WorldWideScience

Sample records for barium enemaexclamation radiographic

  1. A comparison of radiographer and radiologist reports on radiographer conducted barium enemas

    International Nuclear Information System (INIS)

    Purpose: To compare radiographer and radiologist reports on radiographer conducted barium enemas. Method: Two specially trained, experienced radiographers performed barium enemas and prepared provisional reports without consulting radiologists. Later, formal radiologist reports were issued. The reports of each were compared and correlated with clinical findings derived from case note review. Results:Seven hundred and eighty eight patients had barium enemas. Males numbered 295 (37.5%) and females 493 (62.5%). Patients ages ranged from 17 to 95 years (mean 62). The radiologist reported 244 as normal, 432 as diverticular change, 70 with polyps (31 of which had co-existent diverticular disease), 31 with carcinomas and 12 with colitis (three of which had co-existent diverticular disease). Taking the radiologist reports as gold-standard radiographer reports were concordant in 753 (95.5%). There were 35 (4.5%) discordant radiographer reports of these 19 were false-positive diagnoses of polyps and six false positive diagnoses of diverticular change. There were seven false-negative diagnoses of polyps (only one of these was found to have a polyp at follow-up endoscopy). There was one false-negative diagnosis of colitis and two false-negative reports of diverticular change. On follow up there were no false negative diagnoses of carcinoma by either radiographer or radiologist. There was one concordant false-positive diagnosis of carcinoma. Conclusion:Radiographers with specialized training can report barium enemas to a high standard

  2. Radiographer and radiologist perception error in reporting double contrast barium enemas: A pilot study

    International Nuclear Information System (INIS)

    Purpose: The practice of radiographers performing double contrast barium enemas (DCBE) is now widespread and in many centres the radiographer's opinion is, at least, contributing to a dual reporting system [Bewell J, Chapman AH. Radiographer performed barium enemas - results of a survey to assess progress. Radiography 1996;2:199-205; Leslie A, Virjee JP. Detection of colorectal carcinoma on double contrast barium enema when double reporting is routinely performed: an audit of current practice. Clin Radiol 2001;57:184-7; Culpan DG, Mitchell AJ, Hughes S, Nutman M, Chapman AH. Double contrast barium enema sensitivity: a comparison of studies by radiographers and radiologists. Clin Radiol 2002;57:604-7]. To ensure this change in practice does not lead to an increase in reporting errors, this study aimed to compare the perception abilities of radiographers with those of radiologists. Methods: Three gastro-intestinal (GI) radiographers and three consultant radiologists independently reported on a selection of 50 DCBE examinations, including the level of certainty in their comments for each examination. A blinded comparison of the results with an independent 'standard report' was recorded. Results: The results demonstrate there was no significant difference in perception error for any of the levels of certainty, for single reporting, for double reading by a radiographer/radiologist or by two radiologists. Conclusions: The study shows that radiographers can perceive abnormalities on DCBE at similar sensitivities and specificities as radiologists. While the participants in the study may be typical of a district general hospital, the nature of the study gives it limited external validity. As a pilot, the results demonstrate that, with slight modification, the methodology could be used for a larger study

  3. An evaluation of radiographer performed and interpreted barium swallows and meals

    International Nuclear Information System (INIS)

    Aim: To determine whether radiographers are able to perform and interpret barium swallows and meals (BSM) to an acceptable standard. Materials and methods: A retrospective audit was performed of all radiographer-managed BSMs over a 4-year period in an acute hospital. Descriptive statistics were used to analyse patient demographics, radiation doses, referral sources, and imaging findings. Radiographer reports were compared with radiologist reports assumed to be the reference standard, and correlated with patient outcomes via electronic record searches and case note scrutiny. Reporting accuracy, sensitivity, and specificity were calculated. Results: Three radiographers performed a total of 962 BSMs in the 4-year audit period, including a varied and complex case-mix. Only 13 (0.01%) cases were abandoned due to technical reasons, with all other examinations of diagnostic quality. Although radiation dose levels were initially variable, following the installation of modern fluoroscopy equipment they remained comfortably within the national and regional diagnostic reference levels. Consultant radiologists verified the majority of the radiographer reports, with the most experienced radiographer independently reporting 230 cases (24%). Follow-up of patient outcome was possible in 935 cases. The overall radiographer accuracy based on the 935 cases was 98.9%, sensitivity 98%, and specificity 98.9%. Conclusions: Appropriately trained radiographers are able to perform and interpret BSM examinations to a very high standard.

  4. Barium

    International Nuclear Information System (INIS)

    Present article is devoted to barium content in fluoride. In order to obtain the comprehensive view on barium distribution in fluorite 303 mono mineral fractions of various geologic deposits and ores of Kazakhstan, Uzbekistan, Tajikistan and some geologic deposits of Russia were analyzed. The barium content in fluorite of geologic deposits of various mineralogical and genetic type was defined. The basic statistical estimation of barium distribution in fluorite were evaluated.

  5. Barium Swallow Examination: Radiographer and radiologist compliance to National Diagnostic Reference Levels

    International Nuclear Information System (INIS)

    Objectives: Compliance to the National Diagnostic Reference Levels (NDRLs) ensures the radiation dose to patients is maintained at an acceptable level thereby reducing the element of risk and should not be exceeded wherever possible. The aim of the audit was to determine compliance to NDRLs for Dose Area Product (DAP) and fluoroscopy screening time in patients having Barium Swallow Examinations (BSE) between a specialist radiographer (SR) and radiologists. Methods: 157 BSEs DAP and screening time values were collected retrospectively over a five-month period. 34 specialist radiographer (SR)-led, 65 trainee radiologist (TR)-led and 52 consultant radiologist (CR)-led were included in the analysis. Six were excluded. These values were compared to the NDRL; both by individual and group mean value. Statistical analysis was mean, standard deviation and Mann–Whitney U to assess for significant differences between the operator groups. Results: 129 of 151 BSEs were below the NDRL for either DAP, screening time or both, equating to 85.4% compliance. For the three operator group BSE mean DAP values were 2 and mean screening time values 2) and SR-led produced the highest mean DAP value (5.56 Gycm2). DAP values: no significant difference between SR-led and TR-led (p > 0.05); a significant difference was noted between SR-led and CR-led and TR-led and CR-led (p 0.05) was shown; a significant difference was noted between SR-led and TR-led, and SR-led and CR-led (p < 0.05). Conclusions: This audit shows good compliance with the NDRLs for both DAP and screening time. Differences were demonstrated for both DAP values and screening time between the different operator groups. The highest mean values for both DAP and screening time were produced by examinations performed by the newly introduced specialist radiographer-led service

  6. Hereditary nonpolyposis colorectal cancer: not just a barium enema! Radiographic manifestations and screening tools

    International Nuclear Information System (INIS)

    Hereditary nonpolyposis colorectal cancer (HNPCC) is an autosomal dominant trait characterized by presentation of colorectal cancer (CRC) at an early age and by an increased risk of other primary malignancies, including those of the endometrium. ovaries, stomach, small bowel, upper biliary tract, skin, and brain, as well as by transitional cell carcinoma (TCC) that especially involves the renal pelvis and ureter. Because specific genetic mutations causing HNPCC have been recently discovered, genetic screening options have been developed for some families. Subsequently, radiology has an increasing role in surveillance for and management of these HNPCC-associated tumours. Although colonoscopy is the mainstay of a screening regimen for colon cancer, the barium enema has been a standard radiologic investigation. Further, computed tomography (CT) colonography (now practised in various centres) will, with further refinement, prove to be of increasing value. Ultrasonography is a standard investigation for endometrial and ovarian cancer, with CT and magnetic resonance (MR) imaging often playing a central role. As for TCC, intravenous urography (IVU) had been a standard investigation tool. However, with continued evolution of multidetector row CT with postprocessing manipulation (CT urography [CTU]), the role of IVU is diminishing in most centres. Newfoundland has a high prevalence of HNPCC exhibiting a broad range of manifestations. In this article, radiologic images of various tumours from individuals with HNPCC demonstrate a radiologic spectrum of this fascinating hereditary disease. Screening implications and specific screening methods are reviewed. (author)

  7. Hereditary nonpolyposis colorectal cancer: not just a barium enema{exclamation_point} Radiographic manifestations and screening tools

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.; Jeon, P. [Health Sciences Center, Diagnostic Imaging, St. John' s, Newfoundland (Canada)]. E-mail: u43dlb@mun.ca; Green, J. [Health Sciences Center, Discipline of Genetics, Faculty of Medicine, St. John' s, Newfoundland (Canada)

    2007-10-15

    Hereditary nonpolyposis colorectal cancer (HNPCC) is an autosomal dominant trait characterized by presentation of colorectal cancer (CRC) at an early age and by an increased risk of other primary malignancies, including those of the endometrium. ovaries, stomach, small bowel, upper biliary tract, skin, and brain, as well as by transitional cell carcinoma (TCC) that especially involves the renal pelvis and ureter. Because specific genetic mutations causing HNPCC have been recently discovered, genetic screening options have been developed for some families. Subsequently, radiology has an increasing role in surveillance for and management of these HNPCC-associated tumours. Although colonoscopy is the mainstay of a screening regimen for colon cancer, the barium enema has been a standard radiologic investigation. Further, computed tomography (CT) colonography (now practised in various centres) will, with further refinement, prove to be of increasing value. Ultrasonography is a standard investigation for endometrial and ovarian cancer, with CT and magnetic resonance (MR) imaging often playing a central role. As for TCC, intravenous urography (IVU) had been a standard investigation tool. However, with continued evolution of multidetector row CT with postprocessing manipulation (CT urography [CTU]), the role of IVU is diminishing in most centres. Newfoundland has a high prevalence of HNPCC exhibiting a broad range of manifestations. In this article, radiologic images of various tumours from individuals with HNPCC demonstrate a radiologic spectrum of this fascinating hereditary disease. Screening implications and specific screening methods are reviewed. (author)

  8. Barium enema

    Science.gov (United States)

    Barium enema is a special x-ray of the large intestine, which includes the colon and rectum. ... to a bag that holds a liquid containing barium sulfate. This is a contrast material that highlights ...

  9. Barium Sulfate

    Science.gov (United States)

    Barium sulfate is used to help doctors examine the esophagus (tube that connects the mouth and stomach), ... dimensional pictures of the inside of the body). Barium sulfate is in a class of medications called ...

  10. Atresia coli in a Japanese black calf diagnosed by a barium sulphate enema contrast radiograph in the standing position: a case report

    International Nuclear Information System (INIS)

    A three day-old Japanese black calf was admitted with a history of abdominal distension and absence of defecation. Dilated loops of the small intestine and hypoplasia of the colon and rectum was observed upon a contrast radiographic examination in the standing position. At necropsy atresia coli with undeveloped rectum and patent anal opening was found. We conclude that a contrast radiograph in the standing position is useful for diagnosing atresia coli in such cases

  11. Venous barium embolization, a rare, potentially fatal complication of barium enema: 2 case reports

    International Nuclear Information System (INIS)

    Venous embolization of barium has been recognized for 4 decades as one of the most dreaded complications of barium enema. Fortunately, the condition is extremely rare. In this report, the radiographic findings in 2 cases of venous embolization (one involving the portal vein and one systematic) are described, and ways to decrease the risk of this complication are discussed. (author)

  12. Colonic interposition: radiographic evaluation.

    Science.gov (United States)

    Agha, F P; Orringer, M B

    1984-04-01

    This report reviews the clinical and radiographic features of 40 patients who underwent visceral esophageal substitution with colon for benign or malignant lesions of the esophagus. The incidence and radiographic identification of complications are discussed. All patients were routinely examined with barium esophagrams on postoperative day 10. If an anastomotic leak was suspected clinically before this time, studies were performed using water-soluble iodinated contrast material. Follow-up barium esophagrams were obtained 1-96 months after operation (average, 60 months) in 24 patients. Eight patients (21%) demonstrated asymptomatic "jejunization" of the colonic mucosa with no attributable clinical manifestations; this finding resolved in 1-3 months, without sequelae, and has not been reported before. The spectrum of ischemic changes in the colonic segment included mucosal edema, spasm, ulceration, loss of haustration, and frank necrosis. Radiographically detectable early postoperative complications included anastomotic leak in six (three pharyngocolic, three cervical esophagocolic) and aspiration of barium into the tracheobronchial tree due to incoordinated swallowing in eight. Late postoperative complications included anastomotic narrowing (12) malfunctioning of the colon due to impaired emptying (five), recurrent aspiration pneumonia (three), small bowel obstruction (three), transhiatal herniation of small bowel through the diaphragmatic hiatus (one), and reflux into the retained bypassed esophagus (one). PMID:6608225

  13. Barium Sulfate

    Science.gov (United States)

    ... using x-rays or computed tomography (CAT scan, CT scan; a type of body scan that uses ... be clearly seen by x-ray examination or CT scan. ... more times before an x-ray examination or CT scan.If you are using a barium sulfate ...

  14. BARIUM RECOVERY PROCESS

    Science.gov (United States)

    Blanco, R.E.

    1959-07-21

    A method of separating barium from nuclear fission products is described. In accordance with the invention, barium may be recovered from an acidic solution of neutron-irradiated fissionable material by carrying ihe barium cut of solution as a sulfate with lead as a carrier and then dissolving the barium-containing precipitate in an aqueous solution of an aliphatic diamine chelating reagent. The barium values together with certain other metallic values present in the diamine solution are then absorbed onto a cation exchange resin and the barium is selectively eluted from the resin bed with concentrated nitric acid.

  15. Radiographical evaluation of ulcerative colitis

    OpenAIRE

    Deepak, Parakkal; Bruining, David H.

    2014-01-01

    Radiographical modalities have become important diagnostic tools in cases of ulcerative colitis (UC). Imaging can be used non-invasively to determine the extent of involvement, severity of disease and to detect disease-related complications and extra-intestinal inflammatory bowel disease (IBD) manifestations. While abdominal X-rays and barium enemas still retain their relevance in specific clinical settings, the use of computed tomography enterography (CTE) or magnetic resonance enterography ...

  16. Barium enema (image)

    Science.gov (United States)

    A barium enema is performed to examine the walls of the colon. During the procedure, a well lubricated enema tube is inserted gently into the rectum. The barium, a radiopaque (shows up on X-ray) contrast ...

  17. Radiation dose in mass screening for gastric cancer with high-concentration barium sulphate compared with moderate-concentration barium sulphate

    International Nuclear Information System (INIS)

    Full text: Recently, high-concentration barium sulfate has been developed and is used in many medical facilities. This study compared radiation dose using high-concentration and moderate-concentration barium sulfate. The dose was evaluated with an experimental method using a gastric phantom and with a clinical examination. In the former, the dose and X-ray tube load were measured on the phantom with two concentrations of barium sulfate. In the latter, the fluoroscopic dose-area product (DAP), the radiographic DAP and their sum, the total DAP, were investigated in 150 subjects (112 males, 38 females) treated with both concentrations of barium sulfate. The effective dose was calculated by the software of PCXMC in every case. The results of the experimental evaluation indicated that the effective dose and X-ray tube load were greater with high-concentration barium sulfate than with moderate-concentration barium sulfate (p < 0.05). The results of the clinical evaluation indicated that the fluoroscopic DAP was greater with moderate-concentration barium sulfate than with high-concentration barium sulfate (p < 0.05), but the radiographic DAP was quite the reverse, so the total DAP and effective dose were almost same with both concentrations of barium sulfate. We conclude that high-concentration barium sulfate does not increase radiation dose in mass screening for gastric cancer.

  18. Radioisotope analyzer of barium

    International Nuclear Information System (INIS)

    Principle of operation and construction of radioisotope barium sulphate analyzer type MZB-2 for fast determination of barium sulphate content in barite ores and enrichment products are described. The gauge equipped with Am-241 and a scintillation detector enables measurement of barium sulphate content in prepared samples of barite ores in the range 60% - 100% with the accuracy of 1%. The gauge is used in laboratories of barite mine and ore processing plant. 2 refs., 2 figs., 1 tab. (author)

  19. Adult Hirschprung disease: radiographic findings.

    Science.gov (United States)

    Mindelzun, R E; Hicks, S M

    1986-09-01

    Hirschprung disease is usually diagnosed in infancy. Occasionally patients reach adulthood without diagnosis or treatment. Four cases of adult Hirschprung disease are described. The principal radiographic findings are a markedly dilated, feces-filled colon above the zone of transition; a narrowed rectum; a cone- or funnel-shaped zone of transition; and a mosaic colonic pattern caused by collapsed redundant mucosa after colonic cleansing. In an adult, identification on a barium enema examination of an abrupt, smooth transition zone in the rectum with proximal colonic dilatation, in conjunction with an appropriate clinical history, should suggest the diagnosis of adult Hirschprung disease. PMID:3737900

  20. Use of the barium enema in the diagnosis of necrotizing enterocolitis

    Energy Technology Data Exchange (ETDEWEB)

    Uken, P.; Smith, W.; Franken, E.A.; Frey, E.; Sato, Y.; Ellerbroek, C.

    1988-01-01

    Necrotizing enterocolitis (NEC) is associated with considerable morbidity and mortality in infants. The diagnosis relies heavily upon radiographic and clinical features. Failure to accurately diagnose NEC is associated with a risk of complications and death, however overdiagnosis also causes both morbidity and mortality as well as excessive medical costs. This report documents the use of barium enema to evaluate suspected clinical or radiographic NEC in 31 premature infants with ambiguous clinical and radiographic signs. The enema was normal in 26 infants and no treatment for NEC was given. Only one of these infants developed signs of NEC subsequent to the examination. Five infants had radiographic evidence of colitis including small ulcerations, spasm, intramural extravasation of barium and mucosal irregularity. Two of the five positive cases are pathologically documented. The barium enema can represent a significant improvement in the specificity of the diagnosis of NEC. Its greatest value is in the exclusion of NEC in ambiguous cases.

  1. Radiographic quality

    International Nuclear Information System (INIS)

    The control and evaluation of radiographic quality vary considerably from institution to institution, and this has resulted in increased government legislation in most jurisdictions, which attempts to provide some measure of uniformity in standards of equipment installation, maintenance, and use. Where legislation is not yet in place, it is pending, so that all facilities using x-radiation are, or soon will be, legally bound to operate within accepted guidelines. These guidelines are established to provide the radiologist with radiographs of optimum diagnostic quality while keeping the radiation dose to the patient and radiology personnel as low as possible. There are many excellent publications that provide detailed step-by-step instructions on each facet of radiographic quality control these procedures will, therefore, not be covered in detail here. The following information may, however, be of interest as it relates primarily to pediatric radiography and will prove useful to those initiating quality control and evaluation programs

  2. Radiographic artifacts

    International Nuclear Information System (INIS)

    Since the early days of radiology, artifacts have appeared on radiographs. Actually, the first radiograph ever taken had an artifact present, a metallic ring on the patient's hand. Artifacts are a common cause of repeat radiographs; they often occur in unexpected places, with many peculiar internal objects being detected. Without a complete history many unusual artifactual shadows cannot be adequately identified. This chapter is presented in ''atlas'' format, using a pictorial review of various artifacts. Few radiological interpretation texts show any artifacts, despite their common occurrence. This provided the impetus to add this atlas to the book. In order to avoid the production of these artifacts, close attention to patient preparation and positioning and good darkroom procedures are necessary. The use of up-to-date, good quality x-ray equipment is also very helpful

  3. Radiographic spectrum of rectocolonic calcification from schistosomiasis.

    Science.gov (United States)

    Fataar, S; Bassiony, H; Hamed, M S; Ghoneim, I; Satyanath, S; Hebbar, H G; Elgindy, N N; Hanna, R M

    1984-05-01

    Rectocolonic calcification was detected radiographically in 17 sites in 14 patients undergoing excretory urography for the assessment of urinary schistosomiasis. The right colon was involved in 11 sites, the rectum in four, and the left colon in two. The pattern of calcification varied according to the degree of bowel distension. A laminar pattern was common to all sites and occurred when the rectum or colon was distended with air, feces, or barium. A laminar or irregular amorphous density was found in the empty colon, whereas the calcified, empty rectum had a corrugated pattern. Rectocolonic calcification is probably the most common radiographic manifestation of schistosomal infestation of the gastrointestinal tract. PMID:6609576

  4. Tailored Barium Swallow Study

    Science.gov (United States)

    ... View Denver Pollen Count You are here: Programs & Services > Tests We Offer > Imaging Tests Tailored Barium Swallow Study The TBS is a special study that is completed in radiology. The test evaluates the mouth and the throat ...

  5. Radiographic apparatus

    International Nuclear Information System (INIS)

    In this disclosure, a radiographic method is described by which a decrease in the duration of exposure to (X-)radiation is obtained. In this way a greater accuracy can be achieved. A multiple detector system is applied in the present set-up. The method is compared to existing techniques

  6. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A;

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital.......To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  7. Lower GI Series (Barium Enema)

    Science.gov (United States)

    ... barium into a bedpan or nearby toilet. A health care professional may give you an enema to flush out the rest of the barium. An x-ray technician and a radiologist perform a lower gastrointestinal (GI) series at a ...

  8. Observed Barium Emission Rates

    Science.gov (United States)

    Stenbaek-Nielsen, H. C.; Wescott, E. M.; Hallinan, T. J.

    1993-01-01

    The barium releases from the CRRES satellite have provided an opportunity for verifying theoretically calculated barium ion and neutral emission rates. Spectra of the five Caribbean releases in the summer of 1991 were taken with a spectrograph on board a U.S. Air Force jet aircraft. Because the line of sight release densities are not known, only relative rates could be obtained. The observed relative rates agree well with the theoretically calculated rates and, together with other observations, confirm the earlier detailed theoretical emission rates. The calculated emission rates can thus with good accuracy be used with photometric observations. It has been postulated that charge exchange between neutral barium and oxygen ions represents a significant source for ionization. If so. it should be associated with emissions at 4957.15 A and 5013.00 A, but these emissions were not detected.

  9. Radiographic element

    International Nuclear Information System (INIS)

    Radiographic elements are disclosed comprised of first and second silver halide emulsion layers separated by an interposed support capable of transmitting radiation to which the second image portion is responsive. At least the first imaging portion contains a silver halide emulsion in which thin tubular silver halide grains of intermediate aspect ratios (from 5:1 to 8:1) are present. Spectral sensitizing dye is adsorbed to the surface of the tubular grains. Increased photographic speeds can be realized at comparable levels of crossover. (author)

  10. Radiographic element

    International Nuclear Information System (INIS)

    Radiographic elements are disclosed having first and second silver halide emulsion layers comprised of a dispersing medium and radiation-sensitive silver halide grains, and a support interposed between said silver halide emulsion layers capable of transmitting radiation to which said second silver halide emulsion layer is responsive. These elements are characterized in that at least said first silver halide emulsion layer contains tabular silver halide grains and spectral sensitizing dye adsorbed to the surface of the grains. Crossover can be improved in relation to the imaging characteristics. (author)

  11. Radiographic system

    International Nuclear Information System (INIS)

    This invention discloses a radiographic system comprising an X-ray source disposed to direct an X-ray beam through an adjustable shutter aperture in an aligned collimator and onto an image receptor in a holder located at a preselected distance from the source; and automatic means for preventing an X-ray exposure until prescribed operating conditions have been satisfied, the automatic means including a readily interchangeable read-only-memory module for storing the prescribed conditions therein and ascertaining whether or not the prescribed conditions have been met

  12. Radiographic gastrointestinal anatomy of the foal

    International Nuclear Information System (INIS)

    The purposes of this study were to evaluate a technique for contrast gastrointestinal (GI) radiography and to define the normal radiographic anatomy of the foal GI tract as demonstrated by survey and contrast radiography. GI studies were performed in five normal foals. Right lateral standing, right and left lateral recumbent, and ventrodorsal (dorsal recumbent) radiographs were evaluated. The recumbent lateral and ventrodorsal positions were preferred, although the right lateral standing position demonstrated most structures. Radiographic positions that clearly identified a specific GI region were determined. The dosage of contrast medium used (5 ml/kg of a 30% wt/vol barium suspension) was adequate to outline the GI tract. Transit times allowed evaluation of the large colon within eight hours

  13. New barium tantalum sulphides

    International Nuclear Information System (INIS)

    The authors discuss a new barium tantalum sulphide, Ba3Ta2S8, prepared by sulphurization of a mixture of BaCO3 and Ta2O5. The electron and powder X-ray diffraction patterns of the compound are indexed on the basis of a monoclinic cell with lattice constants. A structure model is proposed. The refinement based on the powder X-ray diffraction intensities is performed

  14. Barium calcium hydroxyapatite solid solutions

    International Nuclear Information System (INIS)

    The replacement of calcium by barium in the hydroxyapatite structure by solid-state reaction at different temperatures and by precipitation from an aqueous system has been investigated by X-ray diffraction and i.r. absorption analyses. The products obtained by solid-state reaction at 1200 deg C are solid solutions over the range of barium concentration 60 to 100 atom %. The lattice dimensions and the i.r. frequencies of the solid solutions vary linearly with the atom % of barium. Only small amounts of barium can be incorporated in hydroxyapatite by precipitation from the aqueous system. (author)

  15. Barium sulphate preparations for use in double contrast examination of the upper gastrointestinal tract

    International Nuclear Information System (INIS)

    Physical properties relevant to upper gastrointestinal radiology have been compared for five barium sulphate preparations and related to radiographic results. Evaluation of particles (size and stability) and whole suspension (dispersibility and fluidity) resulted in ranking of the preparations generally in accord with that based on radiological experience in double contrast examinations of the stomach. Experiments with extirpated pig stomach revealed a tendency for large particles in a low viscosity barium sulphate suspension to settle in mucosal grooves. This is believed to contribute to good radiographic definition of both the areae gastricae and small lesions. Particle size is therefore important and susceptibility to flocculation, a possible cause of random change in size during use, was assessed by measuring particle electrophoretic mobility under varying conditions; quantitative differences in suspension flow and dispersibility were also demonstrated. Fluidity and dispersibility together with rapid sedimentation of suitably sized particles resistant to flocculation underlie the successful use of low viscosity high density barium sulphate suspensions. (U.K.)

  16. Upper gastrointestinal examinations: a radiographic study of clinically normal Beagle puppies

    International Nuclear Information System (INIS)

    A total of 24 upper gastrointestinal examinations were performed on four weanling beagle puppies over six weeks, using liquid barium (10 ml/kg body weight of 60 per cent w/v barium sulphate suspension] and barium food (8 g/kg of crushed kibble dog food and 7 ml/kg body weight of 60 per cent w/v barium sulphate suspension) as contrast media. The radiographic appearance was similar to that noted in adult dogs except for the consistent location of the pylorus on or near the midline. Duodenal pseudoulcers were seen more often with liquid barium and the caecal shadows were identified more often with the longer examination time with barium food. The stomach of the puppies appeared to have discriminatory emptying function; that is, semi-solid food was emptied from the stomach at a slower rate (210 to 450 minutes) than liquid (60 to 90 minutes). Solid meals emptied faster in puppies than in adult dogs. Dosages of 13 to 15 mg/kg body weight for the liquid barium examination and 14 g of ground kibble and 16 ml of barium sulphate suspension per m2 of body surface area for the barium food examination are suggested as more appropriate for contrast studies in puppies

  17. Barium zirconate base ceramics

    International Nuclear Information System (INIS)

    The chemical corrosion at high temperatures is a serious problem in the refractory materials field, leading to degradation and bath contamination by elements of the refractory. The main objective of this work was to search for ceramics that could present higher resistance to chemical attack by aggressive molten oxides. The general behaviour of a ceramic material based on barium zirconate (Ba Zr O3) with the addition of different amounts of liquid phase former was investigated. The densification behaviour occurred during different heat treatments, as well as the microstructure development, as a function of the additives and their reactions with the main phase, were observed and are discussed. (author)

  18. Radiographic morphometry of alveoli and small pulmonary arteries

    International Nuclear Information System (INIS)

    This paper reports on quantitative analysis of radiographic fine structure of the lung which is an approach used to get functional information from anatomic data (e.g., a correlation of alveolar surface area, membrane thickness, and vessel density to diffusion capacity). More than 250 lung specimens were inflated and fixed with hot formalin vapor with use of an apparatus resembling a simplified Engstrom respirator. Radiographs were obtained of 1-cm sections of the fixed lungs in mammography technique. Pulmonary segmental arteries were filled before fixation with barium sulfate. Computer-assisted morphometry was performed on healthy and diseased lungs

  19. MR Colonography with fecal tagging: Barium vs. barium ferumoxsil

    DEFF Research Database (Denmark)

    Achiam, M.P.; Chabanova, E.; Logager, V.B.; Thomsen, H.S.; Rosenberg, J.

    2008-01-01

    . Materials and Methods. Twenty patients referred to CC underwent dark lumen MRC prior to the colonoscopy. Two groups of patients received two different oral contrast agents (barium sulfate and barium sulfate/ferumoxsil) as a laxative-free fecal tagging prior to the MRC. After MRC, the contrast agent was...... rated qualitatively (with the standard method using contrast-to-wall ratio) and subjectively (using a visual analog scale [VAS]) by three different blinded observers. Results. Evaluated both qualitatively and subjectively, the tagging efficiency of barium sulfate/ferumoxsil was significantly better (P...... <.05) than barium sulfate alone. The VAS method for evaluating the tagging efficiency of contrast agents showed a high correlation (observer 11, r = 0.91) to the standard method using contrast-to-wall ratio and also a high interclass correlation (observer 11 and III = 0.89/0.85). MRC found I of 22 (5...

  20. Doped barium titanate nanoparticles

    Indian Academy of Sciences (India)

    T K Kundu; A Jana; P Barik

    2008-06-01

    We have synthesized nickel (Ni) and iron (Fe) ion doped BaTiO3 nanoparticles through a chemical route using polyvinyl alcohol (PVA). The concentration of dopant varies from 0 to 2 mole% in the specimens. The results from X-ray diffractograms and transmission electron micrographs show that the particle diameters in the specimen lie in the range 24–40 nm. It is seen that the dielectric permittivity in doped specimens is enhanced by an order of magnitude compared to undoped barium titanate ceramics. The dielectric permittivity shows maxima at 0.3 mole% doping of Fe ion and 0.6 mole% of Ni ion. The unusual dielectric behaviour of the specimens is explained in terms of the change in crystalline structure of the specimens.

  1. New barium tantalum sulphides

    International Nuclear Information System (INIS)

    A new barium tantalum sulphide has been synthesized by the reaction of CS2 with a mixture of BaCO3 and Ta2O5. The chemical analysis of the compound was performed for 3 components (Ba, Ta and S), and the chemical composition was found to be BaTa2S5. The powder X-ray diffraction peaks were indexable on the basis of a hexagonal cell with lattices constants of a=3.32A, c=25.13A. However, the electron diffraction measurements show that the structure is more complex than that observed by powder X-ray diffraction. The compound indicates metallic behavior and Pauli paramagnetism

  2. Radiographic Assessment for Back Pain

    Science.gov (United States)

    Radiographic Assessment for Back Pain What are Radiographic Assessments? When Should I get an X-ray for Low Back ... How Effective are X-rays? What are Radiographic Assessments? Radiographic assessments for low back pain involve the ...

  3. Abundance analysis of barium and mild barium stars

    CERN Document Server

    Smiljanic, R; Silva, L

    2007-01-01

    High signal to noise, high resolution spectra were obtained for a sample of normal, mild barium, and barium giants. Atmospheric parameters were determined from the FeI and FeII lines. Abundances for Na, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Sr, Y, Zr, Ba, La, Ce, Nd, Sm, Eu, and Gd, were determined from equivalent widths and model atmospheres in a differential analysis, with the red giant Eps Vir as the standard star. The different levels of s-process overabundances of barium and mild barium stars were earlier suggested to be related to the stellar metallicity. Contrary to this suggestion, we found in this work no evidence for barium and mild barium to have a different range in metallicity. However, comparing the ratio of abundances of heavy to light s-process elements, we found some evidence that they do not share the same neutron exposure parameter. The exact mechanism controlling this difference is still not clear. As a by-product of this analysis we identify two normal red giants misclass...

  4. Barium aluminate cement: its application

    International Nuclear Information System (INIS)

    The technology of manufacturing barium aluminate cement from barium sulfate and alumina, using a rotary kiln for firing the clinker is described. The method of granulation of the homogenized charge was used. Conditions of using the ''to mud'' method in industry were indicated. The physical and chemical properties of barium aluminate cement are determined and the quality of several batches of cement prepared on a semi-industrial scale and their suitability for making highly refractory concretes are tested. The optimal composition of the concretes is determined as a function of the mixing water and barium aluminate cement contents. Several experimental batches of concretes were used in the linings of furnaces in the steel industry. The suitability of these cements for use in fields other than steelmaking is examined. It is established that calcium aluminate cement has certain limited applications

  5. Discovery of the Barium Isotopes

    OpenAIRE

    SHORE, A.; A. Fritsch; Ginepro, J. Q.; Heim, M.; Schuh, A.; Thoennessen, M

    2009-01-01

    Thirty-eight barium isotopes have so far been observed; the discovery of these isotopes is discussed. For each isotope a brief summary of the first refereed publication, including the production and identification method, is presented.

  6. Barium light source method and apparatus

    Science.gov (United States)

    Curry, John J. (Inventor); MacDonagh-Dumler, Jeffrey (Inventor); Anderson, Heidi M. (Inventor); Lawler, James E. (Inventor)

    2002-01-01

    Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

  7. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough

    Directory of Open Access Journals (Sweden)

    Carlos Shuler Nin

    2013-12-01

    Full Text Available OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough.METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons.RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6% of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6% of the patients, whereas the treatment was ineffective in 1 (8.4%. We observed no complications related to barium swallow, such as contrast aspiration.CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  8. Fast radiographic systems

    International Nuclear Information System (INIS)

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  9. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  10. Intussusception: Clinical and radiographic factors influencing reducibility

    International Nuclear Information System (INIS)

    Hydrostatic reduction of intussusception by barium or air enema has been widely accepted. The five-year experience with this procedure at two children's hospitals is reviewed and the results compared to previous studies. Various clinical and radiographic factors are evaluated in relation to the reduction rate. The findings show that the more distal the intussusception is encountered, the lower the rate of reduction. However, 25% are reduced within the rectum with no evidence of increased complications. Small bowel obstruction and prolonged durations of signs and symptoms decreased the rate of reduction statistically but there is no significant increase in complication rate in those attempted, contrary to a previous report. The crescent sign (dissection sign) and age of the patient are not significant factors in reduction as reported by other studies. (orig.)

  11. An 8-year review of barium studies in the diagnosis of gastroparesis

    International Nuclear Information System (INIS)

    Aim: To determine the utility of barium studies for diagnosing gastroparesis in patients with nausea, vomiting, or other related symptoms. Materials and methods: Radiology files revealed gastroparesis without gastric outlet obstruction on upper gastrointestinal tract barium studies in 50 patients with nausea, vomiting, and other related symptoms. Original reports and images were reviewed to determine whether gastric peristalsis was decreased/absent and to investigate gastric dilatation, fluid or debris, and delayed emptying of barium. Twenty patients (40%) had nuclear gastric emptying studies. Medical records were reviewed to determine the presentation, treatment, and course. The diagnosis of gastroparesis was considered accurate if patients with gastroparesis on barium studies responded to treatment. Results: Forty-six patients (92%) had predisposing factors for gastroparesis, including narcotics and diabetes. Forty-five patients (90%) presented with nausea or vomiting, and 40 patients (80%) had one or more other symptoms, including bloating, early satiety, postprandial fullness, and abdominal pain. Barium studies revealed decreased gastric peristalsis in 46 (92%) of the 50 patients and absent peristalsis in four (8%); 46 patients (92%) had additional findings, including gastric dilatation in 30 (60%), delayed emptying of barium in 27 (54%), debris in 28 (56%; bezoars in three), and retained fluid in 13 (26%). Thirteen (65%) of 20 patients with nuclear gastric emptying studies had delayed emptying of solids and seven (35%) had normal emptying. Thirty-five (83%) of 42 patients treated for gastroparesis had symptomatic improvement versus two (25%) of eight patients not treated. Conclusion: Patients with nausea, vomiting, or other related symptoms who have gastroparesis without gastric outlet obstruction on barium studies can be treated for this condition on the basis of the clinical and radiographic findings

  12. An 8-year review of barium studies in the diagnosis of gastroparesis

    Energy Technology Data Exchange (ETDEWEB)

    Levin, A.A. [Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, PA (United States); Levine, M.S. [Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, PA (United States)], E-mail: marc.levine@uphs.upenn.edu; Rubesin, S.E.; Laufer, I. [Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, PA (United States)

    2008-04-15

    Aim: To determine the utility of barium studies for diagnosing gastroparesis in patients with nausea, vomiting, or other related symptoms. Materials and methods: Radiology files revealed gastroparesis without gastric outlet obstruction on upper gastrointestinal tract barium studies in 50 patients with nausea, vomiting, and other related symptoms. Original reports and images were reviewed to determine whether gastric peristalsis was decreased/absent and to investigate gastric dilatation, fluid or debris, and delayed emptying of barium. Twenty patients (40%) had nuclear gastric emptying studies. Medical records were reviewed to determine the presentation, treatment, and course. The diagnosis of gastroparesis was considered accurate if patients with gastroparesis on barium studies responded to treatment. Results: Forty-six patients (92%) had predisposing factors for gastroparesis, including narcotics and diabetes. Forty-five patients (90%) presented with nausea or vomiting, and 40 patients (80%) had one or more other symptoms, including bloating, early satiety, postprandial fullness, and abdominal pain. Barium studies revealed decreased gastric peristalsis in 46 (92%) of the 50 patients and absent peristalsis in four (8%); 46 patients (92%) had additional findings, including gastric dilatation in 30 (60%), delayed emptying of barium in 27 (54%), debris in 28 (56%; bezoars in three), and retained fluid in 13 (26%). Thirteen (65%) of 20 patients with nuclear gastric emptying studies had delayed emptying of solids and seven (35%) had normal emptying. Thirty-five (83%) of 42 patients treated for gastroparesis had symptomatic improvement versus two (25%) of eight patients not treated. Conclusion: Patients with nausea, vomiting, or other related symptoms who have gastroparesis without gastric outlet obstruction on barium studies can be treated for this condition on the basis of the clinical and radiographic findings.

  13. Qualification of Radiographic Technique

    International Nuclear Information System (INIS)

    This paper present some experience from qualification of a radiographic system, according to the Swedish code. The Swedish code, concerning qualification, follows the ENIQ procedure allowing a mix of technical justification and practical tests. The radiographic system, aimed for qualification, is a digital system using an enhanced type of x-ray camera (designed by SAQ Kontroll) and capable to detect IGSCC cracks, 5 mm deep in 60 mm trough wall. Like many others, the Swedish qualification praxis is based on experience from ultrasonic technique. There is also, for radiographic technique, demands with no relevance for digital technique i.e. for film density

  14. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  15. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  16. Interobserver variation in the radiographic diagnosis of gastric ulcer

    International Nuclear Information System (INIS)

    A total of 156 double contrast barium examinations were independently interpreted by two observers for the presence of gastric ulcer. The observed agreement between the two readings was 93%, and after adjusting for the expected chance agreement a kappa value of 0.73 was obtained. At the first reading 4 ulcers, and at the second reading 8 ulcers were interpreted as malignant. None of these interpretations agreed. In a questionnaire study it was demonstrated that gastroenterologists had a realistic impression of the level of agreement in the radiographic detection of gastric ulcer. (orig.)

  17. The problem of the barium stars

    Science.gov (United States)

    Bohm-Vitense, E.; Nemec, J.; Proffitt, C.

    1984-01-01

    Ultraviolet observations of barium stars and other cool stars with peculiar element abundances are reported. Those observations attempted to find hot white dwarf companions. Among six real barium stars studied, only Zeta Cap was found to have a white dwarf companion. Among seven mild, or marginal, barium stars studied, at least three were found to have hot subluminous companions. It is likely that all of them have white dwarf companions.

  18. Radioisotope barium sulphate gauge MZB-2

    International Nuclear Information System (INIS)

    A method and the gauge for measuring content of barium sulphate are described. The gauge is intended for fast determination of barium sulphate in barite ore and in output products of the enrichment process. The measuring range 60-100% of BaSO4, accuracy ±1% and measuring time 60 s were reached. The barium sulphate gauge is used in barite mine ''Boguszow'' in Poland. (author)

  19. Bronchography in dogs. Comparative study with two barium sulphate solutions

    International Nuclear Information System (INIS)

    Two solutions of barium sulphate, 60 and 30% w/v, were compared with the ''overflow'' Bronchographic method. Two groups of eight healthy adult does of both sexes, weighing 7 to 18 kg were used for the study. The dogs were anaesthetised with thiopentone sodium 2% (20 mg/kg iv). After intubation, each dog received contrast medium by a catheter connected to a syringe, in a 9 mi dose. Two series of two x-rays plates were taken in left lateral recumbent, 3 and 6 min after administering the contrast medium and in ventrodorsal projection, 30 sec. later. The x-ray plates obtained were analysed and compared intra and inter group considering the advance speed of the contrast medium, the radiographic density and outlines. Adverse reactions were controlled

  20. ONE CASE REPORT OF ACUTE POISONING BY BARIUM CARBONATE

    Institute of Scientific and Technical Information of China (English)

    GE Qin-min; BIAN Fan; WANG Shu-yun; SHEN Sheng-hui

    2009-01-01

    @@ Most barium poisoning cases were caused by oral intake by mistake. Recent years, barium carbonate poisoning has been rare to be reported. Here we reported a case of acute barium carbonate toxication taken orally on purpose.

  1. Barium Depletion in Hollow Cathode Emitters

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2009-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the ow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  2. Processing science of barium titanate

    Science.gov (United States)

    Aygun, Seymen Murat

    Barium titanate and barium strontium titanate thin films were deposited on base metal foils via chemical solution deposition and radio frequency magnetron sputtering. The films were processed at elevated temperatures for densification and crystallization. Two unifying research goals underpin all experiments: (1) To improve our fundamental understanding of complex oxide processing science, and (2) to translate those improvements into materials with superior structural and electrical properties. The relationships linking dielectric response, grain size, and thermal budget for sputtered barium strontium titanate were illustrated. (Ba 0.6Sr0.4)TiO3 films were sputtered on nickel foils at temperatures ranging between 100-400°C. After the top electrode deposition, the films were co-fired at 900°C for densification and crystallization. The dielectric properties were observed to improve with increasing sputter temperature reaching a permittivity of 1800, a tunability of 10:1, and a loss tangent of less than 0.015 for the sample sputtered at 400°C. The data can be understood using a brick wall model incorporating a high permittivity grain interior with low permittivity grain boundary. However, this high permittivity value was achieved at a grain size of 80 nm, which is typically associated with strong suppression of the dielectric response. These results clearly show that conventional models that parameterize permittivity with crystal diameter or film thickness alone are insufficiently sophisticated. Better models are needed that incorporate the influence of microstructure and crystal structure. This thesis next explores the ability to tune microstructure and properties of chemically solution deposited BaTiO3 thin films by modulation of heat treatment thermal profiles and firing atmosphere composition. Barium titanate films were deposited on copper foils using hybrid-chelate chemistries. An in-situ gas analysis process was developed to probe the organic removal and the

  3. Barium methylphosphonates: synthesis, characterization and mutual interconversions

    Czech Academy of Sciences Publication Activity Database

    Beneš, L.; Melánová, Klára; Svoboda, Jan; Zima, Vítězslav

    Strasbourg: University of Strasbourg, Francie, 2015. P64. [ISIC18 International Symposium on Intercalation Compounds. 31.05.2015-04.06.2015, Strasbourg] R&D Projects: GA ČR(CZ) GA14-13368S Institutional support: RVO:61389013 Keywords : hydrates of barium methylphosphonate * barium hydrogen methylphosphonate * powder X-ray diffraction Subject RIV: CA - Inorganic Chemistry

  4. Nonionic radiographic contrast media

    International Nuclear Information System (INIS)

    The invention deals with nonionic radiographic contrast media. The new media, which are water soluble and have desirable low osmolality properties, are derivates of the 5-amino-2,4,6-triiodine-1,3-benzenecarboxylic acid-unity where the 5-aminonitrogen atom is a part of a 4-, 5- or 6-membered heterocyclic ring

  5. Radiographic study of the hepatomegaly

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Soo [Busan National University College of Medicine, Pusan (Korea, Republic of)

    1980-06-15

    The author studied, with emphasis on the various radiographic projections, the 99 cases of liver enlargement, which underwent the barium meal upper gastrointestinal examinations for the purpose of pursuit of significance of liver enlargement and, at the same time were confirmed by other clinical and pathological methods at Busan National University Hospital for about 2 years from November 1977 to September 1979. The following results were obtained: 1. The incidence of liver enlargement was 63.3% (62 cases) in the 5th decade, which was most prevalent, 18.2% (18 cases) in the 3rd decade, 15.2% (15 cases) in the group over 60, and 3.0% (3 cases) in the age group below 20. Male to female sex ratio was 2 : 1. 2. The causes of the liver enlargement confirmed by the final diagnosis are as follows: Primary hepatic cancer 39 cases (39.3%), liver cirrhosis 30 cases (30.3%), chronic hepatitis 12 cases (12.1%), cancer of the biliary tract 6 cases (6.1%), hepatic fluke 6 cases (6.1%), metastatic tumors 3 cases (3.0%), and hepatic congestion 3 cases (3.0%) 3. In the prone view, the displacement of the duodenal bulb appeared in 18 cases (18.2%). 4. In the routine radiographs, the displacement of the stomach to the left and the pressure indentation of the lesser curvature were noted in 69 cases (69.7%) out of 99 cases. 5.In the left lateral recumbent view, the pressure indentation of the anterior border of the gastric body was seen in 96 cases (97.0%) among the 99 cases, the straightening in 30 cases (27.3%), the marked depression in 30 cases (30.3%), the moderate in 27 cases (27.3%), the minimal in 9 cases (9.1%). 6. Comparing the incidences of the roentgen findings of the liver enlargement in the various projections respectively, the displacement of the duodenal bulb was noted in 18 cases (18.3%) in the prone position. The erect position revealed the displacement of the stomach to the left and the pressure indentation in 57 cases (57.6%), the prone position in 51 cases (51

  6. Barium enema carried out by digital luminescent radiography (DLR) and conventional screen-film system combinations

    International Nuclear Information System (INIS)

    120 double-contrast barium enemas were obtained by both digital luminescent radiography (DLR) and conventional screen-film systems, the digital exposure dose being 50% of the conventional one. In DLR two differently post processed images were obtained from one X-ray exposure: a display with low spatial frequency enhancement was processed to look like a conventional radiograph and was complemented by a display with high spatial frequency enhancement. Analysing the results statistically DLR proved to be diagnostically equivalent to conventional radiography despite the reduction in exposure dose and a slightly diminished image quality. High spatial frequency enhancement did not provide further diagnostic information and is therefore superfluous in barium enemas. (orig.)

  7. Radiographic film cassette

    International Nuclear Information System (INIS)

    This patent specification describes the design of a radiographic cassette which combines the advantages of a classical cassette and the polymeric bag, on the one hand having an overall rigidity, imparted by the bottom and the marginal part of the cover as they are locked together, and on the other hand the object to be radiographed can be located very close to a film/screen set in the cassette because only the thickness of a flexible foil has to intervene. The cassette has the means by which the air can be a spirated from the inside after closure, and may have an intensifying screen which contacts that side of the flexible foil which faces the interior of the cassette. A preferred field of application is for mammography techniques. (U.K.)

  8. A new double contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Sang; Cho, Won Sik; Lee, Sung Woo; Lee, Mun Gyu; Jeon, Jeong Dong; Jaun, Woo Ki; Han, Chung Yul [Inje College Paik Hospital, Pusan (Korea, Republic of)

    1987-12-15

    A new technic of the barium enema was proposed for the better colonic double contrast study with the average 204ml of 50w/v% barium, applied to 109 serial patients. The barium was introduced to sigmoid colon, and then pushed to a mid transverse colon by the air insufflation through an enema syringe, a new device. An advance to cecum is accomplished by the air insufflation and/or the position change of the patient. The barium transfer method was developed for the best spot film exposure, through colon, by the position change of the patient, the tilting of the x-ray table and the air insufflation with the enema syringe. The mean angle of the x-ray table tilted was -10 .deg. at the beginning the barium enema till the barium sent past the splenic flexure, -15 . deg. for the best lateral view of rectum and -18 .deg. for the bet prone PA view of rectosigmoid colon. This was a simple, better and economic double contrast barium enema for the cooperative patients.

  9. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  10. Synthesis of barium titanium oxide from barium sulphate and anatase. Study of equimolar mixtures under different atmospheres

    International Nuclear Information System (INIS)

    To enable the ceramization of a barium sulphate-rich radioactive waste the synthesis of barium titanium oxide is studied by using anatase and barium sulphate. As a function of the calcination atmosphere, helium (or air) and Ar/H2, two reactions are studied. A mechanism of barium titanium oxide synthesis in helium (or in air) is proposed

  11. Double contrast barium meal and acetylcysteine

    International Nuclear Information System (INIS)

    In a prospective double blind study, acetylcysteine, a local and systemic respiratory tract mucolytic agent, or a placebo, were given to 100 patients prior to a double contrast barium meal to decrease the gastric mucus viscosity and to make the mucus layer thinner, in order to permit barium to outline the furrows surrounding the areae gastricae instead of the overlying thick mucus. However, acetylcysteine failed to improve either visualization of the areae gastricae or the general quality of the double contrast barium meal. (orig.)

  12. Barium adsorption on the (110) and (111) molybdenum faces

    Energy Technology Data Exchange (ETDEWEB)

    Azizov, U.V.; Sabirov, S.T.; Dzhalilov, S.T. (Tashkentskij Gosudarstvennyj Univ. (USSR))

    1982-07-01

    Barium adsorption on Mo faces (110) and (111) was investigated by thermoemission and Cs surface ionization methods to obtain a more broad representation of barium adsorption at higher temperatures of cathode. Experiments show that the substrate temperature increase at a constant barium concentration results in the formation of small barium islands. At that, barium is under similar energy conditions in the small islands formed on the face (110) independent of relative areas of the islands.

  13. In vitro tests of barium sulphate suspensions for double contrast examinations of the stomach

    International Nuclear Information System (INIS)

    Four barium sulphate suspensions were investigated with respect to their adhesion and contrast following standard means of spreading the contrast over a model stomach, which corresponds in its detailed structure with the surface of the gastric mucosa. By this means various factors, which make a true comparison in vivo impossible, could be eliminated and a comparison of the suspensions became possible. Using similar mechanical and chemical situations, the radiographs of the artificial mucosa showed very different results from the use of the different preparations. These corresponded well with the findings in vivo. (orig.)

  14. Early manifestation of Yersinia colitis demonstrated by the double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Aspestrand, F.

    1986-11-01

    A 19-year old female with a bloody, diarrheal illness of acute onset where Crohn's disease primarly was suspected is presented. The double-contrast barium enema revealed multiple, diffusely scattered aphthous erosions of the colonic mucosa: the rectum was scarcely affected. Biopsies taken by endoscopy demonstrated nonspecific inflammatory changes of the mucous membrane. However, routinely taken stool cultures revealed an infectious colitis due to Yersinia enterocolitica. Our case demonstrates the necessity to consider Yersinia enterocolitis in the radiographic differential diagnosis when the diagnosis of Crohn's disease or ulcerative colitis seems obvious.

  15. Barium Isotopes in Single Presolar Grains

    Science.gov (United States)

    Pellin, M. J.; Davis, A. M.; Savina, M. R.; Kashiv, Y.; Clayton, R. N.; Lewis, R. S.; Amari, S.

    2001-01-01

    Barium isotopic compositions of single presolar grains were measured by laser ablation laser resonant ionization mass spectrometry and the implications of the data for stellar processes are discussed. Additional information is contained in the original extended abstract.

  16. Radiographic solution contamination.

    Science.gov (United States)

    Hardman, P K; Tilmon, M F; Taylor, T S

    1987-06-01

    Contamination of processor solutions adversely affects the image quality of radiographic films. The purpose of this study was to determine the amount of developer or fixer contaminant that was necessary to produce a significant densitometric change in the base plus fog, speed, or contrast optical density readings for panoramic film. Significant differences in base plus fog (after 16 mL of fixer contaminant was added to developer), speed index (after 4 mL), and contrast index (after 8 mL) were observed in comparison with control values. PMID:3473399

  17. Peritoneal tuberculosis: radiographic diagnosis

    Directory of Open Access Journals (Sweden)

    Carolina Ospina-Moreno

    2014-12-01

    Full Text Available Peritoneal tuberculosis (TB is an extrapulmonary form of presentation of tuberculosis. HIV infection is a primary risk factor for this condition. Diagnosis requires microbiological or histopathological confirmation in addition to supporting radiological imaging studies. Abdominal ultrasonography and CT are useful to obtain a radiographic diagnosis, with typical findings including diffuse peritoneal thickening, presence of ascites in varying volumes, adenopathies, and caseating nodes. We report 2 cases of patients with ascites and nodular peritoneal thickening on diagnostic images, as well as high CA-125 levels in laboratory tests. In both patients, a diagnosis of peritoneal tuberculosis was reached following a US-guided peritoneal biopsy.

  18. An experimental study on barium peritonitis in rats

    International Nuclear Information System (INIS)

    Barium sulfate is universally used contrast media in gastrointestinal roentgenology, and spillage of barium into peritoneal cavity can occur. The references on effect of barium sulfate in the peritoneal cavity have been scattered and the results are varied. In 80 rats, body weight of 130 gm to 150 gm, sterile pure barium, sterile commercial barium, intestinal content, and mixed pure barium and intestinal content were experimentally injected into the peritoneal cavity. Consecutive weekly laparotomy and microscopic examination were done for 4 weeks. The results are as followings: 1. Mind inflammatory reaction and mild adhesion after sterile pure barium injection. 2. Mild inflammatory reaction and moderate adhesion after sterile commercial barium injection. 3. Acute peritonitis and abscess formation after intestinal content injection. 4. High mortality due to severe acute peritonitis, and severe adhesion in survivors after injection of both pure barium and intestinal content.

  19. Bacterial Reduction Of Barium Sulphate By Sulphate-Reducing Bacteria

    Directory of Open Access Journals (Sweden)

    Luptáková Alena

    2015-12-01

    Full Text Available Acid mine drainage (AMD is a worldwide problem leading to contamination of water sources. AMD are characterized by low pH and high content of heavy metals and sulphates. The barium salts application presents one of the methods for the sulphates removing from AMD. Barium chloride, barium hydroxide and barium sulphide are used for the sulphates precipitation in the form of barium sulphate. Because of high investment costs of barium salts, barium sulphide is recycled from barium sulphate precipitates. It can be recycled by thermic or bacterial reduction of barium sulphate. The aim of our study was to verify experimentally the possibility of the bacterial transformation of BaSO4 to BaS by sulphate-reducing bacteria. Applied BaSO4 came from experiments of sulphates removal from Smolnik AMD using BaCl2.

  20. Radiographic signs of pulmonary diseases

    International Nuclear Information System (INIS)

    The first part of the radiographic interpretation in pulmonary radiography is the description of radiographic signs. They are presented in terms of: (i) changes in pulmonary volume and (ii) changes in pulmonary density. Changes in density should be precisely located and characterized. A protocole for the description of pulmonary changes is therefore proposed. A few words are then said on how to interprete these radiographic signs

  1. Contamination of dental radiographic solutions.

    Science.gov (United States)

    Tamburus, J R; Pardini, L C; Watanabe, P C

    1995-01-01

    Thirteen groups of periapical radiographic films were evaluated to determine and compare within and between groups the effects of contamination of the fixer solution with developing solution during radiographic processing. An aluminum penetrometer was used as the radiographic object to produce different optical densities. The images were compared using radiographic density and contrast as parameters. There were significant differences between the control groups and the groups processed with a contaminated fixer solution. No statistically significant differences were observed in the intragroup comparisons. PMID:8688649

  2. Thermochemical hydrogen production via a cycle using barium and sulfur - Reaction between barium sulfide and water

    Science.gov (United States)

    Ota, K.; Conger, W. L.

    1977-01-01

    The reaction between barium sulfide and water, a reaction found in several sulfur based thermochemical cycles, was investigated kinetically at 653-866 C. Gaseous products were hydrogen and hydrogen sulfide. The rate determining step for hydrogen formation was a surface reaction between barium sulfide and water. An expression was derived for the rate of hydrogen formation.

  3. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  4. Synthesis of barium mercaptides and application of antimony/barium mercaptides

    Institute of Scientific and Technical Information of China (English)

    瞿龙; 张露露; 舒万艮

    2001-01-01

    Mercaptoacetic acid, isooctyl thioglycolate and barium hydroxide used as start materials, barium bis (2-ethylhexyl thioglycolate) (Ba(2EHTG)2), barium thioglycolate (Ba(TG)) and barium bisthioglycolate (Ba(TG)2) were synthesized. Their optimum synthetic techniques were discussed, and some physicochemical data were reported. Infrared spectroscopy and elemental analysis methods were used to identify the structures. They were put into PVC plastic products together with antimony tris (2-ethylhexyl thioglycolate) (Sb(2EHTG)3) under the suitable compounding, and their heat stability to PVC was studied. It is shown that these barium mercaptides have remarkable synergisms with antimony mercaptides and the long-term stabilizing effect of organoantimony stabilizer can be effectively improved, reducing the amount of antimony compounds so as to avoid the decrease of its stabilizing effect.

  5. Chemical abundances and kinematics of barium stars

    Science.gov (United States)

    de Castro, D. B.; Pereira, C. B.; Roig, F.; Jilinski, E.; Drake, N. A.; Chavero, C.; Silva, J. V. Sales

    2016-04-01

    In this paper we present an homogeneous analysis of photospheric abundances based on high-resolution spectroscopy of a sample of 182 barium stars and candidates. We determined atmospheric parameters, spectroscopic distances, stellar masses, ages, luminosities and scale height, radial velocities, abundances of the Na, Al, alpha-elements, iron-peak elements, and s-process elements Y, Zr, La, Ce, and Nd. We employed the local-thermodynamic-equilibrium model atmospheres of Kurucz and the spectral analysis code MOOG. We found that the metallicities, the temperatures and the surface gravities for barium stars can not be represented by a single gaussian distribution. The abundances of alpha-elements and iron peak elements are similar to those of field giants with the same metallicity. Sodium presents some degree of enrichment in more evolved stars that could be attributed to the NeNa cycle. As expected, the barium stars show overabundance of the elements created by the s-process. By measuring the mean heavy-element abundance pattern as given by the ratio [s/Fe], we found that the barium stars present several degrees of enrichment. We also obtained the [hs/ls] ratio by measuring the photospheric abundances of the Ba-peak and the Zr-peak elements. Our results indicated that the [s/Fe] and the [hs/ls] ratios are strongly anti-correlated with the metallicity. Our kinematical analysis showed that 90% of the barium stars belong to the thin disk population. Based on their luminosities, none of the barium stars are luminous enough to be an AGB star, nor to become self-enriched in the s-process elements. Finally, we determined that the barium stars also follow an age-metallicity relation.

  6. Chemical abundances and kinematics of barium stars

    Science.gov (United States)

    de Castro, D. B.; Pereira, C. B.; Roig, F.; Jilinski, E.; Drake, N. A.; Chavero, C.; Sales Silva, J. V.

    2016-07-01

    In this paper, we present an homogeneous analysis of photospheric abundances based on high-resolution spectroscopy of a sample of 182 barium stars and candidates. We determined atmospheric parameters, spectroscopic distances, stellar masses, ages, luminosities and scaleheight, radial velocities, abundances of the Na, Al, α-elements, iron-peak elements, and s-process elements Y, Zr, La, Ce, and Nd. We employed the local thermodynamic equilibrium model atmospheres of Kurucz and the spectral analysis code MOOG. We found that the metallicities, the temperatures and the surface gravities for barium stars cannot be represented by a single Gaussian distribution. The abundances of α-elements and iron peak elements are similar to those of field giants with the same metallicity. Sodium presents some degree of enrichment in more evolved stars that could be attributed to the NeNa cycle. As expected, the barium stars show overabundance of the elements created by the s-process. By measuring the mean heavy-element abundance pattern as given by the ratio [s/Fe], we found that the barium stars present several degrees of enrichment. We also obtained the [hs/ls] ratio by measuring the photospheric abundances of the Ba-peak and the Zr-peak elements. Our results indicated that the [s/Fe] and the [hs/ls] ratios are strongly anticorrelated with the metallicity. Our kinematical analysis showed that 90 per cent of the barium stars belong to the thin disc population. Based on their luminosities, none of the barium stars are luminous enough to be an asymptotic giant branch star, nor to become self-enriched in the s-process elements. Finally, we determined that the barium stars also follow an age-metallicity relation.

  7. Radiographic study of ameloblastoma

    International Nuclear Information System (INIS)

    The purpose of this study is to obtain some information for the differential diagnosis of ameloblastoma from dentigerous cyst by analysis of the radiographic findings of these lesions. The author studied age and sex distribution, the site of the lesion, tooth behavior and several radiographic features of ameloblastoma and dentigerous cyst. The material consisted of 65 patients of ameloblastoma and 37 patients of dentigerous cyst. The results were obtained as followings. 1) The incidence was highest in 2nd decade (29.2%) and total 65 cases consists of 35 males (53.8%) and 30 females (46.2%) in ameloblastoma. 62 cases were found in lower jaw (95.4%) and the highest site of occurrence of ameloblastoma was mandibular molar region 27 cases.(41.5%) 2) In 65 cases of ameloblastoma, 18 cases were seen in association with tooth and 15 cases (83.2%) out of those were associated with mandibular molar teeth. Mandibular molar were most frequently involved in dentigerous cyst (11/37 cases, 29.7%). 3) (a) 23 cases (35.3%) of tooth resorption were found in ameloblastoma and 11 cases (29.7%) of tooth resorption were found in dentigerous cyst. (b) 15 cases (23.1%) of tooth migration were found in ameloblastoma and 10 cases (27.0%) of tooth migration were found in dentigerous cyst. 4) Several radiographic features. (a) Monolocular type ameloblastoma were seen in 23 cases (35.4) and multilocular type of ameloblastoma were seen in 42 cases (64.6%). Monolocular type of dentigerous cyst were seen in 33 cases (89.2%) and multilocular type was seen in 4 cases. (b) Monolocular type ameloblastoma showed 20 cases (87.0%) of scalloped border but 32 cases (97.0%) of dentigerous cyst showed smooth border. (c) 34 cases (81.0%) of ameloblastoma showed honey-comb appearance, soap-bubble appearance or mixed appearance. But all 4 cases of dentigerous cyst showed multicystic appearance. (d) 12 cases (52.2%) of monolocular type ameloblastoma showed slightly increased radiopacity in surrounding bone

  8. Can radiographers read screening mammograms?

    International Nuclear Information System (INIS)

    AIM: To evaluate the ability of radiographers to read screening mammograms in the National Health Service Breast Screening Programme (NHSBSP). MATERIALS AND METHODS: Two radiographers read a test set of 1000 screening mammograms previously reported by a consultant radiologist. Three radiographers then acted as a second reader for 54,000 screening mammograms, their recall results are presented. Four consultant radiologists and three film reading radiographers were timed while reading 2500 mammograms each. RESULTS: When reading the test mammograms the two radiographers recalled all the cancers previously detected by the radiologist at the original screen read. They also recalled 32/90 women who subsequently presented with interval cancers. As a second reader the radiographers had similar recall and cancer detection rates to the radiologists (P > 0.05). Double reading detected 9% more cancers. The radiographers take the same length of time to film read as radiologists (P > 0.05). CONCLUSION: Radiographers are able to read screening mammograms at least as well as radiologists and do not take longer to do so. Wivell, G., et al. (2003). Clinical Radiology58, 63--67

  9. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  10. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p<0.05) in the recognition of disintegration after lithotripsy was found for the processed digitized images. On the basis of this initial investigation, the digitization system tested appears to be useful for diagnostic purposes, especially when contrast resolution plays an important part, as with stone fragmentation or cortical defects. (orig.)

  11. Focussed radiographic camera

    International Nuclear Information System (INIS)

    A radiographic camera of the form employing a scintillator for producing optical photons in response to incident gamma and x-radiation is described. A collimator is positioned between a subject emitting such radiation and the scintillator for guiding the radiation to the scintillator and a detector of optical photons for signaling the positions of points of impingement of quanta of the incident radiation upon the scintillator to produce an image of the subject. A Fresnel focussing means is located alongside the scintillator for directing the optical photons to the detector. The Fresnel focussing means takes the form of a segmented mirror at the front surface of the scintillator and a Fresnel lens at the back surface of the scintillator

  12. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium...

  13. Coprecipitation of iron and silver with barium fluoride

    International Nuclear Information System (INIS)

    Distribution of trace contaminants of iron and silver at coprecipitation of barium fluoride is studied in present work. It is defined that iron almost completely coprecipitated with barium fluoride in wide range of ph 5.5-12. Silver coprecipitated with barium fluoride in ph range 4-7. The value of coprecipitation varies from 94% to 100%.

  14. Recrystallization of 223Ra with barium sulfate

    International Nuclear Information System (INIS)

    In this work, the kinetics of barium sulfate recrystallization has been studied in acidic 0.01 mol dm-3 sodium sulfate solution using 223Ra and 133Ba tracers at very low total radium concentration, i.e. less than 10-13 mol dm-3. It was found that the system follows the homogeneous recrystallization model and that recrystallization rates, inferred by the decrease of 223Ra and 133Ba in the aqueous solution, are fast. Therefore, even at very low concentrations, below the solubility limit, radium will be retained by barium sulfate-a mineral present in the deep underground repository. (author)

  15. Printed Barium Strontium Titanate capacitors on silicon

    International Nuclear Information System (INIS)

    In this paper, we show that Barium Strontium Titanate (BST) films can be prepared by inkjet printing of sol–gel precursors on platinized silicon substrate. Moreover, a functional variable capacitor working in the GHz range has been made without any lithography or etching steps. Finally, this technology requires 40 times less precursors than the standard sol–gel spin-coating technique. - Highlights: • Inkjet printing of Barium Strontium Titanate films • Deposition on silicon substrate • Inkjet printed silver top electrode • First ever BST films thinner than 1 μm RF functional variable capacitor that has required no lithography

  16. Printed Barium Strontium Titanate capacitors on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Sette, Daniele [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg); Kovacova, Veronika [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Defay, Emmanuel, E-mail: emmanuel.defay@list.lu [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg)

    2015-08-31

    In this paper, we show that Barium Strontium Titanate (BST) films can be prepared by inkjet printing of sol–gel precursors on platinized silicon substrate. Moreover, a functional variable capacitor working in the GHz range has been made without any lithography or etching steps. Finally, this technology requires 40 times less precursors than the standard sol–gel spin-coating technique. - Highlights: • Inkjet printing of Barium Strontium Titanate films • Deposition on silicon substrate • Inkjet printed silver top electrode • First ever BST films thinner than 1 μm RF functional variable capacitor that has required no lithography.

  17. Chest radiographic findings of leptospirosis

    International Nuclear Information System (INIS)

    1. A study on chest radiographic findings of 54 cases with pneumonia like symptoms was performed. Of 54 cases, 8 cases were confirmed to be leptospirosis and 7 cases were leptospirosis combined with Korean hemorrhagic fever. 2. Of 8 cases of leptospirosis, 4 cases showed abnormal chest radiographic findings: acinar nodular type 2, massive confluent consolidation type 2. Of 7 cases of leptospirosis combined with Korean hemorrhagic fever: acinar nodular type 3, massive confluent consolidation type 1, and increased interstitial markings type 1 respectively. 3. It was considered to be difficult to diagnose the leptospirosis on chest radiographic findings alone, especially the case combined with Korean hemorrhagic fever.

  18. Chest radiographic findings of leptospirosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mee Hyun; Jung, Hee Tae; Lee, Young Joong; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1986-04-15

    1. A study on chest radiographic findings of 54 cases with pneumonia like symptoms was performed. Of 54 cases, 8 cases were confirmed to be leptospirosis and 7 cases were leptospirosis combined with Korean hemorrhagic fever. 2. Of 8 cases of leptospirosis, 4 cases showed abnormal chest radiographic findings: acinar nodular type 2, massive confluent consolidation type 2. Of 7 cases of leptospirosis combined with Korean hemorrhagic fever: acinar nodular type 3, massive confluent consolidation type 1, and increased interstitial markings type 1 respectively. 3. It was considered to be difficult to diagnose the leptospirosis on chest radiographic findings alone, especially the case combined with Korean hemorrhagic fever.

  19. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  20. Enterogastroesophageal reflux during barium enema: Report of a case

    International Nuclear Information System (INIS)

    Enterogastric reflux during barium enema examination has been ascribed to various causes including incompetence of the ilepcecal valve, shunt, fistula, excessive barium etc. Recently we have encountered a case of complete enterogastroesphageal regurgitation during barium enema examination performed for the reduction of the ileocolic intuosusception in 6 months old baby. The regurgitation occurred only in the first of two barium enema examinations conducted at one month interval for recurring intussusception. The barium-saline solution used in the present study was not more than 350 ml in quantity. No organic or physical causes of such a complete regurgitation could be determined

  1. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  2. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  3. Origins of the Reporting Radiographer

    OpenAIRE

    Lockwood, P

    2013-01-01

    A talk on the ‘The Origins of the Reporting Radiographer’, looking at the changing roles and practice of the profession from the first x-ray technicians at the start of the 20th century, through two World Wars to the start of radiographer reporter training from 1994. Christ Church was the first institution worldwide to offer postgraduate opportunities in Clinical Reporting, starting with a pilot programme by Keith Piper (Principal Lecturer) in 1994 accredited to teach NHS Radiographers to...

  4. 75 FR 19657 - Barium Chloride From China

    Science.gov (United States)

    2010-04-15

    ... Commission found that the domestic interested party group response to its notice of institution (74 FR 31757... COMMISSION Barium Chloride From China AGENCY: United States International Trade Commission. ACTION: Notice of Commission determination to conduct a full five-year review concerning the antidumping duty order on...

  5. Impurities in barium titanate posistor ceramics

    Czech Academy of Sciences Publication Activity Database

    Korniyenko, S. M.; Bykov, I. P.; Glinchuk, M. J.; Laguta, V. V.; Belous, A. G.; Jastrabík, Lubomír

    2000-01-01

    Roč. 239, - (2000), s. 1209-1218. ISSN 0015-0193 Institutional research plan: CEZ:AV0Z1010914 Keywords : barium titanate phase transition * ESR * positive temperature coefficient of resistivity Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.547, year: 2000

  6. 75 FR 20625 - Barium Chloride From China

    Science.gov (United States)

    2010-04-20

    ... established a schedule for the conduct of this review (74 FR 62587, November 30, 2010). Subsequently, counsel... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Barium Chloride From China AGENCY: United States International Trade Commission. ACTION:...

  7. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...

  8. Radiographic features of esophageal involvement in chronic graft-vs.-host disease.

    Science.gov (United States)

    McDonald, G B; Sullivan, K M; Plumley, T F

    1984-03-01

    Chronic graft-vs.-host disease (GVHD) is an important late complication of allogeneic bone-marrow transplantation. It resembles several naturally occurring autoimmune diseases and involves the skin, mouth, eyes, liver, and esophagus. The radiographic findings of 14 symptomatic patients with chronic GVHD involving the esophagus were reviewed and found to include webs, ringlike narrowings, and tapering strictures in the mid and upper esophagus. Esophagoscopy revealed characteristic desquamation in the 13 patients studied, but barium studies detected this lesion in only one patient. Knowledge of the site and characteristics of esophageal involvement with chronic GVHD assists the radiologic evaluation of this disorder. PMID:6607634

  9. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    International Nuclear Information System (INIS)

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound

  10. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, J.P. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Duarte, G.W. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Research Group in Technology and Information, Centro Universitário Barriga Verde (UNIBAVE), Santa Catarina, SC (Brazil); Caldart, C. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Kniess, C.T. [Post-Graduate Program in Professional Master in Management, Universidade Nove de Julho, São Paulo, SP (Brazil); Montedo, O.R.K.; Rocha, M.R. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Riella, H.G. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Fiori, M.A., E-mail: fiori@unochapeco.edu.br [Post-Graduate Program in Environmental Science, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil); Post-Graduate Program in Technology and Management of the Innovation, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil)

    2015-11-15

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound.

  11. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  12. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  13. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  14. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  15. Radioactive Barium Ion Trap Based on Metal-Organic Framework for Efficient and Irreversible Removal of Barium from Nuclear Wastewater.

    Science.gov (United States)

    Peng, Yaguang; Huang, Hongliang; Liu, Dahuan; Zhong, Chongli

    2016-04-01

    Highly efficient and irreversible capture of radioactive barium from aqueous media remains a serious task for nuclear waste disposal and environmental protection. To address this task, here we propose a concept of barium ion trap based on metal-organic framework (MOF) with a strong barium-chelating group (sulfate and sulfonic acid group) in the pore structures of MOFs. The functionalized MOF-based ion traps can remove >90% of the barium within the first 5 min, and the removal efficiency reaches 99% after equilibrium. Remarkably, the sulfate-group-functionalized ion trap demonstrates a high barium uptake capacity of 131.1 mg g(-1), which surpasses most of the reported sorbents and can selectively capture barium from nuclear wastewater, whereas the sulfonic-acid-group-functionalized ion trap exhibits ultrafast kinetics with a kinetic rate constant k2 of 27.77 g mg(-1) min(-1), which is 1-3 orders of magnitude higher than existing sorbents. Both of the two MOF-based ion traps can capture barium irreversibly. Our work proposes a new strategy to design barium adsorbent materials and provides a new perspective for removing radioactive barium and other radionuclides from nuclear wastewater for environment remediation. Besides, the concrete mechanisms of barium-sorbent interactions are also demonstrated in this contribution. PMID:26999358

  16. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Radiological departments are changing rapidly due to the implementation of digital images and PACS (Picture Archiving and Communication Systems). The introduction of new technology seems to dissolve boundaries between the professions in the work environment where the technology is introduced. This process tends to change the organization and its routines. The aim of this qualitative study is to explore changes in radiographers' work with regard to skills, work practice and technology. The study used open-ended interviews to explore the radiographers' perceptions of such changes, and to identify problems and solutions pertaining to work practice. Inspiration is taken from grounded theory to explain the changes in work that were found. Respondents were selected from a total of 133 potential participants as a theoretical or purposive sample. The changing trends within the professional role indicated that radiographers, as image producers, shifted their focus from the ability to set the optimal exposure parameters in order to obtain the optimal image for diagnosis to become expert in exposure parameters, projection techniques and diagnostic practice, having multifaceted skills, as being the jack of all trades. When implementing PACS there was an obvious change in image production. At the start there were visions of new routines, and therefore the radiographers became early adopters to the new technology; in practice the organization was stacked in old routines, as the routines were inflexible and PACS work was pushed into old work routines. Although inflexible, this does not mean that they cannot change, and obviously in 2006 new routines had been implemented making it possible for the radiographers in finding new ways for collaborating with colleagues. The new technology immediately created a vision of improved service to the clinicians. In order to optimize the service the radiographers developed an insight into the need for a more comprehensive change in work using

  17. Monitoring Radiographic Brain Tumor Progression

    Directory of Open Access Journals (Sweden)

    John H. Sampson

    2011-03-01

    Full Text Available Determining radiographic progression in primary malignant brain tumors has posed a significant challenge to the neuroncology community. Glioblastoma multiforme (GBM, WHO Grade IV through its inherent heterogeneous enhancement, growth patterns, and irregular nature has been difficult to assess for progression. Our ability to detect tumor progression radiographically remains inadequate. Despite the advanced imaging techniques, detecting tumor progression continues to be a clinical challenge. Here we review the different criteria used to detect tumor progression, and highlight the inherent challenges with detection of progression.

  18. Interpreting radiographs. 1. The foot

    International Nuclear Information System (INIS)

    Radiography of the foot of a conscious standing horse is within the capability of all modern portable X-ray machines; radiographic examination of the feet of horses with long-standing lameness is frequently carried out in practice. With the introduction of modern fast intensifying screens and films there is little excuse for poor results caused by movement or the low output of portable machines. Sadly, although the foot is the most commonly radiographed part of the horse, a high percentage of the films taken are not of diagnostic quality. This is due, first, to over exposure, secondly, to poor developing techniques and thirdly, to poor positioning

  19. Prospects for Barium Tagging in Gaseous Xenon

    International Nuclear Information System (INIS)

    Tagging events with the coincident detection of a barium ion would greatly reduce the background for a neutrino-less double beta decay search in xenon. This paper describes progress towards realizing this goal. It outlines a source that can produce large quantities of Ba++ in gas, shows that this can be extracted to vacuum, and demonstrates a mechanism by which the Ba++ can be efficiently converted to Ba+ as required for laser identification.

  20. Production of translationally cold barium monohalide ions

    OpenAIRE

    DePalatis, M. V.; Chapman, M.S.

    2013-01-01

    We have produced sympathetically cooled barium monohalide ions BaX$^+$ (X = F, Cl, Br) by reacting trapped, laser cooled Ba$^+$ ions with room temperature gas phase neutral halogen-containing molecules. Reaction rates for two of these (SF$_6$ and CH$_3$Cl) have been measured and are in agreement with classical models. BaX$^+$ ions are promising candidates for cooling to the rovibrational ground state, and our method presents a straightforward way to produce these polar molecular ions.

  1. Chemical abundances and kinematics of barium stars

    CERN Document Server

    de Castro, D B; Roig, F; Jilinski, E; Drake, N A; Chavero, C; Silva, J V Sales

    2016-01-01

    In this paper we present an homogeneous analysis of photospheric abundances based on high-resolution spectroscopy of a sample of 182 barium stars and candidates. We determined atmospheric parameters, spectroscopic distances, stellar masses, ages, luminosities and scale height, radial velocities, abundances of the Na, Al, $alpha$-elements, iron-peak elements, and s-process elements Y, Zr, La, Ce, and Nd. We employed the local-thermodynamic-equilibrium model atmospheres of Kurucz and the spectral analysis code {\\sc moog}. We found that the metallicities, the temperatures and the surface gravities for barium stars can not be represented by a single gaussian distribution. The abundances of $alpha$-elements and iron peak elements are similar to those of field giants with the same metallicity. Sodium presents some degree of enrichment in more evolved stars that could be attributed to the NeNa cycle. As expected, the barium stars show overabundance of the elements created by the s-process. By measuring the mean heav...

  2. Barium hexaferrite nanoparticles: Synthesis and magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Martirosyan, K.S., E-mail: karen.martirosyan@utb.edu [Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204 (United States); Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204 (United States); Galstyan, E. [Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Hossain, S.M.; Wang Yiju [Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204 (United States); Litvinov, D. [Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204 (United States); Texas Center for Superconductivity, University of Houston, Houston, TX 77204 (United States); Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204 (United States)

    2011-01-15

    Carbon combustion synthesis is applied to rapid and energy efficient fabrication of crystalline barium hexaferrite nanoparticles with the average particle size of 50-100 nm. In this method, the exothermic oxidation of carbon nanoparticles with an average size of 5 nm with a surface area of 80 m{sup 2}/g generates a self-propagating thermal wave with maximum temperatures of up to 1000 deg. C. The thermal front rapidly propagates through the mixture of solid reactants converting it to the hexagonal barium ferrite. Carbon is not incorporated in the product and is emitted from the reaction zone as a gaseous CO{sub 2}. The activation energy for carbon combustion synthesis of BaFe{sub 12}O{sub 19} was estimated to be 98 kJ/mol. A complete conversion to hexagonal barium ferrite is obtained for carbon concentration exceeding 11 wt.%. The magnetic properties H{sub c}{approx}3000 Oe and M{sub s}{approx}50.3 emu/g of the compact sintered ferrites compare well with those produced by other synthesis methods.

  3. Barium hexaferrite nanoparticles: Synthesis and magnetic properties

    International Nuclear Information System (INIS)

    Carbon combustion synthesis is applied to rapid and energy efficient fabrication of crystalline barium hexaferrite nanoparticles with the average particle size of 50-100 nm. In this method, the exothermic oxidation of carbon nanoparticles with an average size of 5 nm with a surface area of 80 m2/g generates a self-propagating thermal wave with maximum temperatures of up to 1000 deg. C. The thermal front rapidly propagates through the mixture of solid reactants converting it to the hexagonal barium ferrite. Carbon is not incorporated in the product and is emitted from the reaction zone as a gaseous CO2. The activation energy for carbon combustion synthesis of BaFe12O19 was estimated to be 98 kJ/mol. A complete conversion to hexagonal barium ferrite is obtained for carbon concentration exceeding 11 wt.%. The magnetic properties Hc∼3000 Oe and Ms∼50.3 emu/g of the compact sintered ferrites compare well with those produced by other synthesis methods.

  4. Lanthanide doped strontium-barium cesium halide scintillators

    Science.gov (United States)

    Bizarri, Gregory; Bourret-Courchesne, Edith; Derenzo, Stephen E.; Borade, Ramesh B.; Gundiah, Gautam; Yan, Zewu; Hanrahan, Stephen M.; Chaudhry, Anurag; Canning, Andrew

    2015-06-09

    The present invention provides for a composition comprising an inorganic scintillator comprising an optionally lanthanide-doped strontium-barium, optionally cesium, halide, useful for detecting nuclear material.

  5. Spasmolytic effect of peppermint oil in barium during double-contrast barium enema compared with Buscopan

    Energy Technology Data Exchange (ETDEWEB)

    Asao, T.; Kuwano, H.; Ide, M.; Hirayama, I.; Nakamura, J.-I.; Fujita, K.-I.; Horiuti, R

    2003-04-01

    AIM: To evaluate the efficacy of peppermint oil in barium as a spasmolytic agent during a double-contrast barium enema (DCBE). MATERIALS AND METHODS: A total of 383 DCBEs with positive results from occult blood tests were assessed. Patients were assigned to one of four groups: peppermint in barium (n=91), peppermint in tube (n=90), Buscopan (n=105), or no treatment (n=97). After a screening sigmoidoscopy, the DCBEs were performed using air as a distending gas. In the Buscopan group, the DCBE was performed with an intramuscular injection of 20 mg Buscopan at the start of the examination. Patients in the no-treatment group underwent DCBE without any spasmolytic agent. A peppermint oil preparation (30 ml) was mixed in the barium solution for patients in the peppermint-in-barium group, and the same dose of peppermint oil was included in the enema tube in the peppermint-in-tube group. The presence of spasm on a series of spot films was evaluated without information about the type of spasmolytic agent used. RESULTS: The percentage of patients in the four groups (no treatment, Buscopan, peppermint in tube, and peppermint in barium) with absence of spasm in the entire colon on the series of spot films was 13.4, 38.1, 41.8, and 37.8%, respectively. In the group using peppermint oil or Buscopan, the rate of patients with non-spasm examination was higher than that in no-treatment group (p<0.0005). Peppermint oil had the same spasmolytic effect as the systemic administration of Buscopan in the transverse and descending colon. Peppermint oil had a stronger effect in the caecum and the ascending colon than a Buscopan injection (p<0.005). There was no advantage to placing peppermint oil in the enema tube over mixing it in the barium solution. A total of 157 polyps were found during the DCBE procedures, and no differences were observed in the number of lesions among the four groups. Peppermint oil did not impair image quality. CONCLUSION: Barium solution mixed with peppermint oil

  6. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.)

  7. Routine radiographic assessment of the scoliotic spine.

    Science.gov (United States)

    Farren, J

    1981-04-01

    This paper is designed to give a brief account of the radiographic criteria necessary in order to demonstrate and evaluate the scoliotic spine. However, additional specialised radiographic examinations, including myelography, angiography, laminography and intravenous urography are occasionally necessary. PMID:7280196

  8. Tarsal navicular stress fractures: radiographic evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pavlov, H.; Torg, J.S.; Freiberger, R.H.

    1983-09-01

    Tarsal navicular stress fractures are a potential source of disabling foot pain in physically active individuals. The diagnosis of tarsal navicular stress fracture requires a high index of clinical and radiographic suspicion because the fracture is only rarely evident on routine radiographs or standard tomograms. The radiographic diagnosis of a tarsal navicular stress fracture may require anatomic anteroposterior tomograms or a radionuclide bone scan with plantar views. Radiographic examinations of 23 fractures in 21 patients are evaluated.

  9. Tarsal navicular stress fractures: radiographic evaluation

    International Nuclear Information System (INIS)

    Tarsal navicular stress fractures are a potential source of disabling foot pain in physically active individuals. The diagnosis of tarsal navicular stress fracture requires a high index of clinical and radiographic suspicion because the fracture is only rarely evident on routine radiographs or standard tomograms. The radiographic diagnosis of a tarsal navicular stress fracture may require anatomic anteroposterior tomograms or a radionuclide bone scan with plantar views. Radiographic examinations of 23 fractures in 21 patients are evaluated

  10. Analysis of polyethylene wear in plain radiographs

    OpenAIRE

    Stilling, Maiken; Søballe, Kjeld; Andersen, Niels Trolle; Larsen, Kristian; Rahbek, Ole

    2009-01-01

    Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs. Methods We used either 1, 2, or 6 anteroposterior (AP) hip radiographs ...

  11. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community of...... a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the...... radiographs and assessing their radiographic image quality on an arbitrary scale....

  12. Barium enema findings of milk allergy in infants

    International Nuclear Information System (INIS)

    We wanted to evaluate the barium enema findings of milk allergy in infants. Retrospective evaluation of the plain abdominal radiography and barium enema findings was performed in fifteen young infants suffering with milk allergy. The presence of gaseous distension, rectal gas, paralytic ileus and mechanical obstruction was evaluated on the plain radiography. The presence of spasm, a transitional zone, a reversed rectosigmoid index and mucosal irregularity was analyzed on the barium enema; the presence of barium retention was also evaluated on 24-hour-delayed plain radiography. Paralytic ileus was the most common finding on the plain radiography (93%). On the barium enema, continuous spasm of the colon, ranging from the rectum to the descending colon, was revealed in ten infants (67%). A transitional zone was observed in one infant and a reversed rectosigmoid index was revealed in four. Mucosal irregularity was observed in two infants. Barium retention was demonstrated in 11 of fifteen cases: throughout the entire colon (n = 3), from the rectum to the descending colon (n = 7), and up to the transverse colon (n = 1). The most common barium enema finding of milk allergy in infants was spasm of the distal colon. The other findings were a transitional zone, a reversed rectosigmoid index, mucosal irregularity and barium retention

  13. Synthesis of double perxenate of lanthanum and barium

    International Nuclear Information System (INIS)

    Synthesis of double perxenate of lanthanum and barium on the basis of sodium perxenate and lanthanum and barium acetates, is described. The obtained compound is characterized by means of element analysis, x-ray-electron-, IR- and RS-spectroscopy. Its thermal stability and water solubility are determined

  14. BARIUM IN TEETH AS INDICATOR OF BODY BURDEN

    Science.gov (United States)

    A study was conducted to determine the biological availability of naturally occurring barium in a municipal drinking water by the analysis of barium in deciduous teeth of children. The grade school children of two Illinois towns were chosen for the study. The towns were chosen ba...

  15. Colour centres in barium hexaaluminate (phase I)

    International Nuclear Information System (INIS)

    Colour centres produced by X-ray irradiation of barium hexaaluminate (phase I) with β-alumina structure are studied by electron paramagnetic resonance, optical absorption, and thermally stimulated luminescence. It is shown that in addition to the F+ centres characteristic of β-alumina phases, this compound presents other colour centres such as F, O-, and possibly V-type centres. The stability of these defects is investigated by means of thermal bleaching experiments and thermally stimulated luminescence. An alternative model to the generally accepted one is proposed, for the F+ centres, together with a mechanism of defect formation. (author)

  16. Short-cavity squeezing in barium

    Science.gov (United States)

    Hope, D. M.; Bachor, H-A.; Manson, P. J.; Mcclelland, D. E.

    1992-01-01

    Broadband phase sensitive noise and squeezing were experimentally observed in a system of barium atoms interacting with a single mode of a short optical cavity. Squeezing of 13 +/- 3 percent was observed. A maximum possible squeezing of 45 +/- 8 percent could be inferred for out experimental conditions, after correction for measured loss factors. Noise reductions below the quantum limit were found over a range of detection frequencies 60-170 MHz and were best for high cavity transmission and large optical depths. The amount of squeezing observed is consistent with theoretical predictions from a full quantum statistical model of the system.

  17. Duodenal diverticula demonstrated by barium examination

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, T.; Thommesen, P.

    An investigation for biliary tract calculi and food-stimulated gastro-oesophageal reflux was carried out in 37 patients with duodenal diverticula demonstrated by barium examination. Sixty per cent of the diverticula were located in the descending part of the duodenum. Biliary tract calculi were demonstrated in 38 per cent and food-stimulated gastro-oesophageal reflux in 81 per cent of the patients. The detection of a duodenal diverticulum should result in a supplementary investigation for gallstones and gastrooesophageal reflux and its sequelae.

  18. Barium dithionate as an EPR dosemeter.

    Science.gov (United States)

    Baran, M P; Bugay, O A; Kolesnik, S P; Maksimenko, V M; Teslenko, V V; Petrenko, T L; Desrosiers, M F

    2006-01-01

    Electron paramagnetic resonance (EPR) dosimetry is growing in popularity and this success has encouraged the search for other dosimetric materials. Previous studies of gamma-irradiated barium dithionate (BaS(2)O(6) x 2H(2)O) have shown promise for its use as a radiation dosemeter. This work studies in greater detail several essential attributes of the system. Special attention has been directed to the study of EPR response dependences on microwave power, irradiation temperature, minimum detectable dose and post-irradiation stability. PMID:16565205

  19. Scattering lengths of calcium and barium isotopes

    OpenAIRE

    Dammalapati, U.; Willmann, L.; Knoop, S.

    2011-01-01

    We have calculated the s-wave scattering length of all the even isotopes of calcium (Ca) and barium (Ba), in order to investigate the prospect of Bose-Einstein condensation (BEC). For Ca we have used an accurate molecular potential based on detailed spectroscopic data. Our calculations show that Ca does not provide other isotopes alternative to the recently Bose condensed 40Ca that suffers strong losses because of a very large scattering length. For Ba we show by using a model potential that ...

  20. Accuracy of radiographer plain radiograph reporting in clinical practice: a meta-analysis

    International Nuclear Information System (INIS)

    AIM: To determine the accuracy of radiographer plain radiograph reporting in clinical practice. MATERIALS AND METHODS: Studies were identified from electronic sources and by hand searching journals, personal communication and checking reference lists. Eligible studies assessed radiographers' plain radiograph reporting in clinical practice compared with a reference standard, and provided accuracy data to construct 2x2 contingency tables. Data were extracted on study eligibility and characteristics, quality and accuracy. Summary estimates of sensitivity and specificity and receiver operating characteristic curves were used to pool the accuracy data. RESULTS: Radiographers compared with a reference standard, report plain radiographs in clinical practice at 92.6% and 97.7% sensitivity and specificity, respectively. Studies that compared selectively trained radiographers and radiologists of varying seniority against a reference standard showed no evidence of a difference between radiographer and radiologist reporting accuracy of accident and emergency plain radiographs. Selectively trained radiographers were also found to report such radiographs as accurately as those not solely from accident and emergency, although some variation in reporting accuracy was found for different body areas. Training radiographers improved their accuracy when reporting normal radiographs. CONCLUSION: This study systematically synthesizes the literature to provide an evidence-base showing that radiographers can accurately report plain radiographs in clinical practice

  1. Radiographic instrumentation for DPM experiments

    Science.gov (United States)

    Fripp, Archie L.; Debnam, W. J.; Simchick, Richard T.; Barber, P. G.

    1990-01-01

    New developments in x-ray radiography that may be applicable to containerless experimentation are presented. The two features discussed are the use of radiography to determine the position and shape of the solid-liquid interface and, with the aid of appropriate markers, the flow patterns in either the surface or bulk of the liquid state. Both surface energy and fluid viscosity measurements can be made with the aid of the described radiographic system.

  2. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  3. HADES, A Radiographic Simulation Code

    Energy Technology Data Exchange (ETDEWEB)

    Aufderheide, M.B.; Slone, D.M.; Schach von Wittenau, A.E.

    2000-08-18

    We describe features of the HADES radiographic simulation code. We begin with a discussion of why it is useful to simulate transmission radiography. The capabilities of HADES are described, followed by an application of HADES to a dynamic experiment recently performed at the Los Alamos Neutron Science Center. We describe quantitative comparisons between experimental data and HADES simulations using a copper step wedge. We conclude with a short discussion of future work planned for HADES.

  4. Barium cardiotoxicity: Relationship between ultrastructural damage and mechanical effects.

    Science.gov (United States)

    Delfino, G; Amerini, S; Mugelli, A

    1988-01-01

    The ultrastructural damage in guinea-pig ventricular strips caused by barium was analysed. At a concentration of 1 mmol/litre, barium chloride caused a dramatic increase in the developed tension associated with the onset of automaticity. The ultrastructural analysis demonstrated that barium caused notable and consistent alterations which affected most myocyte components. Various degenerative aspects were observed in mitochondria and in the contractile apparatus. Glycogen deposits were completely depleted. Preparations driven at 4 Hz (i.e. the rate of spontaneous firing of barium-treated preparations) showed moderate ultrastructural alterations, thus demonstrating that the increase in the rate of beating is not the only determinant of the observed damage. These results suggest that the myocardial toxicity of barium is due not only to the well-known modifications in membrane permeability, but possibly also to alterations in cell function. PMID:20702358

  5. Barium and radium migration in unconsolidated Canadian geological materials

    International Nuclear Information System (INIS)

    This report describes the results of laboratory studies on the distribution coefficients of radium and barium in samples of unconsolidated geologic materials. Graphs of Ksub(d) versus solution concentration for the respective elements showed constant Ksub(d) values in the low concentration range suggesting that, at low concentrations, a distribution coefficient is a valid means of representing the geochemical reactions of both barium and radium. The Ksub(d) values for barium range between 60 and 3500 ml/g. The values appear to be influenced by the amount of barium occurring naturally in the soil materials and thus there is little possiblility of using barium as an analog of radium in laboratory experiments. The Ksub(d) values of radium vary from 50 to 1000 ml/g indicating that a wide range of geological materials have a substantial capacity to retard the migration of radium

  6. A Radiographic Study of Odontoma

    International Nuclear Information System (INIS)

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows ; 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  7. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  8. Radiographic quality: Control and evaluation

    International Nuclear Information System (INIS)

    The control and evaluation of radiographic quality vary considerably from institution to institution, and this has resulted in increased government legislation in most jurisdictions, which attempts to provide some measure of uniformity in standards of equipment installation, maintenance, and use. Where legislation is not yet in place, it is pending, so that all facilities using x-radiation are, or soon will be, legally bound to operate within accepted guidelines. These guidelines are established to provide the radiologist with radiographs of optimum diagnostic quality while keeping the radiation dose to the patient and radiology personnel as low as possible. There are many excellent publications that provide detailed step-by-step instructions on each facet of radiographic quality control; these procedures will, therefore, not be covered in detail here. The following information may, however, be of interest as it relates primarily to pediatric radiography and will prove useful to those initiating quality control and evaluation programs; it is important that priorities be established - the necessary steps are listed below

  9. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  10. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 109 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author)

  11. Rib fracture: Different radiographic projections

    International Nuclear Information System (INIS)

    Rib fracture is the most common thoracic injury. It is thought to be present in 10% of all traumatic injuries and in almost 40% of patients who sustained severe non-penetrating trauma. There are 12 pairs of ribs. This study reviews various methods of acquisition and reconstruction of radiographic images of traumatic rib fractures in order to determine the optimal views and to simplify rib fracture diagnostics. Eight different plain radiography pictures of ribs were performed with the patient in an erect position. The following projections were obtained in sequence: oblique at 45° or 30° angle on inspiration, oblique at 45° or 30° angle on expiration as well as 45° and 39° projections during slow and fast breathing. All radiographic examinations were performed using a Philips three-phase scanner installed at the Al- Razi Hospital in Jenin, Palestine. The results demonstrate that the 45° antero-posterior oblique projection performed on expiration is recommended for diagnostics and interpretation of traumatic rib fractures. Conclusion emerging from this study are such that for a 45° oblique view on expiration is recommended for radiographic imaging of patients with clinical signs of fracture, e.g. evaluation of lower rib fractures, while 45° oblique view during fast breathing is recommended for suspected upper rib fractures

  12. Automating the radiographic ndt process

    International Nuclear Information System (INIS)

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justification for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 109 bits per 14 x 17. This is equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 inch film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in separate parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system

  13. The Novel Formation of Barium Titanate Nanodendrites

    Directory of Open Access Journals (Sweden)

    Chien-Jung Huang

    2014-01-01

    Full Text Available The barium titanate (BaTiO3 nanoparticles with novel dendrite-like structures have been successfully fabricated via a simple coprecipitation method, the so-called BaTiO3 nanodendrites (BTNDs. This method was remarkable, fast, simple, and scalable. The growth solution is prepared by barium chloride (BaCl2, titanium tetrachloride (TiCl4, and oxalic acid. The shape and size of BaTiO3 depend on the amount of added BaCl2 solvent. To investigate the influence of amount of BaCl2 on BTNDs, the amount of BaCl2 was varied in the range from 3 to 6 mL. The role of BaCl2 is found to have remarkable influence on the morphology, crystallite size, and formation of dendrite-like structures. The thickness and length of the central stem of BTND were ~300 nm and ~20 μm, respectively. The branchings were found to occur at irregular intervals along the main stem. Besides, the formation mechanism of BTND is proposed and discussed.

  14. High resolution studies of barium Rydberg states

    International Nuclear Information System (INIS)

    The subtle structure of Rydberg states of barium with orbital angular momentum 0, 1, 2 and 3 is investigated. Some aspects of atomic theory for a configuration with two valence electrons are reviewed. The Multi Channel Quantum Defect Theory (MQDT) is concisely introduced as a convenient way to describe interactions between Rydberg series. Three high-resolution UV studies are presented. The first two, presenting results on a transition in indium and europium serve as an illustration of the frequency doubling technique. The third study is of hyperfine structure and isotope shifts in low-lying p states in Sr and Ba. An extensive study of the 6snp and 6snf Rydberg states of barium is presented with particular emphasis on the 6snf states. It is shown that the level structure cannot be fully explained with the model introduced earlier. Rather an effective two-body spin-orbit interaction has to be introduced to account for the observed splittings, illustrating that high resolution studies on Rydberg states offer an unique opportunity to determine the importance of such effects. Finally, the 6sns and 6snd series are considered. The hyperfine induced isotope shift in the simple excitation spectra to 6sns 1S0 is discussed and attention is paid to series perturbers. It is shown that level mixing parameters can easily be extracted from the experimental data. (Auth.)

  15. NANOSCALE BARIUM HYDROSILICATES: CHOOSING THE SYNTHESIS TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    GRISHINA Anna Nikolaevna

    2013-08-01

    Full Text Available Cement concretes are the most used materials in modern civil engineering. Due to that such materials draw great attention both in the Russian Federation and abroad. The possibility to enhance the manufacturability and operational properties of concretes results in significant reduction of overall operating costs. Many enhancement methods have been elaborated. Among them there is one based on introduction of calcium hydrosilicates into construction composition. The authors set up a hypothesis that similarity between properties and structures of different hydrosilicates (for example, alkaline earth metals and metals of the second group will provide similar increased operational characteristics. The specialists of Research and Educational Center «Nanotechnology» are developing cement composites nanomodification methods which include introduction of nanodimensional barium hydrosilicates particles. The synthesis of barium hydrosilicates particles can be done with the use of many technologies, different by energy consumption or performing complexity. Taking into account both these factors, one can assume that low-temperature sol-gel synthesis from diluted water solutions is the proper technology. The present paper shows that this assumption is correct. The selection of certain technology is made by the means of multiobjective optimization, which is in turn is performed by the means of linear scalarization. This method, while not always giving the Pareto optimal solutions, can be easily implemented. The particle size distribution is taken into consideration during selection of objectives and weights. It is shown that selected technology allows manufacturing nanoparticles with median size about 30 nm.

  16. Coprecipitation of europium with barium sulphate

    International Nuclear Information System (INIS)

    The distribution behaviour of the trivalent europium ion at a micro-component scale, between barium sulphate and aqueous solution, was studied at ambient temperature. Experiments were carried out using radioactive tracers. Results indicate an enrichment of the micro component in the solid phase relative to the solution. The effects of the concentrations of the micro and macro-elements on the coprecipitation have been examined. Europium distribution coefficient DEu increases from 1.1 ± 0.2 to 3.2 ± 0.4 when initial europium concentration decreases from more than 17 x 10-5 to 1.4 x 10-5 M, in sulphuric media with SO42- in excess or CBa2+/CSO42- Eu. The coprecipitation of europium with barium sulphate as a heterovalent solid-solution is described by heterogeneous model obeying the Doerner and Hoskins logarithmic partition law. The weaker partition coefficients lower than unity (λ = 0.25 when CEu(III) ∼ 1.4 x 10-5 M and λ = 0.13 when CBa2+/CSO42- -5 ≤ CEu(III) = 153.5 x 10-5 M) lead to crystals increasingly enriched in the trace element. (orig.)

  17. Photon attenuation characteristics of barium enriched cement

    International Nuclear Information System (INIS)

    Nuclear radiations are widely used in several applications of nuclear sciences, medicine and industry. In the design and construction of installations housing high intensity radioactive sources and other radiation generating equipment, a variety of shielding materials are used to minimise the exposure to the individuals. Among the materials used, lead is best known for radiation shielding due to its high density and atomic number. However, in construction of radiation facilities, lead in the form of bricks or slabs cannot be substituted for cement as building material. As an alternative, barium enriched cement, which apart from better compressive strength, smoother surface finish and high abrasive resistance, offers adequate shielding to gamma radiations. In the present work, attenuation properties of commercial as well as barium enriched cements have been studied and compared with that of lead for photons of 662 and 1250 keV emitted from 137Cs and 60Co, respectively. Although photon attenuation data can be obtained by mixture rule theoretically, it is necessary to determine this data experimentally before use

  18. Use of mucolytic agents and guaran HEPART (HP-7000) for the detection of mucosal villi in double contrast barium studies of the small intestine

    International Nuclear Information System (INIS)

    It was the aim of this study to enhance the visualisation of mucosal villi by double contrast barium studies of the small bowel. Prior to the radiological examination a 2-day pretreatment with the mucolytic agents acetylcysteine or carbocisteine was effected. Double contrast studies were performed with a high-molecular fraction of guaran HEPART (HP-7000), a hydrocolloidal isolated from the seed endosperm of C. tetragonolobus added into contrast-medium and distention medium. Compared to double contrast studies without mucolytic therapy, this procedure results in a better transparency and demonstration of the mucosal villi shown by a granular pattern in the radiographs. High quality visualisation of intestinal villi was achieved in all patients studied. A 2-day pretreatment with carbocisteine or acetylcysteine and the use of guaran in the double contrast barium study of the small bowel results in a greatly enhanced visualisation of mucosal villi. (orig.)

  19. Radiographic assessment of laryngeal reflexes in ketamine-anesthetized cats

    International Nuclear Information System (INIS)

    The competence of the laryngeal closure reflexes of cats anesthetized with ketamine was assessed. Radiographic evaluations of the respiratory and digestive tracts were made after colloidal barium suspension was instilled into the pharynges of conscious and ketamine-anesthetized cats. There was a significant ketamine dose-related response of spread of contrast medium into the supraglottic laryngeal area and into the stomach 2 minutes after contrast medium was instilled into the pharynx (P less than 0.05). Cats did not aspirate contrast medium into the lower respiratory tract. Three ketamine-anesthetized cats aspirated contrast medium into the subglottic area of the larynx, and 2 of these cats also aspirated the material into the cranial part of the trachea. This material was coughed up and swallowed within 5 minutes. Transit time of contrast medium into the stomach seemed to be increased in 11 of the 15 cats given the larger dosages of ketamine (24, 36, 48 mg/kg of body weight), compared with that in conscious cats and those given ketamine at 12 mg/kg. Competent laryngeal protective reflexes in cats can be maintained with ketamine anesthesia. Contrast radiography could be used as a diagnostic aid in ketamine-anesthetized cats suspected of laryngeal reflex abnormalities

  20. Do all barium stars have a white dwarf companion?

    Science.gov (United States)

    Dominy, J. F.; Lambert, D. L.

    1983-01-01

    International Ultraviolet Explorer short-wavelength, low-dispersion spectra were analyzed for four barium, two mild barium, and one R-type carbon star in order to test the hypothesis that the barium and related giants are produced by mass transfer from a companion now present as a white dwarf. An earlier tentative identification of a white dwarf companion to the mild barium star Zeta Cyg is confirmed. For the other stars, no ultraviolet excess attributable to a white dwarf is seen. Limits are set on the bolometric magnitude and age of a possible white dwarf companion. Since the barium stars do not have obvious progenitors among main-sequence and subgiant stars, mass transfer must be presumed to occur when the mass-gaining star is already on the giant branch. This restriction, and the white dwarf's minimum age, which is greater than 8 x 10 to the 8th yr, determined for several stars, effectively eliminates the hypothesis that mass transfer from an asymptotic giant branch star creates a barium star. Speculations are presented on alternative methods of producing a barium star in a binary system.

  1. Designed microstructures in textured barium hexaferrite

    Science.gov (United States)

    Hovis, David Brian

    It is a fundamental principle of materials science that the microstructure of a material defines its properties and ultimately its performance for a given application. A prime example of this can be found in the large conch shell Strombus gigas, which has an intricate microstructure extending across five distinct length scales. This microstructure gives extraordinary damage tolerance to the shell. The structure of Strombus gigas cannot be replicated in a modern engineering ceramic with any existing processing technique, so new processing techniques must be developed to apply this structure to a model material. Barium hexaferrite was chosen as a model material to create microstructures reminiscent of Strombus gigas and evaluate its structure-property relations. This work describes novel processing methods to produce textured barium hexaferrite with no coupling between the sample geometry and the texture direction. This technique, combining magnetic field-assisted gelcasting with templated grain growth, also allows multilayer samples to be fabricated with different texture directions in adjacent layers. The effects of adding either B2O3 or excess BaCO 3 on the densification and grain growth of barium hexaferrite was studied. The texture produced using this technique was assessed using orientation imaging microscopy (OIM) at Oak Ridge National Laboratory. These measurements showed peak textures as high as 60 MRD and sharp interfaces between layers cast with different texture directions. The effect of oxygen on the quality of gelcasting is also discussed, and it is shown that with proper mold design, it is possible to gelcast multiple layers with differing texture directions without delamination. Monolithic and multilayer samples were produced and tested in four point bending to measure the strength and work of fracture. Modulus measurements, made with the ultrasonic pulse-echo technique, show clear signs of microcracking in both the isotropic and textured samples

  2. [Allergy to radiographic contrast media].

    Science.gov (United States)

    Vionnet, Julien; Petitpierre, Stéphanie; Fumeaux, Alexandre; Meuli, Reto; Spertini, Francois; Comte, Denis

    2013-04-17

    Allergy to radiographic contrast media Hypersensitivity reactions to radio-contrast media are common in the daily practice. These products are responsible for immediate ( 1 hour after administration) hypersensitivity reactions. A diagnostic work-up by an allergologist with skin tests and in some cases provocation tests is of value in reducing the risk of recurrent hypersensitivity reactions to iodinated contrast media. A careful selection of the patients is required because the incidence of breakthrough reactions is still concerning, even with proper premedication. Practical recommendations are presented in this article. For gadolinium-based contrast agents, data in the literature is not sufficient for suggesting guidelines. PMID:23667970

  3. Chemical composition of Eu2+ luminescence in the barium hexaaluminates

    International Nuclear Information System (INIS)

    This paper consists of two parts. In the first part the chemical composition of two kinds of barium hexaaluminate (one poor and one rich in barium) is explained using the local electroneutrality concept. In the second part a reinvestigation of the Eu2+ luminescence in these compounds is reported. The emission spectrum of each of the two compounds shows a blue and a green emission bank. The blue emission bank is ascribed to Eu2+ ions at barium sites, whereas the green emission band is identified with Eu2+ ions incorporated at aluminum sites within spinel blocks of the structure

  4. Magic Wavelength of an Optical Clock Transition of Barium

    International Nuclear Information System (INIS)

    Similar to most of the other alkaline earth elements, barium atoms can be candidates for optical clocks, thus the magic wavelength for an optical lattice is important for the clock transition. We calculate the magic wavelength of a possible clock transition between 6s21S0 and 6s5d3 D2 states of barium atoms. Our theoretical result shows that there are three magic wavelengths 615.9nm, 641.2nm and 678.8nm for a linearly polarized optical lattice laser for barium. (atomic and molecular physics)

  5. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  6. Performance evaluation of radiographic systems and techniques

    International Nuclear Information System (INIS)

    The chapter describes the present status of the problem of evaluating the imaging performance of a radiographic channel as a whole including the last stage which is psychophysical. Reference is made to specific detail shapes and to the extensive practive of using artificial details to monitor radiographic quality. Performance indices derived using informational concepts are discussed. A closing discussion points out suggested ways for mproving radiographic imaging

  7. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  8. Reference Neutron Radiographs of Nuclear Reactor Fuel

    OpenAIRE

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as...

  9. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  10. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  11. Early radiographic changes in radiation bone injury

    International Nuclear Information System (INIS)

    A chronologic series of periapical radiographs was evaluated for the purpose of detecting damage to bone and tooth-supporting tissues in a patient receiving radiation therapy for a basal cell carcinoma of the mandibular gingiva. Widening of the periodontal space was one of the early radiographic changes observed. It is suggested, from the sequence of radiographic changes, that radiation-induced changed in the circulatory system of the bone might be primarily responsible for the resulting changes

  12. Clinical Applications of Successive Spot Radiographs in Esophagography for Diagnosing the Early Esophageal Cancer

    Institute of Scientific and Technical Information of China (English)

    TANGLi-jun; KONGFan-fu; WANGDe-hang

    2004-01-01

    To introduce primary experience of clinical applications of successive spot radiographs in esophagography for the din mlosis of early esoplmgeal cancer (EEC). Methods: Six patients with EEC were examined and doagnosed dlaarmsed by a digital X-ray machine. According to the routine double contrast study of esophagus, the patient gulped a barimn suspension in the upright position when the successive films were taken by 2 frmnes per second lasting for about 10 seconds. Various phases were obtained including barimn-filled views,mucosal relief views and double contrast views. Results: Functional changes and abnormal mucosal folds of esophagus were present on successive spot radiographs of esophagography in patients with EEC and those patients with EEC were confirmed by endoscopic and pathologic findings. Four patients had mild loss of distensibility, 2 patients had spasmodic contraction and 1 patient had barium retention. Thickened or interrupted folds were found in all cases.Little niches were detected in 5 of 6 patients. Conctusion: Evidence presented in barimn studies of esophagus is more comprehensive and intact for the diagnosis of EEC when successive spot radiographs are employed. Functional changes of esophagus are more evident with this approach.

  13. A novel barium polymeric membrane sensor for selective determination of barium and sulphate ions based on the complex ion associate barium(II)-Rose Bengal as neutral ionophore

    Energy Technology Data Exchange (ETDEWEB)

    Othman, A.M. [Genetic Engineering and Biotechnology Research Institute (GEBRI), Minufiya University, Sadat City (Egypt); El-Shahawi, M.S. [Chemistry Department, Faculty of Science at Damiatta, Mansoura University, Damiatta, Dumyat 34517 (Egypt)]. E-mail: mohammad_el_shahawi@yahoo.co.uk; Abdel-Azeem, M. [Chemistry Department, Faculty of Science at Damiatta, Mansoura University, Damiatta, Dumyat 34517 (Egypt)

    2006-01-12

    A simple, long life, rapid response and sensitive barium(II)-PVC membrane sensor that typically follows Nernstian behavior has been developed for the assay of barium(II) ions. The developed sensor has been made by incorporating the complex ion associate of barium(II)-Rose Bengal (Ba-RB) as an ionophore into a plasticized PVC matrix. The sensor is stable and exhibited fast potential response of 20 s and gave a good linear response with a Nernstian slope of 28.5 {+-} 0.4 mV/decade of activity within the concentration range 5 x 10{sup -5} to 10{sup -1} M over a wide range of pH 4.5-10.0 for barium(II) ions. The developed sensor showed comparatively good selectivity for barium(II) ions with respect to other alkali, alkaline earth, transition and heavy metal ions. The plasticizer o-nitrophenyloctyl ether controlled significantly the calibration slope and the lifetime of the fabricated sensor. The proposed sensor was used successfully for the analysis of barium(II) ions in wastewater samples and in lithophone pigment with excellent recovery percentages in the range 98.9-99.8 {+-} 1.6%. The determination of sulphate in fresh and potable water samples with the developed sensor has been also achieved successfully. The described sensor provides a reliable means with good correlation with the data obtained by atomic absorption spectrometry (AAS) and other spectrophotometric methods for the analysis of trace amounts of barium(II) and/or sulphate ions in different matrices.

  14. A novel barium polymeric membrane sensor for selective determination of barium and sulphate ions based on the complex ion associate barium(II)-Rose Bengal as neutral ionophore

    International Nuclear Information System (INIS)

    A simple, long life, rapid response and sensitive barium(II)-PVC membrane sensor that typically follows Nernstian behavior has been developed for the assay of barium(II) ions. The developed sensor has been made by incorporating the complex ion associate of barium(II)-Rose Bengal (Ba-RB) as an ionophore into a plasticized PVC matrix. The sensor is stable and exhibited fast potential response of 20 s and gave a good linear response with a Nernstian slope of 28.5 ± 0.4 mV/decade of activity within the concentration range 5 x 10-5 to 10-1 M over a wide range of pH 4.5-10.0 for barium(II) ions. The developed sensor showed comparatively good selectivity for barium(II) ions with respect to other alkali, alkaline earth, transition and heavy metal ions. The plasticizer o-nitrophenyloctyl ether controlled significantly the calibration slope and the lifetime of the fabricated sensor. The proposed sensor was used successfully for the analysis of barium(II) ions in wastewater samples and in lithophone pigment with excellent recovery percentages in the range 98.9-99.8 ± 1.6%. The determination of sulphate in fresh and potable water samples with the developed sensor has been also achieved successfully. The described sensor provides a reliable means with good correlation with the data obtained by atomic absorption spectrometry (AAS) and other spectrophotometric methods for the analysis of trace amounts of barium(II) and/or sulphate ions in different matrices

  15. Theoretical isotope shifts in neutral barium

    CERN Document Server

    Nazé, Cédric; Godefroid, Michel

    2015-01-01

    The present work deals with a set of problems in isotope shifts of neutral barium spectral lines. Some well known transitions ($6s^2~^1S_0-6s6p~^{1,3}P^o_1$ and $6s^2~^1S_0-6p^2~^3P_0$) are first investigated. Values of the changes in the nuclear mean-square charge radius are deduced from the available experimental isotope shifts using our ab initio electronic factors. The three sets $\\{ \\delta\\langle r^2\\rangle^{A,A'}\\} $ obtained from these lines are consistent with each other. The combination of the available nuclear mean-square radii with our electronic factors for the $6s5d~^3D_{1,2} -6s6p~^{1}P^o_1$ transitions produces isotope shift values in conflict with the laser spectroscopy measurements of Dammalapati et al. (Eur. Phys. J. D 53, 1 (2009)).

  16. Chemical abundance analysis of 19 barium stars

    CERN Document Server

    Yang, G C; Spite, M; Chen, Y Q; Zhao, G; Zhang, B; Liu, G Q; Liu, Y J; Liu, N; Deng, L C; Spite, F; Hill, V; Zhang, C X

    2016-01-01

    We aim at deriving accurate atmospheric parameters and chemical abundances of 19 barium (Ba) stars, including both strong and mild Ba stars, based on the high signal-to-noise ratio and high resolution Echelle spectra obtained from the 2.16 m telescope at Xinglong station of National Astronomical Observatories, Chinese Academy of Sciences. The chemical abundances of the sample stars were obtained from an LTE, plane-parallel and line-blanketed atmospheric model by inputting the atmospheric parameters (effective temperatures, surface gravities, metallicity and microturbulent velocity) and equivalent widths of stellar absorption lines. These samples of Ba stars are giants indicated by atmospheric parameters, metallicities and kinematic analysis about UVW velocity. Chemical abundances of 17 elements were obtained for these Ba stars. Their light elements (O, Na, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn and Ni) are similar to the solar abundances. Our samples of Ba stars show obvious overabundances of neutron-capture (n-ca...

  17. Analysis of europium doped luminescent barium thioaluminate

    Institute of Scientific and Technical Information of China (English)

    张东璞; 喻志农; 薛唯; 章婷; 丁瞾; 王武育

    2010-01-01

    Europium-doped barium thioaluminate sputtering target was synthesized by powder sintering method and thin film was deposited by radio frequency(RF) sputtering.X-ray diffractometer(XRD) pattern indicated that the main compound of the target was BaAl4S7.Oxygen was the main impurity which led to the formation of BaAl2O4.It was shown that both BaAl4S7 and BaAl2S4 were contained in the as-grown thin films and a 471.7 nm emission peak in the PL spectra appeared due to a combination of BaAl4S7:Eu2+ and BaAl2S4:Eu2...

  18. Barium hexaferrite ferrofluids - preparation and physical properties

    Science.gov (United States)

    Müller, R.; Hiergeist, R.; Steinmetz, H.; Ayoub, N.; Fujisaki, M.; Schüppel, W.

    1999-07-01

    Barium hexaferrite BaFe 12-2 xTi xCo xO 19 ferrofluids have been prepared for the first time using oleic acid as surfactant and Isopar M ® as carrier liquid. The initial susceptibility versus temperature for zero-field cooling of the ferrofluid was obtained by a vibrating sample magnetometer. TEM pictures of the fluid show isolated particles and only small agglomerates and a mean particle diameter of approx. 8 nm. Numerical calculations of the magneto-viscous effect, based on the local-equilibrium magnetic state model, clearly show the benefit for Ba-ferrite ferrofluids resulting from the high uniaxial anisotropy compared to magnetite ferrofluids. Rheological measurements were performed with a rotational-type viscometer with magnetic field perpendicular to the hydrodynamic vortex axis.

  19. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  20. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  1. Radar absorption properties of doped barium hexaferrite

    International Nuclear Information System (INIS)

    Full text: Since the 1950s, it has been known that barium hexaferrite exhibits a ferrimagnetic resonance at about 48 GHz. Early research was directed at finding dopants that would increase this frequency to enable the preparation of lossless waveguide components. However, more recent efforts have explored the potential of doped barium hexaferrite as a radar absorbing material in the low GHz frequency range. In particular, Nedkov et al demonstrated that partial substitution of the iron with cobalt-titanium, to give Ba(Co0.5Ti0.5)xFe11.9-xMn0.1O19 with x = 1.6, could reduce the ferrimagnetic resonance frequency to 15 GHz. The small amount of manganese was included 'to improve the dielectric properties' of the material. In this work we increased the doping to x = 2.2 to arrive at a resonance frequency of just 1.35 GHz, which lies within the operational frequency range of typical airborne early warning and control (AEWAC) radar systems. An increase in the resonance signal at this concentration is believed to be associated with the onset of a switch from axial to planar magnetocrystalline anisotropy, as reported by Kreisel et al . It is uncertain why our resonance frequency for x = 2.2 is significantly lower than the value of 2.56 GHz reported elsewhere for a Mn-free specimen with x = 2.6. Chromium was also tested as a new dopant material but proved unsuccessful in reducing the resonant frequency below 40 GHz, the upper limit of the microwave network analyser that was employed. All specimens were prepared using solid state reaction of stoichiometric amounts of oxides and carbonates, and characterised using x-ray powder diffraction and 57Fe Moessbauer spectroscopy

  2. The Karlsruhe 4π barium fluoride detector

    International Nuclear Information System (INIS)

    A new experimental approach has been implemented for accurate measurements of neutron capture cross sections in the energy range from 5 to 200 keV. The Karlsruhe 4π Barium Fluoride Detector consists of 42 crystals shaped as hexagonal and pentagonal truncated pyramids forming a spherical shell with 10 cm inner radius and 15 cm thickness. All crystals are supplied with reflector and photomultiplier, thus representing independent gamma-ray detectors. Each detector module covers the same solid angle with respect to a gamma-ray source located in the centre. The energy resolution of the 4π detector is 14% at 662 keV and 7% at 2.5 MeV gamma-ray energy, the overall time reslution is 500 ps and the peak efficiency 90% at 1 MeV. The detector allows to register capture cascades with 95% probability above a threshold energy of 2.5 MeV in the sum energy spectrum. Neutrons are produced via the 7Li(p,n)7Be reaction using the pulsed proton beam of a Van de Graaff accelerator. The neutron spectrum can be taylored according to the experimental requirements in an energy range from 5 to 200 keV by choosing appropriate proton energies. A collimated neutron beam is passing through the detector and hits the sample in the centre. The energy of captured neutrons is determined via time of flight, the primary flight path being 77 cm. The combination of short primary flight path, a 10 cm inner radius of the spherical BaF2 shell, and the low capture cross section of barium allows to discriminate background due to capture of sample scattered neutrons in the scintillator by time of flight, leaving part of the neutron energy range completely undisturbed. (orig./HSI)

  3. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de; Ewert, Uwe, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de; Müller, Christina, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de [Federal Institute for Materials Testing and Research, Berlin (Germany); Pitkänen, Jorma, E-mail: jorma.pitkanen@posiva.fi [Posiva Oy, Eurajoki (Finland)

    2015-03-31

    The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors.

  4. Gastric tumors on chest radiographs

    International Nuclear Information System (INIS)

    Gastric neoplasms of three patients protruded into their gas-containing fornices and were first visualized on plain chest radiographs. Endoscopy and/or surgery confirmed these to be a polyp, a leiomyoma, and an adenocarcinoma. The polyp, 1.3 cm in diameter, was the smallest of these three, but smaller lesions may be detectable under suitable conditions. Adequate technique and positioning, sufficiently large lesions in the upper portion of the stomach, a central beam tangential to the tumor, sufficient gas in the stomach, and careful scrutiny by the observer are required. Lesions may be more readily visualized during chest radiography when oral sodium bicarbonate is used to distend the stomach. In chest radiography, exposure limited to the lung fields has been advocated for economy and dose reduction. However, too small an exposure field may result in loss of information potentially beneficial to the patient. Using the smaller of two popular film sizes (35 x 43 cm and 35 x 35 cm), the saving in surface and bone marrow doses is negligible, and the saving in gonad dose may be nil over that when shielding is used. The interest of the observer may be absorbed by a concomitant cardiac or pulmonary lesion. Careful scrutiny of the entire radiograph is therefore essential. (author)

  5. Observer POD for radiographic testing

    International Nuclear Information System (INIS)

    The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors

  6. Stepped scanner radiographic imaging system

    International Nuclear Information System (INIS)

    The imaging system includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals of each radiographic event. The position of the bed relative to the camera is altered sequentially by drive means, between each of a sequence of images provided by the camera. The sequentially occurring images are presented on the display system, each image being positioned on the display in correspondence with the location of the bed relative to the camera. The coordinates of each image point presented on the display is equal to the sum of the respective X and Y coordinate signals from the camera with X and Y coordinate signals provided by a timer which controls the drive means and defines the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. (author)

  7. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Automation, the removal of the human element in inspection has not been generally applied to film radiographic NDT. The justification for automation is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 3x10 (to the power of nine) bits per 14x17. This is equivalent to 2200 computer floppy disks parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, a computer aided interpretation appears on the horizon. A unit which laser scans a 14x27 (inch) film in 6-8 seconds can digitize film in information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for film digital radiography system) is moving toward 50 micron (16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. (Author). 4 refs.; 21 figs

  8. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  9. Prognostic radiographic aspects of spondylolisthesis

    International Nuclear Information System (INIS)

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films frompatients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping. (orig.)

  10. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    OpenAIRE

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were ...

  11. Upper gastrointestinal barium evaluation of duodenal pathology: A pictorial review

    Institute of Scientific and Technical Information of China (English)

    Pankaj; Gupta; Uma; Debi; Saroj; Kant; Sinha; Kaushal; Kishor

    2014-01-01

    Like other parts of the gastrointestinal tract(GIT), duodenum is subject to a variety of lesions both congenital and acquired. However, unlike other parts of the GIT viz. esophagus, rest of the small intestine and large intestine, barium evaluation of duodenal lesions is technically more challenging and hence not frequently reported. With significant advances in computed tomography technology, a thorough evaluation including intraluminal, mural and extramural is feasible in a single non-invasive examination. Notwithstanding, barium evaluation still remains the initial and sometimes the only imaging study in several parts of the world. Hence,a thorough acquaintance with the morphology of various duodenal lesions on upper gastrointestinal barium examination is essential in guiding further evaluation. We reviewed our experience with various common and uncommon barium findings in duodenal abnormalities.

  12. Liquid-phase-deposited barium titanate thin films on silicon

    International Nuclear Information System (INIS)

    Using a mixture of hexafluorotitanic acid, barium nitrate and boric acid, high refractive index (1.54) barium titanate films can be deposited on silicon substrates. The deposited barium titanate films have featureless surfaces. The deposition temperature is near room temperature (800C). However, there are many fluorine and silicon incorporations in the films. The refractive index of the as-deposited film is 1.54. By current-voltage measurement, the leakage current of the as-deposited film with a thickness of 1000 A is about 9.48x10-7 A cm-2 at the electrical field intensity of 0.3 MV cm-1. By capacitance-voltage measurement, the effective oxide charge of the liquid-phase-deposited barium titanate film is 3.06x1011 cm-2 and the static dielectric constant is about 22. (author)

  13. Synthesis, photoluminescence and magnetic properties of barium vanadate nanoflowers

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jing [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China); Chongqing University of Science and Technology, Chongqing 401331 (China); Hu, Chenguo, E-mail: hucg@cqu.edu.cn [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China); Xi, Yi [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China); Peng, Chen [School of Physical Science and Technology, Southwest University, Chongqing 400715 (China); Wan, Buyong; He, Xiaoshan [Department of Applied Physics, Chongqing University, 174 Shapingba Street, Chongqing 400044 (China)

    2011-06-15

    Graphical abstract: The flower-shaped barium vanadate was obtained for the first time. The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. Research highlights: {yields} In the paper, the flower-shaped barium vanadate were obtained for the first time. The CHM method used here is new and simple for preparation of barium vanadate. {yields} The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. The strong bluish-green emission was observed. {yields} The ferromagnetic behavior of the barium vanadate nanoflowers was found with saturation magnetization of about 83.50 x 10{sup -3} emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10{sup -3} emu/g. {yields} The mechanisms of PL and magnetic property of barium vanadate nanoflowers have been discussed. -- Abstract: The flower-shaped barium vanadate has been obtained by the composite hydroxide mediated (CHM) method from V{sub 2}O{sub 5} and BaCl{sub 2} at 200 {sup o}C for 13 h. XRD and XPS spectrum of the as-synthesized sample indicate it is hexagonal Ba{sub 3}V{sub 2}O{sub 8} with small amount of Ba{sub 3}VO{sub 4.8} coexistence. Scan electron microscope and transmission electron microscope display that the flower-shaped crystals are composed of nanosheets with thickness of {approx}20 nm. The UV-visible spectrum shows that the barium vanadate sample has two optical gaps (3.85 eV and 3.12 eV). Photoluminescence spectrum of the barium vanadate flowers exhibits a visible light emission centered at 492 and 525 nm which might be attributed to VO{sub 4} tetrahedron with T{sub d} symmetry in Ba{sub 3}V{sub 2}O{sub 8}. The ferromagnetic behavior of the barium vanadate nanoflowers has been found with saturation magnetization of about 83.50 x 10{sup -3} emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10{sup -3} emu/g, which is mainly due to the presence of a non

  14. Lifetime Measurement for 6snp Rydberg States of Barium

    Institute of Scientific and Technical Information of China (English)

    SHEN Li; WANG Lei; YANG Hai-Feng; LIU Xiao-Jun; LIU Hong-Ping

    2011-01-01

    @@ We present a simple and efficient method for measuring the atomic lifetimes in order of tens of microseconds and demonstrate it in the lifetime determination of barium Rydberg states.This method extracts the lifetime information from the time-of-flight spectrum directly, which is much more efficient than other methods such as the time-delayed field ionization and the traditional laser induced fluorescence.The lifetimes determined with our method for barium Rydberg 6snp(n=37-59)series are well coincident with the values deduced from the absolute oscillator strengths of barium which were given in the literature [J.Phys.B 14(1981)4489, 29(1996)655]on experiments.%We present a simple and efficient method for measuring the atomic lifetimes in order of tens of microseconds and demonstrate it in the lifetime determination of barium Rydberg states. This method extracts the lifetime information from the time-of-flight spectrum directly, which is much more efficient than other methods such as the time-delayed field ionization and the traditional laser induced fluorescence. The lifetimes determined with our method for barium Rydberg 6snp (n=37-59) series are well coincident with the values deduced from the absolute oscillator strengths of barium which were given in the literature [J. Phys. B 14 (1981) 4489, 29 (1996) 655] onexperiments.

  15. 21 CFR 892.1910 - Radiographic grid.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic grid. 892.1910 Section 892.1910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1910 Radiographic grid. (a) Identification....

  16. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a)...

  17. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  18. Conversion into numerical form of radiographic images

    International Nuclear Information System (INIS)

    Radiographic means are widely used for non destructive testing. However, human and technological factors strongly influence reliability of the results and further use of these technique. Image Processing can help to overtake those difficulties if radiographic films are previously digitized. This paper shows methods and equipments used in this field. The system EDI (Enea Digital. Imagery) operating in Casaccia Energy Research Centre is described

  19. Radiographic inspection on offshore platforms

    International Nuclear Information System (INIS)

    One of the great challenges for non-destructive inspection is on offshore platforms, where safety is a critical issue. Inspection by gammagraphy is practically forbidden on the platform deck due to problems to personnel safety and radiological protection. Ir-192 sources are used and the risk of an accident with loss of radioisotope must be considered. It is unfeasible to use gammagraphy, because in case of an accident the rapid evacuation from the platform would be impossible. This problem does not occur when X-ray equipment is used as the radiation source. The limited practicality and portability of the X-ray equipment have prevented its use as a replacement for the gammagraphy. This paper presents the preliminary tests to see the viable use of radiographic tests with constant potential on offshore platforms. (author). 2 refs., 1 fig., 2 tabs, 3 photos

  20. Radiographic study of the odontoma

    International Nuclear Information System (INIS)

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  1. Radiographic study of the odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyung Kyu [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1983-11-15

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  2. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  3. Visual perception and radiographic interpretation

    International Nuclear Information System (INIS)

    Although interpretation errors are common in radiology, their causes are still debated. Perceptual mechanisms appear to be responsible for a large proportion of mistakes made by both neophytes and trained radiologists. Erroneous perception of familiar contours can be triggered by unrelated opacities. Conversely, visual information cannot induce a specific perception if the observer is not familiar with the concept represented or its radiographicappearance. Additionally, the area of acute vision is smaller than is commonly recognized. Other factors, such as the attitude, beliefs,.: preconceptions, and expectations of the viewer, can affect what he or she ''sees'' whenviewing any object, including a radiograph. Familiarity with perceptual mechanisms and the limitations of the visual system as well as multiple readings may be necessary to reduce interpretation errors

  4. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  5. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  6. Adult chest radiograph reporting by radiographers: Preliminary data from an in-house audit programme

    International Nuclear Information System (INIS)

    Aim: To examine the adult chest radiograph (CXR) reporting performance of a reporting radiographer in clinical practice using different audit systems; single radiologist and two radiologists, with clinical review of discordant cases. Materials and methods: 100 chest radiographs (CXRs) were drawn randomly from a consecutive series of 4800 CXRs which had been reported during a nine month period at a district general hospital by a radiographer after two years of training. Diagnostic outcomes were normal or abnormal, and agreement with the reporting radiographer or not. There was 50% duplication of CXRs reported between three radiologists. Concordance rates were determined for the radiographer-radiologist and inter-radiologist interpretations. Independent clinical review of discordant cases was performed to establish the final diagnosis. Results: Ninety-nine cases were reviewed, with 40 cases deemed abnormal by at least one radiologist. Consensus was found with the radiographers report in 59 normal and 33 abnormal CXRs reviewed by two radiologists (96.7% and 86.8% respectively). Seven CXR reports were discrepant with clinical review: mediastinal lymphadenopathy was missed by both radiologist and radiographer; linear atelectasis was reported by two radiologists but not the radiographer. Three cases were over-interpreted and on two occasions at least one radiologist agreed with the radiographer. There was very high concordance between the radiographer and each radiologist, 96%, 96% and 92% respectively. Conclusions: This study suggested that regular audit, which incorporates case note review and discrepant reporting within a multidisciplinary setting, should contribute to safe practice

  7. Electrooptic and piezoelectric measurements in photorefractive barium titanate and strontium barium niobate

    International Nuclear Information System (INIS)

    The authors measured the low-frequency (''unclamped'') electrooptic and piezoelectric coefficients in undoped BaTiO/sub 3/ and Sr/sub x/Ba/sub 1-x/Nb/sub 2/O/sub 6/ (chi - 0.61) crystals using interferometric techniques. The contribution of the piezoelectric effect to the Pockels measurement is discussed. For an applied ac electric field in the range 0.1-200 V/cm, the electrooptic and piezoelectric effects are linear in the magnitude of of the applied field and independent of its frequency in the range of 10 Hz-100 kHz. The unclamped electrooptic coefficients of poled BaTiO/sub 3/ single crystals are r/sub 13/ = 19.5 +- 1 pm/V and r/sub 33/ = 97 +- 7 pm/V, and for strontium barium niobate are r/sub 13/ = 47 +- 5 pm/V and r/sub 33/ = 235 +- 21 pm/V, all measured at a wavelength of 514.5 nm and at T = 230C. For the barium titanate samples the measured Pockels coefficient r/sub c/ identical to r/sub 33/ - (n/sub 1//n/sub 3/)/sup 3/r/sub 13/ = 79 +- 6 pm/V in good agreement with the value r/sub c/ = 76 +- 7 pm/V computed from the above values of r/sub 13/ and r/sub 33/, where n/sub 1/ and n/sub 3/ are the ordinary and extraordinary indexes of refraction, respectively. The measured piezoelectric coefficient is d/sub 23/ = +28.7 +- 2 pm/V for barium titanate, and is d/sub 23/ = +24.6 +- 2 pm/V for strontium barium niobate. They also measured the photoreflective coupling of two optical beams in the crystals, and they show that the dependence of the coupling strength on beam polarization is in fair agreement with the measured values of the Pockels coefficients

  8. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  9. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae; Nah, Kyung Soo [Dept. of Oral Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    1993-02-15

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  10. Magnetoresistance studies on barium doped nanocrystalline manganite

    International Nuclear Information System (INIS)

    An energetically attractive, simple, fast and a novel low temperature (300 deg. C) solution combustion route for the synthesis of crystalline and homogeneous nanoparticles of lanthanum barium manganese oxide La0.9Ba0.1MnO3+δ (LBMO) is reported. Formation and homogeneity of the solid solutions have been confirmed by powder X-ray diffraction (PXRD) and energy dispersive X-ray analysis (EDS) respectively. The Rietveld analysis shows both as-formed as well as calcined samples are in cubic phase with space group pm3m. The microstructure and agglomerated particle size of the compounds are examined by scanning electron microscope. Infrared spectroscopy revealed that both Mn-O-Mn bending mode and Mn-O stretching mode are influenced by calcination temperature. The magnetoresistance measurement on sintered LBMO pellet exhibits a broad metal-insulator transition (TM-I) at around 228 K. At 1 T applied magnetic field, LBMO shows magnetoresistance (MR) of 10%, whereas for 4 and 7 T, the negative magnetoresistance values are in the range 51 and 59% respectively at TM-I. The experimental resistivity data of the present investigation are fitted to a simple empirical equation in order to understand conduction mechanism in this compound

  11. Optical properties of calcium barium niobate

    International Nuclear Information System (INIS)

    We report on optical measurements on the novel tungsten bronze type calcium barium niobate. [001]-oriented transparent and colorless single crystals were grown by the Czochralski method with dimensions of 12 mm in diameter and about 80 mm in length. With its relatively high Curie temperature of about 538 K for the congruently melting composition of 28.1 mole% calcium and its high nonlinear coefficients, CBN is a promising material for future applications. Recent experiments revealed, that the application of an external electric field of several kV/cm to CBN at room temperature leads to an increasing opacity of the sample. This might be a drawback considering the future usability of CBN in optical systems. We present investigations on the transmittance behaviour of CBN under external electric fields, demonstrating the erasement of the clouding without affecting the polarization. Experiments have been performed at temperatures ranging from room temperature to approximately 480 K. When heating up the sample, its colorless appearance changes to a light yellow, which can be attributed to a shift of the band edge to longer wavelengths with increasing temperature. To further investigate the transmittance properties of CBN, measurements of the band edge under various temperatures up to the ferroelectric phase transition have been performed.

  12. Leachability of barium-radium sulphate sludges

    International Nuclear Information System (INIS)

    This paper presents results from the first phase of a research program designed to examine the leachability of radium-226 from barium-radium sulphate sludges. Batch leaching tests were performed. Results showed that liquid:solid contact time was relatively unimportant; radium in the sludge was stable in the presence of deionized water with a slight increase in the amount leached per gram of sludge occurring at higher liquid:solid ratios. Not unexpectedly, low and high values of leachant pH increased radium leaching. Both monovalent and divalent salt solutions also increased leaching; however, dissolved radium-226 activity levels in the leachate decreased as leachant molarity increased. For divalent salts this can be explained by the common ion effect; for monovalent salts it is opposite to results expected from solubility considerations. The interpretation of all results is complicated by the fact that in most tests, the amount of radium-226 present in the leachate was lower than the calculated contribution from the mother liquour present with the sludge. This apparent ability of the sludge to absorb radium from solution may be related to dissolution and reprecipitation of the sludge during the leaching tests

  13. Chemical compositions of four barium stars

    CERN Document Server

    Liang, Y C; Chen, Y Q; Qiu, H M; Zhang, B

    2003-01-01

    Chemical compositions of four barium stars HD 26886, HD 27271, HD 50082 and HD 98839 are studied based on high resolution, high signal-to-noise Echelle spectra. Results show that all of them are disk stars. Their \\alpha and iron peak elements are similar to the solar abundances. The neutron-capture process elements are overabundant relative to the Solar. The heavy-element abundances of the strong Ba star HD 50082 are higher than those of other three mild Ba stars. Its mass is 1.32Msun (+0.28,-0.22Msun), and is consistent with the average mass of strong Ba stars (1.5Msun). For mild Ba star HD 27271 and HD 26886, the derived masses are 1.90Msun (+0.25,-0.20Msun) and 2.78Msun (+0.75,-0.78M_sun), respectively, which are consistent with the average mass of mild Ba stars. We also calculate the theoretical abundances of Ba stars by combining the AGB stars nucleosynthesis and wind accretion formation scenario of Ba binary systems. The comparisons between the observed abundance patterns of the sample stars with the th...

  14. The diagnostic value of barium enema in acute appendicitis

    International Nuclear Information System (INIS)

    Acute appendicitis is the most common acute surgical condition of the abdomen. When the clinical presentation is atypical, barium enema has proven to be safe and useful in confirming the diagnosis and reducing the negative surgical exploration. However, the performance of barium enema in acute appendicitis has known contraindication primarily because of fear of leakage by perforation of the inflamed appendix. This study using barium enema as a diagnostic aid in acute appendicitis with atypical clinical presentation was performed to further support the previously noted efficacy and safety of this procedure. The results were as followings: 1. In case of acute appendicitis with atypical clinical presentation, the use of barium enema as a diagnostic aid increased the accuracy of diagnosis and decreased the negative surgical exploration. In women between 11 to 50 years old age, especially, it played important role differentiating appendicitis from nonsurgical acute abdomen. 2. The results of the study were 92.31% in sensitivity, 7.69% in false positive, 6.9% in false negative, and 10.26% in negative appendectomy. 3. None of case of leakage of barium by perforation of the inflamed appendix was noted, therefore, barium enema was thought to be safe as a diagnostic aid in acute appendicitis. 4. A simple partial or non filling of appendix without other associated positive finding could not exclude appendicitis, therefore, close clinical observation was necessary. 5. The positive findings of barium enema and their sensitivity were as followings: 1. Non filling of appendix: 90% 2. Partial filling of appendix: 91.7% 3. Displacement or a local impression on terminal ileum: 100%

  15. Radiographic markers - A reservoir for bacteria?

    Energy Technology Data Exchange (ETDEWEB)

    Tugwell, Jenna, E-mail: jenna.tugwell@googlemail.co [Department of Radiology, Ysbyty Gwynedd Hospital, Bangor, North Wales (United Kingdom); Maddison, Adele [Nuffield Health, Shrewsbury Hospital (United Kingdom)

    2011-05-15

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  16. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  17. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  18. Radiographic markers - A reservoir for bacteria?

    International Nuclear Information System (INIS)

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  19. Gamma radiographic exposure time indicator

    International Nuclear Information System (INIS)

    In industrial radiography, with the proper selection of source and film, the radiographic quality depends very much on the exposure time, which in turn depends upon the source strength and the source to film distance. Conventional methods to arrive at correct exposure time involve time consuming calculations and in these methods the knowledge of the above mentioned parameters is imperative. An instrument to determine the required exposure time has been developed which indicates exposure times in about 30 secs. This covers two commonly used gamma radiography sources, viz., 192Ir and 60Co and six commonly used radiography films of different speeds. Knowledge of source strength and source to film distance is not required with the use of this instrument. With a knowledge of the total exposure required by the film to give the required sensitivity and by the measurement of radiation level at the film location, the correct exposure time is determined. The radiation level is measured by placing a GM counter behind the radiographic specimen at the film location. To match the responses of the film and the GM counter, the counter is incorporated in a suitably designed probe. In this instruments, an integrator to integrate the GM-pulses and a constant current integrator (timer) are started simultaneously. The voltage at the GM-pulse integrator is compared with a preselected voltage, (selected on the basis of film type, source, source strength and order of object thickness) by a comparator. The comparator is so adjusted that when the GM-pulse integrator voltage exceeds the preselected voltage, it switches its state and stops the integration of constant current. The constant current integrator output which is proportional to the time taken for the GM-pulse integrator to reach the preselected voltage, is read on a meter graduated in terms of exposure time. The instrument can measure exposure times from 5 minutes to 10 hours read in two ranges, the range-changing being automatic

  20. [The dental radiograph: pitfalls and surprises].

    Science.gov (United States)

    Bakx, S; Syriopoulos, K

    2015-05-01

    Guidelines allow retakes of dental radiographs of up to 10%. In the general practice the percentage of retakes is considerably higher. In intraoral radiography film positioning and faults in directing the collimator are the most common reasons for retakes. The use of film holders and correctly aiming the collimator decrease the risk of failure. In panoramic radiography the positioning of the patient in the x-ray machine and the palatoglossal air space are the main causes of failure of radiographs. A systematic approach, a thorough check of the radiation area for artefacts and the use of the available laser lines decrease the risk of a diagnostically unacceptable radiograph. PMID:26210220

  1. Radiographic evaluation of AIDS patients

    International Nuclear Information System (INIS)

    Morphological imaging, based on the use of various techniques including ultrasound, X-ray computed tomography (CT), and magnetic resonance imaging (MRI), plays an important role in the characterization, diagnosis and follow-up of patients with Human Immunodeficiency Virus (HIV) infection and Acquired Immunodeficiency Syndrome (AIDS). While the presence of thoracic infections, the most frequently observed illnesses in AIDS patients, can best be performed by using conventional chest films and CT, the assessment of cerebral involvement in AIDS patients - characterized by the presence of focal masses, demyelination, meningitis, and infarction - is best achieved using MRI. The work-up of patients with gastrointestinal symptoms should include the use of ultrasound for the evaluation of visceral involvement and lymphadenopathy, completed by CT to further characterize pathologic conditions in either the bowel or visceral organs. Ultrasound is the screening exam of choice in AIDS patients with suspected renal disease, but other methods may be necessary for the assessment of the complications due to pharmacological treatment. Musculoskeletal complications may require the combined use of all the above methods, since they may be caused by infections, tumors and rheumatologic illness. The use of the radiographic methods for the detection of the numerous forms of infections and malignancies in AIDS patients is described in detail for the various body districts

  2. Consultant radiographer leadership - A discussion

    International Nuclear Information System (INIS)

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills

  3. Preparation of barium hexaferrite powders using oxidized steel scales waste

    Science.gov (United States)

    Septiani, Ardita; Idayanti, Novrita; Kristiantoro, Tony

    2016-02-01

    Research on preparation of barium hexaferrite powders has been done using Hot Strip Mill scales as raw materials. Hot Strip Mill scales are oxidized steel scales waste from steel industrial process. The method used for preparing the barium hexaferrite powders was solid state reaction method. Oxidized steel scales were milled using ball mill for 10 hours, then screened through a 250 mesh sieve to obtain powders with maximum size of 63 µm. Powders were roasted at 600°C temperature for 4 hours to obtain hematite (Fe2O3) phase. Roasted powders were then mixed with barium carbonate, and were subsequently milled for 16 hours. After mixing, powders were calcined with an increasing rate of 10°C/min and maintained at 1100°C for 3 hours. Calcination process was performed to acquire barium hexaferrite phase. X-ray Diffraction (XRD) characterization in conjunction with RIR analysis showed that 85 wt. % of barium hexaferrite is formed. The magnetic properties of powders were characterized using Permagraph. It is found the value of remanent induction is 1.09 kG, coercivity of 2.043 kOe, and the maximum energy product of 0.25 MGOe.

  4. Barium Depletion in the NSTAR Discharge Cathode After 30,000 Hours of Operation

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2010-01-01

    Dispenser hollow cathodes rely on a consumable supply of barium released by impregnant materials in the pores of a tungsten matrix to maintain a low work function surface. Examinations of cathode inserts from long duration ion engine tests show deposits of tungsten at the downstream end that appear to block the flow of barium from the interior. In addition, a numerical model of barium transport in the insert plasma indicates that the barium partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant barium-producing reaction, and it was postulated previously that this would suppress barium loss in the upstream part of the insert. New measurements of the depth of barium depletion from a cathode insert operated for 30,352 hours reveal that barium loss is confined to a narrow region near the downstream end, confirming this hypothesis.

  5. Studies of hexacelsian and celsian barium aluminosilicates

    Science.gov (United States)

    Lee, Kuo-Tong

    1998-09-01

    The first part of this work (chapter 3) describes the reaction paths leading to the formation of BaAlsb2Sisb2Osb8 (BAS) from a mixture of gamma-BaCOsb3,\\ alpha-Alsb2Osb3, and amorphous SiOsb2 powders. Heat treatments conducted from 600 to 1200sp°C in air were used to transform the powder mixtures into hexacelsian BAS. The phase evolution to BAS was examined by x-ray diffraction. Several experiments were designed to microscopically reproduce the solid-solid interfaces expected during the synthesis of BAS and enabled the author to describe the different stages of the reaction. There exist two reaction paths in formation of BAS in this study: (1) formation of a series of barium silicates leading to BaO*2SiOsb2 (BSsb2) which then reacts with Alsb2Osb3 to form BAS and (2) formation of BaO*Alsb2Osb3 (BA) which then reacts with SiOsb2 to form BAS. The kinetics of the latter is slower than that of the former because the reaction between BaO*Alsb2Osb3 and SiOsb2 to form BAS includes a bond breaking process. The second part (chapter 4) of this research was undertaken to study the role of additives on the kinetics of the transformation of hexacelsian to celsian. Pre-synthesized hexacelsian powders doped with various additives were heated at temperatures ranging from 850 to 1400sp°C for 4 hrs. Semi-quantitative analysis of XRD was used to determine the extent of the hexacelsian-to-celsian transformation. This work was extended further to investigate the mechanisms involved in the transformation. Defect structures developed in the additive-containing celsian provide insights about the sites occupied by the cations added. Experimental results indicate that the doping of ˜0.99A cations in promoting the conversion of hexacelsian to celsian is by forming an interstitial solid solution in hexacelsian and ˜0.66A cations form a substitutional solid solution. In a kinetic study on the CaO- or MgO-enhanced transformation, values of rate constant, k, and Avlami constant, n, at

  6. Occupational doses in pediatric barium meal procedures

    International Nuclear Information System (INIS)

    Ionizing radiation has become an indispensable tool when it comes to diagnosis and therapy. However, its use should happen in a rational manner, taking into account the risks to which the staff is being exposed. Barium meal (BM), or upper gastrointestinal (GI) studies, using fluoroscopy, are widely used for gastroesophageal reflux disease diagnostic in children and professionals are required to stay inside the examination room to position and immobilize pediatric patients during the procedure. Therefore, it is very important that proffessionals strictly follow the technical standards of radiation protection. According to the ICRP and the NCRP recommendations, the annual limit equivalent doses for eyes, thyroid and hands are, espectively, 20 mSv, 150 mSv and 500 mSv. Based on those data, the aim of the current study is to estimate the annual equivalent dose for eyes, thyroid and hands of professionals who perform BM procedures in children. This was done using properly package LiF:Mg,Cu,P thermoluminescent dosimeters in 37 procedures; 2 pairs were positioned near each staff´s eye, 2 pairs on each professional´s neck (on and under the lead protector) and 2 pairs on both staff´s hands. The range of the estimative annual equivalent doses, for eyes, thyroid and hands, are, respectively: 14 – 36 mSv, 7 – 22 mSv and 14 – 58 mSv. Only the closest staff to the patient exceeded the annual equivalent doses in the eyes (around 80% higher than the limit set by ICRP). However, the results from this study, for hands and thyroid, compared to similar studies, show higher values. Therefore, the optimization implementation is necessary, so that the radiation levels can be reduced. (authors)

  7. Apparatus for unloading radiographic cassettes in daylight

    International Nuclear Information System (INIS)

    Mechanism, for automatically opening and unloading cassettes of exposed radiographic films, is contructed to unfasten them in inverted position and open them by hinging the container part of the cassette upwardly relative to the lid. (UK)

  8. Conventional radiology of osteoporosis and radiographic absorptiometry

    International Nuclear Information System (INIS)

    Radiographic findings suggestive of osteopenia and osteoporosis are frequently encountered in daily medical practice and can result from a wide spectrum of diseases ranging from highly prevalent causes such as postmenopausal and involutional osteoporosis to very rare endocrinologic and hereditary or acquired disorders. As bone mass is lost, changes in the trabecular and cortical bone structure occur. The changes that are visible on conventional radiographs may give specific information on the etiology of the underlying disease. Even though conventional radiography is indispensable in the differential diagnosis of osteopenia and osteoporosis, visual assessment of bone mass and its changes is subjective and strongly depends on the radiographic technique. With radiogrammetry and radiographic absorptiometry two methods exist that rely on conventional radiography and allow for a quantification of bone mass. (orig.)

  9. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.)

  10. Bacterial adherence and contamination during radiographic processing.

    Science.gov (United States)

    Bachman, C E; White, J M; Goodis, H E; Rosenquist, J W

    1990-11-01

    Oral fluids are potential contaminants of radiographic processors. This investigation measured bacterial contamination in a radiographic processing room during times of high and low clinical activity and processing effects on five types of microorganisms. Cultures in the clinical setting, during high and low activity, were taken by brain-heart infusion agar plates placed near automatic processors. Site samples were taken of entrance, developer, fixer, water, and exit surfaces. Measurements of processing effects were accomplished by intentional contamination of films run in series through an automatic processor. Site samples were again taken of the processor. In the clinical setting colony-forming units increased with activity. Radiographic processing after intentional contamination decreased colony-forming units on films, but they increased for all processing solutions. Bacteria on radiographic film survived processing. Although processing procedures significantly reduce the number of bacteria on films, the potential for contamination and cross-contamination remains. PMID:2122350

  11. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  12. Method for the extraction chromatographic separation of barium from other elements with dibenzo-18-crown-6

    International Nuclear Information System (INIS)

    A method has been developed for the extraction chromatographic separation of barium from 0.01 M picric acid solution with dibenzo-18-crown-6 coated on hydrophobic silica gel as the stationary phase. Various mineral acids can be used as stripping agents. Barium was separated from other elements by selective extraction and the separation of barium from alkali and alkaline earth metals, uranium, thorium and lead was achieved. The method was applied to the determination of barium in real samples. (author)

  13. Recycle silver metal from radiographic film waste

    International Nuclear Information System (INIS)

    The laboratory techniques described herein refer to the possible recovery of silver metal from used photographic films. Recovery of silver from x-ray film involves two steps: the separation of metallic component from the processed radiographic films (organic component), and the recovery of silver. The present paper reports a method for separating the inorganic component by treating the processed radiographic film with heated sodium hydroxide solution. (Author)

  14. The 'ABC' of examining foot radiographs.

    OpenAIRE

    Pearse, Eyiyemi O.; Klass, Benjamin; Bendall, Stephen P.

    2005-01-01

    INTRODUCTION: We report a simple systematic method of assessing foot radiographs that improves diagnostic accuracy and can reduce the incidence of inappropriate management of serious forefoot and midfoot injuries, particularly the Lisfranc-type injury. STUDY GROUP AND METHODS: Five recently appointed senior house officers (SHOs), with no casualty or Orthopaedic experience prior to their appointment, were shown a set of 10 foot radiographs and told the history and examination findings recorded...

  15. The Radiographic Approach to Child Abuse

    OpenAIRE

    Dwek, Jerry R.

    2010-01-01

    Background Osseous injuries are a major facet of child abuse and in most patients radiographic imaging plays a major role in diagnosis. While some injuries are typically produced as a result of excessive and inappropriate force other injuries are nonspecific in terms of their causation, but become suspicious when the history provided by the caretakers is inconsistent with the type of injury produced. Questions/purposes I detail the radiographic imaging of the more characteristic of the highly...

  16. Electron microscopy of barium bismuth titanate multilayer ceramics

    International Nuclear Information System (INIS)

    For a number of years bismuth containing compounds have been used with pre-calcined barium titanate to reduce the sintering temperature of the capacitor formulations. As reported earlier the backscattered electron (BSE) SEM micrographs of the bismuth containing barium titanate ceramic reveal that the grains having an average size of 1.2μm consist of a two phase structure consisting of relatively pure barium titanate grain cores surrounded by bismuth rich grain shells. The TEM and STEM studies along with the EDS analyses show that the bismuth concentration increases sharply as one steps towards the grain boundary with a maximum bismuth content at the grain boundary. It is the purpose of this work to investigate the distribution of bismuth in these formulations including the bismuth content, if any, at the ceramic metal interface as affected by the sintering temperature. The subsequent effect on the electrical resistivity of these ceramics in the multilayer configuration is reported

  17. Economically dissolving barium sulfate scale with a chelating agent

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, E.A.; Scheuerman, R.E.

    1977-06-21

    A composition is described for dissolving a barium sulfate scale from a subterranean or other relatively remote location into which fluid can be flowed. Fluid is flow-flowed into the remote location so that a stream of fluid contacts and flows along the surface of the scale. The composition and flow rate of the fluid are adjusted so that (1) the scale is contacted by a stream of aqueous solution in which each portion contains enough dissolved aminopolyacetic acid salt chelating agent to dissolve barium sulfate, and (2) substantially all upstream portions of the scale are contacted by a succession of portions of the aqueous liquid which are substantially unsaturated with respect to dissolved barium-chelant complex. (5 claims)

  18. Barium titanate thick films prepared by screen printing technique

    Directory of Open Access Journals (Sweden)

    Mirjana M. Vijatović

    2010-06-01

    Full Text Available The barium titanate (BaTiO3 thick films were prepared by screen printing technique using powders obtained by soft chemical route, modified Pechini process. Three different barium titanate powders were prepared: i pure, ii doped with lanthanum and iii doped with antimony. Pastes for screen printing were prepared using previously obtained powders. The thick films were deposited onto Al2O3 substrates and fired at 850°C together with electrode material (silver/palladium in the moving belt furnace in the air atmosphere. Measurements of thickness and roughness of barium titanate thick films were performed. The electrical properties of thick films such as dielectric constant, dielectric losses, Curie temperature, hysteresis loop were reported. The influence of different factors on electrical properties values was analyzed.

  19. MRI of radiographically occult ischial apophyseal avulsions

    International Nuclear Information System (INIS)

    Acute avulsions of unossified ischial apophyses in children may go undetected on radiography. Therapy includes rest and rehabilitation; however, substantial displacement may require surgery. Our purpose is to illustrate the utility of MRI in the detection of these radiographically occult injuries in skeletally immature children. This retrospective study of more than 5 years included children with ischial avulsions who were evaluated with both radiography and MRI within 3 weeks of acute injury. Initially, radiographs were reviewed to identify those children with unossified ischial apophyses. Subsequently, their MRI examinations were assessed for physeal disruption, bone/soft tissue edema, periosteal/perichondrial elevation and disruption. Initial and follow-up radiographs (if available) were reviewed. Patient age, symptoms and offending activity were determined from clinical records. Five children met inclusion criteria. All initial radiographs were normal. MRI showed: edema (n = 5), periosteal elevation (n = 4), periosteal/perichondrial disruption (n = 4), >5.5 mm displacement (n = 0). Follow-up radiographs in two children (2 and 2.5 months from MRI) showed osseous ischial irregularity. The apophyses remained unossified. Acute unossified ischial apophyseal avulsions in children may be radiographically undetected. In the setting of correlative clinical symptoms, MRI can be used to identify these injuries and to help direct appropriate therapy. (orig.)

  20. The 'ABC' of examining foot radiographs.

    Science.gov (United States)

    Pearse, Eyiyemi O.; Klass, Benjamin; Bendall, Stephen P.

    2005-01-01

    INTRODUCTION: We report a simple systematic method of assessing foot radiographs that improves diagnostic accuracy and can reduce the incidence of inappropriate management of serious forefoot and midfoot injuries, particularly the Lisfranc-type injury. STUDY GROUP AND METHODS: Five recently appointed senior house officers (SHOs), with no casualty or Orthopaedic experience prior to their appointment, were shown a set of 10 foot radiographs and told the history and examination findings recorded in the casualty notes of each patient within 6 weeks of taking up their posts. They were informed that the radiographs might or might not demonstrate an abnormality. They were asked to make a diagnosis and decide on a management plan. The test was repeated after they were taught the 'ABC' method of evaluating foot radiographs. RESULTS: Diagnostic accuracy improved after SHOs were taught a systematic method of assessing foot radiographs. The proportion of correct diagnoses increased from 0.64 to 0.78 and the probability of recognising Lisfranc injuries increased from 0 to 0.6. CONCLUSIONS: The use of this simple method of assessing foot radiographs can reduce the incidence of inappropriate management of serious foot injuries by casualty SHOs, in particular the Lisfranc type injury. PMID:16263015

  1. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  2. MRI of radiographically occult ischial apophyseal avulsions

    Energy Technology Data Exchange (ETDEWEB)

    Meyers, Arthur B. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Children' s Hospital of Wisconsin, Milwaukee, WI (United States); Laor, Tal; Zbojniewicz, Andrew M.; Anton, Christopher G. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States)

    2012-11-15

    Acute avulsions of unossified ischial apophyses in children may go undetected on radiography. Therapy includes rest and rehabilitation; however, substantial displacement may require surgery. Our purpose is to illustrate the utility of MRI in the detection of these radiographically occult injuries in skeletally immature children. This retrospective study of more than 5 years included children with ischial avulsions who were evaluated with both radiography and MRI within 3 weeks of acute injury. Initially, radiographs were reviewed to identify those children with unossified ischial apophyses. Subsequently, their MRI examinations were assessed for physeal disruption, bone/soft tissue edema, periosteal/perichondrial elevation and disruption. Initial and follow-up radiographs (if available) were reviewed. Patient age, symptoms and offending activity were determined from clinical records. Five children met inclusion criteria. All initial radiographs were normal. MRI showed: edema (n = 5), periosteal elevation (n = 4), periosteal/perichondrial disruption (n = 4), >5.5 mm displacement (n = 0). Follow-up radiographs in two children (2 and 2.5 months from MRI) showed osseous ischial irregularity. The apophyses remained unossified. Acute unossified ischial apophyseal avulsions in children may be radiographically undetected. In the setting of correlative clinical symptoms, MRI can be used to identify these injuries and to help direct appropriate therapy. (orig.)

  3. [Indications for and frequency of intraoral radiographs].

    Science.gov (United States)

    Poorterman, J H G

    2015-05-01

    Radiographs are essential in dental practice today. Due to the exposure of patients to X-rays every radiograph has to be justified. The advantages and disadvantages of risks and diagnostic rewards have to be weighed against one another whenever X-ray imaging is considered. An important factor in this respect is the usefulness (in terms of sensitivity and specificity) of a radiograph and along with that, the monitoring of the quality of the entire process, from positioning the photo up to and including the development or scanning of it. Both for children and adults the indication for taking radiographs must be made on an individual basis. The most important considerations are: caries experience, oral hygiene and nutritional habits and exposure to fluorides. Based on these factors an individual risk assessment can be made and the possible benefit of bitewing radiographs for the dental treatment can be determined. European guidelines give advice on the indications and frequency of radiographs in, among other fields, periodontology, endodontology and implantology. PMID:26210219

  4. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  5. Functional and Anatomic Esophagogastic Junction Outflow Obstruction: Manometry, Timed Barium Esophagram Findings, and Treatment Outcomes.

    Science.gov (United States)

    Clayton, Steven B; Patel, Rupal; Richter, Joel E

    2016-06-01

    Little is known about the clinical features, radiology and manometry findings, and treatment outcomes of patients with functional and mechanical esophagogastic junction outflow obstruction (EGJOO). Between November 2011 and February 2015, a total of 1443 high-resolution manometries were reviewed and 49 patients (3.4%) met the manometric criteria for EGJOO. Then, we performed a retrospective chart review, collecting data from manometric studies, timed barium esophagram findings (TBEs), endoscopic reports, and clinical records. Twenty-seven patients had functional EGJOO and 22 patients had an anatomic esophageal obstruction. Common causes of anatomic EGJOO included strictures (36% of patients) and hiatal hernias (31% of patients). There were no differences between groups in manometric or radiographic metrics. Each group had increased basal lower esophageal sphincter and intrabolus pressures, compared with individuals without EGJOO, and most patients had abnormal findings on TBE analysis. Two patients with functional EGJOO progressed to type 3 achalasia. We conclude that patients diagnosed with EGJOO based on manometry findings can have anatomic obstruction or functional EGJOO; high-resolution manometry and TBE do not distinguish between disease causes. PMID:26792374

  6. Reaction sintering of a zirconia-containing barium feldspar ceramic

    International Nuclear Information System (INIS)

    Zircon (ZrSiO4) is a natural mineral resource known to react with certain oxides to produce a dispersion of zirconia particles within ceramic or glass-ceramic matrices. Barium aluminosilicates, particularly the celsian polymorphs of BaO- Al2O3 2SiO2 display oxidation resistance and refractory characteristics commensurate with the properties required of high temperature materials. Such properties, coupled with the high melting point of ZrO2 (2680 deg C), suggest that barium aluminosilicates and zirconia are an ideal combination from which to fabricate high temperature materials. A recent study has indicated that a barium aluminosilicate containing up to 40mol% ZrO2 can be prepared via a sol-gel process. However, the desire to utilise a natural resource in the form of zircon in the present work has led to the choice of reaction sintering as an alternative processing route. The current work was undertaken to investigate the possibility of forming a zirconia-containing barium feldspar composite material using the reaction sintering of zircon and assuming the following stoichiometric reaction: 2ZrSiO4 + BaCO3 + Al2O3 → 2ZrO2 + BaO-Al2O3-2SiO2 + CO2 ↑. The reaction sintering of zircon with alumina and barium carbonate produces a composite material comprising distributed ZrO2 in a continous barium feldspar matrix. Yttria added during processing allows a significant fraction of the ZrO2 to be retained as tetragonal phase to room temperature and thus the potential for a measure of transformation toughening

  7. Reaction sintering of a zirconia-containing barium feldspar ceramic

    Energy Technology Data Exchange (ETDEWEB)

    Nordmann, A.; Cheng, Y-B.; Muddle, B. C. [Monash Univ., Clayton, VIC (Australia). Dept. of Materials Engineering

    1996-12-31

    Zircon (ZrSiO{sub 4}) is a natural mineral resource known to react with certain oxides to produce a dispersion of zirconia particles within ceramic or glass-ceramic matrices. Barium aluminosilicates, particularly the celsian polymorphs of BaO- Al{sub 2}O{sub 3} 2SiO{sub 2} display oxidation resistance and refractory characteristics commensurate with the properties required of high temperature materials. Such properties, coupled with the high melting point of ZrO{sub 2} (2680 deg C), suggest that barium aluminosilicates and zirconia are an ideal combination from which to fabricate high temperature materials. A recent study has indicated that a barium aluminosilicate containing up to 40mol% ZrO{sub 2} can be prepared via a sol-gel process. However, the desire to utilise a natural resource in the form of zircon in the present work has led to the choice of reaction sintering as an alternative processing route. The current work was undertaken to investigate the possibility of forming a zirconia-containing barium feldspar composite material using the reaction sintering of zircon and assuming the following stoichiometric reaction: 2ZrSiO{sub 4} + BaCO{sub 3} + Al{sub 2}O{sub 3} {yields} 2ZrO{sub 2} + BaO-Al{sub 2}O{sub 3}-2SiO{sub 2} + CO{sub 2} {up_arrow}. The reaction sintering of zircon with alumina and barium carbonate produces a composite material comprising distributed ZrO{sub 2} in a continous barium feldspar matrix. Yttria added during processing allows a significant fraction of the ZrO{sub 2} to be retained as tetragonal phase to room temperature and thus the potential for a measure of transformation toughening. 14 refs., 2 tabs., 6 figs.

  8. Compact pulse forming line using barium titanate ceramic material

    Science.gov (United States)

    Kumar Sharma, Surender; Deb, P.; Shukla, R.; Prabaharan, T.; Shyam, A.

    2011-11-01

    Ceramic material has very high relative permittivity, so compact pulse forming line can be made using these materials. Barium titanate (BaTiO3) has a relative permittivity of 1200 so it is used for making compact pulse forming line (PFL). Barium titanate also has piezoelectric effects so it cracks during high voltages discharges due to stresses developed in it. Barium titanate is mixed with rubber which absorbs the piezoelectric stresses when the PFL is charged and regain its original shape after the discharge. A composite mixture of barium titanate with the neoprene rubber is prepared. The relative permittivity of the composite mixture is measured to be 85. A coaxial pulse forming line of inner diameter 120 mm, outer diameter 240 mm, and length 350 mm is made and the composite mixture of barium titanate and neoprene rubber is filled between the inner and outer cylinders. The PFL is charged up to 120 kV and discharged into 5 Ω load. The voltage pulse of 70 kV, 21 ns is measured across the load. The conventional PFL is made up of oil or plastics dielectrics with the relative permittivity of 2-10 [D. R. Linde, CRC Handbook of Chemistry and Physics, 90th ed. (CRC, 2009); Xia et al., Rev. Sci. Instrum. 79, 086113 (2008); Yang et al., Rev. Sci. Instrum. 81, 43303 (2010)], which increases the length of PFL. We have reported the compactness in length achieved due to increase in relative permittivity of composite mixture by adding barium titanate in neoprene rubber.

  9. Compact pulse forming line using barium titanate ceramic material.

    Science.gov (United States)

    Kumar Sharma, Surender; Deb, P; Shukla, R; Prabaharan, T; Shyam, A

    2011-11-01

    Ceramic material has very high relative permittivity, so compact pulse forming line can be made using these materials. Barium titanate (BaTiO(3)) has a relative permittivity of 1200 so it is used for making compact pulse forming line (PFL). Barium titanate also has piezoelectric effects so it cracks during high voltages discharges due to stresses developed in it. Barium titanate is mixed with rubber which absorbs the piezoelectric stresses when the PFL is charged and regain its original shape after the discharge. A composite mixture of barium titanate with the neoprene rubber is prepared. The relative permittivity of the composite mixture is measured to be 85. A coaxial pulse forming line of inner diameter 120 mm, outer diameter 240 mm, and length 350 mm is made and the composite mixture of barium titanate and neoprene rubber is filled between the inner and outer cylinders. The PFL is charged up to 120 kV and discharged into 5 Ω load. The voltage pulse of 70 kV, 21 ns is measured across the load. The conventional PFL is made up of oil or plastics dielectrics with the relative permittivity of 2-10 [D. R. Linde, CRC Handbook of Chemistry and Physics, 90th ed. (CRC, 2009); Xia et al., Rev. Sci. Instrum. 79, 086113 (2008); Yang et al., Rev. Sci. Instrum. 81, 43303 (2010)], which increases the length of PFL. We have reported the compactness in length achieved due to increase in relative permittivity of composite mixture by adding barium titanate in neoprene rubber. PMID:22129008

  10. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Barium azide-50 percent or more water wet. 173.182 Section 173.182 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or...

  11. 21 CFR 201.304 - Tannic acid and barium enema preparations.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Tannic acid and barium enema preparations. 201.304... Tannic acid and barium enema preparations. (a) It has become a widespread practice for tannic acid to be added to barium enemas to improve X-ray pictures. Tannic acid is capable of causing diminished...

  12. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium manganese oxide (BaMnO3). 721... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN...

  13. The adhesiometer: a simple device to measure adherence of barium sulfate to intestinal mucosa.

    Science.gov (United States)

    Salomonowitz, E; Frick, M P; Cragg, A H; Lund, G

    1984-04-01

    A simple, inexpensive device assessing barium sulfate adherence to alimentary tract mucosa was tested in an animal study using pigs and dogs. Interaction of gastric, intestinal, and colonic mucosal lining with three different barium preparations was studied. In both pigs and dogs, barium adherence to gastric mucosa was significantly stronger when compared with colonic mucosa. PMID:6608230

  14. Esophageal intramural pseudodiverticulosis characterized by barium esophagography: a case report

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-05-21

    Abstract Introduction Esophageal intramural pseudodiverticulosis is a rare condition characterized by the dilatation of the submucosal glands. Case presentation We present a case of esophageal intramural pseudodiverticulosis in a 72-year-old Caucasian man who presented with dysphagia and with a background history of alcohol abuse. An upper gastrointestinal endoscopy of our patient showed an esophageal stricture with abnormal mucosal appearances, but no malignant cells were seen at biopsy. Appearances on a barium esophagram were pathognomonic for esophageal intramural pseudodiverticulosis. Conclusion We demonstrate the enduring usefulness of barium esophagography in the characterization of abnormal mucosal appearances at endoscopy.

  15. Kinetics of thermal decomposition of barium zirconyl oxalate

    International Nuclear Information System (INIS)

    Kinetics of the thermal decomposition of anhydrous barium zirconyl oxalate and a carbonate intermediate have been studied. Decomposition of the anhydrous oxalate, though it could be explained based on a contracting-cube model, is quite complex. Kinetics of decomposition of the intermediate carbonate Ba2Zr2O5CO3 is greatly influenced by thermal effects during its formation. (α-t) curves are sigmoidal and obey a power law equation followed by first order decay. Presence of carbon in the vacuum-prepared carbonate has a strong deactivating effect. Decomposition of the carbonate is accompanied by growth in particle size of the product barium zirconate. (Author)

  16. Photoionization and Photoelectric Loading of Barium Ion Traps

    CERN Document Server

    Steele, A V; Churchill, L R; Griffin, P F

    2007-01-01

    Simple and effective techniques for loading barium ions into linear Paul traps are demonstrated. Two-step photoionization of neutral barium is achieved using a weak intercombination line (6s2 1S0 6s6p 3P1, 791 nm) followed by excitation above the ionization threshold using a nitrogen gas laser (337 nm). Isotopic selectivity is achieved by using a near Doppler-free geometry for excitation of the triplet 6s6p 3P1 state. Additionally, we report a particularly simple and efficient trap loading technique that employs an in-expensive UV epoxy curing lamp to generate photoelectrons.

  17. Photoionization and Photoelectric Loading of Barium Ion Traps

    OpenAIRE

    Steele, A. V.; Churchill, L. R.; Griffin, P. F.; Chapman, M. S.

    2007-01-01

    Simple and effective techniques for loading barium ions into linear Paul traps are demonstrated. Two-step photoionization of neutral barium is achieved using a weak intercombination line (6s2 1S0 6s6p 3P1, 791 nm) followed by excitation above the ionization threshold using a nitrogen gas laser (337 nm). Isotopic selectivity is achieved by using a near Doppler-free geometry for excitation of the triplet 6s6p 3P1 state. Additionally, we report a particularly simple and efficient trap loading t...

  18. Equations of state for barium in high-pressure phases

    International Nuclear Information System (INIS)

    The universal equation of state with an arbitrary reference point presented by the author (Fang Zheng-Hua 1998 Phys. Rev. B 50 16 238) is applied successfully to the analysis of the experimental compression data of barium in different structural phases (I, II, and V). The comparison given in this paper shows that this equation suits for the isothermal compression behaviour of barium in the high-pressure phases (II and V) better than the Birch-Murnaghan equation. The applicability of equations of state for solids in high-pressure phases is also discussed. (author)

  19. Chemical abundance analysis of 19 barium stars

    Science.gov (United States)

    Yang, Guo-Chao; Liang, Yan-Chun; Spite, Monique; Chen, Yu-Qin; Zhao, Gang; Zhang, Bo; Liu, Guo-Qing; Liu, Yu-Juan; Liu, Nian; Deng, Li-Cai; Spite, Francois; Hill, Vanessa; Zhang, Cai-Xia

    2016-01-01

    We aim at deriving accurate atmospheric parameters and chemical abundances of 19 barium (Ba) stars, including both strong and mild Ba stars, based on the high signal-to-noise ratio and high resolution Echelle spectra obtained from the 2.16 m telescope at Xinglong station of National Astronomical Observatories, Chinese Academy of Sciences. The chemical abundances of the sample stars were obtained from an LTE, plane-parallel and line-blanketed atmospheric model by inputting the atmospheric parameters (effective temperatures Teff, surface gravities log g, metallicity [Fe/H] and microturbulence velocity ξt) and equivalent widths of stellar absorption lines. These samples of Ba stars are giants as indicated by atmospheric parameters, metallicities and kinematic analysis about UVW velocity. Chemical abundances of 17 elements were obtained for these Ba stars. Their Na, Al, α- and iron-peak elements (O, Na, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn, Ni) are similar to the solar abundances. Our samples of Ba stars show obvious overabundances of neutron-capture (n-capture) process elements relative to the Sun. Their median abundances of [Ba/Fe], [La/Fe] and [Eu/Fe] are 0.54, 0.65 and 0.40, respectively. The Y I and Zr I abundances are lower than Ba, La and Eu, but higher than the α- and iron-peak elements for the strong Ba stars and similar to the iron-peak elements for the mild stars. There exists a positive correlation between Ba intensity and [Ba/Fe]. For the n-capture elements (Y, Zr, Ba, La), there is an anti-correlation between their [X/Fe] and [Fe/H]. We identify nine of our sample stars as strong Ba stars with [Ba/Fe] >0.6 where seven of them have Ba intensity Ba=2-5, one has Ba=1.5 and another one has Ba=1.0. The remaining ten stars are classified as mild Ba stars with 0.17<[Ba/Fe] <0.54.

  20. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  1. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  2. Predicting lower third molar eruption on panoramic radiographs after cephalometric comparison of profile and panoramic radiographs

    DEFF Research Database (Denmark)

    Begtrup, Anders; Grønastøð, Halldis Á; Christensen, Ib Jarle; Kjær, Inger

    2012-01-01

    find a simple and reliable method for predicting the eruption of the mandibular third molar by measurements on panoramic radiographs. The material consisted of profile and panoramic radiographs, taken before orthodontic treatment, of 30 males and 23 females (median age 22, range 18-48 years), with no...

  3. Radiographic-anatomical aspects and gastrointestinal transit time in the spectacled caiman Caiman crocodilus crocodilus (Linnaeus, 1758 (Crocodylia, Alligatoridae

    Directory of Open Access Journals (Sweden)

    Heloisa Castro Pereira

    2014-09-01

    Full Text Available In Brazil, there is increasing interest in the establishment of captive breeding programs for caiman. However, there is a paucity of in-depth studies on the proper care of these reptiles in captivity, particularly regarding optimal food type and frequency of feeding. The purpose of this study was to determine radiographic-anatomical aspects of, and gastrointestinal transit time of Caiman crocodilus crocodilus using contrast radiography. Ten caiman were used in the study, five males and five females, the animals were physically restrained for administration of a radiographic contrast medium, consisting of 10 ml/kg barium sulfate and mineral oil suspension (70%: 30% respectively, via the orogastric tube. Following contrast medium administration, radiographs were taken via dorsoventral projection first at five minutes, then at 6, 24, 30, 48, 54, 72, 80, 96, 104, 120, 130, 144 and 150 hours. This technique allows visualization of contrast medium passage through the GI tract, which enabled determination of gastrointestinal transit time in the spectacled caiman. The average time for contrast medium passage through the digestive tract of this species was 117 ± 29.6 h for females and 86.4 ± 21.5 h for males.

  4. BARIUM AND RADIUM REMOVAL FROM GROUNDWATER BY ION EXCHANGE

    Science.gov (United States)

    The primary objective of this study was to determine the applicability of weak acid exchange resin in the hydrogen form for removal of hardness, barium and radium from groundwater. Weak acid resin in the hydrogen form eliminates the addition of sodium to drinking water. The capac...

  5. PROPOSED ORAL REFERENCE DOSE (RFD) FOR BARIUM AND COMPOUNDS

    Science.gov (United States)

    The Integrated Risk Information System (IRIS) is a database of EPA's consensus opinion of the human health effects that may result from exposure to various substances found in the environment. A Toxicological Review and IRIS Summary were prepared for barium and compounds in 1998 ...

  6. Barium titanate inverted opals-synthesis, characterization, and optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Soten, I.; Miguez, H.; Yang, S.M.; Petrov, S.; Coombs, N.; Tetreault, N.; Ozin, G.A. [Toronto Univ., ON (Canada). Dept. of Chemistry; Matsuura, N.; Ruda, H.E. [Toronto Univ., ON (Canada). Dept. of Metallurgy and Materials Science

    2002-01-01

    The engineering of cubic or tetragonal polymorphs of nanocrystalline barium titanate inverted opals has been achieved by thermally induced transformations. Optical characterization demonstrated photonic crystal behavior of the opals. The tuning of the ferroelectric-paraelectric transition around the Curie temperature is shown in this paper. (orig.)

  7. Nanocrystals formation on Ho3+ doped strontium barium niobate glass

    International Nuclear Information System (INIS)

    The study of two different methods to obtain strontium barium niobate nanocrystals immersed in a glass matrix has been carried out. Ho2O3-doped SrO-BaO-Nb2O5-B2O3 glasses were fabricated using the melt quenching method. Glass ceramic samples were obtained from the precursor glass by thermal treatment in a furnace and by laser irradiation. These glass ceramic samples are formed by a glassy phase and a crystalline phase of strontium barium niobate nanocrystals. This structure was confirmed by X-ray diffraction and Atomic Force Microscope images. The incorporation of Ho3+ ions in the strontium barium niobate nanocrystals were corroborated by optical measurements, which produced an increment in the luminescence intensity compared to the precursor glass. - Research Highlights: →Ho doped strontium barium niobate nanocrystals have been obtained. →XRD, AFM and optical measurements corroborate the formation of SBN. →A laser irradiation technique has been carried out successfully.

  8. Removal of barium and radium from groundwater. Environmental research brief

    International Nuclear Information System (INIS)

    A research project was undertaken to investigate processes for removing barium and radium from drinking water. Special emphasis was placed on ion exchange processes that can be used without adding large concentrations of sodium to the water. The wastes from radium and barium removal processes were also characterized, and processes suitable for treatment of ion-exchange brines were evaluated. The report discusses two ion-exchange processes that can be used for barium and radium removal accompanied by either partial or no hardness removal. The calcium-form, strong-acid ion-exchange resin can be used for barium and radium removal without significant change in hardness or the concentration of other salts. This resin can be regenerated with CaC12 brine. The radium-selective complexer (RSC) will remove radium without altering hardness or other salt concentration. The capacity of this resin for waters with low total dissolved solids (TDS) (<1000 to 2000 mg/L TDS) is in excess of 30,000 pCi/dry g; however, if the TDS is increased to about 40,000 mg/L, the capacity drops to 200 to 300 pCi/dry g. Thus using this resin to remove radium from spent brine does not appear feasible

  9. CNO and F abundances in the barium star HD 123396

    CERN Document Server

    Alves-Brito, Alan; Yong, David; Meléndez, Jorge; Vásquez, Sergio

    2011-01-01

    [Abridged] Barium stars are moderately rare chemically peculiar objects which are believed to be the result of the pollution of an otherwise normal star by material from an evolved companion on the asymptotic giant branch (AGB). We aim to derive carbon, nitrogen, oxygen, and fluorine abundances for the first time from infrared spectra of the barium red giant star HD 123396 to quantitatively test AGB nucleosynthesis models for producing barium stars via mass accretion. High-resolution and high S/N infrared spectra were obtained using the Phoenix spectrograph mounted at the Gemini South telescope. The abundances were obtained through spectrum synthesis of individual atomic and molecular lines, using the MOOG stellar line analysis program together with Kurucz's stellar atmosphere models. The analysis was classical, using 1D stellar models and spectral synthesis under the assumption of local thermodynamic equilibrium. We confirm that HD 123396 is a metal-deficient barium star ([Fe/H] = -1.05), with A(C) = 7.88, A...

  10. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  11. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  12. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  13. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  14. Review on radiographic inspection in 1982

    International Nuclear Information System (INIS)

    This is a report of the activities in the radiographic inspection department of Japanese Society for Non-destructive Inspection. The contents of activities are described about the following 15 items: standards, minimum discernible contrast and image distribution, contrast meter and penetrameter sensitivity, testing conditions, detection limit and simulation, photographing method for tube welding and corner welding, relationship between irradiation direction and flaw detectability, abnormal images, RI sources, X-ray equipment and observing device, sensitive materials, detectors, image processing and X-ray TV and automation, neutron radiography, other application and new techniques, and safety. Concerning the ''standards'', discussion was performed on revising JIS Z 3105 ''Methods of Radiographic Test and Classification of Radiographs for Aluminum Welds''. In ''Abnormal images'', the verification by the author that the abnormal shadows generated in the radiographic images of austenitic steel welded parts are the diffraction phenomenon to satisfy the Bragg's conditions is reported. In ''RI sources'', Yb-169 was found to be a good radiation source for relatively thin steel plates. In ''neutron radiography'', it was confirmed that the neutron radiography using a cyclotron as a neutron source can be used practically by its fundamental tests. ''Application and new techniques'' include a trial to utilize scattered radiation as a source, the testing method of γ shield for spent fuel transportation, the improvement of X-ray radiographic test for titanium thin plates and thin wall tubes, and others. (Wakatsuki, Y.)

  15. Ultra-low temperature processing of barium tellurate dielectrics

    Science.gov (United States)

    Kwon, Do-Kyun

    Ceramics, metals and polymers have unique electrical properties that are combined for electronic devices and systems. It necessitates lower processing temperatures for ceramics to be compatible with metal and polymer systems. In this thesis, the synthesis, crystal structure, and dielectric properties of barium tellurate are studied for temperatures between 500 and 900°C. Barium tellurate dielectric ceramics (BaTe4O9, BaTe 2O5, BaTe2O6, BaTeO3, BaTeO 4, and Ba2TeO5) are extensively investigated as new LTCC (Low-Temperature Cofired Ceramics) dielectric systems integrated with low resistivity metal electrodes such as silver and aluminum for microwave application. Studies on the phase formation and crystal structure through thermal analyses (Differential Scanning Calorimetry and Thermogravimetric Analysis, DSC-TGA) and X-ray diffraction phase analysis attest that barium tellurates are formed in the temperature range of 500 ˜ 900°C, through the sequential phase formations from Te-rich to Ba-rich phases. The oxygen coordination of the tellurium ion progresses from TeO4 to TeO6 via TeO 3+1 and TeO3 with increasing barium content as confirmed by structural analysis using infrared spectroscopy. High density barium tellurate ceramics are achieved at temperatures as low as 550°C, which provides the potential to be co-fired with low-melting aluminum metal electrodes in LTCC processing. Dielectric permittivity, loss, and temperature stability of barium tellurate dielectric ceramics were measured from 100 Hz to 13 GHz. Barium tellurate ceramics exhibit excellent microwave dielectric properties with intermediate dielectric permittivities and high quality factors (Q). The dielectric properties at microwave frequencies are epsilonr = 17.5, Qxf = 54700 GHz, TCf = -90 ppm/°C for BaTe4O9, epsilonr = 21, Qxf = 50300 GHz, TCf = -51 ppm/°C for BaTe2O6, epsilonr = 10, Qxf = 34000 GHz, TCf = -54 ppm/°C for BaTeO3, and epsilonr = 17, Qx f = 49600 GHz, TCf = -124 ppm/°C for Ba 2TeO5

  16. Comparison of upper gastrointestinal radiographic findings to histopathologic observations: a retrospective study of 41 dogs and cats with suspected small bowel infiltrative disease (1985 to 1990)

    International Nuclear Information System (INIS)

    It was the intent of this study to define which, if any, radiographic observations corresponded with specific causes of diffuse infiltrative small bowel disease and if radiographic findings could differentiate inflammatory disease from neoplastic disease and either of them from normal. Bowel spasticity, luminal narrowing, and thumb printing tend to indicate the presence of tumor more often than inflammatory disease. Increased bowel gas in cats and barium adhesion in dogs and cats suggest that a component of enteritis is present. Decreased bowel gas in dogs is more often associated with obstructive disease, but is not helpful in differentiating diffuse inflammatory disease from diffuse neoplastic disease. While several observations that can foster differentiation of neoplastic from inflammatory disease were found, this study also indicated that the UGI lacks a high degree of predictive value other than to indicate the presence of infiltrative small bowel disease

  17. Clinical and radiographic maxillofacial features of pycnodysostosis.

    Science.gov (United States)

    Alves, Nilton; Cantín, Mario

    2014-01-01

    The aim of this study was to review of the literature to determine the radiographic and clinical maxillofacial features of pycnodysostosis emphasizing the main aspects of interest to the dentist in order to make them fit for the proper treatment of this population. It is important to make the diagnosis as early as possible in order to plan the treatment more suitable to provide a better life's quality to the patients. The most frequent clinical maxillofacial features were: grooved palate, midfacial hypoplasia, mandibular hypoplasia and enamel hypoplasia. The most common radiographic maxillofacial features were: obtuse mandibular angle, frontal/parietal/occiptal bossing, open fontanels and sutures, multiple impacted teeth. The earlier diagnostic of pycnodysostosis has a fundamental role in general health of the patients. We consider that is very important that the dentist know recognize the radiographic and clinical maxillofacial features of pycnodysostosis, which allows correct treatment planning avoiding risks and ensuring better life's quality to the patients. PMID:24753741

  18. Magnetic cassette for radiographic film material

    International Nuclear Information System (INIS)

    A radiographic film cassette having a plurality of magnet components integral with the cassette holder for adhering the cassette to ferrous material in X-raying for defects in welds or fissures in shipyards, pipe lines, or the like. What is provided is a substantially flexible cassette envelope comprising first and second layers of radiographic intensifying screens with a sheet of radiographic film positioned therebetween. The cassette would be a cassette envelope constructed of waterproof fabric or other suitable material providing a light-free environment, and having the ability to flex around the curvature of the surface of a pipe or the like to be x-rayed. There is further provided a plurality of magnet components, preferably situated in each corner of the cassette envelope and flexibly attached thereto for overall adherence of the envelope to the surface of the pipe or the like to be x-rayed during the process

  19. Computerized analysis of osteoporosis on bone radiographs

    International Nuclear Information System (INIS)

    Osteoporosis is a common disease of bone, with many patients remaining asymptomatic until bone demineralization is noted on a radiograph obtained for unrelated reasons. The authors of this paper are developing a computerized scheme to aid radiologists in detection and staging of osteoporosis in bone radiographs of hands, hips, and spine. Bone radiographs of healthy patients and those with osteoporosis were digitized with a laser scanner. Texture analysis techniques, previously developed for analysis of interstitial lung disease, were applied to selected regions of interest in images of the hands, hips, and spine. The magnitude and spatial frequency content of the texture was given by the RMS variation and first moment of the power spectrum, respectively

  20. Radiographic findings in tuberculosis of the calvarium

    Energy Technology Data Exchange (ETDEWEB)

    Patankar, T.; Varma, R.; Krishnan, A.; Prasad, S. [Dept. of Radiology, King Edward Memorial Hospital, Parel, Bombay (India); Desai, K. [Dept. of Neurosurgery, King Edward Memorial Hospital, Bombay (India); Castillo, M. [Dept. of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-07-01

    We reviewed the pattern of involvement of the calvarium by tuberculosis (TB) in five patients and the role of imaging in its management. Four patients presented with localised scalp swelling and one with generalized seizures. Radiographs revealed lucent lesions with minimal surrounding sclerosis in the frontal (2), parietal (2) and occipital (1) bones. CT showed lesions involving the entire thickness of the calvarium and accompanying contrast-enhancing soft tissue. The patient presenting with seizures had a ring-enhancing lesion in the parietal lobe in addition to the extra-axial lesions. Although radiographs in all cases demonstrated calvarial TB, CT showed the extent of the defect, involvement of adjacent soft tissues, and in one case an intra-axial lesion. Radiographs suffice for follow-up of these patients. (orig.)

  1. A radiographic scanning technique for cores

    Science.gov (United States)

    Hill, G.W.; Dorsey, M.E.; Woods, J.C.; Miller, R.J.

    1979-01-01

    A radiographic scanning technique (RST) can produce single continuous radiographs of cores or core sections up to 1.5 m long and up to 30 cm wide. Changing a portable industrial X-ray unit from the normal still-shot mode to a scanning mode requires simple, inexpensive, easily constructed, and highly durable equipment. Additional components include a conveyor system, antiscatter cylinder-diaphragm, adjustable sample platform, developing tanks, and a contact printer. Complete cores, half cores, sample slabs or peels may be scanned. Converting the X-ray unit from one mode to another is easy and can be accomplished without the use of special tools. RST provides the investigator with a convenient, continuous, high quality radiograph, saves time and money, and decreases the number of times cores have to be handled. ?? 1979.

  2. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  3. Pattern of scattered exposure from portable radiographs

    International Nuclear Information System (INIS)

    Concern periodically arises among the nursing and medical staffs of the institution's intensive care unit regarding their occupational exposure to radiation from the many radiographs taken in the unit. The patients are located in open areas or within individual cubicles whose walls are relatively thin and not shielded. To form a data base for educating the nursing/medical staffs and the technologists, the intensity and distribution of scattered exposure from actual radiographs of patients were measured. Comparison was also made with a simple phantom experiment in which the variables could be more precisely controlled

  4. Chromium intensification of a processed dental radiograph

    International Nuclear Information System (INIS)

    This study was undertaken to determine (1) the usefulness of chromium intensifier to improve the diagnostic quality of light radiograph; (2) the effect of chromium intensifier on density contrast; and (3) the effect of various chemical concentrations on density. The following results obtained: 1. CHROMIUM INTENSIFIER is useful for intensifying and improving the diagnostic quality of a light dental radiograph. 2. The degree of intensification can be controlled by varying bleaching time, repeating the processing, varying the proportions of the potassium bicarbonate and hydrochloric acid solutions. 3. The image produced is black and permanent. 4. The intensifier increases density and contrast

  5. Understanding carpal instability: a radiographic perspective.

    Science.gov (United States)

    Kani, Kimia Khalatbari; Mulcahy, Hyojeong; Chew, Felix S

    2016-08-01

    The wrist is disposed to a variety of instability patterns owing to its complex anatomical and biomechanical properties. Various classification schemes have been proposed to describe the different patterns of carpal instability, of which the Mayo classification is the most commonly used. Understanding the concepts and pertinent terminology of this classification scheme is important for the correct interpretation of images and optimal communication with referring physicians. Standard wrist radiographs are the first line of imaging in carpal instability. Additional information may be obtained with the use of stress radiographs and other imaging modalities. PMID:27085694

  6. Radiographic evaluation of Ilizarov distraction techniques

    International Nuclear Information System (INIS)

    The treatment of limb length discrepancies has been revolutionized by the introduction to this country of the Ilizarov distraction frame. Following corticotomy, however, it is difficult to evaluate new bone formation at the distraction site by traditional means, as it may be many weeks before the bone becomes radiographically evident. The authors have examined over 30 cases of Ilizarov distractions using ultrasound (US) as well as plain film evaluation. Their results demonstrate that US is highly effective in depicting the formation of new bone at the distraction site, correlating well with the pathologic process. New bone formation is visualized with US many weeks before it becomes apparent radiographically

  7. The radiographic features of psoriatic arthritis

    International Nuclear Information System (INIS)

    Psoriatic arthritis is a separate and distinct articular disorder with specific radiographic manifestations occurring in a specific distribution. It manifests a severe erosive element, as well as a bone productive element. The erosive changes help to distinguish it from ankylosing spondylitis, and the bone productive changes, from rheumatoid arthritis. The distribution of the changes, that is, preferential involvement of the hands, will help to distinguish it from Reiter's syndrome. In some patients, it is knowledge of the radiographic changes and distribution of these changes that establishes the correct diagnosis of psoriasis

  8. The radiographer's role in child protection: Comparison of radiographers perceptions by use of focus groups

    International Nuclear Information System (INIS)

    The research presented in this paper is taken from a larger study whose aims were to devise a holistic picture of how diagnostic radiographers approach child protection issues and to explore how radiographers and other professionals see the role of radiographers in the chain of evidence in relation to child protection as this applies to children who present at the Imaging Department with suspected non-accidental injuries (NAI). A focus group methodology was used with focus groups being conducted in the United Kingdom and Republic of Ireland. The results indicated that both United Kingdom and Republic of Ireland radiographers agreed that they had a role in child protection; however, they identified a wide interpretation as to the extent of that role. Although radiographers in the United Kingdom and Republic of Ireland work within different legal systems there were themes identified which were common to both countries. Although radiographers referred to a duty to the child as to all patients, no radiographer specifically mentioned the system and child care law under which it is assumed they operate. This research revealed an area which would benefit from more detailed research using a wider audience. However, the study revealed a need for training in relation to possible NAI indicators and the correct procedure for documenting their suspicions and initiating an NAI referral

  9. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  10. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    International Nuclear Information System (INIS)

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 ± 0.6/8.7 ± 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 ± 15/113 ± 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  11. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  12. Lateral cephalometric radiograph versus lateral nasopharyngeal radiograph for quantitative evaluation of nasopharyngeal airway space

    Directory of Open Access Journals (Sweden)

    Suelen Cristina da Costa Pereira

    2014-08-01

    Full Text Available OBJECTIVE: This study compared lateral radiographs of the nasopharynx (LN and lateral cephalometric radiographs (LC used to assess nasopharyngeal airway space in children. MATERIAL AND METHODS: One examiner measured the nasopharyngeal space of 15 oral breathing patients aged between 5 and 11 years old by using LN and LC. Both assessments were made twice with a 15-day interval in between. Intergroup comparison was performed with t-tests (P < 0.05. RESULTS: Comparison between LN and LC measurements showed no significant differences. CONCLUSION: Lateral cephalometric radiograph is an acceptable method used to assess nasopharyngeal airway space.

  13. Unusual radiographic changes of a gout patient

    International Nuclear Information System (INIS)

    Background. Gout is a metabolic disorder that results in hyperuricemia and accumulation of uric acid crystals (urats) in tissues, especially joint cartilage. The gouty arthritis presents as acute attacks of arthritis leading eventually to chronic gouty arthritis. In 80% of cases it first occurs in the matatarsophalangeal (MTP) joint of the great toe and is more frequent in male population. Case report. We present a case of unusual radiographic changes accompanying gouty arthritis. A 63 year old female complained about swelling of the first MTP joint on the right, right knee, about stiffness of feet and hands' digits and about backache. First symptoms started to appear 30 years ago. In the time of examination radiographs displayed degenerative changes of the majority of presented joints, bilateral sacroiliitis and osseous ankylosis of both insteps. Microscopic examination showed urate crystals in the samples of the synovial fluid aspirated from the knee. The histological findings of the synovial tissue after the synovectomy were also in favour of gouty arthritis. Conclusions. Radiographs are the most important imaging modality in the diagnostic process of gout. However, radiographic differential diagnosis can be difficult, since the findings overlap with other conditions which cause arthritis and osteoarthritis especially in longstanding gout, elderly patients and females. The diagnosis must be often confirmed with the help of laboratory and histological findings. (author)

  14. Radiographic analysis of ameloblastoma: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chandramani More

    2012-01-01

    Conclusion: Radiographs are an important aid for the diagnosis of oral lesions of various types, especially those that involve bone. It is important for the practicing clinicians to know the salient features of ameloblastoma which are peculiar to the local population.

  15. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  16. Algorithms for boundary detection in radiographic images

    International Nuclear Information System (INIS)

    Edge detecting techniques applied to radiographic digital images are discussed. Some algorithms have been implemented and the results are displayed to enhance boundary or hide details. An algorithm applied in a pre processed image with contrast enhanced is proposed and the results are discussed

  17. Guidelines for taking and interpreting radiographs of the bovine foot

    International Nuclear Information System (INIS)

    This step-by-step guide to radiographing the bovine foot tells you how to 1) obtain the radiograph you need, 2) allow for normal variations when assessing the findings, and 3) interpret abnormalities accurately by following a systematic approach

  18. Recognizing the radiographic features of some common bovine foot problems

    International Nuclear Information System (INIS)

    Radiographs of an injured or infected bovine foot can be tricky to interpret - the anatomy is complex, and the signs may be subtle. This guide leads you through the classic radiographic features of several common foot conditions

  19. Surface studies of barium and barium oxide on tungsten and its application to understanding the mechanism of operation of an impregnated tungsten cathode

    Science.gov (United States)

    Forman, R.

    1976-01-01

    Surface studies have been made of multilayer and monolayer films of barium and barium oxide on a tungsten substrate. The purpose of the investigation was to synthesize the surface conditions that exist on an activated impregnated tungsten cathode and obtain a better understanding of the mechanism of operation of such cathodes. The techniques employed in these measurements were Auger spectroscopy and work-function measurements. The results of this study show that the surface of an impregnated cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on oxidized tungsten by evaluating Auger spectra and work-function measurements. Data obtained from desorption studies of barium monolayers on a tungsten substrate in conjunction with Auger and work-function results have been interpreted to show that throughout most of its life an impreganated cathode has a partial monolayer, rather than a monolayer, of barium on its surface.

  20. Design, testing, fabrication and launch support of a liquid chemical barium release payload (utilizing the liquid fluorine-barium salt/hydrazine system)

    Science.gov (United States)

    Stokes, C. S.; Smith, E. W.; Murphy, W. J.

    1972-01-01

    A payload was designed which included a cryogenic oxidizer tank, a fuel tank, and burner section. Release of 30 lb of chemicals was planned to occur in 2 seconds at the optimum oxidizer to fuel ratio. The chemicals consisted of 17 lb of liquid fluorine oxidizer and 13 lb of hydrazine-barium salt fuel mixture. The fuel mixture was 17% barium chloride, 16% barium nitrate, and 67% hydrazine, and contained 2.6 lb of available barium. Two significant problem areas were resolved during the program: explosive valve development and burner operation. The release payload was flight tested, from Wallops Island, Virginia. The release took place at an altitude of approximately 260 km. The release produced a luminous cloud which expanded very rapidly, disappearing to the human eye in about 20 seconds. Barium ion concentration slowly increased over a wide area of sky until measurements were discontinued at sunrise (about 30 minutes).

  1. Image rejects/retakes-radiographic challenges

    International Nuclear Information System (INIS)

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5%. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted

  2. Fractal analysis of weld defect patterns obtained by radiographic tests

    OpenAIRE

    Tesser, J. A.; Lopes, R. T.; Vieira, A. P.; Goncalves, L. L.; Rebello, J. M. A.

    2006-01-01

    This paper presents a fractal analysis of radiographic patterns obtained from specimens with three types of inserted welding defects: lack of fusion, lack of penetration, and porosity. The study focused on patterns of carbon steel beads from radiographs of the International Institute of Welding (IIW). The radiographs were scanned using a greyscale with 256 levels, and the fractal features of the surfaces constructed from the radiographic images were characterized by means of Hurst, detrended-...

  3. Electromagnetic properties of photodefinable barium ferrite polymer composites

    Directory of Open Access Journals (Sweden)

    Olusegun Sholiyi

    2014-07-01

    Full Text Available This article reports the magnetic and microwave properties of a Barium ferrite powder suspended in a polymer matrix. The sizes for Barium hexaferrite powder are 3–6 μm for coarse and 0.8–1.0 μm for the fine powder. Ratios 1:1 and 3:1 (by mass of ferrite to SU8 samples were characterized and analyzed for predicting the necessary combinations of these powders with SU8 2000 Negative photoresist. The magnetization properties of these materials were equally determined and were analyzed using Vibrating Sample Magnetometer (VSM. The Thru, Reflect, Line (TRL calibration technique was employed in determining complex relative permittivity and permeability of the powders and composites with SU8 between 26.5 and 40 GHz.

  4. Barium titanate nanoparticles: promising multitasking vectors in nanomedicine

    Science.gov (United States)

    Graziana Genchi, Giada; Marino, Attilio; Rocca, Antonella; Mattoli, Virgilio; Ciofani, Gianni

    2016-06-01

    Ceramic materials based on perovskite-like oxides have traditionally been the object of intense interest for their applicability in electrical and electronic devices. Due to its high dielectric constant and piezoelectric features, barium titanate (BaTiO3) is probably one of the most studied compounds of this family. Recently, an increasing number of studies have been focused on the exploitation of barium titanate nanoparticles (BTNPs) in the biomedical field, owing to the high biocompatibility of BTNPs and their peculiar non-linear optical properties that have encouraged their use as nanocarriers for drug delivery and as label-free imaging probes. In this review, we summarize all the recent findings about these ‘smart’ nanoparticles, including the latest, most promising potential as nanotransducers for cell stimulation.

  5. HYBRID AND CHARACTERISTIC OF POLYANILINE- BARIUM TITANATE NANOCOMPOSITE PARTICLES

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Polyaniline-barium titanate (PAn-BaTiO3) ultrafine composite particles were prepared by the oxidative polymerization of aniline with H2O2 while barium titanate nanoparticles were synthesized with a sol-gel method. The infrared spectrogram shows that the polymerization of PAn in the hybrid process of PAn-BaTiO3 is similar with the polymeric process of pure aniline, and there is interaction of PAn and BaTiO3 in the PAn-BaTiO3. SEM and TEM results show that the average diameter of the composite particles is 1.50 μm and the diameters of BaTiO3 nanoparticles are 5-15 nm in the composite particle. The electrical conductivity of the ultrafine composite particles is transformable from 100 to 10-11S/cm by equilibrium doping or dedoping method using various concentration of HCl or NaOH solutions.

  6. Thermophysical properties of americium-containing barium plutonate

    International Nuclear Information System (INIS)

    Polycrystalline specimens of americium-containing barium plutonate have been prepared by mixing the appropriate amounts of (Pu0.91Am0.09)O2 and BaCO3 powders followed by reacting and sintering at 1600 K under the flowing gas atmosphere of dry-air. The sintered specimens had a single phase of orthorhombic perovskite structure and were crack-free. Elastic moduli were determined from longitudinal and shear sound velocities. Debye temperature was also determined from sound velocities and lattice parameter measurements. Thermal conductivity was calculated from measured density at room temperature, literature values of heat capacity and thermal diffusivity measured by laser flash method in vacuum. Thermal conductivity of americium-containing barium plutonate was roughly independent of temperature and registered almost the same magnitude as that of BaPuO3 and BaUO3. (author)

  7. Barium titanate nanoparticles: promising multitasking vectors in nanomedicine.

    Science.gov (United States)

    Genchi, Giada Graziana; Marino, Attilio; Rocca, Antonella; Mattoli, Virgilio; Ciofani, Gianni

    2016-06-10

    Ceramic materials based on perovskite-like oxides have traditionally been the object of intense interest for their applicability in electrical and electronic devices. Due to its high dielectric constant and piezoelectric features, barium titanate (BaTiO3) is probably one of the most studied compounds of this family. Recently, an increasing number of studies have been focused on the exploitation of barium titanate nanoparticles (BTNPs) in the biomedical field, owing to the high biocompatibility of BTNPs and their peculiar non-linear optical properties that have encouraged their use as nanocarriers for drug delivery and as label-free imaging probes. In this review, we summarize all the recent findings about these 'smart' nanoparticles, including the latest, most promising potential as nanotransducers for cell stimulation. PMID:27145888

  8. Barium ferrite powders prepared by milling and annealing

    Directory of Open Access Journals (Sweden)

    R. Nowosielski

    2007-05-01

    Full Text Available Purpose: Microstructure and magnetic properties analysis of barium ferrite powder obtained by milling and heat treatment.Design/methodology/approach: The milling process was carried out in a vibratory mill, which generated vibrations of the balls and milled material inside the container during which their collisions occur. After milling process the powders were annealed in electric chamber furnace. The X-ray diffraction methods were used for qualitative phase analysis of studied powder samples. The distribution of powder particles was determined by a laser particle analyzer. The magnetic hysteresis loops of examined powder material were measured by resonance vibrating sample magnetometer (R-VSM.Findings: The milling process of iron oxide and barium carbonate mixture causes decrease of the crystallite size of involved phases. The X-ray investigations of tested mixture milled for 30 hours and annealed at 950 °C enabled the identification of hard magnetic BaFe12O19 phase and also the presence of Fe2O3 phase in examined material. The Fe2O3 phase is a rest of BaCO3 dissociation in the presence of Fe2O3, which forms a compound of BaFe12O19. The best coercive force (HC for mixture of powders annealed at 950 °C for 10, 20 and 30 hours is 349 kA/m, 366 kA/m and 364 kA/m, respectively. The arithmetic mean of diameter of Fe2O3 and BaCO3 mixture powders after 30 hours of milling is about 6.0 μm.Practical implications: The barium ferrite powder obtained by milling and annealing can be suitable components to produce sintered and elastic magnets with polymer matrix.Originality/value: The results of tested barium ferrite investigations by different methods confirm their utility in the microstructure and magnetic properties analysis of powder materials.

  9. Barium borohydride chlorides: synthesis, crystal structures and thermal properties.

    Science.gov (United States)

    Grube, Elisabeth; Olesen, Cathrine H; Ravnsbæk, Dorthe B; Jensen, Torben R

    2016-05-10

    Here we report the synthesis, mechanism of formation, characterization and thermal decomposition of new barium borohydride chlorides prepared by mechanochemistry and thermal treatment of MBH4-BaCl2, M = Li, Na or K in ratios 1 : 1 and 1 : 2. Initially, orthorhombic barium chloride, o-BaCl2 transforms into o-Ba(BH4)xCl2-x, x ∼ 0.15. Excess LiBH4 leads to continued anion substitution and a phase transformation into hexagonal barium borohydride chloride h-Ba(BH4)xCl2-x, which accommodates higher amounts of borohydride, possibly x ∼ 0.85 and resembles h-BaCl2. Thus, two solid solutions are in equilibrium during mechano-chemical treatment of LiBH4-BaCl2 (1 : 1) whereas LiBH4-BaCl2 (2 : 1) converts to h-Ba(BH4)0.85Cl1.15. Upon thermal treatment at T > ∼200 °C, h-Ba(BH4)0.85Cl1.15 transforms into another orthorhombic barium borohydride chloride compound, o-Ba(BH4)0.85Cl1.15, which is structurally similar to o-BaBr2. The samples with M = Na and K have lower reactivity and form o-Ba(BH4)xCl2-x, x ∼ 0.1 and a solid solution of sodium chloride dissolved in solid sodium borohydride, Na(BH4)1-xClx, x = 0.07. The new compounds and reaction mechanisms are investigated by in situ synchrotron radiation powder X-ray diffraction (SR-PXD), Fourier transform infrared spectroscopy (FT-IR) and simultaneous thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), mass spectroscopy (MS) and temperature programmed photographic analysis (TPPA). PMID:27109871

  10. Thermoelectric power of barium up to 8 GPa

    Energy Technology Data Exchange (ETDEWEB)

    Ramani, G.; Divakar, C.; Singh, A.K.

    1987-01-15

    The present measurements indicate that the thermoelectric power (TEP) of barium at room temperature and pressure is 15 ..mu..V K/sup -1/, and decreases with increasing pressure, reaching about 4 ..mu..V K/sup -1/ just before the bcc..-->..hcp transition. The TEP shows a discontinuous increase at the bcc..-->..hcp transition beyond which it continues to decrease with increasing pressure.

  11. Effect of Silver Coating on Barium Titanium Oxide Nanoparticle Toxicity

    OpenAIRE

    Obregon, Isidro D.; Betts-Obregon, Brandi S.; Yust, Brian; Pedraza, Francisco; Ortiz, Alexandra; Sardar, Dhiraj; Tsin, Andrew T.

    2013-01-01

    Nanoparticles are presently being studied for optical and biomedical applications such as medical imaging and drug delivery. Nanoparticles impact the cellular environment due to many variables such as size, shape, and composition. How these factors affect cell viability is not fully understood. The purpose of this study is to test the toxicity effects of silver coating (Ag@) Barium Titanium Oxide (BaTiO3) nanoparticles on Rhesus Monkey Retinal Endothelial cells (RhREC’s) in culture. The addit...

  12. Microstructure and magnetic properties of commercial barium ferrite powders

    Directory of Open Access Journals (Sweden)

    R. Nowosielski

    2007-01-01

    Full Text Available Purpose: Microstructural and magnetic properties analysis of commercial barium ferrite powder BaFe12O19.Design/methodology/approach: The X-ray diffraction methods were utilized not only for qualitative andquantitative phase analysis of studied powder sample, but also for the determination of lattice parameters, crystallitesize and the lattice distortion. The Rietveld method was used in the verification of the qualitative phase compositionand in the determination of phase abundance. Hill and Howard procedure was applied for quantitative phaseanalysis. The parameters of the individual diffraction line profiles were determined by PRO-FIT Toraya procedure.The morphology of barium ferrite powders was analyzed using the scanning electron miroscopy (SEM method.The distribution of powder particles was determined by a laser particle analyzer. Moreover, the magnetic hysteresisloop of examined powder material were measured by resonance vibrating sample magnetometer (R-VSM.Findings: The X-ray diffraction analysis revealed the presence of hexagonal BaFe12O19 and rhombohedralFe2O3 phases in examined powder samples. The barium ferrite phase appeared to be the main component of thesamples (97.8 wt.%. The crystallite size of BaFe12O19 phase is above 100 nm. The size of studied powders isin the range from 0.2 μm to 40.5 μm. The arithmetic mean diameter of BaFe12O19 powders population is 10.335μm. The SEM images showed irregular shape and size of powder particles. The coercive force (HC obtainedfrom hysteresis loop has a value about 159 kA/m.Practical implications: Structure analysis of commercial barium ferrite powder is helpful to prepare thismaterial by laboratory methods.Originality/value: The obtained results of investigations by different methods of structure characterizationconfirm their utility in the microstructure analysis of powder materials.

  13. Dielectric Properties of Barium Titanate Prepared by Spark Plasma Sintering

    Czech Academy of Sciences Publication Activity Database

    Ctibor, Pavel; Sedláček, J.; Dopita, M.; Pala, Zdeněk

    Bratislava: Slovak Expert Group of Solid State Chemistry and Physics , 2011 - (Koman, M.; Mikloš, D.), s. 68-69 ISBN 978-80-8134-002-4. [Joint Seminar – Development of materials science in research and education (DMRSE)/21.th./. Kežmarské Žlaby (SK), 29.08.2011-02.09.2011] Institutional research plan: CEZ:AV0Z20430508 Keywords : spark plasma sintering * barium titanate * dielectric properties Subject RIV: JK - Corrosion ; Surface Treatment of Materials

  14. Preparation and Characterization of Nano-particle Substituted Barium Hexaferrite

    OpenAIRE

    Atassi, Yomen; Darwich, Iyad Seyd; Tally, Mohammad

    2014-01-01

    High density magnetic recording requires high coercivity magnetic media and small particle size. Barium hexaferrite has been considered as a leading candidate material because of its chemical stability, fairly large crystal anisotropy and suitable magnetic characteristics. In this work, we present the preparation of the hexagonal ferrite BaFe12O19 and one of its derivative; the Zn-Sn substituted hexaferrite by the chemical co-precipitation method. The main advantage of this method on the conv...

  15. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used...

  16. 10 CFR 34.46 - Supervision of radiographers' assistants.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Supervision of radiographers' assistants. 34.46 Section 34... REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.46 Supervision of... personal supervision of a radiographer. The personal supervision must include: (a) The...

  17. Microwave-hydrothermal synthesis of barium strontium titanate nanoparticles

    International Nuclear Information System (INIS)

    Research highlights: → Barium strontium titanate nanoparticles were obtained by the Hydrothemal microwave technique (HTMW) → This is a genuine technique to obtain nanoparticles at low temperature and short times → Barium strontium titanate free of carbonates with tetragonal structure was grown at 130 oC. - Abstract: Hydrothermal-microwave method (HTMW) was used to synthesize crystalline barium strontium titanate (Ba0.8Sr0.2TiO3) nanoparticles (BST) in the temperature range of 100-130 oC. The crystallization of BST with tetragonal structure was reached at all the synthesis temperatures along with the formation of BaCO3 as a minor impurity at lower syntheses temperatures. Typical FT-IR spectra for tetragonal (BST) nanoparticles presented well defined bands, indicating a substantial short-range order in the system. TG-DTA analyses confirmed the presence of lattice OH- groups, commonly found in materials obtained by HTMW process. FE/SEM revealed that lower syntheses temperatures led to a morphology that consisted of uniform grains while higher syntheses temperature consisted of big grains isolated and embedded in a matrix of small grains. TEM has shown BST nanoparticles with diameters between 40 and 80 nm. These results show that the HTMW synthesis route is rapid, cost effective, and could serve as an alternative to obtain BST nanoparticles.

  18. Preparation of Nanoparticles of Barium Ferrite from Precipitation in Microemulsions

    International Nuclear Information System (INIS)

    Magnetic nanoparticles of barium ferrite (BaFe12O19) have been synthesized using a microemulsion mediated process. The aqueous cores of water-in-oil microemulsions were used as constrained microreactors for the precipitation of precursor carbonate and hydroxide particles. These precursors were then calcined at 925 deg. C for 12 h, during which time they were transformed to the hexagonal ferrite. The pH of reaction was varied between 5 and 12, and it was found that the fraction of non-magnetic hematite (α-Fe2O3) in the particles varied with the pH of reaction, thus affecting the magnetic properties of the particles. The same precursor particles were also prepared by bulk co-precipitation reaction for comparison. It was found that the microemulsion derived nanoparticles of barium ferrite had both higher intrinsic coercivity (Hc) and saturation magnetization (σs) than the particles derived from bulk co-precipitation. Particles were analyzed by electron microscopy, X-ray diffraction, differential thermal analysis (DTA), thermogravimetric analysis (TGA) and vibrating sample magnetometry (VSM). The best barium ferrite particles produced by the microemulsion synthesis method yielded an intrinsic coercivity of 4310 Oe and a saturation magnetization of 60.48 emu/g

  19. Role of hexadecapole interaction in proton rich barium isotopes

    International Nuclear Information System (INIS)

    From the systematic analysis of the experimental data on proton rich barium isotopes, it is observed that nuclei in the region z ≥ 50 and N≤82 are the transitional nuclei as they show a shape transition from spherical to deformed shape. An interesting feature of the observed yrast spectra in barium isotopic mass chain is the systematic variation of E2+, E4+ and E6+ excitation energy states from 120Ba to 136Ba. It is observed that these states follow a systematic decreasing trend as move away from 136Ba towards 120Ba. The isotopes 120-128Ba can be taken to be quasi-deformed nuclei having E4+/E2+ ratio larger than 2.7. Based on the systematics of low-lying states and the experimental data of quadrupole moments and B(E2) transition probabilities, the stable barium isotopes range from the approximately spherical 138Ba to l30Ba which is close to the deformed 120-128Ba isotopes. The purpose of the paper is to determine the importance of octupole-octupole and hexadecapole- hexadecapole parts of the two body interaction in reproducing the observed nuclear structure properties of 120-136Ba isotopes

  20. CT and barium features of gastrointestinal and peritoneal tuberculosis

    Directory of Open Access Journals (Sweden)

    Makanjuola Dorothy

    1997-01-01

    Full Text Available The radiological features in barium gastrointestinal studies and computed tomographic (CT examinations of 22 consecutive cases of proven peritoneal and/or intestinal tuberculosis were analyzed in order to highlight the radiological features which could provide ready identification of the disease. There were 15 cases of intestinal tuberculosis and 7 cases of peritoneal tuberculosis and 3 patients had both. The commonest location of intestinal tuberculosis was the ileocecal region (N=10 which occurred in association with colonic or ilea] disease. Bowel wall thickening in CT was largely asymmetrical but minimal and symmetrical wall thickening occurred with peritonitis. Luminal narrowing with or without mucosal tethering were seen in both CT and Barium studies. Peritoneal TB had either high density ascites with smudge or nodular omental surface with a thickened omental lining. Also detected was fibrinous dry peritonitis with thickened mesenteric tissue. Lymphadenopathy in the peripancreatic, mesenteric or paracaval were common to both intestinal or peritoneal tuberculosis (21 out of 22. Fifty percent of the patients showed some lymph nodes with necrotic centers. The differential diagnosis included malignant peritonitis and intestinal or mesenteric carcinoid. The study shows that a combination of barium gastrointestinal study and computed tomography can provide distinct features which could strongly suggest the diagnosis of intestinal or peritoneal tuberculosis.

  1. Scanning electron and tunneling microscopy of palladium-barium emitters

    International Nuclear Information System (INIS)

    The results of study of metal-alloyed palladium-barium emitters' of modern very high frequency high-powered electronic vacuum tubes by scanning electron microscopy (SEM) and scanning tunneling microscopy/spectroscopy (STM/STS) are presented. Since the Pd/Ba foil surface is fairly smooth and is not oxidized in air STM/STS investigations are carried out in air in normal laboratory environment. SEM and STM images show that the emitter surface has a complex porous structure. The cathode surface study by STS in tunneling gap modulation mode allowed to take a map of phase distribution with various work function values and high lateral resolution. Obtained images demonstrate the presence of three phases on the Pd/Ba emitter surface, viz. barium-oxygen compounds, intermetallic, and palladium. As it is seen from presented STS image the phase with a low work function value (barium oxides) is concentrated along boundaries of the substance inclusions with work function corresponding to the intemetallic compound Pd5Ba. This supports the model of low work function areas obtained via Ba segregation from the intermetallic compound and oxidation. The presented methods may be used in the Pd/Ba cathode manufacturing process for increasing the yield of electronic devices in microwave tube production and optimize the emitters' characteristics

  2. Early colon cancer : findings on double contrast barium enema

    International Nuclear Information System (INIS)

    The purpose of this study is to describe the radiologic findings of early colon cancer on double-contrast barium enema. We retrospectively reviewed the double-contrast barium enemas of eight patients (M:F = 6:2; mean age : 67 yrs; range : 48-77 yrs) who were pathologically proven to be early colon cancer. The location, size and gross morphology of lesions was evaluated using double-contrast barium enema, while depth of invasion, degree of differentiation, precancerous lesions and lymph node metastasis were evaluated histopathologically. Early colon cancer was found in the rectum (n=4), sigmoid colon (n=3) and ascending colon (n=1). The size of mass ranged from 2.3 ∼ 8.3 (mean, 4.6) cm. And the polypoid type was most common (n=7); this was subdivided into sessile (Is, n=5), semipedunculated (Isp, n=1) and pedunculated type (Ip, n=1). Another mass was a sessile polypoid combined with a flat depressed lesion. In eight cases, four cancers were confined to the mucosa, while the remaining four had infiltrated the submucosa. Most cancers arose from villous and villotubular adenoma. All cases were well-differentiated adenocarcinoma and no metastasis to lymph nodes had occurred. In early colon cancer, lesions were mainly polypoid and large. Most arose from villous and villotubular adenoma. (author). 19 refs., 1 tab., 3 figs

  3. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    International Nuclear Information System (INIS)

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation

  4. Effect of radiographic contrast agents on leukocyte metabolic response

    International Nuclear Information System (INIS)

    Barium, at clinical dilutions, causes a significant increase of baseline ''resting state'' phagocytic activity, which in turn leads to significant blunting of subsequent response to phagocytic challenge and adversely affects the response to all bacteria tested. There is no baseline activation of leukocytes by the water-soluble media, although there was some inhibition (rather than activation) of leukocyte metabolic activity. The effect of the water-soluble media in bacteria was more complex (although inhibition is minor compared to barium). Our data demonstrate that barium is a significant activator of phagocytic cells, which results in deactivation of phagocytic response when challenged; these data serve to explain the enhanced adverse effect of barium in cased of fecal peritonitis. (orig.)

  5. Barium and Tc-poor S stars: Binary masqueraders among carbon stars

    OpenAIRE

    Jorissen, A; Van Eck, S.

    1997-01-01

    The current understanding of the origin of barium and S stars is reviewed, based on new orbital elements and binary frequencies. The following questions are addressed: (i) Is binarity a necessary condition to produce a barium star? (ii) What is the mass transfer mode (wind accretion or RLOF?) responsible for their formation? (iii) Do barium stars form as dwarfs or as giants? (iv) Do barium stars evolve into Tc-poor S stars? (v) What is the relative frequency of Tc-rich and Tc-poor S stars?

  6. Mechanism of action of barium ion on rat aortic smooth muscle.

    Science.gov (United States)

    Hansen, T R; Dineen, D X; Petrak, R

    1984-03-01

    The mechanism of action of barium ion on the aortic smooth muscle of the normal rat was investigated using in vitro calcium-depleted aortic strips. Aortic strips were depleted of calcium by repeated exposure to norepinephrine in a calcium-free bathing solution. Although calcium depletion abrogated the response of strips to catecholamines and depolarizing agents, the response to barium chloride remained quantitatively intact. The calcium influx blocker D 600 prevented the contractile response to barium but not to catecholamines, whereas phentolamine prevented the response to catecholamines but not barium. The strip response to barium was depressed by a twofold increase in extracellular magnesium concentration whether the strip was intact or calcium depleted. Although increased concentrations of calcium in the extracellular medium inhibited the contractile response to potassium ion, increases in barium merely potentiated the potassium contracture. These findings indicate that barium produces its contractile effect on vascular smooth muscle by a direct intracellular interaction with the contractile or regulatory proteins. Barium enters these cells via calcium influx channels and is probably not sequestered in a physiologically releasable pool. Unlike calcium, barium does not stabilize the smooth muscle sarcolemma when present in high concentration. PMID:6703038

  7. Barium can replace calcium in calmodulin-dependent contractions of skinned renal arteries of the rabbit.

    Science.gov (United States)

    Kreye, V A; Hofmann, F; Mühleisen, M

    1986-03-01

    Renal arteries of the rabbit were chemically skinned using Triton X-100. In EGTA-buffered solutions containing calmodulin and ATP, small strips of the skinned preparations were found to develop contractile force which was dependent on the concentrations of either free calcium or of free barium. However, a 220 times greater concentration of barium than of calcium was necessary for comparable effects. Quantitatively, the response to barium was dependent on the concentration of calmodulin added to the test solutions. The contractile effect of barium was partly antagonized by the calmodulin antagonist, trifluoperazine. PMID:3960707

  8. High Resolution Computed Tomography Appearences of late sequelae of Barium Aspiration in an asymptomatic young child

    International Nuclear Information System (INIS)

    Barium aspiration is a well-known complication of upper gastro-intestinal studies. Consequences of aspiration are generally insignificant and leave no permanent changes in the lung parenchyma. However, large quantities of high density barium, if aspirated, lead to silent interstitial changes and fibrosis. High-resolution computed tomography HRCT appearances of lung changes have been demonstrated in adults; few such reports are available in the pediatric literature. We report a case of a child who aspirated barium 3 months before this presentation. The HRCT appearances of barium aspiration are presented with a review of the literature. (author)

  9. Assessment of fast radiographic systems by the constant exposure technique

    International Nuclear Information System (INIS)

    The constant exposure technique was applied to compare the radiographic image quality and relative speed of different fast radiographic systems. Conventional industrial X-ray films, exposed with lead intensifying screens, special fast film with fluorometallic screens as well as different brands of radiographic paper exposed both with fluorescent as well as fluorometallic screens were tested and compared. ISO wire IQI's and ASTM penetrameters were used together with 30-mm aluminium and 10-mm steel plates. For all the fast radiographic systems wire sensitivity better than 2 per cent was obtained. The constant exposure technique proved to be adequate for the assessment of fast radiographic systems. (author)

  10. An Applied Image Processing for Radiographic Testing

    International Nuclear Information System (INIS)

    An applied image processing for radiographic testing (RT) is desirable because it decreases time-consuming, decreases the cost of inspection process that need the experienced workers, and improves the inspection quality. This paper presents the primary study of image processing for RT-films that is the welding-film. The proposed approach to determine the defects on weld-images. The BMP image-files are opened and developed by computer program that using Borland C++. The software has five main methods that are Histogram, Contrast Enhancement, Edge Detection, Image Segmentation and Image Restoration. Each the main method has the several sub method that are the selected options. The results showed that the effective software can detect defects and the varied method suit for the different radiographic images. Furthermore, improving images are better when two methods are incorporated

  11. Radiographic examination of the equine stifle

    International Nuclear Information System (INIS)

    A radiographic technique is described for the equine stifle joint with the horse in the standing position or under general anaesthesia. The method with the animal anaesthetised in the dorsal recumbency and the leg extended was preferred because it gave greater flexibility with a better range of views and greatly reduced the safety hazards. In the standing position a useful practical tip for the lateral view was to raise and extent the limb caudally. This provides some flexion and ventral movement of the stifle allowing improved access for the cassette, a more accurate lateral view of the joint and a reduction in exposure. Some of the features of radiographic anatomy, from birth to adulthood, of this rather complex joint are described to form a basis for radiological interpretation in cases of suspected stifle lameness

  12. Clinical and radiographic maxillofacial features of pycnodysostosis

    OpenAIRE

    Alves, Nilton; Cantín, Mario

    2014-01-01

    The aim of this study was to review of the literature to determine the radiographic and clinical maxillofacial features of pycnodysostosis emphasizing the main aspects of interest to the dentist in order to make them fit for the proper treatment of this population. It is important to make the diagnosis as early as possible in order to plan the treatment more suitable to provide a better life’s quality to the patients. The most frequent clinical maxillofacial features were: grooved palate, mid...

  13. Video enhancement of dental radiographic films

    International Nuclear Information System (INIS)

    A prototype video image display system, a real-time analog enhancer (RAE), was compared to conventional viewing conditions with the use of nonscreen dental films. When medium optical density films were evaluated, there was no significant difference in the number of radiographic details detected. Conventional viewing conditions allowed perception of more details when dark films were evaluated; however, the RAE unit allowed the perception of more details when light films were viewed

  14. Radiographic imaging of the canine intercondylar fossa

    International Nuclear Information System (INIS)

    The intercondylar fossa is believed to play an important role in the pathology of cranial cruciate ligament rupture and therefore has received considerable attention in the last decade. Accurate radiographic imaging of the intercondylar fossa requires that the central x-ray beam pass through the center of the intercondylar “tunnel”. The anatomy of the canine intercondylar fossa is similar to humans, however, the orientations of the intercondylar fossa's differ. Consequently, the positioning techniques described for humans are not appropriate for the dog. To pass through the center of the dog, intercondylar fossa, the central x-ray beam should be 12° (S.D. 1.7°) caudal from the femoral diaphysis in the sagittal plane and obliqued caudolateral to craniomedial 7° (S.D. 0.60°) (caudo78°proximo7° lateralcraniodistomedial oblique). Cross table positioning was used with the hip flexed and the radiograph cassette placed on the cranial surface of the stifle. However, superimposition of the tuber ischii and soft tissues caudal to the femur made 15° to 20° the best angle obtainable. There was not a significant difference (p = 0.17) in the notch width index between a 12° versus 20° angle of the central x-ray beam caudal to the femoral diaphysis, both with 7° of external rotation of the stifle. The notch width index of 0.252 obtained from radiographic measurements was not significantly different from measurements obtained grossly of 0.254 (n = 26; p = 0.69). Failure to oblique the central x-ray beam caused a significant (p = 0.0008) decrease in the apparent fossa width radiographically

  15. Adverse Reactions to Radiographic Contrast Material

    OpenAIRE

    Bush, William H.; Mullarkey, Michael F.; Webb, D. Robert

    1980-01-01

    Major adverse reactions to radiographic contrast media will occur more often as contrast material is now also administered during computerized tomographic (CT) scanning. Differentiation of the two major contrast reactions, the vagus reaction and the anaphylactoid reaction, is essential. Bradycardia is the key finding for identifying the vagus reaction. The vagus reaction involving hypotension and bradycardia requires treatment with large doses of atropine given intravenously. The immediate ge...

  16. Burnout in therapy radiographers in the UK

    OpenAIRE

    Probst, H; Griffiths., S; Adams, R; Hill, C

    2012-01-01

    The 2007 UK National Radiotherapy Advisory Group report indicated that the number and type of staff available is one of the “rate-limiting” steps in improving productivity in radiotherapy departments. Retaining well-trained, satisfied staff is key to meeting the objectives of the report; burnout is an important factor linked to satisfaction and attrition. The results of a survey measuring burnout in a sample of radiotherapists (therapy radiographers) are presented and considered against norms...

  17. Radiographic assessment of knee joint rotation.

    OpenAIRE

    Straiton, J A; Todd, B; Venner, R M

    1987-01-01

    A radiographic technique for measuring conjunct rotation at the knee joint is described. Conjunct rotation was demonstrated to occur over a greater range of values of flexion than conventionally believed. Rotation increased progressively as the knee extended, and was not confined to the last phase of extension. Consideration of such rotatory movement is relevant to the design of knee arthroplasties and also to possible mechanisms of non-bony injury of the knee.

  18. Iterative Reconstruction of Coded Source Neutron Radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Bingham, Philip R [ORNL; Gregor, Jens [University of Tennessee, Knoxville (UTK)

    2012-01-01

    Use of a coded source facilitates high-resolution neutron imaging but requires that the radiographic data be deconvolved. In this paper, we compare direct deconvolution with two different iterative algorithms, namely, one based on direct deconvolution embedded in an MLE-like framework and one based on a geometric model of the neutron beam and a least squares formulation of the inverse imaging problem.

  19. An improved method for simulating radiographs

    International Nuclear Information System (INIS)

    The parameters involved in generating actual radiographs and what can and cannot be modeled are examined in this report. Using the spectral distribution of the radiation source and the mass absorption curve for the material comprising the part to be modeled, the actual amount of radiation that would pass through the part and reach the film is determined. This method increases confidence in the results of the simulation and enables the modeling of parts made of multiple materials

  20. Scintigraphic and radiographic findings in Caroli's disease

    International Nuclear Information System (INIS)

    In recent years, noninvasive evaluation of Caroli's disease has been demonstrated by computed tomography, ultrasonography, and nuclear scintigraphy. Confirmation of Caroli's disease requires invasive procedures such as percutaneous transhepatic cholangiography or endoscopic retrograde cholangiography. All of the techniques give valuable information making it easier to diagnose Caroli's disease and to determine its extent. In addition, associated abnormalities in organs outside of the biliary system may be revealed. Two cases are presented to illustrate the radiographic and scintigraphic findings of Caroli's disease

  1. Possibilities of radiographic digitalisation in dental clinics

    International Nuclear Information System (INIS)

    In the evolution diagnostic processes by image, the improvement of the intrabucal radiographic sensibility generated and digitalized is today, of great expressiveness in the evolution and effectiveness in the odontological area. This methodology applicability as a possibility of a more precise and accurate diagnostic formulation among other advantages, justifies this technique use. This paper intends to, thorough the literature magazine and clinic case presentations to show its applicability in the daily odontological clinic, and specially, in the periodonty area. (author)

  2. The equine flexed lateral fetlock radiographic view

    International Nuclear Information System (INIS)

    Recommendations for obtaining the flexed lateral radiographic view of the equine fetlock are provided. By tilting the X-ray tube in a 10-degrees dorsal direction, the angle of the flexed lateral fetlock joint is matched. While this view will not be effective on all horses, utilizing the flexed view aids in evaluating those horses that present an abnormal conformation when the fetlock joint is flexed

  3. Accuracy of radiographer reporting of paediatric brain CT

    International Nuclear Information System (INIS)

    Radiographer reporting has been studied for plain films and for ultrasonography, but not in paediatric brain CT in the emergency setting. To study the accuracy of radiographer reporting in paediatric brain CT. We prospectively collected 100 paediatric brain CT examinations. Films were read from hard copies using a prescribed tick sheet. Radiographers with 12 years' and 3 years' experience, respectively, were blinded to the history and were not trained in diagnostic film interpretation. The radiographers' results were compared with those of a consultant radiologist. Three categories were defined: abnormal scans, significant abnormalities and insignificant abnormalities. Both radiographers had an accuracy of 89.5% in reading a scan correctly as abnormal, and radiographer 1 had a sensitivity of 87.8% and radiographer 2 a sensitivity of 96%. Radiographer 1 had an accuracy in detecting a significant abnormality of 75% and radiographer 2 an accuracy of 48.6%, and the sensitivities for this category were 61.6% and 52.9%, respectively. Results for detecting the insignificant abnormalities were poorer. Selected radiographers could play an effective screening role, but lacking the sensitivity required for detecting significant abnormality, they could not be the final diagnostician. We recommend that the study be repeated after both radiographers have received formal training in interpretation of paediatric brain CT. (orig.)

  4. Solubility and stability of barium arsenate and barium hydrogen arsenate at 25oC

    International Nuclear Information System (INIS)

    The inconsistency among current thermodynamic data of Ba3(AsO4)2(c) and BaHAsO4.H2O(c) led the authors to obtain independent solubility data of barium arsenate by both precipitation and dissolution experiments. Low and neutral pH (3.63-7.43) favored the formation of BaHAsO4.H2O(c). Both BaHAsO4.H2O(c) and Ba3(AsO4)2(c) formed at the neutral pH conditions (7.47, 7.66), whereas Ba3(AsO4)2(c) was the only solid phase precipitated at high pH (13.03, 13.10). The Ba3(AsO4)2(c) precipitate acquired at 50oC appeared as small leafy crystal, while the Ba3(AsO4)2(c) solid precipitated at 25oC comprised granular aggregate with some smaller crystal clusters. XRD and SEM analyses of Ba3(AsO4)2(c) and BaHAsO4.H2O(c) indicated that the solids were indistinguishable before and after the dissolution experiments. In the present work, the solubility products (Ksp) for Ba3(AsO4)2(c) and BaHAsO4.H2O(c) were determined to be 10-23.53(10-23.01 to 10-24.00) and 10-5.60(10-5.23 to 10-5.89), respectively. ΔGfo for Ba3(AsO4)2(c) and BaHAsO4.H2O(c) were calculated to be -3113.40 and -1544.47kJ/mol, respectively. There was no difference between the solubility products of the leafy and the granular Ba3(AsO4)2(c) solids

  5. Tungsten and barium transport in the internal plasma of hollow cathodes

    Science.gov (United States)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2009-06-01

    The effect of tungsten erosion, transport, and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from 8200 h and 30 352 h ion engine wear tests. Erosion and subsequent redeposition of tungsten in the electron emission zone at the downstream end of the insert reduce the porosity of the tungsten matrix, preventing the flow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  6. Accuracy of radiographers red dot or triage of accident and emergency radiographs in clinical practice: a systematic review

    International Nuclear Information System (INIS)

    AIM: To determine the accuracy of radiographers red dot or triage of accident and emergency (A and E) radiographs in clinical practice. MATERIALS AND METHODS: Eligible studies assessed radiographers red dot or triage of A and E radiographs in clinical practice compared with a reference standard and provided accuracy data to construct 2x2 tables. Data were extracted on study eligibility and characteristics, quality, and accuracy. Pooled sensitivities and specificities and chi-square tests of heterogeneity were calculated. RESULT: Three red dot and five triage studies were eligible for inclusion. Radiographers' red dot of A and E radiographs in clinical practice compared with a reference standard is 0.87 [95% confidence interval (CI) 0.85-0.89] and 0.92 (0.91-0.93) sensitivity and specificity, respectively. Radiographers' triage of A and E radiographs of the skeleton is 0.90 (0.89-0.92) and 0.94 (0.93-0.94) sensitivity and specificity, respectively; and for chest and abdomen is 0.78 (0.74-0.82) and 0.91 (0.88-0.93). Radiographers' red dot of skeletal A and E radiographs without training is 0.71 (0.62-0.79) and 0.96 (0.93-0.97) sensitivity and specificity, respectively; and with training is 0.81 (0.72-0.87) and 0.95 (0.93-0.97). Pooled sensitivity and specificity for radiographers without training for the triage of skeletal A and E radiographs is 0.89 (0.88-0.91) and 0.93 (0.92-0.94); and with training is 0.91 (0.88-0.94) and 0.95 (0.93-0.96). CONCLUSION: Radiographers red dot or triage of A and E radiographs in clinical practice is affected by body area, but not by training

  7. Anion and cation diffusion in barium titanate and strontium titanate

    International Nuclear Information System (INIS)

    Perovskite oxides show various interesting properties providing several technical applications. In many cases the defect chemistry is the key to understand and influence the material's properties. In this work the defect chemistry of barium titanate and strontium titanate is analysed by anion and cation diffusion experiments and subsequent time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reoxidation equation for barium titanate used in multi-layer ceramic capacitors (MLCCs) is found out by a combination of different isotope exchange experiments and the analysis of the resulting tracer diffusion profiles. It is shown that the incorporation of oxygen from water vapour is faster by orders of magnitude than from molecular oxygen. Chemical analysis shows the samples contain various dopants leading to a complex defect chemistry. Dysprosium is the most important dopant, acting partially as a donor and partially as an acceptor in this effectively acceptor-doped material. TEM and EELS analysis show the inhomogeneous distribution of Dy in a core-shell microstructure. The oxygen partial pressure and temperature dependence of the oxygen tracer diffusion coefficients is analysed and explained by the complex defect chemistry of Dy-doped barium titanate. Additional fast diffusion profiles are attributed to fast diffusion along grain boundaries. In addition to the barium titanate ceramics from an important technical application, oxygen diffusion in cubic, nominally undoped BaTiO3 single crystals has been studied by means of 18O2/16O2 isotope exchange annealing and subsequent determination of the isotope profiles in the solid by ToF-SIMS. It is shown that a correct description of the diffusion profiles requires the analysis of the diffusion through the surface space-charge into the material's bulk. Surface exchange coefficients, space-charge potentials and bulk diffusion coefficients are analysed as a function of oxygen partial pressure and temperature. The data

  8. Microstructure of polymer composite with barium ferrite powder

    Directory of Open Access Journals (Sweden)

    R. Nowosielski

    2008-12-01

    Full Text Available Purpose: The aim of the paper is the microstructure characterization of commercial BaFe12O19 powder and its composite material in polymer matrix; XRD (X-Ray Diffraction and SEM (Scanning Electron Microscopy methods were applied.Design/methodology/approach: The Rietveld method appeared to be very useful in the verification of the qualitative phase composition and in the determination of phase abundance. Hill and Howard procedure was applied for quantitative phase analysis. The parameters of the individual diffraction line profiles were determined by PRO-FIT Toraya procedure. The morphology of barium ferrite powders and a fracture surface of the examined composite material was analyzed using the scanning electron microscope.Findings: The X-ray diffraction analysis enabled the identification of BaFe12O19 and Fe2O3 phases in examined material. Basing on Rietveld and Toraya methods the determination of lattice parameters, crystallite size and the lattice distortion was performed. Distribution of powders of barium ferrite in polymer matrix is irregular and powder particles are of irregular shapes and different sizes.Research limitations/implications: Maked researches are limited only to characterization the microstructure of commercial material, because obtained results will be helpful to prepare barium ferrite powders by mechanical alloying and subsequent annealing in the future. As prepared BaFe12O19 powders will be used as the starting material for magnets bonded with polymer material.Originality/value: The obtained results of investigations by different methods of structure analysis confirm their useful in the microstructure analysis of powder materials.

  9. 75 FR 36629 - Barium Chloride From the People's Republic of China: Continuation of Antidumping Duty Order

    Science.gov (United States)

    2010-06-28

    ... Barium Chloride From China, 75 FR 33824 (June 15, 2010), and Barium Chloride from China (Inv. No. 731-TA... Five-year (``Sunset'') Review, 74 FR 31412 (July 1, 2009). As a result of its review, the Department... China: Final Results of Expedited Third Sunset Review of Antidumping Duty Order, 74 FR 55814 (October...

  10. New efficient catalyst for ammonia synthesis: barium-promoted cobalt on carbon

    DEFF Research Database (Denmark)

    Hagen, Stefan; Barfod, Rasmus; Fehrmann, Rasmus; Jacobsen, Claus J.H.; Teunissen, Herman T; Ståhl, Kenny; Chorkendorff, Ib

    2002-01-01

    Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia......Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia...

  11. LACK OF EFFECT OF DRINKING WATER BARIUM ON CARDIOVASCULAR RISK FACTORS

    Science.gov (United States)

    Higher cardiovascular mortality has been associated in a single epidemiological study with higher levels of barium in drinking water. he purpose of this study was to determine whether drinking water barium at levels found in some U.S. communities alters the known risk factors for...

  12. Acute respiratory failure caused by aspiration of high density barium: A case report

    International Nuclear Information System (INIS)

    Accidental aspiration of barium contrast medium during the upper gastrointestinal study can occur in patients with swallowing disorder, especially in the elderly patients. We experienced a case of respiratory failure followed by death within a few hours in 85 year-old patient after barium aspiration

  13. Small intestinal emptying time in normal Beagle dogs: a contrast radiographic study

    International Nuclear Information System (INIS)

    Gastric emptying time and small intestinal transit time in dogs are frequently discussed. However, it is often of interest to the radiologist to know what normal small intestinal emptying times should be. A total of 15 upper gastrointestinal studies was performed on five internal parasite-free, normal, standard Beagle dogs with three studies on each dog, 6 days apart. The ages and weights of the dogs ranged from 2–8 years and from 12.4–13.7 kg, respectively. Following 24-hour fasting, a dose of 10 ml/kg bw of 60% wt/vol barium sulfate suspension was administered through a stomach tube. Then, sequential radiographs were made at 30-minute intervals until the entire contrast medium column was in the colon and cecum. The mean, standard deviation, and range of gastric emptying time, small intestinal transit time, and small intestinal emptying time were 76 ± 16.7 (30–120), 73 ± 16.4 (30–120), and 214 ± 25.1 (180–300) minutes, respectively. This study offers the possibility that small intestinal emptying time may be used to further evaluate patients with suspected small intestinal partial obstruction, pseudo-obstruction, ischemia, or lymphangiectasia

  14. Medical radiation shielding effect by composition of barium compounds

    International Nuclear Information System (INIS)

    Highlight: ► Radiation shielding sheet was manufactured using BaSO4 and a combination of tourmaline, tungsten, silicon and rubber polymer. ► The particle packing of barium tends to be related to the tensile strength. ► The tensile strength was most excellent in the sheets containing rubber. ► The shielding ability of the tungsten and silicon combination with BaSO4 was the same as that of a 0.3 mm lead equivalent. - Abstract: Shielding aprons were manufactured from barium sulfate as a potential substitute for the lead aprons used most commonly for medical radiation shielding. Six types of radiation shielding sheets made from a combination of tungsten, molybdenum, rubber and silicon with a barium sulfate base were manufactured, and their transmission doses were compared with those of a lead standard. In the process of producing the radiation shielding sheets, the particle packing and porosity of the materials, appropriate weight-average molecular weight to number-average molecular weight ratio and tensile strength were investigated to determine the optimal mixing process. The transmission dose was measured by applying a lead equivalent test method () of X-ray protective supplies in the Korea Industrial Standard. The transmission doses of the lead standard with a thickness of 0.05, 0.1, 0.15, 0.2, 0.25, 0.3 and 0.35 mm, as well as the six types of radiation shielding sheet were obtained at a tube voltage of 50, 80, 100, 120 and 150 kVp. According to the results, the combination of barium, tungsten, molybdenum and silicon recorded a dose of a 0.3 mm lead equivalent and its particle packing and porosity were 28–36% and 12–22%, respectively. Nevertheless, satisfactory shielding ability could be obtained with a porosity >20% and particle packing of 30%. Therefore, it is a potential replacement for lead sheet and can be considered a proper medical radiation shielding sheet with good economic feasibility.

  15. Enhanced flexoelectricity through residual ferroelectricity in barium strontium titanate

    International Nuclear Information System (INIS)

    Residual ferroelectricity is observed in barium strontium titanate ceramics over 30 °C above the global phase transition temperature, in the same temperature range in which anomalously large flexoelectric coefficients are reported. The application of a strain gradient leads to strain gradient-induced poling or flexoelectric poling. This was observed by the development of a remanent polarization in flexoelectric measurements, an induced d33 piezoelectric response even after the strain gradient was removed, and the production of an internal bias of 9 kV m−1. It is concluded that residual ferroelectric response considerably enhances the observed flexoelectric response

  16. Strain engineered barium strontium titanate for tunable thin film resonators

    Energy Technology Data Exchange (ETDEWEB)

    Khassaf, H.; Khakpash, N. [Department of Materials Science and Engineering and Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269 (United States); Sun, F. [Department of Physics, University of Connecticut, Storrs, Connecticut 06269 (United States); Sbrockey, N. M.; Tompa, G. S. [Structured Materials Industries, Inc., Piscataway, New Jersey 08854 (United States); Kalkur, T. S. [Department of Electrical and Computer Engineering, University of Colorado at Colorado Springs, Colorado Springs, Colorado 80918 (United States); Alpay, S. P., E-mail: p.alpay@ims.uconn.edu [Department of Materials Science and Engineering and Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269 (United States); Department of Physics, University of Connecticut, Storrs, Connecticut 06269 (United States)

    2014-05-19

    Piezoelectric properties of epitaxial (001) barium strontium titanate (BST) films are computed as functions of composition, misfit strain, and temperature using a non-linear thermodynamic model. Results show that through adjusting in-plane strains, a highly adaptive rhombohedral ferroelectric phase can be stabilized at room temperature with outstanding piezoelectric response exceeding those of lead based piezoceramics. Furthermore, by adjusting the composition and the in-plane misfit, an electrically tunable piezoelectric response can be obtained in the paraelectric state. These findings indicate that strain engineered BST films can be utilized in the development of electrically tunable and switchable surface and bulk acoustic wave resonators.

  17. Heterometallic β-diketonates containing barium and rare earth elements

    International Nuclear Information System (INIS)

    Potentiality of formation of heterobimetallic complexes of the composition Ba[LnLn] (Ln = La, Er; L - hexafluoroacetylacetonate, pivaloyltrifluoroacetonate-(Pta), dipivaloylmethanate-anion, is studied by mass spectrometry (MALDI-MS) method. The compounds prepared are characterized by the methods of element analysis. IR spectroscopy of gaseous phase, thermal analysis in vacuum. Compound Ba[La(Pta)5] features increased thermal stability compared with Ba(Pta)2 and La(Pta)3 and it can be offered for practical use as barium and lanthanum source in preparation of oxide films

  18. Barium strontium titanate powders prepared by spray pyrolysis

    International Nuclear Information System (INIS)

    Ultasonic spray pyrolysis (SP) has been investigated for the production of the barium strontium titanate (BST) powders from the polymeric precursors. The processing parameters, such as flux of aerosol and temperature profile inside the furnace, were optimized to obtain single phase BST. The powders were characterized by the methods of X-ray diffraction analysis, SEM, EDS and TEM. The obtained powders were submicronic, consisting of spherical, polycrystalline particles, with internal nanocrystalline structure. Crystallite size of 10 nm, calculated using Rietveld refinement, is in a good agreement with results of HRTEM

  19. Mechanism of thermoluminescence in europium-doped barium fluorochloride

    International Nuclear Information System (INIS)

    The paper concerns the optical properties of europium-doped barium fluorochloride. Thermoluminescence (TL) and emission studies have been carried out with this material and the results are reported. The irradiation was by γ-rays from a 60Co source, the dose rate being 5000rad min-1. Glow curves of γ-irradiated BaFCl:Eu2+ are presented, along with the glow curves resolved into component peaks. TL emission spectra of BaFCl:Eu2+ at room temperature, 345K, 395K and 500K are also described. (U.K.)

  20. The Kerr nonlinearity of the beta-barium borate crystal

    OpenAIRE

    Bache, Morten; Guo, Hairun; Zhou, Binbin; Zeng, Xianglong

    2013-01-01

    A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond experiments BBO is popular because of low dispersion and a high damage threshold. The main attractive property of ultrafast cascading is that the induced cascading nonlinearity nI 2, casc can be negative, i.e...

  1. K-shell fluorescence yields of barium and lanthanum

    International Nuclear Information System (INIS)

    K-shell fluorescence yields for barium and lanthanum have been measured adopting simple 2π geometrical configuration and employing a weak 57Co radioactive source. A scintillation spectrometer with an NaI(Tl) detector of dimensions 44.5 mm diameterx50 mm thickness was employed for the detection and measurement of radiation. The results obtained are in good agreement with the best-fitted values of and also with the other experimental values, indicating that our simple method can be extended to determine fluorescence parameters of high Z materials.

  2. Colloidal stability of aqueous suspensions of barium zirconate

    OpenAIRE

    Boschini, Frédéric; Rulmont, André; Cloots, Rudi; Moreno, R.

    2005-01-01

    In this article, the colloidal behaviour of aqueous suspensions of barium zirconate is investigated. The variation of zeta-potential as a consequence of changing the pH and the concentration of an anionic polyelectrolyte is studied, the isoelectric point occurring at pH 5.3. The IEP shifts down on calcining the powder and also when anionic polyelectrolytes are added. Rheological studies have been made on suspensions prepared to a solids loading of 27 vol.% (72 wt.%). Optimum dispersing condit...

  3. Experiences with Cascara-Salax preparating children for barium enema

    International Nuclear Information System (INIS)

    30 children prepared for barium enema using Cascara-Salax are reported on. The results are: 1. A satisfactory preparation is possible in out-patient children older than ten years. 2. For children aged 6 to 10 years only the half dose early in the afternoon before the X-ray examination is necessary. 3. In most cases the colon is completely clear, if not, the X-ray study is generally not influenced by rests of stool. 4. It should be considered that other - and often unreliable - cleaning manoevers aren't necessary, the Cascara-Salax - method ist time - saving and side-effects are not of value. (orig.)

  4. Bis(chlorido)(dimethyl­sulfoxide-κO)barium(II)

    OpenAIRE

    Gschwind, Fabienne; Jansen, Martin

    2012-01-01

    The title compound, [BaCl2(C2H6SO)], forms a Ba6Cl9 cluster in which the BaCl2 units are connected via dimethyl­sulfoxide (DMSO) and chloride bridges. The central Cl atom of the Ba6Cl9 cluster is located on a threefold inversion axis and is coordinated octa­hedrally to six barium cations. In the crystal, the clusters are arranged in rows, which are inter­connected by the DMSO mol­ecules, forming a three-dimensional network.

  5. Magnetic and structural investigations on barium hexaferrite ferrofluids

    Science.gov (United States)

    Müller, R.; Hiergeist, R.; Gawalek, W.; Hoell, A.; Wiedenmann, A.

    2002-11-01

    Barium hexaferrite BaFe 12-2 xTi xCo xO 19 ferrofluids have been prepared using oleic acid as surfactant and Isopar M ® or dodecane as carrier liquid. The ferrite particles were prepared by glass crystallization. Hysteresis parameters, the initial susceptibility versus temperature and the magnetic particle size were obtained by VSM. Ferrofluids with a partly deuterated carrier liquid were investigated by small angle neutron scattering (SANS). SANS curves lead to a bimodal size distribution consisting of single magnetic particles with an organic shell and aggregated particles with an incomplete organic layer.

  6. Radium and barium in the Amazon River system

    International Nuclear Information System (INIS)

    Data for 226Ra and 228Ra in the Amazon River system show that the activity of each radium isotope is strongly correlated with barium concentrations. Two trends are apparent, one for rivers which drain shield areas and another for all other rivers. These data suggest that there has been extensive fractionation of U, Th, and Ba during weathering in the Amazon basin. The 226Ra data fit a flux model for the major ions indicating that 226Ra behaves conservatively along the main channel of the Amazon River

  7. A comparison study between diagnostic value of sonography and Barium swallow in gasteroesophageal reflux in pediatrics

    Directory of Open Access Journals (Sweden)

    Fallahi G

    2001-10-01

    Full Text Available One of the common problems in children and specially in infants is gasteroesophageal reflux (G.E.R. Present study was performed to compare diagnostic value of lower esophageal sonography with barium swallow. This study was conducted on 50 patients 1 month to 15 years age in center of pediatric clinic of Tehran, during the years 1999-2000. Patients suspected to have G.E.R studied with lower esophageal sonography and barium swallow and at the end, their results were compared with esophageal PH monitoring as a standard test. In this study sensevity of sonography was 90 percent against 50 percent for barium swallow but specifity of two test was the same 35 percent. We can concluded that sonography is a non invasive, low cost, with less side effects than barium swallow. We recommend sonography in place of barium swallow in diagnosis of G.E.R.

  8. A Comparison between the Diagnostic Value of Sonography vs. Barium Swallow In Gastroesdophageal Reflux in Children

    Directory of Open Access Journals (Sweden)

    F. Zandie

    2003-06-01

    Full Text Available Background: One of the common problems in children, especially infants, is gastroesophageal reflux (GER. Objectives:This study was performed to compare the diagnostic value of lower esophageal sonography with that of barium swallow. Patients and method: Our trial was a triple-blind, performed on 50 patients of 1 month to 15 years of age. The patients suspicious of having GER were evaluated by sonography and barium swallow. Esophageal pH monitoring was the standard test, and both the ultrasound and barium swallow were compared to it. Results: The results showed that sonography was 90% sensitive, vs. 50% for barium swallow. Both tests had the same specificity equal to 35%. Conclusion: We concluded that sonography was a better test than barium swallows, for evaluation of suspected patients with GER, and screening of the infants.

  9. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  10. Segmentation of ribs in digital chest radiographs

    Science.gov (United States)

    Cong, Lin; Guo, Wei; Li, Qiang

    2016-03-01

    Ribs and clavicles in posterior-anterior (PA) digital chest radiographs often overlap with lung abnormalities such as nodules, and cause missing of these abnormalities, it is therefore necessary to remove or reduce the ribs in chest radiographs. The purpose of this study was to develop a fully automated algorithm to segment ribs within lung area in digital radiography (DR) for removal of the ribs. The rib segmentation algorithm consists of three steps. Firstly, a radiograph was pre-processed for contrast adjustment and noise removal; second, generalized Hough transform was employed to localize the lower boundary of the ribs. In the third step, a novel bilateral dynamic programming algorithm was used to accurately segment the upper and lower boundaries of ribs simultaneously. The width of the ribs and the smoothness of the rib boundaries were incorporated in the cost function of the bilateral dynamic programming for obtaining consistent results for the upper and lower boundaries. Our database consisted of 93 DR images, including, respectively, 23 and 70 images acquired with a DR system from Shanghai United-Imaging Healthcare Co. and from GE Healthcare Co. The rib localization algorithm achieved a sensitivity of 98.2% with 0.1 false positives per image. The accuracy of the detected ribs was further evaluated subjectively in 3 levels: "1", good; "2", acceptable; "3", poor. The percentages of good, acceptable, and poor segmentation results were 91.1%, 7.2%, and 1.7%, respectively. Our algorithm can obtain good segmentation results for ribs in chest radiography and would be useful for rib reduction in our future study.

  11. Retention of anatomy knowledge by student radiographers

    International Nuclear Information System (INIS)

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  12. On being dyslexic: Student radiographers' perspectives

    International Nuclear Information System (INIS)

    The purpose of this paper was to provide an insight into life as a dyslexic student radiographer, identify barriers and risks in clinical training, and develop recommendations for the support of students with dyslexia. The paucity of research into dyslexia within the radiography profession is worrying, with attention focused only on the support provided by Higher Education Institutions (HEI) or inferences drawn from the experiences of other healthcare students. The impact and significance of dyslexia for student radiographers in clinical practice has never been investigated. Results: On a self-reporting scale of clinical tasks there was little or no difference between dyslexic students and non-dyslexics. Some minor traits commonly associated with dyslexics were also reported by students with no learning disabilities and an inclusion support plan for all students was advocated. In-depth interviews of 10 student radiographers revealed six distinct themes of visualising the disability, self-protection, strengths and talents, time, the badge of disability and adjustments and support. Like other healthcare students, some radiography students reported significant difficulties and prejudices and very little structured support in the clinical environment. Despite the Special Educational Needs and Disability Act being in place for several years, the support in clinical departments fell significantly short of that provided in the universities. The dyslexic students took extra responsibility for their own learning and some had developed complex coping strategies to overcome any difficulties. Conclusion: Several inclusive recommendations were developed as a result of this study that could be used to support all students on clinical placement.

  13. Retention of anatomy knowledge by student radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Hall, A. Susanne [Division of Radiography, School of Health and Social Care, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA (United Kingdom)], E-mail: a.s.hall@gcal.ac.uk; Durward, Brian R. [Educational Development, NHS Education for Scotland, Floor 5, Thistle House, 91 Haymarket Terrace, Edinburgh EH12 5HD (United Kingdom)

    2009-08-15

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  14. Anion and cation diffusion in barium titanate and strontium titanate; Anionen- und Kationendiffusion in Barium- und Strontiumtitanat

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, Markus Franz

    2012-12-19

    Perovskite oxides show various interesting properties providing several technical applications. In many cases the defect chemistry is the key to understand and influence the material's properties. In this work the defect chemistry of barium titanate and strontium titanate is analysed by anion and cation diffusion experiments and subsequent time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reoxidation equation for barium titanate used in multi-layer ceramic capacitors (MLCCs) is found out by a combination of different isotope exchange experiments and the analysis of the resulting tracer diffusion profiles. It is shown that the incorporation of oxygen from water vapour is faster by orders of magnitude than from molecular oxygen. Chemical analysis shows the samples contain various dopants leading to a complex defect chemistry. Dysprosium is the most important dopant, acting partially as a donor and partially as an acceptor in this effectively acceptor-doped material. TEM and EELS analysis show the inhomogeneous distribution of Dy in a core-shell microstructure. The oxygen partial pressure and temperature dependence of the oxygen tracer diffusion coefficients is analysed and explained by the complex defect chemistry of Dy-doped barium titanate. Additional fast diffusion profiles are attributed to fast diffusion along grain boundaries. In addition to the barium titanate ceramics from an important technical application, oxygen diffusion in cubic, nominally undoped BaTiO{sub 3} single crystals has been studied by means of {sup 18}O{sub 2}/{sup 16}O{sub 2} isotope exchange annealing and subsequent determination of the isotope profiles in the solid by ToF-SIMS. It is shown that a correct description of the diffusion profiles requires the analysis of the diffusion through the surface space-charge into the material's bulk. Surface exchange coefficients, space-charge potentials and bulk diffusion coefficients are analysed as a function of oxygen partial

  15. Radiographic analysis of temporomandibular joint arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1984-11-15

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  16. Radiographic analysis of temporomandibular joint arthrosis

    International Nuclear Information System (INIS)

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  17. Commitment of the radiographer - does it matter to the patient?

    International Nuclear Information System (INIS)

    Full text: Radiographers are responsible for providing safe and accurate imaging examinations in a wide range of clinical environments, using a variety of imaging modalities and techniques so that appropriate management and treatment of patients and clients can proceed. The purpose of this presentation is to discuss: the responsibilities of radiographer in the clinical radiology department; their professional judgment to decide how to achieve a diagnostic outcome; the relationship patient/radiographer; the impact of the radiographer on patient care. Patient care and advocacy has always been an integral part of the radiography profession. The radiographer should respect the patient at all the times, be genuine in nature and empathies with the patient‘s condition. Good listening and observational skills are also very important components. The radiographers are personally accountable for their work and professional conduct

  18. Tungsten and Barium Transport in the Internal Plasma of Hollow Cathodes

    Science.gov (United States)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2008-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the flow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushedback to the emitter surface by the electric field and drag from the xenon ion flow. Thisbarium ion flux is sufficient to maintain a barium surface coverage at the downstream endgreater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length,so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollowcathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  19. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  20. Preliminary study of radiographic technique x doses in patients submitted to standard radiographic exams

    International Nuclear Information System (INIS)

    An evaluation of entrance skin dose in patients submitted to actual examinations, arising from present radiographic procedure in 10 rooms in Curitiba, PR, Brazil between December/95 and April/96 is presented. The basis for extensive studies, on local or regional level, is outlined

  1. Xeroradiographic and radiographic anatomy of the channel catfish, Ictalurus punctatus

    International Nuclear Information System (INIS)

    The purpose of this study was to provide an anatomic reference for the channel catfish (Ictalurus punctatus) using xeroradiography† and conventional radiography. The entire body of three adult fish was radiographed using standard xeroradiographic and conventional radiographic techniques. Two xeroradiographs and their corresponding conventional radiographs were selected, and the xeroradiographs labeled to illustrate the normal skeletal and soft-tissue anatomy of the channel catfish

  2. Susuk - Black Magic Exposed “White” by Dental Radiographs

    OpenAIRE

    F, Arishiya Thapasum; Mohammed, Faraz

    2014-01-01

    Susuk or charm needles are a facial cum body art widely practiced among women of Malaysia, Brunei, Singapore, Thailand and Indonesia. These are small, needle-shaped metallic talismans inserted subcutaneously in different parts of the body. The concealed art of susuk was “exposed” by routine radiographic examination in the oral and maxillofacial region. This paper reports two such cases of unusual incidental radiographic finding in dental radiographs which were taken on a routine basis as part...

  3. A Role of Dental Radiograph in Human Forensic Identification

    OpenAIRE

    Dipali Rindhe; Prof. A.N. Shaikh

    2013-01-01

    Dental based human identification is commonly used in forensic. Dentistry can contribute for theidentification of human remains after any disasters or crimes in assistance to other medical specialties. Thealgorithm can be developed by comparing post mortem and ante mortem dental radiographs. This work aimsto introduce radiographic images. In this paper, a contour and skeleton-based shape extraction as well asmatching algorithm for dental radiograph is proposed. An active contour model with se...

  4. Simulation of neutron radiograph images at the Neutron Radiography Reactor

    International Nuclear Information System (INIS)

    Highlights: ► The project developed a method to simulate neutron radiograph images. ► A characteristic curve relation activation foil activity to film optical density. ► The simulation uses the characteristic curve to predict radiographic images. ► Radiographs of a polyethylene step block validate the methodology. - Abstract: The ability to accurately simulate potential radiographic images produced by a radiographic facility can improve the facility’s ability to design experiments and evaluate images. The image simulation methods detailed in this paper predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in a Monte Carlo beamline model. The image simulation method utilizes a characteristic curve relating foil activity to optical density for the film and foil combination in use at the Neutron Radiography Reactor. The simulation validation compared a radiograph of a polyethylene step block to a simulated radiograph of the same step block. The simulation accurately predicts the optical density in each region of a radiograph of the step block. The simulated radiograph predicts the average optical density of the actual radiograph more accurately for the thinner steps, resulting in step averaged optical density differences between the actual and simulated images of −11.6% for the thinnest step versus a difference of −34.7% for the thickest step, possibly due to the greater accuracy of the higher optical density region of the characteristic curve. Applying the scanner calibration curve to the calculated optical density values decreases the difference between the actual radiograph pixel values and the simulated pixel values for each step except the thinnest step. The step averaged differences between the corrected and actual images increase from −11.6% to −17.0% for the thinnest step and decrease from −34.7% to +7.7% for the thickest step after the

  5. Ruthenium and hafnium abundances in giant and dwarf barium stars

    CERN Document Server

    Allen, D M

    2007-01-01

    We present abundances for Ru and Hf, compare them to abundances of other heavy elements, and discuss the problems found in determining Ru and Hf abundances with laboratory gf-values in the spectra of barium stars. We determined Ru and Hf abundances in a sample of giant and dwarf barium stars, by the spectral synthesis of two RuI (4080.574A and 4757.856A) and two HfII (4080.437A and 4093.155A) transitions. The stellar spectra were observed with FEROS/ESO, and the stellar atmospheric parameters lie in the range 4300 < Teff/K < 6500, -1.2 < [Fe/H] <= 0 and 1.4 <= log g < 4.6. The HfII 4080A and the RuI 4758A observed transitions result in a unreasonably high solar abundance, given certain known uncertainties, when fitted with laboratory gf-values. For these two transitions we determined empirical gf-values by fitting the observed line profiles of the spectra of the Sun and Arcturus. For the sample stars, this procedure resulted in a good agreement of Ru and Hf abundances given by the two availa...

  6. Study of barium bismuth titanate prepared by mechanochemical synthesis

    Directory of Open Access Journals (Sweden)

    Lazarević Z.Ž.

    2009-01-01

    Full Text Available Barium-bismuth titanate, BaBi4Ti4O15 (BBT, a member of Aurivillius bismuth-based layer-structure perovskites, was prepared from stoichiometric amounts of barium titanate and bismuth titanate obtained via mechanochemical synthesis. Mechanochemical synthesis was performed in air atmosphere in a planetary ball mill. The reaction mechanism of BaBi4Ti4O15 and the preparation and characteristics of BBT ceramic powders were studied using XRD, Raman spectroscopy, particle analysis and SEM. The Bi-layered perovskite structure of BaBi4Ti4O15 ceramic forms at 1100 °C for 4 h without a pre-calcination step. The microstructure of BaBi4Ti4O15 exhibits plate-like grains typical for the Bi-layered structured material and spherical and polygonal grains. The Ba2+ addition leads to changes in the microstructure development, particularly in the change of the average grain size.

  7. Materials Synthesis Of Barium Hexa ferrite Used Local Natural Resources

    International Nuclear Information System (INIS)

    The magnetic materials of barium hexa ferrites, Ba O.6Fe2O3 successfully synthesized by powder metallurgy method used local natural resources from materials waste of steel fabrication (HSM, CRM), waste of polymer fabrication (LK) as well as iron sands (PBA). These waste as well as iron sands were the main resources of iron oxide, Fe2O3. The barium oxide used in this experiments are from BaCO3 product of Merck, and BaCO4 which is commercially available in the market as barite. Phase identification by x-ray diffraction technique show the synthesized magnetic materials are agreed with the available commercial product, (SUMI). The energy product maximum (BH)max measured by vibrating sample magnetometer (VSM) for the samples used HSM-, CRM- and BaCO3 as basic materials are 1.141 MGOe and 1.136 MGOe while SUMI is 1.142 MGOe. However for the samples made from LK-, PBA- used of BaCO3 or CRM- with barite, the energy product maximum (BH)max are relatively lower than commercial product

  8. Brillouin function characteristics for La-Co substituted barium hexaferrites

    International Nuclear Information System (INIS)

    La-Co substituted barium hexaferrites with the chemical formula of Ba1−xLaxFe12−xCoxO19 (x = 0.0, 0.1, 0.3, and 0.5), prepared by a conventional ceramic method, were systematically investigated by Raman spectra, X-ray photoelectron spectroscopy, Rietveld refinement of X-ray diffraction patterns, and vibrating sample magnetometer. The result manifests that all the compounds are crystallized in magnetoplumbite hexagonal structure. Trivalent cobalt ions prevailingly occupy the 2a, 4f1, and 12k sites. According to Néel model of collinear-spin ferrimagnetism, the molecular-field coefficients ωbf2, ωkf1, ωaf1, ωkf2, and ωbk of La-Co substituted barium hexaferrites have been calculated using the nonlinear fitting method, and the magnetic moment of five sublattices (2a, 2b, 4f1, 4f2, and 12k) versus temperature T has been also investigated. The fitting results are coincided well with the experimental data. Moreover, with the increase of La-Co substitution amount x, the molecular-field coefficients ωbf2 and ωaf1 decrease constantly, while the molecular-field coefficients ωkf1, ωkf2, and ωbk show a slight change

  9. Thermal expansion behaviour of barium and strontium zirconium phosphates

    Indian Academy of Sciences (India)

    P Srikari Tantri; K Geetha; A M Umarji; Sheela K Ramasesha

    2000-12-01

    Ba1.5–SrZr4P5SiO24 compounds with = 0, 0.25, 0.5, 0.75, 1.0, 1.25 and 1.5, belonging to the low thermal expansion NZP family were synthesized by the solid state reaction method. The XRD pattern could be completely indexed with respect to R$\\bar{3}$ space group indicating the ordering of vacancy at the divalent cation octahedral sites. The microstructure and bulk thermal expansion coefficient from room temperature to 800°C of the sintered samples have been studied. All the samples show very low coefficient of thermal expansion (CTE), with = 0 samples showing negative expansion. A small substitution of strontium in the pure barium compound changes the sign of CTE. Similarly, = 1.5 sample (pure strontium) shows a positive CTE and a small substitution of barium changes its sign. = 1.0 and 1.25 samples have almost constant CTE over the entire temperature range. The low thermal expansion of these samples can be attributed to the ordering of the ions in the crystal structure of these materials.

  10. Microstructure of composite material with powders of barium ferrite

    Directory of Open Access Journals (Sweden)

    R. Nowosielski

    2006-04-01

    Full Text Available Purpose: The aim of the present work is the microstructure characterization of commercial powder BaFe12O19 (as-prepared and composite material with BaFe12O19 powders and polymer matrix, using XRD (X-Ray Diffraction and SEM (Scanning Electron Microscopy methods.Design/methodology/approach: The morphology of barium ferrite powders and a fracture surface of the examined composite material was realized by using the scanning electron microscope. The methods of X-ray diffraction were used for the qualitative phase analysis. The parameters of diffraction line profiles were determined by PRO-FIT Toraya procedure.Findings: The X-ray diffraction analysis permitted on identification the BaFe12O19 and Fe2O3 phases in an examined material. Basing on Toraya method is determination of: lattice parameters, crystallite size (D and the lattice distortion (. Distribution of powders of barium ferrite in polymer matrix is irregular and powder particles have irregular shapes and dimensions.Research limitations/implications: For future research the X-ray analysis should be performed by the Rietveld method, which allows to characterization the microstructure of tested material and verification of its qualitative phase composition.Originality/value: The applied Toraya method of structure analysis appeared to be very useful in the microstructure analysis.

  11. Redox processes in highly yttrium-doped barium titanate

    International Nuclear Information System (INIS)

    The changes of microstructure occurring during oxidation of the reduced form of yttrium-doped barium titanate (Ba1-xYx?Ti1-x4+Tix3+O3) have been studied. Samples were sintered under reduction conditions at PO2=10-4Pa and oxidized by annealing at high temperatures (1150 and 1350 deg. C) in air. Depending on yttrium concentration, the oxidation of the reduced form of the yttrium-doped BaTiO3 caused precipitation of the phase Ba6Ti17O40 or the phases Ba6Ti17O40 and Y2Ti2O7. The precipitates had well-defined orientational relationships with the perovskite matrix. Oxidation of the reduced form of doped barium titanate results in formation of the phase Ba1-xYx?Ti1-x/44+(VTi-bar )x/4O3 responsible for increase in the resistance of outer grain layers, which lie between grain boundaries and grain

  12. The Kerr nonlinearity of the beta-barium borate crystal

    DEFF Research Database (Denmark)

    Bache, Morten; Guo, Hairun; Zhou, Binbin;

    2013-01-01

    A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond experime......A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond...... experiments BBO is popular because of low dispersion and a high damage threshold. The main attractive property of ultrafast cascading is that the induced cascading nonlinearity nI 2, casc can be negative, i.e. generate a self-defocusing Kerr-like nonlinearity. However, the material Kerr nonlinearity nI 2......, Kerr is self-focusing and competes with the cascading nonlinearity. Therefore, precise knowledge of its strength is crucial. We perform an experiment measuring the main c ü tensor component, and together with literature experimental data [1], we propose a cu value composed of 14 different data points...

  13. Radiographic caries diagnosis and restorative treatment decision making

    International Nuclear Information System (INIS)

    This thesis is concerned with a single diagnostic technique: the bitewing radiograph, and the way it is used by dentists to decide on patient treatment need for interproximal caries. The variation in caries diagnosis and treatment decisions using bitewing radiographs is described and the radiographic criteria of choice for minimizing over and undertreatment according to a norm are investigated. Three possible diagnostic strategies in interproximal caries diagnosis using a decision analysis approach are described and evaluated, and the effect of the reported diagnostic behaviour and knowledge of practicing Dutch dentists in their use of bitewing radiographs for the diagnosis and treatment of interproximal caries is described and analyzed. (Auth.)

  14. Radiographic evaluation of dentigerous cyst with cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Chan; Lee, Wan; Lee, Byung Do [School of Dentisity, Wonkwang University, Iksan (Korea, Republic of)

    2010-09-15

    The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

  15. Computer Analysis Of ILO Standard Chest Radiographs Of Pneumoconiosis

    Science.gov (United States)

    Li, C. C.; Shu, David B. C.; Tai, H. T.; Hou, W.; Kunkle, G. A.; Wang, Y.; Hoy, R. J.

    1982-11-01

    This paper presents study of computer analysis of the 1980 ILO standard chest radiographs of pneumoconiosis. Algorithms developed for detection of individual small rounded and irregular opacities have been experimented and evaluated on these standard radiographs. The density, shape, and size distribution of the detected objects in the lung field, in spite of false positives, can be used as indicators for the beginning of pneumoconiosis. This approach is potentially useful in computer-assisted screening and early detection process where the annual chest radiograph of each worker is compared with his (her) own normal radiograph obtained previously.

  16. Liquid-Phase Processing of Barium Titanate Thin Films

    Science.gov (United States)

    Harris, David Thomas

    Processing of thin films introduces strict limits on the thermal budget due to substrate stability and thermal expansion mismatch stresses. Barium titanate serves as a model system for the difficulty in producing high quality thin films because of sensitivity to stress, scale, and crystal quality. Thermal budget restriction leads to reduced crystal quality, density, and grain growth, depressing ferroelectric and nonlinear dielectric properties. Processing of barium titanate is typically performed at temperatures hundreds of degrees above compatibility with metalized substrates. In particular integration with silicon and other low thermal expansion substrates is desirable for reductions in costs and wider availability of technologies. In bulk metal and ceramic systems, sintering behavior has been encouraged by the addition of a liquid forming second phase, improving kinetics and promoting densification and grain growth at lower temperatures. This approach is also widespread in the multilayer ceramic capacitor industry. However only limited exploration of flux processing with refractory thin films has been performed despite offering improved dielectric properties for barium titanate films at lower temperatures. This dissertation explores physical vapor deposition of barium titanate thin films with addition of liquid forming fluxes. Flux systems studied include BaO-B2O3, Bi2O3-BaB2O 4, BaO-V2O5, CuO-BaO-B2O3, and BaO-B2O3 modified by Al, Si, V, and Li. Additions of BaO-B2O3 leads to densification and an increase in average grain size from 50 nm to over 300 nm after annealing at 900 °C. The ability to tune permittivity of the material improved from 20% to 70%. Development of high quality films enables engineering of ferroelectric phase stability using residual thermal expansion mismatch in polycrystalline films. The observed shifts to TC match thermodynamic calculations, expected strain from the thermal expansion coefficients, as well as x-ray diffract measurements

  17. Surface dose extrapolation measurements with radiographic film

    Energy Technology Data Exchange (ETDEWEB)

    Butson, Martin J [Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong, Hong Kong (China); Cheung Tsang [Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong, Hong Kong (China); Yu, Peter K N [Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong, Hong Kong (China); Currie, Michael [Illawarra Cancer Care Centre, Department of Medical Physics, Crown St, Wollongong, NSW 2500 (Australia)

    2004-07-07

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within {+-}3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% {+-} 2%, 29% {+-} 3% and 38% {+-} 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  18. Radiographic Evaluation of the Ankle Mortise

    Directory of Open Access Journals (Sweden)

    Hamid Mirbagheri

    2010-05-01

    Full Text Available The ankle joint is the most frequently injured joint in adults. Decisions on management are usually based on clinical examination and interpretation of the x-rays. Stability of the ankle mortise relies on the configuration of the osseous structures and the ligaments. A basic radiographic examination consists of a mortise-view and a lateral view. Some add the AP-view. The Mortise view is an AP-view with 15-25 degrees endorotation of the foot. "nThe view clearly demonstrates both lateral and medial joint spaces. On a true AP-view the talus overlaps a portion of the lateral malleolus obscuring the lateral aspect of the ankle joint. However, the AP-view will give you an extra view on both malleoli from a different angle. The lateral radiograph of the ankle should include the base of the fifth metatarsal because of the frequency of fractures at this side that clinically mimic a fracture of the ankle.

  19. Necrotizing fasciitis : plain radiographic and CT findings

    International Nuclear Information System (INIS)

    To evaluate the plain radiographic and CT findings of the necrotizing fasciitis. We retrospectively reviewed the radiologic findings of 4 cases with necrotizing fasciitis. Three cases were proven pathologically. We evaluated pattern and extent of the gas shadows in plain films. CT findings were analysed, with emphasis on : (a) gas pattern, (b) extent, (c) location and involved site, (d) associated focal abscess, and (e) swelling of the adjacent muscles. On plain radiographs, four cases showed streaky or mottled gas densities in the pelvis, three cases in the perineum, one case in the abdomen, and two cases in the thigh. On CT images, gas pattern was mottled and streaky appearance with swelling of the adjacent muscles. Gas shadows located in the extraperitoneal space in four cases, fascial layer in four cases, and subcutaneous layer in four cases. There were gas shadows in pelvic wall, perineum, abdominal wall, buttock, thigh, and scrotum. Focal low density lesion suggestive of focal abscess was not visualized. Plain radiography is useful for early diagnosis of the necrotizing fasciitis and CT is very useful for detection of precise location and extent of the disease. CT is also useful for differentiation of necrotizing fasciitis from focal abscess and cellulitis

  20. Necrotizing fasciitis : plain radiographic and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Dae; Park, Jeong Hee; Jeon, Hae Jeong; Lim, Jong Nam; Heo, Tae Haeng; Park, Dong Rib [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate the plain radiographic and CT findings of the necrotizing fasciitis. We retrospectively reviewed the radiologic findings of 4 cases with necrotizing fasciitis. Three cases were proven pathologically. We evaluated pattern and extent of the gas shadows in plain films. CT findings were analysed, with emphasis on : (a) gas pattern, (b) extent, (c) location and involved site, (d) associated focal abscess, and (e) swelling of the adjacent muscles. On plain radiographs, four cases showed streaky or mottled gas densities in the pelvis, three cases in the perineum, one case in the abdomen, and two cases in the thigh. On CT images, gas pattern was mottled and streaky appearance with swelling of the adjacent muscles. Gas shadows located in the extraperitoneal space in four cases, fascial layer in four cases, and subcutaneous layer in four cases. There were gas shadows in pelvic wall, perineum, abdominal wall, buttock, thigh, and scrotum. Focal low density lesion suggestive of focal abscess was not visualized. Plain radiography is useful for early diagnosis of the necrotizing fasciitis and CT is very useful for detection of precise location and extent of the disease. CT is also useful for differentiation of necrotizing fasciitis from focal abscess and cellulitis.

  1. MRI visualisation by digitally reconstructed radiographs

    Science.gov (United States)

    Serrurier, Antoine; Bönsch, Andrea; Lau, Robert; Deserno, Thomas M.

    2015-03-01

    Visualising volumetric medical images such as computed tomography and magnetic resonance imaging (MRI) on picture archiving and communication systems (PACS) clients is often achieved by image browsing in sagittal, coronal or axial views or three-dimensional (3D) rendering. This latter technique requires fine thresholding for MRI. On the other hand, computing virtual radiograph images, also referred to as digitally reconstructed radiographs (DRR), provides in a single two-dimensional (2D) image a complete overview of the 3D data. It appears therefore as a powerful alternative for MRI visualisation and preview in PACS. This study describes a method to compute DRR from T1-weighted MRI. After segmentation of the background, a histogram distribution analysis is performed and each foreground MRI voxel is labeled as one of three tissues: cortical bone, also known as principal absorber of the X-rays, muscle and fat. An intensity level is attributed to each voxel according to the Hounsfield scale, linearly related to the X-ray attenuation coefficient. Each DRR pixel is computed as the accumulation of the new intensities of the MRI dataset along the corresponding X-ray. The method has been tested on 16 T1-weighted MRI sets. Anterior-posterior and lateral DRR have been computed with reasonable qualities and avoiding any manual tissue segmentations. This proof-of-concept holds for research application for use in clinical PACS.

  2. Subperiosteal osteoid osteoma: radiographic and pathologic manifestations

    International Nuclear Information System (INIS)

    Objective.To demonstrate the radiologic and pathologic manifestations of osteoid osteoma arising beneath the periosteum, on the surface of the bone. Design. One hundred and sixty osteoid osteomas were seen over a 30-year period. The radiologic, pathologic and operative findings of those that were subperiosteal were reviewed. Patients. Eleven patients with subperiosteal osteoid osteoma were reviewed. The patients ranged in age from 13 to 36 years with a mean of 24 years. Eight were male and three were female. Results and conclusion. Eleven subperiosteal lesions were studied. The reactive periostitis of four lesions was atypical and misleading. Four lesions had features similar to the more common intracortical variety. Three lesions occurring within the joint like other intra-articular lesions were barely seen on plain radiographs. Bone scan and CT scan were virtually diagnostic. The histopathology of these lesions was also atypical though not misleading. In conclusion, subperiosteal osteoid osteoma is a rare lesion with atypical radiographic and histopathologic features. The unusual reactive periostitis seen in several extra-articular cases may suggest other diagnoses. (orig.). With 4 figs., 2 tabs

  3. Subperiosteal osteoid osteoma: radiographic and pathologic manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Shankman, S. [Department of Radiology, Hospital for Joint Diseases/OI, 301 East 17th Street, New York, NY 10003 (United States); Desai, P. [Department of Pathology, Hospital for Joint Diseases/OI, 301 East 17th Street, New York, NY 10003 (United States); Beltran, J. [Department of Radiology, Hospital for Joint Diseases/OI, 301 East 17th Street, New York, NY 10003 (United States)

    1997-08-01

    Objective.To demonstrate the radiologic and pathologic manifestations of osteoid osteoma arising beneath the periosteum, on the surface of the bone. Design. One hundred and sixty osteoid osteomas were seen over a 30-year period. The radiologic, pathologic and operative findings of those that were subperiosteal were reviewed. Patients. Eleven patients with subperiosteal osteoid osteoma were reviewed. The patients ranged in age from 13 to 36 years with a mean of 24 years. Eight were male and three were female. Results and conclusion. Eleven subperiosteal lesions were studied. The reactive periostitis of four lesions was atypical and misleading. Four lesions had features similar to the more common intracortical variety. Three lesions occurring within the joint like other intra-articular lesions were barely seen on plain radiographs. Bone scan and CT scan were virtually diagnostic. The histopathology of these lesions was also atypical though not misleading. In conclusion, subperiosteal osteoid osteoma is a rare lesion with atypical radiographic and histopathologic features. The unusual reactive periostitis seen in several extra-articular cases may suggest other diagnoses. (orig.). With 4 figs., 2 tabs.

  4. A radiographic study of the condylar hyperlasia

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Soo; Kim, Young Jin; Choi, Eui Hwan; Kim, Jae Duk [Chosun University, Kwangju (Korea, Republic of)

    1995-08-15

    Condylar hyperplasia is a self-limiting condition characterized by a slowly progressing, enlargement of the mandible that results in facial asymmetry and a cross bite maloccusion. The facial asymmetry, open bite or cross bite, and radio graphic evidence of an enlarged condyle confirm the diagnosis of condylar hyperplasia. The etiology of the condition is unknown. This condition usually first becomes apparent during the second decade of life, when one condyle continues to grow while the other is no longer active. Radiographically, the condyle may appear enlarged or the neck of the condyle may be elongated or both may occur, sometimes, however, no raiographically demonstrable condylar abnormality will be noted. Surgical correction with subcondylar osteotomy is the treatment choice. We have observed two cases of condylar hyperplsia occurred in the left mandibular condyle of 24-year-old and 35-year- old women. We obtained that two cases were shown the followed results; 1. Clinically, both cases was unilaterally developed on C/C area, with temporomandibular disorders and pain, facial asymmetry and malcclusion. 2. Radiographically, hyperplastic mass confined to the condyle. 3. Histopathologically, these cases shown increased hypertrophic region in parts, and lamellated bone wit h irregular trabeculae.

  5. Occupational stress and its predictors in radiographers

    International Nuclear Information System (INIS)

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it

  6. Sensitometric responses of selected medical radiographic films.

    Science.gov (United States)

    Kofler, J M; Gray, J E

    1991-12-01

    Radiographic films produce different densities and contrast when processor changes occur, and the magnitude and rate of change vary with film type. The ability to detect and interpret the clinical importance of film density changes may depend on the method of sensitometry used. The characteristics of several medical radiographic films and various sensitometers were examined under three sensitometric variations and five processing variations. Of all variations used, only exposure with a single-versus a double-sided sensitometer caused a film type to have a marked different response. The results indicate that mismatching the sensitometer spectral output with the spectral sensitivity of the film in most cases does not affect the density changes of the film. The fact that a few films may be sensitive to differences in spectral content of the exposing light and dual- versus single-sided exposure and that only a limited number of film types were tested, however, leads to the prudent conclusion that the exposure conditions for quality control purposes should match clinical exposure conditions as closely as possible. PMID:1947114

  7. Detection of hip dysplasia using standard position radiographs compared to stress positioning radiographs in 43 assistance trained dogs

    International Nuclear Information System (INIS)

    Radiographic detection of hip dysplasia was performed on 43 assistance-trained dogs using both standard positioning (ventro-dorsal view of hips in full extension) and stress positioning. The standard radiographs were analysed and classified using the FCI grid. For stress positioning radiographs, a distraction index was calculated to evaluate hip joint laxity. This study shows that joint laxity increases in parallel with the severity of the classification on the FCI grid

  8. Preparation and properties of yttria doped tetragonal zirconia polycrystal/Sr-doped barium hexaferrite ceramic composites

    International Nuclear Information System (INIS)

    Highlights: • The 3Y-TZP/Sr-doped barium ferrite composites were prepared. • The saturation magnetization was improved by 15% with Sr-doping. • The dispersion coefficient p could reflect the microscopic lattice variation. • The composite with x = 0.5 had the maximum fracture toughness of 8.3 MPa m1/2. - Abstract: The effects of substitution of Ba2+ by Sr2+ on the magnetic property of barium ferrite and addition barium ferrite secondary phase to the 3 mol% yttria-doped tetragonal zirconia polycrystal (3Y-TZP) matrix on the mechanical property of composites were investigated. The Sr-doped barium ferrite (Ba1−xSrxFe12O19, x = 0, 0.25, 0.50 and 0.75) was synthesized by solid-state reaction in advance. Then 3Y-TZP/20 wt% Sr-doped barium ferrite composites were prepared by means of conventional ceramic method. It was found that a moderate amount of Sr added to barium ferrite could boost the saturation magnetization by 15% compared with the composites without Sr-doping. Besides, the composite with x = 0.50 possessed the best mechanical properties, such as 11.5 GPa for Vickers hardness and 8.3 MPa m1/2 for fracture toughness, respectively. It was demonstrated that magnetic and mechanical properties of the composites could be harmonized by the incorporation of barium ferrite secondary phase

  9. Bio-based barium alginate film: Preparation, flame retardancy and thermal degradation behavior.

    Science.gov (United States)

    Liu, Yun; Zhang, Chuan-Jie; Zhao, Jin-Chao; Guo, Yi; Zhu, Ping; Wang, De-Yi

    2016-03-30

    A bio-based barium alginate film was prepared via a facile ionic exchange and casting approach. Its flammability, thermal degradation and pyrolysis behaviors, thermal degradation mechanism were studied systemically by limiting oxygen index (LOI), vertical burning (UL-94), microscale combustion calorimetry (MCC), thermogravimetric analysis (TGA) coupled with Fourier transform infrared analysis (FTIR) and pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). It showed that barium alginate film had much higher LOI value (52.0%) than that of sodium alginate film (24.5%). Moreover, barium alginate film passed the UL-94 V-0 rating, while the sodium alginate film showed no classification. Importantly, peak of heat release rate (PHRR) of barium alginate film in MCC test was much lower than that of sodium alginate film, suggested that introduction of barium ion into alginate film significantly decreased release of combustible gases. TG-FTIR and Py-GC-MS results indicated that barium alginate produced much less flammable products than that of sodium alginate in whole thermal degradation procedure. Finally, a possible degradation mechanism of barium alginate had been proposed. PMID:26794953

  10. Barium titanate core – gold shell nanoparticles for hyperthermia treatments

    Directory of Open Access Journals (Sweden)

    FarrokhTakin E

    2013-06-01

    Full Text Available Elmira FarrokhTakin,1,2 Gianni Ciofani,1 Gian Luigi Puleo,1 Giuseppe de Vito,3,4 Carlo Filippeschi,1 Barbara Mazzolai,1 Vincenzo Piazza,3 Virgilio Mattoli1 1Center for Micro-BioRobotics @SSSA, Fondazione Istituto Italiano di Tecnologia, Pontedera, Pisa, Italy; 2The Biorobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Pisa, Italy; 3Center for Nanotechnology Innovation @NEST, Fondazione Istituto Italiano di Tecnologia, Pisa, Italy; 4NEST, Scuola Normale Superiore, Pisa, Italy Abstract: The development of new tools and devices to aid in treating cancer is a hot topic in biomedical research. The practice of using heat (hyperthermia to treat cancerous lesions has a long history dating back to ancient Greece. With deeper knowledge of the factors that cause cancer and the transmissive window of cells and tissues in the near-infrared region of the electromagnetic spectrum, hyperthermia applications have been able to incorporate the use of lasers. Photothermal therapy has been introduced as a selective and noninvasive treatment for cancer, in which exogenous photothermal agents are exploited to achieve the selective destruction of cancer cells. In this manuscript, we propose applications of barium titanate core–gold shell nanoparticles for hyperthermia treatment against cancer cells. We explored the effect of increasing concentrations of these nanoshells (0–100 µg/mL on human neuroblastoma SH-SY5Y cells, testing the internalization and intrinsic toxicity and validating the hyperthermic functionality of the particles through near infrared (NIR laser-induced thermoablation experiments. No significant changes were observed in cell viability up to nanoparticle concentrations of 50 µg/mL. Experiments upon stimulation with an NIR laser revealed the ability of the nanoshells to destroy human neuroblastoma cells. On the basis of these findings, barium titanate core–gold shell nanoparticles resulted in being suitable for hyperthermia treatment

  11. Wideband and enhanced microwave absorption performance of doped barium ferrite

    International Nuclear Information System (INIS)

    To achieve stronger microwave attenuation and larger bandwidth in electromagnetic absorber, the nickel ions (Ni2+) and manganese ions (Mn2+) were employed to partially replace the cobalt ions (Co2+) in BaCoTiFe10O19, and the doped barium hexaferrite (Ba(MnNi)0.2Co0.6TiFe10O19 and Ba(MnNi)0.25Co0.5TiFe10O19) powders were synthesized via the sol–gel combustion method. Subsequently, the microwave absorbing composites were prepared by mixing the ferrite powders with the paraffin. The X-ray diffraction (XRD) patterns of the doped ferrites confirmed the formation of the M-type barium ferrite, and no other types of barium ferrite could be found. Based on the electromagnetic parameters measured by the vector net-analyzer, it was found that the composite (Ba(MnNi)0.2Co0.6TiFe10O19) possessed a minimum reflection loss of −52.8 dB at 13.4 GHz with a matching thickness of 1.8 mm and the bandwidth below −15 dB was 5.8 GHz. Moreover, the maximum attenuation of Ba(MnNi)0.25Co0.5TiFe10O19 could reach −69 dB when its thickness was 1.8 mm, and also the bandwidth less than −20 dB was ranging from 13.2 GHz to 18 GHz. Thus, Ba(MnNi)0.2Co0.6TiFe10O19 and Ba(MnNi)0.25Co0.5TiFe10O19 could be the good microwave absorbers, which have great potentials to be applied in the high frequency fields of the microwave absorbing materials. - Highlights: • The Co was first time substituted by Mn–Ni in ferrites. • The substituted ferrites had good microwave absorption. • The doped ferrites had broad bandwidth and low reflection loss

  12. Wideband and enhanced microwave absorption performance of doped barium ferrite

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Pingyuan; Xiong, Kun [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, School of Materials Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China); Ju, Kui [Guizhou Institute of Metallurgy and Chemical Engineering, Guiyang 550002 (China); Li, Shengnan [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, School of Materials Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China); Xu, Guangliang, E-mail: xuguangliang@swust.edu.cn [State Key Laboratory Cultivation Base for Nonmetal Composites and Functional Materials, School of Materials Science and Engineering, Southwest University of Science and Technology, Mianyang 621010 (China)

    2015-07-01

    To achieve stronger microwave attenuation and larger bandwidth in electromagnetic absorber, the nickel ions (Ni{sup 2+}) and manganese ions (Mn{sup 2+}) were employed to partially replace the cobalt ions (Co{sup 2+}) in BaCoTiFe{sub 10}O{sub 19}, and the doped barium hexaferrite (Ba(MnNi){sub 0.2}Co{sub 0.6}TiFe{sub 10}O{sub 19} and Ba(MnNi){sub 0.25}Co{sub 0.5}TiFe{sub 10}O{sub 19}) powders were synthesized via the sol–gel combustion method. Subsequently, the microwave absorbing composites were prepared by mixing the ferrite powders with the paraffin. The X-ray diffraction (XRD) patterns of the doped ferrites confirmed the formation of the M-type barium ferrite, and no other types of barium ferrite could be found. Based on the electromagnetic parameters measured by the vector net-analyzer, it was found that the composite (Ba(MnNi){sub 0.2}Co{sub 0.6}TiFe{sub 10}O{sub 19}) possessed a minimum reflection loss of −52.8 dB at 13.4 GHz with a matching thickness of 1.8 mm and the bandwidth below −15 dB was 5.8 GHz. Moreover, the maximum attenuation of Ba(MnNi){sub 0.25}Co{sub 0.5}TiFe{sub 10}O{sub 19} could reach −69 dB when its thickness was 1.8 mm, and also the bandwidth less than −20 dB was ranging from 13.2 GHz to 18 GHz. Thus, Ba(MnNi){sub 0.2}Co{sub 0.6}TiFe{sub 10}O{sub 19} and Ba(MnNi){sub 0.25}Co{sub 0.5}TiFe{sub 10}O{sub 19} could be the good microwave absorbers, which have great potentials to be applied in the high frequency fields of the microwave absorbing materials. - Highlights: • The Co was first time substituted by Mn–Ni in ferrites. • The substituted ferrites had good microwave absorption. • The doped ferrites had broad bandwidth and low reflection loss.

  13. Synthesis and Characterization of Barium-Vanadium Oxide Nanocomposite Using a Facile thermolysis Approach

    OpenAIRE

    Niloufar Akbarzadeh-T; Leila Amiri-O

    2015-01-01

    In this investigation, we report synthesis of new cationic-anionic Barium-Vanadium complex with 2, 6- pyridinedicarboxylic acid ligand. This compound [Ba(H2O)8][VO2(dipic)]2(1) has been characterized using elemental analyses, FT-IR, UV–Vis and Cyclic voltammetry (CV) techniques. Also in this study we report facile synthesis of Barium-Vanadium Oxide nanoparticle under thermal decomposition, using precursor complex (1). Characterization of Barium-Vanadium Oxide nanocomposites was carried out by...

  14. Barium ferrite nanoparticles prepared by self-propagating low-temperature combustion method and its characterization

    Indian Academy of Sciences (India)

    P M Prithviraj Swamy; S Basavaraja; Vijayanand Havanoor; N V Srinivas Rao; R Nijagunappa; A Venkataraman

    2011-12-01

    The barium ferrite particles were prepared using a self-propagating low-temperature combustion method using polyethylene glycol (PEG) as a fuel. The process was investigated with simultaneous thermogravimetric-differential thermal analysis (TG–DTA). The crystalline structure, morphology and the magnetic properties of the barium ferrite particles were studied by means of X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and SQUID susceptometer. The results show that the ignition temperature of PEG is lower compared with other combustion methods and gives nanocrystalline barium ferrite.

  15. A Comparative Study on Magnetostructural Properties of Barium Hexaferrite Powders Prepared by Polyethylene Glycol

    Directory of Open Access Journals (Sweden)

    Zehra Durmus

    2014-01-01

    Full Text Available Nanocrystalline particles of barium hexaferrite were synthesized by a sol-gel combustion route using nitrate-citrate gels prepared from metal nitrates and citric acid solutions with Fe/Ba molar ratio 12. The present paper aims to study the effect of addition of polyethylene glycol (PEG solutions with different molecular weights (MW: 400, 2000, and 10.000 g/mol on magnetostructural properties of barium hexaferrite. The formation of the barium hexaferrite was inspected using X-ray diffraction (XRD analysis, Fourier transform infrared (FT-IR analysis, thermogravimetric (TGA analysis, scanning electron microscopy (SEM analysis and vibrating sample magnetometer (VSM analysis for magnetic measurements.

  16. Microscopic insight into nuclear structure properties of proton-rich barium isotopes

    International Nuclear Information System (INIS)

    Variation after projection (VAP) calculations with Hartree-Bogoliubov (HB) Ansatz have been carried out for A=120-136 barium isotopes. In this framework, the yrast spectra with Jmaxπ=10+, B(E2) transition probabilities, quadrupole (β2) and hexadecapole (β4) deformation parameters for even-even barium isotopes have been obtained. The results of the calculation give an indication that it is important to include the hexadecapole-hexadecapole component of the two-body interaction for obtaining various nuclear structure quantities in these barium isotopes. (author)

  17. Orbital elements of barium stars formed through a wind accretion scenario

    CERN Document Server

    Liu, J H; Liang, Y C; Peng, Q H

    2000-01-01

    Taking the total angular momentum conservation in place of the tangential momentum conservation, and considering the square and higher power terms of orbital eccentricity e, the changes of orbital elements of binaries are calculated for wind accretion scenario. These new equations are used to quantitatively explain the observed (e,logP) properties of normal G, K giants and barium stars. Our results reflect the evolution from G, K giant binaries to barium binaries, moreover, the barium stars with longer orbital periods P>1600 days may be formed by accreting part of the ejecta from the intrinsic AGB stars through wind accretion scenario.

  18. The high-temperature sulphation behavior of barium-based sorbents during coal combustion

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, J.; Li, N.; Zhou, J.; Cao, X.; Liu, J.; Zhao, X.; Cen, K.

    2000-07-01

    In order to promote the sulfur removal efficiency during coal combustion, the high-temperature sulfation behavior of barium-based sorbents was studied. The sulfation product BaSO{sub 4} which did not decompose until 1,580 C had much better thermal stability than CaSO{sub 4} which rapidly decomposed at about 1,300 C. The desulfurization effect of barium salt Ba{sup 2+} was much better than calcium salt Ca{sup 2+} during coal combustion at about 1,200{approximately}1,300 C. The sulfur removal efficiency of barium-based sorbents could achieve 35.5% in industrial grate furnace.

  19. Application of barium fluoride for sulfur selective extraction at X-ray spectroscopic analysis of steel

    International Nuclear Information System (INIS)

    In order to increase the sensitivity of X-ray spectroscopic identification of sulphur in steels the application of barium fluoride for selective extraction of sulphate ions was proposed by authors of present work. The influence of concentration of sulphate ions, iron, nickel, chromium and titanium cations as well as acidity of solutions on the coefficient of distribution of sulphate ions in the system barium fluoride-water was studied. The distribution coefficients were calculated, the completeness of extraction was calculated as well. It is defined that sulphate ions from solutions containing cations of heavy metals and other anions can be extracted by means of barium fluoride.

  20. Flash radiographic technique applied to fuel injector sprays

    International Nuclear Information System (INIS)

    A flash radiographic technique, using 50 ns exposure times, was used to study the pattern and density distribution of a fuel injector spray. The experimental apparatus and method are described. An 85 kVp flash x-ray generator, designed and fabricated at the Lawrence Livermore Laboratory, is utilized. Radiographic images, recorded on standard x-ray films, are digitized and computer processed

  1. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic head holder. 892.1920 Section 892.1920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1920 Radiographic head holder....

  2. 21 CFR 892.1850 - Radiographic film cassette.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film cassette. 892.1850 Section 892.1850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette....

  3. 21 CFR 892.1640 - Radiographic film marking system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film marking system. 892.1640 Section 892.1640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1640 Radiographic film marking...

  4. 21 CFR 892.1950 - Radiographic anthropomorphic phantom.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic anthropomorphic phantom. 892.1950 Section 892.1950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1950 Radiographic...

  5. 21 CFR 892.1960 - Radiographic intensifying screen.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic intensifying screen. 892.1960 Section 892.1960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1960 Radiographic intensifying...

  6. 21 CFR 892.1890 - Radiographic film illuminator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film illuminator. 892.1890 Section 892.1890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator....

  7. 21 CFR 892.1860 - Radiographic film/cassette changer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film/cassette changer. 892.1860 Section 892.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1860 Radiographic...

  8. Prediction of osteoporosis using fractal analysis on periapical radiographs

    International Nuclear Information System (INIS)

    To purpose of this study was to investigate whether the fractal dimension and radiographic image brightness of periapical radiograph were useful in predicting osteoporosis. Ninety-two postmenopausal women were classified as normal, osteopenia and osteoporosis group according to the bone mineral density of lumbar vertebrae and periapical radiographs of both mandibular molar areas were taken. The ROIs of 358 areas were selected at periapical and interdental areas and fractal dimension and radiographic image brightness were measured. The fractal dimension in normal group was significantly higher than that in osteoporosis group at periapical ROI (p<0.05). The radiographic image brightness in normal group was higher than that in osteopenia and osteoporosis group. There was significant difference not only between normal and osteopenia group (p<0.05) but also within osteopenia and osteoporosis group (p<0.01) at periapical ROI. Significant difference was observed not only between normal and osteopenia group but also between normal and osteoporosis group at interdental ROI (p<0.01). Positive linear relationship was weakly shown at Pearson correlation analysis between fractal dimension and radiographic image brightness. BMD significantly correlated with fractal dimension at periapical ROI (p<0.01), and BMD and radiographic image brightness significantly correlated at both periapical and interdental ROIs (p<0.01). This study suggests that the fractal dimension and radiographic image brightness of periapical ROI may predict BMD.

  9. Common Errors on Conventional and Digital Panoramic Radiographs

    Directory of Open Access Journals (Sweden)

    Salemi

    2014-06-01

    Full Text Available Background Identification of common technical errors during preparation of panoramic radiographs, how affect the quality and interpretation of the radiographs and the techniques used to deal with such errors, might help prevent unnecessary radiation to patients and save their time and money. Objectives The current study aimed to identify common errors in the panoramic radiographs taken by post-graduate students in the Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Hamadan University of Medical Sciences. Patients and Methods A total of 220 conventional and digital panoramic radiographs of patients who were referred to the Department of Radiology were selected for the current study. All the radiographs had been taken by the post-graduate radiology students. The radiographs were evaluated by two oral and maxillofacial radiologists, under standard visualization conditions, to identify technical errors. Results From the evaluated radiographs, 193 (87.7% had one or more technical errors. The most common error was twisting of the head to one side (31.8%, followed by superimposition of the palatoglossus air space on the apices of maxillary incisors (30.9%. Conclusions The errors identified in the present study might be attributed to a lack of proper verbal communication between the patients and the post-graduate students, which necessitates continuous education of operators who take panoramic radiographs.

  10. 21 CFR 892.1900 - Automatic radiographic film processor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automatic radiographic film processor. 892.1900 Section 892.1900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... processor. (a) Identification. An automatic radiographic film processor is a device intended to be used...

  11. Radiologist perceptions of radiographer role development in Scotland

    International Nuclear Information System (INIS)

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training

  12. Precision assessment of osteoporosis from spine radiographs

    International Nuclear Information System (INIS)

    Inter- and intra-observer variation in spine radiographs of 100 osteoporotic women and longitudinal change in roentgenologic status after 1 year of anti-osteoporotic treatment were assessed. The method applied was naked eye inspection, and a score system estimating severity of fractures-vertebral deformation score (VDS). Agreement was assessed by the Kappa coefficient corrected for agreement by change. The results showed a satisfactory inter- and intra-observer agreement for wedge (Kappa=0.72 and 0.90) and compression fractures (Kappa=0.60 and 0.92). The method proved less reliable for endplate fractures (Kappa=0.39 and 0.73). The authors think that the method of investigation is well suited for monitoring treatment effects in longitudinal studies. (author). 16 refs.; 1 fig.; 2 tabs

  13. Radiographic studies of the ventricles in syringomyelia

    International Nuclear Information System (INIS)

    Radiographic investigations of 171 patients with communicating syringomyelia have been reviewed. Hydrocephalus was found in one third of the cases and has occasionally progressed after operation on the posterior fossa, sometimes with accompanying clinical deterioration. The outlets of the fourth ventricle were usually abnormal; tonsillar descent, arachnoiditis and both together were seen. Arachnoiditis correlated strongly with a history of difficult birth. The foramen of Magendie was sometimes patent and sometimes blocked. There was no consistent level of occulusion corresponding to a persistent roof of the fourth ventricle. The cisterna magna was usually small or obliterated but some examples of large cisterns or subarachnoid pouches were found. Radiological demonstration of a communication from the fourth ventricle to the syrinx occurred in only seven patients by positive contrast material and not by air. It is suggested that a sizable communication is rare at the time when patients seek treatment. (orig.)

  14. Iterative Reconstruction of Coded Source Neutron Radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Bingham, Philip R [ORNL; Gregor, Jens [University of Tennessee, Knoxville (UTK)

    2013-01-01

    Use of a coded source facilitates high-resolution neutron imaging through magnifications but requires that the radiographic data be deconvolved. A comparison of direct deconvolution with two different iterative algorithms has been performed. One iterative algorithm is based on a maximum likelihood estimation (MLE)-like framework and the second is based on a geometric model of the neutron beam within a least squares formulation of the inverse imaging problem. Simulated data for both uniform and Gaussian shaped source distributions was used for testing to understand the impact of non-uniformities present in neutron beam distributions on the reconstructed images. Results indicate that the model based reconstruction method will match resolution and improve on contrast over convolution methods in the presence of non-uniform sources. Additionally, the model based iterative algorithm provides direct calculation of quantitative transmission values while the convolution based methods must be normalized base on known values.

  15. Radiographic examination takes on an automated image

    International Nuclear Information System (INIS)

    Automation can be effectively applied to nondestructive testing (NDT). Until recently, film radiography used in NDT was largely a manual process, involving the shooting of a series of x-rays, manually positioned and manually processed. In other words, much radiographic work is being done the way it was over 50 years ago. Significant advances in automation have changed the face of manufacturing, and industry has shared in the benefits brought by such progress. The handling of parts, which was once responsible for a large measure of labor costs, is now assigned to robotic equipment. In nondestructive testing processes, some progress has been achieved in automation - for example, in real-time imaging systems. However, only recently have truly automated NDT begun to emerge. There are two major reasons to introduce automation into NDT - reliability and productivity. Any process or technique that can improve the reliability of parts testing could easily justify the capital investments required

  16. Predictive value of radiographic findings in gastritis

    International Nuclear Information System (INIS)

    In a retrospective review of biphasic upper gastrointestinal (GI) tract examinations in 300 consecutive patients with abdominal pain, blood loss, nausea and vomiting, weight loss or dysphagia, the author evaluated the frequency of radiographic findings suggestive of gastritis. Forty-eight patients had undergone endoscopy within 1 week of upper GI tract examination. ''Best findings'' were defined by receiver operating characteristic wave analysis of individual findings, including aphthous lesions, serrated or nodular folds, marginal spiculation, and luminal constriction. Most false negative studies were in the fundus or proximal body; most false positive studies were in the antrum. They present a pictorial dictionary of findings and data for use of ''best findings'' to improve sensitivity and specificity in the diagnosis of gastritis

  17. Computerized bone analysis of hand radiographs

    Science.gov (United States)

    Pietka, Ewa; McNitt-Gray, Michael F.; Hall, Theodore R.; Huang, H. K.

    1992-06-01

    A computerized approach to the problem of skeletal maturity is presented. The analysis of a computed radiography (CR) hand image results in obtaining features, that can be used to assess the skeletal age of pediatric patients. It is performed on a standard left hand radiograph. First, epiphyseal regions of interest (EROI) are located. Then, within each EROI the distals, middles, and proximals are separated. This serves as a basis to locate the extremities of epiphyses and metaphyses. Next, the diameters of epiphyses and metaphyses are calculated. Finally, an epiphyseal diameter and metaphyseal diameter ratio is calculated. A pilot study indicated that these features are sensitive to the changes of the anatomical structure of a growing hand and can be used in the skeletal age assessment.

  18. Spinal cord injury without radiographic abnormality

    Directory of Open Access Journals (Sweden)

    Singh Anil

    2006-01-01

    Full Text Available Spinal cord injury without radiological abnormality is rare in adults. Below we present a case report of 20 yrs old male with isolated cervical cord injury, without accompanying vertebral dislocation or fracture involving the spinal canal rim. He fell down on plain and smooth ground while carrying 40 kg weight overhead and developed quadriparesis with difficulty in respiration. Plain radiographs of the neck revealed no fractures or dislocations. MRI showed bulky spinal cord and an abnormal hyper intense signal on the T2W image from C2 vertebral body level to C3/4 intervertebral disc level predominantly in the anterior aspect of the cord The patient was managed conservatively with head halter traction and invasive ventilatory support for the initial 7 days period in the ICU. In our patient recovery was good and most of the neurological deficit improved over 4 weeks with conservative management.

  19. An exploratory study of radiographer's perceptions of radiographer commenting on musculo-skeletal trauma images in rural community based hospitals

    International Nuclear Information System (INIS)

    Aim: This study sought to explore the perceptions of community hospital based radiographers in North East Scotland regarding the practice of radiographer commenting on musculo-skeletal trauma images. Method: A purposive sample of radiographers (n = 8) were recruited from community hospitals throughout the North-east of Scotland. A qualitative, exploratory study was conducted employing semi-structured interviews consisting of one focus group and two individual interviews. The interviews were audio recorded and transcribed in full to allow thematic analysis of the data using a framework adapted from Pope and Mays (2006). Main findings: This study revealed that the practice of radiographer commenting in the community provides a valuable front line opinion on musculo-skeletal trauma image appearances to enhance diagnostic outcomes for patients and streamline their care pathway. The appreciation shown from inter-professional colleagues for this practice induced feelings of professional pride and job satisfaction in the sample group. All participants expressed a desire to undertake additional training to allow progression from radiographer commenting to radiographer reporting of musculo-skeletal trauma images. Perceived barriers to the practice of radiographer commenting were time constraints and a lack of support with regards to continuing professional development (CPD) opportunities and mentorship from radiology colleagues. Conclusion: The practice of radiographer commenting in the community setting should be supported by ongoing training, and radiologist involvement in mentoring could provide radiographers with a valuable support mechanism. The voice of all radiographers regarding this extended role must be heard by professional leaders to ensure that the skills and education required for radiographer commenting are provided and subsequent patient care is not compromised

  20. Mentoring assistant practitioners - The radiographer's perspective

    International Nuclear Information System (INIS)

    Purpose: The aim of this study was to evaluate the experiences of diagnostic and therapeutic radiographers as they mentored trainee assistant practitioners undertaking an educational programme. The evaluation study describes the challenges and benefits the radiographers experienced as mentors as well as giving their insights into the introduction of assistant practitioners in their departments. Method: The mentors' opinions were sought by a questionnaire which formed part of the evaluation of the respective diagnostic imaging and therapeutic educational programmes run by two colleges. Results: The response rate was 54% (22/41). Mentors described personal and professional benefits for themselves from undertaking this role. Although mentoring had provided a number of challenges including an increase in workload, the experience had also enhanced their teaching and mentoring skills and contributed to their Continuing Professional Development (CPD). Whilst the role was more time consuming than initially expected this had not impacted generally on their ability to undertake CPD or deliver patient care. In relation to the wider impact of the programmes some negative impact was reported on the speed of service delivery but not on the quality of practice. Mentors felt that the programmes had a positive effect on teamworking and had been beneficial for patient care. Some difficulties were noted in balancing the mentoring of trainee assistant practitioners and radiography undergraduates. Conclusion: The mentors strongly endorsed the educational programmes and their roles and responsibilities in their delivery. Protected time to carry out mentoring duties and establishing good communication with the colleges providing the theoretical teaching were identified as means of further improving the mentoring process.

  1. A radiographic study on temporomandibular joint trouble

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Byoung Woon; Ahn, Hyung Kyu [Dept. of Dental Radiology, Graduate School, Seoul National University, Seoul (Korea, Republic of)

    1979-11-15

    The purpose of this study was to investigate the radiographic images of Temporomandibular joint trouble patients. This study included 186 patients with the chief complaints of TMJ pain and dysfunction. Their age ranged from 17 to 68 years. All patients were identified in the department of Dental Radiology at the Infirmary of College of Dentistry, Seoul National University, during the period from Apr. 1978 to Jun. 1979. The author has observed the radiographic variations of two positions of condylar head taken by modified transcranial oblique-lateral projection, which are one in centric occlusion and the other in 1 inch(2.54 cm) mouth open. The results were obtained as follows; 1. In centric occlusion, the distances and positional relationship between the summit of condylar head and the deepest point of articular fossa revealed more or less large variations; Normal range is of 37.9%, anterior displacement of 37.3% and posterior displacement of 22.6%. 2. In the horizontal movement of condylar heads when on 1 inch mouth open, it was revealed that normal range was of 46.5%, anterior displacement of 12.3%, posterior displacement of 41.1%. 3. In the positional interrelationship of both condylar heads when on 1 inch mouth open, it was revealed that symmetry(71.5%) occurred approximately 2.5 times as many as asymmetry. 4. In both centric and 1 inch mouth open, it was showed that almost all estimated figures were greater in male than in female, and in the horizontal movement of condylar head when on 1 inch open, it was showed that hypermobility was dominant in male and hypomobility in female.

  2. Experiences of being a therapy radiographer

    Directory of Open Access Journals (Sweden)

    Chris Myburgh

    2011-02-01

    Full Text Available The purpose of this research was to explore and describe how therapy radiographers experience their profession. A qualitative, exploratory, descriptive and contextual design was utilised. The purposive sample consisted of 14 therapy radiographers employed at an academic hospital in Gauteng, South Africa. Data were collected using focus group interviews until data saturation was achieved. An appreciative inquiry interview technique was utilised, and data analysis was conducted by open coding to identify themes. Themes that were identified were life-giving forces that promote personal and professional engagement resulting in a sense of purpose; professional stagnation; and facilitating change through harnessing positive energy and commitment for change.

    Opsomming

    Die hoofdoel van hierdie navorsing is om te verken en beskryf hoe radioterapeute hulle beroep beleef. ‘n Kwalitatiewe, verkennende, beskrywende en kontekstuele navorsingsontwerp is gebruik. Die doelgerigte steekproef het bestaan uit 14 radioterapeute werksaam by ‘n akademiese hospitaal in Gauteng, Suid Afrika. Data is met behulp van fokusgroep onderhoude ingesamel totdat dataversadiging bereik is. ‘n ‘Appreciative inquiry’ onderhoudstegniek is gebruik met die stel van vrae, en data analise is met behulp van oop kodering gedoen om temas te identifiseer. Die temas wat geidentifiseer was is lewensgewende magte wat persoonlike en professionele betrokkenheid bevorder wat ‘n singewing tot gevolg het; professionele stagnering; en fasilitering van verandering deur die gebruikmaking van positiewe energie en toewyding vir verandering.

    How to cite this article: Lawrence, H., Poggenpoel, M. & Myburgh, C., 2011,‘Experiences of being a therapy radiographer’, Health SA Gesondheid 16(1, Art.#596. 7 pages. http://dx.doi. org/10.4102/hsag.v16i1.596

  3. A radiographic study on temporomandibular joint trouble

    International Nuclear Information System (INIS)

    The purpose of this study was to investigate the radiographic images of Temporomandibular joint trouble patients. This study included 186 patients with the chief complaints of TMJ pain and dysfunction. Their age ranged from 17 to 68 years. All patients were identified in the department of Dental Radiology at the Infirmary of College of Dentistry, Seoul National University, during the period from Apr. 1978 to Jun. 1979. The author has observed the radiographic variations of two positions of condylar head taken by modified transcranial oblique-lateral projection, which are one in centric occlusion and the other in 1 inch(2.54 cm) mouth open. The results were obtained as follows; 1. In centric occlusion, the distances and positional relationship between the summit of condylar head and the deepest point of articular fossa revealed more or less large variations; Normal range is of 37.9%, anterior displacement of 37.3% and posterior displacement of 22.6%. 2. In the horizontal movement of condylar heads when on 1 inch mouth open, it was revealed that normal range was of 46.5%, anterior displacement of 12.3%, posterior displacement of 41.1%. 3. In the positional interrelationship of both condylar heads when on 1 inch mouth open, it was revealed that symmetry(71.5%) occurred approximately 2.5 times as many as asymmetry. 4. In both centric and 1 inch mouth open, it was showed that almost all estimated figures were greater in male than in female, and in the horizontal movement of condylar head when on 1 inch open, it was showed that hypermobility was dominant in male and hypomobility in female.

  4. Stereoscopic radiographic images with gamma source encoding

    International Nuclear Information System (INIS)

    Conventional radiography with X-ray tube has several drawbacks, as the compromise between the size of the focal spot and the fluence. The finite dimensions of the focal spot impose a limit to the spatial resolution. Gamma radiography uses gamma-ray sources which surpass in size, portability and simplicity to X-ray tubes. However, its low intrinsic fluence forces to use extended sources that also degrade the spatial resolution. In this work, we show the principles of a new radiographic technique that overcomes the limitations associated with the finite dimensions of X-ray sources, and that offers additional benefits to conventional techniques. The new technique called coding source imaging (CSI), is based on the use of extended sources, edge-encoding of radiation and differential detection. The mathematical principles and the method of images reconstruction with the new proposed technique are explained in the present work. Analytical calculations were made to determine the maximum spatial resolution and the variables on which it depends. The CSI technique was tested by means of Monte Carlo simulations with sets of spherical objects. We show that CSI has stereoscopic capabilities and it can resolve objects smaller than the source size. The CSI decoding algorithm reconstructs simultaneously four different projections from the same object, while conventional radiography produces only one projection per acquisition. Projections are located in separate image fields on the detector plane. Our results show it is possible to apply an extremely simple radiographic technique with extended sources, and get 3D information of the attenuation coefficient distribution for simple geometry objects in a single acquisition. The results are promising enough to evaluate the possibility of future research with more complex objects typical of medical diagnostic radiography and industrial gamma radiography (author)

  5. Radiographic heart-volume estimation in normal cats

    International Nuclear Information System (INIS)

    Heart volume mensuration was evaluated on conventional radiographs from eight normal cats in different body positions using computed tomography (CT). Heart volumes were calculated from orthogonal thoracic radiographs in ventral and dorsal recumbency and from radiographs exposed with a vertical X-ray beam in dorsal and lateral recumbency using the formula for an ellipsoid body. Heart volumes were also estimated with CT in ventral, dorsal, right lateral and left lateral recumbency. No differences between heart volumes from CT in ventral recumbency and those from CT in right and left lateral recumbency were seen. In dorsal recumbency, however, significantly lower heart volumes were obtained. Heart volumes from CT in ventral recumbency were similar to those from radiographs in ventral and dorsal recumbency and dorsal/left lateral recumbency. Close correlation was also demonstrated between heart volumes from radiographs in dorsal/ left lateral recumbency and body weights of the eight cats

  6. Problems in radiographic detection and diagnosis of lung cancer.

    Science.gov (United States)

    Hayabuchi, N; Russell, W J; Murakami, J

    1989-01-01

    All chest radiographs of 107 proven lung cancer patients who received consecutive biennial chest radiography were reviewed to elucidate problems detecting their cancers, and diagnosing them when initially radiographically detected. Subjects, members of a fixed population sample, originally numbered 20,000 persons, 17,000 of whom consistently received consecutive biennial chest radiography during examinations for late effects of atomic-bomb radiation. Among the 107 subjects, 64 had radiographic manifestations of cancer; 47 were initially correctly diagnosed; 17 were not. Eleven of the 17 were initially equivocal, diagnosable only after subsequent radiography and retrospective review of serial radiographs. Diagnostic problems consisted of 1) six detection errors with cancer images superimposed on musculoskeletal and cardiovascular structures, reducible by stereoscopic p.a. instead of single p.a. radiography; immediate tentative interpretations; and by comparing earlier with current radiographs. 2) Eight decision errors, wherein cancers mimicked other diseases, were reducible by greater index of suspicion and scrutiny during interpretations. PMID:2923739

  7. Can the Physicians or Surgions Do without Chest Radiograph?

    Directory of Open Access Journals (Sweden)

    Mehrdad Bakhshayeshkaram

    2009-01-01

    Full Text Available   "nThe question is how much information is there in chest radiographs ? "nWe can consider the approximate heart size. Rough quantification of heart failure, very basic anatomy of the heart. The chest radiograph is widely available, cheap and very low long term risk of radiation. Chest radiographs are required in the initial consultation of heart or lung diseases. Follow-up radiographs are only required in certain situations. Chest radiographs contain significant information. But nowadays we look less critically, because it is easy to order echo, CT or MRI. Examples of frequently encountered abnormalities seen in our daily practice: "n-Change in hilar size or adenopathy "n-Alteration in hilar contour "n-Bronchial wall thickening "n-Obscuration of normal hilar structures "n   

  8. Methodology to evaluation of the density in radiographic image

    International Nuclear Information System (INIS)

    This study was designed in order to optimize the optical densitometry technique in radiographic images by the setorization of the characteristic curves of the radiographic films. We used 24 radiographs of a stepped aluminium wedge that were taken without rigorous control development and manually revealed. The densitometric values of the steps images and its thickness, for each radiographic, was utilized to generate its particular mathematics expressions that represent its characteristic densitometric curves and then it were used for setorization. The densitometric values were obtained by a Macbeth TD528 densitometer. The study showed an optimization in the representation of the relationship between the optical density of the steps images of the wedge and its correspondent thickness, provided by the setorization, with mean square error around 10-5. This optimization will allow the use of this methodology in quantitative evaluations of bone mass, by radiographic images. (author)

  9. Inferring Morphology and Strength of Magnetic Fields From Proton Radiographs

    CERN Document Server

    Graziani, Carlo; Lamb, Donald Q; Li, Chikang

    2016-01-01

    Proton radiography is an important diagnostic method for laser plasma experiments, and is particularly important in the analysis of magnetized plasmas. The theory of radiographic image analysis has heretofore only permitted somewhat limited analysis of the radiographs of such plasmas. We furnish here a theory that remedies this deficiency. We show that to linear order in magnetic field gradients, proton radiographs are projection images of the MHD current along the proton trajectories. We demonstrate that in the linear approximation, the full structure of the perpedicular magnetic field can be reconstructed by solving a steady-state inhomogeneous 2-dimensional diffusion equation sourced by the radiograph fluence contrast data. We explore limitations of the inversion method due to Poisson noise, to discretization errors, to radiograph edge effects, and to obstruction by laser target structures. We also provide a separate analysis that is well-suited to the inference of isotropic-homogeneous magnetic turbulence...

  10. Solvothermal synthesis and Curie temperature of monodispersed barium titanate nanoparticles

    International Nuclear Information System (INIS)

    Barium titanate (BaTiO3) nanoparticles with various particle sizes were prepared by a solvothermal method. X-ray powder diffraction (XRPD) patterns show that the as-prepared powders are of pure perovskite BaTiO3. Scanning electron microscopy (SEM) reveals that all the particles of BaTiO3 with different sizes are dispersed homogenously and have uniform size. The room temperature and in situ high temperature XRD analyses indicate that both the proportion of the tetragonal phase and the Curie temperature of BaTiO3 increase with increasing particles size. The effects of the reaction parameters, such as the concentration of reactants, the polarity of solvent, the reaction temperature and the amount of surfactant, on the size, morphology and uniformity of BaTiO3 nanoparticles are studied in detail.

  11. Infrared Spectroscopic Characterization of Calcium and Barium Hydrazone Complexes

    Directory of Open Access Journals (Sweden)

    *A. Adeniyi

    2013-06-01

    Full Text Available Hydrazones have attracted considerable interest on account of their biological activities. Introduction of calcium and barium metal ions into m- and p-nitrobenzoic hydrazones is expected to modify these biological properties for enhanced activity and versatility. The ligands were synthesized from the parent acids. The complexes have been characterized using C, H and N microanalyses and IR spectrometry. The IR spectral data of the ligands and complexes revealed bonding via the C=O and C=N groups. The suggested metal to ligand stoichiometries are: [M (m-NBHx]Cl2.yH2O, x, y = 1 and 4 for M = Ca; x, y = 2 and 3 for M = Ba respectively. [M(p-NBHx]Cl2.yH2O, x, y = 1 and 12 for M = Ca; x, y = 1 and 3 for M = Ba respectively. The structural deductions are tentative pending future X-ray structural studies.

  12. Preparation and Characterization of Nano-particle Substituted Barium Hexaferrite

    CERN Document Server

    Atassi, Yomen; Tally, Mohammad

    2014-01-01

    High density magnetic recording requires high coercivity magnetic media and small particle size. Barium hexaferrite has been considered as a leading candidate material because of its chemical stability, fairly large crystal anisotropy and suitable magnetic characteristics. In this work, we present the preparation of the hexagonal ferrite BaFe12O19 and one of its derivative; the Zn-Sn substituted hexaferrite by the chemical co-precipitation method. The main advantage of this method on the conventional glass-ceramic one, resides in providing a small enough particle size for magnetic recording. We demonstrate using the X-ray diffraction patterns that the particle size decreases when substituting the hexaferrite by the Zn-Sn combination. This may improve the magnetic properties of the hexaferrite as a medium for HD magnetic recording

  13. Synthesis and optical study of barium magnesium aluminate blue phosphors

    International Nuclear Information System (INIS)

    Europium doped barium magnesium aluminate (BaMgAl10O17:Eu2+) phosphor was prepared via solution combustion method at 550°C using urea as a fuel. Morphological and optical properties of the prepared sample was studied by X-ray diffraction (XRD), Transmission electron microscopy (TEM) and Photoluminescence spectroscopy (PL). XRD result showed the formation of pure phase BaMgAl10O17(JCPDS 26-0163) along with an additional phase BaAl2O4(JCPDS 01-082-1350). TEM image indicated the formation of faceted particles with average particle size 40 nm. From PL spectra, a broad emission band obtained at about 450 nm attributes to 4f6 5d → 4f7 transition of Eu2+ which lies in the blue region of the visible spectrum

  14. Conoscopic study of strontium-barium niobate single crystals

    International Nuclear Information System (INIS)

    Optically transparent single crystals of strontium-barium niobate, SrxBa1-xNb2O6, of different compositions (x = 0.26...0.7) were examined with the aid of conoscopic light interference figures. A regular change of the isochrome concentric ring number and diameters consistent with the temperature variation of the value of birefringence is demonstrated by direct observations of polar cuts of optically uniaxial samples. Anomalous violations of the conventional (uniaxial) interference patterns occur occasionaly in some samples being indicative of the existence of biaxial trait in their behaviour even though no voltage is applied. These features may depend on annealing treatments at elevated temperatures. The results of the study show that conoscopic images may serve as a sensitive indicator of the structural state of SBN crystals related to the effects of stress–induced change of optical anisotropy and temperature dependent birefringence parameters

  15. Pulsating aurora induced by upper atmospheric barium releases

    Science.gov (United States)

    Deehr, C.; Romick, G.

    1977-01-01

    The paper reports the apparent generation of pulsating aurora by explosive releases of barium vapor near 250 km altitude. This effect occurred only when the explosions were in the path of precipitating electrons associated with the visible aurora. Each explosive charge was a standard 1.5 kg thermite mixture of Ba and CuO with an excess of Ba metal which was vaporized and dispersed by the thermite explosion. Traces of Sr, Na, and Li were added to some of the charges, and monitoring was achieved by ground-based spectrophotometric observations. On March 28, 1976, an increase in emission at 5577 A and at 4278 A was observed in association with the first two bursts, these emissions pulsating with roughly a 10 sec period for approximately 60 to 100 sec after the burst.

  16. Behaviour of barium and strontium oxides in liquid nitrogen tetroxide

    International Nuclear Information System (INIS)

    Chemical transformations of barium and strontium oxides (MeO, MeO2) in liquid nitrogen tetroxide are considered in the temperature range of 290-493 K. The data on IR and Raman spectra of the reaction products in the region of 2500-600 cm-1 are presented. No formation of nitrosonium complexes of the type NO[Me(NOsub(3))sub(n)]sub(m) and adducts of the type Me(NO3)2xmN2O4 is detected. It has been established that MeO2 possess a higher reactivity in liquid nitrogen tetroxide than MeO. Using the methods of vibrational spectroscopy the bands, characteristic of MeO2 are signled out in MeO samples being in contact with nitrogen tetroxide

  17. Stark effect in Rydberg states of helium and barium

    International Nuclear Information System (INIS)

    This thesis, which deals with the effect of an electric field up to moderate field strengths on atoms with two valence electrons outside closed shells, in casu helium and barium, contains chapter in which the linear Stark effect in the 1 snp 1,3p Rydberg states of helium (n around 40) has been studied in a CW laser-atomic beam experiment. The evolution of the angular momentum manifolds into the n-mixing regime was followed and avoided level crossings were observed. Stark manifolds were also calculated by diagonalization of the complete energy matrix in the presence of an electric field. It turned out to be necessary to include up to five n-values in the calculations already at moderate values of the field to reproduce the data within the experimental accuracy (a few MHz), especially in the regime of the avoided crossings. (author). 147 refs.; 30 figs.; 8 tabs

  18. Small polarons and point defects in barium cerate

    Science.gov (United States)

    Swift, Michael; Janotti, Anderson; Van de Walle, Chris G.

    2015-12-01

    Barium cerate (BaCeO3) is a well-known ionic conductor of both hydrogen and oxygen. In applications, it is frequently doped (for instance with Y) to increase stability and promote diffusion. However, the effects of doping and native defects are not fully understood. Computational studies have been stymied by the nature of the conduction band, which is made up of cerium 4 f states. These states present a challenge to ab initio techniques based on density functional theory within the standard approximations for exchange and correlation. Using a hybrid functional, we investigate the effects of hydrogen impurities and native defects on the electrical and optical properties of BaCeO3. We discuss the tendency of excess electrons or holes to localize in the form of small polarons. We also explore the interactions of polarons with hydrogen impurities and oxygen vacancies, and their impact on luminescence properties.

  19. Nonlinear optical properties of calcium barium niobate epitaxial thin films.

    Science.gov (United States)

    Bancelin, Stéphane; Vigne, Sébastien; Hossain, Nadir; Chaker, Mohammed; Légaré, François

    2016-07-25

    We investigate the potential of epitaxial calcium barium niobate (CBN) thin film grown by pulsed laser deposition for optical frequency conversion. Using second harmonic generation (SHG), we analyze the polarization response of the generated signal to determine the ratios d15 / d32 and d33 / d32 of the three independent components of the second-order nonlinear susceptibility tensor in CBN thin film. In addition, a detailed comparison to the signal intensity obtained in a y-cut quartz allows us to measure the absolute value of these components in CBN thin film: d15 = 5 ± 2 pm / V, d32 = 3.1 ± 0.6 pm / V and d33 = 9 ± 2 pm / V. PMID:27464195

  20. Barium titanate nanocomposite capacitor FY09 year end report.

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, Tyler E.; DiAntonio, Christopher Brian; Yang, Pin; Chavez, Tom P.; Winter, Michael R.; Monson, Todd C.; Roesler, Alexander William; Fellows, Benjamin D.

    2009-11-01

    This late start RTBF project started the development of barium titanate (BTO)/glass nanocomposite capacitors for future and emerging energy storage applications. The long term goal of this work is to decrease the size, weight, and cost of ceramic capacitors while increasing their reliability. Ceramic-based nanocomposites have the potential to yield materials with enhanced permittivity, breakdown strength (BDS), and reduced strain, which can increase the energy density of capacitors and increase their shot life. Composites of BTO in glass will limit grain growth during device fabrication (preserving nanoparticle grain size and enhanced properties), resulting in devices with improved density, permittivity, BDS, and shot life. BTO will eliminate the issues associated with Pb toxicity and volatility as well as the variation in energy storage vs. temperature of PZT based devices. During the last six months of FY09 this work focused on developing syntheses for BTO nanoparticles and firing profiles for sintering BTO/glass composite capacitors.

  1. Ultrasonic de-agglomeration of barium titanate powder.

    Science.gov (United States)

    Marković, S; Mitrić, M; Starcević, G; Uskoković, D

    2008-01-01

    BaTiO3 (BT) powder, with average particle size of 1.4 microm, was synthesized by solid-state reaction. A high-intensity ultrasound irradiation (ultrasonication) was used to de-agglomerate micro-sized powder to nano-sized one. The crystal structure, crystallite size, morphology, particle size, particle size distribution, and specific surface area of the BT powder de-agglomerated for different ultrasonication times (0, 10, 60, and 180 min) were determined. It was found that the particles size of the BT powder was influenced by ultrasonic treatment, while its tetragonal structure was maintained. Therefore, ultrasonic irradiation can be proposed as an environmental-friendly, economical, and effective tool for the de-agglomeration of barium titanate powders. PMID:17845864

  2. Synthesis and optical study of barium magnesium aluminate blue phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Jeet, Suninder, E-mail: suninder.jeet@thapar.edu; Pandey, O. P., E-mail: oppandey@thapar.edu [School of Physics and Materials Science, Thapar University, Patiala (147003), Punjab (India); Sharma, Manoj, E-mail: manojnarad@sggswu.org [Department of Nanotechnology, Sri Guru Granth Sahib World University, Fatehgarh Sahib(146406), Punjab (India)

    2015-05-15

    Europium doped barium magnesium aluminate (BaMgAl{sub 10}O{sub 17}:Eu{sup 2+}) phosphor was prepared via solution combustion method at 550°C using urea as a fuel. Morphological and optical properties of the prepared sample was studied by X-ray diffraction (XRD), Transmission electron microscopy (TEM) and Photoluminescence spectroscopy (PL). XRD result showed the formation of pure phase BaMgAl{sub 10}O{sub 17}(JCPDS 26-0163) along with an additional phase BaAl{sub 2}O{sub 4}(JCPDS 01-082-1350). TEM image indicated the formation of faceted particles with average particle size 40 nm. From PL spectra, a broad emission band obtained at about 450 nm attributes to 4f{sup 6} 5d → 4f{sup 7} transition of Eu{sup 2+} which lies in the blue region of the visible spectrum.

  3. Barium depletion study on impregnated cathodes and lifetime prediction

    Science.gov (United States)

    Roquais, J. M.; Poret, F.; le Doze, R.; Ricaud, J. L.; Monterrin, A.; Steinbrunn, A.

    2003-06-01

    In the thermionic cathodes used in cathode ray-tubes (CRTs), barium is the key element for the electronic emission. In the case of the dispenser cathodes made of a porous tungsten pellet impregnated with Ba, Ca aluminates, the evaporation of Ba determines the cathode lifetime with respect to emission performance in the CRT. The Ba evaporation results in progressive depletion of the impregnating material inside the pellet. In the present work, the Ba depletion with time has been extensively characterized over a large range of cathode temperature. Calculations using the depletion data allowed modeling of the depletion as a function of key parameters. The link between measured depletion and emission in tubes has been established, from which an end-of-life criterion was deduced. Taking modeling into account, predicting accelerated life-tests were performed using high-density maximum emission current (MIK).

  4. Barium depletion study on impregnated cathodes and lifetime prediction

    International Nuclear Information System (INIS)

    In the thermionic cathodes used in cathode ray-tubes (CRTs), barium is the key element for the electronic emission. In the case of the dispenser cathodes made of a porous tungsten pellet impregnated with Ba, Ca aluminates, the evaporation of Ba determines the cathode lifetime with respect to emission performance in the CRT. The Ba evaporation results in progressive depletion of the impregnating material inside the pellet. In the present work, the Ba depletion with time has been extensively characterized over a large range of cathode temperature. Calculations using the depletion data allowed modeling of the depletion as a function of key parameters. The link between measured depletion and emission in tubes has been established, from which an end-of-life criterion was deduced. Taking modeling into account, predicting accelerated life-tests were performed using high-density maximum emission current (MIK)

  5. Structural and functional characterization of barium zirconium titanate / epoxy composites

    Directory of Open Access Journals (Sweden)

    Filiberto González Garcia

    2011-12-01

    Full Text Available The dielectric behavior of composite materials (barium zirconium titanate / epoxy system was analyzed as a function of ceramic concentration. Structure and morphologic behavior of the composites was investigated by X-ray Diffraction (XRD, Fourier transformed infrared spectroscopy (FT-IR, Raman spectroscopy, field emission scanning electron microscopy (FE-SEM and transmission electron microscopy (TEM analyses. Composites were prepared by mixing the components and pouring them into suitable moulds. It was demonstrated that the amount of inorganic phase affects the morphology of the presented composites. XRD revealed the presence of a single phase while Raman scattering confirmed structural transitions as a function of ceramic concentration. Changes in the ceramic concentration affected Raman modes and the distribution of particles along into in epoxy matrix. Dielectric permittivity and dielectric losses were influenced by filler concentration.

  6. Gamma radiation induced darkening in barium gallo-germanate glass.

    Science.gov (United States)

    Chen, Xiaodong; Heng, Xiaobo; Tang, Guowu; Zhu, Tingting; Sun, Min; Shan, Xiujie; Wen, Xin; Guo, Jingyuan; Qian, Qi; Yang, Zhongmin

    2016-05-01

    Barium gallo-germanate (BGG) glass is an important glass matrix material used for mid-infrared transmission and mid-infrared fiber laser. In this study, we investigated the γ-ray irradiation induced darkening effect of BGG glass. Optical transmittance spectra, electron paramagnetic resonance (EPR) and thermoluminescence (TL) spectra were employed to investigate the γ-ray irradiation induced defects. Two kinds of Ge-related defects in the irradiated BGG glass, named Ge-related non-bridging oxygen hole center (Ge-NBOHC) and Ge-related electron centers (GEC), were verified. In addition, the absorption bands of the two defects have been separated and the peak absorptivity of Ge-NBOHC and GEC defects is at 375 nm and 315 nm, respectively. PMID:27137531

  7. Effect of Nb on barium titanate prepared from citrate solutions

    Directory of Open Access Journals (Sweden)

    Stojanović Biljana D.

    2002-01-01

    Full Text Available The influence of the addition of dopants on the microstructure development and electrical properties of BaTiO3 doped with 0.2, 0.4, 0.6, 0.8 mol% of Nb and 0.01 mol% of Mn based compounds was studied. Doped barium titanate was prepared using the polymeric precursor method from citrate solutions. The powders calcined at 700°C for 4 hours were analysed by infrared (IR spectroscopy to verify the presence of carbonates, and by X-ray diffraction (XRD for phase formation. The phase composition, microstructure and dielectric properties show a strong dependence on the amount of added niobium.

  8. Ionoluminescence of trivalent rare-earth-doped strontium barium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Calvo del Castillo, H. [Departamento de Geologia y Geoquimica, Universidad Autonoma de Madrid, Modulo C-VI, Campus de Cantoblanco, 28049 Cantoblanco, Madrid (Spain); Universidad Nacional Automoma de Mexico, Instituto de Fisica, 04510 Ciudad Universitaria, Mexico D.F. (Mexico); Ruvalcaba, J.L. [Universidad Nacional Automoma de Mexico, Instituto de Fisica, 04510 Ciudad Universitaria, Mexico D.F. (Mexico); Bettinelli, M.; Speghini, A. [Dipartimento Scientifico e Tecnologico, Universita di Verona and INSTM, UdR Verona, Ca Vignal, Strada Le Grazie 15, I-37134 Verona (Italy); Barboza Flores, M. [Centro de Investigacion en Fisica, Universidad de Sonora, Hermosillo, Sonora (Mexico); Calderon, T. [Departamento de Geologia y Geoquimica, Universidad Autonoma de Madrid, Modulo C-VI, Campus de Cantoblanco, 28049 Cantoblanco, Madrid (Spain)], E-mail: tomas.calderon@uam.es; Jaque, D.; Garcia Sole, J. [Departamento de Fisica de Materiales, Universidad Autonoma de Madrid, 28049 Cantoblanco, Madrid (Spain)

    2008-05-15

    Ionoluminescence spectra for different rare-earth ion (Pr{sup 3+} and Eu{sup 3+})-activated Sr{sub x}Ba{sub 1-x}Nb{sub 2}O{sub 6} strontium barium niobate crystals (x=0.33 and 0.60) have been induced with a 3 MeV proton beam for a variety of beam current intensities (45, 40 and 20 nA). The proton-beam induced luminescent spectra have shown features associated with the presence of the rare-earth ion and some spectral features mostly related to the host crystal, which appear only for high beam current intensities. We have compared the ionoluminescence results to those obtained under UV light excitation (photoluminescence technique) where a direct excitation of the band gap would occur.

  9. Microwave absorption properties of barium titanate/epoxide resin composites

    International Nuclear Information System (INIS)

    Nano-barium titanate (BT) was prepared by a sol-gel method. The prepared powders were characterized by x-ray powder diffraction and transmission electron microscopy. The complex relative dielectric permittivity (ε = ε' - jε-prime) and magnetic permeability (μ = μ' - jμ-prime) of the BT powders were measured in the frequency range 8 ∼ 18 GHz. The BT/epoxide resin (EP) composite with different volume contents was investigated. The effects of thickness on the BT/EP composite were studied. It was found that an optimum thickness and contents of the absorber can yield the maximum reflection loss which could be obtained over a broad frequency region in the X and Ku bands. Our results indicate that BT could be a promising microwave absorption material

  10. Study on a flexoelectric microphone using barium strontium titanate

    Science.gov (United States)

    Kwon, S. R.; Huang, W. B.; Zhang, S. J.; Yuan, F. G.; Jiang, X. N.

    2016-04-01

    In this study, a flexoelectric microphone was, for the first time, designed and fabricated in a bridge structure using barium strontium titanate (Ba0.65Sr0.35TiO3) ceramic and tested afterwards. The prototyped flexoelectric microphone consists of a 1.5 mm  ×  768 μm  ×  50 μm BST bridge structure and a silicon substrate with a cavity. The sensitivity and resonance frequency were designed to be 0.92 pC/Pa and 98.67 kHz, respectively. The signal to noise ratio was measured to be 74 dB. The results demonstrate that the flexoelectric microphone possesses high sensitivity and a wide working frequency range simultaneously, suggesting that flexoelectricity could be an excellent alternative sensing mechanism for microphone applications.

  11. Enthalpy of formation of (In, Gd)-doped barium cerate

    International Nuclear Information System (INIS)

    Highlights: • BaCe0.7Gd0.2In0.1O2.85 was prepared by solid-state reaction. • The standard formation enthalpy was determined. • The stabilization energy (ΔstH°) was calculated. • ΔstH° of BaCe0.7Gd0.2In0.1O2.85 is higher than BaCe0.7Nd0.2In0.1O2.85 and BaCeO3. - Abstract: Solution enthalpies of barium cerate doped by gadolinium and indium and a mixture of BaCl2 + 0.7CeCl3 + 2GdCl3 + 0.1InCl3 have been measured in 1 mol dm−3 HCl with 0.1 mol dm−3 KI. For the first time the standard molar formation enthalpy of BaCe0.7Gd0.2In0.1O2.85 has been determined by solution calorimetry as follows: ΔfH° (298.15 K) = −1615.84 ± 9.01 kJ mol−1. The stabilization energy for above-mentioned compound has been calculated as well. It has been shown that barium cerate doped gadolinium and indium has higher stabilization energy than BaCe0.7Nd0.2In0.1O2.85 and BaCeO3. The reaction enthalpy with CO2 interaction has been calculated for BaCe0.7Gd0.2In0.1O2.85

  12. Brillouin function characteristics for La-Co substituted barium hexaferrites

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Chuanjian, E-mail: wcjuestc2005@gmail.com, E-mail: ksun@uestc.edu.cn; Yu, Zhong; Sun, Ke, E-mail: wcjuestc2005@gmail.com, E-mail: ksun@uestc.edu.cn; Guo, Rongdi; Jiang, Xiaona; Lan, Zhongwen [State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054 (China); Yang, Yan [Department of Communication and Engineering, Chengdu Technological University, Chengdu 611730 (China)

    2015-09-14

    La-Co substituted barium hexaferrites with the chemical formula of Ba{sub 1−x}La{sub x}Fe{sub 12−x}Co{sub x}O{sub 19} (x = 0.0, 0.1, 0.3, and 0.5), prepared by a conventional ceramic method, were systematically investigated by Raman spectra, X-ray photoelectron spectroscopy, Rietveld refinement of X-ray diffraction patterns, and vibrating sample magnetometer. The result manifests that all the compounds are crystallized in magnetoplumbite hexagonal structure. Trivalent cobalt ions prevailingly occupy the 2a, 4f{sub 1}, and 12k sites. According to Néel model of collinear-spin ferrimagnetism, the molecular-field coefficients ω{sub bf2}, ω{sub kf1}, ω{sub af1}, ω{sub kf2}, and ω{sub bk} of La-Co substituted barium hexaferrites have been calculated using the nonlinear fitting method, and the magnetic moment of five sublattices (2a, 2b, 4f{sub 1}, 4f{sub 2}, and 12k) versus temperature T has been also investigated. The fitting results are coincided well with the experimental data. Moreover, with the increase of La-Co substitution amount x, the molecular-field coefficients ω{sub bf2} and ω{sub af1} decrease constantly, while the molecular-field coefficients ω{sub kf1}, ω{sub kf2}, and ω{sub bk} show a slight change.

  13. Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

    OpenAIRE

    Kose, Taha Emre; DEMIRTAS, Nihat; Cakir Karabas, Hulya; Ozcan, Ilknur

    2015-01-01

    PURPOSE The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atroph...

  14. Sensitivity of single contrast barium enema with regard to colorectal disease as diagnosed by colonoscopy

    International Nuclear Information System (INIS)

    The results of single contrast barium enema were retrospectively correlated with colonoscopically diagnosed colorectal disease in 54 patients (75 lesions). Altogether 66 lesions (88%) were correctly diagnosed. The sensitivity of barium enema for polyps was 81% (26/32). There were three perceptive errors and three polyps 5 mm or less in size were not demonstrated by barium enema. Twenty-nine cases of inflammatory disorders were all correctly diagnosed. One of 12 malignancies was missed by perceptive error. In two cases with vascular malformations the barium enema was normal. 4/9 (44%) of missed lesions were perceptive errors and could have been probably avoided by a second independent reading of films. (orig.)

  15. How changes in a radiologist's technique can reduce patient dose in barium enema studies

    International Nuclear Information System (INIS)

    Changes in a radiologist's technique, especially utilising digital technology, can lead to substantial dose savings in barium enema examinations. Data will be provided showing a 20% saving with only minimal change in technique. (author)

  16. Barium isotopes in Allende meteorite - Evidence against an extinct superheavy element

    Science.gov (United States)

    Lewis, R. S.; Anders, E.; Shimamura, T.; Lugmair, G. W.

    1983-01-01

    Carbon and chromite fractions from the Allende meteorite that contain isotopically anomalous xenon-131 to xenon-136 (carbonaceous chondrite fission or CCF xenon) at up to 5 x 10 to the 11th atoms per gram show no detectable isotopic anomalies in barium-130 to barium-138. This rules out the possibility that the CCF xenon was formed by in situ fission of an extinct superheavy element. Apparently the CCF xenon and its carbonaceous carrier are relics from stellar nucleosynthesis.

  17. Calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid

    International Nuclear Information System (INIS)

    Present article is devoted to calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid. The calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid was carried out in order to determine the thermal effects of reactions. The results of interaction of Ba(OH)4·8H2O with 5, 10, and 20% solution of hydrofluoric acid were considered.

  18. Comparison of barium swallow and ultrasound in diagnosis of gastro-oesophageal reflux in children.

    OpenAIRE

    Naik, D R; Bolia, A; Moore, D. J.

    1985-01-01

    Fifty one infants and older children with suspected gastro-oesophageal reflux entered a study comparing the diagnostic accuracy of a standard barium swallow examination with that of ultrasound scanning. All children were examined by both techniques. In 40 cases there was unequivocal agreement between the examinations. Of the remaining patients, four had definite reflux by ultrasonic criteria but showed no evidence of reflux on barium swallow examination, four had positive findings on ultrasou...

  19. Whipple's disease demonstrated by double contrast small bowel enema with barium and methylcellulose

    International Nuclear Information System (INIS)

    The radiologic findings on small bowel enema examination using barium and methylcellulose (SBE+Ba+MC) in a patient with Whipple's disease before and after treatment are described. The changes on SBE+Ba+MC corresponded well to the clinical and morphologic picture. The advantages of this double contrast technique compared to the enteroclysis with barium alone are demonstrated. The SBE+Ba+MC is a good method to demonstrate the manifestations of Whipple's disease involving the small bowel and the mesentery. (orig.)

  20. Impact of Biofield Treatment on Atomic and Structural Characteristics of Barium Titanate Powder

    OpenAIRE

    Trivedi, Mahendra; Nayak, Gopal

    2015-01-01

    Barium titanate, perovskite structure is known for its high dielectric constant and piezoelectric properties, which makes it interesting material for fabricating capacitors, transducer, actuator, and sensors. The perovskite crystal structure and lattice vibrations play a crucial role in its piezoelectric and ferroelectric behavior. In the present study, the barium titanate powder was subjected to biofield treatment. Further, the control and treated samples were characterized using X-ray diffr...

  1. Kinetics of barium sulphate reaction crystallization in crystallizers with internal circulation

    OpenAIRE

    Koralewska, J.; Piotrowski, K; B. Wierzbowska; A. Matynia

    2008-01-01

    Kinetic calculation results describing the observed nucleation and growth rates of barium sulphate crystals precipitated in an integrated reaction-crystallization process in a barium sulphate-ammonium chloride-water system are presented and analyzed. The scope of experiments included two continuous model DTM-type crystallizers (Draft Tube Magma) with internal circulation of the suspension forced by a liquid jet-pump device responsible for stable and intensive enough ascending/descending flow ...

  2. Relationship between stress ankle radiographs and injured ligaments on MRI

    International Nuclear Information System (INIS)

    This study was performed to investigate the relationship between the injured lateral ankle ligaments on MRI and stress ankle radiographs. Two hundred and twenty-nine consecutive patients (mean age 35.5 years, SD 14.6 years; 136 males and 93 females) that underwent ankle stress radiographs and MRI for lateral ankle instability were included. Tibiotalar tilt angle and anterior translation of talus were measured on stress ankle radiographs. Degree of lateral ligaments (anterior talofibular, calcaneofibular, and posterior talofibular) and deltoid ligament injuries were evaluated and scored as intact (0), partial injury (1), and complete injury (2) on MR images. Effusion of ankle joint was also recorded. The effects of gender, age, injuries of ligaments, and ankle joint effusion on stress radiographs were statistically analyzed. Gender (p = 0.010), age (p = 0.020), and anterior talofibular ligament (ATFL) injury (p < 0.001) were the factors significantly affecting tibiotalar tilt angle. Posterior talofibular ligament (PTFL) injury (p = 0.014) was found to be the only significant factor affecting the anterior translation on the anterior drawer radiographs. ATFL injury and PTFL injury on MRI significantly affected tibiotalar tilt angle and anterior drawer on stress radiographs. Other factors, such as age and gender, need to be considered in evaluating radiographic lateral ankle instability. (orig.)

  3. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    International Nuclear Information System (INIS)

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs

  4. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  5. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Mahdian, Mina; Sheth, Sonam; Chandhoke, Taranpreet K.; Gopalakrishna, Aadarsh; Potluri, Anitha; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

  6. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  7. Relationship between stress ankle radiographs and injured ligaments on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyoung Min; Chung, Chin Youb; Chung, Myung Ki; Won, Sung Hun; Lee, Seung Yeol; Park, Moon Seok [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Kyungki (Korea, Republic of); Kwon, Soon-Sun [Seoul National University Bundang Hospital, Biomedical Research Institute, Kyungki (Korea, Republic of)

    2013-11-15

    This study was performed to investigate the relationship between the injured lateral ankle ligaments on MRI and stress ankle radiographs. Two hundred and twenty-nine consecutive patients (mean age 35.5 years, SD 14.6 years; 136 males and 93 females) that underwent ankle stress radiographs and MRI for lateral ankle instability were included. Tibiotalar tilt angle and anterior translation of talus were measured on stress ankle radiographs. Degree of lateral ligaments (anterior talofibular, calcaneofibular, and posterior talofibular) and deltoid ligament injuries were evaluated and scored as intact (0), partial injury (1), and complete injury (2) on MR images. Effusion of ankle joint was also recorded. The effects of gender, age, injuries of ligaments, and ankle joint effusion on stress radiographs were statistically analyzed. Gender (p = 0.010), age (p = 0.020), and anterior talofibular ligament (ATFL) injury (p < 0.001) were the factors significantly affecting tibiotalar tilt angle. Posterior talofibular ligament (PTFL) injury (p = 0.014) was found to be the only significant factor affecting the anterior translation on the anterior drawer radiographs. ATFL injury and PTFL injury on MRI significantly affected tibiotalar tilt angle and anterior drawer on stress radiographs. Other factors, such as age and gender, need to be considered in evaluating radiographic lateral ankle instability. (orig.)

  8. A radiographic study of solitary bone cysts

    International Nuclear Information System (INIS)

    The aim of this study was to evaluate the clinical, radiographic and histopathologic features of 23 cases of solitary bone cyst by means of the analysis of radiographs and biopsy specimens in 23 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chunbuk National University. The obtained results were as follows; 1. The incidence of solitary bone cyst was almost equal in males (52.2%) and in females(42.8%) and the prevalent age of the solitary bone cyst were the second decade (47.8%) and the third decade (21.7%). 2. In the signs and symptoms of solitary bone cyst, pain or tenderness revealed in 17.4%, swelling revealed in 13.0%, pain and swelling revealed in 21.7%, paresthesia revealed in 4.4% and 43.5% were a symptom and the tooth vitality involved in the solitary bone cyst, 76.5% were posterior and 23.5% were either positive or negative. 3. In the location of the solitary bone cyst, 47.8% present posterior region, 21.7% present anterior region, 21.6% present anterior and posterior region, 4.4% present condylar process area. 4. In the hyperostotic border of the solitary bone cyst, 47.8% were seen entirely, 21.8% were seen partially, and 30.4% were not seen. 5. In the change of tooth, 59.1% were loss of the alveolar lamina dura, 13.6% were root resorption 4.55% were tooth displacement, 4.55% were root resorption and tooth displacement. 6. In the change of cortical bone of the solitary bone cyst, 39.1% were intact and 60.9% were thinning and expansion of cortical bone. 7. In the histopathologic findings of 9 cases, 33.3% were thin connective tissue wall, 11.1% were thickened myxo-fibromatous wall, 55.6% were thickened myxofibromatous wall with dysplastic bone formation.

  9. The impact of digital imaging on patient doses during barium studies

    International Nuclear Information System (INIS)

    Barium studies performed on 10 digital and four non-digital fluoroscopic systems were monitored with dose-area product meters as part of a Regional Patient Dosimetry Audit programme. The data have been collected using a computer to read and reset the dose-area product meter and also to collect patient and examination details. A comparison of dose-area product measurements from digital and non-digital fluoroscopy units on over 10 000 barium studies is presented. The data have been corrected according to patient size. The mean size corrected dose-area product for a barium meal examination was found to be 7.62 Gy cm-2 for a digital set compared with 15.45 Gy cm-2 for a non-digital set with 2462 and 1308 patients included in each measurement series, respectively. Dose-area products were also a factor of approximately two lower for barium enema, barium swallow and barium follow-through examinations performed on digital systems. (author)

  10. Preparation of porous nano barium ferrite and its adsorption properties on uranium

    International Nuclear Information System (INIS)

    The porous nano barium ferrite was made of Fe(NO3)3 and Ba(NO3)2 as raw materials, CTAB as surfactant by method of sol-gel and self-propagating combustion. The composition, morphology and magnetic properties of nano-rod barium ferrite were characterized by XRD, SEM and vibrating sample magnetometer. The adsorption properties of porous nano barium ferrite on uranium were studied with static adsorption and the effects of pH, adsorption temperature and oscillation time on adsorption properties were discussed. The results indicate that the average particle size of porous nano barium ferrite is 45-65 nm, the saturation magnetization and coercivity are 62.83 emu/g and 5481.0 Oe, respectively. Under the condition of the porous nano barium ferrite amount of 0.02 g, pH of 6, adsorption temperature of 25℃ and oscillation time of 30 min, the adsorption capacity of uranium on the porous nano barium ferrite reaches 921 μg/g. (authors)

  11. Comparison of Calcium and Barium Microcapsules as Scaffolds in the Development of Artificial Dermal Papillae.

    Science.gov (United States)

    Liu, Yang; Lin, Changmin; Zeng, Yang; Li, Haihong; Cai, Bozhi; Huang, Keng; Yuan, Yanping; Li, Yu

    2016-01-01

    This study aimed to develop and evaluate barium and calcium microcapsules as candidates for scaffolding in artificial dermal papilla. Dermal papilla cells (DPCs) were isolated and cultured by one-step collagenase treatment. The DPC-Ba and DPC-Ca microcapsules were prepared by using a specially designed, high-voltage, electric-field droplet generator. Selected microcapsules were assessed for long-term inductive properties with xenotransplantation into Sprague-Dawley rat ears. Both barium and calcium microcapsules maintained xenogenic dermal papilla cells in an immunoisolated environment and induced the formation of hair follicle structures. Calcium microcapsules showed better biocompatibility, permeability, and cell viability in comparison with barium microcapsules. Before 18 weeks, calcium microcapsules gathered together, with no substantial immune response. After 32 weeks, some microcapsules were near inflammatory cells and wrapped with fiber. A few large hair follicles were found. Control samples showed no marked changes at the implantation site. Barium microcapsules were superior to calcium microcapsules in structural and mechanical stability. The cells encapsulated in hydrogel barium microcapsules exhibited higher short-term viability. This study established a model to culture DPCs in 3D culture conditions. Barium microcapsules may be useful in short-term transplantation study. Calcium microcapsules may provide an effective scaffold for the development of artificial dermal papilla. PMID:27123456

  12. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  13. Radiographer reporting in the UK: A longitudinal analysis

    International Nuclear Information System (INIS)

    Introduction: Radiographer reporting of plain film radiographs is an established role in the UK. Despite this previous research has demonstrated widespread inconsistencies in implementation, scope and utilisation. Method: A cross-sectional postal survey was undertaken to provide a longitudinal insight into changes in radiographer reporting practice. The sample comprised all individual hospital sites in the UK, Channel Islands and Isle of Man with both a radiology and trauma service Results: A response rate of 63.7% (n = 325/510) was achieved. Reporting radiographers were in place at 179 sites (55.1%) but less likely to be employed at sites with a minor injury unit rather than a full emergency department (χ2 = 71.983; p < 0.001; d.f. = 1). Radiographer utilisation has increased since 2007, although local barriers to implementation and activity were identified. Geographical variation was evident in relation to reporter employment and anatomical scope. A significant association was noted between broader anatomical scope and a wider range of referral sources (χ2 = 34.441; p < 0.001; d.f. = 1). Delayed reporting of radiographs remains the standard service delivery model across the UK. Conclusion: This study confirms the significant contribution that radiographers are making to reporting capacity in the UK, although there continue to be geographical variations, particularly around anatomical scope and referral groups. - Highlights: • Reporting radiographers are employed at 55.1% of responding hospitals. • There is geographic variation in roles and their scope. • A broader anatomical scope of reporting is linked to being able to report referrals from a wider range of sources. • Delayed reporting of radiographs remains the standard service delivery model

  14. The radiographic appearance of pulmonary histoplasmosis in the cat

    International Nuclear Information System (INIS)

    A retrospective study of 18 cats with pulmonary histoplasmosis was conducted to evaluate radiographic patterns of disease and to determine age, breed, and sex distributions. All cats had active disease confirmed by biopsy/aspiration cytology (lung, bone marrow, peripheral lymph nodes, pleural fluid) or necropsy examination. Cats 3 years of age or less had the highest incidence of disease; females outnumbered males 2 to 1. Radiographically, most cats had an interstitial pattern which appeared as a fine, diffuse or linear pattern, or as a more distinct nodular pattern. An alveolar pattern was an uncommon radiographic finding. Tracheobronchial lymphadenopathy and calcified lymph nodes or pulmonary parenchymal lesions were not identified in these cats

  15. Retrospective assessment of thoracic radiographic findings in metastatic canine hemangiosarcoma

    International Nuclear Information System (INIS)

    Twenty-one dogs with histopathologically confirmed hemangiosarcoma were evaluated by thoracic radiography for metastatic disease. All dogs had histopathologic examinations of the lungs within two weeks of thoracic radiography. Fourteen dogs had histopathologic evidence of pulmonary hemangiosarcoma; metastatic disease was detected radiographically in eleven of these dogs. The most common radiographic pattern was that of poorly defined small coalescing nodules (8 dogs); other radiographic patterns included well-circumscribed nodules (3 dogs) and alveolar infiltrates secondary to hemorrhage (2 dogs). Differential diagnoses for diffuse, poorly defined, coalescing pulmonary opacities should include hemangiosarcoma in addition to edema, lymphoma, systemic mycoses, fibrosis, allergy, toxicosis, and carcinomas

  16. Radiographic imaging of otitis media and interna in pigs

    International Nuclear Information System (INIS)

    Middle and inner ear infections have been reported as a clinical entity in swine, other animal species and humans. In pigs, the anatomical-pathological and microbiological findings have been described. In this report, we describe radiographic findings in affected pigs. A total of 25 pigs with a head tilt and circling, as clinical signs of otitis media and interna, were examined. The majority were weaner-pigs with dyspnea or rhinitis. In radiographs, there was an increased opacity of the bulla tympanica, often accompanied by marginal destruction or thickening of the bulla wall. The radiographic findings confirmed the clinical diagnosis in each affected pig, but there were 5 false positive interpretations

  17. The significance of radiographic magnification for modern diagnostic imaging methods

    International Nuclear Information System (INIS)

    Direct radiographic magnification is a well-established technique. Improved equipment recently has even enhanced its versatility and applicability to many general clinical problems. In our department, the radiographic magnification is not a 'special take', but is part of a usual radiographic examination and can be done with any X-ray equipment. The article explains the current equipment of the department and the techniques applied, also illustrating the broad applicability spectrum, including radiography of the pelvic region and of the lumbar spine. (orig.)

  18. Analysis of hand radiographs with neural network approach

    International Nuclear Information System (INIS)

    Early radiographic detection of osseous abnormalities is important for diagnosis of conditions such as osteoporosis, arthritis, or renal osteodystrophy due to hyperparathyroidism. The authors of this paper are developing computerized methods to analyze the degree of severity of these abnormalities seen in hand radiographs. The hand radiographs are digitized with a high-resolution laser digitizer to maintain the fine features of early osseous changes. To perform the analysis efficiently and automatically, they employ a two step approach. A data-compression technique is first applied to the image, and a neural network identifies the region of interest (ROI) on the compressed image

  19. X-ray equipment for student radiographers. 3. ed.

    International Nuclear Information System (INIS)

    The third edition of the book ''X-ray Equipment for Student Radiographers'' includes an extensive revision and updating to reflect the continued development of radiography equipment. The subject headings considered are the electrical system and mains supply, the components and controls in X-ray circuits, high tension generators, fuses, switches, interlocks, exposure switches and timers, logics, X-ray tubes, the control of scattered radiation, portable and mobile X-ray equipment, fluoroscopy, image intensifiers, fluoroscopic/radiographic tables, equipment for rapid serial radiography, equipment for cranial and dental radiography, specialized radiographic systems and care, maintenance and performance tests. This third edition also includes consideration of tomographic equipment. (U.K.)

  20. Pneumothorax in the Supine Patient: Subtle Radiographic Signs.

    Science.gov (United States)

    Rierson, Davis; Bueno, Juliana

    2016-07-01

    Routine posteroanterior chest radiographs and computed tomography scans are more sensitive for detecting pneumothoraces than anteroposterior chest radiographs. However, supine chest radiographs are commonly performed as part of the initial and routine assessment of trauma and critically ill patients. Rates of occult pneumothorax can be as high as 50% and have a significant impact in the mortality of these patients; thus, a prompt diagnosis of this entity is important. This pictorial essay will illustrate the pleural anatomy, explain the distribution of air within the pleural space in the supine position, and review the radiologic findings that characterize this entity. PMID:27105051