WorldWideScience

Sample records for bangerter occlusion foils

  1. The effect of Bangerter filters on binocular function in observers with amblyopia.

    Science.gov (United States)

    Chen, Zidong; Li, Jinrong; Thompson, Benjamin; Deng, Daming; Yuan, Junpeng; Chan, Lily; Hess, Robert F; Yu, Minbin

    2014-10-28

    We assessed whether partial occlusion of the nonamblyopic eye with Bangerter filters can immediately reduce suppression and promote binocular summation of contrast in observers with amblyopia. In Experiment 1, suppression was measured for 22 observers (mean age, 20 years; range, 14-32 years; 10 females) with strabismic or anisometropic amblyopia and 10 controls using our previously established "balance point" protocol. Measurements were made at baseline and with 0.6-, 0.4-, and 0.2-strength Bangerter filters placed over the nonamblyopic/dominant eye. In Experiment 2, psychophysical measurements of contrast sensitivity were made under binocular and monocular viewing conditions for 25 observers with anisometropic amblyopia (mean age, 17 years; range, 11-28 years; 14 females) and 22 controls (mean age, 24 years; range, 22-27; 12 female). Measurements were made at baseline, and with 0.4- and 0.2-strength Bangerter filters placed over the nonamblyopic/dominant eye. Binocular summation ratios (BSRs) were calculated at baseline and with Bangerter filters in place. Experiment 1: Bangerter filters reduced suppression in observers with amblyopia and induced suppression in controls (P = 0.025). The 0.2-strength filter eliminated suppression in observers with amblyopia and this was not a visual acuity effect. Experiment 2: Bangerter filters were able to induce normal levels of binocular contrast summation in the group of observers with anisometropic amblyopia for a stimulus with a spatial frequency of 3 cycles per degree (cpd, P = 0.006). The filters reduced binocular summation in controls. Bangerter filters can immediately reduce suppression and promote binocular summation for mid/low spatial frequencies in observers with amblyopia. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  2. Portable acuity screening for any school: validation of patched HOTV with amblyopic patients and Bangerter normals.

    Science.gov (United States)

    Tsao Wu, Maya; Armitage, M Diane; Trujillo, Claire; Trujillo, Anna; Arnold, Laura E; Tsao Wu, Lauren; Arnold, Robert W

    2017-12-04

    We needed to validate and calibrate our portable acuity screening tools so amblyopia could be detected quickly and effectively at school entry. Spiral-bound flip cards and download pdf surround HOTV acuity test box with critical lines were combined with a matching card. Amblyopic patients performed critical line, then threshold acuity which was then compared to patched E-ETDRS acuity. 5 normal subjects wore Bangerter foil goggles to simulate blur for comparative validation. The 31 treated amblyopic eyes showed: logMAR HOTV = 0.97(logMAR E-ETDRS)-0.04 r2 = 0.88. All but two (6%) fell less than 2 lines difference. The five showed logMAR HOTV = 1.09 ((logMAR E-ETDRS) + .15 r2 = 0.63. The critical-line, test box was 98% efficient at screening within one line of 20/40. These tools reliably detected acuity in treated amblyopic patients and Bangerter blurred normal subjects. These free and affordable tools provide sensitive screening for amblyopia in children from public, private and home schools. Changing "pass" criteria to 4 out of 5 would improve sensitivity with somewhat slower testing for all students.

  3. Effect of thermocycling on the shear bond strength of different resins bonded to thermoplastic foil applied in occlusal splint therapy.

    Science.gov (United States)

    Wieckiewicz, Mieszko; Boening, Klaus W; Richter, Gert; Wieckiewicz, Wlodzimierz

    2015-04-01

    Temporomandibular disorders are a group of symptoms related to the impaired function of the temporomandibular joints and associated muscles. Occlusal splint therapy is a common treatment in the aforementioned syndrome. One of the methods of manufacturing occlusal splints is to place a polymer on thermoplastic foil. The aim of this study was to evaluate the shear bond strength of light- and self-cured resins bonded to thermoplastic foil dependent on artificial aging. Thirty cylinders composed of light-cured resin and 30 cylinders made of self-cured resin were attached to 60 rectangular thermoplastic plates. All specimens were divided into six groups. A control study was conducted for groups 1 and 2. The other preparation groups were subjected to thermocycling by setting appropriately 1000 cycles for groups 3 and 4 and 3000 cycles for groups 5 and 6 in distilled water. Bond strength was measured in a universal testing machine. The results were subjected to statistical analysis using the Mann-Whitney U test (p ≤ 0.05). The statistics revealed that the values of the shear bond strength for specimens composed of self-cured resin after 1000 and 3000 thermocycles were significantly higher than on those made of light-cured resin (p = 0.003 and p = 0.002). The shear bond strength between the self-cured resin and the thermoplastic foil was higher and more resistant to aging than the shear bond strength between the light-cured resin and the thermoplastic foil. © 2014 by the American College of Prosthodontists.

  4. The use of choline in association with the Bangerter filters for the treatment of amblyopia

    Directory of Open Access Journals (Sweden)

    Lelio Sabetti

    2017-11-01

    Full Text Available The study investigated the effects of choline combined with Bangerter filter in the treatment of amblyopia. All amblyopic subjects used a Bangerter filter on the corrective spectacle lens (1d over the left eye, 1d over the right eye. Choline was then administered orally to 39 patients once daily, five days per week for the entire study period. Subjects treated with the Bangerter filter showed a mean visual acuity of 0.27 logMAR; at 12mo of treatment, the mean visual acuity reached 0.09 logMAR. Patients treated with the Bangerter filter and citicoline showed a mean visual acuity of 0.35 logMAR; at 12mo of treatment, the mean visual acuity reached 0.01 logMAR. No significant changes in the angle of deviation were observed in both groups. Subjects in both forms of amblyopia therapies demonstrated an increase in visual acuity. However, these effects were markedly enhanced when coupled with the administration of choline. Findings suggest that the effects are particularly relevant in the more severe amblyopic cases.

  5. Foil Artists

    Science.gov (United States)

    Szekely, George

    2010-01-01

    Foil can be shaped into almost anything--it is the all-purpose material for children's art. Foil is a unique drawing surface. It reflects, distorts and plays with light and imagery as young artists draw over it. Foil permits quick impressions of a model or object to be sketched. Foil allows artists to track their drawing moves, seeing the action…

  6. Foil Electron Multiplier

    Science.gov (United States)

    Funsten, Herbert O.; Baldonado, Juan R.; Dors, Eric E.; Harper, Ronnie W.; Skoug, Ruth M.

    2006-03-28

    An apparatus for electron multiplication by transmission that is designed with at least one foil having a front side for receiving incident particles and a back side for transmitting secondary electrons that are produced from the incident particles transiting through the foil. The foil thickness enables the incident particles to travel through the foil and continue on to an anode or to a next foil in series with the first foil. The foil, or foils, and anode are contained within a supporting structure that is attached within an evacuated enclosure. An electrical power supply is connected to the foil, or foils, and the anode to provide an electrical field gradient effective to accelerate negatively charged incident particles and the generated secondary electrons through the foil, or foils, to the anode for collection.

  7. [Relationship between Occlusal Discomfort Syndrome and Occlusal Threshold].

    Science.gov (United States)

    Munakata, Motohiro; Ono, Yumie; Hayama, Rika; Kataoka, Kanako; Ikuta, Ryuhei; Tamaki, Katsushi

    2016-03-01

    Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.

  8. Oscillating foil propulsion

    OpenAIRE

    Hauge, Jacob

    2013-01-01

    Unsteady foil theory is discussed and applied on several cases of an oscillating foil. The oscillating foil is meant as a propulsion system for a platform supply vessel.Four case studies of foil oscillation have been performed. A thrust coefficient of 0.1 was achieved at an efficiency of 0.75. A thrust coefficient of minimum 0.184 is necessary to overcome the calm water resistance of the foil.Issues connected to coupled vessel-foil models are discussed.

  9. Occlusal stability.

    Science.gov (United States)

    Wiens, Jonathan P; Priebe, Jennifer W

    2014-01-01

    Occlusion is the foundation for clinical success in fixed, removable, and implant prosthodontic treatment. Understanding those principles is critical when restoring a patient's occlusion. Many philosophies, devices, and theories of occlusion have evolved based on anecdotal clinical observations and applied geometric perceptions. The literature has reported these classic and contemporary occlusal concepts. As evidence-based dentistry emerged, it championed scrutiny of previously held beliefs, resulting in the abandonment of many pragmatic, yet beneficial occlusal procedures. The impetus toward scientific discovery, whereby factual information might be universally applied in dental education and clinical practice, has renewed interest in occlusal studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Occlusion revisited.

    Science.gov (United States)

    Taner, Tulin

    2012-03-01

    The evaluation of occlusion is of utmost importance, when planning for dental and orthodontic treatment. The occlusal characteristics of normal occlusion change according to the dentoalveolar maturation stages. In primary dentition, flush terminal plane relationship of the second primary molars is desired for a normal molar relationship. In the early mixed dentition stage, cusp to cusp molar relationship is the normal occlusal feature, when posterior primary teeth are in place and leeway space is preserved.

  11. Foil Face Seal Testing

    Science.gov (United States)

    Munson, John

    2009-01-01

    In the seal literature you can find many attempts by various researchers to adapt film riding seals to the gas turbine engine. None have been successful, potential distortion of the sealing faces is the primary reason. There is a film riding device that does accommodate distortion and is in service in aircraft applications, namely the foil bearing. More specifically a foil thrust bearing. These are not intended to be seals, and they do not accommodate large axial movement between shaft & static structure. By combining the 2 a unique type of face seal has been created. It functions like a normal face seal. The foil thrust bearing replaces the normal primary sealing surface. The compliance of the foil bearing allows the foils to track distortion of the mating seal ring. The foil seal has several perceived advantages over existing hydrodynamic designs, enumerated in the chart. Materials and design methodology needed for this application already exist. Also the load capacity requirements for the foil bearing are low since it only needs to support itself and overcome friction forces at the antirotation keys.

  12. Monolithic exploding foil initiator

    Science.gov (United States)

    Welle, Eric J; Vianco, Paul T; Headley, Paul S; Jarrell, Jason A; Garrity, J. Emmett; Shelton, Keegan P; Marley, Stephen K

    2012-10-23

    A monolithic exploding foil initiator (EFI) or slapper detonator and the method for making the monolithic EFI wherein the exploding bridge and the dielectric from which the flyer will be generated are integrated directly onto the header. In some embodiments, the barrel is directly integrated directly onto the header.

  13. Process for anodizing aluminum foil

    International Nuclear Information System (INIS)

    Ball, J.A.; Scott, J.W.

    1984-01-01

    In an integrated process for the anodization of aluminum foil for electrolytic capacitors including the formation of a hydrous oxide layer on the foil prior to anodization and stabilization of the foil in alkaline borax baths during anodization, the foil is electrochemically anodized in an aqueous solution of boric acid and 2 to 50 ppm phosphate having a pH of 4.0 to 6.0. The anodization is interrupted for stabilization by passing the foil through a bath containing the borax solution having a pH of 8.5 to 9.5 and a temperature above 80 0 C. and then reanodizing the foil. The process is useful in anodizing foil to a voltage of up to 760 V

  14. Body position and occlusal contacts in lateral excursions: a pilot study

    NARCIS (Netherlands)

    Spijker, A. van 't; Creugers, N.H.J.; Bronkhorst, E.M.; Kreulen, C.M.

    2011-01-01

    This pilot study aimed to explore whether occlusal contacts during lateral excursions are influenced by tilted body positions. Occlusal contacts in lateral excursions were verified for 30 dental students and 22 dental staff members using articulation foil while patients were seated in a dental

  15. FOIL ELEMENT FOR NUCLEAR REACTOR

    Science.gov (United States)

    Noland, R.A.; Walker, D.E.; Spinrad, B.I.

    1963-07-16

    A method of making a foil-type fuel element is described. A foil of fuel metal is perforated in; regular design and sheets of cladding metal are placed on both sides. The cladding metal sheets are then spot-welded to each other through the perforations, and the edges sealed. (AEC)

  16. Consequences of FOIL for Undergraduates

    Science.gov (United States)

    Koban, Lori; Sisneros-Thiry, Simone

    2015-01-01

    FOIL is a well-known mnemonic that is used to find the product of two binomials. We conduct a large sample (n = 252) observational study of first-year college students and show that while the FOIL procedure leads to the accurate expansion of the product of two binomials for most students who apply it, only half of these students exhibit conceptual…

  17. Foil-to-foil system integration through capillary self-alignment directed by laser patterning

    OpenAIRE

    Arutinov, G Gari; Mastrangeli, M; Smits, ECP Edsger; Heck, van, G; Toonder, den, JMJ Jaap; Dietzel, AH Andreas

    2015-01-01

    This paper introduces a new integration technology for cost-effective high-precision mechanical and electrical integration of mesoscopic functional foil components onto foil substrates. The foil-to-foil assembly process is based on topological surface structuring via laser patterning that enables accurate capillarity-driven self-alignment of foil dies. The concurrent establishment of high-yield electrical interconnections is obtained through conductive adhesives. The foil surface energy contr...

  18. Post-foil interaction in foil-induced molecular dissociation

    International Nuclear Information System (INIS)

    Faibis, A.; Kanter, E.P.; Koenig, W.; Plesser, I.; Vager, Z.

    1985-01-01

    The authors have investigated the foil-induced dissociation of 175- 250- keV/amu CH + , NH + , and OH + , FH + and NeH + ions by coincident detection of the fragment atoms. The dissociation energies corresponding to in-foil and post-foil interactions were deduced from the measured relative flight times of the fragment pairs to a set of detectors downstream from the target. The authors considered final states consisting of a) a proton and a heavy-ion and, b) a hydrogen atom and a heavy-ion. Surprisingly, in both cases the energy released in the post-target interaction shows a similar linear increase with the charge state of the heavy partner

  19. Numerical and experimental investigation of bump foil mechanical behaviour

    DEFF Research Database (Denmark)

    Larsen, Jon Steffen; Cerda Varela, Alejandro Javier; Santos, Ilmar

    2014-01-01

    Corrugated foils are utilized in air foil bearings to introduce compliance and damping thus accurate mathematical predictions are important. A corrugated foil behaviour is investigated experimentally as well as theoretically. The experimental investigation is performed by compressing the foil...

  20. kFOIL: Learning simple relational kernels

    OpenAIRE

    Landwehr, Niels; Passerini, Andrea; De Raedt, Luc; Frasconi, Paolo

    2006-01-01

    A novel and simple combination of inductive logic programming with kernel methods is presented. The kFOIL algorithm integrates the well-known inductive logic programming system FOIL with kernel methods. The feature space is constructed by leveraging FOIL search for a set of relevant clauses. The search is driven by the performance obtained by a support vector machine based on the resulting kernel. In this way, kFOIL implements a dynamic propositionalization approach. Both classification an...

  1. Foil-to-Foil system integration through capillary self-alignment directed by laser patterning

    NARCIS (Netherlands)

    Arutinov, G.; Mastrangeli, M.; Smits, E.C.P.; Heck, G. van; Toonder, J.M.J. den; Dietzel, A.H.

    2014-01-01

    This paper introduces a new integration technology for cost-effective high-precision mechanical and electrical integration of mesoscopic functional foil components onto foil substrates. The foil-to-foil assembly process is based on topological surface structuring via laser patterning that enables

  2. Passive Thermal Management of Foil Bearings

    Science.gov (United States)

    Bruckner, Robert J. (Inventor)

    2015-01-01

    Systems and methods for passive thermal management of foil bearing systems are disclosed herein. The flow of the hydrodynamic film across the surface of bearing compliant foils may be disrupted to provide passive cooling and to improve the performance and reliability of the foil bearing system.

  3. Development of a new foil positioning mechanism

    International Nuclear Information System (INIS)

    Ansari, Q.N.; Bhagwat, P.V.; Gupta, A.K.; Choudhury, R.K.

    2009-01-01

    In a tandem accelerator, negative ions are accelerated to high voltage terminal where beam pass through a foil stripper/gas stripper or combination of both, ultimately positive ions accelerated. The optimum thickness of stripper foil is in the range of 3-5 μg/cm 2 for 14 MeV ion beam. A new foil changing system for Pelletron Accelerator has been developed based on micro-stepping stepper motor arrangement. Present Geneva based mechanism is driven by the AC motor using belt and pulley, which rotates by 90° for each revolution of motor shaft and brings the foil in position with beam axis. The belt carries 200 foils and due to prolonged usage and subsequent slackness of the belt, the foil position is not reproducible. Also, it is found that sometimes foil position is proper either in increase or in decrease mode. There is no provision to adjust foil position with respect to beam axis in the current mechanism. To overcome this problem a new stepper motor based system is under development which uses smooth rotation and fine positioning. Micro-controller chip used is programmed to control the rotation and select the foils in increase/decrease mode. In addition, a fine control is also provided to adjust the angular position of foil to avail optimum transmission. This paper presents the salient features of the foil positioning mechanism. (author)

  4. Zika Vaccine Development: Flavivirus Foils

    Science.gov (United States)

    2016-09-01

    Martins, Bavari, Zika Vaccine Development 1 Zika Vaccine Development: Flavivirus Foils Martins KAO, Bavari S. The current Zika virus...contrast, work had been underway for decades on the development of an Ebola virus vaccine , laying the groundwork for a rapid response in 2014. The...broader community’s extensive experience with Dengue virus vaccine development and with the pros and cons of different vaccine platforms has led to

  5. Technical Development Path for Gas Foil Bearings

    Science.gov (United States)

    Dellacorte, Christopher

    2016-01-01

    Foil gas bearings are in widespread commercial use in air cycle machines, turbocompressors and microturbine generators and are emerging in more challenging applications such as turbochargers, auxiliary power units and propulsion gas turbines. Though not well known, foil bearing technology is well over fifty years old. Recent technological developments indicate that their full potential has yet to be realized. This paper investigates the key technological developments that have characterized foil bearing advances. It is expected that a better understanding of foil gas bearing development path will aid in future development and progress towards more advanced applications.

  6. Performance Analysis of Gas Foil Bearing with Different Foil Pivot Configuration

    OpenAIRE

    Milind Babasaheb Patil; Karuna Kalita; Sashindra K. Kakoty

    2013-01-01

    A numerical model is developed in order to find out the performance characteristics of gas foil bearings. The static performance analysis of gas foil bearings has been carried out using an elastic foundation model of the foil. The steady state results have been compared with the experimental and theoretical results available in the literature. The characteristics of the bearing have been investigated with change in foil pivot position. It has been shown that the load carrying capacity is diff...

  7. Radiation lifetimes and failure mechanisms of carbon stripper foils

    International Nuclear Information System (INIS)

    Auble, R.L.

    1981-01-01

    Measurements of lifetimes of thin carbon foils under heavy-ion irradiation are compiled and recent advances in stripper foil technology are reviewed. The impact of recent foil lifetime improvements, many by more than an order of magnitude, on heavy-ion electrostatic accelerators is discussed. Foil inhomogeneities, particularly those caused by sputtering are suggested to be a prime factor in usable foil lifetimes

  8. Occlusion effects, Part I

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    annoyances and the objective measurements were analysed. Persons suffering from tinnitus behaved differently than person without tinnitus. The latter group showed significant relations between the measured occlusion effect, hearing loss and the personal of occlusion. The actual sensation level is also...

  9. Viewpoint-based ambient occlusion.

    Science.gov (United States)

    González, Francisco; Sbert, Mateu; Feixas, Miquel

    2008-01-01

    A new ambient occlusion technique builds a channel between various viewpoints and an object's polygons, providing the information needed to create an occlusion map with multiple application possibilities.

  10. A metal-lustrous porphyrin foil.

    Science.gov (United States)

    Morisue, Mitsuhiko; Hoshino, Yuki; Shimizu, Masaki; Tomita, Shogo; Sasaki, Sono; Sakurai, Shinichi; Hikima, Takaaki; Kawamura, Ayaka; Kohri, Michinari; Matsui, Jun; Yamao, Takeshi

    2017-09-26

    A metal-lustrous self-standing film, named "porphyrin foil", was formed from a glass-forming polymeric porphyrin. The amorphous glass nature of the porphyrin foil played a key role in spontaneously producing a smooth surface. Its sharp contrast in intense absorption and specular reflection of light at each wavelength provided a brilliant metallic lustre.

  11. Dress Images on Gold-foil Figures

    DEFF Research Database (Denmark)

    Mannering, Ulla; Andersson Strand, Eva Birgitta

    2009-01-01

    From the Late Iron Age settlement Sorte Muld on Bornholm both gold foil figures with depictions of costumes and textile tools can tell about textile production.......From the Late Iron Age settlement Sorte Muld on Bornholm both gold foil figures with depictions of costumes and textile tools can tell about textile production....

  12. Vertebrobasilar Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Schoen, Jessica

    2011-05-01

    Full Text Available The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. [West J Emerg Med. 2011;12(2:233-239.

  13. Circuit design on plastic foils

    CERN Document Server

    Raiteri, Daniele; Roermund, Arthur H M

    2015-01-01

    This book illustrates a variety of circuit designs on plastic foils and provides all the information needed to undertake successful designs in large-area electronics.  The authors demonstrate architectural, circuit, layout, and device solutions and explain the reasons and the creative process behind each. Readers will learn how to keep under control large-area technologies and achieve robust, reliable circuit designs that can face the challenges imposed by low-cost low-temperature high-throughput manufacturing.   • Discusses implications of problems associated with large-area electronics and compares them to standard silicon; • Provides the basis for understanding physics and modeling of disordered material; • Includes guidelines to quickly setup the basic CAD tools enabling efficient and reliable designs; • Illustrates practical solutions to cope with hard/soft faults, variability, mismatch, aging and bias stress at architecture, circuit, layout, and device levels.

  14. An alternative treatment of occlusal wear: Cast metal occlusal surface

    OpenAIRE

    Sandeep Kumar; Aman Arora; Reena Yadav

    2012-01-01

    Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal sur...

  15. Occlusive Peripheral Arterial Disease

    Science.gov (United States)

    ... Lower Your Stroke Risk? Ecstasy May Help Some PTSD Sufferers, but Safety Issues Remain First Death Reported ... of these factors contributes not only to the development of occlusive peripheral arterial disease but also to ...

  16. Occlusion effects, Part II

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    The present report studies the mechanism of the occlusion effect by means of literature studies, experiments and model estimates. A mathematical model of the occlusion effect is developed. The model includes the mechanical properties of the earmould and the airborne sound as well as the body...... conducted sound from own voice. These aspects are new in the sense that previous studies disregard the earmould mechanics and includes only one sound source placed in the ear canal....

  17. Hyaluronan-lecithin foils and their properties

    Energy Technology Data Exchange (ETDEWEB)

    BiaIopiotrowicz, Tomasz [Department of Interfacial Phenomena, Faculty of Chemistry, Maria Curie-SkIodowska University, Maria Curie-SkIodowska Square 3, 20-031 Lublin (Poland); Janczuk, BronisIaw [Department of Interfacial Phenomena, Faculty of Chemistry, Maria Curie-SkIodowska University, Maria Curie-SkIodowska Square 3, 20-031 Lublin (Poland); Fiedorowicz, Maciej [Department of Chemistry, Agricultural University of Krakow, Mickiewicz Ave., 21, 31 120 Cracow (Poland); Khachatryan, Gohar [Department of Chemistry, Agricultural University of Krakow, Mickiewicz Ave., 21, 31 120 Cracow (Poland); Tomasik, Piotr [Department of Chemistry, Agricultural University of Krakow, Mickiewicz Ave., 21, 31 120 Cracow (Poland)]. E-mail: rrtomasi@cyf-kr.edu.pl; Bakos, Dusan [Faculty of Chemical and Food Technology, Slovak Technical University, Radlinskeho 9, 812 37 Bratislava (Slovakia)

    2006-01-10

    Thin, elastic foils of good resistance to the air exposure, patented as wound healing aids, were prepared by evaporation of a blend of lecithin (L) and sodium hyaluronan (H) taken under varying proportions. The contact angle for water, glycerol, formamide, ethylene glycol and diiodomethane, was determined for these foils. The contact angle was correlated against the H:L foil composition. For all liquids but formamide the highest contact angle was noted for the H:L = 2:1 (g g{sup -1}) ratio. The contact angles provided estimation of the work of adhesion. At the same L:H ratio the work of adhesion was the lowest. It was suggested that lecithin cross-linked hyaluronan. Since the work of adhesion of the studied liquids was similar to that of diiodomethane, it could be concluded that almost all functional groups on the foil surface were completely blocked. Perhaps, at H:L = 2:1 (g g{sup -1}) a stoichiometric complex of hyaluronic acid with lecithin was formed, and polar functional groups from both reagents were involved. Foils seem to be electrostatic complexes of H with L. Foils with the H:L equal to 2:1 exhibited specific properties confirmed by the IR reflectance spectra of the foils. The thermogravimetry (TG/DTG) also revealed unique thermal behaviour confirming other specific properties of the foil of this composition. For the same ratio a thorough inspection of the scanning electron micrographs (SEM) revealed few irregularly distributed perforations of 1-2 {mu}m in diameter seen as black points, which can be recognized as pores. Properties of the foils determined in the contact angle measurements are nicely backed by the results from thermogravimetric and scanning electron microscopic studies.

  18. Analysis of Mechanical Properties for GEM Foil

    CERN Document Server

    Chin, Yuk Ming

    2016-01-01

    In view of new assembly technique of the GEM detector; in which three foils stack is stretched to get the uniform gaps among the foils. We studied the mechanical properties of the foil material. We conditioned the samples in different environments to make them extra dry and wet. As holes are the major source of the charge amplification their deformation can effect the detector performance. Therefore in our studies we also studied at which level of the stress the holes deformation is seen. These tensile and holes deformation studies can help to optimize the stress during detector assembly.

  19. Bonded Invar Clip Removal Using Foil Heaters

    Science.gov (United States)

    Pontius, James T.; Tuttle, James G.

    2009-01-01

    A new process uses local heating and temperature monitoring to soften the adhesive under Invar clips enough that they can be removed without damaging the composite underneath or other nearby bonds. Two 1x1 in. (approx.2.5x2.5 cm), 10-W/sq in. (approx.1.6-W/sq cm), 80-ohm resistive foil Kapton foil heaters, with pressure-sensitive acrylic adhesive backing, are wired in parallel to a 50-V, 1-A limited power supply. At 1 A, 40 W are applied to the heater pair. The temperature is monitored in the clip radius and inside the tube, using a dual thermocouple readout. Several layers of aluminum foil are used to speed the heat up, allowing clips to be removed in less than five minutes. The very local heating via the foil heaters allows good access for clip removal and protects all underlying and adjacent materials.

  20. Radioactivity analysis in niobium activation foils

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, G.E.

    1995-06-01

    The motivation for this study was to measure and analyze the activity of six (6) niobium (Nb) foils (the x-rays from an internal transition in Nb-93m) and apply this information with previously obtained activation foil data. The niobium data was used to determine the epithermal to MeV range for the neutron spectrum and fluence. The foil activation data was re-evaluated in a spectrum analysis code (STAY`SL) to provide new estimates of the exposure at the Los Alamos Spallation Radiation Effect Facility (LASREF). The activity of the niobium foils was measured and analyzed at the University of Missouri-Columbia (UMC) under the direction of Professor William Miller. The spectrum analysis was performed at the University of Missouri-Rolla (UMR) by Professor Gary Mueller.

  1. Transient and steady state behaviour of elasto–aerodynamic air foil bearings, considering bump foil compliance and top foil inertia and flexibility: A numerical investigation

    DEFF Research Database (Denmark)

    Nielsen, Bo Bjerregaard; Santos, Ilmar F.

    2017-01-01

    This work gives a theoretical contribution to the problem of modelling air foil bearings considering large sagging effects in the calculation of the non-linear transient and steady state response of a rigid rotor. This paper consists of two parts: the development of a miltiphysics model of the air...... foils and one air foil bearing with a fully supported top foil. The steady state responses of a journal supported by these air foil bearings are investigated for varied rotational speeds and journal unbalances as well as the top foil sagging in the unsupported area. The study reveals that sub...

  2. [Complete denture occlusion considered from occlusal contacts during mastication].

    Science.gov (United States)

    Suzuki, Tetsuya

    2004-12-01

    Few reports describe the functional superiority of full balanced occlusion to that of lingualized occlusion. Recently, a bilateral balanced scheme has been much more generally applied than a unilateral balanced scheme in lingualized occlusion as well as in full balanced occlusion. Occlusal contacts on the non-chewing side occur earlier than on the chewing side;in the order of second molar, first molar, and then premolars. The contact on the balancing side contributes to the prevention of denture dislocation and guidance from eccentric positions to the centric occlusal position during mastication. Therefore, bilateral balanced occlusion was shown to be effective for denture stability during mastication with complete dentures. Today's typical edentulous patients have greater mean age than in the past, and thus are seen with severe alveolar bone resorption, thin mucosa and sometimes abnormalities of the maxillomandibular relation. Their occlusal positions are often unstable and changeable after insertion of complete dentures. Because lingualized occlusion allows for easier accommodation and correction, lingualized occlusion is more suitable for such cases than full balanced occlusion, which requires a strict occlusal relationship. In light of the standard Japanese diet, there is some doubt about why lingualized occlusion might be suitable for Japanese edentulous patients in terms of the sense of mastication. A method of evaluating the sense of mastication needs to be established.

  3. Capillary self-alignment of mesoscopic foil components for sensor-systems-in-foil

    NARCIS (Netherlands)

    Arutinov, G.; Smits, E.C.P.; Mastrangeli, M.; Heck, G. van; Brand, J. van den; Schoo, H.F.M.; Dietzel, A.H.

    2012-01-01

    This paper reports on the effective use of capillary self-alignment for low-cost and time-efficient assembly of heterogeneous foil components into a smart electronic identification label. Particularly, we demonstrate the accurate (better than 50m) alignment of cm-sized functional foil dies. We

  4. Foil-to-foil lamination and electrical interconnection of printed components on flexible substrates

    NARCIS (Netherlands)

    Vásquez Quintero, A.; Remoortere, B. van; Smits, E.C.P.; Brand, J. van den; Briand, D.; Schoo, H.F.M.; Rooij, N.F. de

    2013-01-01

    This paper describes and compares two integration methods to structurally laminate and interconnect foil-based components with flexible polymeric substrates. The first method uses isotropic conductive adhesives (ICA) confined in laser-ablated through foil vias (TFV), while the second one uses an

  5. Occlusal vertical dimension. Review article

    OpenAIRE

    Alvítez Temoche, Daniel Augusto; Facultad de Odontología de la Universidad Nacional Mayor de San Marcos.

    2016-01-01

    Modication of occlusal vertical dimension is a procedure that is often necessary for complex oral reha-bilitation treatments to get a functional occlusal for patients. is literature review was made on databases: Medline (PubMed), Scopus, Scielo, BSV (Bireme), ISI (Web of science) and Lilacs using the keywords “occlusal vertical dimension”,”altered vertical dimension”, “temporomandibular joint”, and “masticatory muscles”. It can be said that the management of occlusal vertical dimension is a s...

  6. Balanced (C_7, C_8)-Foil Designs and Related Designs

    OpenAIRE

    USHIO, Kazuhiko

    2011-01-01

    [Abstract] In graph theory, the decomposition problem of graphs is a very important topic. Various type of decompositions of many graphs can be seen in the literature of graph theory. This paper gives balanced (C_7, C_8)-foil designs, balanced C_15-foil designs, balanced (C_〈14〉, C_〈16〉)-foil designs, balanced C_〈30〉-foil designs, balanced C_45-foil designs, balanced C_〈60〉-foil designs, balanced C_〈75〉-foil designs, balanced C_〈90〉-foil designs, balanced C_〈105〉-foil designs, balanced C_〈120...

  7. Additional security features for optically variable foils

    Science.gov (United States)

    Marshall, Allan C.; Russo, Frank

    1998-04-01

    For thousands of years, man has exploited the attraction and radiance of pure gold to adorn articles of great significance. Today, designers decorate packaging with metallic gold foils to maintain the prestige of luxury items such as perfumes, chocolates, wine and whisky, and to add visible appeal and value to wide range of products. However, today's products do not call for the hand beaten gold leaf of the Ancient Egyptians, instead a rapid production technology exists which makes use of accurately coated thin polymer films and vacuum deposited metallic layers. Stamping Foils Technology is highly versatile since several different layers may be combined into one product, each providing a different function. Not only can a foil bring visual appeal to an article, it can provide physical and chemical resistance properties and also protect an article from human forms of interference, such as counterfeiting, copying or tampering. Stamping foils have proved to be a highly effective vehicle for applying optical devices to items requiring this type of protection. Credit cards, bank notes, personal identification documents and more recently high value packaged items such as software and perfumes are protected by optically variable devices applied using stamping foil technology.

  8. Lifetime measurements on carbon stripper foils

    International Nuclear Information System (INIS)

    Auble, R.L.; Galbraith, D.M.

    1981-01-01

    One of the most exciting recent developments in accelerator technology is the new breed of electrostatic accelerators. These machines have terminal potentials of 25 million volts and higher and are being built to accelerate intense beams of heavy ions. One such accelerator is now nearing completion at ORNL. A crucial component in these--as in any electrostatic accelerator--is a tiny bit of carbon in the form of a very thin foil. These foils, called stripper foils, are used to strip electrons from atoms so that they will be accelerated to high energy by the electrostatic potential. While carbon foils are not the only method of stripping electrons, they have a number of advantages over the alternative gas strippers. In particular, they produce higher charge states which are essential for providing the energetic ions required for heavy ion physics experiments. Because of the importance of stripper foils to the most efficient operation of the new ORNL accelerator, we are quite interested in their properties and in improving their performance

  9. Cryostat with Foil and MLI

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Peter K.F.; Gung, Chen-yu

    2005-10-06

    Induction cores are used to accelerate heavy ion beam array, which are built around the outer diameter of the cryostat housing the superconducting quadruple array. Compact cryostat is highly desirable to reduce the cost of the induction cores. Recent experiences in fabrication of a cryostat for single beam transport revealed that it is possible to reduce the spacing in the cryostat vacuum jacket by using low-emissivity thermal insulation material instead of conventional MLI. However, it is labor-intensive to install the new type of insulation as compared with using MLI. It is promising to build a cost-effective compact cryostat for quadruple magnet array for heavy ion beam array transport by using low-emissivity material combined with conventional MLI as radiation insulation. A matrix of insulation designs and tests will be performed as the feasibility study and for the selection of the optimal thermal insulation as the Phase I work. The selected mixed insulation will be used to build prototype compact cryostats in the Phase II project, which are aiming for housing quadruple doublet array. In this STTR phase I study, a small cryostat has been designed and built to perform calorimetric characterization of the heat load in a liquid helium vessel insulated with a vacuum layer with a nominal clearance of 3.5 mm. The vacuum clearance resembled that used in the warm-bore beam tube region in a prototype cryostat previously built for the heavy ion beam transport experiment. The vacuum clearance was geometrically restricted with a heater shell with the temperature controlled at near 300 K. Various combinations of radiation and thermal shields were installed in the tight vacuum clearance for heat load measurements. The measured heat loads are reported and compared with previous test result using a compact vacuum layer. Further developments of the thermal insulations used in the present study are discussed. The compact cryostat with foil and MLI insulation may be used in the

  10. Optofluidic dye laser in a foil

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Christiansen, Mads Brøkner; Mappes, Timo

    2010-01-01

    First order distributed feedback optofluidic dye lasers embedded in a 350 mu m thick TOPAS (R) foil are demonstrated. They are designed in order to give high output pulse energies. Microfluidic channels and first order distributed feedback gratings are fabricated in parallel by thermal nanoimprint...... into a 100 mu m foil. The channels are closed by thermal bonding with a 250 mu m thick foil and filled with 5.10(-3) mol/l Pyrromethene 597 in benzyl alcohol. The fluid forms a liquid core single mode slab waveguide of 1.6 mu m height on a nanostructured grating area of 0.5 x 0.5 mm(2). This results...

  11. Calculation of electron transmission through aluminium foil

    International Nuclear Information System (INIS)

    Abroyan, M.A.; Mel'ker, A.I.; Mikhajlin, A.I.; Sirotinkin, V.V.; Tokmakov, I.L.

    1987-01-01

    Calculated by Monte Carlo method energy and angular distributions of electrons transmitted through aluminium foil with 50 μm thickness are presented. 200-500 electron energy ranges and angles of electron incidence on foil from 0 to 40 deg C are considered. That allows to use results for more universal accelerator group, for example, for accelerators with scanning beam used in industry. The received values of angular and energy characteristics allow to increase essentially estimation accuracy of accelerator extraction devices and dose distribution on irradiating item

  12. Compressor ported shroud for foil bearing cooling

    Science.gov (United States)

    Elpern, David G [Los Angeles, CA; McCabe, Niall [Torrance, CA; Gee, Mark [South Pasadena, CA

    2011-08-02

    A compressor ported shroud takes compressed air from the shroud of the compressor before it is completely compressed and delivers it to foil bearings. The compressed air has a lower pressure and temperature than compressed outlet air. The lower temperature of the air means that less air needs to be bled off from the compressor to cool the foil bearings. This increases the overall system efficiency due to the reduced mass flow requirements of the lower temperature air. By taking the air at a lower pressure, less work is lost compressing the bearing cooling air.

  13. Spallation Neutron Source SNS Diamond Stripper Foil Development

    International Nuclear Information System (INIS)

    Shaw, Robert W.; Plum, Michael A.; Wilson, Leslie L.; Feigerle, Charles S.; Borden, Michael J.; Irie, Y.; Sugai, I.; Takagi, A.

    2007-01-01

    Diamond stripping foils are under development for the SNS. Freestanding, flat 300 to 500 (micro)g/cm 2 foils as large as 17 x 25 mm 2 have been prepared. These nano-textured polycrystalline foils are grown by microwave plasma-assisted chemical vapor deposition in a corrugated format to maintain their flatness. They are mechanically supported on a single edge by a residual portion of their silicon growth substrate; fine foil supporting wires are not required for diamond foils. Six foils were mounted on the SNS foil changer in early 2006 and have performed well in commissioning experiments at reduced operating power. A diamond foil was used during a recent experiment where 15 (micro)C of protons, approximately 64% of the design value, were stored in the ring. A few diamond foils have been tested at LANSCE/PSR, where one foil was in service for a period of five months (820 C of integrated injected charge) before it was replaced. Diamond foils have also been tested in Japan at KEK (640 keV H - ) where their lifetimes slightly surpassed those of evaporated carbon foils, but fell short of those for Sugai's new hybrid boron carbon (HBC) foils.

  14. Left atrial appendage occlusion

    Directory of Open Access Journals (Sweden)

    Ahmad Mirdamadi

    2013-01-01

    Full Text Available Left atrial appendage (LAA occlusion is a treatment strategy to prevent blood clot formation in atrial appendage. Although, LAA occlusion usually was done by catheter-based techniques, especially percutaneous trans-luminal mitral commissurotomy (PTMC, it can be done during closed and open mitral valve commissurotomy (CMVC, OMVC and mitral valve replacement (MVR too. Nowadays, PTMC is performed as an optimal management of severe mitral stenosis (MS and many patients currently are treated by PTMC instead of previous surgical methods. One of the most important contraindications of PTMC is presence of clot in LAA. So, each patient who suffers of severe MS is evaluated by Trans-Esophageal Echocardiogram to rule out thrombus in LAA before PTMC. At open heart surgery, replacement of the mitral valve was performed for 49-year-old woman. Also, left atrial appendage occlusion was done during surgery. Immediately after surgery, echocardiography demonstrates an echo imitated the presence of a thrombus in left atrial appendage area, although there was not any evidence of thrombus in pre-pump TEE. We can conclude from this case report that when we suspect of thrombus of left atrial, we should obtain exact history of previous surgery of mitral valve to avoid misdiagnosis clotted LAA, instead of obliterated LAA. Consequently, it can prevent additional evaluations and treatments such as oral anticoagulation and exclusion or postponing surgeries including PTMC.

  15. Examination of the picture properties of luminescence memory foils

    International Nuclear Information System (INIS)

    Ewert, U.; Heine, S.; Nockemann, C.; Stade, J.; Tillack, G.R.; Wessel, H.; Zscherpel, U.; Mattis, A.

    1995-01-01

    Luminescence memory foils are a new medium for radiography without films. They are known by the name of image plates or digital memory foils. The suitability of such systems for industrial radiography is examined. (orig.) [de

  16. LENA Conversion Foils Using Single-Layer Graphene, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Our key innovation will be the use of single-layer graphene as LENA conversion foils, with appropriate microgrids and nanogrids to support the foils. Phase I...

  17. An alternative treatment of occlusal wear: cast metal occlusal surface.

    Science.gov (United States)

    Kumar, Sandeep; Arora, Aman; Yadav, Reena

    2012-01-01

    Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal surfaces, however, these methods are time-consuming, expensive and requires many cumbersome steps. These methods also requires the patient to be without the prosthesis for the time during which the laboratory procedures are performed. This article presents a quick, simple and relatively inexpensive procedure for construction of metal occlusal surfaces on complete dentures.

  18. An alternative treatment of occlusal wear: Cast metal occlusal surface

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar

    2012-01-01

    Full Text Available Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal surfaces, however, these methods are time-consuming, expensive and requires many cumbersome steps. These methods also requires the patient to be without the prosthesis for the time during which the laboratory procedures are performed. This article presents a quick, simple and relatively inexpensive procedure for construction of metal occlusal surfaces on complete dentures.

  19. Hydrogen and Palladium Foil: Two Classroom Demonstrations

    Science.gov (United States)

    Klotz, Elsbeth; Mattson, Bruce

    2009-01-01

    In these two classroom demonstrations, students observe the reaction between H[subscript 2] gas and Pd foil. In the first demonstration, hydrogen and palladium combine within one minute at 1 atm and room temperature to yield the non-stoichiometric, interstitial hydride with formula close to the maximum known value, PdH[subscript 0.7]. In the…

  20. 6Li foil thermal neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, Kiril D [Los Alamos National Laboratory; Swinhoe, Martyn T [Los Alamos National Laboratory; Favalli, Andrea [Los Alamos National Laboratory; Chung, Kiwhan [Los Alamos National Laboratory; Macarthur, Duncan W [Los Alamos National Laboratory

    2010-01-01

    In this paper we report on the design of a multilayer thermal neutron detector based on {sup 6}Li reactive foil and thin film plastic scintillators. The {sup 6}Li foils have about twice the intrinsic efficiency of {sup 10}B films and about four times higher light output due to a unique combination of high energy of reaction particles, low self absorption, and low ionization density of tritons. The design configuration provides for double sided readout of the lithium foil resulting in a doubling of the efficiency relative to a classical reactive film detector and generating a pulse height distribution with a valley between neutron and gamma signals similar to {sup 3}He tubes. The tens of microns thickness of plastic scintillator limits the energy deposited by gamma rays, which provides the necessary neutron/gamma discrimination. We used MCNPX to model a multilayer Li foil detector design and compared it with the standard HLNCC-II (18 {sup 3}He tubes operated at 4 atm). The preliminary results of the {sup 6}Li configuration show higher efficiency and one third of the die-away time. These properties, combined with the very short dead time of the plastic scintillator, offer the potential of a very high performance detector.

  1. The Fluid Foil: The Seventh Simple Machine

    Science.gov (United States)

    Mitts, Charles R.

    2012-01-01

    A simple machine does one of two things: create a mechanical advantage (lever) or change the direction of an applied force (pulley). Fluid foils are unique among simple machines because they not only change the direction of an applied force (wheel and axle); they convert fluid energy into mechanical energy (wind and Kaplan turbines) or vice versa,…

  2. Vortex wakes of a flapping foil

    DEFF Research Database (Denmark)

    Schnipper, Teis; Andersen, Anders Peter; Bohr, Tomas

    2009-01-01

    We present an experimental study of a symmetric foil performing pitching oscillations in a vertically flowing soap film. By varying the frequency and amplitude of the oscillation we visualize a variety of wakes with up to 46 vortices per oscillation period, including von Karman vortex street, inv...

  3. Thermal Sensitive Foils in Physics Experiments

    Science.gov (United States)

    Bochnícek, Zdenek; Konecný, Pavel

    2014-01-01

    The paper describes a set of physics demonstration experiments where thermal sensitive foils are used for the detection of the two dimensional distribution of temperature. The method is used for the demonstration of thermal conductivity, temperature change in adiabatic processes, distribution of electromagnetic radiation in a microwave oven and…

  4. Beam-foil study of neon in the EUV with foils of carbon, silver and gold

    International Nuclear Information System (INIS)

    Demarest, J.A.; Watson, R.L.; Texas A and M Univ., College Station

    1988-01-01

    A beam-foil study of 40 MeV neon was conducted in the EUV with a 1-meter grazing incidence spectrometer configured with a position sensitive microchannel plate detector. A number of new lines of Ne IX, mainly from transitions to n = 3 levels, were detected in the wavelength region covering 50-350 A. Comparison of the spectra obtained using the different foils revealed that the average charge state of the neon projectiles was nearly one unit higher with carbon than with either of the two metals. Measurements of line intensities versus distance from the foils showed that cascade contributions were greatly reduced for the metals. It was also found that n = 3 states of low l were overpopulated relative to a statistical distribution, irrespective of the foil material. (orig.)

  5. Identification of dynamic properties of radial air-foil bearings

    NARCIS (Netherlands)

    Arora, Vikas; Arora, V.; van der Hoogt, Peter; Aarts, Ronald G.K.M.; de Boer, Andries

    2010-01-01

    Air-foil bearings (AFBs) are self acting hydrodynamic bearings made from sheet metal foils comprised of at least two layers. The innermost “top foil” layer traps a gas pressure film that supports a load while the layer or layers underneath provide an elastic foundation. Air-foil bearings are

  6. Orientation and alignment in beam tilted-foil spectroscopy

    International Nuclear Information System (INIS)

    Berry, H.G.

    1976-01-01

    The production of atomic orientation and alignment, by anisotropic excitation is analyzed. The stokes parameters of the light emitted from tilted-foil excited ions provide measurements of orientation and alignment, and some examples are given. The variations of the stokes parameters with foil tilt angle, excited state, ion velocity and foil material are compared with existing theories

  7. Stripping foils for the PSB H- injection system

    CERN Document Server

    Aiba, M; Goddard, B; Weterings, W

    2009-01-01

    Beam physics considerations for the stripping foil of the PSB H- injection system are described, including the arguments for the foil type, thickness, geometry and positioning. The foil performance considerations are described, including expected stripping efficiency, emittance growth, energy straggling, temperature and lifetime. The required movement ranges and tolerances are detailed, together with the assumptions used.

  8. Scaling laws for radial foil bearings

    Science.gov (United States)

    Honavara Prasad, Srikanth

    The effects of fluid pressurization, structural deformation of the compliant members and heat generation in foil bearings make the design and analysis of foil bearings very complicated. The complex fluid-structural-thermal interactions in foil bearings also make modeling efforts challenging because these phenomena are governed by highly non-linear partial differential equations. Consequently, comparison of various bearing designs require detailed calculation of the flow fields (velocities, pressures), bump deflections (structural compliance) and heat transfer phenomena (viscous dissipation in the fluid, frictional heating, temperature profile etc.,) resulting in extensive computational effort (time/hardware). To obviate rigorous computations and aid in feasibility assessments of foil bearings of various sizes, NASA developed the "rule of thumb" design guidelines for estimation of journal bearing load capacity. The guidelines are based on extensive experimental data. The goal of the current work is the development of scaling laws for radial foil bearings to establish an analytical "rule of thumb" for bearing clearance and bump stiffness. The use of scale invariant Reynolds equation and experimentally observed NASA "rule of thumb" yield scale factors which can be deduced from first principles. Power-law relationships between: a. Bearing clearance and bearing radius, and b. bump stiffness and bearing radius, are obtained. The clearance and bump stiffness values obtained from scaling laws are used as inputs for Orbit simulation to study various cases. As the clearance of the bearing reaches the dimensions of the material surface roughness, asperity contact breaks the fluid film which results in wear. Similarly, as the rotor diameter increases (requiring larger bearing diameters), the load capacity of the fluid film should increase to prevent dry rubbing. This imposes limits on the size of the rotor diameter and consequently bearing diameter. Therefore, this thesis aims

  9. Occlusion et posture

    OpenAIRE

    Le Breton, Alix

    2017-01-01

    L'objectif majeur de l'orthodontie est d'obtenir une occlusion fonctionnelle. Cette fonction occlusale est capitale dans la croissance du complexe maxillo-facial mais aussi dans la croissance et la statique générale du corps. Le champ d'action de l'orthodontiste s'inscrit donc dans une prise en charge globale. Il doit prendre conscience que son traitement risque d'influer sur la posture et modifier le schéma corporel du patient. Ce travail va dans un premier temps définir le système postural ...

  10. Carbon stripper foils held in place with carbon fibers

    International Nuclear Information System (INIS)

    Jolivet, Connie S.; Miller, Shawn A.; Stoner, John O.; Ladd, Peter

    2008-01-01

    The Spallation Neutron Source (SNS) currently under construction at Oak Ridge National Laboratory, Oak Ridge, Tennessee, is planned to initially utilize carbon stripper foils having areal densities approximately 260 μg/cm 2 . The projected design requires that each foil be supported by only one fixed edge. For stability of the foil, additional support is to be provided by carbon fibers. The feasibility of manufacturing and shipping such mounted carbon foils produced by arc evaporation was studied using two prototypes. Production of the foils is described. Fibers were chosen for satisfactory mechanical strength consistent with minimal interference with the SNS beam. Mounting of the fibers, and packaging of the assemblies for shipping are described. Ten completed assemblies were shipped to SNS for further testing. Preliminary evaluation of the survivability of the foils in the SNS foil changer is described

  11. Advances in targetry with thin diamond-like carbon foils

    CERN Document Server

    Liechtenstein, V K; Olshanski, E D; Repnow, R; Levin, J; Hellborg, R; Persson, P; Schenkel, T

    2002-01-01

    Thin and stable diamond-like carbon (DLC) foils, which were fabricated at the Kurchatov Institute by sputter deposition, have proved recently to be advantageous for stripping and secondary electron timing of high energy heavy ions in a number of accelerator experiments. This resulted in expanding applications of these DLC foils which necessitated further development efforts directed toward the following applications of DLC targetry: (i) thin stripper foils for lower energy tandem accelerators, (ii) enlarged (up to 66 mm in diameter) stop foils for improved time-of-flight elastic recoil detection ion beam analysis, and (iii) ultra-thin (about 0.6 mu g/cm sup 2) DLC foils for some fundamental and applied physics experiments. Along with the fabrication of thin DLC stripper foils for tandem accelerators, much thicker (up to 200 mu g/cm sup 2) foils for post-stripping of heavy-ion beams in higher energy linacs, are within reach.

  12. Analyzing Physiologic occlusion

    Directory of Open Access Journals (Sweden)

    M. Emamie

    1987-08-01

    Full Text Available Generally speaking, when preserving and restoring the gnathostomatic system the dentist controls tooth morphology to insure proper distribution of stress. So, we restore a portion of a tooth or all the teeth in such a manner as to subject the associated parts of the system to the least stress. We evaluate our diagnosis and control it in our treatment. The treatment should be based on the scientific method. We create optimal occlusion or a desirable functional state of the masticatory system.  Many persons with occlusal imperfections will not have symptoms of functional disorders. This is the psychological adaptive capacity of the neuromuscular system, teeth, dental arches, and periodontal tissues.Recent developments in dental material, technology and instruments however, have simplified the taskaf restoring rebuilding and rehabilitating diseased mouths. So, optimum oral health and function should be the prime objective of all treatment procedures. Because the ultimate aim will always be to restore the mouth to health and preserve this status throughout the life of a patient.

  13. Viscous investigation of a flapping foil propulsor

    Science.gov (United States)

    Posri, Attapol; Phoemsapthawee, Surasak; Thaweewat, Nonthipat

    2018-01-01

    Inspired by how fishes propel themselves, a flapping-foil device is invented as an alternative propulsion system for ships and boats. The performance of such propulsor has been formerly investigated using a potential flow code. The simulation results have shown that the device has high propulsive efficiency over a wide range of operation. However, the potential flow gives good results only when flow separation is not present. In case of high flapping frequency, the flow separation can occur over a short instant due to fluid viscosity and high angle of attack. This may cause a reduction of propulsive efficiency. A commercial CFD code based on Lattice Boltzmann Method, XFlow, is then employed in order to investigate the viscous effect over the propulsive performance of the flapping foil. The viscous results agree well with the potential flow results, confirming the high efficiency of the propulsor. As expected, viscous results show lower efficiency in high flapping frequency zone.

  14. Composite metal foil and ceramic fabric materials

    Science.gov (United States)

    Webb, Brent J.; Antoniak, Zen I.; Prater, John T.; DeSteese, John G.

    1992-01-01

    The invention comprises new materials useful in a wide variety of terrestrial and space applications. In one aspect, the invention comprises a flexible cloth-like material comprising a layer of flexible woven ceramic fabric bonded with a layer of metallic foil. In another aspect, the invention includes a flexible fluid impermeable barrier comprising a flexible woven ceramic fabric layer having metal wire woven therein. A metallic foil layer is incontinuously welded to the woven metal wire. In yet another aspect, the invention includes a material comprising a layer of flexible woven ceramic fabric bonded with a layer of an organic polymer. In still another aspect, the invention includes a rigid fabric structure comprising a flexible woven ceramic fabric and a resinous support material which has been hardened as the direct result of exposure to ultraviolet light. Inventive methods for producing such material are also disclosed.

  15. Brazing Inconel 625 Using the Copper Foil

    Science.gov (United States)

    Chen, Wen-Shiang; Wang, Cheng-Yen; Shiue, Ren-Kae

    2013-12-01

    Brazing Inconel 625 (IN-625) using the copper foil has been investigated in this research. The brazed joint is composed of nanosized CrNi3 precipitates and Cr/Mo/Nb/Ni quaternary compound in the Cu/Ni-rich matrix. The copper filler 50 μm in thickness is enough for the joint filling. However, the application of Cu foil 100 μm in thickness has little effect on the shear strength of the brazed joint. The specimen brazed at 1433 K (1160 °C) for 1800 seconds demonstrates the best shear strength of 470 MPa, and its fractograph is dominated by ductile dimple fracture with sliding marks. Decreasing the brazing temperature slightly decreases the shear strength of the brazed joint due to the presence of a few isolated solidification shrinkage voids smaller than 15 μm. Increasing the brazing temperature, especially for the specimen brazed at 1473 K (1200 °C), significantly deteriorates the shear strength of the joint below 260 MPa because of coalescence of isothermal solidification shrinkage voids in the joint. The Cu foil demonstrates potential in brazing IN-625 for industrial application.

  16. [Temporomandibular joint, occlusion and bruxism].

    Science.gov (United States)

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Monitoring the degradation of partly decomposable plastic foils

    Directory of Open Access Journals (Sweden)

    Rétháti Gabriella

    2014-11-01

    Full Text Available We have monitored the behaviour of different polyethylene foils including virgin medium density polyethylene (MDPE, MDPE containing pro-oxydative additives (238, 242 and MDPE with pro-oxydative additives and thermoplastic starch (297 in the soil for a period of one year. A foil based on a blend of polyester and polylactic acid (BASF Ecovio served as degradable control. The experiment was carried out by weekly measurements of conductivity and capacity of the soil, since the setup was analogous to a condenser, of which the insulating layer was the foil itself. The twelve replications allowed monthly sampling; the specimen taken out from the soil each month were tested visually for thickness, mechanical properties, morphological and structural changes, and molecular mass. Based on the obtained capacity values, we found that among the polyethylene foils, the one that contained thermoplastic starch extenuated the most. This foil had the greatest decrease in tensile strength and elongation at break due to the presence of thermoplastic starch. The starch can completely degrade in the soil; thus, the foil had cracks and pores. The polyethylene foils that contained pro-oxydant additives showed smaller external change compared to the virgin foil, since there was no available UV radiation and oxygen for their degradation. The smallest change occurred in the virgin polyethylene foil. Among the five examined samples, the commercially available BASF foil showed the largest extenuation and external change, and it deteriorated the most in the soil.

  18. Foil changer for the Chalk River superconducting cyclotron

    International Nuclear Information System (INIS)

    Hoffmann, C.R.; Kilborn, R.I.; Mouris, J.E.; Proulx, D.R.; Weaver, J.F.

    1985-01-01

    Capture of an injected beam in the Chalk River superconducting cyclotron requires that a carbon stripping foil be accurately placed in a dee to intercept the incoming beam. Foil radial position must be precisely adjustable and foils must be easily replaced. A foil changing apparatus has been designed, built and tested to meet these requirements. The main components are a supply magazine, a transport system, and unloading and loading mechanisms. The magazine is on top of the cyclotron. It holds 300 foils and can be isolated from machine vacuum for refilling. Each foil is mounted on a stainless steel frame. A stainless steel roller chain fitted with 33 copper sleeves (shrouds) carries foils, one per shroud, down a dee stem to the midplane. A 12-bit absolute optical shaft encoder senses foil position. To replace a foil a shroud is positioned at the top of the cyclotron, a foil is removed, and another is transferred from the magazine to the empty shroud. Three stepping motors and associated electronics provide mechanical drive and are interfaced with a CAMAC control system

  19. Method of forming a thin unbacked metal foil

    Science.gov (United States)

    Duchane, David V.; Barthell, Barry L.

    1984-01-01

    In a method of forming a thin (foil having a desired curviplanar shape, a soluble polymeric film, preferably comprising polyvinyl alcohol, is formed on a supporting structure having a shape that defines the desired shape of the foil product. A layer of metal foil is deposited onto one side of the soluble film, preferably by vacuum vapor deposition. The metallized film is then immersed in a suitable solvent to dissolve the film and thereby leave the metal foil as an unbacked metal foil element mounted on the supporting structure. Aluminum foils less than 0.2 .mu.m (2,000 .ANG.) thick and having an areal density of less than 54 .mu.g/cm.sup.2 have been obtained.

  20. Extreme extensibility of copper foil under compound forming conditions.

    Science.gov (United States)

    Yu, Qingbo; Liu, Xianghua; Tang, Delin

    2013-12-19

    A copper foil with an extreme extensibility up to 43,684% was obtained without any intermediate annealing by means of asynchronous rolling with high tension. It was found that under the combination of compression, shearing and tension, the copper foil represents a wonderful phenomenon. As the reduction increases, the specimen hardness increases up to a peak value 138 HV0.05 when the foil thickness rolled to around 100 μm, and then it decreases down to 78 HV0.05 when the foil thickness rolled to the final size 19 μm. It tells us that the strain-softening effect occurs when the foil thickness is rolled down to a threshold level. The experimental results bring us some fresh ideas different with the traditional understanding on the strain-hardening mechanism of metals, which provides an experimental basis to establish the forming mechanism of the thin foil.

  1. Effects of Aluminum Foil Packaging on Elemental Analysis of Bone.

    Science.gov (United States)

    Lewis, Lyniece; Christensen, Angi M

    2016-03-01

    Burned skeletal material is often very fragile and at high risk for fragmentation during packaging and transportation. One method that has been suggested to protect bones in these cases is to carefully wrap them in aluminum foil. Traces of aluminum, however, are known to transfer from foil packaging materials to food products. If such transfer occurs between aluminum foil and bones, it could interfere with subsequent chemical, elemental and isotopic analyses, which are becoming more common in forensic anthropological investigations. This study examined aluminum levels in bones prior to and following the use of aluminum foil packaging and storage for a 6-week period. Results indicate no significant change in the detected levels of aluminum (p > 0.05), even when packaged in compromised foil and exposed to elevated temperatures. Aluminum foil can therefore continue to be recommended as a packaging medium without affecting subsequent chemical examinations. © 2015 American Academy of Forensic Sciences.

  2. Microfabricated Segmented-Involute-Foil Regenerator for Stirling Engines

    Science.gov (United States)

    Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gedeon, David; Qiu, Songgang; Wood, Gary; Kelly, Kevin; McLean, Jeffrey

    2010-01-01

    An involute-foil regenerator was designed, microfabricated, and tested in an oscillating-flow test rig. The concept consists of stacked involute-foil nickel disks (see figure) microfabricated via a lithographic process. Test results yielded a performance of about twice that of the 90-percent random-fiber currently used in small Stirling converters. The segmented nature of the involute- foil in both the axial and radial directions increases the strength of the structure relative to wrapped foils. In addition, relative to random-fiber regenerators, the involute-foil has a reduced pressure drop, and is expected to be less susceptible to the release of metal fragments into the working space, thus increasing reliability. The prototype nickel involute-foil regenerator was adequate for testing in an engine with a 650 C hot-end temperature. This is lower than that required by larger engines, and high-temperature alloys are not suited for the lithographic microfabrication approach.

  3. Stresses in the foil of an electron accelerator extraction channel

    International Nuclear Information System (INIS)

    Abroyan, M.A.; Makarenko, T.I.; Tokmakov, I.L.

    1983-01-01

    Stresses in the foil of an electron accelerator extraction channel are assessed with account of contributions of thermal expansion and stress concentrations during switchings. Optimization of extraction grid parameters of the electron accelerator extraction channel and choice of foil material for high current electron beam is conducted. It is suggested that an extraction grid with circular cells and Al-Mg foil should be used. A simple formula applicable for design calculations is proposed for evaluation of stress concentration coefficient during phase switchings

  4. Characterization of U-Mo Foils for AFIP-7

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Danny J.; Ermi, Ruby M.; Schemer-Kohrn, Alan L.; Overman, Nicole R.; Henager, Charles H.; Burkes, Douglas; Senor, David J.

    2012-11-07

    Twelve AFIP in-process foil samples, fabricated by either Y-12 or LANL, were shipped from LANL to PNNL for potential characterization using optical and scanning electron microscopy techniques. Of these twelve, nine different conditions were examined to one degree or another using both techniques. For this report a complete description of the results are provided for one archive foil from each source of material, and one unirradiated piece of a foil of each source that was irradiated in the Advanced Test Reactor. Additional data from two other LANL conditions are summarized in very brief form in an appendix. The characterization revealed that all four characterized conditions contained a cold worked microstructure to different degrees. The Y-12 foils exhibited a higher degree of cold working compared to the LANL foils, as evidenced by the highly elongated and obscure U-Mo grain structure present in each foil. The longitudinal orientations for both of the Y-12 foils possesses a highly laminar appearance with such a distorted grain structure that it was very difficult to even offer a range of grain sizes. The U-Mo grain structure of the LANL foils, by comparison, consisted of a more easily discernible grain structure with a mix of equiaxed and elongated grains. Both materials have an inhomogenous grain structure in that all of the characterized foils possess abnormally coarse grains.

  5. Note: the influence of exploding foil shape on energy deposition.

    Science.gov (United States)

    Zeng, Qingxuan; Lv, Junjun; Li, Mingyu

    2013-06-01

    The main influence factors of exploding bridge foil were studied in order to improve energy utilization of the explosion foil initiator. "Square" and "curving" shaped bridge foils were fabricated using magnetron sputtering and chemical etching techniques, and the key dimension of the bridge foil was measured using surface profiler. Commercial software MATLAB was employed to calculate the burst current, burst voltage, and energy deposition. Simulation results were in good agreement with experiment data. In this study, the energy deposition ratio of "square" shaped bridge is between 45%-50%, while the value of "curving" shaped bridge is between 55%-75%.

  6. LENA Conversion Foils Using Single-Layer Graphene, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Implementing graphene foils in existing neutral atom detector designs will increase their angular and energy resolution, and also improve their mass discrimination...

  7. Foil focusing of relativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Jr., Carl August [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-26

    When an intense relativistic electron beams (IREB) passes through a grounded metal foil, the transverse electric field due to the beam space charge is locally shorted out, and the beam is focused by the magnetic field of its current. The effect can be treated as focusing by a thin lens with first order aberration. Expressions for the focal length and aberration coefficient of the equivalent thin lens are developed in this note. These are then applied to practical examples representative of IREB research at Los Alamos National Laboratory.

  8. The Los Alamos foil implosion project

    International Nuclear Information System (INIS)

    Brownell, J.; Parker, J.; Bartsch, R.; Benage, J.; Bowers, R.; Cochrane, J.; Forman, P.; Goforth, J.; Greene, A.; Kruse, H.

    1993-01-01

    The goal of the Los Alamos foil implosion project is to produce an intense (>100 TW), multi-megajoule, laboratory soft x-ray source for material studies and fusion experiments. The concept involves the implosion of annular, current-carrying, cylindrical metallic plasmas via their self-magnetic forces. The project features inductive storage systems using both capacitor banks and high explosive-driven flux compression generators as prime energy sources. Fast opening switches are employed to shorten the electrical pulses. The program will be described and activities to date will be summarized

  9. Bilateral internal carotid artery occlusion

    International Nuclear Information System (INIS)

    Yamamoto, Yasumasa; Tsuda, Harumi; Nabatame, Hidehiko; Akiguchi, Ichiro; Kameyama, Masakuni.

    1987-01-01

    Four cases of bilateral internal carotid occlusion are reported with respect to clinical features, hemodynamics and various image diagnosis. MRI is applied to three cases. The patients comprised 2.08 % of all cerebral occlusive diseases treated during the past five years at our clinic. One case is of abrupt onset and three cases are progressing profiles. In one of these cases, collateral circulation is supplied mainly by leptomeningeal anastomosis of the posterior cerebral artery and posterior pericallosal artery branching from the basilar artery. In two of them, they are supplied through the circle of Willis. Middle cerebral artery occlusion, occlusion supra occlusionem, however, causes decisive ischemic lesion in its teritory. Applying MRI, complicated ischemic lesions, such as lacunar infarction, paraventricular lesion, deep white matter lesion and border zone infarction can clearly be identified. In the case of total aphasia, the lesions responsible are demonstrated clearly by MRI, but only vaguely by X-ray CT. (author)

  10. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  11. Actinide Foil Production for MPACT Research

    Energy Technology Data Exchange (ETDEWEB)

    Beller, Denis

    2012-10-30

    Sensitive fast-neutron detectors are required for use in lead slowing down spectrometry (LSDS), an active interrogation technique for used nuclear fuel assay for Materials Protection, Accounting, and Controls Technologies (MPACT). During the past several years UNLV sponsored a research project at RPI to investigate LSDS; began development of fission chamber detectors for use in LSDS experiments in collaboration with INL, LANL, and Oregon State U.; and participated in a LSDS experiment at LANL. In the LSDS technique, research has demonstrated that these fission chamber detectors must be sensitive to fission energy neutrons but insensitive to thermal-energy neutrons. Because most systems are highly sensitive to large thermal neutron populations due to the well-known large thermal cross section of 235U, even a miniscule amount of this isotope in a fission chamber will overwhelm the small population of higher-energy neutrons. Thus, fast-fission chamber detectors must be fabricated with highly depleted uranium (DU) or ultra-pure thorium (Th), which is about half as efficient as DU. Previous research conducted at RPI demonstrated that the required purity of DU for assay of used nuclear fuel using LSDS is less than 4 ppm 235U, material that until recently was not available in the U.S. In 2009 the PI purchased 3 grams of ultra-depleted uranium (uDU, 99.99998% 238U with just 0.2 ± 0.1 ppm 235U) from VNIIEF in Sarov, Russia. We received the material in the form of U3O8 powder in August of 2009, and verified its purity and depletion in a FY10 MPACT collaboration project. In addition, chemical processing for use in FC R&D was initiated, fission chamber detectors and a scanning alpha-particle spectrometer were developed, and foils were used in a preliminary LSDS experiment at a LANL/LANSCE in Sept. of 2010. The as-received U3O8 powder must be chemically processed to convert it to another chemical form while maintaining its purity, which then must be used to electro-deposit U

  12. Design and optimization of vertex detector foils by superplastic forming

    NARCIS (Netherlands)

    Snippe, Q.H.C.

    2011-01-01

    The production of one of the parts in a particle detector, called the RF Foil, has been a very intensive process in the past. The design and production process, which had a trial and error character, led eventually to an RF Foil that met the most important requirement: a sufficient leak tightness

  13. Foil fabrication for the ROMANO event. Revision 1

    International Nuclear Information System (INIS)

    Romo, J.G. Jr.; Weed, J.W.; Griggs, G.E.; Brown, T.G.; Tassano, P.L.

    1984-01-01

    The Vacuum Processes Lab (VPL), of LLNL's M.E. Dept. - Material Fabrication Division (MFD), conducted various vacuum related support activities for the ROMANO nuclear physics experiment. This report focuses on the foil fabrication activities carried out between July and November 1983 for the ROMANO event. Other vacuum related activities for ROMANO, such as outgassing tests of materials, are covered in separate documentation. VPL was asked to provide 270 coated Parylene foils for the ROMANO event. However, due to the developmental nature of some of the procedures, approximately 400 coated foils were processed. In addition, VPL interacted with MFD's Plastics Shop to help supply Parylene substrates to other organizations (i.e., LBL and commercial vendors) which had also been asked to provide coated foils for ROMANO. The purposes of this report are (A) to document the processes developed and the techniques used to produce the foils, and (B) to suggest future directions. The report is divided into four sections describing: (1) nuclear target foil fabrication, (2) Parylene substrate preparation and production, (3) calibration foil fabrication, and (4) foil and substrate inspections

  14. Practical and research aspects of beam-foil spectroscopy

    International Nuclear Information System (INIS)

    Bashkin, S.

    1974-01-01

    Practical aspects of the application of low-energy accelerators to research in beam-foil spectroscopy are discussed, and the kinds of equipment and associated costs are described in some detail. Some typical beam-foil experiments, emphasizing the most recent studies, are treated so as to show how relatively simple facilities can be used to produce physics of great interest

  15. Lithographic patterning of metals on flexible plastic foils

    NARCIS (Netherlands)

    Peter, M.; Furthner, F.; Deen, J.; Laat, W.J.M.de; Meinders, E.R.

    2009-01-01

    In this paper the challenges of patterning electrodes with separations in the micron and sub-micron range onto thin polyethylene naphthalate foils for use in biochips are discussed. It was found that it was necessary to improve the adhesion of the metal electrodes to the foil by using plasma

  16. Comparison of the occlusal vertical dimension after processing complete dentures made with lingualized balanced occlusion and conventional balanced occlusion.

    Science.gov (United States)

    Basso, Michael Frederico Manzolli; Nogueira, Sergio Sualdini; Arioli-Filho, Joao Neudenir

    2006-09-01

    An increase in occlusal vertical dimension (OVD) may occur after processing complete dentures. Although many factors that generate this change are known, no information is available in the dental literature regarding the effect that the occlusal scheme may have on the change in OVD. This in vitro study compared the increase in OVD, after processing, between complete dentures with teeth arranged in lingualized balanced occlusion and conventional balanced occlusion. Thirty sets of complete dentures were evaluated as follows: 15 sets of complete dentures were arranged in conventional balanced occlusion (control) and 15 sets of complete dentures were arranged in lingualized balanced occlusion. All dentures were compression molded with a long polymerization cycle. The occlusal vertical dimension was measured with a micrometer (mm) before and after processing each set of dentures. Data were analyzed using an independent t test (alpha=.05). The mean increase in the OVD, after processing, was 0.87 +/- 0.21 mm for the control group and 0.90 +/- 0.27 mm for the experimental group. There was no significant difference between the groups. After processing, dentures set in lingualized balanced occlusion showed an increase in OVD similar to those set in conventional balanced occlusion. Although the 2 occlusal concepts resulted in similar increases in the OVD after processing, the lingualized balanced occlusion may result in easier occlusal adjustments, as the less complicated occlusal scheme uses a smaller number of centric occlusion contact points.

  17. Characterization of the water diffusion in GEM foil material

    Science.gov (United States)

    Benussi, L.; Bianco, S.; Saviano, G.; Muhammad, S.; Piccolo, D.; Raffone, G.; Caponero, M.; Passamonti, L.; Pierluigi, D.; Russo, A.; Primavera, F.; Cerbelli, S.; Lalli, A.; Valente, M.; Ferrini, M.; Teissandier, B.; Taborelli, M.; Parvis, M.; Grassini, S.; Tirilló, J.; Sarasini, F.; Franchi, A. V.

    2018-02-01

    Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this compound inside the detector' s foil can possibly change its mechanical and electrical properties, and in such a way, the detector performance can be affected. To understand this phenomenon, a model is developed with COMSOL Multiphysics v. 4.3 [1], which described the adsorption and diffusion within the geometry of GEM foil, the concentration profiles and the time required to saturate the foil. The COMSOL model is verified by experimental observations on a GEM foil sample. This note will describe the model and its experimental verification results.

  18. Gas Foil Bearing Misalignment and Unbalance Effects

    Science.gov (United States)

    Howard, Samuel A.

    2008-01-01

    The effects of misalignment and unbalance on gas foil bearings are presented. The future of U.S. space exploration includes plans to conduct science missions aboard space vehicles, return humans to the Moon, and place humans on Mars. All of these endeavors are of long duration, and require high amounts of electrical power for propulsion, life support, mission operations, etc. One potential source of electrical power of sufficient magnitude and duration is a nuclear-fission-based system. The system architecture would consist of a nuclear reactor heat source with the resulting thermal energy converted to electrical energy through a dynamic power conversion and heat rejection system. Various types of power conversion systems can be utilized, but the Closed Brayton Cycle (CBC) turboalternator is one of the leading candidates. In the CBC, an inert gas heated by the reactor drives a turboalternator, rejects excess heat to space through a heat exchanger, and returns to the reactor in a closed loop configuration. The use of the CBC for space power and propulsion is described in more detail in the literature (Mason, 2003). In the CBC system just described, the process fluid is a high pressure inert gas such as argon, krypton, or a helium-xenon mixture. Due to the closed loop nature of the system and the associated potential for damage to components in the system, contamination of the working fluid is intolerable. Since a potential source of contamination is the lubricant used in conventional turbomachinery bearings, Gas Foil Bearings (GFB) have high potential for the rotor support system. GFBs are compliant, hydrodynamic journal and thrust bearings that use a gas, such as the CBC working fluid, as their lubricant. Thus, GFBs eliminate the possibility of contamination due to lubricant leaks into the closed loop system. Gas foil bearings are currently used in many commercial applications, both terrestrial and aerospace. Aircraft Air Cycle Machines (ACMs) and ground

  19. Thin foil expansion into a vacuum

    International Nuclear Information System (INIS)

    Mora, P.

    2005-01-01

    Plasma expansion into a vacuum is an old problem which has been renewed recently in various contexts: expansion of ultra-cold plasmas, cluster expansion, of dust grains, expansion of thin foils. In this presentation I will first discuss the physics of the expansion of a thin foil irradiated by an ultra-short ultra-intense laser pulse. The expansion results in the formation of high energy ions. For an infinitely steep plasma-vacuum interface the fastest ions are located in the outer part of the expansion and their velocity is given by ν m ax∼ 2 C s (In ω p it) where c s (Zk B T e /m i )''1/2 is the ion-acoustic velocity ω p i=(n e 0Ze''2/m i e 0 )''1/2 is the ion plasma frequency, n e 0 is the electron density in the unperturbed plasma, Z is the ion charge number. In the above expression, t is either the pulse duration or the effective acceleration time (in particular t∼L/2c s , where L is the width of the foil, when the electron cooling is taken into account). A salient characteristic of the expansion is the occurrence of a double layer structure and a peak of the accelerating electric field at the ion front. I will explain the origin of the peak and predict its temporal behavior. This peak has been diagnosed in recent experiments. I will also discuss the effect of a 2-temperatures electron distribution function on the expansion, showing the dominant role of the hot electron component. Finally I will discuss the occurrence of ion spikes in the expansion when the initial density profile is smooth. The ion spike is due to a wave breaking which cannot be handled in a satisfactory way by a fluid code and requires a kinetic description. A. simple collisionless particle code has been used to treat the evolution of the spike after the wave breaking and the results will be shown. (Author)

  20. Design considerations for foil windows for PET radioisotope targets

    International Nuclear Information System (INIS)

    Hughey, B.J.; Shefer, R.E.; Klinkowstein, R.E.; Welch, M.J.

    1992-01-01

    This paper describes the results of a study performed at SRL to develop analytical and computational techniques for optimizing the design of conduction-cooled foil windows for PET targets. Single foil conduction cooled windows have been found to be good target entrance windows for both low energy accelerators and medium energy cyclotrons. Detailed thermal analysis has given an approximate analytical expression for the maximum temperature reached in a foil window under conditions of realistic ion beam bombardment. The effects of 'hot spots' in the beam density profile were investigated. It was shown that a factor of two safety margin in window design should be adequate to compensate for any possible beam hot spots. In addition, the reduction of foil stress by slack mounting was verified by experiments. The properties of conventional and novel foil materials were investigated for use in conduction cooled windows. Novel foil materials include two-component Al/Ti and Al/Havar foil. Results on the testing of candidate foil materials for thermal conductivity and mechanical strength at elevated temperature were presented. Two optimum foil window geometries were analyzed: a high aspect ratio window and a multiply slotted window. The multiply slotted window combines the advantages of a high aspect ratio foil window with a circular beam strike and is a promising window design for both TCA and cyclotron targets. A multiply slotted window for a N 2 gas target for 15 O production was designed using the methodologies discussed above. This prototype target was successfully tested using the TCA beam at SRL. (author) 6 figs., 3 tabs., 10 refs

  1. Foil Gas Thrust Bearings for High-Speed Turbomachinery

    Science.gov (United States)

    Edmonds, Brian; DellaCorte, Christopher; Dykas, Brian

    2010-01-01

    A methodology has been developed for the design and construction of simple foil thrust bearings intended for parametric performance testing and low marginal costs, supporting continued development of oil-free turbomachinery. A bearing backing plate is first machined and surface-ground to produce flat and parallel faces. Partial-arc slots needed to retain the foil components are then machined into the plate by wire electrical discharge machining. Slot thicknesses achievable by a single wire pass are appropriate to accommodate the practical range of foil thicknesses, leaving a small clearance in this hinged joint to permit limited motion. The backing plate is constructed from a nickel-based superalloy (Inconel 718) to allow heat treatment of the entire assembled bearing, as well as to permit hightemperature operation. However, other dimensionally stable materials, such as precipitation-hardened stainless steel, can also be used for this component depending on application. The top and bump foil blanks are cut from stacks of annealed Inconel X-750 foil by the same EDM process. The bump foil has several azimuthal slits separating it into five individual bump strips. This configuration allows for variable bump spacing, which helps to accommodate the effects of the varying surface velocity, thermal crowning, centrifugal dishing, and misalignment. Rectangular tabs on the foil blanks fit into the backing plate slots. For this application, a rather traditional set of conventionally machined dies is selected, and bump foil blanks are pressed into the dies for forming. This arrangement produces a set of bump foil dies for foil thrust bearings that provide for relatively inexpensive fabrication of various bump configurations, and employing methods and features from the public domain.

  2. Occlusion-Aware View Interpolation

    Directory of Open Access Journals (Sweden)

    Ince Serdar

    2008-01-01

    Full Text Available Abstract View interpolation is an essential step in content preparation for multiview 3D displays, free-viewpoint video, and multiview image/video compression. It is performed by establishing a correspondence among views, followed by interpolation using the corresponding intensities. However, occlusions pose a significant challenge, especially if few input images are available. In this paper, we identify challenges related to disparity estimation and view interpolation in presence of occlusions. We then propose an occlusion-aware intermediate view interpolation algorithm that uses four input images to handle the disappearing areas. The algorithm consists of three steps. First, all pixels in view to be computed are classified in terms of their visibility in the input images. Then, disparity for each pixel is estimated from different image pairs depending on the computed visibility map. Finally, luminance/color of each pixel is adaptively interpolated from an image pair selected by its visibility label. Extensive experimental results show striking improvements in interpolated image quality over occlusion-unaware interpolation from two images and very significant gains over occlusion-aware spline-based reconstruction from four images, both on synthetic and real images. Although improvements are obvious only in the vicinity of object boundaries, this should be useful in high-quality 3D applications, such as digital 3D cinema and ultra-high resolution multiview autostereoscopic displays, where distortions at depth discontinuities are highly objectionable, especially if they vary with viewpoint change.

  3. High strain rate metalworking with vaporizing foil actuator: control of flyer velocity by varying input energy and foil thickness.

    Science.gov (United States)

    Vivek, A; Hansen, S R; Daehn, Glenn S

    2014-07-01

    Electrically driven rapid vaporization of thin metallic foils can generate a high pressure which can be used to launch flyers at high velocities. Recently, vaporizing foil actuators have been applied toward a variety of impulse-based metal working operations. In order to exercise control over this useful tool, it is imperative that an understanding of the effect of characteristics of the foil actuator on its ability for mechanical impulse generation is developed. Here, foil actuators made out of 0.0508 mm, 0.0762 mm, and 0.127 mm thick AA1145 were used for launching AA2024-T3 sheets of thickness 0.508 mm toward a photonic Doppler velocimeter probe. Launch velocities ranging between 300 m/s and 1100 m/s were observed. In situ measurement of velocity, current, and voltage assisted in understanding the effect of burst current density and deposited electrical energy on average pressure and velocity with foil actuators of various thicknesses. For the pulse generator, geometry, and flyer used here, the 0.0762 mm thick foil was found to be optimal for launching flyers to high velocities over short distances. Experimenting with annealed foil actuators resulted in no change in the temporal evolution of flyer velocity as compared to foil actuators of full hard temper. A physics-based analytical model was developed and found to have reasonable agreement with experiment.

  4. {beta}-nmr of Palladium foil

    Energy Technology Data Exchange (ETDEWEB)

    Parolin, T.J. [Department of Chemistry, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Salman, Z. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada); Chakhalian, J. [Max-Plank Institute for Solid State Research, D-70569 Stuttgart (Germany); Wang, D. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Keeler, T.A. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Hossain, Md. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Kiefl, R.F. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada); Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Canadian Institute for Advanced Research (Canada); Chow, K.H. [Department of Physics, University of Alberta, Edmonton, AB, T6G 2J1 (Canada); Morris, G.D. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada); Miller, R.I. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada); MacFarlane, W.A. [Department of Chemistry, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada)]. E-mail: wam@chem.ubc.ca

    2006-03-31

    Beta-detected NMR ({beta}-nmr) of low-energy implanted {sup 8}Li{sup +} was studied in metallic palladium. The resonance was found to have a large negative shift with respect to the reference signal in the cubic insulator MgO. This shift exhibited significant temperature dependence on cooling below room temperature, approximately proportionate to the temperature-dependent spin susceptibility of pure Pd. Thus it is tentatively attributed to a Knight shift (K) caused by a large negative hyperfine coupling; a phenomenon common in transition metal ions, but not in alkalis. However, the spin-lattice relaxation of {sup 8}Li is much slower than expected from the Korringa law for such a large K. We compare results from samples of very different thicknesses: 12.5{mu}m foil and a 100nm thin film.

  5. Large-area beryllium metal foils

    Science.gov (United States)

    Stoner, J. O., Jr.

    1997-02-01

    To manufacture beryllium filters having diameters up to 82 mm and thicknesses in the range 0.1-1 μm, it was necessary to construct apparatus in which the metal could safely be evaporated, and then to find an acceptable substrate and evaporation procedure. The metal was evaporated resistively from a tantalum dimple boat mounted in a baffled enclosure that could be placed in a conventional vacuum bell jar, obviating the need for a dedicated complete vacuum system. Substrates were 102 mm × 127 mm × 0.05 mm cleaved mica sheets, coated with 0.1 μm of NaCl, then with approximately 50 μg/cm 2 of cellulose nitrate. These were mounted on poly(methyl methacrylate) sheets 3 mm thick that were in turn clamped to a massive aluminum block for thermal stability. Details of the processes for evaporation, float off, and mounting are given, and the resulting foils described.

  6. Preparation of selenium coatings onto beryllium foils

    International Nuclear Information System (INIS)

    Erikson, E.D.; Tassano, P.L.; Reiss, R.H.; Griggs, G.E.

    1984-09-01

    A technique for preparing selenium films onto 50.8 microns thick beryllium foils is described. The selenium was deposited in vacuum from a resistance heated evaporation source. Profilometry measurements of the coatings indicate deposit thicknesses of 5.5, 12.9, 37.5, 49.8 and 74.5 microns. The control of deposition rate and of coating thickness was facilitated using a commercially available closed-loop programmable thin film controller. The x-ray transmission of the coated substrates was measured using a tritiated zirconium source. The transmissivities of the film/substrate combination are presented for the range of energies from 4 to 20 keV. 15 references, 3 figures

  7. Compliant Foil Journal Bearing Performance at Alternate Pressures and Temperatures

    Science.gov (United States)

    Bruckner, Robert J.; Puleo, Bernadette J.

    2008-01-01

    An experimental test program has been conducted to determine the highly loaded performance of current generation gas foil bearings at alternate pressures and temperatures. Typically foil bearing performance has been reported at temperatures relevant to turbomachinery applications but only at an ambient pressure of one atmosphere. This dearth of data at alternate pressures has motivated the current test program. Two facilities were used in the test program, the ambient pressure rig and the high pressure rig. The test program utilized a 35 mm diameter by 27 mm long foil journal bearing having an uncoated Inconel X-750 top foil running against a shaft with a PS304 coated journal. Load capacity tests were conducted at 3, 6, 9, 12, 15, 18, and 21 krpm at temperatures from 25 to 500 C and at pressures from 0.1 to 2.5 atmospheres. Results show an increase in load capacity with increased ambient pressure and a reduction in load capacity with increased ambient temperature. Below one-half atmosphere of ambient pressure a dramatic loss of load capacity is experienced. Additional lightly loaded foil bearing performance in nitrogen at 25 C and up to 48 atmospheres of ambient pressure has also been reported. In the lightly loaded region of operation the power loss increases for increasing pressure at a fixed load. Knowledge of foil bearing performance at operating conditions found within potential machine applications will reduce program development risk of future foil bearing supported turbomachines.

  8. Rolling and pitching oscillating foil propulsion in ground effect.

    Science.gov (United States)

    Perkins, Matthew D; Elles, Dane; Badlissi, George; Mivehchi, Amin; Dahl, Jason; Licht, Stephen

    2017-09-04

    In this paper, we investigate the effect of operating near a solid boundary on the forces produced by harmonically oscillating thrust generating foils. A rolling and pitching foil was towed in a freshwater tank in a series of experiments with varying kinematics. Hydrodynamic forces and torques were measured in the free stream and at varying distances from a solid boundary, and changes in mean lift and thrust were found when the foil approached the boundary. The magnitude of this ground effect exhibited a strong nonlinear dependence on the distance between the foil and the boundary. Significant effects were found within three chord lengths of the boundary, and ground effect can be induced at greater distances from the boundary by biasing the tip of the foil toward the boundary. Lift coefficients changed by as much as 0.2 at the closest approach to the ground, with changes ≥0.05 for all cases across Strouhal number ranging from 0.3 to 0.6, and nominal maximum angle of attack ranging from 20° to 40°. The ubiquity of the ground effect in high thrust kinematics suggests that the ground effect can provide a passive obstacle avoidance capability for foil propelled vehicles. By comparison to previous experimental work, we find that the ground effect experienced by a high-aspect ratio rolling and pitching foil is a fully three-dimensional phenomenon, as it is not accurately predicted when two-dimensional flow and/or two-dimensional kinematics are enforced. While two dimensional foil kinematics are more easily modeled for numerical studies, three-dimensional foil kinematics may be more practical for real world implementation in underwater vehicles. © 2017 IOP Publishing Ltd.

  9. A novel carbon coating technique for foil bolometers.

    Science.gov (United States)

    Sheikh, U A; Duval, B P; Labit, B; Nespoli, F

    2016-11-01

    Naked foil bolometers can reflect a significant fraction of incident energy and therefore cannot be used for absolute measurements. This paper outlines a novel coating approach to address this problem by blackening the surface of gold foil bolometers using physical vapour deposition. An experimental bolometer was built containing four standard gold foil bolometers, of which two were coated with 100+ nm of carbon. All bolometers were collimated and observed the same relatively high temperature, ohmically heated plasma. Preliminary results showed 13%-15% more incident power was measured by the coated bolometers and this is expected to be much higher in future TCV detached divertor experiments.

  10. Preparation of self-supporting metallic foils of nickel isotopes

    International Nuclear Information System (INIS)

    Sugai, Isao.

    1975-01-01

    This is the fourth report on the practical methods of target preparation for use in low energy nuclear experiments following the previous one (INS-J-150). An electroplating method has been developed as a dependable and reproducible technique for making self-supporting metallic foils of nickel in the thickness range of 0.5 to 10 mg/cm 2 . The procedures minimized the necessary amount of material so that nickel isotopes could be processed economically. Impurity contamination of the nickel foils during the electroplating process was less than 500 ppm, and the thickness variation in each foil was less than 3% of the central thickness. (auth.)

  11. Elevated Temperature Tensile Tests on DU–10Mo Rolled Foils

    Energy Technology Data Exchange (ETDEWEB)

    Schulthess, Jason [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    Tensile mechanical properties for uranium-10 wt.% molybdenum (U–10Mo) foils are required to support modeling and qualification of new monolithic fuel plate designs. It is expected that depleted uranium-10 wt% Mo (DU–10Mo) mechanical behavior is representative of the low enriched U–10Mo to be used in the actual fuel plates, therefore DU-10Mo was studied to simplify material processing, handling, and testing requirements. In this report, tensile testing of DU-10Mo fuel foils prepared using four different thermomechanical processing treatments were conducted to assess the impact of foil fabrication history on resultant tensile properties.

  12. Method of fabricating a uranium-bearing foil

    Science.gov (United States)

    Gooch, Jackie G [Seymour, TN; DeMint, Amy L [Kingston, TN

    2012-04-24

    Methods of fabricating a uranium-bearing foil are described. The foil may be substantially pure uranium, or may be a uranium alloy such as a uranium-molybdenum alloy. The method typically includes a series of hot rolling operations on a cast plate material to form a thin sheet. These hot rolling operations are typically performed using a process where each pass reduces the thickness of the plate by a substantially constant percentage. The sheet is typically then annealed and then cooled. The process typically concludes with a series of cold rolling passes where each pass reduces the thickness of the plate by a substantially constant thickness amount to form the foil.

  13. Endograft Limb Occlusion in EVAR

    DEFF Research Database (Denmark)

    Taudorf, M; Jensen, L P; Vogt, K C

    2014-01-01

    % at 3 years. Logistic regression showed that iliac artery tortuosity (DIS) (p = .001) and body mass index (p = .007) had a significant impact on graft patency. CONCLUSION: A tortuous vessel on the preoperative CTA is associated with an increased risk of limb occlusion after EVAR. Adjunctive stenting...

  14. Temporomandibular Disorders Treatment with Correction of Decreased Occlusal Vertical Dimension

    Directory of Open Access Journals (Sweden)

    Ljuben Guguvcevski

    2017-10-01

    CONCLUSION: Occlusal splint is a part of reversible occlusal therapy in cases with decreased occlusal vertical dimension. After reducing the symptoms related to decreased occlusal vertical dimension definitive prosthetic therapy can be done.

  15. Cephalometric analysis for functional occlusion

    Directory of Open Access Journals (Sweden)

    Ashok Karad

    2016-01-01

    Full Text Available Background: Various elements contributing to good functional occlusion have not been clearly assessed with cephalometrics for the diagnosis of functional problems and their application in clinical practice. The aim of this study, therefore, was to analyze different components of functional occlusion to formulate concise functional cephalometric analysis. Materials and Methods: Eighty-two cases (38 males and 44 females, with class I occlusion and balanced facial profile, were examined based on the selection criteria, and cephalograms were taken in natural head position. All the radiographs were then analyzed using various functional parameters. Results: The mean values of condylar path angle and incisal path angle were 55.83° and 65.67°, respectively, with large deviations. However, both showed positive correlation. The value of the angle of long axis of mandibular incisor with respect to the line joining center of condyle and lower incisor tip was 88.04°. Moreover, the angle between the occlusal plane and horizontal plane was 12.88°. In vertical plane, lower face height (LFH was found to be slightly less than the upper face height. Maxilla contributed around 45% of the LFH while mandible formed about 60%. Furthermore, upper alveolar component (maxillary alveolar height formed more than half of the maxilla (53.79% whereas lower alveolar component (mandibular alveolar height was 74.8% of the mandible. Conclusion: This study has analyzed various components of functional occlusion and formulated a concise functional cephalometric analysis for diagnosis, treatment planning, and assessment of treatment results.

  16. Malignant occlusion of the coeliac axis

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, K.; Wattsgaard, C.; Genell, S. (Malmoe Allmaenna Sjukhus, Malmoe (Sweden). Dept. of Diagnostic Radiology)

    1982-01-01

    Occlusion or extensive stenosis of the coeliac trunk due to malignant tumor are described in three patients. If, at angiography of a patient with a malignant tumor, occlusion of the coeliac trunk is found, tumor or lymph node metastases causing the occlusion must be considered; this may be of importance when intra-arterial chemotherapy of the tumor is planned.

  17. [The occlusal contact mode during lateral excursion].

    Science.gov (United States)

    Sugawara, N

    2000-09-01

    The purpose of this study is to clarify the occlusal contact mode between the upper and lower molars on the working side of group function occlusion during lateral excursion. After the intercuspal position (IP) and two lateral positions (L1, the middle point between IP and L2; L2, the edge-to-edge occlusal position of the molars) on the Gothic arch were defined, occlusal contact relations in these three occlusal positions were recorded, using black silicone. Digital data of real occlusal contacts and visualized data of close (less than 30 microns) occlusal areas, by computer image processing, were analyzed. The conclusions are as follows: 1. Although the numbers of real occlusal contacts and the visualized occlusal area tend to decrease toward L2 during lateral excursion, the former, in some cases, goes up and down. 2. Functional cusps play an important part in occlusal contact at the intercuspal position. 3. Occlusal contact points are on the functional cusps of the upper and lower molars, which can be clinically regarded as certain points, and these points slide on the inclining non-functional cusps of antagonistic teeth during lateral excursion. 4. Each upper and lower molar has 2 to 6 occlusal contact points near the top functional cusps at the intercuspal position, and some of them contact continuously during lateral excursion.

  18. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Tin-coated lead foil capsules for wine bottles. 189... lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one... covering applied over the cork and neck areas) on wine bottles to prevent insect infestation, as a barrier...

  19. 75 FR 1596 - Grant of Authority for Subzone Status, Reynolds Packaging LLC (Aluminum Foil Liner Stock...

    Science.gov (United States)

    2010-01-12

    ... Status, Reynolds Packaging LLC (Aluminum Foil Liner Stock), Louisville, Kentucky Pursuant to its...-purpose subzone at the aluminum foil liner stock manufacturing and distribution facilities of Reynolds... manufacturing and distribution of aluminum foil liner stock and aluminum foil at the facilities of Reynolds...

  20. Finite Element Modelling of Bends and Creases during Folding Ultra Thin Stainless Steel Foils

    NARCIS (Netherlands)

    Datta, K.; Akagi, H.; Geijselaers, Hubertus J.M.; Huetink, Han

    2003-01-01

    Finite Element Modelling of an ultra thin foil of SUS 304 stainless steel is carried out. These foils are 20 mm and below in thickness. The development of stresses and strains during folding of these foils is studied. The objective of this study is to induce qualities of paper in the foils of

  1. Controlled electropolishing of copper foils at elevated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Gi Duk; Kim, Young Woo; Moyen, Eric; Keum, Dong Hoon [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Lee, Young Hee [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); IBS Center for Integrated Nanostructure Physics (CINAP), Institute of Basic Science (IBS), Daejeon (Korea, Republic of); Department of Physics, Sungkyunkwan Advanced Institute of Nano-technology (SAINT), Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Baik, Seunghyun [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); School of Mechanical Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); IBS Center for Integrated Nanostructure Physics (CINAP), Institute of Basic Science (IBS), Daejeon (Korea, Republic of); Pribat, Didier, E-mail: didier53@skku.edu [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2014-07-01

    We have studied the electrochemical polishing of copper foils at elevated temperature, in H{sub 3}PO{sub 4} electrolytes of various concentrations. Atomic force microscopy, surface reflectance measurements as well as optical microscopy and scanning electron microscopy (including electron backscattering diffraction) have been used throughout this study to characterize the surface of the electropolished foils. We have found that copper foils electropolished at 65 °C in 2.17 M H{sub 3}PO{sub 4}, exhibited a lower surface roughness and a higher percent specular reflection, comparing with values obtained after classical electropolishing in concentrated H{sub 3}PO{sub 4} at room temperature or comparing with values obtained after chemical-mechanical polishing. This work could open up new prospects for the preparation of copper foils before the growth of high quality graphene layers.

  2. A study of molecular effects in beam-foil spectroscopy

    International Nuclear Information System (INIS)

    Andresen, B.; Veje, E.

    1979-01-01

    Relative populations of ns + nd levels in hydrogen as functions of the principal quantum number n have been measured with beams of H + , H 2 + , and H 3 + impinging on thin carbon foils at 25 keV/amu and 100 keV/amu. Enhancements of 20% and 45% for dimer and trimer clusters are observed uniformly for all levels. A possible explanation in terms of screening of the Coulomb repulsion between the protons inside the foil, thus reducing the effective thickness of the foil, is given. All relative populations closely follow an nsup(P) power law with p = -4.0 and -3.7 at 25 keV/amu and 100 keV/amu, respectively, in perfect analogy with atomic collision experiments. O + /O 2 + -foil excitations at 100 keV and 155 keV show a simular molecular effect, but in reverse with a larger mean charge produced by the dimer. (Auth.)

  3. A procedure for rapid evaluation of carbon stripper foils

    International Nuclear Information System (INIS)

    Auble, R.L.; Galbraith, D.M.

    1982-01-01

    Lifetime measurements on carbon foils can become prohibitively time consuming and expensive with conventional particle accelerator beams. Therefore, a method has been developed which utilizes a beam of low energy (20 keV) nitrogen ions which allows tests to be conducted on relatively inexpensive equipment at very high damage rates. The beam is obtained from a General Ionex Model 1080 Sputterbell. Beam currents of the order of 1 μA cm -2 lead to failure of glow-discharge type foils on a time scale of, typically, 5-10 min. Lifetime ratios for glow-discharge versus evaporated foils obtained with this technique are in good agreement with those obtained with higher energy beams. Relative lifetimes for high energy and low energy bombardments are also found to be in good agreement with those predicted by damage energy calculations. The technique is currently being applied to the testing of glow discharge foils made with different feed gases and discharge conditions. (orig.)

  4. Decontamination with pasty pickling agents forming a strippable foil

    International Nuclear Information System (INIS)

    Weichselgartner, H.

    1991-01-01

    This paper describes the development of an in-situ decontamination procedure by applying onto the contaminated surface (in an one-step or multi-step process) pasty, chemically aggressive agents causing dilution and adsorption of the contaminant and then hardening to form a strippable foil. The use of such a foil will result in following advantages, with respect to usual techniques: - sensibly shorter operation duration resulting in lower personnel doses; - reduction of the arising secondary waste volume because there is no need for washing; the volume of the spent strippable foil is much smaller than currently used water volumes; - optimal conditioning of the radioactive waste due to its fixation in a solid (foil); - an accidental contamination in a controlled area can easily be fixed and covered avoiding its propagation

  5. Practical and research aspects of beam-foil spectroscopy

    International Nuclear Information System (INIS)

    Bashkin, S.

    1975-01-01

    The application of a heavy-ion accelerator to research in beam-foil spectroscopy requires certain capital equipment which is somewhat unorthodox when viewed from the standpoint of conventional, low-energy nuclear physics. It is necessary that people who wish to expand their accelerator work to include beam-foil studies understand the nature and cost of such major apparatus. We will survey the equipment needs, starting with the particle analyzer at the output of the accelerator and including the equipment used in a variety of beam-foil experiments. Electronic and computer devices will not be discussed since they are essentially identical with those employed in nuclear studies. Considerable attention will be given to optical spectrometers and spectographs including simple instruments which might be used by a laboratory just getting started in beam-foil research, or which has limited financial resources. Attention will be given to the production and use of the exciter foils. We will then discuss some typical beam-foil experiments having to do with the excitation, detection, and analysis of spectral lines from electronic levels in multiply-ionized atoms, and also with the measurement of the mean lives of such levels. Finally, we will review some of the special properties of the beam-foil light source as regards the population of the magnetic sub-states of a given level. Recent work on the character of the emitted light will be presented. That work will deal specifically with the origin of the polarization of the light. The relevant experiments involve varying the angle between the plane of the exciter foil and the particle velocity. (author)

  6. Alignment and orientation effects in beam-foil experiments

    International Nuclear Information System (INIS)

    Band, Y.B.

    1975-01-01

    A theory of the orientation and alignment of atoms observed upon emergence from tilted foils is presented. The interaction with the foil surface is taken into account in the production process of particular states. Once they are produced, the evolution of these states, under the influence of the residual field near the surface, is calculated in the fashion introduced by Eck. The most general effect of this evolution is presented

  7. Electrospray ionization with aluminum foil: A versatile mass spectrometric technique.

    Science.gov (United States)

    Hu, Bin; So, Pui-Kin; Yao, Zhong-Ping

    2014-03-19

    In this study, we developed a novel electrospray ionization (ESI) technique based on household aluminum foil (Al foil) and demonstated the desirable features and applications of this technique. Al foil can be readily cut and folded into desired configuration for effective ionization and for holding sample solution in bulk to allowing acquisition of durable ion signals. The present technique was demonstrated to be applicable in analysis of a wide variety of samples, ranging from pure chemical and biological compounds, e.g., organic compounds and proteins, to complex samples in liquid, semi-solid, and solid states, e.g., beverages, skincare cream, and herbal medicines. The inert, hydrophobic and impermeable surface of Al foil allows convenient and effective on-target extraction of solid samples and on-target sample clean-up, i.e., removal of salts and detergents from proteins and peptides, extending ESI device from usually only for sample loading and ionization to including sample processing. Moreover, Al foil is an excellent heat-conductor and highly heat-tolerant, permitting direct monitoring of thermal reactions, e.g., thermal denaturation of proteins. Overall, the present study showed that Al-foil ESI could be an economical and versatile method that allows a wide range of applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Occlusal stability in shortened dental arches.

    Science.gov (United States)

    Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F

    2001-02-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.

  9. Vertex occlusal radiography in localizing unerupted mesiodentes

    Directory of Open Access Journals (Sweden)

    P Chalakkal

    2011-01-01

    Full Text Available The aim was to compare the vertex occlusal projection with the anterior maxillary occlusal projection in localizing the position of mesiodentes. Mesiodentes were observed in an 8-year-old boy with an anterior maxillary occlusal radiograph. A vertex occlusal radiograph was taken to compare it with the former in terms of mesiodentes localization with respect to the maxillary central incisors. The vertex occlusal radiograph provided greater details of the position and proximity of mesiodentes with respect to the long axis of maxillary central incisors in comparison to the anterior maxillary occlusal radiograph. Vertex occlusal radiography is an important diagnostic tool in diagnosing the presence, position, and proximity of mesiodentes with respect to the long axis of normally aligned maxillary central incisors. However, it is not recommended for routine use in a patient as its radiation dose is higher than conventional intraoral radiographic methods.

  10. Retinal vein occlusion: current treatment.

    Science.gov (United States)

    Lattanzio, Rosangela; Torres Gimeno, Ana; Battaglia Parodi, Maurizio; Bandello, Francesco

    2011-01-01

    Retinal vein occlusion (RVO) is a pathology noted for more than 150 years. Although a lot has been written on the matter, it is still a frequent condition with multifactorial etiopathogenesis with many unclear aspects. The RVO pathogenesis has varied systemic and local implications that make it difficult to elaborate treatment guidelines. The management of the patient with RVO is very complex and a multidisciplinary approach is required in order to identify and correct the associated risk factors. Laser therapy remains the gold standard in RVO, but only modest functional improvement has been shown in branch retinal occlusion forms. Multicenter studies of intravitreal drugs present them as an option to combine with laser. Anti-vascular endothelial growth factor, corticosteroids and sustained-release implants are the future weapons to stop disease progression and get a better visual outcome. Consequently, it is useful to clarify some aspects of the pathology that allow a better patient management. Copyright © 2010 S. Karger AG, Basel.

  11. Cannabis, Collaterals, and Coronary Occlusion

    Directory of Open Access Journals (Sweden)

    Kalpa De Silva

    2011-01-01

    Full Text Available A 51-year-old gentleman, who regularly smoked cannabis, presented with chest pain and diaphoresis. He was haemodynamically stable. ECG showed ST depression, inferiorly, and 1 mm ST elevation in lead aVR. Emergent coronary angiography showed thrombotic occlusion of the left main coronary artery (LMCA, the dominant RCA provided Rentrop grade II collaterals to the LAD. The LMCA was successfully reopened by deployment of a bare-metal stent. Animal heart models suggest that endogenous cannibinoids may cause ischaemic preconditioning. This case suggests that the severity of ischaemia, and hence ECG changes and haemodynamic consequences following an acute occlusion of the LMCA, can be ameliorated by coronary collateralisation and possibly by preconditioning of the myocardium.

  12. Performance of Simple Gas Foil Thrust Bearings in Air

    Science.gov (United States)

    Bruckner, Robert J.

    2012-01-01

    Foil bearings are self-acting hydrodynamics devices used to support high speed rotating machinery. The advantages that they offer to process fluid lubricated machines include: high rotational speed capability, no auxiliary lubrication system, non-contacting high speed operation, and improved damping as compared to rigid hydrodynamic bearings. NASA has had a sporadic research program in this technology for almost 6 decades. Advances in the technology and understanding of foil journal bearings have enabled several new commercial products in recent years. These products include oil-free turbochargers for both heavy trucks and automobiles, high speed electric motors, microturbines for distributed power generation, and turbojet engines. However, the foil thrust bearing has not received a complimentary level of research and therefore has become the weak link of oil-free turbomachinery. In an effort to both provide machine designers with basic performance parameters and to elucidate the underlying physics of foil thrust bearings, NASA Glenn Research Center has completed an effort to experimentally measure the performance of simple gas foil thrust bearing in air. The database includes simple bump foil supported thrust bearings with full geometry and manufacturing techniques available to the user. Test conditions consist of air at ambient pressure and temperatures up to 500 C and rotational speeds to 55,000 rpm. A complete set of axial load, frictional torque, and rotational speed is presented for two different compliant sub-structures and inter-pad gaps. Data obtained from commercially available foil thrust bearings both with and without active cooling is presented for comparison. A significant observation made possible by this data set is the speed-load capacity characteristic of foil thrust bearings. Whereas for the foil journal bearing the load capacity increases linearly with rotational speed, the foil thrust bearing operates in the hydrodynamic high speed limit. In

  13. Arterial occlusive disease after radiotherapy

    International Nuclear Information System (INIS)

    Piedbois, P.; Mazeron, J.J.; Le Bourgeois, J.P.; Becquemin, J.P.; Blanc, I.; Lange, F.; Melliere, D.

    1990-01-01

    Fourteen cases of arterial occlusion or severe narrowing following radiotherapy are studied in order to assess the possible etiological role of such therapy in arterial lesion. Surgical results are also discussed in terms of long-term efficacy. The average time of occurrence after radiotherapy was 8 years post-radiotherapy. This series includes 7 supra-aortic trunk stenoses and 7 abdominal aorta trunk stenoses. The doses received in the volumes iradiated ranged from 47 to 70 Gy with standard fractionation. Association of atherosclerotic risk factors was present in 12 patients, but stenoses were usually confined to irradiated areas, and at imes occurred in uncommon sites. Surgical management included 11 by-passes, 2 endarterectomies and one percutaneous transluminal angioplasty. All patients experienced immediate and satisfactory functional improvements. Three patients were re-operated on because of the re-occlusion of the by-pass and graft infection. On the whole, stenoses in previously irradiated areas showed no particular difficulties for surgical treatment. It was concluded that radiotherapy seems to be a definite risk factor for arterial occlusion or narrowing, especially in association in association with atherosclerotic risk factors. (author). 45 refs.; 3 figs.; 2 tabs

  14. Occlusal status among Yemeni children

    Directory of Open Access Journals (Sweden)

    Nabil M Al-Zubair

    2014-01-01

    Full Text Available Objectives: The purpose of this study was to assess the occlusal status in schoolchildren in Yemen, and to compare the results with those of other studies. Materials and Methods: The sample for this epidemiological survey consisted of 3003 primary school students, half of whom were boys and the other half girls, aged 12 years. The subjects were randomly selected, and none had received previous orthodontic treatment. Variables examined included intra-arch irregularities and malalignment (crowding and spacing in the incisal segments of the arch and midline diastema and discrepancies in occlusal contact relationship (maxillary overjet, mandibular overjet, anterior openbite and antero-posterior molar relation. Results: The results showed that about 26.1% of the subjects were still in the late mixed dentition stage and 73.9% presented with a dentition in the early permanent stage. Normal overjet was found in 55% of the sample. Crowding was observed in 31.4% of the subjects and midline diastema in 14.2%. Conclusion: Occlusal status among Yemeni children was characterized by a relatively high frequency of dental crowding, as well as a relatively high frequency of anterior mandibular overjet (Class III malocclusions.

  15. Computerized Angiographic Occlusion Rating for Ruptured Clipped Aneurysms is Superior to Subjective Occlusion Rating.

    Science.gov (United States)

    Al-Schameri, A R; Baltsavias, G; Winkler, P; Lunzer, M; Kral, M; Machegger, L; Weymayr, F; Emich, S; Sherif, C; Richling, B

    2015-09-01

    The computerized occlusion rating to estimate angiographic occlusion of embolized aneurysms is superior to the subjective occlusion rating. In this study, we compared the 2 methods in the analysis of aneurysms clipped after subarachnoid hemorrhage. The pre- and postoperative angiographic images (DSA) of 95 selected patients were analyzed and stratified in 4 grades (grade 0 for 100%, grade I for rating and the computerized (angiographic) occlusion rating. For the subjective occlusion rating, the occlusion rate was estimated; for the computerized occlusion rating, the "occluded" and "nonoccluded" aneurysm areas were automatically calculated in square millimeters after outlining the ideal occlusion line. With the subjective occlusion rating, 75 (78.9%), 12 (12.6%), 7 (7.4%), and 1 (1.1%) and with the computerized occlusion rating 45 (47.4%), 24 (25.3%), 20 (21.0%), and 6 (6.3%) patients had aneurysms stratified to grades 0, I, II and III, respectively. The interobserver variation was significant with the subjective occlusion rating but not with the computerized occlusion rating. The subjective occlusion rating overestimated aneurysm occlusion in 30 (31.6%) patients. Mean values were the following: subjective occlusion rating of 97.5 ± 6.3% and computerized occlusion rating of 93.5 ± 9.7%; P = rating: χ(2), 29.65; P rating: χ(2), 35.57, P rates of clipped aneurysms. The clearly lower interobserver variation of the computerized versus subjective occlusion rating may indicate a superiority of the computerized occlusion rating. © 2015 by American Journal of Neuroradiology.

  16. Development and preparation of thin, supported targets and stripper foils

    International Nuclear Information System (INIS)

    Aaron, W.S.; Petek, M.; Zevenbergen, L.A.; Gibson, J.R.

    1989-01-01

    Usually, it is desirable to prepare thin films that are self-supporting so that any extraneous support materials will not interfere with experimental measurements. However, films with very low areal densities, films other than metals or films covering large areas may require the use of a backing or support. Two classes of supported thin films are being developed by the Isotope Research Materials Laboratory (IRML). Electrodeposition of oxide thin films is a fairly common target preparation technique that is usually performed on backings such as thin metal foils or low atomic number materials like Be and to a lesser extent, C foils. Techniques have been developed by IRML that result in electrodeposition of oxide films up to 500 μg/cm 2 on carbon foils or aluminized mylar. Electrodeposition is a very attractive target fabrication method since it is very efficient in the usage of rare and/or valuable isotopes. The ability to prepare these films on carbon or mylar foils provides a target that has, in most applications, far less interference resulting from the backing. Thin films of carbon, aluminum, boron and titanium are being used as stripper foils in the generation of neutral (H - →H 0 ) particle beams with energies of 50 MeV or greater. Neutralizer foils as large as 25 cm x 25 cm have been prepared from Al and C in thicknesses ranging from 5 to 12 μg/cm 2 that are mounted on thin nickel grids with a transmittance of approximately 90%. Significantly larger foils are currently under development. (orig.)

  17. Interaction of relativistic H- ions with thin foils

    International Nuclear Information System (INIS)

    Mohagheghi, A.H.

    1990-09-01

    The response of relativistic H - ions to thin carbon foils was investigated for beam energies ranging from 226 MeV to 800 MeV. For the foil thicknesses we have studied, ranging from 15 to 300 μg/cm 2 , an appreciable fraction of the H - beam survives intact, some H - ions are stripped down to protons, and the remainder is distributed over the states of H 0 . This experiment is different from the low energy studies in that the projectile velocity is comparable to the speed of light, leading to an interaction time of typically less than a femtosecond. The present results challenge the theoretical understanding of the interaction mechanisms. An electron spectrometer was used to selectively field-ionize the Rydberg states, 9 < n < 17, at beam energies of 581 MeV and 800 MeV. The yield of low-lying states were measured by Doppler tuning a Nd:YAG laser to excite transitions to a Rydberg state which was then field-ionized and detected. A simple model is developed to fit the yield of each state as a function of foil thickness. The simple model is successful in predicting the general features of the yield data. However, the data are suggestive of a more complex structure in the yield curves. The yield of a given state depends strongly on the foil thickness, demonstrating that the excited states are formed during the passage of the ions through a foil. The optimum thickness to produce a given state increases with the principal quantum number of the state suggesting an excitation process which is at least pratially stepwise. The results of a Monte Carlo simulation are compared with the experimental data to estimate the distribution of the excited states coming out of a foil. The distributions of the excited states and their dependence on foil thickness are discussed

  18. Determination of the occlusal plane using a custom-made occlusal plane analyzer: a clinical report.

    Science.gov (United States)

    Bedia, Sumit V; Dange, Shankar P; Khalikar, Arun N

    2007-11-01

    In fixed prosthodontic procedures, when it has been determined that restoration of all or most of the posterior teeth is necessary, the use of the Broderick occlusal plane analyzer provides an easy and practical method to determine an occlusal plane that will fulfill esthetic and functional occlusion requirements. However, several manufacturers of semiadjustable articulators offer no such occlusal plane analyzers for use with these instruments. This article demonstrates the use of a custom-made Broderick occlusal plane analyzer with a semiadjustable articulator to determine the correct curve of Spee for the occlusal plane.

  19. Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.

  20. An Experimental Study on Micro Clinching of Metal Foils with Cutting by Laser Shock Forming.

    Science.gov (United States)

    Wang, Xiao; Li, Cong; Ma, Youjuan; Shen, Zongbao; Sun, Xianqing; Sha, Chaofei; Gao, Shuai; Li, Liyin; Liu, Huixia

    2016-07-13

    This paper describes a novel technique for joining similar and dissimilar metal foils, namely micro clinching with cutting by laser shock forming. A series of experiments were conducted to study the deformation behavior of single layer material, during which many important process parameters were determined. The process window of the 1060 pure aluminum foils and annealed copper foils produced by micro clinching with cutting was analyzed. Moreover, similar material combination (annealed copper foils) and dissimilar material combination (1060 pure aluminum foils and 304 stainless steel foils) were successfully achieved. The effect of laser energy on the interlock and minimum thickness of upper foils was investigated. In addition, the mechanical strength of different material combinations joined by micro clinching with cutting was measured in single lap shearing tests. According to the achieved results, this novel technique is more suitable for material combinations where the upper foil is thicker than lower foil. With the increase of laser energy, the interlock increased while the minimum thickness of upper foil decreased gradually. The shear strength of 1060 pure aluminum foils and 304 stainless steel foils combination was three times as large as that of 1060 pure aluminum foils and annealed copper foils combination.

  1. An Experimental Study on Micro Clinching of Metal Foils with Cutting by Laser Shock Forming

    Directory of Open Access Journals (Sweden)

    Xiao Wang

    2016-07-01

    Full Text Available This paper describes a novel technique for joining similar and dissimilar metal foils, namely micro clinching with cutting by laser shock forming. A series of experiments were conducted to study the deformation behavior of single layer material, during which many important process parameters were determined. The process window of the 1060 pure aluminum foils and annealed copper foils produced by micro clinching with cutting was analyzed. Moreover, similar material combination (annealed copper foils and dissimilar material combination (1060 pure aluminum foils and 304 stainless steel foils were successfully achieved. The effect of laser energy on the interlock and minimum thickness of upper foils was investigated. In addition, the mechanical strength of different material combinations joined by micro clinching with cutting was measured in single lap shearing tests. According to the achieved results, this novel technique is more suitable for material combinations where the upper foil is thicker than lower foil. With the increase of laser energy, the interlock increased while the minimum thickness of upper foil decreased gradually. The shear strength of 1060 pure aluminum foils and 304 stainless steel foils combination was three times as large as that of 1060 pure aluminum foils and annealed copper foils combination.

  2. Smooth nylon foil (SupraFOIL) orbital implants in orbital fractures: a case series of 181 patients.

    Science.gov (United States)

    Park, D J John; Garibaldi, Daniel C; Iliff, Nicholas T; Grant, Michael P; Merbs, Shannath L

    2008-01-01

    The SupraFOIL smooth nylon foil implant is a polyamide sheet available in varying thicknesses that has been used in orbital reconstruction following trauma. The authors report their experience with smooth nylon foil implants in the repair of orbital fractures. A retrospective chart review of patients having undergone repair of orbital fractures between January 1, 1995 and December 31, 2003 was conducted. The Wilcoxon test was used to compare cases with complications and those with no complications. Of 282 orbits that underwent fracture repair with alloplastic material, 87 were excluded because non-nylon foil implants were used alone or in combination with nylon foil to repair the orbital fracture. An additional 14 fractures were excluded because of insufficient clinical data or lack of follow-up, for a total of 181 orbits that underwent orbital fracture repair with only nylon foil. A transconjunctival approach was used in 98% cases, and all 181 implants were fixated with at least 1 titanium screw. Average follow-up was 362.8 days. The overall complication rate was 1.7%. One patient had an acute postoperative orbital hemorrhage (0.6% acute complication rate). Two patients had late orbital infections, 683 days and 984 days following repair (1.1% late complication rate). The authors found the smooth nylon foil implant to be safe and effective in orbital fracture repair. The lower rate of complications the authors observed compared with previously reported series may be related to implant fixation. A titanium screw secured just posterior to the orbital rim may decrease long-term complications by providing more stability than implants left without fixation.

  3. Gas Foil Bearings for Space Propulsion Nuclear Electric Power Generation

    Science.gov (United States)

    Howard, Samuel A.; DellaCorte, Christopher

    2006-01-01

    The choice of power conversion technology is critical in directing the design of a space vehicle for the future NASA mission to Mars. One candidate design consists of a foil bearing supported turbo alternator driven by a helium-xenon gas mixture heated by a nuclear reactor. The system is a closed-loop, meaning there is a constant volume of process fluid that is sealed from the environment. Therefore, foil bearings are proposed due to their ability to use the process gas as a lubricant. As such, the rotor dynamics of a foil bearing supported rotor is an important factor in the eventual design. The current work describes a rotor dynamic analysis to assess the viability of such a system. A brief technology background, assumptions, analyses, and conclusions are discussed in this report. The results indicate that a foil bearing supported turbo alternator is possible, although more work will be needed to gain knowledge about foil bearing behavior in helium-xenon gas.

  4. Dynamics and locomotion of flexible foils in a frictional environment

    Science.gov (United States)

    Wang, Xiaolin; Alben, Silas

    2018-01-01

    Over the past few decades, oscillating flexible foils have been used to study the physics of organismal propulsion in different fluid environments. Here, we extend this work to a study of flexible foils in a frictional environment. When the foil is oscillated by heaving at one end but is not free to locomote, the dynamics change from periodic to non-periodic and chaotic as the heaving amplitude increases or the bending rigidity decreases. For friction coefficients lying in a certain range, the transition passes through a sequence of N-periodic and asymmetric states before reaching chaotic dynamics. Resonant peaks are damped and shifted by friction and large heaving amplitudes, leading to bistable states. When the foil is free to locomote, the horizontal motion smoothes the resonant behaviours. For moderate frictional coefficients, steady but slow locomotion is obtained. For large transverse friction and small tangential friction corresponding to wheeled snake robots, faster locomotion is obtained. Travelling wave motions arise spontaneously, and move with horizontal speeds that scale as transverse friction coefficient to the power 1/4 and input power that scales as the transverse friction coefficient to the power 5/12. These scalings are consistent with a boundary layer form of the solutions near the foil's leading edge.

  5. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  6. [Form and position of occlusion plane in persons with physiological occlusion].

    Science.gov (United States)

    Lisova, T V; Slabkovskaia, A B; Persin, L S

    2006-01-01

    25 subjects aged 19-25 years with normal occlusion were assessed using radiographic and functional methods. Individual differences in occlusion plane form and position and dentofacial muscles functioning were established.

  7. Occlusal risk factors associated with temporomandibular disorders in young adults with normal occlusions.

    Science.gov (United States)

    Wang, Chen; Yin, Xinmin

    2012-10-01

    The aim of this study was to characterize occlusal stability in young adults with temporomandibular disorder (TMD). Thirty-one patients (aged 19-31 years) with complete natural dentition and Angle class I occlusion who exhibited TMD were compared with 31 age- and sex-matched healthy control subjects. The occlusal registrations were performed using the T-Scan II occlusal imaging and analysis system. Center of occlusal force, asymmetry index of occlusal force, maximal movement of COF, premature contacts, clusion time, and disclusion time were recorded. Compared with control subjects, TMD subjects had a significantly higher frequency of premature contacts (16/32, 50.0%) and greater bilateral asymmetry in the occlusal force. Furthermore, prolonged clusion time and disclusion time also were observed in TMD subjects. These results suggest that a significant association exists between occlusal stability and TMD in young adults. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Foil Bearing Coating Behavior in CO2

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Matthew [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Kruizenga, Alan Michael [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Pasch, James Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Fleming, Darryn [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    The Sandia S-CO2 Recompression Closed Brayton Cycle (RCBC) utilizes a series of gas foil bearings in its turbine-alternator-compressors. At high shaft rotational speed these bearings allow the shaft to ride on a cushion of air. Conversely, during startup and shutdown, the shaft rides along the foil bearing surface. Low-friction coatings are used on bearing surfaces in order to facilitate rotation during these periods. An experimental program was initiated to elucidate the behavior of coated bearing foils in the harsh environments of this system. A test configuration was developed enabling long duration exposure tests, followed by a range of analyses relevant to their performance in a bearing. This report provides a detailed overview of this work. The results contained herein provide valuable information in selecting appropriate coatings for more advanced future bearing-rig tests at the newly established test facility in Sandia-NM.

  9. Model-Based Optimization for Flapping Foil Actuation

    Science.gov (United States)

    Izraelevitz, Jacob; Triantafyllou, Michael

    2014-11-01

    Flapping foil actuation in nature, such as wings and flippers, often consist of highly complex joint kinematics which present an impossibly large parameter space for designing bioinspired mechanisms. Designers therefore often build a simplified model to limit the parameter space so an optimum motion trajectory can be experimentally found, or attempt to replicate exactly the joint geometry and kinematics of a suitable organism whose behavior is assumed to be optimal. We present a compromise: using a simple local fluids model to guide the design of optimized trajectories through a succession of experimental trials, even when the parameter space is too large to effectively search. As an example, we illustrate an optimization routine capable of designing asymmetric flapping trajectories for a large aspect-ratio pitching and heaving foil, with the added degree of freedom of allowing the foil to move parallel to flow. We then present PIV flow visualizations of the optimized trajectories.

  10. Compliant Foil Journal Bearings - Investigation of Dynamic Properties

    DEFF Research Database (Denmark)

    Larsen, Jon Steffen; Santos, Ilmar

    and dynamic coefficients, of the compliant foil bearing together with an efficient solution method, which can be easily adopted and implemented by mechanical engineers. A theoretical model of a radial compliant foil bearing that incorporates compressibility of the lubricating gas and flexibility...... a Bubnow-Galerkin approach. This constitutes the main original contribution of this work, considering the fact that the finite difference method is commonly used and thouroughly investigated in the literature. The finite element method leads to a set of non-linear equations for the static fluid film...... on the compliant foil bearings, and the understanding of their dynamic behaviour is growing. However, practical design involving these bearings are still associated with a large degree of trial and error. This study aims at establishing an accurate mathematical model, to calculate the pressure, film height...

  11. Acceleration of polyethelene foils by laser driven ablation

    International Nuclear Information System (INIS)

    Ahlstrom, H.G.; Burginyon, G.A.; Haas, R.A.

    1974-01-01

    The production of thermonuclear energy, by laser driven implosion of spherical DT shells, with achievable laser technology, requires the development of an efficient and stable implosion. Certain aspects of the acceleration of the spherical shells can be studied experimentally by irradiating thin, 5 to 25 μm, polyethelene foils. The results of foil acceleration experiments performed using a Nd:YAG-Glass laser capable of producing 150 J, 1 nsec pulses will be discussed. The dynamics of the accelerated foil, the ion blow off, high energy electron spectrum (6 to 180 keV), x-ray spectrum (1 to 150 keV) the spatial distribution of the x-ray emission, the laser beam focal spot energy distribution, the laser temporal pulse shape and spectrum for reflected and transmitted radiation have all been measured simultaneously. The results of these measurements are compared with detailed numerical simulations. (U.S.)

  12. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  13. Assessment of occlusion curriculum in predoctoral dental education: report from ACP Task Force on Occlusion Education.

    Science.gov (United States)

    Lee, Damian J; Wiens, Jonathan P; Ference, John; Donatelli, David; Smith, Rick M; Dye, Bryan D; Obrez, Ales; Lang, Lisa A

    2012-10-01

    The purposes of this report were to (1) assess the current occlusion curriculum in the predoctoral prosthodontic education of US dental institutions and (2) to examine the opinions of faculty, course directors, and program directors on the contents of occlusion curriculum. The Task Force on Occlusion Education from the American College of Prosthodontists (ACP) conducted two surveys using a web-based survey engine: one to assess the current status of occlusion education in predoctoral dental education and another to examine the opinions of faculty and course directors on the content of occlusion curriculum. The sections in the surveys included demographic information, general curriculum information, occlusion curriculum for dentate patients, occlusion curriculum for removable prosthodontics, occlusion curriculum for implant prosthodontics, temporomandibular disorder (TMD) curriculum, teaching philosophy, concepts taught, and methods of assessment. The results from the surveys were compiled and analyzed using descriptive statistics. The results from the two surveys on general concepts taught in occlusion curriculum were sorted and compared for discrepancies. According to the predoctoral occlusion curriculum surveys, canine guidance was preferred for dentate patients, fixed prosthodontics, and fixed implant prosthodontics. Bilateral balanced occlusion was preferred for removable prosthodontics and removable implant prosthodontics. There were minor differences between the two surveys regarding the occlusion concepts being taught and the opinions of faculty members teaching occlusion. Two surveys were conducted regarding the current concepts being taught in occlusion curriculum and the opinions of educators on what should be taught in occlusion curriculum. An updated and clearly defined curriculum guideline addressing occlusion in fixed prosthodontics, removable prosthodontics, implant prosthodontics, and TMD is needed. © 2012 by the American College of Prosthodontists.

  14. Transmission of fast molecular ions through thin foils

    International Nuclear Information System (INIS)

    Pietsch, W.J.; Gemmell, D.S.; Cooney, P.J.; Kanter, E.P.; Kurath, D.; Ratkowski, A.J.; Vager, Z.; Zabransky, B.J.

    1979-01-01

    New results on the transmission of fast molecular ions through thin foils are presented and a mechanism for the transmission process is proposed. The main feature of the postulated mechanism is that a finite fraction of the incident molecular beam does not undergo a strong Coulomb explosion while traversing the foil. Because the emerging fragments are at large internuclear separations, there is an enhanced probability for the formation of bound, long-range, excited electronic states following electron capture at the rear surface of the target

  15. Method and apparatus for tensile testing of metal foil

    Science.gov (United States)

    Wade, O. W. (Inventor)

    1976-01-01

    A method for obtaining accurate and reproducible results in the tensile testing of metal foils in tensile testing machines is described. Before the test specimen are placed in the machine, foil side edges are worked until they are parallel and flaw free. The specimen are also aligned between and secured to grip end members. An aligning apparatus employed in the method is comprised of an alignment box with a longitudinal bottom wall and two upright side walls, first and second removable grip end members at each end of the box, and a means for securing the grip end members within the box.

  16. Electrochemically replicated smooth aluminum foils for anodic alumina nanochannel arrays

    International Nuclear Information System (INIS)

    Biring, Sajal; Tsai, K-T; Sur, Ujjal Kumar; Wang, Y-L

    2008-01-01

    A fast electrochemical replication technique has been developed to fabricate large-scale ultra-smooth aluminum foils by exploiting readily available large-scale smooth silicon wafers as the masters. Since the adhesion of aluminum on silicon depends on the time of surface pretreatment in water, it is possible to either detach the replicated aluminum from the silicon master without damaging the replicated aluminum and master or integrate the aluminum film to the silicon substrate. Replicated ultra-smooth aluminum foils are used for the growth of both self-organized and lithographically guided long-range ordered arrays of anodic alumina nanochannels without any polishing pretreatment

  17. Non-Occlusive Mesenteric Ischemia

    International Nuclear Information System (INIS)

    Kraemer, S.C.; Universitaetsklinikum Ulm; Goerich, J.; Oertel, F.; Scheld, H.; Heindel, W.

    2003-01-01

    The so-called non-occlusive disease (NOD) or non-occlusive mesenteric ischemia (NOMI) is a severe and life-threatening pathology. Even under optimal circumstances and standardised diagnostic and therapeutic procedures maximum survival rates do not exceed 50%. The NOD is a pathology of the elder patient and its incidence rises with other comorbidities such as reduced cardiac output, diabetes and renal insufficiency. Induction of the disease with a severe vasoconstriction of the splanchnic vessels may be a simple cardiac decompensation, a frequent trigger however is a previous heart surgery with consecutive cardiac shock. Early diagnosis is difficult to conduct because of unspecific symptoms. Beside abdominal pain in awake patients, ileus or subileus is remaining the single acute symptom which could be also a consequence of a postoperative paralysis. Laboratory parameters such as leucocytosis and elevated lactat levels are often positive, but unspecific and the latter may be a delayed sign of progressive disease. The only sufficient method for diagnosis implicating a possible treatment option seems to be an immediate angiographic examination. Because of the disappointing results of a solitary surgical approach transarterial medication via catheter is indicated. Depending of the course of the disease only a combination of local mesenteric infusion of vasodilatory drugs and surgical resection of already necrotic bowel promises a successful therapeutic approach and better survival rates. (orig.) [de

  18. [Relationship between occlusal plane and masticatory path in youth with individual normal occlusion].

    Science.gov (United States)

    Lin, Xue-feng; Li, Shao-hua; Huang, Zhuo-shan; Wu, Xia-yi

    2010-06-01

    To investigate the characteristics of and relationship between occlusal plane and masticatory path in young adults with individual normal occlusion, and to provide clinical implications on both morphological and functional reference of occlusal plane location. Forty-three young adults with individual normal occlusion were included. Lateral projections of cephalometric radiographs were taken. The parameters of anatomical landmarks were analyzed. The BioEGN mandibular kinesiography analyzer was used to record the path of incisal edge of mandibular central incisor movement during mastication. The Pearson's linear correlation analysis was performed to analyze the relationship of inclination of occlusal plane and data mentioned above with SPSS13.0 software. The inclination of occlusal plane (the angle between occlusal plane and Camper's line OP-CP) was (2.1 ± 3.8)° in youth with normal occlusion. Means of maximal distances of 3-dimensional masticatory mandibular movement paths were as follow: the vertical length was (20.22 ± 4.28) mm, the anterior-posterior width was (11.42 ± 2.45) mm, and the lateral width was (8.62 ± 1.52) mm. The inclination of occlusal plane was negatively correlated to the lateral width of masticatory path in frontal plane (r = -0.39, P Occlusal plane was approximately vertical to the opening and closing path in the vicinity of intercuspal position during mastication. The inclination of occlusal plane was positively related to occlusal plane-closing angles in the upper segments of closing path during mastication (P occlusal plane (P > 0.05). These results suggest that the sagittal inclination of occlusal plane can influence 3-dimensional morphology of masticatory path.The inclination of occlusal plane has a guiding effect on masticatory movement in the upper segments of closing path.

  19. Performance of the carbon stripping foils in the Argonne FN tandem

    International Nuclear Information System (INIS)

    Den Hartog, P.K.; Munson, F.; Heath, C.; Thomas, G.

    1980-01-01

    Carbon stripping foils produced by the glow discharge cracking of ethylene were produced and the foils were tested in the Argonne FN tandem accelerator. The results are presented and the characteristics of stripping media are discussed

  20. Design, Fabrication and Performance of Open Source Generation I and II Compliant Hydrodynamic Gas Foil Bearings

    Science.gov (United States)

    DellaCorte, Christopher; Radil, Kevin C.; Bruckner, Robert J.; Howard, S. Adam

    2007-01-01

    Foil gas bearings are self-acting hydrodynamic bearings made from sheet metal foils comprised of at least two layers. The innermost top foil layer traps a gas pressure film that supports a load while a layer or layers underneath provide an elastic foundation. Foil bearings are used in many lightly loaded, high-speed turbo-machines such as compressors used for aircraft pressurization, and small micro-turbines. Foil gas bearings provide a means to eliminate the oil system leading to reduced weight and enhanced temperature capability. The general lack of familiarity of the foil bearing design and manufacturing process has hindered their widespread dissemination. This paper reviews the publicly available literature to demonstrate the design, fabrication and performance testing of both first and second generation bump style foil bearings. It is anticipated that this paper may serve as an effective starting point for new development activities employing foil bearing technology.

  1. A new modal-based approach for modelling the bump foil structure in the simultaneous solution of foil-air bearing rotor dynamic problems

    Science.gov (United States)

    Bin Hassan, M. F.; Bonello, P.

    2017-05-01

    Recently-proposed techniques for the simultaneous solution of foil-air bearing (FAB) rotor dynamic problems have been limited to a simple bump foil model in which the individual bumps were modelled as independent spring-damper (ISD) subsystems. The present paper addresses this limitation by introducing a modal model of the bump foil structure into the simultaneous solution scheme. The dynamics of the corrugated bump foil structure are first studied using the finite element (FE) technique. This study is experimentally validated using a purpose-made corrugated foil structure. Based on the findings of this study, it is proposed that the dynamics of the full foil structure, including bump interaction and foil inertia, can be represented by a modal model comprising a limited number of modes. This full foil structure modal model (FFSMM) is then adapted into the rotordynamic FAB problem solution scheme, instead of the ISD model. Preliminary results using the FFSMM under static and unbalance excitation conditions are proven to be reliable by comparison against the corresponding ISD foil model results and by cross-correlating different methods for computing the deflection of the full foil structure. The rotor-bearing model is also validated against experimental and theoretical results in the literature.

  2. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  3. Custom total occlusal convergence angle sticker fabrication.

    Science.gov (United States)

    Cho, Seok-Hwan; Nagy, William W

    2015-09-01

    This article describes a method of fabricating a custom total occlusal convergence angle sticker with photo editing software and label stickers. The custom total occlusal convergence angle sticker can help clinicians achieve an accurate degree of taper during axial wall reduction of tooth preparation. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Occlusal stability in shortened dental arches.

    NARCIS (Netherlands)

    Witter, D.J.; Creugers, N.H.J.; Kreulen, C.M.; Haan, A. de

    2001-01-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a

  5. The prevalence of questionable occlusal caries

    DEFF Research Database (Denmark)

    Makhija, Sonia K; Gilbert, Gregg H; Funkhouser, Ellen

    2012-01-01

    Questionable occlusal caries (QOC) can be defined as clinically suspected caries with no cavitation or radiographic evidence of occlusal caries. To the authors' knowledge, no one has quantified the prevalence of QOC, so this quantification was the authors' objective in conducting this study...

  6. Dose reader of dosimetric foil; Czytnik dawki folii dozymetrycznej

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.; Strzalkowski, J.; Smolko, K.

    1997-12-31

    Read out the absorbance of a dosimetric foil is accomplished by two beam spectrophotometer. Such a solution makes possible the compensation of light source instabilities and ensures higher stability of the dose reader. The error of absorbance measurement caused by the instabilities does not exceed 0.0004 A. (author). 3 refs, 3 figs.

  7. Tribalism as a Foiled Factor of Africa Nation-Building

    Science.gov (United States)

    Okogu, J. O.; Umudjere, S. O.

    2016-01-01

    This paper tends to examine tribalism as a foiled factor on Africa nation-building and proffers useful tips to salvaging the Africa land from this deadly social problem. Africans in times past had suffered enormous attacks, injuries, losses, deaths, destruction of properties and human skills and ideas due to the presence of tribalistic views in…

  8. Secret in the Margins: Rutherford's Gold Foil Experiment

    Science.gov (United States)

    Aydin, Sevgi; Hanuscin, Deborah L.

    2011-01-01

    In this article, the authors describe a lesson that uses the 5E Learning Cycle to help students not only understand the atomic model but also how Ernest Rutherford helped develop it. The lesson uses Rutherford's gold foil experiment to focus on three aspects of the nature of science: the empirical nature of science, the tentativeness of scientific…

  9. Foil Bearing Starting Considerations and Requirements for Rotorcraft Engine Applications

    Science.gov (United States)

    Radil, Kevin C.; DellaCorte, Christopher

    2009-01-01

    Foil gas bearings under development for rotorcraft-sized, hot core engine applications have been susceptible to damage from the slow acceleration and rates typically encountered during the pre-ignition stage in conventional engines. Recent laboratory failures have been assumed to be directly linked to operating foil bearings below their lift-off speed while following conventional startup procedures for the engines. In each instance, the continuous sliding contact between the foils and shaft was believed to thermally overload the bearing and cause the engines to fail. These failures highlight the need to characterize required acceleration rates and minimum operating speeds for these applications. In this report, startup experiments were conducted with a large, rotorcraft engine sized foil bearing under moderate load and acceleration rates to identify the proper start procedures needed to avoid bearing failure. The results showed that a bearing under a 39.4 kPa static load can withstand a modest acceleration rate of 500 rpm/s and excessive loitering below the bearing lift-off speed provided an adequate solid lubricant is present.

  10. The Visualization of Infrared Radiation Using Thermal Sensitive Foils

    Science.gov (United States)

    Bochnícek, Zdenek

    2013-01-01

    This paper describes a set of demonstration school experiments where infrared radiation is detected using thermal sensitive foils. The possibility of using standard glass lenses for infrared imaging is discussed in detail. It is shown that with optic components made from glass, infrared radiation up to 2.5 µm of wavelength can be detected. The…

  11. Evaluation of Alumina-Forming Austenitic Foil for Advanced Recuperators

    Energy Technology Data Exchange (ETDEWEB)

    Pint, Bruce A [ORNL; Brady, Michael P [ORNL; Yamamoto, Yukinori [ORNL; Santella, Michael L [ORNL; Maziasz, Philip J [ORNL; Matthews, Wendy [Capstone Turbines

    2011-01-01

    A corrosion- and creep-resistant austenitic stainless steel has been developed for advanced recuperator applications. By optimizing the Al and Cr contents, the alloy is fully austenitic for creep strength while allowing the formation of a chemically stable external alumina scale at temperatures up to 900 C. An alumina scale eliminates long-term problems with the formation of volatile Cr oxy-hydroxides in the presence of water vapor in exhaust gas. As a first step in producing foil for primary surface recuperators, three commercially cast heats have been rolled to 100 m thick foil in the laboratory to evaluate performance in creep and oxidation testing. Results from initial creep testing are presented at 675 C and 750 C, showing excellent creep strength compared with other candidate foil materials. Laboratory exposures in humid air at 650 800 C have shown acceptable oxidation resistance. A similar oxidation behavior was observed for sheet specimens of these alloys exposed in a modified 65 kW microturbine for 2871 h. One composition that showed superior creep and oxidation resistance has been selected for the preparation of a commercial batch of foil. DOI: 10.1115/1.4002827

  12. Factors affecting use of fission foils as dosimetry sensors

    International Nuclear Information System (INIS)

    Griffin, P.J.; Vehar, D.W.; Kelly, J.G.; Holm, C.V.

    1996-01-01

    Fission foils are commonly used as dosimetry sensors. They play a very important role in neutron spectrum determinations. This paper provides a combination of experimental measurements and calculations to quantify the importance and synergy of several factors that affect the fission response of a dosimeter. Only when these effects are properly treated can fission dosimeters be used with sufficient fidelity

  13. Validation of calculated self-shielding factors for Rh foils

    Science.gov (United States)

    Jaćimović, R.; Trkov, A.; Žerovnik, G.; Snoj, L.; Schillebeeckx, P.

    2010-10-01

    Rhodium foils of about 5 mm diameter were obtained from IRMM. One foil had thickness of 0.006 mm and three were 0.112 mm thick. They were irradiated in the pneumatic transfer system and in the carousel facility of the TRIGA reactor at the Jožef Stefan Institute. The foils were irradiated bare and enclosed in small cadmium boxes (about 2 g weight) of 1 mm thickness to minimise the perturbation of the local neutron flux. They were co-irradiated with 5 mm diameter and 0.2 mm thick Al-Au (0.1%) alloy monitor foils. The resonance self-shielding corrections for the 0.006 and 0.112 mm thick samples were calculated by the Monte Carlo simulation and amount to about 10% and 60%, respectively. The consistency of measurements confirmed the validity of self-shielding factors. Trial estimates of Q0 and k0 factors for the 555.8 keV gamma line of 104Rh were made and amount to 6.65±0.18 and (6.61±0.12)×10 -2, respectively.

  14. Dynamic environmental control mechanisms for pneumatic foil constructions

    Science.gov (United States)

    Flor, Jan-Frederik; Wu, Yupeng; Beccarelli, Paolo; Chilton, John

    2017-11-01

    Membrane and foil structures have become over the last decades an attractive alternative to conventional materials and building systems with increasing implementation in different typologies and scale. The development of transparent, light, flexible and resistant materials like Ethylene Tetrafluoroethylene (ETFE) has triggered a rethinking of the building envelope in the building industry towards lightweight systems. ETFE foil cushions have proven to fulfil the design requirements in terms of structural efficiency and aesthetic values. But the strategies to satisfy increasing demands of energy efficiency and comfort conditions are still under development. The prediction and manipulation of the thermo-optical behaviour of ETFE foil cushion structures currently remain as one of the main challenges for designers and manufacturers. This paper reviews ongoing research regarding the control of the thermo-optical performance of ETFE cushion structures and highlights challenges and possible improvements. An overview of different dynamic and responsive environmental control mechanisms for multilayer foil constructions is provided and the state of the art in building application outlined by the discussion of case studies.

  15. Aortoiliac occlusive disease masquerading as cerebrovascular accident

    Directory of Open Access Journals (Sweden)

    Nandeesh B

    2007-01-01

    Full Text Available Acute aortoiliac occlusion is an unusual but potentially catastrophic condition causing acute limb ischemia and associated with early and high rates of mortality and morbidity. It is caused by either embolic occlusion of the infra renal aorta at the bifurcation or beyond or thrombosis of the abdominal aorta and its large terminal branches. Neurological symptoms are rare manifestation of acute aortoiliac occlusion and when neurological symptoms predominate, patients are mistakenly considered to have cerebrovascular event. We present a 60-year-old man with atherosclerotic thrombotic occlusion of the left common iliac artery causing acute painful monoplegia. We mistook the acute monoplegia due to acute limb ischemia for cerebrovascular accident. Pathologic examination revealed a firm thrombus occluding the origin of left common iliac artery and extending along the length of the vessel. Acute aortic iliac occlusion can masquerade as a cerebrovascular stroke and a thorough clinical evaluation and imaging studies allow early diagnosis and instituting life-saving treatment timely.

  16. [Occlusal vertical dimension in removable complete dentures].

    Science.gov (United States)

    den Haan, R; Witter, D J

    2011-12-01

    In removable complete dentures, the occlusal vertical dimension is an important factor for patients' satisfaction with aesthetics. An excessively reduced occlusal vertical dimension is especially likely to lead to complaints about aesthetics, whereas an increased occlusal vertical dimension may lead to discomfort and a decision not to wear the complete dentures. There are various methods for determining the occlusal vertical dimension in complete dentures, based on the vertical dimension in the rest position of the mandible or on phonetics. However, none of the methods have proven to be clearly superior, in terms of reliability, than the others. The assessment of the occlusal vertical dimension will become more reliable if several methods are used simultaneously. Moreover, knowledge of the characteristics of the ageing face is essential.

  17. Method and apparatus for coating thin foil with a boron coating

    Energy Technology Data Exchange (ETDEWEB)

    Lacy, Jeffrey L.

    2018-01-16

    An apparatus and a process is disclosed for applying a boron coating to a thin foil. Preferably, the process is a continuous, in-line process for applying a coating to a thin foil comprising wrapping the foil around a rotating and translating mandrel, cleaning the foil with glow discharge in an etching chamber as the mandrel with the foil moves through the chamber, sputtering the foil with boron carbide in a sputtering chamber as the mandrel moves through the sputtering chamber, and unwinding the foil off the mandrel after it has been coated. The apparatus for applying a coating to a thin foil comprises an elongated mandrel. Foil preferably passes from a reel to the mandrel by passing through a seal near the initial portion of an etching chamber. The mandrel has a translation drive system for moving the mandrel forward and a rotational drive system for rotating mandrel as it moves forward. The etching chamber utilizes glow discharge on a surface of the foil as the mandrel moves through said etching chamber. A sputtering chamber, downstream of the etching chamber, applies a thin layer comprising boron onto the surface of the foil as said mandrel moves through said sputtering chamber. Preferably, the coated foil passes from the mandrel to a second reel by passing through a seal near the terminal portion of the sputtering chamber.

  18. Low-energy electron beams through ultra-thin foils, applications for electron microscopy

    NARCIS (Netherlands)

    Van Aken, R.H.

    2005-01-01

    This thesis has discussed two electron microscopy applications that make use of ultra-thin foils: the tunnel junction emitter and the low-energy foil corrector. Both applications have in common that the electron beam is sent through the thin foil at low energy. Part of the electrons will scatter in

  19. 78 FR 28577 - Notification of Proposed Production Activity, LLFlex, LLC, Subzone 29J (Foil Backed Paperboard...

    Science.gov (United States)

    2013-05-15

    ... Foreign-Trade Zones Board Notification of Proposed Production Activity, LLFlex, LLC, Subzone 29J (Foil...) was received on May 6, 2013. The subzone currently has authority to produce aluminum foil liner stock. The current request would add foil backed paperboard to the list of approved finished products...

  20. Wake visualization of a heaving and pitching foil in a soap film

    NARCIS (Netherlands)

    Muijres, F.T.; Lentink, D.

    2007-01-01

    Many fish depend primarily on their tail beat for propulsion. Such a tail is commonly modeled as a two-dimensional flapping foil. Here we demonstrate a novel experimental setup of such a foil that heaves and pitches in a soap film. The vortical flow field generated by the foil correlates with

  1. Occlusion for stimulus deprivation amblyopia

    Science.gov (United States)

    Antonio-Santos, Aileen; Vedula, Satyanarayana S; Hatt, Sarah R; Powell, Christine

    2014-01-01

    Background Stimulus deprivation amblyopia (SDA) develops due to an obstruction to the passage of light secondary to a condition such as cataract. The obstruction prevents formation of a clear image on the retina. SDA can be resistant to treatment, leading to poor visual prognosis. SDA probably constitutes less than 3% of all amblyopia cases, although precise estimates of prevalence are unknown. In developed countries, most patients present under the age of one year; in less developed parts of the world patients are likely to be older at the time of presentation. The mainstay of treatment is removal of the cataract and then occlusion of the better-seeing eye, but regimens vary, can be difficult to execute, and traditionally are believed to lead to disappointing results. Objectives Our objective was to evaluate the effectiveness of occlusion therapy for SDA in an attempt to establish realistic treatment outcomes. Where data were available, we also planned to examine evidence of any dose response effect and to assess the effect of the duration, severity, and causative factor on the size and direction of the treatment effect. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), the Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to October 2013), PubMed (January 1946 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 28 October 2013. Selection criteria We planned

  2. Functional Aesthetic Occlusal Plane (FAOP

    Directory of Open Access Journals (Sweden)

    Carlos Alexandre Câmara

    Full Text Available ABSTRACT Introduction: A reasonable exposure of incisors and gingival tissues is generally considered more attractive than excess or lack of exposure. A reasonable gingival exposure is considered to be around 0 to 2 mm when smiling and 2-4 mm exposure of the maxillary incisor edge when the lips are at rest. Objective: The aim of this paper is to present the Functional Aesthetic Occlusal Plane (FAOP, which aims to help in the diagnosis of the relationships established among molars, incisors and the upper lip. Conclusion: FAOP can complement an existing and established orthodontic treatment plan, facilitating the visualization of functional and aesthetic demands by giving a greater focus on the position of incisors in the relationship established among the incisors, molars and the upper lip stomion.

  3. Functional Aesthetic Occlusal Plane (FAOP).

    Science.gov (United States)

    Câmara, Carlos Alexandre; Martins, Renato Parsekian

    2016-01-01

    A reasonable exposure of incisors and gingival tissues is generally considered more attractive than excess or lack of exposure. A reasonable gingival exposure is considered to be around 0 to 2 mm when smiling and 2-4 mm exposure of the maxillary incisor edge when the lips are at rest. The aim of this paper is to present the Functional Aesthetic Occlusal Plane (FAOP), which aims to help in the diagnosis of the relationships established among molars, incisors and the upper lip. FAOP can complement an existing and established orthodontic treatment plan, facilitating the visualization of functional and aesthetic demands by giving a greater focus on the position of incisors in the relationship established among the incisors, molars and the upper lip stomion.

  4. Numerical studies on the interaction between two parallel D-cylinder and oscillated foil

    Science.gov (United States)

    Chao, Li-Ming; Zhang, Dong; Cao, Yong-Hui; Pan, Guang

    2018-02-01

    To understand the interaction between the oscillated body and oncoming vortex, some numerical studies have been conducted on a system including two parallel D-cylinder and one oscillated foil in this paper. It is found that the distance between parallel D-cylinder and oscillated foil would play a key role in affecting the change regulation of thrust generation of oscillated foil, and the kinematics of oscillated foil would determine the value of propulsive thrust, the gap between two parallel D-cylinder would only affect the hydrodynamic performance of oscillated foil at intermediate conditions.

  5. Studies of PMMA sintering foils with and without coating by magnetron sputtering Pd

    Science.gov (United States)

    Cutroneo, M.; Mackova, A.; Torrisi, L.; Vad, K.; Csik, A.; Ando', L.; Svecova, B.

    2017-09-01

    Polymethylmethacrylate thin foils were prepared by using physical and chemical processes aimed at changing certain properties. The density and the optical properties were changed obtaining clear and opaque foils. DC magnetron sputtering method was used to cover the foils with thin metallic palladium layers. The high optical absorbent foils were obtained producing microstructured PMMA microbeads with and without thin metallic coatings. Rutherford Backscattering Spectroscopy, optical investigation and microscopy were employed to characterize the prepared foils useful in the field study of laser-matter interaction.

  6. Measurements of laser generated soft X-ray emission from irradiated gold foils

    Energy Technology Data Exchange (ETDEWEB)

    Davis, J. S.; Keiter, P. A.; Klein, S. R.; Drake, R. P.; Shvarts, D. [University of Michigan, 2455 Hayward St., Ann Arbor, Michigan 48109 (United States); Frank, Y.; Raicher, E.; Fraenkel, M. [Soreq Nuclear Research Center, Yavne (Israel)

    2016-11-15

    Soft x-ray emission from laser irradiated gold foils was measured at the Omega-60 laser system using the Dante photodiode array. The foils were heated with 2 kJ, 6 ns laser pulses and foil thicknesses were varied between 0.5, 1.0, and 2.0 μm. Initial Dante analysis indicates peak emission temperatures of roughly 100 eV and 80 eV for the 0.5 μm and 1.0 μm thick foils, respectively, with little measurable emission from the 2.0 μm foils.

  7. Dual scattering foil design for poly-energetic electron beams.

    Science.gov (United States)

    Kainz, K K; Antolak, J A; Almond, P R; Bloch, C D; Hogstrom, K R

    2005-03-07

    The laser wakefield acceleration (LWFA) mechanism can accelerate electrons to energies within the 6-20 MeV range desired for therapy application. However, the energy spectrum of LWFA-generated electrons is broad, on the order of tens of MeV. Using existing laser technology, the therapeutic beam might require a significant energy spread to achieve clinically acceptable dose rates. The purpose of this work was to test the assumption that a scattering foil system designed for a mono-energetic beam would be suitable for a poly-energetic beam with a significant energy spread. Dual scattering foil systems were designed for mono-energetic beams using an existing analytical formalism based on Gaussian multiple-Coulomb scattering theory. The design criterion was to create a flat beam that would be suitable for fields up to 25 x 25 cm2 at 100 cm from the primary scattering foil. Radial planar fluence profiles for poly-energetic beams with energy spreads ranging from 0.5 MeV to 6.5 MeV were calculated using two methods: (a) analytically by summing beam profiles for a range of mono-energetic beams through the scattering foil system, and (b) by Monte Carlo using the EGS/BEAM code. The analytic calculations facilitated fine adjustments to the foil design, and the Monte Carlo calculations enabled us to verify the results of the analytic calculation and to determine the phase-space characteristics of the broadened beam. Results showed that the flatness of the scattered beam is fairly insensitive to the width of the input energy spectrum. Also, results showed that dose calculated by the analytical and Monte Carlo methods agreed very well in the central portion of the beam. Outside the useable field area, the differences between the analytical and Monte Carlo results were small but significant, possibly due to the small angle approximation. However, these did not affect the conclusion that a scattering foil system designed for a mono-energetic beam will be suitable for a poly

  8. Simultaneous laser cutting and welding of metal foil to edge of a plate

    Science.gov (United States)

    Pernicka, John C.; Benson, David K.; Tracy, C. Edwin

    1996-01-01

    A method of welding an ultra-thin foil to the edge of a thicker sheet to form a vacuum insulation panel comprising the steps of providing an ultra-thin foil having a thickness less than 0.002, providing a top plate having an edge and a bottom plate having an edge, clamping the foil to the edge of the plate wherein the clamps act as heat sinks to distribute heat through the foil, providing a laser, moving the laser relative to the foil and the plate edges to form overlapping weld beads to weld the foil to the plate edges while simultaneously cutting the foil along the weld line formed by the overlapping beads.

  9. A Study on Growth and Development of Dentition and Occlusion in Children : Changes of Occlusion

    OpenAIRE

    Kaihara, Yasutaka; Saiga, Kaori; Nakae, Hisami; Kuramoto, Meiko; Makihira, Mika; Miyamoto, Yoko; Suzuki, Junji; Amano, Hideaki; Miura, Kazuo; Kawabata, Yasushi; Kozai, Katsuyuki

    2005-01-01

    The purpose of this study was to examine the longitudinal change of occlusion in children. The materials were study models obtained annually from 27 patients (17 boys and 10 girls) aged 4 to 12, having no history of significant tooth decay or orthodontic treatment. The interdental spaces in the primary dentition, the anterior occlusal relationship, the terminal plane, the relationship of the permanent first molar, and the change of occlusion from the primary dentition to the permanent dentiti...

  10. Maximizing mandibular prosthesis stability utilizing linear occlusion, occlusal plane selection, and centric recording.

    Science.gov (United States)

    Williamson, Richard A; Williamson, Anne E; Bowley, John; Toothaker, Randy

    2004-03-01

    The stability of mandibular complete dentures may be improved by reducing the transverse forces on the denture base through linear (noninterceptive) occlusion, selecting an occlusal plane that reduces horizontal vectors of force at occlusal contact, and utilizing a central bearing intraoral gothic arch tracing to record jaw relations. This article is intended to acquaint the reader with one technique for providing stable complete denture prostheses using the aforementioned materials, devices, and procedures.

  11. 〈情報学科〉均衡型(C_9, C_14)-Foil デザイン

    OpenAIRE

    潮, 和彦

    2012-01-01

    In graph theory, the decomposition problem of graphs is a very important topic. Various type of decompositions of many graphs can be seen in the literature of graph theory. This paper gives balanced (C_9, C_14)-foil designs, balanced C_23-foil designs, balanced C_46-foil designs, balanced C_69-foil designs, balanced C_92-foil designs, balanced C_115-foil designs, balanced C_138-foil designs, balanced C_161-foil designs,balanced C_184-foil designs,balanced C207-foil designs, balanced C_230-fo...

  12. Pulmonary veno-occlusive disease.

    Science.gov (United States)

    Montani, David; Lau, Edmund M; Dorfmüller, Peter; Girerd, Barbara; Jaïs, Xavier; Savale, Laurent; Perros, Frederic; Nossent, Esther; Garcia, Gilles; Parent, Florence; Fadel, Elie; Soubrier, Florent; Sitbon, Olivier; Simonneau, Gérald; Humbert, Marc

    2016-05-01

    Pulmonary veno-occlusive disease (PVOD) is a rare form of pulmonary hypertension (PH) characterised by preferential remodelling of the pulmonary venules. In the current PH classification, PVOD and pulmonary capillary haemangiomatosis (PCH) are considered to be a common entity and represent varied expressions of the same disease. The recent discovery of biallelic mutations in the EIF2AK4 gene as the cause of heritable PVOD/PCH represents a major milestone in our understanding of the molecular pathogenesis of PVOD. Although PVOD and pulmonary arterial hypertension (PAH) share a similar clinical presentation, with features of severe precapillary PH, it is important to differentiate these two conditions as PVOD carries a worse prognosis and life-threatening pulmonary oedema may occur following the initiation of PAH therapy. An accurate diagnosis of PVOD based on noninvasive investigations is possible utilising oxygen parameters, low diffusing capacity for carbon monoxide and characteristic signs on high-resolution computed tomography of the chest. No evidence-based medical therapy exists for PVOD at present and lung transplantation remains the preferred definitive therapy for eligible patients. Copyright ©ERS 2016.

  13. Thrombogenicity tests on ar-irradiated polycarbonate foils

    International Nuclear Information System (INIS)

    Trindade, Gustavo F.; Rizzutto, Marcia A.; Silva, Tiago F.; Moro, Marcos V.; Added, Nemitala; Tabacniks, Manfredo H.; Cunha, Tatiana F.; Higa, Olga Z.

    2013-01-01

    Understanding polymer surface properties is extremely important for the most wide range of their applications, from basic coating to the most complex composites and biomaterials. Low energy ion beam irradiation of polymer can improve such surface properties. By modifying its surface biocompatibility, polymers are excellent candidates for biomaterials, due to its malleability and low weight, when compared to metals. In this work, we irradiated 30-μm Bisphenol-A Polycarbonate foils with 23-keV Argon ion beam at six different doses. Aluminium foils were simultaneously irradiated in order to measure the doses by Rutherford Backscattering Spectroscopy. The surface modifications after the argon ion beam irradiation were analyzed by water contact angle measurements and atomic force microscopy. Platelet adhesion tests were used in order to investigate thrombogenicity, showing a growing tendency with the irradiated Argon dose. (author)

  14. Gas Foil Bearing Technology Advancements for Closed Brayton Cycle Turbines

    Science.gov (United States)

    Howard, Samuel A.; Bruckner, Robert J.; DellaCorte, Christopher; Radil, Kevin C.

    2007-01-01

    Closed Brayton Cycle (CBC) turbine systems are under consideration for future space electric power generation. CBC turbines convert thermal energy from a nuclear reactor, or other heat source, to electrical power using a closed-loop cycle. The operating fluid in the closed-loop is commonly a high pressure inert gas mixture that cannot tolerate contamination. One source of potential contamination in a system such as this is the lubricant used in the turbomachine bearings. Gas Foil Bearings (GFB) represent a bearing technology that eliminates the possibility of contamination by using the working fluid as the lubricant. Thus, foil bearings are well suited to application in space power CBC turbine systems. NASA Glenn Research Center is actively researching GFB technology for use in these CBC power turbines. A power loss model has been developed, and the effects of a very high ambient pressure, start-up torque, and misalignment, have been observed and are reported here.

  15. Microcutting and forming of thin aluminium foils for MEMS

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Mortensen, Dennis; Rombach, Pirmin

    2011-01-01

    This paper presents a simple procedure for simultaneous cutting and forming of thin Al foils for use in MEMS components. The procedure makes use of scaled down macroscopic sheet forming and cutting techniques by using a hydraulic press, a soft counterpart, and a microfabricated stamp tool....... The relation between applied pressure and forming and cutting features has been characterized for a specific set of stamp geometries and boundary conditions. The results show that 10 μm forming features can be transferred to 4 m thick Al foils, which simultaneously can be cut into products by 25 μm wide cut...... lines. Using the procedure presented in this paper scaled to full 4-8 in. silicon wafer stamp tools, a fast and adequate method for high volume production of MEMS components is obtained. © 2011 American Society of Mechanical Engineers....

  16. Convergent beam thickness determination of thin foil zirconium specimens

    International Nuclear Information System (INIS)

    Cann, C.D.

    1978-07-01

    The use of convergent beam patterns to determine the thickness of zirconium foils observed in the electron microscope has been investigated both theoretically and experimentally. On the basis of many-beam dynamical theory calculations, the [1012], [1013], and [1120] reflections at an accelerating voltage of 100 kV and the [1013], [1120], and [1122] reflections at 200 kV were found most suitable for convergent beam thickness determinations. Experimental convergent beam patterns were obtained in the JEOL-200B electron microscope under two different sets of conditions based on the size of the pattern desired. Computer assisted analysis of the patterns obtained gave foil thicknesses in good agreement with those determined from thickness extinction contours. (author)

  17. Tilted Foils Nuclear Spin Polarization at REX-ISOLDE

    CERN Document Server

    Törnqvist, Hans Toshihide

    2013-08-08

    This thesis will explain and summarize my work and involvement in experiments aimed at producing nuclear spin polarization of post-accelerated beams of ions with the tilted-foils technique at the REX-ISOLDE linear accelerator at CERN. Polarizing the nuclear spin of radioactive beams in particular may provide access to observables which may be difficult to obtain otherwise. Currently, the techniques commonly employed for nuclear spin polarization are restricted to specific nuclides and experimental measurement techniques. Tilted foils polarization may provide a new tool to extend the range of nuclides that can be polarized and the types of experiments that can be performed. The experiments rely not only on the production but also on the method to measure the degree of attained polarization. Two methods will be treated, based on particle scattering in Coulomb excitation that may be utilized for stable beams, and the $\\beta$-NMR that requires $\\beta$-decaying nuclei. The experimental setups and measurements will...

  18. Thrombogenicity tests on ar-irradiated polycarbonate foils

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Gustavo F.; Rizzutto, Marcia A.; Silva, Tiago F.; Moro, Marcos V.; Added, Nemitala; Tabacniks, Manfredo H., E-mail: g.ferraz@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Inst. de Fisica; Delgado, Adriana O. [Universidade Federal de Sao Carlos (UFSCAR), Sorocaba, SP (Brazil); Cunha, Tatiana F. [Biosintesis P and D do Brasil, Sao Paulo, SP (Brazil); Higa, Olga Z. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia

    2013-07-01

    Understanding polymer surface properties is extremely important for the most wide range of their applications, from basic coating to the most complex composites and biomaterials. Low energy ion beam irradiation of polymer can improve such surface properties. By modifying its surface biocompatibility, polymers are excellent candidates for biomaterials, due to its malleability and low weight, when compared to metals. In this work, we irradiated 30-μm Bisphenol-A Polycarbonate foils with 23-keV Argon ion beam at six different doses. Aluminium foils were simultaneously irradiated in order to measure the doses by Rutherford Backscattering Spectroscopy. The surface modifications after the argon ion beam irradiation were analyzed by water contact angle measurements and atomic force microscopy. Platelet adhesion tests were used in order to investigate thrombogenicity, showing a growing tendency with the irradiated Argon dose. (author)

  19. A new method for alkaline dissolution of uranium metal foil

    International Nuclear Information System (INIS)

    Mondino, A.V.; Wilkinson, M.V.; Manzini, A.C.

    2001-01-01

    In order to develop a production process of 99 Mo by fission of low-enriched uranium, the first purification step, which consists of dissolution of a uranium metal foil target, was studied. It was found that alkaline NaClO gave good results, reaching the dissolution of up to 300 μm of uranium foil. The different conditions for the dissolution were studied and the optimum ones were found. The influence of NaClO and NaOH concentration, temperature, dissolving solution volume per unit of surface and dissolution time were investigated. During this step, a gas identified as H 2 , was generated, and a precipitate characterized as Na 2 U 2 O 7 was observed. A stoichiometric reaction for this uranium dissolution is proposed. (author)

  20. Effect of phototherapy with alumunium foil reflectors on neonatal hyperbilirubinemia

    Directory of Open Access Journals (Sweden)

    Tony Ijong Dachlan

    2015-03-01

    Full Text Available Background Neonatal hyperbilirubinemia (NH is one of the most common problems in neonates, but it can be treated with blue light phototherapy. Developing countries with limited medical equipment and funds have difficulty providing effective phototherapy to treat NH, leading to increased risk of bilirubin encephalopathy. Phototherapy with white reflecting curtains can decrease the duration of phototherapy needed to reduce bilirubin levels. Objective To compare the duration of phototherapy needed in neonates with NH who underwent phototherapy with and without aluminum foil reflectors. Methods This open clinical trial was conducted from July to August 2013 at Dr. Hasan Sadikin Hospital, Bandung, Indonesia. The inclusion criteria were term neonates with uncomplicated NH presenting in their first week of life. Subjects were randomized into two groups, those who received phototherapy with or without aluminum foil reflectors. Serum bilirubin is taken at 12th, 24th, 48th hours, then every 24 hours if needed until phototherapy can be stopped according to American Academy of Pediatrics guidelines. The outcome measured was the duration of phototherapy using survival analysis. The difference between the two groups was tested by Gehan method. Results Seventy newborns who fulfilled the inclusion criteria and had similar characteristics were randomized into two groups. The duration of phototherapy needed was significantly less in the group with aluminum foil reflectors than in the group without reflectors [72 vs. 96 hours, respectively, (P<0.01]. Conclusion The required duration of phototherapy with aluminum foil reflectors is significantly less than that of phototherapy without reflectors, in neonates with NH.

  1. Note: Manganin foil sensor for small uniaxial stress

    Science.gov (United States)

    Frampton, M. K.; McLaughlin, N.; Jin, Hu; Zieve, R. J.

    2017-04-01

    We describe a simple manganin foil resistance manometer for uniaxial stress measurements. The manometer functions at low pressures and over a range of temperatures. In this design, no temperature seasoning is necessary although the manometer must be prestressed to the upper end of the desired pressure range. The prestress pressure cannot be increased arbitrarily; irreversibility arising from shear stress limits its range. Attempting larger pressures yields irreproducible resistance measurements.

  2. Dynamic nuclear polarization in thin polymer foils and tubes

    Science.gov (United States)

    van den Brandt, B.; Bunyatova, E. I.; Hautle, P.; Konter, J. A.; Mango, S.

    1995-02-01

    First results of DNP at 2.5 T and below 0.3 K in thin polymer foils and tubes with the chemical composition (CX 2) n, [ X = 1H, 2D, 19F ], doped with TEMPO, are presented. Appreciable polarization of protons, deuterons, and 19F-nuclei were obtained. The samples can be handled at room temperature for several hours, and therefore they are suitable for new applications.

  3. Dynamic nuclear polarization in thin polymer foils and tubes

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, B. van den [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Bunyatova, E.I. [Joint Inst. for Nuclear Research, Dubna (Russian Federation); Hautle, P. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Konter, J.A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Mango, S. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1995-03-01

    First results of DNP at 2.5 T and below 0.3 K in thin polymer foils and tubes with the chemical composition (CX{sub 2}){sub n}, [X={sup 1}H, {sup 2}D, {sup 19}F], doped with TEMPO, are presented. Appreciable polarizations of protons, deuterons, and {sup 19}F-nuclei were obtained. The samples can be handled at room temperature for several hours, and therefore they are suitable for new applications. ((orig.))

  4. Interaction of positron beams with thin silver foils and surfaces

    International Nuclear Information System (INIS)

    Rysholt Poulsen, M.

    1994-01-01

    Experimental investigations of positron interactions with solid silver and the necessary platform to analyse the data have been presented. The main objective was to study Ps formation at a Ag(100) surface. The different ingredients of the scenario, including thermalization and diffusion of positrons and emission of Ps, were analysed and quantified in whatever way appropriate. The scattering and possible thermalization were described. The parametrization of Monte-Carlo simulated implantation profiles for semi-infinite materials were presented and the applicability of such profiles to thin foils assessed. The latter was done in conjunction with an analysis of experimental data on thermalization and diffusion in 1900 Aa Ag(100) foils. The necessity for MC simulated rather than parametrized implantation profiles was argued. The velocity of thermally desorbed Ps from a Ag(100) surface at ∼800 K appeared to obey and one-dimensional Maxwell Boltzmann distribution multiplied by a velocity dependent factor. More experimental investigations are needed before firm conclusions can be made on the nature of the emission process. The velocity distribution, though, was found to be near-thermal and indicative of the sample temperature. It has been shown that positrons can be converted into Ps atoms in the transmission geometry of a thin 1900 Aa Ag(100) foil with a high efficiency. Furthermore, 61% of the emitted Ps will have a mean velocity of v z =1.2x10 5 m/sec and 39% will have a maximum kinetic energy of 1.5 eV (v z =5.1x10 5 m/sec) at a foil temperature of 800 K, all velocities that are suitable for producing a 'dense' Ps gas target. (EG) 12 refs

  5. Synthetic Graphene Grown by Chemical Vapor Deposition on Copper Foils

    Science.gov (United States)

    2013-04-11

    review the synthesis and properties of CVD -grown graphene , demonstrated using examples pimarily from our work in re- cent years. Particularly, we will...promise for many applica- tions.60 Compared to other large-scale graphene synthesis methods, CVD -grown graphene on copper foil substrates has been shown to...methods. Despite the fact that CVD - grown graphene films may be less perfect (the presence of domain boundaries, defects, wrinkles, impurities and

  6. A Manganin Foil Sensor for Small Uniaxial Stress

    OpenAIRE

    Frampton, M. K.; McLaughlin, N.; Jin, Hu; Zieve, R. J.

    2017-01-01

    We describe a simple manganin foil resistance manometer for uniaxial stress measurements. The manometer functions at low pressures and over a range of temperatures. In this design no temperature seasoning is necessary, although the manometer must be prestressed to the upper end of the desired pressure range. The prestress pressure cannot be increased arbitrarily; irreversibility arising from shear stress limits its range. Attempting larger pressures yields irreproducible resistance measurements.

  7. Ablative acceleration of thin foil targets by intense proton beams

    International Nuclear Information System (INIS)

    Miyamoto, S.; Ozaki, T.; Imasaki, K.; Higaki, S.; Nakai, S.

    1981-01-01

    A focused proton beam of up to 2 x 10 10 w/cm 2 was obtained using pinch-reflex ion diode connected to Reiden IV generator. Experiments of beam target interaction have been done using thin foil targets. In this power range the interaction was explained classically. The experimental dependence of ablation pressure on proton beam intensity was obtained as P sub(a) = 3 x 10 -3 I sup(0.7) bar (I in w/cm 2 ). (author)

  8. Percutaneous sharp recanalization of a membranous IVC occlusion with an occlusion balloon as a needle target

    Directory of Open Access Journals (Sweden)

    Michael D. Rivers-Bowerman, MD, MSc, FRCPC

    2017-09-01

    Full Text Available A 50-year-old male with right upper quadrant symptoms and hepatic dysfunction was found to have multiple dilated hepatic veins (HVs with intrahepatic collateralization and membranous occlusion of the intrahepatic inferior vena cava (IVC consistent with primary Budd–Chiari syndrome. Venacavograms depicted drainage of the intrahepatic collaterals through a left-sided HV entering the IVC above the level of the occlusion. Sharp recanalization of the membranous IVC occlusion was performed with an occlusion balloon as a needle target under echocardiographic monitoring followed by balloon angioplasty with restoration of IVC patency. Clinical, laboratory, and venographic procedural success has been demonstrated to 9 months with minimal residual stenosis.

  9. Branch retinal artery occlusion in Susac's syndrome

    Directory of Open Access Journals (Sweden)

    Ricardo Evangelista Marrocos de Aragão

    2015-02-01

    Full Text Available Susac's syndrome is a rare disease attribuited to a microangiopathy involving the arterioles of the cochlea, retina and brain. Encefalopathy, hearing loss, and visual deficits are the hallmarks of the disease. Visual loss is due to multiple, recurrent branch arterial retinal occlusions. We report a case of a 20-year-old women with Susac syndrome presented with peripheral vestibular syndrome, hearing loss, ataxia, vertigo, and vision loss due occlusion of the retinal branch artery.

  10. Occlusion Issues in Early Renaissance Art

    OpenAIRE

    Barbara Gillam

    2011-01-01

    Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surfac...

  11. Current possibilities in occlusal caries management

    Directory of Open Access Journals (Sweden)

    Hrvoje Jurić

    2013-11-01

    Full Text Available Dental caries is a multifactorial disease that affects most populations throughout the world and it is still the primary cause of oral pain and tooth loss. The occlusal surfaces of posterior teeth are the most vulnerable sites for dental caries due to their anatomy. Therefore, the aim of the following article is to summarize current knowledge on occlusal caries development and the possibilities of its prevention. Although the overall caries rate today has fallen for populations in industrialized countries, the rate of occlusal surface caries has not decreased. This may be explained with fact that topically applied fluorides and their mode of action prevent caries better on smooth than on occlusal surfaces. As we know, tooth decay of first permanent molars causes a great deal of different short and long term difficulties for patients. Therefore, there is a continuous need for implementation of programs for caries prevention in permanent teeth. Nowadays, we like to treat our patients by minimally invasive methods. A very important step in our effective preventive treatment is sealing pits and fissures as a cornerstone of occlusal caries management. Reliable assessment of caries activity is also very important for defining treatment needs and plans. A very important decision, which should be made during occlusal caries management, is the selection of restorative material according to the treatment plan. Conclusion. Current possibilities in occlusal caries prevention and management are very effective. Therefore, dentists today do not have any excuse for avoiding the philosophy of Minimally Invasive Dentistry, especially when we talk about caries management of occlusal surfaces in permanent molars.

  12. Flapping propulsion with side-by-side pitching foils

    Science.gov (United States)

    Huera-Huarte, Francisco

    2016-11-01

    Fish schools are one of the most common types of collective behaviour observed in nature. One of the reasons why fish swim in groups, is to reduce the cost of transport of the school. In this work we explore the propulsive performance of two foils flapping in a symmetric configuration, i.e. with an out-of-phase flapping motion. Direct thrust measurements and Particle Image Velocimetry (PIV) allowed a detailed examination of the forces and the wake generated by the system, for different kinematics (swept angles and frequencies) and shaft separations. For certain specific cases, volumetric PIV shows major differences on how the different structures in the wake of the system evolve, depending on the imposed kinematics and the side-by-side separation between the foils. Results obtained will be compared against data produced with isolated flapping foils with similar imposed kinematics, with the aim to better understand the interactions between both and the performance of the system as a whole. The author would like to acknowledge the financial support provided by the Spanish Ministerio de Economia y competitividad (MINECO) through Grant DPI2015-71645-P.

  13. Design of organic complementary circuits and systems on foil

    CERN Document Server

    Abdinia, Sahel; Cantatore, Eugenio

    2015-01-01

    This book describes new approaches to fabricate complementary organic electronics, and focuses on the design of circuits and practical systems created using these manufacturing approaches. The authors describe two state-of-the-art, complementary organic technologies, characteristics and modeling of their transistors and their capability to implement circuits and systems on foil. Readers will benefit from the valuable overview of the challenges and opportunities that these extremely innovative technologies provide. ·         Demonstrates first circuits implemented using specific complementary organic technologies, including first printed analog to digital converter, first dynamic logic on foil and largest complementary organic circuit ·         Includes step-by-step design from single transistor level to complete systems on foil ·         Provides a platform for comparing state-of-the-art complementary organic technologies and for comparing these with other similar technologies, spec...

  14. Element segregation on the surfaces of pure aluminum foils

    International Nuclear Information System (INIS)

    Zhang Xinming; Liu Jiancai; Tang Jianguo; Li Li; Chen Mingan; Liu Shengdan; Zhu Bing

    2010-01-01

    The surface segregation trend of trace elements in pure aluminum foils was investigated by density functional theory. The model of nine-layer Al(1 0 0) slab substituted partially by trace element atoms was proposed for calculating surface segregation energy. The calculating results show that (i) B, Mg, Si, Ga, Ge, Y, In, Sn, Sb, Pb and Bi exhibit negative segregation energy and possibly move to the surface, while Be, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zr exhibit positive segregation energies and migrated into the bulk; (ii) the segregation energy was found to be related with the covalent radius, the relaxed position at the surface of the substituting atom and the surface energy; (iii) the segregation behavior of trace element generates lots of defects and dislocation, which can increase the initial pitting nucleation sites in the surface of aluminum foils; (iv) the impurity atom concentration was tested with Pb-doped surfaces, the calculated negative segregation energies in all coverage increases rapidly with the Pb coverage. These conclusions are helpful for designing of the chemical composition and to advance the tunnel etching of aluminum foils.

  15. Small incision removal of nylon foil orbital implants.

    Science.gov (United States)

    Liu, Catherine Y; Vemuri, Swapna; Tao, Jeremiah P

    2015-01-01

    To describe a small incision technique for the removal of a nylon foil orbital wall implant. The authors retrospectively reviewed the charts of 9 patients who underwent a minimally invasive anterior orbitotomy for nylon foil explantation. Indications for removal and surgical technique, including size of orbitotomy incision and extent of orbital dissection, were recorded. Motility, globe position, strabismus pre- and post procedure, and complications were also assessed. Photographs, videos, and postoperative imaging were included, when available. The indications for removal were adjacent sinusitis (4 cases), undesirable implant position (3), orbital abscess (1), and adjacent orbital emphysema (1). The removal technique was associated with no changes in motility, globe position, or strabismus postprocedure. The average incision size was 1.1 cm, and the procedure was rapid, usually seconds once the anterior aspect of the implant was exposed and grasped with a hemostat. The dissection in all cases was to the anterior aspect of the implant without a need for deep orbital manipulation. The authors demonstrate through video that the implant folds to exit through a small incision. No adverse events were noted. Nasal endoscopy and radiography demonstrated a fibrous capsule that maintained orbital structure and support. Thin nylon foil implant can be explanted safely and efficiently through a very small incision. The orbit maintains structure and configuration postexplantation in this series.

  16. Simulation of thin aluminium-foil in the packaging industry

    Science.gov (United States)

    Eskil, Andreasson; Lindström, Tommy; Käck, Britta; Malmberg, Christoffer; Asp, Ann-Magret

    2017-10-01

    This work present an approach of how to account for the anisotropic mechanical material behaviour in the simulation models of the thin aluminium foil layer (≈10 µm) used in the Packaging Industry. Furthermore, the experimental results from uniaxial tensile tests are parameterised into an analytical expression and the slope of the hardening subsequently extended way beyond the experimental data points. This in order to accommodate the locally high stresses present in the experiments at the neck formation. An analytical expression, denominated Ramberg-Osgood, is used to describe the non-linear mechanical behaviour. Moreover it is possible with a direct method to translate the experimental uniaxial tensile test results into useful numerical material model parameters in Abaqus™. In addition to this the extended material behaviour including the plastic flow i.e. hardening, valid after onset of localisation, the described procedure can also capture the microscopic events, i.e. geometrical thinning, ongoing in the deformation of the aluminium foil. This method has earlier successfully been applied by Petri Mäkelä for paperboard material [1]. The engineering sound and parameterised description of the mechanical material behaviour facilitates an efficient categorisation of different aluminium foil alloys and aid the identification of the correct anisotropic (RD/TD/45°) mechanical material behaviour derived from the physical testing.

  17. Propulsive performance of pitching foils with variable chordwise flexibility

    Science.gov (United States)

    Zeyghami, Samane; Moored, Keith; Lehigh University Team

    2017-11-01

    Many swimming and flying animals propel themselves efficiently through water by oscillating flexible fins. These fins are not homogeneously flexible, but instead their flexural stiffness varies along their chord and span. Here we seek to evaluate the effect stiffness profile on the propulsive performance of pitching foils. Stiffness profile characterizes the variation in the local fin stiffness along the chord. To this aim, we developed a low order model of a functionally-graded material where the chordwise flexibility is modeled by two torsional springs along the chordline and the stiffness and location of the springs can be varied arbitrarily. The torsional spring structural model is then strongly coupled to a boundary element fluid model to simulate the fluid-structure interactions. Keeping the leading edge kinematics unchanged, we alter the stiffness profile of the foil and allow it to swim freely in response to the resulting hydrodynamic forces. We then detail the dependency of the hydrodynamic performance and the wake structure to the variations in the local structural properties of the foil.

  18. Effect of occlusal plane on smile attractiveness.

    Science.gov (United States)

    Batwa, Waeil; Hunt, Nigel P; Petrie, Aviva; Gill, Daljit

    2012-03-01

    To determine the influence of the occlusal plane angle on smile attractiveness as perceived by a group of adult orthodontic patients and dentists. The first stage utilized a laboratory approach to record changes in vertical tooth position at different occlusal plane angles using a maxillary model mounted on an articulator. In the second stage, photographic manipulation was undertaken, using data from stage 1, to produce a computerized prediction of the appearance of the smile at differing occlusal plane angles (0, 5, 10, 15, and 20 degrees). Finally, the five developed photographs were assessed by participants. Alterations in the occlusal plane angle did affect relative smile attractiveness for both patients (n  =  66) and dentists (n  =  66). For patients, the 10 degree smile was rated better than the 0 and 20 degree smiles (P occlusal plane angle does affect relative smile attractiveness. However, patients were more tolerant of these changes than dentists. This suggests that large changes in the occlusal plane angle would affect relative smile attractiveness, and small changes are unlikely to affect smile attractiveness.

  19. The effects of passive foil flexibility on the energy extraction performance of an oscillating foil operating at low reduced frequencies

    Science.gov (United States)

    Totpal, Alexander D.; Siala, Firas F.; Liburdy, James A.

    2016-11-01

    With a goal to improve energy extraction efficiency from an oscillating foil, direct aerodynamic force measurements are used to study the effect of surface flexibility of an oscillating foil operating in the energy harvesting regime. The experiments are conducted in a closed-loop wind tunnel at a low reduced frequencies range of 0.04-0.06. The pitching amplitude was varied from 45 to 90 degrees and the phase shift between pitching and heaving motions was varied from 30 to 120 degrees. Three different airfoil configurations were tested: fully rigid, flexible leading edge and flexible trailing edge. In addition, phase-locked particle image velocimetry (PIV) measurements were taken at the higher efficiency cases, and are used to help interpret trends seen in the force measurement data. The timing and position of the leading edge vortex along the foil, which has been shown to be crucial to energy extraction, is investigated in order to help explain why certain operating conditions yield larger efficiencies.

  20. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  1. Pure commercial gold foils as neutron flux monitor: Neutron self-shielding assessment

    International Nuclear Information System (INIS)

    Haddad, Kh.; Haj-Hassan, H.; Helal, W.

    2007-01-01

    An assessment of pure commercial (99.9%) gold foils as neutron flux monitor was performed. A thin foils of pure commercial gold were prepared as an in-house reference material for neutron flux measurement. The assessed foils are available commercially and its cost is much less than the certified ones. Determination of the neutron self-shielding factors in these foils for both thermal and epithermal neutrons have been done experimentally. These foils show good results repeatability and good agreement with certified activation monitors. According to the well-known physical constants of the nuclide and its low cost comparing with certified foils, it can be used as an in-house reference monitor

  2. Development of Gating Foils To Inhibit Ion Feedback Using FPC Production Techniques

    Science.gov (United States)

    Arai, D.; Ikematsu, K.; Sugiyama, A.; Iwamura, M.; Koto, A.; Katsuki, K.; Fujii, K.; Matsuda, T.

    2018-02-01

    Positive ion feedback from a gas amplification device to the drift region of the Time Projection Chamber for the ILC can deteriorate the position resolution. In order to inhibit the feedback ions, MPGD-based gating foils having good electron transmission have been developed to be used instead of the conventional wire gate. The gating foil needs to control the electric field locally in opening or closing the gate. The gating foil with a GEM (gas electron multiplier)-like structure has larger holes and smaller thickness than standard GEMs for gas amplification. It is known that the foil transmits over 80 % of electrons and blocks ions almost completely. We have developed the gating foils using flexible printed circuit (FPC) production techniques including an improved single-mask process. In this paper, we report on the production technique of 335 μm pitch, 12.5 μm thick gating foil with 80 % transmittance of electrons in ILC conditions.

  3. Control of Oscillating Foil for Propulsion of Biorobotic Autonomous Underwater Vehicle (AUV

    Directory of Open Access Journals (Sweden)

    S. N. Singh

    2005-01-01

    Full Text Available The paper treats the question of control of a laterally and rotationally oscillating hydrofoil for the propulsion of biologically inspired robotic (biorobotic autonomous underwater vehicles (BAUVs. Sinusoidal oscillations of foils produce maneuvering and propulsive forces. The design is based on the internal model principle. Two springs are used to transmit forces from the actuators to the foil. Oscillating fins produce periodic forces, which can be used for fish-like propulsion and control of autonomous underwater vehicles (AUVs. The equations of motion of the foil include hydrodynamic lift and moment based on linear, unsteady, aerodynamic theory. A control law is derived for the lateral and rotational sinusoidal oscillation of the foil. In the closed-loop system, the lateral displacement and the rotational angle of the foil asymptotically follow sinusoidal trajectories of distinct frequencies and amplitudes independently. Simulation results are presented to show the trajectory tracking performance of the foil for different freestream velocities and sinusoidal command trajectories.

  4. The stripping foil test stand in the Linac4 transfer line

    CERN Document Server

    Weterings, W; Noulibos, R; Sillanoli, Y; van Trappen, P

    2015-01-01

    The 160 MeV H− beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H− charge-exchange injection system. It will include a stripping foil, to convert H− into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters.

  5. The stripping foil test stand in the Linac4 transfer line

    International Nuclear Information System (INIS)

    Weterings, W.; Bracco, C.; Noulibos, R.; Sillanoli, Y.; Trappen van, P.

    2015-01-01

    The 160 MeV H - beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H - charge-exchange injection system. It will include a stripping foil, to convert H - into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters. (author)

  6. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  7. Occlusion issues in early Renaissance art

    Science.gov (United States)

    Gillam, Barbara

    2011-01-01

    Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surface overlap is often achieved by implementing the principle that an occluding surface occludes anything behind it, so that occlusion perception is enhanced by a lack of relationship of occluding contour to occluded contours. Some well-known figure-ground principles are also commonly used to stratify adjoined figures. Global factors that assist this stratification include the placement of figures on a ground plane, a high viewpoint, and figure grouping. Artists of this period seem to have differed on whether to occlude faces and heads, often carefully avoiding doing so. Halos were either eliminated selectively or placed oddly to avoid such occlusions. Finally, I argue that the marked intransitivity in occlusion by architecture in the paintings of Duccio can be related to the issue of perceptual versus cognitive influences on the visual impact of paintings. PMID:23145262

  8. Depicting Occlusion in Early Renaissance Art

    Science.gov (United States)

    Gillam, Barbara

    2011-01-01

    The artist attempting to give the impression of three-dimensional relationships must convey somehow that one surface is in front of another. There is a large and venerable literature in Psychology on this subject, showing how figure-ground, border ownership and amodal completion and continuation are determined but there is almost no discussion of how artist's have recruited these and other principles to create convincing impressions of occlusion. Even Gombrich (Art & Illusion 1960) only considers the situation in which a figure has to be imagined from very partial cues, not how juxtaposed elements in art are parsed perceptually into occluding and occluded surfaces. In this paper I shall discuss approaches to occlusion present in early Renaissance art and the degree to which the principles now well-known to Psychologists were discovered and used, as artists increasingly depicted naturalistic scenes. Among the preoccupations of these artists, as indicated by their work, were whether and how much to occlude faces (and the related issue of the management of haloes), occlusion of and by architectural features, and the importance or otherwise of transitivity in occlusion relationships within the scene. They also clearly used the ground plane, high viewpoints and arrangements of contour terminations, as well as more conventional figural cues, to disambiguate perceived occlusion or to avoid the confusion of multiple surfaces.

  9. Depicting Occlusion in Early Renaissance Art

    Directory of Open Access Journals (Sweden)

    Barbara Gillam

    2011-05-01

    Full Text Available The artist attempting to give the impression of three-dimensional relationships must convey somehow that one surface is in front of another. There is a large and venerable literature in Psychology on this subject, showing how figure-ground, border ownership and amodal completion and continuation are determined but there is almost no discussion of how artist's have recruited these and other principles to create convincing impressions of occlusion. Even Gombrich (Art & Illusion 1960 only considers the situation in which a figure has to be imagined from very partial cues, not how juxtaposed elements in art are parsed perceptually into occluding and occluded surfaces. In this paper I shall discuss approaches to occlusion present in early Renaissance art and the degree to which the principles now well-known to Psychologists were discovered and used, as artists increasingly depicted naturalistic scenes. Among the preoccupations of these artists, as indicated by their work, were whether and how much to occlude faces (and the related issue of the management of haloes, occlusion of and by architectural features, and the importance or otherwise of transitivity in occlusion relationships within the scene. They also clearly used the ground plane, high viewpoints and arrangements of contour terminations, as well as more conventional figural cues, to disambiguate perceived occlusion or to avoid the confusion of multiple surfaces.

  10. Occlusion Issues in Early Renaissance Art

    Directory of Open Access Journals (Sweden)

    Barbara Gillam

    2011-12-01

    Full Text Available Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surface overlap is often achieved by implementing the principle that an occluding surface occludes anything behind it, so that occlusion perception is enhanced by a lack of relationship of occluding contour to occluded contours. Some well-known figure-ground principles are also commonly used to stratify adjoined figures. Global factors that assist this stratification include the placement of figures on a ground plane, a high viewpoint, and figure grouping. Artists of this period seem to have differed on whether to occlude faces and heads, often carefully avoiding doing so. Halos were either eliminated selectively or placed oddly to avoid such occlusions. Finally, I argue that the marked intransitivity in occlusion by architecture in the paintings of Duccio can be related to the issue of perceptual versus cognitive influences on the visual impact of paintings.

  11. Temporomandibular Disorders Treatment with Correction of Decreased Occlusal Vertical Dimension.

    Science.gov (United States)

    Guguvcevski, Ljuben; Gigovski, Nikola; Mijoska, Aneta; Zlatanovska, Katerina; Arsova-Gigovska, Ana

    2017-12-15

    The term decreased occlusal vertical dimension refers to the reduced distance between two anatomical points while the teeth are in a state of occlusion. The development of this situation is about some parafunctional activities of the masticatory system. To evaluate the value of decreased occlusal vertical dimension in cases with temporomandibular disorder and to follow up the influence of corrective treatment with occlusal splints and definitive prosthetic construction upon the elimination of clinical symptoms. Eight cases with decreased occlusal vertical dimension accompanied with temporomandibular disorders were treated with an occlusal splint, as part of reversible occlusal treatment. After reducing, or complete elimination of the symptoms related to problems of decreased occlusal vertical dimension, the definitive prosthetic therapy was performed. The mean value of decreased occlusal vertical dimension in our patients is 8.5 mm, and the mean value of therapy time with an occlusal splint in these patients was 3.5 months. Occlusal splint is a part of reversible occlusal therapy in cases with decreased occlusal vertical dimension. After reducing the symptoms related to decreased occlusal vertical dimension definitive prosthetic therapy can be done.

  12. Transmission of Fast Highly Charged Ions through a Single Glass Macrocapillary and Polycarbonate Nanocapillary Foils

    Science.gov (United States)

    Ayyad, A. M.; Dassanayake, B. S.; Keerthisinghe, D.; DeSilva, G. G.; Elkafrawy, T.; Kayani, N.; Tanis, J. A.

    2012-11-01

    Transmission of 3 MeV protons and 16 MeV O5+ ions through a single glass macrocapillary and a polycarbonate nanocapillary foil has been investigated. Results show that 3 MeV protons transmit through the capillary and the foils with little or no energy loss, while 16 MeV O5+ ions show transmission through the capillary and the foil with energy losses that vary with the tilt angle, and there are also changes in the charge state.

  13. X-Ray Measurements Of Total Reflectivity And Scattering From Au-Coated Foils

    DEFF Research Database (Denmark)

    Hornstrup, Allan; Christensen, Finn Erland; Schnopper, H. W.

    1989-01-01

    We present X-ray measurements of total reflectivity and scattering from gold coated foils. The foils are two sorts of 0.3 mm thick dip-lacquered aluminum, 0.125 mm thick plastic (Upilex) and 0.5 mm thick dip-lacquered nickel. The analysis of the data show a high reflectivity for all but the plastic...... foil, and only small microroughness (-10A at lengthscales below -0.1 micron), evidenced by low resolution scat-tering measurements....

  14. Beam-foil-gas spectroscopy - A technique for studying steady-state non-equilibrium processes.

    Science.gov (United States)

    Bickel, W. S.; Veje, E.; Carriveau, G.; Anderson, N.

    1971-01-01

    When a thin foil is inserted in the beam of a beam-gas experiment, the beam particle state populations are driven far from their beam-gas equilibrium values. Downstream from the foil, the 'new beam' and gas species interact to produce a new equilibrium, usually different from the beam-gas equilibrium. Experimental results are presented to demonstrate this effect and to show how relative cross-section measurements can be used to study the beam-foil interaction.

  15. Stripping Foil Issues for H- Injection into the CERN PSB at 160 MeV

    CERN Document Server

    Goddard, B; Bracco, C; Carli, C; Meddahi, M; Weterings, W J M

    2010-01-01

    Beam physics considerations for the stripping foil of the 160 MeV PSB H- injection systems are described, including the arguments for the foil type, thickness, geometry and positioning. The foil performance considerations are described, including expected stripping efficiency, emittance growth, energy straggling, temperature and lifetime. The different beam loss mechanisms are quantified in the context of the aperture limits, operational considerations and collimation requirements.

  16. Experimental and theoretical analysis of a rigid rotor supported by air foil bearings

    DEFF Research Database (Denmark)

    Larsen, Jon Steffen; Hansen, Asger J. T.; Santos, Ilmar

    2015-01-01

    The popularity of compressors utilizing foil bearings is increasing. Their mechanical design is challenging, and an accurate prediction of the bearing coefficients is important. A mathematical model taking into account the foil structure, and the detailed geometry of a three pad foil bearing are ...... for the first order equation. Calculated bearing coefficients are compared to experimental results obtained from a dedicated test rig. Generally, good agreement is observed and minor discrepancies for the damping coefficients are discussed....

  17. Prevalence and association of headaches, temporomandibular joint disorders, and occlusal interferences.

    Science.gov (United States)

    Troeltzsch, M; Troeltzsch, M; Cronin, R J; Brodine, A H; Frankenberger, R; Messlinger, K

    2011-06-01

    Although an interaction of malocclusion, parafunction, and temporomandibular joint disorders (TMD) can be inferred from the experience of daily practice, scientific evidence to corroborate this hypothesis does not exist. However, there are indications that TMD and headaches may be intertwined. The purpose of this study was to identify the presence or absence of an association of occlusal interferences, parafunction, TMD, or physiologic, muscular, or prosthodontic factors with the occurrence of headache. In a private practice population of 1031 subjects (436 men and 595 women, mean age 49.6 years) the demographic parameters, headache and general pain history, habits and general personal information were recorded. Clinical examination for dental, muscular, and temporomandibular joint pathology was accomplished. Data were statistically analyzed using the Mann-Whitney U, Kruskal-Wallis, and Chi-Square tests (α = .05). A multinomial logistic regression analysis was performed with respect to confounding variables. Headache affliction was found to affect women more frequently than men (1.7:1). Students and non academics were more prone to suffer from headache. Parafunction (P=.001), TMD (P=.001) and gross differences between centric occlusion and maximum intercuspation of more than a 3 mm visible track marked with 8 μm articulation foil (P=.001) significantly influenced the presence of headache. Headache intensity and frequency decreased with age. While tension-type headache was most frequently diagnosed, the parameters studied were not significantly associated with one certain headache diagnosis more frequently than others. Stomatognathic factors of TMD, parafunction, and gross differences between centric occlusion and maximum intercuspation of more than 3 mm are associated with headache. These findings should be interpreted with caution due to the cross-sectional nature of this study. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry

  18. Analysis of Cartilage-Polydioxanone Foil Composite Grafts

    Science.gov (United States)

    Kim, James H.; Wong, Brian

    2014-01-01

    This study presents an analytical investigation into the mechanical behavior of a cartilage-polydioxanone (PDS) plate composite grafts. Numerical methods are used to provide a first-order, numerical model of the flexural stiffness of a cartilage-PDS graft. Flexural stiffness is a measure of resistance to bending and is inversely related to the amount of deformation a structure may experience when subjected to bending forces. The cartilage-PDS graft was modeled as a single composite beam. Using Bernoulli-Euler beam theory, a closed form equation for the theoretical flexural stiffness of the composite graft was developed. A parametric analysis was performed to see how the flexural properties of the composite model changed with varying thicknesses of PDS foil. The stiffness of the cartilage-PDS composite using 0.15-mm-thick PDS was four times higher than cartilage alone. The composite with a 0.5-mm-thick PDS graft was only 1.7 times stiffer than the composite with the 0.15-mm-thick PDS graft. Although a thicker graft material will yield higher flexural stiffness for the composite, the relationship between composite stiffness and PDS thickness is nonlinear. After a critical point, increments in graft thickness produce gradually smaller improvements in flexural stiffness. The small increase in stiffness when using the thicker PDS foils versus the 0.15 mm PDS foil may not be worth the potential complications (prolonged foreign body reaction, reduction in nutrient diffusion to cartilage) of using thicker artificial grafts. PMID:24327249

  19. Large-area monolayer hexagonal boron nitride on Pt foil.

    Science.gov (United States)

    Park, Ji-Hoon; Park, Jin Cheol; Yun, Seok Joon; Kim, Hyun; Luong, Dinh Hoa; Kim, Soo Min; Choi, Soo Ho; Yang, Woochul; Kong, Jing; Kim, Ki Kang; Lee, Young Hee

    2014-08-26

    Hexagonal boron nitride (h-BN) has recently been in the spotlight due to its numerous applications including its being an ideal substrate for two-dimensional electronics, a tunneling material for vertical tunneling devices, and a growth template for heterostructures. However, to obtain a large area of h-BN film while maintaining uniform thickness is still challenging and has not been realized. Here, we report the systematical study of h-BN growth on Pt foil by using low pressure chemical vapor deposition with a borazine source. The monolayer h-BN film was obtained over the whole Pt foil (2 × 5 cm(2)) under foil size. A borazine source was catalytically decomposed on the Pt surface, leading to the self-limiting growth of the monolayer without the associating precipitation, which is very similar to the growth of graphene on Cu. The orientation of the h-BN domains was largely confined by the Pt domain, which is confirmed by polarizing optical microscopy (POM) assisted by the nematic liquid crystal (LC) film. The total pressure and orientation of the Pt lattice plane are crucial parameters for thickness control. At high pressure (∼0.5 Torr), thick film was grown on Pt (111), and in contrast, thin film was grown on Pt (001). Our advances in monolayer h-BN growth will play an important role to further develop a high quality h-BN film that can be used for vertical tunneling, optoelectronic devices and growth templates for a variety of heterostructures.

  20. Corrections in the gold foil activation method for determination of neutron beam density

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage

    1967-01-01

    A finite foil thickness and deviation in the cross section from the 1ν law imply corrections in the determination of neutron beam densities by means of foil activation. These corrections, which depend on the neutron velocity distribution, have been examined in general and are given in a specific...... example for a reactor beam transmitted through a 30 cm Bi filter. The effective cross section differs 0.5% from the capture cross section at 2200 m/s. For a 20 mg/cm2 Au foil the correction for beam attenuation and hardening through the foil is 0.7% and the activity correction is 1.5%....

  1. Development progress of wide LEU foils for Mo-99 irradiation target at KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Hwan; Son, Myung Koon; Lee, Don Bae; Lee, Byung Chul; Kim, Chang Kyu [Korea Atomic Energy Research Institute , Taejon (Korea, Republic of)

    2005-07-01

    As the uranium foils for Mo-99 irradiation target, which are charged into a reactor, can be conventionally fabricated at laboratory scale, but not yet at a commercialized scale by a hot rolling method due to some problems in foil quality, productivity and economic efficiency, an attention has shifted to the development of new improved technology. Under these circumstances, an alternative fabrication method of U polycrystalline foils has been investigated using a cooling roll casting method, in order to produce a fission isotope {sup 99}Mo, the parent nuclide of {sup 99m}Tc. The fabrication method of wide LEU foils produced by a coolingroll casting was recently developed to improve the quality of the uranium foils and the economic efficiency of the foil fabrication with modifications of the casting apparatus and adjustments of the process parameters. A continuous polycrystalline LEU foil with a thickness range of 100 to 150{mu}m and a width of about 50 mm, exceeding 5m in length for a batch procedure, could be fabricated with a better quality of the uranium foil and a higher yield of the foil fabrication, through improvements of the casting apparatus and variations of the process parameters.

  2. Development progress of wide LEU foils for Mo-99 irradiation target at KAERI

    International Nuclear Information System (INIS)

    Kim, Ki Hwan; Son, Myung Koon; Lee, Don Bae; Lee, Byung Chul; Kim, Chang Kyu

    2005-01-01

    As the uranium foils for Mo-99 irradiation target, which are charged into a reactor, can be conventionally fabricated at laboratory scale, but not yet at a commercialized scale by a hot rolling method due to some problems in foil quality, productivity and economic efficiency, an attention has shifted to the development of new improved technology. Under these circumstances, an alternative fabrication method of U polycrystalline foils has been investigated using a cooling roll casting method, in order to produce a fission isotope 99 Mo, the parent nuclide of 99m Tc. The fabrication method of wide LEU foils produced by a coolingroll casting was recently developed to improve the quality of the uranium foils and the economic efficiency of the foil fabrication with modifications of the casting apparatus and adjustments of the process parameters. A continuous polycrystalline LEU foil with a thickness range of 100 to 150μm and a width of about 50 mm, exceeding 5m in length for a batch procedure, could be fabricated with a better quality of the uranium foil and a higher yield of the foil fabrication, through improvements of the casting apparatus and variations of the process parameters

  3. Foil system fatigue load environments for commercial hydrofoil operation

    Science.gov (United States)

    Graves, D. L.

    1979-01-01

    The hydrofoil fatigue loads environment in the open sea is examined. The random nature of wave orbital velocities, periods and heights plus boat heading, speed and control system design are considered in the assessment of structural fatigue requirements. Major nonlinear load events such as hull slamming and foil unwetting are included in the fatigue environment. Full scale rough water load tests, field experience plus analytical loads work on the model 929 Jetfoil commercial hydrofoil are discussed. The problem of developing an overall sea environment for design is defined. State of the art analytical approaches are examined.

  4. Critical mass experiment using U-235 foils and lucite plates

    International Nuclear Information System (INIS)

    Sanchez, R.; Butterfield, K.; Kimpland, R.; Jaegers, P.

    1998-01-01

    The main objective of this experiment was to show how the multiplication of the system increases as moderated material is placed between highly enriched uranium foils. In addition, this experiment served to demonstrate the hand-stacking techniques, and approach to criticality by remote operation. This experiment was designed by Tom McLaughlin in the mid seventies as part of the criticality safety course that is taught at Los Alamos Critical Experiment Facility (LACEF). The W-U-235 ratio for this experiment was 215 which is where the minimum critical mass for this configuration occurs

  5. Optical observations of molecular dissociation in thin foils

    International Nuclear Information System (INIS)

    Berry, H.G.; Gay, T.J.; Brooks, R.L.

    1981-01-01

    We have measured the intensity and polarizations of light emitted from atomic excited states of dissociated molecular ions. Using HeH + projectiles, we have observed factors of 1-5 enhancements of the light from n=3, sup(1,3)P,D states of He I and some He II and H I emissions. Observations of Lyman alpha emission after dissociation of H 2 + and H 3 + show rapid variations in light yield for small internuclear separations at the foil surface. (author)

  6. Prediction of Gas Lubricated Foil Journal Bearing Performance

    Science.gov (United States)

    Carpino, Marc; Talmage, Gita

    2003-01-01

    This report summarizes the progress in the first eight months of the project. The objectives of this research project are to theoretically predict the steady operating conditions and the rotor dynamic coefficients of gas foil journal bearings. The project is currently on or ahead of schedule with the development of a finite element code that predicts steady bearing performance characteristics such as film thickness, pressure, load, and drag. Graphical results for a typical bearing are presented in the report. Project plans for the next year are discussed.

  7. Measurement of neutron multiplication in Pb by Mn foils

    International Nuclear Information System (INIS)

    Chen Yuan; Liu Rong; Guo Haiping; Jiang Wenmian; Shen Jian

    1994-01-01

    The Leakage neutron multiplication in bulk lead has been measured using the total absorption detector and relative method. The polyethylene sphere of 138 cm in diameter is used as the moderator and total absorption detector. The measured results from 55 Mn foils and 6 Li glass are compared. The neutron multiplication is 1.74 with the lead shell of 23.1 cm thick. The measured result is consistent with the calculated one with ANISN code and ENDF/B-6 evaluated data within the experimental error. (4 figs., 3 tabs.)

  8. Occlusal Caries: Biological Approach for Its Diagnosis and Management

    DEFF Research Database (Denmark)

    Christina Carvalho, Joana; Dige, Irene; Machiulskiene, Vita

    2016-01-01

    The management of occlusal caries still remains a major challenge for researchers as well as for general practitioners. The present paper reviews and discusses the most up-to-date knowledge and evidence of the biological principles guiding diagnosis, risk assessment, and management of the caries...... process on occlusal surfaces. In addition, it considers the whole spectrum of the caries process on occlusal surfaces, ranging from the molecular ecology of occlusal biofilms to the management of deep occlusal caries lesions. Studies using molecular methods with focus on biofilms in relation to occlusal...

  9. Effect of glove occlusion on the skin barrier

    DEFF Research Database (Denmark)

    Tiedemann, Daniel; Clausen, Maja Lisa; John, Swen Malthe

    2016-01-01

    that the negative effect of occlusion in itself is limited, and that only extensive and long-term occlusion will cause barrier impairment. However, studies investigating combined effect of occlusion and exposure to soaps/detergents indicate that occlusion significantly enhances the skin barrier damage caused...... of this study is to review the literature on the effects of glove occlusion on skin barrier function. The PubMed database was searched up to 1 February 2015 for articles on the association between glove occlusion and skin barrier function, including human studies only and in English. Only experimental studies...... by detergents/soaps in a dose-response fashion....

  10. Compliance with occlusion therapy for childhood amblyopia.

    Science.gov (United States)

    Wallace, Michael P; Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2013-09-17

    Explore compliance with occlusion treatment of amblyopia in the Monitored and Randomized Occlusion Treatment of Amblyopia Studies (MOTAS and ROTAS), using objective monitoring. Both studies had a three-phase protocol: initial assessment, refractive adaptation, and occlusion. In the occlusion phase, participants were instructed to dose for 6 hours/day (MOTAS) or randomized to 6 or 12 hour/day (ROTAS). Dose was monitored continuously using an occlusion dose monitor (ODM). One hundred and fifty-two patients (71 male, 81 female; 122 Caucasian, 30 non-Caucasian) of mean ± SD age 68 ± 18 months participated. Amblyopia was defined as an interocular acuity difference of at least 0.1 logMAR and was associated with anisometropia in 50, strabismus in 44, and both (mixed) in 58. Median duration of occlusion was 99 days (interquartile range 72 days). Mean compliance was 44%, mean proportion of days with no patch worn was 42%. Compliance was lower (39%) on weekends compared with weekdays (46%, P = 0.04), as was the likelihood of dosing at all (52% vs. 60%, P = 0.028). Compliance was lower when attendance was less frequent (P amblyopia type, and severity were not associated with compliance. Mixture modeling suggested three subpopulations of patch day doses: less than 30 minutes; doses that achieve 30% to 80% compliance; and doses that achieve around 100% compliance. This study shows that compliance with patching treatment averages less than 50% and is influenced by several factors. A greater understanding of these influences should improve treatment outcome. (ClinicalTrials.gov number, NCT00274664).

  11. Occlusion and occlusal characteristics of primary dentition in North Indian children of East Lucknow region.

    Science.gov (United States)

    Khan, R; Singh, N; Govil, S; Tandon, S

    2014-10-01

    To determine occlusion and occlusal characteristics of the primary dentition in North Indian school-going children of East Lucknow region. A cross-sectional study was conducted on 453 participants in the age group of 3-6 years. Participants were selected randomly and occlusal relationship was assessed based on Baume's classification. Various other occlusal characteristics were also recorded and assessed based on clinical and photographic evaluation. The data were then subjected to statistical analysis. Out of 453 participants examined, results revealed 62.3% had flush terminal plane; 31.3% mesial step molar relationship and 6.4% distal step molar relationship. It was also observed that 91.6% had Class I canine relationship, 93.4% primate spaces, 69.5% physiologic spaces. Amongst other occlusal characteristics, increased overbite and crowding were prevalent. Association of various occlusal characteristics and oral habits with respect to primary molar relation was also assessed. Chi-square test was performed to carry out statistical analysis. p value plane relationship with spacing and Class I canine relationship predominated. Further prospective studies are required to provide an insight into patterns of occlusal relationship and its changes in Indian children.

  12. Influence of mandibular fixation method on stability of the maxillary occlusal plane after occlusal plane alteration.

    Science.gov (United States)

    Yosano, Akira; Katakura, Akira; Takaki, Takashi; Shibahara, Takahiko

    2009-05-01

    In this study, we investigated how method of mandibular fixation influenced longterm postoperative stability of the maxilla in Class III cases. In particular, we investigated change in the maxillary occlusal plane after Occlusal Plane Alteration. Therefore, we focused on change in the palatal plane to evaluate stability of the maxillary occlusal plane, as the position of the palatal plane affects the maxillary occlusal plane. This study included 16 patients diagnosed with mandibular protrusion. Alteration of the occlusal plane was achieved by clockwise rotation of the maxilla by Le Fort I osteotomy and mandibular setback was performed by bilateral sagittal split ramus osteotomy. We analyzed and examined lateral cephalometric radiographs taken at 1 month, 3 months, 6 months, and 1 year after surgery. Stability achieved by two methods of mandibular fixation was compared. In one group of patients (group S) titanium screws were used, and in the other group (group P) titanium-locking mini-plates were used. No significant displacement was recognized in group S, whereas an approximately 0.7mm upward vertical displacement was recognized in the anterior nasal spine in group P. As a result, not only the angle of the palatal plane and S-N plane, but also occlusal plane angle in group P showed a greater decrease than that in group S. The results suggest that fixing the mandible with screws yielded greater stability of the maxilla and maxillary occlusal plane than fixing the mandible with titanium plates.

  13. Immediate Occlusal versus Non-Occlusal Loading of Implants: A Randomized Clinical Pilot Study.

    Science.gov (United States)

    Vogl, Susanne; Stopper, Marlene; Hof, Markus; Wegscheider, Walther A; Lorenzoni, Martin

    2015-06-01

    Immediate occlusal and non-occlusal loading protocols have been discussed and, despite varying success rates, are considered viable in selected cases. Preoperative implant planning and intraoperative transfer are essential to the success of implant-supported reconstructions in partially or completely edentulous jaws. This study was performed to compare clinical outcomes of immediate occlusal versus non-occlusal loading of posterior implants. Of 19 patients with 52 screw-type implants replacing mandibular molars or premolars, nine patients with 21 implants were randomized to a study group that received immediate restorations with occlusal loading, whereas 10 patients with 31 implants were randomized to a control group that received provisional restorations without occlusal loading. Occlusal loading was defined as full loading in maximum intercuspidation. Single-tooth or splinted multiunit restorations were incorporated by screw retention or cementation. Marginal bone defects (MBD), implant survival, and implant success were evaluated 12 months after insertion. Both groups revealed similar MBD levels consistent with previous reports. No implants were lost (overall survival: 100%) or found to fail (overall success: 100%). No significant intergroup differences were noted for any of the evaluated parameters. Immediate restorations in partially edentulous mandibles demonstrated successful clinical and radiographic 12-month results. Larger long-term prospective studies are needed to confirm the final evidence and predictability of immediate functional loading as a standard treatment concept for partially edentulous jaws. © 2013 Wiley Periodicals, Inc.

  14. Management of occlusal canting with miniscrews.

    Science.gov (United States)

    Yáñez-Vico, Rosa Maria; Iglesias-Linares, Alejandro; Cadenas de Llano-Pérula, Maria; Solano-Reina, Alvaro; Solano-Reina, Enrique

    2014-07-01

    A 14-year-old boy with a skeletal Class II malocclusion and open bite whose chief complaint was a posterior crossbite showed a canted occlusal plane with asymmetric gummy smile and mandibular deviation at clinical examination. The treatment with miniscrews focused on the bilateral intrusion of the maxillary posterior teeth and, after resolving the open bite, a new biomechanical technique involving joined miniscrews was applied for an en masse intrusion of the left side. This treatment strategy achieved optimal occlusion with improvements to the sagittal, vertical, and transverse relationships and achieved a harmonious smile.

  15. Occlusal Characteristics of the Primary Dentition Revisited.

    Science.gov (United States)

    Alexander, Stanley A; Askari, Marjan; Lewis, Patricia

    2015-11-01

    The occlusal characteristics of the primary dentition of 130 children 3 to 6 years old were examined. Variables were the terminal plane relationship, primary canine occlusion, spacing, overjet and overbite relationships. The flush terminal plane was the most common finding. A Class I relationship of the primary canine occurred in 85% of the subjects. Spaced dentitions occurred 81% of the time, while the presence of primate spaces occurred in at least one of the four quadrants. The overjet relationship varied from +1 mm to 4 mm in all subjects, and the majority of children were considered to have a normal overbite.

  16. Strain gauge analysis of occlusal forces on implant prostheses at various occlusal heights.

    Science.gov (United States)

    Cho, Young-Eun; Park, Eun-Jin; Koak, Jai-Young; Kim, Seong-Kyun; Heo, Seong-Joo; Park, Ji-Man

    2014-01-01

    The purpose of this study was to evaluate and compare the strain development at different occlusal heights of an implant prosthesis and adjacent teeth through the use of strain gauges. A test model was constructed using autopolymerizing polyurethane resin, artificial composite resin teeth, and an implant gold crown in the mandibular first molar area. The resin block containing the implant and the gold crown was sectioned, and two expansion screws were attached perpendicular to the bottom of the resin block on the buccal and lingual sides. The expansion screws were turned to create a gap. Four groups were created based on the occlusal height of the implant gold crown. Three strain gauges were attached to the buccal surfaces of the mandibular right second premolar, implant gold crown, and second molar. Beef jerky, carrot, and bread were used as test foods. A universal testing machine was used to apply compressive forces of 300 N (beef jerky), 250 N (carrot), and 50 N (bread), and the occlusal force was measured in each group. With 300 N, occlusal forces were concentrated on the adjacent teeth when the occlusal height of the implant prosthesis decreased. With 250 and 50 N, when the occlusal height of the implant prosthesis increased, the occlusal force applied to the implant prosthesis increased, but alterations in the implant crown height had little effect on the adjacent teeth. Different amounts of strain in the implant prosthesis and adjacent teeth were recorded depending on the occlusal height of the prosthesis. With 250 or 50 N of force, an increased prosthesis height affected the implant itself. With 300 N of force, decreased occlusal height of the prosthesis resulted in increased force on the adjacent teeth.

  17. Kinetics of the oxidation of Zn foils in air atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Baca, R; Martinez, J [Centro de Investigacion de Dispositivos Semiconductores, BUAP, Puebla. C.P. 72570 (Mexico); Kryshtab, T [Departamento de Ciencias de Materiales, ESFM - IPN, Mexico D.F (Mexico); Juarez, G; Solache, H; Andraca, J; Garcia, O; Pena-Sierra, R, E-mail: rbaca02006@yahoo.com.mx

    2010-02-15

    The formation kinetics of ZnO thin films grown by oxidation of polycrystalline Zn foils in air atmosphere at temperatures below the melting point is reported. Previous to the oxidation process the Zn foils were polished to produce mirror-like finished surfaces. The growth rate of the ZnO films was monitored by ellipsometric measurements. The growth rate of the ZnO films under 100 nm follows a linear and parabolic behavior in accordance with previously reported studies. The thicknesses of the films strongly influence the appearance of the final produced ZnO surface. The ZnO films surfaces with thicknesses less than 100 nm resulted uniform with low rms roughness. However as the films become thicker the rms roughness increased and a uniform distribution of whiskers was observed. X-ray diffraction and photoluminescence (PL) studies were done on the ZnO films to find out their structural and optical characteristics. PL spectra on the films are composed by two main bands; a weak near-band gap in the ultraviolet region and a strong but well defined green band. A discussion is included on the origins of the observed PL spectra.

  18. Modelling Accumulator Stripper Foil Heating for ESSNUSB Facility

    CERN Document Server

    Martini, Michel

    2015-01-01

    It is proposed to use the 2.0 GeV, 5 MW proton linac, 2.86 ms long pulses at 14 Hz of the European Spallation Source [1], [2] being built in Lund, Sweden to deliver, alternately with the spallation neutron production a very intense neutrino beam to enable the discovery of leptonic CP violation. To this end the linac would be upgraded to supply, in addition to the 2.86 ms long proton pulses at 14 Hz, four 0.72 ms H short pulses at 70 Hz for neutrino production. Because of the high current required in the pulsed neutrino horn, the length of the pulses used for neutrino production will need to be compressed to a few s with the aid of an accumulator ring. Charge exchange injection of an H- beam from the linac will be used, the linac delivering 1.1E15 H- per pulse. This paper is about stripping foil heating considerations, emphasizing the detailed evaluation of the foil temperature over the multiple ring re-fills

  19. Effect of defence response time during lunge in foil fencing.

    Science.gov (United States)

    Gutiérrez-Cruz, Carmen; Rojas, F Javier; Gutiérrez-Davila, Marcos

    2016-01-01

    The aim of this study was to analyse the effect of stimulus change timing on reaction response time parameters, horizontal velocity of the centre of mass (CM) and precision during offensive actions in fencing. Twelve fencers from the Spanish National Foil Team were included in the study. Two 500 Hz force plates were used to register the horizontal component of the reaction force while a 3D video camera set at 250 Hz recorded the spatial position of 11 body markers and a projector connected to a programmed stopwatch projected a moving target (stimulus) on a screen. When the circle (target) appeared in the centre of the plastron, fencers had to execute a step-forward-lunge as fast as possible, trying to touch the circle with the tip of the foil. During the lunge, the position of the target could randomly shift or not to three different positions. The stimulus change was performed randomly at four different times with a progressive delay. The results show that target changes did not have any effect when they occurred at the beginning of the movement sequence. However, when the target change was delayed, reaction and movement times increased and the technical execution of the lunge changed, leading to more errors.

  20. Pengaruh Posisi Foil Terhadap Gaya Angkat Dan Hambatan Kapal Katamaran

    Directory of Open Access Journals (Sweden)

    Muhammad Rizki Darmawan Adi Kusuma

    2017-08-01

    Full Text Available Perkembangan teknologi dalam dunia perkapalan terjadi sangat pesat, mulanya kapal memiliki satu lambung (monohull, kemudian berkembang dengan munculnya kapal katamaran atau memiliki dua lambung, kapal katamaran memiliki banyak kelebihan dibanding dengan monohull mulai dari segi hambatan, olah gerak, dan lain-lain. Kapal katamaran akhirnya dikembangkan lagi dengan menjadikannya kapal hydrofoil yang bertujuan untuk mengurangi hambatan. Hydrofoil adalah sebuah kapal dengan bagian seperti sayap yang dipasang pada penyangga di bawah lambung kapal yang digunakan untuk mengangkat lambung kapal, pada saat kapal mencapai kecepatan tinggi yang menyebabkan pengurangan hambatan. Pada penelitian ini bertujuan untuk mendapatkan konfigurasi posisi foil yang menghasilkan gaya angkat paling besar serta hambatan yang paling kecil. Dalam melaksanakan penelitian ini penulis menggunakan program komputer berbasis Computational Fluid Dynamic(CFD untuk penyelesaian masalah dari tujuan penelitian, Computational fluid dynamic(CFD merupakan ilmu sains dalam penentuan penyelesaian numerik dinamika fluida.Penelitian dilakukan dengan cara menganalisa dan menghitung hambatan total kapal menggunakan model.Berdasarkan hasil analisa menggunakan software Tdyn 12.2.3.0 didapatkan nilai hambatan untuk berbagai variasi konfigurasi foil. Nilai hambatan total dapat diperkecil  hingga 37,56%, nilai ini terjadi pada Froude Number 1,737 pada variasi konfigurasi Canard dengan konfigurasi 65%(aft dan 35%(fore.

  1. System requirements for the Los Alamos foil-implosion project

    International Nuclear Information System (INIS)

    Brownell, J.; Bowers, R.; Greene, A.; Lindemuth, I.; Nickel, G.; Oliphant, T.; Weiss, D.

    1983-01-01

    The goal of the Los Alamos imploding foil project is the development of an intense source of soft x rays and hot plasma produced from the thermalization of 1 to 10 MJ of plasma kinetic energy. The source will be used for material studies and fusion experiments. Specifically, thin, current-carrying cylindrical metallic plasmas are imploded via their self-magnetic forces. Features of this project are the use of high-explosive-driven flux-compression generators as the prime power source to achieve very high energies and fast opening switches to shorten the electrical pulses. To reach a load kinetic energy of 10 MJ, it is expected that the foil-plasma must carry about 50 MA of current and must implode in less than 1/2 μsec. This imposes the requirements that switch opening times must be less than 1/2 μsec and the transmission line must withstand voltages of about 1 MV. The system being pursued at Los Alamos is described, and model calculations are presented

  2. Kinetics of the oxidation of Zn foils in air atmosphere

    Science.gov (United States)

    Baca, R.; Juárez, G.; Solache, H.; Andraca, J.; Martinez, J.; Garcia, O.; Kryshtab, T.; Peña-Sierra, R.

    2010-02-01

    The formation kinetics of ZnO thin films grown by oxidation of polycrystalline Zn foils in air atmosphere at temperatures below the melting point is reported. Previous to the oxidation process the Zn foils were polished to produce mirror-like finished surfaces. The growth rate of the ZnO films was monitored by ellipsometric measurements. The growth rate of the ZnO films under 100 nm follows a linear and parabolic behavior in accordance with previously reported studies. The thicknesses of the films strongly influence the appearance of the final produced ZnO surface. The ZnO films surfaces with thicknesses less than 100 nm resulted uniform with low rms roughness. However as the films become thicker the rms roughness increased and a uniform distribution of whiskers was observed. X-ray diffraction and photoluminescence (PL) studies were done on the ZnO films to find out their structural and optical characteristics. PL spectra on the films are composed by two main bands; a weak near-band gap in the ultraviolet region and a strong but well defined green band. A discussion is included on the origins of the observed PL spectra.

  3. Monte Carlo transport of electrons and positrons through thin foils

    International Nuclear Information System (INIS)

    Legarda, F.; Idoeta, R.

    2000-01-01

    In the different measurements made with electrons traversing matter it becomes useful the knowledge of its transmission through that medium, their paths and their angular distribution through matter so as to process and get information about the traversed medium and to improve and innovate the techniques that employ electrons, as medical applications or materials irradiation. This work presents a simulation of the transport of beams of electrons and positrons through thin foils using an analog Monte Carlo code that simulates in a detailed way every electron movement or interaction in matter. As those particles penetrate thin absorbers it has been assumed that they interact with matter only through elastic scattering, with negligible energy loss. This type of interaction has been described quite precisely because its angular form influences very much the angular distribution of electrons and positrons in matter. With this code it has been calculated the number of particles, with energies between 100 and 3000 keV, that are transmitted through different media of various thicknesses as well as its angular distribution, showing a good agreement with experimental data. The discrepancies are less than 5% for thicknesses lower than about 30% of the corresponding range in the tested material. As elastic scattering is very anisotropic, angular distributions resemble a collimated incident beam for very thin foils becoming slowly more isotropic when absorber thickness is increased. (author)

  4. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    Science.gov (United States)

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  5. Crossing Total Occlusions : Navigating Towards Recanalization

    NARCIS (Netherlands)

    Sakes, A.; Regar, E.; Dankelman, J.; Breedveld, P.

    2016-01-01

    Chronic total occlusions (CTOs) represent the “last frontier” of percutaneous interventions. The main technical challenges lies in crossing the guidewire into the distal true lumen, which is primarily due to three problems: device buckling during initial puncture, inadequate visualization, and the

  6. Crossing Total Occlusions: Navigating Towards Recanalization

    NARCIS (Netherlands)

    A. Sakes (Aimée); E.S. Regar (Eveline); J. Dankelman (Jenny); P. Breedveld (Paul)

    2016-01-01

    textabstractChronic total occlusions (CTOs) represent the “last frontier” of percutaneous interventions. The main technical challenges lies in crossing the guidewire into the distal true lumen, which is primarily due to three problems: device buckling during initial puncture, inadequate

  7. Combined central retinalartery and vein occlusion complicating ...

    African Journals Online (AJOL)

    Orbital Cellulitis is a dreaded ophthalmologic disease. Itmay destroy vision and the eye andmay even become life threatening. Often visual loss is the result of exposure and subsequent destruction of ocular tissue commonly the cornea and the uvea. We report a case of combined central retinal artery and vein occlusion ...

  8. Class II malocclusion occlusal severity description

    Directory of Open Access Journals (Sweden)

    Guilherme Janson

    2010-08-01

    Full Text Available OBJECTIVES: It is well known that the efficacy and the efficiency of a Class II malocclusion treatment are aspects closely related to the severity of the dental anteroposterior discrepancy. Even though, sample selection based on cephalometric variables without considering the severity of the occlusal anteroposterior discrepancy is still common in current papers. In some of them, when occlusal parameters are chosen, the severity is often neglected. The purpose of this study is to verify the importance given to the classification of Class II malocclusion, based on the criteria used for sample selection in a great number of papers published in the orthodontic journal with the highest impact factor. MATERIAL AND METHODS: A search was performed in PubMed database for full-text research papers referencing Class II malocclusion in the history of the American Journal of Orthodontics and Dentofacial Orthopedics (AJO-DO. RESULTS: A total of 359 papers were retrieved, among which only 72 (20.06% papers described the occlusal severity of the Class II malocclusion sample. In the other 287 (79.94% papers that did not specify the anteroposterior discrepancy severity, description was considered to be crucial in 159 (55.40% of them. CONCLUSIONS: Omission in describing the occlusal severity demands a cautious interpretation of 44.29% of the papers retrieved in this study.

  9. Clinical Aspects of Combination of Ceramic and Acrylic Occlusal Surfaces

    Directory of Open Access Journals (Sweden)

    Z. Ozhohan

    2017-03-01

    Full Text Available The objective of the research was to develop and substantiate the methods of constructing the occlusal surfaces when manufacturing aesthetic fixed restorations through the combination of different materials. Materials and methods. The study included 65 patients with ceramic and acrylic occlusal surfaces of aesthetic fixed dental prostheses. Group I included 21 patients with a combination of ceramic and acrylic occlusal surfaces. Group II included 22 patients with a combination of ceramic occlusal surfaces. Group III included 22 patients with a combination of acrylic occlusal surfaces. The patients were observed 3, 6 and 12 months after prosthetic repair. Results. The greatest increase in the occlusal contact surface area of fixed restorations was observed in Group I, that is, when combining dental prostheses with ceramic and acrylic occlusal surfaces. Considering uneven abrasion of the occlusal surfaces, we do not recommend to combine different materials when veneering the occlusal surface of the antagonistic teeth. Conclusions. This study demonstrated the important role of the correct combination of materials when veneering the occlusal surfaces. Physical and chemical properties of materials, namely the abrasion resistance play a significant role in the long-term denture functioning. The smallest increase in the occlusal contact surface area was observed in Group II when combining ceramic occlusal surfaces. It was due to a good abrasion resistance of ceramics as compared to acrylic resin as well as the presence of the glazed layer which prevents the premature abrasion of the occlusal surfaces of the antagonistic teeth due to lower surface roughness. The combination of acrylic resin and ceramics when constructing the occlusal surfaces of fixed restorations in Group I demonstrated the highest rate of the increase in the occlusal contact surface area – 9.93%. It was due to a low hardness of acrylic resin and its high surface roughness. In

  10. Temporomandibular Disorders Treatment with Correction of Decreased Occlusal Vertical Dimension

    OpenAIRE

    Guguvcevski, Ljuben; Gigovski, Nikola; Mijoska, Aneta; Zlatanovska, Katerina; Arsova-Gigovska, Ana

    2017-01-01

    BACKGROUND: The term decreased occlusal vertical dimension refers to the reduced distance between two anatomical points while the teeth are in a state of occlusion. The development of this situation is about some parafunctional activities of the masticatory system. AIM: To evaluate the value of decreased occlusal vertical dimension in cases with temporomandibular disorder and to follow up the influence of corrective treatment with occlusal splints and definitive prosthetic construction up...

  11. Optimizing dc-resistance of a foil wounded toroidal inductor combining matlab and comsol

    DEFF Research Database (Denmark)

    Schneider, Henrik; Andersen, Thomas; Knott, Arnold

    2013-01-01

    An optimization routine is presented to optimize the shape of a foil winding of a toroid inductor in terms of the DC resistance. MATLAB was used to define the geometry of the foil winding and COMSOL was used to import the geometry and create a 3D finite element model. The initial parameters...

  12. Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics

    Science.gov (United States)

    Planinsic, Gorazd; Gojkosek, Mihael

    2011-01-01

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…

  13. Large area flexible lighting foils using distributed bare LED dies on polyester substrates

    NARCIS (Netherlands)

    Ende, D.A. van den; Kusters, R.H.L.; Cauwe, M.; Waal, A. van der; Brand, J. van den

    2013-01-01

    Integration of LEDs on flexible foil substrates is of interest for flexible lighting applications and for backlights for flexible displays. Such a large area lighting device can be made by integrating a matrix of closely spaced LEDs on a flexible foil substrate. Preferably, these LEDs are integrated

  14. Vortex-wake interactions of a flapping foil that models animal swimming and flight

    NARCIS (Netherlands)

    Lentink, D.; Muijres, F.T.; Donker-Duyvis, F.J.; Leeuwen, van J.L.

    2008-01-01

    The fluid dynamics of many swimming and flying animals involves the generation and shedding of vortices into the wake. Here we studied the dynamics of similar vortices shed by a simple two-dimensional flapping foil in a soap-film tunnel. The flapping foil models an animal wing, fin or tail in

  15. Long-Term Memory for Pictures under Conditions of Difficult Foil Discriminability.

    Science.gov (United States)

    Homa, Donald; Viera, Cynthia

    Research has demonstrated that subjects are sensitive to both thematic and non-thematic information in pictorial stimuli. Three experiments were conducted to investigate memory for pictures under conditions of difficult foil discriminability and lengthy retention intervals. The foils differed from the studied persons in the number and quality of…

  16. Bonding bare die LEDs on PET foils for lighting applications: Thermal design modeling and bonding experiments

    NARCIS (Netherlands)

    Ende, D.A. van den; Kusters, R.H.L.; Cauwe, M.; Waal, A. van der; Brand, J. van den

    2012-01-01

    Integration of LEDs on flexible foil substrates is of interest for flexible lighting applications and flexible photonic devices. A matrix of LEDs on a foil combined with a diffuser can be a potential alternative for flexible OLED lighting devices. Preferably, these LEDs are integrated in an

  17. Corrections in the gold foil activation method for determination of neutron beam density

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage

    1967-01-01

    A finite foil thickness and deviation in the cross section from the 1ν law imply corrections in the determination of neutron beam densities by means of foil activation. These corrections, which depend on the neutron velocity distribution, have been examined in general and are given in a specific...

  18. Identification of stiffness and damping characteristics of axial air-foil bearings

    NARCIS (Netherlands)

    Arora, Vikas; Arora, Vikas; van der Hoogt, Peter; Aarts, Ronald G.K.M.; de Boer, Andries

    2011-01-01

    Air-foil bearings (AFBs) are self acting hydrodynamic bearings made from sheet metal foils comprised of at least two layers. The innermost “top foil” layer traps a gas pressure film that supports a load while the layer or layers underneath provide an elastic foundation. AFBs are currently used in

  19. Compositional characterization of thin foil by instrumental heavy ion activation analysis

    International Nuclear Information System (INIS)

    Chowdhury, D.P.; Pal, Sujit; Guin, R.; Saha, S.K.; Venkataramani, B.

    2007-01-01

    The elemental composition of a thin (2 mm) Havar foil was determined by instrumental heavy ion activation analysis (HIAA). The recoiled products, coming out of thin target, were separated and absorbed in graded thickness of aluminum catcher foils as per their recoil ranges. Activation technique was followed for the quantitative estimation using elemental standards by comparator technique. (author)

  20. Occlusal Plane Orientor”: An Innovative and Efficient Device for Occlusal Plane Orientation

    OpenAIRE

    Kuniyal, Harish; Katoch, Nidhi; Rao, P. Laxman

    2011-01-01

    Correct occlusal plane orientation is a prerequisite in Prosthodontic reconstructive treatment therapy as it helps in achieving esthetics and phonetics anteriorly and forms a milling surface posteriorly where tongue and buccinator muscle position the food bolus during mastication. Activity of Muscles during clenching will be least, when the occlusal plane is made parallel to plane of lost natural teeth. Conventionally the ala-tragus line (Camper’s plane) is used as a guide for assessment of t...

  1. Reversal of myopic Anisometropic amblyopia with occlusion therapy ...

    African Journals Online (AJOL)

    Objective: To report a reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old. Design: Case report. Setting: Eye clinic of a University Teaching Hospital in a metropolitan city. Participant: an index patient. Intervention: Occlusion therapy. Main Outcome Measure: Post occlusion visual acuity.

  2. Occlusion invariant face recognition using mean based weight ...

    Indian Academy of Sciences (India)

    Features obtained from the corresponding occlusion-free patches of training images are used for face image recognition. The SVM classifier is used for occlusion detection for each patch. In the recognition phase, the MBWM bases of occlusion-free image patches are used for face recognition. Euclidean nearest neighbour ...

  3. Digital assessment of occlusal wear patterns on occlusal stabilization splints: a pilot study.

    Science.gov (United States)

    Korioth, T W; Bohlig, K G; Anderson, G C

    1998-08-01

    If masticatory load distribution is task-dependent, then the pattern of wear on an acrylic resin occlusal splint over time may affect clinical outcome. This pilot study quantitatively assessed posterior wear after 3 months on the occlusal surfaces of maxillary stabilization splints. Subjects with known history of nocturnal bruxism were given heat-cured full-arch acrylic resin occlusal stabilization splints to be worn nocturnally for 3 months. Splint occlusion was adjusted at appliance delivery and was refined at the baseline session 1 to 2 weeks later. No further adjustment of the splint surface was performed during the 3-month study period. Sequential impressions of the splint occlusal surface provided epoxy resin models that were digitized and analyzed through specialized software. Changes in the digitized splint surface from baseline to 3 months allowed comparison of wear facets between splint sides and among tooth locations. Splint wear was asymmetric between sides and uneven between dental locations. For full coverage occlusal splints, the appliance wear phenomenon can be site specific and, if left undisturbed, may yield two extremes of high wear and a zone of low wear in-between.

  4. Irradiation tests of 99Mo isotope production targets employing uranium metal foils

    International Nuclear Information System (INIS)

    Hofman, G.L.; Wiencek, T.C.; Wood, E.L.; Snelgrove, J.L.; Suripto, A.; Nasution, H.; Lufti-Amin, D.; Gogo, A.

    1996-01-01

    Most of the world's supply of 99 mTc for medical purposes is currently produced from the decay of 99 Mo derived from the fissioning of high-enriched uranium (HEU). Substitution of low-enriched uranium (LEU) metal foils for the HEU UO 2 used in current target designs will allow equivalent 99 Mo yields with little change in target geometries. Substitution of uranium metal for uranium alloy and aluminide in other target designs will also allow the conversion of HEU to LEU. Several uranium-metal-foil targets have been fabricated at ANL and irradiated to prototypic burnup in the Indonesian RSG-GAS reactor. Postirradiation examination of the initial test indicated that design modifications were required to allow the irradiated foil to be removed for chemical processing. The latest test has shown good irradiation behavior, satisfactory dismantling and foil removal when the U-foil is separated from its containment by metallic, fission-recoil absorbing barriers. (author)

  5. Foil assisted replica molding for fabrication of microfluidic devices and their application in vitro.

    Science.gov (United States)

    Micheal, Issac J; Vidyasagar, Aditya J; Bokara, Kiran Kumar; Mekala, Naveen Kumar; Asthana, Amit; Rao, Ch Mohan

    2014-10-07

    We present a simple, rapid, benchtop, Foil Assisted Rapid Molding (FARM) method for the fabrication of microfluidic devices. This novel technique involves the use of aluminium foil, pen and an X-Y plotter to create semi-circular or plano-concave, shallow microchannels. It is an easy do-it-yourself (DIY) technique for creating a microfluidic device in three simple steps: (1) create a channel design using the CAD software, (2) plot the patterns on aluminium foil and (3) use the reverse of the engraved foil as a mold to create microfluidic devices. In this report, we present a detailed study of the proposed method by varying a range of parameters such as foil thickness, tip material, and tip sizes and by investigating their effect on the creation of channels with varying geometry. Furthermore, we demonstrated the cytocompatibility of these devices in vitro.

  6. Lead foil in dental X-ray film: Backscattering rejection or image intensifier?

    Energy Technology Data Exchange (ETDEWEB)

    Hönnicke, M.G., E-mail: marcelo.honnicke@unila.edu.br [Universidade Federal da Integração Latino-Americana, Foz do Iguaçu (Brazil); Delben, G.J. [Faculdade de Tecnologia Tupy, Curitiba (Brazil); Godoi, W.C. [Universidade Tecnológica Federal do Paraná, Curitiba (Brazil); Swinka-Filho, V. [Instituto de Tecnologia para o Desenvolvimento – LACTEC, Curitiba (Brazil)

    2014-11-01

    Dental X-ray films are still largely used due to sterilization issues, simplicity and, mainly, economic reasons. These films almost always are double coated (double emulsion) and have a lead foil in contact with the film for X-ray backscattering rejection. Herein we explore the use of the lead foil as an image intensifier. In these studies, spatial resolution was investigated when images were acquired on the dental X-ray films with and without the lead foil. Also, the lead foil was subjected to atomic analysis (fluorescent measurements) and structure analysis (X-ray diffraction). We determined that the use of the lead foil reduces the exposure time, however, does not affect the spatial resolution on the acquired images. This suggests that the fluorescent radiation spread is smaller than the grain sizes of the dental X-ray films.

  7. Room temperature thin foil SLIM-cut using an epoxy paste: experimental versus theoretical results

    International Nuclear Information System (INIS)

    Bellanger, Pierre; Serra, Joao; Bouchard, Pierre-Olivier; Bernacki, Marc

    2015-01-01

    The stress induced lift-off method (SLIM) -cut technique allows the detachment of thin silicon foils using a stress inducing layer. In this work, results of SLIM-cut foils obtained using an epoxy stress inducing layer at room temperature are presented. Numerical analyses were performed in order to study and ascertain the important experimental parameters. The experimental and simulation results are in good agreement. Indeed, large area (5 × 5 cm 2 ) foils were successfully detached at room temperature using an epoxy thickness of 900 μm and a curing temperature of 150 °C. Moreover, three foils (5 × 3 cm 2 ) with thickness 135, 121 and 110 μm were detached from the same monocrystalline substrate. Effective minority carrier lifetimes of 46, 25 and 20 μs were measured using quasi-steady-state photoconductance technique in these foils after iodine ethanol surface passivation. (paper)

  8. Nondestructive analysis of silver in gold foil using synchrotron radiation X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Kasamatsu, Masaaki; Suzuki, Yasuhiro; Suzuki, Shinichi; Nakanishi, Toshio; Shimoda, Osamu; Nishiwaki, Yoshinori; Miyamoto, Naoki

    2005-01-01

    Small particles of gold foil detached from an indoor decoration might be important evidence to associate a suspect with a crime scene. We have investigated the application of elemental analysis using synchrotron radiation X-ray fluorescence spectrometry to discriminate small particles of gold foil. Eight kinds of gold foil samples collected in Japan were used in the experiments. As a result of synchrotron radiation X-ray fluorescence spectrometry, only two elements, gold and silver, were detected from all gold foil samples. The intensity ratios of AgK α /AuL α showed good correlation with the content ratios of Ag/Au. The variation of intensity ratio within a same sample was sufficiently small compared with those of different samples. Therefore the comparison of this intensity ratio can be an effective method to discriminate small particles originating from different types of gold foil. (author)

  9. Design, fabrication, and performance of foil journal bearing for the brayton rotating unit

    Science.gov (United States)

    Licht, L.; Branger, M.

    1973-01-01

    Foil bearings were designed and manufactured to replace pivoted-shoe journal bearings in an existing Brayton Cycle turbo-alternator-compressor. The design of this unconventional rotor support was accomplished within the constraints and space limitations imposed by the present machine, and the substitution of foil bearings was effected without changes or modification other machine components. A housing and a test rig were constructed to incorporate the new foil-bearing support into a unified assemble with an air-driven rotor and the gimbal-mounted thrust bearing, seals, and shrouds of an actual Brayton Rotating Unit. The foil bearing required no external pressure source, and stable self-acting rotation was achieved at all speeds up to 43,200 rpm. Excellent wipe-wear characteristics of the foil bearing permitted well over 1000 start-stop cycles with no deterioriation of performance in the entire speed range.

  10. Irradiation tests of 99Mo isotope production targets employing uranium metal foils

    International Nuclear Information System (INIS)

    Hofman, G.L.; Wiencek, T.C.; Wood, E.L.; Snelgrove, J.L.; Suripto, A.; Nasution, H.; Lufti-Amin, D.; Gogo, A.

    1996-01-01

    Most of the world's supply of 99m Tc for medical purposes is currently produced form the decay of 99 Mo derived from the fissioning of high-enriched uranium (HEU). Substitution of low-enriched uranium (LEU) metal foils for the HEU UO 2 used in current target designs will allow equivalent 99 Mo yields with little change in target geometries. Substitution of uranium metal for uranium alloy and aluminide in other target designs will also allow the conversion of HEU to LEU. Several uranium-metal-foil targets have been fabricated at ANL and irradiated to prototypic burnup in the Indonesian RSG-GAS reactor. Postirradiation examination of the initial test indicated that design modifications were required to allow the irradiated foil to be removed for chemical processing. The latest test has shown good irradiation behavior, satisfactory dismantling and foil removal when the U-foil is separated from its containment by metallic, fission-recoil absorbing barriers

  11. Report on Plasma Spraying of Full-Sized Foils (FY13)

    Energy Technology Data Exchange (ETDEWEB)

    Hollis, Kendall J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-02-27

    This report is the deliverable fulfilling task B40700. The application of the Zr diffusion barrier between the U-­Mo fuel and the Al cladding has been an ongoing area of research [1-8]. The goal of the research described in this report was to demonstrate the plasma spraying technique for depositing zirconium (Zr) onto full sized U-Mo foils to demonstrate scale up of the process from the mini foil samples (1”x4”x ~0.015”) coated previously. Full size denotes one of the actual fuel foil sizes for one of the five research reactors (MURR, NIST, MIT, HFIR, ATR) to be converted to LEU fuel in the US research reactor Convert program. The smallest full sized fuel foil is for the NIST reactor with a size of 11.37”x2.436”x0.020”. The largest full sized fuel foil is for the ATR reactor with a size of 48.01”x3.43”x0.020”. The widest full sized fuel foil is for the MURR reactor with a size of 24”x4.052”x0.020”. The current LANL vacuum plasma spray system can accommodate a foil length of 24” or less. Therefore, as a demonstration of the widest foil in the program and the maximum length foil that can be processed on the current LANL system, a nominal 24”x4”x0.020” foil was chosen as the goal for scale up activities.

  12. Test preparation and lifetime measurement of very thin carbon stripper foils made by a controlled DC arc-discharge method

    CERN Document Server

    Sugai, I; Oyaizu, M; Kawakami, H; Hattori, Y; Kawasaki, K; Hayashizaki, N

    2002-01-01

    We have prepared very thin plastic supported carbon stripper foils (1.2+-0.3 mu g/cm sup 2) using a controlled DC arc-discharge (CDAD) method. The lifetime of these foils was measured with 3.2 MeV Ne sup + ions. These foils recorded lifetimes about four times longer at the maximum and three times longer on the average than those commercially available foils produced by evaporation-condensation.

  13. Gas permeability through thin-foil x-ray filters

    Science.gov (United States)

    Tveekrem, June L.; Keski-Kuha, Ritva A.; Webb, Andrew T.

    1997-10-01

    We have measured the permeation rates of helium and water through thin-foil UV-blocking filters used in the ASTRO-E/x- ray spectrometer (XRS) instrument. In the XRS program, there is a concern that outgassed contaminants such as water could permeate through the outermost filter which will be at room temperature and freeze on the inner filters which will be at cryogenic temperatures. The filters tested consisted of approximately 1000 angstroms Al on approximately 1000 angstroms of either Lexan or polyimide. Measurements were made using a vacuum apparatus consisting essentially of two small chambers separated by the filter under test. A helium leak detector was used to measure helium permeation rates, and a residual gas analyzer (RGA) was used to detect water. Results discussed include permeation rate as a function of pressure difference across a filter, the ratio of helium permeation rate over water permeation rate, and the effect of the aluminum layer thickness on permeation.

  14. New membranes obtained by grafted irradiated PVDF foils

    Energy Technology Data Exchange (ETDEWEB)

    Mazzei, R. [Unidad de Actividades Tecnologicas y Agropecuarias, Laboratorio de Polimeros, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Universidad Tecnologica Nacional Facultad Regional, Buenos Aires (Argentina); Garcia Bermudez, G. [Gerencia de Investigacion y Aplicaciones, Laboratorio Tandar, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Escuela de Ciencia y Tecnologia, Universidad Nacional de General San Martin, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas, Buenos Aires (Argentina); Camporotondi, D.E., E-mail: camporotondi@cae.cnea.gov.ar [Unidad de Actividades Tecnologicas y Agropecuarias, Laboratorio de Polimeros, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Arbeitman, C. [Gerencia de Investigacion y Aplicaciones, Laboratorio Tandar, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas, Buenos Aires (Argentina); and others

    2012-09-15

    The present work describes a new method to produce membranes of poly(Acrylic-acid-Xmonomer) using the grafting procedure. PVDF foils irradiated with Ar{sup +} beam with energies between 30 and 150 keV were employed as substratum. Different combinations of monomers in water solutions were used: acrylic acid (AAc); acrylic acid-glycidyl methacrylate (AAc-GMA); acrylic acid-styrene (AAc-S), acrylic acid-N-isopropyl acrylamide (AAc-NIPAAm) and acrylic acid-N-isopropyl acrylamide-glycidyl methacrylate (AAc-NIPAAm-GMA). A large percentage of grafting results for specific values of: ion fluence and energy, AAc and sulfuric acid concentration, and different substrata PVDF polymorphous (alpha or beta). At a particular time of the grafting process, the poly(AAc-Xmonomer) membranes detach from the substratum and continue their grafting in the solution. This method is useful to produce increased replicated membranes of the irradiated original surface.

  15. Beam-foil spectroscopy of chlorine and sulfur ions

    International Nuclear Information System (INIS)

    Frot, D.; Barchewitz, R.; Cukier, M.; Bruneau, J.

    1987-01-01

    We report on the measurement of spectra of highly stripped chlorine and sulfur ions in the energy ranges of, respectively, 2900 - 3500 eV and 2300 - 2600 eV. The spectra have been obtained after excitation of ions travelling through a thin carbon foil. X-rays emitted by the emerging beam are analysed with a Johann-type bent crystal spectrometer. The observation angle with respect to the beam axis is 54 0 . The interpretation of the spectra is performed by comparing experimental results with Multiconfiguration Dirac-Fock (MCDF) calculated energies and intensities. All the lines are interpreted by 2p - ls transitions (K α spectrum) in excited ions with, respectively, H-, He-, Li-, Be- and B-like electron structures

  16. Synthesis of Homogenous Bilayer Graphene on Industrial Cu Foil

    Science.gov (United States)

    Luo, Wen-Gang; Wang, Hua-Feng; Cai, Kai-Ming; Han, Wen-Peng; Tan, Ping-Heng; Hu, Ping-An; Wang, Kai-You

    2014-06-01

    We synthesize the homogenous graphene films on cheap industrial Cu foils using low pressure chemical vapor deposition. The quality and the number of layers of graphene are characterized by Raman spectra. Through carefully tuning the growth parameters, we find that the growth temperature, hydrocarbon concentration and the growth time can substantially affect the growth of high-quality graphene. Both single and bilayer large size homogenous graphenes have been synthesized in optimized growth conditions. The growth of graphene on Cu surface is found to be self ceasing in the bilayer graphene process with the low solubility of carbon in Cu. Furthermore, we have optimized the transfer process, and clear graphene films almost free from impurity are successfully transferred onto Si/SiO2 substrates. The field effect transistors of bilayer graphene are fabricated, which demonstrates a maximum hole (electron) mobility of 4300 cm2 V-1s-1 (1920 cm2V-1s-1) at room temperature.

  17. Visualization of terahertz surface waves propagation on metal foils

    Science.gov (United States)

    Wang, Xinke; Wang, Sen; Sun, Wenfeng; Feng, Shengfei; Han, Peng; Yan, Haitao; Ye, Jiasheng; Zhang, Yan

    2016-01-01

    Exploitation of surface plasmonic devices (SPDs) in the terahertz (THz) band is always beneficial for broadening the application potential of THz technologies. To clarify features of SPDs, a practical characterization means is essential for accurately observing the complex field distribution of a THz surface wave (TSW). Here, a THz digital holographic imaging system is employed to coherently exhibit temporal variations and spectral properties of TSWs activated by a rectangular or semicircular slit structure on metal foils. Advantages of the imaging system are comprehensively elucidated, including the exclusive measurement of TSWs and fall-off of the time consumption. Numerical simulations of experimental procedures further verify the imaging measurement accuracy. It can be anticipated that this imaging system will provide a versatile tool for analyzing the performance and principle of SPDs. PMID:26729652

  18. Standard test methods of tension testing of metallic foil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1993-01-01

    1.1 These test methods cover the tension testing of metallic foil at room temperature in thicknesses less than 0.006 in. (0.150 mm). Note 1—Exception to these methods may be necessary in individual specifications or test methods for a particular material. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Deposition of selenium coatings on beryllium foils. Revision 1

    International Nuclear Information System (INIS)

    Erikson, E.D.; Tassano, P.L.; Reiss, R.H.; Griggs, G.E.

    1984-01-01

    A technique for preparing selenium films on 50.8 micrometers thick beryllium foils is described. The selenium was deposited in vacuum from a resistance heated evaporation source. A water-cooled enclosure was used to minimize contamination of the vacuum system and to reduce the exposure of personnel to toxic and obnoxious materials. Profilometry measurements of the coatings indicated selenium thicknesses of 5.5, 12.9, 37.5, 49.8 and 74.5 micrometers. The control of deposition rate and of coating thickness was facilitated using a commercially available closed-loop programmable deposition controller. The x-ray transmission of the coated substrates was measured using a tritiated zirconium source. The transmissivities of the film/substrate combination are presented for the range of energies from 4 to 20 keV

  20. [Case report of occlusal treatment with full mouth reconstruction].

    Science.gov (United States)

    Oizumi, Makoto

    2008-07-01

    A 70-year-old woman presented with a complaint of masticatory pain and disturbance. She had collapse of occlusal support and vertical dimension decrease. This case used provisional restoration for increasing vertical dimension and reconstruction of anterior guidance. After confirming occlusal stability, she was treated with fixed prosthesis and removable partial dentures. This patient was followed for 6 and a half years with no prosthetic complications, because the reconstruction of bilateral occlusal support and anterior guidance were performed. It is important to reconstruct the occlusal support and anterior guidance in cases of prosthetic treatment of occlusal collapse.

  1. The foil equilibration method for carbon in sodium

    International Nuclear Information System (INIS)

    Borgstedt, H.; Frees, G.; Peric, Z.

    1980-01-01

    Among the non-metallic impurities in sodium, carbon plays an important role since at high temperatures the structural materials exposed to sodium are subject to carburization and decarburization depending on the carbon activity of the sodium. Carburization of austenitic stainless steels leads to reduction in ductility and fatigue properties whereas decarburization results in a decrease in the high temperature creep strength. A knowledge of the carbon activities in sodium will help understanding of the carbon transfer phenomena in operating sodium systems of the fast reactors, and also carbon diffusion, microstructural stability and mechanical behaviour of materials under different service conditions. An understanding of the carbon behaviour in sodium becomes difficult in view of the complexities of the different species present as elemental carbon, carbide, acetylide, carbonate, and cyanide. Carbon estimation techniques for sodium presently in use are: chemical analytical methods, on-line carbon monitors, and oil equilibration method. Various chemical methods have been developed for the estimation of different species like acetylide, cyanide, carbonate, elemental carbon, and total carbon in sodium. All these methods are time consuming and subject to various errors. The on-line monitors developed for carbon in sodium are able to give continuous indication of carbon activities and have higher sensitivity than the chemical methods. A still more simple method for the determination of carbon activities is by the foil equilibration first published by Natesan et al. Because of its simplicity like the vanadium wire equilibration for oxygen it is being used widely for the estimation of carbon activities in sodium systems. Carbon concentrations in operating sodium systems estimated by this procedure by applying solubility relation to carbon activities have yielded very low values of carbon, lower than the sensitivity limits of the chemical estimation methods. Foil

  2. Influence of copper foil polycrystalline structure on graphene anisotropic etching

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Kamal P. [Department of Frontier Materials, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Mahyavanshi, Rakesh D. [Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Kalita, Golap, E-mail: kalita.golap@nitech.ac.jp [Department of Frontier Materials, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Tanemura, Masaki [Department of Frontier Materials, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan); Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555 (Japan)

    2017-01-30

    Graphical abstract: Hexagonal hole formation with anisotropic etching independent of the stripes and wrinkles in the synthesized graphene. We also observed variation in etched pattern of the graphene depending on the base Cu grain orientations, attributing to difference in nucleation and growth process. - Highlights: • Reveal the influence of copper polycrystalline structure on anisotropic etching of graphene. • Hexagonal hole formation with etching is observed to be independent of stripes and wrinkles in graphene. • Variation in etched pattern of graphene depending on the base Cu grain is confirmed. • This finding will help to understand the nature of microscopic etched pattern in graphene. - Abstract: Anisotropic etching of graphene and other two dimensional materials is an important tool to understand the growth process as well as enabling fabrication of various well-defined structures. Here, we reveal the influence of copper foil polycrystalline structure on anisotropic etching process of as-synthesized graphene. Graphene crystals were synthesized on the polycrystalline Cu foil by a low-pressure chemical vapor deposition (LPCVD) system. Microscopic analysis shows difference in shape, size and stripes alignment of graphene crystals with dissimilar nucleation within closure vicinity of neighboring Cu grains. Post-growth etching of such graphene crystals also significantly affected by the crystallographic nature of Cu grains as observed by the field emission scanning electron microscope (FE-SEM) and electron back scattered diffraction (EBSD) analysis. Hexagonal hole formation with anisotropic etching is observed to be independent of the stripes and wrinkles in the synthesized graphene. We also observed variation in etched pattern of the graphene depending on the base Cu grain orientations, attributing to difference in nucleation and growth process. The findings can facilitate to understand the nature of microscopic etched pattern depending on metal

  3. Concepts of occlusion in prosthodontics: A literature review, part I

    Directory of Open Access Journals (Sweden)

    V Rangarajan

    2015-01-01

    Full Text Available Occlusion and its relationship to the function of the stomatognathic system have been widely studied in dentistry since many decades. This series of articles describe about occlusion in the complete denture, fixed partial denture, and implants. Part I and II of this articles series describe concepts and philosophies of occlusion in complete denture. So far, available research has not concluded a superior tooth form or occlusal scheme to satisfy the requirements of completely edentulous patients with respect to comfort, mastication, phonetics, and esthetics. Since then, several balanced and nonbalanced articulation concepts were proposed in the literature. A balanced articulation appears to be most appropriate because of tooth contacts observed during nonfunctional activities of patients. This article discusses about evolution of different concepts of occlusion and occlusal schemes in complete denture occlusion.

  4. [Study on retention and stability of linear occlusal complete dentures].

    Science.gov (United States)

    Zhang, Ping; Xu, Jun

    2003-01-01

    To learn retention and stability of linear occlusal complete dentures by investigating the subjective feelings of patient and the value of retention force. Static retention forces of maxillary and mandibular dentures were measured for 25 patients wearing linear occlusal dentures by using Hz-1 retention dynamometer. The subjective feelings of patients in functional state were gained simultaneously through questionnaire. Linear occlusal dentures demonstrate good retention in static and dynamic state. Among patients with severe resorption of residual ridge (RRR), mandibular linear occlusal dentures (shown good retentive subjective feelings) demonstrate significantly smaller retention force than those with slight or medium degree of RRR. There is no correlation between the subjective feelings and the values of retention forces of mandibular dentures. The subjective feelings of patients wearing new linear occlusal dentures are much better than that of old anatomic occlusal dentures. Linear occlusal dentures improve the performances of dentures by enhancing their stability during mastication movement.

  5. Restoration of posterior teeth using occlusal matrix technique

    Directory of Open Access Journals (Sweden)

    Martos Josue

    2010-01-01

    Full Text Available This article describes a technique for duplicating occlusal surface anatomy using the Biteperf device. Duplication requires an intact occlusal enamel surface and is only indicated when caries lesions are hidden. The occlusal matrix technique allows for preservation of all anatomic details. When the last layer of composite has been placed, the occlusal matrix is forced into the uncured composite to replicate the original occlusal surface, instead of performing manual curing and shaping as in the standard approach. It is technically possible to achieve this effect with any material that is able to copy anatomic details. The main benefits of the occlusal matrix technique, more precisely the Biteperf, are the technical ease of use due to its simplicity and its high accuracy in reconstructing occlusal morphology.

  6. RTSAH Traversal Order for Occlusion Rays

    KAUST Repository

    Ize, Thiago

    2011-04-01

    We accelerate the finding of occluders in tree based acceleration structures, such as a packetized BVH and a single ray kd-tree, by deriving the ray termination surface area heuristic (RTSAH) cost model for traversing an occlusion ray through a tree and then using the RTSAH to determine which child node a ray should traverse first instead of the traditional choice of traversing the near node before the far node. We further extend RTSAH to handle materials that attenuate light instead of fully occluding it, so that we can avoid superfluous intersections with partially transparent objects. For scenes with high occlusion, we substantially lower the number of traversal steps and intersection tests and achieve up to 2× speedups. © 2010 The Author(s).

  7. Handling Occlusions for Robust Augmented Reality Systems

    Directory of Open Access Journals (Sweden)

    Maidi Madjid

    2010-01-01

    Full Text Available Abstract In Augmented Reality applications, the human perception is enhanced with computer-generated graphics. These graphics must be exactly registered to real objects in the scene and this requires an effective Augmented Reality system to track the user's viewpoint. In this paper, a robust tracking algorithm based on coded fiducials is presented. Square targets are identified and pose parameters are computed using a hybrid approach based on a direct method combined with the Kalman filter. An important factor for providing a robust Augmented Reality system is the correct handling of targets occlusions by real scene elements. To overcome tracking failure due to occlusions, we extend our method using an optical flow approach to track visible points and maintain virtual graphics overlaying when targets are not identified. Our proposed real-time algorithm is tested with different camera viewpoints under various image conditions and shows to be accurate and robust.

  8. Nontraumatic vascular emergencies: imaging and intervention in acute venous occlusion

    International Nuclear Information System (INIS)

    Haage, Patrick; Schmitz-Rode, Thomas; Krings, Timo

    2002-01-01

    Risk factors for acute venous occlusion range from prolonged immobilization to hypercoagulability syndromes, trauma, and malignancy. The aim of this review article is to illustrate the different imaging options for the diagnosis of acute venous occlusion and to assess the value of interventional strategies for venous thrombosis treatment in an emergency setting. First, diagnosis and treatment of the most common form of venous occlusion, at the level of the lower extremities, is presented, followed by pelvic vein and inferior vena cava occlusion, mesenteric venous thrombosis, upper extremity occlusion, acute cerebral vein thrombosis, and finally acute venous occlusion of hemodialysis access. In acute venous occlusion of the lower extremity phlebography is still the reference gold standard. Presently, duplex ultrasound with manual compression is the most sensitive and specific noninvasive test. Limitations of ultrasonography include isolated distal calf vein occlusion, obesity, and patients with lower extremity edema. If sonography is nondiagnostic, venography should be considered. Magnetic resonance venography can differentiate an acute occlusion from chronic thrombus, but because of its high cost and limited availability, it is not yet used for the routine diagnosis of lower extremity venous occlusion only. Regarding interventional treatment, catheter-directed thrombolysis can be applied to dissolve thrombus in charily selected patients with symptomatic occlusion and no contraindications to therapy. Acute occlusion of the pelvic veins and the inferior vena cava, often due to extension from the femoropopliteal system, represents a major risk for pulmonary embolism. Color flow Doppler imaging is often limited owing to obesity and bowel gas. Venography has long been considered the gold standard for identifying proximal venous occlusion. Both CT scanning and MR imaging, however, can even more accurately diagnose acute pelvis vein or inferior vena cava occlusion. MRI is

  9. Nontraumatic vascular emergencies: imaging and intervention in acute venous occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Haage, Patrick; Schmitz-Rode, Thomas [Department of Diagnostic Radiology, University of Technology Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Krings, Timo [Department of Neuroradiology, University of Technology Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany)

    2002-11-01

    Risk factors for acute venous occlusion range from prolonged immobilization to hypercoagulability syndromes, trauma, and malignancy. The aim of this review article is to illustrate the different imaging options for the diagnosis of acute venous occlusion and to assess the value of interventional strategies for venous thrombosis treatment in an emergency setting. First, diagnosis and treatment of the most common form of venous occlusion, at the level of the lower extremities, is presented, followed by pelvic vein and inferior vena cava occlusion, mesenteric venous thrombosis, upper extremity occlusion, acute cerebral vein thrombosis, and finally acute venous occlusion of hemodialysis access. In acute venous occlusion of the lower extremity phlebography is still the reference gold standard. Presently, duplex ultrasound with manual compression is the most sensitive and specific noninvasive test. Limitations of ultrasonography include isolated distal calf vein occlusion, obesity, and patients with lower extremity edema. If sonography is nondiagnostic, venography should be considered. Magnetic resonance venography can differentiate an acute occlusion from chronic thrombus, but because of its high cost and limited availability, it is not yet used for the routine diagnosis of lower extremity venous occlusion only. Regarding interventional treatment, catheter-directed thrombolysis can be applied to dissolve thrombus in charily selected patients with symptomatic occlusion and no contraindications to therapy. Acute occlusion of the pelvic veins and the inferior vena cava, often due to extension from the femoropopliteal system, represents a major risk for pulmonary embolism. Color flow Doppler imaging is often limited owing to obesity and bowel gas. Venography has long been considered the gold standard for identifying proximal venous occlusion. Both CT scanning and MR imaging, however, can even more accurately diagnose acute pelvis vein or inferior vena cava occlusion. MRI is

  10. Depicting Occlusion in Early Renaissance Art

    OpenAIRE

    Gillam, Barbara

    2011-01-01

    The artist attempting to give the impression of three-dimensional relationships must convey somehow that one surface is in front of another. There is a large and venerable literature in Psychology on this subject, showing how figure-ground, border ownership and amodal completion and continuation are determined but there is almost no discussion of how artist's have recruited these and other principles to create convincing impressions of occlusion. Even Gombrich (Art & Illusion 1960) only consi...

  11. Transient oxidation of Al-deposited Fe-Cr-Al alloy foil

    International Nuclear Information System (INIS)

    Andoh, A.

    1997-01-01

    The oxide phases formed on an Al-deposited Fe-Cr-Al alloy foil and an Fe-Cr-Al alloy foil of the same levels of Al and (La+Ce) contents, and their oxidation kinetics have been studied in air at 1173 and 1373 K using TGA, XRD and SEM. Al deposition promotes the growth of metastable aluminas (θ-Al 2 O 3 , γ-Al 2 O 3 ). Scales consisting of θ-Al 2 O 3 and a small amount of α-Al 2 O 3 develop on the Al-deposited foil at 1173 K and exhibit the whisker-type morphology. In the early stage of oxidation at 1373 K, thick scales consisting of θ-Al 2 O 3 and α-Al 2 O 3 grow rapidly on the Al-deposited foil. The transformation from θ-Al 2 O 3 to α-Al 2 O 3 is very fast, and the scales result in only α-Al 2 O 3 . In contrast, α-Al 2 O 3 scales containing a minor amount of FeAl 2 O 4 develop on the alloy foil. The growth rate of α-Al 2 O 3 scales on the Al-deposited foil is smaller than that on the alloy foil and very close to that on NiAl at 1373 K. (orig.)

  12. An Assessment of Gas Foil Bearing Scalability and the Potential Benefits to Civilian Turbofan Engines

    Science.gov (United States)

    Bruckner, Robert J.

    2010-01-01

    Over the past several years the term oil-free turbomachinery has been used to describe a rotor support system for high speed turbomachinery that does not require oil for lubrication, damping, or cooling. The foundation technology for oil-free turbomachinery is the compliant foil bearing. This technology can replace the conventional rolling element bearings found in current engines. Two major benefits are realized with this technology. The primary benefit is the elimination of the oil lubrication system, accessory gearbox, tower shaft, and one turbine frame. These components account for 8 to 13 percent of the turbofan engine weight. The second benefit that compliant foil bearings offer to turbofan engines is the capability to operate at higher rotational speeds and shaft diameters. While traditional rolling element bearings have diminished life, reliability, and load capacity with increasing speeds, the foil bearing has a load capacity proportional to speed. The traditional applications for foil bearings have been in small, lightweight machines. However, recent advancements in the design and manufacturing of foil bearings have increased their potential size. An analysis, grounded in experimentally proven operation, is performed to assess the scalability of the modern foil bearing. This analysis was coupled to the requirements of civilian turbofan engines. The application of the foil bearing to larger, high bypass ratio engines nominally at the 120 kN (approx.25000 lb) thrust class has been examined. The application of this advanced technology to this system was found to reduce mission fuel burn by 3.05 percent.

  13. Clinical study of internal carotid artery occlusion

    International Nuclear Information System (INIS)

    Okada, Kyoko

    1989-01-01

    Fourteen patients with internal carotid artery (ICA) occlusion identified by cerebral angiography were studied for clinical features, computed tomographic findings, collateral circulation and risk factors. Eleven patients were males, and at age distribution it occurred more frequently in patients over 50 years to 60 years of age rather than other ages. As for the risk factors of cerebral infarction, smoking was more frequent in patients with thrombosis, and heart disease was more common in those with embolism. Stroke occurred progressively in patients with thrombosis whereas it occurred suddenly in those with embolism. The consciousness was more severely disturbed in patients with embolism than in those with thrombosis. On neuro-radiological findings, in the patients with thrombosis, the infarcted area on CT were small and emerged as deep or watershed types, and on the angiograms, occlusion at carotid bifurcation were found more frequently and the collateral circulation were well developed. In those with embolism, the infarcted areas were large and emerged as cortical types, and on the angiograms, occlusions were observed more frequently in the intracranial portion and collateral circulation were poorly developed. In many patients with thrombosis, platelet aggregation, hematocrit and blood viscosity increased, but in those with embolism did not. (author)

  14. Poster - Thur Eve - 27: Scattering foil redesign for modulated electron radiotherapy.

    Science.gov (United States)

    Connell, T; Seuntjens, J

    2012-07-01

    This work serves to build on existing work that discussed the advantages of removing the scattering foil from the beamline for modulated electron radiotherapy (MERT) much like flattening filter-free beams in photon IMRT. Due to concerns about the ability of the accelerators transmission ionization chamber to function normally with narrow, minimally-scattered beams as well as a limited maximum field size, this study focused on the design of a new custom scattering foil that was optimized for MERT applications. Different foil parameters such as material, thickness and shape were investigated to produce a minimally scattered beam, as opposed to a flat beam in the case of the clinical foil, while preserving the dosimetric benefits of a reduced thickness foil such as dramatically higher dose rate and reduced photon contamination in the bremsstrahlung tail. Using a Monte Carlo model that was verified against measured data, fluence profiles at the level of the transmission ionization chamber were produced and analyzed for all foil configurations, as well as PDDs and profiles in a water phantom. It was found that a simple foil of slab geometry made of low to medium Z material with the thickness determined by the maximum desirable field size and chosen electron energy produced a sufficiently scattered beam that maintained the dosimetric advantages of a scattering-foil-free beamline. These new foils, when applied to MERT, have the advantage of reducing treatment time due to higher dose rates and reducing dose to healthy tissue due to reduced dose in the bremsstrahlung tail. © 2012 American Association of Physicists in Medicine.

  15. Reconstruction of the nasal septum using perforated and unperforated polydioxanone foil.

    Science.gov (United States)

    Tweedie, Daniel J; Lo, Stephen; Rowe-Jones, Julian M

    2010-01-01

    To present our experience of reconstruction of the nasal septum using perforated and unperforated foils, particularly with respect to functional and aesthetic sequelae. A retrospective medical record review of a prospectively conducted case series was undertaken of all consecutive patients who underwent septal reconstruction using polydioxanone foil in a 4-year period. Procedures included septorhinoplasty and isolated septoplasty via external and endonasal approaches using corporeal and extracorporeal techniques. The polydioxanone foils were in battens or sheets. Fifty patients underwent septal reconstruction using unperforated (first 26 patients) or perforated (next 24 patients) polydioxanone foil. Median total postoperative follow-up was 51.5 months (range, 34-60 months) for unperforated foil and 20.5 months (range, 12-31 months) for perforated foil. All the patients were reviewed for assessment of appearance and function. Forty-three patients had satisfactory results, needing no further treatment. Three patients required minor septal or tip revision surgery. Four patients experienced moderate saddling of the dorsum (all involved unperforated polydioxanone foil) and underwent successful revision surgery using auricular cartilage grafts. Synthetic materials are a useful alternative to autologous tissues during reconstruction of the nasal septum. To our knowledge, we present the largest single-center series of septal reconstructions using unperforated and perforated polydioxanone foils-shown to be useful in the correction of complex septal deformity. However, the unperforated form seems to be associated with a significant risk of postoperative saddling, and we warn against its use in this context. No such complications were observed with the use of thin, 0.15-mm perforated polydioxanone foil, which we exclusively recommend for this application. The use of this implant warrants further evaluation.

  16. Goal-directed mechanisms that constrain retrieval predict subsequent memory for new "foil" information.

    Science.gov (United States)

    Vogelsang, David A; Bonnici, Heidi M; Bergström, Zara M; Ranganath, Charan; Simons, Jon S

    2016-08-01

    To remember a previous event, it is often helpful to use goal-directed control processes to constrain what comes to mind during retrieval. Behavioral studies have demonstrated that incidental learning of new "foil" words in a recognition test is superior if the participant is trying to remember studied items that were semantically encoded compared to items that were non-semantically encoded. Here, we applied subsequent memory analysis to fMRI data to understand the neural mechanisms underlying the "foil effect". Participants encoded information during deep semantic and shallow non-semantic tasks and were tested in a subsequent blocked memory task to examine how orienting retrieval towards different types of information influences the incidental encoding of new words presented as foils during the memory test phase. To assess memory for foils, participants performed a further surprise old/new recognition test involving foil words that were encountered during the previous memory test blocks as well as completely new words. Subsequent memory effects, distinguishing successful versus unsuccessful incidental encoding of foils, were observed in regions that included the left inferior frontal gyrus and posterior parietal cortex. The left inferior frontal gyrus exhibited disproportionately larger subsequent memory effects for semantic than non-semantic foils, and significant overlap in activity during semantic, but not non-semantic, initial encoding and foil encoding. The results suggest that orienting retrieval towards different types of foils involves re-implementing the neurocognitive processes that were involved during initial encoding. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Performance variation due to stiffness in a tuna-inspired flexible foil model.

    Science.gov (United States)

    Rosic, Mariel-Luisa N; Thornycroft, Patrick J M; Feilich, Kara L; Lucas, Kelsey N; Lauder, George V

    2017-01-17

    Tuna are fast, economical swimmers in part due to their stiff, high aspect ratio caudal fins and streamlined bodies. Previous studies using passive caudal fin models have suggested that while high aspect ratio tail shapes such as a tuna's generally perform well, tail performance cannot be determined from shape alone. In this study, we analyzed the swimming performance of tuna-tail-shaped hydrofoils of a wide range of stiffnesses, heave amplitudes, and frequencies to determine how stiffness and kinematics affect multiple swimming performance parameters for a single foil shape. We then compared the foil models' kinematics with published data from a live swimming tuna to determine how well the hydrofoil models could mimic fish kinematics. Foil kinematics over a wide range of motion programs generally showed a minimum lateral displacement at the narrowest part of the foil, and, immediately anterior to that, a local area of large lateral body displacement. These two kinematic patterns may enhance thrust in foils of intermediate stiffness. Stiffness and kinematics exhibited subtle interacting effects on hydrodynamic efficiency, with no one stiffness maximizing both thrust and efficiency. Foils of intermediate stiffnesses typically had the greatest coefficients of thrust at the highest heave amplitudes and frequencies. The comparison of foil kinematics with tuna kinematics showed that tuna motion is better approximated by a zero angle of attack foil motion program than by programs that do not incorporate pitch. These results indicate that open questions in biomechanics may be well served by foil models, given appropriate choice of model characteristics and control programs. Accurate replication of biological movements will require refinement of motion control programs and physical models, including the creation of models of variable stiffness.

  18. X-ray measurements of total reflectivity and scattering from Au-coated foils

    DEFF Research Database (Denmark)

    Hornstrup, Allan; Christensen, Finn Erland; Jespersen, Ellen

    1990-01-01

    We present x-ray measurements of total reflectivity and scattering from gold-coated foils. The foils are two sorts of 0.3 mm thick dip-lacquered aluminum, 0.125 mm thick plastic (Upilex) and 0.5 mm thick dip-lacquered nickel. The analysis of the data shows a high reflectivity for all...... but the plastic foil, and only small microroughness (∼15 Å at length scales below ∼0.1 μm), evidenced by low resolution scattering measurements....

  19. Elevated-Temperature Tensile-Testing of Foil-Gage Metals

    Science.gov (United States)

    Blackburn, L. B.; Ellingsworth, J. R.

    1986-01-01

    Automated system for measuring strain in metal foils at temperatures above 500 degrees F (260 degrees C) uses mechanical extensometer and displacement transducer. System includes counterbalance feature, which eliminates weight contribution of extensometer and reduces grip pressure required for attachment to specimen. Counterbalancing feature overcomes two major difficulties in using extensometers with foil-gage specimens: (1) Weight of extensometer and transducer represents significant fraction of total load applied to specimen and may actually damage it; and (2) grip pressure required for attachment of extensometer to specimens may induce bending stresses in foil-gage materials.

  20. Electroplating fission-recoil barriers onto LEU-metal foils for 99Mo-production targets

    International Nuclear Information System (INIS)

    Smaga, J.A.; Sedlet, J.; Conner, C.; Liberatore, M.W.; Walker, D.E.; Wygmans, D.G.; Vandegrift, G.F.

    1997-01-01

    Electroplating experiments on uranium foil have been conducted in order to develop low-enriched uranium composite targets suitable for the production of 99 Mo. Preparation of the foil surface prior to plating was found to play a key role in the quality of the resultant coating. A surface preparation procedure was developed that produces both zinc and nickel coatings with the desired level of coating adherence and coverage. Modifications of the existing plating processes now need investigation to improve to uniformity of the plating thickness, especially at the foil perimeter. (author)

  1. Electroplating fission-recoil barriers onto LEU-metal foils for 99Mo-production targets

    International Nuclear Information System (INIS)

    Smaga, J.A.; Sedlet, J.; Conner, C.; Liberatore, M.W.; Walker, D.E.; Wygmans, D.G.; Vandegrift, G.F.

    1997-10-01

    Electroplating experiments on uranium foil have been conducted in order to develop low-enriched uranium composite targets suitable for the production of 99 Mo. Preparation of the foil surface prior to plating was found to play a key role in the quality of the resultant coating. A surface preparation procedure was developed that produces both zinc and nickel coatings with the desired level of coating adherence and coverage. Modifications of the existing plating processes now need investigation to improve to uniformity of the plating thickness, especially at the foil perimeter

  2. Measurement of the thickness and homogeneity of thin foils by slowing down alpha particles

    International Nuclear Information System (INIS)

    Bimbot, R.; Della Negra, S.; Deprun, C.; Gardes, D.; Rivet, M.F.

    1979-01-01

    The energy loss of 8.785 MeV α particles passing through a thin foil is used to measure the foil thickness. The measurement is performed in various points of the target, the abscissa and ordinate of which are set with precision from the outside of the chamber. This gives a thickness map of the target. The working up of the data, and the use of energy loss tables are made in a standard way. The absolute uncertainty is of some percent for 100 μg/cm 2 foils. The technique has been refined to reach the same precision for 10 μg/cm 2 targets [fr

  3. Postural stability and occlusal status among Japanese elderly.

    Science.gov (United States)

    Song-Yu, Xuan; Rodis, Omar M M; Ogata, Sagiri; Can-Hu, Jin; Nishimura, Michiko; Matsumura, Seishi

    2012-06-01

    There are still no data available on the relationship between postural stability and occlusal status among the elderly. To examine relationships between postural stability and occlusal status through a cohort study among elderly Japanese. Oral examination, occlusal status, postural stability and a questionnaire were conducted and given to 87 community-dwelling Japanese at enrolment. The average occlusal pressure of the female group was statistically higher than the male group while average occlusal pressure and postural stability length were lesser in the group with more remaining teeth. Postural stability area and number of remaining teeth showed statistically significant correlations. Postural stability length was lesser in the group with strong occlusal force. Furthermore, the number of decayed teeth was fewer in the good hygiene group. This study identified a close relationship between occlusal status and postural stability of Japanese older individuals. Occlusal hypofunction was observed more in those with occlusal problems, and a decrease in their occlusal functions resulted in postural instability. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  4. A study on occlusal stability in shortened dental arches.

    Science.gov (United States)

    Sarita, Paulo T N; Kreulen, Cees M; Witter, Dick J; van't Hof, Martin; Creugers, Nico H J

    2003-01-01

    The aim of this study was to verify the hypothesis that shortened dental arches constitute a risk to occlusal stability. Using cluster samples, 725 subjects with shortened dental arches comprising intact anterior regions and zero to eight occluding pairs of posterior teeth and 125 subjects with complete dental arches were selected. Subjects with shortened dental arches were classified into eight categories according to arch length and symmetry. Parameters for occlusal stability were interdental spacing, occlusal tooth wear, occlusal contact of incisors in intercuspal position, and vertical and horizontal overlap. Additionally, tooth mobility and overeruption of unopposed teeth were assessed. Influence of independent variables (dental arch category, age, gender, and residence) on the parameters for occlusal stability was assessed by one-way ANOVA and Tukey's multiple range tests. Extreme shortened dental arches (zero to two pairs of occluding premolars) had significantly more interdental spacing, occlusal contact of incisors, and vertical overlap compared to complete dental arches. Occlusal wear and prevalence of mobile teeth were highest in these categories. The category with three to four occluding premolars had significantly more interdental spacing and, for the older age group, more anterior teeth in occlusal contact compared to complete dental arches. Age was consistently associated with increased changes in occlusal integrity. Signs of increased risk to occlusal stability seemed to occur in extreme shortened dental arches, whereas no such evidence was found for intermediate categories of shortened dental arches.

  5. Structured sparse error coding for face recognition with occlusion.

    Science.gov (United States)

    Li, Xiao-Xin; Dai, Dao-Qing; Zhang, Xiao-Fei; Ren, Chuan-Xian

    2013-05-01

    Face recognition with occlusion is common in the real world. Inspired by the works of structured sparse representation, we try to explore the structure of the error incurred by occlusion from two aspects: the error morphology and the error distribution. Since human beings recognize the occlusion mainly according to its region shape or profile without knowing accurately what the occlusion is, we argue that the shape of the occlusion is also an important feature. We propose a morphological graph model to describe the morphological structure of the error. Due to the uncertainty of the occlusion, the distribution of the error incurred by occlusion is also uncertain. However, we observe that the unoccluded part and the occluded part of the error measured by the correntropy induced metric follow the exponential distribution, respectively. Incorporating the two aspects of the error structure, we propose the structured sparse error coding for face recognition with occlusion. Our extensive experiments demonstrate that the proposed method is more stable and has higher breakdown point in dealing with the occlusion problems in face recognition as compared to the related state-of-the-art methods, especially for the extreme situation, such as the high level occlusion and the low feature dimension.

  6. [The impact of occlusal plane orientation method on intercuspal occlusion estimation].

    Science.gov (United States)

    Zhulev, E N; Bogatova, E A; Ershov, P E; Lepakhina, A A

    2013-01-01

    The study was conducted on 50 students with orthognatic bite aged from 17 to 23 years. After taking impressions of the upper and lower dental arches and making cast models these were fixed in articulator Inter-frame space in four ways: by means of facial arch oriented on Camper plane or Frankfurt horizontal, with the help of standard semianatomical table or HIP-analyzer and a table for fixing the HIP-plane. Occlusal contacts were checked with occlusion paper (200 microns, Bausch) in the central, lateral and anterior occlusion and then analyzed using Adobe Photoshop and Universal Desktop Ruler. The most precise results were seen in cases casted by means of HIP-analyzer.

  7. Application of photogrammetry for analysis of occlusal contacts.

    Science.gov (United States)

    Shigeta, Yuko; Hirabayashi, Rio; Ikawa, Tomoko; Kihara, Takuya; Ando, Eriko; Hirai, Shinya; Fukushima, Shunji; Ogawa, Takumi

    2013-04-01

    The conventional 2D-analysis methods for occlusal contacts provided limited information on tooth morphology. This present study aims to detect 3D positional information of occlusal contacts from 2D-photos via photogrammetry. We propose an image processing solution for analysis of occlusal contacts and facets via the black silicone method and a photogrammetric technique. The occlusal facets were reconstructed from a 2D-photograph data-set of inter-occlusal records into a 3D image via photogrammetry. The configuration of the occlusal surface was reproduced with polygons. In addition, the textures of the occlusal contacts were mapped to each polygon. DIFFERENCE FROM CONVENTIONAL METHODS: Constructing occlusal facets with 3D polygons from 2D-photos with photogrammetry was a defining characteristic of this image processing technique. It allowed us to better observe findings of the black silicone method. Compared with conventional 3D analysis using a 3D scanner, our 3D models did not reproduce the detail of the anatomical configuration. However, by merging the findings of the inter-occlusal record, the deformation of mandible and the displacement of periodontal ligaments under occlusal force were reflected in our model. EFFECT OR PERFORMANCE: Through the use of polygons in the conversion of 2D images to 3D images, we were able to define the relation between the location and direction of the occlusal contacts and facets, which was difficult to detect via conventional methods. Through our method of making a 3D polygon model, the findings of inter-occlusal records which reflected the jaw/teeth behavior under occlusal force could be observed 3-dimensionally. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. A new method of evaluating posterior occlusion and its relation to posttreatment occlusal changes.

    Science.gov (United States)

    Parkinson, C E; Buschang, P H; Behrents, R G; Throckmorton, G S; English, J D

    2001-11-01

    The purpose of this study was to assess the relationship between posterior occlusion and posttreatment changes in other occlusal variables. Pretreatment (T1), posttreatment (T2), and postretention (T3) records were obtained for 49 Class I (n = 23) and Class II (n = 26) extraction cases. Overbite, overjet, mandibular incisor irregularity, right and left molar deviations, midline deviation, and mandibular arch length were measured, and occlusal registrations were made of each set of dental casts. The proximity of posterior occlusal surfaces was measured as the contact or near-contact areas at or below 300 microm thickness, based on the optical densities of scanned images of the posterior occlusal registrations. The treatment changes for overbite, overjet, right and left molar deviation, and arch length were significantly greater in the Class II group, and the reductions in incisor irregularity were greater in the Class I group. No other class differences were found. Overbite, overjet, and incisor irregularity increased after treatment, and arch length continued to decrease, with no significant class differences. Contact and near-contact areas at or below 300 microm constituted 7% of the functional occlusal table for both classes at the end of treatment, having decreased significantly in both groups (21% in Class I and 29% in Class II) during treatment. Because contact and near-contact areas increased in some patients and decreased in others, there were no significant posttreatment changes. Negative correlations were found between contact and near-contact areas at T2 and changes in overjet from T2 to T3, and between contact and near-contact areas at T3 and changes in overbite from T2 to T3. No relationships were found between posterior contact and near-contact area and incisor irregularity. We concluded that (1) the area of actual and near contacts at or below 300 microm decreased significantly with treatment, indicating that, despite excellent treatment results by

  9. Electronic state alignment, orientation, and coherence produced by beam-foil collisions

    International Nuclear Information System (INIS)

    Church, D.A.

    1975-01-01

    The cylindrically symmetric beam-foil collision produces excitation and alignment of atom and ion levels similar, but not identical, to that resulting at comparable energies from ion-atom or ion-molecule collisions. When the foil is tilted, the macroscopic change acts on the microscopic scale to produce coherent alignment and orientation of the excited levels. The maximum beam energy range bounding this interaction has not yet been defined. The dynamic interaction which produces these effects is currently not predicted by any theory, although the dynamics of the ions subsequent to the collision are well understood. Refinement of current experimental technique can be expected to better define the final foil surface. The beam-tilted-foil collision promises to be useful in the study of ionic structure via quantum beat, radio-frequency and level-crossing spectroscopy techniques, and may provide a useful probe for certain surface interactions. 4 figs, 48 refs

  10. One-step synthesis of TiO₂ nanorod arrays on Ti foil for supercapacitor application.

    Science.gov (United States)

    Zheng, Zhi; Chen, Jiajun; Yoshida, Ryuji; Gao, Xiang; Tarr, Kayla; Ikuhara, Yumi H; Zhou, Weilie

    2014-10-31

    Titanium dioxide (TiO2) nanorod arrays grown directly on Ti metal foil were prepared by a facile one-step hydrothermal method, in which the Ti foil serves as both substrate and precursor. The nanorods are tetragonal rutile single crystal with growth orientation along the [001] direction. The electrochemical properties of the TiO2 nanorod arrays were systematically investigated by cyclic voltammetry, galvanostatic charge/discharge and electrochemical impedance spectroscopy using a three-electrode system. As a result, the TiO2 nanorod arrays exhibit good areal specific capacitance and excellent cyclic stability by retaining more than 98% of the initial specific capacitance after 1000 cycles. In addition, a good flexibility of the Ti foil with TiO2 nanorod arrays was demonstrated by the stable electrochemical performance under different bending angles, which indicates that TiO2 nanorod arrays grown on Ti foil could be a promising electrode material for flexible supercapacitor application.

  11. Modeling the mechanical deformation of nickel foils for nanoimprint lithography on double-curved surfaces

    DEFF Research Database (Denmark)

    Sonne, Mads Rostgaard; Cech, Jiri; Hattel, Jesper Henri

    2013-01-01

    on an aluminium substrate with three different radii; 500 μm, 1000 μm and 2000 μm, respectively. The nano imprint is performed using a 50 μm thick nickel foil, manufactured using electroforming. During the imprinting process, the nickel foil is stretched due to the curved surface of the aluminium substrate....... Experimentally, it is possible to address this stretch by counting the periods of the cross-gratings via SEM characterization. A model for the deformation of the nickel foil during nanoimprint is developed, utilizing non-linear material and geometrical behaviour. Good agreement between measured and numerically...... calculated stretch ratios on the surface of the deformed nickel foil is found, and it is shown, that from the model it is also possible to predict the geometrical extend of the nano-structured area on the curved surfaces....

  12. Self-propelled swimming of a flexible plunging foil near a solid wall.

    Science.gov (United States)

    Dai, Longzhen; He, Guowei; Zhang, Xing

    2016-07-05

    Numerical simulations are conducted to investigate the influences of a solid wall on the self-propelled swimming of a flexible plunging foil. It is found that the presence of a solid wall enhances the cruising speed, with the cost of increasing input power. Rigid foil can achieve high percentage increase in cruising speed when swimming near a solid wall, but the propulsive efficiency may be reduced. Foils with some flexibility can enjoy the enhancements in both cruising speed and propulsive efficiency. Another advantage of the flexible foils in near-wall swimming is that smaller averaged lateral forces are produced. The effects of wall confinement on the wake structure and the vortex dynamics are also studied in this paper. The results obtained in this study shed some light on the unsteady wall effect experienced by aquatic animals and also inform the design of bio-mimetic underwater vehicles which are capable of exploiting the wall effect.

  13. A free-standing thin foil bolometer for measuring soft x-ray fluence.

    Science.gov (United States)

    Hu, Qingyuan; Ning, Jiamin; Ye, Fan; Meng, Shijian; Xu, Rongkun; Yang, Jianlun; Chu, Yanyun; Qin, Yi; Fu, Yuecheng; Chen, Faxin; Xu, Zeping

    2016-10-01

    A free-standing thin foil bolometer for measuring soft x-ray fluence in z-pinch experiments is developed. For the first time, we present the determination of its sensitivity by different methods. The results showed great consistency for the different methods, which confirms the validity of the sensitivity and provides confidence for its application in z-pinch experiments. It should be highlighted that the sensitivity of a free-standing foil bolometer could be calibrated directly using Joule heating without any corrections that will be necessary for a foil bolometer with substrate because of heat loss. The difference of the waveforms between the free-standing foil bolometer and that with substrate is obvious. It reveals that the heat loss to the substrate should be considered for the latter in despite of the short x-ray pulse when the peak value is used to deduce the total deposited energy. The quantitative influence is analyzed through a detailed simulation.

  14. Use of Soller slits to remove reference foil fluorescence from transmission spectra.

    Science.gov (United States)

    Tse, Justin J; George, Graham N; Pickering, Ingrid J

    2011-05-01

    Measurement of X-ray absorption spectroscopy (XAS) in transmission is the method of choice for strong or concentrated samples. In a typical XAS experiment above 5 keV the sample is placed between the first (I(0)) and second (I(1)) ion chambers and a standard foil is placed between the second (I(1)) and third (I(2)) ion chambers for simultaneous calibration of energy during sample analysis. However, some fluorescence from the foil may be registered in I(1), causing anomalies in the transmission signal of the sample, especially when the sample edge jump is relatively small. To remedy this, Soller slits were constructed and placed between the foil and I(1) to minimize back-fluorescence from the foil. A comparison of blank and standard samples, measured with or without Soller slits or under a worst-case scenario, demonstrates the advantages of Soller slits when analyzing weak signal samples via transmission XAS.

  15. Ultrathin foils used for low-energy neutral atom imaging of the terrestrial magnetosphere

    International Nuclear Information System (INIS)

    Funsten, H.O.; McComas, D.J.; Barraclough, B.L.

    1993-01-01

    Magnetospheric imaging by remote detection of low-energy neutral atoms (LENAs) that are created by charge exchange between magnetospheric plasma ions and neutral geocoronal atoms has been proposed as a method to provide global information of magnetospheric dynamics. For LENA detecting, carbon foils can be implemented to (1) ionize the LENAs and electrostatically remove them from the large background of solar UV scattered by the geocorona to which LENA detectors (e.g., microchannel plates) are sensitive and (2) generate secondary electrons to provide coincidence and/or LENA trajectory information. Quantification of LENA-foil interactions are crucial in defining LENA imager performance. The authors present equilibrium charge state distributions due to foil contamination from exposure to air. Angular scattering that results from the projectile-foil interaction is quantified and is shown to be independent of the charge state distribution

  16. Foil Gas Bearing Supported Quiet Fan for Spacecraft Ventilation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Developing a quiet fan for Environmental Control and Life Support systems to enhance the livable environment within the spacecraft has been a challenge. A Foil Gas...

  17. Laser ultrasonic inspection of the microstructural state of thin metal foils.

    Science.gov (United States)

    Balogun, O; Huber, R; Chinn, D; Spicer, J B

    2009-03-01

    A laser-based ultrasonic technique suitable for characterization of the microstructural state of metal foils is presented. The technique relies on the measurement of the intrinsic attenuation of laser-generated longitudinal waves at frequencies reaching 1 GHz resulting from ultrasonic interaction with the sample microstructure. In order to facilitate accurate measurement of the attenuation, a theoretical model-based signal analysis approach is used. The signal analysis approach isolates aspects of the measured attenuation that depend strictly on the microstructure from geometrical effects. Experimental results obtained in commercially cold worked tungsten foils show excellent agreement with theoretical predictions. Furthermore, the experimental results show that the longitudinal wave attenuation at gigahertz frequencies is strongly influenced by the dislocation content of the foils and may find potential application in the characterization of the microstructure of micron thick metal foils.

  18. Effect of liquid uranium on tungsten foils up to 1350/sup 0/C

    Energy Technology Data Exchange (ETDEWEB)

    Kuznietz, M.; Livne, Z.; Cotler, C.; Erez, G.

    1988-11-01

    Immersion experiments have been performed to investigate the effect of liquid uranium on 0.3-mm-thick foils of tungsten metal in the temperature range of 1160 to 1350/sup 0/C, for immersion times up to 20 h, in zirconia crucibles. The original and uranium-reacted foils have been studied microscopically (SEM-EDAX) and the internal morphology has been determined. The latter is affected by the heat-treatment and penetration of liquid uranium. The penetration is partial up to 1210/sup 0/C, accompanied by a partial uranium-assisted recrystallization, forming two metallurgically-different regions, which on cooling result in the observed cracks due to inhomogeneous strain. The penetration of liquid uranium is complete at 1255/sup 0/C and above, inducing recrystallization of tungsten grains throughout the foil, with larger, uranium-lined, grains in inner regions, and smaller, progressively-separated, tungsten grains in outer regions (with reduction in foil thickness).

  19. Progressive dissolution of molybdenum foils in liquid uranium at 1160/sup 0/C

    Energy Technology Data Exchange (ETDEWEB)

    Kuznietz, M.; Cotler, C.

    1988-12-01

    Immersion experiments have been performed to investigate the progressive dissolution of 0.3-mm-thick foils of molybdenum metal in liquid uranium at 1160/sup 0/C, for immersion times of 3, 6, 10, and 60 min, and 20 h, in a zirconia crucible. The original foils, as-received and heat-treated at 1160/sup 0/C, and the uranium-reacted foils have been studied microscopically (SEM-EDAX) and the internal morphology has been determined. The flow lines in as-received molybdenum disappear under heat-treatment, while the undistinguishable grains recrystallize upon heating into grains with average size of 20 m, persisting in samples immersed in liquid uranium. The recrystallization is not uranium-assisted, as uranium does not penetrate into intergranular regions. After incubation time of 3-4 min, outer molybdenum grains dissolve in liquid uranium, thereby reducing the foil thickness progressively. Full dissolution occurs for about 15-min immersion.

  20. An Experimental Investigation into the Temperature Profile of a Compliant Foil Air Bearing

    National Research Council Canada - National Science Library

    Radil, Kevin

    2004-01-01

    A series of tests was performed to determine the internal temperature profile in a compliant bump-type foil journal air bearing operating at room temperature under various speeds and load conditions...

  1. Note: Radial-thrust combo metal mesh foil bearing for microturbomachinery.

    Science.gov (United States)

    Park, Cheol Hoon; Choi, Sang Kyu; Hong, Doo Euy; Yoon, Tae Gwang; Lee, Sung Hwi

    2013-10-01

    This Note proposes a novel radial-thrust combo metal mesh foil bearing (MMFB). Although MMFBs have advantages such as higher stiffness and damping over conventional air foil bearings, studies related to MMFBs have been limited to radial MMFBs. The novel combo MMFB is composed of a radial top foil, thrust top foils, and a ring-shaped metal mesh damper--fabricated by compressing a copper wire mesh--with metal mesh thrust pads for the thrust bearing at both side faces. In this study, the combo MMFB was fabricated in half-split type to support the rotor for a micro gas turbine generator. The manufacture and assembly process for the half-split-type combo MMFB is presented. In addition, to verify the proposed combo MMFB, motoring test results up to 250,000 rpm and axial displacements as a function of rotational speed are presented.

  2. Process for forming a nickel foil with controlled and predetermined permeability to hydrogen

    Science.gov (United States)

    Engelhaupt, Darell E.

    1981-09-22

    The present invention provides a novel process for forming a nickel foil having a controlled and predetermined hydrogen permeability. This process includes the steps of passing a nickel plating bath through a suitable cation exchange resin to provide a purified nickel plating bath free of copper and gold cations, immersing a nickel anode and a suitable cathode in the purified nickel plating bath containing a selected concentration of an organic sulfonic acid such as a napthalene-trisulfonic acid, electrodepositing a nickel layer having the thickness of a foil onto the cathode, and separating the nickel layer from the cathode to provide a nickel foil. The anode is a readily-corrodible nickel anode. The present invention also provides a novel nickel foil having a greater hydrogen permeability than palladium at room temperature.

  3. Process for forming a nickel foil with controlled and predetermined permeability to hydrogen

    International Nuclear Information System (INIS)

    Engelhaupt, D. E.

    1981-01-01

    The present invention provides a novel process for forming a nickel foil having a controlled and predetermined hydrogen permeability. This process includes the steps of passing a nickel plating bath through a suitable cation exchange resin to provide a purified nickel plating bath free of copper and gold cations, immersing a nickel anode and a suitable cathode in the purified nickel plating bath containing a selected concentration of an organic sulfonic acid such as a napthalene-trisulfonic acid, electrodepositing a nickel layer having the thickness of a foil onto the cathode, and separating the nickel layer from the cathode to provide a nickel foil. The anode is a readilycorrodible nickel anode. The present invention also provides a novel nickel foil having a greater hydrogen permeability than palladium at room temperature

  4. LANL Experience Rolling Zr-Clad LEU-10Mo Foils for AFIP-7

    Energy Technology Data Exchange (ETDEWEB)

    Hammon, Duncan L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Clarke, Kester D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Alexander, David J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kennedy, Patrick K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Edwards, Randall L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Duffield, Andrew N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dombrowski, David E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-05-29

    The cleaning, canning, rolling and final trimming of Low Enriched Uranium-10 wt. pct. Molybdenum (LEU-10Mo) foils for ATR (Advanced Test Reactor) fuel plates to be used in the AFIP-7 (ATR Full Size Plate In Center Flux Trap Position) experiments are summarized. Six Zr-clad foils were produced from two LEU-10Mo castings supplied to Los Alamos National Laboratory (LANL) by Y-12 National Security Complex. Details of cleaning and canning procedures are provided. Hot- and cold-rolling results are presented, including rolling schedules, images of foils in-process, metallography and local compositions of regions of interest, and details of final foil dimensions and process yield. This report was compiled from the slides for the presentation of the same name given by Duncan Hammon on May 12, 2011 at the AFIP-7 Lessons Learned meeting in Salt Lake City, UT, with Los Alamos National Laboratory document number LA-UR 11-02898.

  5. Magnetic collimation and metal foil filtering for electron range and fluence modulation

    International Nuclear Information System (INIS)

    Phaisangittisakul, N.; D'Souza, W.D.; Ma Lijun

    2004-01-01

    We investigated the use of magnetically collimated electron beams together with metal filters for electron fluence and range modulation. A longitudinal magnetic field collimation method was developed to reduce skin dose and to improve the electron beam penumbra. Thin metal foils were used to adjust the energies of magnetically collimated electrons. The effects for different types of foils such as Al, Be, Cu, Pb, and Ti were studied using Monte Carlo calculations. An empirical pencil beam dose calculation model was developed to calculate electron dose distributions under magnetic collimation and foil modulation. An optimization method was developed to produce conformal dose distributions for simulated targets such as a horseshoe-shaped target. Our results show that it is possible to produce an electron depth dose enhancement peak using similar techniques of producing a spread-out Bragg peak. In conclusion, our study demonstrates new aspects of using magnetic collimation and foil filtration for producing fluence and range modulated electron dose distributions

  6. Intense heavy ion beam-induced temperature effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    Kupka, K.; Tomut, M.; Simon, P.; Hubert, C.; Romanenko, A.; Lommel, B.; Trautmann, C.

    2015-01-01

    At the future FAIR facility, reliably working solid carbon stripper foils are desired for providing intermediate charge states to SIS18. With the expected high beam intensities, the foils experience enhanced degradation and limited lifetime due to severe radiation damage, stress waves, and thermal effects. This work presents systematic measurements of the temperature of different carbon-based stripper foils (amorphous, diamond-like, and carbon-nanotube based) exposed to 4.8 MeV/u U, Bi, and Au beams of different pulse intensities. Thermal and spectroscopic analyses were performed by means of infrared thermography and Fourier transform infrared spectroscopy. The resulting temperature depends on the foil thickness and strongly increases with increasing pulse intensity and repetition rate. (author)

  7. A change in humidification system can eliminate endotracheal tube occlusion.

    Science.gov (United States)

    Doyle, Alex; Joshi, Manasi; Frank, Peter; Craven, Thomas; Moondi, Parvez; Young, Peter

    2011-12-01

    Inadequate airway humidification can result in endotracheal tube occlusion. There is evidence that heat and moisture exchangers (HMEs) are more prone to endotracheal tube occlusion than heated humidifiers (HHs) that contain a heated wire circuit. We aimed to compare the incidence of endotracheal tube occlusion while introducing a new dual-heated wire circuit HH in place of an established hydrophobic HME. This was a prospective observational study. All patients who required intubation were included in our analysis. Univariate statistical analysis was performed using a Fisher exact test. P humidification exclusively by HH. In the subsequent 18-month period, there were no further episodes of endotracheal tube occlusion. Our study demonstrates that there is a significant increase in the incidence of endotracheal tube occlusion when using a hydrophobic HME compared with an HH and that using a dual-heated wire circuit HH can eliminate endotracheal tube occlusion. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Occlusion and periodontal disease--where is the link?

    Science.gov (United States)

    Fu, Jia Hui; Yap, Adrian U J

    2007-12-01

    The effect of occlusion on the periodontium has been the subject of much debate. Interest on this subject has decreased over the years but has been renewed with the popularity of implant dentistry. This paper reviews the literature and explores the relationship between trauma from occlusion with periodontal disease and peri-implant bone loss. With regards to periodontal disease, there are two schools of thought on the effect that trauma from occlusion has on the periodontium. One believes that trauma from occlusion is a co-destructive factor in the initiation and progression of periodontal disease. The other believes that it is not. Up till now, there are no conclusive explanations on the association between trauma from occlusion and periodontal disease. For dental implants, current literature suggests that there is an association between occlusal overloading and peri-implant bone loss even in the absence of inflammation. However, there is a need for more randomized clinical trials to validate this relationship.

  9. Method to Increase Performance of Foil Bearings Through Passive Thermal Management

    Science.gov (United States)

    Bruckner, Robert

    2013-01-01

    This invention is a new approach to designing foil bearings to increase their load capacity and improve their reliability through passive thermal management. In the present case, the bearing is designed in such a way as to prevent the carryover of lubricant from the exit of one sector to the inlet of the ensuing sector of the foil bearing. When such passive thermal management techniques are used, bearing load capacity is improved by multiples, and reliability is enhanced when compared to current foil bearings. This concept has recently been tested and validated, and shows that load capacity performance of foil bearings can be improved by a factor of two at relatively low speeds with potentially greater relative improvements at higher speeds. Such improvements in performance with respect to speed are typical of foil bearings. Additionally, operation of these newly conceived bearings shows much more reliability and repeatable performance. This trait can be exploited in machine design to enhance safety, reliability, and overall performance. Finally, lower frictional torque has been demonstrated when operating at lower (non-load capacity) loads, thus providing another improvement above the current state of the art. The objective of the invention is to incorporate features into a foil bearing that both enhance passive thermal management and temperature control, while at the same time improve the hydrodynamic (load capacity) performance of the foil bearing. Foil bearings are unique antifriction devices that can utilize the working fluid of a machine as a lubricant (typically air for turbines and motors, liquids for pumps), and as a coolant to remove excess energy due to frictional heating. The current state of the art of foil bearings utilizes forced cooling of the bearing and shaft, which represents poor efficiency and poor reliability. This invention embodies features that utilize the bearing geometry in such a manner as to both support load and provide an inherent and

  10. Analysis of polymer foil heaters as infrared radiation sources

    International Nuclear Information System (INIS)

    Witek, Krzysztof; Piotrowski, Tadeusz; Skwarek, Agata

    2012-01-01

    Infrared radiation as a heat source is used in many fields. In particular, the positive effect of far-infrared radiation on living organisms has been observed. This paper presents two technological solutions for infrared heater production using polymer-silver and polymer-carbon pastes screenprinted on foil substrates. The purpose of this work was the identification of polymer layers as a specific frequency range IR radiation sources. The characterization of the heaters was determined mainly by measurement of the surface temperature distribution using a thermovision camera and the spectral characteristics were determined using a special measuring system. Basic parameters obtained for both, polymer silver and polymer carbon heaters were similar and were as follows: power rating of 10–12 W/dm 2 , continuous working surface temperature of 80–90 °C, temperature coefficient of resistance (TCR) about +900 ppm/K for polymer-carbon heater and about +2000 ppm/K for polymer-silver, maximum radiation intensity in the wavelength range of 6–14 μm with top intensity at 8.5 μm and heating time about 20 min. For comparison purposes, commercial panel heater was tested. The results show that the characteristics of infrared polymer heaters are similar to the characteristics of the commercial heater, so they can be taken into consideration as the alternative infrared radiation sources.

  11. Influence of successive plasma treatments on PP foils

    International Nuclear Information System (INIS)

    Jacobs, T; Morent, R; De Geyter, N; Leys, C

    2011-01-01

    Polypropylene (PP) foil is treated with a dielectric barrier discharge (DBD) plasma operating in helium at medium pressure. The influence of exposure to the atmosphere between successive treatments is studied by varying the exposure time. Each PP sample is treated with subsequent treatment steps of 5 s. Between two treatment steps, different procedures are applied: 1) the sample remains in the discharge chamber at medium pressure (under helium atmosphere) for a certain time before it is treated again or 2) the pressure is increased to atmospheric pressure, so the sample remains exposed to atmospheric air for a certain time and afterwards the system is pumped down again to medium pressure before it undergoes a successive helium plasma treatment. The treated samples are analysed using contact angle measurements. The results show that exposure to the atmosphere between two treatment steps leads to a lower contact angle. The longer the exposure time, the lower the contact angle becomes. Another experiment showed that the treatment effect could be gradually removed by applying several short plasma treatments of 1 s to saturated samples. With every short treatment step, the contact angle becomes higher. It is believed that this is due to etching of the surface. In the near future, both atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) analysis on some selected samples are planned to elucidate the chemical and/or physical nature of the observed phenomena.

  12. GEM Foil Quality Assurance For The ALICE TPC Upgrade

    Science.gov (United States)

    Brücken, Erik; Hildén, Timo

    2018-02-01

    The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC) -based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz). The new ReadOut Chamber (ROC) design is based on Gas Electron Multiplier (GEM) technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, necessitates thorough Quality Assurance (QA) measures. The QA scheme, developed by the ALICE collaboration, will be presented in detail.

  13. GEM Foil Quality Assurance For The ALICE TPC Upgrade

    Directory of Open Access Journals (Sweden)

    Brücken Erik

    2018-01-01

    Full Text Available The ALICE (A Large Ion Collider Experiment experiment at the Large Hadron Collider (LHC at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2 the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC –based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz. The new ReadOut Chamber (ROC design is based on Gas Electron Multiplier (GEM technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, necessitates thorough Quality Assurance (QA measures. The QA scheme, developed by the ALICE collaboration, will be presented in detail.

  14. Beam foil interaction studies for the future stripper of Ganil

    International Nuclear Information System (INIS)

    Baron, E.; Ricaud, C.

    1988-01-01

    The GANIL 3 - cyclotron accelerator complex is to be upgraded in 1989 by increasing the beam energy at the stripper. In view of this modification, the effect of carbon stripper foils of various thicknesses (from 50 to 250 μg/cm 2 ) on the energy spread of Ar, Kr, Xe and Ta beams was measured using the analysing section of the 270 0 spectrometer. Energies ranging from 3.2 to 6.5 MeV/A (i.e corresponding to the future energy range) were used, and intensities of several hundreds of electrical nanoamperes were concentrated over a few mm 2 spot. Unusually large values of the additional energy spread are reported. In addition, charge state distributions of the 6.48 MeV/A Xe and 4.81 MeV/A Ta beams were measured as a function of the carbon thickness, in order to be able to choose how close to the equilibrium thickness the stripper should be, while keeping the energy spread of the outgoing beams within reasonable limits

  15. A low-mass vacuum exit foil for high energy electrons and hadrons

    International Nuclear Information System (INIS)

    Brand, J.F.J. van den; Kaan, A.P.

    1988-01-01

    The low-mass exit-foil system for the spectrometers in the electron-scattering facility at NIKHEF-K is described. It facilitates the achievement of high momentum resolution as well as the possibility to use the spectrometers for detection of not only protons but also deuterons, tritons, 3 He and 4 He. The system is constructed of very thin Kapton and Mylar foils reinforced with Kevlar material and features a differential pumping system. (orig.)

  16. SU-E-T-25: Real Time Simulator for Designing Electron Dual Scattering Foil Systems.

    Science.gov (United States)

    Carver, R; Hogstrom, K; Price, M; Leblanc, J; Harris, G

    2012-06-01

    To create a user friendly, accurate, real time computer simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator should allow for a relatively quick, initial design that can be refined and verified with subsequent Monte Carlo (MC) calculations and measurements. The simulator consists of an analytical algorithm for calculating electron fluence and a graphical user interface (GUI) C++ program. The algorithm predicts electron fluence using Fermi-Eyges multiple Coulomb scattering theory with a refined Moliere formalism for scattering powers. The simulator also estimates central-axis x-ray dose contamination from the dual foil system. Once the geometry of the beamline is specified, the simulator allows the user to continuously vary primary scattering foil material and thickness, secondary scattering foil material and Gaussian shape (thickness and sigma), and beam energy. The beam profile and x-ray contamination are displayed in real time. The simulator was tuned by comparison of off-axis electron fluence profiles with those calculated using EGSnrc MC. Over the energy range 7-20 MeV and using present foils on the Elekta radiotherapy accelerator, the simulator profiles agreed to within 2% of MC profiles from within 20 cm of the central axis. The x-ray contamination predictions matched measured data to within 0.6%. The calculation time was approximately 100 ms using a single processor, which allows for real-time variation of foil parameters using sliding bars. A real time dual scattering foil system simulator has been developed. The tool has been useful in a project to redesign an electron dual scattering foil system for one of our radiotherapy accelerators. The simulator has also been useful as an instructional tool for our medical physics graduate students. © 2012 American Association of Physicists in Medicine.

  17. High quality graphene synthesized by atmospheric pressure CVD on copper foil

    OpenAIRE

    Trinsoutrot, Pierre; Rabot, Caroline; Vergnes, Hugues; Delamoreanu, Alexandru; Zenasni, Aziz; Caussat, Brigitte

    2013-01-01

    International audience; Graphene was synthesized at 1000 °C by Atmospheric Pressure Chemical Vapor Deposition on copper foil from methane diluted in argon and hydrogen. The influence of the main synthesis parameters was studied on 2 × 2 cm2 foils in order to obtain continuous monolayer graphenewithout crystalline defect. The uniformity, crystal quality and number of layers of graphenewere analyzed by Raman spectroscopy and Scanning Electronic Microscopy. First, an increase of the annealing pr...

  18. Models of printed boards for solderless mounting of electronic components by foil perforation method

    Directory of Open Access Journals (Sweden)

    Yefimenko A. A.

    2017-10-01

    Full Text Available The paper presents models of printed circuit boards for an improved foil perforation method. The density of electrical connections of such printed circuit boards is estimated in comparison with circuit boards obtained using the methods of mounting in holes and surface mounting. The technological differences in the manufacture of printed circuit boards for the foil perforation method and the traditional method are considered.

  19. Measurements of Sound Velocity of Laser-Irradiated Iron Foils Relevant to Earth Core Condition

    International Nuclear Information System (INIS)

    Shigemori, K.; Ichinose, D.; Otani, K.; Shiota, T.; Sakaiya, T.; Azechi, H.; Irifune, T.

    2006-01-01

    We have developed a novel method to measure sound velocity of laser-irradiated iron foils by side-on x-ray radiograph technique. Iron foils were irradiated with two-stepped laser pulse to reach the earth's core condition. We obtained not only the sound velocity but also temperature, pressure, shock velocity, compressibility, and particle velocity of the laser-irradiated iron. The experimental results are in good agreements with previous experimental results and with one-dimensional simulation results

  20. The correction of occlusal vertical dimension on tooth wear

    Directory of Open Access Journals (Sweden)

    Rostiny Rostiny

    2007-12-01

    Full Text Available The loss of occlusal vertical dimension which is caused by tooth wear is necessarily treated to regain vertical dimension. Correctional therapy should be done as early possible. In this case, simple and relatively low cost therapy was performed. In unserve loss of occlusal vertical dimension, partial removable denture could be used and the improvement of lengthening anterior teeth using composite resin to improve to regain vertical dimensional occlusion.

  1. Diagnosis and Management of Occlusal Wear: A Case Report

    OpenAIRE

    Thirumurthy, V. R.; Bindhoo, Y. A.; Jacob, Sunil Joseph; Kurien, Anjana; Limson, K. S.; Vidhiyasagar, P.

    2012-01-01

    The rationale for doing full mouth rehabilitation are, when occlusal forces become traumatic hampering the health of periodontal tissues, extensive occlusal diseases, trauma, temporomandibular joint disease and congenital disorders with malformed dentition. Literature exposes that full mouth fixed rehabilitation is one of the taxing procedures in the field of Prosthodontics. A critical aspect for successful occlusal rehabilitation is to determine the aetiology, correct sequence of treatment a...

  2. The correction of occlusal vertical dimension on tooth wear

    OpenAIRE

    Rostiny, Rostiny

    2007-01-01

    The loss of occlusal vertical dimension which is caused by tooth wear is necessarily treated to regain vertical dimension. Correctional therapy should be done as early possible. In this case, simple and relatively low cost therapy was performed. In unserve loss of occlusal vertical dimension, partial removable denture could be used and the improvement of lengthening anterior teeth using composite resin to improve to regain vertical dimensional occlusion.

  3. Outcomes after treatment of acute aortic occlusion.

    Science.gov (United States)

    de Varona Frolov, Serguei R; Acosta Silva, Marcela P; Volo Pérez, Guido; Fiuza Pérez, Maria D

    2015-11-01

    Acute aortic occlusion (AAO) is a rare disease with high morbidity and mortality. The aim of this study was to describe the results of surgical treatment of acute aortic occlusion and risk factors for mortality. Retrospective review of the clinical history of 29 patients diagnosed and operated on for AAO during 28 years. The following variables were analysed: age, sex, tabaco use, diabetes, chronic renal insufficiency, chronic heart failure, atrial fibrillation, arterial hypertension, symptoms, diagnosis and treatment, 30-day mortality and long-term survival. A univariant analysis was performed of variables related to mortality. Twenty-nine patients were included (18 male) with a mean age of 66,2 years. The aetiology was: embolism (EM) in 11 cases and Thrombosis (TR) in 18 cases. The surgical procedures performed included bilateral transfemoral thrombectomy (14 cases), aorto-bifemoral by-pass (8 cases), axilo uni/bifemoral by-pass (5 cases) and aortoiliac and renal tromboendarterectomy (2 cases). Morbidity included: renal failure (14 cases), mesenteric ischemia (4 cases), cardiac complications (7 cases), respiratory complications (5 cases) and loss of extremity (2 cases). The in-hospital mortality was 21% (EM 0%, TR 21%). The estimated survival at 1.3 and 5 years was 60, 50 and 44% respectively. Age (p=0.032), arterial hypertension (p=0.039) and aetiology of the AAO (p=0.039) were related to mortality. Acute aortic occlusion is a medical emergency with high mortality rates. Acute renal failure is the most common postoperative complication. Copyright © 2012 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Central Retinal Vein Occlusion Revealing Coelic Disease

    Directory of Open Access Journals (Sweden)

    Hana ZOUBEIDI

    2016-11-01

    Full Text Available Introduction: Thrombosis has been widely reported in coeliac disease (CD but central retinal vein occlusion (CRVO is rarely described. Case presentation: A 27-year-old woman presented with acute visual loss and was diagnosed with CRVO. Her protein S and protein C levels were low and CD was diagnosed on the basis of endoscopic, immunological and histological results. A gluten-free diet resulted in favourable evolution. Conclusion: CD should be considered in young patients with thrombosis, especially if in an unusual location. Treatment is based on a gluten-free diet.

  5. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, L A; Vliet, H; Pun, A; Gallo, M F

    2004-01-01

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide including various vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), vas irrigation and fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the best available evidence from randomized controlled trials. The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. We searched the computerized databases the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Popline and LILACS. In addition, we searched the reference lists of relevant articles and book chapters. We included randomized controlled trials and controlled clinical trials comparing vasectomy techniques. We assessed all titles and abstracts located in the literature searches and two reviewers independently extracted articles identified for inclusion. Data were presented in the text of the review. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Two trials compared vas occlusion with clips versus a conventional vasectomy technique; both were of poor quality. Neither trial found a difference between the two groups with regard to the primary outcome of failure to reach azoospermia. Four trials examined vas irrigation: three compared water irrigation with no irrigation and one compared water irrigation with euflavine. All of the trials were of poor quality. None of the trials found a significant difference between the groups with respect to the primary outcome of time to azoospermia. However, one trial found that the median number of ejaculations to azoospermia was significantly lower in the euflavine group compared to the water irrigation group. The one trial

  6. Surgical treatment of central retinal vein occlusion.

    Science.gov (United States)

    Berker, Nilufer; Batman, Cosar

    2008-05-01

    The treatment of central retinal vein occlusion (CRVO) is still a subject of debate. Medical therapy efforts, as well as retinal laser photocoagulation, have mostly dealt with management of the sequelae of CRVO, and have shown limited success in improving visual acuity. The unsatisfactory results of such therapeutic efforts led to the development of new treatment strategies focused on the surgical treatment of the occluded retinal vein. The purpose of this review is to summarize the outcomes of commonly reported surgical treatment strategies and to review different opinions on the various surgical approaches to the treatment of CRVO.

  7. Spin-polarized radioactive isotope beam produced by tilted-foil technique

    International Nuclear Information System (INIS)

    Hirayama, Yoshikazu; Mihara, Mototsugu; Watanabe, Yutaka; Jeong, Sun-Chan; Miyatake, Hiroari; Momota, Sadao; Hashimoto, Takashi; Imai, Nobuaki; Matsuta, Kensaku; Ishiyama, Hironobu; Ichikawa, Shin-ichi; Ishii, Tetsuro; Izumikawa, Takuji; Katayama, Ichiro; Kawakami, Hirokane; Kawamura, Hirokazu; Nishinaka, Ichiro; Nishio, Katsuhisa; Makii, Hiroyuki; Mitsuoka, Shin-ichi

    2013-01-01

    Highlights: • Detail study for tilted foil technique. • New equation for estimating nuclear polarization dependence on the beam energy. • Production of nuclear polarization for heaviest nucleus 123 In in ground state. -- Abstract: The tilted-foil method for producing spin-polarized radioactive isotope beams has been studied using the re-accelerated radioactive 8 Li and 123 In beams produced at Tokai Radioactive Ion Accelerator Complex (TRIAC) facility. We successfully produced polarization in a 8 Li beam of 7.3(5)% using thin polystyrene foils (4.2 μg/cm 2 ). The systematic study of the nuclear polarization as a function of the number of foils and beam energy has been performed, confirming the features of the tilted-foil technique experimentally. After the study, a spin-polarized radioactive 123 In beam, which is the heaviest ever polarized in its ground state by this method, has been successfully generated by the tilted-foil method, for the nuclear spectroscopy around the doubly magic nucleus 132 Sn

  8. A Systems Approach to the Solid Lubrication of Foil Air Bearings for Oil-Free Turbomachinery

    Science.gov (United States)

    DellaCorte, Christopher; Zaldana, Antonio R.; Radil, Kevin C.

    2002-01-01

    Foil air bearings are self-acting hydrodynamic bearings which rely upon solid lubricants to reduce friction and minimize wear during sliding which occurs at start-up and shut-down when surface speeds are too low to allow the formation of a hydrodynamic air film. This solid lubrication is typically accomplished by coating the non-moving foil surface with a thin, soft polymeric film. The following paper introduces a systems approach in which the solid lubrication is provided by a combination of self lubricating shaft coatings coupled with various wear resistant and lubricating foil coatings. The use of multiple materials, each providing different functions is modeled after oil-lubricated hydrodynamic sleeve bearing technology which utilizes various coatings and surface treatments in conjunction with oil lubricants to achieve optimum performance. In this study, room temperature load capacity tests are performed on journal foil air bearings operating at 14,000 rpm. Different shaft and foil coating technologies such as plasma sprayed composites, ceramic, polymer and inorganic lubricant coatings are evaluated as foil bearing lubricants. The results indicate that bearing performance is improved through the individual use of the lubricants and treatments tested. Further, combining several solid lubricants together yielded synergistically better results than any material alone.

  9. Alpha Oscillations during Incidental Encoding Predict Subsequent Memory for New "Foil" Information.

    Science.gov (United States)

    Vogelsang, David A; Gruber, Matthias; Bergström, Zara M; Ranganath, Charan; Simons, Jon S

    2018-01-11

    People can employ adaptive strategies to increase the likelihood that previously encoded information will be successfully retrieved. One such strategy is to constrain retrieval toward relevant information by reimplementing the neurocognitive processes that were engaged during encoding. Using EEG, we examined the temporal dynamics with which constraining retrieval toward semantic versus nonsemantic information affects the processing of new "foil" information encountered during a memory test. Time-frequency analysis of EEG data acquired during an initial study phase revealed that semantic compared with nonsemantic processing was associated with alpha decreases in a left frontal electrode cluster from around 600 msec after stimulus onset. Successful encoding of semantic versus nonsemantic foils during a subsequent memory test was related to decreases in alpha oscillatory activity in the same left frontal electrode cluster, which emerged relatively late in the trial at around 1000-1600 msec after stimulus onset. Across participants, left frontal alpha power elicited by semantic processing during the study phase correlated significantly with left frontal alpha power associated with semantic foil encoding during the memory test. Furthermore, larger left frontal alpha power decreases elicited by semantic foil encoding during the memory test predicted better subsequent semantic foil recognition in an additional surprise foil memory test, although this effect did not reach significance. These findings indicate that constraining retrieval toward semantic information involves reimplementing semantic encoding operations that are mediated by alpha oscillations and that such reimplementation occurs at a late stage of memory retrieval, perhaps reflecting additional monitoring processes.

  10. Foil Strain Gauges Using Piezoresistive Carbon Nanotube Yarn: Fabrication and Calibration.

    Science.gov (United States)

    Abot, Jandro L; Góngora-Rubio, Mário R; Anike, Jude C; Kiyono, César Y; Mello, Luis A M; Cardoso, Valtemar F; Rosa, Reinaldo L S; Kuebler, Derek A; Brodeur, Grace E; Alotaibi, Amani H; Coene, Marisa P; Coene, Lauren M; Jean, Elizabeth; Santiago, Rafael C; Oliveira, Francisco H A; Rangel, Ricardo; Thomas, Gilles P; Belay, Kalayu; da Silva, Luciana W; Moura, Rafael T; Seabra, Antonio C; Silva, Emílio C N

    2018-02-05

    Carbon nanotube yarns are micron-scale fibers comprised by tens of thousands of carbon nanotubes in their cross section and exhibiting piezoresistive characteristics that can be tapped to sense strain. This paper presents the details of novel foil strain gauge sensor configurations comprising carbon nanotube yarn as the piezoresistive sensing element. The foil strain gauge sensors are designed using the results of parametric studies that maximize the sensitivity of the sensors to mechanical loading. The fabrication details of the strain gauge sensors that exhibit the highest sensitivity, based on the modeling results, are described including the materials and procedures used in the first prototypes. Details of the calibration of the foil strain gauge sensors are also provided and discussed in the context of their electromechanical characterization when bonded to metallic specimens. This characterization included studying their response under monotonic and cyclic mechanical loading. It was shown that these foil strain gauge sensors comprising carbon nanotube yarn are sensitive enough to capture strain and can replicate the loading and unloading cycles. It was also observed that the loading rate affects their piezoresistive response and that the gauge factors were all above one order of magnitude higher than those of typical metallic foil strain gauges. Based on these calibration results on the initial sensor configurations, new foil strain gauge configurations will be designed and fabricated, to increase the strain gauge factors even more.

  11. PENGEMBANGAN FOIL NACA SERI 2412 SEBAGAI SISTEM PENYELAMAN MODEL KAPAL SELAM

    Directory of Open Access Journals (Sweden)

    Ali Munazid

    2015-06-01

    Full Text Available Bentuk  foil menghasilkan gaya angkat (lift force ketika foil dilewati oleh aliran fluida  karena adanya pengaruh interaksi antara aliran fluida dengan permukaan foil yang mengakibatkan tekanan permukaan atas lebih kecil dari permukaan bawah. Bagaimana mengaplikasikan teori foil pada hydroplane kapal selam sebagai  system penyelaman, dengan membalik foil maka lift force tersebut menjadi gaya ke bawah, dengan demikian memungkinkan kapal selam dapat menyelam, melayang dan bermanouver di bawah air, seperti halnya gerak pesawat terbang yang terbang dan melayang dengan menggunakan sayap. Dilakukan penelitian dan pengamatan terhadap kemampuan penyelaman (diving plan dari foil NACA seri 2412 pada model kapal selam, dengan mencari nilai Cl (coefisien lift di Laboratorium, serta mendesain bentuk badan kapal selam dan analisa gaya-gaya yang bekerja pada model kapal selam, jumlah gaya-gaya yang bekerja keatas lebih rendah dari gaya-gaya ke bawah maka kapal selam mampu menyelam. Penerapan Hydroplane sebagai diving plane dapat diterapkan, kemampuan penyelaman dipengaruhi oleh sudut flip  Hydroplane dan kecepatan model, semakin besar kecepatan dan sudut flip maka semakin besar kedalaman penyelaman yang dapat dilakukan.

  12. Foil Strain Gauges Using Piezoresistive Carbon Nanotube Yarn: Fabrication and Calibration

    Directory of Open Access Journals (Sweden)

    Jandro L. Abot

    2018-02-01

    Full Text Available Carbon nanotube yarns are micron-scale fibers comprised by tens of thousands of carbon nanotubes in their cross section and exhibiting piezoresistive characteristics that can be tapped to sense strain. This paper presents the details of novel foil strain gauge sensor configurations comprising carbon nanotube yarn as the piezoresistive sensing element. The foil strain gauge sensors are designed using the results of parametric studies that maximize the sensitivity of the sensors to mechanical loading. The fabrication details of the strain gauge sensors that exhibit the highest sensitivity, based on the modeling results, are described including the materials and procedures used in the first prototypes. Details of the calibration of the foil strain gauge sensors are also provided and discussed in the context of their electromechanical characterization when bonded to metallic specimens. This characterization included studying their response under monotonic and cyclic mechanical loading. It was shown that these foil strain gauge sensors comprising carbon nanotube yarn are sensitive enough to capture strain and can replicate the loading and unloading cycles. It was also observed that the loading rate affects their piezoresistive response and that the gauge factors were all above one order of magnitude higher than those of typical metallic foil strain gauges. Based on these calibration results on the initial sensor configurations, new foil strain gauge configurations will be designed and fabricated, to increase the strain gauge factors even more.

  13. Foil Strain Gauges Using Piezoresistive Carbon Nanotube Yarn: Fabrication and Calibration

    Science.gov (United States)

    Góngora-Rubio, Mário R.; Kiyono, César Y.; Mello, Luis A. M.; Cardoso, Valtemar F.; Rosa, Reinaldo L. S.; Kuebler, Derek A.; Brodeur, Grace E.; Alotaibi, Amani H.; Coene, Marisa P.; Coene, Lauren M.; Jean, Elizabeth; Santiago, Rafael C.; Oliveira, Francisco H. A.; Rangel, Ricardo; Thomas, Gilles P.; Belay, Kalayu; da Silva, Luciana W.; Moura, Rafael T.; Seabra, Antonio C.; Silva, Emílio C. N.

    2018-01-01

    Carbon nanotube yarns are micron-scale fibers comprised by tens of thousands of carbon nanotubes in their cross section and exhibiting piezoresistive characteristics that can be tapped to sense strain. This paper presents the details of novel foil strain gauge sensor configurations comprising carbon nanotube yarn as the piezoresistive sensing element. The foil strain gauge sensors are designed using the results of parametric studies that maximize the sensitivity of the sensors to mechanical loading. The fabrication details of the strain gauge sensors that exhibit the highest sensitivity, based on the modeling results, are described including the materials and procedures used in the first prototypes. Details of the calibration of the foil strain gauge sensors are also provided and discussed in the context of their electromechanical characterization when bonded to metallic specimens. This characterization included studying their response under monotonic and cyclic mechanical loading. It was shown that these foil strain gauge sensors comprising carbon nanotube yarn are sensitive enough to capture strain and can replicate the loading and unloading cycles. It was also observed that the loading rate affects their piezoresistive response and that the gauge factors were all above one order of magnitude higher than those of typical metallic foil strain gauges. Based on these calibration results on the initial sensor configurations, new foil strain gauge configurations will be designed and fabricated, to increase the strain gauge factors even more. PMID:29401745

  14. Numerical simulation of the pressure pulses produced by a pressure screen foil rotor

    International Nuclear Information System (INIS)

    Feng, M.; Ollivier-Gooch, C.; Gooding, R.W.; Olson, J.A.

    2003-01-01

    Pressure screening is the most industrially efficient and effective means of removing contaminants that degrade the appearance and strength of paper and fractionating fibres for selective treatments and specialty products. A critical design component of a screen is the rotor which produces pressure pulses on the screen cylinder surface to keep the screening apertures clear. To understand the effect of the key design and operating variables for a NACA 0012 foil rotor, a computational fluid dynamic (CFD) simulation tool was developed with FLUENT software, and the numerical results were compared with experimental measurements. The computational results of pressure pulses were shown to be in good agreement with experimental pressure measurements over a wide range of foil tip-speeds, clearances and angles of attack. In addition, it was shown that the magnitude of the pressure pulse peak increases as the rotating speed increases linearly with the square of tip-speed for all the angles of attack studied. The maximum negative pressure pulse occurred for the foil at 5 degrees angle of attack. Flow began to separate from foil surface near the screen plate beyond 10 degrees angle of attack. The positive pressure peak near the leading edge of the foil is completely eliminated for foils operating at a positive angle of attack. The magnitude of the negative pressure peak increased as clearance decreased. In addition to, and more important than, these specific results, we have shown that CFD is a viable tool for the optimal design and operation of rotors in industrial pressure screens. (author)

  15. Development and Application of Integrated Aerodynamic Protuberant Foil Journal and Thrust Bearing in Turboexpander

    Directory of Open Access Journals (Sweden)

    Tianwei Lai

    2017-01-01

    Full Text Available Foil bearing provides compliant support and moderate Coulomb friction for rotor-bearing system, which is conducive to stability and reliability of high speed rotating machinery. In this paper, both hydrodynamic lubricated foil journal and foil thrust bearings are applied in a 150 m3·h−1 turboexpander for air separation. In the bearings, protuberant foil is chosen as the supporting subfoil due to its merits of easy fabrication and assembly. Static loading and deflection of the bearings are tested, respectively, before integration into the turboexpander. Afterwards, the loading and deflection curves of the journal and thrust bearings are polynomial fitted using least-square method. Then, performance tests are carried out on the rotor-bearing system, including transient speed-up, high speed, and speed-down processes. In the tests, the turboexpander supported by the hydrodynamic foil bearings operates smoothly with repeatability. Maximal rotor speed of the turboexpander reaches 52000 rpm with hydrodynamic lubricated protuberant foil bearings.

  16. A foil stripper and terminal steering assembly for an FN tandem

    International Nuclear Information System (INIS)

    Weitkamp, W.G.

    1989-01-01

    The authors report how they recently installed a new foil stripper mechanism and steerer assembly in their FN tandem terminal. The project had the following goals: To significantly increase the number of foils in the tandem. The authors formerly had only a 38 foil capacity. Now that the new superconducting booster is running, demand for foils has increased drastically. To add horizontal steering plates to the vertical steering plates in the terminal. With conventional HVEC inclined field beam tubes, the position of the beam at the exit of the tandem is sensitive to the variation in value of the column resistors. Minor beam tube misalignments can also cause the beam to come out displaced horizontally by an annoying amount. To retain the gas stripper tube. The authors occasionally find it convenient to use gas stripping for low energy heavy ion beams and for ions for which the foil consumption rate is excessive. To electrically insulate all terminal components so the terminal ripple remover will continue to operate. The terminal ripple remover, which is designed to reduce beam energy fluctuations, places a rapidly varying 2-9 kV bias on the stripper foil or stripper gas canal in response to an energy correction signal derived from the image slits. The energy correction signal is transmitted optically to the terminal

  17. Titanium conversion coatings on the aluminum foil AA 8021 used for lithium-ion battery package

    Science.gov (United States)

    Xia, Xu-Feng; Gu, Ying-Ying; Xu, Shi-Ai

    2017-10-01

    In this study, an environment-friendly titanium (Ti) conversion coating was successfully deposited on the aluminum foil AA 8021 in the solution containing hexafluorotitanic acid (H2TiF6), and its morphology, composition, growth process, hydrophilicity and corrosion resistance were characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), energy dispersive spectroscopy (EDS), X-ray photoelectric spectroscopy (XPS), contact-angle measurements (CAM) and salt spray exposure. The peeling strength between the Ti treated Al foil and the modified polypropylene (PP) film (PP grafted with maleic anhydride, PP-g-MAH) (Al/PP-g-MAH) was measured by T-peeling test. The results show that the Ti conversion coating is a multi-component coating composed primarily of metal oxides (TiO2 and Al2O3) and metal fluoride (AlF3). Ti treated Al foil shows better corrosion resistance than untreated and alkali-cleaned Al foils. The peeling strength of PP-g-MAH film with Ti treated Al foils is approximately 30 times higher than that with untreated Al foils. Thus, Ti treatment is a promising approach to improve the corrosion resistance and peeling strength of aluminum/polymer composite film (Al/P) used in the lithium-ion battery package.

  18. Bilateral retinal vein occlusion and rubeosis irides: lessons to learn.

    Science.gov (United States)

    Md Noh, Umi Kalthum; Ahem, Amin; Mustapha, Mushawiahti

    2013-01-01

    Uncontrolled hypertension is well- known to give rise to systemic complications involving multiple central organs. Artherosclerosis leads to damage of the retinal vessels wall, contributing to venous stasis, thrombosis and finally, occlusion. Retinal vein occlusions compromise vision through development of ischaemic maculopathy, macular oedema, and rubeotic glaucoma. Laser photocoagulation remains the definitive treatment for ischaemic vein occlusion with secondary neovascularization. Timely treatment with anti- vascular endothelial growth factor prevents development of rubeotic glaucoma. We hereby report an unusual case of bilateral retinal vein occlusion complicated by rubeosis irides, which was successfully managed to improve vision and prevent rubeotic glaucoma.

  19. Hydrocolloid occlusion for the treatment of neurovascular corns

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Beck, Jan Walther; Reumert, L N

    1991-01-01

    The goal of this study was to determine the effect of hydrocolloid occlusion on neurovascular corns. The design was an observer-blinded, randomized, controlled study. Thirty consecutive patients participated in the trial. The patients received curettage alone or curettage with hydrocolloid...... occlusion. Six treatments were given over 12 weeks. A follow-up examination was performed 3 months after termination of the trial. Outcome measures were the size of the corns, a discomfort score, and an overall judgment of the trial. The results demonstrated no benefit of occlusion for symptoms or signs...... of neurovascular corns. The patients treated with occlusion were, however, generally more satisfied than the conventional group....

  20. Occlusal wear and occlusal condition in a convenience sample of young adults

    NARCIS (Netherlands)

    Spijker, A. van 't; Kreulen, C.M.; Bronkhorst, E.M.; Creugers, N.H.J.

    2015-01-01

    OBJECTIVE: To study progression of tooth wear quantitatively in a convenient sample of young adults and to assess possible correlations with occlusal conditions. METHODS: Twenty-eight dental students participated in a three-year follow up study on tooth wear. Visible wear facets on full arch gypsum

  1. Occlusal wear and occlusal condition in a convenience sample of young adults.

    Science.gov (United States)

    Van't Spijker, A; Kreulen, C M; Bronkhorst, E M; Creugers, N H J

    2015-01-01

    To study progression of tooth wear quantitatively in a convenient sample of young adults and to assess possible correlations with occlusal conditions. Twenty-eight dental students participated in a three-year follow up study on tooth wear. Visible wear facets on full arch gypsum casts were assessed using a flatbed scanner and measuring software. Regression analyses were used to assess possible associations between the registered occlusal conditions 'occlusal guidance scheme', 'vertical overbite', 'horizontal overbite', 'depth of sagittal curve', 'canine Angle class relation', 'history of orthodontic treatment', and 'self-reported grinding/clenching' (independent variables) and increase of wear facets (dependent variable). Mean increase in facet surface areas ranged from 1.2 mm2 (premolars, incisors) to 3.4 mm2 (molars); the relative increase ranged from 15% to 23%. Backward regression analysis showed no significant relation for 'group function', 'vertical overbite', 'depth of sagittal curve', 'history of orthodontic treatment' nor 'self-reported clenching. The final multiple linear regression model showed significant associations amongst 'anterior protected articulation' and 'horizontal overbite' and increase of facet surface areas. For all teeth combined, only 'anterior protected articulation' had a significant effect. 'Self reported grinding' did not have a significant effect (p>0.07). In this study 'anterior protected articulation' and 'horizontal overbite', were significantly associated with the progression of tooth wear. Self reported grinding was not significantly associated with progression of tooth wear. Occlusal conditions such as anterior protected articulation and horizontal overbite seem to have an effect on the progression of occlusal tooth wear in this convenient sample of young adults. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Interventional therapy of atherosclerotic renal artery occlusion

    International Nuclear Information System (INIS)

    Li Jian; Xu Ke; Xiao Liang

    2009-01-01

    Objective: To investigate the effectiveness of interventional therapy for the atherosclerotic renal artery occlusion (ARAO). Methods: During the period of June 2001-Dec. 2007, 16 patients with ARAO (total of 16 occluded arteries) underwent interventional managements, including percutaneous endovascular renal artery revascularization, balloon dilatation angioplasty and stent placement. Follow-up survey was made at regular intervals. The patent condition of the renal artery was evaluated with ultrasonography and digital subtraction angiography. The blood pressure and the renal function were determined and the data were statistically analyzed in order to assess the intermediate and long-term effect of the interventional therapy. Results: Of 16 patients, technical success was achieved in 15 (93.8%) and failure occurred in one. During a follow-up period of 9 - 24 months, 3 patients died. According to the data obtained at each patient's last follow-up survey, the hypertension fell to normal in 3 (25.0%), was improved in 7 (58.3%) and showed no marked change in 2 patients (16.7%), with a clinical efficacy of 83.3% (10 / 12). The renal function was improved in 2 (16.7%), stabilized in 6 (50%) and deteriorated in 4 patients (33.3%), with an effective rate of 66.7% (8 / 12). Conclusion: For the treatment of atherosclerotic renal artery occlusion, the interventional therapy carries high successful rate and can effectively lower the blood pressure level, in addition, it can also protect the renal function in a certain degree. (authors)

  3. Endovascular Management of Central Retinal Arterial Occlusion.

    Science.gov (United States)

    Agarwal, Nitin; Gala, Nihar B; Baumrind, Benjamin; Hansberry, David R; Thabet, Ahmad M; Gandhi, Chirag D; Prestigiacomo, Charles J

    2016-11-01

    Central retinal artery occlusion (CRAO) is an ophthalmologic emergency due to the sudden cessation of circulation to the inner retinal layer. Without immediate treatment, permanent blindness may ensue. Several treatment options exist, ranging from noninvasive medical management to thrombolysis. Nonetheless, ongoing debate exists regarding the best therapeutic strategy. The authors present the case of a 78-year-old woman with a medical history of hypercholesterolemia and rheumatoid arthritis who experienced complete loss of vision in her left eye. Following ophthalmologic evaluation demonstrating left CRAO, anterior chamber paracentesis was performed. Endovascular intervention was performed via local intra-arterial fibrinolysis with alteplase. Her vision returned to 20/20 following the procedure. In general, conventional therapies have not significantly improved patient outcomes. Several management options exist for CRAO. In general, conservative measures have not been reported to yield better patient outcomes as compared to the natural history of this medical emergency. Endovascular approaches are another option as observed with this case reported. In cases of CRAO, therapeutic strategies such as intra-arterial fibrinolysis utilize a local infusion of reactive tissue plasminogen activator directly at the site of occlusion via catheterization of the ophthalmic artery. Although several case series do show promising results after treating CRAO with intra-arterial fibrinolysis, further studies are required given the reports of complications.

  4. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, Lynley A; Van Vliet, Huib A A M; Lopez, Laureen M; Pun, Asha; Gallo, Maria F

    2014-03-30

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide, including vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), as well as vasectomy with vas irrigation or with fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the evidence from randomized controlled trials (RCTs). The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. In February 2014, we updated the searches of CENTRAL, MEDLINE, POPLINE and LILACS. We looked for recent clinical trials in ClinicalTrials.gov and the International Clinical Trials Registry Platform. Previous searches also included EMBASE. For the initial review, we searched the reference lists of relevant articles and book chapters. We included RCTs comparing vasectomy techniques, which could include suture ligature, surgical clips, thermal or electrocautery, chemical occlusion, vas plugs, vas excision, open-ended vas, fascial interposition, or vas irrigation. We assessed all titles and abstracts located in the literature searches. Two reviewers independently extracted data from articles identified for inclusion. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Peto odds ratios (OR) with 95% confidence intervals (CI) were used for dichotomous outcomes, such as azoospermia. The mean difference (MD) was used for the continuous variable of operating time. Six studies met the inclusion criteria. One trial compared vas occlusion with clips versus a conventional vasectomy technique. No difference was found in failure to reach azoospermia (no sperm detected). Three trials examined vasectomy with vas irrigation. Two studies looked at irrigation with water versus no

  5. Influence of denture adhesives on occlusion and disocclusion times.

    Science.gov (United States)

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (Pstability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Measurements by activation foils and comparative computations by MCNP code

    International Nuclear Information System (INIS)

    Kyncl, J.

    2008-01-01

    Systematic study of the radioactive waste minimisation problem is subject of the SPHINX project. Its idea is that burning or transmutation of the waste inventory problematic part will be realized in a nuclear reactor the fuel of which is in the form of liquid fluorides. In frame of the project, several experiments have been performed with so-called inserted experimental channel. The channel was filled up by the fluorides mixture, surrounded by six fuel assemblies with moderator and placed into LR-0 reactor vessel. This formation was brought to critical state and measurement with activation foil detectors were carried out at selected positions of the inserted channel. Main aim of the measurements was to determine reaction rates for the detectors mentioned. For experiment evaluation, comparative computations were accomplished by code MCNP4a. The results obtained show that very often, computed values of reaction rates differ substantially from the values that were obtained from the experiment. This contribution deals with analysis of the reasons of these differences from the point of view of computations by Monte Carlo method. The analysis of concrete cases shows that the inaccuracy of reaction rate computed is caused mostly by three circumstances:-space region that is occupied by detector is relatively very small;- microscopic effective cross-section R(E) of the reaction changes strongly with energy just in the energy interval that gives the greatest contribution to the reaction; - in the energy interval that gives the greatest contribution to reaction rate, the error of the computed neutron flux is great. These circumstances evoke that the computation of reaction rate with casual accuracy submits extreme demands on computing time. (Author)

  7. Intense heavy ion beam-induced effects in carbon-based stripper foils

    Energy Technology Data Exchange (ETDEWEB)

    Kupka, Katharina

    2016-08-15

    Amorphous carbon or carbon-based stripper foils are commonly applied in accelerator technology for electron stripping of ions. At the planned facility for antiproton and ion research (FAIR) at the Helmholtzzentrum fuer Schwerionenforschung (GSI), Darmstadt, thin carbon stripper foils provide an option for directly delivering ions of intermediate charge states to the heavy ion synchrotron, SIS 18, in order to mitigate space charge limitations during high-intensity operation. In case of desired high end-energies in the synchrotron, a second stripping process by a thicker carbon foil provides ions of higher charge states for injection into the SIS18. High beam intensities and a pulsed beam structure as foreseen at FAIR pose new challenges to the stripper foils which experience enhanced degradation by radiation damage, thermal effects, and stress waves. In order to ensure reliable accelerator operation, radiation-hard stripper foils are required. This thesis aims to a better understanding of processes leading to degradation of carbon-based thin foils. Special focus is placed on ion-beam induced structure and physical property changes and on the influence of different beam parameters. Irradiation experiments were performed at the M3-beamline of the universal linear accelerator (UNILAC) at GSI, using swift heavy ion beams with different pulse lengths and repetition rates. Tested carbon foils were standard amorphous carbon stripper foils produced by the GSI target laboratory, as well as commercial amorphous and diamond-like carbon foils and buckypaper foils. Microstructural changes were investigated with various methods such as optical microscopy, scanning electron microscopy (SEM), profilometry and chromatic aberration measurements. For the investigation of structural changes X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, high resolution transmission electron microscopy (HRTEM), in-situ Fourier-transform infrared spectroscopy (FTIR) and small angle X

  8. Intense heavy ion beam-induced effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    Kupka, Katharina

    2016-08-01

    Amorphous carbon or carbon-based stripper foils are commonly applied in accelerator technology for electron stripping of ions. At the planned facility for antiproton and ion research (FAIR) at the Helmholtzzentrum fuer Schwerionenforschung (GSI), Darmstadt, thin carbon stripper foils provide an option for directly delivering ions of intermediate charge states to the heavy ion synchrotron, SIS 18, in order to mitigate space charge limitations during high-intensity operation. In case of desired high end-energies in the synchrotron, a second stripping process by a thicker carbon foil provides ions of higher charge states for injection into the SIS18. High beam intensities and a pulsed beam structure as foreseen at FAIR pose new challenges to the stripper foils which experience enhanced degradation by radiation damage, thermal effects, and stress waves. In order to ensure reliable accelerator operation, radiation-hard stripper foils are required. This thesis aims to a better understanding of processes leading to degradation of carbon-based thin foils. Special focus is placed on ion-beam induced structure and physical property changes and on the influence of different beam parameters. Irradiation experiments were performed at the M3-beamline of the universal linear accelerator (UNILAC) at GSI, using swift heavy ion beams with different pulse lengths and repetition rates. Tested carbon foils were standard amorphous carbon stripper foils produced by the GSI target laboratory, as well as commercial amorphous and diamond-like carbon foils and buckypaper foils. Microstructural changes were investigated with various methods such as optical microscopy, scanning electron microscopy (SEM), profilometry and chromatic aberration measurements. For the investigation of structural changes X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, high resolution transmission electron microscopy (HRTEM), in-situ Fourier-transform infrared spectroscopy (FTIR) and small angle X

  9. Prediction and characterization of heat-affected zone formation due to neighboring nickel-aluminum multilayer foil reaction

    Energy Technology Data Exchange (ETDEWEB)

    Adams, David P. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Hirschfeld, Deidre A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Hooper, Ryan J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Manuel, Michelle V. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Reactive multilayer foils have the potential to be used as local high intensity heat sources for a variety of applications. Much of the past research effort concerning these materials have focused on understanding the structure-property relationships of the foils that govern the energy released during a reaction. To enhance the ability of researchers to more rapidly develop technologies based on reactive multilayer foils, a deeper and more predictive understanding of the relationship between the heat released from the foil and microstructural evolution in the neighboring materials is needed. This work describes the development of a numerical model for the purpose of evaluating new foil-substrate combinations for screening and optimization. The model is experimentally validated using a commercially available Ni-Al multilayer foils and different alloys.

  10. Monoenergetic ion beams from ultrathin foils irradiated by ultrahigh-contrast circularly polarized laser pulses

    Directory of Open Access Journals (Sweden)

    O. Klimo

    2008-03-01

    Full Text Available Acceleration of ions from ultrathin foils irradiated by intense circularly polarized laser pulses is investigated using one- and two-dimensional particle simulations. A circularly polarized laser wave heats the electrons much less efficiently than the wave of linear polarization and the ion acceleration process takes place on the front side of the foil. The ballistic evolution of the foil becomes important after all ions contained in the foil have been accelerated. In the ongoing acceleration process, the whole foil is accelerated as a dense compact bunch of quasineutral plasma implying that the energy spectrum of ions is quasimonoenergetic. Because of the ballistic evolution, the velocity spread of an accelerated ion beam is conserved while the average velocity of ions may be further increased. This offers the possibility to control the parameters of the accelerated ion beam. The ion acceleration process is described by the momentum transfer from the laser beam to the foil and it might be fairly efficient in terms of the energy transferred to the heavy ions even if the foil contains a comparable number of light ions or some surface contaminants. Two-dimensional simulations confirm the formation of the quasimonoenergetic spectrum of ions and relatively good collimation of the ion bunch, however the spatial distribution of the laser intensity poses constraints on the maximum velocity of the ion beam. The present ion acceleration mechanism might be suitable for obtaining a dense high energy beam of quasimonoenergetic heavy ions which can be subsequently applied in nuclear physics experiments. Our simulations are complemented by a simple theoretical model which provides the insights on how to control the energy, number, and energy spread of accelerated ions.

  11. Annealing of (DU-10Mo)-Zr Co-Rolled Foils

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Robin Montoya [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Alexander, David John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mccabe, Rodney James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Clarke, Kester Diederik [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Scott, Jeffrey E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Montalvo, Joel Dwayne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Papin, Pallas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ansell, George S. [Colorado School of Mines, Golden, CO (United States)

    2017-01-20

    Producing uranium-10wt% molybdenum (DU-10Mo) foils to clad with Al first requires initial bonding of the DU-10Mo foil to zirconium (Zr) by hot rolling, followed by cold rolling to final thickness. Rolling often produces wavy (DU-10Mo)-Zr foils that should be flattened before further processing, as any distortions could affect the final alignment and bonding of the Al cladding to the Zr co-rolled surface layer; this bonding is achieved by a hot isostatic pressing (HIP) process. Distortions in the (DU-10Mo)-Zr foil may cause the fuel foil to press against the Al cladding and thus create thinner or thicker areas in the Al cladding layer during the HIP cycle. Post machining is difficult and risky at this stage in the process since there is a chance of hitting the DU-10Mo. Therefore, it is very important to establish a process to flatten and remove any waviness. This study was conducted to determine if a simple annealing treatment could flatten wavy foils. Using the same starting material (i.e. DU-10Mo coupons of the same thickness), five different levels of hot rolling and cold rolling, combined with five different annealing treatments, were performed to determine the effect of these processing variables on flatness, bonding of layers, annealing response, microstructure, and hardness. The same final thickness was reached in all cases. Micrographs, textures, and hardness measurements were obtained for the various processing combinations. Based on these results, it was concluded that annealing at 650°C or higher is an effective treatment to appreciably reduce foil waviness.

  12. Treatment strategies for extensive chronic SFA occlusions : indications and results

    NARCIS (Netherlands)

    Lensvelt, M. M. A.; Reijnen, M. M. P. J.; De Vries, B. M. Wallis; Zeebregts, C. J.

    Treatment modalities for extensive chronic occlusive disease of the superficial femoral artery (SFA) have changed during the last decades. In this chapter we provide an overview of current treatment modalities for extensive chronic occlusive disease of the SFA. Although the autologous venous conduit

  13. Treatment strategies for extensive chronic SFA occlusions: indications and results.

    NARCIS (Netherlands)

    Lensvelt, M.M.A.; Reijnen, M.M.P.J.; Wallis de Vries, B.M.; Zeebregts, C.J.A.

    2012-01-01

    Treatment modalities for extensive chronic occlusive disease of the superficial femoral artery (SFA) have changed during the last decades. In this chapter we provide an overview of current treatment modalities for extensive chronic occlusive disease of the SFA. Although the autologous venous conduit

  14. Vascular occlusion in cut rose flowers - a survey

    NARCIS (Netherlands)

    Doorn, van W.G.

    1995-01-01

    The causes of low water uptake and water stress symptoms in cut rose flowers are briefly reviewed. Low water uptake is due to an occlusion, mainly located in the basal stem end. No evidence has been found for a reaction of the plant after cutting, in the formation of this occlusion. The blockage has

  15. Occlusal Therapy in the Management of Chronic Orofacial Pain

    OpenAIRE

    Bush, Francis M.

    1984-01-01

    Review of the literature indicates that most routine orofacial dysfunctions are characterized by deep pain. Various disorders of the masticatory systems, particularly musculoskeletal conditions, are thought to be triggered by occlusal disharmonies. The pain component develops following a pattern of bruxism, muscle hyperactivity, fatigue and spasm. Treatment for most disorders has been to modify the occlusion, although the rational for doing so appears questionable.

  16. Punctal occlusion with Prolene suture material in the patients with ...

    African Journals Online (AJOL)

    Aim: To analyze the efficacy and outcomes of punctal occlusion with 5-0 Prolene suture material for the treatment of dry eye. Materials and. Methods: A total of 20 patients with moderate and severe dry eyes, recalcitrant to maximal medical therapy, underwent temporary punctal occlusion with 5-0 Prolene suture material.

  17. Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography

    International Nuclear Information System (INIS)

    Kim, Jae Duk; Kim, Jin Soo; You, Choong Hyun

    2005-01-01

    To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occulsion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  18. Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk; Kim, Jin Soo; You, Choong Hyun [Chosun University College of Medicine, Kwangju (Korea, Republic of)

    2005-03-15

    To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occulsion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  19. An Investigation of the Posterior Component of Occlusal Force

    Science.gov (United States)

    1994-05-01

    the dental arch across the midline and examined mandibula deformation in subjects with osseointegrated implants . The authors found that, with maximum...the 58 tongue and cheek musculature. Future studies may consider examining interdental forces between a natural dentition and osseointegrated implants ... dental occlusion forces, and 4. periodontal membrane forces. A stable occlusion would purportedly result when balance in terms of the magnitude

  20. Vertical dimension of occlusion in implant dentistry: significance and approach.

    Science.gov (United States)

    Gittelson, Glenn L

    2002-01-01

    Understanding the principles of occlusion as they relate to managing bite forces on implants is extremely important to maintain the longevity of dental implant prostheses. Specifically, altering vertical dimension of occlusion (VDO) scientifically and predictably is critical to the creation of proper tooth form and guidance when fabricating a full-arch implant-supported prosthesis.

  1. A novel experimental design model for increasing occlusal vertical dimension.

    Science.gov (United States)

    Li, Yan; Zhang, Zhiguang; Wu, Shuyi; Qiao, Yonggang

    2010-03-01

    This study aimed to establish a rat model of increasing occlusal vertical dimension (iOVD) using a prosthodontic approach. The OVD was increased by bonding a maxillary, bilateral, posterior dental splint with a bearing ball while the occlusal stops that were made on the stone casts adjusted the occlusion and bonded in the mouths of adult Wistar rats (iOVD group); the controls did not receive a splint. Both groups were subdivided after splint insertion: 3 days and 1, 2, 3, or 4 weeks (n = 6/subgroup). The effects of iOVD were evaluated by radiographs, body weight, and histologic diagnosis of tooth and temporomandibular joints. There were no differences in body weights between the 2 groups; occlusal asymmetric dentition abrasions did not occur in the iOVD rats. The occlusal splints caused the remodeling of the periodontal tissue and condylar cartilage. Overall, an iOVD rat model can be constructed using prosthodontic techniques ensuring a balance of bilateral occlusal height. OVD, occlusal vertical dimension; iOVD, increasing occlusal vertical dimension; TMJ, temporomandibular joint; TMD, temporomandibular disorders.

  2. Immediate occlusal versus non-occlusal loading of single zirconia implants. A multicentre pragmatic randomised clinical trial.

    Science.gov (United States)

    Cannizzaro, Gioacchino; Torchio, Cinzia; Felice, Pietro; Leone, Michele; Esposito, Marco

    2010-01-01

    To evaluate whether immediate non-occlusal loading of single zirconia implants could reduce early failures when compared to immediate occlusal loading. Forty partially edentulous patients who received one single zirconia implant (Z-Systems) at least 10 mm long and 3.25 mm wide inserted with a torque of at least 35 Ncm were randomised to immediate occlusal or non-occlusal loading groups. All patients received provisional acrylic crowns the same day of implant placement. Provisional crowns were replaced after 4 to 5 months by definitive full ceramic crowns. Outcome measures were implant success, any complications and peri-implant marginal bone levels. One year after loading, no patients had dropped out. Five implants (12.5%) failed early: three occlusally loaded and two non-occlusally loaded. Three complications occurred, all after delivery of the definitive crowns: one crown fractured (occlusal loading), one had to be remade after debridement because of hyperplastic tissues (occlusal loading), and one crown decemented (nonocclusal loading). These differences were not statistically significant. Both groups gradually lost periimplant bone in a highly statistically significant way. One year after loading, patients subjected to non-occlusal loading lost an average of 0.7 mm of peri-implant bone versus 0.9 mm in the occlusal group. This difference in bone loss between groups was not statistically significant. There was an association between immediate post-extractive implants and implant failures (P=0.01). Four of the 10 immediate post-extractive implants (40%) failed versus one out of 30 delayed implants (3%). The results of this study do not provide a conclusive answer to whether immediate non-occlusal loading may decrease implant failures. Immediately loaded zirconia implants placed in post-extractive sites had high failure rates.

  3. Occlusal tooth wear in patients of a dental school's prosthodontic department in Xi'an, China

    NARCIS (Netherlands)

    Meng, M.; Zhang, Q.; Witter, D.J.; Bronkhorst, E.M.; Creugers, N.H.J.; Ma, C.; Zhang, S.

    2014-01-01

    PURPOSE: To assess the relationships between occlusal tooth wear and occlusal conditions, chewing side preference, and occlusal guidance scheme. MATERIALS AND METHODS: A total of 257 Chinese adult dental school patients were categorized according to a hierarchical functional classification system.

  4. [Single- and multi-unit fixed dental prostheses in relation to the occlusal system

    NARCIS (Netherlands)

    Witter, D.J.; Gerritsen, A.E.; Spijker, A. van 't; Creugers, N.H.J.

    2013-01-01

    Occlusion concepts based on functional aspects offer more solid ground in the diagnostic process and in the treatment of (reduced) dentitions than morphologically and mechanically oriented occlusion concepts. Nevertheless, for occlusal reconstruction morphologically oriented guidelines are

  5. Epidemiology of aortic disease - aneurysm, dissection, occlusion

    International Nuclear Information System (INIS)

    Steckmeier, B.

    2001-01-01

    The physiological infrarenal aortic diameter varies between 12.4 mm in women an 27.6 mm in men. As defined, an aneurysmatic dilatation begins with 29 mm. According to that, 9% of all people above the age of 65 are affected by an abdominal aortic aneurysm (AAA). Compared with the female sex, the male sex predominates at a rate of about 5:1. The disease is predominant in men of the white race. In black men, black and white women the incidence of AAA is identical. 38 to 50 percent of the AAA patients (patients) suffer from hypertension, 33 to 60% from coronary, 28% from cerebrovascular and 25% from peripheral occlusive disease. The AAA expansion rate varies between 0.2 and 0.8 cm per year and is exponential from a diameter of 5 cm on. In autopsy studies, the rupture rates with AAA diameters of 7 cm were below 5%, 39% and 65%, respecitvely. 70% of the AAA patients do not die of a rupture, but of a cardiac disease. Serum markers, such as metalloproteinases and procollagen peptides are significantly increased in AAA patients. Thoraco-abdominal aneurysms (TAA) make up only 2 to 5% of all degenerative aneurysms. 20 to 30% of the TAA patients are also affected by an AAA. 80% of the TAA are degenerative, 15 to 20% are a consequence of the chronic dissection - including 5% of Marfan patients -, 2% occur in case of infections and 1 to 2% in case of aortitis. The TAA incidence in 100,000 person-years is 5.9% during a monitoring period of 30 years. In case of TAA, an operation is indicated with a maximum diameter of 5.5 to 6 cm and more and, in case of a Marfan's syndrome (incidence of 1:10,000), with a maximum diameter of 5.5 cm and more. With regard to aorto-iliac occlusive diseases, there are defined 3 types of distribution. Type I refers to the region of the bifurcation itself. Type II defines the diffuse aortoiliac spread of the disease. Type III designates multiple-level occlusions also beyond the inguinal ligament. Type I patients in most cases are female and more

  6. Relationship between heating atmosphere and copper foil impurities during graphene growth via low pressure chemical vapor deposition

    OpenAIRE

    Çelik, Yasemin; Escoffier, Walter; Yang, Ming; Flahaut, Emmanuel; Suvacı, Ender

    2016-01-01

    International audience; Low-pressure chemical vapor deposition synthesis of graphene films on two different Cu foils, with different surface oxygen and carbon contents, was performed by controlling H2 and/or Ar flow rates during heating. The influences of heating atmosphere on the final impurity level, quality of the synthesized graphene films and thickness uniformity were investigated depending on Cu foil impurities. Heating of carbon-rich, but oxygen-poor Cu foil in H2 environment resulted ...

  7. Collateral Circulation in Chronic Total Occlusions - An Interventional Perspective

    Science.gov (United States)

    Choo, Gim-Hooi

    2015-01-01

    Human coronary collaterals are inter-coronary communications that are believed to be present from birth. In the presence of chronic total occlusions, recruitment of flow via these collateral anastomoses to the arterial segment distal to occlusion provide an alternative source of blood flow to the myocardial segment at risk. This mitigates the ischemic injury. Clinical outcome of coronary occlusion ie. severity of myocardial infarction/ischemia, impairment of cardiac function and possibly survival depends not only on the acuity of the occlusion, extent of jeopardized myocardium, duration of ischemia but also to the adequacy of collateral circulation. Adequacy of collateral circulation can be assessed by various methods. These coronary collateral channels have been used successfully as a retrograde access route for percutaneous recanalization of chronic total occlusions. Factors that promote angiogenesis and further collateral remodeling ie. arteriogenesis have been identified. Promotion of collateral growth as a therapeutic target in patients with no suitable revascularization option is an exciting proposal.

  8. Collateral Circulation in Chronic Total Occlusions - an interventional perspective.

    Science.gov (United States)

    Choo, Gim-Hooi

    2015-09-09

    Human coronary collaterals are inter-coronary communications that are believed to be present from birth. In the presence of chronic total occlusions, recruitment of flow via these collateral anastomoses to the arterial segment distal to occlusion provide an alternative source of blood flow to the myocardial segment at risk. This mitigates the ischemic injury. Clinical outcome of coronary occlusion ie. severity of myocardial infarction/ischemia, impairment of cardiac function and possibly survival depends not only on the acuity of the occlusion, extent of jeopardized myocardium, duration of ischemia but also to the adequacy of collateral circulation. Adequacy of collateral circulation can be assessed by various methods. These coronary collateral channels have been used successfully as a retrograde access route for percutaneous recanalization of chronic total occlusions. Factors that promote angiogenesis and further collateral remodeling ie. arteriogenesis have been identified. Promotion of collateral growth as a therapeutic target in patients with no suitable revascularization option is an exciting proposal.

  9. Structural equation modeling for alteration of occlusal plane inclination.

    Science.gov (United States)

    Shigeta, Yuko; Ogawa, Takumi; Nakamura, Yoshiharu; Ando, Eriko; Hirabayashi, Rio; Ikawa, Tomoko

    2015-07-01

    Occlusal plane inclination is important to maintain a normal opening closing/biting function. However, there can be several causes that lead to alterations of the occlusal plane. The purpose of this study was to observe variations of occlusal plane inclination in adult patients, and to uncover the factors affecting changes in occlusal plane inclination with aging. Subjects were 143 patients. A cephalometric image was taken of these patients. In this study, our inquiry points were age, 3 variables on intra-oral findings, and 7 variables on cephalometric analysis. To evaluate the possible causes that affect occlusal plane inclination, factor analysis was carried out, and each component was treated as factors, which were then statistically applied to a structural equation model. Statistical analysis was carried out through the SPSS 20.0 (SPSS Inc., Chicago, USA). In all patients, Camper-occlusal plane angle (COA) ranged from -25.7 to -4.9° (Mean±SD: -6.4±5.36). In the 60 patients who had no missing teeth, COA ranged from -11.6 to -4.9° (Mean±SD: -3.3±3.31). From the results of the structural analysis, it was suggested that the occlusal plane changes to counter-clockwise (on the right lateral cephalograms) with aging. In this study, variations of occlusal plane inclination in adult patients were observed, and the factors affecting changes in occlusal plane inclination with aging were investigated via factor analysis. From our results, it was suggested that the mandibular morphology change and loss of teeth with aging influence occlusal plane inclination. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. [Gnathosonics study of the occlusal stability of orthodontic patients].

    Science.gov (United States)

    Jiang, Ruo-Ping; Tyson, Kenneth W

    2008-02-18

    To analysis the stability of the occlusion before and after the orthodontic treatment by gnathosonics; To evaluate the reliability of the stethoscope method by comparing the subjective(stethoscopy) and objective(digital occlusal sound recording) methods of checking the occlusal sound. Sixty-four new patients with malocclusion were selected as the before treatment group, these patients were not subject to any previous orthodontic treatment, facial surgery or injury; the treatment complete group included 15 patients who were just debonded the fixed appliance. Both stethoscope and digital occlusal sound recording were used to evaluate the occlusal sound. The occlusal stability before and after orthodontic treatment was compared depending on the results from the objective examination. The stability of the occlusion between different types of malocclusion before treatment was compared also. The veracity and reliability of the stethoscope method were analysis using the objective method as the golden standard. (1) 43.75%(28/64) of the 64 new patients showed unstable occlusal sound. ANOVA test showed that there were no statistically significant differences between the unstable rates in different type of malocclusion. (2) 40% (6/15) of the 15 treatment complete patients had unstable occlusions. (3) There were no statistically significant differences between the unstable rate pre- and post-treatment. (4) The veracity of the stethoscopes was 81.01% (64/79). (5) Kappa test showed that the stethoscopes and the digital recording method were consistent; the Kappa value was 0.488, Pocclusion rate between the two groups, and between the different types of malocclusion before treatment. (2) Using stethoscopes method to check the occlusal sound is reliable. The veracity could be improved significantly with increased experiences.

  11. Post partum occlusion of the hepatic artery

    International Nuclear Information System (INIS)

    Buecheler, E.; Hagemann, J.; Remmecke, J.; Hamburg Univ.

    1980-01-01

    A case of post partum acute thrombosis of the hepatic artery with infarction of the liver is reported. The prognosis depends on the areas of obstruction, on the early development of a collateral circulation and on the contribution to the blood supply from the portal vein. The diagnosis of liver infarction was made by computed tomography. This was characterised by sharply demarkated hypodense areas, which did not enhance with contrast. An important clue is the lack of increase in density in the liver after intravenous injection of contrast when compared with the increased contrast of the spleen. This finding provided the indication for angiography. This confirmed the diagnosis of acute occlusion and made appropriate treatment possible. (orig.) [de

  12. Aortitis and aortic occlusion in Crohn disease.

    Science.gov (United States)

    Delay, Charline; Schwein, Adeline; Lejay, Anne; Gaertner, Sébastien; Aleil, Boris; Thaveau, Fabien; Georg, Yannick; Chakfe, Nabil

    2015-02-01

    Patients with Crohn disease (CD) or ulcerative colitis are known to be at increased risk of arterial thromboembolic complications. We report the case of a 33-year-old woman suffering from CD for 19 years who presented lower limb claudication. Computed tomography scan revealed an aortoiliac occlusion extending from the level of the inferior mesenteric artery to both iliac bifurcations. Endovascular recanalization was attempted as a first option but failed. We then performed an aortobi-femoral bypass through a left retroperitoneal approach that allowed a total relief of the symptoms. Histologic study of the aorta demonstrated a nonspecific aortitis with lymphohistiocytic cell infiltration in the media and adventitia tunica. There was no signs of associated vasculitis. At the light of a literature review, we discussed our surgical strategy and the inflammation of the aortic wall as local factor of thrombosis that has never been previously described. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Nanodiamond Foils for H- Stripping to Support the Spallation Neutron Source (SNS) and Related Applications

    Energy Technology Data Exchange (ETDEWEB)

    Vispute, R D [Blue Wave Semiconductors; Ermer, Henry K [Blue Wave Semiconductors; Sinsky, Phillip [Blue Wave Semiconductors; Seiser, Andrew [Blue Wave Semiconductors; Shaw, Robert W [ORNL; Wilson, Leslie L [ORNL; Harris, Gary [Howard University; Piazza, Fabrice [Pontifica Universidad Catolica Madre y Maestra, Dominican Republic

    2013-01-01

    Thin diamond foils are needed in many particle accelerator experiments regarding nuclear and atomic physics, as well as in some interdisciplinary research. Particularly, nanodiamond texture is attractive for this purpose as it possesses a unique combination of diamond properties such as high thermal conductivity, mechanical strength and high radiation hardness; therefore, it is a potential material for energetic ion beam stripper foils. At the ORNL Spallation Neutron Source (SNS), the installed set of foils must be able to survive a nominal five-month operation period, without the need for unscheduled costly shutdowns and repairs. Thus, a single nanodiamond foil about the size of a postage stamp is critical to the entire operation of SNS and similar sources in U.S. laboratories and around the world. We are investigating nanocrystalline, polycrystalline and their admixture films fabricated using a hot filament chemical vapor deposition (HFCVD) system for H- stripping to support the SNS at Oak Ridge National Laboratory. Here we discuss optimization of process variables such as substrate temperature, process gas ratio of H2/Ar/CH4, substrate to filament distance, filament temperature, carburization conditions, and filament geometry to achieve high purity diamond foils on patterned silicon substrates with manageable intrinsic and thermal stresses so that they can be released as free standing foils without curling. An in situ laser reflectance interferometry tool (LRI) is used for monitoring the growth characteristics of the diamond thin film materials. The optimization process has yielded free standing foils with no pinholes. The sp3/sp2 bonds are controlled to optimize electrical resistivity to reduce the possibility of surface charging of the foils. The integrated LRI and HFCVD process provides real time information on the growth of films and can quickly illustrate growth features and control over film thickness. The results are discussed in the light of development

  14. Thrombophilic screening in retinal artery occlusion patients

    Directory of Open Access Journals (Sweden)

    Valeria Nagy

    2008-10-01

    Full Text Available Valeria Nagy1, Lili Takacs1, Zita Steiber1, György Pfliegler2, Andras Berta11Department of Ophthalmology, 2Division of Rare Diseases, University of Debrecen Medical and Health Science Center, Debrecen, HungaryBackground: Retinal artery occlusion (RAO is an ischemic vascular damage of the retina, which frequently leads to sudden, mostly irreversible loss of vision. In this study, blood thrombophilic factors as well as cardiovascular risk factors were investigated for their relevance to this pathology. Thrombophilic risk factors so far not evaluated were included in the study.Patients and methods: 28 RAO patients and 81 matched control subjects were examined. From blood samples, protein C, protein S, antithrombinopathy, and factor V (Leiden mutation (FV, factor II gene polymorphism, factor VIII C level, plasminogen activity, lipoprotein(a and fibrinogen levels, hyperhomocysteinemia and presence of anticardiolipin – antiphospholipid antibodies were investigated. Possibly relevant pathologies such as diabetes mellitus, hypertension, and ischemic heart disease were also registered. Statistical analysis by logistic regression was performed with 95% confidence intervals.Results: In the group of patients with RAO only the incidence of hypertension (OR: 3.33, 95% CI: 1.30–9.70, p = 0.014 as an average risk factor showed significant difference, but thrombophilic factors such as hyperfibrinogenemia (OR: 2.9, 95% CI: 1.29–6.57, p = 0.010 and the presence of FV (Leiden mutation (OR: 3.9, 95% CI: 1.43–10.96, p = 0.008 increased the chances of developing this disease.Conclusions: Our results support the assumption that thrombophilia may contribute to the development of RAO besides vascular damage due to the presence of cardiovascular risk factors. Further studies are needed, however, to justify the possible use of secondary prophylaxis in form of anticoagulant/antiplatelet therapy.Keywords: retinal arterial occlusion, risk factors, thrombophilia

  15. STUDY OF THE DISTANCE BETWEEN LINGULA AND MANDIBULAR OCCLUSAL PLANE IN IRANIAN MALES WITH NORMAL OCCLUSION

    Directory of Open Access Journals (Sweden)

    M GHOREYSHIAN

    2002-09-01

    Full Text Available Introduction. Pain and the need for controlling it is a determinant factor in dental treatment procedures. One of the most common methods of local anesthesia in mandibular area is infra alveolar nerve block which has failure rate of 5% to 15%. The purpose of this study was to locate the optimal needle entrance point in order to achieve a fast, deep and durable anesthesia with minimal anesthetic consumption. Methods. This cross-sectional study has been performed on 38 cadavers of Iranian males with approximate age of more than 17 years. old. They had normal occlusion and at least 2 molars in each quadrant of the mandible if a sample was edentulous in one quadrant of the mandible or in the opposite jaw; or when a severe tilt in mandi bular dentition was present and in the case of mandibular or condylar fracture, the sample was excluded from the study. Distance between lingual and occlusal plane was measured by a device with two parallel plates. The precision of the measurment was 1mm. Data was analysed by the use of SPSS software. Results. On the right side, the average distance between lingual and occlusal plane was 2.4 ± 4.4 (Mean ± SD and on the left side, was 2:r.4.4 which there was no significant difference between right and left sides (P value=0.9. Discussion. In this study the human body is used and the best point for entrance of the needle for inferior alveolar nerve block technique is located at 8mm above the occlusal plane. At this point the anesthetic solution will be evacuated in the nearest position to the inferior alveolar never.

  16. Ultrasonic-Assisted Incremental Microforming of Thin Shell Pyramids of Metallic Foil

    Directory of Open Access Journals (Sweden)

    Toshiyuki Obikawa

    2017-05-01

    Full Text Available Single point incremental forming is used for rapid prototyping of sheet metal parts. This forming technology was applied to the fabrication of thin shell micropyramids of aluminum, stainless steel, and titanium foils. A single point tool used had a tip radius of 0.1 mm or 0.01 mm. An ultrasonic spindle with axial vibration was implemented for improving the shape accuracy of micropyramids formed on 5–12 micrometers-thick aluminum, stainless steel, and titanium foils. The formability was also investigated by comparing the forming limits of micropyramids of aluminum foil formed with and without ultrasonic vibration. The shapes of pyramids incrementally formed were truncated pyramids, twisted pyramids, stepwise pyramids, and star pyramids about 1 mm in size. A much smaller truncated pyramid was formed only for titanium foil for qualitative investigation of the size reduction on forming accuracy. It was found that the ultrasonic vibration improved the shape accuracy of the formed pyramids. In addition, laser heating increased the forming limit of aluminum foil and it is more effective when both the ultrasonic vibration and laser heating are applied.

  17. Spectroscopic Measurements of Planar Foil Plasmas Driven by a MA LTD

    Science.gov (United States)

    Patel, Sonal; Yager-Elorriaga, David; Steiner, Adam; Jordan, Nick; Gilgenbach, Ronald; Lau, Y. Y.

    2014-10-01

    Planar foil ablation experiments are being conducted on the Linear Transformer Driver (LTD) at the University of Michigan. The experiment consists of a 400 nm-thick, Al planar foil and a current return post. An optical fiber is placed perpendicular to the magnetic field and linear polarizers are used to isolate the pi and sigma lines. The LTD is charged to +/-70 kV with approximately 400-500 kA passing through the foil. Laser shadowgraphy has previously imaged the plasma and measured anisotropy in the Magneto Rayleigh-Taylor (MRT) instability. Localized magnetic field measurements using Zeeman splitting during the current rise is expected to yield some insight into this anisotropy. Initial experiments use Na D lines of Al foils seeded with sodium to measure Zeeman splitting. Several ion lines are also currently being studied, such as Al III and C IV, to probe the higher temperature core plasma. In planned experiments, several lens-coupled optical fibers will be placed across the foil, and local magnetic field measurements will be taken to measure current division within the plasma. This work was supported by US DoE. S.G. Patel and A.M. Steiner supported by NPSC funded by Sandia. D.A. Yager supported by NSF fellowship Grant DGE 1256260.

  18. Aluminium foil as an alternative substrate for the spectroscopic interrogation of endometrial cancer.

    Science.gov (United States)

    Paraskevaidi, Maria; Morais, Camilo L M; Raglan, Olivia; Lima, Kássio M G; Paraskevaidis, Evangelos; Martin-Hirsch, Pierre L; Kyrgiou, Maria; Martin, Francis L

    2018-03-07

    Biospectroscopy has the potential to investigate and characterise biological samples and could, therefore, be utilised to diagnose various diseases in a clinical environment. An important consideration in spectrochemical studies is the cost-effectiveness of the substrate used to support the sample, as high expense would limit their translation into clinic. In this paper, the performance of low-cost aluminium (Al) foil substrates was compared with the commonly used low-emissivity (low-E) slides. Attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy was used to analyse blood plasma and serum samples from women with endometrial cancer and healthy controls. The two populations were differentiated using principal component analysis with support vector machines (PCA-SVM) with 100% sensitivity in plasma samples (endometrial cancer=70; healthy controls=15) using both Al foil and low-E slides as substrates. The same sensitivity results (100%) were achieved for serum samples (endometrial cancer=60; healthy controls=15). Specificity was found higher using Al foil (90%) in comparison to low-E slides (85%) and lower using Al foil (70%) in comparison to low-E slides in serum samples. The establishment of Al foil as low-cost and highly-performing substrate would pave the way for large-scale, multi-centre studies and potentially for routine clinical use. This article is protected by copyright. All rights reserved.

  19. A New Analysis Tool Assessment for Rotordynamic Modeling of Gas Foil Bearings

    Science.gov (United States)

    Howard, Samuel A.; SanAndres, Luis

    2010-01-01

    Gas foil bearings offer several advantages over traditional bearing types that make them attractive for use in high-speed turbomachinery. They can operate at very high temperatures, require no lubrication supply (oil pumps, seals, etc.), exhibit very long life with no maintenance, and once operating airborne, have very low power loss. The use of gas foil bearings in high-speed turbomachinery has been accelerating in recent years, although the pace has been slow. One of the contributing factors to the slow growth has been a lack of analysis tools, benchmarked to measurements, to predict gas foil bearing behavior in rotating machinery. To address this shortcoming, NASA Glenn Research Center (GRC) has supported the development of analytical tools to predict gas foil bearing performance. One of the codes has the capability to predict rotordynamic coefficients, power loss, film thickness, structural deformation, and more. The current paper presents an assessment of the predictive capability of the code, named XLGFBTH (Texas A&M University). A test rig at GRC is used as a simulated case study to compare rotordynamic analysis using output from the code to actual rotor response as measured in the test rig. The test rig rotor is supported on two gas foil journal bearings manufactured at GRC, with all pertinent geometry disclosed. The resulting comparison shows that the rotordynamic coefficients calculated using XLGFBTH represent the dynamics of the system reasonably well, especially as they pertain to predicting critical speeds.

  20. Surface structure deduced differences of copper foil and film for graphene CVD growth

    International Nuclear Information System (INIS)

    Tian, Junjun; Hu, Baoshan; Wei, Zidong; Jin, Yan; Luo, Zhengtang; Xia, Meirong; Pan, Qingjiang; Liu, Yunling

    2014-01-01

    Highlights: • We demonstrate the significant differences between Cu foil and film in the surface morphology and crystal orientation distribution. • The different surface structure leads to the distinctive influences of the CH 4 and H 2 concentrations on the thickness and quality of as-grown graphene. • Nucleation densities and growth rate differences at the initial growth stages on the Cu foil and film were investigated and discussed. - Abstract: Graphene was synthesized on Cu foil and film by atmospheric pressure chemical vapor deposition (CVD) with CH 4 as carbon source. Electron backscattered scattering diffraction (EBSD) characterization demonstrates that the Cu foil surface after the H 2 -assisted pre-annealing was almost composed of Cu(1 0 0) crystal facet with larger grain size of ∼100 μm; meanwhile, the Cu film surface involved a variety of crystal facets of Cu(1 1 1), Cu(1 0 0), and Cu(1 1 0), with the relatively small grain size of ∼10 μm. The different surface structure led to the distinctive influences of the CH 4 and H 2 concentrations on the thickness and quality of as-grown graphene. Further data demonstrate that the Cu foil enabled more nucleation densities and faster growth rates at the initial growth stages than the Cu film. Our results are beneficial for understanding the relationship between the metal surface structure and graphene CVD growth

  1. The Chevron Foil Thrust Bearing: Improved Performance Through Passive Thermal Management and Effective Lubricant Mixing

    Science.gov (United States)

    Bruckner, Robert

    2013-01-01

    An improved foil thrust bearing is described that eliminates or reduces the need for forced cooling of the bearing foils while at the same time improves the load capacity of the bearing, enhances damping, provides overload tolerance, and eliminates the high speed load capacity drop-off that plagues the current state of the art. The performance improvement demonstrated by the chevron foil thrust bearing stems from a novel trailing edge shape that splays the hot lubricant in the thin film radially, thus preventing hot lubricant carry-over into the ensuing bearing sector. Additionally, the chevron shaped trailing edge induces vortical mixing of the hot lubricant with the gas that is naturally resident within the inter-pad region of a foil thrust bearing. The elimination of hot gas carry-over in combination with the enhanced mixing has enabled a completely passive thermally managed foil bearing design. Laboratory testing at NASA has confirmed the original analysis and reduced this concept to practice.

  2. Simultaneous schlieren photography and soot foil in the study of detonation phenomena

    Science.gov (United States)

    Kellenberger, Mark; Ciccarelli, Gaby

    2017-10-01

    The use of schlieren photography has been essential in unravelling the complex nature of high-speed combustion phenomena, but its line-of-sight integration makes it difficult to decisively determine the nature of multi-dimensional combustion wave propagation. Conventional schlieren alone makes it impossible to determine in what plane across the channel an observed structure may exist. To overcome this, a technique of simultaneous high-speed schlieren photography and soot foils was demonstrated that can be applied to the study of detonation phenomena. Using a kerosene lamp, soot was deposited on a glass substrate resulting in a semi-transparent sheet through which schlieren source light could pass. In order to demonstrate the technique, experiments were carried out in mixtures of stoichiometric hydrogen-oxygen at initial pressures between 10 and 15 kPa. Compared to schlieren imaging obtained without a sooted foil, high-speed video results show schlieren images with a small reduction of contrast with density gradients remaining clear. Areas of high temperature cause soot lofted from the foil to incandescence strongly, resulting in the ability to track hot spots and flame location. Post-processing adjustments were demonstrated to make up for camera sensitivity limitations to enable viewing of schlieren density gradients. High-resolution glass soot foils were produced that enable direct coupling of schlieren video to triple-point trajectories seen on the soot foils, allowing for the study of three-dimensional propagation mechanisms of detonation waves.

  3. Ultrathin foils used for low-energy neutral atom imaging of the terrestrial magnetosphere

    Science.gov (United States)

    Funsten, Herbert O.; McComas, David J.; Barraclough, Bruce L.

    1993-12-01

    Magnetospheric imaging by remote detection of low-energy neutral atoms (LENAs) that are created by charge exchange between magnetospheric plasma ions and neutral geocoronal atoms has been proposed as a method to provide global information of magnetospheric dynamics. For LENA detection, carbon foils can be implemented to (1) ionize the LENAs and electrostatically remove them from the large background of solar UV scattered by the geocorona and (2) generate secondary electrons to provide coincidence and/or LENA trajectory information. Quantification of LENA-foil interactions are crucial in defining LENA imager performance. We present equilibrium charge state and angular scatter distributions for 1 to 30-keV atomic hydrogen, helium, and oxygen transiting nominal 0.5 (mu) g cm-2 carbon foils. Results obtained after coating the exit surface of foils with either aluminum or gold suggest that the intended alteration of the exit surface chemistry has no effect on the charge state distributions due to foil contamination from exposure to air.

  4. Diffusion of liquid uranium into solid tantalum foils up to 1350C

    Energy Technology Data Exchange (ETDEWEB)

    Kuznietz, M.; Livne, Z.; Cotler, C.

    1986-01-01

    The diffusion of liquid uranium into solid foils, 0.3 mm thick, was investigated in the temperature range 1160-1350C, for reaction times up to 20 h. The tantalum foils were immersed in liquid uranium contained in zirconia crucibles. Uranium was found to cover the tantalum foils and climb upwards in amounts rising with reaction time and temperature. A scanning electron microscope study with microanalysis by EDAX revealed a multilayer structure. On the tantalum-foil surfaces, exposed to liquid uranium, layers form progressively inwards, under the outer uranium layers, in the following sequence: a uranium-tantalum layer (with a U:Ta ratio between 40:60 and 60:40) forms at 1160 C and 1185 C, and disappears completely at 1255 C; a columnar tantalum layer (containing <1W/O U); an inner uranium layer (at 1210 C and above); an inner tantalum-grain layer with uranium along grain boundaries (above 1210 C). The growth of the recrystallized columnar tantalum layer is related to the penetration of uranium as liquid into the solid tantalum foil. Cracks in this layer at 1300 C and above cause tears and failures in the tantalum.

  5. An Oil-Free Thrust Foil Bearing Facility Design, Calibration, and Operation

    Science.gov (United States)

    Bauman, Steve

    2005-01-01

    New testing capabilities are needed in order to foster thrust foil air bearing technology development and aid its transition into future Oil-Free gas turbines. This paper describes a new test apparatus capable of testing thrust foil air bearings up to 100 mm in diameter at speeds to 80,000 rpm and temperatures to 650 C (1200 F). Measured parameters include bearing torque, load capacity, and bearing temperatures. This data will be used for design performance evaluations and for validation of foil bearing models. Preliminary test results demonstrate that the rig is capable of testing thrust foil air bearings under a wide range of conditions which are anticipated in future Oil-Free gas turbines. Torque as a function of speed and temperature corroborates results expected from rudimentary performance models. A number of bearings were intentionally failed with no resultant damage whatsoever to the test rig. Several test conditions (specific speeds and loads) revealed undesirable axial shaft vibrations which have been attributed to the magnetic bearing control system and are under study. Based upon these preliminary results, this test rig will be a valuable tool for thrust foil bearing research, parametric studies and technology development.

  6. UV Ink-Jet printability and durability of stone and foil

    Directory of Open Access Journals (Sweden)

    Tadeja Muck

    2014-07-01

    Full Text Available he use of ultraviolet (UV printing technology has impacted printing industry in last years due to its applicability on many different »absorptive« as well as »non-absorptive« printing materials. The printability of building materials and recycled foils is relatively unknown. For primary building materials like stones, functionality can be explored with the use of UV printing technology; increased visual, informative effect or even “creative printing” of buildings. Also several aspects of recycled foils reusability as a printing material could be find (printed packaging material or also like secondary building materials. In the present study, printability of the stone and recycled foil and durability of UV prints was explored by means of macroscopically and microscopically characterization. Results indicate that higher print quality can be achieved on polished stone and on coated foil, which surfaces have higher smoothness. Durability of UV prints at freezing is higher at unpolished stone and coated foil that is at materials with the higher surface energy.

  7. Experiments on helical modes in magnetized thin foil-plasmas

    Science.gov (United States)

    Yager-Elorriaga, David

    2017-10-01

    This paper gives an in-depth experimental study of helical features on magnetized, ultrathin foil-plasmas driven by the 1-MA linear transformer driver at University of Michigan. Three types of cylindrical liner loads were designed to produce: (a) pure magneto-hydrodynamic (MHD) modes (defined as being void of the acceleration-driven magneto-Rayleigh-Taylor instability, MRT) using a non-imploding geometry, (b) pure kink modes using a non-imploding, kink-seeded geometry, and (c) MRT-MHD coupled modes in an unseeded, imploding geometry. For each configuration, we applied relatively small axial magnetic fields of Bz = 0.2-2.0 T (compared to peak azimuthal fields of 30-40 T). The resulting liner-plasmas and instabilities were imaged using 12-frame laser shadowgraphy and visible self-emission on a fast framing camera. The azimuthal mode number was carefully identified with a tracking algorithm of self-emission minima. Our experiments show that the helical structures are a manifestation of discrete eigenmodes. The pitch angle of the helix is simply m / kR , from implosion to explosion, where m, k, and R are the azimuthal mode number, axial wavenumber, and radius of the helical instability. Thus, the pitch angle increases (decreases) during implosion (explosion) as R becomes smaller (larger). We found that there are one, or at most two, discrete helical modes that arise for magnetized liners, with no apparent threshold on the applied Bz for the appearance of helical modes; increasing the axial magnetic field from zero to 0.5 T changes the relative weight between the m = 0 and m = 1 modes. Further increasing the applied axial magnetic fields yield higher m modes. Finally, the seeded kink instability overwhelms the intrinsic instability modes of the plasma. These results are corroborated with our analytic theory on the effects of radial acceleration on the classical sausage, kink, and higher m modes. Work supported by US DOE award DE-SC0012328, Sandia National Laboratories

  8. [A case of occlusal support reconstruction with modification of occlusal plane by fixed prosthetic restoration including dental implant].

    Science.gov (United States)

    Moriwaki, Yoshihiro

    2006-04-01

    A 54-year-old female patient visited our dental office July 1997. The patient's chief complaint was difficulty of chewing due to loss of the right mandibular molars. She had a collapsed occlusal plane with loss extended over a long period of time. This case report describes restoration of the occlusal plane and occlusal supporting area by fixed prosthesis including implant-supported crowns. Anterior guidance and provisional restoration are useful for reconstruction of the occlusal plane. In a dental arch with implant-supported and tooth-supported crowns, periodical dental checkup and occlusal equilibration are very important due to the existence of biomechanically different factors. The patient was very satisfied with the fixed prosthesis including implant-supported crowns. It is thought that implant treatment improves the quality of life of free-end partially edentulous patients.

  9. Influence of the quality of the finished occlusion on postretention occlusal relapse.

    Science.gov (United States)

    de Freitas, Karina Maria Salvatore; Janson, Guilherme; de Freitas, Marcos Roberto; Pinzan, Arnaldo; Henriques, José Fernando Castanha; Pinzan-Vercelino, Célia Regina Maio

    2007-10-01

    In this study, we aimed to evaluate the influence of the quality of the finished occlusion on postretention occlusal stability. The sample comprised 87 patients with Class I malocclusion, treated with extraction of the 4 first premolars and edgewise mechanics; they were divided into 2 groups, according to the quality of their finished occlusions. Group 1 included 44 subjects (23 boys, 21 girls) with posttreatment peer assessment rating (PAR) scores from 0 to 5. The mean pretreatment age was 13.74 years (SD 2.14). The mean treatment time was 1.92 years (SD 0.57), the mean retention time was 1.75 years (SD 0.96), and the mean time of posttreatment evaluation was 5.17 years (SD 1.82). Group 2 included 43 subjects (22 boys, 21 girls) with posttreatment PAR scores greater than 5. The mean initial age was 13.34 years (SD 1.35). The mean treatment time was 2.20 years (SD 0.66), the mean retention time was 1.77 years (SD 0.78), and the mean posttreatment evaluation was 5.47 years (SD 1.60). The PAR and the Little irregularity indexes were measured on the dental casts at pretreatment, posttreatment, and postretention. Intergroup comparisons were made with independent t tests, and the Pearson correlation coefficient was applied to the PAR score for the whole sample at the times evaluated. Well-finished patients had lower posttreatment and postretention PAR scores and greater changes during the treatment and posttreatment periods than did the poorly finished patients. For the Little irregularity index, the only difference between the groups was at the posttreatment stage; group 1 had a smaller irregularity score than group 2. The correlation coefficients showed that the greater the treatment changes, the smaller the posttreatment PAR score and the greater the relapse. But the higher the posttreatment PAR score, the higher the postretention PAR score. It was concluded that the greater the quality of the orthodontic finished occlusion, the greater are the treatment changes and

  10. Induction of subterahertz surface waves on a metal wire by intense laser interaction with a foil

    Science.gov (United States)

    Teramoto, Kensuke; Inoue, Shunsuke; Tokita, Shigeki; Yasuhara, Ryo; Nakamiya, Yoshihide; Nagashima, Takeshi; Mori, Kazuaki; Hashida, Masaki; Sakabe, Shuji

    2018-02-01

    We have demonstrated that a pulsed electromagnetic wave (Sommerfeld wave) of subterahertz frequency and 11-MV/m field strength can be induced on a metal wire by the interaction of an intense femtosecond laser pule with an adjacent metal foil at a laser intensity of 8.5 × 1018W /c m2 . The polarity of the electric field of this surface wave is opposite to that obtained by the direct interaction of the laser with the wire. Numerical simulations suggest that an electromagnetic wave associated with electron emission from the foil induces the surface wave. A tungsten wire is placed normal to an aluminum foil with a gap so that the wire is not irradiated and damaged by the laser pulse, thus making it possible to generate surface waves on the wire repeatedly.

  11. The Synthesis of Highly Aligned Cupric Oxide Nanowires by Heating Copper Foil

    Directory of Open Access Journals (Sweden)

    Jianbo Liang

    2011-01-01

    Full Text Available We have investigated the effects of grain size and orientation of copper substrates for the growth of cupric oxide nanowires by thermal oxidation method. Long, less-roughness, high-density, and aligned cupric oxide nanowires have been synthesized by heating (200 oriented copper foils with small grain size in air gas. Long and aligned nanowires of diameter around 80 nm can only be formed within a short temperature range from 400 to 700°C. On the other hand, uniform, smooth-surface, and aligned nanowires were not formed in the case of larger crystallite size of copper foils with (111 and (200 orientation. Smaller grain size of copper foil with (200 orientation is favorable for the growth of highly aligned, smooth surface, and larger-diameter nanowires by thermal oxidation method.

  12. Experimental study on mass transfer of contaminants through an enthalpy recovery unit with polymer membrane foils

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei

    2014-01-01

    Laboratory experimental studies were conducted to investigate the mass transfer of contaminants through a total heat recovery unit with polymer membranes foils. The studies were conducted in twin climate chambers which simulated outdoor and indoor thermal climates. One manufacturd total heat...... recovery unit with polymer membrane foils was used as refeering unit in this study. The experiments were conducted with different outdoor thermal climates e.g. warm-humid and cold-dry climates; isothermal and non isothermal as well as equal humidity and non equal humidity with indoor climate. Three...... membrane or due to both reasons. The results indicated that polymer membrane foils may be a choice for producing total heat recovering equipment in ventilation systems....

  13. A new flexible titanium foil cell for hydrothermal experiments and fluid sampling.

    Science.gov (United States)

    Wu, Shi-Jun; Cai, Min-Jian; Yang, Can-Jun; Li, Ke-Wei

    2016-09-01

    This paper describes the design of a flexible titanium foil cell, as well as its applications in hydrothermal experiments and in non-contaminating storage of seafloor hydrothermal fluids. A flexible cell constructed totally from pure titanium (Grade 1) can be used in corrosive environment because of the excellent chemical stability and temperature tolerance of the material. Theoretical calculation and finite element analysis of the titanium foil cell have been conducted to identify its flexibility and deformation mode. Two applications, i.e., hydrothermal reaction and non-contaminating fluid sampling, were introduced subsequently. The flexible titanium foil cell was successfully tested at elevated temperature and pressure of up to 400 °C and 40 MPa, respectively, demonstrating that it could be widely used under supercritical water conditions.

  14. Applications of beam-foil spectroscopy to atomic collisions in solids

    Science.gov (United States)

    Sellin, I. A.

    1976-01-01

    Some selected papers presented at the Fourth International Conference on Beam-Foil Spectroscopy, whose results are of particular pertinence to ionic collision phenomena in solids, are reviewed. The topics discussed include solid target effects and means of surmounting them in the measurement of excited projectile ion lifetimes for low-energy heavy element ions; the electron emission accompanying the passage of heavy particles through solid targets; the collision broadening of X rays emitted from 100 keV ions moving in solids; residual K-shell excitation in chlorine ions penetrating carbon; comparison between 40 MeV Si on gaseous SiH4 targets at 300 mtorr and 40 MeV Si on Al; and the emergent surface interaction in beam-foil spectroscopy. A distinct overlap of interests between the sciences of beam-foil spectroscopy and atomic collisions in solids is pointed out.

  15. Resonance effects of transition radiation emitted from thin foil stacks using electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Awata, Takaaki; Yajima, Kazuaki; Tanaka, Takashi [Kyoto Univ. (Japan). Faculty of Engineering] [and others

    1997-03-01

    Transition Radiation(TR) X rays are expected to be a high brilliant X-ray source because the interference among TR X rays emitted from many thin foils placed periodically in vacuum can increase their intensity and make them quasi-monochromatic. In order to study the interference (resonance) effects of TR, we measured the energy spectra of TR for several sets of thin-foil stacks at various emission angles. It was found that the resonance effects of TR are classified into intrafoil and interfoil resonances and the intensity of TR X rays increases nonlinearly with increasing foil number, attributing to the interfoil resonance. It became evident that the brilliance of TR is as high as that of SR. (author)

  16. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan

    1992-01-01

    Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...... in a test quadrant of the telescope structure and from ASTRO-D foils held in a simple fixture. The X-ray data is compared with laser data and other surface structure data such as STM, atomic force microscopy (AFM), TEM, and electron micrography. The data obtained at Cu K-alpha(1), (8.05 keV) from all...

  17. Bright betatronlike x rays from radiation pressure acceleration of a mass-limited foil target.

    Science.gov (United States)

    Yu, Tong-Pu; Pukhov, Alexander; Sheng, Zheng-Ming; Liu, Feng; Shvets, Gennady

    2013-01-25

    By using multidimensional particle-in-cell simulations, we study the electromagnetic emission from radiation pressure acceleration of ultrathin mass-limited foils. When a circularly polarized laser pulse irradiates the foil, the laser radiation pressure pushes the foil forward as a whole. The outer wings of the pulse continue to propagate and act as a natural undulator. Electrons move together with ions longitudinally but oscillate around the latter transversely, forming a self-organized helical electron bunch. When the electron oscillation frequency coincides with the laser frequency as witnessed by the electron, betatronlike resonance occurs. The emitted x rays by the resonant electrons have high brightness, short durations, and broad band ranges which may have diverse applications.

  18. Determination of neutron flux with an arbitrary energy distribution by measurement of irradiated foils activity

    International Nuclear Information System (INIS)

    Ljubenov, V.; Milosevic, M.

    2003-01-01

    A procedure for the neutron flux determination in a neutron field with an arbitrary energy spectrum, based on the using of standard methods for the measurement of irradiated foils activity and on the application of the SCALE-4.4a code system for averaged cross section calculation is described in this paper. Proposed procedure allows to include the energy spectrum of neutron flux reestablished in the location of irradiated foils and the resonance self-shielding effects in the foils also. Example application of this procedure is given for the neutron flux determination inside the neutron filter with boron placed in the centre of heavy water critical assembly RB at the Vinca Institute (author)

  19. Radon-thoron discrimination using a polythene foil: an application in uranium exploration

    International Nuclear Information System (INIS)

    Ramola, R.C.; Singh, M.; Sandhu, A.S.; Singh, S.; Virk, H.S.

    1989-01-01

    Integrated measurements of radon concentrations in subsurface soil are being used extensively for uranium exploration and earthquake prediction. For uranium exploration only the radon signals are needed; however, a part of the α-activity may derive from thoron. To exclude thoron, a polythene foil has been used as an anti-thoron membrane to delay the entry of thoron into the detector system so that only the longer lived isotope 222 Rn survives to be measured. A long term integrated measurement has been carried out using LR-115 and CR-39 plastic track detectors. The observed track density has been determined as a function of foil thickness. It is found that a polythene foil of appropriate thickness could be successfully employed for the separation of radon and thoron in soil. (author)

  20. Molecular beam epitaxy of single crystalline GaN nanowires on a flexible Ti foil

    Science.gov (United States)

    Calabrese, Gabriele; Corfdir, Pierre; Gao, Guanhui; Pfüller, Carsten; Trampert, Achim; Brandt, Oliver; Geelhaar, Lutz; Fernández-Garrido, Sergio

    2016-05-01

    We demonstrate the self-assembled growth of vertically aligned GaN nanowire ensembles on a flexible Ti foil by plasma-assisted molecular beam epitaxy. The analysis of single nanowires by transmission electron microscopy reveals that they are single crystalline. Low-temperature photoluminescence spectroscopy demonstrates that in comparison to standard GaN nanowires grown on Si, the nanowires prepared on the Ti foil exhibit an equivalent crystalline perfection, a higher density of basal-plane stacking faults, but a reduced density of inversion domain boundaries. The room-temperature photoluminescence spectrum of the nanowire ensemble is not influenced or degraded by the bending of the substrate. The present results pave the way for the fabrication of flexible optoelectronic devices based on GaN nanowires on metal foils.

  1. Molecular beam epitaxy of single crystalline GaN nanowires on a flexible Ti foil

    International Nuclear Information System (INIS)

    Calabrese, Gabriele; Corfdir, Pierre; Gao, Guanhui; Pfüller, Carsten; Trampert, Achim; Brandt, Oliver; Geelhaar, Lutz; Fernández-Garrido, Sergio

    2016-01-01

    We demonstrate the self-assembled growth of vertically aligned GaN nanowire ensembles on a flexible Ti foil by plasma-assisted molecular beam epitaxy. The analysis of single nanowires by transmission electron microscopy reveals that they are single crystalline. Low-temperature photoluminescence spectroscopy demonstrates that in comparison to standard GaN nanowires grown on Si, the nanowires prepared on the Ti foil exhibit an equivalent crystalline perfection, a higher density of basal-plane stacking faults, but a reduced density of inversion domain boundaries. The room-temperature photoluminescence spectrum of the nanowire ensemble is not influenced or degraded by the bending of the substrate. The present results pave the way for the fabrication of flexible optoelectronic devices based on GaN nanowires on metal foils.

  2. Slowing down of 100 keV antiprotons in Al foils

    Science.gov (United States)

    Nordlund, K.

    2018-03-01

    Using energy degrading foils to slow down antiprotons is of interest for producing antihydrogen atoms. I consider here the slowing down of 100 keV antiprotons, that will be produced in the ELENA storage ring under construction at CERN, to energies below 10 keV. At these low energies, they are suitable for efficient antihydrogen production. I simulate the antihydrogen motion and slowing down in Al foils using a recently developed molecular dynamics approach. The results show that the optimal Al foil thickness for slowing down the antiprotons to below 5 keV is 910 nm, and to below 10 keV is 840 nm. Also the lateral spreading of the transmitted antiprotons is reported and the uncertainties discussed.

  3. The Anomalous Currents In The Front Foils of the JET Lost Alpha Diagnostic KA-2

    Energy Technology Data Exchange (ETDEWEB)

    Cecil, F. E.; Kiptily, V.; Salmi, A.; Horton, A.; Fullard, K.; Murari, A.; Darrow, D.; Hill, K.

    2011-05-04

    We have examined the observed currents in the front foils of the JET Faraday cup lost alpha particle diagnostic KA-2. In particular, we have sought to understand the currents during Ohmic plasmas for which the ion flux at the detectors was initially assumed to be negligible. We have considered two sources of this current: plasma ions both deuterium and impurity in the vicinity of the detector including charge exchange neutrals and photoemission from scattered UV radiation. Based upon modeling and empirical observation, the latter source appears most likely and, moreover, seems to be applicable to the currents in the front foil during ELMy H-mode plasmas. A very thin gold or nickel foil attached to the present detector aperture is proposed as a solution to this problem, and realistic calculations of expected fluxes of lost energetic neutral beam ions during TF ripple experiments are presented as justification of this proposed solution.

  4. The development of uranium foil farication technology utilizing twin roll method for Mo-99 irradiation target

    CERN Document Server

    Kim, C K; Park, H D

    2002-01-01

    MDS Nordion in Canada, occupying about 75% of global supply of Mo-99 isotope, has provided the irradiation target of Mo-99 using the rod-type UAl sub x alloys with HEU(High Enrichment Uranium). ANL (Argonne National Laboratory) through co-operation with BATAN in Indonesia, leading RERTR (Reduced Enrichment for Research and Test Reactors) program substantially for nuclear non-proliferation, has designed and fabricated the annular cylinder of uranium targets, and successfully performed irradiation test, in order to develop the fabrication technology of fission Mo-99 using LEU(Low Enrichment Uranium). As the uranium foils could be fabricated in laboratory scale, not in commercialized scale by hot rolling method due to significant problems in foil quality, productivity and economic efficiency, attention has shifted to the development of new technology. Under these circumstances, the invention of uranium foil fabrication technology utilizing twin-roll casting method in KAERI is found to be able to fabricate LEU or...

  5. Identification of Impact Craters in Foils from the Stardust Interstellar Dust Collector

    Science.gov (United States)

    Stroud, R. M.; Allen, C.; Bajt, S.; Bechtel, H. A.; Borg, J.; Brenker, F.; Bridges, J.; Brownlee, D. E.; Burchell, M.; Burghammer, M.; hide

    2011-01-01

    The Stardust Interstellar Dust Collection tray provides the first opportunity for the direct laboratory-based measurement of contemporary interstellar dust. The total exposed surface of the tray was approximately 0.1 square meters, including 153 square centimeters of Al foil in addition to the silica aerogel tiles that are the primary collection medium. Preliminary examination of aerogel tiles has already revealed 16 tracks from particle impacts with an orientation consistent with an interstellar origin, and to date four of the particles associated with these tracks have a composition consistent with an extraterrestrial origin. Tentative identification of impact craters on three foil samples was also reported previously. Here we present the definitive identification of 20 impact craters on five foils.

  6. Modelling the deformation of nickel foil during manufacturing of nanostructures on injection moulding tool inserts

    DEFF Research Database (Denmark)

    Sonne, Mads Rostgaard; Cech, Jiri; Pranov, H.

    2016-01-01

    In the present work, a manufacturing process for transferring nanostructures from a glass wafer, to a double-curvedinsert for injection moulding is demonstrated. A nanostructure consisting of sinusoidal cross-gratings with a period of 426 nm issuccessfully transferred to hemispheres on an aluminium...... substrate with three different radii; 500 μm, 1000 μm and 2000 μm,respectively. The nanoimprint is performed using a 50 μm thick nickel foil, manufactured using electroforming. During theimprinting process, the nickel foil is stretched due to the curved surface of the aluminium substrate. Experimentally......, it is possibleto address this stretch by counting the periods of the cross-gratings via SEM characterization. A model for the deformation of thenickel foil during nanoimprint is developed, utilizing non-linear material and geometrical behaviour. Good agreement betweenmeasured and numerically calculated stretch...

  7. 2-D numerical study of the hydrodynamics of laser accelerated foils

    International Nuclear Information System (INIS)

    Atzeni, S.

    1989-01-01

    The large scale hydrodynamics of laser accelerated thin disks (foils) are studied numerically using a 2-D, evolutionary Lagrangian fluid code. The laser and target parameters considered are relevant to direct drive laser fusion, in the classical interaction regime. Peculiar 2-D features observed in the experiments are recovered in the simulations; agreement with experimental data is found for a series of experiments concerning foils of different thickness. Scaling laws for the design of hydrodynamically equivalent experiments are tested, with the effects of non-scaled processes turning out to be fairly small, although observable, and qualitatively in agreement with the relevant theory. Simulations also indicate the adequacy of foil acceleration experiments driven by non-uniform (but controlled) beams to the quantitative study of the smoothing of the irradiation non-uniformities. (author)

  8. Determination of low-energy ion-induced electron yields from thin carbon foils

    International Nuclear Information System (INIS)

    Allegrini, Frederic; Wimmer-Schweingruber, Robert F.; Wurz, Peter; Bochsler, Peter

    2003-01-01

    Ion beams crossing thin carbon foils can cause electron emission from the entrance and exit surface. Thin carbon foils are used in various types of time-of-flight (TOF) mass spectrometers to produce start pulses for TOF measurements. The yield of emitted electrons depends, among other parameters, on the energy of the incoming ion and its mass, and it has been experimentally determined for a few projectile elements. The electron emission yield is of great importance for deriving abundance ratios of elements and isotopes in space plasmas using TOF mass spectrometers. We have developed a detector for measuring ion-induced electron yields, and we have extended the electron yield measurements for oxygen to energies relevant for solar wind research. We also present first measurements of the carbon foil electron emission yield for argon and iron in the solar wind energy range

  9. Local deposition of Copper on Aluminum based MWT Back Contact Foil using Cold Spray Technology

    Energy Technology Data Exchange (ETDEWEB)

    Goris, M.J.A.A.; Bennett, I.J.; Eerenstein, W. [ECN Solar Energy, Petten (Netherlands)

    2013-11-15

    MWT cell and module technology has been shown to result in modules with up to 5% higher power output than H-pattern modules and to be suitable for use with thin and fragile cells. In this study, the use of a low cost conductive back-sheet with aluminium as the current carrier in combination with locally applied copper (5 to 30 {mu}m) using the cold spray method is benchmarked against a standard PVF-PET-copper foil in 2 x 2 cell modules. Cell to module losses and reliability during climate chamber tests according to IEC61215 ed. 2, are comparable to module made with the standard foil. Optimizing the cold spray process can result in a cost reduction of more than a factor 10 of the current carrying component, when compared to a full copper conductive back-sheet foil.

  10. Modeling self-occlusions in dynamic shape and appearance tracking

    KAUST Repository

    Yang, Yanchao

    2013-12-01

    We present a method to track the precise shape of a dynamic object in video. Joint dynamic shape and appearance models, in which a template of the object is propagated to match the object shape and radiance in the next frame, are advantageous over methods employing global image statistics in cases of complex object radiance and cluttered background. In cases of complex 3D object motion and relative viewpoint change, self-occlusions and disocclusions of the object are prominent, and current methods employing joint shape and appearance models are unable to accurately adapt to new shape and appearance information, leading to inaccurate shape detection. In this work, we model self-occlusions and dis-occlusions in a joint shape and appearance tracking framework. Experiments on video exhibiting occlusion/dis-occlusion, complex radiance and background show that occlusion/dis-occlusion modeling leads to superior shape accuracy compared to recent methods employing joint shape/appearance models or employing global statistics. © 2013 IEEE.

  11. Object tracking by occlusion detection via structured sparse learning

    KAUST Repository

    Zhang, Tianzhu

    2013-06-01

    Sparse representation based methods have recently drawn much attention in visual tracking due to good performance against illumination variation and occlusion. They assume the errors caused by image variations can be modeled as pixel-wise sparse. However, in many practical scenarios these errors are not truly pixel-wise sparse but rather sparsely distributed in a structured way. In fact, pixels in error constitute contiguous regions within the object\\'s track. This is the case when significant occlusion occurs. To accommodate for non-sparse occlusion in a given frame, we assume that occlusion detected in previous frames can be propagated to the current one. This propagated information determines which pixels will contribute to the sparse representation of the current track. In other words, pixels that were detected as part of an occlusion in the previous frame will be removed from the target representation process. As such, this paper proposes a novel tracking algorithm that models and detects occlusion through structured sparse learning. We test our tracker on challenging benchmark sequences, such as sports videos, which involve heavy occlusion, drastic illumination changes, and large pose variations. Experimental results show that our tracker consistently outperforms the state-of-the-art. © 2013 IEEE.

  12. Occlusion detection via structured sparse learning for robust object tracking

    KAUST Repository

    Zhang, Tianzhu

    2014-01-01

    Sparse representation based methods have recently drawn much attention in visual tracking due to good performance against illumination variation and occlusion. They assume the errors caused by image variations can be modeled as pixel-wise sparse. However, in many practical scenarios, these errors are not truly pixel-wise sparse but rather sparsely distributed in a structured way. In fact, pixels in error constitute contiguous regions within the object’s track. This is the case when significant occlusion occurs. To accommodate for nonsparse occlusion in a given frame, we assume that occlusion detected in previous frames can be propagated to the current one. This propagated information determines which pixels will contribute to the sparse representation of the current track. In other words, pixels that were detected as part of an occlusion in the previous frame will be removed from the target representation process. As such, this paper proposes a novel tracking algorithm that models and detects occlusion through structured sparse learning. We test our tracker on challenging benchmark sequences, such as sports videos, which involve heavy occlusion, drastic illumination changes, and large pose variations. Extensive experimental results show that our proposed tracker consistently outperforms the state-of-the-art trackers.

  13. Measurements of activation products associated with Havar foils from a GE PETtrace medical cyclotron using high resolution gamma spectroscopy.

    Science.gov (United States)

    Manickam, Vivek; Brey, Richard R; Jenkins, Peter A; Christian, Paul E

    2009-02-01

    Havar foils are specially engineered for beam-line windows used in the General Electric (GE) PETtrace medical cyclotron that can withstand the high pressure differentials and also temperatures developed near the target with proton bombardment. These foils effectively separate components along the beam line of the cyclotron. Various activation products are produced in the foils from the primary proton beam and other secondary radiations. An accurate estimate of the activation products is necessary for the disposal of these foils. The foils were assayed using two High Purity Germanium (HPGe) detectors calibrated over a wide energy range. These were positioned at different distances (0.10 m, 0.24 m, and 1.74 m) away from the detector faces to accommodate their high activities. A summary of the anticipated relative abundance of each activation product and a scatter plot of the average exposure rate per unit charge incident on the foil vs. time post-activation are provided. A detailed spectral analysis of the foils in the energy ranges between 12 keV to 300 keV and 12 keV through 2,500 keV revealed the residual activation products 56Co, 57Co, 58Co, 54Mn, and 183Re at 264 d post-irradiation. Spectral examinations of the different foils removed between 2003 and 2005 show the same activation products regardless of the irradiation time or foil position in the target assembly. The information presented in this paper can be used along with the integrated charge incident on the foils in estimating the activity of Havar foils for the purpose of disposal.

  14. Coil Occlusion of the Patent Ductus Arteriosus: Lessons Learned

    International Nuclear Information System (INIS)

    Sanatani, Shubhayan; Potts, James E.; Ryan, Angela; Sandor, George G.S.; Human, Derek G.; Culham, J.A. Gordon

    2000-01-01

    Purpose: To review the clinical outcomes of catheter-directed coil occlusion (coil occlusion) of persistently patent ductus arteriosus (PDA) at a pediatric tertiary care hospital.Methods: A retrospective review of all patients referred to the Cardiac Catheterization Laboratory for coil occlusion at our institution was performed. Twenty-one consecutive patients (12 female) underwent coil occlusion and follow-up between May 1995 and December 1997. We undertook PDA occlusion if: (a) the PDA narrowed to less than 4 mm on echocardiogram and (b) the minimum body weight was approximately 10 kg. Standard right and retrograde left heart catheterization was performed, followed by coil occlusion. Color-flow mapping (CFM) was used intra-procedurally to confirm occlusion of the PDA with a follow-up study several weeks later.Results: The median age and weight of the patients were 33 months and 13.2 kg, respectively. Fourteen patients received one coil, with six requiring a second coil and one requiring multiple coils. Initial follow-up was at a median of 2.4 months. At latest follow-up, 2 patients still have persistent flow at the ductal level. The coils were deployed without complication or embolization.Conclusions: A review of our first 21 cases demonstrated three important lessons: (1) the maximum diameter of the PDA suitable for coil occlusion is approximately 3 mm; (2) CFM must show complete obliteration of flow in the catheterization lab in order to ensure occlusion of the PDA at follow-up; and (3) the Jackson detachable system allows for precise placement of the coil, often within another coil

  15. Detection and tracking of moving objects under occlusion and shadow

    Science.gov (United States)

    Ming, Ying; Jiang, Jingjue

    2005-10-01

    This paper presents a system to detect and track multiple moving objects in the presence of mutual occlusion and shadow. A novel change detection algorithm based on Cauchy distribution is proposed. The ratio of pixel's intensities between two images is used as the feature to model and subtract background. The distribution of the ratio of background pixel's intensities between a current image and a reference image can obeys Cauchy distribution, assumed that some observed temporal intensity variation of each pixel in a background image is caused by white noise. By hypothesis testing whose decision thresholds are related to the false alarm rate, robust change detection can be carried out. We exploit spectral and geometrical properties of shadows to recognize and eliminate them in video sequences. Intensity, hue and saturation in the YCbCr color space is employed to this end. In order to solve ambiguity due to occlusion and recover from intermittent tracking failure, we propose a method to implement tracking of multiple moving objects. The method is based on multi-cue and dynamic templates matching in consecutive frames and motion estimation by Kalman filter. In our system, a fast accurate clustering algorithm based on k-nearest neighbor search is employed and the feature space is constructed by extracting the position, color, shape and velocity information of moving objects. In this paper, occlusions are addressed in two classes, i.e. static occlusion and dynamic occlusion. Depend on the prior knowledge of the background scene and the feedback from objects detection and tracking, the distribution of static occlusion region in the scene can be acquired and updated. The bounding box around a static occlusion region is used as an alarm sign to start the process of static occlusion. Dynamic occlusion event can be detected and processed in terms of the proposed tracking scheme and multi-cue and dynamic templates matching approach. Experiment results demonstrate that the

  16. Undulatory locomotion of flexible foils as biomimetic models for understanding fish propulsion.

    Science.gov (United States)

    Shelton, Ryan M; Thornycroft, Patrick J M; Lauder, George V

    2014-06-15

    An undulatory pattern of body bending in which waves pass along the body from head to tail is a major mechanism of creating thrust in many fish species during steady locomotion. Analyses of live fish swimming have provided the foundation of our current understanding of undulatory locomotion, but our inability to experimentally manipulate key variables such as body length, flexural stiffness and tailbeat frequency in freely swimming fish has limited our ability to investigate a number of important features of undulatory propulsion. In this paper we use a mechanical flapping apparatus to create an undulatory wave in swimming flexible foils driven with a heave motion at their leading edge, and compare this motion with body bending patterns of bluegill sunfish (Lepomis macrochirus) and clown knifefish (Notopterus chitala). We found similar swimming speeds, Reynolds and Strouhal numbers, and patterns of curvature and shape between these fish and foils, suggesting that flexible foils provide a useful model for understanding fish undulatory locomotion. We swam foils with different lengths, stiffnesses and heave frequencies while measuring forces, torques and hydrodynamics. From measured forces and torques we calculated thrust and power coefficients, work and cost of transport for each foil. We found that increasing frequency and stiffness produced faster swimming speeds and more thrust. Increasing length had minimal impact on swimming speed, but had a large impact on Strouhal number, thrust coefficient and cost of transport. Foils that were both stiff and long had the lowest cost of transport (in mJ m(-1) g(-1)) at low cycle frequencies, and the ability to reach the highest speed at high cycle frequencies. © 2014. Published by The Company of Biologists Ltd.

  17. Flapping foil power generator performance enhanced with a spring-connected tail

    Science.gov (United States)

    Liu, Zhengliang; Tian, Fang-Bao; Young, John; Lai, Joseph C. S.

    2017-12-01

    The flexibility effects on the performance of a flapping foil power generator are numerically studied by using the immersed boundary-lattice Boltzmann method at a Reynolds number of 1100. The flapping foil system consists of a rigid NACA0015 foil undergoing harmonic pitch and plunge motions and a passively actuated flat plate pinned to the trailing edge of the rigid foil. The flexibility is modeled by a torsional spring model at the conjuncture of the rigid foil and the tail. Here, a parametric study on mass density and natural frequency is conducted under the optimum kinematic condition of the rigid system identified from the literature and numerical simulations made for reduced frequency f* = 0.04-0.24 and pitch amplitude θ0 = 40°-90°. Four typical cases are discussed in detail by considering time histories of hydrodynamic loads and tail deformations under the optimal and non-optimal kinematic conditions. Results show that under the rigid-system optimal kinematic condition, a tail with appropriate mass density (μ = 0.60) and resonant frequency ( fr*=1.18 ) can improve the maximum efficiency by 7.24% accompanied by an increase of 6.63% in power compared to those of a rigid foil with a rigid tail. This is because the deflection of the tail reduces the low pressure region on the pressure surface (i.e., the lower surface during the upstroke or the upper surface during the downstroke) caused by the leading edge vortex after the stroke reversal, resulting in a higher efficiency. At high flapping frequencies, a spring-connected tail ( fr*=0.13 ) eliminates the large spike in the moment observed in high stiffness cases, reducing the power required for the pitch motion, resulting in 117% improvement in efficiency over that with a rigid tail at a reduced frequency of 0.24.

  18. Extraction of Solar Wind Nitrogen and Noble Gases From the Genesis Gold Foil Collector

    Science.gov (United States)

    Schlutter, D. J.; Pepin, R. O.

    2005-12-01

    The Genesis gold foil is a bulk solar wind collector, integrating fluences from all three of the wind regimes. Pyrolytic extraction of small foil samples at Minnesota yielded He fluences, corrected for backscatter, in good agreement with measurements by on-board spacecraft instruments, and He/Ne elemental ratios close to those implanted in collector foils deployed on the lunar surface during the Apollo missions. Isotopic distributions of He, Ne and Ar are under study. Pyrolysis to temperatures above the gold melting point generates nitrogen blanks large enough to obscure the solar-wind nitrogen component. An alternative technique for nitrogen and noble gas extraction, by room-temperature amalgamation of the gold foil surface, will be discussed. Ne and Ar releases in preliminary tests of this technique on small foil samples were close to 100% of the amounts expected from the high-temperature pyrolysis yields, indicating that amalgamation quantitatively liberates gases from several hundred angstroms deep in the gold, beyond the implantation depth of most of the solar wind. Present work is focused on two problems currently interfering with accurate nitrogen measurements at the required picogram to sub-picogram levels: a higher than expected blank likely due to tiny air bubbles rolled into the gold sheet during fabrication, and the presence of a refractory hydrocarbon film on Genesis collector surfaces (the "brown stain") that, if left in place on the foil, shields the underlying gold from mercury attack. We have found, however, that the film is efficiently removed within tens of seconds by oxygen plasma ashing. Potential nitrogen contaminants introduced during the crash of the sample return canister are inert in amalgamation, and so are not hazards to the measurements.

  19. [Peripheral arterial occlusive disease. Symptoms, basic diagnosis and staged therapy].

    Science.gov (United States)

    Welter, H F; Kettmann, R; Grothe, A

    2002-06-13

    Intermittent claudication or rest pain are typical symptoms of peripheral arterial occlusive disease (PAOD) affecting the lower limbs. The pain is localized one level below that of the occlusion. Initial investigations should determine skin temperature and color, pulse status, stenotic sounds and Doppler occlusive pressures. If intermittent claudication is present, angiography of the pelvis and legs then follows. Treatment is stage-dependent: while in stages I and IIa conservative treatment such as cessation of smoking, administration of acetylsalicylic acid and walking training suffices, stages IIb and higher require invasive measures extending from PTA to amputation of gangrenous parts of the limb.

  20. Observation of Rayleigh-Taylor-like structures in a laser-accelerated foil

    International Nuclear Information System (INIS)

    Whitlock, R.R.; Emery, M.H.; Stamper, J.A.; McLean, E.A.; Obenschain, S.P.; Peckerar, M.C.

    1984-01-01

    Laser-accelerated targets have been predicted to be subject to the Rayleigh-Taylor hydrodynamic instability. The development of the instability was studied by introducing mass thickness variations in foil targets and observing the development of the target nonuniformities by side-on flash x radiography. Observations were made of target structures and mass redistribution effects which resemble Rayleigh-Taylor bubbles and spikes, including not only advanced broadening of the spike tips on the laser-irradiated side of the foil but also projections of mass on the unirradiated side. The observations compare well with numerical simulations

  1. Numerical simulation of non-standard tensile tests of thin metal foils

    Science.gov (United States)

    Bolzon, Gabriella; Shahmardani, Mahdieh

    2018-01-01

    The evolution of the fracture processes occurring in thin metal foils can be evidenced by tensile tests performed on samples of non-standard dimensions. The load versus displacement record of these experiments does not return directly the local stress-strain relationship and the fracture characteristics of the investigated material. In fact, the overall response of thin foils is sensitive to local imperfections, size and geometric effects. Simulation models of the performed tests can support the interpretation of the experimental results, provided that the most significant physical phenomena are captured. The present contribution focuses on the role of modelling details on the numerical output that can be obtained in this context.

  2. Doping of polycrystalline CdTe for high-efficiency solar cells on flexible metal foil

    OpenAIRE

    Kranz Lukas; Gretener Christina; Perrenoud Julian; Schmitt Rafael; Pianezzi Fabian; La Mattina Fabio; Blösch Patrick; Cheah Erik; Chirila Adrian; Fella Carolin M.; Hagendorfer Harald; Jäger Timo; Nishiwaki Shiro; Uhl Alexander R.; Buecheler S.

    2013-01-01

    Roll to roll manufacturing of CdTe solar cells on flexible metal foil substrates is one of the most attractive options for low cost photovoltaic module production. However various efforts to grow CdTe solar cells on metal foil have resulted in low efficiencies. This is caused by the fact that the conventional device structure must be inverted which imposes severe restrictions on device processing and consequently limits the electronic quality of the CdTe layer. Here we introduce an innovative...

  3. Stopping power and scattering angle calculations of charged particle beams through thin foils

    International Nuclear Information System (INIS)

    Nassiri, A.

    1991-03-01

    It is important to understand the effects of introducing foils into the path of charged particle beams. In the APS linac system, the intention is to insert thin foils before and after the positron generating target to protect the accelerating structures immediately before and after the target. Electron beams that pass through a dense material lose energy in collisions with the atomic electrons. The scattering path of electrons is much less straight than that of heavier particles (mu, pi meson, K meson, proton, etc.). After a short distance electrons tend to diffuse into the material, rather than proceeding in a rectilinear path

  4. A finite element framework for distortion gradient plasticity with applications to bending of thin foils

    DEFF Research Database (Denmark)

    Martínez Pañeda, Emilio; Niordson, Christian Frithiof; Bardella, Lorenzo

    2016-01-01

    by Gurtin (2004) through the prescription of a free energy dependent on Nye’s dislocation density tensor. The proposed numerical scheme is developed by following and extending the mathematical principles established by Fleck and Willis (2009). The modeling of thin metallic foils under bending reveals...... a significant influence of the plastic shear strain and spin due to a mechanism associated with the higher-order boundary conditions allowing dislocations to exit the body. This mechanism leads to an unexpected mechanical response in terms of bending moment versus curvature, dependent on the foil length...

  5. Visualization and Measurement of the Deflagration of Metal-Foil Bounded JA2

    Science.gov (United States)

    2015-06-01

    ARL‐TR‐7322 ● JUNE 2015          US Army Research Laboratory      Visualization and Measurement of the  Deflagration of Metal‐ Foil  Bounded...Visualization and Measurement of the  Deflagration of Metal‐ Foil  Bounded JA2    John J Ritter and Anthony Canami  Weapons and Materials Research...

  6. Simulations of micro-bending of thin foils using a scale dependent crystal plasticity model

    DEFF Research Database (Denmark)

    Kuroda, Mitsutoshi; Tvergaard, Viggo; Ohashi, T.

    2007-01-01

    In this paper, we perform crystal plasticity analyses of micro-bending of thin f.c.c. metal foils having thicknesses ranging from 10 to 50 mu m. The scale dependent crystal plasticity model used here is a viscoplastic finite strain version of the model proposed by Ohashi (2005 Int. J. Plast. 21...... a Bailey-Hirsch type relation. The computational results are compared with the experimental results for Ni foils, reported in Stolken and Evans (1998 Acta Mater. 46 5109-15). The validity of the current model and the direction of future development of the 'physically-based' scale dependent crystal...

  7. Femtosecond laser ablation of silver foil with single and double pulses

    CSIR Research Space (South Africa)

    Roberts, DE

    2009-01-01

    Full Text Available /apsusc r ablation of silver foil with single and double pulses, Appl. Surf. D.E. Roberts et al. / Applied Surface Science xxx (2009) xxx–xxx2 G Model APSUSC-19322; No of Pages 9 pulses used for ablation. While there has been much overlap in the aims... value r ablation of silver foil with single and double pulses, Appl. Surf. ; lon D.E. Roberts et al. / Applied Surface Science xxx (2009) xxx–xxx 3 G Model APSUSC-19322; No of Pages 9 Fig. 1. Surface temperature versus time calculated for double...

  8. Chemical etching of copper foils for single-layer graphene growth by chemical vapor deposition

    Science.gov (United States)

    Yoshihara, Naoki; Noda, Masaru

    2017-10-01

    Chemical etching on copper surface is essential as a pre-treatment for single-layer graphene growth by chemical vapor deposition (CVD). Here, we investigated the effect of chemical etching treatment on copper foils for single-layer graphene CVD growth. The chemical etching conditions, such as the type of chemical etchants and the treatment time, were found to strongly influence the graphene domain size. Moreover, a drastic change in the layer structure of graphene sheets, which was attributed to the surface morphology of the etched copper foil, was confirmed by graphene transmittance and Raman mapping measurements.

  9. Potentiality of the composite fulleren based carbon films as the stripper foils for tandem accelerators

    CERN Document Server

    Vasin, A V; Rusavsky, A V; Totsky, Y I; Vishnevski, I N

    2001-01-01

    The problem of the radiation resistance of the carbon stripper foils is considered. The short review of the experimental data available in literature and original experimental results of the are presented. In the paper discussed is the possibility of composite fulleren based carbon films to be used for preparation of the stripper foils. Some technological methods for preparation of composite fulleren based carbon films are proposed. Raman scattering and atom force microscopy were used for investigation of the fulleren and composite films deposited by evaporation of the C sub 6 sub 0 fulleren powder.

  10. Quality assurance of GEM foils in the framework of the TPC upgrade in the ALICE experiment

    CERN Document Server

    Ozcelik, Melih Arslan

    2016-01-01

    In the framework of the TPC upgrade of the ALICE Experiment, new readout chambers will be installed during the LHC long shutdown 2, which is scheduled to start in July 2018. The current MWPCs (Multi Wire Proportional Chambers) will be replaced by readout chambers consisting of GEM (Gas Electron Multipliers) foils in order to meet the increasing readout rate requirements. QA (Quality Assurance) tests on the GEMs are performed to classify the foils. In this report we present the work done during the CERN Summer Student Programme 2016.

  11. Wake structure and thrust generation of a flapping foil in two-dimensional flow

    DEFF Research Database (Denmark)

    Andersen, Anders Peter; Bohr, Tomas; Schnipper, Teis

    2017-01-01

    We present a combined numerical (particle vortex method) and experimental (soap film tunnel) study of a symmetric foil undergoing prescribed oscillations in a two-dimensional free stream. We explore pure pitching and pure heaving, and contrast these two generic types of kinematics. We compare...... measurements and simulations when the foil is forced with pitching oscillations, and we find a close correspondence between flow visualisations using thickness variations in the soap film and the numerically determined vortex structures. Numerically, we determine wake maps spanned by oscillation frequency...

  12. Hydrodynamic simulations of light ion beam-matter interactions: ablative acceleration of thin foils

    International Nuclear Information System (INIS)

    Devore, C.R.; Gardner, J.H.; Boris, J.P.; Mosher, D.

    1984-01-01

    A one-dimensional model is used to study the hydrodynamic response of thin foils to bombardment by an intense proton beam. The beam targets are single- and multilayer planar foils of gold and polystyrene. The main conclusion is that the efficiency of conversion of incident beam energy to directed kinetic energy of the target is maximized by using a multilayer design. For beam parameters associated with the Gamble II device at the Naval Research Laboratory, the simulations yield payload velocities of over 5 cm/μs and energy conversion efficiencies of over 30%. The implications of these results for inertial confinement fusion research are discussed. (author)

  13. First storage of ultracold neutrons using foils coated with diamond-like carbon

    International Nuclear Information System (INIS)

    Atchison, F.; Brys, T.; Daum, M.; Fierlinger, P.; Geltenbort, P.; Henneck, R.; Heule, S.; Kasprzak, M.; Kirch, K.; Pichlmaier, A.; Plonka, C.; Straumann, U.; Wermelinger, C.

    2005-01-01

    For the first time, ultracold neutrons have been stored in a volume formed of foils coated with diamond-like carbon. The coefficients for loss, η, and depolarization, β, per wall collision were determined simultaneously. The results for different samples, η∼10 -4 and β∼10 -5 -10 -6 , are among the best values measured for high Fermi potential materials without elaborate surface pre-treatment. Thin foil storage material will be widely applicable, e.g., in neutron β-decay studies

  14. First storage of ultracold neutrons using foils coated with diamond-like carbon

    Energy Technology Data Exchange (ETDEWEB)

    Atchison, F. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Brys, T. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Daum, M. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Fierlinger, P. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Physik-Institut, Universitaet Zuerich (Switzerland); Geltenbort, P. [ILL, Institut Laue-Langevin, Grenoble (France); Henneck, R. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Heule, S. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Physik-Institut, Universitaet Zuerich (Switzerland); Kasprzak, M. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); SMI, Stefan-Meyer-Institut, Vienna (Austria); Kirch, K. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Pichlmaier, A. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)]. E-mail: axel.pichlmaier@psi.ch; Plonka, C. [ILL, Institut Laue-Langevin, Grenoble (France); Straumann, U. [Physik-Institut, Universitaet Zuerich (Switzerland); Wermelinger, C. [PSI, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); ETHZ, Eidgenoessische Technische Hochschule Zuerich (Switzerland)

    2005-10-06

    For the first time, ultracold neutrons have been stored in a volume formed of foils coated with diamond-like carbon. The coefficients for loss, {eta}, and depolarization, {beta}, per wall collision were determined simultaneously. The results for different samples, {eta}{approx}10{sup -4} and {beta}{approx}10{sup -5}-10{sup -6}, are among the best values measured for high Fermi potential materials without elaborate surface pre-treatment. Thin foil storage material will be widely applicable, e.g., in neutron {beta}-decay studies.

  15. Large-area thin self-supporting carbon foils with MgO coatings

    CERN Document Server

    Stolarz, A

    2002-01-01

    Large area self-supporting carbon foils in the thickness of range of 8-22 mu g/cm sup 2 , coated with approximately 4 mu g/cm sup 2 MgO have been prepared by e-gun evaporation. They were mounted on frames with apertures of 130 cm sup 2. Problems related to the parting agent preparation, floating procedure, and mounting onto frames are discussed. Special precautions necessary to avoid damage during foil drying, storage and transportation are suggested.

  16. Effect of thickness of foil strippers in transmission of beams through 15 UD pelletron accelerator at IUAC

    International Nuclear Information System (INIS)

    Ojha, S.; Pankaj Kumar; Gargari, S.; Joshi, R.; Abhilash; Kabiraj, D.; Chopra, S.

    2009-01-01

    15 UD Pelletron accelerator at IUAC, New Delhi is equipped with a foil stripper and a gas stripper at high voltage terminal. Besides these, we have foil stripper assemblies at High Energy Dead Section (HEDS) of Pelletron and after analyser magnet. Incoming negative ion looses electrons when they pass through the strippers at terminal and becomes positively charged. The next foil stripper at HEDS increases the positive charge state of ion by removing more electrons which helps in delivering beams at higher energy. Typical thickness of carbon foils loaded in the foil stripper assembly in the terminal is around 4 microgram per square centimetre (4 μg/cm 2 ). Thicker foils were installed in the terminal assembly to study the effect of thickness of foil on charge state distribution and transmission of ion beams. Charge state distribution of ions produced out of molecular beam was also studied. In this paper we present and discuss the results and observations with thicker foils on ion as well as molecular beams. (author)

  17. Transcranial Doppler US as an alternative to angiography and balloon occlusion in estimating risk of carotid occlusion

    International Nuclear Information System (INIS)

    Feaster, S.H.; Powers, A.; Laws, E.R.

    1990-01-01

    This paper demonstrates the reliability of transcranial Doppler (TCD) US in the evaluation of the adequacy of collateral vessel cerebral blood flow in patients being considered for carotid ligation or occlusion. TCD was utilized in 12 patients in an attempt to study collateral vessel blood flow during endovascular balloon occlusion of a carotid artery. This was correlated with TCD measurements performed during manual carotid compression and with cerebral angiography. Changes of blood flow velocity were measured in the ipsilateral MCA and ACA. Excellent correlation was noted between the TCD measurements during manual carotid compression and actual endovascular balloon occlusion. There was also qualitative agreement with the cross-compression angiogram

  18. Preserving esthetics, occlusion and occlusal vertical dimension in a patient with fixed prostheses seeking dental implant treatment.

    Science.gov (United States)

    Al Baker, Abdulaziz; Habib, Syed Rashid; Al Amri, Mohammad D

    2016-10-01

    The preservation of esthetics and occlusal vertical dimension is critical in patients with existing full-arch tooth-retained fixed prostheses. This clinical report describes the provision of a maxillary immediate complete denture in a patient with a maxillary full-arch fixed dental prosthesis over nonviable teeth. The existing fixed dental prosthesis was used in the fabrication of the maxillary immediate complete denture to preserve esthetics. The technique involved recording and preservation of the occlusal vertical dimension and occlusion of the existing prosthesis. The technique is simple, quick, cost-effective and less challenging clinically and technically.

  19. Surgical treatment of chronic aortoiliac occlusion

    Directory of Open Access Journals (Sweden)

    Márcio Luís Lucas

    2015-03-01

    Full Text Available BACKGROUND: Chronic aortoiliac occlusion (CAIO is a significant cause of lower limb ischemia and is often found in young patients who smoke. OBJECTIVE: To review recent results achieved treating CAIO patients with open surgery. METHODS: From November 2011 to April 2014, 21 patients with CAIO were treated at the Santa Casa de Misericórdia, Porto Alegre, Brazil. Demographic data, comorbidities, clinical presentation and surgical results were analyzed. RESULTS: Eleven women and ten men were treated with direct aortic bypass (DAB; n=18 or with extra-anatomic bypass (EAD; n=3. Mean age was 53.7 ± 7.3 years (range: 43-79 years and all patients smoked. Thirteen patients (62% had critical ischemia. Six of the patients treated with DAB (33.4% also required additional revascularization (3 renal and 3 femoropopliteal procedures. Perioperative mortality was zero. Four patients (22.2% suffered transitory renal dysfunction, but only one patient (5.6% required hemodialysis. Median follow-up time was 17 months (range: 2-29 months and there was just one late death, from ischemic heart disease, 7 months after the surgery on the abdominal aorta. CONCLUSIONS: Aortic reconstruction is a safe method for treating patients with CAIO, with low perioperative morbidity and mortality rates.

  20. Fetal MRI in experimental tracheal occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, Ulrike [Department of Diagnostic and Interventional Radiology, Universitaetsklinikum Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)]. E-mail: wedegaer@uke.uni-hamburg.de; Schroeder, Hobe J. [Experimental Gynecology, Department of Obstetrics and Prenatal Medicine, Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany); Adam, Gerhard [Department of Diagnostic and Interventional Radiology, Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany)

    2006-02-15

    Congenital diaphragmatic hernia (CDH) is associated with a high mortality, which is mainly due to pulmonary hypoplasia and secondary pulmonary hypertension. In severely affected fetuses, tracheal occlusion (TO) is performed prenatally to reverse pulmonary hypoplasia, because TO leads to accelerated lung growth. Prenatal imaging is important to identify fetuses with pulmonary hypoplasia, to diagnose high-risk fetuses who would benefit from TO, and to monitor the effect of TO after surgery. In fetal imaging, ultrasound (US) is the method of choice, because it is widely available, less expensive, and less time-consuming to perform than magnetic resonance imaging (MRI). However, there are some limitations for US in the evaluation of CDH fetuses. In those cases, MRI is helpful because of a better tissue contrast between liver and lung, which enables evaluation of liver herniation for the diagnosis of a high-risk fetus. MRI provides the ability to determine absolute lung volumes to detect lung hypoplasia. In fetal sheep with normal and hyperplastic lungs after TO, lung growth was assessed on the basis of cross-sectional US measurements, after initial lung volume determination by MRI. To monitor fetal lung growth after prenatal TO, both MRI and US seem to be useful methods.

  1. Serial dependence promotes object stability during occlusion

    Science.gov (United States)

    Liberman, Alina; Zhang, Kathy; Whitney, David

    2016-01-01

    Object identities somehow appear stable and continuous over time despite eye movements, disruptions in visibility, and constantly changing visual input. Recent results have demonstrated that the perception of orientation, numerosity, and facial identity is systematically biased (i.e., pulled) toward visual input from the recent past. The spatial region over which current orientations or face identities are pulled by previous orientations or identities, respectively, is known as the continuity field, which is temporally tuned over the past several seconds (Fischer & Whitney, 2014). This perceptual pull could contribute to the visual stability of objects over short time periods, but does it also address how perceptual stability occurs during visual discontinuities? Here, we tested whether the continuity field helps maintain perceived object identity during occlusion. Specifically, we found that the perception of an oriented Gabor that emerged from behind an occluder was significantly pulled toward the random (and unrelated) orientation of the Gabor that was seen entering the occluder. Importantly, this serial dependence was stronger for predictable, continuously moving trajectories, compared to unpredictable ones or static displacements. This result suggests that our visual system takes advantage of expectations about a stable world, helping to maintain perceived object continuity despite interrupted visibility. PMID:28006066

  2. Severity of Occlusal Disharmonies in Down Syndrome

    Directory of Open Access Journals (Sweden)

    Danielle Bauer

    2012-01-01

    Full Text Available Objective. To quantify the severity of malocclusion and dental esthetic problems in untreated Down syndrome (DS and untreated non-Down syndrome children age 8–14 years old using the PAR and ICON Indices. Materials and Methods. This retrospective study evaluated pretreatment study models, intraoral photographs, and panoramic radiographs of 30 Down syndrome and two groups of 30 non-Down syndrome patients (private practice and university clinic age 8–14 years. The models were scored via PAR and ICON Indices, and descriptive characteristics such as Angle classification, missing or impacted teeth, crossbites, open bites, and other dental anomalies were recorded. Results. The DS group had significantly greater PAR and ICON scores, as well as 10 times more missing teeth than the non-DS group. The DS group possessed predominantly Class III malocclusions, with the presence of both anterior and posterior crossbites in a majority of the patients. The non-DS group had mostly Class I or II malocclusion with markedly fewer missing teeth and crossbites. The DS group also had more severe malocclusions based upon occlusal traits such as open bite and type of malocclusion. Conclusion. The DS group had very severe malocclusions, while the control group from the university clinic had more severe malocclusions than a control group from a private practice.

  3. Mesiodistal angulation of the lateral teeth to the functional occlusal plane in normal occlusions

    Directory of Open Access Journals (Sweden)

    Hiroshi Ueda

    2016-01-01

    Full Text Available Introduction: Crowding is a malocclusion with irregularly positioned teeth caused by arch length discrepancy (ALD. Its incidence is high compared with the various malocclusions. In a previous study the crowns of the maxillary lateral teeth had erupted mesially in relation to the functional occlusal plane (FOP in patients with Angle Class I malocclusion and highly erupted canines, which had been uprighted by non-extraction orthodontic treatment, yet these results were based on only two cases evaluated by using plaster models. Therefore, the aim of this study was to assess the mesiodistal angulations of both maxillary and mandibular teeth relative to the FOP in normal occlusion by means of cephalograms and identifying the teeth axial factors contributing to the normal dentitions with the least ALD. Materials and Methods: Thirty Japanese young adult patients (6 males, 24 females with normal occlusion were selected to participate in this study; cephalograms were procured from each and the FOP was used as a reference plane for measuring the changes in the axial angulation along with other indicators of vertical growth. Results: Progressive mesial tipping of the maxillary lateral teeth was observed. First premolars tended to express this more than the second premolars but the tipping values were roughly 90° relative to the FOP on the first molars. Conclusion: The maxillary lateral teeth are more mesially angulated compared to the mandibular ones relative to the FOP. Furthermore, progressive mesial tipping of the maxillary lateral teeth was detected, of which axial angulations were significantly correlated to each other, in spite the mandibular premolars and molars being angulated in a similar fashion.

  4. Research of plating aluminum and aluminum foil on internal surface of carbon fiber composite material centrifuge rotor drum

    International Nuclear Information System (INIS)

    Lu Xiuqi; Dong Jinping; Dai Xingjian

    2014-01-01

    In order to improve the corrosion resistance, thermal conductivity and sealability of the internal surface of carbon fiber/epoxy composite material centrifuge rotor drum, magnetron sputtering aluminum and pasting an aluminum foil on the inner wall of the drum are adopted to realize the aim. By means of XRD, SEM/EDS and OM, the surface topography of aluminum coated (thickness of 5 μm and 12 μm) and aluminum foil (12 μm) are observed and analyzed; the cohesion of between aluminum coated (or aluminum foil) and substrate material (CFRP) is measured by scratching experiment, direct drawing experiment, and shear test. Besides, the ultra-high-speed rotation experiment of CFRP ring is carried out to analyze stress and strain of coated aluminum (or aluminum foil) which is adhered on the ring. The results showed aluminum foil pasted on inner surface do better performance than magnetron sputtering aluminum on CFRP centrifuge rotor drum. (authors)

  5. Central Retinal Vein Occlusion AssociatedWith Sildenafil (Viagra

    Directory of Open Access Journals (Sweden)

    H C Obiudu

    2010-01-01

    Conclusion - Central retinal vein occlusion is a possible adverse effect of sildenafil use. Physicians should be vigilant while prescribing thismedication and avoid its use in patients with elevated intraocular pressure

  6. Celiac artery stenosis/occlusion treated by interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)], E-mail: osamu-3643ik@do9.enjoy.ne.jp; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)

    2009-08-15

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  7. Avoiding occlusal derangement in facial fractures: An evidence based approach

    Directory of Open Access Journals (Sweden)

    Derick Mendonca

    2013-01-01

    Full Text Available Facial fractures with occlusal derangement describe any fracture which directly or indirectly affects the occlusal relationship. Such fractures include dento-alveolar fractures in the maxilla and mandible, midface fractures - Le fort I, II, III and mandible fractures of the symphysis, parasymphysis, body, angle, and condyle. In some of these fractures, the fracture line runs through the dento-alveolar component whereas in others the fracture line is remote from the occlusal plane nevertheless altering the occlusion. The complications that could ensue from the management of maxillofacial fractures are predominantly iatrogenic, and therefore can be avoided if adequate care is exercised by the operating surgeon. This paper does not emphasize on complications arising from any particular technique in the management of maxillofacial fractures but rather discusses complications in general, irrespective of the technique used.

  8. [Occlusal anomalies in the deciduous and mixed bites].

    Science.gov (United States)

    Legovic, M; Mady, L

    1998-01-01

    In 311 examines (177 boys and 134 girls) with primary dentition and 535 examinees (285 boys and 250 girls) with mixed dentition in Istria--Croatia, the frequency of orthodontic and occlusive anomalies in regard of space plane and premature extraction of c, m1 and m2 are investigated. The orthodontic anomalies are defected in 46.95%, premature loss in 11.25% and occlusive anomalies in 40.85% of examinees with primary dentition, while in mixed dentition the 58.69% of examinees have orthodontic anomaly, the 17.20% premature loss and the 48.97% of examinees have occlusal anomaly. In both phases of dentition the most frequent are occlusive anomalies in the following planes: sagittal, vertical and sagittal-vertical.

  9. Occlusal accommodation and mouthguards for prevention of orofacial trauma.

    LENUS (Irish Health Repository)

    Geary, Julian Lindsay

    2009-01-01

    The aim of this study was to investigate the effect of two types of occlusal accommodation on the arch separation in centric and eccentric arch positions and to assess the opposing tooth contacts in professionally made, thermoformed sports mouthguards.

  10. Image Based Solution to Occlusion Problem for Multiple Robots Navigation

    Directory of Open Access Journals (Sweden)

    Taj Mohammad Khan

    2012-04-01

    Full Text Available In machine vision, occlusions problem is always a challenging issue in image based mapping and navigation tasks. This paper presents a multiple view vision based algorithm for the development of occlusion-free map of the indoor environment. The map is assumed to be utilized by the mobile robots within the workspace. It has wide range of applications, including mobile robot path planning and navigation, access control in restricted areas, and surveillance systems. We used wall mounted fixed camera system. After intensity adjustment and background subtraction of the synchronously captured images, the image registration was performed. We applied our algorithm on the registered images to resolve the occlusion problem. This technique works well even in the existence of total occlusion for a longer period.

  11. Acute complications of percutaneous transluminal coronary angioplasty for total occlusion

    NARCIS (Netherlands)

    S. Plante (Sylvain); G-J. Laarman (GertJan); P.J. de Feyter (Pim); M. Samson; B.J.W.M. Rensing (Benno); V.A.W.M. Umans (Victor); H. Suryapranata (Harry); M.J.B.M. van den Brand (Marcel); P.W.J.C. Serruys (Patrick)

    1991-01-01

    markdownabstractAbstract The incidence of major complications after percutaneous coronary angioplasty (PTCA) of a totally occluded artery was assessed retrospectively. A total of 1649 PTCA procedures were analyzed. After exclusion of procedures for acute myocardial infarction or total occlusion

  12. Shape Recognition in Presence of Occlusion from Fourier Plane Processing

    Science.gov (United States)

    Pohit, Mausumi; Goel, Alpana

    2011-10-01

    A new technique for recognition of objects in presence of occlusion is presented in this paper. The Fourier spectrum of a partially occluded shape differs from that of the whole object shape thereby decreasing the 2D correlation between two images. The present method is based on 1D correlation of Fourier Spectrum slices taken from the 2D Fourier Transform of the reference and the test object. For small occlusion, some of the slices are affected depending on the nature of occlusion. Responses of the rest of the slices are unaffected. This study shows that this method not only identify the object in presence of occlusion but at the same time has good discrimination capability.

  13. Full Body Pose Estimation During Occlusion using Multiple Cameras

    DEFF Research Database (Denmark)

    Fihl, Preben; Cosar, Serhan

    Automatic estimation of the human pose enables many interesting applications and has therefore achieved much attention in recent years. One of the most successful approaches for estimating unconstrained poses has been the pictorial structures framework. However, occlusions between interacting...

  14. Amplatzer vascular plug for rapid vessel occlusion in interventional neuroradiology.

    Science.gov (United States)

    Banfield, Jillian C; Shankar, Jai Jai Shiva

    2016-02-01

    The purpose of this paper is to report different uses of endovascular Amplatzer vascular plug (AVP) treatment for rapid vessel occlusion in the field of interventional neuroradiology. We retrospectively reviewed our interventional neuroradiology database from November 2010 to July 2015 and found nine patients who were treated with endovascular AVP. AVP was used for rapid vessel occlusion of common carotid artery (1 patient), internal carotid artery (5 patients), vertebral artery (2 patients), and internal jugular vein (1 patient). A median of three AVPs were used with almost immediate occlusion and no thromboembolic complications. Use of AVP is feasible, safe, rapid, and potentially cost-effective method for rapid occlusion of larger size vessels in the head and neck region for different indications. © The Author(s) 2015.

  15. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease

    NARCIS (Netherlands)

    Groot Jebbink, Erik; Mathai, Varghese; Boersen, Johannes Thomas; Sun, Chao; Slump, Cornelis H.; Goverde, Peter C.J.M.; Versluis, Michel; Reijnen, Michel M.P.J.

    Background Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry

  16. Hepatic veno-occlusive disease associated with comfrey ingestion.

    Science.gov (United States)

    Yeong, M L; Swinburn, B; Kennedy, M; Nicholson, G

    1990-01-01

    A 23 year old man presented with hepatic veno-occlusive disease and severe portal hypertension and subsequently died from liver failure. Light microscopy and hepatic angiography showed occlusion of sublobular veins and small venous radicles of the liver, associated with widespread haemorrhagic necrosis of hepatocytes. The patient had been on a predominantly vegetarian diet and, prior to his illness, took comfrey leaves which are known to contain hepatotoxic pyrrolizidine alkaloids. Comfrey is widely used as a herbal remedy, but so far has only been implicated in two other documented cases of human hepatic veno-occlusive disease. A possible causal association of comfrey and this patient's veno-occlusive disease is suggested by the temporal relationship of the ingestion of comfrey to his presentation, the histological changes in the liver and the exclusion of other known causes of the disease.

  17. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    Directory of Open Access Journals (Sweden)

    Mihir Kothari

    2014-01-01

    Full Text Available Part time occlusion therapy is not reported to cause occlusion (reverse amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  18. Preprosthetic therapy utilizing a temporary occlusal acrylic splint: a case report.

    Science.gov (United States)

    Badel, Tomislav; Kraljeviç, Sonja; Panduriç, Josip; Marotti, Miljenko

    2004-05-01

    This case report describes the complex occlusal rehabilitation of a patient with signs and symptoms of temporomandibular disorders with utilization of an occlusal acrylic splint as a means of initial treatment for neuromuscular reprogramming and repositioning of the condyle within the mandibular fossa for occlusal stability, thus allowing adaptation to a new occlusal vertical dimension.

  19. The Inflammatory Sequelae of Aortic Balloon Occlusion in Hemorrhagic Shock

    Science.gov (United States)

    2014-04-13

    metabolic profile was significantly different. Clamp occlusion was associated with a significantly higher lactate burden and vasopressor requirement in...balloon occlusion. This was associated with a significant metabolic burden as measured by serum lactate; however, with suitable resuscitation, this...interleukin 10, reduces nuclear factor kB DNA binding, and improves short term survival in lethal endotoxemia . Crit Care Med 2004;32:801. [36] Manning JE

  20. An adaptive occlusion culling algorithm for use in large ves

    DEFF Research Database (Denmark)

    Bormann, Karsten

    2000-01-01

    The Hierarchical Occlusion Map algorithm is combined with Frustum Slicing to give a simpler occlusion-culling algorithm that more adequately caters to large, open VEs. The algorithm adapts to the level of visual congestion and is well suited for use with large, complex models with long mean free ...... line of sight ('the great outdoors'), models for which it is not feasible to construct, or search, a database of occluders to be rendered each frame....