varieties presented substantial variation in grain concentration of barium. The highest Ba concentration (3.42 mg/kg occurred in Serbian winter wheat variety Panonnia.

  17. Chemical abundance analysis of 19 barium stars

    CERN Document Server

    Yang, G C; Spite, M; Chen, Y Q; Zhao, G; Zhang, B; Liu, G Q; Liu, Y J; Liu, N; Deng, L C; Spite, F; Hill, V; Zhang, C X

    2016-01-01

    We aim at deriving accurate atmospheric parameters and chemical abundances of 19 barium (Ba) stars, including both strong and mild Ba stars, based on the high signal-to-noise ratio and high resolution Echelle spectra obtained from the 2.16 m telescope at Xinglong station of National Astronomical Observatories, Chinese Academy of Sciences. The chemical abundances of the sample stars were obtained from an LTE, plane-parallel and line-blanketed atmospheric model by inputting the atmospheric parameters (effective temperatures, surface gravities, metallicity and microturbulent velocity) and equivalent widths of stellar absorption lines. These samples of Ba stars are giants indicated by atmospheric parameters, metallicities and kinematic analysis about UVW velocity. Chemical abundances of 17 elements were obtained for these Ba stars. Their light elements (O, Na, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn and Ni) are similar to the solar abundances. Our samples of Ba stars show obvious overabundances of neutron-capture (n-ca...

  18. Analysis of europium doped luminescent barium thioaluminate

    Institute of Scientific and Technical Information of China (English)

    张东璞; 喻志农; 薛唯; 章婷; 丁瞾; 王武育

    2010-01-01

    Europium-doped barium thioaluminate sputtering target was synthesized by powder sintering method and thin film was deposited by radio frequency(RF) sputtering.X-ray diffractometer(XRD) pattern indicated that the main compound of the target was BaAl4S7.Oxygen was the main impurity which led to the formation of BaAl2O4.It was shown that both BaAl4S7 and BaAl2S4 were contained in the as-grown thin films and a 471.7 nm emission peak in the PL spectra appeared due to a combination of BaAl4S7:Eu2+ and BaAl2S4:Eu2...

  19. Radiographic study of the odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyung Kyu [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1983-11-15

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  20. Gout: radiographic findings mimicking infection

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, I.; Raymond-Tremblay, D. [Dept. of Diagnostic Radiology, Centre Hospitalier de l' Univ. de Montreal, Que. (Canada); Cardinal, E. [Dept. of Radiology, Centre Hospitalier de l' Univ. de Montreal, Que. (Canada); Beauregard, C.G. [Dept. of Diagnostic Radiology, Hopital du Sacre-Coeur de Montreal,Que. (Canada); Braunstein, E.M. [Dept. of Radiology, Indiana University Hospital (United States); Saint-Pierre, A. [Rheumatology Unit, Centre Hospitalier de l' Univ. de Montreal, Que. (Canada)

    2001-10-01

    Objective: To describe radiographic features of gout that may mimic infection. Design and patients: We report five patients with acute bacterial gout who presented with clinical as well as radiological findings mimicking acute bacterial septic arthritis or osteomyelitis. Three patients had delay in the appropriate treatment with the final diagnosis being established after needle aspiration and identification of urate crystals under polarized light microscopy. Two patients underwent digit amputation for not responding to antibiotic treatment and had histological findings confirming the diagnosis of gout. Conclusion: It is important for the radiologist to be aware of the radiological manifestations of acute gout that can resemble infection in order to avoid inappropriate diagnosis and delay in adequate treatment. The definitive diagnosis should rely on needle aspiration and a specific search for urate crystals. (orig.)

  1. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  2. Automatic cobb angle determination from radiographic images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H.F.; Veldhuizen, Albert G.; Ooijen, van Peter M.A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Met

  3. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  4. Radiographic simulations and analysis for ASCI

    Energy Technology Data Exchange (ETDEWEB)

    Aufderheide, M.; Stone, D.; VonWittenau, A.

    1998-12-18

    In this paper, the authors describe their work on developing quantitatively accurate radiographic simulation and analysis tools for ASCI hydro codes. they have extended the ability of HADES, the code which simulates radiography through a mesh, to treat the complex meshes used in ASCI calculations. The ultimate goal is to allow direct comparison between experimental radiographs and full physics simulated radiographs of ASCI calculations. They describe the ray-tracing algorithm they have developed for fast, accurate simulation of dynamic radiographs with the meshes used in ALE3D, an LLNL ASCI code. Spectral effects and material compositions are included. In addition to the newness of the mesh types, the distributed nature of domain decomposed problems requires special treatment by the radiographic code. Because of the size of such problems, they have parallelized the radiographic simulation, in order to have quick turnaround time. presently, this is done using the domain decomposition from the hydro code. They demonstrate good parallel scaling as the size of the problem is increased. They show a comparison between an experimental radiograph of a high explosive detonation and a simulated radiograph of an ALE3D calculation. They conclude with a discussion of future work.

  5. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  6. Upper gastrointestinal barium evaluation of duodenal pathology: A pictorial review

    Institute of Scientific and Technical Information of China (English)

    Pankaj; Gupta; Uma; Debi; Saroj; Kant; Sinha; Kaushal; Kishor

    2014-01-01

    Like other parts of the gastrointestinal tract(GIT), duodenum is subject to a variety of lesions both congenital and acquired. However, unlike other parts of the GIT viz. esophagus, rest of the small intestine and large intestine, barium evaluation of duodenal lesions is technically more challenging and hence not frequently reported. With significant advances in computed tomography technology, a thorough evaluation including intraluminal, mural and extramural is feasible in a single non-invasive examination. Notwithstanding, barium evaluation still remains the initial and sometimes the only imaging study in several parts of the world. Hence,a thorough acquaintance with the morphology of various duodenal lesions on upper gastrointestinal barium examination is essential in guiding further evaluation. We reviewed our experience with various common and uncommon barium findings in duodenal abnormalities.

  7. A NOVEL HYDROTHERMAL SYNTHESIS METHOD FOR BARIUM FERRITE

    Institute of Scientific and Technical Information of China (English)

    Kang Li; Hongchen Gu; Qun Wei

    2004-01-01

    In the present work, fine barium ferrite powder has been synthesized through a one-step hydrothermal process in an autoclave at [OH-]/[Cl-] ratio of 2:1 in the temperature range from 180 to 260 ℃ using barium chloride (BaCl2), ferrous chloride (FeCl2) and potassium nitrate (KNO3) as the starting materials. Both particle size and saturation magnetization (Ms) increase with increasing hydrothermal reaction temperature, while the intrinsic coercivity (iHc) peaks at 685 Oe at 230 ℃. Morphology progress from the barium ferrite precursor particles to the barium hexaferrite particles has been monitored with increasing hydrothermal reaction time at 230 ℃ in the autoclave.

  8. Peritonite por bário Barium peritonitis

    Directory of Open Access Journals (Sweden)

    Gerson Alves Pereira Júnior

    1999-10-01

    Full Text Available We report a case of a 49 years-old man who underwent a barium meal examination for an epigastric pain. A perforated gastric ulcer with barium extravasation into peritoneal cavity was seen on X-rays. During an emergency laparotomy, a perforated pyloric ulcer was noted, along with barium contamination in the peritoneal cavity. The ulcer was closed with an omental patch and an extensive peritoneal lavage with saline was performed. During the postoperative period, the patient developed signs of peritonitis and underwent a new laparotomy was at the 9th day showing a subfrenic abscess with a large barium contamination. The patient presented septic shock and multiple organ failure. dying on the 21th day.

  9. Synthesis, photoluminescence and magnetic properties of barium vanadate nanoflowers

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jing [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China); Chongqing University of Science and Technology, Chongqing 401331 (China); Hu, Chenguo, E-mail: hucg@cqu.edu.cn [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China); Xi, Yi [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China); Peng, Chen [School of Physical Science and Technology, Southwest University, Chongqing 400715 (China); Wan, Buyong; He, Xiaoshan [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China)

    2011-06-15

    Graphical abstract: The flower-shaped barium vanadate was obtained for the first time. The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. Research highlights: {yields} In the paper, the flower-shaped barium vanadate were obtained for the first time. The CHM method used here is new and simple for preparation of barium vanadate. {yields} The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. The strong bluish-green emission was observed. {yields} The ferromagnetic behavior of the barium vanadate nanoflowers was found with saturation magnetization of about 83.50 x 10{sup -3} emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10{sup -3} emu/g. {yields} The mechanisms of PL and magnetic property of barium vanadate nanoflowers have been discussed. -- Abstract: The flower-shaped barium vanadate has been obtained by the composite hydroxide mediated (CHM) method from V{sub 2}O{sub 5} and BaCl{sub 2} at 200 {sup o}C for 13 h. XRD and XPS spectrum of the as-synthesized sample indicate it is hexagonal Ba{sub 3}V{sub 2}O{sub 8} with small amount of Ba{sub 3}VO{sub 4.8} coexistence. Scan electron microscope and transmission electron microscope display that the flower-shaped crystals are composed of nanosheets with thickness of {approx}20 nm. The UV-visible spectrum shows that the barium vanadate sample has two optical gaps (3.85 eV and 3.12 eV). Photoluminescence spectrum of the barium vanadate flowers exhibits a visible light emission centered at 492 and 525 nm which might be attributed to VO{sub 4} tetrahedron with T{sub d} symmetry in Ba{sub 3}V{sub 2}O{sub 8}. The ferromagnetic behavior of the barium vanadate nanoflowers has been found with saturation magnetization of about 83.50 x 10{sup -3} emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10{sup -3} emu/g, which is mainly due to the presence of a non

  10. Electrorheological behavior of rare earth-doped barium titanate suspensions

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Doping Y, La, Ce into barium titanate is found to be able to improve its electrorheological (ER) effect in DC electrical field. The yield stress of a typical doped barium titanate/silicone oil suspension is approximately 3.2 -*7〗kPa at 3.5 -*7〗kV/mm, which is 10 times larger than that of pure barium titanate/silicone oil suspensions. The ER effect increases with the decrease of ionic radius of rare earth (RE) dopant when RE concentration remains constant, and the suspensions exhibit a relatively high shear stress when Y, La, Ce mole fractions are 15%, 10%~15%, and 5%, respectively. Dielectric measurements show that the suitable doping with RE element increases dielectric loss of barium titanate and causes very marked dielectric relaxation at low frequency. By measuring X-ray diffraction patterns of doped barium titanate, it is considered that the occurrence of lattice distortion or defects may be responsible for the change of dielectric properties which results in the improvement of ER effect of barium titanate in DC electrical field.

  11. Lifetime Measurement for 6snp Rydberg States of Barium

    Institute of Scientific and Technical Information of China (English)

    SHEN Li; WANG Lei; YANG Hai-Feng; LIU Xiao-Jun; LIU Hong-Ping

    2011-01-01

    @@ We present a simple and efficient method for measuring the atomic lifetimes in order of tens of microseconds and demonstrate it in the lifetime determination of barium Rydberg states.This method extracts the lifetime information from the time-of-flight spectrum directly, which is much more efficient than other methods such as the time-delayed field ionization and the traditional laser induced fluorescence.The lifetimes determined with our method for barium Rydberg 6snp(n=37-59)series are well coincident with the values deduced from the absolute oscillator strengths of barium which were given in the literature [J.Phys.B 14(1981)4489, 29(1996)655]on experiments.%We present a simple and efficient method for measuring the atomic lifetimes in order of tens of microseconds and demonstrate it in the lifetime determination of barium Rydberg states. This method extracts the lifetime information from the time-of-flight spectrum directly, which is much more efficient than other methods such as the time-delayed field ionization and the traditional laser induced fluorescence. The lifetimes determined with our method for barium Rydberg 6snp (n=37-59) series are well coincident with the values deduced from the absolute oscillator strengths of barium which were given in the literature [J. Phys. B 14 (1981) 4489, 29 (1996) 655] onexperiments.

  12. Radiographic markers - A reservoir for bacteria?

    Energy Technology Data Exchange (ETDEWEB)

    Tugwell, Jenna, E-mail: jenna.tugwell@googlemail.co [Department of Radiology, Ysbyty Gwynedd Hospital, Bangor, North Wales (United Kingdom); Maddison, Adele [Nuffield Health, Shrewsbury Hospital (United Kingdom)

    2011-05-15

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  13. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  14. High H- ionic conductivity in barium hydride

    Science.gov (United States)

    Verbraeken, Maarten C.; Cheung, Chaksum; Suard, Emmanuelle; Irvine, John T. S.

    2015-01-01

    With hydrogen being seen as a key renewable energy vector, the search for materials exhibiting fast hydrogen transport becomes ever more important. Not only do hydrogen storage materials require high mobility of hydrogen in the solid state, but the efficiency of electrochemical devices is also largely determined by fast ionic transport. Although the heavy alkaline-earth hydrides are of limited interest for their hydrogen storage potential, owing to low gravimetric densities, their ionic nature may prove useful in new electrochemical applications, especially as an ionically conducting electrolyte material. Here we show that barium hydride shows fast pure ionic transport of hydride ions (H-) in the high-temperature, high-symmetry phase. Although some conductivity studies have been reported on related materials previously, the nature of the charge carriers has not been determined. BaH2 gives rise to hydride ion conductivity of 0.2 S cm-1 at 630 °C. This is an order of magnitude larger than that of state-of-the-art proton-conducting perovskites or oxide ion conductors at this temperature. These results suggest that the alkaline-earth hydrides form an important new family of materials, with potential use in a number of applications, such as separation membranes, electrochemical reactors and so on.

  15. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    degrees C and evidence was found for the solidification of the melt at 380-440 degrees C, i.e. simultaneously with the onset of decomposition. Between 400 degrees C and 520 degrees C (Ba(C4H9CO2)(2) decomposes in two main steps, first into BaCO3 with release of C4H9COC4H9 (5-nonanone), whereas final......The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...... conversion to BaO takes place with release of CO2. Elemental carbon that is left as a by-product is finally slowly burned by the residual oxygen present in the Ar atmosphere. (C) 2015 Elsevier B.V. All rights reserved....

  16. Chemical compositions of four barium stars

    CERN Document Server

    Liang, Y C; Chen, Y Q; Qiu, H M; Zhang, B

    2003-01-01

    Chemical compositions of four barium stars HD 26886, HD 27271, HD 50082 and HD 98839 are studied based on high resolution, high signal-to-noise Echelle spectra. Results show that all of them are disk stars. Their \\alpha and iron peak elements are similar to the solar abundances. The neutron-capture process elements are overabundant relative to the Solar. The heavy-element abundances of the strong Ba star HD 50082 are higher than those of other three mild Ba stars. Its mass is 1.32Msun (+0.28,-0.22Msun), and is consistent with the average mass of strong Ba stars (1.5Msun). For mild Ba star HD 27271 and HD 26886, the derived masses are 1.90Msun (+0.25,-0.20Msun) and 2.78Msun (+0.75,-0.78M_sun), respectively, which are consistent with the average mass of mild Ba stars. We also calculate the theoretical abundances of Ba stars by combining the AGB stars nucleosynthesis and wind accretion formation scenario of Ba binary systems. The comparisons between the observed abundance patterns of the sample stars with the th...

  17. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  18. Radiographic signs and diagnosis of dental disease.

    Science.gov (United States)

    Bellows, J

    1993-08-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats.

  19. MRI of radiographically occult ischial apophyseal avulsions

    Energy Technology Data Exchange (ETDEWEB)

    Meyers, Arthur B. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Children' s Hospital of Wisconsin, Milwaukee, WI (United States); Laor, Tal; Zbojniewicz, Andrew M.; Anton, Christopher G. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States)

    2012-11-15

    Acute avulsions of unossified ischial apophyses in children may go undetected on radiography. Therapy includes rest and rehabilitation; however, substantial displacement may require surgery. Our purpose is to illustrate the utility of MRI in the detection of these radiographically occult injuries in skeletally immature children. This retrospective study of more than 5 years included children with ischial avulsions who were evaluated with both radiography and MRI within 3 weeks of acute injury. Initially, radiographs were reviewed to identify those children with unossified ischial apophyses. Subsequently, their MRI examinations were assessed for physeal disruption, bone/soft tissue edema, periosteal/perichondrial elevation and disruption. Initial and follow-up radiographs (if available) were reviewed. Patient age, symptoms and offending activity were determined from clinical records. Five children met inclusion criteria. All initial radiographs were normal. MRI showed: edema (n = 5), periosteal elevation (n = 4), periosteal/perichondrial disruption (n = 4), >5.5 mm displacement (n = 0). Follow-up radiographs in two children (2 and 2.5 months from MRI) showed osseous ischial irregularity. The apophyses remained unossified. Acute unossified ischial apophyseal avulsions in children may be radiographically undetected. In the setting of correlative clinical symptoms, MRI can be used to identify these injuries and to help direct appropriate therapy. (orig.)

  20. Both barium and calcium activate neuronal potassium currents

    Energy Technology Data Exchange (ETDEWEB)

    Ribera, A.B.; Spitzer, N.C.

    1987-09-01

    Amphibian spinal neurons in culture possess both rapidly inactivating and sustained calcium-dependent potassium current components, similar to those described for other cells. Divalent cation-dependent whole-cell outward currents were isolated by subtracting the voltage-dependent potassium currents recorded from Xenopus laevis neurons in the presence of impermeant cadmium from the currents produced without cadmium but in the presence of permeant divalent cations. These concentrations of permeant ions were low enough to avoid contamination by macroscopic inward currents through calcium channels. Calcium-dependent potassium currents were reduced by 1 ..mu..M tetraethylammonium. These currents can also be activated by barium or strontium. Barium as well as calcium activated outward currents in young neurons (6-8 hr) and in relatively mature neurons (19-26 hr in vitro). However, barium influx appeared to suppress the sustained voltage-dependent potassium current in most cells. Barium also activated at least one class of potassium channels observed in excised membrane patches, whole blocking others. The blocking action may have masked and hindered detection of the stimulatory action of barium in other systems.

  1. Durability of Alite-calcium Barium Sulphoaluminate Cement

    Institute of Scientific and Technical Information of China (English)

    LU Lingchao; LU Zeye; LIU Shiquan; WANG Shoude; CHENG Xin

    2009-01-01

    The durability of the cement was mainly studied.Under 1.0 MPa of hydraulic pressure for 8 hours,water could penetrate completely through the sample made by portland cement,but could not penetrate through that by alite-barium sulphoaluminate cement.Under the condition of freezing and thawing cycle,the loss ratio of compressive strength of the cement was only about 17.3%at curing 28 d ages,but the loss of portland cement was as high as 29.5%.Alite-calcium bar-ium sulphoaluminate cement also has an excellent resistance to sulfate attack.The coefficients of resistance to sulfate attack of the cement exceeded 1.0.Meanwhile,the composition and microstructure of the hardened paste of alite-calcium barium sulphoaluminate cement were analyzed by XRD and SEM.

  2. Barium titanate thick films prepared by screen printing technique

    Directory of Open Access Journals (Sweden)

    Mirjana M. Vijatović

    2010-06-01

    Full Text Available The barium titanate (BaTiO3 thick films were prepared by screen printing technique using powders obtained by soft chemical route, modified Pechini process. Three different barium titanate powders were prepared: i pure, ii doped with lanthanum and iii doped with antimony. Pastes for screen printing were prepared using previously obtained powders. The thick films were deposited onto Al2O3 substrates and fired at 850°C together with electrode material (silver/palladium in the moving belt furnace in the air atmosphere. Measurements of thickness and roughness of barium titanate thick films were performed. The electrical properties of thick films such as dielectric constant, dielectric losses, Curie temperature, hysteresis loop were reported. The influence of different factors on electrical properties values was analyzed.

  3. Deoxidation Behavior of Alloys Bearing Barium in Molten Steel

    Institute of Scientific and Technical Information of China (English)

    LI Yang; JIANG Zhou-hua; JIANG Mao-fa; WANG Jun-wen; GU Wen-bing

    2003-01-01

    The deoxidation behaviors of alloys bearing barium in pipe steel were researched with MgO crucible under argon atmosphere in MoSi2 furnace at 1 873 K. The total oxygen contents of molten steel, the distribution, size and morphology of deoxidation products in the steel were surveyed. The metamorphic mechanism for deoxidation products of alloy bearing barium was also discussed. The results show that applying alloy bearing barium to the pipe steel, very low total oxygen contents can be obtained, and deoxidation products, which easily float up from molten steel, can be changed into globular shape and uniformly distributed in steel. The equilibrium time of total oxygen is about 25 min, and the terminal total oxygen contents range from 0.002 0 % to 0.002 2 % after treating with SiCa wire. The best deoxidizers are SiAlBaCa and SiAlBaCaSr.

  4. Barium-borate-flyash glasses: As radiation shielding materials

    Science.gov (United States)

    Singh, Sukhpal; Kumar, Ashok; Singh, Devinder; Thind, Kulwant Singh; Mudahar, Gurmel S.

    2008-01-01

    The attenuation coefficients of barium-borate-flyash glasses have been measured for γ-ray photon energies of 356, 662, 1173 and 1332 keV using narrow beam transmission geometry. The photon beam was highly collimated and overall scatter acceptance angle was less than 3°. Our results have an uncertainty of less than 3%. These coefficients were then used to obtain the values of mean free path (mfp), effective atomic number and electron density. Good agreements have been observed between experimental and theoretical values of these parameters. From the studies of the obtained results it is reported here that from the shielding point of view the barium-borate-flyash glasses are better shields to γ-radiations in comparison to the standard radiation shielding concretes and also to the ordinary barium-borate glasses.

  5. Reducing missing fracture clinic radiographs by entrusting them to patients.

    OpenAIRE

    Calder, Peter R.; Hynes, Matthew C.; Goodier, W. David

    2004-01-01

    BACKGROUND: Missing radiographs in fracture clinics may compromise fracture management and lead to inappropriate use of clerical resources. METHODS: We prospectively compared the number of missing radiographs in two hospitals over a period of two months. In hospital A the radiographs were retained and in hospital B they were entrusted to the patients. RESULTS: At the completion of the study, entrusting patients with their radiographs resulted in statistically less radiographs missing from the...

  6. 75 FR 36629 - Barium Chloride From the People's Republic of China: Continuation of Antidumping Duty Order

    Science.gov (United States)

    2010-06-28

    ... International Trade Administration Barium Chloride From the People's Republic of China: Continuation of... China: Final Results of Expedited Third Sunset Review of Antidumping Duty Order, 74 FR 55814 (October 29... Barium Chloride From China, 75 FR 33824 (June 15, 2010), and Barium Chloride from China (Inv. No....

  7. Predicting lower third molar eruption on panoramic radiographs after cephalometric comparison of profile and panoramic radiographs

    DEFF Research Database (Denmark)

    Begtrup, Anders; Grønastøð, Halldis Á; Christensen, Ib Jarle;

    2012-01-01

    Previous studies have suggested methods for predicting third molar tooth eruption radiographically. Still, this prediction is associated with uncertainty. The aim of the present study was to elucidate the association between cephalometric measurements on profile and panoramic radiographs and to f...

  8. Esophageal intramural pseudodiverticulosis characterized by barium esophagography: a case report

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-05-21

    Abstract Introduction Esophageal intramural pseudodiverticulosis is a rare condition characterized by the dilatation of the submucosal glands. Case presentation We present a case of esophageal intramural pseudodiverticulosis in a 72-year-old Caucasian man who presented with dysphagia and with a background history of alcohol abuse. An upper gastrointestinal endoscopy of our patient showed an esophageal stricture with abnormal mucosal appearances, but no malignant cells were seen at biopsy. Appearances on a barium esophagram were pathognomonic for esophageal intramural pseudodiverticulosis. Conclusion We demonstrate the enduring usefulness of barium esophagography in the characterization of abnormal mucosal appearances at endoscopy.

  9. Photoionization and Photoelectric Loading of Barium Ion Traps

    CERN Document Server

    Steele, A V; Churchill, L R; Griffin, P F

    2007-01-01

    Simple and effective techniques for loading barium ions into linear Paul traps are demonstrated. Two-step photoionization of neutral barium is achieved using a weak intercombination line (6s2 1S0 6s6p 3P1, 791 nm) followed by excitation above the ionization threshold using a nitrogen gas laser (337 nm). Isotopic selectivity is achieved by using a near Doppler-free geometry for excitation of the triplet 6s6p 3P1 state. Additionally, we report a particularly simple and efficient trap loading technique that employs an in-expensive UV epoxy curing lamp to generate photoelectrons.

  10. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  11. Giant colonic diverticulum: radiographic and MDCT characteristics.

    Science.gov (United States)

    Zeina, Abdel-Rauf; Mahamid, Ahmad; Nachtigal, Alicia; Ashkenazi, Itamar; Shapira-Rootman, Mika

    2015-12-01

    Giant colonic diverticulum (GCD), defined as a diverticulum larger than 4 cm, is a rare entity that is generally a manifestation of colonic diverticular disease. Because of its rarity and its variable and non-specific presentation, the diagnosis of GCD depends mainly on imaging findings. Knowledge of the spectrum of radiographic and CT features of the GCD is important in making the correct diagnosis and potentially preventing complications. This review focuses on imaging findings characteristic of GCD as well as its complications and radiographic mimics. Teaching points • Giant colonic diverticulum is a rare complication of diverticulosis.• The most common symptom is abdominal pain presenting in approximately 70 % of patients.• Diagnosis is based on imaging findings with plain abdominal radiographs and MDCT.• Treatment consists of en bloc resection of the diverticulum and affected adjacent colon.

  12. Pseudoprominent aorta: Radiographic findings and CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-05-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented.

  13. Lymphocytic adenohypophysitis: skull radiographs and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Saiwai, S.; Miyamoto, T. [Department of Radiology, Kobe Central Municipal Hospital, Hyogo (Japan); Inoue, Y.; Nemoto, Y.; Tashiro, T. [Department of Radiology, Osaka City University Medical School (Japan); Ishihara, T. [Department of Endocrinology, Kobe Central Municipal Hospital, Hyogo (Japan); Matsumoto, S. [Department of Neurosurgery, Kobe Central Municipal Hospital, Hyogo (Japan); Hakuba, A. [Department of Neurosurgery, Osaka City University Medical School, 1-5-7 Asahimachi, Abeno, Osaka, 545 (Japan)

    1998-02-01

    We report the skull radiograph, CT and MRI findings in three patients with lymphocytic adenohypophysitis mimicking pituitary adenoma. All cases were associated with pregnancy. CT demonstrated a pituitary mass but did not differentiate lymphocytic adenohypophysitis from pituitary adenoma. The skull radiographs showed either a normal sella turcica or minimal abnormalities; they did not show ballooning or destruction. The MRI appearances were distinctive: relatively low signal on T1-weighted images; preservation of the bright posterior pituitary lobe despite the presence of a relatively large pituitary mass, less common in macroadenomas; marked contrast enhancement compared with pituitary macroadenomas; and dural enhancement adjacent to a pituitary mass. (orig.) With 3 figs., 1 tab., 40 refs.

  14. Validation of a new radiographic protocol for Asian elephant feet and description of their radiographic anatomy.

    Science.gov (United States)

    Mumby, C; Bouts, T; Sambrook, L; Danika, S; Rees, E; Parry, A; Rendle, M; Masters, N; Weller, R

    2013-10-05

    Foot problems are extremely common in elephants and radiography is the only imaging method available but the radiographic anatomy has not been described in detail. The aims of this study were to develop a radiographic protocol for elephant feet using digital radiography, and to describe the normal radiographic anatomy of the Asian elephant front and hind foot. A total of fifteen cadaver foot specimens from captive Asian elephants were radiographed using a range of projections and exposures to determine the best radiographic technique. This was subsequently tested in live elephants in a free-contact setting. The normal radiographic anatomy of the Asian elephant front and hind foot was described with the use of three-dimensional models based on CT reconstructions. The projection angles that were found to be most useful were 65-70° for the front limb and 55-60° in the hind limb. The beam was centred 10-15 cm proximal to the cuticle in the front and 10-15 cm dorsal to the plantar edge of the sole in the hind foot depending on the size of the foot. The protocol developed can be used for larger-scale diagnostic investigations of captive elephant foot disorders, while the normal radiographic anatomy described can improve the diagnostic reliability of elephant feet radiography.

  15. A radiographic study of the position and shape of mental foramen in panoramic radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Karp Shik; Kim, Dong Youn; Sohn, Jeong Ick [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of); Bae, Yong Chul [Dept. of Oral Anatomy, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1997-02-15

    The purpose of this study was to evaluate the position and shape of mental foramen in panoramic radiographs. For this study, panoramic radiographs were obtained from the 200 adults and evaluated the position and shape of mental foramen. According to various positional changes in panoramic radiographs of the patients, the author also obtained panoramic radiographs from the 100 adults and then evaluated the positional and shape changes of mental foramen. The following results were obtained : 1. Shapes of mental foramen were observed elliptical (43.3%), round or oval (42.5%), unidentified (7.5%) and diffuse (6.7%) type in descending order of frequency. 2. Horizontal position of mental foramen were most frequently observed at the 2nd premolar area (54.2%), and area between the 1st premolar and 2nd premolar (43.1%), area between the 2nd premolar and 1st molar (2.7%), and at apex (9.7%), overlap with apex (1.9%), superior of apex (0.2%) in descending order of frequency. 4. According to various positional changes in panoramic radiographs of the patients, shape changes of mental foramen were more obviously observed at the forward 10 mm and chin down 10 degree positioned panoramic radiographs, And changes of horizontal and vertical position were observed in similar to compared with normal positioned panoramic radiographs.

  16. Barium Ferrite Films Grown By Pulsed Laser Ablation

    NARCIS (Netherlands)

    Lisfi, A.; Lodder, J.C.; Haan, de P.; Roesthuis, F.J.G.

    1998-01-01

    Abstract available only. It is known that barium ferrite (BaFe12019) can grow with perpendicular anisotropy on A1203 a single crystal substrate,' but also on an amorphous substrate by using a ZnO buffer.2 Because of its large magnetic anisotropy which can easily overcome the shape anisotropy of the

  17. Synthesis of Nanocrystalline Barium Ferrite in Ethanol/Water Media

    Institute of Scientific and Technical Information of China (English)

    M.Montazeri-Pour; A.Ataie

    2009-01-01

    Nanocrystalline particles of barium ferrite magnetic material have been prepared by co-precipitation route using aqueous and non-aqueous solutions of iron and barium chlorides with a Fe/Ba molar ratio of 11 and subsequent drying-annealing treatment. Water and ethanol/water mixture with volume ratio of 3:1 were used as solvents in the process. Coprecipitated powders were annealed at various temperatures for 1 h. FTIR (Fourier transform infrared spectroscopy), XRD (X-ray diffraction), DTA/TGA (differential thermal analy-sis/thermogravimetric analysis) and SEM (scanning electron microscopy) techniques were used to evaluate powder particle characteristics. DTA/TGA results confirmed by those obtained from XRD indicated that the formation of barium ferrite occurs in sample synthesized in ethanol/water solution at a relatively low temperature of 631℃. Nano-size particles of barium ferrite with mean particle size of almost 75 and 100 nm were observed in the SEM micrographs of the samples synthesized in ethanol/water solution after annealing at 700 and 800℃ for 1 h, respectively.

  18. Heavy ion recoil spectrometry of barium strontium titanate films

    Science.gov (United States)

    Stannard, W. B.; Johnston, P. N.; Walker, S. R.; Bubb, I. F.; Scott, J. F.; Cohen, D. D.; Dytlewski, N.; Martin, J. W.

    1995-05-01

    Thin films of barium strontium titanate have been analysed using heavy ion recoil spectrometry with 77 and 98 MeV 127I ions at the new heavy ion recoil facility at ANSTO, Lucas Heights. New calibration procedures have been developed for quantitative analysis. Energy spectra for each of the elements present reveal interdiffusion that was not previously known.

  19. Magnetoelastic coupling in epitaxial cobalt ferrite/barium titanate heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Gräfe, Joachim; Welke, Martin [Wilhelm-Ostwald-Institut für Physikalische und Theoretische Chemie, Universität Leipzig, Linnéstraße 2, 04103 Leipzig (Germany); Bern, Francis; Ziese, Michael [Institut für Experimentelle Physik II, Universität Leipzig, Linnéstraße 5, 04103 Leipzig (Germany); Denecke, Reinhard, E-mail: denecke@uni-leipzig.de [Wilhelm-Ostwald-Institut für Physikalische und Theoretische Chemie, Universität Leipzig, Linnéstraße 2, 04103 Leipzig (Germany)

    2013-08-15

    Ultra-thin cobalt ferrite films have been synthesised on ferroelectric barium titanate crystals. The cobalt ferrite films exhibit a magnetic response to strain induced by structural changes in the barium titanate substrate, suggesting a pathway to multiferroic coupling. These structural changes are achieved by heating through the phase transition temperatures of barium titanate. In addition the ferromagnetic signal of the substrate itself is taken into account, addressing the influence of impurities or defects in the substrate. The cobalt ferrite/barium titanate heterostructure is a suitable oxidic platform for future magnetoelectric applications with an established ferroelectric substrate and widely tuneable magnetic properties by changing the transition metal in the ferrite film. - Highlights: ► Ultra-thin CoFe{sub 2}O{sub 4} films grown on ferroelectric BaTiO{sub 3} crystals by PLD. ► Magnetic response to structural changes of BaTiO{sub 3} at transition temperatures. ► Significant magneto-elastic coupling of in-plane magnetisation in SQUID experiments. ► Clear distinction between contribution by BaTiO{sub 3} substrate and by CoFe{sub 2}O{sub 4} film.

  20. CNO and F abundances in the barium star HD 123396

    CERN Document Server

    Alves-Brito, Alan; Yong, David; Meléndez, Jorge; Vásquez, Sergio

    2011-01-01

    [Abridged] Barium stars are moderately rare chemically peculiar objects which are believed to be the result of the pollution of an otherwise normal star by material from an evolved companion on the asymptotic giant branch (AGB). We aim to derive carbon, nitrogen, oxygen, and fluorine abundances for the first time from infrared spectra of the barium red giant star HD 123396 to quantitatively test AGB nucleosynthesis models for producing barium stars via mass accretion. High-resolution and high S/N infrared spectra were obtained using the Phoenix spectrograph mounted at the Gemini South telescope. The abundances were obtained through spectrum synthesis of individual atomic and molecular lines, using the MOOG stellar line analysis program together with Kurucz's stellar atmosphere models. The analysis was classical, using 1D stellar models and spectral synthesis under the assumption of local thermodynamic equilibrium. We confirm that HD 123396 is a metal-deficient barium star ([Fe/H] = -1.05), with A(C) = 7.88, A...

  1. Excitation energies of barium oxide bands measured in flames

    NARCIS (Netherlands)

    Hurk, J. van der; Hollander, Tj.; Alkemade, C.T.J.

    1975-01-01

    Experiments are described that yield additional information about the excitation energy of visible barium oxide bands appearing in flames. Excitation energy differences are derived directly from the ratios of thermal band intensities as a function of temperature and agree with the value calculated f

  2. Intraabdominal panniculitis: clinical, radiographic, and CT features

    Energy Technology Data Exchange (ETDEWEB)

    Katz, M.E.; Heiken, J.P.; Glazer, H.S.; Lee, J.K.T.

    1985-08-01

    Intraabdominal panniculitis, also known as lipodystrophy, is an inflammatory condition of adipose tissue that may result in development of large masses containing necrotic fat (nodular intraabdominal panniculitis). Symptoms are secondary to inflammation or mass effect on adjacent organs. Barium studies may show nonspecific inflammatory changes and displacement of bowel loops. Computed tomography (CT) demonstrates inhomogeneous masses containing fat and soft tissue density. The diagnosis of intraabdominal panniculitis has seldom been made prospectively. However, the CT findings are characteristic and can aid in the evaluation and management of patients with this disease.

  3. Lateral cephalometric radiograph versus lateral nasopharyngeal radiograph for quantitative evaluation of nasopharyngeal airway space

    Directory of Open Access Journals (Sweden)

    Suelen Cristina da Costa Pereira

    2014-08-01

    Full Text Available OBJECTIVE: This study compared lateral radiographs of the nasopharynx (LN and lateral cephalometric radiographs (LC used to assess nasopharyngeal airway space in children. MATERIAL AND METHODS: One examiner measured the nasopharyngeal space of 15 oral breathing patients aged between 5 and 11 years old by using LN and LC. Both assessments were made twice with a 15-day interval in between. Intergroup comparison was performed with t-tests (P < 0.05. RESULTS: Comparison between LN and LC measurements showed no significant differences. CONCLUSION: Lateral cephalometric radiograph is an acceptable method used to assess nasopharyngeal airway space.

  4. Radiographic analysis of ameloblastoma: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chandramani More

    2012-01-01

    Conclusion: Radiographs are an important aid for the diagnosis of oral lesions of various types, especially those that involve bone. It is important for the practicing clinicians to know the salient features of ameloblastoma which are peculiar to the local population.

  5. Identifying murder victims with endodontic radiographs

    Science.gov (United States)

    Silva, Rhonan Ferreira; Franco, Ademir; Mendes, Solon Diego Santos Carvalho; Picoli, Fernando Fortes; Nunes, Fernando Gomes; Estrela, Carlos

    2016-01-01

    Endodontics is a special branch of dentistry constantly guided by imaging examinations. From a forensic scope, endodontics plays a valuable role providing solid antemortem (AM) radiographic evidence for comparison with postmortem findings in human identifications. This study illustrates the interface between endodontics and forensic odontology describing three cases of human identification based on radiographic endodontic records. From 2009 to 2012, three unknown male victims of murder were examined in a local Brazilian medico-legal institute to retrieve identity and potential cause of death. Specifically, when asked for AM data, a relative of the three victims provided periapical radiographs of endodontic treatments. Based on that, forensic dentists reproduced the same imaging acquisition techniques obtaining similar periapical radiographs, enabling a comparative dental identification. All the victims were positively identified based on patterns of dental morphology and treatment intervention. This study draws the attention of general and forensic dentists highlight the importance of properly recording dental treatments and searching for evidence in AM endodontic data, respectively. PMID:28123272

  6. Age estimation using intraoral periapical radiographs

    Directory of Open Access Journals (Sweden)

    Pooja S Rajpal

    2016-01-01

    Full Text Available Context: Changes in the size of dental pulp caused by the apposition of secondary dentin and occlusal wear are morphometric parameters for estimating age. Aim: To estimate the accuracy of age evaluation by Kvaal's method and the effect of occlusal wear on age using digital intraoral periapical radiographs in a subset of the Indian population. Materials and Methods: A total of 300 teeth were radiographically evaluated using intraoral periapical digital radiographs from 50 adult patients. A few modifications were made in the design of the study compared to the original Kvaal's method. The radiographs of three teeth from each jaw were taken and morphometric measurements in ratios were analyzed, which included the pulp length to tooth length (X1, pulp length to root length (X2, pulp width to root widths at three defined levels (X3, and tooth length to root length (X4. Statistical Analysis: The Pearson product-moment correlation coefficient (PCC between age and the morphological variables showed that among them X1, X2, and X3were statistically significant but not the tooth root length ratio (X4. Conclusions: The ratios X1, X2, and X3were good indicators of age and hence a multiple linear regression model for age estimation was derived using these three variables. However, it was found that X4was not a good indicator of age estimation in said population.

  7. Radiographic evaluation and assessment of paragangliomas.

    Science.gov (United States)

    Lustrin, E S; Palestro, C; Vaheesan, K

    2001-10-01

    Radiographic imaging plays an important role in the diagnosis and treatment of paragangliomas. Diagnosis and treatment should be performed as a team effort, with all the involved disciplines working together to provide the best possible individualized work-up and treatment plan for the patient.

  8. Predicting lower third molar eruption on panoramic radiographs after cephalometric comparison of profile and panoramic radiographs.

    Science.gov (United States)

    Begtrup, Anders; Grønastøð, Halldis Á; Christensen, Ib Jarle; Kjær, Inger

    2013-08-01

    Previous studies have suggested methods for predicting third molar tooth eruption radiographically. Still, this prediction is associated with uncertainty. The aim of the present study was to elucidate the association between cephalometric measurements on profile and panoramic radiographs and to find a simple and reliable method for predicting the eruption of the mandibular third molar by measurements on panoramic radiographs. The material consisted of profile and panoramic radiographs, taken before orthodontic treatment, of 30 males and 23 females (median age 22, range 18-48 years), with no known diseases. Cephalometric measurements on panoramic and profile radiographs were performed and compared, i.e. the size of the gonial angle and sagittal distance from the alveolar margin between the mandibular central incisors to the anterior border of the mandibular ramus. Furthermore, the mesiodistal width of the second molar was measured. Statistical methods included analysis of method error. The probability of eruption was modelled using logistic regression analysis. Correlation was observed between all measurements on profile and panoramic radiographs. The skeletal variable expressing the length from the ramus to the incisors (olr-id) showed a statistically significant correlation. By combining this length with the mesiodistal width of the lower second molar, the prediction of eruption of the lower third molar was strengthened. A new formula for calculating the probability of eruption of the mandibular third molar was made and a graph constructed for easy assessment. In conclusion, a simple method for predicting the eruption of the third molar is presented.

  9. 10 CFR 34.46 - Supervision of radiographers' assistants.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Supervision of radiographers' assistants. 34.46 Section 34... REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.46 Supervision of... personal supervision of a radiographer. The personal supervision must include: (a) The...

  10. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic head holder. 892.1920 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1920 Radiographic head holder. (a) Identification. A radiographic head holder is a device intended to position the patient's head during...

  11. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used...

  12. Effect of radiographic contrast agents on leukocyte metabolic response

    Energy Technology Data Exchange (ETDEWEB)

    Hernanz-Schulman, M. [Dept. of Pediatric Radiology, Vanderbilt Children' s Hospital, Nashville, TN (United States); Vanholder, R.; Waterloos, M.A. [Dept. of Internal Medicine, Nephrology Section, University Hospital, Gent (Belgium); Hakim, R.; Schulman, G. [Department of Nephrology, Vanderbilt University Medical Center, Nashville, TN (United States)

    2000-06-01

    Barium, at clinical dilutions, causes a significant increase of baseline ''resting state'' phagocytic activity, which in turn leads to significant blunting of subsequent response to phagocytic challenge and adversely affects the response to all bacteria tested. There is no baseline activation of leukocytes by the water-soluble media, although there was some inhibition (rather than activation) of leukocyte metabolic activity. The effect of the water-soluble media in bacteria was more complex (although inhibition is minor compared to barium). Our data demonstrate that barium is a significat activator of phagocytic cells, which results in deactivation of phagocytic response when challenged; these dsata serve to explain the enhanced adverse effect of barium in cased of fecal peritonitis. (orig.)

  13. Design, testing, fabrication and launch support of a liquid chemical barium release payload (utilizing the liquid fluorine-barium salt/hydrazine system)

    Science.gov (United States)

    Stokes, C. S.; Smith, E. W.; Murphy, W. J.

    1972-01-01

    A payload was designed which included a cryogenic oxidizer tank, a fuel tank, and burner section. Release of 30 lb of chemicals was planned to occur in 2 seconds at the optimum oxidizer to fuel ratio. The chemicals consisted of 17 lb of liquid fluorine oxidizer and 13 lb of hydrazine-barium salt fuel mixture. The fuel mixture was 17% barium chloride, 16% barium nitrate, and 67% hydrazine, and contained 2.6 lb of available barium. Two significant problem areas were resolved during the program: explosive valve development and burner operation. The release payload was flight tested, from Wallops Island, Virginia. The release took place at an altitude of approximately 260 km. The release produced a luminous cloud which expanded very rapidly, disappearing to the human eye in about 20 seconds. Barium ion concentration slowly increased over a wide area of sky until measurements were discontinued at sunrise (about 30 minutes).

  14. Mediastinal hemorrhage: An evaluation of radiographic manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Woodring, J.H.; Loh, F.K.; Kryscio, R.J.

    1984-04-01

    Eleven common radiographic signs of mediastinal hemorrhage were evaluated by two observers for the following three patient groups: normal subjects, patients with mediastinal hemorrhage and no arterial injury, and patients with major thoracic arterial injury. Supine chest radiographs were studied in all cases. Four major conclusions can be made based upon these finding. M/C ratio (mediastinal width to chest width), tracheal deviation, left hemothorax, paraspinal line widening, and aorto-pulmonary window opacification do not reliably separate these three groups of patients. The diagnosis of mediastinal hemorrhage may be made if the aortic contour is abnormal or if one of the following signs is positive: abnormal mediastinal width, apical cap, widening of the right paratracheal stripe, or deviation of the nasogastric tube. Due to interobserver variation, there is good agreement between observers for the following four signs only: transverse mediastinal width, tracheal deviation, nasogastric tube deviation, nasogastric tube deviation, and right paratracheal stripe widening.

  15. RADIOGRAPHIC EXAMINATION OF TEMPOROMANDIBULAR DISORDERS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Heru Suryonegoro

    2015-06-01

    Full Text Available The temporomandibular joint has a very important role in the stomatognathic system. Its main function is for the opening and closing movement, mastication, and speech. It is located anterior to the ear. The temporomandibular joint connects maxilla and mandible through the articular fossa, hence the slightest change that happens would cause serious matters such as pain, exiting, speech disorder, difficulty in opening and closing movement, headache, and even trismus. In a child or an adolescent, the symptoms are often vague; everything is interpreted as “pain”. This is probably why temporomandibular disorder are often undetected by dentists. Therefore, patience and accuracy is needed to determine the actual disorder through means of clinical and radiographic examination. The radiographic examination suitable for child is the transcranial projection. This projection is believed to be more accurate amongst other projection for child patients.

  16. An enlarged sella turcica on cephalometric radiograph.

    Science.gov (United States)

    Chang, H-P; Tseng, Y-C; Chou, T-M

    2005-09-01

    A 28-year-old male presented to the Orthodontic clinic for correction of his anterior crossbite due to mandibular prognathism as a result of pituitary adenoma with acromegaly. A radiographic cephalometric analysis and clinical orthodontic examination were made. This article describes in detail the methods of correcting the magnification of cephalometric linear measurements in sellar dimensions (length, depth and width) from lateral and posteroanterior cephalograms. Cephalometric findings revealed that the sella enlarged in all its dimensions with a deepening of the floor in this acromegalic case. We discuss the radiographic diagnosis of an enlarged sella turcica in intrasellar tumours and also emphasise the dentist's important role in the initial diagnosis of pituitary adenoma cases.

  17. Electromagnetic properties of carbon black and barium titanate composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Wang Guiqin [School of Material Science and Engineering, Dalian University of Technology, Dalian 116023 (China)], E-mail: c2b2chen@163.com; Chen Xiaodong; Duan Yuping; Liu Shunhua [School of Material Science and Engineering, Dalian University of Technology, Dalian 116023 (China)

    2008-04-24

    Nanocrystalline carbon black/barium titanate compound particle (CP) was synthesized by sol-gel method. The phase structure and morphology of compound particle were investigated by X-ray diffraction (XRD), transmission electron microscope (TEM) and Raman spectrum measurements, the electroconductivity was test by trielectrode arrangement and the precursor powder was followed by differential scanning calorimetric measurements (DSC) and thermal gravimetric analysis (TGA). In addition, the complex relative permittivity and permeability of compound particle were investigated by reflection method. The compound particle/epoxide resin composite (CP/EP) with different contents of CP were measured. The results show barium titanate crystal is tetragonal phase and its grain is oval shape with 80-100 nm which was coated by carbon black film. As electromagnetic (EM) complex permittivity, permeability and reflection loss (RL) shown that the compound particle is mainly a kind of electric and dielectric lossy materials and exhibits excellent microwave absorption performance in the X- and Ku-bands.

  18. HYBRID AND CHARACTERISTIC OF POLYANILINE- BARIUM TITANATE NANOCOMPOSITE PARTICLES

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Polyaniline-barium titanate (PAn-BaTiO3) ultrafine composite particles were prepared by the oxidative polymerization of aniline with H2O2 while barium titanate nanoparticles were synthesized with a sol-gel method. The infrared spectrogram shows that the polymerization of PAn in the hybrid process of PAn-BaTiO3 is similar with the polymeric process of pure aniline, and there is interaction of PAn and BaTiO3 in the PAn-BaTiO3. SEM and TEM results show that the average diameter of the composite particles is 1.50 μm and the diameters of BaTiO3 nanoparticles are 5-15 nm in the composite particle. The electrical conductivity of the ultrafine composite particles is transformable from 100 to 10-11S/cm by equilibrium doping or dedoping method using various concentration of HCl or NaOH solutions.

  19. The crystal growth of barium flouride in aqueous solution

    Science.gov (United States)

    Barone, J. P.; Svrjcek, D.; Nancollas, G. H.

    1983-06-01

    The kinetics of growth of barium flouride seed crystals were investigated in aqueous solution at 25°C using a constant composition method, in which the supersaturation and ionic strength were maintained constant by the addition of titrants consisting of barium nitrate and potassium flouride solutions. The rates of reaction, studied over a range of supersaturation (σ ≈ 0.4 to 1.0), were interpreted in terms of crystal growth models. A spiral growth mechanism best describes the data, and scanning electron microscopy indicates a three-dimensional growth. In the presence of inorganic additives such as phosphate, however, induction periods precede a morphological two-dimensional crystallization. Coulter Counter results show little crystal agglomeration.

  20. Particularities of Radiation Defect Formation in Ceramic Barium Cerate

    Science.gov (United States)

    Khromushin, I. V.; Aksenova, T. I.; Tuseev, T.; Munasbaeva, K. K.; Ermolaev, Yu V.; Ermolaev, V. N.; Seitov, A. S.

    2015-04-01

    The effects of irradiation with electrons, ions of noble gases (Ne, Ar, Kr) and oxygen on the structure and properties of neodymium-doped barium cerate have been studied using the methods of X-ray diffraction analysis, scanning electron and atomic force microscopy, thermal desorption spectroscopy. It was shown that irradiation by low-energy ions of noble gases stimulates the blistering processes on the sample surface, while the high-energy ions contribute to formation of the structures on the irradiated surface that resemble the various stages of spherulitegrowth. The similar structures were not observed in the case of irradiation with high-energy oxygen ions. According to the data on thermal desorption of water and oxygen molecules from the irradiated barium cerate it was supposed that irradiation by the noble gas ions promotes neodymium oxidation state change. It was noticed that the electron irradiation leads to the formation of the nano-sized acicular structures on the cerate surface.

  1. Barium titanate nanoparticles: promising multitasking vectors in nanomedicine

    Science.gov (United States)

    Graziana Genchi, Giada; Marino, Attilio; Rocca, Antonella; Mattoli, Virgilio; Ciofani, Gianni

    2016-06-01

    Ceramic materials based on perovskite-like oxides have traditionally been the object of intense interest for their applicability in electrical and electronic devices. Due to its high dielectric constant and piezoelectric features, barium titanate (BaTiO3) is probably one of the most studied compounds of this family. Recently, an increasing number of studies have been focused on the exploitation of barium titanate nanoparticles (BTNPs) in the biomedical field, owing to the high biocompatibility of BTNPs and their peculiar non-linear optical properties that have encouraged their use as nanocarriers for drug delivery and as label-free imaging probes. In this review, we summarize all the recent findings about these ‘smart’ nanoparticles, including the latest, most promising potential as nanotransducers for cell stimulation.

  2. Stark spectrum of barium in highly excited Rydberg states

    Institute of Scientific and Technical Information of China (English)

    Yang Hai-Feng; Gao Wei; Cheng Hong; Liu Xiao-Jun; Liu Hong-Ping

    2013-01-01

    We present observations of Stark spectra of barium in highly excited Rydberg states in the energy region around n =35.The one-photon excitation concerns the π transition.The observed Stark spectra at electric fields ranging from 0 to 60 V·cm-1 are well explained by the diagonalization of the Hamiltonian incorporating the core effects.From the Stark maps,the anti-crossings between energy levels are identified experimentally and theoretically.The time of flight spectra at the specified Stark states are recorded,where the deceleration and acceleration of barium atoms are observed.This is very consistent with the prediction derived from the Stark maps from the point of view of energy conservation.

  3. Iterative Reconstruction of Coded Source Neutron Radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Bingham, Philip R [ORNL; Gregor, Jens [University of Tennessee, Knoxville (UTK)

    2012-01-01

    Use of a coded source facilitates high-resolution neutron imaging but requires that the radiographic data be deconvolved. In this paper, we compare direct deconvolution with two different iterative algorithms, namely, one based on direct deconvolution embedded in an MLE-like framework and one based on a geometric model of the neutron beam and a least squares formulation of the inverse imaging problem.

  4. Video enhancement of dental radiographic films

    Energy Technology Data Exchange (ETDEWEB)

    Van Dis, M.L.; Beck, F.M.; Miles, D.A. (Ohio State Univ., Columbus (USA))

    1989-08-01

    A prototype video image display system, a real-time analog enhancer (RAE), was compared to conventional viewing conditions with the use of nonscreen dental films. When medium optical density films were evaluated, there was no significant difference in the number of radiographic details detected. Conventional viewing conditions allowed perception of more details when dark films were evaluated; however, the RAE unit allowed the perception of more details when light films were viewed.

  5. Acute barium intoxication following ingestion of soap water solution

    Directory of Open Access Journals (Sweden)

    Nandita Joshi

    2012-01-01

    Full Text Available We present a rare case in which a young girl ingested a solution of a hair-removing soap. The ingestion resulted in profound hypokalemia and severe acidosis leading to flaccid paralysis, respiratory arrest and ventricular arrhythmias. Ultimately the patient made complete recovery. The soapwas found to contain barium sulfide. The degree of paralysis and acidosis appeared to be directly related to serum potassium levels.

  6. Complex Impedance Studies of Optically Excited Strontium Barium Niobate

    Science.gov (United States)

    2007-11-02

    has a tetragonal tungsten - bronze structure. The unit cell for this structure, illustrated below in Fig. 2.1, consists of ten oxygen octahedra joined...4 Kittel, pp. 373-374. 5 P. B. Jamieson, et al, “Ferroelectric Tungsten Bronze -Type Crystal Structures. I. Barium Strontium Niobate...Oxford, 1987). 2. C. Kittel, Introduction to Solid State Physics, (Wiley, New York, 1986). 3. P. B. Jamieson, et al, “Ferroelectric Tungsten

  7. Nosocomial Legionnaires’ Disease: Clinical and Radiographic Patterns

    Directory of Open Access Journals (Sweden)

    Thomas J Marrie

    1992-01-01

    Full Text Available From 1981 to 1991, 55 patients (33 males, 22 females, mean age 58.6 years with nosocomial Legionnaires’ disease were studied. The mortality rate was 64%. One-half of the patients developed nosocomial Legionnaires’ disease within three weeks of admission. A surprising clinical feature was the low rate of findings of consolidation on physical examination, despite the fact that 52% of patients had this finding on chest radiograph. More than one-half of patients had pre-existing lung disease, rendering a radiographic diagnosis of pneumonia due to Legionella pneumophila impossible in 16% of cases despite microbiological confirmation. Nineteen per cent of patients who had blood cultures done had a pathogen other than L pneumophila isolated, suggesting dual infection in at least some of the patients. When the clinical and radiographic findings were combined it was noted that 40% of patients had one of three patterns suggestive of nosocomial Legionnaires’ disease: rapidly progressive pneumonia, lobar opacity and multiple peripheral opacities. However, in 60% of patients there were no distinctive features.

  8. Elongated Styloid Process - A Radiographic Study

    Directory of Open Access Journals (Sweden)

    Vajendra Joshi

    2007-01-01

    Full Text Available Eagle′s syndrome, also known as elongated styloid process syndrome, is a condition that may be the source of craniofacial and cervical pain. The styloid process is a slender bony projection arising from the lower surface of the petrous portion of the temporal bone. It has been estimated that between 2% to 28% of the general adult population has radiographic evidence of elongated styloid process. In adults, the mean radiographic length of the styloid process is 20 to 30 mm and its tip is located between the external and internal carotid arteries, just lateral to the tonsillar fossa. This study was done to evaluate the elongation of the styloid process and/or ligament ossification by using panoramic radiographs. Both ossification of stylohyoid and stylomandibular ligaments and truly elongated styloid process were defined as elongated styloid process. Elongated styloid processes should be kept in mind when the clinician is faced with oropharyngeal/ maxillary pain originating from impacted or unerupted third molars or dental caries.

  9. Radiographic adenoid evaluation - suggestion of referral parameters

    Directory of Open Access Journals (Sweden)

    Murilo F.N. Feres

    2014-06-01

    Full Text Available OBJECTIVE: this study aimed to evaluate the usefulness of current radiographic measurements, which were originally conceived to evaluate adenoid hypertrophy, as potential referral parameters. METHODS: children aged from 4 to 14 years, of both genders, who presented nasal obstruction complaints, were subjected to cavum radiography. Radiographic examinations (n = 120 were evaluated according to categorical and quantitative parameters, and data were compared to gold-standard videonasopharyngoscopic examination, regarding accuracy (sensitivity, negative predictive value, specificity, and positive predictive value. RESULTS: radiographic grading systems presented low sensitivity for the identification of patients with two-thirds choanal space obstruction. However, some of these parameters presented relatively high specificity rates when three-quarters adenoid obstruction was the threshold of interest. Amongst the quantitative variables, a mathematical model was found to be more suitable for identifying patients with more than two-thirds obstruction. CONCLUSION: this model was shown to be potentially useful as a screening tool to include patients with, at least, two-thirds adenoid obstruction. Moreover, one of the categorical parameters was demonstrated to be relatively more useful, as well as a potentially safer assessment tool to exclude patients with less than three-quarters obstruction, to be indicated for adenoidectomy.

  10. Barium thiolates and selenolates: syntheses and structural principles.

    Science.gov (United States)

    Ruhlandt-Senge, K; Englich, U

    2000-11-17

    The synthesis and structural characterization of a family of barium thiolates and selenolates is described. The thiolates were synthesized by metallation of thiols, the selenolates by reductive insertion of the metal into the selenium-selenium bond of diorganodiselenides. Both reaction sequences were carried out by using barium metal dissolved in ammonia; this afforded barium thiolates and selenolates in good yield and purity. The structural principles displayed in the target compounds span a wide range of solid-state formulations, including monomeric and dimeric species, and separated ion triples, namely [Ba(thf)4(SMes*)2] (1; Mes* = 2,4,6-tBU3C6H2), [Ba(thf)4(SeMes*)2] (2), [Ba([18]crown-6)(hmpa)2][(SeMes*)2] (3), the dimeric [(Ba(py)3(thf)(SeTrip)2)2] (4; py = pyridine, Trip = 2,4.6-iPr3C6H2), and [Ba([18]crown-6)(SeTrip)2] (5). The full range of association modes is completed by [Ba([18]crown-6)(hmpa)SMes*][SMes*] (6) communicated earlier by this group. In the solid state, this compound displays an intermediate ion coordination mode: one anion is bound to the metal, while the second one is unassociated. Together these compounds provide structural information about all three different association modes for alkaline earth metal derivatives. This collection of structural data allows important conclusions about the influence of solvation and ligation on structural trends.

  11. Microwave-hydrothermal synthesis of barium strontium titanate nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Simoes, A.Z., E-mail: alezipo@yahoo.co [Universidade Federal de Itajuba- Unifei - Campus Itabira, Rua Sao Paulo, 377, Bairro, Amazonas, CEP 35900-37, Itabira, MG (Brazil); Universidade Estadual Paulista- Unesp - Faculdade de Engenharia de Guaratingueta, Av. Dr. Ariberto Pereira da Cunha, 333, Bairro Pedregulho, CEP 12516-410 Guaratingueta, SP (Brazil); Moura, F.; Onofre, T.B. [Universidade Federal de Itajuba- Unifei - Campus Itabira, Rua Sao Paulo, 377, Bairro, Amazonas, CEP 35900-37, Itabira, MG (Brazil); Ramirez, M.A.; Varela, J.A.; Longo, E. [Laboratorio Interdisciplinar em Ceramica (LIEC), Departamento de Fisico-Quimica, Instituto de Quimica, UNESP, CEP 14800-900, Araraquara, SP (Brazil)

    2010-10-22

    Research highlights: {yields} Barium strontium titanate nanoparticles were obtained by the Hydrothemal microwave technique (HTMW) {yields} This is a genuine technique to obtain nanoparticles at low temperature and short times {yields} Barium strontium titanate free of carbonates with tetragonal structure was grown at 130 {sup o}C. - Abstract: Hydrothermal-microwave method (HTMW) was used to synthesize crystalline barium strontium titanate (Ba{sub 0.8}Sr{sub 0.2}TiO{sub 3}) nanoparticles (BST) in the temperature range of 100-130 {sup o}C. The crystallization of BST with tetragonal structure was reached at all the synthesis temperatures along with the formation of BaCO{sub 3} as a minor impurity at lower syntheses temperatures. Typical FT-IR spectra for tetragonal (BST) nanoparticles presented well defined bands, indicating a substantial short-range order in the system. TG-DTA analyses confirmed the presence of lattice OH- groups, commonly found in materials obtained by HTMW process. FE/SEM revealed that lower syntheses temperatures led to a morphology that consisted of uniform grains while higher syntheses temperature consisted of big grains isolated and embedded in a matrix of small grains. TEM has shown BST nanoparticles with diameters between 40 and 80 nm. These results show that the HTMW synthesis route is rapid, cost effective, and could serve as an alternative to obtain BST nanoparticles.

  12. The forensic radiographer: a new member in the medicolegal team.

    Science.gov (United States)

    Schneider, Benjamin; Chevallier, Christine; Dominguez, Alejandro; Bruguier, Christine; Elandoy, Cristèle; Mangin, Patrice; Grabherr, Silke

    2012-03-01

    Multidetector computed tomography is becoming more widespread in forensic medicine. In most services, autopsy assistants perform the radiological examination. We introduced professional radiographers into the legal medicine service and hypothesized they would also be able to take over duties currently reserved for other specialists. The aims of this study were to evaluate if radiographers could be trained as "forensic radiographers" by (1) integrating graduated medical radiographers into the legal medicine service, (2) investigating the advantages of this collaboration, and (3) defining the duties of the forensic radiographers.The study was performed prospectively on a group of 8 recruited radiographers who underwent a testing period with special training. They learned the basics of medicolegal case treatment, the autonomous execution of postmortem computed tomography angiography, and postprocessing of data. Seven of 8 radiographers finished the training and were integrated into our service. Although all radiographers were able to fulfill the duties demanded after the training period, some radiographers could not enter or complete the program because they were unable to work with dead bodies.Our study presents the advantages of integrating radiographers into the medicolegal team and proposes how to train the forensic radiographers. In addition, the duties and responsibilities of these new specialists are defined.

  13. Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO

    OpenAIRE

    Mong, B.; Cook, S; Walton, T.; Chambers, C.; Craycraft, A.; Benitez-Medina, C.; Hall, K.; Fairbank Jr., W.; Albert, J. B.; Auty, D. J.; Barbeau, P. S.; Basque, V.; Beck, D.; Breidenbach, M.; Brunner, T.

    2014-01-01

    Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fl...

  14. Preparation of nanosized barium zirconate powder by precipitation in aqueous solution

    OpenAIRE

    Boschini, Frédéric; Guillaume, Bernard; Rulmont, André; Cloots, Rudi

    2004-01-01

    Several ways were explored to synthesize barium zirconate by soft chemistry methods in aqueous solution. In the first method the synthesis of barium zirconate was initiated by urea decomposition, through an homogeneous precipitation of barium and zirconium salts followed by a "low temperature" thermal treatment. The kinetic of the reaction and the optimum urea/cation ratio have been determined by means of X-ray diffraction and Inductive Coupled Plasma analyses. It has been demonstrated that a...

  15. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Weitang; Zhang, Zhiyong; Liu, Jinbo; Li, Zhen; Song, Junmin; Wu, Changcai [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China); Wang, Guixian, E-mail: guixianwang@hotmail.com [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China)

    2012-09-15

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation.

  16. Sponge-associated bacteria mineralize arsenic and barium on intracellular vesicles

    Science.gov (United States)

    Keren, Ray; Mayzel, Boaz; Lavy, Adi; Polishchuk, Iryna; Levy, Davide; Fakra, Sirine C.; Pokroy, Boaz; Ilan, Micha

    2017-01-01

    Arsenic and barium are ubiquitous environmental toxins that accumulate in higher trophic-level organisms. Whereas metazoans have detoxifying organs to cope with toxic metals, sponges lack organs but harbour a symbiotic microbiome performing various functions. Here we examine the potential roles of microorganisms in arsenic and barium cycles in the sponge Theonella swinhoei, known to accumulate high levels of these metals. We show that a single sponge symbiotic bacterium, Entotheonella sp., constitutes the arsenic- and barium-accumulating entity within the host. These bacteria mineralize both arsenic and barium on intracellular vesicles. Our results indicate that Entotheonella sp. may act as a detoxifying organ for its host. PMID:28233852

  17. Effects of powdered versus liquid barium on the viscosity of fluids used in modified swallow studies

    Energy Technology Data Exchange (ETDEWEB)

    Baron, J.; Alexander, T. [Univ. of Alberta, Dept. of Radiology, Edmonton, Alberta (Canada)

    2003-06-01

    To determine if the viscosity of thickened juice mixtures used in modified barium swallow studies significantly changes with the addition of powdered barium. We also describe a test formulation created using liquid barium, which has a negligible effect on juice viscosity. The viscosities of water and standardized honey- and nectar-consistency juices mixed with different amounts of powdered barium were measured by timing the laminar flow of a given initial hydrostatic head of fluid under gravity though an orifice of fixed diameter. Standardized juices were then mixed with a liquid formulation of barium and with measured quantities of water to produce viscosities that more closely equated with those of the standardized juices. With the addition of powdered barium, viscosity increased in all fluids, most markedly with the nectar-consistency juice. Liquid barium formulations maintained the viscosities of the original thickened juices. Rendering juices radio-opaque with barium powder results in dramatic increases in the viscosity of the resulting mixture and compromises diagnostic accuracy. Liquid barium preparations have the advantage that they can be rapidly and accurately dispensed by syringe, and their use does not significantly increase the viscosity of the preparation. (author)

  18. BARIUM SULPHATE ABSORPTION AND THE SERUM DIAGNOSIS OF SYPHILIS.

    Science.gov (United States)

    Noguchi, H; Bronfenbrenner, J

    1911-02-01

    The so-called syphilitic antibodies can be removed from a serum by means of absorption with barium sulphate. The removal is due either to an adsorption or a mechanical absorption. The activity of the syphilitic antibodies is thereby unimpaired. The readiness with which the absorption is accomplished with barium sulphate varies considerably with different syphilitic sera. That barium sulphate exerts the same absorbing effect upon non-syphilitic serum components is made evident by the interfering property which the latter manifest in the absorption experiment of the syphilitic antibodies. The selective removal of the serum components, other than the syphilitic antibodies, by means of barium sulphate absorption is, therefore, impossible. On the other hand, a partial removal of these components, with but little removal of the syphilitic antibodies, may be effected when the content of a given serum is poor in syphilitic antibodies and comparatively rich in the indifferent serum components. But this is impossible if the conditions are reversed. The main reasons why some negative syphilitic sera may be so modified by the barium sulphate treatment as to give positive reactions, are explained below, but these apply only to those methods in which inactivated serum is employed. The inactivation reduces the antibody content to about one-fourth to one-fifth of the original. When the serum is very rich in antibodies, this does not affect the result of the fixation test. But when the amount of the antibodies is small, the process of inactivation creates conditions quite unexpected. It may produce such a condition that a given amount of the serum contains, after inactivation, only one or two antibody units, while the other serum components remain undiminished. Here one must not lose sight of the vital fact that these apparently indifferent serum constituents are not at all indifferent in the fixation processes. They may possess affinities which are similar to those of complement

  19. 铝酸钡与氢氧化钡脱硫过程比较%Comparison of Barium Aluminate and Barium Hydroxide Desulfurization Process

    Institute of Scientific and Technical Information of China (English)

    张念炳; 黎志英; 丁彤

    2012-01-01

    The seed precipitation liquor was desulfurized with barium aluminate and barium hydroxide respectively. The desulfurization slag was characterized by XRD analysis, and the desulfurization process was compared. The results show that barium hydroxide exceeds barium aluminate with better desulfurization in terms of effect, speed and duration. In the desulfurization process with barium aluminate, 2BaO · Al2O3 · 5H2O is firstly produced in the reaction of barium aluminate with alkali, and then it reacts with sodium sulfate and sodium carbonate. To compare, Ba(OH)2 · 8H2O directly reacts with sodium sulfate and sodium carbonate in the desulfurization process with barium hydroxide. Both of desulfurization reaction processes can be described with "shrinking core model".%用铝酸钡和氢氧化钡对种分母液进行脱硫试验,对脱硫渣进行XRD分析,并比较脱硫过程.结果表明,氢氧化钡的脱硫效果更好,脱硫完成时间更短,速率更快;铝酸钡先与碱液反应生成2BaO·Al2O3·5H2O,再与硫碱和碳碱反应,而氢氧化钡直接与硫碱和碳碱反应,脱硫过程均可用未反应核模型描述.

  20. Normal radiographic findings. 4. act. ed.; Roentgennormalbefunde

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, T.B. [Gemeinschaftspraxis fuer Radiologie und Nuklearmedizin, Dillingen (Germany)

    2003-07-01

    This book can serve the reader in three ways: First, it presents normal findings for all radiographic techniques including KM. Important data which are criteria of normal findings are indicated directly in the pictures and are also explained in full text and in summary form. Secondly, it teaches the systematics of interpreting a picture - how to look at it, what structures to regard in what order, and for what to look in particular. Checklists are presented in each case. Thirdly, findings are formulated in accordance with the image analysis procedure. All criteria of normal findings are defined in these formulations, which make them an important didactic element. (orig.)

  1. Chest radiographic manifestations of scrub typhus

    Directory of Open Access Journals (Sweden)

    KPP Abhilash

    2016-01-01

    Full Text Available Background and Rationale: Respiratory system involvement in scrub typhus is seen in 20–72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Materials and Methods: Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. Results: The study cohort contained 398 patients. Common presenting complaints included fever (100%, generalized myalgia (83%, headache (65%, dyspnea (54%, cough (24.3%, and altered sensorium (14%. Almost half of the patients (49.4% had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%, acute respiratory distress syndrome (14%, airspace opacity (10.5%, reticulonodular opacities (10.3%, peribronchial thickening (5.8%, and pulmonary edema (2%. Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89–33.16, invasive ventilation (OR: 18.07; 95% CI: 6.42–50.88, inotropes (OR: 8.76; 95% CI: 4.35–17.62, higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001, and higher mortality (OR: 4.63; 95% CI: 1.54–13.85. Conclusion: Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  2. Radiographic analysis of temporomandibular joint arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1984-11-15

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  3. Revolutionizing radiographic diagnostic accuracy in periodontics

    Directory of Open Access Journals (Sweden)

    Brijesh Sharma

    2016-01-01

    Full Text Available Effective diagnostic accuracy has in some way been the missing link between periodontal diagnosis and treatment. Most of the clinicians rely on the conventional two-dimensional (2D radiographs. But being a 2D image, it has its own limitations. 2D images at times can give an incomplete picture about the severity or type of disease and can further affect the treatment plan. Cone beam computed tomography (CBCT has a better potential for detecting periodontal bone defects with accuracy. The purpose here is to describe how CBCT imaging is beneficial in accurate diagnosis and will lead to a precise treatment plan.

  4. INCIDENTAL RADIOGRAPHIC FINDINGS AND THEIR RESTORAT IVE IMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Sridevi

    2012-09-01

    Full Text Available ABSTRACT: Radiographs are an irreplaceable diagnostic tool, es pecially in dealing with dentofacial hard tissues. Guidelines like the ALARA require professionals to limit the number of radiographs prescribed to patient, thereby minimizing radiation dose. On the other hand, for prosthetic evaluation, a latest radiograph has the po tential to uncover new findings that can alter the treatment planning sequence or affect the outcome of the planned treatment. This review article discusses ten such radiographs. The s ignificant findings in each radiograph have been highlighted and treatment protocols tailored t o the same. The aim of this article is to help the reader adopt a meticulous approach and a keen eye for detecting problems, and emphasizes the efficacy of radiographs in patient evaluation for restorative care

  5. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    OpenAIRE

    2015-01-01

    Purpose This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radio...

  6. Subperiosteal osteoid osteoma: radiographic and pathologic manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Shankman, S. [Department of Radiology, Hospital for Joint Diseases/OI, 301 East 17th Street, New York, NY 10003 (United States); Desai, P. [Department of Pathology, Hospital for Joint Diseases/OI, 301 East 17th Street, New York, NY 10003 (United States); Beltran, J. [Department of Radiology, Hospital for Joint Diseases/OI, 301 East 17th Street, New York, NY 10003 (United States)

    1997-08-01

    Objective.To demonstrate the radiologic and pathologic manifestations of osteoid osteoma arising beneath the periosteum, on the surface of the bone. Design. One hundred and sixty osteoid osteomas were seen over a 30-year period. The radiologic, pathologic and operative findings of those that were subperiosteal were reviewed. Patients. Eleven patients with subperiosteal osteoid osteoma were reviewed. The patients ranged in age from 13 to 36 years with a mean of 24 years. Eight were male and three were female. Results and conclusion. Eleven subperiosteal lesions were studied. The reactive periostitis of four lesions was atypical and misleading. Four lesions had features similar to the more common intracortical variety. Three lesions occurring within the joint like other intra-articular lesions were barely seen on plain radiographs. Bone scan and CT scan were virtually diagnostic. The histopathology of these lesions was also atypical though not misleading. In conclusion, subperiosteal osteoid osteoma is a rare lesion with atypical radiographic and histopathologic features. The unusual reactive periostitis seen in several extra-articular cases may suggest other diagnoses. (orig.). With 4 figs., 2 tabs.

  7. Radiographic Evaluation of the Ankle Mortise

    Directory of Open Access Journals (Sweden)

    Hamid Mirbagheri

    2010-05-01

    Full Text Available The ankle joint is the most frequently injured joint in adults. Decisions on management are usually based on clinical examination and interpretation of the x-rays. Stability of the ankle mortise relies on the configuration of the osseous structures and the ligaments. A basic radiographic examination consists of a mortise-view and a lateral view. Some add the AP-view. The Mortise view is an AP-view with 15-25 degrees endorotation of the foot. "nThe view clearly demonstrates both lateral and medial joint spaces. On a true AP-view the talus overlaps a portion of the lateral malleolus obscuring the lateral aspect of the ankle joint. However, the AP-view will give you an extra view on both malleoli from a different angle. The lateral radiograph of the ankle should include the base of the fifth metatarsal because of the frequency of fractures at this side that clinically mimic a fracture of the ankle.

  8. Necrotizing fasciitis : plain radiographic and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Dae; Park, Jeong Hee; Jeon, Hae Jeong; Lim, Jong Nam; Heo, Tae Haeng; Park, Dong Rib [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate the plain radiographic and CT findings of the necrotizing fasciitis. We retrospectively reviewed the radiologic findings of 4 cases with necrotizing fasciitis. Three cases were proven pathologically. We evaluated pattern and extent of the gas shadows in plain films. CT findings were analysed, with emphasis on : (a) gas pattern, (b) extent, (c) location and involved site, (d) associated focal abscess, and (e) swelling of the adjacent muscles. On plain radiographs, four cases showed streaky or mottled gas densities in the pelvis, three cases in the perineum, one case in the abdomen, and two cases in the thigh. On CT images, gas pattern was mottled and streaky appearance with swelling of the adjacent muscles. Gas shadows located in the extraperitoneal space in four cases, fascial layer in four cases, and subcutaneous layer in four cases. There were gas shadows in pelvic wall, perineum, abdominal wall, buttock, thigh, and scrotum. Focal low density lesion suggestive of focal abscess was not visualized. Plain radiography is useful for early diagnosis of the necrotizing fasciitis and CT is very useful for detection of precise location and extent of the disease. CT is also useful for differentiation of necrotizing fasciitis from focal abscess and cellulitis.

  9. A radiographic study of the condylar hyperlasia

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Soo; Kim, Young Jin; Choi, Eui Hwan; Kim, Jae Duk [Chosun University, Kwangju (Korea, Republic of)

    1995-08-15

    Condylar hyperplasia is a self-limiting condition characterized by a slowly progressing, enlargement of the mandible that results in facial asymmetry and a cross bite maloccusion. The facial asymmetry, open bite or cross bite, and radio graphic evidence of an enlarged condyle confirm the diagnosis of condylar hyperplasia. The etiology of the condition is unknown. This condition usually first becomes apparent during the second decade of life, when one condyle continues to grow while the other is no longer active. Radiographically, the condyle may appear enlarged or the neck of the condyle may be elongated or both may occur, sometimes, however, no raiographically demonstrable condylar abnormality will be noted. Surgical correction with subcondylar osteotomy is the treatment choice. We have observed two cases of condylar hyperplsia occurred in the left mandibular condyle of 24-year-old and 35-year- old women. We obtained that two cases were shown the followed results; 1. Clinically, both cases was unilaterally developed on C/C area, with temporomandibular disorders and pain, facial asymmetry and malcclusion. 2. Radiographically, hyperplastic mass confined to the condyle. 3. Histopathologically, these cases shown increased hypertrophic region in parts, and lamellated bone wit h irregular trabeculae.

  10. New efficient catalyst for ammonia synthesis: barium-promoted cobalt on carbon

    DEFF Research Database (Denmark)

    Hagen, Stefan; Barfod, Rasmus; Fehrmann, Rasmus

    2002-01-01

    Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia......Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia...

  11. Obtaining of Nanostructured Powders of Barium and Strontium Hexaferrite by the Polymer Precursor Method

    Directory of Open Access Journals (Sweden)

    V.G. Kostishyn

    2015-12-01

    Full Text Available Studied the possibility of obtaining by precursors in the polymer nanostructured powders of barium hexaferrite BaFe12O19 and strontium hexaferrite SrFe12O19. The reagents were used as starting barium nitrate, strontium nitrate and ferric nitrate nonahydrate (III, and polyethylene glycol-400 used this technology as a polymer.

  12. Control on Crystal Forms of Ultrafine Barium Carbonate Particles and Study on its Mechanism

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Barium carbonate particles were prepared by using homogeneous precipitation method and co-precipitation method respectively. Through adding different crystalline controlling modifiers, Barium carbonate particles in five different shapes including linear, needle-like, pillarlike, sphere-like and dumbbell-like were synthesized. These particles were characterized by SEM and XRD, and their synthetic mechanism was discussed in this paper.

  13. Investigation on the effects of milling atmosphere on synthesis of barium ferrite/magnetite nanocomposite

    NARCIS (Netherlands)

    Molaei, M.J.; Ataie, A.; Raygan, S.; Picken,n S.J.

    2011-01-01

    In this research, barium ferrite /magnetite nanocomposites synthesized via a mechano-chemical route. Graphite was used in order to reduce hematite content of barium ferrite to magnetite to produce a magnetic nanocomposite. The effects of processing conditions on the powder characteristics were inves

  14. A barium-rich binary central star in Abell 70

    CERN Document Server

    Boffin, Henri M J; Frew, D J; Acker, A; Köppen, J; Moffat, A F J; Parker, Q A

    2011-01-01

    We have found the central star of Abell 70 (PN G038.1-25.4, hereafter A 70) to be a binary consisting of a G8 IV-V secondary and a hot white dwarf. The secondary shows enhanced Ba II and Sr II features, firmly classifying it as a barium star. The nebula is found to have Type-I chemical abundances with helium and nitrogen enrichment, which combined with future abundance studies of the central star, will establish A 70 as a unique laboratory for studying s-process AGB nucleosynthesis.

  15. Spectroscopic properties of trivalent praseodymium in barium yttrium fluoride

    Energy Technology Data Exchange (ETDEWEB)

    Di Bartolo, B. E-mail: dibartob@bc.edurinodiba@attbi.com; Bowlby, B.E

    2003-05-01

    We have conducted a spectroscopic investigation of Pr{sup 3+} in barium yttrium fluoride (BaY{sub 2}O{sub 8}). Two doping concentrations were used: BaY{sub 2}F{sub 8}:Pr{sup 3+} (0.3%) and BaY{sub 2}F{sub 8}:Pr{sup 3+} (1%). The measurements included absorption, luminescence under continuous and pulsed excitations, and thermal effects on some sharp lines. The experimental results were used to characterize this system.

  16. The Kerr nonlinearity of the beta-barium borate crystal

    DEFF Research Database (Denmark)

    Bache, Morten; Guo, Hairun; Zhou, Binbin;

    2013-01-01

    A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond...... experiments BBO is popular because of low dispersion and a high damage threshold. The main attractive property of ultrafast cascading is that the induced cascading nonlinearity nI 2, casc can be negative, i.e. generate a self-defocusing Kerr-like nonlinearity. However, the material Kerr nonlinearity nI 2...

  17. Susuk - black magic exposed "white" by dental radiographs.

    Science.gov (United States)

    F, Arishiya Thapasum; Mohammed, Faraz

    2014-07-01

    Susuk or charm needles are a facial cum body art widely practiced among women of Malaysia, Brunei, Singapore, Thailand and Indonesia. These are small, needle-shaped metallic talismans inserted subcutaneously in different parts of the body. The concealed art of susuk was "exposed" by routine radiographic examination in the oral and maxillofacial region. This paper reports two such cases of unusual incidental radiographic finding in dental radiographs which were taken on a routine basis as part of the diagnostic work up. This article will also primarily enlighten the importance of radiographs in detecting such charm needles as the wearer keeps the body art a "hidden secret" thereby avoiding misdiagnosis.

  18. Computer Analysis Of ILO Standard Chest Radiographs Of Pneumoconiosis

    Science.gov (United States)

    Li, C. C.; Shu, David B. C.; Tai, H. T.; Hou, W.; Kunkle, G. A.; Wang, Y.; Hoy, R. J.

    1982-11-01

    This paper presents study of computer analysis of the 1980 ILO standard chest radiographs of pneumoconiosis. Algorithms developed for detection of individual small rounded and irregular opacities have been experimented and evaluated on these standard radiographs. The density, shape, and size distribution of the detected objects in the lung field, in spite of false positives, can be used as indicators for the beginning of pneumoconiosis. This approach is potentially useful in computer-assisted screening and early detection process where the annual chest radiograph of each worker is compared with his (her) own normal radiograph obtained previously.

  19. LIGHTENING OF DARK RADIOGRAPHS BY A SUPER PROPORTIONAL REDUCING AGENT

    Directory of Open Access Journals (Sweden)

    A ZAMANI NASER

    2000-09-01

    Full Text Available Introduction. Occasionally over exposure or over development makes processed radiographs too dark, By reducing (Bleaching such a radiograph whit a reducing solution the dentist can enhance the image with low diagnostic value. Methods. Mandible of a dry skull with posterior teeth, double films pocket, intera oral radiography unit, diluted solution of fixer and developer, Coppor sulfate reducer solution, automatic processing unit. A radiograph was prepared with normal exposure time from posterior region of mandibule and saved as positive control. A series of double film pocket were exposed to obtian overexposed radiographs. One film from each pocket was used as the negative control and the other was reduced by copper sulfate solution. The diagnostic quality of reduced radiographs were evaluatel in three steps: 1. By clinical evaluation of reduced radiographs. 2. By densitometry of reduced radiographs. 3. By evaluation the number of steps wedges. Results. The diagnostic quality and resolution of reduced Radiographs were increased and their contrast was decreased. Discussion. Copper sulfate reducing agent is very good solution for improving diagnostic quality of very dark radiograph and prevent reexposure of the patient.

  20. Modified axillary radiograph of the shoulder: a new position.

    Science.gov (United States)

    Senna, Luís Filipe; Pires E Albuquerque, Rodrigo

    2017-01-01

    Obtaining axillary radiographs of the shoulder in acute trauma is not always feasible. The authors present a new modification of this radiographic view, in order to assess the anatomic relationship between the humeral head and the glenoid cavity. The incidence is performed with the patient sitting on X-ray table, with the affected limb supported thereon. The authors describe the case of a 28-year-old male who suffered an anterior glenohumeral dislocation that was clearly evidenced by this modified radiograph. The concentric relationship between the humeral head and the glenoid cavity was also easily confirmed by obtaining such radiograph after the reduction maneuver.

  1. Preparation of nanosized barium zirconate powder by thermal decomposition of urea in an aqueous solution containing barium and zirconium, and by calcination of the precipitate

    OpenAIRE

    Boschini, Frédéric; Robertz, B.; Rulmont, André; Cloots, Rudi

    2003-01-01

    The synthesis of barium zirconate was initiated by urea induced homogeneous precipitation followed by a "low temperature" thermal treatment. The kinetic of the reaction and the optimum urea/cation ratio have been determined by means of X-ray diffraction and Inductive Coupled Plasma analyses. It has been demonstrated that an amorphous zirconium hydrated oxide starts to precipitate followed by the precipitation of barium carbonate. A calcination at 1200 degreesC during 2 h gives rise to the for...

  2. Temperature dependence dielectric properties of modified barium titanate-PVB composites

    Science.gov (United States)

    Joshi, N. J.; Rakshit, P. B.; Grewal, G. S.; Shrinet, V.; Pratap, A.

    2013-06-01

    In this work, attempts are made to prepare ceramic polymer-composite followed by characterization of dielectric properties. The Barium Titanate ceramic powders are synthesized using the hydrothermal process. Silane treatment is carried out on Barium Titanate powder to increase its compatibility with polymer, followed with preparation of ceramic-polymer composite. Polyvinyl Butyral (PVB) is used as matrix for preparation of the composites and the concentration of Barium Titanate is increased from 60 to 90 wt%. Dielectric properties such as volume resistivity, dielectric constant, dissipation factor are evaluated. Results indicate that the dielectric constant and dissipation factor vary between 52 to 120 and 0.01 to 0.07; respectively as the relative ratio of polymer and silane modified Barium Titanate is varied. Specifically, at 90 wt% of silane modified Barium Titanate, the highest dielectric constant of 123 along with dissipation factor of 0.07 is obtained.

  3. Barium Tagging in Liquid Xenon for the nEXO Experiment

    Science.gov (United States)

    Kravitz, Scott; nEXO Collaboration

    2016-09-01

    nEXO is a next-generation experiment designed to search for neutrinoless double beta decay of xenon-136 in a liquid xenon time projection chamber. Positive observation of this decay would determine the neutrino to be a MAJORANA particle, as well as measure the absolute neutrino mass scale. In order to greatly reduce background contributions to this search, the collaboration is developing several ``barium tagging'' techniques to recover and identify the decay daughter, barium-136. Barium tagging may be available for a second phase of nEXO operation, allowing for neutrino mass sensitivity beyond the inverted mass hierarchy. Tagging methods for this phase include barium-ion capture on a probe with identification by resonance ionization laser spectroscopy. Inclusion of an argon ion gun in this system allows for improved cleaning and preparation of the barium deposition substrate, with recent results reported in this presentation.

  4. Anion and cation diffusion in barium titanate and strontium titanate; Anionen- und Kationendiffusion in Barium- und Strontiumtitanat

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, Markus Franz

    2012-12-19

    Perovskite oxides show various interesting properties providing several technical applications. In many cases the defect chemistry is the key to understand and influence the material's properties. In this work the defect chemistry of barium titanate and strontium titanate is analysed by anion and cation diffusion experiments and subsequent time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reoxidation equation for barium titanate used in multi-layer ceramic capacitors (MLCCs) is found out by a combination of different isotope exchange experiments and the analysis of the resulting tracer diffusion profiles. It is shown that the incorporation of oxygen from water vapour is faster by orders of magnitude than from molecular oxygen. Chemical analysis shows the samples contain various dopants leading to a complex defect chemistry. Dysprosium is the most important dopant, acting partially as a donor and partially as an acceptor in this effectively acceptor-doped material. TEM and EELS analysis show the inhomogeneous distribution of Dy in a core-shell microstructure. The oxygen partial pressure and temperature dependence of the oxygen tracer diffusion coefficients is analysed and explained by the complex defect chemistry of Dy-doped barium titanate. Additional fast diffusion profiles are attributed to fast diffusion along grain boundaries. In addition to the barium titanate ceramics from an important technical application, oxygen diffusion in cubic, nominally undoped BaTiO{sub 3} single crystals has been studied by means of {sup 18}O{sub 2}/{sup 16}O{sub 2} isotope exchange annealing and subsequent determination of the isotope profiles in the solid by ToF-SIMS. It is shown that a correct description of the diffusion profiles requires the analysis of the diffusion through the surface space-charge into the material's bulk. Surface exchange coefficients, space-charge potentials and bulk diffusion coefficients are analysed as a function of oxygen partial

  5. Tungsten and Barium Transport in the Internal Plasma of Hollow Cathodes

    Science.gov (United States)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2008-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the flow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushedback to the emitter surface by the electric field and drag from the xenon ion flow. Thisbarium ion flux is sufficient to maintain a barium surface coverage at the downstream endgreater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length,so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollowcathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  6. Proximal femoral canal shape is more accurately assessed on AP hip radiographs than AP pelvis radiographs in primary hip osteoarthritis.

    Science.gov (United States)

    Merle, Christian; Waldstein, Wenzel; Gregory, Jennifer S; Goodyear, Simon R; Aspden, Richard M; Aldinger, Peter R; Murray, David W; Gill, Harinderjit S

    2013-01-01

    The objectives of the present study were to determine whether differences in the radiographic appearance of the of the proximal femoral canal exist on corresponding AP pelvis and AP hip radiographs, and whether radiographic assessment of canal shape is accurate with reference to computed tomography (CT). In a retrospective study, corresponding radiographs and CT scans of 100 consecutive patients with primary hip OA were evaluated. Active shape modelling (ASM) was performed to assess the variation in proximal femoral canal shape and to identify differences between AP hip and AP pelvis views. Differences in the medial cortical flare between radiographs and CT were quantified using least squares curve fitting. ASM identified significant differences in the assessment of canal shape on corresponding AP hip and AP pelvis views. Curve fitting demonstrated a good agreement between AP hip radiographs and CT. Agreement between AP pelvis radiographs and CT was less good. In contrast to AP pelvis radiographs, AP hip radiographs allow a more accurate and reliable assessment of proximal femoral canal shape in the frontal plane in primary hip OA. Our findings may improve stem fit in total hip arthroplasty without the routine use of CT.

  7. Thermal expansion behaviour of barium and strontium zirconium phosphates

    Indian Academy of Sciences (India)

    P Srikari Tantri; K Geetha; A M Umarji; Sheela K Ramasesha

    2000-12-01

    Ba1.5–SrZr4P5SiO24 compounds with = 0, 0.25, 0.5, 0.75, 1.0, 1.25 and 1.5, belonging to the low thermal expansion NZP family were synthesized by the solid state reaction method. The XRD pattern could be completely indexed with respect to R$\\bar{3}$ space group indicating the ordering of vacancy at the divalent cation octahedral sites. The microstructure and bulk thermal expansion coefficient from room temperature to 800°C of the sintered samples have been studied. All the samples show very low coefficient of thermal expansion (CTE), with = 0 samples showing negative expansion. A small substitution of strontium in the pure barium compound changes the sign of CTE. Similarly, = 1.5 sample (pure strontium) shows a positive CTE and a small substitution of barium changes its sign. = 1.0 and 1.25 samples have almost constant CTE over the entire temperature range. The low thermal expansion of these samples can be attributed to the ordering of the ions in the crystal structure of these materials.

  8. Study of barium bismuth titanate prepared by mechanochemical synthesis

    Directory of Open Access Journals (Sweden)

    Lazarević Z.Ž.

    2009-01-01

    Full Text Available Barium-bismuth titanate, BaBi4Ti4O15 (BBT, a member of Aurivillius bismuth-based layer-structure perovskites, was prepared from stoichiometric amounts of barium titanate and bismuth titanate obtained via mechanochemical synthesis. Mechanochemical synthesis was performed in air atmosphere in a planetary ball mill. The reaction mechanism of BaBi4Ti4O15 and the preparation and characteristics of BBT ceramic powders were studied using XRD, Raman spectroscopy, particle analysis and SEM. The Bi-layered perovskite structure of BaBi4Ti4O15 ceramic forms at 1100 °C for 4 h without a pre-calcination step. The microstructure of BaBi4Ti4O15 exhibits plate-like grains typical for the Bi-layered structured material and spherical and polygonal grains. The Ba2+ addition leads to changes in the microstructure development, particularly in the change of the average grain size.

  9. Liquid-Phase Processing of Barium Titanate Thin Films

    Science.gov (United States)

    Harris, David Thomas

    Processing of thin films introduces strict limits on the thermal budget due to substrate stability and thermal expansion mismatch stresses. Barium titanate serves as a model system for the difficulty in producing high quality thin films because of sensitivity to stress, scale, and crystal quality. Thermal budget restriction leads to reduced crystal quality, density, and grain growth, depressing ferroelectric and nonlinear dielectric properties. Processing of barium titanate is typically performed at temperatures hundreds of degrees above compatibility with metalized substrates. In particular integration with silicon and other low thermal expansion substrates is desirable for reductions in costs and wider availability of technologies. In bulk metal and ceramic systems, sintering behavior has been encouraged by the addition of a liquid forming second phase, improving kinetics and promoting densification and grain growth at lower temperatures. This approach is also widespread in the multilayer ceramic capacitor industry. However only limited exploration of flux processing with refractory thin films has been performed despite offering improved dielectric properties for barium titanate films at lower temperatures. This dissertation explores physical vapor deposition of barium titanate thin films with addition of liquid forming fluxes. Flux systems studied include BaO-B2O3, Bi2O3-BaB2O 4, BaO-V2O5, CuO-BaO-B2O3, and BaO-B2O3 modified by Al, Si, V, and Li. Additions of BaO-B2O3 leads to densification and an increase in average grain size from 50 nm to over 300 nm after annealing at 900 °C. The ability to tune permittivity of the material improved from 20% to 70%. Development of high quality films enables engineering of ferroelectric phase stability using residual thermal expansion mismatch in polycrystalline films. The observed shifts to TC match thermodynamic calculations, expected strain from the thermal expansion coefficients, as well as x-ray diffract measurements

  10. Radiographer perceptions of managerial transformational leadership levels.

    Science.gov (United States)

    Legg, Jeffrey S; Akroyd, Duane; Jackowski, Melissa B

    2010-01-01

    Transformational leadership focuses on the ability of a leader to impact employees by inspiring employees to broaden interests in work as well as to be innovative and creative. It is positively associated with employee satisfaction and commitment to the organization. Characteristics of transformational leaders include confidence, ability to mange and deal with complexity, and belief in their employees and organizations. Considering the importance of leadership skills in radiology departments, this paper addresses directly the empirical evidence concerning radiographer's perception of their radiology managers and supervisors transformational leadership levels in the United States. Leadership can be taught, and we as a profession must begin to implement leadership training programs for our current and future leaders.

  11. Radiographic studies of the ventricles in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    West, R.J.; Williams, B.

    1980-08-01

    Radiographic investigations of 171 patients with communicating syringomyelia have been reviewed. Hydrocephalus was found in one third of the cases and has occasionally progressed after operation on the posterior fossa, sometimes with accompanying clinical deterioration. The outlets of the fourth ventricle were usually abnormal; tonsillar descent, arachnoiditis and both together were seen. Arachnoiditis correlated strongly with a history of difficult birth. The foramen of Magendie was sometimes patent and sometimes blocked. There was no consistent level of occlusion corresponding to a persistent roof of the fourth ventricle. The cisterna magna was usually small or obliterated but some examples of large cisterns or subarachnoid pouches were found. Radiological demonstration of a communication from the fourth ventricle to the syrinx occurred in only seven patients by positive contrast material and not by air. It is suggested that a sizable communication is rare at the time when patients seek treatment.

  12. Spinal cord injury without radiographic abnormality

    Directory of Open Access Journals (Sweden)

    Singh Anil

    2006-01-01

    Full Text Available Spinal cord injury without radiological abnormality is rare in adults. Below we present a case report of 20 yrs old male with isolated cervical cord injury, without accompanying vertebral dislocation or fracture involving the spinal canal rim. He fell down on plain and smooth ground while carrying 40 kg weight overhead and developed quadriparesis with difficulty in respiration. Plain radiographs of the neck revealed no fractures or dislocations. MRI showed bulky spinal cord and an abnormal hyper intense signal on the T2W image from C2 vertebral body level to C3/4 intervertebral disc level predominantly in the anterior aspect of the cord The patient was managed conservatively with head halter traction and invasive ventilatory support for the initial 7 days period in the ICU. In our patient recovery was good and most of the neurological deficit improved over 4 weeks with conservative management.

  13. Iterative Reconstruction of Coded Source Neutron Radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Bingham, Philip R [ORNL; Gregor, Jens [University of Tennessee, Knoxville (UTK)

    2013-01-01

    Use of a coded source facilitates high-resolution neutron imaging through magnifications but requires that the radiographic data be deconvolved. A comparison of direct deconvolution with two different iterative algorithms has been performed. One iterative algorithm is based on a maximum likelihood estimation (MLE)-like framework and the second is based on a geometric model of the neutron beam within a least squares formulation of the inverse imaging problem. Simulated data for both uniform and Gaussian shaped source distributions was used for testing to understand the impact of non-uniformities present in neutron beam distributions on the reconstructed images. Results indicate that the model based reconstruction method will match resolution and improve on contrast over convolution methods in the presence of non-uniform sources. Additionally, the model based iterative algorithm provides direct calculation of quantitative transmission values while the convolution based methods must be normalized base on known values.

  14. Experiences of being a therapy radiographer

    Directory of Open Access Journals (Sweden)

    Chris Myburgh

    2011-02-01

    Full Text Available The purpose of this research was to explore and describe how therapy radiographers experience their profession. A qualitative, exploratory, descriptive and contextual design was utilised. The purposive sample consisted of 14 therapy radiographers employed at an academic hospital in Gauteng, South Africa. Data were collected using focus group interviews until data saturation was achieved. An appreciative inquiry interview technique was utilised, and data analysis was conducted by open coding to identify themes. Themes that were identified were life-giving forces that promote personal and professional engagement resulting in a sense of purpose; professional stagnation; and facilitating change through harnessing positive energy and commitment for change.

    Opsomming

    Die hoofdoel van hierdie navorsing is om te verken en beskryf hoe radioterapeute hulle beroep beleef. ‘n Kwalitatiewe, verkennende, beskrywende en kontekstuele navorsingsontwerp is gebruik. Die doelgerigte steekproef het bestaan uit 14 radioterapeute werksaam by ‘n akademiese hospitaal in Gauteng, Suid Afrika. Data is met behulp van fokusgroep onderhoude ingesamel totdat dataversadiging bereik is. ‘n ‘Appreciative inquiry’ onderhoudstegniek is gebruik met die stel van vrae, en data analise is met behulp van oop kodering gedoen om temas te identifiseer. Die temas wat geidentifiseer was is lewensgewende magte wat persoonlike en professionele betrokkenheid bevorder wat ‘n singewing tot gevolg het; professionele stagnering; en fasilitering van verandering deur die gebruikmaking van positiewe energie en toewyding vir verandering.

    How to cite this article: Lawrence, H., Poggenpoel, M. & Myburgh, C., 2011,‘Experiences of being a therapy radiographer’, Health SA Gesondheid 16(1, Art.#596. 7 pages. http://dx.doi. org/10.4102/hsag.v16i1.596

  15. Radiopaque intrahepatic duct stones in plain radiograph: case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Young; Suh, Chang Hae; Park, Chan Sup; Chung, Won Kyun [College of Medicine, Inha University, Seongnam (Korea, Republic of)

    1994-04-15

    We experienced 3 cases of intrahepatic duct stones detected on plain radiographs. The patients had history of multiple episodes of recurrent cholangitis. Radiographic characteristics of these stones included multiple, round or rectangular radiopaque densities surrounded by calcified rim; these densities showed a branching pattern along the intrahepatic ducts.

  16. Comparative analysis of human and bovine teeth: radiographic density

    Directory of Open Access Journals (Sweden)

    Jefferson Luis Oshiro Tanaka

    2008-12-01

    Full Text Available Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s and the target-sensor distance (40 cm were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the "histogram" tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p 0.05. Based on the results, the authors concluded that: a the radiographic density of bovine enamel is significantly higher than that of human enamel; b the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c bovine teeth should be used with care in radiographic in vitro studies.

  17. Radiologist perceptions of radiographer role development in Scotland

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J. [School of Health Sciences, Robert Gordon University, Faculty of Health and Social Care, Garthdee Road, Garthdee, Aberdeen AB10 7QG (United Kingdom)]. E-mail: l.forsyth@rgu.ac.uk; Robertson, Elizabeth M. [Department of Radiology, Aberdeen Royal Infirmary, Foresterhill, Aberdeen AB25 2ZN (United Kingdom)]. E-mail: e.m.robertson@arh.grampian.scot.nhs.uk

    2007-02-15

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training.

  18. Radiographic features of mandibular trabecular bone structure in hypodontia

    NARCIS (Netherlands)

    M. Créton; W. Geraets; J.W. Verhoeven; P.F. van der Stelt; H. Verhey; M. Cune

    2012-01-01

    Purpose: Radiographic parameters of mandibular trabecular bone structure between 67 subjects having hypodontia and those without were studied on digital panoramic radiographs. Materials and Methods: Three regions of interest (ROI) were defined: the ascending ramus, apical of the mandibular molar and

  19. Radiographic Features of Mandibular Trabecular Bone Structure in Hypodontia

    NARCIS (Netherlands)

    Creton, Marijn; Geraets, Wil; Verhoeven, Jan Willem; van der Stelt, Paul F.; Verhey, Hans; Cune, Marco

    2012-01-01

    Purpose: Radiographic parameters of mandibular trabecular bone structure between 67 subjects having hypodontia and those without were studied on digital panoramic radiographs. Materials and Methods: Three regions of interest (ROI) were defined: the ascending ramus, apical of the mandibular molar and

  20. Inferring Morphology and Strength of Magnetic Fields From Proton Radiographs

    CERN Document Server

    Graziani, Carlo; Lamb, Donald Q; Li, Chikang

    2016-01-01

    Proton radiography is an important diagnostic method for laser plasma experiments, and is particularly important in the analysis of magnetized plasmas. The theory of radiographic image analysis has heretofore only permitted somewhat limited analysis of the radiographs of such plasmas. We furnish here a theory that remedies this deficiency. We show that to linear order in magnetic field gradients, proton radiographs are projection images of the MHD current along the proton trajectories. We demonstrate that in the linear approximation, the full structure of the perpedicular magnetic field can be reconstructed by solving a steady-state inhomogeneous 2-dimensional diffusion equation sourced by the radiograph fluence contrast data. We explore limitations of the inversion method due to Poisson noise, to discretization errors, to radiograph edge effects, and to obstruction by laser target structures. We also provide a separate analysis that is well-suited to the inference of isotropic-homogeneous magnetic turbulence...

  1. Preparation of Barium Titanate Nanopowder through Thermal Decomposition of Peroxide Precursor and Its Formation Mechanism

    Institute of Scientific and Technical Information of China (English)

    PENG, Yangxi; CHEN, Qiyuan; LIU, Shijun

    2009-01-01

    H_2TiO_3 was dissolved in the mixture of hydrogen formed peroxide and ammonia under the pH range of 8-10 with a transparent yellow solution formed. When an equivalent mole of Ba~(2+) solution was added into the yellow solution, the precipitate produced was the peroxide precursor of barium titanate. The cubic nanopowder of barium titanate was obtained when the precipitate was washed, stoved, and then calcined at 600 ℃ for 1 h. The peroxide precursor of barium titanate and barium titanate nanopowder prepared were characterized to be BaTi(H_2O_2)_2O_3 by TGA-DTA, XRD, TEM, SEM, and XREDS. The peroxide precursor of barium titanate was determined to be BaTi(H_2O_2)_2O_3. The particle size of the barium titanate nanopowder, the calcined product of BaTi(H_2O_2)_2O_3, was in the range of 20-40 nm. A formation mechanism of the barium titanate nanopowder through thermal decomposition of its peroxide precursor was proposed and then validated.

  2. Bio-based barium alginate film: Preparation, flame retardancy and thermal degradation behavior.

    Science.gov (United States)

    Liu, Yun; Zhang, Chuan-Jie; Zhao, Jin-Chao; Guo, Yi; Zhu, Ping; Wang, De-Yi

    2016-03-30

    A bio-based barium alginate film was prepared via a facile ionic exchange and casting approach. Its flammability, thermal degradation and pyrolysis behaviors, thermal degradation mechanism were studied systemically by limiting oxygen index (LOI), vertical burning (UL-94), microscale combustion calorimetry (MCC), thermogravimetric analysis (TGA) coupled with Fourier transform infrared analysis (FTIR) and pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). It showed that barium alginate film had much higher LOI value (52.0%) than that of sodium alginate film (24.5%). Moreover, barium alginate film passed the UL-94 V-0 rating, while the sodium alginate film showed no classification. Importantly, peak of heat release rate (PHRR) of barium alginate film in MCC test was much lower than that of sodium alginate film, suggested that introduction of barium ion into alginate film significantly decreased release of combustible gases. TG-FTIR and Py-GC-MS results indicated that barium alginate produced much less flammable products than that of sodium alginate in whole thermal degradation procedure. Finally, a possible degradation mechanism of barium alginate had been proposed.

  3. Magnetic properties of Ni substituted Y-type barium ferrite

    Energy Technology Data Exchange (ETDEWEB)

    Won, Mi Hee; Kim, Chul Sung, E-mail: cskim@kookmin.ac.kr [Department of Physics, Kookmin University, Seoul 136-702 (Korea, Republic of)

    2014-05-07

    Y-type barium hexaferrite is attractive material for various applications, such as high frequency antennas and RF devices, because of its interesting magnetic properties. Especially, Ni substituted Y- type hexaferrites have higher magnetic ordering temperature than other Y-type. We have investigated macroscopic and microscopic properties of Y-type barium hexaferrite. Ba{sub 2}Co{sub 2−x}Ni{sub x}Fe{sub 12}O{sub 22} (x = 0, 0.5, 1.0, 1.5, and 2.0) samples are prepared by solid-state reaction method and studied by X-ray diffraction (XRD), vibrating sample magnetometer, and Mössbauer spectroscopy, as well as a network analyzer for high frequency characteristics. The XRD pattern is analyzed by Rietveld refinement method and confirms the hexagonal structure with R-3m. The hysteresis curve shows ferrimagnetic behavior. Saturation magnetization (M{sub s}) decreases with Ni contents. Ni{sup 2+}, which preferentially occupies the octahedral site with up-spin sub-lattice, has smaller spin value S of 1 than Co{sup 2+} having S = 3/2. The zero-field-cooled (ZFC) measurement of Ba{sub 2}Co{sub 1.5}Ni{sub 0.5}Fe{sub 12}O{sub 22} shows that Curie and spin transition temperatures are found to be 718 K and 209 K, respectively. The Curie temperature T{sub C} is increased with Ni contents, while T{sub S} is decreased with Ni. The Mössbauer spectra were measured at various temperatures and fitted by using a least-squares method with six sextet of six Lorentzian lines for Fe sites, corresponding to the 3b{sub VI}, 6c{sub IV}*, 6c{sub VI}, 18h{sub VI}, 6c{sub IV}, and 3a{sub IV} sites at below T{sub C}. From Mössbauer measurements, we confirmed the spin state of Fe ion to be Fe{sup 3+} and obtained the isomer shift (δ), magnetic hyperfine field (H{sub hf}), and the occupancy ratio of Fe ions at six sub-lattices. The complex permeability and permittivity are measured between 100 MHz and 4 GHz, suggesting that Y-type barium hexaferrite is promising for antenna

  4. Magnetic properties of Ni substituted Y-type barium ferrite

    Science.gov (United States)

    Won, Mi Hee; Kim, Chul Sung

    2014-05-01

    Y-type barium hexaferrite is attractive material for various applications, such as high frequency antennas and RF devices, because of its interesting magnetic properties. Especially, Ni substituted Y- type hexaferrites have higher magnetic ordering temperature than other Y-type. We have investigated macroscopic and microscopic properties of Y-type barium hexaferrite. Ba2Co2-xNixFe12O22 (x = 0, 0.5, 1.0, 1.5, and 2.0) samples are prepared by solid-state reaction method and studied by X-ray diffraction (XRD), vibrating sample magnetometer, and Mössbauer spectroscopy, as well as a network analyzer for high frequency characteristics. The XRD pattern is analyzed by Rietveld refinement method and confirms the hexagonal structure with R-3m. The hysteresis curve shows ferrimagnetic behavior. Saturation magnetization (Ms) decreases with Ni contents. Ni2+, which preferentially occupies the octahedral site with up-spin sub-lattice, has smaller spin value S of 1 than Co2+ having S = 3/2. The zero-field-cooled (ZFC) measurement of Ba2Co1.5Ni0.5Fe12O22 shows that Curie and spin transition temperatures are found to be 718 K and 209 K, respectively. The Curie temperature TC is increased with Ni contents, while TS is decreased with Ni. The Mössbauer spectra were measured at various temperatures and fitted by using a least-squares method with six sextet of six Lorentzian lines for Fe sites, corresponding to the 3bVI, 6cIV*, 6cVI, 18hVI, 6cIV, and 3aIV sites at below TC. From Mössbauer measurements, we confirmed the spin state of Fe ion to be Fe3+ and obtained the isomer shift (δ), magnetic hyperfine field (Hhf), and the occupancy ratio of Fe ions at six sub-lattices. The complex permeability and permittivity are measured between 100 MHz and 4 GHz, suggesting that Y-type barium hexaferrite is promising for antenna applications in UHF band.

  5. Barium ferrite nanoparticles prepared by self-propagating low-temperature combustion method and its characterization

    Indian Academy of Sciences (India)

    P M Prithviraj Swamy; S Basavaraja; Vijayanand Havanoor; N V Srinivas Rao; R Nijagunappa; A Venkataraman

    2011-12-01

    The barium ferrite particles were prepared using a self-propagating low-temperature combustion method using polyethylene glycol (PEG) as a fuel. The process was investigated with simultaneous thermogravimetric-differential thermal analysis (TG–DTA). The crystalline structure, morphology and the magnetic properties of the barium ferrite particles were studied by means of X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and SQUID susceptometer. The results show that the ignition temperature of PEG is lower compared with other combustion methods and gives nanocrystalline barium ferrite.

  6. Addition of methyl cellulose enema to double-contrast barium imaging of sigmoid diverticulosis

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, R. [Malmoe Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Adnerhill, I. [Malmoe Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Bjoerkdahl, P. [Malmoe Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Ekberg, O. [Malmoe Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Fork, F.T. [Malmoe Univ. Hospital (Sweden). Dept. of Diagnostic Radiology

    1997-01-01

    Double-contrast barium enema has a reduced sensitivity in patients with severe sigmoid diverticulosis. Therefore a carboxy methyl cellulose enema was employed after the conventional double-contrast examination in 15 patients with sigmoid diverticulosis. A significant increase in lumen diameter and a superior removal of barium residue from the diverticulas facilitated the interpretation of the sigmoid loops. Conclusion: The addition of methyl cellulose enema to double-contrast barium imaging improves diagnostic imaging in diverticulosis by expanding the lumen and emptying the diverticulas. (orig.).

  7. A Comparative Study on Magnetostructural Properties of Barium Hexaferrite Powders Prepared by Polyethylene Glycol

    Directory of Open Access Journals (Sweden)

    Zehra Durmus

    2014-01-01

    Full Text Available Nanocrystalline particles of barium hexaferrite were synthesized by a sol-gel combustion route using nitrate-citrate gels prepared from metal nitrates and citric acid solutions with Fe/Ba molar ratio 12. The present paper aims to study the effect of addition of polyethylene glycol (PEG solutions with different molecular weights (MW: 400, 2000, and 10.000 g/mol on magnetostructural properties of barium hexaferrite. The formation of the barium hexaferrite was inspected using X-ray diffraction (XRD analysis, Fourier transform infrared (FT-IR analysis, thermogravimetric (TGA analysis, scanning electron microscopy (SEM analysis and vibrating sample magnetometer (VSM analysis for magnetic measurements.

  8. A radiographic study of solitary bone cysts

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Rak; Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral and Maxillofacial Radiology, Division of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1994-02-15

    The aim of this study was to evaluate the clinical, radiographic and histopathologic features of 23 cases of solitary bone cyst by means of the analysis of radiographs and biopsy specimens in 23 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chunbuk National University. The obtained results were as follows; 1. The incidence of solitary bone cyst was almost equal in males (52.2%) and in females(42.8%) and the prevalent age of the solitary bone cyst were the second decade (47.8%) and the third decade (21.7%). 2. In the signs and symptoms of solitary bone cyst, pain or tenderness revealed in 17.4%, swelling revealed in 13.0%, pain and swelling revealed in 21.7%, paresthesia revealed in 4.4% and 43.5% were a symptom and the tooth vitality involved in the solitary bone cyst, 76.5% were posterior and 23.5% were either positive or negative. 3. In the location of the solitary bone cyst, 47.8% present posterior region, 21.7% present anterior region, 21.6% present anterior and posterior region, 4.4% present condylar process area. 4. In the hyperostotic border of the solitary bone cyst, 47.8% were seen entirely, 21.8% were seen partially, and 30.4% were not seen. 5. In the change of tooth, 59.1% were loss of the alveolar lamina dura, 13.6% were root resorption 4.55% were tooth displacement, 4.55% were root resorption and tooth displacement. 6. In the change of cortical bone of the solitary bone cyst, 39.1% were intact and 60.9% were thinning and expansion of cortical bone. 7. In the histopathologic findings of 9 cases, 33.3% were thin connective tissue wall, 11.1% were thickened myxo-fibromatous wall, 55.6% were thickened myxofibromatous wall with dysplastic bone formation.

  9. Physico-chemical study of barium (II) dipivaloylmethanate nature

    Energy Technology Data Exchange (ETDEWEB)

    Fedotova, N.E. [Rossijskaya Akademiya Nauk, Novosibirsk (Russian Federation). Inst. of Inorganic Chemistry; Igumenov, I.K. [Rossijskaya Akademiya Nauk, Novosibirsk (Russian Federation). Inst. of Inorganic Chemistry; Mamatyuk, V.I. [Rossijskaya Akademiya Nauk, Novosibirsk (Russian Federation). Inst. of Inorganic Chemistry; Sidorenko, G.V. [Rossijskaya Akademiya Nauk, Novosibirsk (Russian Federation). Inst. of Inorganic Chemistry

    1995-06-01

    A physico-chemical research of bis-(dipivaloylmethanato)barium(II) (Ba(thd){sub 2}) has been carried out from the point of its use in CVD processes as a precursor (thermal stability, immunity to external effects and etc.). The optimal conditions for synthesis, purification and storage have been found. It has been shown, that the sublimated product presents a mixture of several modifications with the main phase of a composition Ba{sub 4}(thd){sub 8}. At a lowered pressure the sublimated product is preserved without decomposition for a long time. In the air it is a monomer of a composition Ba(thd){sub 2}*2H{sub 2}O, decomposing in the course of time with forming a free ligand or a diketone (C{sub 8}H{sub 21}O{sub 2}) depending on the way of purification of the initial compound. (orig.).

  10. Synthesis and optical study of barium magnesium aluminate blue phosphors

    Science.gov (United States)

    Jeet, Suninder; Sharma, Manoj; Pandey, O. P.

    2015-05-01

    Europium doped barium magnesium aluminate (BaMgAl10O17:Eu2+) phosphor was prepared via solution combustion method at 550°C using urea as a fuel. Morphological and optical properties of the prepared sample was studied by X-ray diffraction (XRD), Transmission electron microscopy (TEM) and Photoluminescence spectroscopy (PL). XRD result showed the formation of pure phase BaMgAl10O17(JCPDS 26-0163) along with an additional phase BaAl2O4(JCPDS 01-082-1350). TEM image indicated the formation of faceted particles with average particle size 40 nm. From PL spectra, a broad emission band obtained at about 450 nm attributes to 4f6 5d → 4f7 transition of Eu2+ which lies in the blue region of the visible spectrum.

  11. Synthesis and optical study of barium magnesium aluminate blue phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Jeet, Suninder, E-mail: suninder.jeet@thapar.edu; Pandey, O. P., E-mail: oppandey@thapar.edu [School of Physics and Materials Science, Thapar University, Patiala (147003), Punjab (India); Sharma, Manoj, E-mail: manojnarad@sggswu.org [Department of Nanotechnology, Sri Guru Granth Sahib World University, Fatehgarh Sahib(146406), Punjab (India)

    2015-05-15

    Europium doped barium magnesium aluminate (BaMgAl{sub 10}O{sub 17}:Eu{sup 2+}) phosphor was prepared via solution combustion method at 550°C using urea as a fuel. Morphological and optical properties of the prepared sample was studied by X-ray diffraction (XRD), Transmission electron microscopy (TEM) and Photoluminescence spectroscopy (PL). XRD result showed the formation of pure phase BaMgAl{sub 10}O{sub 17}(JCPDS 26-0163) along with an additional phase BaAl{sub 2}O{sub 4}(JCPDS 01-082-1350). TEM image indicated the formation of faceted particles with average particle size 40 nm. From PL spectra, a broad emission band obtained at about 450 nm attributes to 4f{sup 6} 5d → 4f{sup 7} transition of Eu{sup 2+} which lies in the blue region of the visible spectrum.

  12. A new type of microphone using flexoelectric barium strontium titnate

    Science.gov (United States)

    Kwon, Seol ryung; Huang, Wenbin; Zhang, Shujun; Yuan, Fuh-Gwo; Jiang, Xiaoning

    2014-03-01

    A flexoelectric bridge-structured microphone using bulk barium strontium titanate (Ba0.65Sr0.35TiO3 or BST) ceramic was investigated in this study. The flexoelectric microphone was installed in an anechoic box and exposed to the sound pressure emitted from a loud speaker. Charge sensitivity of the flexoelectric microphone was measured and calibrated using a reference microphone. The 1.5 mm×768 μm×50 μm micro-machined bridge-structured flexoelectric microphone has a sensitivity of 0.92 pC/Pa, while its resonance frequency was calculated to be 98.67 kHz. The analytical and experimental results show that the flexoelectric microphone has both high sensitivity and broad bandwidth, indicating that flexoelectric microphones are potential candidates for many applications.

  13. Influence of Barium Hexaferrite on Magnetic Properties of Hydroxyapatite Ceramics.

    Science.gov (United States)

    Jarupoom, P; Jaita, P

    2015-11-01

    Hydroxyapatite (HA) powders was derived from natural bovine bone by sequence of thermal processes. The barium hexaferrite (BF) find magnetic powders were added into HA powders in ratio of 1-3 vol.%. The HA-BF ceramics were prepared by a solid state reaction method and sintered at 1250 degrees C for 2 h. Effects of BF additive on structural, physical and magnetic properties of HA ceramics were investigated. X-ray diffraction revealed that all HA-BF samples showed a main phase of high purity hydroxyapatite [Ca10(PO4)6(OH)2] with calcium and phosphate molar ratio of 1.67. The addition of BF into HA inhibited grain growth and caused an improvement of mechanical properties. The M-H hysteresis loops also showed an improvement in magnetic behavior for higher content of BF. Moreover, in vitro bioactivity test indicated that the 2-3 vol.% sample may be suitable for biological applications.

  14. Barium depletion study on impregnated cathodes and lifetime prediction

    Energy Technology Data Exchange (ETDEWEB)

    Roquais, J.M.; Poret, F.; Doze, R. le; Ricaud, J.L.; Monterrin, A.; Steinbrunn, A

    2003-06-15

    In the thermionic cathodes used in cathode ray-tubes (CRTs), barium is the key element for the electronic emission. In the case of the dispenser cathodes made of a porous tungsten pellet impregnated with Ba, Ca aluminates, the evaporation of Ba determines the cathode lifetime with respect to emission performance in the CRT. The Ba evaporation results in progressive depletion of the impregnating material inside the pellet. In the present work, the Ba depletion with time has been extensively characterized over a large range of cathode temperature. Calculations using the depletion data allowed modeling of the depletion as a function of key parameters. The link between measured depletion and emission in tubes has been established, from which an end-of-life criterion was deduced. Taking modeling into account, predicting accelerated life-tests were performed using high-density maximum emission current (MIK)

  15. Analysis of barium hydroxide and calcium hydroxide slurry carbonation reactors

    Energy Technology Data Exchange (ETDEWEB)

    Patch, K.D.; Hart, R.P.; Schumacher, W.A.

    1980-05-01

    The removal of CO/sub 2/ from air was investigated by using a continuous-agitated-slurry carbonation reactor containing either barium hydroxide (Ba(OH)/sub 2/) or calcium hydroxide (Ca(OH)/sub 2/). Such a process would be applied to scrub /sup 14/CO/sub 2/ from stack gases at nuclear-fuel reprocessing plants. Decontamination factors were characterized for reactor conditions which could alter hydrodynamic behavior. An attempt was made to characterize reactor performance with models assuming both plug flow and various degrees of backmixing in the gas phase. The Ba(OH)/sub 2/ slurry enabled increased conversion, but apparently the process was controlled under some conditions by phenomena differing from those observed for carbonation by Ca(OH)/sub 2/. Overall reaction mechanisms are postulated.

  16. A buffer gas cooled beam of barium monohydride

    Science.gov (United States)

    Iwata, Geoffrey; Tarallo, Marco; Zelevinsky, Tanya

    2016-05-01

    Significant advances in direct laser cooling of diatomic molecules have opened up a wide array of molecular species to precision studies spanning many-body physics, quantum collisions and ultracold dissociation. We present a cryogenic beam source of barium monohydride (BaH), and study laser ablation of solid precursor targets as well as helium buffer gas cooling dynamics. Additionally, we cover progress towards a molecular magneto-optical trap, with spectroscopic studies of relevant cooling transitions in the B2 Σ molecules, including resolution of hyperfine structure and precision measurements of the vibrational Frank-Condon factors. Finally, we examine the feasibility of photo dissociation of trapped BaH molecules to yield optically accessible samples of ultracold hydrogen.

  17. Infrared Spectroscopic Characterization of Calcium and Barium Hydrazone Complexes

    Directory of Open Access Journals (Sweden)

    *A. Adeniyi

    2013-06-01

    Full Text Available Hydrazones have attracted considerable interest on account of their biological activities. Introduction of calcium and barium metal ions into m- and p-nitrobenzoic hydrazones is expected to modify these biological properties for enhanced activity and versatility. The ligands were synthesized from the parent acids. The complexes have been characterized using C, H and N microanalyses and IR spectrometry. The IR spectral data of the ligands and complexes revealed bonding via the C=O and C=N groups. The suggested metal to ligand stoichiometries are: [M (m-NBHx]Cl2.yH2O, x, y = 1 and 4 for M = Ca; x, y = 2 and 3 for M = Ba respectively. [M(p-NBHx]Cl2.yH2O, x, y = 1 and 12 for M = Ca; x, y = 1 and 3 for M = Ba respectively. The structural deductions are tentative pending future X-ray structural studies.

  18. Communication: Barium ions and helium nanodroplets: solvation and desolvation.

    Science.gov (United States)

    Zhang, Xiaohang; Drabbels, Marcel

    2012-08-07

    The solvation of Ba(+) ions created by the photoionization of barium atoms located on the surface of helium nanodroplets has been investigated. The excitation spectra corresponding to the 6p (2)P(1/2) ← 6s (2)S(1/2) and 6p (2)P(3/2) ← 6s (2)S(1/2) transitions of Ba(+) are found to be identical to those recorded in bulk He II [H. J. Reyher, H. Bauer, C. Huber, R. Mayer, A. Schafer, and A. Winnacker, Phys. Lett. A 115, 238 (1986)], indicating that the ions formed at the surface of the helium droplets become fully solvated by the helium. Time-of-flight mass spectra suggest that following the excitation of the solvated Ba(+) ions, these are being ejected from the helium droplets either as bare Ba(+) ions or as small Ba(+)He(n) (n < 20) complexes.

  19. Ionoluminescence of trivalent rare-earth-doped strontium barium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Calvo del Castillo, H. [Departamento de Geologia y Geoquimica, Universidad Autonoma de Madrid, Modulo C-VI, Campus de Cantoblanco, 28049 Cantoblanco, Madrid (Spain); Universidad Nacional Automoma de Mexico, Instituto de Fisica, 04510 Ciudad Universitaria, Mexico D.F. (Mexico); Ruvalcaba, J.L. [Universidad Nacional Automoma de Mexico, Instituto de Fisica, 04510 Ciudad Universitaria, Mexico D.F. (Mexico); Bettinelli, M.; Speghini, A. [Dipartimento Scientifico e Tecnologico, Universita di Verona and INSTM, UdR Verona, Ca Vignal, Strada Le Grazie 15, I-37134 Verona (Italy); Barboza Flores, M. [Centro de Investigacion en Fisica, Universidad de Sonora, Hermosillo, Sonora (Mexico); Calderon, T. [Departamento de Geologia y Geoquimica, Universidad Autonoma de Madrid, Modulo C-VI, Campus de Cantoblanco, 28049 Cantoblanco, Madrid (Spain)], E-mail: tomas.calderon@uam.es; Jaque, D.; Garcia Sole, J. [Departamento de Fisica de Materiales, Universidad Autonoma de Madrid, 28049 Cantoblanco, Madrid (Spain)

    2008-05-15

    Ionoluminescence spectra for different rare-earth ion (Pr{sup 3+} and Eu{sup 3+})-activated Sr{sub x}Ba{sub 1-x}Nb{sub 2}O{sub 6} strontium barium niobate crystals (x=0.33 and 0.60) have been induced with a 3 MeV proton beam for a variety of beam current intensities (45, 40 and 20 nA). The proton-beam induced luminescent spectra have shown features associated with the presence of the rare-earth ion and some spectral features mostly related to the host crystal, which appear only for high beam current intensities. We have compared the ionoluminescence results to those obtained under UV light excitation (photoluminescence technique) where a direct excitation of the band gap would occur.

  20. Structural and functional characterization of barium zirconium titanate / epoxy composites

    Directory of Open Access Journals (Sweden)

    Filiberto González Garcia

    2011-12-01

    Full Text Available The dielectric behavior of composite materials (barium zirconium titanate / epoxy system was analyzed as a function of ceramic concentration. Structure and morphologic behavior of the composites was investigated by X-ray Diffraction (XRD, Fourier transformed infrared spectroscopy (FT-IR, Raman spectroscopy, field emission scanning electron microscopy (FE-SEM and transmission electron microscopy (TEM analyses. Composites were prepared by mixing the components and pouring them into suitable moulds. It was demonstrated that the amount of inorganic phase affects the morphology of the presented composites. XRD revealed the presence of a single phase while Raman scattering confirmed structural transitions as a function of ceramic concentration. Changes in the ceramic concentration affected Raman modes and the distribution of particles along into in epoxy matrix. Dielectric permittivity and dielectric losses were influenced by filler concentration.

  1. Effect of Nb on barium titanate prepared from citrate solutions

    Directory of Open Access Journals (Sweden)

    Stojanović Biljana D.

    2002-01-01

    Full Text Available The influence of the addition of dopants on the microstructure development and electrical properties of BaTiO3 doped with 0.2, 0.4, 0.6, 0.8 mol% of Nb and 0.01 mol% of Mn based compounds was studied. Doped barium titanate was prepared using the polymeric precursor method from citrate solutions. The powders calcined at 700°C for 4 hours were analysed by infrared (IR spectroscopy to verify the presence of carbonates, and by X-ray diffraction (XRD for phase formation. The phase composition, microstructure and dielectric properties show a strong dependence on the amount of added niobium.

  2. Calcium, Strontium and Barium Homogeneous Catalysts for Fine Chemicals Synthesis.

    Science.gov (United States)

    Sarazin, Yann; Carpentier, Jean-François

    2016-12-01

    The large alkaline earths (Ae), calcium, strontium and barium, have in the past 15 years yielded a brand new generation of heteroleptic molecular catalysts for the production of fine chemicals. However, the integrity of these complexes is often plagued by ligand redistribution equilibria in solution. This personal account retraces the paths followed in our research group towards the design of stable heteroleptic alkalino-earth complexes, including the use of intramolecular noncovalent Ae···H-Si and Ae···F-C interactions. Their implementation as homogenous precatalysts for reactions such as the intramolecular and intermolecular hydroamination and hydrophosphination of activated alkenes, the hydrophosphonylation of ketones, and the dehydrogenative coupling of amines and hydrosilanes that enable the efficient and controlled formations of CP, CN, or SiN σ-bonds, is presented in a synthetic perspective that highlights their overall outstanding catalytic performance.

  3. Preparation and Characterization of Nano-particle Substituted Barium Hexaferrite

    CERN Document Server

    Atassi, Yomen; Tally, Mohammad

    2014-01-01

    High density magnetic recording requires high coercivity magnetic media and small particle size. Barium hexaferrite has been considered as a leading candidate material because of its chemical stability, fairly large crystal anisotropy and suitable magnetic characteristics. In this work, we present the preparation of the hexagonal ferrite BaFe12O19 and one of its derivative; the Zn-Sn substituted hexaferrite by the chemical co-precipitation method. The main advantage of this method on the conventional glass-ceramic one, resides in providing a small enough particle size for magnetic recording. We demonstrate using the X-ray diffraction patterns that the particle size decreases when substituting the hexaferrite by the Zn-Sn combination. This may improve the magnetic properties of the hexaferrite as a medium for HD magnetic recording

  4. Barium and carbon fluxes in the Canadian Arctic Archipelago

    Science.gov (United States)

    Thomas, Helmuth; Shadwick, Elizabeth; Dehairs, Frank; Lansard, Bruno; Mucci, Alfonso; Navez, Jacques; Gratton, Yves; Prowe, Friederike; Chierici, Melissa; Fransson, Agneta; Papakyriakou, Tim N.; Sternberg, Erika; Miller, Lisa A.; Tremblay, Jean-ÉRic; Monnin, Christophe

    2011-09-01

    The seasonal and spatial variability of dissolved Barium (Ba) in the Amundsen Gulf, southeastern Beaufort Sea, was monitored over a full year from September 2007 to September 2008. Dissolved Ba displays a nutrient-type behavior: the maximum water column concentration is located below the surface layer. The highest Ba concentrations are typically observed at river mouths, the lowest concentrations are found in water masses of Atlantic origin. Barium concentrations decrease eastward through the Canadian Arctic Archipelago. Barite (BaSO4) saturation is reached at the maximum dissolved Ba concentrations in the subsurface layer, whereas the rest of the water column is undersaturated. A three end-member mixing model comprising freshwater from sea-ice melt and rivers, as well as upper halocline water, is used to establish their relative contributions to the Ba concentrations in the upper water column of the Amundsen Gulf. Based on water column and riverine Ba contributions, we assess the depletion of dissolved Ba by formation and sinking of biologically bound Ba (bio-Ba), from which we derive an estimate of the carbon export production. In the upper 50 m of the water column of the Amundsen Gulf, riverine Ba accounts for up to 15% of the available dissolved Ba inventory, of which up to 20% is depleted by bio-Ba formation and export. Since riverine inputs and Ba export occur concurrently, the seasonal variability of dissolved Ba in the upper water column is moderate. Assuming a fixed organic carbon to bio-Ba flux ratio, carbon export out of the surface layer is estimated at 1.8 ± 0.45 mol C m-2 yr-1. Finally, we propose a climatological carbon budget for the Amundsen Gulf based on recent literature data and our findings, the latter bridging the surface and subsurface water carbon cycles.

  5. Static rearfoot alignment: a comparison of clinical and radiographic measures.

    Science.gov (United States)

    Lamm, Bradley M; Mendicino, Robert W; Catanzariti, Alan R; Hillstrom, Howard J

    2005-01-01

    Foot structure is typically evaluated using static clinical and radiographic measures. To date, the literature is devoid of a correlation between rearfoot frontal plane radiographic parameters and clinical measures of alignment. In a repeated-measures study comparing radiographic and clinical rearfoot alignment in 24 healthy subjects, radiographic angular measurements were made from standard weightbearing anteroposterior, lateral, long leg calcaneal axial, and rearfoot alignment views. Clinical measurements were made using a jig and scanner to assess the malleolar valgus index and a goniometer to evaluate the resting and neutral calcaneal stance positions. There was a significant correlation between frontal plane radiographic angles (long leg calcaneal axial and rearfoot alignment views) (r = 0.814). Similarly, there was a significant correlation between clinical measures (resting calcaneal stance position and malleolar valgus index) (r = 0.714). A multivariate stepwise regression showed that resting calcaneal stance position can be accurately predicted from 3 of the 15 clinical and radiographic measurements collected: malleolar valgus index, rearfoot alignment view, and long leg calcaneal axial view (r = 0.829). In summary, a commonly used clinical measure of static rearfoot alignment, resting calcaneal stance position, was correlated closely with the malleolar valgus index and both frontal plane radiographic parameters.

  6. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Mahdian, Mina; Sheth, Sonam; Chandhoke, Taranpreet K.; Gopalakrishna, Aadarsh; Potluri, Anitha; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

  7. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  8. Burnout in therapy radiographers in the UK.

    Science.gov (United States)

    Probst, H; Griffiths, S; Adams, R; Hill, C

    2012-09-01

    The 2007 UK National Radiotherapy Advisory Group report indicated that the number and type of staff available is one of the "rate-limiting" steps in improving productivity in radiotherapy departments. Retaining well-trained, satisfied staff is key to meeting the objectives of the report; burnout is an important factor linked to satisfaction and attrition. The results of a survey measuring burnout in a sample of radiotherapists (therapy radiographers) are presented and considered against norms for the health sector and burnout in therapists from Canada and the USA. Case study methodology was used studying six radiotherapy departments selected because of close geographical proximity and differing vacancy rates for radiotherapists. An anonymous survey of radiotherapists used the Maslach Burnout Inventory (MBI) and other workforce-related measures (e.g. job satisfaction scales, measures of professional plateau, intentions to leave, job characteristics and demographic data); the results of the burnout questionnaire alone are presented in this paper. A total of 97 completed questionnaires were returned (representing a 28% response rate). The average score for emotional exhaustion was higher than the MBI norms, with 38% of respondents reporting emotional exhaustion (an element of burnout). The data presented support and validated a previous qualitative study, and highlighted key areas of concern requiring further study. A correlation between burnout and job dissatisfaction and intention to leave was identified; managers may want to consider encouraging role extension and good leadership qualities in treatment unit leaders to minimise the potential for burnout.

  9. Radiographic analysis of shoulder anatomical arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Merolla, Giovanni [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)], E-mail: gmerolla@shouldertech.it; Di Pietto, Francesco; Romano, Stefania [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, Naples (Italy); Paladini, Paolo; Campi, Fabrizio; Porcellini, Giuseppe [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)

    2008-10-15

    Arthroplasty is the standard treatment for advanced shoulder osteoarthritis. Modern prostheses designs have modular features whose size, shaft/head and body morphology can be adjusted. Total Shoulder Arthroplasty (TSA) provides better results. A complete X-ray follow-up is essential to assess the results and evaluate the survival rates of a shoulder prosthesis. Antero-posterior at 40 deg. in both internal and external rotation (true AP view) and axillary view are recommended to assess the following parameters: orientation and translation of the humeral component, offset, size and height of the humeral head, acromio-humeral distance, distribution and fixation of the cement, stress shielding and cortical resorption, radiolucent lines, subsidence and tilt, glenoid wear and 'bone stock', prostheses instability, glenoid component shift. Shoulder hemiarthroplasty can lead to glenoid wear; the true AP film at 40 deg. of internal rotation provides the best profile of gleno-humeral joint to depict glenoid erosion. Shift of the glenoid component in TSA is identified as tilting or medial migration on true AP and axillary views in the early postoperative period (1-2 months) and at minimum of 2 years. An exhaustive radiographic analysis remains essential to monitor the prosthetic implant and detect early and late complications or risk factors of prosthetic loosening.

  10. Projection angles of mandibular condyles in panoramic and transcranial radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Nah, Kyung Soo [Pusan National Univ. College of Dentistry, Pusan (Korea, Republic of)

    2006-09-15

    To evaluate the true projection angles of film-side mandibular condyles in panoramic and transcranial radiographs. 52 panoramic and transcranial radiographs of 4 condyles from two human dry mandibles with gradual horizontal and vertical angle changes were taken. The results were compared with the standard panoramic and transcranial radiographs and the identical pairs were selected. Panoramic radiography projected 10 degree to the film-sided condyles both horizontally and vertically. Transcranial radiography projected 15 degree to the film-sided condyles vertically. The medical and lateral poles were not forming the outline of condylar images in both projections when the horizontal angles of condyles were not sufficiently big enough.

  11. Radiographic artefact due to a faulty lead rubber shield

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, G. E-mail: gunasekarankumar@hotmail.com; Kamath, V.; Murali, S.R.; Temperley, D

    2003-05-01

    Radiographic examination is one of the commonest investigations performed in the field of Orthopaedics. There are several pitfalls to be kept in mind while interpreting radiographs in Orthopaedics. Bony or soft tissue lesions can be mimicked by anatomical variations, superimposition of soft tissues, inappropriate radiographic exposure and presence of external radio-opaque substances, to name a few. We present a case, where a faulty lead rubber shield mimicked a fracture of distal end of humerus. Early identification of these abnormalities can avoid distress to and unnecessary investigations of the patient.

  12. Contrast Enhancement of Radiographs Using Shift Invariant Wavelet Transform

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A novel approach using shift invariant wavelet transform is presented for the contrast enhancement of radiographs. By exploiting cross-scale correlation among wavelet coefficients, edge information of radiographic images is extracted and protected, while noise is smoothed out in the wavelet domain. Radiographs are then reconstructed from the transform coefficients modified at multi-scales by nonlinear enhancement operator. The method can achieve effectively contrast enhancement and edge-preserved denoising simultaneously, yet it is capable of giving visually distinct images and offering considerable benefits in medical diagnosis.

  13. Severe acute cholangitis after endoscopic sphincterotomy induced by barium examination: A case report

    Institute of Scientific and Technical Information of China (English)

    Zhen-Hai Zhang; Ya-Guang Wu; Cheng-Kun Qin; Zhong-Xue Su; Jian Xu; Guo-Zhe Xian; Shuo-DongWu

    2012-01-01

    Endoscopic sphincterotomy (EST) is considered as a possible etiological factor for severe cholangitis.We herein report a case of severe cholangitis after endoscopic sphincterotomy induced by barium examination.An adult male patient presented with epigastric pain was diagnosed as having choledocholithiasis by ultrasonography.EST was performed and the stone was completely cleaned.Barium examination was done 3d after EST and severe cholangitis appeared 4 h later.The patient was recovered after treated with tienam for 4 d.Barium examination may induce severe cholangitis in patients after EST,although rare,barium examination should be chosen cautiously.Cautions should be also used when EST is performed in patients younger than 50 years to avoid the damage to the sphincter of Oddi.

  14. Characterization and growth dynamics of barium titanate crystallite on nanometer scale

    Institute of Scientific and Technical Information of China (English)

    Sen Wang; Yue Zhang; Zhen Ji; Yousong Gu; Yunhua Huang; Cheng Zhou

    2005-01-01

    Barium titanate powder on nanometer scale was synthesized by means of co-precipitation. The thermal mass loss, crystal grain growth and phase transition of the barium titanate nanometer powder were investigated by TG (Thermogravimetric)-DTA (Differential scanning calorimetric) and XRD (X-ray powder diffractometer) at different heat treatment temperatures. The results show that amorphous barium titanate powder can transfer into tetragonal symmetry structure after heat treatment. When the heat treatment temperature is below 900℃, the grains grow rapidly because the activation energy at low temperature is greatly less than that at high temperature. By controlling theheat treatment temperature, the optimization of the barium titanate crystallite size and formation of tetragonal phase can be realized.

  15. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  16. Study of the immunoisolating effects of barium-alginate microencapsulation on rat islets allograft survival

    Institute of Scientific and Technical Information of China (English)

    Mei Zhang; Chao Liu; Cuiping Liu; Youwen Qin; Zhaosun Zhen

    2005-01-01

    Objective: To evaluate the immunoisolating effects of barium-alginate microencapsulation on islets allograft survival. Methods: The nonmicroencapsulated and microencapsulated islets were transplanted under the kidney capsule or intraperitoneally into Wistar rat with STZ-induced diabetes. The blood glucose and insulin secretion of grafts were observed. Graft function was tested by oral rats was associated with normal glucose and insulin profiles in response to OGTT. Conclusion: Microencapsulation with barium-alginate membrane can prolong islet survival and protect islets against allorejection.

  17. Synthesis of nonstoichiometric M-type barium ferrite nanobelt by spark plasma sintering method

    Institute of Scientific and Technical Information of China (English)

    ZHAO Wenyu; ZHANG Qingjie; TANG Xinfeng; CHENG Haibin

    2005-01-01

    This study investigated the feasibility of ultrafast crystallization of M-type barium ferrite when the coprecipitation precursors in stoichiometric proportions as BaFe12O19, Fe(OH)3 and BaCO3 nanoparticles, had been heated by spark plasma sintering (SPS) process. The results show that SPS method may realize the ultrafast crystallization of M-type barium ferrite, absolutely prevent the crystallization of intermediate phase α-Fe2O3, and significantly decrease the crystallization temperature of M-type barium ferrite. The sintered samples obtained at 800℃ by sintering the precursors for 10 minutes are a kind of multiphase ferrites composed of major phase M-type barium ferrite and trace amount of BaFe0.24Fe0.76O2.88. It is discovered that M-type barium ferrites in the holes of the sintered samples are in nanobelt microstructure about 100-300 nm in width and several micrometers in length. These M-type barium ferrite nanobelts are non-stoichiometric and may be expressed as BaFe12+Xo19+1.5x (-4.77≤x≤6.50). Their composistions suggest completely random Fe-rich or Ba-rich domains.

  18. Experimental studies on 3D printing of barium titanate ceramics for medical applications

    Directory of Open Access Journals (Sweden)

    Schult Mark

    2016-09-01

    Full Text Available The present work deals with the 3D printing of porous barium titanate ceramics. Barium titanate is a biocompatible material with piezoelectric properties. Due to insufficient flowability of the starting material for 3D printing, the barium titanate raw material has been modified in three different ways. Firstly, barium titanate powder has been calcined. Secondly, flow additives have been added to the powder. And thirdly, flow additives have been added to the calcined powder. Finally, a polymer has been added to the three materials and specimens have been printed from these three material mixtures. The 3D printed parts were then sintered at 1320°C. The sintering leads to shrinkage which differs between 29.51–71.53% for the tested material mixtures. The porosity of the parts is beneficial for cell growth which is relevant for future medical applications. The results reported in this study demonstrate the possibility to fabricate porous piezoelectric barium titanate parts with a 3D printer that can be used for medical applications. 3D printed porous barium titanate ceramics can especially be used as scaffold for bone tissue engineering, where the bone formation can be promoted by electrical stimulation.

  19. Radiographic findings in pulmonary hypertension from unresolved embolism

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-04-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms.

  20. Analyzing edge detection techniques for feature extraction in dental radiographs

    Directory of Open Access Journals (Sweden)

    Kanika Lakhani

    2016-09-01

    Full Text Available Several dental problems can be detected using radiographs but the main issue with radiographs is that they are not very prominent. In this paper, two well known edge detection techniques have been implemented for a set of 20 radiographs and number of pixels in each image has been calculated. Further, Gaussian filter has been applied over the images to smoothen the images so as to highlight the defect in the tooth. If the images data are available in the form of pixels for both healthy and decayed tooth, the images can easily be compared using edge detection techniques and the diagnosis is much easier. Further, Laplacian edge detection technique is applied to sharpen the edges of the given image. The aim is to detect discontinuities in dental radiographs when compared to original healthy tooth. Future work includes the feature extraction on the images for the classification of dental problems.

  1. Sarcoidosis: radiographic manifestations in the nails and distal phalanges

    Energy Technology Data Exchange (ETDEWEB)

    Albers, Brittany K.; Garner, Hillary W. [Mayo Clinic, Department of Radiology, Jacksonville, FL (United States); Sluzevich, Jason C. [Mayo Clinic, Department of Dermatology, Jacksonville, FL (United States)

    2016-05-15

    Sarcoidosis is a granulomatous disease which can affect multiple organ systems. Clinical and radiologic manifestations depend on the organ system involved and the chronicity of disease. Nail involvement in sarcoidosis is rare, but is clinically relevant as it indicates chronic systemic disease. Nail abnormalities can be identified radiographically, and when seen in patients with known or suspected sarcoidosis, should prompt careful evaluation of the underlying bone for osseous involvement. We describe a case of sarcoidosis with radiographic findings in the nails and distal phalangeal tufts, which were indicative of nail and osseous sarcoid involvement and strongly supported the presence of chronic systemic disease. Although the nail findings resolved clinically and on radiographs after treatment, the osseous findings showed only minimal improvement. To our knowledge, the radiographic findings of nail sarcoidosis have not been previously addressed in the literature. (orig.)

  2. Radiographic features of bisphosphonate therapy in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Grissom, L.E.; Theodore Harcke, H. [Dept. of Medical Imaging, Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Wilmington, DE (United States)

    2003-04-01

    Background: Pediatric patients are being treated with bisphosphonates for low bone mineral density. Skeletal radiographic findings have been described with bisphosphonates given orally and intravenously. Objective: To determine and describe the radiographic findings of cyclic intravenous bisphosphonate therapy in the growing skeleton. Materials and methods: Retrospective review of radiographs of 32 patients with osteogenesis imperfecta or cerebral palsy treated with intravenous bisphosphonates on a quarterly schedule. Results: Principal observations were metaphyseal bands and increased bone mineral density. The bands varied in spacing according to the age of the patient, rate of growth, and the location of the metaphysis. Fractures continued to be seen in patients with osteogenesis imperfecta. Conclusion: Cyclic bisphosphonate therapy results in distinctive radiographic findings in the growing skeleton. (orig.)

  3. Radiographic inspection and densitometric evaluation of CP-5 reactor fuel

    Energy Technology Data Exchange (ETDEWEB)

    Staroba, J. F.; Knoerzer, T. W.

    1978-02-01

    This report covers the radiographic and densitometric techniques used as part of a quality verification program for CP-5 reactor fuel by the Nondestructive Assay Section of the Special Materials Division. Other nondestructive tests used were ultrasonic and gamma-ray spectrometry. The main objectives were to perform a one-hundred percent radiographic inspection of the fuel tubes and to derive a quantitative relationship between fuel thickness and film density with the use of fabricated fuel step wedges. By the use of tangential x-ray techniques, measurements were made of fuel peaks or ''hot spots'' that protruded above the main fuel line. Other general problems in radiographic inspection and solutions for the upgrading of the total radiographic inspection program are also discussed.

  4. Optimization of pediatric chest radiographic images using optical densities ratio

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Rafael T.F.; Miranda, Jose R.A. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Inst. de Biociencias de Botucatu; Pina, Diana R. [Faculdade de Medicina de Botucatu (UNESP), Botucatu, SP (Brazil). Hospital das Clinicas. Dept. de Doencas Tropicais e Diagnostico por Imagem; Duarte, Sergio B. [Centro Brasileiro de Pesquisas Fisicas (CBPF/MCT), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The aim of this study is the optimization of radiographic images for the pediatric patients in the age range between 0 and 1 years old, through Optical Density Ratio (ODR), considering that pediatric patients are overexposed to radiation in the repeated attempts to obtain radiographic images considered of good quality. The optimization of radiographic techniques was carried out with the RAP-PEPP (Realistic Analytical Phantom coupled to homogeneous Phantom Equivalent to Pediatric Patient) phantom in two incubators and one cradle. The data show that the clinical routine radiographic techniques generate low-quality images at up to 18.8% when evaluated by the ODRs, and increases in doses up to 60% when compared to the optimized techniques doses. (author)

  5. Radiographic and scintigraphic evaluation of total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, R.; Soudry, M.

    1986-04-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic total knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent.

  6. A proposed benchmark for simulation in radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Jaenisch, G.-R.; Deresch, A.; Bellon, C. [Federal Institute for Materials Research and Testing Unter den Eichen 87, 12205 Berlin (Germany); Schumm, A.; Guerin, P. [EDF R and D, 1 avenue du Général de Gaulle, 92141 Clamart (France)

    2014-02-18

    The purpose of this benchmark study is to compare simulation results predicted by various models of radiographic testing, in particular those that are capable of separately predicting primary and scatter radiation for specimens of arbitrary geometry.

  7. Practical guidelines for radiographers to improve computed radiography image quality.

    Science.gov (United States)

    Pongnapang, N

    2005-10-01

    Computed Radiography (CR) has become a major digital imaging modality in a modern radiological department. CR system changes workflow from the conventional way of using film/screen by employing photostimulable phosphor plate technology. This results in the changing perspectives of technical, artefacts and quality control issues in radiology departments. Guidelines for better image quality in digital medical enterprise include professional guidelines for users and the quality control programme specifically designed to serve the best quality of clinical images. Radiographers who understand technological shift of the CR from conventional method can employ optimization of CR images. Proper anatomic collimation and exposure techniques for each radiographic projection are crucial steps in producing quality digital images. Matching image processing with specific anatomy is also important factor that radiographers should realise. Successful shift from conventional to fully digitised radiology department requires skilful radiographers who utilise the technology and a successful quality control program from teamwork in the department.

  8. Amyloidoma of the skull: pain radiographs, CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hidalgo, F. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Aguilera, C. [Inst. de Diagnostic per la Imatge (IDI), Centre Bellvitge, Hospital Duran i Reynals, Barcelona (Spain); Monford, J.L. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Rene, M. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Muntane, A. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Pons, L.C. [Inst. de Diagnostic per la Imatge (IDI), Centre Bellvitge, Hospital Duran i Reynals, Barcelona (Spain)

    1996-01-01

    Amyloidomas involving bone are rare. The 67-year-old man reported here had a large amyloidoma of the left frontal, parietal, sphenoid (greater wing) and temporal bones causing neural compression. Plain radiographs CT and MRI are shown. (orig.)

  9. High frame-rate digital radiographic videography

    Energy Technology Data Exchange (ETDEWEB)

    King, N.S.P.; Cverna, F.H.; Albright, K.L.; Jaramillo, S.A.; Yates, G.J.; McDonald, T.E. [Los Alamos National Lab., NM (United States); Flynn, M.J.; Tashman, S. [Henry Ford Health System, Detroit, MI (United States)

    1994-09-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100-microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  10. Pulmonary embolism findings on chest radiographs and multislice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Coche, Emmanuel; Goncette, Louis [Department of Radiology, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Verschuren, Franck [Department of Intensive Care and Emergency Medicine, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Hainaut, Philippe [Department of Internal Medicine, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium)

    2004-07-01

    Multislice spiral CT is becoming an increasingly important tool for diagnosing pulmonary embolism. However, in many instances, a chest radiograph is usually performed as a first-line examination. Many parenchymal, vascular, and other ancillary findings may be observed on both imaging modalities with a highly detailed depiction of abnormalities on multislice CT. A comprehensive review of chest radiograph findings is presented with side-by-side correlations of CT images reformatted mainly in the frontal plane. (orig.)

  11. Pulmonary embolism findings on chest radiographs and multislice spiral CT.

    Science.gov (United States)

    Coche, Emmanuel; Verschuren, Franck; Hainaut, Philippe; Goncette, Louis

    2004-07-01

    Multislice spiral CT is becoming an increasingly important tool for diagnosing pulmonary embolism. However, in many instances, a chest radiograph is usually performed as a first-line examination. Many parenchymal, vascular, and other ancillary findings may be observed on both imaging modalities with a highly detailed depiction of abnormalities on multislice CT. A comprehensive review of chest radiograph findings is presented with side-by-side correlations of CT images reformatted mainly in the frontal plane.

  12. Radiographic oral findings and death risk in the elderly

    OpenAIRE

    Soikkonen, K. (Kari)

    1999-01-01

    Abstract Radiographic oral and maxillofacial findings were recorded in a cohort of 293 home living elderly, in Helsinki, Finland, derived from a random sample of 8035 subjects, , born in 1904, 1909, and 1912, who participated in the Helsinki Ageing Study. They were 76, 81, and 86 years old at the commencement of the radiographic study. The relationships of potentially infectious findings with increased all-cause mortality over four years were studied. During the four-year...

  13. The 1980 ILO classification of radiographs of the pneumoconioses.

    Science.gov (United States)

    Shipley, R T

    1992-11-01

    The 1980 ILO classification of radiographs of the pneumoconioses has undergone revision and improvement in response to increases in knowledge and international concerns. Its goal is to standardize the reading and reporting of radiographic manifestations of the inhalation of dust so that international epidemiologic comparisons are possible. It remains an imperfect instrument, but "... although total elimination of variation is impossible, some measure of control can be achieved."

  14. Possibilty of the lower third molar eruption: Radiographic analysis

    OpenAIRE

    2006-01-01

    Backgraund/Aim. To assess the possibility of the eruption of the lower third molar on the basis of the measured parameters: retromolar space, mesiodistal crown width of a molar and the third molar angulation. Methods. The investigation included 104 patients both sexes (43 boys, and 61 girls), 16 to 25 years old (meanage, 18 years). It was performed using the orthopanthomographic radiographs analysis of those patients. Each radiograph was covered by tracing paper, and the contoures of the foll...

  15. Automatic detection of scoliotic curves in posteroanterior radiographs.

    Science.gov (United States)

    Duong, Luc; Cheriet, Farida; Labelle, Hubert

    2010-05-01

    Spinal deformities are diagnosed using posteroanterior (PA) radiographs. Automatic detection of the spine on conventional radiographs would be of interest to quantify curve severity, would help reduce observer variability and would allow large-scale retrospective studies on radiographic databases. The goal of this paper is to present a new method for automatic detection of spinal curves from a PA radiograph. A region of interest (ROI) is first extracted according to the 2-D shape variability of the spine obtained from a set of PA radiographs of scoliotic patients. This region includes 17 bounding boxes delimiting each vertebral level from T1 to L5. An adaptive filter combining shock with complex diffusion is used to individually restore the image of each vertebral level. Then, texture descriptors of small block elements are computed and submitted for training to support vector machines (SVM). Vertebral body's locations are thereby inferred for a particular vertebral level. The classifications of block elements for all 17 SVMs are identified in the image and a voting system is introduced to cumulate correctly predicted blocks. A spline curve is then fitted through the centers of the predicted vertebral regions and compared to a manual identification using a Student t-test. A clinical validation is performed using 100 radiographs of scoliotic patients (not used for training) and the detected spinal curve is found to be statistically similar (p < 0.05) in 93% of cases to the manually identified curve.

  16. Segmentation and determination of joint space width in foot radiographs

    Science.gov (United States)

    Schenk, O.; de Muinck Keizer, D. M.; Bernelot Moens, H. J.; Slump, C. H.

    2016-03-01

    Joint damage in rheumatoid arthritis is frequently assessed using radiographs of hands and feet. Evaluation includes measurements of the joint space width (JSW) and detection of erosions. Current visual scoring methods are timeconsuming and subject to inter- and intra-observer variability. Automated measurement methods avoid these limitations and have been fairly successful in hand radiographs. This contribution aims at foot radiographs. Starting from an earlier proposed automated segmentation method we have developed a novel model based image analysis algorithm for JSW measurements. This method uses active appearance and active shape models to identify individual bones. The model compiles ten submodels, each representing a specific bone of the foot (metatarsals 1-5, proximal phalanges 1-5). We have performed segmentation experiments using 24 foot radiographs, randomly selected from a large database from the rheumatology department of a local hospital: 10 for training and 14 for testing. Segmentation was considered successful if the joint locations are correctly determined. Segmentation was successful in only 14%. To improve results a step-by-step analysis will be performed. We performed JSW measurements on 14 randomly selected radiographs. JSW was successfully measured in 75%, mean and standard deviation are 2.30+/-0.36mm. This is a first step towards automated determination of progression of RA and therapy response in feet using radiographs.

  17. The first barium tin(II) bromide fluoride

    Science.gov (United States)

    Dénès, Georges; Merazig, Hocine; Muntasar, Abdualhafeed; Porterfield, Robyn

    2014-04-01

    In an effort to prepare barium tin(II) bromide fluorides for the first time, possibly similar to the chloride fluorides obtained earlier in our laboratory, precipitation reactions were carried out by mixing aqueous solutions of SnF2 and of BaBr2.2H2O. In contrast with the chloride fluoride system, a single powdered phase was obtained throughout the SnF2 - BaBr2 system, with the yield being maximum at X ≈ 0.25, where X is the molar fraction of barium bromide in the reaction mixture. Phase identification with the JCPDS database failed to produce a match, confirming that a new phase had been produced. The exact chemical composition of the new compound has not been obtained yet. Based on the X value for the maximum yield, the Sn/Ba ratio is likely to be 3/1 or 2/1. The Mössbauer spectrum at ambient conditions shows that bonding to tin(II) is covalent, therefore with the tin lone pair being stereoactive. The Mössbauer parameters ( δ = 3.68 mm/s, Δ = 0.99 mm/s) are similar to those of SnBrF and of Sn2BrF5, thereby showing that tin is bonded to both fluorine and bromine. The larger isomer shift and lower quadrupole splitting than in tin(II) fluorides show that the stereoactivity of the tin lone pair is lower than in the fluorides. The Mössbauer parameters fit well the linear correlation of the quadrupole splitting versus the isomer shift" that has been shown to be present in other series of tin(II) compounds. The linear decrease on this correlation shows that the contribution of non-spherical orbitals ( p and d) to the lone pair is a much larger contributor to the quadrupole splitting than lattice distortions. The structure is likely made of Ba2+ cations and tin(II) fluoride bromide polyatomic anions, with covalent bonding withinthe anions.

  18. Enthalpy of formation of (In, Gd)-doped barium cerate

    Energy Technology Data Exchange (ETDEWEB)

    Matskevich, N.I., E-mail: nata.matskevich@yandex.ru [Nikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, 630090 Novosibirsk (Russian Federation); Karlsruhe Institute of Technology, Institute of Solid State Physics, D-76334 Karlsruhe (Germany); Wolf, Th. [Karlsruhe Institute of Technology, Institute of Solid State Physics, D-76334 Karlsruhe (Germany); Adelmann, P.; Semerikova, A.N.; Anyfrieva, O.I. [Nikolaev Institute of Inorganic Chemistry, Siberian Branch of the Russian Academy of Sciences, 630090 Novosibirsk (Russian Federation)

    2015-09-10

    Highlights: • BaCe{sub 0.7}Gd{sub 0.2}In{sub 0.1}O{sub 2.85} was prepared by solid-state reaction. • The standard formation enthalpy was determined. • The stabilization energy (Δ{sub st}H°) was calculated. • Δ{sub st}H° of BaCe{sub 0.7}Gd{sub 0.2}In{sub 0.1}O{sub 2.85} is higher than BaCe{sub 0.7}Nd{sub 0.2}In{sub 0.1}O{sub 2.85} and BaCeO{sub 3}. - Abstract: Solution enthalpies of barium cerate doped by gadolinium and indium and a mixture of BaCl{sub 2} + 0.7CeCl{sub 3} + 2GdCl{sub 3} + 0.1InCl{sub 3} have been measured in 1 mol dm{sup −3} HCl with 0.1 mol dm{sup −3} KI. For the first time the standard molar formation enthalpy of BaCe{sub 0.7}Gd{sub 0.2}In{sub 0.1}O{sub 2.85} has been determined by solution calorimetry as follows: Δ{sub f}H° (298.15 K) = −1615.84 ± 9.01 kJ mol{sup −1}. The stabilization energy for above-mentioned compound has been calculated as well. It has been shown that barium cerate doped gadolinium and indium has higher stabilization energy than BaCe{sub 0.7}Nd{sub 0.2}In{sub 0.1}O{sub 2.85} and BaCeO{sub 3}. The reaction enthalpy with CO{sub 2} interaction has been calculated for BaCe{sub 0.7}Gd{sub 0.2}In{sub 0.1}O{sub 2.85}.

  19. Optimization of multiroute synthesis for polyaniline-barium ferrite composites

    Energy Technology Data Exchange (ETDEWEB)

    Ben Ghzaiel, Tayssir, E-mail: tayssir.ben-ghzaiel@satie.ens-cachan.fr [Université de Tunis El Manar Faculté des Sciences de Tunis, UR11ES18 Unité de Recherche de Chimie Minérale Appliquée, 2092, Tunis (Tunisia); SATIE, ENS Cachan, CNRS, Université Paris-Saclay, 61 av du Président Wilson, F-94230, Cachan (France); Dhaoui, Wadia [Université de Tunis El Manar Faculté des Sciences de Tunis, UR11ES18 Unité de Recherche de Chimie Minérale Appliquée, 2092, Tunis (Tunisia); Pasko, Alexander; Mazaleyrat, Frédéric [SATIE, ENS Cachan, CNRS, Université Paris-Saclay, 61 av du Président Wilson, F-94230, Cachan (France)

    2016-08-15

    A comparative study of physicochemical and magnetic properties of Polyaniline-BaFe{sub 12}O{sub 19} composites prepared by Solid-Based Polymerization (SBP) and by Aqueous-Based Polymerization (ABP) is carried out. The composites obtained by the latter method underwent a grinding to study the influence of shear stress. Thus, in a systematic approach, an investigation of stirring effect was done by synthesizing these composites using aqueous-based polymerization but without mechanical stirring. Different mass ratio of BaFe{sub 12}O{sub 19} was used to explore their impact on composites properties. X-ray diffraction, FTIR, SEM, TGA, conductivity and vibrating sample magnetometer measurements were performed. Structural and morphological investigations confirmed the presence of polyaniline and barium hexaferrite phase, which were in interaction in the composites regardless the polymerization route. The powder obtained by solid-based pathway revealed distinct particles with uniform distribution for various compositions (wt. %) of BaFe{sub 12}O{sub 19} in Pani, while the composites obtained by aqueous-based polymerization presented agglomerated nanostructures. Thermogravimetric analysis exhibited an improved thermal stability for Pani-BaFe{sub 12}O{sub 19} obtained by solid-based route. The electric conductivity has displayed decreasing trend of DC conductivity with the increase of BaFe{sub 12}O{sub 19} particles in the polymer matrix. Magnetic studies showed a ferromagnetic behaviour for all composites. The saturation magnetization monotonously increased with the increasing of BaFe{sub 12}O{sub 19} amount. The magnetic properties of the powders were mainly related to the hexaferrite loading which was determined using measured magnetic data. These results revealed that magnetization saturation was dependant of volume fraction of ferrite in the composites which was significantly affected by the reaction medium and mechanical stirring. The powders obtained by solid

  20. Defect Chemistry and Microstructure of Complex Perovskite Barium Zinc Niobate

    Science.gov (United States)

    Peng, Ping

    1991-02-01

    This dissertation presents a systematic study of the characterization of the phase transitions, microstructures, defects and transport properties of undoped and doped complex perovskite barium zinc niobate (BZN). Complex perovskite BZN is a paraelectric material while its parent material barium titanate is ferroelectric. With codoping of (Zn + 2Nb) into Ti site, BaTiO_3 shows three distinguished features. First, the Curie temperature is lowered; second, the three phase transitions (cubic-tetragonal-orthorhombic-rhombohedral) coalesce; and lastly, the transition becomes diffuse showing a typical 2nd order phase transition compared with 1st order in undoped BaTiO_3. Complex microchemical ordering is another characteristic of BZN. Stoichiometric BZN shows a mixture of two types of ordering schemes. 1:1, 1:2 ordered microdomains and the disordered matrix co-exist. The 1:1 type ordering involves an internal charge imbalance which inhibits the growth of 1:1 type of ordered microdomains. The 1:2 type ordering is consistent with the chemical composition of BZN. These ordering patterns can be modified by either adjustment of the Zn/Nb ratio or by doping. The defect structure of the stoichiometric BZN is closely related to that of BaTiO_3. Stoichiometric BZN is an insulator with wide band gap (~ 3.70 eV). Undoped BZN has a high oxygen vacancy concentration which comes from three possible sources, such as unavoidable acceptor impurities, due to their natural abundance, Zn/Nb ratio uncertainty due to processing limitations, and high temperature ZnO loss due to sintering process. The oxygen vacancy concentration for undoped BZN lays in the neighborhood of 1500 ppm (atm.). The compensation defects for various dopants have also been identified. Both electrons and holes conduct by a small polaron mechanism. Various thermodynamic parameters, such as enthalpies of oxidation and reduction, mass action constants for intrinsic electronic disorder, oxidation and reduction have been

  1. Mechanism of Phase Transformation and Formation of Barium Hexaferrite Doped with Rare-Earths in Sol-Gel Process

    Institute of Scientific and Technical Information of China (English)

    甘树才; 洪广言; 张军; 车平; 唐娟

    2003-01-01

    The phase-transformation in sol-gel preparation of barium hexaferrite and the formation of barium hexaferrite doped with La3+ were studied by chemical phase analysis, X-ray diffraction and infrared spectrometry analysis. The experimental results show that phase transformation reactions of FeCO3, Fe2O3 and BaFe2O4, barium hexaferrite and γ-Fe2O3 take place in the heat treatment of gel. While the doping lanthanide ion replace barium ion, an equivalent quantity of Fe3+ are reduced to Fe2+ to maintain the charge equilibrium.

  2. Dielectric and Impedance Spectroscopy of Barium Bismuth Vanadate Ferroelectrics

    Science.gov (United States)

    Sutar, B. C.; Choudhary, R. N. P.; Das, Piyush R.

    2014-07-01

    Structural, micro-structural and electrical properties of barium bismuth vanadate Ba(Bi0.5V0.5)O3 ceramics were investigated. X-ray diffraction (XRD) analysis of the prepared material confirmed the formation of the compound with monoclinic crystal system. Scanning electron microscopy (SEM) of the compound exhibits well-defined grains that are uniformly distributed throughout the surface of the sample. Dielectric properties of the compound were studied as a function of temperature at different frequencies. An observation of dielectric anomaly at 295 °C is due to ferroelectric phase transition that was later confirmed by the appearance of hysteresis loop. Detailed studies of complex impedance spectroscopy have provided a better understanding of the relaxation process and correlations between the microstructure-electrical properties of the materials. The nature of frequency dependence of ac conductivity obeys the Debye power law. The dc conductivity, calculated from the ac conductivity spectrum, shows the negative temperature coefficient of resistance behavior similar to that of a semiconductor.

  3. NLTE Strontium and Barium in metal poor red giant stars

    CERN Document Server

    Short, C I

    2006-01-01

    We present atmospheric models of red giant stars of various metallicities, including extremely metal poor (XMP, [Fe/H]<-3.5) models, with many chemical species, including, significantly, the first two ionization stages of Strontium (Sr) and Barium (Ba), treated in Non-Local Thermodynamic Equilibrium (NLTE) with various degrees of realism. We conclude that 1) for all lines that are useful Sr and Ba abundance diagnostics the magnitude and sense of the computed NLTE effect on the predicted line strength is metallicity dependent, 2) the indirect NLTE effect of overlap between Ba and Sr transitions and transitions of other species that are also treated in NLTE non-negligibly enhances NLTE abundance corrections for some lines, 3) the indirect NLTE effect of NLTE opacity of other species on the equilibrium structure of the atmospheric model is not significant, 4) the computed NLTE line strengths differ negligibly if collisional b-b and b-f rates are an order of magnitude smaller or larger than those calculated wi...

  4. On-line ultrasonic characterisation of barium doped lanthanum perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Thamilmaran, P.; Arunachalam, M. [Department of Physics, Sri SRNM College, Sattur 626203, Tamil Nadu (India); Research scholars in Physics, Manonmanium Sundaranar University, Tirunelveli 627012 Tamil Nadu (India); Sankarrajan, S. [Department of Physics, Unnamalai Institute of Technology, Kovilpatti 628503, Tamil Nadu (India); Sakthipandi, K., E-mail: sakthipandi@gmail.com [Department of Physics, Sethu Institute of Technology, Kariapatti 626115, Tamil Nadu (India)

    2015-06-15

    Perovskite manganite samples La{sub 1−x}Ba{sub x}MnO{sub 3} with the composition of x=0.30, 0.33 and 0.36 were prepared by employing solid state reaction technique. The X-ray diffraction (XRD) patterns confirmed the rhombhedral structure with R3c space group of the samples. The obtained energy dispersive analysis X-rays (EDX) spectra of the samples have confirmed the elemental composition of the samples. The scanning electron microscope (SEM) images of the samples were used to find out the size of the particles. In-situ ultrasonic measurements were carried out on the samples by through transmission method. The temperature dependence of the ultrasonic parameters revealed interesting features of the samples. The observed ultrasonic velocities and attenuation both in longitudinal and shear mode are related to the paramagnetic (PM) to ferromagnetic (FM) phase transition in the prepared samples. The results confirmed that an increase in the barium content in the sample leads to an increase in the phase transition temperature T{sub C}.

  5. Barium oxide, calcium oxide, magnesia, and alkali oxide free glass

    Science.gov (United States)

    Lu, Peizhen Kathy; Mahapatra, Manoj Kumar

    2013-09-24

    A glass composition consisting essentially of about 10-45 mole percent of SrO; about 35-75 mole percent SiO.sub.2; one or more compounds from the group of compounds consisting of La.sub.2O.sub.3, Al.sub.2O.sub.3, B.sub.2O.sub.3, and Ni; the La.sub.2O.sub.3 less than about 20 mole percent; the Al.sub.2O.sub.3 less than about 25 mole percent; the B.sub.2O.sub.3 less than about 15 mole percent; and the Ni less than about 5 mole percent. Preferably, the glass is substantially free of barium oxide, calcium oxide, magnesia, and alkali oxide. Preferably, the glass is used as a seal in a solid oxide fuel/electrolyzer cell (SOFC) stack. The SOFC stack comprises a plurality of SOFCs connected by one or more interconnect and manifold materials and sealed by the glass. Preferably, each SOFC comprises an anode, a cathode, and a solid electrolyte.

  6. Review on dielectric properties of rare earth doped barium titanate

    Science.gov (United States)

    Ismail, Fatin Adila; Osman, Rozana Aina Maulat; Idris, Mohd Sobri

    2016-07-01

    Rare earth doped Barium Titanate (BaTiO3) were studied due to high permittivity, excellent electrical properties and have wide usage in various applications. This paper reviewed on the electrical properties of RE doped BaTiO3 (RE: Lanthanum (La), Erbium (Er), Samarium (Sm), Neodymium (Nd), Cerium (Ce)), processing method, phase transition occurred and solid solution range for complete study. Most of the RE doped BaTiO3 downshifted the Curie temperature (TC). Transition temperature also known as Curie temperature, TC where the ceramics had a transition from ferroelectric to a paraelectric phase. In this review, the dielectric constant of La-doped BaTiO3, Er-doped BaTiO3, Sm-doped BaTiO3, Nd-doped BaTiO3 and Ce-doped BaTiO3 had been proved to increase and the transition temperature or also known as TC also lowered down to room temperature as for all the RE doped BaTiO3 except for Er-doped BaTiO3.

  7. Growth and characterization of barium oxide nanoclusters on YSZ(111)

    Energy Technology Data Exchange (ETDEWEB)

    Nachimuthu, Ponnusamy; Kim, Yong Joo; Kuchibhatla, Satyanarayana V N T; Yu, Zhongqing; Jiang, Weilin; Engelhard, Mark H.; Shutthanandan, V.; Szanyi, Janos; Thevuthasan, Suntharampillai

    2009-08-13

    Barium oxide (BaO) was grown on YSZ(111) substrate by oxygen-plasma-assisted molecular beam epitaxy (OPA-MBE). In-situ reflection high-energy electron diffraction, ex-situ x-ray diffraction, atomic force microscopy and x-ray photoelectron spectroscopy have confirmed that the BaO grows as clusters on YSZ(111). During and following the growth under UHV conditions, BaO remains in single phase. When exposed to ambient conditions, the clusters transformed to BaCO3 and/or Ba(OH)2 H2O. However, in a few attempts of BaO growth, XRD results show a fairly single phase cubic BaO with a lattice constant of 0.5418(1) nm. XPS results show that exposing BaO clusters to ambient conditions results in the formation BaCO3 on the surface and partly Ba(OH)2 throughout in the bulk. Based on the observations, it is concluded that the BaO nanoclusters grown on YSZ(111) are highly reactive in ambient conditions. The variation in the reactivity of BaO between different attempts of the growth is attributed to the cluster size.

  8. Colonic diverticulosis: evaluation with double contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jae Kook; Lee, Jong Koo; Yun, Eun Joo; Moon, Hee Jung; Shin, Hyun Ja [Korea Veterans Hospital, Seoul (Korea, Republic of)

    1997-02-01

    To evaluate the pattern of colonic diverticulosis according to age and sex, and recent trend. The authors retrospectively reviewed 120 cases of colonic diverticulosis in 1,020 patients who had undergone a double contrast barium enema examination between January 1st, 1993, and December 31st, 1995, and analyzed the frequency, size, multiplicity and anatomical site, according to age and sex. Diverticulum size was classified into one of three groups : less than 5mm, 5-10mm, over 10mm in diameter. The overall incidence of colonic diverticulosis was 120 cases among 1,020 patients(11.8%) with an incidence 5.3 times higher in males than in females. Peak incidence was in the fifth decade, with 19 cases (15.8%) among males, and after the sixth decade, with four cases(3.3%) among females. Mean age was 57.7 years. Diverticulum size of 5-10mm in diameter was predominant (2% of cases); average diameter was 5-6mm. The incidence of colonic diverticulosis was 5.1 times more frequent in the right colon (101 cases) than in the left (20 cases). The overall incidence of colonic diverticulosis has continually increased; in addition it has also recently increased slightly in left-sided colon. This is thought to be due to various factors, both congenital and acquired, including longer life with good health care, constipation, irritable bowel syndrome, stress and the tendency of eating patterns to more closely resemble those of the west.

  9. Sintering and foaming of barium silicate glass powder compacts

    Science.gov (United States)

    Mueller, Ralf; Reinsch, Stefan; Agea-Blanco, Boris

    2016-10-01

    The manufacture of sintered glasses and glass-ceramics, glass matrix composites and glass-bounded ceramics or pastes is often affected by gas bubble formation. Against this background, we studied sintering and foaming of barium silicate glass powders used as SOFC sealants using different powder milling procedures. Sintering was measured by means of heating microscopy backed up by XPD, DTA, Vacuum Hot Extraction (VHE) and optical and electron microscopy. Foaming increased significantly as milling progressed. For moderately milled glass powders, subsequent storage in air could also promote foaming. Although the powder compacts were uniaxially pressed and sintered in air, the milling atmosphere sig¬ni¬ficantly affected foaming. The strength of this effect increased in the order Ar ? N2 encapsulated CO2, even for powders milled in Ar and N2. Results of this study thus indicate that foaming is caused by carbonaceous species trapped on the glass powder surface. Foaming could be substantially reduced by milling in water and 10 wt% HCl.

  10. Abundance analysis of s-process enhanced barium stars

    CERN Document Server

    Mahanta, Upakul; Goswami, Aruna; Duorah, Kalpana

    2016-01-01

    Detailed chemical composition studies of stars with enhanced abundances of neutron-capture elements can provide observational constraints for neutron-capture nucleosynthesis studies and clues for understanding their contribution to the Galactic chemical enrichment. We present abundance results from high-resolution spectral analyses of a sample of four chemically peculiar stars characterized by s-process enhancement. High-Resolution spectra (R ~ 42000) of these objects spanning a wavelength range from 4000 to 6800 A, are taken from the ELODIE archive. We have estimated the stellar atmospheric parameters, the effective temperature T_eff, the surface gravity log g, and metallicity [Fe/H] from local thermodynamic equilibrium analysis using model atmospheres. We report estimates of elemental abundances for several neutron-capture elements, Sr, Y, Zr, Ba, La, Ce, Pr, Nd, Sm, Eu and Dy. While HD 49641 and HD 58368 show [Ba/Fe] > 1.16 the other two objects HD 119650 and HD 191010 are found to be mild barium stars wit...

  11. Crystallographic properties of magnetron sputtered barium ferrite films

    Energy Technology Data Exchange (ETDEWEB)

    Capraro, S. [Laboratoire DIOM, University of Saint-Etienne, 23 rue Michelon, 42023 Saint-Etienne Cedex (France)]. E-mail: stephane.capraro@univ-st-etienne.fr; Berre, M. Le [LPM, UMR 5511, INSA Lyon, 7 av. Jean Capelle, 69621 Villeurbanne Cedex (France); Chatelon, J.P. [Laboratoire DIOM, University of Saint-Etienne, 23 rue Michelon, 42023 Saint-Etienne Cedex (France); Bayard, B. [Laboratoire DIOM, University of Saint-Etienne, 23 rue Michelon, 42023 Saint-Etienne Cedex (France); Joisten, H. [CEA-LETI, 17 rue des martyrs, 38041 Grenoble Cedex (France); Canut, C. [LPMCN, University Lyon I, 43 Bvd. du 11 novembre 1918, 69622 Villerbanne, Cedex (France); Barbier, D. [LPM, UMR 5511, INSA Lyon, 7 av. Jean Capelle, 69621 Villeurbanne Cedex (France); Rousseau, J.J. [Laboratoire DIOM, University of Saint-Etienne, 23 rue Michelon, 42023 Saint-Etienne Cedex (France)

    2004-09-15

    The development of devices combining a ferrite with a semiconductor chip is a major focus of current research. Barium hexaferrite (BaFe{sub 12}O{sub 19} or BaM) thick films are deposited here using a RF magnetron sputtering system. Films are amorphous and non magnetic after deposition. Post-deposition thermal annealing is employed to make the films crystallize. The effects of the substrate, thermal annealing process, thickness, substrate temperature on crystallographic properties and stoichiometry are studied using a X-ray diffractometry (XRD) and Rutherford back-scattering (RBS). The in-depth homogeneity of Ba, Fe and O is evaluated by secondary ion mass spectroscopy (SIMS). The study shows a good crystallization of BaM films and there is a preferential orientation among the crystallographic planes (1 0 1), (2 0 0), (2 0 3), (1 0 2), (1 1 0) and (2 0 5) when BaM films are prepared at low RF power and when the substrate is heated. For several elaboration parameters, grains size is in the range of 25 and 40 nm and BaM films are stoichiometric with regard to the target stoichiometry.

  12. Sintering and foaming of barium silicate glass powder compacts

    Directory of Open Access Journals (Sweden)

    Ralf Mueller

    2016-10-01

    Full Text Available The manufacture of sintered glasses and glass-ceramics, glass matrix composites and glass-bounded ceramics or pastes is often affected by gas bubble formation. Against this background, we studied sintering and foaming of barium silicate glass powders used as SOFC sealants using different powder milling procedures. Sintering was measured by means of heating microscopy backed up by XPD, DTA, Vacuum Hot Extraction (VHE and optical and electron microscopy. Foaming increased significantly as milling progressed. For moderately milled glass powders, subsequent storage in air could also promote foaming. Although the powder compacts were uniaxially pressed and sintered in air, the milling atmosphere sig¬ni¬ficantly affected foaming. The strength of this effect increased in the order Ar  N2 < air < CO2. Conformingly, VHE studies revealed that the pores of foamed samples predominantly encapsulated CO2, even for powders milled in Ar and N2. Results of this study thus indicate that foaming is caused by carbonaceous species trapped on the glass powder surface. Foaming could be substantially reduced by milling in water and 10 wt% HCl.

  13. Combustion synthesis, characterization and luminescence properties of barium aluminate phosphor

    Institute of Scientific and Technical Information of China (English)

    AH Wako; FB Dejene; HC Swart

    2014-01-01

    The blue-green emitting Eu2+and Nd3+ doped polycrystalline barium aluminate (BaAl2O4:Eu2+,Nd3+) phosphor, was pre-pared by a solution-combustion method at 500 ºC without a post-annealing process. The characteristic variation in the structural and luminescence properties of the as-prepared samples was evaluated with regards to a change in the Ba/Al molar ratio from 0.1:1 to 1.4:1. The morphologies and the phase structures of the products were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), while the optical properties were investigated using ultra-violet (UV) and photoluminescence (PL) spectroscopy, respectively. The XRD and TEM results revealed that the average crystallite size of the BaAl2O4:Eu2+,Nd3+ phosphor was about 70 nm. The broad-band UV-excited luminescence of the phosphors was observed atλmax=500 nm due to transitions from the 4f65d1 to the 4f7 configuration of the Eu2+ ion. The PL results indi-cated that the main peaks in the emission and excitation spectrum of phosphor particles slightly shifted to the short wavelength due to the changes in the crystal field due to the structure changes caused by the variation in the quantity of the Ba ions in the host lattice.

  14. Enhanced photocatalytic hydrogen generation from barium tantalate composites.

    Science.gov (United States)

    Marschall, Roland; Soldat, Julia; Busser, G Wilma; Wark, Michael

    2013-04-01

    (111)-layered Ba5Ta4O15 photocatalysts were synthesised by a solid state reaction route and a citrate synthesis route, and their structural and electronic properties were investigated. After citrate route preparation, the presence of a second phase, namely Ba3Ta5O15, was determined by X-ray powder diffraction and absorption spectroscopy. The existence of this phase had a profound effect on the photocatalytic activity of this Ba5Ta4O15/Ba3Ta5O15 composite in comparison to the pure Ba5Ta4O15 materials. The photocatalytic performance of the barium tantalates was evaluated by investigating the capability in ˙OH radical formation and hydrogen generation. Strongly increased hydrogen evolution rates for the Ba5Ta4O15/Ba3Ta5O15 composite, up to 160% higher than for the pure Ba5Ta4O15, were determined, and only very small amounts of Rh co-catalyst, deposited on the photocatalysts by stepwise reductive photo-deposition, were needed to achieve these results.

  15. Abdominal actinomycosis: barium enema and computed tomography findings.

    Science.gov (United States)

    Uchiyama, N; Ishikawa, T; Miyakawa, K; Iinuma, G; Nakajima, H; Ushio, K; Yokota, T; Akasu, T; Shimoda, T

    1997-02-01

    A case of abdominal actinomycosis is described in a woman with recurrent right lower abdominal pain and low-grade fever without history of appendectomy. Past history included the use of an intrauterine device (IUD) until 10 years before manifestation of these symptoms. We followed up the patient, via diagnostic imaging, for 7 months. On initial barium enema, a polypoid lesion was visualized at the bottom of the cecum and there was constriction of the sigmoid colon; the appendix was not seen. Seven months later, poor extension at the cecum, severe constriction in the sigmoid colon, and narrowing of the terminal ileum were also visualized. On computed tomography (CT), the lesion was initially localized only in the ileocecal region adjacent to the sigmoid colon. After 7 months, the lesion had infiltrated adjacent anatomic components and showed direct infiltration of the pelvic space. Differential diagnosis was difficult, as it was not obvious whether this was a pelvic abscess due to inflammation or appendiceal carcinoma. Laparotomy was performed. Macroscopically, the lesion was not limited to the ileocecal region, but involved the right ureter, tubes the Fallopian and ovary, bladder, psoas muscle, and abdominal wall. Pathology findings showed, chronic inflammatory tissue with evidence of actinomycosis. Although previous reports have described a lack of specific findings in this disease. When actinomycosis is suspected, CT is recommended to define its extent.

  16. Rapid and accurate determination of barium by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Armelin, Maria Jose A.; Maihara, Vera A.; Saiki, Mitiko, E-mail: marmelin@ipen.br, E-mail: vmaihara@ipen.br, E-mail: mitiko@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Trevizam, Anderson R., E-mail: aanrt@hotmail.com [Universidade Estadual do Centro Oeste (UNICENTRO), Guarapuava, PR (Brazil)

    2013-07-01

    Barium is an alkaline earth metal naturally present in soils. When available at a high level in the soil it can cause toxicity to plants and animals. Not all the barium is readily available to living organisms. Inorganic and organic barium compounds can be presented as soluble or insoluble forms in the soil. The soluble form of BaS is extremely toxic to humans, animals and plants. Researchers have noted a decrease of K absorption in the plant when Ba concentrations are increased and a change in overall plant growth. In case of animals, Ba tends to be concentrated in the bones which may compete with calcium, although only about 2% barium ingested in dietary is absorbed by the body. Another effect is that the Ba can interfere with the availability of sulfur in the soil due to the sulphate formation of low solubility. Barium and some other elements are considered palioclimatic proxies. For some researchers, barite is perhaps the most appropriate indicator of paleoproductivity because of a high resistance to dissolution. As explained about the barium effects in various situations, it was considered important to study the more appropriated experimental conditions for determination of this element by INAA. Conditions established for this analysis were: a) Irradiation time, 15 and 40 seconds, under thermal flux neutron about 4 x 10{sup 12} n cm{sup -2} s{sup -1}, for determining barium in geological and biological matrices, respectively; b) Decay time, approximately of 4 minutes; c) Counting time of 30 minutes; d) Radionuclide measured {sup 139}Ba. The quality of Ba results was evaluated from the analysis of certified reference materials. The performance of the method was satisfactory, according to the criterion of E.ζ score. Results obtained in this study indicate INAA is a good alternative for Ba determination in geological and biological samples. (author)

  17. Gastrointestinal tract labeling for MDCT of abdomen: Comparison of low density barium and low density barium in combination with water

    Energy Technology Data Exchange (ETDEWEB)

    Gulati, Kavita; Shah, Zarine K.; Sainani, Nisha; Uppot, Raul; Sahani, Dushyant V. [Massachusetts General Hospital and Harvard Medical School, Department of Abdominal Imaging and Intervention, Boston, MA (United States)

    2008-05-15

    The purpose of the study was to compare the quality of stomach and small bowel marking/labeling using 1,350 ml of low-density barium alone (Volumen) with 900 ml of low-density barium and 450 ml of water for 16-MDCT scans of the abdomen and pelvis and assess cost benefits with the two protocols. In this IRB approved study, 80 consecutive patients scheduled for routine CECT (contrast-enhanced CT) of the abdomen-pelvis were studied. Patients were randomized into two groups and were administered either 1,350 ml of VoLumen (two bottles at 20-min intervals, one half bottle at 50 min and the last half on the table) or 900 ml of Volumen (two bottles at 20-min intervals and 450 ml water on the table). Portal venous phase scanning (detector collimation = 0.625 mm, speed = 18.75 mm, thickness = 5 mm) was subsequently performed. Images were reconstructed in axial and coronal plane at the CT console. Two blinded readers used a pre-designed template to assess distension and wall characteristics of the stomach and small bowel on a 5-point scale. Median scores with the two protocols were compared using the Wilcoxon rank sum test. The stomach and small bowel labeling was rated fair to optimal in all patients and did not differ significantly in the two protocols. The mean scores for distension of the small bowel and stomach were comparable. Inter-observer agreement for bowel labeling was found to be excellent (k 0.81). With the use of coronal images there was increased reader confidence in tracing the small bowel with both protocols. Acceptance for two bottles of Volumen and water was greater among patients as compared to three bottles of VoLumen. Use of two bottles of Volumen and water combination cost less than three bottles of Volumen. Stomach and small bowel labeling with administration of 900 ml of Volumen followed by 450 ml of water is cost effective and compares well to 1,350 ml of Volumen alone. (orig.)

  18. Radiographic dental implants recognition for geographic evaluation in human identification.

    Science.gov (United States)

    Nuzzolese, E; Lusito, S; Solarino, B; Di Vella, G

    2008-06-01

    Dental implants for prosthetic rehabilitation with fixed crown or mobile partial/total dentures is a very common oral treatment among the population in Italy as elsewhere. There is a great number of implant systems of different designs. However, a catalogue of radiographic images and a description of the dental implants available in Italy would be useful in order to identify the manufacturer and the type of implant encountered in forensic casework. When an unidentified body is found with one or more implants in the jaws, and no dental record is available, clues gleaned from the type of implants used could give direction to the investigation. In this study Italian implant manufactures were contacted and asked to provide specimen implants. Digital radiographs were taken of all the implants donated at 0º, 30º, and 60º horizontal rotation, combined with -20º, -10º, 0º, +10º, and +20º vertical inclination relative to the radiographic beam and the X-ray sensor. A total of 15 images per implant were taken and examined to identify consistent, unique features that would aid in implant recognition. Only those observations made from radiographs between -10º and +10º vertical inclination would ever be used for definite identification of any implant. The information from this study should be considered a survey of the commercial distribution of dental implants in Italy through their digital radiographic images. It is also a starting point for a wider geographical evaluation of different manufacturers in other countries and continents. The radiographic images provided should help both the forensic odontologist and the prosthodontist to identify pre-existing implants which they may discover from their radiographic images.

  19. The cost of screening radiographs after stable fracture fixation

    Science.gov (United States)

    Tufescu, Ted

    2017-01-01

    Background Currently up to 58% of Canadian surgeons would forego screening radiographs after stable fracture fixation. It is therefore expected that reducing screening radiographs will be well accepted, provided that patient safety is not compromised, resulting in a cost reduction. The study objective was to measure the savings of a simplified radiographic protocol for well-fixed fractures and establish feasibility for a noninferiority trial that proves patient safety. Methods Patients were randomized after fixation. The control group received screening radiographs immediately after fixation and at 2 weeks. The experimental group received radiographs only when clinically indicated. At 6 weeks all patients received radiographs. The cost of imaging, time spent in clinic and patient satisfaction was measured. A blinded reviewer documented adverse events, either detected or missed. Results Of the 90 patients screened, 39 were randomized and 26 had complete follow-up. The mean cost of radiographs over the first 6 weeks was $44.51 (95% confidence interval [CI] 38.64–50.38) per patient in the experimental group, and $129.23 (95% CI 120.23–138.23) in the control group (p The mean time spent in clinic at 2 weeks was 46 min (95% CI 32–60) per patient for the experimental group and 68 min (95% CI 55–81) for the control group (p = 0.018). Two complications occurred in the experimental group. Both were detected clinically and did not qualify as missed events. Conclusion Implementing a simplified radiography protocol after stable fracture fixation saves time and money. Additionally, no adverse events were missed with the study protocol. Recommendations are made toward a noninferiority trial to establish protocol safety. PMID:28234590

  20. Evaluation of the styloid process on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    More Chandramani

    2010-01-01

    Full Text Available Background: The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 - 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. Aim: To assess the styloid process on digital panoramic radiographs. Materials and Methods: The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. Results: The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Conclusion: Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin.

  1. 氯化钡除杂制取高纯氢氧化钡%Preparation of high purity barium hydroxide by impurity - removed barium chloride

    Institute of Scientific and Technical Information of China (English)

    翁贤芬; 毛逢银; 何琳; 李莉

    2009-01-01

    Removal technology of strontium and iron from crude barium chloride raw material were studied.Optimization of process conditions of strontium and iron removal were discussed.When crude barium chloride stiring and dissolving the mixture at 60 ℃ for 40 min,impurities of stromtium and calcuim can be removed and mass fraction of strontium in the obatined solid barium chloride was below 1×10-4.Then add oxydol (H2O2) at proportion of 100 g raw materials per 8 mL H2O2,and add active carbon and small quantity of sodium hydroxide.Finally,iron could be get rid of when pH was controlled below 10.Mass fraction of iron in barium hydroxide product was less than 1×10-5 when using the iron - removed barium chaloride as raw material.Therefore,purified barium chloride by this method can be used to produce purity barium hydroxide.%研究了粗氯化钡原料中锶和铁杂质的脱除工艺,探讨了脱除锶和铁的优化工艺条件.在粗氯化钡原料中加入去离子水,液固质量比为0.25: 1,在60 ℃下搅拌溶解40 min,可除去锶和钙杂质,所得氯化钡固体中锶质量分数低于1×10-4.在氯化钡溶液中加入双氧水,每100 g原料中加入双氧水8 mL,加入活性炭和少量氢氧化钠,控制pH低于10时,可除去铁杂质,用除铁后的氯化钡制取氢氧化钡,产品中铁质量分数低于1×10-5.用除杂后的氯化钡可制得高纯氢氧化钡.

  2. Positioning errors in digital panoramic radiographs: A study

    Directory of Open Access Journals (Sweden)

    A Cicilia Subbulakshmi

    2016-01-01

    Full Text Available Panoramic radiography is a unique and a very useful extraoral film technique that allows the dentist to view the entire dentition and related structures, from condyle to condyle, on one film. Capturing a wide range of structures on a single film grounds the odds of errors in the digital panoramic radiographs. Improper positioning of the patient complicates it more, reducing the diagnostic usefulness of these radiographs. Wide knowledge about the common positioning errors and the ways to rectify it benefits the dentists in interpretation and diagnosis. Aim: This study is aimed at analyzing the 10 common positional errors (anteriorly positioned, posteriorly positioned, head tilted upwards, head tilted downwards, head twisted to one side, head tipped, overlapping of spine in lower anterior region, tongue not placed close to palate, patient movement, and ghost images in 200 digital panoramic radiographs selected randomly. Materials and Methods: Two hundred digital panoramic radiographic images of the patients above 6 years of age were selected randomly from the stored data in the system, projected on the white screen, and studied. The radiographs were analyzed by two oral medicine and radiology specialists, by recording separately, and then the results were analyzed. Results: The most common error was failure to place the tongue close to the palate, which leads to the presence of radiolucent airspace obscuring the roots of the maxillary teeth.

  3. Digital image processing of mandibular trabeculae on radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Toshi

    1987-06-01

    The present study was aimed to reveal the texture patterns of the radiographs of the mandibular trabeculae by digital image processing. The 32 cases of normal subjects and the 13 cases of patients with mandibular diseases of ameloblastoma, primordial cysts, squamous cell carcinoma and odontoma were analyzed by their intra-oral radiographs in the right premolar regions. The radiograms were digitized by the use of a drum scanner densitometry method. The input radiographic images were processed by a histogram equalization method. The result are as follows : First, the histogram equalization method enhances the image contrast of the textures. Second, the output images of the textures for normal mandible-trabeculae radiograms are of network pattern in nature. Third, the output images for the patients are characterized by the non-network pattern and replaced by the patterns of the fabric texture, intertwined plants (karakusa-pattern), scattered small masses and amorphous texture. Thus, these results indicates that the present digital image system is expected to be useful for revealing the texture patterns of the radiographs and in the future for the texture analysis of the clinical radiographs to obtain quantitative diagnostic findings.

  4. [Transparency regime: semiotics of radiographical images in urological diagnostics].

    Science.gov (United States)

    Martin, M; Fangerau, H

    2012-10-01

    Shortly after Röntgen discovered x-rays urology became one of the main test fields for the application of this new technology. Initial scepticism among physicians, who were inclined to cling to traditional manual methods of diagnosing, was replaced by enthusiasm for radiographic technologies and the new method soon became the standard in, for example the diagnosis of concrements. Patients favoring radiographic procedures over the use of probes and a convincing documentation of stones in radiograms were factors that impacted the relatively rapid integration of radiology into urology. The radiographic representation of soft tissues and body cavities was more difficult and the development of contrast agents in particular posed a serious problem. Several patients died during this research. A new diagnostic dimension was revealed when radiography and cystography were combined to form the method of retrograde pyelography. However, the problem of how urologists could learn how to read the new images remained. In order to allow trainee physicians to practice interpreting radiograms atlases were produced which offered explanatory texts and drawings for radiographic images of the kidneys, the bladder etc. Thus, urologists developed a self-contained semiotics which facilitated the appropriation of a unique urological radiographical gaze.

  5. SURGICAL CROWN LENGTHENING: A 12-MONTH STUDY - RADIOGRAPHIC RESULTS*

    Science.gov (United States)

    Diniz, Daniela Eleutério; Okuda, Kalizia Marcela; Fonseca, Clarissa Ribeiro; Gonzalez, Marly Kimie Sonohara; Greghi, Sebastião Luiz Aguiar; do Valle, Accácio Lins; Lauris, José Roberto Pereira

    2007-01-01

    Objective The purpose of this study was to perform a radiographic follow-up evaluation after a 12-month healing period, following crown lengthening surgery. Material and methods Twenty-three periodontally healthy subjects (mean age 32.5 years) that required crown lengthening surgery in premolars were recruited. In a total of 30 premolars, full thickness flaps, osseous resection, and flap suturing were performed. The restorative margin was defined in the pre-surgical phase and maintained unaltered during the healing period, serving as a reference point. Standardized bitewing radiographs were taken before and after osseous reduction, and at 2, 3, 6, and 12-month healing periods. Results Intact lamina dura was observed at both mesial and distal alveolar crests only from the 3rd month. At 12-months, all alveolar crests presented lamina dura. The overall mean distance from the restorative margin to the alveolar crest achieved after osseous resection was 3.28±0.87 mm at mesial and 2.81±0.51 mm at distal sites. No significant radiographic changes in the bone crest were observed during a 12-month healing period. Conclusion The findings of this study suggest that the radiographic proximal bone level observed on bitewing radiographs following crown lengthening surgery can be used as a reference to predict the future level of the healed alveolar crest. PMID:19089145

  6. Etanercept for the treatment of non-radiographic axial spondyloarthritis.

    Science.gov (United States)

    Rios Rodriguez, Valeria; Poddubnyy, Denis

    2016-01-01

    Presently, tumor necrosis factor α antagonist therapy is the only effective alternative treatment to nonsteroidal anti-inflammatory drugs for the entire spectrum of axial spondyloarthritis, including non-radiographic and radiographic (=ankylosing spondylitis) forms. Recently, etanercept has been approved by the European Medicines Agency for the treatment of non-radiographic axial spondyloarthritis, increasing the number of available treatment options for this indication. The latest data on etanercept concerning clinical efficacy and safety in short-term and long-term treatment of patients with non-radiographic axial spondyloarthritis who do not respond to the first-line therapy with non-steroidal anti-inflammatory drugs suggests good efficacy and safety profiles similar to that observed previously in ankylosing spondylitis. This article reviews recent data on the efficacy and safety of etanercept and is focused on the treatment of non-radiographic axial spondyloarthritis. This article will also discuss the role of etanercept in the context of current and developing treatment options.

  7. Radiographic evaluation of the zygomatic air cell defect

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Hee; Lee, Soo Kyung; Park, Byeong Hyun; Son, Hyo Sun; Choi, Mi; Choi, Karp Shik [School of Dentistry, Kyungpook National University, Daegu (Korea, Republic of); An, Chang Hyeon [Korea Association of Health, (Korea, Republic of)

    2002-12-15

    The purpose of this study was to determine the prevalence, radiographic appearance, and characteristics of patients with zygomatic air cell defect (ZACD), and to give recommendations concerning radiographic evaluation and surgery. Routine panoramic radiographs of 1,400 patients admitted to the Kyungpook National University Hospital Dental Clinic, were retrospectively examined for the clinical and radiographic features of ZACD. ZACD was found in 31 cases, representing a prevalence of 2.2%. Patients with ZACD had a mean age of 27.5 years and a range of 9-52 years. Most ZACD cases were in their thirties. ZACD showed a strong male prediliction, 22 of the 31 subjects were males and 9 were females. Twenty-four cases of ZACD (77.4%) were unilateral, with the half occurring on the right side. In seven cases (22.6%), ZACD was bilateral. Twenty-six (68.4%) of the defects were of unilocular, while twelve (31.6%) of the defects were multilocular. Knowledge of ZACD may be helpful in interpreting images, including panoramic radiographs, in planning surgical treatment of the TMJ and in understanding the spread of pathological processes into the joint.

  8. Surgical crown lengthening: a 12-month study - radiographic results

    Directory of Open Access Journals (Sweden)

    Daniela Eleutério Diniz

    2007-08-01

    Full Text Available OBJECTIVE: The purpose of this study was to perform a radiographic follow-up evaluation after a 12-month healing period, following crown lengthening surgery. MATERIAL AND METHODS: Twenty-three periodontally healthy subjects (mean age 32.5 years that required crown lengthening surgery in premolars were recruited. In a total of 30 premolars, full thickness flaps, osseous resection, and flap suturing were performed. The restorative margin was defined in the pre-surgical phase and maintained unaltered during the healing period, serving as a reference point. Standardized bitewing radiographs were taken before and after osseous reduction, and at 2, 3, 6, and 12-month healing periods. RESULTS: Intact lamina dura was observed at both mesial and distal alveolar crests only from the 3rd month. At 12-months, all alveolar crests presented lamina dura. The overall mean distance from the restorative margin to the alveolar crest achieved after osseous resection was 3.28±0.87 mm at mesial and 2.81±0.51 mm at distal sites. No significant radiographic changes in the bone crest were observed during a 12-month healing period. CONCLUSION: The findings of this study suggest that the radiographic proximal bone level observed on bitewing radiographs following crown lengthening surgery can be used as a reference to predict the future level of the healed alveolar crest.

  9. Radiographic adenoid evaluation: proposal of an objective parameter

    Directory of Open Access Journals (Sweden)

    Murilo Fernando Neuppmann Feres

    2014-04-01

    Full Text Available Objective The objective of the present study was to evaluate current radiographic parameters designed to investigate adenoid hypertrophy and nasopharyngeal obstruction, and to present an alternative radiographic assessment method. Materials and Methods In order to do so, children (4 to14 years old who presented with nasal obstruction or oral breathing complaints were submitted to cavum radiographic examination. One hundred and twenty records were evaluated according to quantitative radiographic parameters, and data were correlated with a gold-standard videonasopharyngoscopic study, in relation to the percentage of choanal obstruction. Subsequently, a regression analysis was performed in order to create an original model so the percentage of the choanal obstruction could be predicted. Results The quantitative parameters demonstrated moderate, if not weak correlation with the real percentage of choanal obstruction. The regression model (110.119*A/N demonstrated a satisfactory ability to “predict” the actual percentage of choanal obstruction. Conclusion Since current adenoid quantitative radiographic parameters present limitations, the model presented by the present study might be considered as an alternative assessment method in cases where videonasopharyngoscopic evaluation is unavailable.

  10. Barium Tagging in Solid Xenon for the nEXO Experiment

    Science.gov (United States)

    Chambers, Christopher; Craycraft, Adam; Walton, Timothy; Fairbank, William; nEXO Collaboration

    2016-09-01

    The proposed nEXO experiment utilizes a tonne-scale liquid xenon time projection chamber to search for neutrinoless double beta decay in xenon-136. Positive observation of this decay would determine the nature of the neutrino to be a MAJORANA particle, as well as measure the absolute neutrino mass scale. A critical concern for any rare decay search is reducing or eliminating backgrounds that cannot be distinguished from signal. A powerful background discrimination technique is positive identification of the daughter atom of the decay, in this case barium. This technique, called ``barium tagging'' may be available for a second phase of nEXO operation, allowing for neutrino mass sensitivity beyond the inverted mass hierarchy. Development is underway on a scheme to capture the barium daughter in solid xenon with a cryogenic probe and detect the barium by laser-induced fluorescence inside the solid xenon sample. This presentation reports results on imaging of single barium atoms frozen in a solid xenon matrix, as well as the progress on the freezing and removal of a solid xenon sample from liquid xenon. Graduated.

  11. Fabrication of barium/strontium carbonate coated amorphous carbon nanotubes as an improved field emitter

    Science.gov (United States)

    Maity, S.; Jha, A.; Das, N. S.; Chattopadhyay, K. K.

    2013-02-01

    Amorphous carbon nanotubes (aCNTs) were synthesized by a chemical reaction between ferrocene and ammonium chloride at a temperature ˜250 ∘C in an air furnace. As-synthesized aCNTs were coated with the barium/strontium carbonate through a simple chemical process. The coating of barium/strontium carbonate was confirmed by a high resolution transmission electron microscopy, X-ray diffraction, and Fourier transformed infrared spectroscopy. Morphology of the as-prepared samples was studied by field emission scanning electron microscopy. Thermal gravimetric analysis showed that barium/strontium carbonate coated aCNTs are more stable than the pristine aCNTs. As-prepared barium/strontium carbonate coated aCNTs showed significantly improved field emission properties with a turn-on field as low as 2.5 V/μm. The variation of field emission characteristics of the barium/strontium carbonate coated aCNTs with interelectrode distances was also studied.

  12. Determination of barium in surface and ground waters at Centro Experimental Aramar area

    Energy Technology Data Exchange (ETDEWEB)

    Matoso, Erika, E-mail: ematoso@hotmail.com [Centro Tecnologico da Marinha em Sao Paulo (CEA/CTMS), Ipero, SP (Brazil). Centro Experimental Aramar; Cadore, Solange, E-mail: cadore@iqm.unicamp.br [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Instituto de Quimica. Departamento de Quimica Analica

    2015-07-01

    Barium can be found in waters up to 1 mg L{sup -1} and came from natural sources such as sedimentary rocks erosion rich in feldspar and barite. Also anthropogenic activities can release this element such as oil and gas industry, agricultural defensives, chemical industry and waste disposal. At high doses, barium can be harmful to human central nervous system and can also cause high blood pressure, heart problems, fatigue and anxiety. The water potability defined by Brazilian's Ministry of Healthy sets barium concentration up to 0.7 mg L{sup -1} and official regulation defines the same limit of this element to superficial waters (according CONAMA resolution 357/2005) and ground waters (Sao Paulo state regulation). In this work, barium was analyzed monthly in superficial waters from 4 different sampling locations, located in a ratio of 10-km-long from Centro Experimental Aramar (CEA) at Ipanema River, during one year, in order to evaluate the river in different conditions (seasons, temperature and rain period). The ground water was collected every six months. The analytical technique applied was ICP OES and the method conditions were optimized: wavelength, linearity, signal background ratio, detection and quantification limits. Data obtained in this work will contribute to evaluate the presence of barium at CEA region and nearby in order to compare it with current Brazilian regulations. (author)

  13. SALT reveals the barium central star of the planetary nebula Hen 2-39

    CERN Document Server

    Miszalski, B; Jones, D; Karakas, A I; Köppen, J; Tyndall, A A; Mohamed, S S; Rodríguez-Gil, P; Santander-García, M

    2013-01-01

    Classical barium stars are binary systems which consist of a late-type giant enriched in carbon and slow neutron capture (s-process) elements and an evolved white dwarf (WD) that is invisible at optical wavelengths. The youngest observed barium stars are surrounded by planetary nebulae (PNe), ejected soon after the wind accretion of polluted material when the WD was in its preceeding asymptotic giant branch (AGB) phase. Such systems are rare but powerful laboratories for studying AGB nucleosynthesis as we can measure the chemical abundances of both the polluted star and the nebula ejected by the polluter. Here we present evidence for a barium star in the PN Hen 2-39. The polluted giant is very similar to that found in WeBo 1. It is a cool (Teff=4250 +/- 150 K) giant enhanced in carbon ([C/H]=0.42 +/- 0.02 dex) and barium ([Ba/Fe]=1.50 +/- 0.25 dex). A spectral type of C-R3 C_24 nominally places Hen 2-39 amongst the peculiar early R-type carbon stars, however the barium enhancement and likely binary status mea...

  14. Differentiating Pneumothorax from the Common Radiographic Skinfold Artifact.

    Science.gov (United States)

    Kattea, M Obadah; Lababede, Omar

    2015-06-01

    Pneumothorax can be a critical medical condition. The radiographic curvilinear appearance of pneumothorax can be mimicked by a skinfold artifact. Radiographic differentiation of the two entities is achieved in most cases by careful analysis of the characteristics of the linear shadow and its course. A thin, sharply defined opaque density representing the visceral pleura is the hallmark of pneumothorax. The added density of a skinfold presents as a broad opacity, which is outlined laterally by a sharply defined lucent line as a result of the Mach band effect and adjacent air. Unlike pneumothorax, a skinfold produces a line that does not follow the expected course of visceral pleura. Additional features, such as the absence of increased lucency laterally and the projection of lung markings across the curvilinear shadow, can help in the correct identification of skinfolds. Repeating the chest radiograph or using other imaging modalities can be considered in difficult cases.

  15. Standard specification for illuminators used for viewing industrial radiographs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 The function of the illuminator is to provide sufficient illumination and viewing capabilities for the purpose of identification and interpretation of radiographic images. This specification provides the recommended minimum requirements for Industrial Radiographic Illuminators used for viewing industrial radiographic films using transmitted light sources. 1.2 The illuminator has to ensure the same safety for personnel, or users of any electric apparatus, as specified by electrical standards applicable in the country in which the illuminator is used. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 Values stated in SI units are to be regarded as the standard. The values given in parenthesis are provided for information only.

  16. Comparisons of NIF convergent ablation simulations with radiograph data.

    Science.gov (United States)

    Olson, R E; Hicks, D G; Meezan, N B; Koch, J A; Landen, O L

    2012-10-01

    A technique for comparing simulation results directly with radiograph data from backlit capsule implosion experiments will be discussed. Forward Abel transforms are applied to the kappa*rho profiles of the simulation. These provide the transmission ratio (optical depth) profiles of the simulation. Gaussian and top hat blurs are applied to the simulated transmission ratio profiles in order to account for the motion blurring and imaging slit resolution of the experimental measurement. Comparisons between the simulated transmission ratios and the radiograph data lineouts are iterated until a reasonable backlighter profile is obtained. This backlighter profile is combined with the blurred, simulated transmission ratios to obtain simulated intensity profiles that can be directly compared with the radiograph data. Examples will be shown from recent convergent ablation (backlit implosion) experiments at the NIF.

  17. Early diagnosis of atherosclerosis with panoramic radiographs: a review

    Directory of Open Access Journals (Sweden)

    Daiane Landim Borba

    Full Text Available Abstract Carotid artery disease has been linked with cerebral vascular accident, also known as stroke, cerebral hemorrhage, or cerebral ischemia. It is caused by narrowing or obstruction of arteries in the neck (the carotid arteries that are responsible for transporting blood from the aorta to the brain. Panoramic radiographs are used in dentistry to show both dental arches as a supplement to the clinical dental examination. The objective of this study is to highlight the importance of panoramic radiographs for diagnosis of arterial disease, by means of a bibliographic review. The PubMed database was searched using the keywords “atherosclerosis” and “panoramic”, with the filters “last 5 years” and “humans”. Twenty articles were identified, six of which were chosen for this study because they were open access. The review concluded that panoramic radiographs enable early diagnosis of carotid artery calcification, resulting in earlier interventions, and offer an accessible cost.

  18. Rotator cuff tears: clinical, radiographic, and US findings.

    Science.gov (United States)

    Moosikasuwan, Josh B; Miller, Theodore T; Burke, Brian J

    2005-01-01

    Rotator cuff tears are a common cause of shoulder pain. Clinical and radiographic findings can suggest the presence of a rotator cuff tear. The most sensitive clinical findings are impingement and the "arc of pain" sign. Radiographic findings are usually normal in the acute setting, although the "active abduction" view may show decreased acromiohumeral distance. In more chronic cases, an outlet view may show decreased opacity and decreased size of the supraspinatus muscle due to atrophy. In late cases, the humeral head may become subluxated superiorly, and secondary degenerative arthritis of the glenohumeral joint may ensue. Ultrasonography (US), with over 90% sensitivity and specificity, can help confirm the diagnosis in clinically or radiographically equivocal cases. US can also reveal the presence of other abnormalities that may mimic rotator cuff tear at clinical examination, including tendinosis, calcific tendinitis, subacromial subdeltoid bursitis, greater tuberosity fracture, and adhesive capsulitis.

  19. Sputtered Modified Barium Titanate for Thin-Film Capacitor Applications

    Directory of Open Access Journals (Sweden)

    Robert Mamazza

    2012-04-01

    Full Text Available New apparatus and a new process for the sputter deposition of modified barium titanate thin-films were developed. Films were deposited at temperatures up to 900 °C from a Ba0.96Ca0.04Ti0.82Zr0.18O3 (BCZTO target directly onto Si, Ni and Pt surfaces and characterized by X-ray diffraction (XRD, scanning electron microscopy (SEM and X-ray photoelectron spectroscopy (XPS. Film texture and crystallinity were found to depend on both deposition temperature and substrate: above 600 °C, the as-deposited films consisted of well-facetted crystallites with the cubic perovskite structure. A strongly textured Pt (111 underlayer enhanced the (001 orientation of BCZTO films deposited at 900 °C, 10 mtorr pressure and 10% oxygen in argon. Similar films deposited onto a Pt (111 textured film at 700 °C and directly onto (100 Si wafers showed relatively larger (011 and diminished intensity (00ℓ diffraction peaks. Sputter ambients containing oxygen caused the Ni underlayers to oxidize even at 700 °C: Raising the process temperature produced more diffraction peaks of NiO with increased intensities. Thin-film capacitors were fabricated using ~500 nm thick BCZTO dielectrics and both Pt and Ni top and bottom electrodes. Small signal capacitance measurements were carried out to determine capacitance and parallel resistance at low frequencies and from these data, the relative permittivity (er and resistivity (r of the dielectric films were calculated; values ranged from ~50 to >2,000, and from ~104 to ~1010 Ω∙cm, respectively.

  20. Evaluation of antibacterial properties of Barium Zirconate Titanate (BZT nanoparticle

    Directory of Open Access Journals (Sweden)

    Simin Mohseni

    2014-12-01

    Full Text Available So far, the antibacterial activity of some organic and inorganic compounds has been studied. Barium zirconate titanate [Ba(Zr xTi1-xO3] (x = 0.05 nanoparticle is an example of inorganic materials. In vitro studies have provided evidence for the antibacterial activity of this nanoparticle. In the current study, the nano-powder was synthesized by sol-gel method. X-ray diffraction showed that the powder was single-phase and had a perovskite structure at the calcination temperature of 1000 ºC. Antibacterial activity of the desired nanoparticle was assessed on two gram-positive (Staphylococcus aureus PTCC1431 and Micrococcus luteus PTCC1625 and two gram-negative (Escherichia coli HP101BA 7601c and clinically isolated Klebsiella pneumoniae bacteria according to Radial Diffusion Assay (RDA. The results showed that the antibacterial activity of BZT nano-powder on both gram-positive and gram-negative bacteria was acceptable. The minimum inhibitory concentration of this nano-powder was determined. The results showed that MIC values for E. coli, K. pneumoniae, M. luteus and S. aureus were about 2.3 µg/mL, 7.3 µg/mL, 3 µg/mL and 12 µg/mL, respectively. Minimum bactericidal concentration (MBC was also evaluated and showed that the growth of E. coli, K. pneumoniae, M. luteus and S. aureus could be decreased at 2.3, 14, 3 and 18 µg/mL of BZT. Average log reduction in viable bacteria count in time-kill assay ranged between 6 Log10 cfu/mL to zero after 24 h of incubation with BZT nanoparticle.

  1. Dose optimisation of double-contrast barium enema examinations.

    Science.gov (United States)

    Berner, K; Båth, M; Jonasson, P; Cappelen-Smith, J; Fogelstam, P; Söderberg, J

    2010-01-01

    The purpose of the present work was to optimise the filtration and dose setting for double-contrast barium enema examinations using a Philips MultiDiagnost Eleva FD system. A phantom study was performed prior to a patient study. A CDRAD phantom was used in a study where copper and aluminium filtration, different detector doses and tube potentials were examined. The image quality was evaluated using the software CDRAD Analyser and the phantom dose was determined using the Monte Carlo-based software PCXMC. The original setting [100 % detector dose (660 nGy air kerma) and a total filtration of 3.5 mm Al, at 81 kVp] and two other settings identified by the phantom study (100 % detector dose and additional filtration of 1 mm Al and 0.2 mm Cu as well as 80 % detector dose and added filtration of 1 mm Al and 0.2 mm Cu) were included in the patient study. The patient study included 60 patients and up to 8 images from each patient. Six radiologists performed a visual grading characteristics study to evaluate the image quality. A four-step scale was used to judge the fulfillment of three image quality criteria. No overall statistical significant difference in image quality was found between the three settings (P > 0.05). The decrease in the effective dose for the settings in the patient study was 15 % when filtration was added and 34 % when both filtrations was added and detector dose was reduced. The study indicates that additional filtration of 1 mm Al and 0.2 mm Cu and a decrease in detector dose by 20 % from the original setting can be used in colon examinations with Philips MultiDiagnost Eleva FD to reduce the patient dose by 30 % without significantly affecting the image quality. For 20 exposures, this corresponds to a decrease in the effective dose from 1.6 to 1.1 mSv.

  2. Osteosarcoma; clinical aspects and significance of conventional radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Jin Suck; Kim, Eung Jo; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    The clinical features of 141 patients with osteosarcoma were analysed and conventional radiographs of 92 patients out of 141 patients were reviewed retrospectively in order to assess the distribution of the age, sex, locations and to evaluate the predominant radiographic features. The incidence of tumors occurring in the extremities is 90 percent of total 141 patients. The majority of tumors were located in the metaphases of the long tubular bones. About sixty percent of the patients were in the second decade of life. The increment of the level of serum alkaline phosphatase was observed in 76 (67%) out of 114 patients. It is considered that thoracic CT scan might be helpful for the evaluation of metastases to lungs, because the detection rate of lung metastasis was 20 percent among 30 cases by CT, being disclosed higher than by conventional radiographs. Of the 92 patients available for radiographic analysis, predominantly osteolytic lesions were disclosed in 17 cases (19%). Preoperative radiographic impression was not the osteosarcoma in 8 out of 17 patients with purely osteolytic osteosarcoma. It was meant that the radiographic diagnosis was difficult in each case of predominantly osteolytic lesions. The patterns of periosteal reaction were variable, and there was no evidence of periosteal reaction in seventeen patients (18%). Both the cortical destruction and, the intralesional calcification were observed in 85 percent of 92 patients with osteosarcoma. Extraskeletal tumor shadow was observed in 79 percent of 92 patients with osteosarcoma, but either the calcification of ossification was detected in only 55 patients among 73 patients with soft tissue tumor shadows. Only 7 patients had a pathologic fracture, all in the femur.

  3. Radiographic Classification of Developmental Dysplasia of the Hip

    Directory of Open Access Journals (Sweden)

    José Julio Requeiro Molina

    2013-08-01

    Full Text Available For over a decade, abduction splinting has been the method of treatment for developmental dysplasia of the hip in the Paquito González Cueto University Pediatric Hospital. This paper is aimed at presenting the dynamic classification for this condition from a radiographic point of view. Representative schemes and radiographies of patients with various stages of developmental hip dysplasia were used for illustrating this classification. The dynamic behavior of the radiographic parameters used in the classification allows gathering diagnostic groups before, during and after treatment in order to assess its final results.

  4. Theoretical analysis of radiographic images by nonstationary Poisson processes

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, K.; Uchida, S. (Gifu Univ. (Japan)); Yamada, I.

    1980-12-01

    This paper deals with the noise analysis of radiographic images obtained in the usual fluorescent screen-film system. The theory of nonstationary Poisson processes is applied to the analysis of the radiographic images containing the object information. The ensemble averages, the autocorrelation functions, and the Wiener spectrum densities of the light-energy distribution at the fluorescent screen and of the film optical-density distribution are obtained. The detection characteristics of the system are evaluated theoretically. Numerical examples one-dimensional image are shown and the results are compared with those obtained under the assumption that the object image is related to the background noise by the additive process.

  5. Theoretical Analysis of Radiographic Images by Nonstationary Poisson Processes

    Science.gov (United States)

    Tanaka, Kazuo; Yamada, Isao; Uchida, Suguru

    1980-12-01

    This paper deals with the noise analysis of radiographic images obtained in the usual fluorescent screen-film system. The theory of nonstationary Poisson processes is applied to the analysis of the radiographic images containing the object information. The ensemble averages, the autocorrelation functions, and the Wiener spectrum densities of the light-energy distribution at the fluorescent screen and of the film optical-density distribution are obtained. The detection characteristics of the system are evaluated theoretically. Numerical examples of the one-dimensional image are shown and the results are compared with those obtained under the assumption that the object image is related to the background noise by the additive process.

  6. Clinical history and physical examination skills - A requirement for radiographers?

    Energy Technology Data Exchange (ETDEWEB)

    Snaith, Beverly A. [Radiology Department, Mid Yorkshire Hospitals NHS Trust, Pinderfields General Hospital, Aberford Road, Wakefield WF1 4DG (United Kingdom)], E-mail: bev.snaith@midyorks.nhs.uk; Lancaster, Anne [Radiology Department, Mid Yorkshire Hospitals NHS Trust, Dewsbury District Hospital, Halifax Road, Dewsbury WF13 4HS (United Kingdom)

    2008-05-15

    Radiographer's roles have evolved with their scope broadening over the last 20 years culminating in the development of advanced and consultant posts. Yet one development has not been embraced, despite being inherent in medicine and a common extension of nurse and other allied health professionals' roles, is that of clinical assessment. This article explores the evolving role of the radiographer and discusses whether this should include skills in clinical history taking and physical examination. Issues for education and development will be addressed together with examples of current and potential roles.

  7. Radiographic kidney measurements in captive cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Hackendahl, Nicole C; Citino, Scott B

    2005-06-01

    The prevalence of chronic renal disease is substantial among captive cheetahs (Acinonyx jubatus). The purpose of this study was to determine kidney measurements from radiographs of captive cheetahs (n = 15) with normal renal function. The ratio of kidney length to length of the body of the second lumbar vertebrae has been established for domestic cats with normal renal function. The mean ratio of renal length to length of the second lumbar vertebra was 1.81 +/- 0.14 in cheetahs. This baseline data may allow an objective evaluation of radiographic kidney size in cheetahs. However, evaluation of a small number of cheetahs with confirmed renal failure resulted in a similar ratio.

  8. Automated thresholding in radiographic image for welded joints

    Science.gov (United States)

    Yazid, Haniza; Arof, Hamzah; Yazid, Hafizal

    2012-03-01

    Automated detection of welding defects in radiographic images becomes non-trivial when uneven illumination, contrast and noise are present. In this paper, a new surface thresholding method is introduced to detect defects in radiographic images of welding joints. In the first stage, several image processing techniques namely fuzzy c means clustering, region filling, mean filtering, edge detection, Otsu's thresholding and morphological operations method are utilised to locate the area in which defects might exist. This is followed by the implementation of inverse surface thresholding with partial differential equation to locate isolated areas that represent the defects in the second stage. The proposed method obtained a promising result with high precision.

  9. Calcifying aponeurotic fibroma: Case report with radiographic and MR features

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Hwa; Kim, Yeon Mee [Inje University College of Medicine, Haeundae Paik Hospital, Busan (Korea, Republic of)

    2014-02-15

    Calcifying aponeurotic fibroma is a rare, benign fibroblastic tumor. The lesion has a propensity for local invasion and a high recurrent rate. Therefore, accurate preoperative diagnosis and complete excision are important to prevent the recurrence of the tumor after surgical removal. However, radiographic and magnetic resonance imaging findings of calcifying aponeurotic fibroma have been extremely rarely described in the radiology literature. Thus, we report a rare case of calcifying aponeurotic fibroma affecting the dorsal wrist in a 67-year-old man, describe radiographic and MR findings, and discuss the differential diagnosis of the tumor.

  10. Calcifying aponeurotic fibroma: case report with radiographic and MR features.

    Science.gov (United States)

    Kim, Ok Hwa; Kim, Yeon Mee

    2014-01-01

    Calcifying aponeurotic fibroma is a rare, benign fibroblastic tumor. The lesion has a propensity for local invasion and a high recurrent rate. Therefore, accurate preoperative diagnosis and complete excision are important to prevent the recurrence of the tumor after surgical removal. However, radiographic and magnetic resonance imaging findings of calcifying aponeurotic fibroma have been extremely rarely described in the radiology literature. Thus, we report a rare case of calcifying aponeurotic fibroma affecting the dorsal wrist in a 67-year-old man, describe radiographic and MR findings, and discuss the differential diagnosis of the tumor.

  11. Ultrasonic and radiographic evaluation of advanced aerospace materials: Ceramic composites

    Science.gov (United States)

    Generazio, Edward R.

    1990-01-01

    Two conventional nondestructive evaluation techniques were used to evaluate advanced ceramic composite materials. It was shown that neither ultrasonic C-scan nor radiographic imaging can individually provide sufficient data for an accurate nondestructive evaluation. Both ultrasonic C-scan and conventional radiographic imaging are required for preliminary evaluation of these complex systems. The material variations that were identified by these two techniques are porosity, delaminations, bond quality between laminae, fiber alignment, fiber registration, fiber parallelism, and processing density flaws. The degree of bonding between fiber and matrix cannot be determined by either of these methods. An alternative ultrasonic technique, angular power spectrum scanning (APSS) is recommended for quantification of this interfacial bond.

  12. Pulpal healing following acute dental trauma: clinical and radiographic review.

    Science.gov (United States)

    Andreasen, F M

    2001-05-01

    Successful treatment of tooth luxations, crown fractures, and root fractures is often compromised by the emergency nature of the injury. Precise radiographic and clinical evaluation is required to facilitate healing and treatment selection. While traditional treatment protocols indicate that dental injuries implying pulpal ischemia require immediate endodontic therapy to avoid healing complications, the clinical investigations discussed herein suggest that a variety of etiologies for pulp survival/pulp necrosis exist. This article discusses the long-term prognosis of pulp necrosis following traumatic dental injuries, and clinical and radiographic criteria for its diagnosis.

  13. Demonstrating the potential of yttrium-doped barium zirconate electrolyte for high-performance fuel cells

    Science.gov (United States)

    Bae, Kiho; Jang, Dong Young; Choi, Hyung Jong; Kim, Donghwan; Hong, Jongsup; Kim, Byung-Kook; Lee, Jong-Ho; Son, Ji-Won; Shim, Joon Hyung

    2017-02-01

    In reducing the high operating temperatures (>=800 °C) of solid-oxide fuel cells, use of protonic ceramics as an alternative electrolyte material is attractive due to their high conductivity and low activation energy in a low-temperature regime (fuel cells. However, poor sinterability of yttrium-doped barium zirconate discourages its fabrication as a thin-film electrolyte and integration on porous anode supports, both of which are essential to achieve high performance. Here we fabricate a protonic-ceramic fuel cell using a thin-film-deposited yttrium-doped barium zirconate electrolyte with no impeding grain boundaries owing to the columnar structure tightly integrated with nanogranular cathode and nanoporous anode supports, which to the best of our knowledge exhibits a record high-power output of up to an order of magnitude higher than those of other reported barium zirconate-based fuel cells.

  14. Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO

    CERN Document Server

    Mong, B; Walton, T; Chambers, C; Craycraft, A; Benitez-Medina, C; Hall, K; Fairbank, W; Albert, J B; Auty, D J; Barbeau, P S; Basque, V; Beck, D; Breidenbach, M; Brunner, T; Cao, G F; Cleveland, B; Coon, M; Daniels, T; Daugherty, S J; DeVoe, R; Didberidze, T; Dilling, J; Dolinski, M J; Dunford, M; Fabris, L; Farine, J; Feldmeier, W; Fierlinger, P; Fudenberg, D; Giroux, G; Gornea, R; Graham, K; Gratta, G; Heffner, M; Hughes, M; Jiang, X S; Johnson, T N; Johnston, S; Karelin, A; Kaufman, L J; Killick, R; Koffas, T; Kravitz, S; Krucken, R; Kuchenkov, A; Kumar, K S; Leonard, D S; Licciardi, C; Lin, Y H; Ling, J; MacLellan, R; Marino, M G; Moore, D; Odian, A; Ostrovskiy, I; Piepke, A; Pocar, A; Retiere, F; Rowson, P C; Rozo, M P; Schubert, A; Sinclair, D; Smith, E; Stekhanov, V; Tarka, M; Tolba, T; Twelker, K; Vuilleumier, J -L; Walton, J; Weber, M; Wen, L J; Wichoski, U; Yang, L; Yen, Y -R; Zhao, Y B

    2014-01-01

    Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of $\\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.

  15. Improved thermal stability and wettability behavior of thermoplastic polyurethane / barium metaborate composites

    Energy Technology Data Exchange (ETDEWEB)

    Baştürka, Emre; Madakbaş, Seyfullah; Kahraman, Memet Vezir, E-mail: smadakbas@marmara.edu.tr [Department of Chemistry, Marmara University, Istanbul (Turkey)

    2016-03-15

    In this paper, it was targeted to the enhance thermal stability and wettability behavior of thermoplastic polyurethane (TPU) by adding barium metaborate. TPU-Barium metaborate composites were prepared by adding various proportions of barium metaborate to TPU. The chemical structures of the composites were characterised by fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) analysis. All prepared composites have extremely high Tg and thermal stability as determined from DSC and TGA analysis. All composite materials have the Tg ranging from 15 to 35 °C. The surface morphologies of the composites were investigated by a scanning electron microscopy. Mechanical properties of the samples were characterized with stress-strain test. Hydrophobicity of the samples was determined by the contact angle measurements. The obtained results proved that thermal, hydrophobic and mechanical properties were improved. (author)

  16. Determination of barium in bottled drinking water by graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Fagioli, F.; Locatelli, C.; Lanciotti, E.; Vallone, G.; Mazzotta, D.; Mugelli, A.

    1988-11-01

    In relation to the wide environmental spread of barium and to its cardiovascular effects, barium levels were determined by graphite furnace atomic absorption spectrometry in 60 different brands of bottled water marketed in Italy. Matrix interferences were investigated in order to evaluate the use of an analytical calibration function rather than the much more time consuming addition technique. The barium content ranged from limit of detection C/sub L/ (7.0 ..mu..g/1) up to 660 ..mu..g/1, the median value being 80 ..mu..g/l, while the recovery tests varied between 90 and 110% and the precision of the method (s/sub yx/) was 2.5%.

  17. Individual-specific transgenerational marking of fish populations based on a barium dual-isotope procedure.

    Science.gov (United States)

    Huelga-Suarez, Gonzalo; Moldovan, Mariella; Garcia-Valiente, America; Garcia-Vazquez, Eva; Alonso, J Ignacio Garcia

    2012-01-01

    The present study focuses on the development and evaluation of an individual-specific transgenerational marking procedure using two enriched barium isotopes, (135)Ba and (137)Ba, mixed at a given and selectable molar ratio. The method is based on the deconvolution of the isotope patterns found in the sample into four molar contribution factors: natural xenon (Xe nat), natural barium (Ba nat), Ba135, and Ba137. The ratio of molar contributions between Ba137 and Ba135 is constant and independent of the contribution of natural barium in the sample. This procedure was tested in brown trout ( Salmo trutta ) kept in captivity. Trout were injected with three different Ba137/Ba135 isotopic signatures ca. 7 months and 7 days before spawning to compare the efficiency of the marking procedure at long and short term, respectively. The barium isotopic profiles were measured in the offspring by means of inductively coupled plasma mass spectrometry. Each of the three different isotopic signatures was unequivocally identified in the offspring in both whole eggs and larvae. For 9 month old offspring, the characteristic barium isotope signatures could also be detected in the otoliths even in the presence of a high and variable amount of barium of natural isotope abundance. In conclusion, it can be stated that the proposed dual-isotope marking is inheritable and can be detected after both long-term and short-term marking. Furthermore, the dual-isotope marking can be made individual-specific, so that it allows identification of offspring from a single individual or a group of individuals within a given fish group.

  18. Chemical composition of nanomodified composite binder with nano- and microsized barium silicate

    Directory of Open Access Journals (Sweden)

    KOROLEV Evgenij Valerjevich

    2014-08-01

    Full Text Available There are several possibilities to improve cement-based binders. In particular, many properties of cement stone can be enhanced by means of micro- and nanoscale modification. In a number of previous works we had shown that application of barium hydrosilicates leads to such improvement. The present article is devoted to the investigation of the chemical composition of the cement stone which is modified by means of addition of barium hydrosilicates. The modification was performed on different scales: micro- and nanoscale; the results of simultaneous multi-scale modification are also presented. The examination was carried out with help of different modern research techniques – FT IR spectroscopy, differential thermal analysis and X-ray phase analysis. Identification of the new phases and comparative quantitative assessment of their content are performed. It is found that the use of nano- and micro-sized barium hydrosilicates as additives leads to reduction of portlandite by 27...28%; by means of multi-scale modification it is possible to reduce the content of portlandite much more (by 83.3%. Due to addition of nano- and micro-sized barium-based modifiers both the amount of calcium hydrosilicates in reaction products is enlarged, and structure of the mentioned hydrosilicates is changed (the formation of a fine-grained structure of hydration products takes place. Micro-sized barium hydrosilicates are chemically active additives and promote the formation of an additional quantity of calcium hydrosilicates of type CSH (I. The use of nanoscale barium hydrosilicates promotes the formation of CSH (I and CSH (II calcium hydrosilicates, and also both riversidite and xonotlite. As a result of simultaneous application of nano- and micro-sized barium hydrosilicates the content of CSH (II increases. This can be confirmed by means of differential thermal and X-ray analysis. The amount of CSH (I, riversidite and various tobermorites is also increases. It is

  19. Synthesis, characterization and thermostability of barium β-diketonate with tetraethylenepentamine ligand

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The metal-organic chemical vapor deposition (MOCVD) technique is a promising process for high-temperature superconductor YBa2Cu3O7-δ(YBCO) preparation. In this technique, it is a challenge to obtain barium precursors with high volatility. In addition, the purity, evaporation characteristics and thermostability of adopted precursors in the whole process would decide the quality and reproducible results of YBCO film. In the present report, the barium precursor containing 2,2,6,6-tetramethylheptane-3,5-dionate...

  20. Study of the microstructural transformations of borate glass and barium metaborate crystals induced by femtosecond laser

    Institute of Scientific and Technical Information of China (English)

    Chen Bin; Yu Bing-Kun; Yan Xiao-Na; Qiu Jian-Rong; Jiang Xiong-Wei; Zhu Cong-Shan

    2004-01-01

    This paper describes the microstructural transformations of borate glass and barium metaborate crystals induced by femtosecond laser. Such structural transformations were verified by Raman spectroscopy. The borate glass is transformed into low temperature (LT) phase of barium metaborate (BaB2O4) crystals after being irradiated for 10 min by a femtosecond laser. In addition, after 20 min of irradiation, high temperature (HT) phase of BaB2O4 crystals is also produced. Further studies demonstrate that LT phase BaB2O4 crystals are formed in the HT phase BaB2O4 crystals after femtosecond laser irradiation for 10 s.

  1. Temperature-Dependent Raman Spectra and Microstructure of Barium Metaborate Crystals and Its Melts

    Institute of Scientific and Technical Information of China (English)

    尤静林; 蒋国昌; 侯怀宇; 吴永全; 陈辉; 徐匡迪

    2002-01-01

    We have measured the Raman spectra of β- and α-barium metaborate in crystal and liquid states from room temperature to 1873K, with a semiconductor laser as the laser source, coupled with a time-resolved detection system to eliminate the dense thermal emission background when temperature was considerably high.Temperature-dependent Raman spectra can clearly indicate that the phase transformation from β- to α-barium metaborate has been completed during 1273 - 1300 K. Variations of different kinds of microstructure units with temperature are identified and discussed.

  2. Dielectric properties of piezoelectric 3–0 composites of lithium ferrite/barium titanate

    Indian Academy of Sciences (India)

    P Sarah; S V Suryanarayana

    2003-12-01

    Piezoelectric 3–0 composite ceramics are prepared from a mixture of barium titanate and lithium ferrite phase constituents. Dielectric properties of composites are affected by a number of parameters that include electrical properties, size, shape and amount of constituent phases. The frequency dependent measurements can provide additional insight into mechanisms controlling electrical response. Frequency dependence of dielectric constant plots of lithium ferrite/barium titanate composites will be given and the relevance of trends seen in them will be discussed. Connectivity in composites developed is studied.

  3. Physical states and properties of barium titanate films in a plane electric field

    Science.gov (United States)

    Shirokov, V. B.; Kalinchuk, V. V.; Shakhovoi, R. A.; Yuzyuk, Yu. I.

    2016-07-01

    The influence of a plane electric field on the phase states of barium titanate thin films under the conditions of forced deformation has been studied. The field dependence of a complete set of material constants has been taken in the region of the c-phase, where polarization losses are absent. The material constants are calculated using equations of the piezoelectric effect derived by linearizing the nonlinear equations of state from the phenomenological; theory for barium titanate. It has been shown that there is a critical value of the field at which the electromechanical coupling coefficient reaches a maximum.

  4. Synthesis and characterization of nickel oxide doped barium strontium titanate ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, M. [Dept. of Electrical Engineering, Bengal Institute of Technology Kolkata (India); Mukherjee, S. [Dept. of Metallurgical Engineering, Jadavpur University, Kolkata (India); Maitra, S. [Govt. College of Engg. and Ceramic Technology, Kolkata (India)

    2012-01-15

    Barium strontium titanate (BST) ceramics (Ba{sub 0.6}Sr{sub 0.4})TiO{sub 3} were synthesized by solid state sintering using barium carbonate, strontium carbonate and rutile as the precursor materials. The samples were doped with nickel oxide in different proportions. Different phases present in the sintered samples were determined from X-ray diffraction investigation and the distribution of different phases in the microstructure was assessed from scanning electron microscopy study. It was observed that the dielectric properties of BST were modified significantly with nickel oxide doping. These ceramics held promise for applications in tuned circuits. (author)

  5. A reflection on the role of an emergency care Consultant Radiographer in achieving appropriate imaging conditions for nasogastric tube positioning

    Energy Technology Data Exchange (ETDEWEB)

    Jones, H.C. [Royal Liverpool University Hospital Trust, Prescot Street, Liverpool L7 8XP (United Kingdom)], E-mail: helen.jones@rlbuht.nhs.uk; Robinson, L. [University of Salford, Frederick Road, Salford M6 6UP (United Kingdom)

    2008-12-15

    The College of Radiographers state that the role of a Consultant Radiographer comprises four core functions [College of Radiographers. Developing a business case for consultant radiographers. London: College of Radiographers; 2003; Hardy M, Snaith B. How to achieve consultant practitioner status: a discussion paper. Radiography, in press. doi:10.1016/j.radi.2006.04.003 [accessed 16.08.07

  6. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2012-11-15

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  7. Localized Fisher vector representation for pathology detection in chest radiographs

    Science.gov (United States)

    Geva, Ofer; Lieberman, Sivan; Konen, Eli; Greenspan, Hayit

    2016-03-01

    In this work, we present a novel framework for automatic detection of abnormalities in chest radiographs. The representation model is based on the Fisher Vector encoding method. In the representation process, we encode each chest radiograph using a set of extracted local descriptors. These include localized texture features that address typical local texture abnormalities as well as spatial features. Using a Gaussian Mixture Model, a rich image descriptor is generated for each chest radiograph. An improved representation is obtained by selection of features that correspond to the relevant region of interest for each pathology. Categorization of the X-ray images is conducted using supervised learning and the SVM classifier. The proposed system was tested on a dataset of 636 chest radiographs taken from a real clinical environment. We measured the performance in terms of area (AUC) under the receiver operating characteristic (ROC) curve. Results show an AUC value of 0.878 for abnormal mediastinum detection, and AUC values of 0.827 and 0.817 for detection of right and left lung opacities, respectively. These results improve upon the state-of-the-art as compared with two alternative representation models.

  8. Radiographic characterization of the os penis in the cat.

    Science.gov (United States)

    Piola, Valentina; Posch, Barbara; Aghte, Petra; Caine, Abby; Herrtage, Michael E

    2011-01-01

    The os penis in the cat has not been described radiographically, as compared with the dog. However, a small linear bony radiopacity is sometimes detected in the perineal area of male cats. We hypothesized that the feline os penis might be visible on survey radiographs of the pelvis, and we aimed to investigate the frequency of its visualization using analog and computed radiography (CR) system. One hundred radiographs of the pelvis of 99 male cats were reviewed retrospectively (50 were obtained with a CR system and 50 with an analog system). Age, breed, neutering status, and reason for presentation were recorded, as well as the visualization of the os penis. An os penis was detected in 19/50 (38%) cats with CR and in eight of 50 (16%) cats with analog radiography; this difference was statistically significant. With CR, the median age of cats with a visible os penis was significantly higher than in cats where the os penis was not seen. In one cat with a visible os penis examined with CR and analog radiography, the os penis was only visible on CR images. The penile tissues were examined histopathologically in one cat and well-differentiated bone was found but there were no pathologic findings detected in surrounding tissues. Thus, the os penis can be detected on radiographs of cats and this should not be mistaken for a pathologic finding such as urolithiasis or dystrophic mineralization.

  9. Radiographic Sensitivity of Flaw Detection in Solid Rocket Propellants

    Directory of Open Access Journals (Sweden)

    G.G Puranik

    1977-10-01

    Full Text Available The sensitivity of flaw detection with x-ray radiographic methods is investigated here qualitatively in case of cast double base and cast composite propellants and for air pockets it is found to be 1.5 and 0.9 percent of the web respectively. General guidelines for the inspection of sustainer charges have also been laid down.

  10. Prediction of gestational age of infants from the abdominal radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, M.R.; Edwards, D.K.

    1980-07-01

    Measurements of lumbar spine elements on abdominal radiographs of 183 white infants were compared with the estimated gestational ages of these infants as determined by physical examination. Using the technique of multiple regression, an equation was derived to predict infant age from the measurements of the spine.

  11. Herpes simplex virus 1 pneumonia: conventional chest radiograph pattern

    Energy Technology Data Exchange (ETDEWEB)

    Umans, U.; Golding, R.P.; Duraku, S.; Manoliu, R.A. [Dept. of Radiology, Academic Hospital ' ' Vrije Universiteit' ' , Amsterdam (Netherlands)

    2001-06-01

    The aim of this study was to describe the findings on plain chest radiographs in patients with herpes simplex virus pneumonia (HSVP). The study was based on 17 patients who at a retrospective search have been found to have a monoinfection with herpes simplex virus. The diagnosis was established by isolation of the virus from material obtained during fiberoptic bronchoscopy (FOB) which also included broncho-alveolar lavage and tissue sampling. Fourteen patients had a chest radiograph performed within 24 h of the date of the FOB. Two radiographs showed no abnormalities of the lung parenchyma. The radiographs of the other 12 patients showed lung opacification, predominantly lobar or more extensive and always bilateral. Most patients presented with a mixed airspace and interstitial pattern of opacities, but 11 of 14 showed at least an airspace consolidation. Lobar, segmental, or subsegmental atelectasis was present in 7 patients, and unilateral or bilateral pleural effusion in 8 patients, but only in 1 patient was it a large amount. In contradiction to the literature which reports a high correlation between HSVP and acute respiratory distress syndrome (ARDS), 11 of 14 patients did not meet the pathophysiological criteria for ARDS. The radiologist may suggest the diagnosis of HSVP when bilateral airspace consolidation or mixed opacities appear in a susceptible group of patients who are not thought to have ARDS or pulmonary edema. The definite diagnosis of HSV pneumonia can be established only on the basis of culture of material obtained by broncho-alveolar lavage. (orig.)

  12. Thalassemia: essential radiographic and clinical features of interest to dentistry

    Directory of Open Access Journals (Sweden)

    Luiz Roberto Coutinho Manhães Junior

    2008-01-01

    Full Text Available Thalassemia is a type of hereditary anemia that predominantly affects individuals born in or descendents of countries bathed by the Mediterranean Sea, such as Italy and Greece. Also known as Cooley’s anemia and Mediterranean anemia, the disease causes alterations in hemoglobin formation and malformations of the cranium, long bones, maxilla and mandible. It presents two distinct clinical conditions: one severe, called “major” thalassemia, and the other mild, denominated “minor” thassalemia. Hematologic exam diagnoses the two forms of the disease. Its clinical and radiographic manifestations include hepatosplenomegalia, lymphadenopathy, augmented mandible, increase in medullary spaces, thick bone trabeculae and in lower quantity, resembling a “spider web”, displacement of the mandibular canal, with loss of detail of its superior and inferior corticals and a radiographic aspect of “hair standing on end” at the surface of the cranium. Some of these manifestations are so characteristic and capable of being observed in radiographs that they form part of the dentist’s routine. This case report discusses the alterations observed in the panoramic radiograph of a patient with thalassemia diagnosed by means of hematologic exam.

  13. Radiographic Study of Bony Changes of the Mandibular Condyle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung A; Koh, Kwang Joon [Dept. of Oral and Maxillofacial Radiology and Institute of Oral Bio Science, School of Dentistry, Chonbuk National University, Chonju (Korea, Republic of)

    2000-03-15

    The purpose of this study is to compare radiographic techniques for the diagnostic accuracy in the detection of osteophytes of the mandibular condyle. A series of bone chips were placed at four locations on the condylar head of a dried human skull. Eight radiographic techniques such as panoramic, transcranial, infracranial, transorbital, reverse-Towne's, submentovertex, multidirectional tomographic and computed tomographic techniques were compared. Three oral radiologists were asked to rate the lesions by four stage score. The statistical analysis was performed by ANOVA test. For the detection of lateral osteophyte, transcranial, infracranial, transorbital and reverse-Towne's views showed superiority. Also, transcranial and infracranial views showed superiority for medial osteophyte. While for the detection of superior and anterior osteophyte, panoramic, transcranial, infracranial, transorbital views showed superiority. Lateral tomograph showed superiority for the detection of superior and anterior osteophyte, but it showed inferiority for lateral and medial osteophte. And antero-posterior tomograph showed superiority for the detection of all osteophytes. Axial computed tomograph showed superiority for the detection of all osteophytes, and coronal computed tomograph showed superiority for lateral, medial and superior osteophytes. While reconstructed sagittal computed tomograph showed relatively superiority for the detection of anterior and superior osteophytes. The conventional radiographs can be used for the detection of bony changes of the mandibular condyle, and tomograph or computed tomograph can be used additionally when it is difficult to detect bony changes on conventional radiographs.

  14. Information content of low-dose radiographs: Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R.A.

    1997-10-01

    The previous paper described the concept of using the net number of information bits transmitted in a radiographic image as a measure of the contrast parameter of image quality. The concept is particularly useful when the image contrast is limited by the statistics of the photon fluence incident on the detector (low doses). The Wolfram Research Mathematica program (described in Ref. 1) that was used to simulate a noisy image of an object with two thicknesses and to calculate the resulting IC (information content). The only noise source in the simulation was fluctuations in the photon fluence incident on the detector. The results from the simulation were compared to data obtained from actual radiographs of a copper step wedge radiographed with 10 and 50 pulses from a 150-p, V x-ray machine. Good agreement between the simulation and experiment was obtained when the photon fluence was considered a free, adjustable parameter. This report extends the simulation described in Ref. 1 and shows how IC varies as the following radiographic parameters change: object thickness; object Z number; x-ray energy; and incident x-ray fluence.

  15. Utilization of Radiographs for a State Dental Hygiene Board Examination.

    Science.gov (United States)

    Potter, Brad G.; And Others

    1993-01-01

    A study documented the number of x-rays acquired during screening and subsequent treatment of patients for a state dental hygiene licensing examination for 109 candidates. Results indicate that patient exposure guidelines attempt to minimize radiographic exposure but that some exposures should be reevaluated for need and effect on patients. (MSE)

  16. Advanced Neutron Radiographic Equipment within the US Army

    Science.gov (United States)

    2014-01-29

    The first of the two new neutron generators developed for ARDEC was built and delivered by Phoenix Nuclear Labs ( PNL ) located in Madison, WI...PRELIMINARY NEUTRON RADIOGRAPHS AND RESULTS During the hardware and software testing of the PNL neutron generator several test shots were

  17. Radiographic appearance of commonly used cements in implant dentistry.

    Science.gov (United States)

    Pette, Gregory A; Ganeles, Jeffrey; Norkin, Frederic J

    2013-01-01

    Cement-retained restorations allow for a conventional fixed partial denture approach to restoring dental implants. However, inadequate removal of excess cement at the time of cementation may introduce a severe complication: cement-induced peri-implantitis. Radiopaque cements are more easily detected on radiographs and should improve the recognition of extravasated cement at the time of insertion. The purpose of this study was to evaluate the radiopacity of commercially available cements in vitro. Eighteen different cements commonly used for luting restorations to implants were tested at both 0.5- and 1.0-mm thicknesses. The cements examined were zinc oxide eugenol, zinc oxide, zinc polycarboxylate, zinc phosphate, resin-reinforced glass ionomer, urethane resin, resin, and composite resin. Two samples of each cement thickness underwent standardized radiography next to an aluminum step wedge as a reference. The mean grayscale value of each of the nine 1-mm steps in the step wedge were used as reference values and compared to each of the cement samples. Temp Bond Clear (resin), IMProv (urethane resin), Premier Implant Cement (resin), and Temrex NE (resin) were not radiographically detectable at either sample thickness. Cements containing zinc were the most detectable upon radiographic analysis. There are significant differences in the radiopacity of many commonly used cements. Since cementinduced peri-implantitis can lead to late implant failure, cements that can be visualized radiographically may reduce the incidence of this problem.

  18. Evaluation of angiography performed by radiographers and nurses

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A

    2002-04-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  19. Acute neuropathic joint in diabetic foot: Plain radiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Dae Young; Kang, Heung Sik; Sim, Jung Suk; Yoon, Yong Kyu; Kim, Chu Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-05-15

    To determine the plain film findings of acute neuropathic joint in diabetic foot. Acute neuropathic joint in diabetic foot was considered when fragmentation of the articular ends of bone and subluxation of the affected joint developed within eight weeks after clinical onset of diabetic gangrene. Eight toes of six diabetics were satisfactory to our criteria. We analyzed plain radiographic findings of the affected joint and soft tissue, interval changes in followed-up radiographs, and deformities after healing. The time interval between clinical onset of gangrene and bone destruction ranges from 2 weeks to 4 weeks(mean 2.6 weeks). Plane radiographs showed fragmentation of the articular ends, subluxation, and soft tissue swelling of the metatarsophalangeal joint or interphalangeal joint. The significant feature of these patients was rapid progression of the lesions. Clinically, all patients had diabetic gangrene in affected toes, however, there was no evidence of osteomyelitis in our series. Amputation was done in 2 cases, and lesions in 3 of the remaining 4 cases were repaired spontaneously with regression of gangrene, leaving radiological residua such as pointed-end, tapered-end, and ball and socket deformity. Rapid disorganisation of the joint with associated evidence of soft tissue gangrene in plain radiograph is believed to be valuable for the diagnosis of diabetic osteoarthropathy.

  20. 10 CFR Appendix A to Part 34 - Radiographer Certification

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiographer Certification A Appendix A to Part 34 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR... of industrial radiography; 2. Make its membership available to the general public nationwide that...

  1. Basal cell naevus syndrome - radiographic findings in the skull

    Energy Technology Data Exchange (ETDEWEB)

    Stoll, P.; Dueker, J.; Weingart, D.

    1986-09-01

    Besides uni- and multiocular jaw cysts the Gorlin Goltz syndrome shows other characteristic radiographic findings which help to ensure diagnosis. These are particularly calcification of the falx cerebri and a so called ''bridging'' between processus clinoideus anterior and posterior of the sella turcica. The importance of early diagnosis is stressed.

  2. Radiographic display of carious lesions and cavitation in approximal surfaces

    DEFF Research Database (Denmark)

    Wenzel, Ann

    2014-01-01

    . In addition, there are few longitudinal observational studies on the behaviour of dentinal carious lesions, particularly in adults. Cone beam computed tomography. Cone beam CT is an advanced 3-dimensional radiographic modality, which seems much more accurate than intra-oral modalities for displaying...

  3. Digital radiographic technology; non-destructive testing of tubine blades

    NARCIS (Netherlands)

    Penumadu, P.S.

    2014-01-01

    Inspection of turbine blades has always been a big challenge. Any irregularities in the blade have a huge impact on the gas turbine, so these blades have to be manufactured and inspected in the most sophisticated way possible. The evolution of digital radiographic technology took a leap forward to s

  4. Assessment of radiation protection practices among radiographers in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Cletus Uche Eze

    2013-01-01

    Full Text Available Background: Use of ionising radiation in diagnostic radiography could lead to hazards such as somatic and genetic damages. Compliance to safe work and radiation protection practices could mitigate such risks. The aim of the study was to assess the knowledge and radiation protection practices among radiographers in Lagos, Nigeria. Materials and Methods: The study was a prospective cross sectional survey. Convenience sampling technique was used to select four x-ray diagnostic centres in four tertiary hospitals in Lagos metropolis. Data were analysed with Epi- info software, version 3.5.1. Results: Average score on assessment of knowledge was 73%. Most modern radiation protection instruments were lacking in all the centres studied. Application of shielding devices such as gonad shield for protection was neglected mostly in government hospitals. Most x-ray machines were quite old and evidence of quality assurance tests performed on such machines were lacking. Conclusion: Radiographers within Lagos metropolis showed an excellent knowledge of radiation protection within the study period. Adherence to radiation protection practices among radiographers in Lagos metropolis during the period studied was, however, poor. Radiographers in Lagos, Nigeria should embrace current trends in radiation protection and make more concerted efforts to apply their knowledge in protecting themselves and patients from harmful effects of ionising radiation.

  5. Radiographic femoral varus measurement is affected unpredictably by femoral rotation

    DEFF Research Database (Denmark)

    Miles, James Edward

    Radiographic measurements of femoral varus are used to determine if intervention to correct femoral deformity is required, and to calculate the required correction. The varus angle is defined as the angle between the proximal femoral long axis (PFLA) and an axis tangential to the distal femoral c...

  6. OPTICAL QUANTITATION AND RADIOGRAPHIC DIAGNOSIS OF INCIPIENT APPROXIMAL CARIES LESIONS

    NARCIS (Netherlands)

    VERDONSCHOT, EH; VANDERIJKE, JW; BROUWER, W; TENBOSCH, JJ; TRUIN, GJ

    1991-01-01

    The objectives of this study were to test the applicability of photocell measurements in approximal caries diagnosis and to evaluate the use of radiographs as validating criterion. Forty extracted premolars were selected, and the progression of the approximal lesions was graded clinically and radiog

  7. Radiographic features of tuberculous osteitis in greater trochanter and lschium

    Energy Technology Data Exchange (ETDEWEB)

    Hahm, So Hee; Lee, Ye Ri [Hanil Hospital Affiliated to KEPCO, Seoul (Korea, Republic of); Kim, Dong Jin; Sung, Ki Jun [Yonsei Univ. Wonju College of Medicine, Wonju (Korea, Republic of); Lim, Jong Nam [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate, if possible, the radiographic features of tuberculous osteitis in the greater trochanter and ischium, and to determine the cause of the lesions. We reterospectively reviewed the plain radiographic findings of 14 ptients with histologically proven tuberculous osteitis involving the greater trochanter and ischium. In each case, the following were analyzed:morphology of bone destruction, including cortical erosion;periosteal reaction;presence or abscence of calcific shadows in adjacent soft tissue. On the basis of an analysis of radiographic features and correlation of the anatomy with adjacent structures we attempted to determine causes. Of the 14 cases evaluated, 12 showed varrious degrees of extrinsic erosion on the outer cortical bone of the greater trochanter and ischium ; in two cases, bone destruction was so severe that the radiographic features of advanced perforated osteomyelitis were simulated. In addition to findings of bone destruction, in these twelve cases, the presence of sequestrum or calcific shadows was seen in adjacent soft tissue. Tuberculous osteitis in the greater trochanter and ischium showed the characteristic findings of chronic extrinsic erosion. On the basis of these findings we can suggest that these lesions result from an extrinsic pathophysiologic cause such as adjacent bursitis.

  8. Systematic assessment of constipation on plain abdominal radiographs in children

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, Maurice van den; Graafmans, Doortje [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Nievelstein, Rutger; Beek, Erik [Wilhelmina Children' s Hospital, Department of Paediatric Radiology, Utrecht (Netherlands)

    2006-03-15

    Constipation in childhood is common and its clinical assessment is often difficult. Plain abdominal radiography is simple and used to quantify constipation. Three scoring systems, those of Barr et al., Leech et al. and Blethyn et al., have been developed to quantify fecal loading on the abdominal radiograph. In order to determine which method is the most useful in clinical practice, we assessed the reproducibility of the three scoring systems. Plain abdominal radiographs from 40 clinically constipated children were retrospectively reviewed by two paediatric radiologists on two separate occasions. The radiographs were scored according to three different systems developed by Barr et al., Leech et al., Blethyn et al. Intraobserver variability and interobserver reproducibility were determined for each system. Kappa coefficients were calculated as indicators of inter- and intraobserver agreement for categorical outcome variables. The Leech score showed the highest reproducibility: the intraobserver agreement was high for both observers ({kappa} values of 0.88 and 1.00, respectively, P<0.05). Furthermore, the interobserver agreement was also high: {kappa} 0.91 in the first round and 0.84 in the second. The Leech score proved to be a highly reproducible tool for assessment of childhood constipation and is of value in clinical practice for systematic assessment of constipation on plain abdominal radiographs in children. (orig.)

  9. Digital scoring of haemophilic arthropathy using radiographs is feasible

    NARCIS (Netherlands)

    Jansen, N. W. D.; Vincken, K. L.; Marijnissen, A. C. A.; Lundin, B.; Heijnen, L.; Roosendaal, G.; Pettersson, H.; Lafeber, F. P. J. G.

    2008-01-01

    Radiographs are important tools to evaluate structural changes in many Joint diseases. In the case of haemophilic arthropathy (HA), the Pettersson score is widely used. The rising of digital radiography enables evaluation of these changes in a more quantitative and detailed manner, potentially impro

  10. Regeneration of barium carbonate from barium sulphide in a pilot-scale bubbling column reactor and utilization for acid mine drainage.

    Science.gov (United States)

    Mulopo, J; Zvimba, J N; Swanepoel, H; Bologo, L T; Maree, J

    2012-01-01

    Batch regeneration of barium carbonate (BaCO(3)) from barium sulphide (BaS) slurries by passing CO(2) gas into a pilot-scale bubbling column reactor under ambient conditions was used to assess the technical feasibility of BaCO(3) recovery in the Alkali Barium Calcium (ABC) desalination process and its use for sulphate removal from high sulphate Acid Mine Drainage (AMD). The effect of key process parameters, such as BaS slurry concentration and CO(2) flow rate on the carbonation, as well as the extent of sulphate removal from AMD using the recovered BaCO(3) were investigated. It was observed that the carbonation reaction rate for BaCO(3) regeneration in a bubbling column reactor significantly increased with increase in carbon dioxide (CO(2)) flow rate whereas the BaS slurry content within the range 5-10% slurry content did not significantly affect the carbonation rate. The CO(2) flow rate also had an impact on the BaCO(3) morphology. The BaCO(3) recovered from the pilot-scale bubbling column reactor demonstrated effective sulphate removal ability during AMD treatment compared with commercial BaCO(3).

  11. Radiographic diagnosis of dental restoration misfit: a systematic review.

    Science.gov (United States)

    Liedke, G S; Spin-Neto, R; da Silveira, H E D; Wenzel, A

    2014-12-01

    The objective of this study was to perform a systematic review on the use of radiographic methods for the diagnosis of misfit in dental prostheses and restorations. The MEDLINE bibliographic database was searched from 1950 to February 2014 for reports on the radiographic diagnosis of misfits. The search strategy was limited to English-language publications using the following combined MeSH terms in the search strategy: (Dental Restoration OR Dental Prosthesis OR Crown OR Inlays OR Dental Abutments) and (Dental Leakage OR Prosthesis Fitting OR Dental Marginal Adaptation OR Surface Properties) and (Radiography, Dental OR Radiography, Dental, Digital OR Cone-Beam Computed Tomography). Twenty-eight publications were identified and read in full text, and 14 studies fulfilled criteria for inclusion. Information regarding the use of radiographic methods for the diagnosis of misfits in dental prosthesis and restorations, and in which the methodology/results comprised information regarding how the sample was collected/prepared, the method, imaging protocol, presence of a reference test and the outcomes were evaluated. QUADAS criteria was used to rate the studies in high, moderate or low quality. The evidence supporting the use of radiographic methods for the diagnosis of misfits in dental prosthesis and restorations is limited to low-/moderate-quality studies. The well-established intra-oral orthogonal projection is still under investigation and considered the most appropriate method, both when evaluating the relation between dental restoration to tooth and abutment to implant. Studies using digital radiographs have not evaluated the effect of image post-processing, and tomography has not been evaluated.

  12. Radiographic liver size in Pekingese dogs versus other dog breeds.

    Science.gov (United States)

    Choi, Jihye; Keh, Seoyeon; Kim, Hyunwook; Kim, Junyoung; Yoon, Junghee

    2013-01-01

    Differential diagnoses for canine liver disease are commonly based on radiographic estimates of liver size, however little has been published on breed variations. Aims of this study were to describe normal radiographic liver size in Pekingese dogs and to compare normal measurements for this breed with other dog breeds and Pekingese dogs with liver disease. Liver measurements were compared for clinically normal Pekingese (n = 61), normal non-Pekingese brachycephalic (n = 45), normal nonbrachycephalic (n = 71), and Pekingese breed dogs with liver disease (n = 22). For each dog, body weight, liver length, T11 vertebral length, thoracic depth, and thoracic width were measured on right lateral and ventrodorsal abdominal radiographs. Liver volume was calculated using a formula and ratios of liver length/T11 vertebral length and liver volume/body weight ratio were determined. Normal Pekingese dogs had a significantly smaller liver volume/body weight ratio (16.73 ± 5.67, P dogs (19.54 ± 5.03) and normal nonbrachycephalic breed dogs (18.72 ± 6.52). The liver length/T11 vertebral length ratio in normal Pekingese (4.64 ± 0.65) was significantly smaller than normal non-Pekingese brachycephalic breed dogs (5.16 ± 0.74) and normal nonbrachycephalic breed dogs (5.40 ± 0.74). Ratios of liver volume/body weight and liver length/T11 vertebral length in normal Pekingese were significantly different from Pekingese with liver diseases (P dogs have a smaller normal radiographic liver size than other breeds. We recommend using 4.64× the length of the T11 vertebra as a radiographic criterion for normal liver length in Pekingese dogs.

  13. Femoropatellar radiographic alterations in cases of anterior cruciate ligament failure

    Directory of Open Access Journals (Sweden)

    Diego Protásio de Vasconcelos

    2015-02-01

    Full Text Available OBJECTIVE: To make a comparative analysis on three femoropatellar radiographic parameters, between knees with chronic failure of the anterior cruciate ligament (ACL and normal knees.METHODS: Thirty volunteer patients with a diagnosis of unilateral isolated chronic ACL injury for more than one year and a normal contralateral knee were selected. Digital radiographs were produced for all the patients, on both knees in absolute lateral view at 30° of flexion, with and without load-bearing on one leg, and in axial view of the patella at 30°. The Caton-Deschamps patellar height index, Merchant patellar congruence angle and Laurin lateral patellar tilt angle were measured on the radiographs obtained from the normal knees and knees with ACL injuries, and comparative analysis was performed between these two groups.RESULTS: The patellar height was statistically significantly lower (p< 0.001 in the knees with ACL failure than in the normal knees, both on radiographs without loading and on those with single-foot loading. The Merchant patellar congruence angle was significantly smaller (p < 0.001 in the normal knees and the lateral patellar tilt angle was smaller (p < 0.001 in the knees with ACL failure.CONCLUSION: Chronic ACL failure gave rise to a statistically significant change in the femoropatellar radiographic values studied (p < 0.001. Knees with injuries to this ligament presented lower patellar height values, greater tilt and lateral displacement of the patella, in relation to the femoral trochlea, in comparison with the normal contralateral knees.

  14. Radiographic findings in restrained hip joints associated with ACL rupture.

    Science.gov (United States)

    Ellera Gomes, João L; Palma, Humberto Moreira; Becker, Ricardo

    2010-11-01

    Although decreased hip range of motion has been detected in many soccer players with noncontact anterior cruciate ligament (ACL), it is not clear whether it is associated with bone spurs, capsular soft tissue stiffness or both. Our aim was to investigate abnormal radiographic findings in soccer players with limited hip range of motion and noncontact ACL injury. Fifty consecutive male soccer players with restricted hip range of motion and noncontact ACL injury were subjected to radiographic examination to identify bone changes that could be associated with decreased hip range of motion. Of 50 patients, 56% revealed abnormal radiographic findings: pericapsular calcifications or acetabular rim osteophytes (24%), femoral neck deformity (10%), femoral neck and acetabular rim disorders (18%), neck groove caused by impingement (4%). Radiographic evaluation of those individuals showed a high number of bone abnormalities around the hip joint. This was considered to be an important finding to guide a decision-making process between three different approaches: changing the type of sports practiced, undergoing a more restrictive surgery (such as a double-bundle intra-articular reconstruction or an intra plus extra technique) or the onset of a hip-stretching program in addition to the conventional ACL rehabilitation protocol. In this last option, ACL-operated patients without radiographic hip abnormalities may have better outcomes for their decreased hip range of motion when submitted to a stretching program targeting the prevention of rotational overload on the reconstructed intra-articular grafts. The decision-making process concerning soccer players with ACL ruptures should take into consideration the amount of motion-limiting abnormalities around the hip joint.

  15. Comparison of the Diagnostic Performance of CT Colonography Interpreted by Radiologists and Radiographers

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl; Lefere, Philippe

    2013-01-01

    Objective To compare computed tomographic colonography (CTC) performance of 4 trained radiographers with the CTC performance of 2 experienced radiologists. Methods Four radiographers and two radiologists interpreted 87 cases with 40 polyps ≥6 mm. Sensitivity, specificity-, and positive predictive...

  16. A surface-chemistry study of barium ferrite nanoplates with DBSa-modified surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lisjak, Darja, E-mail: darja.lisjak@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Ovtar, Simona; Kovač, Janez [Jožef Stefan Institute, Ljubljana (Slovenia); Gregoratti, Luca; Aleman, Belen; Amati, Matteo [Elettra – Sincrotrone Trieste S.C.p.A. di interesse nazionale, Trieste (Italy); Fanetti, Mattia [University of Nova Gorica, Nova Gorica (Slovenia); Istituto Officina dei Materiali CNR, Area Science Park, Trieste (Italy); Makovec, Darko [Jožef Stefan Institute, Ljubljana (Slovenia)

    2014-06-01

    Barium ferrite (BaFe{sub 12}O{sub 19}) is a ferrimagnetic oxide with a high magnetocrystalline anisotropy that can be exploited in magnetically aligned ceramics or films for self-biased magnetic applications. Magnetic alignment of the films can be achieved by the directed assembly of barium ferrite nanoplates. In this investigation the nanoplates were synthesized hydrothermally and suspended in 1-butanol using dodecylbenzene sulphonic acid (DBSa) as a surfactant. They were then deposited in an electric or magnetic field on flat substrates and exhibited a significant preferential alignment in the plane of the substrate, allowing a differentiation between the analysis of their basal and side planes using scanning photoelectron microscopy with a lateral resolution down to 100 nm. The surface chemistry of the nanoplates was additionally studied with X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry. For a comparison, bare barium ferrite nanoplates were also analyzed after decomposing the DBSa at 460 °C. The deviation of the surface chemistry from the stoichiometric composition was observed and the adsorption of the DBSa molecules on the nanoplates was confirmed with all three methods. Different types of bonding (physi- or chemisorption) were possible and considered with respect to the assembly of the barium ferrite nanoplates into anisotropic magnetic films.

  17. X-Ray Fluorescence Analysis for Barium, Zinc, Calcium and Phosphorus in Oil Additives.

    Science.gov (United States)

    1983-08-01

    HOAlD-I’ 908 XRAY FLUORESCENCE ANALYSIS FOR BARIUM ZINC CALCIUM AND i/i PHOSPHORUS IN OIL HDDITIVES(U MATERIALS RESEARCH LABS ASCOT VALE (AUSTRALIA...film technique was used by McGinness, Scott and Mortensen [101 for the quantitative x-ray emission analysis of paints . The paint films, "one-half mil

  18. Inconceivable Hypokalemia: A Case Report of Acute Severe Barium Chloride Poisoning

    Directory of Open Access Journals (Sweden)

    Haibo Tao

    2016-01-01

    Full Text Available Barium is a heavy divalent alkaline earth metal that has been known as a muscle poison. Barium can cause human toxicity, which may lead to significant hypokalemia and have serious consequences. This paper reports a case of unprecedented barium intoxication in which the patient, who suffered from depression, swallowed at least 3.0 g barium chloride to commit suicide. On admission, the patient presented with nausea, vomiting, stomach burning feeling, dizziness, and weakness. Emergency biochemical testing showed that the patient was suffering from severe hypokalemia (K+ 1.7 mmol/L. His electrocardiogram (ECG prompted atrioventricular blocking, ventricular tachycardia, prolongation of PR interval, ST segment depression with U waves, and T wave inversion. Intravenous potassium supplements were given immediately to correct hypokalemia and regular monitoring of vital signs and fluid balance was arranged. After all-out rescue of our hospital personnel, the condition of the patient is currently stable and he is gradually recovering. This case exemplifies the weaknesses of the management of toxic substances and the lack of mental health education for young people. We hope to get more attention for the supervision of toxic substances and the healthy development of young people.

  19. Demonstrating the potential of yttrium-doped barium zirconate electrolyte for high-performance fuel cells.

    Science.gov (United States)

    Bae, Kiho; Jang, Dong Young; Choi, Hyung Jong; Kim, Donghwan; Hong, Jongsup; Kim, Byung-Kook; Lee, Jong-Ho; Son, Ji-Won; Shim, Joon Hyung

    2017-02-23

    In reducing the high operating temperatures (≥800 °C) of solid-oxide fuel cells, use of protonic ceramics as an alternative electrolyte material is attractive due to their high conductivity and low activation energy in a low-temperature regime (≤600 °C). Among many protonic ceramics, yttrium-doped barium zirconate has attracted attention due to its excellent chemical stability, which is the main issue in protonic-ceramic fuel cells. However, poor sinterability of yttrium-doped barium zirconate discourages its fabrication as a thin-film electrolyte and integration on porous anode supports, both of which are essential to achieve high performance. Here we fabricate a protonic-ceramic fuel cell using a thin-film-deposited yttrium-doped barium zirconate electrolyte with no impeding grain boundaries owing to the columnar structure tightly integrated with nanogranular cathode and nanoporous anode supports, which to the best of our knowledge exhibits a record high-power output of up to an order of magnitude higher than those of other reported barium zirconate-based fuel cells.

  20. Settling barium fluxes in the Arabian Sea: Critical evaluation of relationship with export production

    Digital Repository Service at National Institute of Oceanography (India)

    Nair, T.M.B.; Ittekkot, V.; Shankar, R.; Guptha, M.V.S.

    discrepancy is documented between the export flux calculated from the barium-based algorithm and from C sub(org) fluxes at different depths. However, approx. 35% increase in Ba fluxes and a concomitant increase in Ba/C sub(org) ratios are documented between...

  1. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    CERN Document Server

    Anderson, NG; Firsching, M; de Ruiter, N; Schleich, N; Butzer, J S; Cook, N J; Grasset, R; Campbell, M; Scott, N J A; Anderson, N G

    2010-01-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 A mu A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct f...

  2. Study of structural, ferromagnetic and ferroelectric properties of nanostructured barium doped Bismuth Ferrite

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhuri, A., E-mail: arkac123@gmail.com [Department of Applied Science, Haldia Institute of Technology, Dist.- Purba Medinipur, Haldia- 721657, West Bengal (India); Department of Condensed Matter Physics and Material Science, S.N. Bose National Center for Basic Sciences, Block JD, Salt Lake, Kolkata 700098 (India); Mandal, K. [Department of Applied Science, Haldia Institute of Technology, Dist.- Purba Medinipur, Haldia- 721657, West Bengal (India); Department of Condensed Matter Physics and Material Science, S.N. Bose National Center for Basic Sciences, Block JD, Salt Lake, Kolkata 700098 (India)

    2014-03-15

    Nanostructured multiferroic Bi{sub (1−x)}Ba{sub x}FeO{sub 3}x=0.0, 0.1, 0.2 were prepared by hydrothermal technique. All samples belonged to the rhombohedrally distorted perovskite structure. The morphology of the particles changed with the doping of barium. Effect of barium doping on the dielectric constant was studied over a wide frequency range of 1000 Hz–1 MHz. The activation energy due to relaxation and due to conduction was measured from the Cole Cole plot and the AC conductivity versus frequency plot respectively. The activation energy estimated from both the studies was close to each other. The activation energy also enhanced with the increase in the barium content. The magnetization at the highest available field (∼1.6 T) increased from 0.05 emu/g for the sample with x=0.0–12 emu/g for the sample with x=0.2. The magnetic measurements show a significant increase in magnetization around 400 °C. Remnant polarization for x=0.0 was negligible and it increased to 0.06 µC/cm{sup 2} for x=0.2. - Highlights: • Bismuth Ferrite nanostructures were synthesized by the hydrothermal technique. • Barium was doped in Bismuth site. • Morphology changed with doping. • Ferromagnetic, Ferroelectric and Dielectric properties enhanced with doping. • An unreported magnetic transition due to spin canting was observed near 550 °C.

  3. Electromechanical Response of Polycrystalline Barium Titanate Resolved at the Grain Scale

    DEFF Research Database (Denmark)

    Majkut, Marta; Daniels, John E.; Wright, Jonathan P.

    2017-01-01

    critical for understanding bulk polycrystalline ferroic behavior. Here, three-dimensional X-ray diffraction is used to reconstruct a 3D grain map (grain orientations and neighborhoods) of a polycrystalline barium titanate sample and track the grain-scale non-180° ferroelectric domain switching strains...

  4. Diffuse X-ray scattering and far infrared absorption of barium and lead β" aluminas

    DEFF Research Database (Denmark)

    Hayes, W.; Kjær, Kristian; Pratt, F. L.;

    1985-01-01

    The authors have carried out high-momentum-resolution studies in diffuse X-ray scattering of barium and lead B" aluminas in the temperature range 20-700 degrees C. They have also measured the vibrational spectra of these compounds between 2K and 300K in the energy range 10-100 cm-1. The results a...

  5. A clinico-radiographic analysis of sagittal condylar guidance determined by protrusive interocclusal registration and panoramic radiographic images in humans

    Directory of Open Access Journals (Sweden)

    D Krishna Prasad

    2012-01-01

    Full Text Available Purpose: To evaluate the correlation between sagittal condylar guidance obtained by protrusive interocclusal records and panoramic radiograph tracing methods in human dentulous subjects. Materials and Methods: The sagittal condylar guidance was determined in 75 dentulous subjects by protrusive interocclusal records using Aluwax through a face bow transfer (HANAU™ Spring Bow, Whip Mix Corporation, USA to a semi-adjustable articulator (HANAU™ Wide-Vue Articulator, Whip Mix Corporation, USA. In the same subjects, the sagittal outline of the articular eminence and glenoid fossa was traced in panoramic radiographs. The sagittal condylar path inclination was constructed by joining the heights of curvature in the glenoid fossa and the corresponding articular eminence. This was then related to the constructed Frankfurt′s horizontal plane to determine the radiographic angle of sagittal condylar guidance. Results: A strong positive correlation existed between right and left condylar guidance by the protrusive interocclusal method (P 0.000 and similarly by the radiographic method (P 0.013. The mean difference between the condylar guidance obtained using both methods were 1.97° for the right side and 3.18° for the left side. This difference between the values by the two methods was found to be highly significant for the right (P 0.003 and left side (P 0.000, respectively. The sagittal condylar guidance obtained from both methods showed a significant positive correlation on right (P 0.000 and left side (P 0.015, respectively. Conclusion: Panoramic radiographic tracings of the sagittal condylar path guidance may be made relative to the Frankfurt′s horizontal reference plane and the resulting condylar guidance angles used to set the condylar guide settings of semi-adjustable articulators.

  6. Possible discovery of the r-process characteristics in the abundances of metal-rich barium stars

    CERN Document Server

    Cui, W Y; Shi, J R; Zhao, G; Wang, W J; Niu, P

    2014-01-01

    We study the abundance distributions of a sample of metal-rich barium stars provided by Pereira et al. (2011) to investigate the s- and r-process nucleosynthesis in the metal-rich environment. We compared the theoretical results predicted by a parametric model with the observed abundances of the metal-rich barium stars. We found that six barium stars have a significant r-process characteristic, and we divided the barium stars into two groups: the r-rich barium stars ($C_r>5.0$, [La/Nd]\\,$<0$) and normal barium stars. The behavior of the r-rich barium stars seems more like that of the metal-poor r-rich and CEMP-r/s stars. We suggest that the most possible formation mechanism for these stars is the s-process pollution, although their abundance patterns can be fitted very well when the pre-enrichment hypothesis is included. The fact that we can not explain them well using the s-process nucleosynthesis alone may be due to our incomplete knowledge on the production of Nd, Eu, and other relevant elements by the ...

  7. Measuring x-ray spectra of flash radiographic sources [PowerPoint

    Energy Technology Data Exchange (ETDEWEB)

    Gehring, Amanda Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Espy, Michelle A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Haines, Todd Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mendez, Jacob [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Moir, David C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sedillo, Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Shurter, Roger P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Volegov, Petr Lvovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Webb, Timothy J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-11-02

    The x-ray spectra of flash radiographic sources are difficult to measure. The sources measured were Radiographic Integrated Test Stand-6 (370 rad at 1 m; 50 ns pulse) and Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) (550 rad at 1 m; 50 ns pulse). Features of the Compton spectrometer are described, and spectra are shown. Additional slides present data on instrumental calibration.

  8. 21 CFR 892.1880 - Wall-mounted radiographic cassette holder.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wall-mounted radiographic cassette holder. 892.1880 Section 892.1880 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... radiographic cassette holder. (a) Identification. A wall-mounted radiographic cassette holder is a device...

  9. Radiographic knee osteoarthritis in ex-elite table tennis players

    Directory of Open Access Journals (Sweden)

    Rajabi Reza

    2012-02-01

    Full Text Available Abstract Background Table tennis involves adoption of the semi-flexed knee and asymmetrical torsional trunk movements creating rotational torques on the knee joint which may predispose players to osteoarthritis (OA of the knee. This study aims to compare radiographic signs of knee OA and associated functional levels in ex-elite male table tennis players and control subjects. Methods Study participants were 22 ex-elite male table tennis players (mean age 56.64 ± 5.17 years with 10 years of involvement at the professional level and 22 non-athletic males (mean age 55.63 ± 4.08 years recruited from the general population. A set of three radiographs taken from each knee were evaluated by an experienced radiologist using the Kellgren and Lawrence (KL scale (0-4 to determine radiographic levels of OA severity. The intercondylar distance was taken as a measure of lower limb angulation. Participants also completed the pain, stiffness, and physical function categories of the Western Ontario and McMaster University Osteoarthritis Index (WOMAC 3.1 questionnaire. Results The results showed 78.3% of the ex-elite table tennis players and 36.3% of controls had varying signs of radiographic knee OA with a significant difference in the prevalence levels of definite radiographic OA (KL scale > 2 found between the two groups (P ≤ 0.001. Based on the WOMAC scores, 68.2% of the ex-elite table tennis players reported symptoms of knee pain compared with 27.3% of the controls (p = 0.02 though no significant differences were identified in the mean physical function or stiffness scores between the two groups. In terms of knee alignment, 73.7% of the ex-elite athletes and 32% of the control group had signs of altered lower limb alignment (genu varum (p = 0.01. Statistical differences were found in subjects categorized as having radiographic signs of OA and altered lower limb alignment (p = 0.03. Conclusions Ex-elite table tennis players were found to have increased

  10. MRI reporting by radiographers: Findings of an accredited postgraduate programme

    Energy Technology Data Exchange (ETDEWEB)

    Piper, Keith [Allied Heath Professions Department, Canterbury Christ Church University, North Holmes Road, Canterbury, Kent CT1 1QU (United Kingdom)], E-mail: keith.piper@canterbury.ac.uk; Buscall, Kaie [Allied Heath Professions Department, Canterbury Christ Church University, North Holmes Road, Canterbury, Kent CT1 1QU (United Kingdom); Thomas, Nigel [X-Ray Department, Trafford General Hospital, Manchester M41 5SL (United Kingdom)

    2010-05-15

    Aim: To analyse the objective structured examination (OSE) results of the first three cohorts of radiographers (n = 39) who completed an accredited postgraduate certificate (PgC) programme in reporting of general magnetic resonance imaging (MRI) investigations and to compare the agreement rates with those demonstrated for a small group of consultant radiologists. Method: Forty MRI investigations were used in the OSE which included the following anatomical areas and abnormal appearances: knee; meniscal/ligament injuries, bone bruises, effusions and osteochondral defects; lumbar spine: intervertebral disc morphology, vertebral collapse, tumours (bone and soft tissue), spinal stenosis and/or nerve root involvement; internal auditory meati (IAM): acoustic neuroma. Incidental findings included maxillary polyp, arachnoid cyst, renal cyst, hydroureter, pleural effusion and metastases (adrenal, lung, perirenal and/or thoracic spine). Sensitivity, specificity and total percentage agreement rates were calculated for all radiographers (n = 39) using all reports (n = 1560). A small representative subgroup of reports (n = 27) was compared to the three consultant radiologists' reports which were produced when constructing the OSE. Kappa values were estimated to measure agreement in four groups: consultant radiologists only; radiographers and each of the consultant radiologists independently. Results: The sensitivity, specificity and agreement rates for the three cohorts (combined) of radiographers were 99.0%, 99.0% and 89.2%, respectively. For the majority (5/9) of anatomical areas and/or pathological categories no significant differences (p < 0.05) were found between the mean Kappa scores (K = 0.47-0.76) for different groups of observers, whether radiographers were included in the group analysis or not. Where differences were apparent, this was in cases (4/9) where the variation was either not greater than found between radiologists and/or of no clinical significance

  11. Granulomatous colitis: findings on double contrast barium enema and follow-up studies

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jong Gi; Han, Joon Koo; Kim, Seung Hoon; Choo, Sung Wook; Kim, Seung Cheol; Choi, Byung Ihn [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the radiologic findings of granulomatous colitis on double contrast barium enema and changes on follow-up studies. Serial double contrast barium enema of six patients with granulomatous colitis confirmed by endoscopic biopsy were reviewed. We analyzed the radiologic findings and their follow-up changes, including aphthous ulcers, lymphoid hyperplasia, deep ulcers, cobble stone appearance, geographic ulcers, asymmetric involvement of ulcers, skip lesions, sinus tract, fistula formation, pseudosacculation, focal stricture, and small bowel involvement. Pretreatment double contrast barium enema findings were aphthous ulcers in five patients, deep ulcer in six, cobble stone appearance in five, longitudinal geographic ulcers in two, fistulas in one, pseudosacculations in two, focal stricture in one, and pseudopolyps in six. Also, anal ulcers were observed in two patients, asymmetric involvement of ulcers in three, skip lesions in four, and small bowel involvement in five in five patients proved to have inactive disease after treatment, aphthous ulcers and deep ulcers disappeared. Geographic ulcers of two patients and anal ulcer of one patients decreased in size or depth. Pseudosacculation in one patient disappeared. Pseudopolyps decreased in two patients, increased in one, and decreased after increase in two. One patient whose disease remained active after treatment showed maintenance or increase of ulcers or fistula. And their pseudosacculation or focal stricture unchanged and pseudopolyps decreased. The major radiologic findings of chronic granulomatous colitis on double contrast barium enema are aphthous ulcer, deep ulcer, cobble stone appearance, discontinuity of the lesion and coexistence of ulcers and pseudopolyps. And, double contrast barium enema is good follow-up modality because its findings correlate with clinical course of the granulomatous colitis after treatment.

  12. Influence of barium substitution on bioactivity, thermal and physico-mechanical properties of bioactive glass

    Energy Technology Data Exchange (ETDEWEB)

    Arepalli, Sampath Kumar, E-mail: askumar.rs.cer11@iitbhu.ac.in; Tripathi, Himanshu; Vyas, Vikash Kumar; Jain, Shubham; Suman, Shyam Kumar; Pyare, Ram; Singh, S.P., E-mail: spsinghceram@gmail.com

    2015-04-01

    Barium with low concentration in the glasses acts as a muscle stimulant and is found in human teeth. We have made a primary study by substituting barium in the bioactive glass. The chemical composition containing (46.1 − X) SiO{sub 2−}–24.3 Na{sub 2}O–26.9 CaO–2.6 P{sub 2}O{sub 5}, where X = 0, 0.4, 0.8, 1.2 and 1.6 mol% of BaO was chosen and melted in an electric furnace at 1400 ± 5 °C. The glasses were characterized to determine their use in biomedical applications. The nucleation and crystallization regimes were determined by DTA and the controlled crystallization was carried out by suitable heat treatment. The crystalline phase formed was identified by using XRD technique. Bioactivity of these glasses was assessed by immersion in simulated body fluid (SBF) for various time periods. The formation of hydroxy carbonate apatite (HCA) layer was identified by FTIR spectrometry, scanning electron microscope (SEM) and XRD which showed the presence of HCA as the main phase in all tested bioactive glass samples. Flexural strength and densities of bioactive glasses have been measured and found to increase with increasing the barium content. The human blood compatibility of the samples was evaluated and found to be pertinent. - Highlights: • In vitro bioactivity of soda-lime–baria-phospho-silicate glass was investigated. • HCA formed on surface of glasses was confirmed by XRD, SEM and FTIR spectrometry. • Mechanical properties of glasses were found to increase with barium addition. • Hemolysis showed that 1.2 mol% BaO bioactive glass exhibited better biocompatibility. • Barium substituted bioactive glasses can be used as bone implants.

  13. Scanning electron microscopic and electrophoretic observations on barium sulphate used to absorb clotting factors.

    Science.gov (United States)

    Howell, R M; Deacon, S L

    1975-04-30

    Electron microscopy and particle electrophoresis were found to be complementary techniques with which to complete the physical data from an earlier study on barium sulphates used to absorb clotting factors from serum. The differences revealed by scanning electron microscopy (S. E. M) in the physical shape of low and high density grades of barium sulphate particles appear to be of greater significance than charge as expressed by electrophoretic mobility, in determining whether or not precursor or performed factor Xa is eluted. This conclusion was based on the finding that at pH values close to 7, where the adsorption from serum occurs, all samples with the exception of natural barytes were uncharged. However as the high-density, or soil-grade, was found by S. E. M. to consist of large solid crystals it was suggested that this shape might induce activiation of factor X as a result of partial denaturation and consequent unfolding of the adsorbed protein. In contrast, uptake of protein into the centre of the porous aggregates revealed by S. E. M. pictures of low-density or X-ray grade barium sulphate may afford protection against denaturation and exposure of the enzyme site. The porous nature of particles of low-density barium sulphate compared with the solid crystalline forms of other grades accounts not only for its lower bulk density but also for its greater surface/gram ratio which is reflected by an ability to adsorb more protein from serum. Neither technique produced evidence from any of the samples to indicate the presence of stabilising agents sometimes used to coat particles in barium meals.

  14. STUDY OF EFFECTIVE TIME OF UNDILUTED FIXINGSOLUTIONS INLIGHTENING OF THE HIGH DENSITY PERIAPICAL RADIOGRAPHS

    Directory of Open Access Journals (Sweden)

    A ZAMANI NASER

    2003-12-01

    Full Text Available Introduction: Dental radiographs are occationally too dark because of different reasons such as over exposure, high concen-tration of developing solution and over development. Different chemicals are used to lighten these radiographs. In this research the undiluted fixed solution for the first time are tested and efficiency time of this solution in reducing the density of dark radiographs were evaluated. Method: Use of a dry mandible containing some teeth and 98 E speed periapical radiographs were prepared as foolow: A film wasexposed with 0.4 S... as positive control (ideal. 97 films were exposed with 1.8 S (dark and unreadable. Out of 97, one radiograph kept as positive control and remaining films prepared for study. All of radiographs developed and fixed with automatic processor in the same conditio. Out of 96 dark radiograph, 3 was used for pilot study and inserted in the undiluted fixing solution in different time. (2.5, 3 and 3.5 hrs. The result of pilot study showed that aii3 radiographs showed reductionin density and radiographs with her reduction time was closest to positive control for density and diognostic quality and radiograph with 2.5 hrs reduction time and 3.5 hre became darker and lighter as compared to positive control. The remaining 93 high density radiographs were divided into 3 groups, 31 in each group (group 1,2 and 3 first group 2.5 hrs, second 3 hrs and the third group 3.5 hrs were kept in undiluted fixed solution. for this, disposable glasses were used and in each glass a radiograph were inserted. The research time was spring and the temperature was about 2609 (without coolant. Evaluation of radiographs: For evaluation of radiographs 2 methods were used: First method used was: Densitometry: By this method the density of total lightened radiographs, positive control and negative control were determined. Another method was determined diagnostic quality of radiographs visually by radiologists, throng this way: Special

  15. THERMAL DECOMPOSITION MECHANISM OF BARIUM BENZOATE%苯甲酸钡的热分解机理

    Institute of Scientific and Technical Information of China (English)

    张克立; 袁继兵; 袁良杰; 孙聚堂

    1999-01-01

    Barium benzoate was synthesized in semi-solid phase reaction. The complex was characterized by elemental analysis, IR, X-ray powder diffraction. It is layered structure, monoclinic system. The mechanism of thermal decomposition for barium benzoate was studied by using TG, DTA, IR and gas chromatography-mass spectrometer. The thermal decompositon of barium benzoate in nitrogen proceeded in one stage: it decomposed to form BaCO3 and organic compounds. The organic compounds obtained from decomposition reaction are mainly benzophenone, triphenylmethane and so on.

  16. Obtaining of barium sulfate from solution formed after desulfation of the active mass of scrap lead-acid batteries

    Directory of Open Access Journals (Sweden)

    O. A. Kalko

    2014-03-01

    Full Text Available Analyses of literature data about processes for solution utilization formed after desulfation of the active mass of scrap lead-acid batteries is performed. Optimal conditions for obtaining of barium sulfate sediment from ammonium sulfate solute and chemically pure Ba(OH2×8H2O и BaCl2×2H2O were found experimentally. In laboratory the commercial barium sulfate from sulfate solutions, that are waste of recycling process of battery scrap, with application of chloride and barium hydroxide was production. The possibility of using this product were discussed.

  17. A Computer-Aided Detection System for Digital Chest Radiographs

    Directory of Open Access Journals (Sweden)

    Juan Manuel Carrillo-de-Gea

    2016-01-01

    Full Text Available Computer-aided detection systems aim at the automatic detection of diseases using different medical imaging modalities. In this paper, a novel approach to detecting normality/pathology in digital chest radiographs is proposed. The problem tackled is complicated since it is not focused on particular diseases but anything that differs from what is considered as normality. First, the areas of interest of the chest are found using template matching on the images. Then, a texture descriptor called local binary patterns (LBP is computed for those areas. After that, LBP histograms are applied in a classifier algorithm, which produces the final normality/pathology decision. Our experimental results show the feasibility of the proposal, with success rates above 87% in the best cases. Moreover, our technique is able to locate the possible areas of pathology in nonnormal radiographs. Strengths and limitations of the proposed approach are described in the Conclusions.

  18. A novel approach to radiographic image resolution gauge fabrication

    Science.gov (United States)

    Trivelpiece, C. L.; Babcox, B. L.; Brenizer, J. S.; Wolfe, D. E.; Adair, J. H.

    2011-08-01

    A resolution gauge was fabricated for measuring the spatial resolution of radiographic imaging systems. Silicon wafers, 100 mm , were patterned using standard contact lithography and the patterned features were etched using deep reactive ion etching (DRIE). The smallest features were 5 μm wide line pairs. The resulting etched trenches included aspect ratios of up to 10:1 and were 40.6±0.2 μm deep. The etch rate was 2.7 μm/min for the reported etch depth. A Gd 2O 3 nanopowder was dispersed into a slurry using Darvan C and water as the dispersant and solvent, respectively. A rapid infiltration method was used to fill the etched trenches with the slurry. Neutron and X-ray radiographs of the resolution gauge and the results demonstrate that the prototype gauge would be a suitable standard for measuring the spatial resolution of both X-ray and neutron radiography systems.

  19. Radiographically Occult and Subtle Fractures: A Pictorial Review

    Directory of Open Access Journals (Sweden)

    Mohamed Jarraya

    2013-01-01

    Full Text Available Radiographically occult and subtle fractures are a diagnostic challenge. They may be divided into (1 “high energy trauma fracture,” (2 “fatigue fracture” from cyclical and sustained mechanical stress, and (3 “insufficiency fracture” occurring in weakened bone (e.g., in osteoporosis and postradiotherapy. Independently of the cause, the initial radiographic examination can be negative either because the findings seem normal or are too subtle. Early detection of these fractures is crucial to explain the patient’s symptoms and prevent further complications. Advanced imaging tools such as computed tomography, magnetic resonance imaging, and scintigraphy are highly valuable in this context. Our aim is to raise the awareness of radiologists and clinicians in these cases by presenting illustrative cases and a discussion of the relevant literature.

  20. Computer assisted measurement of femoral cortex thickening on radiographs

    Science.gov (United States)

    Yao, Jianhua; Liu, Yixun; Chen, Foster; Summers, Ronald M.; Bhattacharyya, Timothy

    2013-03-01

    Radiographic features such as femoral cortex thickening have been frequently observed with atypical subtrochanteric fractures. These features may be a valuable finding to help prevent fractures before they happen. The current practice of manual measurement is often subjective and inconsistent. We developed a semi-automatic tool to consistently measure and monitor the progress of femoral cortex thickening on radiographs. By placing two seed points on each side of the femur, the program automatically extracts the periosteal and endosteal layers of the cortical shell by active contour models and B-spline fitting. Several measurements are taken along the femur shaft, including shaft diameter, cortical thickness, and integral area for medial and lateral cortex. The experiment was conducted on 52 patient datasets. The semi-automatic measurements were validated against manual measurements on 52 patients and demonstrated great improvement in consistency and accuracy (p<0.001).

  1. Stress radiographs in the evaluation of degenerative femorotibial joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Tallroth, K.; Lindholm, T.S.

    1987-11-01

    Thirty-eight osteoarthrotic knees were examined to assess the widths of the femorotibial joint spaces. Radiographs were exposed with the patient lying, in a standing position, and with an adduction and abduction force. Forced compression of the osteoarthrotic joint compartment caused, on average, 18% greater narrowing than when loading it in the standing position. Compared to the joint space at rest, the non-weight-bearing compartment widened by 16% in the standing position and narrowed by 20% when stress was applied. Furthermore, the results showed an increase in laxity proportional to the degree of arthrosis. Stress radiographs significantly display the real cartilage width of both joint compartments. Knowledge of the condition of the articular cartilage in the non-weight-bearing compartment is important when considering a transfer of loading stresses by means of osteotomy. (orig.)

  2. Radiographic findings in type 3 b Gaucher disease

    Energy Technology Data Exchange (ETDEWEB)

    Hill, S.C. [Diagnostic Radiology Department, National Institutes of Health, Bethesda, MD (United States); Damaska, B.M. [Diagnostic Radiology Department, National Institutes of Health, Bethesda, MD (United States); Tsokos, M. [Laboratory of Pathology, National Institutes of Health, Bethesda, MD (United States); Kreps, C. [Developmental and Metabolic Neurology Branch, National Institutes of Health, Bethesda, MD (United States); Brady, R.O. [Developmental and Metabolic Neurology Branch, National Institutes of Health, Bethesda, MD (United States); Barton, N.W. [Developmental and Metabolic Neurology Branch, National Institutes of Health, Bethesda, MD (United States)

    1996-12-01

    The purpose of this paper is to describe the radiographic findings in type 3 b Gaucher disease, a chronic neuronopathic form of the illness with severe systemic manifestations. Between 1980 and 1985 17 consecutive patients were evaluated with radiography of the chest, long bones and spine, CT of the head and chest, abdominal sonography, and MRI of the head, abdomen and spine. Clinical manifestations were severe, and led to death from hepatic, pulmonary or cardiac failure in nine patients. Type 3 b Gaucher disease shares the same spectrum of radiographic findings observed in type 1 disease, but the systemic manifestations are more severe. Pulmonary infiltrates, thoracic lymph node enlargement, vertebral compression fractures and osteonecrosis of the long bones occur much more frequently in patients with type 3 b disease. (orig.). With 7 figs., 2 tabs.

  3. Defining and assessing critical thinking skills for student radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Castle, Alan [University of Portsmouth, School of Health Sciences and Social Work, Centre for Radiography Education, James Watson Building, 2 King Richard 1st Road, Portsmouth PO1 2FR (United Kingdom)], E-mail: alan.castle@port.ac.uk

    2009-02-15

    Developing critical thinking skills is a key aim of higher education and is important in preparing student radiographers for their future careers in clinical practice. The aim of this paper was to attempt to devise and assess six key components of critical thinking appropriate for radiographic practice. Each of the six components was divided into three dimensions and a Critical Thinking Skills Scoring Chart (CTSSC) devised to assess students' written performance against each dimension. Scores revealed that approximately 30% of students were rated as good and approximately 10% of students were rated as poor in each component, although there was some variability between different dimensions. It is suggested that educators need to encourage and support students to develop their critical thinking skills by reviewing their curriculum to clearly define specific skills and ensure that they are appropriately taught and assessed.

  4. Preliminary experimental research for silver recovery from radiographic films

    Science.gov (United States)

    Cânda, L. R.; Ardelean, E.

    2017-01-01

    Global demand for silver remains steadily to about 1,000 million ounces (28349500 kg), of which around 600 million ounces (17009700 kg) are used in industrial applications. Extraction of silver from the ore is expensive and harmful to the environment and low efficiency. X-ray films represent an important worldwide consumer as research on recovery of silver from exposed radiographic films must be oriented to achieve a maximum recovery and a high purity silver, with methods through the by-products will be less polluting for the environment. The paper presents some laboratory tests referring to the recovery of silver from radiographic films by leaching with sodium hydroxide. Two series of experiments were performed with different amounts of used X-ray film.

  5. Image enhancement of digital periapical radiographs according to diagnostic tasks

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Cheonan (Korea, Republic of)

    2014-03-15

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  6. Detection of tuberculosis using hybrid features from chest radiographs

    Science.gov (United States)

    Fatima, Ayesha; Akram, M. Usman; Akhtar, Mahmood; Shafique, Irrum

    2017-02-01

    Tuberculosis is an infectious disease and becomes a major threat all over the world but still diagnosis of tuberculosis is a challenging task. In literature, chest radiographs are considered as most commonly used medical images in under developed countries for the diagnosis of TB. Different methods have been proposed but they are not helpful for radiologists due to cost and accuracy issues. Our paper presents a methodology in which different combinations of features are extracted based on intensities, shape and texture of chest radiograph and given to classifier for the detection of TB. The performance of our methodology is evaluated using publically available standard dataset Montgomery Country (MC) which contains 138 CXRs among which 80 CXRs are normal and 58 CXRs are abnormal including effusion and miliary patterns etc. The accuracy of 81.16% was achieved and the results show that proposed method have outperformed existing state of the art methods on MC dataset.

  7. Radiographic workload and use factors for orthopedic facilities

    Energy Technology Data Exchange (ETDEWEB)

    Bushong, S.C.; Glaze, S.A.

    1983-01-01

    Observations of technique factors at 9 radiographic installations dedicated to orthopedic radiography have been made. Monthly area radiation measurements with thermoluminescent dosimeters were made at three of these facilities. The results of these observations and measurements suggest that current NCRP recommended assumptions utilized in protective barrier computations result in considerably more shielding than is necessary. We observed an average workload of 224 mA min/wk and a maximum weekly average of 670 mA min/wk. The use factor for the chest wall averaged 5%. That for all other vertical barriers was less than 1%. The average operating potential was 75 kVp. Room radiation measurements confirm the suggestion that at least two of the walls and the control booth barrier in an orthopedic radiographic facility may be considered secondary barriers.

  8. Development and resolution of radiographic lesions in canine heartworm disease.

    Science.gov (United States)

    Rawlings, C A; Losonsky, J M; Lewis, R E; McCall, J W

    1981-06-01

    Thoracic radiography of 7 Beagles was performed before heartworm infection, during a 1-year heartworm infection, and for 1 year following appropriate treatment. Cardiac and vascular lesions on thoracic radiographs were compared with angiographic changes. Within 3 months of obstructed blood flow in the caudal lobar arteries, associated increased focal parenchymal densities were detected. These lesions were regarded as characteristic of heartworm disease. Although the most severe arteriographic changes were in the caudal lobar arteries, lobar arterial changes on a lateral view were best detected in the right cranial lobar artery. These arteries increased in size during infection and decreased in size after treatment. It was concluded that the dorsoventral view is best for evaluation of the caudal lobar arteries. The most marked parenchymal lesions were detected during the first 6 months following adulticide treatment. These lesions and the other radiographic alterations then decreased in severity. Persistence of the parenchymal lesions were related to persistence of heartworm infection.

  9. Development of Automatic Extraction Weld for Industrial Radiographic Negative Inspection

    Institute of Scientific and Technical Information of China (English)

    张晓光; 林家骏; 李浴; 卢印举

    2003-01-01

    In industrial X-ray inspection, in order to identify weld defects automatically, raise the identification ratio, and avoid processing of complex background, it is an important step for sequent processing to extract weld from the image. According to the characteristics of weld radiograph image, median filter is adopted to reduce the noise with high frequency, then relative gray-scale of image is chosen as fuzzy characteristic, and image gray-scale fuzzy matrix is constructed and suitable membership function is selected to describe edge characteristic. A fuzzy algorithm is adopted for enhancing radiograph image processing. Based on the intensity distribution characteristic in weld, methodology of weld extraction is then designed. This paper describes the methodology of all the weld extraction, including reducing noise, fuzzy enhancement and weld extraction process. To prove its effectiveness, this methodology was tested with 64 weld negative images available for this study. The experimental results show that this methodology is very effective for extracting linear weld.

  10. Comparison of vertebrae and otoliths measured directly and from radiographs

    DEFF Research Database (Denmark)

    Pedersen, Jens

    1997-01-01

    It is general practice among fish ecologists to use indigestible remains such as vertebrae and otoliths in fish stomachs to determine the nature and size of their prey. However, estimation of the relationship between fish length and vertebrae size is a time consuming process when using vertebrae ...... was established at least 10 times faster using radiographs than when direct measurements were used. (C) 1997 Elsevier Science B.V....

  11. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Lagisetty, Jyothi [Memorial Hermann Medical Center, Emergency Medicine Department, Houston, TX (United States); Slovis, Thomas [Wayne State University School of Medicine, Department of Radiology, Pediatric Imaging, Children' s Hospital of Michigan, Detroit, MI (United States); Thomas, Ronald [Children' s Hospital of Michigan, Wayne State University of Medicine, Department of Pediatrics, Detroit, MI (United States); Knazik, Stephen; Stankovic, Curt [Wayne State University of Medicine, Division of Emergency Medicine, Children' s Hospital of Michigan, Detroit, MI (United States)

    2012-07-15

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS <14, positive urinalysis, abdominal pain/tenderness, femur fracture) and five high-risk mechanisms of injury (unrestrained motor vehicle collision [MVC], MVC with ejection, MVC rollover, auto vs. pedestrian, auto vs. bicycle). Pelvic fractures in pediatric major blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients. (orig.)

  12. Radiographic Images Produced by Cosmic-Ray Muons

    Science.gov (United States)

    Alfaro, Rubén

    2006-09-01

    An application of high energy physics instrumentation is to look for structure or different densities (materials) hidden in a matrix (tons) of material. By tracing muons produced by primary Cosmic Rays, it has been possible to generate a kind of radiographs which shows the inner structure of dense containers, monuments or mountains. In this paper I review the basics principles of such techniques with emphasis in the Sun Pyramid project, carried out by IFUNAM in collaboration with Instituto Nacioanal de Antropologia e Historia.

  13. Radiographic appearance of a post-epidural headache.

    LENUS (Irish Health Repository)

    Weekes, G

    2012-02-01

    We report the case of a 35-year-old lady who presented with a 6-day history of a postural headache following an uncomplicated epidural catheter insertion. Meningitis was initially suspected and a neurology review was obtained. CT and MRI brain revealed features suggestive of meningitis. However these radiological features are also consistent with post dural puncture headache (PDPH). This case highlights the under reported and possible misleading radiographical features of PDPH.

  14. Radiographic Evidence of Femoroacetabular Impingement in Athletes With Athletic Pubalgia

    OpenAIRE

    Economopoulos, Kostas J.; Milewski, Matthew D.; Hanks, John B.; Hart, Joseph M.; Diduch, David R.

    2014-01-01

    Background: Two of the most common causes of groin pain in athletes are femoroacetabular impingement (FAI) and athletic pubalgia. An association between the 2 is apparent, but the prevalence of radiographic signs of FAI in patients undergoing athletic pubalgia surgery remains unknown. The purpose of this study was to determine the prevalence of radiologic signs of FAI in patients with athletic pubalgia. Hypothesis: We hypothesized that patients with athletic pubalgia would have a high prevale...

  15. Diabetic Mastopathy as a Radiographically Occult Palpable Breast Mass

    OpenAIRE

    Uma Thanarajasingam; Beiyun Chen; Tortorelli, Cindy L.; Jakub, James W.; Karthik Ghosh

    2011-01-01

    Diabetic mastopathy is an uncommon, benign disease of the breast that can occur in women with diabetes and clinically mimic breast cancer. We describe a patient with long-standing type 1 diabetes who presented with a palpable breast mass with negative imaging findings on mammography, ultrasonography, and breast MRI. Surgical biopsy and histopathology confirmed diabetic mastopathy. We use this case to highlight the recognition, radiographic features, pathology, and management of this benign br...

  16. [Radiographic manifestations in teeth and jaws in chronic kidney insufficiency].

    Science.gov (United States)

    Scutellari, P N; Orzincolo, C; Bedani, P L; Romano, C

    1996-10-01

    Forty-five patients affected with chronic renal failure (29 men and 16 women; mean age: 47.8 years), treated with hemodialysis for 4 to 245 months (mean: 66.9 months) were examined with panoramic and skeletal radiographs-the latter of the skull, hands, shoulders and clavicles, pelvis and spine. The control group (45 subjects with no renal diseases) was examined only with panoramic radiography. Dental and skeletal radio-graphs were given an 0-6 score and then compared to assess a possible relationship between skeletal and dental changes at radiography. Twenty-six dialysis patients (57.7%) had radiographic abnormalities in the maxillary bones-i.e., osteoporosis (100% of patients), focal osteosclerosis adjacent to the roots (11.5%), lamina dura reduction or loss (26.9%), calcifications of soft tissues or salivary glands (15.3%) and brown tumors (7.6%). In the teeth of dialysis patients, the dental pulp chamber was narrowed in 11.1% and hypercementosis of the roots was observed in 4.5%. Radiographic abnormalities in the hand, shoulder and pelvis were depicted in 51.1% of dialysis patients-in 86.9% of them with maxillary lesions. In the control group, 15.5% had mandibular bone lesions-i.e., osteopenia, cortex reduction at the mandibular angles and cyst-like lesions -but the evidence of caries and periodontal disease did not differ from that in the dialysis group. The diagnosis and follow-up of dialysis patients are currently made with serum biochemistry, radiography and histology. The purpose of skeletal radiology is to monitor the progression or regression of musculoskeletal abnormalities. Panoramic radiography might be useful in monitoring renal osteodystrophy, especially to assess the response to therapy-i.e., parathyroidectomy, calcium or vitamin-D therapy and renal transplant.

  17. Imaging of adult flatfoot: correlation of radiographic measurements with MRI.

    Science.gov (United States)

    Lin, Yu-Ching; Mhuircheartaigh, Jennifer Ni; Lamb, Joshua; Kung, Justin W; Yablon, Corrie M; Wu, Jim S

    2015-02-01

    OBJECTIVE. The purpose of this study is to determine whether radiographic foot measurements can predict injury of the posterior tibial tendon (PTT) and the supporting structures of the medial longitudinal arch as diagnosed on MRI. MATERIALS AND METHODS. After institutional review board approval, 100 consecutive patients with radiographic and MRI examinations performed within a 2-month period were enrolled. Thirty-one patients had PTT dysfunction clinically, and 69 patients had other causes of ankle pain. Talonavicular uncoverage angle, incongruency angle, calcaneal pitch angle, Meary angle, cuneiform-to-fifth metatarsal height, and talar tilt were calculated on standing foot or ankle radiographs. MRI was used to assess for abnormalities of the PTT (tenosynovitis, tendinosis, and tear) and supporting structures of the medial longitudinal arch (spring ligament, deltoid ligament, and sinus tarsi). Statistical analysis was performed using the chi-square and Fisher exact tests for categoric variables; the Student t test was used for continuous variables. RESULTS. There was a statistically significant association of PTT tear with abnormal talonavicular uncoverage angle, calcaneal pitch angle, Meary angle, and cuneiform-to-fifth metatarsal height. PTT tendinosis and isolated tenosynovitis had a poor association with most radiologic measurements. If both calcaneal pitch and Meary angles were normal, no PTT tear was present. An abnormal calcaneal pitch angle had the best association with injury to the supporting medial longitudinal arch structures. CONCLUSION. Radiographic measurements, especially calcaneal pitch and Meary angles, can be useful in detecting PTT tears. Calcaneal pitch angle provides the best assessment of injury to the supporting structures of the medial longitudinal arch.

  18. Topographical evaluation of the mandibular canal through panoramic radiograph

    Directory of Open Access Journals (Sweden)

    Ingrid Macedo Oliveira

    2016-10-01

    Full Text Available The mandibular canal is located inside the body of the mandible and may have anatomical variations. The topographic knowledge of the mandibular canal by the Dental surgeons is fundamental to achieving success in surgical planning, anesthetics and clinical interventions involving the jaw. To study the anatomy of the mandibular canal through panoramic radiographs. A retrospective descriptive study, developed after review and approval by the Ethics and Research Committee with the number of opinion 431095. Were analyzed 252 panoramic radiographs of patients of male and female attended in dental clinics UNINOVAFAPI University Center, Teresina-Pi, Brazil. The radiographs were analyzed with the aid of a light box and each antimere the jaw was observed separately. The classification of Nortjé and Langlais for description of the topography of the mandibular canal were used. Descriptive statistical analysis was performed with SPSS version 18.0. There was a prevalence of 38.89% in both antimeres, of mandibular channel the Type II. The type IV was present in 25.4% in the right hemi-arch and 26.6% on the left. Mandibular canal with unilateral bifurcation was observed in 0.77% of the sample and molar straight channel has not been identified. We observed anatomical variations as for the number and path, of the mandibular canal with the highest prevalence of Types II and IV, and the absence of bifurcations. Most was mandibular channels showed no bifurcation. The panoramic radiograph showed up an aid important to identify the mandibular canal and its variations.

  19. The uptake of Continuing Professional Development (CPD) by Ghanaian radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Gawugah, James N.K., E-mail: jgawugah@hotmail.com [School of Allied Health Sciences, College of Health Sciences, P.O. Box KB 143, Korle-Bu, Accra (Ghana); Jadva-Patel, Hansa; Jackson, Marcus T. [Kingston University and St. George' s Hospital Medical School, Faculty of Health and Social Care Science, School of Radiography, Penrhyn Road, Kingston Upon Thames, Surrey KT1 2EE (United Kingdom)

    2011-11-15

    Continuing professional development (CPD) currently gains a priority within healthcare professions all over the globe. It is playing important roles in achieving improved quality care delivery. Healthcare practitioners are expected to continuously undertake CPD to maintain, enhance and improve quality of service delivery to meet the consumers' expectations. CPD offers practitioners the opportunity to retain and enhance the basic knowledge and skills through their working life; thus enhancing competency within one's professional range of practice. In Ghana, awareness of CPD participation has not been created among healthcare practitioners to enable them engage in effective CPD activities in order to improve their knowledge and skills. Purpose: To examine the level of radiographers' participation in CPD activities in Ghana. Method: A 21-item questionnaire was constructed to collect data from 80 participants drawn from among radiographers currently practising in the radiology/X-ray departments of the ten regional hospitals in Ghana. The questionnaire comprised of 3 sections: demographics, CPD and education specific sections. Out of 80 questionnaires administered, 42 were completed and returned representing 52.5%. Out of the percentage, 74% were males and 26% females. The findings highlight that majority (44%) of the participants are currently within the age group of 31-40 years, while 2% is/are 60 or more years. The article also reveals that the radiographers have access to few peer review journals which serve as sources of information on contemporary issues in radiography and CPD learning activities. Again, a generally poor level of CPD awareness among the Ghanaian radiographers has been established. Lack of effective recording of learning and CPD activities have also been revealed. Conclusion: The article concludes by recommending CPD policy guidelines; a regulatory body to register all healthcare professionals under one body to ensure effective CPD

  20. Radiographic signs of open median sternotomy in neonates and infants

    Energy Technology Data Exchange (ETDEWEB)

    Wu, George [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Geisinger Medical Center, Danville, PA (United States); Jaimes, Camilo; Markowitz, Richard I. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Gaynor, J.W. [The Children' s Hospital of Philadelphia, Department of Surgery, Philadelphia, PA (United States)

    2012-06-15

    Leaving the median sternotomy wound open following cardiac surgery is employed to avoid cardiovascular compression. Horizontal struts can be used. Radiologists interpreting portable radiographs might be unaware of the open median sternotomy (OMS). To describe the frequency of radiographic signs of OMS and to increase awareness among radiologists to prevent misdiagnosis of pneumothorax and pneumomediastinum. Radiographs of 41 infants (17 girls/24 boys) with OMS were studied (age range 2 days to 8 months, mean 33 days). Central lucency and sternal edges were noted. Interclavicular distances before and after sternotomy were compared. Central lucency was seen in 25/41 (61%) children. Sternal struts were apparent in 27 (66%). In 14 without struts, central lucency was present in 8 (57%). In 27 children with struts, central lucency was present in 17 (63%) and absent in 10 (37%). Split sternal centers were identified in 6/41 (15%). The mean interclavicular distance was 23.5 mm (SD = 4.39) before sternotomy and 38.2 mm (SD = 7.0 mm) after sternotomy (P < 0.001). OMS has characteristic signs in the majority of cases. Recognition of these findings is useful and can prevent misinterpretation. (orig.)

  1. Symptomatic sacroiliac joint disease and radiographic evidence of femoroacetabular impingement.

    Science.gov (United States)

    Morgan, Patrick M; Anderson, Anthony W; Swiontkowski, Marc F

    2013-01-01

    Symptomatic sacroiliac (SI) joint disease is poorly understood. The literature provides no clear aetiology for SI joint pathology, making evaluation and diagnosis challenging. We hypothesised that patients with documented sacroiliac pain might provide insight into the aetiology of these symptoms. Specifically, we questioned whether SI joint symptoms might be associated with abnormal hip radiographs. We reviewed the pelvic and hip radiographs of a prospectively collected cohort of 30 consecutive patients with SI joint pathology. This database included 33 hips from 30 patients. Radiographic analysis included measurements of the lateral centre edge angle, Tönnis angle, and the triangular index, of the ipsilateral hip. Evidence for retrotorsion of the hemipelvis was recorded. Hips were graded on the Tönnis grading system for hip arthrosis. In this cohort 14/33 (42%) of hips had evidence of significant osteoarthrosis indicated by Tönnis grade 2 or greater and 15/33 (45%) displayed subchondral cyst formation around the hip or head neck junction. In assessing acetabular anatomy, 21% (7/33) had retroversion, 12% (4/33) had a lateral centre edge angle >40° with 3% (1/33) >45°. Tönnis angle was arthrosis. The clinician should maintain FAI in the differential diagnosis when investigating patients with buttock pain.

  2. Compliance of Michigan dentists with radiographic safety recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Nakfoor, C.A.; Brooks, S.L. (University of Michigan School of Dentistry, Ann Arbor (United States))

    1992-04-01

    We surveyed a random sample of 398 Michigan dentists in private practice to determine their compliance with the American Dental Association Council's recommendations for radiographic equipment and techniques. The response rate was 67% of the questionnaires delivered successfully. The majority of dentists use only D-speed film (73%) and round collimation of the x-ray beam (90%). Only 5% have an x-ray machine equipped with a rectangular collimator and 18% have at least one machine with a pointed cone. Leaded apron use is almost universal, but only 49% of the dentists use cervical collars in addition to the apron. The majority of dentists surveyed do not comply with the American Dental Association Council's recommendations on film speed, collimation, and use of leaded cervical collar. Using effective dose equivalents determined by Gibbs et al. for a variety of radiographic techniques, we estimate that an eight-fold reduction in radiation dose could be achieved without eliminating a single radiograph if all dentists used E-speed film and collimation of the beam to the size of the film.

  3. Radiographic parameters of the hip joint from birth to adolescence

    Energy Technology Data Exchange (ETDEWEB)

    Than, P.; Kranicz, J.; Bellyei, A. [Dept. of Orthopaedics, Univ. of Pecs, Medical Faculty, Ifjusag utja (Hungary); Sillinger, T. [Dept. of Orthopaedics, Szt Gyorgy County Hospital, Szekesfehervar (Hungary)

    2004-03-01

    Background: Various qualitative and quantitative radiological geometrical parameters can be of great help when assessing dysplasia of the hip joint and in understanding developmental processes of the infant hip. There are few data on the normal values of the hip joint at different ages. Objective: To perform radiographic measurements on hip joints considered to be anatomically normal and to provide data for each age group, thus describing features of the radiographic development of the hip. Materials and methods: Radiographs were examined from 355 children (age 0-16 years) undergoing examination for scoliosis (long film), urography or plain abdominal radiography. Qualitative and quantitative signs were observed and measured, focusing on the Hilgenreiner, Wiberg and Idelberger angles and the decentric distance. Results: Before the age of 9 years measurable data from neighbouring age groups differed significantly, indicating typical radiological changes of the joint. For the same age range, qualitative changes could also be observed. After 9 years of age, radiological development of the normal hip joint during childhood is much slower. (orig.)

  4. Application of Perona Malik anisotropic diffusion on digital radiographic image

    Energy Technology Data Exchange (ETDEWEB)

    Halim, Suhaila Abd; Razak, Rohayu Abdul; Ibrahim, Arsmah [Center of Mathematics Studies, Faculty of Computer and Mathematical Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor DE (Malaysia); Manurung, Yupiter HP [Advanced Manufacturing Technology Center, Faculty of Mechanical Engineering, Universiti Teknologi MARA, 40450 Shah Alam, Selangor DE (Malaysia)

    2014-07-10

    Perona Malik Anisotropic Diffusion (PMAD) is a very useful and efficient denoising technique if the parameters are properly selected. Overestimating the parameters may cause oversmoothed and underestimating it may leave unfiltered noise. This makes the selection of parameters a crucial process. In this paper the PMAD model is solved using a finite difference scheme The discretized model is evaluated using different diffusion coefficient of exponential and quadratic on defective radiographic images in terms of quality and efficiency. In the application of the PMAD model on image data, a set of defective radiographic images of welding is used as input data. Peak Signal to Noise Ratio (PSNR), Structural Similarity Measure (SSIM) and temporal time are used to evaluate the performance of the model. The implementation of the experiment has been carried out using MATLAB R2009a. In terms of quality, results show that the Quadratic Diffusion Coefficient Function (QDCF) provides better results compared with the Exponential Diffusion Coefficient Function (EDCF). In conclusion, the denoising effect using PMAD model based on finite difference scheme shows able to improve image quality by removing noise in the defective radiographic image.

  5. Radiographic characterization of primary lung tumors in 74 dogs.

    Science.gov (United States)

    Barrett, Laura E; Pollard, Rachel E; Zwingenberger, Allison; Zierenberg-Ripoll, Alexandra; Skorupski, Katherine A

    2014-01-01

    Primary pulmonary neoplasia is well recognized in dogs and prognosis depends upon the tumor type. The purpose of this retrospective study was to characterize the radiographic appearance of different primary lung tumors with the goal of establishing imaging criteria to separate the different types. Three-view thoracic radiographs of 74 dogs with histologically confirmed pulmonary anaplastic carcinoma (n = 2), adenocarcinoma (n = 31), bronchioalveolar carcinoma (n = 19), histiocytic sarcoma (n = 21), and squamous cell carcinoma (n = 1) were evaluated. Radiographs were assessed for tumor volume, affected lobe, location within lobe, overall pulmonary pattern, presence of cavitation, mineralization, air bronchograms, lymphadenomegaly, and pleural fluid. Histiocytic sarcomas were significantly larger than other tumor types (271 cm(3); P = 0.009) and most likely to be found in the left cranial (38%; 8/21) and right middle (43%; 9/21) lung lobes, whereas adenocarcinomas were most likely to be found in the left caudal (29%; 9/31) lung lobe. Fifty-seven percent (12/21) of histiocytic sarcomas had an internal air bronchogram. Findings indicate that a large mass in the periphery or affecting the whole lobe of the right middle or left cranial lung lobe with an internal air bronchogram is likely to be an histiocytic sarcoma.

  6. Hybrid object detection system for x-ray radiographs

    Science.gov (United States)

    Vita, Joshua A.; Wantuch, Andrew C.; Jimenez, Edward S.; Bray, Iliana E.

    2016-10-01

    While object detection is a relatively well-developed field with respect to visible light photographs, there are significantly fewer algorithms designed to work with other imaging modalities. X-ray radiographs have many unique characteristics that introduce additional challenges that can cause common image processing and object detection algorithms to begin to fail. Examples of these problematic attributes include the fact that radiographs are only represented in gray scale with similar textures and that transmission overlap occurs when multiple objects are overlaid on top of each other. In this paper we not only analyze the effectiveness of common object detection techniques as applied to our specific database, but also outline how we combined various techniques to improve overall performance. While significant strides have been made towards developing a robust object detection algorithm for use with the given database, it is still a work in progress. Further research will be needed in order to deal with the specific obstacles posed by radiographs and X-ray imaging systems. Success in this project would have disruptive repercussions in fields ranging from medical imaging to manufacturing quality assurance and national security.

  7. Interaction between a perfluorocarbon emulsion and radiographic contrast media.

    Science.gov (United States)

    Franke, Ralf-Peter; Reuter, Peter; Röhlke, Wolfgang; Matschke, Klaus; Keller, Steffi; Klosterhalfen, Bernd; Mittermayer, Christian; Mrowietz, Christoph; Jung, Friedrich

    2004-03-01

    This study evaluated specially designed perfluorocarbon (PFC) emulsions as blood substitutes in case of induced ischemia of the left heart ventricle in healthy farm pigs. Two hundred ml of perfluorocarbon emulsion were infused while 200 ml of blood were simultaneously drawn. Radiographic contrast media were given to aid placement of balloon catheters in the left coronary artery. Histopathological analysis showed that right heart failure caused the deaths of both pigs. Particles (up to>3 micro) of foreign body materials obstructed capillaries of all organs analyzed (heart, lung, liver, kidneys and spleen). Laboratory investigation showed severe interference between the PFC emulsion and radiographic contrast media, resulting in the deterioration of the PFC emulsion. The strongest interference occurred when PFC emulsion and Accupaque interacted; particle size started at an initial 311 nm and went up to >3 micro within seconds. Great care must be taken when PFC emulsions are used in combination with x-ray contrast media. None of the described radiographic contrast media should be used within 48 hours prior to the use of this PFC emulsion. Also, the use of these contrast media should be avoided for a certain period of time after using PFC emulsion. The mechanisms of elimination of PFC emulsions from the circulation are not completely understood and has yet to be evaluated.

  8. Digital processing of radiographic images from PACS to publishing.

    Science.gov (United States)

    Christian, M E; Davidson, H C; Wiggins, R H; Berges, G; Cannon, G; Jackson, G; Chapman, B; Harnsberger, H R

    2001-03-01

    Several studies have addressed the implications of filmless radiologic imaging on telemedicine, diagnostic ability, and electronic teaching files. However, many publishers still require authors to submit hard-copy images for publication of articles and textbooks. This study compares the quality digital images directly exported from picture archive and communications systems (PACS) to images digitized from radiographic film. The authors evaluated the quality of publication-grade glossy photographs produced from digital radiographic images using 3 different methods: (1) film images digitized using a desktop scanner and then printed, (2) digital images obtained directly from PACS then printed, and (3) digital images obtained from PACS and processed to improve sharpness prior to printing. Twenty images were printed using each of the 3 different methods and rated for quality by 7 radiologists. The results were analyzed for statistically significant differences among the image sets. Subjective evaluations of the filmless images found them to be of equal or better quality than the digitized images. Direct electronic transfer of PACS images reduces the number of steps involved in creating publication-quality images as well as providing the means to produce high-quality radiographic images in a digital environment.

  9. The impact of work rewards on radiographers' organizational commitment.

    Science.gov (United States)

    Akroyd, D; Mulkey, W; Utley-Smith, Q

    1995-01-01

    Organizational commitment is an affective work outcome that has been used to predict work-related behaviors such as turnover, absenteeism and intent-to-leave. There has been little research in organizational commitment for the allied health professions and no empirical studies in the radiologic sciences. The purpose of this study was to examine the predictive value of selected intrinsic and extrinsic work reward variables--involvement, significance, autonomy, general working conditions, supervision and salary--on staff radiographers' organizational commitment. In this study of 600 full-time staff radiographers in North and South Carolina, supervision (for ages 20-37 years) and involvement (for ages 38-66 years) were significant predictors of organizational commitment. The results of the study indicate that healthcare organizations should provide potential supervisors with managerial training, especially for radiographers who move to supervisory positions based on clinical skills and years of experience. In the long run, such programs are much less expensive than costs associated with replacing employees who leave the organization because of low organizational commitment. Also, management strategies and programs to redesign and enhance job tasks may help maintain or increase organizational commitment.

  10. The radiographic features of rheumatoid arthritis in HLA-B27-positive patients

    Energy Technology Data Exchange (ETDEWEB)

    Rundback, J.H. (Dept. of Radiology, Beth Israel Medical Center, New York, NY (United States)); Rosenberg, Z.S. (Dept. of Radiology, Hospital for Joint Diseases, Orthopaedic Inst., New York, NY (United States)); Solomon, G. (Dept. of Rheumatology, Hospital for Joint Diseases, Orthopaedic Institute, New York, NY (United States))

    1993-05-01

    Radiographs were reviewed in a group of nine patients with classical seropositive rheumatoid arthritis who on tissue typing were found to express the class I HLA-B27 allele. Radiographs were analyzed with regard to whether or not they demonstrated radiographic features of (1) classical rheumatoid arthritis, (2) seronegative arthritis, or (3) mixed features of rheumatoid and seronegative arthritis. Five patients (55%) displayed radiographic features consistent with a diagnosis of rheumatoid arthritis, two patients (22%) showed radiographic features of seronegative disorder (periostitis and sacroiliitis), and two patients (22%) showed a mixed picture with evidence of both rheumatoid arthritis and a seronegative disorder. Thus, the HLA-B27 allele contributed to the radiographic features in 44% of patients with rheumatoid arthritis and associated HLA-B27. Thus, the wide range of findings in our population indicates that the radiographic attributes are not specific enough to constitute a unique subpopulation of patients with rheumatoid arthritis. (orig.)

  11. Effects of barium on the nonlinear electrical characteristics and dielectric properties of SnO2-based varistors

    Institute of Scientific and Technical Information of China (English)

    Wang Chun-Ming; Wang Jin-Feng; Wang Chun-Lei; Chen Hong-Cun; Su Wen-Bin; Zang Guo-Zhong; Qi Peng; Zhao Ming-Lei; Ming Bao-Quan

    2004-01-01

    The effects of barium on electrical and dielectric properties of the SnO2·Co2Oa.Ta2O5 varistor system sintered at 1250℃ for 60min were investigated. It is found that barium significantly improves the nonlinear properties. The breakdown electrical field increases from 378.0 to 2834.5V/mm, relative dielectric constant (at 1kHz) falls from 1206 to 161 and the resistivity (at 1kHz) rises from 60.3 to 1146.5kΩ·cm with an increase of BaCO3 concentration from 0mol%to 1.00mol%. The sample with 1.00mol% barium has the best nonlinear electrical property and the highest nonlinear coefficient (α=29.2). A modified defect barrier model is introduced to illustrate the grain-boundary barrier formation of barium-doped SnO2-based varistors.

  12. A clinico-radiographic analysis of sagittal condylar guidance determined by protrusive interocclusal registration and panoramic radiographic images in humans

    OpenAIRE

    Krishna Prasad, D.; Namrata Shah; Chethan Hegde

    2012-01-01

    Purpose: To evaluate the correlation between sagittal condylar guidance obtained by protrusive interocclusal records and panoramic radiograph tracing methods in human dentulous subjects. Materials and Methods: The sagittal condylar guidance was determined in 75 dentulous subjects by protrusive interocclusal records using Aluwax through a face bow transfer (HANAU™ Spring Bow, Whip Mix Corporation, USA) to a semi-adjustable articulator (HANAU™ Wide-Vue Articulator, Whip Mix Corporation, USA). I...

  13. The anterior loop of the inferior alveolar nerve. A radiographic study of panoramic radiographs and review of the literature.

    Directory of Open Access Journals (Sweden)

    Konstantinos VLASTOS

    2014-04-01

    Full Text Available The inferior alveolar nerve sometimes extends anteriorly beyond the mental foramen and runs outward, upward and backward before it reaches the mental foramen, creating what is known as the anterior loop. Placement of dental implants in this area, has a high risk of injury to the inferior alveolar nerve. Aim: This study seeks to investigate the visualization of the anterior loop on panoramic radiographs. Material and methods: 100 panoramic radiographs were analysed in terms of loop visualization. Results: Anterior loop was observed in 34% of the radiographs. Its prevalence was higher in males (70.5% and in patients between 40-60 years old (47%. In most cases the loop was located bilaterally (64.7%, while the interforaminal area was mostly edentulous (64.7%. The loop length ranged between 0.5-8 mm, with an average length of 4.37mm. Conclusions: An analysis of the findings shows that implants should be placed at least 5-8mm anteriorly to the mental foramen. According to a review of the literature, computed tomography is more accurate than panoramic radiography in identifying the anterior loop.

  14. Use of Different Barium Salts to Inhibit the Thaumasite Form of Sulfate Attack in Cement-based Materials

    Institute of Scientific and Technical Information of China (English)

    SU Ying; WEI Xiaochao; HUANG Jian; WANG Yingbin; HE Xingyang; WANG Xiongjue; MA Baoguo

    2016-01-01

    We investigated the effects of different barium compounds on the thaumasite form of sulphate attack (TSA) resistance of cement-based materials when they were used as admixtures in mortars. Moreover, we analyzed the inhibition mechanisms within different types of barium salts, namely BaCO3 and Ba(OH)2, on the thaumasite formation. The control cement mortar and mortars with barium salts to cement and limestone weight ratios of 0.5%, 1.0%, and 1.5% were immersed in 5% (by weight) MgSO4 solution at 5℃ to mimic TSA. Appearance, mass, and compressive strength of the mortar samples were monitored and measured to assess the general degradation extent of these samples. The products of sulphate attack were further analyzed by XRD, FTIR, and SEM, respectively. Experimental results show that different degradation extent is evident in all mortars cured in MgSO4 solution. However, barium salts can greatly inhibit such degradation. Barium in hydroxide form has better effectiveness in protection against TSA than carbonate form, which may be due to their solubility difference in alkaline cement pore solution, and the presence of these barium compounds can reduce the degree of TSA by comparison with the almost completely decomposed control samples.

  15. Scaled-energy spectroscopy of a |M|=1 Rydberg barium atom in an electric field

    Institute of Scientific and Technical Information of China (English)

    Wang Lei; Quan Wei; Shen Li; Yang Hai-Feng; Shi Ting-Yun; Liu Xiao-Jun; Liu Hong-Ping; Zhan Ming-Sheng

    2009-01-01

    We observe strong energy-dependent quantum defects in the scaled-energy Stark spectra for |M|=1 Rydberg states of barium atoms at three scaled energies: ε= -2.000, ε= -2.500 and ε=-3.000. In an attempt to explain the observations, theoretical calculations of closed orbit theory based on a model potential including core effect are performed for non-hydrogenic atoms. While such a potential has been uniformly successful for alkali atoms with a single valence electron, it fails to match experimental results for barium atoms in the 6snp Rydberg states with two valence electrons. Our study points out that this discrepancy is due to the strong perturbation from the 5d8p state, which voids the simple approximation for constant quantum defects of principle quantum number n.

  16. CORRELATED STRONTIUM AND BARIUM ISOTOPIC COMPOSITIONS OF ACID-CLEANED SINGLE MAINSTREAM SILICON CARBIDES FROM MURCHISON

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Nan; Davis, Andrew M.; Dauphas, Nicolas; Pellin, Michael J. [Department of the Geophysical Sciences, The University of Chicago, Chicago, IL, 60637 (United States); Savina, Michael R. [Chicago Center for Cosmochemistry, Chicago, IL 60637 (United States); Gallino, Roberto; Bisterzo, Sara [Dipartimento di Fisica, Università di Torino, I-10125 Torino (Italy); Gyngard, Frank [Laboratory for Space Sciences, Washington University, St. Louis, MO 63130 (United States); Käppeler, Franz [Karlsruhe Institute of Technology, Institut für Kernphysik, Karlsruhe D-76021 (Germany); Cristallo, Sergio [INAF, Osservatorio Astronomico di Collurania, I-64100 Teramo (Italy); Dillmann, Iris, E-mail: lnsmile@uchicago.edu [TRIUMF, 4004 Wesbrook Mall, Vancouver BC V6T 2A3 (Canada)

    2015-04-10

    We present strontium, barium, carbon, and silicon isotopic compositions of 61 acid-cleaned presolar SiC grains from Murchison. Comparison with previous data shows that acid washing is highly effective in removing both strontium and barium contamination. For the first time, by using correlated {sup 88}Sr/{sup 86}Sr and {sup 138}Ba/{sup 136}Ba ratios in mainstream SiC grains, we are able to resolve the effect of {sup 13}C concentration from that of {sup 13}C-pocket mass on s-process nucleosynthesis, which points toward the existence of large {sup 13}C pockets with low {sup 13}C concentrations in asymptotic giant branch stars. The presence of such large {sup 13}C pockets with a variety of relatively low {sup 13}C concentrations seems to require multiple mixing processes in parent asymptotic giant branch stars of mainstream SiC grains.

  17. Synthesis and Fluorescence of Europium-Doped Barium Fluoride Cubic Nanocolumns

    Institute of Scientific and Technical Information of China (English)

    连洪州; 刘洁; 叶泽人; 石春山

    2004-01-01

    Europium-doped barium fluoride cubic nanocolumns were synthesized from the quaternary water in oil reverse microemulsions. In this process, the aqueous cores of water/cetyl trimethyl ammonium bromide(CTAB)/n-butanol/n-octane reverse microemulsions were used as microreactors for the precipitation of europium doped barium fluoride. XRD analysis shows that under the dopant concentration of 0.06%(molar fraction), the products are single phase. The result products are cubic column-like with about 30~50 nm edge length of cross section, and about 200 nm of length obtained from the transmission electron microscopy(TEM), and atomic force microscopy(AFM). Under the 0.06%(molar fraction) of dopant concentration, the fluorescence of Eu2+ and Eu3+ under the 589 of excitation wavelength is observed.

  18. Barium phosphate conversion coating on die-cast AZ91D magnesium alloy

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Poor corrosion resistance limits the application of magnesium alloys.Conversion coating is widely used to protect magnesium alloys because of easy operation and low cost.A novel conversion coating on die.cast AZ91D magnesium alloy containing barium salts was studied.The optimum concentrations of Ba(NO3)2,Mn(NO3)2 and NH4H2PO4 are 25 g/L,15 mL/L and 20 g/L,respectively,based on orthogonal test resulm.The treating time,solution temperature and PH value are settled to be 5-30 min,50-70℃and 2.35-3.0.respectively.The corrosion resistance of barium conversion coating is better than that of manganese-based phosphate conversion coating by immersion test.The coating is composed of Ba,P, O,Mg,Zn,Mn and Al by EDX analysis.

  19. Study on the preparation and formation mechanism of barium sulphate nanoparticles modified by different organic acids

    Indian Academy of Sciences (India)

    Yuhua Shen; Chuanhao Li; Xuemei Zhu; Anjian Xie; Lingguang Qiu; Jinmiao Zhu

    2007-07-01

    This paper reports a simple method to prepare barium sulphate nanoparticles by use of tetradecanoic acid, hexadecanoic acid and stearic acid as modifier. The barium sulphate nanoparticles obtained are characterized by using Fourier transform infra-red spectroscopy (FT-IR), powder X-ray diffraction (XRD), transmission electron microscopy (TEM), dynamic laser light scatter (DLLS) and thermogravimetric analysis (TGA), respectively. The results show that the BaSO4 particles are all spherical and in the nano-scale. Our method has a better dispersion and controllable diameter dependent on the length of the chain of organic acid and the pH value of the system. A possible mechanism is also discussed.

  20. Efficient photoionization for barium ion trapping using a dipole-allowed resonant two-photon transition

    CERN Document Server

    Leschhorn, G; Schaetz, T

    2011-01-01

    Two efficient and isotope-selective resonant two-photon ionization techniques for loading barium ions into radio-frequency (RF)-traps are demonstrated. The scheme of using a strong dipole-allowed transition at \\lambda=553 nm as a first step towards ionization is compared to the established technique of using a weak intercombination line (\\lambda=413 nm). An increase of two orders of magnitude in the ionization efficiency is found favoring the transition at 553 nm. This technique can be implemented using commercial all-solid-state laser systems and is expected to be advantageous compared to other narrowband photoionization schemes of barium in cases where highest efficiency and isotope-selectivity are required.

  1. Barium hexaferrite/graphene oxide: controlled synthesis and characterization and investigation of its magnetic properties

    Science.gov (United States)

    Maddahfar, Mahnaz; Ramezani, Majid; Mostafa Hosseinpour-Mashkani, S.

    2016-08-01

    In the present study, barium hexaferrite nanocrystals (BaFe12O19) were successfully synthesized through the two-step sol-gel method in an aqueous solution in the presence of barium nitrate and iron (III) nitrate. Besides, the effect of the molar ratio of graphene oxide on the particle size and magnetic properties of final product was investigated. In this research, glucose plays a role as capping and chelating agent in the synthesis of BaFe12O19/graphene oxide. Moreover, it was found that the size, morphology, and magnetic properties of the final products could be greatly influenced by the molar ratio of graphene oxide. BaFe12O19/graphene oxide was characterized by using X-ray diffraction, scanning electron microscope, Fourier transform infrared spectroscopy, vibrating sample magnetometer, and energy-dispersive spectrometry.

  2. Correlated Strontium and Barium Isotopic Compositions of Acid-Cleaned Single Silicon Carbides from Murchison

    CERN Document Server

    Liu, Nan; Gallino, Roberto; Davis, Andrew M; Bisterzo, Sara; Gyngard, Frank; Kaeppeler, Franz; Cristallo, Sergio; Dauphas, Nicolas; Pellin, Michael J; Dillmann, Iris

    2015-01-01

    We present strontium, barium, carbon, and silicon isotopic compositions of 61 acid-cleaned presolar SiC grains from Murchison. Comparison with previous data shows that acid washing is highly effective in removing both strontium and barium contamination. For the first time, by using correlated $^{88}Sr$/$^{86}Sr$ and $^{138}Ba$/$^{136}Ba$ ratios in mainstream SiC grains, we are able to resolve the effect of $^{13}C$ concentration from that of $^{13}C$-pocket mass on s-process nucleosynthesis, which points towards the existence of large $^{13}C$-pockets with low $^{13}C$ concentration in AGB stars. The presence of such large $^{13}$R-pockets with a variety of relatively low $^{13}C$ concentrations seems to require multiple mixing processes in parent AGB stars of mainstream SiC grains.

  3. Absolute Te$_2$ reference for barium ion at $455.4~$nm

    CERN Document Server

    Dutta, T; Mukherjee, M

    2016-01-01

    Precision atomic spectroscopy is presently the work horse in quantum information technology, metrology, trace analysis and even for fundamental tests in physics. Stable lasers are inherent part of precision spectroscopy which in turn requires absolute wavelength markers suitably placed corresponding to the atomic species being probed. Here we present, new lines of tellurium (Te$_2$) which allows locking of external cavity diode laser (ECDL) for precision spectroscopy of singly charged barium ions. In addition, we have developed an ECDL with over 100 GHz mod-hop-free tuning range using commercially available diode from $\\textit{Nichia}$. These two developments allow nearly drift-free operation of a barium ion trap set-up with one single reference cell thereby reducing the complexity of the experiment.

  4. Gamma-ray shielding and structural properties of barium-bismuth-borosilicate glasses

    Science.gov (United States)

    Bootjomchai, Cherdsak; Laopaiboon, Jintana; Yenchai, Chadet; Laopaiboon, Raewat

    2012-07-01

    The attenuation coefficients of barium-bismuth-borosilicate glasses have been measured for gamma-ray photon energies of 662, 1173 and 1332 keV using a narrow beam transmission geometry. These coefficients were then used to obtain the values of mass attenuation coefficients, effective atomic number, effective electron density and mean free path. Good agreement has been observed between experimental and theoretical values of these parameters. From the obtained results it is reported here that from the barium-bismuth-borosilicate glasses are better shields to gamma-radiations in comparison to the standard radiation shielding concretes from the shielding point of view. The molar volume, FTIR and acoustic investigations have been used to study the structural properties of the prepared glass system. The obtained results reveal that the formation of non-bridging oxygens occurs at higher concentration of Bi2O3.

  5. Comparison between sodium hypochlorite and copper sulfate reducer in lightening of overexposed working length radiographs

    Directory of Open Access Journals (Sweden)

    Fatemeh Ezoddini Ardakani

    2015-12-01

    Full Text Available Objectives: The aims of this study were to test whether lightening of the overexposed radiographs improve determination of endodontic files length and whether lightened radiographs are comparable with ideally exposed radiographs. Material and Methods: Four dried human skull coated with soft tissue-equivalent wax used for exposing radiographs of the upper molars. First, the endodontic file was placed in full length of the root and four series of radiographs obtained. The time to expose the first series was unchanged (standard group but increased for the other three series.  Two series of overexposed radiographs set as test groups (one lightened with copper sulfate reducer and the other lightened with sodium hypochlorite and one series set as control group. Then the endodontic file placed 2mm short in the root and four series of radiographs obtained like the former. A viewer evaluated radiographs. ROC curves were obtained and areas under the curves were calculated. Sensitivity, specificity and Cohen’s kappa was calculated. Results: The average area under ROC curves was 1, 0.995,1 and 0.643 for the standard, Copper sulfate, sodium hypochlorite and the control group, respectively. Sodium hypochlorite show a better performance in terms of sensitivity and specificity compared to Copper sulfate. Differences between the test radiographs and standard and control radiographs were significant (p

  6. Variability amongst radiographers in the categorization of clinical acceptability for digital trauma radiography

    Science.gov (United States)

    Decoster, Robin; Toomey, Rachel; Smits, Dirk; Mol, Harrie; Verhelle, Filip; Butler, Marie-Louise

    2016-03-01

    Introduction: Radiographers evaluate anatomical structures to judge clinical acceptability of a radiograph. Whether a radiograph is deemed acceptable for diagnosis or not depends on the individual decision of the radiographer. Individual decisions cause variation in the accepted image quality. To minimise these variations definitions of acceptability, such as in RadLex, were developed. On which criteria radiographers attribute a RadLex categories to radiographs is unknown. Insight into these criteria helps to further optimise definitions and reduce variability in acceptance between radiographers. Therefore, this work aims the evaluation of the correlation between the RadLex classification and the evaluation of anatomical structures, using a Visual Grading Analysis (VGA) Methods: Four radiographers evaluated the visibility of five anatomical structures of 25 lateral cervical spine radiographs on a secondary class display with a VGA. They judged clinical acceptability of each radiograph using RadLex. Relations between VGAS and RadLex category were analysed with Kendall's Tau correlation and Nagelkerke pseudo-R². Results: The overall VGA score (VGAS) and the RadLex score correlate (rτ= 0.62, pConclusion: RadLex scores and VGAS correlate positively, strongly and significantly. The predictive value of bony structures may support the use of these in the judgement of clinical acceptability. Considerable inter-observer variations in the VGAS within a certain RadLex category, suggest that observers use of observer specific cut-off values.

  7. A comparison of digitally scanned radiographs with conventional film for the detection of small endodontic instruments.

    Science.gov (United States)

    Fuge, K N; Stuck, A M; Love, R M

    1998-03-01

    The use of computers in dentistry is becoming common as a practice tool for a diverse number of tasks, including the storage and enhancement of intra-oral radiographs. Several systems of digital radiography are available to produce a digital image including irradiation of a charged-couple device and scanning conventional radiographs. This study compared various digital images of scanned periapical radiographs with the original radiographs to determine whether the digitized images offered any advantage when viewing small files at the radiographic apex. Twenty extracted permanent molar teeth were prepared by gaining straight line access to the root canals and a ISO size 06 K-file was introduced into one of the canals until the tip was flush with the apical foramen. Using a standardized technique, radiographs were taken of the teeth using E-speed film. The radiographs were scanned and five digital images: original, enhanced, negative to positive conversion, zoom and zoom of negative to positive were produced. Three evaluators compared each of the images with the radiograph for clarity of the endodontic file in relation to the radiographic apex. Results were analysed using the Wilcoxon signed rank test and the Kappa (kappa) test was used to measure the level of agreement between the three evaluators. The results revealed that all the digital images produced by this scanner were inferior to the radiograph (P < 0.001) and that there was high agreement between evaluators.

  8. Kinetics of barium sulphate reaction crystallization in crystallizers with internal circulation

    Directory of Open Access Journals (Sweden)

    J. Koralewska

    2008-06-01

    Full Text Available Kinetic calculation results describing the observed nucleation and growth rates of barium sulphate crystals precipitated in an integrated reaction-crystallization process in a barium sulphate-ammonium chloride-water system are presented and analyzed. The scope of experiments included two continuous model DTM-type crystallizers (Draft Tube Magma with internal circulation of the suspension forced by a liquid jet-pump device responsible for stable and intensive enough ascending/descending flow of BaSO4 crystal magma in a mixing chamber. For comparison purposes the experimental data corresponding to a continuous DT (Draft Tube crystallizer with propeller agitator are presented and discussed. The various types of laboratory crystallizers used were fed with concentrated water solution of barium chloride (of 10 or 24 mass % and - in a stoichiometric proportion - crystalline ammonium sulphate, assuming isothermal (348 K and hydrodynamic (average residence time of suspension in a crystallizer: 900 s process conditions. The observed nucleation and growth rates of barium sulphate crystals were estimated on the basis of crystal size distributions (CSDs using convenient calculation scheme derived for an MSMPR (Mixed Suspension Mixed Product Removal model approach. Considering the experimental population density distribution courses, a size-dependent growth (SDG phenomenon was taken into account in the kinetic calculations. Five SDG kinetic models recommended in the accessible literature were used for kinetic parameter values estimation. It was proved statistically, that Rojkowski’s two SDG models (hyperbolic and exponential best suit for our own experimental data description. The experimental data presented can be practically applied for improving the constructions of liquid jet-pump DTM crystallizers recommended for reaction crystallization of sparingly soluble inorganic salts (especially for high concentrations of reaction substrates in the modern

  9. Establishment of a protocol for determining gastrointestinal transit time in mice using barium and radiopaque markers

    Energy Technology Data Exchange (ETDEWEB)

    Myagmarjaibuu, Bilomaa; Moon, Myeong Ju; Heo, Suk Hee; Jeong, Seo In; Jeong, Yong Yeon; Kang, Heoung Keun [Dept. of Radiology, Chonnam National University Hwasun Hospital, Chonnam National University Medical School, Hwasun (Korea, Republic of); Park, Jong Seong [Dept. of Physiology, Chonnam National University Medical School, Gwangju (Korea, Republic of); Jun, Jae Yeoul [Dept. of Physiology, College of Medicine, Chosun University, Gwangju (Korea, Republic of)

    2013-01-15

    The purpose of this study was to establish a minimally invasive and reproducible protocol for estimating the gastrointestinal (GI) transit time in mice using barium and radiopaque markers. Twenty 5- to 6-week-old Balb/C female mice weighing 19-21 g were used. The animals were divided into three groups: two groups that received loperamide and a control group. The control group (n = 10) animals were administered physiological saline (1.5 mL/kg) orally. The loperamide group I (n = 10) and group II (n = 10) animals were administered 5 mg/kg and 10 mg/kg loperamide orally, respectively. Thirty minutes after receiving the saline or loperamide, the mice was administered 80 μL of barium solution and six iron balls (0.5 mm) via the mouth and the upper esophagus by gavage, respectively. Afterwards, the mice were continuously monitored with fluoroscopic imaging in order to evaluate the swallowing of the barium solution and markers. Serial fluoroscopic images were obtained at 5- or 10-min intervals until all markers had been excreted from the anal canal. For analysis, the GI transit times were subdivided into intestinal transit times (ITTs) and colon transit times (CTTs). The mean ITT was significantly longer in the loperamide groups than in the control group (p < 0.05). The mean ITT in loperamide group II (174.5 ± 32.3) was significantly longer than in loperamide group I (133.2 ± 24.2 minute) (p < 0.05). The mean CTT was significantly longer in loperamide group II than in the control group (p < 0.05). Also, no animal succumbed to death after the experimental procedure. The protocol for our study using radiopaque markers and barium is reproducible and minimally invasive in determining the GI transit time of the mouse model.

  10. Wideband electromagnetic wave absorber using doped barium hexaferrite in Ku-band

    Energy Technology Data Exchange (ETDEWEB)

    Tehrani, Masoud Kavosh, E-mail: m_kavosh@mut-es.ac.ir [Department of Physics, Malek-ashtar University of Technology, Shahin Shahr (Iran, Islamic Republic of); Ghasemi, Ali [Department of Material Engineering, Malek-ashtar University of Technology, Shahin Shahr (Iran, Islamic Republic of); Moradi, Mahmood; Alam, Reza Shams [Department of Physics, Shiraz University, Shiraz (Iran, Islamic Republic of)

    2011-08-18

    Highlights: > Substituted barium hexaferrite BaMg{sub 0.25}Mn{sub 0.25}Co{sub 0.5}Ti{sub 1.0}Fe{sub 10}O{sub 19} was prepared in powder configuration by solid state reaction. > The results exhibit a wideband single-layer microwave absorber with a satisfactory reflection loss throughout Ku-band. > The composite specimens for measurement of microwave absorber properties were prepared by mixing doped barium ferrite and PVC with a concentration of 70:30 by weight. > The bandwidth that can be achieved by utilization of this sample is 4.5 GHz. Minimum reflection loss of -34 dB can be obtained by sample '(e)'. - Abstract: Substituted barium hexaferrite BaMg{sub 0.25}Mn{sub 0.25}Co{sub 0.5}Ti{sub 1.0}Fe{sub 10}O{sub 19} was prepared in powder configuration by solid state reaction. The ferrite powders were mixed with polyvinylcloride (PVC) plasticizer to fabricate a microwave absorbing composite. X-ray diffraction (XRD), scanning electron microscope (SEM), vibrating sample magnetometer (VSM), and vector network analyzer were employed to characterize phase identification coupled with size and morphology of powder and microwave absorption properties of synthesized composites. It was found that the maximum reflection loss of -40 dB was appeared at frequency range of 12-18 GHz. In the present work, new cation substitutions in iron sites in the crystal lattice of barium ferrite, which can easily tune the bandwidth of the reflection loss, were used. To the best of our knowledge, this is the first study which displays the wideband absorber by employing single layer hexaferrite backed on the surface of copper.

  11. Electrical properties of thick film capacitors based on barium titanate glass formulations

    Energy Technology Data Exchange (ETDEWEB)

    Leppaevuori, S.; Uusimaeki, A.; Hannula, T.

    1981-12-18

    We carried out an investigation of the effects of the glass content of the dielectric layer of thick film capacitors with a barium titanate glass formulation on the capacitance density, loss factor and breakdown voltage of the capacitors. These effects were studied by varying the firing temperature and glass content of the dielectric paste and by using different types of electrode paste. The characteristics of a test capacitor were also measured.

  12. Effect of boric acid sintering aid on densification of barium ferrite

    Indian Academy of Sciences (India)

    S S Vidyawathi; R Amaresh; L N Satapathy

    2002-11-01

    Boric acid has been added in 0.1–0.6% range for studying the densification characteristics of solid state sintered barium hexaferrite. Sintering studies have been carried out at three different temperatures. Physical properties like density and porosity have been studied for all compositions. The phase identification and microstructural investigation on the fractured surface have been carried out to understand the effect of sintering aid on the densification characteristics.

  13. Nanoparticles for cultural heritage conservation: calcium and barium hydroxide nanoparticles for wall painting consolidation.

    Science.gov (United States)

    Giorgi, Rodorico; Ambrosi, Moira; Toccafondi, Nicola; Baglioni, Piero

    2010-08-16

    Nanotechnology provides new concepts and materials for the consolidation and protection of wall paintings. In particular, humble calcium and barium hydroxide nanoparticles offer a versatile and highly efficient tool to combat the main degradation processes altering wall paintings. Clear example of the efficacy and potentiality of nanotechnology is represented by the conservation in situ of Maya wall paintings in the archaeological area in Calakmul (Mexico).

  14. Phase conjugation, isotropic and anisotropic higher order diffraction generation, and image correlation using photorefractive barium titanate

    Science.gov (United States)

    Buranasiri, Prathan

    2005-04-01

    Using barium titanate as the photorefractive material, we demonstrate phase conjugation, beam coupling, higher diffraction order generation. At small incident angles less than 0.015 radian, both codirectional isotropic self-diffraction (CODIS) and contradirectional isotropic self-diffraction (CONDIS) are generated simultaneously. At bigger incident angles approximately more than 0.2094 radian, only codirectional anisotropic-self diffraction (CODAS) are generated. On going imaging correlation is also showing.

  15. Neutron beam test of barium fluoride crystal for dark matter direct detection

    Science.gov (United States)

    Guo, C.; Ma, X. H.; Wang, Z. M.; Bao, J.; Dai, C. J.; Guan, M. Y.; Liu, J. C.; Li, Z. H.; Ren, J.; Ruan, X. C.; Yang, C. G.; Yu, Z. Y.; Zhong, W. L.

    2016-10-01

    In order to test the capabilities of Barium Fluoride (BaF2) crystal for dark matter direct detection, nuclear recoils are studied with mono-energetic neutron beam. The energy spectra of nuclear recoils, quenching factors for elastic scattering neutrons and discrimination capability between neutron inelastic scattering events and γ events are obtained for various recoil energies of the F content in BaF2.

  16. Growth and study of barium oxalate single crystals in agar gel

    Indian Academy of Sciences (India)

    P V Dalal; K B Saraf

    2006-10-01

    Barium oxalate was grown in agar gel at ambient temperature. The effect of various parameters like gel concentration, gel setting time and concentration of the reactants on the growth of these crystals was studied. Prismatic platy shaped spherulites and dendrites were obtained. The grown crystals were characterized by X-ray powder diffractometry, infrared spectroscopy, thermogravimetric and differential thermal analysis. An attempt is made to explain the spherulitic growth mechanism.

  17. A System for Trapping Barium Ions in a Microfabricated Surface Trap

    CERN Document Server

    Graham, Richard D; Sakrejda, Tomasz; Wright, John; Zhou, Zichao; Blinov, Boris B

    2013-01-01

    We have developed a vacuum chamber and control system for rapid testing of microfabricated surface ion traps. Our system uses a modular design and is based on an in-vacuum PCB with integrated filters. We have used this system to successfully trap and cool barium ions. We have demonstrated ion 'dark' lifetimes of 31.6 s +- 3.4 s and controlled shuttling of ions using a custom 96 electrode control system with an update rate of 40 kHz.

  18. Absolute Te$_2$ reference for barium ion at $455.4~$nm

    OpenAIRE

    Dutta, T; Munshi, D; Mukherjee, M.(Variable Energy Cyclotron Centre, Kolkata, India)

    2016-01-01

    Precision atomic spectroscopy is presently the work horse in quantum information technology, metrology, trace analysis and even for fundamental tests in physics. Stable lasers are inherent part of precision spectroscopy which in turn requires absolute wavelength markers suitably placed corresponding to the atomic species being probed. Here we present, new lines of tellurium (Te$_2$) which allows locking of external cavity diode laser (ECDL) for precision spectroscopy of singly charged barium ...

  19. Modification of gray iron produced by induction melting with barium strontium

    Science.gov (United States)

    Modzelevskaya, G.; Feoktistov, A. V.; Selyanin, I. F.; Kutsenko, A. I.; Kutsenko, A. A.

    2016-09-01

    The article provides analysis of results of gray iron experimental melts in induction furnace and the following melt modification with barium-strontium carbonate (BSC-2). It is shown that modification positively affects mechanical and casting properties and as-cast iron structure. It was established that BSC-2 granulated immediately prior to use has greater impact on melt than BSC-2 of the same faction, supplied by the manufacturer.

  20. Análise anátomo-radiográfica da persistência do Forame de Huschke Anatomic and radiograph study of the persistence of Foramen of Huschke

    Directory of Open Access Journals (Sweden)

    Rodrigo Costa Moreno

    2005-10-01

    Full Text Available OBJETIVO: o objetivo neste trabalho é avaliar e localizar o Forame de Huschke. FORMA DE ESTUDO: anatômico. MATERIAL E MÉTODO: utilizando materiais de contraste como a Guta percha e o sulfato de bário, através de técnicas radiográficas extrabucais, como a panorâmica, submentovértex e a tomografia linear lateral corrigida para a Articulação Têmporo-mandibular, em quatro crânios, onde foi verificada clinicamente a presença do Forame de Huschke. RESULTADO: Os resultados obtidos mostraram que o Forame de Huschke pôde ser observado em crânios secos após a sua evidenciação por meio de material de contraste nestas técnicas radiográficas.AIM: the aim of this study is to assess and locate the Foramen of Huschke. STUDY DESIGN: anatomical. MATERIAL AND METHOD: using contrast material like gutta-percha and barium sulfate, through extraoral radiographs, such as panoramic, submental vertex and corrected saggital linear Temporal Mandibular Joint tomograms in four skulls where we clinically checked the existence of foramen of Huschke. RESULTS: The results proved that the foramen of Huschke can be observed in skulls submitted to contrast using radiographic techniques.

  1. Luminescence of Er3+ Doped Titanium Barium Glass Microsphere under 514 nm Excitation

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The titanium barium glass microspheres doped with Er2O3 were designed and prepared. The components of the glass sample were 25TiO2-27BaCO3-8Ba(NO3)2-5ZnO2-10CaCO3-5H3BO3-10SiO2-7water glass-3Er2O3 (%, mass fraction). The emission spectra of titanium barium glass matrix and the titanium barium glass microsphere under 514 nm excitation were measured with micro-Raman spectrometer. Whispering gallery modes in the emission spectra from a 31 μm glass microsphere were observed. Many regularly spaced, sharp peaks appeared in the emission spectra of the Er2O3-doped glass microsphere. The wavelength separation between the two adjacent peaks is 1.92 nm for the 31 μm microsphere. According to the Lorenz-Mie formula, the calculated value of the wavelength separation between the two adjacent peaks is 1.95 nm. The observed resonances could be assigned by using the well-known Lorenz-Mie formula.

  2. An effective quantum defect theory for the diamagnetic spectrum of a barium Rydberg atom

    Institute of Scientific and Technical Information of China (English)

    Li Bo; Liu Hong-Ping

    2013-01-01

    A theoretical calculation is carried out to investigate the spectrum of a barium Rydberg atom in an external magnetic field.Using an effective approach incorporating quantum defect into the centrifugal term in the Hamiltonian,we reexamine the reported spectrum of the barium Rydberg atom in a magnetic field of 2.89 T [J.Phys.B 28 L537 (1995)].Our calculation employs B-spline basis expansion and complex coordinate rotation techniques.For single photon absorption from the ground 6s2 to 6snp Rydberg states,the spectrum is not influenced by quantum defects of channels ns and nd.The calculation is in agreement with the experimental observations until the energy reaches E =-60 cm-1.Beyond this energy,closer to the threshold,the calculated and experimental results do not agree with each other.Possible reasons for their discrepancies are discussed.Our study affirms an energy range where the diamagnetic spectrum of the barium atom can be explained thoroughly using a hydrogen model potential.

  3. Single molecule fluorescence imaging as a technique for barium tagging in neutrinoless double beta decay

    Science.gov (United States)

    Jones, B. J. P.; McDonald, A. D.; Nygren, D. R.

    2016-12-01

    Background rejection is key to success for future neutrinoless double beta decay experiments. To achieve sensitivity to effective Majorana lifetimes of ~ 1028 years, backgrounds must be controlled to better than 0.1 count per ton per year, beyond the reach of any present technology. In this paper we propose a new method to identify the birth of the barium daughter ion in the neutrinoless double beta decay of 136Xe. The method adapts Single Molecule Fluorescent Imaging, a technique from biochemistry research with demonstrated single ion sensitivity. We explore possible SMFI dyes suitable for the problem of barium ion detection in high pressure xenon gas, and develop a fiber-coupled sensing system with which we can detect the presence of bulk Ba++ ions remotely. We show that our sensor produces signal-to-background ratios as high as 85 in response to Ba++ ions when operated in aqueous solution. We then describe the next stage of this R&D program, which will be to demonstrate chelation and fluorescence in xenon gas. If a successful barium ion tag can be developed using SMFI adapted for high pressure xenon gas detectors, the first essentially zero background, ton-scale neutrinoless double beta decay technology could be realized.

  4. Optical planar waveguide in sodium-doped calcium barium niobate crystals by carbon ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jin-Hua, E-mail: zhaojinhuazjh@gmail.com [School of Science, Shandong Jianzhu University, Jinan 250101 (China); Qin, Xi-Feng; Wang, Feng-Xiang; Fu, Gang; Wang, Hui-Lin [School of Science, Shandong Jianzhu University, Jinan 250101 (China); Wang, Xue-Lin [School of Physics, Key Laboratory of Particle Physics and Particle Irradiation, Ministry of Education, and State Key Laboratory of Crystal Materials, Shandong University, Jinan 250100 (China)

    2013-07-15

    There is great interest in niobate crystals which belong to the tetragonal tungsten bronze (TTB) families owing to their intriguing properties. As one representative of such crystals, CBN (calcium barium niobate) has attracted rapidly growing attention. Because it has a higher Curie temperature than SBN (strontium barium niobate), possesses outstanding ferroelectric and it possesses optical properties. In addition, doped with sodium, CBN will show a higher Curie temperature than pure CBN. We report on the fabrication and characterization of optical planar waveguide in x-cut sodium-doped calcium barium niobate crystal by using C ion implantation. The guided-mode properties at the wavelength of 633 and 1539 nm are investigated through prism-coupling measurements, respectively. By applying direct end-face coupling arrangement, the near-field optical intensity distribution of waveguide modes is measured at 633 nm. For comparison, the modal profile of the same guided mode is also numerically calculated by the finite difference beam-propagation method via computer software BeamPROP. The transmission spectra of the waveguide before and after ion implantation treatments were investigated also. Our experiment results reveal that the waveguide could propagate light with transverse magnetic polarized direction only and it is assumed that the polarization selectivity of CBN crystal may responsible for this phenomenon.

  5. Factors influencing the detection of abnormalities in barium enemas performed by junior radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Vehmas, T. [Department of Occupational Medicine, Finnish Institute of Occupational Health, Helsinki and Department of Radiology, Helsinki University Central Hospital, Helsinki (Finland)]. E-mail: tapio.vehmas@ttl.fi

    2006-03-15

    Aim: To study the effects of patient variability, technical examination and radiologist-related factors on the radiological diagnosis of barium enema studies. Materials and Methods: Twenty-one residents (12 women and nine men, age 26-39 years) performed 523 double contrast barium enemas in a university hospital. Diagnoses were classified as normal (n=203), diverticulosis (n=224), polyps (n=25), tumours (n=20) and other (n=46); five were missing diagnoses. Binary and multinomial logistic regressions were used to study the relations between the independent variables and the radiological diagnoses. Results: Patients' advanced age (p<0.001) and obesity (p=0.041) were significant positive predictors for the detection of any abnormalities, as was good or moderate study quality (p=0.023). However, patients' obesity was negatively associated with the detection of polyps (p=0.037). Pathological findings were associated with higher dose-area products (p=0.047) than normal cases. Residents' advanced age (p=0.029) and experience (a high number of previously performed barium enemas; p=0.009) were negative predictors for the detection of pathological findings. Conclusion: Patients' obesity hampers polyp detection, possibly due to decreased image quality or coexisting diverticula. The most experienced and oldest residents missed positive findings, possibly due to insufficient consultation of supervising radiologists, emphasizing the need for their optimal cooperation.

  6. A Preliminary Trial on the Use of Barium Chloride for Pregnancy Diagnosis in Sows

    Directory of Open Access Journals (Sweden)

    Ndu, A.

    2000-01-01

    Full Text Available Urine was collected twice daily (once in the morning and once in the afternoon for 5 days from 80 Yorkshire x Landrace crossbred gilts/sows made up of 40 non-pregnant and 40 pregnant pigs in an investigation to determine the possibility of using 1 % barium chloride solution for pregnancy diagnosis in pigs based on a previous report that addition of a few drops of 1 % barium chloride solution to bovine urine caused a white precipitate with non-pregnant but not with pregnant cows. The pregnant pigs were in various stages of gestation. Urine reaction to 1 % barium chloride was highly (P <0.01 dependent on the pregnancy status of the sows, the test being 100 % and 81 % effective in identifying non-pregnant and pregnant sows respectively. The sensitivity of the test in the gravid sows was significantly (P <0.05 influenced by and tended to increa-se with the stage of gestation, with 59 % of the sows in their first stage of gestation (<38 days post-coitum being correctly diagnosed as pregnant, and 95-100 % of those in their latter stages of gestation being so correctly diagnosed. Parity and time of day of performance of the test had no effect on urine reaction. It was concluded that the test was at least 95 % accurate when used as from about 39 days after breeding for pregnancy diagnosis in sows.

  7. Effects of Dysprosium Oxide Doping on Microstructure and Properties of Barium Titanate Ceramic

    Institute of Scientific and Technical Information of China (English)

    Pu Yongping; Ren Huijun; Chen Wei; Chen Shoutian

    2005-01-01

    Different amounts of dysprosium oxide were incorporated into barium titanate powders synthesized by hydrothermal method. Relations of substitution behaviors and lattice parameters with solid-solubility were studied. Furthermore, the influences of dysprosium oxide doping fraction on grain size and dielectric properties of barium titanate ceramic, including dielectric constant and breakdown electric field strength, were investigated via scanning electron microscope, X-ray diffraction and electric property tester. The results show that dysprosium oxide can restrain abnormal grain growth during sintering and that fine-grained and high density of barium titanate ceramic can result in excellent dielectric properties. As mass fraction of dysprosium oxide is 0.6%, the lattice parameters of grain increase to the maximum because of the lowest vacancy concentration. The electric property parameters are cited as following: dielectric constant (25 ℃) reaches 4100, the change in relative dielectric constant with temperature is -10% to 10% within the range of -15~100 ℃, breakdown electric field strength (alternating current) achieves 3.2 kV·mm-1, which can be used in manufacturing high voltage ceramic capacitors.

  8. Hydrothermal Synthesis and Characterization of Europium-dop ed Barium Titanate Nano crys-tallites

    Institute of Scientific and Technical Information of China (English)

    Margarita Garca-Hernandez; Genevieve Chadeyron; Damien Boyer; Antonieta Garca-Murillo; Felipe Carrillo-Romo; Rachid Mahiou

    2013-01-01

    Barium titanate nanocrystallites were synthesized by a hydrothermal technique from barium chlo-ride and tetrabutyl titanate. Single-crystalline cubic perovskite BaTiO3 consisting of spherical particles with diameters ranging from 10 to 30 nm was easily achieved by this route. In order to study the influence of the syn-thesis process on the morphology and the optical properties, barium titanate was also prepared by a solid-state reaction. In this case, only the tetragonal phase which crystallizes above 900℃ was observed. High-temperature X-ray diffraction measurements were performed to investigate the crystallization temperatures as well as the particle sizes via the Scherrer formula. The lattice vibrations were evidenced by infrared spectroscopy. Eu3+was used as a structural probe, and the luminescence properties recorded from BaTiO3:Eu3+and elaborated by a solid-state reaction and hydrothermal process were compared. The reddish emission of the europium is increased by the nanometric particles.

  9. Barium Surface Abundances of Blue Stragglers in the Open Cluster NGC 6819

    CERN Document Server

    Milliman, Katelyn E; Schuler, Simon C

    2015-01-01

    We present the barium surface abundance of 12 blue stragglers (BSs) and 18 main-sequence (MS) stars in the intermediate-age open cluster NGC 6819 (2.5 Gyr) based on spectra obtained from the Hydra Multi-object Spectrograph on the WIYN 3.5 m telescope. For the MS stars we find [Fe/H] = $+$0.05 $\\pm$ 0.04 and [Ba/Fe] = $-$0.01 $\\pm$ 0.10. The majority of the BS stars are consistent with these values. We identify five BSs with significant barium enhancement. These stars most likely formed through mass transfer from an asymptotic giant branch star that polluted the surface of the BS with the nucleosynthesis products generated during thermal pulsations. This conclusion aligns with the results from the substantial work done on the BSs in old open cluster NGC 188 that identifies mass transfer as the dominant mechanism for BS formation in that open cluster. However, four of the BSs with enhanced barium show no radial-velocity evidence for a companion. The one star that is in a binary is a double-lined system, meaning...

  10. A barium central star binary in the Type-I diamond ring planetary nebula Abell 70

    CERN Document Server

    Miszalski, B; Frew, D J; Acker, A; Köppen, J; Moffat, A F J; Parker, Q A

    2011-01-01

    Abell 70 (PN G038.1-25.4, hereafter A 70) is a planetary nebula (PN) known for its diamond ring appearance due a superposition with a background galaxy. The previously unstudied central star is found to be a binary consisting of a G8IV-V secondary at optical wavelengths and a hot white dwarf (WD) at UV wavelengths. The secondary shows Ba II and Sr II features enhanced for its spectral type that, combined with the chromospheric Halpha emission and possible 20-30 km/s radial velocity amplitude, firmly classifies the binary as a Barium star. The proposed origin of Barium stars is intimately linked to PNe whereby wind accretion pollutes the companion with dredged-up material rich in carbon and s-process elements when the primary is experiencing thermal pulses on the Asymptotic Giant Branch (AGB). A 70 provides further evidence for this scenario together with the other very few examples of Barium central stars. The nebula is found to have Type-I chemical abundances with helium and nitrogen enrichment, which when c...

  11. Er3+-substituted W-type barium ferrite: preparation and electromagnetic properties

    Institute of Scientific and Technical Information of China (English)

    HUANG

    2010-01-01

    Er3+-substituted W-type barium ferrites Ba1-xErx(Zn0.3Co0.7)2Fe16O27(x=0.00,0.05,0.10,0.15,0.20)were synthesized by polymer adsorbent combustion method.Samples were characterized by X-ray diffraction analysis(XRD),X-ray fluorescence(XRF),scanning electron microscopy(SEM)and network analyzer to investigate the relationships among Er3+concentration,crystal structure,surface mcrphology and electromagnetic properties.All the XRD patterns showed pure phase of W-type barium ferrite when x≤0.15,while the impurity phase of ErFeO3 appeared when x=0.20.The pure W-type barium ferrite showed a hexagonal flake shape.In addition,the microwave electromagnetic properties of samples were analyzed in the frequency range of 2-18 GHz.It was indicated that the electromagnetic properties were significantly improved when Er3+doping content was 0.10.The reasons were also discussed using electromagnetic theory.The optimized ferrite exhibited excellent microwave absoption performance.The maximum of reflection loss(RL)reached about-27.4 dB and RL was below-10dB at the frequency range from 8.4 GHz to 18 GHz,when the thickness was 2.6 mm.

  12. Bronchopulmonary dysplasia: correlation of radiographic and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Breysem, L. [Department of Radiology, University Hospitals, K. U. Leuven, Herestraat 49, B-3000 Leuven (Belgium); Smet, M.H. [Department of Radiology, University Hospitals, K. U. Leuven, Herestraat 49, B-3000 Leuven (Belgium); Lierde, S. van [Department of Pediatrics, University Hospitals of Leuven, Leuven (Belgium); Devlieger, H. [Department of Pediatrics, University Hospitals of Leuven, Leuven (Belgium); Boeck, K. de [Department of Pediatrics, University Hospitals of Leuven, Leuven (Belgium); Marchal, G. [Department of Radiology, University Hospitals, K. U. Leuven, Herestraat 49, B-3000 Leuven (Belgium)

    1997-08-01

    Background and purpose. Abnormalities of the chest wall have been described in bronchopulmonary dysplasia (BPD). Clinical, radiographic and pulmonary function variables were evaluated in 1-year-old children ventilated because of neonatal lung disease in order to quantify these thoracic changes and to evaluate the lung disease. Methods. The pulmonary status of 51 infants with neonatal lung disease requiring artificial ventilation was reevaluated clinically and radiographically at the age of 1 year. Twenty-two of these infants had developed BPD. Thoracic depth and width were measured clinically and on chest X-ray. The Toce score evaluated the presence of cardiomegaly, hyperinflation, emphysema and interstitial lung disease. Lung function was measured after sedation using previously reported methods. In BPD patients, Toce score and lung function were determined and compared at 1 month and at 1 year of age. Results. In BPD patients, chest depth was significantly smaller when measured clinically as well as on chest radiograph (P < 0.05; Mann-Whitney U-test). There was a statistically significant correlation between chest depth measured clinically and on chest X-ray. Toce score was significantly higher in BPD patients (P < 0.05). In BPD patients intersitial abnormalities and decreased lung compliance were more frequent at the age of 1 month than at the age of 1 year. At the age of 1 year, hyperinflation was more frequent and at that time increased airway resistance was still noted. Thus the type of X-ray abnormality reflects the type of lung function disturbance. Conclusion. The flatness of the chest is most likely a consequence of the long-standing lung function abnormalities. (orig.). With 3 figs., 6 tabs.

  13. Descriptive quantitative analysis of hallux abductovalgus transverse plane radiographic parameters.

    Science.gov (United States)

    Meyr, Andrew J; Myers, Adam; Pontious, Jane

    2014-01-01

    Although the transverse plane radiographic parameters of the first intermetatarsal angle (IMA), hallux abductus angle (HAA), and the metatarsal-sesamoid position (MSP) form the basis of preoperative procedure selection and postoperative surgical evaluation of the hallux abductovalgus deformity, the so-called normal values of these measurements have not been well established. The objectives of the present study were to (1) evaluate the descriptive statistics of the first IMA, HAA, and MSP from a large patient population and (2) to determine an objective basis for defining "normal" versus "abnormal" measurements. Anteroposterior foot radiographs from 373 consecutive patients without a history of previous foot and ankle surgery and/or trauma were evaluated for the measurements of the first IMA, HAA, and MSP. The results revealed a mean measurement of 9.93°, 17.59°, and position 3.63 for the first IMA, HAA, and MSP, respectively. An advanced descriptive analysis demonstrated data characteristics of both parametric and nonparametric distributions. Furthermore, clear differentiations in deformity progression were appreciated when the variables were graphically depicted against each other. This could represent a quantitative basis for defining "normal" versus "abnormal" values. From the results of the present study, we have concluded that these radiographic parameters can be more conservatively reported and analyzed using nonparametric descriptive and comparative statistics within medical studies and that the combination of a first IMA, HAA, and MSP at or greater than approximately 10°, 18°, and position 4, respectively, appears to be an objective "tipping point" in terms of deformity progression and might represent an upper limit of acceptable in terms of surgical deformity correction.

  14. [Panoramic radiograph in edentulous and partially edentulous patients].

    Science.gov (United States)

    Angulo, F

    1989-01-01

    A group of two hundred patients from the School of Dentistry, UCV were study using panoramic RX, in order to determined the incidence of impacted roots, impacted teeth, radiographic feature (radiolucent and radiopaque) and foreign body. From the 200 patient 118 (59%) were edentulous and 82 (415) partially edentulous, from of clinically point of view; 40 (20%) were male and 160 (80%) female. From the total sample only 77 (38.5%) showed radiographic feature meanwhile 123 (61.5%) had not any present. Only the patients with radiographic feature were considered and the result according the age were the following: 18 patients 20-40 years old (23.4%); 41 patients 41-60 years old (53.2%) and 18 patients 61-80 years old (23.4%). The higher numbers of feature were observed in the range of age 41-60 years old. In relation to the form there was a predominance of diffuse form (53.3%). However, the size was greater of 5 mm. (43.3%). On the other hand, the higher numbers of feature were observed in the area 456 in the mandible (50%). This findings are in agreement with the result found by Jones & et al (1985) (J. Prosthet Dent 53:535-539). This values are in the same range 20-60% founded in other countries. No significant difference were founded between the partially or totally edentulous patients. This work suggest the important of the panoramic RX as a diagnostic aid before a prosthetic treatment.

  15. RADIOGRAPHIC THORACIC ANATOMY OF THE RED PANDA (AILURUS FULGENS).

    Science.gov (United States)

    Makungu, Modesta; du Plessis, Wencke M; Barrows, Michelle; Groenewald, Hermanus B; Koeppel, Katja N

    2016-09-01

    The red panda ( Ailurus fulgens ) is classified as an endangered species by the International Union for Conservation of Nature and Natural Resources. The natural distribution of the red panda is in the Himalayas and southern China. Thoracic diseases such as dirofilariasis, hypertrophic cardiomyopathy, tracheal obstruction, lung worm infestation, and pneumonia have been reported in the red panda. The aim of this study was to describe the normal radiographic thoracic anatomy of captive red pandas as a species-specific reference for routine health examinations and clinical cases. Right lateral (RL) and dorsoventral (DV) inspiratory phase views of the thorax were obtained in 11 adult captive red pandas. Measurements were made and ratios calculated to establish reference ranges for the mean vertebral heart score on the RL (8.34 ± 0.25) and DV (8.78 ± 0.34) views and the mean ratios of the caudal vena cava diameter to the vertebral body length above tracheal bifurcation (0.67 ± 0.05) and tracheal diameter to the width of the third rib (2.75 ± 0.24). The majority of animals (10/11) had 14 thoracic vertebrae, except for one animal that had 15 thoracic vertebrae. Rudimentary clavicles were seen in 3/11 animals. The ovoid, oblique cardiac silhouette was more horizontally positioned and elongated in older animals. A redundant aortic arch was seen in the oldest animal. The trachea was seen with mineralized cartilage rings in all animals. The carina was clearly seen in the majority of animals (10/11). Variations exist in the normal radiographic thoracic anatomy of different species. Knowledge of the normal radiographic thoracic anatomy of the red panda should prove useful for routine health examinations and in the diagnosis of thoracic diseases.

  16. On being dyslexic: Student radiographers' perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Fred, E-mail: f.j.murphy@salford.ac.u [Directorate of Radiography, School of Health Sport and Rehabilitation Sciences, University of Salford, Greater Manchester, M6 6PU (United Kingdom)

    2011-05-15

    The purpose of this paper was to provide an insight into life as a dyslexic student radiographer, identify barriers and risks in clinical training, and develop recommendations for the support of students with dyslexia. The paucity of research into dyslexia within the radiography profession is worrying, with attention focused only on the support provided by Higher Education Institutions (HEI) or inferences drawn from the experiences of other healthcare students. The impact and significance of dyslexia for student radiographers in clinical practice has never been investigated. Results: On a self-reporting scale of clinical tasks there was little or no difference between dyslexic students and non-dyslexics. Some minor traits commonly associated with dyslexics were also reported by students with no learning disabilities and an inclusion support plan for all students was advocated. In-depth interviews of 10 student radiographers revealed six distinct themes of visualising the disability, self-protection, strengths and talents, time, the badge of disability and adjustments and support. Like other healthcare students, some radiography students reported significant difficulties and prejudices and very little structured support in the clinical environment. Despite the Special Educational Needs and Disability Act being in place for several years, the support in clinical departments fell significantly short of that provided in the universities. The dyslexic students took extra responsibility for their own learning and some had developed complex coping strategies to overcome any difficulties. Conclusion: Several inclusive recommendations were developed as a result of this study that could be used to support all students on clinical placement.

  17. Effectiveness of Adalimumab in Non-radiographic Axial Spondyloarthritis

    Science.gov (United States)

    Cantarini, Luca; Fabbroni, Marta; Talarico, Rosaria; Costa, Luisa; Caso, Francesco; Cuneo, Gian Luca; Frediani, Bruno; Faralli, Gabriele; Vitale, Antonio; Brizi, Maria Giuseppina; Sabadini, Luciano; Galeazzi, Mauro

    2015-01-01

    Abstract The primary aim of the study was to evaluate the long-term effectiveness of adalimumab (ADA) in a cohort of non-radiographic axial spondyloarthritis (nr-axSpA), and the secondary aims were to identify predictive factors of response and evaluate radiological progression. We evaluated 37 patients (male/female: 12/25; mean age 49 ± 14; mean disease duration: 6.3 ± 5.8) with active nr-axSpA (Assessment of SpondyloArthritis International Society criteria), despite the treatment with ≥1 nonsteroidal anti-inflammatory drug for at least 3 months, initiating the treatment with ADA 40 mg every other week. Patients were treated for 24 months, and evaluated at baseline, 6, 12, and 24 months. Outcome measures included Ankylosing Spondylitis Disease Activity Score, Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), and Bath Ankylosing Spondylitis Functional Index. Radiograph of the spine and sacroiliac joints and magnetic resonance of the sacroiliac joints were performed at baseline and according to the standard of assessment for the disease. The proportion of patients that achieved a BASDAI50 response at 6, 12 and 24 months was 51.3%, 70.3%, and 76.8%, respectively. Treatment was well tolerated with no unexpected adverse events and/or serious adverse events. All patients remained on treatment for 2 years, with a good compliance. We did not identify any predictive factor of response to therapy. Moreover, modified Stoke Ankylosing Spondylitis Spine Score and Spondyloarthritis Research Consortium of Canada scores showed a trend of improvement during the study period. ADA was effective on clinical and radiological outcomes at 2-year follow-up; thus, early treatment with ADA may prevent radiographic damage and be associated with low disease activity or remission. Moreover, data from this cohort study have confirmed safety and tolerability profile of ADA in nr-axSpA in the long term. PMID:26222847

  18. Primary radiographic diagnosis of fractures in the mandible.

    Science.gov (United States)

    Moilanen, A

    1982-10-01

    A retrospective study was performed to determine the reliability of primary radiography in evaluation of fractures in the mandible. In all, radiographic diagnosis was correct in 77% of 272 fractures. Panoramic tomography (PT) was superior compared with conventional methods (skull films and jaw projections) in the assessment of these fractures. Without PT, the diagnostic error rate increased to 40%, largely due to missed fracture lines. It is recommended that PT be performed in all cases of suspected jaw fractures, initially, when obtainable, or at least once during the treatment of a jaw trauma patient. Fractures in the dento-alveolar and condylar regions, particularly, presented repeated difficulties in initial radiography.

  19. Shoulder arthroplasty. Part 2: Normal and abnormal radiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Sheridan, B.D., E-mail: bdsheridan@hotmail.com [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom); Ahearn, N.; Tasker, A.; Wakeley, C.; Sarangi, P. [Department of Orthopaedic Surgery, Bristol Royal Infirmary, Bristol (United Kingdom)

    2012-07-15

    Frequently, the decision made by general practitioners or musculoskeletal triage assessment services to refer patients for specialist review is initiated by a radiological report. Following shoulder arthroplasty it is important to ensure that any patient with asymptomatic evidence of a failing prosthesis is referred for review so that revision surgery can be contemplated and planned before the situation becomes unsalvageable. The first paper in this series described the various types of shoulder arthroplasty and indications for each. This follow-up paper will concentrate on their modes of failure and the associated radiographic features, and is aimed at radiology trainees and non-musculoskeletal specialist radiologists.

  20. Oblique lumbar spine radiographs: importance in young patients

    Energy Technology Data Exchange (ETDEWEB)

    Libson, E.; Bloom, R.A.; Dinari, G.; Robin, G.C.

    1984-04-01

    Spondylolysis is a direct precursor of spondylolisthesis and can lead to crippling back pain. Of 1,743 patients surveyed, including 936 who were asymptomatic and 807 with back pain, 165 (including 91 who were asymptomatic and 74 with back pain) had spondylolysis, which was seen only on oblique lumbar views in 20% of cases. Because of the high false-negative rate of AP and lateral views, oblique views are essential in children and young adults. As spondylolysis is rare above L3, radiographs can be limited to L3-S1. Significantly less spondylolysis was seen in persons older than 30 with back pain usually caused by disk degeneration.

  1. Inappropriate mode switching clarified by using a chest radiograph.

    Science.gov (United States)

    Marino, Brian; Jaiswal, Abhishek; Goldbarg, Seth

    2015-08-01

    An 80-year-old woman with a history of paroxysmal atrial fibrillation and atrioventricular node disease status post-dual chamber pacemaker placement was noted to have abnormal pacing episodes during a percutaneous coronary intervention. Pacemaker interrogation revealed a high number of short duration mode switching episodes. Representative electrograms demonstrated high frequency nonphysiologic recordings predominantly in the atrial lead. Intrinsic pacemaker malfunction was excluded. A chest radiograph showed excess atrial and ventricular lead slack in the right ventricular inflow. It was suspected that lead-lead interaction resulted in artifacts and oversensing, causing frequent short episodes of inappropriate mode switching.

  2. Study on the nuchal ligament ossification on lateral cephalometric radiograph

    Energy Technology Data Exchange (ETDEWEB)

    An, Chang Hyeon [Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    2009-03-15

    The purpose of this study was to assess the prevalence and radiographic characteristics of the nuchal ligament ossification on lateral cephalometric radiographs in Koreans. I review and interpreted the lateral cephalometric radiographs from 4,558 patients (1,857 males and 2,701 females, age range from 2 to 79 years) who visited the Kyungpook National University Dental Hospital from January 1, 2008 to February 3, 2009. I grouped the shapes of nuchal ligament ossification as round, rod-like, and segmented shape. And localized the ossification as the involvement of anterior cervical vertebral body. The data were analyzed by using chi-squared test with two-tailed and at a 5% significance level. Among those who showed the nuchal ligament ossification, the mean age of the 143 males was 51.1 and that of the 97 females was 48.0 years. It was not observed completely below teens, and was observed 1% in twenties, 6.1% in thirties, 18.6% in forties, and 26.3% over fifties. It was significantly prevalent in older age group (P<0.01) and in males than females among the same age group (P<0.05). The shapes of nuchal ligament ossification were as follows in order of frequency : rod-like (49.2%), round (30.4%), and segmented (20.4%). The highest involvement of ossification was found at the level of C5 (67.9%), C4 (29.2%), C6 (22.9%), C3 (3.3%), C7 (2.9%), C2 (0.8%), and C1 (0.4%). The nuchal ligament ossifications on lateral cephalometric radiographs were showed as round, rodlike, or segmented shape. The nuchal ligament ossification is often observed after the age of 40 and is observed more frequently in males than females. The highest shape of nuchal ligament ossification was rod-like shape and the highest involvement of cervical spine was C5.

  3. Diabetic mastopathy as a radiographically occult palpable breast mass.

    Science.gov (United States)

    Thanarajasingam, Uma; Chen, Beiyun; Tortorelli, Cindy L; Jakub, James W; Ghosh, Karthik

    2011-01-01

    Diabetic mastopathy is an uncommon, benign disease of the breast that can occur in women with diabetes and clinically mimic breast cancer. We describe a patient with long-standing type 1 diabetes who presented with a palpable breast mass with negative imaging findings on mammography, ultrasonography, and breast MRI. Surgical biopsy and histopathology confirmed diabetic mastopathy. We use this case to highlight the recognition, radiographic features, pathology, and management of this benign breast condition and emphasize that, in diabetic patients, the differential diagnosis of a new breast mass should include diabetic mastopathy.

  4. Diabetic Mastopathy as a Radiographically Occult Palpable Breast Mass

    Directory of Open Access Journals (Sweden)

    Uma Thanarajasingam

    2011-01-01

    Full Text Available Diabetic mastopathy is an uncommon, benign disease of the breast that can occur in women with diabetes and clinically mimic breast cancer. We describe a patient with long-standing type 1 diabetes who presented with a palpable breast mass with negative imaging findings on mammography, ultrasonography, and breast MRI. Surgical biopsy and histopathology confirmed diabetic mastopathy. We use this case to highlight the recognition, radiographic features, pathology, and management of this benign breast condition and emphasize that, in diabetic patients, the differential diagnosis of a new breast mass should include diabetic mastopathy.

  5. Computer-assisted quality assurance for radiographic equipment.

    Science.gov (United States)

    Glaze, S; Schneiders, N; Archer, B; Bushong, S

    1980-01-01

    A quality assurance procedure which includes a computer program has been implemented to facilitate measurement of some of the parameters normally tested on diagnostic radiographic equipment. These include: reproducibility of output, linearity of mA settings, filtration, kVp calibration, timer error, SID indication, light field--x-ray field coincidence and effective focal spot size. The user may omit those sections which are not applicable to his needs. Full use is made of the data reducing the number of field measurements needed.

  6. Radiographic appearances of uncommon paediatric implants and devices

    Energy Technology Data Exchange (ETDEWEB)

    Urquia, Arlen; Watson, Tom A.; Arthurs, Owen J. [Great Ormond Street Hospital NHS Foundation Trust, Department of Radiology, London (United Kingdom)

    2015-06-15

    As childhood survival of chronic illness improves, long-term implanted devices will be encountered more frequently in routine radiology. In our paediatric tertiary referral hospital, we have come across several types of implanted devices that were not confidently recognised or identified by front-line staff and were often only identified by discussion with the patient, family or clinical team. This pictorial review highlights the appearance of nonvascular devices on paediatric radiographs in order to help clinicians identify the most frequent complications and to improve awareness of these important devices. (orig.)

  7. Optical and radiographical characterization of silica aerogel for Cherenkov radiator

    CERN Document Server

    Tabata, Makoto; Hatakeyama, Yoshikiyo; Kawai, Hideyuki; Morita, Takeshi; Nishikawa, Keiko

    2012-01-01

    We present optical and X-ray radiographical characterization of silica aerogels with refractive index from 1.05 to 1.07 for a Cherenkov radiator. A novel pin-drying method enables us to produce highly transparent hydrophobic aerogels with high refractive index by shrinking wet-gels. In order to investigate the uniformity in the density (i.e., refractive index) of an individual aerogel monolith, we use the laser Fraunhofer method, an X-ray absorption technique, and Cherenkov imaging by a ring imaging Cherenkov detector in a beam test. We observed an increase in density at the edge of the aerogel tiles, produced by pin-drying.

  8. Gold-wire artifacts on diagnostic radiographs: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Keestra, Johan Anton Jochum; Jacobs, Reinhilde; Quirynen, Marc [Dept. of Oral Health Sciences, KU Leuven and Dentistry, University Hospitals, KU Leuven, Leuven (Belgium)

    2014-03-15

    This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

  9. Severe acute respiratory syndrome (SARS): chest radiographic features in children

    Energy Technology Data Exchange (ETDEWEB)

    Babyn, Paul S.; Gahunia, Harpal K.; Manson, David [Department of Diagnostic Imaging, Hospital for Sick Children, 555 University Avenue, Toronto, Ontario (Canada); Chu, Winnie C.W.; Metreweli, Constantine [Prince of Wales Hospital, Shatin (China); Department of Diagnostic Radiology and Organ Imaging, Chinese University of Hong Kong (China); Tsou, Ian Y.Y.; Wansaicheong, Gervais K.L.; Chee, Thomas S.G.; Kaw, Gregory J.L. [Department of Diagnostic Radiology, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng (Singapore); Allen, Upton; Bitnun, Ari; Read, Stanley [Division of Infectious Diseases, Hospital for Sick Children, 555 University Avenue, Toronto, Ontario (Canada); Cheng, Frankie W.T.; Fok, Tai-Fai; Hon, Ellis K.L.; Li, Albert M.; Ng, Pak-Cheung [Department of Paediatrics, Chinese University of Hong Kong, Prince of Wales Hospital, 30-32 Ngan Shing Street, Shatin, Hong Kong, SAR (China); Chiu, Man-Chun; Leung, Chi-Wai [Department of Paediatrics and Adolescent Medicine, Princess Margaret Hospital, Lai King Hill Road, Lai Chi Kok, Hong Kong, SAR (China); Khong, Pek L. [Department of Diagnostic Radiology, The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong, SAR (China); Stringer, David A.

    2004-01-01

    We abstracted data (n=62) on the radiologic appearance and course of SARS in pediatric patients with suspect (n=25) or probable (n=37) SARS, diagnosed in five hospital sites located in three cities: Toronto, Singapore, and Hong Kong. Available chest radiographs and thoracic CTs were reviewed for the presence of the following radiographic findings: airspace disease, air bronchograms, airways inflammation and peribronchial thickening, interstitial disease, pleural effusion, and hilar adenopathy. A total of 62 patients (suspect=25, probable=37) were evaluated for SARS. Patient ages ranged from 5.5 months to 17 years and 11.5 months (average, 6 years and 10 months) with a female-to-male ratio of 32:30. Forty-one patients (66.1%) were in close contact with other probable, suspect, or quarantined cases; 10 patients (16.1%) had recently traveled to WHO-designated affected areas within 10 days; and 7 patients (11.2%) were transferred from other hospitals that had SARS patients. Three patients, who did not have close/hospital contact or travel history to affected areas, were classified as SARS cases based on their clinical signs and symptoms and on the fact that they were living in an endemic area. The most prominent clinical presentations were fever, with a temperature over 38 C (100%), cough (62.9%), rhinorrhea (22.6%), myalgia (17.7%), chills (14.5%), and headache (11.3%). Other findings included sore throat (9.7%), gastrointestinal symptoms (9.7%), rigor (8.1%), and lethargy (6.5%). In general, fever and cough were the most common clinical presentations amongst younger pediatric SARS cases (age<10 years), whereas, in addition to these symptoms, headache, myalgia, sore throat, chills, and/or rigor were common in older patients (age{>=}10 years). The chest radiographs of 35.5% of patients were normal. The most prominent radiological findings that were observed in the remaining patients were areas of consolidation (45.2%), often peripheral with multifocal lesions in 22

  10. A Study on Reactive Ion Etching of Barium Strontium Titanate Films Using Mixtures of Argon (Ar), Carbon Tetrafluoride (CF4), and Sulfur Hexafluoride (SF6)

    Science.gov (United States)

    2014-07-01

    A Study on Reactive Ion Etching of Barium Strontium Titanate Films Using Mixtures of Argon (Ar), Carbon Tetrafluoride (CF4), and Sulfur...Etching of Barium Strontium Titanate Films Using Mixtures of Argon (Ar), Carbon Tetrafluoride (CF4), and Sulfur Hexafluoride (SF6) Samuel G...Study on Reactive Ion Etching of Barium Strontium Titanate Films Using Mixtures of Argon (Ar), Carbon Tetrafluoride (CF4), and Sulfur Hexafluoride

  11. Is carbon dioxide as an insufflation agent for double contrast barium enema still worthwhile after a same-day flexible sigmoidoscopy?

    Energy Technology Data Exchange (ETDEWEB)

    Asao, Takayuki; Fujita, Kin-ichi; Nakamura, Jun-ichi; Morinaga, Nobuhiro; Shoji, Hisanori; Ide, Munenori; Hirayama, Isao; Kuwano, Hiroyuki

    2002-06-01

    PURPOSE: The aim of the study was to evaluate the efficacy of a double-contrast barium enema (DCBE) with CO{sub 2} as a distending gas after a screening flexible sigmoidoscopy for reducing abdominal distension after an examination. PATIENTS AND METHODS: A total of 165 DCBEs for patients with positive faecal occult blood tests were randomly allocated to a CO{sub 2} group (n = 83) and a control group (n = 82) using air. Abdominal radiograph were taken before the DCBE, immediately following it, and 30 minutes later to determine residual bowel gas. The degree of abdominal discomfort was recorded using a scoring system. RESULTS: The patients in the CO{sub 2} group had significantly smaller amounts of residual gas 30 minutes after the DCBE than did the control group, both in the colon (P < 0.02) and in the small intestine (P < 0.001). There was significantly less abdominal distension after the DCBE in the CO{sub 2} group compared to the control group (P < 0.001). The abdominal discomfort score at 30 minutes after CO{sub 2} correlated with the residual gas in the small intestine(r = 0.390,P = 0.003) but not in the colon(r = 0.155, P 0.15). The quality of the images and the number of polyps detected did not differ between two groups. CONCLUSIONS: We concluded that using CO{sub 2} when administering a DCBE after a screening sigmoidoscopy was useful for relieving abdominal discomfort following the examination; furthermore, it did not impair the diagnostic ability of the DCBE. Asao, T. (2002)

  12. Comparison of Barium and Arsenic Concentrations in Well Drinking Water and in Human Body Samples and a Novel Remediation System for These Elements in Well Drinking Water.

    Directory of Open Access Journals (Sweden)

    Masashi Kato

    Full Text Available Health risk for well drinking water is a worldwide problem. Our recent studies showed increased toxicity by exposure to barium alone (≤700 µg/L and coexposure to barium (137 µg/L and arsenic (225 µg/L. The present edition of WHO health-based guidelines for drinking water revised in 2011 has maintained the values of arsenic (10 µg/L and barium (700 µg/L, but not elements such as manganese, iron and zinc. Nevertheless, there have been very few studies on barium in drinking water and human samples. This study showed significant correlations between levels of arsenic and barium, but not its homologous elements (magnesium, calcium and strontium, in urine, toenail and hair samples obtained from residents of Jessore, Bangladesh. Significant correlation between levels of arsenic and barium in well drinking water and levels in human urine, toenail and hair samples were also observed. Based on these results, a high-performance and low-cost adsorbent composed of a hydrotalcite-like compound for barium and arsenic was developed. The adsorbent reduced levels of barium and arsenic from well water in Bangladesh and Vietnam to <7 µg/L within 1 min. Thus, we have showed levels of arsenic and barium in humans and propose a novel remediation system.

  13. Cases report of ossifying fibroma showing various radiographic appearances in posterior mandible

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Do; Oh, Seung Hwan [School of Dentistry, Wonkwang University, Seoul (Korea, Republic of); Son, Hyun Jin [Department of Pathology, School of Medicine, Eulji University, Daejeon (Korea, Republic of)

    2010-06-15

    Common radiographic appearances of ossifying fibroma (OF) are well demarcated margin, radiolucent or mixed lesion. Lesions for the radiographic differential diagnosis with OF include fibrous dysplasia, focal cemento-osseous dysplasia. Other confusing lesions might be the mixed lesions such as calcifying odontogenic cyst, adenomatoid odontogenic tumor, calcifying epithelial odontogenic tumor, and benign cementoblastoma. We reported three cases of OF in posterior mandible. These cases showed a little distinguished radiographic features of OF and diagnosed from a combination of clinical, radiographic, and histopathologic information. We need to further refine radiographic and histopathological features of OF and other confusing lesions with literatures review because some cases of these lesions are not easily differentiated radiographically and histopathologically.

  14. [Using barium fluoride fine particles as stationary phase for TLC/FTIR analysis].

    Science.gov (United States)

    Liu, Xi; Pan, Qing-hua; Ding, Jie; Zhu, Qing; He, An-qi; Yue, Shi-juan; Li, Xiao-pei; Hu, Li-ping; Xia, Jin-ming; Liu, Cui-ge; Wei, Yong-ju; Yu, Jiang; Yang, Zhan-lan; Zhu, Xi; Xu, Yi-zhuang; Wu, Jin-guang

    2011-07-01

    In situ TLC/FTIR technique has tremendous potential in the analysis of complex mixtures. However, the progress in this technique was quite slow. The reason is that conventional stationary phase such as silica gel etc. has strong absorption in FTIR spectrum and thus brings about severe interference in the detection of samples. To solve the problem, the authors propose to use barium fluoride fine particles as stationary phase of TLC plate. The reasons are as follows: Barium fluoride wafer has been extensively used as infrared window in FTIR experiments and it has no absorbance in an IR region between 4 000 and 800 cm'. As a matter of fact, the atomic mass of barium and fluoride is quite large, thus the normal vibration of BaF2 lattice is limited in far-IR region and low frequency part of mid-IR region. Therefore, the interference caused by IR absorption of stationary phase can be resolved if BaF2 is used as stationary phase of TLC plate. Moreover, BaF2 is quite stable and insolvable in water and most organic solvents and it will not be dissolved by mobile phase or react with samples in TLC separation. Additionally, decreasing the particle size of BaF2 is very important in TLC/FTIR analysis technique. The reason is two-fold: First, decreasing the particle size of stationary phase is helpful to improving the efficiency of separation by TLC plate; second, decreasing the size of BaFz particle can improve the quality of FTIR spectra by alleviating the problem of light scattering. By optimizing the synthetic conditions, fine particles of barium fluoride were obtained. SEM results indicate that the size of the BaF2 particles is around 500 nm. FTIR spectrum of the BaF2 particles shows that no absorption of impurity was observed. Moreover, the elevation of baseline caused by light scattering is insignificant. The authors have developed a new technique named "settlement volatilization method" to prepare TLC plate without polymeric adhesive that may bring about significant

  15. Radiographic study of dental anomalies in brazilian patients with neuropsychomotor disorders

    OpenAIRE

    Erick Nelo Pedreira; Marina Cury Gallotini Magalhães; Camila Lopes Cardoso; Luís Antônio de Assis Taveira; Cláudio Froes de Freitas

    2007-01-01

    The purposes of this study were to investigate radiographically the dental and maxillomandibular in patients with neuropsychomotor disorders and determine the role of panoramic radiographs for quantitative and qualitative analyses of dental alterations. A total of 322 panoramic radiographs from 190 males and 132 females aged 4 to 57 years were obtained from the files of the Center for Care to Patients with Special Needs (CAPE; Dental School, University of São Paulo) and subdivided into syndro...

  16. Silicosis and tuberculosis: a proposed radiographic classification of tuberculosis to accompany the ILO international classification of radiographs of pneumoconioses.

    Science.gov (United States)

    Solomon, A; Rees, D; Felix, M; Venter, E

    2000-01-01

    A significant proportion of workers exposed to silica dust are at risk of developing tuberculosis (TB). The higher the International Labor Organization (ILO) category of silicosis, the greater the TB risk. Subtle radiographic presentations of TB may be the initial manifestation of TB, particularly in the absence of sputum identification of TB bacilli. A proposed TB x-ray-reading form in addition to the ILO categorization of silicosis is offered. The implementation of a standardized TB x-ray-reading approach should alert the clinician to indolent TB lesions.

  17. Segmentation of hand radiographs using fast marching methods

    Science.gov (United States)

    Chen, Hong; Novak, Carol L.

    2006-03-01

    Rheumatoid Arthritis is one of the most common chronic diseases. Joint space width in hand radiographs is evaluated to assess joint damage in order to monitor progression of disease and response to treatment. Manual measurement of joint space width is time-consuming and highly prone to inter- and intra-observer variation. We propose a method for automatic extraction of finger bone boundaries using fast marching methods for quantitative evaluation of joint space width. The proposed algorithm includes two stages: location of hand joints followed by extraction of bone boundaries. By setting the propagation speed of the wave front as a function of image intensity values, the fast marching algorithm extracts the skeleton of the hands, in which each branch corresponds to a finger. The finger joint locations are then determined by using the image gradients along the skeletal branches. In order to extract bone boundaries at joints, the gradient magnitudes are utilized for setting the propagation speed, and the gradient phases are used for discriminating the boundaries of adjacent bones. The bone boundaries are detected by searching for the fastest paths from one side of each joint to the other side. Finally, joint space width is computed based on the extracted upper and lower bone boundaries. The algorithm was evaluated on a test set of 8 two-hand radiographs, including images from healthy patients and from patients suffering from arthritis, gout and psoriasis. Using our method, 97% of 208 joints were accurately located and 89% of 416 bone boundaries were correctly extracted.

  18. Chest Radiographs for Pediatric TB Diagnosis: Interrater Agreement and Utility

    Directory of Open Access Journals (Sweden)

    G. Kaguthi

    2014-01-01

    Full Text Available The chest radiograph (CXR is considered a key diagnostic tool for pediatric tuberculosis (TB in clinical management and endpoint determination in TB vaccine trials. We set out to compare interrater agreement for TB diagnosis in western Kenya. A pediatric pulmonologist and radiologist (experts, a medical officer (M.O, and four clinical officers (C.Os with basic training in pediatric CXR reading blindly assessed CXRs of infants who were TB suspects in a cohort study. C.Os had access to clinical findings for patient management. Weighted kappa scores summarized interrater agreement on lymphadenopathy and abnormalities consistent with TB. Sensitivity and specificity of raters were determined using microbiologically confirmed TB as the gold standard (n=8. A total of 691 radiographs were reviewed. Agreement on abnormalities consistent with TB was poor; k=0.14 (95% CI: 0.10–0.18 and on lymphadenopathy moderate k=0.26 (95% CI: 0.18–0.36. M.O [75% (95% CI: 34.9%–96.8%] and C.Os [63% (95% CI: 24.5%–91.5%] had high sensitivity for culture confirmed TB. TB vaccine trials utilizing expert agreement on CXR as a nonmicrobiologically confirmed endpoint will have reduced specificity and will underestimate vaccine efficacy. C.Os detected many of the bacteriologically confirmed cases; however, this must be interpreted cautiously as they were unblinded to clinical features.

  19. CHANGES IN RADIOGRAPHIC PARAMETERS AFTER MINIMALLY INVASIVE LUMBAR INTERBODY FUSION

    Directory of Open Access Journals (Sweden)

    Emiliano Vialle

    2015-12-01

    Full Text Available Objective : This study aims to evaluate changes in lumbosacral parameters after minimally invasive lumbar interbody fusion. The secondary aim was to evaluate whether interbody cage shape (crescent shaped or rectangular would influence the results. Method : Retrospective analysis of 70 patients who underwent one or two level lumbar interbody fusion through a minimally invasive posterolateral approach. This included midline preservation and unilateral facetectomy. Pre- and postoperative (three to six months postoperative radiographs were used for measuring lumbar lordosis (LL, segmental lordosis (SL at the level of interbody fusion, and sacral slope (SS. Further analyses divided the patients into Roussouly lumbar subgroups. Results : LL was significantly reduced after surgery (59o:39o, p=0.001 as well as the SS (33.8o:31.2o, p=0.05. SL did not change significantly (11.4:11.06, p=0.85. There were no significant differences when comparing patients who received crescent shaped cage (n=27 and rectangular cage (n=43. Hypolordotic patients (Roussouly types 1 and 2 had radiographic improvement in comparison to normolordotic and hyperlordotic groups (types 3 and 4. Conclusion : Minimally invasive lumbar interbody fusion caused reduction in lumbosacral parameters. Cage shape had no influence on the results.

  20. Patient-based radiographic exposure factor selection: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Ching, William; Robinson, John; McEntee, Mark, E-mail: mark.mcentee@sydney.edu.au [Discipline of Medical Radiation Sciences, University of Sydney, Lidcombe, New South Wales (Australia)

    2014-09-15

    Digital technology has wider exposure latitude and post-processing algorithms which can mask the evidence of underexposure and overexposure. Underexposure produces noisy, grainy images which can impede diagnosis and overexposure results in a greater radiation dose to the patient. These exposure errors can result from inaccurate adjustment of exposure factors in response to changes in patient thickness. This study aims to identify all published radiographic exposure adaptation systems which have been, or are being, used in general radiography and discuss their applicability to digital systems. Studies in EMBASE, MEDLINE, CINAHL and SCOPUS were systematically reviewed. Some of the search terms used were exposure adaptation, exposure selection, exposure technique, 25% rule, 15% rule, DuPont™ Bit System and radiography. A manual journal-specific search was also conducted in The Radiographer and Radiologic Technology. Studies were included if they demonstrated a system of altering exposure factors to compensate for variations in patients for general radiography. Studies were excluded if they focused on finding optimal exposures for an ‘average’ patient or focused on the relationship between exposure factors and dose. The database search uncovered 11 articles and the journal-specific search uncovered 13 articles discussing systems of exposure adaptation. They can be categorised as simple one-step guidelines, comprehensive charts and computer programs. Only two papers assessed the efficacy of exposure adjustment systems. No literature compares the efficacy of exposure adaptations system for film/screen radiography with digital radiography technology nor is there literature on a digital specific exposure adaptation system.

  1. Factors of patellar instability: an anatomic radiographic study.

    Science.gov (United States)

    Dejour, H; Walch, G; Nove-Josserand, L; Guier, C

    1994-01-01

    We analyzed the radiographs and computed tomography (CT) scans of 143 knees operated on for symptomatic patellar instability and 67 contralateral asymptomatic knees, together with 190 control knee radiographs and 27 control knee scans, to determine the factors affecting patellar instability. Four factors were relevant in knees with symptomatic patellar instability: (1) Trochlear dysplasia (85%), as defined by the crossing sign (96%) and quantitatively expressed by the trochlear bump, pathological above 3 mm or more (66%), and the trochlear depth, pathologic at 4 mm or less. (2) Quadriceps dysplasia (83%), defined a present when the patellar tilt in extension is more than 20% on the CT scans. (3) Patella alta (Caton-Deschamps) index greater than or equal to 1.2 (24%). (4) Tibial tuberosity-trochlear groove, pathological when greater than or equal to 20 mm (56%). The factors appeared in only 3%-6.5% of the control knees. The etiology of patellar instability is multifactorial. Determination of the factors permits an effective elective therapeutic plan which aims at correcting the anomalies present.

  2. Effect of biologic agents on radiographic progression of rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Gabriel J Tobón

    2010-08-01

    Full Text Available Gabriel J Tobón1, Alain Saraux1,2, Valérie Devauchelle-Pensec1,21Immunology Laboratory, Morvan Hospital, Université de Bretagne Occidentale, Brest, France; 2Rheumatology Unit, Hôpital de la Cavale Blanche, CHU Brest, FranceAbstract: The treatment of rheumatoid arthritis (RA has benefited over the last few years from the introduction of biologic agents whose development was based on new insights into the immunological factors involved in the pathogenesis of RA and the development of joint damage. These biological agents have been proven effective in RA patients with inadequate responses to synthetic disease-modifying antirheumatic drugs (DMARDs. Preventing joint damage is now the primary goal of RA treatment, and guidelines exist for the follow-up of joint abnormalities. Most biologic agents produced high clinical and radiological response rates in patients with established or recent-onset RA. Thus, for the first time, obtaining a remission is a reasonable treatment goal in RA patients. Factors that are crucial to joint damage control are: early initiation of DMARDs, use of intensive treatments including biological agents, and close monitoring of clinical disease activity and radiographic progression. However, some patients remain unresponsive to all available treatments and continue to experience joint damage progression. A major objective now is to identify patients at high risk for severe joint damage, in order to tailor the treatment regimen to their specific needs.Keywords: rheumatoid arthritis, radiographic progression, biologics

  3. Radiographic features of teriparatide-induced healing of femoral fractures

    Directory of Open Access Journals (Sweden)

    Youngwoo Kim

    2015-12-01

    Full Text Available Teriparatide is a drug that is used to increase bone remodeling, formation, and density for the treatment of osteoporosis. We present three cases of patients with a femoral insufficiency fracture. The patients were administered teripatatide in an attempt to treat severe osteoporosis and to enhance fracture healing. We found several radiographic features around the femoral fractures during the healing period. 1 Callus formation was found at a very early stage in the treatment. Teriparatide substantially increased the unusually abundant callus formation around the fracture site at 2 weeks. Moreover, this callus formation continued for 8 weeks and led to healing of the fracture. 2 Abundant callus formation was found circumferentially around the cortex with a ‘cloud-like’ appearance. 3 Remodeling of the teriparatide-induced callus formation was found to be part of the normal fracture healing process. After 1 year, normal remodeling was observed on plain radiographs. These findings indicate that teriparatide can be used as an adjuvant therapy in the management of femoral insufficiency fractures.

  4. Characterization of radiographic features of consecutive lumbar spondylolisthesis

    Science.gov (United States)

    Sun, Yapeng; Wang, Hui; Yang, Dalong; Zhang, Nan; Yang, Sidong; Zhang, Wei; Ding, Wenyuan

    2016-01-01

    Abstract Radiographic features of consecutive lumbar spondylolisthesis were retrospectively analyzed in a total of 17 patients treated for this condition at the Third Hospital of Hebei Medical University from June 2005 to March 2012. To investigate the radiographic features, pelvic compensatory mechanisms, and possible underlying etiologies of consecutive lumbar spondylolisthesis. To the best of our knowledge, there is no previous report concerning the characteristics of consecutive lumbar spondylolisthesis. The Taillard index and the lumbar lordosis (LL), pelvic incidence (PI), sacrum slope (SS), and pelvic tilt (PT) were determined on lateral X-ray images, and the angular displacement was analyzed on flexion–extension X-ray images. Correlation between LL and various pelvic parameters and correlation between Taillard index and angular displacement were assessed by Pearson correlation analysis. A total of 20 cases of isthmic spondylolisthesis and 14 of degenerative spondylolisthesis were retrospectively studied in 17 patients. The Taillard index and the angular displacement in the lower vertebrae were both larger than those in the upper vertebrae. Statistical analysis revealed that LL was correlated with PI and PT, whereas PI was correlated with PT and SS. However, no correlation was identified between Taillard index and angular displacement. In consecutive lumbar spondylolisthesis, the degree of vertebral slip and the angular displacement of the lower vertebrae were both greater than those of the upper vertebrae, indicating that the compensatory mechanism of the pelvis plays an important role in maintaining sagittal balance. PMID:27861359

  5. Bone and joint changes following electrical burn: plain radiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Uk Jung; Lee, Eil Seong; Shim, Ya Seong; Kim, Seon Bok; Lee, Shin Ho; Jung, Hae Kyoung; Hwang, Dae Hyun; Kang, Ik Won [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    To evaluate the plain radiographic findings of bone and joint changes following electrical burn. This study involved 19 patients with 27 bone and joints regions which had suffered electrical injury. The most common input and output sites were, respectively, the hand(7/14) and foot (6/10). Three other sites were involved. Four cases involved osteomyelitis, and in four, amputation was performed. We observed bone and joint changes, changes following osteomyelitis and changes in the amputation stump. We analyzed the difference between input and output changes, and when this was interesting, the average time of onset was assessed. In bone and joint changes following electrical burn, the most frequent radiographic finding was joint contracture(n=3D16). Other findings included osteolysis(n=3D8), articular abnormalites (n=3D6), periostitis(n=3D5), fracture(n=3D5), acro-osteolysis(n=3D2), and heterotopic bone formation(n=3D2). In cases involving osteomyelitis(n=3D4), aggravation of underlying bone changes was noted. In electrical burn, various changes were noted in bone and joints, and input injury was more severe than that of output.=20.

  6. Workplace experience of radiographers: impact of structural and interpersonal interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kubik-Huch, R.A.; Roempler, M.; Weber, A. [Kantonsspital Baden, Institute of Radiology, Baden (Switzerland); Klaghofer, R.; Buddeberg-Fischer, B. [Zurich University Hospital, Department of Psychosocial Medicine, Zurich (Switzerland)

    2010-02-15

    Within the framework of organisational development, an assessment of the workplace experience of radiographers (RGs) was conducted. The aims of this study were to develop structural and interpersonal interventions and to prove their effectiveness and feasibility. A questionnaire consisting of work-related factors, e.g. time management and communication, and two validated instruments (Workplace Analysis Questionnaire, Effort-Reward Imbalance Scale) was distributed to all RGs (n = 33) at baseline (T1). Interventions were implemented and a follow-up survey (T2) was performed 18 months after the initial assessment. At T1, areas with highest dissatisfaction were communication and time management for ambulant patients (bad/very bad, 57% each). The interventions addressed adaptation of work plans, coaching in developing interpersonal and team leadership skills, and regular team meetings. The follow-up survey (T2) showed significantly improved communication and cooperation within the team and improved qualification opportunities, whereas no significant changes could be identified in time management and in the workplace-related scales 'effort' expended at work and 'reward' received in return for the effort. Motivating workplace experience is important for high-level service quality and for attracting well-qualified radiographers to work at a place and to stay in the team for a longer period. (orig.)

  7. Electronic system for digital acquisition of rotational panoramic radiographs

    Energy Technology Data Exchange (ETDEWEB)

    McDavid, W.D.; Dove, S.B.; Welander, U.; Tronje, G. (Department of Dental Diagnostic Science, University of Texas Health Science Center, San Antonio (USA))

    1991-04-01

    A prototype system for digital panoramic imaging of the maxillofacial complex has been developed. In this system x-ray film is replaced by an electronic sensor that delivers the image information to a computer for storage in digital format. The images, which are similar to conventional panoramic radiographs, are displayed on a high-resolution video monitor and may be stored on optical disk for future use. Hard-copy output is also available. The present prototype system has been installed on an Orthopantomograph model OP10 panoramic x-ray machine is programmed for operation with this machine, but in principle the system can be installed on any such device. The system may be incorporated into the design of future panoramic x-ray systems or may be used to retrofit panoramic x-ray systems now using photographic film to record the radiographic image. Greater sensitivity of electronic sensors should make possible a reduction of x-ray dose to the patient, compared with film-based systems.

  8. Radiographic protocol and normal anatomy of the hind feet in the white rhinoceros (Ceratotherium simum).

    Science.gov (United States)

    Dudley, Robert J; Wood, Simon P; Hutchinson, John R; Weller, Renate

    2015-01-01

    Foot pathology is a common and important health concern in captive rhinoceroses worldwide, but osteopathologies are rarely diagnosed, partly because of a lack of radiographic protocols. Here, we aimed to develop the first radiographic protocol for rhinoceros feet and describe the radiographic anatomy of the white rhinoceros (Ceratotherium simum) hind foot (pes). Computed tomographic images were obtained of nine cadaver pedes from seven different white rhinoceroses and assessed for pathology. A single foot deemed free of pathology was radiographed using a range of different projections and exposures to determine the best protocol. 3D models were produced from the CT images and were displayed with the real radiographs to describe the normal radiographic anatomy of the white rhinoceros pes. An optimal radiographic projection was determined for each bone in the rhinoceros pes focusing on highlighting areas where pathology has been previously described. The projections deemed to be most useful were D60Pr-PlDiO (digit III), D45Pr45M-PlDiLO (digit II), and D40Pr35L-PlDiLO (digit IV). The primary beam was centered 5-7 cm proximal to the cuticle on the digit of interest. Articular surfaces, ridges, grooves, tubercles, processes and fossae were identified. The radiographic protocol we have developed along with the normal radiographic anatomy we have described will allow for more accessible and effective diagnosis of white rhinoceros foot osteopathologies.

  9. A prospective comparison of intestinal sonography and abdominal radiographs in a neonatal intensive care unit

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cicero T. [The University of Toronto, The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Yale University School of Medicine, New Haven, CT (United States); Daneman, Alan; Navarro, Oscar M. [The University of Toronto, The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Moineddin, Rahim [The University of Toronto, The Hospital for Sick Children, Department of Family and Community Medicine, Toronto (Canada); Levine, Daniel [The University of Toronto, The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); The Royal Marsden NHS Foundation Trust, London (United Kingdom); Moore, Aideen M. [The University of Toronto, The Hospital for Sick Children, Department of Pediatrics, Toronto (Canada)

    2013-11-15

    No study reported in the literature comprehensively compares findings on neonatal abdominal radiographs with sonography. To compare the findings on abdominal radiographs and sonograms in infants in intensive care, to better understand how the various intestinal gas patterns on radiographs relate to the spectrum of appearances on sonography and, second, to evaluate the ability of sonography to differentiate necrotizing enterocolitis from other intestinal pathology. We prospectively evaluated sonograms and radiographs, blinded to the other modality and to clinical information. Patients' charts were reviewed by a third blinded reader and used as a reference standard for diagnosis. We made associations between sonographic findings, radiographic intestinal gas patterns and clinical diagnoses. We included 75 infants with gestational ages between 23 weeks and 41 weeks. Sonographic abnormalities were present in infants with all radiographic intestinal gas patterns, including normal patterns. We only saw absent intestinal perfusion and fluid collections on sonography (suggesting intestinal necrosis and sealed perforation) in infants with intestinal dilatation with elongation on radiographs. Separation of intestinal loops on radiographs was most commonly caused by reasons other than intestinal wall thickening. Increased intestinal echogenicity or free fluid with echoes on sonography correlated with a diagnosis of necrotizing enterocolitis, whereas anechoic free fluid correlated with absence of necrotizing enterocolitis. Sonography is complementary to radiographs in infants with suspected intestinal pathology, with a spectrum of appearances seen on each modality. Some sonographic findings either strongly suggest necrotizing enterocolitis or supply evidence against this diagnosis. (orig.)

  10. Quantitative analysis of periapical lesions on cone beam computed tomograph and periapical radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hoa; Lee, Wan; Kim, Kyung Soo; Roh, Young Chea; Lee, Byung Do [Department of Oral and Maxillofacial Radiology, School of Dentistry, Wonkwang University, Iksan (Korea, Republic of); Kim, De Sok [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Deajeon (Korea, Republic of)

    2009-03-15

    To detect the progression of experimentally induced periapical lesions on periapical radiograph and cone beam computed tomograph (CBCT) by quantitative analysis. After the removal of coronal pulps from premolars of two Beagle dogs, the root canals of premolars were exposed to oral environment during one week and then sealed for 70 days. Digital periapical radiographs and CBCTs were taken at baseline and every 7 days for 77 days after pulp exposure. We examined occurrence and areas of periapical bone resorption. Three comparative groups of CBCT radiographs were prepared by average projection of thin slabs with different bucco-lingual thicknesses (0.1, 3.0, and 8.0 mm) using a 3D visualization software. Radiographic densities were compensated by image normalization. Digital images were processed with mathematical morphology operations. The radiographic density and morphological features of periapical lesions were compared among three groups of CBCT in different time points. In the CBCT group with 0.1 mm thickness, radiographic density (p<0.05) and trabecular bone area (p<0.01) were significantly decreased at the fifth week. However, in the CBCT groups with 3 mm and 8 mm thickness and periapical radiographs, none of densitometric and morphological features showed any significant differences in different time points. Radiographic density of periapical lesion showed increasing tendency at the eleventh week after pulp exposure. Radiographic detection of periapical lesions was possible at the fifth week after pulp contamination by quantitative method and was affected by buccolingual bone thickness.

  11. Radiographic anatomy of the thoraco-abdominal cavity of the ostrich (Struthio camelus

    Directory of Open Access Journals (Sweden)

    W.M. Wagner

    2001-07-01

    Full Text Available This study provides a reference for the radiographic anatomy of the thoraco-abdominal cavity of female ostriches as a representative of ratites. One ostrich cadaver, 2 adult and 2 growing ostriches were used. Right lateral radiographs produced by a 6-frame technique and 2 dorsoventral radiographs produced by an adapted 3-frame technique were selected and schematic illustrations of these were labelled to illustrate normal radiographic anatomy. Differences from other avian species and unique features of the ostrich are briefly discussed.

  12. Comparison of the critical shoulder angle in radiographs and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bouaicha, Samy [University of British Columbia, Divison of Arthroscopic, Reconstructive Surgery and Joint Preservation, Department of Orthopaedics, Vancouver (Canada); Zurich University Hospital, Division of Trauma, Zurich (Switzerland); Ehrmann, Christine [University of British Columbia, Department of Radiology, Vancouver (Canada); Slankamenac, Ksenija [Zurich University Hospital, Division of Trauma, Zurich (Switzerland); Regan, William D. [University of British Columbia, Divison of Arthroscopic, Reconstructive Surgery and Joint Preservation, Department of Orthopaedics, Vancouver (Canada); Moor, Beat K. [Insel University Hospital, Department of Orthopaedics, Berne (Switzerland)

    2014-08-15

    The critical shoulder angle (CSA) is an indicator of degenerative shoulder pathologies. CSAs above 35 are associated with degenerative rotator cuff disease, whereas values below 30 are common in osteoarthritis of the glenohumeral joint. Measurements are usually performed on radiographs; however, no data have been reported regarding the reliability of CT scan measurements between different readers or the reproducibility of measurements from radiographs to CT scans. The purpose of our study was to clarify whether CSA measurements on radiographs and CT scans of the same patients show similar values. CSA measurements of 60 shoulders (59 patients) were performed on radiographs and multiplanar reconstructions of corresponding CT scans. Inter-reader reliability and inter-method correlation were calculated. The mean discrepancy between readers was only 0.2 (SD ±1.0 ) on radiographs. CT scan measurements showed a mean discrepancy of 0.3 (SD ±1.2 ). The inter-reader reliability was 0.993 for radiographs and 0.989 for CT scans. There was a very strong inter-method correlation between the CSA measured on radiographs and CT scans (Spearman's rho = 0.974). The mean differences between angles on radiographs and CT measurements were -0.05 (SD ±1.2 ) and 0.1 (SD ±1.2 ), respectively. Measurements of the CSA on anterior-posterior radiographs and CT scans are highly correlated, and inter-modality differences are negligible. (orig.)

  13. Radiographic study of bone changes on TMJ arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1982-11-15

    The author analyzed the morphologic changes of bone structures from 1256 radiographs of 314 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral projection and orthopantomography. The interrelations of the bone changes and clinical symptoms were examined. Also, the positional relationships of condylar head, articular fossa and articular eminence in the mouth open and closed state were observed in the patients with bone changes. The results were as follows; 1. The most frequent bone change in the TMJ arthrosis was eburnation of cortical bone (35.64%) of total cases. Then came bone surface erosion and localized radiolucency (26.18%), marginal proliferation (9.7%) and flattening of articular surface (9.58%) in that order. 2. The most frequent site of bone change was articular eminence (41.70%). The came condylar head (21.09%) and articular fossa (20.73%) in that order. 3. In the patients with bone changes, their clinical symptoms were pain (51.55%), clicking sound during mandibular movement (37.71%) and limited mandibular movement (10.73%). In the patients complaining pain, their radiographs showed eburnation of cortical bone (30.68%), bone surface erosion and localized radiolucency (27.45%) and flattening in the (30.68%), bone surface erosion and localized radiolucency (27.45%) and flattening of articular surface (10.68%). 4. The condylar positional changes in the TMJ arthrosis patients with bone changes were as follows: in the mouth closed state, there were the widening of joint space in 624 cases (50.00%), the narrowing of joint space in 543 cases (43.47%) and bone on bone relationships in 82 cases (6.57%). In the mouth open state, there were forward positioning of the condyle in 332 cases (28.55%), limitation of movement in 332 cases (28.55%), bone on bone relationships in 248 cases (21.31%) and downward positioning of condyle in 217 cases (18.66%). Bone on bone relationships in 248 cases (21.32%) and downward positioning of

  14. Radiographic and HRCT findings of pneumocystis carinii pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jin Sam; Kim, Kun Il; Kim, Chang Won; Park, Soon Kew; Cho, Goon Jae [Pusan National Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-08-01

    To analyze the radiographic and HRCT findings of Pneumocystic carinii pneumonia. We reviewed the medical records and retrospectively analysed the chest radiographs(n=31) and HRCT scans(n=17) of 31 patients with Pneumocystis carinii pneumonia who had been followed up at our institute between, 1993 and March 1998. Pneumocystis carinii pneumonia was confirmed by cytologic evaluation of sputum stained with methenamine silver(n=25) or on the basis of clinical history(n=6). The study group included 17 men and 14 women aged 28-78(average, 53.6) years. Twenty-eight patients had underlying conditions such as hematologic diseases(n=13), AIDS(n=8), malignancy(n=2), DM(n=2) and malnutrition(n=1), and three were free from underlying diseases. Twenty patients had pure Pneumocystis carinii pneumonia and 11 had combined lung diseases, namely pulmonary tuberculosis(n=4), pulmonary metastasis(n=2), bacterial pneumonia(n=2), atypical mycobacterial infection(n=1), pulmonary edema(n=1), and Kaposi' s sarcoma(n=1). Chest radiographic findings of 20 cases of pure Pneumocystis carinii pneumonia included consolidation(n=12), linear-reticular opacity(n=8), ill defined haziness(n=7), and nodules(n=6), with bilaterality in is cases and zonal predominance in ten [central(n=5), lower(n=5)]. Ancillary findings included pleural effusion(n=10), cysts(n=5), lymphadenopathy(n=4) and pneumothorax(n=1). In two patients, findings were entirely normal. HRCT findings in ten cases of pure Pneumocystis carinii pneumonia included ground-glass opacity(n=6), consolidation(n=6), linear-reticular opacity(n=8), and nodules(n=5), with bilaterallity in seven cases and zonal predominance in five [central(n=5), lower(n=2)]. Ancillary findings among these cases included pleural effusion(n=4), lymphadenopathy(n=2), cysts(n=1), and pneumothorax(n=1). HRCT findings in seven cases of Pneumocystis carinii pneumonia combined with other lung diseases included nodules(n=6), ground-glass opacity(n=5), linear

  15. A study on secondary images in panoramic radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Dai Hee; Kim, Han Pyong [Department of Dental Science, Yonsei University, Seoul (Korea, Republic of)

    1984-11-15

    This study was performed to observe the secondary images and to analyse the relationships between the primary and secondary images in panoramic radiograph. Using the Morita's Panex-EC panoramic x-ray machine and the human dry skull, the author analysed 17 radiographs which were selected from 65 radiographs of the dry skull that attached the radiopaque materials, and the attached regions of the radiopaque materials were the normal anatomical structures which were important and selected as a region for the evaluation of the secondary images effectively. The results were as follows; 1. The cervical vertebrae showed three images. The midline image was the most distorted and less clear, and bilateral images were slightly superimposed over the posterior border of the mandibular ramus. 2. In mandible, the secondary image of the posterior border of the ramus was superimposed on the opposite ramus region, and this image was elongated from the anterior border of the ramus to the lateral side of the posterior border of the ramus. The secondary image of the condyle was observed on the upper area of the coronoid process, the sigmoid notch and the condyle in opposite side. 3. In maxilla, the posterior region of the hard palate showed the secondary image on the lower part of the nasal cavity and the medial wall of the maxillary sinus. 4. The primary images of the occipital condyle and the mastoid process appeared on the same region, and only the secondary image of the occipital condyle was observed symmetrically on the opposite side with similar shape to the primary one. 5. In the cranial base, the anatomical structures of the midsagittal portions like a inferior border of the frontal sinus, sella turcica, inferior border of the sphenoid sinus and inferior border of the posterior part of the occipital bone showed the similar shape between the primary and secondary images symmetrically. 6. The petrous portion of the temporal bone showed the secondary image of the lateral side

  16. Clinical, microbiological and radiographic considerations observed around dental implants

    Directory of Open Access Journals (Sweden)

    Fabiana Amaral Chiapinotto

    2012-01-01

    Full Text Available Introduction: Periimplantitis is characterized by the inflammation of the soft tissues, bleeding, and suppuration, as well as rapid bone loss around dental implants that are in function. The lesion is associated with the presence of subgingival plaque, which contains a wide variety of Gram-negative anaerobic microorganisms. Objective: This review aimed to expose some clinical, microbiological and radiographic characteristics found in periodontal tissues and around dental implants. Literature review: Despite the anatomical differences between the periodontium and the tissues around implants, several studies have indicated some similarities, such as the production of inflammatory mediators and active microbiota. Conclusion: Regular maintenance and daily plaque control may be important factors in the long-term maintenance of implant-supported prostheses.

  17. Review on Lossless Image Compression Techniques for Welding Radiographic Images

    Directory of Open Access Journals (Sweden)

    B. Karthikeyan

    2013-01-01

    Full Text Available Recent development in image processing allows us to apply it in different domains. Radiography image of weld joint is one area where image processing techniques can be applied. It can be used to identify the quality of the weld joint. For this the image has to be stored and processed later in the labs. In order to optimize the use of disk space compression is required. The aim of this study is to find a suitable and efficient lossless compression technique for radiographic weld images. Image compression is a technique by which the amount of data required to represent information is reduced. Hence image compression is effectively carried out by removing the redundant data. This study compares different ways of compressing the radiography images using combinations of different lossless compression techniques like RLE, Huffman.

  18. Trabecular architecture analysis in femur radiographic images using fractals.

    Science.gov (United States)

    Udhayakumar, G; Sujatha, C M; Ramakrishnan, S

    2013-04-01

    Trabecular bone is a highly complex anisotropic material that exhibits varying magnitudes of strength in compression and tension. Analysis of the trabecular architectural alteration that manifest as loss of trabecular plates and connection has been shown to yield better estimation of bone strength. In this work, an attempt has been made toward the development of an automated system for investigation of trabecular femur bone architecture using fractal analysis. Conventional radiographic femur bone images recorded using standard protocols are used in this study. The compressive and tensile regions in the images are delineated using preprocessing procedures. The delineated images are analyzed using Higuchi's fractal method to quantify pattern heterogeneity and anisotropy of trabecular bone structure. The results show that the extracted fractal features are distinct for compressive and tensile regions of normal and abnormal human femur bone. As the strength of the bone depends on architectural variation in addition to bone mass, this study seems to be clinically useful.

  19. HADES, A Code for Simulating a Variety of Radiographic Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Aufderheide, M B; Henderson, G; von Wittenau, A; Slone, D M; Barty, A; Martz, Jr., H E

    2004-10-28

    It is often useful to simulate radiographic images in order to optimize imaging trade-offs and to test tomographic techniques. HADES is a code that simulates radiography using ray tracing techniques. Although originally developed to simulate X-Ray transmission radiography, HADES has grown to simulate neutron radiography over a wide range of energy, proton radiography in the 1 MeV to 100 GeV range, and recently phase contrast radiography using X-Rays in the keV energy range. HADES can simulate parallel-ray or cone-beam radiography through a variety of mesh types, as well as through collections of geometric objects. HADES was originally developed for nondestructive evaluation (NDE) applications, but could be a useful tool for simulation of portal imaging, proton therapy imaging, and synchrotron studies of tissue. In this paper we describe HADES' current capabilities and discuss plans for a major revision of the code.

  20. A level crossing enhancement scheme for chest radiograph images.

    Science.gov (United States)

    Nagesha; Kumar, G Hemantha

    2007-10-01

    A new approach for contrast enhancement of chest radiograph image data is presented. Existing methods for image enhancement focus mainly on the properties of the image to be processed while excluding any consideration of the observer characteristics. In several applications, particularly in the medical imaging area, effective contrast enhancement for diagnostic purposes can be achieved by including certain basic human visual properties. In this paper we shall present a novel (recursive) algorithm that tailors the required amount of contrast enhancement based on a combination of the optimal phase representation and the theory of projection onto a convex set. Constraints of maximum bandwidth of the image data, appropriate knowledge of the amplitude value of the image data, heuristic limitations and level crossing measurements serve to impose additional information. So that, the enhanced image data may better converge to the good quality image.