WorldWideScience

Sample records for bangerter occlusion foils

  1. Oscillating foil propulsion

    OpenAIRE

    Hauge, Jacob

    2013-01-01

    Unsteady foil theory is discussed and applied on several cases of an oscillating foil. The oscillating foil is meant as a propulsion system for a platform supply vessel.Four case studies of foil oscillation have been performed. A thrust coefficient of 0.1 was achieved at an efficiency of 0.75. A thrust coefficient of minimum 0.184 is necessary to overcome the calm water resistance of the foil.Issues connected to coupled vessel-foil models are discussed.

  2. Uniformity of aluminium foils

    International Nuclear Information System (INIS)

    Commercially produced rolled and beaten Al foils and evaporated Al foils have been examined for thickness uniformity with an areal resolution of about 5 x 10-6 cm2 by measurements of proton backscattering yield using the Harwell microbeam facility. The evaporated Al foils were found to be uniform to better than 1% but the rolled foils were found to have non-uniformities of as much as 5-10% of their mean thickness. This is sufficient to contribute significantly to systematic errors in measurement of fast heavy ion energy straggling. (Auth.)

  3. Retinal vein occlusion

    Science.gov (United States)

    Central retinal vein occlusion; Branch retinal vein occlusion; CRVO; BRVO ... Retinal vein occlusion is most often caused by hardening of the arteries ( atherosclerosis ) and the formation of a blood clot. Blockage ...

  4. Foil Face Seal Testing

    Science.gov (United States)

    Munson, John

    2009-01-01

    In the seal literature you can find many attempts by various researchers to adapt film riding seals to the gas turbine engine. None have been successful, potential distortion of the sealing faces is the primary reason. There is a film riding device that does accommodate distortion and is in service in aircraft applications, namely the foil bearing. More specifically a foil thrust bearing. These are not intended to be seals, and they do not accommodate large axial movement between shaft & static structure. By combining the 2 a unique type of face seal has been created. It functions like a normal face seal. The foil thrust bearing replaces the normal primary sealing surface. The compliance of the foil bearing allows the foils to track distortion of the mating seal ring. The foil seal has several perceived advantages over existing hydrodynamic designs, enumerated in the chart. Materials and design methodology needed for this application already exist. Also the load capacity requirements for the foil bearing are low since it only needs to support itself and overcome friction forces at the antirotation keys.

  5. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... arterial thrombosis; Renal artery embolism; Acute renal artery occlusion; Embolism - renal artery ... often result in permanent kidney failure. Acute arterial occlusion of the renal artery can occur after injury ...

  6. Hydrogel based occlusion systems

    OpenAIRE

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A.; Mendes, E.; Neves, H.P.; Herijgers, P.; Verbrugghe, Y.; Shacham, Y; Engel, L.; Krylov, V.

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a target occlusion location. The hydrogel is configured to permanently occlude the target occlusion location in the swollen state. The hydrogel may be an electro-activated hydrogel (EAH) which could be ...

  7. Process for anodizing aluminum foil

    International Nuclear Information System (INIS)

    In an integrated process for the anodization of aluminum foil for electrolytic capacitors including the formation of a hydrous oxide layer on the foil prior to anodization and stabilization of the foil in alkaline borax baths during anodization, the foil is electrochemically anodized in an aqueous solution of boric acid and 2 to 50 ppm phosphate having a pH of 4.0 to 6.0. The anodization is interrupted for stabilization by passing the foil through a bath containing the borax solution having a pH of 8.5 to 9.5 and a temperature above 800 C. and then reanodizing the foil. The process is useful in anodizing foil to a voltage of up to 760 V

  8. Occlusion effects, Part II

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    The present report studies the mechanism of the occlusion effect by means of literature studies, experiments and model estimates. A mathematical model of the occlusion effect is developed. The model includes the mechanical properties of the earmould and the airborne sound as well as the body...

  9. Retinal artery occlusion

    Science.gov (United States)

    ... artery occlusion; Branch retinal artery occlusion; CRAO; BRAO Images Retina References Sanborn GE, Magargal LE. Arterial obstructive disease ... A.M. Editorial team. Related MedlinePlus Health Topics ... audit to verify that A.D.A.M. follows rigorous standards of quality and accountability. A.D.A.M. is among ...

  10. Hydrogel based occlusion systems

    NARCIS (Netherlands)

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A.; Mendes, E.; Neves, H.P.; Herijgers, P.; Verbrugghe, Y.; Shacham, Y.; Engel, L.; Krylov, V.

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a tar

  11. Foil electrode sper light source

    International Nuclear Information System (INIS)

    Numerous laser transitions in the visible and near-infrared in four metal vapors (Li, Al, Ca, and Cu) have been observed in the recombination phase of the expanding plasmas produced by a segmented plasma device employing foil electrodes. Also described is a segmented vapor plasma discharge in using Ni foil electrodes

  12. An alternative treatment of occlusal wear: Cast metal occlusal surface

    OpenAIRE

    Sandeep Kumar; Aman Arora; Reena Yadav

    2012-01-01

    Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal sur...

  13. Occlusive Peripheral Arterial Disease

    Science.gov (United States)

    ... erythrocyte sedimentation rate (ESR) and level of C-reactive protein, which is produced only when inflammation is present. ... people with occlusive peripheral arterial disease also have coronary artery disease. Amputation of a limb may be necessary if ...

  14. Follicular occlusion tetrad

    OpenAIRE

    Vani Vasanth; Byalakere Shivanna Chandrashekar

    2014-01-01

    Follicular occlusion tetrad is a symptom complex consisting of four conditions having a similar pathophysiology. It includes Hidradenitis suppurativa, acne conglobata, dissecting cellulitis of the scalp and pilonidal sinus. The exact pathogenesis of this group of disease is unknown but evidence suggests that they share the same pathological process initiated by follicular occlusion in apocrine gland bearing areas. Though each of these conditions is commonly encountered singly, follicular occl...

  15. Mechanical properties of polyethylene foils

    OpenAIRE

    Ľubomír KUBÍK; Stanislav Zeman

    2014-01-01

    The paper deals with the evaluation of the mechanical properties of the polyethylene foils such as the stress, strain, modulus of elasticity and stress and strain in the moment of breaking. The thin foils (50 mm) which contained 91 % of polyethylene Bralen RA 2–63 and 9 % colored concentrate Maxithen were studied. Four sorts of foils were examined: Maxithen HP 1510 – white, Maxithen HP 231111 – yellow, Maxithen HP 533031 – blue and Maxithen HP 533 041 – violet. Longitudinal and transversal te...

  16. Shielding effect of foil covers

    International Nuclear Information System (INIS)

    For neutron spectrum determinations one often irradiates activation detectors in boxes of cadmium, or of another material. Several models for the neutron attenuation in such foil covers are being studied. Preliminary experience is presented. (author)

  17. Hydrogen permeation through metallic foils

    International Nuclear Information System (INIS)

    The process of electrolytic permeation of hydrogen through metallic foils is studied. A double electrolytic cell, in glass, in which the two compartments of reaction are separated by a metallic foil to be studied, was built. As direct result, the hydrogen diffusion coefficient in the metal is obtained. The hydrogen diffusion coefficients in the palladium and, in austenitic stainless steels 304 and 304 L, used in the Angra-1 reactor, were obtained. Samples of stainless steels with and without welding, were used. (Author)

  18. Occlusion effects, Part I

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    When the ear canal is occluded with an earmould, then own voice might sound different and loud sounds are generated when eating and walking. Other effects such as mist and itch do also appear. Hear an investigation is reported which included 48 hearing aid users. The users were asked to fill in a...... questionnaire based on their daily experience with their personal hearing aid. It turned out that 73% of these persons experienced a change in own voice, but both occlusion effects of acoustic, mechanical and biological origin were experienced. The same persons came into Oticon's clinic, where their hearing aid...... fitting and occlusion effect were evaluated. Occlusion effect was measured as the difference in real ear sound pressure level with and without hearing aid while the person was speaking. It was done both with the hearing aid turned off and with the hearing aid turned on. Relations between their experienced...

  19. Retinal vein and artery occlusions

    DEFF Research Database (Denmark)

    Christiansen, Christine Benn; Lip, Gregory Y. H.; Lamberts, Morten;

    2013-01-01

    Retinal vascular occlusions may constitute an independent risk factor for stroke in patients with atrial fibrillation.......Retinal vascular occlusions may constitute an independent risk factor for stroke in patients with atrial fibrillation....

  20. Method for fabricating uranium foils and uranium alloy foils

    Science.gov (United States)

    Hofman, Gerard L.; Meyer, Mitchell K.; Knighton, Gaven C.; Clark, Curtis R.

    2006-09-05

    A method of producing thin foils of uranium or an alloy. The uranium or alloy is cast as a plate or sheet having a thickness less than about 5 mm and thereafter cold rolled in one or more passes at substantially ambient temperatures until the uranium or alloy thereof is in the shape of a foil having a thickness less than about 1.0 mm. The uranium alloy includes one or more of Zr, Nb, Mo, Cr, Fe, Si, Ni, Cu or Al.

  1. Carbon foils for space plasma instrumentation

    Science.gov (United States)

    Allegrini, F.; Ebert, R. W.; Funsten, H. O.

    2016-05-01

    Carbon foils have been successfully used for several decades in space plasma instruments to detect ions and neutral atoms. These instruments take advantage of two properties of the particle-foil interaction: charge conversion of neutral atoms and/or secondary electron emission. This interaction also creates several adverse effects for the projectile exiting the foil, such as angular scattering and energy straggling, which usually act to reduce the sensitivity and overall performance of an instrument. The magnitude of these effects mainly varies with the incident angle, energy, and mass of the incoming projectile and the foil thickness. In this paper, we describe these effects and the properties of the interaction. We also summarize results from recent studies with graphene foils, which can be made thinner than carbon foils due to their superior strength. Graphene foils may soon replace carbon foils in space plasma instruments and open new opportunities for space research in the future.

  2. Left atrial appendage occlusion

    Directory of Open Access Journals (Sweden)

    Ahmad Mirdamadi

    2013-01-01

    Full Text Available Left atrial appendage (LAA occlusion is a treatment strategy to prevent blood clot formation in atrial appendage. Although, LAA occlusion usually was done by catheter-based techniques, especially percutaneous trans-luminal mitral commissurotomy (PTMC, it can be done during closed and open mitral valve commissurotomy (CMVC, OMVC and mitral valve replacement (MVR too. Nowadays, PTMC is performed as an optimal management of severe mitral stenosis (MS and many patients currently are treated by PTMC instead of previous surgical methods. One of the most important contraindications of PTMC is presence of clot in LAA. So, each patient who suffers of severe MS is evaluated by Trans-Esophageal Echocardiogram to rule out thrombus in LAA before PTMC. At open heart surgery, replacement of the mitral valve was performed for 49-year-old woman. Also, left atrial appendage occlusion was done during surgery. Immediately after surgery, echocardiography demonstrates an echo imitated the presence of a thrombus in left atrial appendage area, although there was not any evidence of thrombus in pre-pump TEE. We can conclude from this case report that when we suspect of thrombus of left atrial, we should obtain exact history of previous surgery of mitral valve to avoid misdiagnosis clotted LAA, instead of obliterated LAA. Consequently, it can prevent additional evaluations and treatments such as oral anticoagulation and exclusion or postponing surgeries including PTMC.

  3. Application of an Active Foil Propeller

    OpenAIRE

    Borgen, Christian Thomas

    2010-01-01

    In this master thesis the author has investigated the potential benefits from an active foil propeller. Foils are mounted on the hull and take advantage of the heaving and pitching motion of the vessel travelling and produce thrust, similarly to the tail find of aquatic mammals. Active foil means that the angle of the foil has been controlled to constantly maximise the thrust.The author has investigated the potential fuel savings for three vessels, an offshore supply vessel, a coastal tanker ...

  4. Passive Thermal Management of Foil Bearings

    Science.gov (United States)

    Bruckner, Robert J. (Inventor)

    2015-01-01

    Systems and methods for passive thermal management of foil bearing systems are disclosed herein. The flow of the hydrodynamic film across the surface of bearing compliant foils may be disrupted to provide passive cooling and to improve the performance and reliability of the foil bearing system.

  5. An alternative treatment of occlusal wear: cast metal occlusal surface.

    Science.gov (United States)

    Kumar, Sandeep; Arora, Aman; Yadav, Reena

    2012-01-01

    Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal surfaces, however, these methods are time-consuming, expensive and requires many cumbersome steps. These methods also requires the patient to be without the prosthesis for the time during which the laboratory procedures are performed. This article presents a quick, simple and relatively inexpensive procedure for construction of metal occlusal surfaces on complete dentures. PMID:22945724

  6. An alternative treatment of occlusal wear: Cast metal occlusal surface

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar

    2012-01-01

    Full Text Available Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal surfaces, however, these methods are time-consuming, expensive and requires many cumbersome steps. These methods also requires the patient to be without the prosthesis for the time during which the laboratory procedures are performed. This article presents a quick, simple and relatively inexpensive procedure for construction of metal occlusal surfaces on complete dentures.

  7. Characterization of the GEM foil materials

    CERN Document Server

    Benussi, L; Saviano, G; Muhammad, S; Piccolo, D; Raffone, G; Caponero, M; Passamonti, L; Pierluigi, D; Russo, A; Primavera, F; Cerbelli, S; Lalli, A; Valente, M; Ferrini, M; Teissandier, B; Taborelli, M; Parvis, M; Grassini, S; Tirilló, J; Sarasini, F; Franchi, A V

    2015-01-01

    Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this compound inside the detector's foil can possibly change its mechanical and electrical properties and, in such a way, the detector performance can be affected. To understand this phenomenon, a model is developed with COMSOL Multhiphysics v. 4.3, which described the adsorption and diffusion within the geometry of GEM foil, the concentration profiles and the time required to saturate the foil. The COMSOL model is verified by experimental observations on a GEM foil sample. This note will describe the model and its experimental verification results.

  8. Pulmonary veno-occlusive disease

    Science.gov (United States)

    Pulmonary vaso-occlusive disease ... common among children and young adults. As the disease gets worse, it causes narrowed pulmonary veins, pulmonary artery hypertension , and congestion and swelling ...

  9. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  10. Occlusion, TMDs, and dental education

    Directory of Open Access Journals (Sweden)

    Ash Major M

    2007-01-01

    Full Text Available Abstract The paradigmatic shift to evidence-based dentistry (EBD that relates to occlusal therapy, selective occlusal adjustment (OA and stabilization splints therapy (SS for TMDs has had an unfavourable impact on the teaching of many of the important aspects of occlusion needed in dental practice. The teaching of OA systematically in dental schools has been nearly abandoned because of the belief that OA is an irreversible procedure and gives the impression that it is without merit elsewhere in the management of occlusion. However, a particular dose of knowledge and practice of occlusion that is necessary for all aspects of dental care should be taught systematically in dental schools. The uses and misuses of OA and SS and their limitations should be emphasized because of their importance to bring clinical reality into the dental curriculum. Thus, and irrespective of EBD induced contradictions, OA and SS should still have a significant place in systematically teaching of occlusal therapy. However, there are many more aspects of the management of occlusion that should to be considered. Hopefully, because of their importance, other aspects of the management of occlusion will once again become a significant part of the dental curriculum.

  11. Endograft Limb Occlusion in EVAR

    DEFF Research Database (Denmark)

    Taudorf, M; Jensen, L P; Vogt, K C;

    2014-01-01

    OBJECTIVE: To assess the incidence and outcome of graft limb occlusions after endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA) in a high volume single centre. To quantify iliac artery tortuosity in patients with AAA and correlate this with limb occlusion. DESIGN: Data were......, subsequently, duplex ultrasound imaging was performed. Patients with limb occlusions were identified. For each index patient, two controls were obtained, one immediately preceding and one following the index patient in the consecutive cohort of EVAR patients. METHODS: Demographics and CTA data on limb graft...... occlusions were recorded and compared with a defined control group. Three different indices were used to describe the tortuosity of the iliac vessels based on preoperative CTA: pelvic artery index of tortuosity (PAI), common iliac artery index of tortuosity (CAI), and a visual description of vessel...

  12. Hot foil transducer skin friction sensor

    Science.gov (United States)

    Vranas, T. (Inventor)

    1982-01-01

    The device utilizes foil transducers with only one edge exposed to the fluid flow. The surfaces are polished producing a foil transducer that does not generate turbulence while sufficiently thick to carry the required electrical current for high temperature fluid flow. The assembly utilizes a precut layered metal sandwich with attached electrodes eliminating a need for welding and individual sensor calibration.

  13. Nuclear Propulsion using Thin Foiled Fuel

    Science.gov (United States)

    Takahashi, H.

    1998-11-01

    A new way to produce plasma for nuclear propulsion is proposed. A thin foiled fuel can be used for converting fission energy to propulsion energy efficiently. The fission products coming out of the thin foil directly ionize the hydrogen molecules which are used for propulsion. Thus very small portion of fission energy deposited in the thin foil, and integrity of the thin foiled fuel can be maintained even in high nuclear power. Fuel material with large thermal fission cross-section is preferable to make thin foiled fuel and the heat deposition in the foil can be reduced. To get high power from the foiled fuel assembly, thermal neutrons which are created out from the assembly can be supplied, or the assembly itself can create the high intensity thermal neutrons by self-multiplication. A flexible design of a highly efficient nuclear propulsion system can be made. The thickness of the foil and the maintenance of the thermo-mechanical integrity can be determined from the fission cross-section and the slowing down power for fission products. The talk discusses the issues related to heat removal from the assembly.

  14. Chromic acid anodizing of aluminum foil

    Science.gov (United States)

    Dursch, H.

    1988-01-01

    The success of the Space Station graphite/epoxy truss structure depends on its ability to endure long-term exposure to the LEO environment, primarily the effects of atomic oxygen and the temperture cycling resulting from the 94 minute orbit. This report describes the development and evaluation of chromic acid anodized (CAA) aluminum foil as protective coatings for these composite tubes. Included are: development of solar absorptance and thermal emittance properties required of Al foil and development of CAA parameters to achieve these optical properties; developing techniques to CAA 25 ft lengths of Al foil; developing bonding processes for wrapping the Al foil to graphite/epoxy tubes; and atomic oxygen testing of the CAA Al foil. Two specifications were developed and are included in the report: Chromic Acid Anodizing of Aluminum Foil Process Specification and Bonding of Anodized Aluminum Foil to Graphite/Epoxy Tubes. Results show that CAA Al foil provides and excellent protective and thermal control coating for the Space Station truss structure.

  15. Dress Images on Gold-foil Figures

    DEFF Research Database (Denmark)

    Mannering, Ulla; Andersson Strand, Eva Birgitta

    2009-01-01

    From the Late Iron Age settlement Sorte Muld on Bornholm both gold foil figures with depictions of costumes and textile tools can tell about textile production.......From the Late Iron Age settlement Sorte Muld on Bornholm both gold foil figures with depictions of costumes and textile tools can tell about textile production....

  16. Sequential bilateral retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Padrón-Pérez N

    2014-04-01

    Full Text Available Noel Padrón-Pérez,1 Janny Rosario Aronés,2 Silvia Muñoz,1 Luis Arias-Barquet,1 Jorge Arruga1,31Department of Ophthalmology, Hospital Universitari de Bellvitge, 2Hospital de l'Esperança – Parc de Salut Mar, 3Institut Català de Retina, Barcelona, SpainAbstract: An 86 year old woman experienced a sequential bilateral loss of vision over a period of less than 24 hours. Clinical findings and complementary studies suggested a bilateral atherogenic embolic event. Initially, she presented a superior branch retinal artery occlusion in her right eye followed by a central retinal artery occlusion with cilioretinal artery sparing in her left eye. Some conservative maneuvers performed did not improve visual acuity in the left eye. Supra-aortic Doppler ultrasonography revealed mild right internal carotid artery stenosis and moderate left internal carotid artery stenosis with a small, smooth, and homogeneous plaque. The transthoracic echocardiography showed a severe calcification of the mitral valve with a mild-moderate rim of stenosis. Central retinal artery occlusion and branch retinal artery occlusion are characterized by painless monocular loss of vision. Clinical approach and management attempt to treat the acute event, find the source of the vascular occlusion, and prevent further vascular events from occurring. Giant cell arteritis is a potentially treatable cause of central retinal artery occlusion and should be excluded in every single patient over 50 years old.Keywords: loss of vision, branch retinal artery occlusion, central retinal artery occlusion, Hollenhorst plaque

  17. Circuit design on plastic foils

    CERN Document Server

    Raiteri, Daniele; Roermund, Arthur H M

    2015-01-01

    This book illustrates a variety of circuit designs on plastic foils and provides all the information needed to undertake successful designs in large-area electronics.  The authors demonstrate architectural, circuit, layout, and device solutions and explain the reasons and the creative process behind each. Readers will learn how to keep under control large-area technologies and achieve robust, reliable circuit designs that can face the challenges imposed by low-cost low-temperature high-throughput manufacturing.   • Discusses implications of problems associated with large-area electronics and compares them to standard silicon; • Provides the basis for understanding physics and modeling of disordered material; • Includes guidelines to quickly setup the basic CAD tools enabling efficient and reliable designs; • Illustrates practical solutions to cope with hard/soft faults, variability, mismatch, aging and bias stress at architecture, circuit, layout, and device levels.

  18. Hyaluronan-lecithin foils and their properties

    Energy Technology Data Exchange (ETDEWEB)

    BiaIopiotrowicz, Tomasz [Department of Interfacial Phenomena, Faculty of Chemistry, Maria Curie-SkIodowska University, Maria Curie-SkIodowska Square 3, 20-031 Lublin (Poland); Janczuk, BronisIaw [Department of Interfacial Phenomena, Faculty of Chemistry, Maria Curie-SkIodowska University, Maria Curie-SkIodowska Square 3, 20-031 Lublin (Poland); Fiedorowicz, Maciej [Department of Chemistry, Agricultural University of Krakow, Mickiewicz Ave., 21, 31 120 Cracow (Poland); Khachatryan, Gohar [Department of Chemistry, Agricultural University of Krakow, Mickiewicz Ave., 21, 31 120 Cracow (Poland); Tomasik, Piotr [Department of Chemistry, Agricultural University of Krakow, Mickiewicz Ave., 21, 31 120 Cracow (Poland)]. E-mail: rrtomasi@cyf-kr.edu.pl; Bakos, Dusan [Faculty of Chemical and Food Technology, Slovak Technical University, Radlinskeho 9, 812 37 Bratislava (Slovakia)

    2006-01-10

    Thin, elastic foils of good resistance to the air exposure, patented as wound healing aids, were prepared by evaporation of a blend of lecithin (L) and sodium hyaluronan (H) taken under varying proportions. The contact angle for water, glycerol, formamide, ethylene glycol and diiodomethane, was determined for these foils. The contact angle was correlated against the H:L foil composition. For all liquids but formamide the highest contact angle was noted for the H:L = 2:1 (g g{sup -1}) ratio. The contact angles provided estimation of the work of adhesion. At the same L:H ratio the work of adhesion was the lowest. It was suggested that lecithin cross-linked hyaluronan. Since the work of adhesion of the studied liquids was similar to that of diiodomethane, it could be concluded that almost all functional groups on the foil surface were completely blocked. Perhaps, at H:L = 2:1 (g g{sup -1}) a stoichiometric complex of hyaluronic acid with lecithin was formed, and polar functional groups from both reagents were involved. Foils seem to be electrostatic complexes of H with L. Foils with the H:L equal to 2:1 exhibited specific properties confirmed by the IR reflectance spectra of the foils. The thermogravimetry (TG/DTG) also revealed unique thermal behaviour confirming other specific properties of the foil of this composition. For the same ratio a thorough inspection of the scanning electron micrographs (SEM) revealed few irregularly distributed perforations of 1-2 {mu}m in diameter seen as black points, which can be recognized as pores. Properties of the foils determined in the contact angle measurements are nicely backed by the results from thermogravimetric and scanning electron microscopic studies.

  19. Hyaluronan-lecithin foils and their properties

    International Nuclear Information System (INIS)

    Thin, elastic foils of good resistance to the air exposure, patented as wound healing aids, were prepared by evaporation of a blend of lecithin (L) and sodium hyaluronan (H) taken under varying proportions. The contact angle for water, glycerol, formamide, ethylene glycol and diiodomethane, was determined for these foils. The contact angle was correlated against the H:L foil composition. For all liquids but formamide the highest contact angle was noted for the H:L = 2:1 (g g-1) ratio. The contact angles provided estimation of the work of adhesion. At the same L:H ratio the work of adhesion was the lowest. It was suggested that lecithin cross-linked hyaluronan. Since the work of adhesion of the studied liquids was similar to that of diiodomethane, it could be concluded that almost all functional groups on the foil surface were completely blocked. Perhaps, at H:L = 2:1 (g g-1) a stoichiometric complex of hyaluronic acid with lecithin was formed, and polar functional groups from both reagents were involved. Foils seem to be electrostatic complexes of H with L. Foils with the H:L equal to 2:1 exhibited specific properties confirmed by the IR reflectance spectra of the foils. The thermogravimetry (TG/DTG) also revealed unique thermal behaviour confirming other specific properties of the foil of this composition. For the same ratio a thorough inspection of the scanning electron micrographs (SEM) revealed few irregularly distributed perforations of 1-2 μm in diameter seen as black points, which can be recognized as pores. Properties of the foils determined in the contact angle measurements are nicely backed by the results from thermogravimetric and scanning electron microscopic studies

  20. Analysis of Mechanical Properties for GEM Foil

    CERN Document Server

    Chin, Yuk Ming

    2016-01-01

    In view of new assembly technique of the GEM detector; in which three foils stack is stretched to get the uniform gaps among the foils. We studied the mechanical properties of the foil material. We conditioned the samples in different environments to make them extra dry and wet. As holes are the major source of the charge amplification their deformation can effect the detector performance. Therefore in our studies we also studied at which level of the stress the holes deformation is seen. These tensile and holes deformation studies can help to optimize the stress during detector assembly.

  1. Tilted foils polarization at REX-ISOLDE

    CERN Document Server

    Tornqvist, H; Yordanov, D T; Imai, N; Heinz, A; Nilsson, T; Sotty, C; Hass, M; Georgiev, G; Johansson, H; Dhal, A; Stuchbery, A; Wenander, F; Hirayama, Y; Kusoglu, A; Balabanski, D

    2013-01-01

    The tilted-foils nuclear-spin polarization method has been evaluated using the REX-ISOLDE linear accelerator at the ISOLDE facility, CERN. A beam of Li-8 delivered with an energy of 300 keV/u traversed through one Mylar foil to degrade the beam energy to 200 keV/u and consequently through 10 thin diamond-like carbon foils to polarize the nuclear spin. The attained nuclear spin polarization of 3.6 +/- 0.3% was measured with a beta-NMR setup. (C) 2013 Elsevier B.V. All rights reserved.

  2. Endoluminal occlusion devices: technology update

    Directory of Open Access Journals (Sweden)

    Zander T

    2014-12-01

    Full Text Available Tobias Zander,1 Samantha Medina,1 Guillermo Montes,1 Lourdes Nuñez-Atahualpa,1 Michel Valdes,1 Manuel Maynar1,2 1Endoluminal/Vascular Department, Hospiten Hospital Group, Santa Cruz de Tenerife, 2University of Las Palmas de Gran Canarias, Las Palmas, Canary Island, Spain Abstract: Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices have been developed for changing conditions. Most of these occlusion devices have been implemented in the vascular territory. Early embolization materials included glass particles, hot contrast, paraffin, fibrin, and tissue fragments such as muscle fibers and blood clots; today, occlusion materials include metallic devices, particles, and liquid materials, which can be indicated for proximal or distal occlusion, high-flow and low-flow situations, and in large-caliber and small-caliber vessels, based on need. Technological progress has led to a decreased size of delivery catheters, and an increase in safety due to release systems that permit the withdrawing and replacement of embolization material. Furthermore, bioactive embolization materials have been developed to increase the efficacy of embolization or the biological effect of medication. Finally, materials have been modified for changing indications. Intravascular stents were initially developed to keep an artery open; however, by adding a covering membrane, these stents can be used to occlude the wall of a vessel or other endoluminal structures. This article gives an overview of the devices most utilized for occlusion of endoluminal structures, as well as their major purpose in the endovascular territory. Keywords: embolization, endovascular treatment, occlusion devices, hemorrhage, aneurysm, fistula

  3. Accident analysis for the NCSC foil experiment

    International Nuclear Information System (INIS)

    An accident analysis has been performed for the nuclear criticality safety class (NCSC) foil experiment. The Los Alamos Critical Experiments Facility (LACEF) performs this experiment regularly during its 2-, 3-, and 5-day nuclear criticality safety classes. This accident analysis is part of an effort to modify the NCSC foil experiment plan so that the experiment may be operated at delayed critical. Currently, the NCSC foil experiment may only be operated up to a neutron multiplication of 100. The purpose of the accident analysis is to ensure that any accidental nuclear excursion does not exceed the boundary of the safety envelope described in the LACEF safety analysis report (SAR). The experiment consists of very thin, highly enriched (93% 235U) uranium metal foils (23 X 23 X 0.008 cm) interleaved between Lucite plates (36 X 36 X 1.27 cm). The fuel foils and Lucite plates are stacked vertically to form a critical assembly. Extra Lucite plates placed at the top and bottom of the assembly act as vertical reflectors. The assembly is operated remotely with the use of a general-purpose vertical-lift platform machine. The accident scenario consists of one additional fuel foil being added to an existing critical or nearly critical stack. The reactivity insertion rate is 0.05 $/s, based on the speed of the vertical-lift platform. It is assumed that none of the safety systems will function properly during the accident and that the operating crew is unable to mitigate the accident

  4. Tungsten foil laminate for structural divertor applications – Analyses and characterisation of tungsten foil

    International Nuclear Information System (INIS)

    It has been attempted for several years to synthesise a tungsten material with a low brittle-to-ductile transition temperature and a high fracture toughness that can be used for structural parts. It was shown in our previous work that tungsten foil is ductile at room temperature and that this ductility can be transformed to bulk by synthesising a tungsten laminate. In this work we want to focus on tungsten foil and assess the microstructure as well as the mechanical properties of the foil. The assessment of the microstructure of 0.1 mm tungsten foil will be performed using electron microscopy. It will be shown that the grains of the tungsten foil have a dimension of 0.5 μm × 3 μm × 15 μm and a clear texture in (1 0 0) 〈0 1 1〉. This texture becomes even more pronounced by annealing. Three-point-bending tests with tungsten foil, as-received, will define the barriers: ductile at room temperature and brittle in liquid nitrogen (−196 °C). This shows that the ductility is a thermally activated process. Recrystallised tungsten foil (annealed for 1 h/2700 °C) shows ductile material behaviour at 200 °C. The paper closes with a discussion on the reasons of the ductility of 0.1 mm tungsten foil. These might be the ultra fine grained (UFG) microstructure or, in other words, a nano microstructure (see tungsten foil as-received), the high amount of mobile edge dislocations, and/or the foil effect, which means that dislocations can move to the surface and are annihilated (see tungsten foil recrystallised).

  5. Structured Occlusion Coding for Robust Face Recognition

    OpenAIRE

    Wen, Yandong; Liu, Weiyang; Yang, Meng; Fu, Yuli; Xiang, Youjun; Hu, Rui

    2015-01-01

    Occlusion in face recognition is a common yet challenging problem. While sparse representation based classification (SRC) has been shown promising performance in laboratory conditions (i.e. noiseless or random pixel corrupted), it performs much worse in practical scenarios. In this paper, we consider the practical face recognition problem, where the occlusions are predictable and available for sampling. We propose the structured occlusion coding (SOC) to address occlusion problems. The struct...

  6. Diagnostic advantages of making orthopantomograms in occlusion

    International Nuclear Information System (INIS)

    Orthopantomograms in occlusion proved to be of advantage in orthodontic diagnostics. Any disadvantages with regard to the imaging of the front sector are outweighed by decisive advantages, as e.g.: Midline displacements, infrapositions of teeth, frontal closed or deep occlusions, occlusal position and, to a certain extent, vertical hights of the jaws are reliably visualized in most cases. (orig./WU)

  7. Diagnostic advantages of making orthopantomograms in occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Fischer-Brandies, H.

    1985-01-01

    Orthopantomograms in occlusion proved to be of advantage in orthodontic diagnostics. Any disadvantages with regard to the imaging of the front sector are outweighed by decisive advantages, as e.g.: Midline displacements, infrapositions of teeth, frontal closed or deep occlusions, occlusal position and, to a certain extent, vertical hights of the jaws are reliably visualized in most cases.

  8. Orientation and alignment effects in beam foil experiments with tilted foils

    International Nuclear Information System (INIS)

    A general density matrix theory is formulated to account for recently observed orientation and alignment effects in beam foil experiments with tilted foils. Various simplified models for the interaction between the atomic and ionic excited states and the beam surface are considered and comparison with the present experimental data leads to some direct conclusions. Further experimental tests of the proposed mechanism are suggested. (author)

  9. Data processing code system for foil experiments

    International Nuclear Information System (INIS)

    A code system has been developed for an efficient measurement of reaction rates in foil irradiation experiments. The code system consists of four codes, namely of, (i) setting up experimental parameters and collecting γ-ray spectrum data, (ii) analysing γ-ray spectrum, (iii) calculating reaction rate distributions, and (iv) furnishing utility programs. This code system provides a useful tool of data processing of irradiated foil to obtain the γ-ray spectrum and the reaction rate distribution. These procedures can be executed automatically. The routine for processing foil counting data covers the following functions : the data smoothing, the peak searching by means of the first and second derivative methods, and the determination of the photo peak area and its error with use of a functional fitted by a non-linear least squares method. The code for reaction rate calculation has the following functions : the determination of decay constants of each isotope by using decay data of foil counting and the calculation of reaction rates after correcting irradiation time and weight of a foil. These codes are written by FORTRAN-77 for mini-computer PDP-11/44 (DEC), of which the maximum program memory size is limited to 32k bytes. (author)

  10. Tracking facial features with occlusions

    Institute of Scientific and Technical Information of China (English)

    MARKIN Evgeny; PRAKASH Edmond C.

    2006-01-01

    Facial expression recognition consists of determining what kind of emotional content is presented in a human face.The problem presents a complex area for exploration, since it encompasses face acquisition, facial feature tracking, facial expression classification. Facial feature tracking is of the most interest. Active Appearance Model (AAM) enables accurate tracking of facial features in real-time, but lacks occlusions and self-occlusions. In this paper we propose a solution to improve the accuracy of fitting technique. The idea is to include occluded images into AAM training data. We demonstrate the results by running ex periments using gradient descent algorithm for fitting the AAM. Our experiments show that using fitting algorithm with occluded training data improves the fitting quality of the algorithm.

  11. Cannabis, Collaterals, and Coronary Occlusion

    Directory of Open Access Journals (Sweden)

    Kalpa De Silva

    2011-01-01

    Full Text Available A 51-year-old gentleman, who regularly smoked cannabis, presented with chest pain and diaphoresis. He was haemodynamically stable. ECG showed ST depression, inferiorly, and 1 mm ST elevation in lead aVR. Emergent coronary angiography showed thrombotic occlusion of the left main coronary artery (LMCA, the dominant RCA provided Rentrop grade II collaterals to the LAD. The LMCA was successfully reopened by deployment of a bare-metal stent. Animal heart models suggest that endogenous cannibinoids may cause ischaemic preconditioning. This case suggests that the severity of ischaemia, and hence ECG changes and haemodynamic consequences following an acute occlusion of the LMCA, can be ameliorated by coronary collateralisation and possibly by preconditioning of the myocardium.

  12. Retinal vein occlusion: current treatment.

    Science.gov (United States)

    Lattanzio, Rosangela; Torres Gimeno, Ana; Battaglia Parodi, Maurizio; Bandello, Francesco

    2011-01-01

    Retinal vein occlusion (RVO) is a pathology noted for more than 150 years. Although a lot has been written on the matter, it is still a frequent condition with multifactorial etiopathogenesis with many unclear aspects. The RVO pathogenesis has varied systemic and local implications that make it difficult to elaborate treatment guidelines. The management of the patient with RVO is very complex and a multidisciplinary approach is required in order to identify and correct the associated risk factors. Laser therapy remains the gold standard in RVO, but only modest functional improvement has been shown in branch retinal occlusion forms. Multicenter studies of intravitreal drugs present them as an option to combine with laser. Anti-vascular endothelial growth factor, corticosteroids and sustained-release implants are the future weapons to stop disease progression and get a better visual outcome. Consequently, it is useful to clarify some aspects of the pathology that allow a better patient management. PMID:20938213

  13. Endoluminal occlusion devices: technology update

    OpenAIRE

    Zander, Tobias

    2014-01-01

    Tobias Zander,1 Samantha Medina,1 Guillermo Montes,1 Lourdes Nuñez-Atahualpa,1 Michel Valdes,1 Manuel Maynar1,2 1Endoluminal/Vascular Department, Hospiten Hospital Group, Santa Cruz de Tenerife, 2University of Las Palmas de Gran Canarias, Las Palmas, Canary Island, Spain Abstract: Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices h...

  14. Endoluminal occlusion devices: technology update

    OpenAIRE

    Zander T.; Medina S; Montes G; Nuñez-Atahualpa L; Valdes M; Maynar M

    2014-01-01

    Tobias Zander,1 Samantha Medina,1 Guillermo Montes,1 Lourdes Nuñez-Atahualpa,1 Michel Valdes,1 Manuel Maynar1,2 1Endoluminal/Vascular Department, Hospiten Hospital Group, Santa Cruz de Tenerife, 2University of Las Palmas de Gran Canarias, Las Palmas, Canary Island, Spain Abstract: Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices have ...

  15. Management of total restenotic occlusions.

    Science.gov (United States)

    Werner, Gerald S; Moehlis, Hiller; Tischer, Karlheinz

    2009-05-01

    Among lesions with in-stent restenosis (ISR), the in-stent chronic re-occlusions (ISR-CTO) is a subset with particularly unfavourable features regarding both the repeat procedure success and the prevention of lesion recurrence. A review of the literature and personal databases reveals that the prevalence of complete occlusive ISR represents about 5-10% of all CTO lesions, with little evidence regarding the successful long-term treatment. In fact, these lesions had been excluded from large contemporary trials dealing with the best modality for ISR management, and which showed eventually the superiority of drug-eluting stents (DES) as compared to brachytherapy. Only a limited experience exists with brachytherapy for ISR-CTOs, showing an inferior outcome as compared to non-occlusive ISRs. The lack of large study experience is true also for DES, so that only anecdotal experience in small series of patients is available. In some of the recent studies of DES in CTOs, again, ISR-CTOs were not included. Our own experience shows a slightly lower primary success rate of about 70% in ISR-CTOs as compared to 85% in primary CTOs, with a slightly higher recurrence rate with DES of 25%. ISR-CTOs are a clinical problem that had not been systematically addressed. However, we hope that this lesion subset may be of less relevance in the future when the use of DES in lesions which are prone for lesion recurrence will lead to less diffuse and occlusive ISR, and leaves rather focal and better manageable recurrent lesions. PMID:19736077

  16. Occlusal status among Yemeni children

    OpenAIRE

    Nabil M Al-Zubair; Ibrahim A Ghandour

    2014-01-01

    Objectives: The purpose of this study was to assess the occlusal status in schoolchildren in Yemen, and to compare the results with those of other studies. Materials and Methods: The sample for this epidemiological survey consisted of 3003 primary school students, half of whom were boys and the other half girls, aged 12 years. The subjects were randomly selected, and none had received previous orthodontic treatment. Variables examined included intra-arch irregularities and malalignment (crowd...

  17. Occlusal status among Yemeni children

    Directory of Open Access Journals (Sweden)

    Nabil M Al-Zubair

    2014-01-01

    Full Text Available Objectives: The purpose of this study was to assess the occlusal status in schoolchildren in Yemen, and to compare the results with those of other studies. Materials and Methods: The sample for this epidemiological survey consisted of 3003 primary school students, half of whom were boys and the other half girls, aged 12 years. The subjects were randomly selected, and none had received previous orthodontic treatment. Variables examined included intra-arch irregularities and malalignment (crowding and spacing in the incisal segments of the arch and midline diastema and discrepancies in occlusal contact relationship (maxillary overjet, mandibular overjet, anterior openbite and antero-posterior molar relation. Results: The results showed that about 26.1% of the subjects were still in the late mixed dentition stage and 73.9% presented with a dentition in the early permanent stage. Normal overjet was found in 55% of the sample. Crowding was observed in 31.4% of the subjects and midline diastema in 14.2%. Conclusion: Occlusal status among Yemeni children was characterized by a relatively high frequency of dental crowding, as well as a relatively high frequency of anterior mandibular overjet (Class III malocclusions.

  18. Compressor ported shroud for foil bearing cooling

    Science.gov (United States)

    Elpern, David G.; McCabe, Niall; Gee, Mark

    2011-08-02

    A compressor ported shroud takes compressed air from the shroud of the compressor before it is completely compressed and delivers it to foil bearings. The compressed air has a lower pressure and temperature than compressed outlet air. The lower temperature of the air means that less air needs to be bled off from the compressor to cool the foil bearings. This increases the overall system efficiency due to the reduced mass flow requirements of the lower temperature air. By taking the air at a lower pressure, less work is lost compressing the bearing cooling air.

  19. Making environmental sensors on plastic foil

    Directory of Open Access Journals (Sweden)

    Danick Briand

    2011-09-01

    Full Text Available With the emergence of the printed electronics industry, the development of sensing technologies on non conventional substrates such as plastic foils is on-going. In this article, we review the work performed and the trends in the development of environmental sensors on plastic and flexible foils. Our main focus is on the integration of temperature, humidity, and gas sensors on plastic substrates targeting low-power operation for wireless applications. Some perspectives in this dynamic field are also provided showing the potential for the realization of several types of transducers on substrates of different natures and their combination with other components to realize smart systems.

  20. Thrust augmentation in tandem flapping foils by foil-wake interaction

    Science.gov (United States)

    Anderson, Erik; Lauder, George

    2006-11-01

    Propulsion by pitching and heaving airfoils and hydrofoils has been a focus of much research in the field of biologically inspired propulsion. Organisms that use this sort of propulsion are self-propelled, so it is difficult to use standard experimental metrics such as thrust and drag to characterize performance. We have constructed a flapping foil robot mounted in a flume on air-bearings that allows for the determination of self-propelled speed as a metric of performance. We have used a pair of these robots to examine the impact of an upstream flapping foil on a downstream flapping foil as might apply to tandem fins of a swimming organism or in-line swimming of schooling organisms. Self-propelled speed and a force transducer confirmed significant thrust augmentation for particular foil-to-foil spacings, phase differences, and flapping frequencies. Flow visualization shows the mechanism to be related to the effective angle of attack of the downstream foil due to the structure of the wake of the upstream foil. This confirms recent computational work and the hypotheses by early investigators of fish fluid dynamics.

  1. Thermal characteristics of foils for an imaging bolometer

    International Nuclear Information System (INIS)

    The IR imaging video bolometer is an imaging bolometer which provides the intensity and distribution of plasma radiation. The sensitivity of the IR imaging bolometer is dependent on the properties of the bolometer foil. An evaluation of the thermal characteristics of various materials and thicknesses of the bolometer foil provides information on the sensitivity which is useful to choose the best foil material. We irradiated foils of various materials and thicknesses with a He-Ne laser (wavelength 633 nm), and measured the change in temperature distribution with an IR camera. As for foil materials,W, Ta, Au and Pt were employed. The foils were blackened either on both sides or on one side by graphite. For the same material foil, the temperature rise in the singleside blackened foil was always greater than the double-side blackened foil. For the double blacken foil, Ta had the largest temperature rise among foils with the same thickness. Pt had the shortest time constant for the temperature rise/decayamong foils except Au. In consideration of the attenuation thickness versus photon energy of each material, the Pt foil was the most suitable for the bolometer among the evaluated materials. (author)

  2. Tight, Flat, Smooth, Ultrathin Metal Foils for Locating Synchrotron Beams

    International Nuclear Information System (INIS)

    It is often desired to locate a synchrotron x-ray beam precisely in space with minimal disturbance of its spatial profile and spectral content. This can be done by passing the beam through an ultrathin, flat, smooth metal foil having well-defined composition, preferably a single chemical element such as chromium, titanium or aluminum. Localized fluorescence of the foil at characteristic x-ray lines where the x-ray beam passes through the foil serves to locate the beam in two dimensions. Use of two such foils along the beam direction locates the x-ray beam spatially and identifies precisely its direction. The accuracy of determining these parameters depends in part upon high uniformity in the thickness of the foil(s), good planarity, and smoothness of the foil(s). In practice, several manufacturing steps to produce a foil must be carried out with precision. The foil must be produced on a smooth removable substrate in such a way that its thickness (or areal density) is as uniform as possible. The foil must be fastened to a support ring that maintains the foil's surface quality, and it must be then stretched onto a frame that produces the desired mirror flatness. These steps are illustrated and some of the parameters specifying the quality of the resulting foils are identified

  3. 6Li foil thermal neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, Kiril D [Los Alamos National Laboratory; Swinhoe, Martyn T [Los Alamos National Laboratory; Favalli, Andrea [Los Alamos National Laboratory; Chung, Kiwhan [Los Alamos National Laboratory; Macarthur, Duncan W [Los Alamos National Laboratory

    2010-01-01

    In this paper we report on the design of a multilayer thermal neutron detector based on {sup 6}Li reactive foil and thin film plastic scintillators. The {sup 6}Li foils have about twice the intrinsic efficiency of {sup 10}B films and about four times higher light output due to a unique combination of high energy of reaction particles, low self absorption, and low ionization density of tritons. The design configuration provides for double sided readout of the lithium foil resulting in a doubling of the efficiency relative to a classical reactive film detector and generating a pulse height distribution with a valley between neutron and gamma signals similar to {sup 3}He tubes. The tens of microns thickness of plastic scintillator limits the energy deposited by gamma rays, which provides the necessary neutron/gamma discrimination. We used MCNPX to model a multilayer Li foil detector design and compared it with the standard HLNCC-II (18 {sup 3}He tubes operated at 4 atm). The preliminary results of the {sup 6}Li configuration show higher efficiency and one third of the die-away time. These properties, combined with the very short dead time of the plastic scintillator, offer the potential of a very high performance detector.

  4. The Fluid Foil: The Seventh Simple Machine

    Science.gov (United States)

    Mitts, Charles R.

    2012-01-01

    A simple machine does one of two things: create a mechanical advantage (lever) or change the direction of an applied force (pulley). Fluid foils are unique among simple machines because they not only change the direction of an applied force (wheel and axle); they convert fluid energy into mechanical energy (wind and Kaplan turbines) or vice versa,…

  5. Hot rolling of gamma titanium aluminide foil

    International Nuclear Information System (INIS)

    Metal flow and microstructure evolution during the thermomechanical processing of thin-gage foil of a near-gamma titanium aluminide alloy, Ti-45.5Al-2Cr-2Nb, with an equiaxed-gamma microstructure was investigated experimentally and theoretically. Foils of thickness of 200-250 μm were fabricated via hot rolling of sheet in a can of proprietary design. The variation in gage of the rolled foils was ±15 μm except in very sporadic (local) areas, with variations of approximately 60 μm relative to the mean. Metallography revealed that the larger thickness variations were associated with large remnant colonies lying in a hard orientation for deformation. To rationalize these observations, a self-consistent model was used to estimate the strain partitioning between the softer (equiaxed-gamma) matrix and the remnant colonies. Furthermore, the efficacy of pre- or post-rolling heat treatment in eliminating remnant colonies was demonstrated and quantified using a static-spheroidization model. The elimination of remnant colonies via spheroidization prior to foil rolling gave rise to improved gage control.

  6. Hydrogen and Palladium Foil: Two Classroom Demonstrations

    Science.gov (United States)

    Klotz, Elsbeth; Mattson, Bruce

    2009-01-01

    In these two classroom demonstrations, students observe the reaction between H[subscript 2] gas and Pd foil. In the first demonstration, hydrogen and palladium combine within one minute at 1 atm and room temperature to yield the non-stoichiometric, interstitial hydride with formula close to the maximum known value, PdH[subscript 0.7]. In the…

  7. Vortex wakes of a flapping foil

    DEFF Research Database (Denmark)

    Schnipper, Teis; Andersen, Anders Peter; Bohr, Tomas

    2009-01-01

    We present an experimental study of a symmetric foil performing pitching oscillations in a vertically flowing soap film. By varying the frequency and amplitude of the oscillation we visualize a variety of wakes with up to 46 vortices per oscillation period, including von Karman vortex street...

  8. Beryllium foils for windows in counter of nuclear radiation

    International Nuclear Information System (INIS)

    Based on the optimization of the main structural characteristics (grain structure, texture, dislocation substructure) are defined modes of deformation and heat treatment of beryllium foils (purity > 99.95%), providing their excellent mechanical properties and optimized modes of deformation and heat treatment. Analyzed various technological methods rolling foils to their rational use for the practical implementation of the results of the study. It is shown that the strength and plastic properties of the foils beryllium higher than that of similar foils foreign manufacture

  9. Branch Retinal Vein Occlusion and Its Management

    Institute of Scientific and Technical Information of China (English)

    Desmond; Archer

    1992-01-01

    The natural course of Branch Retinal Vein Occlusion is determined by the site and completeness of the occlusion, the integrity of arterial perfusion to the affected sector and the efficiency of the developing collateral circulation. Most patients with tributary vein occlusion have some capillary fall out and microvascular incompetence in the distribution of the affected retina and vision is significantly compromised in over 50% of patients who have either chronic macular oedema or ischemia involving the...

  10. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  11. Research and Development of GEM Foil at CIAE

    Institute of Scientific and Technical Information of China (English)

    LI; Xiao-mei; ZHOU; Jing; HU; Shou-yang; SHAN; Chao; JIAN; Si-yu; YE; Li; BAI; Xin-zhan; ZHOU; Shu-hua

    2012-01-01

    <正>China Institute of Atomic Energy has signed the "License Agreement for Manufacturing and Commercialisation of Gem Foils and Gem Based Products Licensee" with CERN, and got the technical assistance from CERN. The base material of GEM foil is ultrathin, non-adhesive copper on polyimide substrate, which can be purchased from CERN and other companies. The manufacture of GEM foil is

  12. A Numerical Calculation Model of Multi Wound Foil Bearing with the Effect of Foil Local Deformation

    Science.gov (United States)

    Feng, Kai; Kaneko, Shigehiko

    Foil bearings are supposed to be one of the best candidates of supporting component for turbo-machineries because of their design simplicity, reduced weight and size, high speed and temperature capability, and easy maintenance. Among various types of foil bearings, multi wound foil bearing (MWFB), which had been designed and fabricated in our lab, is easy to analyze static characteristics even though load capability of which is small compared with other types of foil bearings. In this study, a theoretical model of MWFB taking account of the effect of the foil deformation is developed to predict its static performance. Reynolds equation is solved using Finite Difference Method (FDM) to yield air pressure distribution, while the elastic deformation equation is solved by Finite Element Method (FEM) to predict the deformation of the foil. Then, the above two equations are coupled by several iterations until the convergence criterion is reached. Based on such calculations, static characteristics of MWFB such as load capacity, torque are presented.

  13. Non-Iris Occlusions Detection

    Czech Academy of Sciences Publication Activity Database

    Haindl, Michal; Krupička, Mikuláš

    Piscataway : IEEE, 2013, s. 1-6. ISBN 978-1-4799-0527-0. [The IEEE Sixth International Conference on Biometrics: Theory, Applications, and Systems (BTAS 2013). Washington DC (US), 29.09.2013-02.10.2013] R&D Projects: GA ČR GAP103/11/0335; GA ČR GA102/08/0593 Institutional support: RVO:67985556 Keywords : iris recognition * iris occlusion Subject RIV: BD - Theory of Information http://library.utia.cas.cz/separaty/2013/RO/haindl-0397243.pdf

  14. Nuclear target foil fabrication for the Romano Event

    International Nuclear Information System (INIS)

    The Vacuum Processes Lab, of LLNL's M.E. Dept. - Material Fabrication Division, was requested to provide 250 coated Parylene target foils for a nuclear physics experiment titled the ROMANO Event. Due to the developmental nature of some of the fabrication procedures, approximately 400 coated foils were produced to satisfy the event's needs. The foils were used in the experiment as subkilovolt x-ray, narrow band pass filters, and wide band ultraviolet filters. This paper is divided into three sections describing: (1) nuclear target foil fabrication, (2) Parylene substrate preparation and production, and (3) foil and substrate inspections

  15. Collodion-reinforcement and plasma-cleaning of target foils

    International Nuclear Information System (INIS)

    The preparation of evaporated target foils can often be facilitated by use of collodion coatings either on the substrate sides or on the exterior surfaces of the foils. Later, such coatings must usually be removed. Cleaning of a foil is necessary if thin layers of adhesives have crept onto the foil. Removal and/or cleaning can often be done satisfactorily with an oxygen plasma. Apparatus and procedures used for this are described. Foils that were cleaned successfully, and some that were incompatible with the cleaning process are listed

  16. Advances in targetry with thin diamond-like carbon foils

    CERN Document Server

    Liechtenstein, V K; Olshanski, E D; Repnow, R; Levin, J; Hellborg, R; Persson, P; Schenkel, T

    2002-01-01

    Thin and stable diamond-like carbon (DLC) foils, which were fabricated at the Kurchatov Institute by sputter deposition, have proved recently to be advantageous for stripping and secondary electron timing of high energy heavy ions in a number of accelerator experiments. This resulted in expanding applications of these DLC foils which necessitated further development efforts directed toward the following applications of DLC targetry: (i) thin stripper foils for lower energy tandem accelerators, (ii) enlarged (up to 66 mm in diameter) stop foils for improved time-of-flight elastic recoil detection ion beam analysis, and (iii) ultra-thin (about 0.6 mu g/cm sup 2) DLC foils for some fundamental and applied physics experiments. Along with the fabrication of thin DLC stripper foils for tandem accelerators, much thicker (up to 200 mu g/cm sup 2) foils for post-stripping of heavy-ion beams in higher energy linacs, are within reach.

  17. Impact of GEM foil hole geometry on GEM detector gain

    Science.gov (United States)

    Karadzhinova, A.; Nolvi, A.; Veenhof, R.; Tuominen, E.; Hæggström, E.; Kassamakov, I.

    2015-12-01

    Detailed 3D imaging of Gas Electron Multiplier (GEM) foil hole geometry was realized. Scanning White Light Interferometry was used to examine six topological parameters of GEM foil holes from both sides of the foil. To study the effect of the hole geometry on detector gain, the ANSYS and Garfield ++ software were employed to simulate the GEM detector gain on the basis of SWLI data. In particular, the effective gain in a GEM foil with equally shaped holes was studied. The real GEM foil holes exhibited a 4% lower effective gain and 6% more electrons produced near the exit electrode of the GEM foil than the design anticipated. Our results indicate that the GEM foil hole geometry affects the gain performance of GEM detectors.

  18. Expectations for the Laguna foil implosion experiments

    International Nuclear Information System (INIS)

    Building on the results achieved in the Pioneer shot series, the Los Alamos Trailmaster project is embarking on the Laguna foil implosion experiments. In this series a Mark-IX helical generator will be coupled to an explosively formed fuse opening switch, a surface-tracking closing switch, and a vacuum power flow and load chamber. In this paper the system design will be discussed and results from zero-, one-, and two-dimensional MHD simulations will be presented. It is anticipated that the generator will provide more than 10 MA of which ∼5.5 MA will be switched to the 5-cm-radius, 2-cm-high, 250-nm-thick aluminum foil load. This should give rise to a 1 μs implosion with more than 100 kJ of kinetic energy

  19. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Yohei, E-mail: ypfranky1@ybb.ne.jp [Department of Radiology, Niigata University Graduate School of Medical and Dental Science (Japan); Yoshimura, Norihiko [Department of Radiology, Niigata University Graduate School of Medical and Dental Science (Japan); Hori, Yoshiro [Department of Radiology, Showa University Fujigaoka Hospital (Japan); Horii, Yosuke; Ishikawa, Hiroyuki [Department of Radiology, Niigata University Graduate School of Medical and Dental Science (Japan); Yamazaki, Motohiko [Department of Radiology, Niigata City General Hospital (Japan); Noto, Yoshiyuki [Department of Radiology, Niigata University Medical and Dental Hospital (Japan); Aoyama, Hidefumi [Department of Radiology, Niigata University Graduate School of Medical and Dental Science (Japan)

    2014-12-15

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  20. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  1. Relativistic Electron Transport Through Carbon Foils

    Science.gov (United States)

    Seliger, M.; Takasi, K.; Reinhold, C. O.; Takabayashi, Y.; Ito, T.; Komaki, K.; Azuma, T.; Yamazaki, Y.; Yamazaki, Y.

    We present a theoretical study of convoy electron emission resulting from transmission of relativistic 390 MeV/amu Ar17+ ions through carbon foils of various thicknesses. Our approach is based on a Langevin equation describing the random walk of the electron initially bound to the argon nucleus and later in the continuum. The calculated spectra of ejected electrons in the forward direction exhibit clear signatures of multiple scattering and are found to be in good agreement with recent experimental data.

  2. Electrodeposition of Plutonium on Rhenium Foil

    Institute of Scientific and Technical Information of China (English)

    YANG; Jin-ling; YANG; Chun-li; DING; You-qian; SUN; Hong-qing

    2013-01-01

    Applying for LRIMS analysis,one of the main requirements is the production of an atomic beam(or molecular beam)with the atoms in one well defined state,i.e.,the ground state,and then the efficient excitation and ionization of the atoms.Therefore,the target nuclides must be transferred to the rhenium foil quantitatively.So the study on electrodeposistion was applied:first is the designation of electroplate

  3. Carbon nanotube thermal interfaces on gadolinium foil

    OpenAIRE

    McCarthy, Patrick T.; Marinero, Ernesto E.; Fisher, Timothy S.

    2012-01-01

    We report the thermal behavior of gadolinium foils to be used in magneto thermoelectric generator cells. Magneto thermoelectric generator cell technology exploits the ferromagnetic phase transition of gadolinium to drive the movement of a diaphragm 'shuttle' whose mechanical energy is converted to electrical form and which enhances heat transfer through both conduction and convection. Efficient heat transfer at mechanical interfaces is critical to increase shuttle speed and the commensurate r...

  4. Transport in a laser irradiated thin foil

    CERN Document Server

    Ruhl, H

    2001-01-01

    Three dimensional Particle-In-Cell simulations describing the interaction of a short intense laser pulse with thin foils are presented. It is observed that the laser generated electron current decays into magnetically isolated filaments. The filaments grow in scale and magnitude by reconnection. Two different laser wavelengths are considered. The spatial separation of the filaments varies for the two wavelengths. Many current filaments carry net electric currents exceeding the Alfven current considerably.

  5. Retinal vein occlusion: pathophysiology and treatment options

    OpenAIRE

    Karia, Niral

    2010-01-01

    Niral KariaDepartment of Ophthalmology, Southend Hospital, Prittlewell Chase, Westcliff on Sea, Essex, United KingdomAbstract: This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms.Keywords: central, hemispheric, branch, retinal vein occlusion, visual loss

  6. Retinal vein occlusion: pathophysiology and treatment options

    Directory of Open Access Journals (Sweden)

    Niral Karia

    2010-07-01

    Full Text Available Niral KariaDepartment of Ophthalmology, Southend Hospital, Prittlewell Chase, Westcliff on Sea, Essex, United KingdomAbstract: This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms.Keywords: central, hemispheric, branch, retinal vein occlusion, visual loss

  7. The prevalence of questionable occlusal caries

    DEFF Research Database (Denmark)

    Makhija, Sonia K; Gilbert, Gregg H; Funkhouser, Ellen;

    2012-01-01

    Questionable occlusal caries (QOC) can be defined as clinically suspected caries with no cavitation or radiographic evidence of occlusal caries. To the authors' knowledge, no one has quantified the prevalence of QOC, so this quantification was the authors' objective in conducting this study...

  8. Optical quality assurance of GEM foils

    International Nuclear Information System (INIS)

    An analysis software was developed for the high aspect ratio optical scanning system in the Detector Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5μm and 0.3μm, respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain mapping of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes

  9. The calculation program for activity correction by neutron incident on the edges of the foil in the foil activation method

    International Nuclear Information System (INIS)

    Computer program with FORTRAN has been made for calculating activity correction by neutron incident on the edge of the foil. The calculation based on single on collision theory with the assumption of monoenergetic neutron and isotopic distributed. the combination of simpson rule 1/3 and gauss quadrature were chosen to solve the problems and discrete summation was used as approximation of integration to the whole of energy groups (640 groups). the inputs are dimension and mass of the foil and activation cross-section and spectrum neutron. the output are foil activity and activation correction by neutron incident on the edge of the foil. the calculation results of activity correction by neutron incident on the edges of the gold foils of 0.05383 mm and 1.27 mm thick are about 0.2% and 7.8% and for cobalt foils of 0.1128 mm and 1.128 mm thick are about 0.58% and 6.7% respectively. the discrepancy of foil activation between experiment and calculation are about 1.6% for gold foil of 0.05383 mm thick and 1% for cobalt foil of 0.1128 mm thick. from that results can be concluded that the calculation result quit close to the experiment one and the thicker foil give bigger activation correction by neutrons incident on the edges of the foil

  10. Idiopathic pediatric retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Manayath George

    2010-01-01

    Full Text Available We report a case of branch retinal artery occlusion (BRAO in a healthy young girl. An eight-year-old girl presented with sudden loss of vision in her left eye. She had a pale retina with macular edema consistent with extensive BRAO. A thorough workup was performed to determine any etiologic factor. All test results were within normal limits. Her visual acuity improved from finger counting to 20/40 over two weeks, on immediate treatment with intravenous steroids (methyl prednisolone. This case suggests that BRAO can occur in healthy children without any detectable systemic or ocular disorders and a dramatic improvement may be achieved with prompt treatment with intravenous steroids.

  11. Monitoring the degradation of partly decomposable plastic foils

    Directory of Open Access Journals (Sweden)

    Rétháti Gabriella

    2014-11-01

    Full Text Available We have monitored the behaviour of different polyethylene foils including virgin medium density polyethylene (MDPE, MDPE containing pro-oxydative additives (238, 242 and MDPE with pro-oxydative additives and thermoplastic starch (297 in the soil for a period of one year. A foil based on a blend of polyester and polylactic acid (BASF Ecovio served as degradable control. The experiment was carried out by weekly measurements of conductivity and capacity of the soil, since the setup was analogous to a condenser, of which the insulating layer was the foil itself. The twelve replications allowed monthly sampling; the specimen taken out from the soil each month were tested visually for thickness, mechanical properties, morphological and structural changes, and molecular mass. Based on the obtained capacity values, we found that among the polyethylene foils, the one that contained thermoplastic starch extenuated the most. This foil had the greatest decrease in tensile strength and elongation at break due to the presence of thermoplastic starch. The starch can completely degrade in the soil; thus, the foil had cracks and pores. The polyethylene foils that contained pro-oxydant additives showed smaller external change compared to the virgin foil, since there was no available UV radiation and oxygen for their degradation. The smallest change occurred in the virgin polyethylene foil. Among the five examined samples, the commercially available BASF foil showed the largest extenuation and external change, and it deteriorated the most in the soil.

  12. Comparison of Au and Pt foils for an imaging bolometer

    International Nuclear Information System (INIS)

    The imaging bolometer is a fusion reactor relevant diagnostic for the measurement of radiated power. Essential to its ability to make accurate temporally and spatially resolved measurements of radiated power is the detailed calibration of the thin metal foil that converts the radiated power to infrared radiation measured by an infrared camera. The choice of the foil material is critical to optimizing the sensitivity of the imaging bolometer. Calibration of the foil provides information on the actual sensitivity of the foil which can help in selecting the best foil material. In this work thermal properties of the 0.63 micron thick Au and 0.87 micron thick Pt foils are investigated by heating the foils with a chopped 25 mW HeNe laser and observing the temperature change, ΔT, of the foil and the rise/decay times, τrise/decay, of the foil temperature. For a foil in which the cooling is dominated by diffusion, since the sensitivity of the foils is proportional to the ratio of the thermal diffusivity to the thermal conductivity of the foil, κ/k, which is proportional ΔT/τ, where τ is the average of the decay and rise times, we can compare the relative sensitivities of the foils by comparing these ratios for Pt and Au foils. The results surprisingly indicate that Pt is more than 9 times more sensitive than Au even though standard thermal properties indicate that Au should be 14% more sensitive than Pt. This inconsistency is largely due to a slightly smaller decay time, τ, which is inconsistent with a 5 times smaller κ, in the case of the Pt compared to Au. While the 5 -6 times larger temperature rise, ΔT, is somewhat consistent with 3.2 times smaller kt for the Pt foil compared to Au foil. This inconsistency in the thermal times, along with observed differences between the rise and decay times, indicate that the IR radiation is dominant over diffusion in the cooling of the foil. In that case the sensitivity should be evaluated by 1/k - ΔT which indicates that Pt

  13. Microfabricated Segmented-Involute-Foil Regenerator for Stirling Engines

    Science.gov (United States)

    Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gedeon, David; Qiu, Songgang; Wood, Gary; Kelly, Kevin; McLean, Jeffrey

    2010-01-01

    An involute-foil regenerator was designed, microfabricated, and tested in an oscillating-flow test rig. The concept consists of stacked involute-foil nickel disks (see figure) microfabricated via a lithographic process. Test results yielded a performance of about twice that of the 90-percent random-fiber currently used in small Stirling converters. The segmented nature of the involute- foil in both the axial and radial directions increases the strength of the structure relative to wrapped foils. In addition, relative to random-fiber regenerators, the involute-foil has a reduced pressure drop, and is expected to be less susceptible to the release of metal fragments into the working space, thus increasing reliability. The prototype nickel involute-foil regenerator was adequate for testing in an engine with a 650 C hot-end temperature. This is lower than that required by larger engines, and high-temperature alloys are not suited for the lithographic microfabrication approach.

  14. Effects of Aluminum Foil Packaging on Elemental Analysis of Bone.

    Science.gov (United States)

    Lewis, Lyniece; Christensen, Angi M

    2016-03-01

    Burned skeletal material is often very fragile and at high risk for fragmentation during packaging and transportation. One method that has been suggested to protect bones in these cases is to carefully wrap them in aluminum foil. Traces of aluminum, however, are known to transfer from foil packaging materials to food products. If such transfer occurs between aluminum foil and bones, it could interfere with subsequent chemical, elemental and isotopic analyses, which are becoming more common in forensic anthropological investigations. This study examined aluminum levels in bones prior to and following the use of aluminum foil packaging and storage for a 6-week period. Results indicate no significant change in the detected levels of aluminum (p > 0.05), even when packaged in compromised foil and exposed to elevated temperatures. Aluminum foil can therefore continue to be recommended as a packaging medium without affecting subsequent chemical examinations. PMID:27404616

  15. Carbon stripper foils for high current heavy ion operation

    International Nuclear Information System (INIS)

    For the proposed new heavy ion linac'at'GSI the installation of a carbon foil stripper section is under discussion. High duty factor as well as high current (but low duty factor) heavy ion beams were used for machine experiments. Long term tests were performed to check the carbon foil durability. Relevant beam parameters have been measured in three measurement campaigns. After beam testing stripper foils were analyzed with different offline methods. Additionally promising results of high current beam irradiation of rotating target wheels will be presented. In the transfer line to the SIS 18 the heavy ion beam is stripped to higher charge states in a thick carbon foil. The stripper foil is loaded with 3 % of the beam power. To avoid evaporation in a single beam pulse, the beam is rapidly swept over its width. Experiences collected during the last decade of foil stripper operation at GSI will be presented. (author)

  16. Optofluidic dye laser in a foil

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Christiansen, Mads Brøkner; Mappes, Timo; Kristensen, Anders

    2010-01-01

    First order distributed feedback optofluidic dye lasers embedded in a 350 mu m thick TOPAS (R) foil are demonstrated. They are designed in order to give high output pulse energies. Microfluidic channels and first order distributed feedback gratings are fabricated in parallel by thermal nanoimprint...... a large gain volume. Two grating periods of 185 nm and 190 nm yield single mode laser light emission at 566 nm and 581 nm respectively. High emitted pulse energies of more than 1 mu J are reported. Stable operation for more than 25 min at 10 Hz pulse repetition rate is achieved....

  17. Foil Diffuser Investigation with GEANT4

    CERN Document Server

    Fabritius, Joseph M; Walstrom, Peter

    2013-01-01

    An investigation into the appropriate materials for use as a diffuser foil in electron radiography was undertaken in GEANT4. Simulations were run using various refractory materials to determine a material of appropriate Z number such that energy loss is minimal. The plotted results of angular spread and energy spread are shown. It is concluded that higher Z number materials such as tungsten, tantalum, platinum or uranium could be used as diffuser materials. Also, an investigation into the handling of bremsstrahlung, multiple coulomb scattering, and ionization in GEANT4 was performed.

  18. The Los Alamos foil implosion project

    International Nuclear Information System (INIS)

    The goal of the Los Alamos foil implosion project is to produce an intense (>100 TW), multi-megajoule, laboratory soft x-ray source for material studies and fusion experiments. The concept involves the implosion of annular, current-carrying, cylindrical metallic plasmas via their self-magnetic forces. The project features inductive storage systems using both capacitor banks and high explosive-driven flux compression generators as prime energy sources. Fast opening switches are employed to shorten the electrical pulses. The program will be described and activities to date will be summarized

  19. Characterization of U-Mo Foils for AFIP-7

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Danny J.; Ermi, Ruby M.; Schemer-Kohrn, Alan L.; Overman, Nicole R.; Henager, Charles H.; Burkes, Douglas; Senor, David J.

    2012-11-07

    Twelve AFIP in-process foil samples, fabricated by either Y-12 or LANL, were shipped from LANL to PNNL for potential characterization using optical and scanning electron microscopy techniques. Of these twelve, nine different conditions were examined to one degree or another using both techniques. For this report a complete description of the results are provided for one archive foil from each source of material, and one unirradiated piece of a foil of each source that was irradiated in the Advanced Test Reactor. Additional data from two other LANL conditions are summarized in very brief form in an appendix. The characterization revealed that all four characterized conditions contained a cold worked microstructure to different degrees. The Y-12 foils exhibited a higher degree of cold working compared to the LANL foils, as evidenced by the highly elongated and obscure U-Mo grain structure present in each foil. The longitudinal orientations for both of the Y-12 foils possesses a highly laminar appearance with such a distorted grain structure that it was very difficult to even offer a range of grain sizes. The U-Mo grain structure of the LANL foils, by comparison, consisted of a more easily discernible grain structure with a mix of equiaxed and elongated grains. Both materials have an inhomogenous grain structure in that all of the characterized foils possess abnormally coarse grains.

  20. Fast-Neutron Surveys Using Indium-Foil Activation

    Energy Technology Data Exchange (ETDEWEB)

    Stephens, Lloyd D.; Smith, Alan R.

    1958-08-13

    Activation of indium foils by thermal neutrons has been applied to measurement of fast-neutron fluxes. Foils are encased in paraffin spheres placed in cadmium boxes. The high-energy neutrons that penetrate the cadmium become thermal neutrons; the thermal-neutron flux is proportional to the incident fast-neutron flux over a range of about 20 kev to 20 Mev. The foils are removed from the boxes and counted on a methane-flow proportional counter. High instantaneous neutron fluxes are easily detected and counted by use of these foils. Many simultaneous measurements have been made easily by this method.

  1. Thrombotic Occlusion during Intravascular Ultrasonography-Guided Percutaneous Coronary Intervention of Stumpless Chronic Total Occlusion

    OpenAIRE

    Lee, Un Joo; Kim, Hyun Soo; Lee, Cheolhyun; Kim, Kwang-yeol; Kim, Weon

    2014-01-01

    Percutaneous coronary intervention (PCI) of stumpless chronic total occlusion (CTO) lesions with a side branch stemming from the occlusion have a significantly lower treatment success rate because physicians cannot identify an accurate entry point with only conventional angiographic images. An intravascular ultrasonography (IVUS)-guided wiring technique might be useful for the penetration of stumpless CTO. We recently experienced thrombotic occlusion during an IVUS-guided stumpless CTO proced...

  2. Concurrent central retinal artery occlusion and branch retinal vein occlusion in giant cell arteritis

    OpenAIRE

    Chu, Edward

    2010-01-01

    Edward R Chu, Celia S ChenDepartment of Ophthalmology, Flinders Medical Centre and Flinders University, Bedford Park, SA, AustraliaAbstract: Ophthalmic involvement in giant cell arteritis can manifest in a number of ways. Central retinal artery occlusion is one of the common causes of visual loss in giant cell arteritis. On the contrary, branch retinal vein occlusion is rarely associated with the latter. We report an 89-year-old lady with acute left central retinal artery occlusion on a backg...

  3. Workflow Optimization in Vertebrobasilar Occlusion

    International Nuclear Information System (INIS)

    Objective: In vertebrobasilar occlusion, rapid recanalization is the only substantial means to improve the prognosis. We introduced a standard operating procedure (SOP) for interventional therapy to analyze the effects on interdisciplinary time management. Methods: Intrahospital time periods between hospital admission and neuroradiological intervention were retrospectively analyzed, together with the patients’ outcome, before (n = 18) and after (n = 20) implementation of the SOP. Results: After implementation of the SOP, we observed statistically significant improvement of postinterventional patient neurological status (p = 0.017). In addition, we found a decrease of 5:33 h for the mean time period from hospital admission until neuroradiological intervention. The recanalization rate increased from 72.2% to 80% after implementation of the SOP. Conclusion: Our results underscore the relevance of SOP implementation and analysis of time management for clinical workflow optimization. Both may trigger awareness for the need of efficient interdisciplinary time management. This could be an explanation for the decreased time periods and improved postinterventional patient status after SOP implementation.

  4. Retinal Artery Occlusion Treatment with Hyperbaric Oxygen

    Directory of Open Access Journals (Sweden)

    Harun Cakmak

    2016-01-01

    Full Text Available Retinal artery occlusion is one of the vision-threating emergency situations in ophthalmology. In this paper, a case of retinal artery occlusion is presented. Fifty seven year- old female patient presented with a sudden onset visual loss in her left eye. Best corrected visual acuity (BCVA levels were 1.0 and 0.7 in the right and left eye, respectiveley. Dilated fundus examination revealed no pathological finding in the right eye. Whereas calcified plaque was seen in upper arquat artery bifurcation in the left eye. Pallorness with retinal edema was seen in this arterial trace. Retinal artery occlusion was diagnosed and patient was referred for hyperbaric oxygen therapy. After a total of 20 sessions of hyperbaric oxygen therapy, the calcified plaques disappeared and her BCVA increased to 20/20. Hyperbaric oxygen treatment is vision-saving method which should be considered in retinal artery occlusion.

  5. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome

  6. Effect of glove occlusion on the skin barrier

    DEFF Research Database (Denmark)

    Tiedemann, Daniel; Clausen, Maja Lisa; John, Swen Malthe;

    2016-01-01

    that the negative effect of occlusion in itself is limited, and that only extensive and long-term occlusion will cause barrier impairment. However, studies investigating combined effect of occlusion and exposure to soaps/detergents indicate that occlusion significantly enhances the skin barrier damage...... caused by detergents/soaps in a dose-response fashion....

  7. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  8. Estimation of Absorbed Dose in Occlusal Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Young Ah; Choi, Karp Shick [Dept. of Oral Radiology, College of Dentistry, Kyungpuk National University, Daegu (Korea, Republic of); Lee, Sang Han [Dept. of Oral and Maxillofacial Surgery, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1990-02-15

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  9. Retinal vein occlusion in Benin City, Nigeria

    OpenAIRE

    Uhumwangho, Odarosa M.; Darlingtess Oronsaye

    2016-01-01

    Background: Retinal vein occlusion (RVO) is the most common occlusive retinal vascular disorder and results in varying degrees of visual loss. Aim: To determine the pattern of presentation, risk factors, and treatment outcomes in a group of patients with RVO seen in a tertiary hospital in Nigeria. Materials and Methods: Medical records of patients who presented to the University of Benin Teaching Hospital, Benin City, Nigeria in whom a diagnosis of RVO was made over a 5 years period were revi...

  10. Current possibilities in occlusal caries management

    Directory of Open Access Journals (Sweden)

    Hrvoje Jurić

    2013-11-01

    Full Text Available Dental caries is a multifactorial disease that affects most populations throughout the world and it is still the primary cause of oral pain and tooth loss. The occlusal surfaces of posterior teeth are the most vulnerable sites for dental caries due to their anatomy. Therefore, the aim of the following article is to summarize current knowledge on occlusal caries development and the possibilities of its prevention. Although the overall caries rate today has fallen for populations in industrialized countries, the rate of occlusal surface caries has not decreased. This may be explained with fact that topically applied fluorides and their mode of action prevent caries better on smooth than on occlusal surfaces. As we know, tooth decay of first permanent molars causes a great deal of different short and long term difficulties for patients. Therefore, there is a continuous need for implementation of programs for caries prevention in permanent teeth. Nowadays, we like to treat our patients by minimally invasive methods. A very important step in our effective preventive treatment is sealing pits and fissures as a cornerstone of occlusal caries management. Reliable assessment of caries activity is also very important for defining treatment needs and plans. A very important decision, which should be made during occlusal caries management, is the selection of restorative material according to the treatment plan. Conclusion. Current possibilities in occlusal caries prevention and management are very effective. Therefore, dentists today do not have any excuse for avoiding the philosophy of Minimally Invasive Dentistry, especially when we talk about caries management of occlusal surfaces in permanent molars.

  11. Branch retinal artery occlusion in Susac's syndrome

    Directory of Open Access Journals (Sweden)

    Ricardo Evangelista Marrocos de Aragão

    2015-02-01

    Full Text Available Susac's syndrome is a rare disease attribuited to a microangiopathy involving the arterioles of the cochlea, retina and brain. Encefalopathy, hearing loss, and visual deficits are the hallmarks of the disease. Visual loss is due to multiple, recurrent branch arterial retinal occlusions. We report a case of a 20-year-old women with Susac syndrome presented with peripheral vestibular syndrome, hearing loss, ataxia, vertigo, and vision loss due occlusion of the retinal branch artery.

  12. Current possibilities in occlusal caries management

    OpenAIRE

    Hrvoje Jurić

    2013-01-01

    Dental caries is a multifactorial disease that affects most populations throughout the world and it is still the primary cause of oral pain and tooth loss. The occlusal surfaces of posterior teeth are the most vulnerable sites for dental caries due to their anatomy. Therefore, the aim of the following article is to summarize current knowledge on occlusal caries development and the possibilities of its prevention. Although the overall caries rate today has fallen for populations in industriali...

  13. Epulis and pyogenic granuloma with occlusal interference

    Directory of Open Access Journals (Sweden)

    Widowati Witjaksono

    2005-06-01

    Full Text Available In dental clinic of Hospital University Science Malaysia (HUSM, there were cases with Localized Gingival Enlargement (LGE in the oral cavity with occlusal interference. In this study, three cases were observed. They were a 13 - year- old female with fibrous lge around 31 and 32 with occlusal interference in protrusive movement due to X bite, a 15 - year – old female with pyogenic granuloma near 11 & 21 with occlusal interference due to deep bite; and a 24 – year – old female who was eight months in pregnancy with pyogenic granuloma on the 34-35 and severe generalized pregnancy gingivitis with occlusal interference in centric occlusion and lateral movement. Clinical and histopathological diagnosis of the first case showed fibrous epulis, whereas the second and third cases disclosed pyogenic granuloma. Chronic trauma of the gingiva due to occlusal interference was assumed to be the cause of those LGE in case 1 and 2, while in case 3 poor oral hygiene and chronic trauma were assumed to be the etiologic factors.

  14. Actinide Foil Production for MPACT Research

    Energy Technology Data Exchange (ETDEWEB)

    Beller, Denis

    2012-10-30

    Sensitive fast-neutron detectors are required for use in lead slowing down spectrometry (LSDS), an active interrogation technique for used nuclear fuel assay for Materials Protection, Accounting, and Controls Technologies (MPACT). During the past several years UNLV sponsored a research project at RPI to investigate LSDS; began development of fission chamber detectors for use in LSDS experiments in collaboration with INL, LANL, and Oregon State U.; and participated in a LSDS experiment at LANL. In the LSDS technique, research has demonstrated that these fission chamber detectors must be sensitive to fission energy neutrons but insensitive to thermal-energy neutrons. Because most systems are highly sensitive to large thermal neutron populations due to the well-known large thermal cross section of 235U, even a miniscule amount of this isotope in a fission chamber will overwhelm the small population of higher-energy neutrons. Thus, fast-fission chamber detectors must be fabricated with highly depleted uranium (DU) or ultra-pure thorium (Th), which is about half as efficient as DU. Previous research conducted at RPI demonstrated that the required purity of DU for assay of used nuclear fuel using LSDS is less than 4 ppm 235U, material that until recently was not available in the U.S. In 2009 the PI purchased 3 grams of ultra-depleted uranium (uDU, 99.99998% 238U with just 0.2 ± 0.1 ppm 235U) from VNIIEF in Sarov, Russia. We received the material in the form of U3O8 powder in August of 2009, and verified its purity and depletion in a FY10 MPACT collaboration project. In addition, chemical processing for use in FC R&D was initiated, fission chamber detectors and a scanning alpha-particle spectrometer were developed, and foils were used in a preliminary LSDS experiment at a LANL/LANSCE in Sept. of 2010. The as-received U3O8 powder must be chemically processed to convert it to another chemical form while maintaining its purity, which then must be used to electro-deposit U

  15. Finding Temporally Consistent Occlusion Boundaries in Videos using Geometric Context

    OpenAIRE

    Raza, S. Hussain; Humayun, Ahmad; Grundmann, Matthias; Anderson, David,; Essa, Irfan

    2015-01-01

    We present an algorithm for finding temporally consistent occlusion boundaries in videos to support segmentation of dynamic scenes. We learn occlusion boundaries in a pairwise Markov random field (MRF) framework. We first estimate the probability of an spatio-temporal edge being an occlusion boundary by using appearance, flow, and geometric features. Next, we enforce occlusion boundary continuity in a MRF model by learning pairwise occlusion probabilities using a random forest. Then, we tempo...

  16. Preoperative risk assessment for carotid occlusion by transcranial Doppler ultrasound.

    OpenAIRE

    Schneweis, S; Urbach, H; Solymosi, L; Ries, F

    1997-01-01

    OBJECTIVES: An endovascular carotid balloon occlusion test with continuous intracranial monitoring by transcranial Doppler sonography was performed in 55 patients for prediction of tolerance of a required permanent occlusion of the carotid artery. METHODS: Blood flow velocities of the ipsilateral middle cerebral artery during occlusion were recorded and compared with clinical tolerance during an occlusion test as well as with postoperative outcome after an eventual permanent occlusion. To str...

  17. Gas amplification properties of GEM foils

    International Nuclear Information System (INIS)

    In the framework of the detector concept International Linear Detector for the future accelerator project International Linear Collider, in which electrons and positrons at c. m. energies of 500 GeV are brought to collision, a time projection chamber shall be applied as central track detector. By the application of such a chamber as track detector a three-dimensional reconstruction of the track points is possible. If a particle passes the gas volume within the chamber it ionizises single gas atoms and the arising electrons move after the amplification in the GEM arrangement to the anode, so that a two-dimensional projection of the particle track is possible. The third dimension is calculated from the drift time of the electrons. The advances of this readout system consist therein that a better position resolution than by a multiwire proportional chamber is reached and the back-drifting ions can be strongly suppressed. Aim of this thesis are studies for a GEM module, which shall be used in a large TPC prototype. Concerning different requirements it is valid to compare different GEMs in order to can meet an optimal choice. In a small prototype present at DESY measurements for the acquisition of GEM-describing parameters were performed. The taking into operation of the test TPC was part of this thesis. Tracks were generated by a radioactive source, by means of which the gas amplification was determined. With the measurement arrangement gas-amplifier foils of different kind were compared in view of their amplification properties and their energy resolution power and systematically studied. Five different GEM performances were studied in the test TPC. These foils differ in their geometrical classification parameters, the fabrication process, or the materials. The GEMs produced at CERN possess in comparison with GEMs of the Japanese firm SciEnergy and a GEM of the US-American firm Tech-Etch the best amplification and resolution properties. Furthermore a new GEM framing

  18. Lithographic patterning of metals on flexible plastic foils

    NARCIS (Netherlands)

    Peter, M.; Furthner, F.; Deen, J.; Laat, W.J.M.de; Meinders, E.R.

    2009-01-01

    In this paper the challenges of patterning electrodes with separations in the micron and sub-micron range onto thin polyethylene naphthalate foils for use in biochips are discussed. It was found that it was necessary to improve the adhesion of the metal electrodes to the foil by using plasma treatme

  19. Foil level packaging of a chemical gas sensor

    International Nuclear Information System (INIS)

    A generic method for the packaging of transducers at the foil level is proposed and was demonstrated on chemical gas sensors made on a plastic foil. The processing was based on the lamination of pre-patterned polymeric structures on the fabricated devices and covered by a gas permeable membrane. This polymeric packaging can be either applied on plastic foils or on conventional substrates such as silicon or glass. It can be used when standard packaging techniques might not be applied or when they can represent a significant cost. Using the lamination of a foil, the dry process presented here is compatible with large-scale fabrication techniques, such as roll-to-roll processing, and aims at reducing the global fabrication cost of sensing devices made on a plastic foil. It can further lead to the fabrication of all polymeric devices. This generic processing can be used for a wide range of applications in the field of microsystems, especially for which the foil level is required and where standard techniques at the wafer level are not applicable. The foil level packaging (FLP) was implemented here for the encapsulation of gas sensors on a plastic foil and validated through gas measurements.

  20. Foil fabrication for the ROMANO event. Revision 1

    International Nuclear Information System (INIS)

    The Vacuum Processes Lab (VPL), of LLNL's M.E. Dept. - Material Fabrication Division (MFD), conducted various vacuum related support activities for the ROMANO nuclear physics experiment. This report focuses on the foil fabrication activities carried out between July and November 1983 for the ROMANO event. Other vacuum related activities for ROMANO, such as outgassing tests of materials, are covered in separate documentation. VPL was asked to provide 270 coated Parylene foils for the ROMANO event. However, due to the developmental nature of some of the procedures, approximately 400 coated foils were processed. In addition, VPL interacted with MFD's Plastics Shop to help supply Parylene substrates to other organizations (i.e., LBL and commercial vendors) which had also been asked to provide coated foils for ROMANO. The purposes of this report are (A) to document the processes developed and the techniques used to produce the foils, and (B) to suggest future directions. The report is divided into four sections describing: (1) nuclear target foil fabrication, (2) Parylene substrate preparation and production, (3) calibration foil fabrication, and (4) foil and substrate inspections

  1. On the forced flow around a flapping foil

    CERN Document Server

    Mandujano, Francisco

    2016-01-01

    The two dimensional incompressible viscous flow past a flapping foil immersed in a uniform stream is studied numerically. Numerical simulations were performed using a Lattice-Boltzmann model for moderate Reynolds numbers. The computation of the hydrodynamic force on the foil is related to the the wake structure. In particular, when the foil's centre of mass is fixed in space, numerical results suggest a relation between drag coefficient behaviour and the flapping frequency which determines the transition from the von K\\'arm\\'an (vKm) to the inverted von K\\'arm\\'an wake. Beyond the inverted vKm transition the foil was released. Upstream swimming was observed at high enough flapping frequencies. Computed hydrodynamic forces suggest the propulsion mechanism for the swimming foil.

  2. Numerical and experimental investigation of bump foil mechanical behaviour

    DEFF Research Database (Denmark)

    Larsen, Jon Steffen; Cerda Varela, Alejandro Javier; Santos, Ilmar

    2014-01-01

    Corrugated foils are utilized in air foil bearings to introduce compliance and damping thus accurate mathematical predictions are important. A corrugated foil behaviour is investigated experimentally as well as theoretically. The experimental investigation is performed by compressing the foil......, between two parallel surfaces, both statically and dynamically to obtain hysteresis curves. The theoretical analysis is based on a two dimensional quasi static FE model, including geometrical non-linearities and Coulomb friction in the contact points and neglects the foil mass. A method for implementing...... the friction is suggested. Hysteresis curves obtained via the FE model are compared to the experimental results obtained. Good agreement is observed in the low frequency range and discrepancies for higher frequencies are thoroughly discussed....

  3. Compliant Foil Journal Bearings - Investigation of Dynamic Properties

    DEFF Research Database (Denmark)

    Larsen, Jon Steffen; Santos, Ilmar

    compliant foil bearings, and the understanding of their dynamic behaviour is growing. However, practical design involving these bearings are still associated with a large degree of trial and error. This study aims at establishing an accurate mathematical model, to calculate the pressure, film height and...... dynamic coefficients, of the compliant foil bearing together with an efficient solution method, which can be easily adopted and implemented by mechanical engineers. A theoretical model of a radial compliant foil bearing that incorporates compressibility of the lubricating gas and flexibility/compliance of...... the foil structure is presented. The compliance of the foil structure is incorporated implicitly in the Reynolds equation which is accomplished through a modification of the film gap function [8]. The resulting non-linear equation is perturbed and solved by use of the finite element method following a...

  4. Numerical analysis of bump foil bearings without nominal radial clearance

    Institute of Scientific and Technical Information of China (English)

    LIU Zhan-sheng; XU Huai-jin; ZHANG Guang-hui

    2008-01-01

    Bump foil bearings without nominal radial clearance were analyzed. An air film thickness model and a bearing theoretical analytical model were developed accounting for air compressibility and foil deformation. To analyze hydrodynamic characteristics of bump foil beatings with different operating eccentricities, the air film thickness equation and Reynolds equation were coupled through pressure and solved by Newton-Raphson Method(NRM) and Finite Difference Method (FDM). The characteristics of an bump foil bearing model were dis-cussed including load carrying capacity, film thickness and pressure distributions. The results of simulation show that bump foil beating without nominal radial clearance can provide better stability and greater load capaci-ty. This numerical analytical method also reveals a good convergence in numerical calculation.

  5. Freezing enhancement around a horizontal tube using copper foil disks

    Science.gov (United States)

    Sugawara, M.; Komatsu, Y.; Takahashi, Y.; Beer, H.

    2011-12-01

    Freezing of water saturated in circumferentially arranged copper foils around a cooling tube is studied experimentally and numerically. The copper foils need not to be welded to the cooling tube but are merely placed around the tube so that the freezing system is easily arranged. Copper foils greatly enhance freezing compared with that of a bare tube, even with a small copper volume fraction in the freezing system. Numerical calculations by means of a continuum model predict well freezing enhancement. The effect of the copper foils is also considered numerically for the melting process in order to compare with freezing. It is seen that copper foils contribute more to the melting enhancement than to the increase of the freezing rate.

  6. Foil calibration for IR imaging bolometer by laser irradiation

    International Nuclear Information System (INIS)

    The IR imaging video bolometer (IRVB) provides the power distribution of plasma radiation. The radiation distribution is obtained from the temperature distribution on the bolometer foil. It is necessary to calibrate between the temperature distribution and the incident radiation power on the bolometer foil. This paper describes a new calibration technique for the foil which we have developed. The bolometer foil was irradiated with a He-Ne laser and the temperature distribution was measured by an IR camera while changing the irradiation position. The temperature distribution measured was analyzed by the comparison with the results calculated by FEM. We repeated this comparison while changing the parameters such as effective foil thickness and effective emissivity in the calculation until the calculated distribution converged to the measured one. The temperature distribution calculated by the FEM agreed well with the measured one, so the calibration between the radiation power and the temperature profile can be suitably conducted by this technique. (author)

  7. Infrared imaging video bolometer with a double layer absorbing foil

    International Nuclear Information System (INIS)

    The object of the present paper is an infrared video bolometer with a bolometer foil consisting of two layers: the first layer is constructed of radiation absorbing blocks and the second layer is a thermal isolating base. The absorbing blocks made of a material with a high photon attenuation coefficient (gold) were spatially separated from each other while the base should be made of a material having high tensile strength and low thermal conductance (stainless steel). Such a foil has been manufactured in St. Petersburg and calibrated in NIFS using a vacuum test chamber and a laser beam as an incident power source. A finite element method (FEM) code was applied to simulate the thermal response of the foil. Simulation results are in good agreement with the experimental calibration data. The temperature response of the double layer foil is a factor of two higher than that of a single foil IR video bolometer using the same absorber material and thickness. (author)

  8. Quality Of Electrophotographic Prints On Foil Substrates

    Directory of Open Access Journals (Sweden)

    Rozália Szentgyörgyvölgyi

    2011-05-01

    Full Text Available Electrophotographic printing uses many types of substrates, our study focuses on plastic substrates. Six types ofregular and self-adhesive foil substrates were chosen to be printed using two electrophotographic presses: XeroxColour 1000 Press and Canon imagePress C7000VP. A test chart containing tone value scales and a set of samplesfor profiling was created, spectrophotomety and densitometry was applied to obtain the optical and colorimetricproperties of the substrates investigated. Xerox Color 1000 Press produced larger densities and tone value increaseon every type of substrate. The largest TVI values and reproducible colour gamut was observed on the smoothestfoil in case of both presses. Large colour differences were found between patches of full tone process colors on thedifferent substrates investigated.

  9. Bombarding insulating foils with highly energetic ions

    Science.gov (United States)

    Lanzanò, G.; de Filippo, E.; Hagmann, S.; Rothard, H.; Volant, C.

    Insulating (MYLAR), semi-insulating (MYLAR-Au) and conducting foils have been bombarded by very energetic 64 MeV u-1 78Kr32+ ions. The velocity spectra of fast electrons emitted in the backward and forward directions have been measured and analyzed as a function of the elapsed time in the run. A shift of binary encounter and convoy electrons emitted in the forward direction toward lower velocities has been observed with insulating targets. No such shift occurs with metallic targets. The surface potential evolves with time (i.e. ion fluence) both at forward and backward emission angle. It is shown that strong bulk charging of insulating targets leads to a positive potential as high as 9 kV before charge breakdown.

  10. Design considerations for foil windows for PET radioisotope targets

    International Nuclear Information System (INIS)

    This paper describes the results of a study performed at SRL to develop analytical and computational techniques for optimizing the design of conduction-cooled foil windows for PET targets. Single foil conduction cooled windows have been found to be good target entrance windows for both low energy accelerators and medium energy cyclotrons. Detailed thermal analysis has given an approximate analytical expression for the maximum temperature reached in a foil window under conditions of realistic ion beam bombardment. The effects of 'hot spots' in the beam density profile were investigated. It was shown that a factor of two safety margin in window design should be adequate to compensate for any possible beam hot spots. In addition, the reduction of foil stress by slack mounting was verified by experiments. The properties of conventional and novel foil materials were investigated for use in conduction cooled windows. Novel foil materials include two-component Al/Ti and Al/Havar foil. Results on the testing of candidate foil materials for thermal conductivity and mechanical strength at elevated temperature were presented. Two optimum foil window geometries were analyzed: a high aspect ratio window and a multiply slotted window. The multiply slotted window combines the advantages of a high aspect ratio foil window with a circular beam strike and is a promising window design for both TCA and cyclotron targets. A multiply slotted window for a N2 gas target for 15O production was designed using the methodologies discussed above. This prototype target was successfully tested using the TCA beam at SRL. (author) 6 figs., 3 tabs., 10 refs

  11. Foil Gas Thrust Bearings for High-Speed Turbomachinery

    Science.gov (United States)

    Edmonds, Brian; DellaCorte, Christopher; Dykas, Brian

    2010-01-01

    A methodology has been developed for the design and construction of simple foil thrust bearings intended for parametric performance testing and low marginal costs, supporting continued development of oil-free turbomachinery. A bearing backing plate is first machined and surface-ground to produce flat and parallel faces. Partial-arc slots needed to retain the foil components are then machined into the plate by wire electrical discharge machining. Slot thicknesses achievable by a single wire pass are appropriate to accommodate the practical range of foil thicknesses, leaving a small clearance in this hinged joint to permit limited motion. The backing plate is constructed from a nickel-based superalloy (Inconel 718) to allow heat treatment of the entire assembled bearing, as well as to permit hightemperature operation. However, other dimensionally stable materials, such as precipitation-hardened stainless steel, can also be used for this component depending on application. The top and bump foil blanks are cut from stacks of annealed Inconel X-750 foil by the same EDM process. The bump foil has several azimuthal slits separating it into five individual bump strips. This configuration allows for variable bump spacing, which helps to accommodate the effects of the varying surface velocity, thermal crowning, centrifugal dishing, and misalignment. Rectangular tabs on the foil blanks fit into the backing plate slots. For this application, a rather traditional set of conventionally machined dies is selected, and bump foil blanks are pressed into the dies for forming. This arrangement produces a set of bump foil dies for foil thrust bearings that provide for relatively inexpensive fabrication of various bump configurations, and employing methods and features from the public domain.

  12. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  13. Producing Foils From Direct Cast Titanium Alloy Strip

    Science.gov (United States)

    Stuart, T. A.; Gaspar, T. A.; Sukonnik, I. M.; Semiatan, S. L.; Batawi, E.; Peters, J. A.; Fraser, H. L.

    1996-01-01

    This research was undertaken to demonstrate the feasibility of producing high-quality, thin-gage, titanium foil from direct cast titanium strip. Melt Overflow Rapid Solidification Technology (MORST) was used to cast several different titanium alloys into 500 microns thick strip, 10 cm wide and up to 3 m long. The strip was then either ground, hot pack rolled or cold rolled, as appropriate, into foil. Gamma titanium aluminide (TiAl) was cast and ground to approximately 100 microns thick foil and alpha-2 titanium aluminide (Ti3AI) was cast and hot pack rolled to approximately 70 microns thick foil. CP Ti, Ti6Al2Sn4Zr2Mo, and Ti22AI23Nb (Orthorhombic), were successfully cast and cold-rolled into good quality foil (less than 125 microns thick). The foils were generally fully dense with smooth surfaces, had fine, uniform microstructures, and demonstrated mechanical properties equivalent to conventionally produced titanium. By eliminating many manufacturing steps, this technology has the potential to produce thin gage, titanium foil with good engineering properties at significantly reduced cost relative to conventional ingot metallurgy processing.

  14. Compliant Foil Journal Bearing Performance at Alternate Pressures and Temperatures

    Science.gov (United States)

    Bruckner, Robert J.; Puleo, Bernadette J.

    2008-01-01

    An experimental test program has been conducted to determine the highly loaded performance of current generation gas foil bearings at alternate pressures and temperatures. Typically foil bearing performance has been reported at temperatures relevant to turbomachinery applications but only at an ambient pressure of one atmosphere. This dearth of data at alternate pressures has motivated the current test program. Two facilities were used in the test program, the ambient pressure rig and the high pressure rig. The test program utilized a 35 mm diameter by 27 mm long foil journal bearing having an uncoated Inconel X-750 top foil running against a shaft with a PS304 coated journal. Load capacity tests were conducted at 3, 6, 9, 12, 15, 18, and 21 krpm at temperatures from 25 to 500 C and at pressures from 0.1 to 2.5 atmospheres. Results show an increase in load capacity with increased ambient pressure and a reduction in load capacity with increased ambient temperature. Below one-half atmosphere of ambient pressure a dramatic loss of load capacity is experienced. Additional lightly loaded foil bearing performance in nitrogen at 25 C and up to 48 atmospheres of ambient pressure has also been reported. In the lightly loaded region of operation the power loss increases for increasing pressure at a fixed load. Knowledge of foil bearing performance at operating conditions found within potential machine applications will reduce program development risk of future foil bearing supported turbomachines.

  15. Metabolic syndrome and central retinal artery occlusion

    OpenAIRE

    Kosanović-Jaković Natalija; Petrović Lidija; Risimić Dijana; Milenković Svetislav; Matić Danica

    2005-01-01

    Background. The accumulation of risk factors for central retinal artery occlusion can be seen in a single person and might be explained by the metabolic syndrome. Case report. We presented the case of a 52-year-old man with no light perception in his right eye. The visual loss was monocular and painless, fundoscopy showed central retinal artery occlusion and the laboratory investigation showed the raised erythrocyte sedimentation rate of 105 mm/h and the raised C-reactive protein of 22 mg/l. ...

  16. Common Carotid Artery Occlusion: A Case Series

    OpenAIRE

    Zoltán Bajkó; Rodica Bălaşa; Anca Moţăţăianu; Smaranda Maier; Octavia Claudia Chebuţ; Szabolcs Szatmári

    2013-01-01

    Subjects and Methods. We analysed 5000 cerebrovascular ultrasound records. A total of 0.4% of the patients had common carotid artery occlusion (CCAO). Results. The mean age was 59.8 ± 14.2 years, and the male/female ratio was 2.33. The most frequent risk factors were hypertension, ischaemic heart disease, dyslipidemia, diabetes mellitus, and smoking. Right-sided and left-sided CCAO occurred in 65% and 30% of the cases, respectively, and bilateral occlusion was detected in one case (5%). Paten...

  17. X-ray source production in foil implosion machines

    International Nuclear Information System (INIS)

    A number of two-dimensional radiation-magneto-hydrodynamic foil implosion calculations are discussed which explore ways of producing warm x-ray sources (∼60 eV) in a reproducible manner and which would permit close-in access to the source. The discussions include the effects of contoured electrodes on the foil implosion and source output, and of tapering the average mass distribution along the length of the foil. Primarily, source evaluation by jet formation and stagnation against a dense stopping block is treated

  18. Mechanical properties of micro- and nanocrystalline diamond foils.

    Science.gov (United States)

    Lodes, M A; Kachold, F S; Rosiwal, S M

    2015-03-28

    Diamond coating of suitable template materials and subsequent delamination allows for the manufacturing of free-standing diamond foil. The evolution of the microstructure can be influenced by secondary nucleation via control of process conditions in the hot-filament chemical vapour deposition process. Bending tests show extraordinarily high strength (more than 8 GPa), especially for diamond foils with nanocrystalline structure. A detailed fractographic analysis is conducted in order to correlate measured strength values with crack-initiating defects. The size of the failure causing flaw can vary from tens of micrometres to tens of nanometres, depending on the diamond foil microstructure as well as the loading conditions. PMID:25713455

  19. Tensile and Fatigue Properties of Free-Standing Cu Foils

    Institute of Scientific and Technical Information of China (English)

    Caiyun Dai; Xiaofei Zhu; Guangping Zhang

    2009-01-01

    Tensile and fatigue properties of free-standing as-rolled Cu foils were investigated by means of uniaxial tensile and dynamic bending tests. A special testing system was established to evaluate fatigue behavior of a mi-croscale material subjected to dynamic bending load. The experimental results show that the yield strength increases, but the fracture strain and fatigue resistance decrease with decreasing foil thickness. Deformation and fatigue damage behavior was characterized. The size effect on tensile and fatigue properties of the Cu foils are evaluated to get further understanding of the mechanical behavior of the micrometer-scale metallic materials.

  20. Elevated Temperature Tensile Tests on DU–10Mo Rolled Foils

    Energy Technology Data Exchange (ETDEWEB)

    Schulthess, Jason [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    Tensile mechanical properties for uranium-10 wt.% molybdenum (U–10Mo) foils are required to support modeling and qualification of new monolithic fuel plate designs. It is expected that depleted uranium-10 wt% Mo (DU–10Mo) mechanical behavior is representative of the low enriched U–10Mo to be used in the actual fuel plates, therefore DU-10Mo was studied to simplify material processing, handling, and testing requirements. In this report, tensile testing of DU-10Mo fuel foils prepared using four different thermomechanical processing treatments were conducted to assess the impact of foil fabrication history on resultant tensile properties.

  1. Thrombotic Occlusion during Intravascular Ultrasonography-Guided Percutaneous Coronary Intervention of Stumpless Chronic Total Occlusion.

    Science.gov (United States)

    Lee, Un Joo; Kim, Hyun Soo; Lee, Cheolhyun; Kim, Kwang-Yeol; Kim, Weon

    2014-12-01

    Percutaneous coronary intervention (PCI) of stumpless chronic total occlusion (CTO) lesions with a side branch stemming from the occlusion have a significantly lower treatment success rate because physicians cannot identify an accurate entry point with only conventional angiographic images. An intravascular ultrasonography (IVUS)-guided wiring technique might be useful for the penetration of stumpless CTO. We recently experienced thrombotic occlusion during an IVUS-guided stumpless CTO procedure. The cause of the thrombosis is not completely understood; the thrombosis may have been associated with the long use of the IVUS catheter. Special precautions should be taken to prevent thrombus in such cases. PMID:25568847

  2. Synchronization and Phase Dynamics of Oscillating Foils

    Science.gov (United States)

    Finkel, Cyndee L.

    In this work, a two-dimensional model representing the vortices that animals produce, when they are ying/swimming, was constructed. A D{shaped cylinder and an oscillating airfoil were used to mimic these body{shed and wing{generated vortices, respectively. The parameters chosen are based on the Reynolds numbers similar to that which is observed in nature (˜10 4). In order to imitate the motion of ying/swimming, the entire system was suspended into a water channel from frictionless air{bearings. The position of the apparatus in the channel was regulated with a linear, closed loop PI controller. Thrust/drag forces were measured with strain gauges and particle image velocimetry (PIV) was used to examine the wake structure that develops. The Strouhal number of the oscillating airfoil was compared to the values observed in nature as the system transitions between the accelerated and steady states. The results suggest that self-regulation restricts the values of the Strouhal number to a certain range where no other external sensory input is necessary. As suggested by previous work, this self-regulation is a result of a limit cycle process that stems from nonlinear periodic oscillations. The limit cycles were used to examine the synchronous conditions due to the coupling of the foil and wake vortices. Noise is a factor that can mask details of the synchronization. In order to control its effect, we study the locking conditions using an analytic technique that only considers the phases. Our results show that the phase locking indices are dependent on the Strouhal value as it converges to a frequency locking ratio of ≃0:5. This indicates that synchronization occurs during cruising between the motion of the foil and the measured thrust/drag response of the uid forces. The results suggest that Strouhal number selection in steady forward natural swimming and ying is the result of a limit cycle process and not actively controlled by an organism. An implication of this is

  3. Genetics Home Reference: pulmonary veno-occlusive disease

    Science.gov (United States)

    ... Understand Genetics Home Health Conditions pulmonary veno-occlusive disease pulmonary veno-occlusive disease Enable Javascript to view the ... Disease Control and Prevention: Pulmonary Hypertension Fact Sheet Disease InfoSearch: Pulmonary venoocclusive ... pulmonary venoocclusive disease Orphanet: Pulmonary ...

  4. International 235U fission foil mass intercomparison

    International Nuclear Information System (INIS)

    In the measurement of neutron fission cross sections, one of the larger uncertainties is associated with the mass determination of the fissionable deposit. Inconsistencies in determinations of the fission cross sections may be a result of systematic errors associated with the measurement of the deposit mass. As part of a study to check the consistency of mass scales at a number of laboratories throughout the world, two 235U deposits from the Khlopin Radium Institute (KRI) in Leningrad, USSR, were made available through the assistance of the International Atomic Energy Agency for measurements at the National Bureau of Standards (NBS) and Argonne National Laboratory (ANL). These deposits are directly traceable to foils used in very precise measurements of the 235U(n,f) cross section made in a collaborative effort by KRI and the Technical University of Dresden (TUD), GDR. The study undertaken at the NBS consisted of two parts. One part was the measurement of the alpha-decay rates of the two 235U samples (KRI VI and KRI-XV) with a low-geometry-counting spectrometry facility. The other was the measurement of the total alpha disintegration rate of the samples employing a 2II alpha counter

  5. Class II malocclusion occlusal severity description

    Directory of Open Access Journals (Sweden)

    Guilherme Janson

    2010-08-01

    Full Text Available OBJECTIVES: It is well known that the efficacy and the efficiency of a Class II malocclusion treatment are aspects closely related to the severity of the dental anteroposterior discrepancy. Even though, sample selection based on cephalometric variables without considering the severity of the occlusal anteroposterior discrepancy is still common in current papers. In some of them, when occlusal parameters are chosen, the severity is often neglected. The purpose of this study is to verify the importance given to the classification of Class II malocclusion, based on the criteria used for sample selection in a great number of papers published in the orthodontic journal with the highest impact factor. MATERIAL AND METHODS: A search was performed in PubMed database for full-text research papers referencing Class II malocclusion in the history of the American Journal of Orthodontics and Dentofacial Orthopedics (AJO-DO. RESULTS: A total of 359 papers were retrieved, among which only 72 (20.06% papers described the occlusal severity of the Class II malocclusion sample. In the other 287 (79.94% papers that did not specify the anteroposterior discrepancy severity, description was considered to be crucial in 159 (55.40% of them. CONCLUSIONS: Omission in describing the occlusal severity demands a cautious interpretation of 44.29% of the papers retrieved in this study.

  6. Clinical Practice Guidelines for intestinal occlusion.

    OpenAIRE

    Rudis Miguel Monzón Rodríguez; Carlos Jaime Geroy Gómez; Francisco García Valdéz; Jorge Luis Ulloa Capestany; Maribel Misas Menéndez

    2009-01-01

    Clinical Practice Guidelines for intestinal occlusion. This document includes the main aspects related with classification, physiopathology, clinical diagnosis, complementary examinations and therapy aimed at the post-operatory treatment. It includes assessment guidelines focused on the most important aspects to be accomplished.

  7. Virtual occlusal definition for orthognathic surgery.

    Science.gov (United States)

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate. PMID:26701322

  8. Occlusion Culling and Hardware Accelerated Volume Rendering

    OpenAIRE

    Meissner, Michael

    2000-01-01

    Within this dissertation, a set of algorithmic optimizations are developed, enabling significant performance improvements due to a much better utilization of the available bandwidth. Additionally, new architectural concepts circumventing the bottle-necks of currently available general purpose graphics hardware are presented. In the field of polygon rendering, a unique mechanism for hardware supported occlusion queries to cull geometry prior to geometry transformation --- sav...

  9. Chronic coronary occlusions: age, morphology and chance of reopening.

    OpenAIRE

    Vallbracht, C; Unverdorben, M; Kadel, C; Oster, H; J. Otto; Kober, G; Kaltenbach, M

    1997-01-01

    In chronic coronary occlusions the chance of successful reopening by angioplasty can be judged from the age of the occlusion. Often, however, time since occlusion cannot be accurately assessed. Therefore we determined whether the chance of reopening can be predicted from angiographic morphology. In cineangiograms from 60 consecutive patients with chronic coronary occlusions morphological details in at least two projections were evaluated in relation to the rate of success and the estimated ag...

  10. Different Occlusal Schemes in a Persistent Protruding Complete Denture Wearer

    OpenAIRE

    Carolina Mayumi Iegami; Danilo de Melo Lopes; Atlas Edson Moleros Nakamae; Priscila Nakasone Uehara; Regina Tamaki

    2016-01-01

    Different types of artificial teeth and occlusal designs can be used in complete dentures. Bilateral balanced occlusion, lingualized occlusion, canine guidance, and monoplane are the main occlusal designs; however there is no agreement on which tooth arrangement is ideal for achieving success in complete dentures. This report presents an alternative for persistent involuntary protruding complete denture wearers through the use of artificial teeth with higher cusps. Due to an old and worn pair...

  11. Foil Gas Bearing Supported Quiet Fan for Spacecraft Ventilation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Developing a quiet fan for Environmental Control and Life Support systems to enhance the livable environment within the spacecraft has been a challenge. A Foil Gas...

  12. Decontamination with pasty pickling agents forming a strippable foil

    International Nuclear Information System (INIS)

    This paper describes the development of an in-situ decontamination procedure by applying onto the contaminated surface (in an one-step or multi-step process) pasty, chemically aggressive agents causing dilution and adsorption of the contaminant and then hardening to form a strippable foil. The use of such a foil will result in following advantages, with respect to usual techniques: - sensibly shorter operation duration resulting in lower personnel doses; - reduction of the arising secondary waste volume because there is no need for washing; the volume of the spent strippable foil is much smaller than currently used water volumes; - optimal conditioning of the radioactive waste due to its fixation in a solid (foil); - an accidental contamination in a controlled area can easily be fixed and covered avoiding its propagation

  13. Stratification in Al and Cu foils exploded in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Baksht, R. B. [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk 634055 (Russian Federation); Electrical Discharge and Plasma Laboratory, Tel Aviv University, Tel Aviv 6997801 (Israel); Rousskikh, A. G.; Zhigalin, A. S.; Artyomov, A. P. [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk 634055 (Russian Federation); Oreshkin, V. I. [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk 634055 (Russian Federation); National Research Tomsk Polytechnic University, Tomsk 634050 (Russian Federation)

    2015-10-15

    An experiment with exploding foils was carried out at a current density of 0.7 × 10{sup 8} A/cm{sup 2} through the foil with a current density rise rate of about 10{sup 15} A/cm{sup 2} s. To record the strata arising during the foil explosions, a two-frame radiographic system was used that allowed tracing the dynamics of strata formation within one shot. The original striation wavelength was 20–26 μm. It was observed that as the energy deposition to a foil stopped, the striation wavelength increased at a rate of ∼(5–9) × 10{sup 3} cm/s. It is supposed that the most probable reason for the stratification is the thermal instability that develops due to an increase in the resistivity of the metal with temperature.

  14. Controlled electropolishing of copper foils at elevated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Gi Duk; Kim, Young Woo; Moyen, Eric; Keum, Dong Hoon [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Lee, Young Hee [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); IBS Center for Integrated Nanostructure Physics (CINAP), Institute of Basic Science (IBS), Daejeon (Korea, Republic of); Department of Physics, Sungkyunkwan Advanced Institute of Nano-technology (SAINT), Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Baik, Seunghyun [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); School of Mechanical Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); IBS Center for Integrated Nanostructure Physics (CINAP), Institute of Basic Science (IBS), Daejeon (Korea, Republic of); Pribat, Didier, E-mail: didier53@skku.edu [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2014-07-01

    We have studied the electrochemical polishing of copper foils at elevated temperature, in H{sub 3}PO{sub 4} electrolytes of various concentrations. Atomic force microscopy, surface reflectance measurements as well as optical microscopy and scanning electron microscopy (including electron backscattering diffraction) have been used throughout this study to characterize the surface of the electropolished foils. We have found that copper foils electropolished at 65 °C in 2.17 M H{sub 3}PO{sub 4}, exhibited a lower surface roughness and a higher percent specular reflection, comparing with values obtained after classical electropolishing in concentrated H{sub 3}PO{sub 4} at room temperature or comparing with values obtained after chemical-mechanical polishing. This work could open up new prospects for the preparation of copper foils before the growth of high quality graphene layers.

  15. Method of stabilizing Nb3Sn superconducting foils

    International Nuclear Information System (INIS)

    The stabilization of niobium-tin Nb3Sn superconducting foils with copper is carried out by deposition or by diffusion in pure copper or in a tin bath containing different copper levels, with the surface etched or unetched. The foils are covered with a copper film at a temperature of 300 to 5O0 degC using a tin solder, spread on a copper, silver or nickel layer deposited on the foil surface from solutions for electroless plating. The bond between the surface of the superconducting foil and the electroless plated metal layer is annealed in a controlled atmosphere or in a vacuum at a temperature of 200 to 500 degC for over 20 to 60 minutes. The copper stabilization layer can also be produced electrolytically. (J.B.)

  16. Design of foil implosion system for Pioneer I experiments

    International Nuclear Information System (INIS)

    A foil implosion system is described that integrates an explosive flux-compression generator, a flat plate feed section with power conditioning switches, and a vacuum electrode region containing a cylindrical foil/plasma load. Power conditioning, obtained with an explosive-driven plasma compression opening switch and explosive-actuated closing switches, provides a submicrosecond multimegampere pulse for the implosion of an aluminum plasma. The flat plate section is configured for bidirectional feed to the coaxial vacuum electrodes. Important considerations in the design of the vacuum power flow region include gap failure, feed symmetry, and radial diagnostic access. The system presently accommodates a foil radius of 3 cm. Innovative foil insertion and clamping techniques are also described

  17. Parent Artery Occlusion for Posterior Cerebral Artery Aneurysms

    OpenAIRE

    Hoya, K.; Nagaishi, M.; Yoshimoto, Y.; Morikawa, E.; H. Takahashi(NASA Goddard Space Flight Center, Greenbelt, USA)

    2006-01-01

    We review four cases of posterior cerebral artery (PCA) aneurysm, of which three showed intolerance of parent artery occlusion. In two, balloon test occlusion (BTO) indicated poor opaci- fication of the PCA branches from the anastomoses, and therefore, permanent occlusion was not attempted.

  18. 21 CFR 870.2890 - Vessel occlusion transducer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vessel occlusion transducer. 870.2890 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2890 Vessel occlusion transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an...

  19. 21 CFR 880.5950 - Umbilical occlusion device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Umbilical occlusion device. 880.5950 Section 880.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5950 Umbilical occlusion device. (a) Identification. An umbilical occlusion device is a...

  20. Material Properties of Laser-Welded Thin Silicon Foils

    OpenAIRE

    Brabec, C.J.; Auer, R.; A. Bochmann; Christiansen, S.; Schmidt, M.; K. Cvecek; Voigt, M.; Hessmann, M. T.; Kunz, T.

    2013-01-01

    An extended monocrystalline silicon base foil offers a great opportunity to combine low-cost production with high efficiency silicon solar cells on a large scale. By overcoming the area restriction of ingot-based monocrystalline silicon wafer production, costs could be decreased to thin film solar cell range. The extended monocrystalline silicon base foil consists of several individual thin silicon wafers which are welded together. A comparison of three different approaches to weld 50 μm thin...

  1. Practical and research aspects of beam-foil spectroscopy

    International Nuclear Information System (INIS)

    The application of a heavy-ion accelerator to research in beam-foil spectroscopy requires certain capital equipment which is somewhat unorthodox when viewed from the standpoint of conventional, low-energy nuclear physics. It is necessary that people who wish to expand their accelerator work to include beam-foil studies understand the nature and cost of such major apparatus. We will survey the equipment needs, starting with the particle analyzer at the output of the accelerator and including the equipment used in a variety of beam-foil experiments. Electronic and computer devices will not be discussed since they are essentially identical with those employed in nuclear studies. Considerable attention will be given to optical spectrometers and spectographs including simple instruments which might be used by a laboratory just getting started in beam-foil research, or which has limited financial resources. Attention will be given to the production and use of the exciter foils. We will then discuss some typical beam-foil experiments having to do with the excitation, detection, and analysis of spectral lines from electronic levels in multiply-ionized atoms, and also with the measurement of the mean lives of such levels. Finally, we will review some of the special properties of the beam-foil light source as regards the population of the magnetic sub-states of a given level. Recent work on the character of the emitted light will be presented. That work will deal specifically with the origin of the polarization of the light. The relevant experiments involve varying the angle between the plane of the exciter foil and the particle velocity. (author)

  2. Analysis of the Caudal Vortices Evolvement around Flapping Foil

    Institute of Scientific and Technical Information of China (English)

    Wang Zhi-dong; Zhang Xiao-qing; Su Yu-min; Xu Yu-ru

    2005-01-01

    The viscous flow field around two-dimensional flapping (heaving and pitching) foils was numerically computed. The structural characteristics of caudal vortices were investigated and the contour curves at different phase angles were obtained.The relationships between the structural characteristics of the vortices and the force acting on the foil and between the widths of the caudal vortex street and of the caudal flow field were analyzed. A method to determine the shedding frequency of the vortices was proposed.

  3. PS-OCT of occlusal and interproximal caries lesions viewed from occlusal surfaces

    Science.gov (United States)

    Ngaotheppitak, Patara; Darling, Cynthia L.; Fried, Daniel; Bush, Jeff; Bell, Steve

    2006-02-01

    Previous studies have demonstrated that Polarization Sensitive Optical Coherence Tomography (PS-OCT) can be used to image early dental caries. The primary objective of this study was to compare the measured reflectivity of natural occlusal caries lesions with the relative mineral loss measured using digital microradiography. There was excellent agreement between the increase in the integrated reflectivity in the perpendicular polarization axis of the PS-OCT system and the increase in the integrated mineral loss or lesion severity for occlusal lesions. Therefore, PS-OCT is ideally suited to image natural caries lesions in the important occlusal surfaces for the assessment of the lesion severity and activity. A secondary objective was to compare the performance of a new autocorrelator-based PS-OCT system employing a novel polarization-switching probe with our polarization-maintaining fiber based PS-OCT system, both operating at 1310-nm. The new PS-OCT system produced clean images with no artifacts and achieved high penetration depth. Yet a third objective was to determine if interproximal lesions can be imaged from the occlusal surface (from above) since interproximal lesions may only be accessible in vivo from buccal or lingual surfaces or from the occlusal surface. Simulated and natural interproximal caries lesions were imaged from the occlusal surfaces as long as there was no intervening dentin.

  4. Globally shed wakes for three distinct retracting foil geometries

    Science.gov (United States)

    Steele, Stephanie; Triantafyllou, Michael

    2015-11-01

    In quickly retracting foils at an angle of attack, the boundary layer vorticity along with the added mass energy is immediately and globally shed from the body into the surrounding fluid. The deposited vorticity quickly reforms into lasting vortex structures, which could be used for purposes such as manipulating or exploiting the produced flow structures by additional bodies in the fluid. The globally shed wake thus entrains the added mass energy provided by the initially moving body, reflected by the value of the circulation left in the wake. In studying experimentally as well as numerically this phenomenon, we find that the three different tested geometries leave behind distinct wakes. Retracting a square-ended foil is undesirable because the deposited wake is complicated by three-dimensional ring vorticity effects. Retracting a tapered, streamlined-tipped foil is also undesirable because the shape-changing aspect of the foil geometry actually induces energy recovery back to the retracting foil, leaving a less energetic globally shed wake. Finally, a retracting hollow foil geometry avoids both of these detrimental effects, leaving relatively simple, yet energetic, vortex structures in the wake.

  5. Propulsion of a flexible foil in a fluid

    Science.gov (United States)

    Venkatraman, Kartik; Chaithanya, Ravi

    2008-11-01

    The dynamic properties such as time dependent pressure loading, free stream velocity, and local acceleration of the hydrofoil determine the instantaneous deformation of a flexible foil. The present work is concerned with the effect of structural dynamic terms and inertia loads on a flexible foil undergoing large amplitude rigid body harmonic wave-like motion in an unsteady potential flow. The hydrofoil structural dynamics is modeled as an Euler-Bernoulli beam finite element. The unsteady fluid dynamic force is evaluated using a numerical discrete vortex implementation of an unsteady incompressible potential flow model. The hydrofoil is fixed at its leading edge and it moves with velocity parallel to its length in the undeformed state. The propulsion of the hydro-elastic system is studied in terms of the mass ratio of the foil and the fluid, as well as its structural flexibility. It is shown that the thrust coefficient and propulsive efficiency of the flexible foil decreases with increase in structural flexibility. We made a comparison of the effect of structural flexibility on the thrust coefficient and propulsive efficiency considering models of the oscillating foil with inertia and without inertia effects present. Detailed parametric studies of the effect of different parameters on propulsion of the foil were made. Including inertia loads and structural dynamic terms significantly affect the propulsive efficiency and thrust coefficient.

  6. Research and Development of Commercially Manufactured Large GEM Foils

    CERN Document Server

    Posik, M

    2014-01-01

    The recently completed Forward GEM Tracker (FGT) of the STAR experiment at RHIC took advantage of commercially produced GEM foils based on double-mask chemical etching techniques. With future experiments proposing detectors that utilize very large-area GEM foils, there is a need for commercially available GEM foils. Double-mask etching techniques pose a clear limitation in the maximum size. In contrast, single-mask techniques developed at CERN would allow one to overcome those limitations. We report on results obtained using 10 $\\times$ 10 cm$^2$ and 40$\\times$40 cm$^2$ GEM foils produced by Tech-Etch Inc. of Plymouth, MA, USA using single-mask techniques and thus the beginning for large GEM foil production on a commercial basis. A quality assurance procedure has been established through electrical and optical analyses via leakage current measurements and an automated high-resolution CCD scanner. The Tech-Etch foils show excellent electrical properties with leakage currents typically measured below 1 nA. The ...

  7. Aluminum clad ferritic stainless steel foil for metallic catalytic converter substrate applications

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.S.; Pandey, A.; Jha, B.

    1996-09-01

    A roll bonding process was developed to produce Al clad ferritic stainless steel foil for the metallic catalytic converter substrate application. Clad foils with different chemistry were produced and their properties were evaluated. Heat treatment conditions for the homogenization of clad foils were identified. This article includes results from oxidation tests and mechanical tests on as-rolled and heat treated clad foil. Results from commercial ingot metallurgy foil were also included for comparison. The oxidation weight gain study indicates that the Al content in the foils is directly related to the usable life of the foil. However, rare earth addition is necessary to improve the oxidation resistance of this material for the high temperature applications by slowing down the weight gain kinetics and thus extend the usable life of foils. The heat treated clad foil also exhibit excellent tensile ductility when compared to the ingot metallurgy foil.

  8. Occlusion Handling in Videos Object Tracking: A Survey

    International Nuclear Information System (INIS)

    Object tracking in video has been an active research since for decades. This interest is motivated by numerous applications, such as surveillance, human-computer interaction, and sports event monitoring. Many challenges related to tracking objects still remain, this can arise due to abrupt object motion, changing appearance patterns of objects and the scene, non-rigid object structures and most significant are occlusion of tracked object be it object-to-object or object-to-scene occlusions. Generally, occlusion in object tracking occur under three situations: self-occlusion, inter-object occlusion by background scene structure. Self-occlusion occurs most frequently while tracking articulated objects when one part of the object occludes another. Inter-object occlusion occurs when two objects being tracked occlude each other whereas occlusion by the background occurs when a structure in the background occludes the tracked objects. Typically, tracking methods handle occlusion by modelling the object motion using linear and non-linear dynamic models. The derived models will be used to continuously predicting the object location when a tracked object is occluded until the object reappears. Example of these method are Kalman filtering and Particle filtering trackers. Researchers have also utilised other features to resolved occlusion, for example, silhouette projections, colour histogram and optical flow. We will present some result from a previously conducted experiment when tracking single object using Kalman filter, Particle filter and Mean Shift trackers under various occlusion situation in this paper. We will also review various other occlusion handling methods that involved using multiple cameras. In a nutshell, the goal of this paper is to discuss in detail the problem of occlusion in object tracking and review the state of the art occlusion handling methods, classify them into different categories, and identify new trends. Moreover, we discuss the important

  9. Woodgrain defect on tinned steel Flandres foil

    International Nuclear Information System (INIS)

    Tin electrocoated steel strip, also referred to as Flandres foil, is largely used for manufacturing food containers. Tinplates must have good corrosion resistance, workability, weldability, as well as a bright appearance. The woodgrain defect, a not yet fully understood defect that occurs on tinplates and accounts for their high scrap rate, consists of alternate bands of bright/dull reflectivity and resembles longitudinally cut wood. Observations of the woodgrain defect by scanning electron microscopy showed that the molten tin spreads irregularly during both the melting and solidification stages. X-ray diffraction analyses showed that the metallic tin tended to crystallize in the (200) direction for coupons with and without the woodgrain defect. Nevertheless, the preferential orientation degree decreased for coupons with the woodgrain defect. The rocking curves, also known as omega-scan, showed that the tin grains were uniformly aligned parallel to the strip surface for coupons with no defects, whereas for tinplates with woodgrain, the tin grains were not uniformly oriented, probably due to the misalignment of the grains in relation to the surface. - Graphical abstract: The woodgrain defect occurs on Flandres tinplates and consists in the formation of alternate bands of different reflectivity (bright/dull), which looks like longitudinally cut wood. X-ray diffractometry showed that the typical bright surface of tinplate is associated to the uniform distribution of aligned (200) Sn grains, whereas in tinplate with the woodgrain defect, the Sn grains were not uniformly oriented, due to the misalignment of the (200) Sn planes relative to the surface. Research highlights: → The bright surface of tinplate is associated to the uniform distribution of aligned (200) Sn grains. → The woodgrain defect on tinplate consists in alternate bands of bright/dull appearance. → In tinplate with the woodgrain defect, the Sn grains were not uniformly oriented, due to the

  10. Dental Occlusion Influences the Standing Balance on an Unstable Platform.

    Science.gov (United States)

    Julià-Sánchez, Sonia; Álvarez-Herms, Jesús; Gatterer, Hannes; Burtscher, Martin; Pagès, Teresa; Viscor, Ginés

    2015-10-01

    Contradictory results are still reported on the influence of dental occlusion on the balance control. We attempted to determine whether there are differences in balance between opposed dental occlusion (Intercuspal position (ICP)/"Cotton rolls" mandibular position [CR]) for two extreme levels of stability (stable/ unstable). Twenty-five subjects were monitored under both dental occlusion and level of stability conditions using an unstable platform Balance System SD. The resulting stability index suggests that body balance is significantly better when dental occlusion is set in CR (p crowding (p = .006), midline deviation (p dental occlusion for the balance control comes strongly into effect in unstable conditions. PMID:25674772

  11. Performance of Simple Gas Foil Thrust Bearings in Air

    Science.gov (United States)

    Bruckner, Robert J.

    2012-01-01

    Foil bearings are self-acting hydrodynamics devices used to support high speed rotating machinery. The advantages that they offer to process fluid lubricated machines include: high rotational speed capability, no auxiliary lubrication system, non-contacting high speed operation, and improved damping as compared to rigid hydrodynamic bearings. NASA has had a sporadic research program in this technology for almost 6 decades. Advances in the technology and understanding of foil journal bearings have enabled several new commercial products in recent years. These products include oil-free turbochargers for both heavy trucks and automobiles, high speed electric motors, microturbines for distributed power generation, and turbojet engines. However, the foil thrust bearing has not received a complimentary level of research and therefore has become the weak link of oil-free turbomachinery. In an effort to both provide machine designers with basic performance parameters and to elucidate the underlying physics of foil thrust bearings, NASA Glenn Research Center has completed an effort to experimentally measure the performance of simple gas foil thrust bearing in air. The database includes simple bump foil supported thrust bearings with full geometry and manufacturing techniques available to the user. Test conditions consist of air at ambient pressure and temperatures up to 500 C and rotational speeds to 55,000 rpm. A complete set of axial load, frictional torque, and rotational speed is presented for two different compliant sub-structures and inter-pad gaps. Data obtained from commercially available foil thrust bearings both with and without active cooling is presented for comparison. A significant observation made possible by this data set is the speed-load capacity characteristic of foil thrust bearings. Whereas for the foil journal bearing the load capacity increases linearly with rotational speed, the foil thrust bearing operates in the hydrodynamic high speed limit. In

  12. A Microfabricated Involute-Foil Regenerator for Stirling Engines

    Science.gov (United States)

    Tew, Roy; Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gedeon, David; Kelly, Kevin; McLean, Jeffrey; Qiu, Songgang

    2007-01-01

    A segmented involute-foil regenerator has been designed, microfabricated and tested in an oscillating-flow rig with excellent results. During the Phase I effort, several approximations of parallel-plate regenerator geometry were chosen as potential candidates for a new microfabrication concept. Potential manufacturers and processes were surveyed. The selected concept consisted of stacked segmented-involute-foil disks (or annular portions of disks), originally to be microfabricated from stainless-steel via the LiGA (lithography, electroplating, and molding) process and EDM. During Phase II, re-planning of the effort led to test plans based on nickel disks, microfabricated via the LiGA process, only. A stack of nickel segmented-involute-foil disks was tested in an oscillating-flow test rig. These test results yielded a performance figure of merit (roughly the ratio of heat transfer to pressure drop) of about twice that of the 90 percent random fiber currently used in small approx.100 W Stirling space-power convertors-in the Reynolds Number range of interest (50 to 100). A Phase III effort is now underway to fabricate and test a segmented-involute-foil regenerator in a Stirling convertor. Though funding limitations prevent optimization of the Stirling engine geometry for use with this regenerator, the Sage computer code will be used to help evaluate the engine test results. Previous Sage Stirling model projections have indicated that a segmented-involute-foil regenerator is capable of improving the performance of an optimized involute-foil engine by 6 to 9 percent; it is also anticipated that such involute-foil geometries will be more reliable and easier to manufacture with tight-tolerance characteristics, than random-fiber or wire-screen regenerators. Beyond the near-term Phase III regenerator fabrication and engine testing, other goals are (1) fabrication from a material suitable for high temperature Stirling operation (up to 850 C for current engines; up to 1200 C

  13. Interaction of relativistic H- ions with thin foils

    International Nuclear Information System (INIS)

    The response of relativistic H- ions to thin carbon foils was investigated for beam energies ranging from 226 MeV to 800 MeV. For the foil thicknesses we have studied, ranging from 15 to 300 μg/cm2, an appreciable fraction of the H- beam survives intact, some H- ions are stripped down to protons, and the remainder is distributed over the states of H0. This experiment is different from the low energy studies in that the projectile velocity is comparable to the speed of light, leading to an interaction time of typically less than a femtosecond. The present results challenge the theoretical understanding of the interaction mechanisms. An electron spectrometer was used to selectively field-ionize the Rydberg states, 9 < n < 17, at beam energies of 581 MeV and 800 MeV. The yield of low-lying states were measured by Doppler tuning a Nd:YAG laser to excite transitions to a Rydberg state which was then field-ionized and detected. A simple model is developed to fit the yield of each state as a function of foil thickness. The simple model is successful in predicting the general features of the yield data. However, the data are suggestive of a more complex structure in the yield curves. The yield of a given state depends strongly on the foil thickness, demonstrating that the excited states are formed during the passage of the ions through a foil. The optimum thickness to produce a given state increases with the principal quantum number of the state suggesting an excitation process which is at least pratially stepwise. The results of a Monte Carlo simulation are compared with the experimental data to estimate the distribution of the excited states coming out of a foil. The distributions of the excited states and their dependence on foil thickness are discussed

  14. Nontraumatic vascular emergencies: imaging and intervention in acute venous occlusion

    International Nuclear Information System (INIS)

    Risk factors for acute venous occlusion range from prolonged immobilization to hypercoagulability syndromes, trauma, and malignancy. The aim of this review article is to illustrate the different imaging options for the diagnosis of acute venous occlusion and to assess the value of interventional strategies for venous thrombosis treatment in an emergency setting. First, diagnosis and treatment of the most common form of venous occlusion, at the level of the lower extremities, is presented, followed by pelvic vein and inferior vena cava occlusion, mesenteric venous thrombosis, upper extremity occlusion, acute cerebral vein thrombosis, and finally acute venous occlusion of hemodialysis access. In acute venous occlusion of the lower extremity phlebography is still the reference gold standard. Presently, duplex ultrasound with manual compression is the most sensitive and specific noninvasive test. Limitations of ultrasonography include isolated distal calf vein occlusion, obesity, and patients with lower extremity edema. If sonography is nondiagnostic, venography should be considered. Magnetic resonance venography can differentiate an acute occlusion from chronic thrombus, but because of its high cost and limited availability, it is not yet used for the routine diagnosis of lower extremity venous occlusion only. Regarding interventional treatment, catheter-directed thrombolysis can be applied to dissolve thrombus in charily selected patients with symptomatic occlusion and no contraindications to therapy. Acute occlusion of the pelvic veins and the inferior vena cava, often due to extension from the femoropopliteal system, represents a major risk for pulmonary embolism. Color flow Doppler imaging is often limited owing to obesity and bowel gas. Venography has long been considered the gold standard for identifying proximal venous occlusion. Both CT scanning and MR imaging, however, can even more accurately diagnose acute pelvis vein or inferior vena cava occlusion. MRI is

  15. Photometric Ambient Occlusion for Intrinsic Image Decomposition.

    Science.gov (United States)

    Hauagge, Daniel; Wehrwein, Scott; Bala, Kavita; Snavely, Noah

    2016-04-01

    We present a method for computing ambient occlusion (AO) for a stack of images of a Lambertian scene from a fixed viewpoint. Ambient occlusion, a concept common in computer graphics, characterizes the local visibility at a point: it approximates how much light can reach that point from different directions without getting blocked by other geometry. While AO has received surprisingly little attention in vision, we show that it can be approximated using simple, per-pixel statistics over image stacks, based on a simplified image formation model. We use our derived AO measure to compute reflectance and illumination for objects without relying on additional smoothness priors, and demonstrate state-of-the art performance on the MIT Intrinsic Images benchmark. We also demonstrate our method on several synthetic and real scenes, including 3D printed objects with known ground truth geometry. PMID:26959670

  16. Handling Occlusions for Robust Augmented Reality Systems

    Directory of Open Access Journals (Sweden)

    Maidi Madjid

    2010-01-01

    Full Text Available Abstract In Augmented Reality applications, the human perception is enhanced with computer-generated graphics. These graphics must be exactly registered to real objects in the scene and this requires an effective Augmented Reality system to track the user's viewpoint. In this paper, a robust tracking algorithm based on coded fiducials is presented. Square targets are identified and pose parameters are computed using a hybrid approach based on a direct method combined with the Kalman filter. An important factor for providing a robust Augmented Reality system is the correct handling of targets occlusions by real scene elements. To overcome tracking failure due to occlusions, we extend our method using an optical flow approach to track visible points and maintain virtual graphics overlaying when targets are not identified. Our proposed real-time algorithm is tested with different camera viewpoints under various image conditions and shows to be accurate and robust.

  17. RTSAH Traversal Order for Occlusion Rays

    KAUST Repository

    Ize, Thiago

    2011-04-01

    We accelerate the finding of occluders in tree based acceleration structures, such as a packetized BVH and a single ray kd-tree, by deriving the ray termination surface area heuristic (RTSAH) cost model for traversing an occlusion ray through a tree and then using the RTSAH to determine which child node a ray should traverse first instead of the traditional choice of traversing the near node before the far node. We further extend RTSAH to handle materials that attenuate light instead of fully occluding it, so that we can avoid superfluous intersections with partially transparent objects. For scenes with high occlusion, we substantially lower the number of traversal steps and intersection tests and achieve up to 2× speedups. © 2010 The Author(s).

  18. Tracking multiple mice through severe occlusions

    OpenAIRE

    Branson, Kristin

    2007-01-01

    In this thesis, I address the problem of tracking multiple identical mice through severe occlusions from video of a side of their cage. A solution to this problem would greatly benefit medical research because of the key role animal testing plays in medical research. As the majority of visual tracking algorithms are intended for tracking people or cars, they are not directly applicable to the mouse tracking problem. Mice are extremely deformable, unconstrained three-dimensional objects. They ...

  19. Crossing Total Occlusions: Navigating Towards Recanalization.

    Science.gov (United States)

    Sakes, Aimée; Regar, Evelyn; Dankelman, Jenny; Breedveld, Paul

    2016-06-01

    Chronic total occlusions (CTOs) represent the "last frontier" of percutaneous interventions. The main technical challenges lies in crossing the guidewire into the distal true lumen, which is primarily due to three problems: device buckling during initial puncture, inadequate visualization, and the inability to actively navigate through the CTO. To improve the success rate and to identify future research pathways, this study systematically reviews the state-of-the-art of all existing and invented devices for crossing occlusions. The literature search was executed in the databases of Scopus and Espacenet using medical and instrument-related keyword combinations. The search yielded over 840 patents and 69 articles. After scanning for relevancy, 45 patents and 16 articles were included. The identified crossing devices were subdivided based on the determinant for the crossing path through the occlusion, which is either the device (straight and angled crossing), the environment (least resistance, tissue selective, centerline, and subintimal crossing) or the user (directly steered and sensor enhanced crossing). It was found that each crossing path is characterized by specific advantages and disadvantages. For a future crossing device, a combination of crossing paths is suggested were the interventionist is able to exert high forces on the CTO (as seen in the device approach) and actively steer through the CTO (user: directly steered crossing) aided by intravascular imaging (user: sensor enhanced crossing) or an intrinsically safe device following the centerline or path of least resistance (environment: centerline crossing or least resistance crossing) to reach the distal true lumen. PMID:26831298

  20. Laser photocoagulation for retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    K. A. Mirzabekova

    2015-03-01

    Full Text Available Retinal vein occlusion (RVO is one of the leading causes of permanent vision loss. In adults, central retinal vein occlusion (CRVO occurs in 1.8% while branch retinal vein occlusion (BRVO occurs in 0.2%. Treatment strategy and disease prognosis are determined by RVO type (ischemic/non-ischemic. Despite numerous studies and many current CRVO and BRVO treatment approaches, the management of these patients is still being debated. Intravitreal injections of steroids (triamcinolone acetate, dexamethasone and vascular endothelial growth factor (VEGF inhibitors (bevacizumab, ranibizumab were shown to be fairly effective. However, it is unclear whether anti-VEGF agents are reasonable in ischemic RVOs. Laser photocoagulation remains the only effective treatment of optic nerve head and/or retinal neovascularization. Laser photocoagulation is also indicated for the treatment of macular edema. Both threshold and sub-threshold photocoagulation may be performed. Photocoagulation performed with argon (514 nm, krypton (647 nm, or diode (810 nm laser for macular edema provides similar results (no significant differences. The treatment may be complex and include medication therapy and/or surgery. Medication therapy includes anti-aggregant agents and antioxidants, i.e., emoxypine which may be used in acute RVO as well as in post-thrombotic retinopathy. 

  1. Gas Foil Bearings for Space Propulsion Nuclear Electric Power Generation

    Science.gov (United States)

    Howard, Samuel A.; DellaCorte, Christopher

    2006-01-01

    The choice of power conversion technology is critical in directing the design of a space vehicle for the future NASA mission to Mars. One candidate design consists of a foil bearing supported turbo alternator driven by a helium-xenon gas mixture heated by a nuclear reactor. The system is a closed-loop, meaning there is a constant volume of process fluid that is sealed from the environment. Therefore, foil bearings are proposed due to their ability to use the process gas as a lubricant. As such, the rotor dynamics of a foil bearing supported rotor is an important factor in the eventual design. The current work describes a rotor dynamic analysis to assess the viability of such a system. A brief technology background, assumptions, analyses, and conclusions are discussed in this report. The results indicate that a foil bearing supported turbo alternator is possible, although more work will be needed to gain knowledge about foil bearing behavior in helium-xenon gas.

  2. Foil implosion studies with a plasma flow switch

    International Nuclear Information System (INIS)

    A plasma flow switch has been developed for the 1.5 MJ Pegasus capacitor bank to efficiently utilize the bank energy to drive a foil implosion. The object of this activity is to generate an intense burst of soft x-rays when the foil stagnates and thermalizes on axis. The peak current of the Pegasus bank, determined from the charge voltage divided by the characteristic impedance of the capacitor bank is -- 10 MA. When used to perform direct-drive, foil implosion experiments, the foil collapses to the axis when the current has risen to only -- 3 MA. The kinetic energy of the imploding foil for the direct-drive configuration cannot exceed -- 25% of the bank energy (lossless calculation). The plasma flow switch has been designed to have a conduction time of -- 4 μsec and a commutation time of -- 0.2 μsec. This permits flow implosion experiments to be performed at peak current. The soft x-ray output, as determined by volometry and by an array of filtered x-ray diodes, is compared for the two modes of operation

  3. Foil dissociation of fast molecular ions into atomic excited states

    International Nuclear Information System (INIS)

    The intensity and polarizations of light emitted from atomic excited states of dissociated molecular ions were measured. The dissociations are induced when fast molecular ions (50 to 500 keV/amu) are transmitted through thin carbon foils. A calculation of multiple scattering and the Coulomb explosion gives the average internuclear separation of the projectile at the foil surface. Experimentally, the foil thickness is varied to give varying internuclear separations at the foil surface and observe the consequent variation in light yield and optical polarization. Using HeH+ projectiles, factors of 1 to 5 enhancements of the light yields from n = 3, 13P,D states of He I and some He II and H I emissions were observed. The results can be explained in terms of molecular level crossings which provide mixings of the various final states during dissociation of the molecular ions at the exit surface. They suggest a short range surface interaction of the electron pick-up followed by a slow molecular dissociation. Alignment measurements confirm the essential features of the model. Observations of Lyman α emission after dissociation of H2+ amd H3+ show rapid variations in light yield for small internuclear separations at the foil surface

  4. Design and optimization of vertex detector foils by superplastic forming

    CERN Document Server

    Snippe, Quirin Hendrik Catherin; Meinders, V T

    2011-01-01

    The production of one of the parts in a particle detector, called the RF Foil, has been a very intensive process in the past. The design and production process, which had a trial and error character, led eventually to an RF Foil that met the most important requirement: a sufficient leak tightness value. Since these kinds of foils have to be produced in the future, it is desirable to shorten the development stage with a view to cost reduction. This research project investigates how this part can be optimized with respect to the radiation length. An important limiting factor within this optimization process is the leak tightness of the foil. The intended production method this research will investigate is superplastic forming (SPF). On the one hand, the goal is to use finite element calculations to predict the forming behavior. The leak tightness of the formed foil must also be predicted within these calculations. On the other hand, an optimization strategy is necessary to reduce the radiation length of the RF ...

  5. Development of Tracking Detectors with industrially produced GEM Foils

    CERN Document Server

    Simon, F; Becker, U; Burns, L; Crary, D; Kearney, K; Keeler, G; Majka, R; Paton, K; Saini, G; Smirnov, N; Surrow, B; Woody, C

    2007-01-01

    The planned tracking upgrade of the STAR experiment at RHIC includes a large-area GEM tracker used to determine the charge sign of electrons and positrons produced from W+(-) decays. For such a large-scale project commercial availability of GEM foils is necessary. We report first results obtained with a triple GEM detector using GEM foils produced by Tech-Etch Inc. of Plymouth, MA, USA. Measurements of gain uniformity, long-term stability as well as measurements of the energy resolution for X-Rays are compared to results obtained with an identical detector using GEM foils produced at CERN. A quality assurance procedure based on optical tests using an automated high-resolution scanner has been established, allowing a study of the correlation of the observed behavior of the detector and the geometrical properties of the GEM foils. Detectors based on Tech-Etch and CERN produced foils both show good uniformity of the gain over the active area and stable gain after an initial charge-up period, making them well sui...

  6. Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.

  7. Dosimetric response of united, commercially available CTA foils for 60Co gamma rays

    International Nuclear Information System (INIS)

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for 60Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for 60Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life. (author)

  8. Flapping Instability of Two Tandem Flexible Foils in Uniform Axial Flow

    Science.gov (United States)

    Gurugubelli, Pardha Saradhi; Jaiman, Rajeev Kumar; Chua, Cassey

    2015-11-01

    We present a numerical analysis on the stability and coupled dynamics of two tandem flexible foils clamped at their leading edges in a uniform axial flow. The flexible foils considered for this study correspond to the fixed-point stable regime of the single flexible foil where the flexible foil aligns itself in the flow direction with no significant trailing edge oscillations. A high-order nonlinear coupled solver based on the variational formulation has been considered for analyzing the effects of gap between the foils on the stability and coupled behaviour of both the upstream and downstream foils. As a function of decreasing gap, it is observed that the tandem foil configuration is more prone to flapping instability than its single flexible foil counterpart. The evolution of the instability for the downstream foil shows two distinct dynamical scenarios: (i) only the downstream foil exhibits flapping motion and (ii) both the upstream and the downstream foils perform flapping. With the aid of a rigid foil in the upstream of a flexible foil, we further present a detailed analysis on the effects of the upstream wake and vortex shedding on the stability and flapping dynamics of the downstream foil.

  9. Relationship of Occlusal Schemes with the Occurrence of Temporomandibular Disorders

    Directory of Open Access Journals (Sweden)

    Dina H. Sugiaman

    2013-07-01

    Full Text Available Masticatory system is a complex functional unit of the body responsible for mastication, speech, and deglutition process. Temporomandibular disorders (TMD is used to describe all functional disturbances of the masticatory system. The etiology of TMD is multifactorial, such as occlusal disharmony and emotional stress. The relationship between occlusion and TMD has been highly debated in dentistry, one of the occlusal factors is the occlusal scheme. Occlusal schemes are defined as bilateral canine guidance, unilateral canine guidance, group function and balanced occlusion. However, studies about the relationship of occlusal schemes and the occurrence of the TMD are still limited and remained controversial. Objective: To investigate the relationship of occlusal schemes witht he occurrence of TMD. Methods: A cross-sectional study was conducted at the Faculty of Dentistry, Uniiversitas Indonesia. A total of 127 students were included in this study. Subjects were examined based on Clinical Helkimo Index and divided into TMD and non-TMD groups. Subjects were categorized as non-TMD groups if the value of the clinical Helkimo index was 0 and as TMD group when the value ranged between 1-25. Results: Balanced occlusion schemes has a greater risk of TMD occurrence with odds ratio value 5.6 and 95% confidence interval 1.188 to 26.331 (p=0.021. Conclusion: Balanced occlusion has a significant relationship with the occurrence of TMD.

  10. Highly sensitive urea sensing with ion-irradiated polymer foils

    International Nuclear Information System (INIS)

    Recently we prepared urea-sensors by attaching urease to the inner walls of etched ion tracks within thin polymer foil. Here, alternative track-based sensor configurations are examined where the enzyme remained in solution. The conductivities of systems consisting of two parallel irradiated polymer foils and confining different urea/urease mixtures in between were examined. The correlations between conductivity and urea concentration differed strongly for foils with unetched and etched tracks, which points at different sensing mechanisms – tentatively attributed to the adsorption of enzymatic reaction products on the latent track entrances and to the enhanced conductivity of reaction product-filled etched tracks, respectively. All examined systems enable in principle, urea sensing. They point at the possibility of sensor cascade construction for more sensitive or selective sensor systems.

  11. Development of single mask GEM foils in India

    International Nuclear Information System (INIS)

    There are various techniques available around the globe for making punch through holes for Micro Pattern Gas Detectors (MPGDs), such as Gas Electron Multipliers (GEMs). The GEM foils consists of 5 μm of Cu clad on both the sides of 50 μm polymide (PMMA/kapton) (5/50/5). At present these foils are developed in South Korea without having any adhesive between the Cu and polymide. The available techniques range from chemical etching, reactive plasma etching and laser etching. However, for GEM detectors, having an active area upto 5000 cm2, the chemical etching process using a Single Mask has been developed at CERN which is faster from the viewpoint of mass production of such foils for the upgrades which are foreseen in a couple of years with the Large Hadron Collider facility at CERN

  12. Analysis of texture of niobium thin wire and foil

    International Nuclear Information System (INIS)

    Distribution of texture components in 0.5 mm cold-worked wire and 40 μm foil (ε = 90 and 95% respectively) is investigated by X-ray diffraction method. Inhomogeneity of the product deformation texture is revealed. Textures of internal wire and foil metal volumes are traditionals ones as in similar products of bcc metals while for surface layers of metal with 5-10 μm thickness specific material textures are found. Shear texture (110) (001) of foil metal surface layer at annealing is enforced at the expense of prevailing growth in a matrix with rolling plane deformation. Removal of the metal layer with shear texture prior before annaling using etching leads to recrystallization in situ with the preservation of plane rolling deformation texture (001)-(112) (100)+(554) (225)

  13. Occlusion and weight change in a patient after esophagectomy: success derived from restoration of occlusal support.

    Science.gov (United States)

    Yamanaka, Reiko; Soga, Yoshihiko; Minakuchi, Mami; Nawachi, Kumiko; Maruyama, Takayuki; Kuboki, Takuo; Morita, Manabu

    2013-01-01

    Occlusal support may be an important factor affecting nutritional support after major surgery. This report presents a patient who gained body weight after receiving a new prosthesis. The patient was an 82-year-old man with thoracic esophageal carcinoma. He did not have occlusal support because of multiple caries lesions. His body weight slowly increased after surgery, but almost stopped in the period of 54 to 68 days after surgery. After treatment with dentures (day 72 postsurgery), body weight gain was observed again, although his medical treatment had not changed. An appropriate prosthesis could contribute to perioperative nutrition support and may lead to earlier recovery after surgery. PMID:24179973

  14. Fabrication of antiferroelectric PLZT films on metal foils

    International Nuclear Information System (INIS)

    Fabrication of high-dielectric-strength antiferroelectric (AFE) films on metallic foils is technically important for advanced power electronics. To that end, we have deposited crack-free Pb0.92La0.08Zr0.95Ti0.05O3 (PLZT 8/95/5) films on nickel foils by chemical solution deposition. To eliminate the parasitic effect caused by the formation of a low-permittivity interfacial oxide, a conductive buffer layer of lanthanum nickel oxide (LNO) was coated by chemical solution deposition on the nickel foil before the deposition of PLZT. Use of the LNO buffer allowed high-quality film-on-foil capacitors to be processed in air. With the PLZT 8/95/5 deposited on LNO-buffered Ni foils, we observed field- and thermal-induced phase transformations of AFE to ferroelectric (FE). The AFE-to-FE phase transition field, EAF = 225 kV/cm, and the reverse phase transition field, EFA = 190 kV/cm, were measured at room temperature on a ∼1.15 μm-thick PLZT 8/95/5 film grown on LNO-buffered Ni foils. The relative permittivities of the AFE and FE states were ∼600 and ∼730, respectively, with dielectric loss ∼0.04 at room temperature. The Curie temperature was ∼210 deg. C. The thermal-induced transition of AFE-to-FE phase occurred at ∼175 deg. C. Breakdown field strength of 1.2 MV/cm was measured at room temperature

  15. Method and apparatus for tensile testing of metal foil

    Science.gov (United States)

    Wade, O. W. (Inventor)

    1976-01-01

    A method for obtaining accurate and reproducible results in the tensile testing of metal foils in tensile testing machines is described. Before the test specimen are placed in the machine, foil side edges are worked until they are parallel and flaw free. The specimen are also aligned between and secured to grip end members. An aligning apparatus employed in the method is comprised of an alignment box with a longitudinal bottom wall and two upright side walls, first and second removable grip end members at each end of the box, and a means for securing the grip end members within the box.

  16. Electrochemically replicated smooth aluminum foils for anodic alumina nanochannel arrays.

    Science.gov (United States)

    Biring, Sajal; Tsai, Kun-Tong; Sur, Ujjal Kumar; Wang, Yuh-Lin

    2008-01-01

    A fast electrochemical replication technique has been developed to fabricate large-scale ultra-smooth aluminum foils by exploiting readily available large-scale smooth silicon wafers as the masters. Since the adhesion of aluminum on silicon depends on the time of surface pretreatment in water, it is possible to either detach the replicated aluminum from the silicon master without damaging the replicated aluminum and master or integrate the aluminum film to the silicon substrate. Replicated ultra-smooth aluminum foils are used for the growth of both self-organized and lithographically guided long-range ordered arrays of anodic alumina nanochannels without any polishing pretreatment. PMID:21730530

  17. Modeling the registration efficiency of thermal neutrons by gadolinium foils

    CERN Document Server

    Abdushukurov, D A; Bondarenko, D V; Chistyakov, D Y; Muminov, K K; Toshov, T A; Muminov, Kh.Kh.

    2007-01-01

    In the paper we present the results of mathematical modeling of the registration efficiency of thermal neutrons for the converters made of natural Gd and its 157 isotope plane-parallel foils. In the performed calculations four fixed energies of neutrons with the corresponding wavelengths of 1, 1.8, 3 and 4 $A^0$ are taken into account. We calculate the efficiencies of the converter for electron escapes to frontward and backward hemispheres and their sum, depending on thickness of converting foils. Results of comparison of our calculations with the experimental data are presented.

  18. DOC: Deep OCclusion Estimation From A Single Image

    OpenAIRE

    Wang, Peng; Yuille, Alan

    2015-01-01

    Recovering the occlusion relationships between objects is a fundamental human visual ability which yields important information about the 3D world. In this paper we propose a deep network architecture, called DOC, which acts on a single image, detects object boundaries and estimates the border ownership (i.e. which side of the boundary is foreground and which is background). We represent occlusion relations by a binary edge map, to indicate the object boundary, and an occlusion orientation va...

  19. Occlusion of the anterior cerebral artery after head trauma

    OpenAIRE

    2013-01-01

    Intracranial arterial occlusion is rarely encountered in association with head injury. Only six cases of traumatic occlusion of the anterior cerebral artery (ACA) have previously been reported. In this paper, the authors describe a case of a posttraumatic occlusion of ACA. A 35-year-old male presented to the emergency room with severe head injury. Computed tomography (CT) scan displayed diffuse brain swelling with multiple skull fractures. Follow up CT scan showed extensive cerebral infarctio...

  20. Occlusal adjustment in the treatment of primary traumatic injury

    Directory of Open Access Journals (Sweden)

    Raulino Naves Borges

    2011-01-01

    Full Text Available A major concern in dentistry is the correct distribution of occlusal forces to promote balance among the elements of the stomatognathic system. Occlusal trauma may develop in situations where the magnitude of the load exerted by occlusion exceeds the ability of the periodontium surrounding the involved teeth to resist and distribute the resulting forces without moving. A 41-year-old female patient was referred to the Occlusion and Orofacial Pain Research Center at the School of Dentistry, Universidade Federal de Goiás, Brazil, with headache, temporomandibular joint pain, toothache, and bone resorption on the distal aspect of tooth #33. During clinical examination, a 2-mm difference between centric relation and habitual occlusion was detected, with interference between teeth #28 and #38, causing anterior projection of the mandible to the right. Probing depth of the lower canine was within normal limits, with a positive pulp vitality test. We concluded that pain and (grade II mobility in tooth #33 were caused by interference of third molars, which exerted a distal pressure on the lower canine, characterizing primary occlusal trauma. Occlusal adjustment by selective grinding was then indicated to eliminate premature contact. Ten sessions were required to obtain optimal occlusion. Three months after treatment, follow-up radiograph showed newly formed bone tissue between teeth #33 and #34, with absence of mobility and symptoms. The case reported here indicates that occlusal adjustment is recommended for the treatment of periodontal injuries caused by traumatic occlusion. The treatment allows the achievement of an optimal occlusion by directing occlusal forces to the long axis of the teeth.

  1. Occlusal adjustment in the treatment of secondary traumatic injury

    Directory of Open Access Journals (Sweden)

    Raulino Naves Borges

    2011-01-01

    Full Text Available The success of the rehabilitation treatment is associated with the relationship between occlusion and periodontal status. When occlusal loads exceed the ability of the periodontium to resist and distribute the resulting forces, injuries may develop, leading to failures in dental practice. A 35-year-old female patient presented at the Occlusion and Orofacial Pain Research Center at the School of Dentistry, Universidade Federal de Goiás, Brazil, complaining of pain and mobility in the maxillary central incisors and sensitivity in the mandibular left incisors and canine. Symptoms began after cast metal restoration was performed in tooth #27. Clinical examination revealed a signifi cant difference of 1 mm between centric relation and habitual occlusion, presence of a periodontal pocket 5 mm deep in the mesial aspect of tooth #11, and an increased vertical dimension of occlusion caused by occlusal interference between teeth #27 and #37. Radiographic examination detected vertical bone loss between teeth #21 and #11, on the mesial aspect of tooth #33 and between the lower incisors. The lower teeth also showed radiographic evidence of periapical lesions. Occlusal interference caused anterior projection of the mandible to the right, overloading the incisors. Treatment by occlusal adjustment was performed to promote an equal incidence of forces on all aspects of the teeth. Twelve sessions were required to achieve a balanced occlusion and restore the physiological vertical dimension of occlusion. Six months after treatment, there was radiographic evidence of newly formed bone tissue between teeth #11 and #21, regression of apical periodontitis in the lower teeth, and a decrease in mobility and all associated symptoms. Secondary traumatic injury may be responsible for changes in apical tooth structures. Occlusal adjustment may favor the direction of occlusal forces to the long axis of the teeth.

  2. Local Intra-Arterial Fibrinolysis in Acute Basilar Artery Occlusion

    OpenAIRE

    Enomoto, Y.; Yoshimura, S.; Kitajima, H.; Tamakawa, N.; Iwama, T

    2007-01-01

    Acute basilar artery (BA) occlusion is typically associated with poor outcome; however newer diagnostic and treatment modalities have the potential to improve prognosis. In this study, six patients with acute BA occlusion were followed and the effectiveness of local intra-arterial fibrinolysis (LIF) and subsequent percutaneous transluminal angioplasty (PTA) with a balloon catheter were assessed. Of the six patients with BA occlusion observed in this study, two had extended brain stem infarcti...

  3. Early rethrombosis in femoropopliteal occlusions treated with percutaneous transluminal angioplasty

    DEFF Research Database (Denmark)

    Jørgensen, B; Meisner, S; Holstein, P;

    1990-01-01

    was explained by a high incidence (41%) of rethrombosis within hours of dilatation. Early rethrombosis was seen with all lengths of occlusion (1-27 cm) with no statistically significant difference from other subsets. This study concludes that conventional PTA in femoropopliteal occlusions should be...... reserved for cases of limb salvage, preferably in patients who are technically inoperable. We suggest a new technique of segmentally enclosed thrombolysis to prevent early rethrombosis after PTA in femoropopliteal occlusions....

  4. Preparation of the charge stripping foil in J-PARC RCS

    International Nuclear Information System (INIS)

    At the J-PARC 3-GeV Rapid Cycling Synchrotron (RCS), the H-charge exchange injection scheme using striping foils is adopted. The 1st stripping foil is mounted on a C-shaped holder. One edge of the foil is supported by the holders and the other edge is sandwiched by 10 μm diameter SiC fibers. The holders with not only operation foil but also spare foils were stored on the holder storage rack. The 1st stripping foil is one of the key elements deciding the beam performance in the RCS. Thus the foil preparation is very important issue. The foil preparation includes many work process as follows: a foil separation from glass substrates, salvaging the foil from the water, foil annealing, SiC fibers glueing and foil mount on the holder, and foil holders storing in the holder storage rack. In order to improve its reproducibility and increase the efficiency of work, attachment devices or support jigs are developed. (author)

  5. Accurate Detection of Non-Iris Occlusions

    Czech Academy of Sciences Publication Activity Database

    Haindl, Michal; Krupička, Mikuláš

    Los Alamitos, USA: IEEE Computer Society CPS, 2014 - (Yetongno, K.; Dipanda, A.; Chbeir, R.), s. 49-56 ISBN 978-1-4799-7978-3. [Tenth International Conference on Signal-Image Technology & Internet-Based Systems (SITIS 2014). Marrakech (MA), 23.11.2014-27.11.2014] R&D Projects: GA ČR(CZ) GA14-10911S Institutional support: RVO:67985556 Keywords : iris occlusions * detection * textural model Subject RIV: BD - Theory of Information http://library.utia.cas.cz/separaty/2014/RO/haindl-0436547.pdf

  6. Hydrocolloid occlusion for the treatment of neurovascular corns

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Beck, Jan Walther; Reumert, L N;

    1991-01-01

    The goal of this study was to determine the effect of hydrocolloid occlusion on neurovascular corns. The design was an observer-blinded, randomized, controlled study. Thirty consecutive patients participated in the trial. The patients received curettage alone or curettage with hydrocolloid...... occlusion. Six treatments were given over 12 weeks. A follow-up examination was performed 3 months after termination of the trial. Outcome measures were the size of the corns, a discomfort score, and an overall judgment of the trial. The results demonstrated no benefit of occlusion for symptoms or signs of...... neurovascular corns. The patients treated with occlusion were, however, generally more satisfied than the conventional group....

  7. Analysis of thermal effect for China spallation neutron source primary stripper foil

    International Nuclear Information System (INIS)

    Primary stripper foil device is one of the most important devices in rapid cycling synchrotron of China Spallation Neutron Source (CSNS). In normal operation conditions, the high temperature and other thermal effects on foil are the main factors which influence the foil's lifetime. In order to predict the foil's working conditions and choose an appropriate design scheme, the finite element analysis software was utilized to calculate the foil's temperature, thermal stress and deformation in different working conditions of CSNS-Ⅰ. The simulation result shows that the highest temperature on foil is 1450 K, and the mounting mode would hardly affect the thermal stress and deformation. Based on the simulation result, the final spare foil's number is designed to be 20, and the two-edge fixed method is utilized as the foil's mounting scheme. (authors)

  8. Material Properties of Laser-Welded Thin Silicon Foils

    Directory of Open Access Journals (Sweden)

    M. T. Hessmann

    2013-01-01

    Full Text Available An extended monocrystalline silicon base foil offers a great opportunity to combine low-cost production with high efficiency silicon solar cells on a large scale. By overcoming the area restriction of ingot-based monocrystalline silicon wafer production, costs could be decreased to thin film solar cell range. The extended monocrystalline silicon base foil consists of several individual thin silicon wafers which are welded together. A comparison of three different approaches to weld 50 μm thin silicon foils is investigated here: (1 laser spot welding with low constant feed speed, (2 laser line welding, and (3 keyhole welding. Cross-sections are prepared and analyzed by electron backscatter diffraction (EBSD to reveal changes in the crystal structure at the welding side after laser irradiation. The treatment leads to the appearance of new grains and boundaries. The induced internal stress, using the three different laser welding processes, was investigated by micro-Raman analysis. We conclude that the keyhole welding process is the most favorable to produce thin silicon foils.

  9. An 8b organic microprocessor on plastic foil

    NARCIS (Netherlands)

    Myny, K.; Veenendaal, E. van; Gelinck, G.H.; Genoe, J.; Dehaene, W.; Heremans, P.

    2011-01-01

    We introduce a microprocessor made by organic thin-film transistors processed directly onto flexible plastic foil. This is a direct realization of a microprocessor by thin-film technology, i.e., without transfer, on plastic. It paves the way to equip mundane supports and objects with low-cost comput

  10. Foil Bearing Starting Considerations and Requirements for Rotorcraft Engine Applications

    Science.gov (United States)

    Radil, Kevin C.; DellaCorte, Christopher

    2009-01-01

    Foil gas bearings under development for rotorcraft-sized, hot core engine applications have been susceptible to damage from the slow acceleration and rates typically encountered during the pre-ignition stage in conventional engines. Recent laboratory failures have been assumed to be directly linked to operating foil bearings below their lift-off speed while following conventional startup procedures for the engines. In each instance, the continuous sliding contact between the foils and shaft was believed to thermally overload the bearing and cause the engines to fail. These failures highlight the need to characterize required acceleration rates and minimum operating speeds for these applications. In this report, startup experiments were conducted with a large, rotorcraft engine sized foil bearing under moderate load and acceleration rates to identify the proper start procedures needed to avoid bearing failure. The results showed that a bearing under a 39.4 kPa static load can withstand a modest acceleration rate of 500 rpm/s and excessive loitering below the bearing lift-off speed provided an adequate solid lubricant is present.

  11. Characteristic Differences Between Wire and Foil X-pinches

    Science.gov (United States)

    Collins, Gilbert; Valenzuela, Julio; Krasheninnikov, Igor; Beg, Farhat; Wei, Mingsheng

    2015-11-01

    We conducted X-pinch experiments using laser-cut Ni and Cu foils on the 250kA GenASIS current driver at UC San Diego. General Atomics' Laser Micro-Machining (LMM) Center manufactured the X's. To characterize the foil X-pinches, we measured and compared the evolution, emission spectra, yield, and source size of these new arrays to that of comparably massed wire X-pinches on the same driver. Diagnostics included Si PN diodes and diamond PCDs, optical probing, X-ray spectroscopy, an XUV framing camera, a slit-wire camera, and current probes. We used novel structures machined into the crosspoint in an effort to better understand the effects of the initial geometry on the final pinch and to spatially confine the source location. Some designs entirely prohibited pinching. In other designs, when pinching occurred, the sources were comparable to ideal wire shots on GenASIS both in size (at or less than five microns) and X-ray flux (5-10 MW @ 1-10 keV). The data collected here also show considerable differences between successful foil and wire pinches. The X-ray spectra are not identical, and we find that the foil X's produce a single >2.5 keV emission pulse with none of the additional later and longer-lasting hard emission pulses found in wire X-pinches.

  12. Absolute neutronic performance of SNS from gold foil application

    International Nuclear Information System (INIS)

    The determination of absolute neutron fluxes by white beam activation of thick gold foils in conjuction with spectral analysis by time-of-flight monitors is described. A numerical integration procedure is presented and the method applied to determining the absolute performance of SNS from data obtained during the initial commissioning run in December 1984. (author)

  13. The use of fission foils for plasma neutron diagnostics

    International Nuclear Information System (INIS)

    Commonly used fission foil materials have been examined for their application to plasma diagnostics as activation foils. Such foils have been used extensively in the past for fission reactor dosiemetry. They have very well known fission cross sections, and in most cases the fission yields are reasonably well known. The materials included in this study are 226Ra, 228Th, 232Th, 231Pa, 233U, 235U, 238U, 237Np, 238Pu, and 239Pu. Of these materials 232Th, 235U, and 238U are considered to be very good candidates for this application. The others have been eliminated because of high background radioactivity, impurities which present high backgrounds, or lack of knowledge about yield distribution of fission products. Production cross sections for fission products in the vicinity of the yield maxima (A = 85 - 101, 133 143) have been calculated from known fission cross sections and independent or cumulative yields at thermal energies (where applicable) and 14 MeV. Recent measurements at 2.5 MeV are also included. For one foil (232Th) results for 3 MeV and 11 MeV are also available. The decay schemes of the more prominent fission products have been thoroughly studied and good measurement precision should result from their use

  14. Transmission of fast H3+ molecules through thin carbon foils

    International Nuclear Information System (INIS)

    Observed for the first time is the transmission of H3+ molecules (2.4 MeV) through carbon foils (2 - 7μg/cm2). The thickness dependence of the yield follows a single decreasing exponential function with a unity coefficient which is expected for H3+ transmitted with their original electrons

  15. The Visualization of Infrared Radiation Using Thermal Sensitive Foils

    Science.gov (United States)

    Bochnícek, Zdenek

    2013-01-01

    This paper describes a set of demonstration school experiments where infrared radiation is detected using thermal sensitive foils. The possibility of using standard glass lenses for infrared imaging is discussed in detail. It is shown that with optic components made from glass, infrared radiation up to 2.5 µm of wavelength can be detected. The…

  16. Grafting of polyethylene foils by vinyltrimethoxysilane using radiofrequency plasma discharge

    Czech Academy of Sciences Publication Activity Database

    Krupa, I.; Nedelčev, T.; Novák, I.; Kleinová, A.; Špírková, Milena

    Bratislava: Polymer Institute of the Slovak Academy of Sciences, 2006. s. 173-174. ISBN 80-968433-3-8. [Bratislava International Conference on Macromolecules: Advanced Polymeric Materials /20./. 11.06.2006-15.06.2006, Bratislava] Institutional research plan: CEZ:AV0Z40500505 Keywords : grafting * polyethylene foils Subject RIV: CD - Macromolecular Chemistry

  17. Effect of sheet thickness on deep drawing of metal foils

    Directory of Open Access Journals (Sweden)

    Y. Marumo

    2007-01-01

    Full Text Available Purpose: The objective of the present work is to study the influence of sheet thickness on blank holding forceand limiting drawing ratio.Design/methodology/approach: Variation in blankholding force and limiting drawing ratio in deep drawing ofmetal foils were evaluated by calculation.Findings: The paper shows variation in the blankholding force required for the elimination of wrinkling and thelimiting drawing ratio with sheet thickness. The blankholding force required for the elimination of wrinklingincreased rapidly as the sheet thickness decreased. When the sheet thickness was very thin, the blankholdingforce was strongly influenced by the coefficient of friction. The limiting drawing ratio decreased as sheetthickness decreased and it decreased rapidly below 0.04 mm thickness. When the sheet thickness was very thin,the limiting drawing ratio was strongly influenced by the coefficient of friction.Research limitations/implications: The control of the loading path of blankholding force will be an effectiveway to prevent the formation of defects including fractures and wrinkles in deep drawing of metal foils.Practical implications: When deep drawing of metal foils is carried out, the control of loading path of blankholdingforce during deep drawing operation can be very effective for improving the limiting drawing ratio.Originality/value: The contribution of the conducted research is observed in a possible view of improvementof deep drawability of metal foils.

  18. Numerical analysis of human dental occlusal contact

    Science.gov (United States)

    Bastos, F. S.; Las Casas, E. B.; Godoy, G. C. D.; Meireles, A. B.

    2010-06-01

    The purpose of this study was to obtain real contact areas, forces, and pressures acting on human dental enamel as a function of the nominal pressure during dental occlusal contact. The described development consisted of three steps: characterization of the surface roughness by 3D contact profilometry test, finite element analysis of micro responses for each pair of main asperities in contact, and homogenization of macro responses using an assumed probability density function. The inelastic deformation of enamel was considered, adjusting the stress-strain relationship of sound enamel to that obtained from instrumented indentation tests conducted with spherical tip. A mechanical part of the static friction coefficient was estimated as the ratio between tangential and normal components of the overall resistive force, resulting in μd = 0.057. Less than 1% of contact pairs reached the yield stress of enamel, indicating that the occlusal contact is essentially elastic. The micro-models indicated an average hardness of 6.25GPa, and the homogenized result for macroscopic interface was around 9GPa. Further refinements of the methodology and verification using experimental data can provide a better understanding of processes related to contact, friction and wear of human tooth enamel.

  19. Numerical analysis of human dental occlusal contact

    International Nuclear Information System (INIS)

    The purpose of this study was to obtain real contact areas, forces, and pressures acting on human dental enamel as a function of the nominal pressure during dental occlusal contact. The described development consisted of three steps: characterization of the surface roughness by 3D contact profilometry test, finite element analysis of micro responses for each pair of main asperities in contact, and homogenization of macro responses using an assumed probability density function. The inelastic deformation of enamel was considered, adjusting the stress-strain relationship of sound enamel to that obtained from instrumented indentation tests conducted with spherical tip. A mechanical part of the static friction coefficient was estimated as the ratio between tangential and normal components of the overall resistive force, resulting in μd = 0.057. Less than 1% of contact pairs reached the yield stress of enamel, indicating that the occlusal contact is essentially elastic. The micro-models indicated an average hardness of 6.25GPa, and the homogenized result for macroscopic interface was around 9GPa. Further refinements of the methodology and verification using experimental data can provide a better understanding of processes related to contact, friction and wear of human tooth enamel.

  20. Metabolic syndrome and central retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Kosanović-Jaković Natalija

    2005-01-01

    Full Text Available Background. The accumulation of risk factors for central retinal artery occlusion can be seen in a single person and might be explained by the metabolic syndrome. Case report. We presented the case of a 52-year-old man with no light perception in his right eye. The visual loss was monocular and painless, fundoscopy showed central retinal artery occlusion and the laboratory investigation showed the raised erythrocyte sedimentation rate of 105 mm/h and the raised C-reactive protein of 22 mg/l. Specific laboratory investigations and fluorescein angiography excluded the presence of vasculitis, collagen vascular diseases, hypercoagulable state and antiphospholipid syndrome. Conclusion. The patient met all the five of the National Cholesterol Education Program (NCEP criteria for the metabolic syndrome: hypertension, abnormal lipid profile, abnormal glucose metabolism, obesity and hyperuricemia. Measurement of C-reactive protein is useful for the assessment of therapeutic systemic effect on any abnormality in the metabolic syndrome. Individual therapy for all risk factors in the metabolic syndrome is necessary to prevent complications such as cardiovascular, retinal vascular diseases and stroke.

  1. Anthropology, tooth wear, and occlusion ab origine.

    Science.gov (United States)

    Young, W G

    1998-11-01

    The purpose of this essay is to emphasize that anthropology, the study of man in his environments, is a potent tool for scientific discovery and inspiration in dental science. It attempts to capture flashes of creative anthropological insight which have illuminated studies of tooth wear and occlusion in the past. While it documents contributions, understandings, and misunderstandings from Australian and New Zealand dentists, it is not a hagiography. The real saint of this essay is the Australian aborigine. For when men and women are understood in their environments, much is learned from them which challenges preconceptions of our dental science culture. The essay concludes that new, contemporary Australian culture needs to be studied by anthropological approaches if we are to understand how dental erosion is exacerbating tooth wear and damaging the occlusions of contemporary Australians. Much remains to be discovered about contemporary lifestyles, habits, and diets that lead to dental erosion, the principal cause of contemporary tooth wear in this part of the world. PMID:9823723

  2. Experimental and theoretical analysis of a rigid rotor supported by air foil bearings

    DEFF Research Database (Denmark)

    Larsen, Jon Steffen; Hansen, Asger J. T.; Santos, Ilmar

    2015-01-01

    The popularity of compressors utilizing foil bearings is increasing. Their mechanical design is challenging, and an accurate prediction of the bearing coefficients is important. A mathematical model taking into account the foil structure, and the detailed geometry of a three pad foil bearing are...

  3. Bilateral vertebral artery balloon occlusion for giant vertebrobasilar aneurysms

    International Nuclear Information System (INIS)

    We describe the clinical presentation, radiological and clinical results in six consecutive patients with a giant vertebrobasilar aneurysm treated by bilateral vertebral artery balloon occlusion. Five patients presented with headache and signs of brain-stem compression and one with subarachnoid haemorrhage. In all patients vertebral artery balloon occlusion was performed. In four, this followed successful test occlusion. In one patient, who did not tolerate the test occlusion, a bypass from the external carotid to the posterior cerebral artery preceded definitive vertebral artery occlusion. One patient underwent bypass surgery prior to test occlusion. At 6-22 months follow-up three patients had a good functional outcome and showed unchanged size or shrinkage of the aneurysm on MRI. Three other patients died; one from recurrent haemorrhage, and two probably from delayed brain-stem ischaemia. The presence of two large posterior communicating arteries predicted good functional outcome, which was also related to the clinical condition at presentation, and the degree of brain-stem compression and oedema on MRI. Bilateral vertebral artery balloon occlusion can be considered in patients with otherwise untreatable giant vertebrobasilar aneurysms. If test occlusion is not tolerated, a surgical bypass to the posterior circulation can be considered. (orig.)

  4. The Effect of Occlusion on Motion Integration in Infants

    Science.gov (United States)

    Otsuka, Yumiko; Konishi, Yukuo; Kanazawa, So; Yamaguchi, Masami K.

    2009-01-01

    Previous psychophysical studies have shown that the adult human visual system makes use of form information such as occlusion to determine whether to integrate or segregate local motion signals (J. McDermott, Y. Weiss, & E. H. Adelson, 2001). Using the displays developed by McDermott et al., these experiments examined whether occlusion and amodal…

  5. Guide wire extension for shape memory polymer occlusion removal devices

    Science.gov (United States)

    Maitland, Duncan J.; Small, IV, Ward; Hartman, Jonathan

    2009-11-03

    A flexible extension for a shape memory polymer occlusion removal device. A shape memory polymer instrument is transported through a vessel via a catheter. A flexible elongated unit is operatively connected to the distal end of the shape memory polymer instrument to enhance maneuverability through tortuous paths en route to the occlusion.

  6. Comorbidity in patients with branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Bertelsen, Mette; Linneberg, Allan René; Rosenberg, Niels Thomas; Christoffersen, Nynne; Vorum, Henrik; Gade, Else; Larsen, Michael

    2012-01-01

    To evaluate comorbidity before and after the diagnosis of branch retinal vein occlusion to determine whether it is a consequence of arterial thickening and therefore could serve as a diagnostic marker for other comorbidities and to evaluate the risk factors for the development of such occlusion....

  7. Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk; Kim, Jin Soo; You, Choong Hyun [Chosun University College of Medicine, Kwangju (Korea, Republic of)

    2005-03-15

    To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occulsion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  8. Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography

    International Nuclear Information System (INIS)

    To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occulsion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  9. Dorzolamide increases retinal oxygen tension after branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Noergaard, Michael Hove; Bach-Holm, Daniella; Scherfig, Erik;

    2008-01-01

    To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs.......To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs....

  10. Cognitive impairments in patients with cerebrovascular steno-occlusive disease

    Institute of Scientific and Technical Information of China (English)

    石丹

    2012-01-01

    Objective To explore the relationship between cerebrovascular steno-occlusive disease and neuropsychological performance by cognitive function assessment. Methods Using a case-control study,45 patients with cerebrovascular steno-occlusive lesions (patient group) and 59 control subjects without cerebrovascular

  11. An adaptive occlusion culling algorithm for use in large ves

    DEFF Research Database (Denmark)

    Bormann, Karsten

    2000-01-01

    The Hierarchical Occlusion Map algorithm is combined with Frustum Slicing to give a simpler occlusion-culling algorithm that more adequately caters to large, open VEs. The algorithm adapts to the level of visual congestion and is well suited for use with large, complex models with long mean free...

  12. Clinical application of hepatic venous occlusion for hepatectomy

    Institute of Scientific and Technical Information of China (English)

    PAN Ze-ya; YANG Yuan; ZHOU Wei-ping; LI Ai-jun; FU Si-yuan; WU Meng-chao

    2008-01-01

    Background Most liver resections require clamping of the hepatic pedicle (Pringle maneuver) to avoid excessive blood loss. But Pringle maneuver can not control backflow bleeding of hepatic vein, Resection of liver tumors involving hepatic veins may cause massive hemorrhage or air embolism from the injuries of the hepatic veins. Although total hepatic vascular exclusion can prevent bleeding of the hepatic veins effectively, it also may result in systemic hemodynamic disturbance because of the inferior vena cava being clamped. Hepatic venous occlusion, a new technique, can control the inflow and outflow of the liver without clamping the vena cava.Methods A total of 71 cases of liver tumors underwent resection with occlusion of more than one of the main hepatic veins. All tumors involved the second porta hepatis and at least one main hepatic vein. Ligation or occlusion with serrefines, tourniquets and auricular clamps were used in hepatic venous occlusion.Results Of the 71 patients, ligation of the hepatic veins was used in 28 cases, occlusion with a tourniquet in 26, and occlusion with a serrefine in 17. Right hepatic veins were occluded in 38 cases, both right and middle hepatic veins in 2,the common trunk of the left and middle hepatic veins in 24, branches of the left and middle hepatic veins in 2, and all three hepatic veins in 5. Thirty-five cases underwent hemihepatic vascular occlusion, 4 alternate hemihepatic vascular occlusion, 23 portal triad clamping plus selective hepatic vein occlusion, and 9 portal triad clamping plus total hepatic vein occlusion. The third porta hepatis was isolated in 26 cases. The amount of intraoperative blood loss averaged (540±283) (range 100 to 1000) ml in the group of total hemihepatic vascular occlusion and in the group of alternate hemihepatic vascular occlusion, (620±317) (range 200-6000) ml in the group of portal triad clamping plus selective or total hepatic vein occlusion. All tumors were completely removed

  13. Epidemiology of aortic disease - aneurysm, dissection, occlusion

    International Nuclear Information System (INIS)

    The physiological infrarenal aortic diameter varies between 12.4 mm in women an 27.6 mm in men. As defined, an aneurysmatic dilatation begins with 29 mm. According to that, 9% of all people above the age of 65 are affected by an abdominal aortic aneurysm (AAA). Compared with the female sex, the male sex predominates at a rate of about 5:1. The disease is predominant in men of the white race. In black men, black and white women the incidence of AAA is identical. 38 to 50 percent of the AAA patients (patients) suffer from hypertension, 33 to 60% from coronary, 28% from cerebrovascular and 25% from peripheral occlusive disease. The AAA expansion rate varies between 0.2 and 0.8 cm per year and is exponential from a diameter of 5 cm on. In autopsy studies, the rupture rates with AAA diameters of 7 cm were below 5%, 39% and 65%, respecitvely. 70% of the AAA patients do not die of a rupture, but of a cardiac disease. Serum markers, such as metalloproteinases and procollagen peptides are significantly increased in AAA patients. Thoraco-abdominal aneurysms (TAA) make up only 2 to 5% of all degenerative aneurysms. 20 to 30% of the TAA patients are also affected by an AAA. 80% of the TAA are degenerative, 15 to 20% are a consequence of the chronic dissection - including 5% of Marfan patients -, 2% occur in case of infections and 1 to 2% in case of aortitis. The TAA incidence in 100,000 person-years is 5.9% during a monitoring period of 30 years. In case of TAA, an operation is indicated with a maximum diameter of 5.5 to 6 cm and more and, in case of a Marfan's syndrome (incidence of 1:10,000), with a maximum diameter of 5.5 cm and more. With regard to aorto-iliac occlusive diseases, there are defined 3 types of distribution. Type I refers to the region of the bifurcation itself. Type II defines the diffuse aortoiliac spread of the disease. Type III designates multiple-level occlusions also beyond the inguinal ligament. Type I patients in most cases are female and more

  14. The Electroretinogram in Patients with Retinal Vascular Occlusion

    Institute of Scientific and Technical Information of China (English)

    Shizhou Huang; Lezheng Wu; Taiqing Luo; De-Zheng Wu; Futian Jiang; Guangwei Luo; Juanmei Ma

    2001-01-01

    Purpose: to measure and analyze the electroretinogram (ERG) in patients with retinal vascular occlusion. Method: fifty-eight cases (59 eyes) of retinal vascular occlusion and the fellow eyes of 47 cases were tested with Ganzfeld ERG. The scotopic and photopic ERG, and oscillatory potentials were tested according to the ERG standard of ISCEV. Results: The abnormal rates of Ops and b wave were higher in retinal vascular occlusion. The abnormal ERG appeared mostly in CRVO among four types of retinal vascular occlusion. The comparisons of some amplitudes and latencies between the fellow eyes and the affected eyes showed statistically significant difference. Conclusion: The oscillatory potentials and b waves have important roles in evaluating the retinal function of patients with retinal vascular occlusions. There are some clinical significance for comparing ERG between the affected eye and the fellow eye. Eye Science 2001; 17: 50 ~ 53.

  15. Dual scattering foil design for poly-energetic electron beams.

    Science.gov (United States)

    Kainz, K K; Antolak, J A; Almond, P R; Bloch, C D; Hogstrom, K R

    2005-03-01

    The laser wakefield acceleration (LWFA) mechanism can accelerate electrons to energies within the 6-20 MeV range desired for therapy application. However, the energy spectrum of LWFA-generated electrons is broad, on the order of tens of MeV. Using existing laser technology, the therapeutic beam might require a significant energy spread to achieve clinically acceptable dose rates. The purpose of this work was to test the assumption that a scattering foil system designed for a mono-energetic beam would be suitable for a poly-energetic beam with a significant energy spread. Dual scattering foil systems were designed for mono-energetic beams using an existing analytical formalism based on Gaussian multiple-Coulomb scattering theory. The design criterion was to create a flat beam that would be suitable for fields up to 25 x 25 cm2 at 100 cm from the primary scattering foil. Radial planar fluence profiles for poly-energetic beams with energy spreads ranging from 0.5 MeV to 6.5 MeV were calculated using two methods: (a) analytically by summing beam profiles for a range of mono-energetic beams through the scattering foil system, and (b) by Monte Carlo using the EGS/BEAM code. The analytic calculations facilitated fine adjustments to the foil design, and the Monte Carlo calculations enabled us to verify the results of the analytic calculation and to determine the phase-space characteristics of the broadened beam. Results showed that the flatness of the scattered beam is fairly insensitive to the width of the input energy spectrum. Also, results showed that dose calculated by the analytical and Monte Carlo methods agreed very well in the central portion of the beam. Outside the useable field area, the differences between the analytical and Monte Carlo results were small but significant, possibly due to the small angle approximation. However, these did not affect the conclusion that a scattering foil system designed for a mono-energetic beam will be suitable for a poly

  16. Dual scattering foil design for poly-energetic electron beams

    International Nuclear Information System (INIS)

    The laser wakefield acceleration (LWFA) mechanism can accelerate electrons to energies within the 6-20 MeV range desired for therapy application. However, the energy spectrum of LWFA-generated electrons is broad, on the order of tens of MeV. Using existing laser technology, the therapeutic beam might require a significant energy spread to achieve clinically acceptable dose rates. The purpose of this work was to test the assumption that a scattering foil system designed for a mono-energetic beam would be suitable for a poly-energetic beam with a significant energy spread. Dual scattering foil systems were designed for mono-energetic beams using an existing analytical formalism based on Gaussian multiple-Coulomb scattering theory. The design criterion was to create a flat beam that would be suitable for fields up to 25 x 25 cm2 at 100 cm from the primary scattering foil. Radial planar fluence profiles for poly-energetic beams with energy spreads ranging from 0.5 MeV to 6.5 MeV were calculated using two methods: (a) analytically by summing beam profiles for a range of mono-energetic beams through the scattering foil system, and (b) by Monte Carlo using the EGS/BEAM code. The analytic calculations facilitated fine adjustments to the foil design, and the Monte Carlo calculations enabled us to verify the results of the analytic calculation and to determine the phase-space characteristics of the broadened beam. Results showed that the flatness of the scattered beam is fairly insensitive to the width of the input energy spectrum. Also, results showed that dose calculated by the analytical and Monte Carlo methods agreed very well in the central portion of the beam. Outside the useable field area, the differences between the analytical and Monte Carlo results were small but significant, possibly due to the small angle approximation. However, these did not affect the conclusion that a scattering foil system designed for a mono-energetic beam will be suitable for a poly

  17. Local histograms and image occlusion models

    CERN Document Server

    Massar, Melody L; Fickus, Matthew; Kovacevic, Jelena

    2011-01-01

    The local histogram transform of an image is a data cube that consists of the histograms of the pixel values that lie within a fixed neighborhood of any given pixel location. Such transforms are useful in image processing applications such as classification and segmentation, especially when dealing with textures that can be distinguished by the distributions of their pixel intensities and colors. We, in particular, use them to identify and delineate biological tissues found in histology images obtained via digital microscopy. In this paper, we introduce a mathematical formalism that rigorously justifies the use of local histograms for such purposes. We begin by discussing how local histograms can be computed as systems of convolutions. We then introduce probabilistic image models that can emulate textures one routinely encounters in histology images. These models are rooted in the concept of image occlusion. A simple model may, for example, generate textures by randomly speckling opaque blobs of one color on ...

  18. Medical image of the week: vascular occlusion

    Directory of Open Access Journals (Sweden)

    Shapiro A

    2014-07-01

    Full Text Available The patient is a 39 year-old woman with no significant past medical history presenting with progressive left hand pain for five days. The patient denied a history of Raynaud’s phenomenon or clotting disorders. She had no radial pulse on presentation and angiogram showed severe complete occlusion of the radial and ulnar arteries (Figures 1 and 2. She had an initial partial response with intra-arterial verapamil and nitroglycerin but her hand ischemia did not improve on heparin or with intra-arterial tissue plasminogen activator. Autoimmune and coagulation work-ups were negative. Her left hand finger necrosis at time of discharge is shown (Figure 3. Further evaluation is ongoing for coagulation disorders.

  19. Robust visual tracking with contiguous occlusion constraint

    Science.gov (United States)

    Wang, Pengcheng; Qian, Weixian; Chen, Qian

    2016-02-01

    Visual tracking plays a fundamental role in video surveillance, robot vision and many other computer vision applications. In this paper, a robust visual tracking method that is motivated by the regularized ℓ1 tracker is proposed. We focus on investigating the case that the object target is occluded. Generally, occlusion can be treated as some kind of contiguous outlier with the target object as background. However, the penalty function of the ℓ1 tracker is not robust for relatively dense error distributed in the contiguous regions. Thus, we exploit a nonconvex penalty function and MRFs for outlier modeling, which is more probable to detect the contiguous occluded regions and recover the target appearance. For long-term tracking, a particle filter framework along with a dynamic model update mechanism is developed. Both qualitative and quantitative evaluations demonstrate a robust and precise performance.

  20. Retinal vein occlusion in Benin City, Nigeria

    Directory of Open Access Journals (Sweden)

    Odarosa M Uhumwangho

    2016-01-01

    Full Text Available Background: Retinal vein occlusion (RVO is the most common occlusive retinal vascular disorder and results in varying degrees of visual loss. Aim: To determine the pattern of presentation, risk factors, and treatment outcomes in a group of patients with RVO seen in a tertiary hospital in Nigeria. Materials and Methods: Medical records of patients who presented to the University of Benin Teaching Hospital, Benin City, Nigeria in whom a diagnosis of RVO was made over a 5 years period were reviewed. Data obtained were analyzed with the GraphPad Instat Software, Inc. version V2.05a program, San Diego, Califonia and a P < 0.05 considered significant. Results: There were 20 patients made of 14 (70.0% males and 6 (30.0% females with a mean age of 62.7 ± 10.4 years. There were 15 (68.2% eyes with central RVO, 3 (13.6% eyes with branch RVO, and 4 (18.2% eyes with hemi RVO. Bilateral involvement occurred in 2 (10.0% patients. Risk factors included hypertension 14 (70.0%, diabetes mellitus 9 (45.0%, and glaucoma 5 (22.7%. Multiple risk factors were present in 14 (70.0% patients. Complications included macula edema 15 (68.2%, retinal neovascularization 5 (22.7%, neovascular glaucoma 3 (13.6%, and vitreous hemorrhage 2 (9.1%. Eyes which had definitive treatment with intravitreal antivascular endothelial growth factors and laser photocoagulation for macula edema and retinal neovascularization, respectively, had better visual acuity compared to eyes which did not receive these treatment, P = 0.002. Conclusion: The incidence and visual loss that occurs from RVO can be reduced by modifying known risk factors and early institution of appropriate therapy for complications that occur.

  1. Coherent spatial and temporal occlusion generation

    Science.gov (United States)

    Klein Gunnewiek, R.; Berretty, R.-P. M.; Barenbrug, B.; Magalhães, J. P.

    2009-02-01

    A vastly growing number of productions from the entertainment industry are aiming at 3D movie theatres. These productions use a two-view format, primarily intended for eye-wear assisted viewing in a well defined environment. To get this 3D content into the home environment, where a large variety of 3D viewing conditions exists (e.g different display sizes, display types, viewing distance), we need a flexible 3D format that can adjust the depth effect. Such a format is the image plus depth format in which a video frame is enriched with depth information of all pixels in the video. This format can be extended with an additional layer for occluded video and associated depth, that contains what is behind objects in the video. To produce 3D content in this extended format, one has to deduce what is behind objects. There are various axes along which this occluded data can be obtained. This paper presents a method to automatically detect and fill the occluded areas exploiting the temporal axis. To get visually pleasing results, it is of utmost importance to make the inpainting globally consistent. To do so, we start by analyzing data along the temporal axis and compute a confidence for each pixel. Then pixels from the future and the past that are not visible in the current frame are weighted and accumulated based on computed confidences. These results are then fed to a generic multi-source framework that computes the occlusion layer based on the available confidences and occlusion data.

  2. Thrombophilic screening in retinal artery occlusion patients

    Directory of Open Access Journals (Sweden)

    Valeria Nagy

    2008-10-01

    Full Text Available Valeria Nagy1, Lili Takacs1, Zita Steiber1, György Pfliegler2, Andras Berta11Department of Ophthalmology, 2Division of Rare Diseases, University of Debrecen Medical and Health Science Center, Debrecen, HungaryBackground: Retinal artery occlusion (RAO is an ischemic vascular damage of the retina, which frequently leads to sudden, mostly irreversible loss of vision. In this study, blood thrombophilic factors as well as cardiovascular risk factors were investigated for their relevance to this pathology. Thrombophilic risk factors so far not evaluated were included in the study.Patients and methods: 28 RAO patients and 81 matched control subjects were examined. From blood samples, protein C, protein S, antithrombinopathy, and factor V (Leiden mutation (FV, factor II gene polymorphism, factor VIII C level, plasminogen activity, lipoprotein(a and fibrinogen levels, hyperhomocysteinemia and presence of anticardiolipin – antiphospholipid antibodies were investigated. Possibly relevant pathologies such as diabetes mellitus, hypertension, and ischemic heart disease were also registered. Statistical analysis by logistic regression was performed with 95% confidence intervals.Results: In the group of patients with RAO only the incidence of hypertension (OR: 3.33, 95% CI: 1.30–9.70, p = 0.014 as an average risk factor showed significant difference, but thrombophilic factors such as hyperfibrinogenemia (OR: 2.9, 95% CI: 1.29–6.57, p = 0.010 and the presence of FV (Leiden mutation (OR: 3.9, 95% CI: 1.43–10.96, p = 0.008 increased the chances of developing this disease.Conclusions: Our results support the assumption that thrombophilia may contribute to the development of RAO besides vascular damage due to the presence of cardiovascular risk factors. Further studies are needed, however, to justify the possible use of secondary prophylaxis in form of anticoagulant/antiplatelet therapy.Keywords: retinal arterial occlusion, risk factors, thrombophilia

  3. A case of cilioretinal artery occlusion resembling hemicentral retinal artery occlusion

    OpenAIRE

    Sato Y; Ohkawara Y; Makino S

    2012-01-01

    Shinji Makino, Yuriko Ohkawara, Yukihiro SatoDepartment of Ophthalmology, Jichi Medical University, Shimotsuke, Tochigi, JapanAbstract: A 77-year-old man presented with an inferior hemivisual field defect in the left eye. Funduscopy revealed well demarcated retinal edema of the superior quadrant resembling hemicentral retinal artery occlusion. Further, the upper and inferior retinal arteries emerged separately from the optic disc. Fluorescein angiography demonstrated a marked filling delay of...

  4. A Case of Incomplete Central Retinal Artery Occlusion Associated with Short Posterior Ciliary Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Shinji Makino

    2013-01-01

    Full Text Available To our knowledge, incomplete central retinal artery occlusion associated with short posterior ciliary artery occlusion is extremely rare. Herein, we describe a case of a 62-year-old man who was referred to our hospital with of transient blindness in his right eye. At initial examination, the patient’s best-corrected visual acuity was 18/20 in the right eye. Fundus examination showed multiple soft exudates around the optic disc and mild macular retinal edema in his right eye; however, a cherry red spot on the macula was not detected. Fluorescein angiography revealed delayed dye inflow into the nasal choroidal hemisphere that is supplied by the short posterior ciliary artery. The following day, the patient’s visual acuity improved to 20/20. Soft exudates around the optic disc increased during observation and gradually disappeared. His hemodynamic parameters revealed subclavian steal syndrome as examined by cervical ultrasonography and digital subtraction angiography. We speculate that his transient blindness was due to ophthalmic artery spasms. In this particular case, spasms of the ophthalmic artery and occlusion of the short posterior ciliary artery occurred simultaneously. As the short posterior ciliary artery branches from the ophthalmic artery, the anatomical location of the lesion might be near the branching of both arteries.

  5. Fabrication and Heat Treatment of Uranium Foil for Mo-99 Production

    International Nuclear Information System (INIS)

    Uranium foil for Mo-99 production is a thin metal sheet, which is produced by fabrication of low enriched uranium (LEU) ingot. In the experiment, ingot fabrication into foil form was done by rolling, started with hot rolling at 615 0C and ended by cold rolling at room temperature. The first hot rolling is applied to uranium ingot of 6,25 mm thickness; the rolling was done in 11 passes with 8% thickness reduction for each pass, and resulted in a foil of 2.6 mm thickness. The second hot rolling is applied to the foil resulted from the first rolling and 26 rolling passes with 8-10% thickness reduction resulted in a foil of 0.26 mm thickness. This foil was subsequently shaped into rectangle and put in an open can for the next process, I.e. both-side cold rolling. The cold rolling process reduced the foil thickness into 0.130 mm and formed preferred orientation grain structure. This foil, which was of 50% thickness reduction, was subsequently subjected to a double heat treatment as to obtain a foil a fine randomly oriented gain structure. The optical metallographic examination of the foil produced by cold rolling series showed that theoptimum condition to produce a foil of a fine randomly oriented grain structure was observed during the double heat treatment

  6. Fabrication of isotopic and natural carbon foils by thermal cracking method and some issues

    International Nuclear Information System (INIS)

    Isotopic and natural carbon foils made by thermal cracking method are used for various purposes in nuclear physics experiments. An apparatus equipped with an oil free vacuum pumping system has been constructed to produce such foils on a resistively heated metallic Ta filament by the thermal cracking method. Properties of the foils such as accessible thickness and area, uniformity, purity and yield in the foil preparation were investigated. We also investigated the following issue during the foil production; when the Ta filament temperature was decreased after the cracking process, the cracked layer sometimes broke into pieces from the filament. Eventually, we could successfully fabricate enriched isotopic 12C foils and natural carbon foils with thicknesses from 0.2 to 5 mg/cm2 and with a dimension of 20 × 20 mm2 or even larger. (author)

  7. Non-uniformity effects of the inter-foil distance on GEM detector performance

    Science.gov (United States)

    Yan, Huang; Han, YI; Zhi-Gang, Xiao; Zhao, Zhang; Wen-Jing, Cheng; Li-Ming, Lü; Wei-Hua, Yan; Ren-Sheng, Wang; Hong-Jie, Li; Yan, Zhang; Li-Min, Duan; Rong-Jiang, Hu; Chen-Gui, Lu; He-Run, Yang; Peng, Ma; Hai-Yan, Gao

    2016-04-01

    The non-uniformity effect of the inter-foil distance has been studied using a gaseous electron multiplication (GEM) detector with sensitive area of 50mm × 50mm. A gradient of the inter-foil distance is introduced by using spacers with different heights at the two ends of the foil gap. While the cluster size and the intrinsic spatial resolution show insignificant dependence on the inter-foil distance, the gain exhibits an approximately linear dependence on the inter-foil distance. From the slope, a quantitative relationship between the change of the inter-foil distance and the change of the gain is derived, which can be used as a method to evaluate the non-uniformity of the foil gap in the application of large-area GEM detectors. Supported by National Natural Science Foundation of China (11375094, U1332207, 11120101004), and by Tsinghua University Initiative Scientific Research Program

  8. The electron capture of H+ ions in solid foils

    Institute of Scientific and Technical Information of China (English)

    杨百方; 缪竞威; 师勉恭; 唐阿友; 杨朝文; 刘晓东

    2002-01-01

    The negative ion yields φ (H-)and the neutral atom yields φ (H) of 0.6, 0.9, 1.2, 1.6 and1.8 MeV H+ projectiles traversing various carbon foils have been measured. The experimental re-sults showed that neither φ (H-) nor φ (H) varies with the dwell time td at the same energy. φ (H) islarger than φ (H-) by about 3-4 orders of magnitude. The charge exchanging between H+ ionsand carbon foils was analyzed. It can be seen that the charge exchange is the most basic proc-ess.The experience formula of σc/σ/has been gotten.

  9. Gas Foil Bearing Technology Advancements for Closed Brayton Cycle Turbines

    Science.gov (United States)

    Howard, Samuel A.; Bruckner, Robert J.; DellaCorte, Christopher; Radil, Kevin C.

    2007-01-01

    Closed Brayton Cycle (CBC) turbine systems are under consideration for future space electric power generation. CBC turbines convert thermal energy from a nuclear reactor, or other heat source, to electrical power using a closed-loop cycle. The operating fluid in the closed-loop is commonly a high pressure inert gas mixture that cannot tolerate contamination. One source of potential contamination in a system such as this is the lubricant used in the turbomachine bearings. Gas Foil Bearings (GFB) represent a bearing technology that eliminates the possibility of contamination by using the working fluid as the lubricant. Thus, foil bearings are well suited to application in space power CBC turbine systems. NASA Glenn Research Center is actively researching GFB technology for use in these CBC power turbines. A power loss model has been developed, and the effects of a very high ambient pressure, start-up torque, and misalignment, have been observed and are reported here.

  10. Wavelength shifting reflector foils for liquid Ar scintillation light

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Manuel [Physik Institut, Universitaet Zuerich (Switzerland); Collaboration: GERDA-Collaboration

    2013-07-01

    Liquid argon is used as a scintillator in several present and upcoming experiments. In Gerda it is used as a coolant, shielding and will be instrumented to become an active veto in Phase II. Its scintillation light has a wavelength of 128 nm, that gets absorbed by quartz. In order to measure the light using photo multiplier tubes (PMT) for cryogenic temperatures which have a quartz window, it is converted to longer wavelength by coated reflector foils. The conversion efficiency and stability of several such coatings was optimized using VM2000 and Tetratex separately as reflector foils. The efficiency has been measured in a liquid Ar set up build especially for this purpose. It employs a 3'' low radioactivity PMT of type R11065-10 from Hamamatsu, the favorite photo sensor candidate to be used in Gerda.

  11. Gaseous Electron Multiplier (GEM), foil holes deformation studies

    CERN Document Server

    Suhaj, Adam; CERN. Geneva. PH Department

    2015-01-01

    GEM detectors play an important role in the upcoming high-luminosity LHC upgrade in 2018 where they will be exposed to high doses of radiation in the muon endcap region. A series of tensile tests were performed on neutron irradiated and non-irradiated GEM foils where the shape of the holes was thoroughly examined. It was found that the GEM foil does not deform much at lower loads but the deformation gets exponentially bigger after applying more than a 60 N force. Both sets of samples behaved similarly at lower loads up to 40 N after which the holes of the irradiated samples started to deform more rapidly than the non-irradiated ones. The failure point of the non-irradiated samples occurred consistently at around 135 N while the irradiated samples experienced failure at around 85 N with two outliers failing at 120 and 135 N.

  12. PERFORMANCE OF LUBRICATING OIL FILM IN ALUMINIUM FOIL ROLLING

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    The surface of the aluminum foil rolled has been observed with microscope on the basis of industrial experiments, and the structure of the surface adsorption film has been analyzed by means of low angle X-ray diffraction. It is advanced that the lubrication in aluminum foil rolling is in the state of thin film lubrication, surface adsorption film is an ordered multi-layered molecule film with more than 7 layers; and the layers of the ordered molecule film is influenced by the concentration of the additive in certain range; the concentration of the additive in oil is the main factor affecting the stability of rolling, controling the concentration of the additive can control the ratio of fluid friction, boundary friction, and local holding-on in deformation zone,thus obtaining good rolling deformation conditions.

  13. Plasma flow switch for foil-implosion experiments

    International Nuclear Information System (INIS)

    Plasma-Flow-Switch (PFS) experiments have been conducted on the 1.5 MJ Pegasus capacitor bank as a part of the opening switch development for the Los Alamos Trailmaster program. The goal of this experiment is an inductive-store, opening switch (for use with an explosive-pulsed-power generator) to drive very high energy foil implosions and generate soft x-ray pulses of ≥ 1 MJ. A shot series is underway to: (1) optimize the PFS for use on Pegasus to study foil-implosion physics issues at drive currents as high as ∼ 10 MA; (2) provide scaling and benchmarking information for the simulations used to design the PFS for explosive generators at much higher energy levels

  14. Plasma flow switch and foil implosion experiments on Pegasus II

    International Nuclear Information System (INIS)

    Pegasus II is the upgraded version of Pegasus, a pulsed power machine used in the Los Alamos AGEX (Above Ground EXperiments) program. A goal of the program is to produce an intense (> 100 TW) source of soft x-rays from the thermalization of the kinetic energy of a 1 to 10 MJ plasma implosion. The radiation pulse should have a maximum duration of several 10's of nanoseconds and will be used in the study of fusion conditions and material properties. The radiating plasma source will be generated by the thermalization of the kinetic energy of an imploding cylindrical, thin, metallic foil. This paper addresses experiments done on a capacitor bank to develop a switch (plasma flow switch) to switch the bank current into the load at peak current. This allows efficient coupling of bank energy into foil kinetic energy

  15. Optical scanning system for quality control of GEM-foils

    International Nuclear Information System (INIS)

    An optical scanning system was commissioned and further developed in the Detector Laboratory of Helsinki Institute of Physics and University of Helsinki. It was designed to automatically scan, perform on-line analysis and to classify the overall quality of GEM-foils especially of the GEM-TPC detectors for Super-FRS at FAIR. The optical scanning system consists of precision positioning table, lighting, optics and operating system with analysis software. It has active scanning area of 95×95 cm2 and it can study this area with the minimum resolution of 128 lp/mm. Performance of the system and first results from the GEM-foil uniformity and quality analysis are presented.

  16. Temperature dependence of the beam-foil interaction

    International Nuclear Information System (INIS)

    The beam energy dependence between 50 and 200 keV of the linear polarization fraction (M/I) of the 2s 1S--3p 1P, 5016 A transition in He I on temperature was measured. The thin carbon exciter foils were heated externally by nichrome resistance elements. The measurements of Hight et al. are duplicated; the energy and current dependences are the same for corresponding between beam heating and external heating. It was also observed that γ, the number of slow secondary electrons produced per incident ion, decreases with increasing foil temperature. These two effects, in conjunction, offer a plausible explanation for the variation of polarization with beam current density. 5 figures

  17. Tilted Foils Nuclear Spin Polarization at REX-ISOLDE

    CERN Document Server

    Törnqvist, Hans Toshihide

    2013-08-08

    This thesis will explain and summarize my work and involvement in experiments aimed at producing nuclear spin polarization of post-accelerated beams of ions with the tilted-foils technique at the REX-ISOLDE linear accelerator at CERN. Polarizing the nuclear spin of radioactive beams in particular may provide access to observables which may be difficult to obtain otherwise. Currently, the techniques commonly employed for nuclear spin polarization are restricted to specific nuclides and experimental measurement techniques. Tilted foils polarization may provide a new tool to extend the range of nuclides that can be polarized and the types of experiments that can be performed. The experiments rely not only on the production but also on the method to measure the degree of attained polarization. Two methods will be treated, based on particle scattering in Coulomb excitation that may be utilized for stable beams, and the $\\beta$-NMR that requires $\\beta$-decaying nuclei. The experimental setups and measurements will...

  18. Evolution of recrystallization textures in high voltage aluminum capacitor foils

    Institute of Scientific and Technical Information of China (English)

    刘楚明; 张新明; 周鸿章; 陈志永; 邓运来; 周卓平

    2001-01-01

    The evolution of recrystallization textures in high voltage aluminum capacitor foils which are produced with a high level of cold reduction was tracked by analysis of microstructure and crystallographic texture. The results show that the deformation textures are mainly composed of S-orientation, Cu-orientation and a little Bs-orientation. During the low temperature stages of final annealing, the iron precipitates first along the sub-grain boundaries, and the Fe concentration in the matrix becomes low. Then, the cube grains nucleate preferably into the sub-grains. At high temperature stages, the cube nuclei can grow preferably because of their 40°〈111〉 orientation relationship to the S orientation, the main component of the rolling texture. Finally, the cube texture is sharply strong and the R orientation is very weak in the foils.

  19. Laser spot welding of cobalt-based amorphous metal foils

    International Nuclear Information System (INIS)

    The results concerning weldability of amorphous alloy (VAC 6025F) in shape of foils and the quality of laser-spot welded joints are presented in this paper. The aim of the research was the production of a high quality welding joint, by preserving the amorphous structure. The quality of the joint was tested by shear strength analysis and microhardness measuring. The metallographic studies were made by using optical microscope and SEM. The results show that (1) overlapped Co based amorphous metals foils can be welded with high-quality by a pulsed Nd: YAG-Laser, but only within a very narrow laser parameter window; (2) the laser welded spots show comparably high strength as the basic material; (3) the structure of the welded spot remains amorphous, so that the same characteristics as the base material can be achieved. (author)

  20. Thrombogenicity tests on ar-irradiated polycarbonate foils

    International Nuclear Information System (INIS)

    Understanding polymer surface properties is extremely important for the most wide range of their applications, from basic coating to the most complex composites and biomaterials. Low energy ion beam irradiation of polymer can improve such surface properties. By modifying its surface biocompatibility, polymers are excellent candidates for biomaterials, due to its malleability and low weight, when compared to metals. In this work, we irradiated 30-μm Bisphenol-A Polycarbonate foils with 23-keV Argon ion beam at six different doses. Aluminium foils were simultaneously irradiated in order to measure the doses by Rutherford Backscattering Spectroscopy. The surface modifications after the argon ion beam irradiation were analyzed by water contact angle measurements and atomic force microscopy. Platelet adhesion tests were used in order to investigate thrombogenicity, showing a growing tendency with the irradiated Argon dose. (author)

  1. Thrombogenicity tests on ar-irradiated polycarbonate foils

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Gustavo F.; Rizzutto, Marcia A.; Silva, Tiago F.; Moro, Marcos V.; Added, Nemitala; Tabacniks, Manfredo H., E-mail: g.ferraz@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Inst. de Fisica; Delgado, Adriana O. [Universidade Federal de Sao Carlos (UFSCAR), Sorocaba, SP (Brazil); Cunha, Tatiana F. [Biosintesis P and D do Brasil, Sao Paulo, SP (Brazil); Higa, Olga Z. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia

    2013-07-01

    Understanding polymer surface properties is extremely important for the most wide range of their applications, from basic coating to the most complex composites and biomaterials. Low energy ion beam irradiation of polymer can improve such surface properties. By modifying its surface biocompatibility, polymers are excellent candidates for biomaterials, due to its malleability and low weight, when compared to metals. In this work, we irradiated 30-μm Bisphenol-A Polycarbonate foils with 23-keV Argon ion beam at six different doses. Aluminium foils were simultaneously irradiated in order to measure the doses by Rutherford Backscattering Spectroscopy. The surface modifications after the argon ion beam irradiation were analyzed by water contact angle measurements and atomic force microscopy. Platelet adhesion tests were used in order to investigate thrombogenicity, showing a growing tendency with the irradiated Argon dose. (author)

  2. Effect of phototherapy with alumunium foil reflectors on neonatal hyperbilirubinemia

    Directory of Open Access Journals (Sweden)

    Tony Ijong Dachlan

    2016-07-01

    Full Text Available Background Neonatal hyperbilirubinemia (NH is one of the most common problems in neonates, but it can be treated with blue light phototherapy. Developing countries with limited medical equipment and funds have difficulty providing effective phototherapy to treat NH, leading to increased risk of bilirubin encephalopathy. Phototherapy with white reflecting curtains can decrease the duration of phototherapy needed to reduce bilirubin levels. Objective To compare the duration of phototherapy needed in neonates with NH who underwent phototherapy with and without aluminum foil reflectors. Methods This open clinical trial was conducted from July to August 2013 at Dr. Hasan Sadikin Hospital, Bandung, Indonesia. The inclusion criteria were term neonates with uncomplicated NH presenting in their first week of life. Subjects were randomized into two groups, those who received phototherapy with or without aluminum foil reflectors. Serum bilirubin is taken at 12th, 24th, 48th hours, then every 24 hours if needed until phototherapy can be stopped according to American Academy of Pediatrics guidelines. The outcome measured was the duration of phototherapy using survival analysis. The difference between the two groups was tested by Gehan method. Results Seventy newborns who fulfilled the inclusion criteria and had similar characteristics were randomized into two groups. The duration of phototherapy needed was significantly less in the group with aluminum foil reflectors than in the group without reflectors [72 vs. 96 hours, respectively, (P<0.01]. Conclusion The required duration of phototherapy with aluminum foil reflectors is significantly less than that of phototherapy without reflectors, in neonates with NH.

  3. Effect of phototherapy with alumunium foil reflectors on neonatal hyperbilirubinemia

    Directory of Open Access Journals (Sweden)

    Tony Ijong Dachlan

    2015-01-01

    Full Text Available Background Neonatal hyperbilirubinemia (NH is one of the most common problems in neonates, but it can be treated with blue light phototherapy. Developing countries with limited medical equipment and funds have difficulty providing effective phototherapy to treat NH, leading to increased risk of bilirubin encephalopathy. Phototherapy with white reflecting curtains can decrease the duration of phototherapy needed to reduce bilirubin levels. Objective To compare the duration of phototherapy needed in neonates with NH who underwent phototherapy with and without aluminum foil reflectors. Methods This open clinical trial was conducted from July to August 2013 at Dr. Hasan Sadikin Hospital, Bandung, Indonesia. The inclusion criteria were term neonates with uncomplicated NH presenting in their first week of life. Subjects were randomized into two groups, those who received phototherapy with or without aluminum foil reflectors. Serum bilirubin is taken at 12th, 24th, 48th hours, then every 24 hours if needed until phototherapy can be stopped according to American Academy of Pediatrics guidelines. The outcome measured was the duration of phototherapy using survival analysis. The difference between the two groups was tested by Gehan method. Results Seventy newborns who fulfilled the inclusion criteria and had similar characteristics were randomized into two groups. The duration of phototherapy needed was significantly less in the group with aluminum foil reflectors than in the group without reflectors [72 vs. 96 hours, respectively, (P<0.01]. Conclusion The required duration of phototherapy with aluminum foil reflectors is significantly less than that of phototherapy without reflectors, in neonates with NH. [Paediatr Indones. 2015;55:18-22.].

  4. Simulation of swift boron clusters traversing amorphous carbon foils

    OpenAIRE

    Heredia Ávalos, Santiago; Abril Sánchez, Isabel; Denton Zanello, Cristian D.; García Molina, Rafael

    2007-01-01

    We use a simulation code to study the interaction of swift boron clusters (Bn+, n=2–6, 14) with amorphous carbon foils. We analyze different aspects of this interaction, such as the evolution of the cluster structure inside the target, the energy and angle distributions at the detector or the stopping power ratio. Our simulation code follows in detail the motion of the cluster fragments through the target and in the vacuum until reaching a detector, taking into account the following interacti...

  5. Central tracking chamber with inflated cathode-strip foils

    International Nuclear Information System (INIS)

    A new cylindrical low-mass central drift chamber has been constructed for the K+ → π+νν experiment at BNL (E787). The chamber consists of 12 layers of axial wire cells and 6 layers of thin cathode-strip foils, four of which are supported by differential gas pressure. The momentum resolution (RMS) for muons and pions in the range 150 to 250 MeV is found to be about 0.9%. (authors)

  6. Optical observations of molecular dissociation in thin foils

    International Nuclear Information System (INIS)

    We have measured the intensity and polarizations of light emitted from atomic excited states of dissociated molecular ions. Using HeH+ projectiles, we have observed factors of 1 to 5 enhancements of the light from n=3, 13P,D states of He I and some He II and H I emissions. Observations of Lyman-α emission after dissociation of H2+ and H3+ show rapid variations in light yield for small internuclear separations at the foil surface

  7. Interaction of positron beams with thin silver foils and surfaces

    International Nuclear Information System (INIS)

    Experimental investigations of positron interactions with solid silver and the necessary platform to analyse the data have been presented. The main objective was to study Ps formation at a Ag(100) surface. The different ingredients of the scenario, including thermalization and diffusion of positrons and emission of Ps, were analysed and quantified in whatever way appropriate. The scattering and possible thermalization were described. The parametrization of Monte-Carlo simulated implantation profiles for semi-infinite materials were presented and the applicability of such profiles to thin foils assessed. The latter was done in conjunction with an analysis of experimental data on thermalization and diffusion in 1900 Aa Ag(100) foils. The necessity for MC simulated rather than parametrized implantation profiles was argued. The velocity of thermally desorbed Ps from a Ag(100) surface at ∼800 K appeared to obey and one-dimensional Maxwell Boltzmann distribution multiplied by a velocity dependent factor. More experimental investigations are needed before firm conclusions can be made on the nature of the emission process. The velocity distribution, though, was found to be near-thermal and indicative of the sample temperature. It has been shown that positrons can be converted into Ps atoms in the transmission geometry of a thin 1900 Aa Ag(100) foil with a high efficiency. Furthermore, 61% of the emitted Ps will have a mean velocity of vz=1.2x105 m/sec and 39% will have a maximum kinetic energy of 1.5 eV (vz=5.1x105 m/sec) at a foil temperature of 800 K, all velocities that are suitable for producing a 'dense' Ps gas target. (EG) 12 refs

  8. Comparison of EXAFS Foil Spectra from Around the World

    International Nuclear Information System (INIS)

    The EXAFS spectra of Cu and Pd foil from many different beamlines and synchrotrons are compared to address the dependence of the amplitude reduction factor (S02) on beamline specific parameters. Even though S02 is the same parameter as the EXAFS coordination number, the value for S02 is given little attention, and is often unreported. The S02 often differs for the same material due to beamline and sample attributes, such that no importance is given to S02-values within a general range of 0.7 to 1.1. EXAFS beamlines have evolved such that it should now be feasible to use standard S02 values for all EXAFS measurements of a specific elemental environment. This would allow for the determination of the imaginary energy (Ei) to account for broadening of the EXAFS signal rather than folding these errors into an effective S02-value. To test this concept, we model 11 Cu-foil and 6 Pd-foil EXAFS spectra from around the world to compare the difference in S02- and Ei-values.

  9. Design of organic complementary circuits and systems on foil

    CERN Document Server

    Abdinia, Sahel; Cantatore, Eugenio

    2015-01-01

    This book describes new approaches to fabricate complementary organic electronics, and focuses on the design of circuits and practical systems created using these manufacturing approaches. The authors describe two state-of-the-art, complementary organic technologies, characteristics and modeling of their transistors and their capability to implement circuits and systems on foil. Readers will benefit from the valuable overview of the challenges and opportunities that these extremely innovative technologies provide. ·         Demonstrates first circuits implemented using specific complementary organic technologies, including first printed analog to digital converter, first dynamic logic on foil and largest complementary organic circuit ·         Includes step-by-step design from single transistor level to complete systems on foil ·         Provides a platform for comparing state-of-the-art complementary organic technologies and for comparing these with other similar technologies, spec...

  10. Production of large screen-mounted aluminium neutralizer foils

    Science.gov (United States)

    Stoner, John O.

    1989-10-01

    In order to convert large-diameter beams of H - to neutral H atoms, aluminum foils having a diameter of 90 cm or more and an areal density of typically 8-12 μg/cm 2 have been proposed. Production of such foils, uniform in thickness to ±20% or better and mounted on thin wire grids, has been accomplished by careful control of substrate preparation, parting-agent application, spatial location of coating filaments, floating speed and temperature, and pickup procedure. Lexan (TM) polycarbonate substrates have been used, because of their uniformity of surface quality. Evaporated NaCl has been used as the parting agent, and an alloy containing 1% silicon rather than pure aluminum has been used as the foil material for greater strength and reliability. To obtain coated areas sufficiently large and uniform, substrates having dimensions of 1.2 m × 1.2 m have been used. A specially configured water tank having a volume of 3.2 m 3 has been built to accept such large substrates. Floating has been done in chilled water to improve its stability, minimize variations in surface tension, and to prevent the development of air bubbles on immersed surfaces. Fractional coverage of better than 95% on meshes having unsupported diameters of greater than 90 cm can now be obtained on a routine basis.

  11. The investigation of electrolytic surface roughening for PCB copper foil

    Science.gov (United States)

    Lee, Shuo-Jen; Liu, Chao-Kai

    2013-10-01

    This study is the application of the principle of electrochemical. The anodic dissolution has no concentration polarization. Hence, electrolyte life is substantially increased. The waste copper is high in ion concentration with a recovery value. As compared with the current PCB chemical pre-treatment method, it may have advantages of cost-saving, improvement of overall efficiency, reduction of production costs and reduction of the amount of waste generated. In the development of the copper foil for electrochemical roughening process, the use of electrolysis reaction affects the copper surface dissolution to form a unique bump coarsening. It will increase in the surface area of the copper foil to improve dry film solder mask and the adhesion between the copper surfaces. Four electrolytes, two neutral salts and two acids, were selected to explore the best of the electrolytic roughening parameters of temperature, time and voltage. The surface roughness and the surface morphology of the copper foil were measured before and after the electrolytic surface roughening. Finally, after repeated experiments, electrolytes A and B copper generates obvious inter-granular corrosion, resulting in a rough surface similar to the chemical pre-treatment. On the other hands, the surface morphology resulted from electrolytes C and D appears more like pitting. Both electrolytic could generate surface roughness of Ra 0.3 um roughened copper surface higher than industrial standard.

  12. Element segregation on the surfaces of pure aluminum foils

    International Nuclear Information System (INIS)

    The surface segregation trend of trace elements in pure aluminum foils was investigated by density functional theory. The model of nine-layer Al(1 0 0) slab substituted partially by trace element atoms was proposed for calculating surface segregation energy. The calculating results show that (i) B, Mg, Si, Ga, Ge, Y, In, Sn, Sb, Pb and Bi exhibit negative segregation energy and possibly move to the surface, while Be, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zr exhibit positive segregation energies and migrated into the bulk; (ii) the segregation energy was found to be related with the covalent radius, the relaxed position at the surface of the substituting atom and the surface energy; (iii) the segregation behavior of trace element generates lots of defects and dislocation, which can increase the initial pitting nucleation sites in the surface of aluminum foils; (iv) the impurity atom concentration was tested with Pb-doped surfaces, the calculated negative segregation energies in all coverage increases rapidly with the Pb coverage. These conclusions are helpful for designing of the chemical composition and to advance the tunnel etching of aluminum foils.

  13. Electroplating of Uranium -Foil Target With Ni And Zn

    International Nuclear Information System (INIS)

    The uranium foil target, which was produced by rolling, was subjected to preparation treatment prior to the electroplating. The electroplating produced certain plate thickness on the foil surface. The electroplating was applied to the uranium foil of 71 mm long and 46 mm wide using plating materials of Ni and Zn. The plating is intended to serve as barrier for fission fragment recoils, which are produced during irradiation. The plate thickness produced by the electroplating was measured by a micrometer and an analytical balance. The electroplating with Ni produced plate-thickness of 8,9 mm when measured by the micrometer, or 11.4 mm when measured by the analytical balance, while the Zn electroplating produced greater plate-thickness, i.e. 16.2 mm by the micrometer measurement or 13.7 mm by the analytical balance measurement. The current efficiency of the electroplating was 62 % for Ni and 80 % for Zn. It was observed that the optimum condition for the electroplating depended on the plating materials, plating time, and current density. The plate-thickness produced under the optimum condition was 7-15 mm at 15 mA/cm2 for Ni and ]0 mA/cm2 for Zn with plating time of 60 minutes

  14. Biomechanics of occlusion--implications for oral rehabilitation.

    Science.gov (United States)

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. PMID:26371622

  15. Modeling self-occlusions in dynamic shape and appearance tracking

    KAUST Repository

    Yang, Yanchao

    2013-12-01

    We present a method to track the precise shape of a dynamic object in video. Joint dynamic shape and appearance models, in which a template of the object is propagated to match the object shape and radiance in the next frame, are advantageous over methods employing global image statistics in cases of complex object radiance and cluttered background. In cases of complex 3D object motion and relative viewpoint change, self-occlusions and disocclusions of the object are prominent, and current methods employing joint shape and appearance models are unable to accurately adapt to new shape and appearance information, leading to inaccurate shape detection. In this work, we model self-occlusions and dis-occlusions in a joint shape and appearance tracking framework. Experiments on video exhibiting occlusion/dis-occlusion, complex radiance and background show that occlusion/dis-occlusion modeling leads to superior shape accuracy compared to recent methods employing joint shape/appearance models or employing global statistics. © 2013 IEEE.

  16. Occlusion detection via structured sparse learning for robust object tracking

    KAUST Repository

    Zhang, Tianzhu

    2014-01-01

    Sparse representation based methods have recently drawn much attention in visual tracking due to good performance against illumination variation and occlusion. They assume the errors caused by image variations can be modeled as pixel-wise sparse. However, in many practical scenarios, these errors are not truly pixel-wise sparse but rather sparsely distributed in a structured way. In fact, pixels in error constitute contiguous regions within the object’s track. This is the case when significant occlusion occurs. To accommodate for nonsparse occlusion in a given frame, we assume that occlusion detected in previous frames can be propagated to the current one. This propagated information determines which pixels will contribute to the sparse representation of the current track. In other words, pixels that were detected as part of an occlusion in the previous frame will be removed from the target representation process. As such, this paper proposes a novel tracking algorithm that models and detects occlusion through structured sparse learning. We test our tracker on challenging benchmark sequences, such as sports videos, which involve heavy occlusion, drastic illumination changes, and large pose variations. Extensive experimental results show that our proposed tracker consistently outperforms the state-of-the-art trackers.

  17. Object tracking by occlusion detection via structured sparse learning

    KAUST Repository

    Zhang, Tianzhu

    2013-06-01

    Sparse representation based methods have recently drawn much attention in visual tracking due to good performance against illumination variation and occlusion. They assume the errors caused by image variations can be modeled as pixel-wise sparse. However, in many practical scenarios these errors are not truly pixel-wise sparse but rather sparsely distributed in a structured way. In fact, pixels in error constitute contiguous regions within the object\\'s track. This is the case when significant occlusion occurs. To accommodate for non-sparse occlusion in a given frame, we assume that occlusion detected in previous frames can be propagated to the current one. This propagated information determines which pixels will contribute to the sparse representation of the current track. In other words, pixels that were detected as part of an occlusion in the previous frame will be removed from the target representation process. As such, this paper proposes a novel tracking algorithm that models and detects occlusion through structured sparse learning. We test our tracker on challenging benchmark sequences, such as sports videos, which involve heavy occlusion, drastic illumination changes, and large pose variations. Experimental results show that our tracker consistently outperforms the state-of-the-art. © 2013 IEEE.

  18. Retinal vein occlusion and the prevalence of lipoprotein abnormalities.

    OpenAIRE

    Dodson, P. M.; Galton, D J; Hamilton, A M; Blach, R K

    1982-01-01

    Ninety-nine patients with retinal vein occlusion (40 with central, 59 with branch vein occlusion) were investigated for the prevalence of associated diseases for comparison with an age-matched control group. There was a significantly increased prevalence of hyperlipidaemia (p less than 0.001) and hypercholesterolaemia (p less than 0.001) in the group with branch retinal vein occlusion and of hyperlipidaemia (p less than 0.001) and hypercholesterolaemia (p less than 0.02) in the group with cen...

  19. [Intestinal occlusion and abdominal compartment syndrome (ACS)].

    Science.gov (United States)

    Stagnitti, Franco

    2009-01-01

    Intestinal occlusion is defined as an independent predictive factor of intra-abdominal hypertension (IAH) which represents an independent predictor of mortality. Baggot in 1951 classified patients operated with intestinal occlusion as being at risk for IAH ("abdominal blow-out"), recommending them for open abdomen surgery proposed by Ogilvie. Abdominal surgery provokes IAH in 44.7% of cases with mortality which, in emergency, triples with respect to elective surgery (21.9% vs 6.8%). In particular, IAH is present in 61.2% of ileus and bowel distension and is responsible for 52% of mortality (54.8% in cases with intra-abdominal infection). These patients present with an increasing intra-abdominal pressure (IAP) which, over 20-25 mmHg, triggers an Abdominal Compartment Syndrome (ACS) with altered functions in some organs arriving at Multiple Organ Dysfunction Syndrome (MODS). The intestine normally covers 58% of abdominal volume but when there is ileus distension, intestinal pneumatosis develops (third space) which can occupy up to 90% of the entire cavity. At this moment, Gastro Intestinal Failure (GIF) can appear, which is a specific independent risk factor of mortality, motor of "Organ Failure". The pathophysiological evolution has many factors in 45% of cases: intestinal pneumatosis is associated with mucosal and serous edema, capillary leakage with an increase in extra-cellular volume and peritoneal fluid collections (fourth space). The successive loss of the mucous barrier permits a bacterial translocation which includes bacteria, toxins, pro-inflammatory factors and oxygen free radicals facilitating the passage from an intra-abdominal to inter-systemic vicious cyrcle. IAH provokes the raising of the diaphragm, and vascular and visceral compressions which induce hypertension in the various spaces with compartmental characteristics. These trigger hypertension in the renal, hepatic, pelvic, thoracic, cardiac, intracranial, orbital and lower extremity areas, giving

  20. Microstructure and Mechanical Properties of AA1235 Aluminum Foil Stocks Produced Directly from Electrolytic Aluminum Melt

    Science.gov (United States)

    Xiong, Hanqing; Yu, Kun; Wen, Li; Yao, Sujuan; Dai, Yilong; Wang, Zhifeng

    2016-02-01

    A new process is developed to obtain high-quality AA1235 aluminum foil stocks and to replace the traditional manufacture process. During the new manufacture process, AA1235 aluminum sheets are twin-roll casted directly through electrolytic aluminum melt (EAM), and subsequently the sheets are processed into aluminum foil stocks by cold rolling and annealing. Microstructure and mechanical properties of the AA1235 aluminum sheets produced through such new process are investigated in each state by optimal microscope, scanning electron microscopy, X-ray diffraction, orientation imaging microscopy, transmission electron microscopy, etc. The results show that compared with the traditional AA1235 aluminum foil stocks produced through re-melted aluminum melt (RAM), the amount of impurities is decreased in the EAM aluminum foil stocks. The EAM aluminum foil stock obtains less β-FeSiAl5 phases, but more α-Fe2SiAl8 phases. The elongation of EAM aluminum foil stocks is improved significantly owing to more cubic orientation. Especially, the elongation value of the EAM aluminum foil stocks is approximately 25 pct higher than that of the RAM aluminum foil stocks. As a result, the EAM aluminum foil stocks are at an advantage in increasing the processing performance for the aluminum foils during subsequent processes.

  1. Bilateral Central Retinal Vein Occlusions Combined with Artery Occlusions in A Patient with Acquired Immune Deficiency Syndrome

    Institute of Scientific and Technical Information of China (English)

    Feng Wen; Xuemei Chen; Haitai Li; Ruiduan Liao; Dezheng Wu

    2002-01-01

    Purpose: This is the first report of a bilateral nonischemic central retinal vein occlusionscombined with artery occlusions in a patient with acquired immune deficiency syndrome(AIDS). Methods: Case report. Results: A 22-year-old Chinese(male) with a positive human immunodeficiency virus(HIV) infection developed bilateral nonischemic central retinal vein occlusions combinedwith artery occlusions and severe vision loss. The manifestations of the fundus andfluorescein angiography were similar in both eyes.Conclusion: This case report provides the evidences that central retinal vein and arteryocclusions are probably part of the spectrum of AIDS vascular diseases.

  2. Vertebrobasilar occlusions. Pathophysiology, diagnostics and treatment

    International Nuclear Information System (INIS)

    Acute vertebrobasilar occlusions (VBO) are dramatic clinical events with a mortality of up to 90% under standard medical treatment. If VBO is suspected a diagnosis of the vessel status has to be achieved immediately. For this purpose CT/CTA and MRI/MRA are equivalent diagnostic tools in the emergency setting. In contrast to the anterior circulation, local endovascular treatment is the established therapy for the posterior circulation as an underlying arteriosclerotic stenosis remains in 50% of the cases after intravenous fibrinolysis. Nevertheless, systemic fibrinolysis is considered the preferred option in cases where a neurointerventional center cannot be reached within a reasonable time frame and the patient can subsequently be transported for local therapy of a residual stenosis in order to prevent reocclusion (''drip and ship''). Profound clinical and pathophysiological knowledge is the absolute prerequisite for the correct application of state-of-the-art neurointerventional therapy. This review paper focuses on the clinical and pathophysiological details that are crucial for decision-making. (orig.)

  3. Fetal MRI in experimental tracheal occlusion

    International Nuclear Information System (INIS)

    Congenital diaphragmatic hernia (CDH) is associated with a high mortality, which is mainly due to pulmonary hypoplasia and secondary pulmonary hypertension. In severely affected fetuses, tracheal occlusion (TO) is performed prenatally to reverse pulmonary hypoplasia, because TO leads to accelerated lung growth. Prenatal imaging is important to identify fetuses with pulmonary hypoplasia, to diagnose high-risk fetuses who would benefit from TO, and to monitor the effect of TO after surgery. In fetal imaging, ultrasound (US) is the method of choice, because it is widely available, less expensive, and less time-consuming to perform than magnetic resonance imaging (MRI). However, there are some limitations for US in the evaluation of CDH fetuses. In those cases, MRI is helpful because of a better tissue contrast between liver and lung, which enables evaluation of liver herniation for the diagnosis of a high-risk fetus. MRI provides the ability to determine absolute lung volumes to detect lung hypoplasia. In fetal sheep with normal and hyperplastic lungs after TO, lung growth was assessed on the basis of cross-sectional US measurements, after initial lung volume determination by MRI. To monitor fetal lung growth after prenatal TO, both MRI and US seem to be useful methods

  4. Leptospirosis and Peripheral Artery Occlusive Disease

    Science.gov (United States)

    Chiu, Chun-Hsiang; Lin, Cheng-Li; Lee, Feng-You; Wang, Ying-Chuan; Kao, Chia-Hung

    2016-01-01

    Abstract Data on the association between peripheral artery occlusive disease (PAOD) and leptospirosis are limited. We conducted a retrospective cohort study for determining whether leptospirosis is one of the possible risk factors for PAOD. Patients diagnosed with leptospirosis by using 2000 to 2010 data from the Taiwan National Health Insurance Research Database. Patients with leptospirosis without a history of PAOD were selected. For each leptospirosis patient, 4 controls without a history of leptospirosis and PAOD were randomly selected and frequency-matched for sex, age, the year of the index date, and comorbidity diseases. The follow-up period was from the time of the initial diagnosis of leptospirosis to the diagnosis date of PAOD, or December 31, 2011. The Cox proportional hazard regression models were used for analyzing the risk of PAOD. During the follow-up period, the cumulative incidence of PAOD was higher among the patients from the leptospirosis cohort than among the nonleptospirosis cohort (log-rank test, P leptospirosis cohort and 81 from the nonleptospirosis cohort were observed with the incidence rates of 2.1 and 1.3 per 1000 person-years, respectively, yielding a crude hazards ratio (HR) of 1.62 (95% confidence interval [CI] = 1.44–1.81) and adjusted HR (aHR) of 1.75 (95% CI = 1.58–1.95). The risk of PAOD was 1.75-fold higher in the patients with leptospirosis than in the general population. PMID:26986166

  5. Clinical trials in branch retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Tandava Krishnan Panakanti

    2016-01-01

    Full Text Available Branch retinal vein occlusion (BRVO is the second most common retinal vascular disorder. The management of macular edema has changed considerably over time. The laser is considered the gold standard treatment for over two decades. However, visual recovery with laser is usually slow and incomplete. The advent of intravitreal agents, specifically anti-vascular endothelial growth factors (VEGF have heralded a new era which promises rapid recovery of vision and quality of vision. Randomized clinical trials have reported optimal results with anti-VEGF agents (ranibizumab, bevacizumab, and aflibercept compared to laser therapy or steroids. However, nearly 50% of the patients require repeat intravitreal anti-VEGF therapy up to 4 years after initiating therapy to sustain the visual gains. The adverse events (systemic and ocular of these agents are minimal. Monotherapy with anti-VEGF agents have been found to provide better results than any combination with laser. This review article summarizes evidence from randomized controlled trials evaluating treatment options for the treatment of macular edema secondary to BRVO with a special focus on anti-VEGF therapy.

  6. Different Occlusal Schemes in a Persistent Protruding Complete Denture Wearer

    Directory of Open Access Journals (Sweden)

    Carolina Mayumi Iegami

    2016-01-01

    Full Text Available Different types of artificial teeth and occlusal designs can be used in complete dentures. Bilateral balanced occlusion, lingualized occlusion, canine guidance, and monoplane are the main occlusal designs; however there is no agreement on which tooth arrangement is ideal for achieving success in complete dentures. This report presents an alternative for persistent involuntary protruding complete denture wearers through the use of artificial teeth with higher cusps. Due to an old and worn pair of complete dentures, the patient had the habit of protruding. New dentures were made with Biotone artificial teeth and in the trial session, the patient would still protrude. A new set was made with Premium artificial teeth, which present higher cusps. With these dentures, the involuntary protrusion did not occur. From the delivery to the follow-up sessions, the patient stopped protruding.

  7. Different Occlusal Schemes in a Persistent Protruding Complete Denture Wearer.

    Science.gov (United States)

    Iegami, Carolina Mayumi; Lopes, Danilo de Melo; Nakamae, Atlas Edson Moleros; Uehara, Priscila Nakasone; Tamaki, Regina

    2016-01-01

    Different types of artificial teeth and occlusal designs can be used in complete dentures. Bilateral balanced occlusion, lingualized occlusion, canine guidance, and monoplane are the main occlusal designs; however there is no agreement on which tooth arrangement is ideal for achieving success in complete dentures. This report presents an alternative for persistent involuntary protruding complete denture wearers through the use of artificial teeth with higher cusps. Due to an old and worn pair of complete dentures, the patient had the habit of protruding. New dentures were made with Biotone artificial teeth and in the trial session, the patient would still protrude. A new set was made with Premium artificial teeth, which present higher cusps. With these dentures, the involuntary protrusion did not occur. From the delivery to the follow-up sessions, the patient stopped protruding. PMID:27069698

  8. Celiac artery stenosis/occlusion treated by interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)], E-mail: osamu-3643ik@do9.enjoy.ne.jp; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)

    2009-08-15

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  9. 21 CFR 878.4020 - Occlusive wound dressing.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing.... Class I (general controls). The device is exempt from the premarket notification procedures in part...

  10. Celiac artery stenosis/occlusion treated by interventional radiology

    International Nuclear Information System (INIS)

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  11. Avoiding occlusal derangement in facial fractures: An evidence based approach

    Directory of Open Access Journals (Sweden)

    Derick Mendonca

    2013-01-01

    Full Text Available Facial fractures with occlusal derangement describe any fracture which directly or indirectly affects the occlusal relationship. Such fractures include dento-alveolar fractures in the maxilla and mandible, midface fractures - Le fort I, II, III and mandible fractures of the symphysis, parasymphysis, body, angle, and condyle. In some of these fractures, the fracture line runs through the dento-alveolar component whereas in others the fracture line is remote from the occlusal plane nevertheless altering the occlusion. The complications that could ensue from the management of maxillofacial fractures are predominantly iatrogenic, and therefore can be avoided if adequate care is exercised by the operating surgeon. This paper does not emphasize on complications arising from any particular technique in the management of maxillofacial fractures but rather discusses complications in general, irrespective of the technique used.

  12. Image Based Solution to Occlusion Problem for Multiple Robots Navigation

    Directory of Open Access Journals (Sweden)

    Taj Mohammad Khan

    2012-04-01

    Full Text Available In machine vision, occlusions problem is always a challenging issue in image based mapping and navigation tasks. This paper presents a multiple view vision based algorithm for the development of occlusion-free map of the indoor environment. The map is assumed to be utilized by the mobile robots within the workspace. It has wide range of applications, including mobile robot path planning and navigation, access control in restricted areas, and surveillance systems. We used wall mounted fixed camera system. After intensity adjustment and background subtraction of the synchronously captured images, the image registration was performed. We applied our algorithm on the registered images to resolve the occlusion problem. This technique works well even in the existence of total occlusion for a longer period.

  13. Occlusal accommodation and mouthguards for prevention of orofacial trauma.

    LENUS (Irish Health Repository)

    Geary, Julian Lindsay

    2009-01-01

    The aim of this study was to investigate the effect of two types of occlusal accommodation on the arch separation in centric and eccentric arch positions and to assess the opposing tooth contacts in professionally made, thermoformed sports mouthguards.

  14. Full Body Pose Estimation During Occlusion using Multiple Cameras

    DEFF Research Database (Denmark)

    Fihl, Preben; Cosar, Serhan

    Automatic estimation of the human pose enables many interesting applications and has therefore achieved much attention in recent years. One of the most successful approaches for estimating unconstrained poses has been the pictorial structures framework. However, occlusions between interacting peo...

  15. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    OpenAIRE

    Mihir Kothari

    2014-01-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  16. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    Directory of Open Access Journals (Sweden)

    Mihir Kothari

    2014-01-01

    Full Text Available Part time occlusion therapy is not reported to cause occlusion (reverse amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  17. Occlusion of Internal Carotid Artery in Kimura's Disease

    OpenAIRE

    Node Yoji; Tomonori Tamaki

    2010-01-01

    We describe a unique case of Kimura's disease in which cerebral infarction was caused by occlusion of the right internal carotid artery. A 25-year-old man with Kimura's disease was admitted to our hospital because of left hemiparesis. Computed tomography and magnetic resonance imaging of the head showed infarction in the right frontal and temporal lobes. Cerebral angiography demonstrated right internal carotid artery occlusion affecting the C1 segment, with moyamoya-like collateral vessels ar...

  18. Pathophysiological aspects of sickle cell vaso-occlusion

    International Nuclear Information System (INIS)

    This book contains over 30 selections. Some of the titles are: An Animal Model for Sickle Cell Vaso-Occlusion: A Study Using NMR and Technetium Imaging; Sickle-Cell Vaso-Occlusion in an Animal Model: Intravital Microscopy and Radionuclide Imaging of Selective Sequestration of Dense Cells; Magnetic Resonance Imaging, Percentage of Dense Cells, and Serum Prostanoids as Tools for Objective Assessment of Pain Crisis: A Preliminary Report; and Painful Crisis and Dense Echinocytes: Effects of Hydration and Vasodilators

  19. Branch retinal vein occlusion associated with quetiapine fumarate

    Directory of Open Access Journals (Sweden)

    Siang Lim

    2011-08-01

    Full Text Available Abstract Background To report a case of branch retinal vein occlusion in a young adult with bipolar mood disorder treated with quetiapine fumarate. Case Presentation A 29 years old gentleman who was taking quetiapine fumarate for 3 years for bipolar mood disorder, presented with sudden vision loss. He was found to have a superior temporal branch retinal vein occlusion associated with hypercholesterolemia. Conclusion Atypical antipsychotic drugs have metabolic side effects which require regular monitoring and prompt treatment.

  20. An adaptive occlusion culling algorithm for use in large ves

    DEFF Research Database (Denmark)

    Bormann, Karsten

    2000-01-01

    The Hierarchical Occlusion Map algorithm is combined with Frustum Slicing to give a simpler occlusion-culling algorithm that more adequately caters to large, open VEs. The algorithm adapts to the level of visual congestion and is well suited for use with large, complex models with long mean free...... line of sight ('the great outdoors'), models for which it is not feasible to construct, or search, a database of occluders to be rendered each frame....

  1. Trauma from occlusion — An orthodontist’s perspective

    OpenAIRE

    R. Saravanan; Babu, Prajeeth J.; Rajakumar, P.

    2010-01-01

    Orthodontic therapy has a big role in the treatment and prevention of malpositions. The signs and symptoms experienced by patients with occlusal trauma are mobility of teeth, temperomandibular joint pain, pain on mastication and periodontal disease. Early diagnosis, proper treatment plan and correction of malocclusion can lead to a successful outcome. Lack of awareness of orthodontic treatment in patients with occlusal trauma can even lead to loss of tooth structure.

  2. Occlusal Caries Depth Measurements Obtained by Five Different Imaging Modalities

    OpenAIRE

    Kamburoğlu, Kıvanç; Hakan KURT; Kolsuz, Eray; ÖZTAŞ, Bengi; Tatar, İlkan; Çelik, Hakan Hamdi

    2010-01-01

    The study aimed to assess the accuracy and reproducibility of occlusal caries depth measurements obtained from different imaging modalities. The study comprised 21 human mandibular molar teeth with occlusal caries. Teeth were imaged using film, CCD, two different cone-beam computerized tomography (CBCT) units and a microcomputer tomography (micro-CT). Thereafter, each tooth was serially sectioned, and the section with the deepest carious lesion was scanned using a high-resolution scanner. Eac...

  3. Compliance of amblyopic patients with occlusion therapy: A pilot study

    OpenAIRE

    Sana Al-Zuhaibi; Iman Al-Harthi; Pascale Cooymans; Aisha Al-Busaidi; Yahya Al-Farsi; Anuradha Ganesh

    2009-01-01

    Background: Increasing evidence shows that good compliance with occlusion therapy is paramount for successful amblyopia therapy. Purpose: To study the degree of compliance and explore factors affecting compliance in patients undergoing occlusion therapy for amblyopia in our practice. Design: Nonrandomized clinical intervention study. Materials and Methods: A total of 31 families with a child (aged 2-12 years), undergoing unilateral amblyopia treatment at the pediatric ophthalmology ...

  4. Effect of Different Occlusion on Facial Expressions Recognition

    OpenAIRE

    Ankita Vyas; Ramchand Hablani

    2014-01-01

    Occlusions around facial parts complicate the task of recognizing facial expressions from their facial images. We propose facial expressions recognition method based on local facial regions, which provides better recognition rate in the presence of facial occlusions. Proposed method uses Uniform Local Binary pattern as a feature extractor, which extract discriminative features from some important parts of facial image. Feature vectors are classified using simplest classifier th...

  5. Plain abdominal film and abdominal ultrasound in intestine occlusion

    International Nuclear Information System (INIS)

    Plain film of the abdomen is widely used in the diagnostic evaluation of intestinal occlusion. Even though this technique can yield a panoramic and high-resolution view of gas-filled intestinal loops, several factors, such as type and duration of occlusion, neurovascular status of the intestine and general patient condition, may reduce the diagnostic specificy of the plain film relative to the organic or functional nature of the occlusion. From 1987 to 1989, fifty-four patients with intestinal occlusion were studied combining plain abdominal film with abdominal ultrasound (US). This was done in order to evaluate whether the additional information obtained from US could be of value in better determining the nature of the ileus. US evaluation was guided by the information already obtained from plain film which better demonstrates gas-filled loops. The results show that in all 27 cases of dynamic ileus (intestinal ischemia, acute appendicitis, acute cholecistis, acute pancreatitis or blunt abdominal trauma) US demonstrates: intestinal loops slightly increased in caliber, with liquid content, or loops containing rare hyperechoic particles, intestinal wall thickening and no peristalsis. In 27 cases of acute, chronic or complicated mechanical ileus (adhesions, internal hernia, intestinal neoplasm, peritoneal seedings) US shows: 1) in acute occlusion: hyperperistaltic intestinal loops containing inhomogeneous liquid; 2) in chronic occlusion: liquid content with a solid echigenic component; 3) in complicated occlusion: liquid stasis, frequent increase in wall thickness, moderate peritoneal effusion and inefficient peristalsis. In conclusion, based on the obtained data, the authors feel that the combination of plain abdominal film and abdominal US can be useful in the work-up of patient with intestinal occlusion. The information provided by US allows a better definition of the nature of the ileus

  6. Multiple extra macular branch retinal vein occlusions in hyperhomocysteinemia

    Directory of Open Access Journals (Sweden)

    Abhijit Diwakar Gore

    2014-01-01

    Full Text Available Hyperhomocysteinemia is a well-known modifiable risk factor for thromboembolism. Retinal vascular occlusion in patients having hyperhomocysteinemia is a known entity, particularly in young patients. However, multiple extra macular branch retinal vein occlusion (BRVO is a rare condition, which can be a presentation of this disease. We present a patient who had multiple extra macular BRVO; on complete systemic workup, he was found to have raised homocysteine levels.

  7. [Occlusal evaluation and design of dental implant therapy in defect dentition].

    Science.gov (United States)

    Li, Y

    2016-04-01

    Implant prosthesis of dentition defect is characteristic of remaining teeth and implants exist at the same time, so the remaining teeth occlusal conditions related to the final occlusal design is to maintain, adjust or re-establish the original dentition occlusion. Therefore, full evaluation of remaining teeth occlusion before restoration, clear prognosis, balancing the occlusal force distribution of natural teeth and implants, and carrying out the predictable occlusal design in the entire process of implant prosthesis can minimize the adverse events after implant prosthesis. Based on the typical cases in this paper, three occlusal design types of occlusal maintain-implant restoration, occlusal adjustment-implant restoration and occlusal reconstruction-implant restoration will be expounded respectively. PMID:27117214

  8. Measurement of the radon diffusion through a nylon foil for different air humidities

    International Nuclear Information System (INIS)

    The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 µm are presented

  9. The stripping foil test stand in the Linac4 transfer line

    International Nuclear Information System (INIS)

    The 160 MeV H- beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H- charge-exchange injection system. It will include a stripping foil, to convert H- into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters. (author)

  10. The stripping foil test stand in the Linac4 transfer line

    CERN Document Server

    Weterings, W; Noulibos, R; Sillanoli, Y; van Trappen, P

    2015-01-01

    The 160 MeV H− beam from the Linac4 (L4) linear accelerator at CERN will be injected into the proton synchrotron booster (PSB) with a new H− charge-exchange injection system. It will include a stripping foil, to convert H− into protons by stripping off the electrons. To gain experience with these very fragile foils, prior to the installation in the PSB, and test different foil materials and thicknesses, lifetimes of the foils, the foil changing mechanism and interlocking functions, a stripping foil test stand will be installed in the L4 transfer line in 2015. This paper describes the mechanical design of the system and discusses the test possibilities and parameters.

  11. Control of Oscillating Foil for Propulsion of Biorobotic Autonomous Underwater Vehicle (AUV

    Directory of Open Access Journals (Sweden)

    S. N. Singh

    2005-01-01

    Full Text Available The paper treats the question of control of a laterally and rotationally oscillating hydrofoil for the propulsion of biologically inspired robotic (biorobotic autonomous underwater vehicles (BAUVs. Sinusoidal oscillations of foils produce maneuvering and propulsive forces. The design is based on the internal model principle. Two springs are used to transmit forces from the actuators to the foil. Oscillating fins produce periodic forces, which can be used for fish-like propulsion and control of autonomous underwater vehicles (AUVs. The equations of motion of the foil include hydrodynamic lift and moment based on linear, unsteady, aerodynamic theory. A control law is derived for the lateral and rotational sinusoidal oscillation of the foil. In the closed-loop system, the lateral displacement and the rotational angle of the foil asymptotically follow sinusoidal trajectories of distinct frequencies and amplitudes independently. Simulation results are presented to show the trajectory tracking performance of the foil for different freestream velocities and sinusoidal command trajectories.

  12. Stabilizing effect of flexibility in the wake of a flapping foil

    CERN Document Server

    Marais, Catherine; Wesfreid, José Eduardo; Godoy-Diana, Ramiro

    2012-01-01

    The wake of a flexible foil undergoing pitching oscillations in a low-speed hydrodynamic tunnel is used to examine the effect of chord-wise foil flexibility in the dynamical features of flapping-based propulsion. We compare the regime transitions in the wake with respect to the case of a rigid foil and show that foil flexibility inhibits the symmetry breaking of the reverse B\\'enard-von K\\'arm\\'an wake reported in the literature. A momentum balance calculation shows the average thrust to be up to three times greater for the flexible foil than for the rigid foil. We explain both of these observations by analyzing the vortex dynamics in the very near wake.

  13. A generalized solution of elasto-aerodynamic lubrication for aerodynamic compliant foil bearings

    Institute of Scientific and Technical Information of China (English)

    YU Lie; QI Shemiao; GENG Haipeng

    2005-01-01

    Although aerodynamic compliant foil bearings are successfully applied in a number of turbo-machineries, theoretical researches on the modeling, performance prediction of compliant foil bearings and the dynamic analysis of the related rotor system seem still far behind the experimental investigation because of structural complexity of the foil bearings. A generalized solution of the elasto-aerodynamic lubrication is presented in this paper by introducing both static and dynamic deformations of foils and solving gas-lubricated Reynolds equations with deformation equations simultaneously. The solution can be used for the calculation of dynamic stiffness and damping, as well as the prediction of static performances of foil bearings. Systematical theories and methods are also presented for the purpose of the prediction of dynamic behavior of a rotor system equipped with foil bearings.

  14. Experimental research of the fine foil explosion dynamics

    International Nuclear Information System (INIS)

    The work is devoted to studying of substances properties at high specific deposit energy using double-frame pulsed backlighting system. The high specific deposit energy was reached at electrical conductor explosion (ECE). Fast mode of ECE was investigated. Fine foils of aluminum, copper, titanium and nickel were used as conductors. Experiments were carried out on the experimental complex consisting of three current generators. The first generator WEG-' was used for explosion of the fine conductors. This generator represents fast capacitor with capacity 250 nF, which was charged to voltage 10 to 30 kV. The investigated conductor was mounted in special holder and the foil contacts with the electrodes were soldered. Two other generators - radiographs XPG-1 and G2 with x-pinch load were used two frame X-ray backlighting imaging. The generators current pulses had amplitude 300 kA and rising time 180 ns with a low inductance load. Four crossed molybdenum wires with diameter of 25 μm were used to form an x-pinch. Using of the x-pinches soft x-ray radiation the images of exploded foil were registered with temporal resolution of 2 ns. The images were detected by a photo film located behind the filter. The x-ray imaging, together with the measurements of the current flowing through a conductor and voltage on the exploded conductor had allowed inferring of the energy deposited into the conductor, delay time of the bubbles formation relative to the moment of current- cutoff and the time dependence of the vapor bubbles quantity

  15. Short-pulse high intensity laser thin foil interaction

    Science.gov (United States)

    Audebert, Patrick

    2003-10-01

    The technology of ultrashort pulse laser generation has progressed to the point that optical pulses larger than 10 J, 300 fs duration or shorter are routinely produced. Such pulses can be focused to intensities exceeding 10^18 W/cm^2. With high contrast pulses, these focused intensities can be used to heat solid matter to high temperatures with minimal hydrodynamic expansion, producing an extremely high energy-density state of matter for a short period of time. This high density, high temperature plasma can be studied by x-ray spectroscopy. We have performed experiments on thin foils of different elements under well controlled conditions at the 100 Terawatt laser at LULI to study the characteristics X-ray emission of laser heated solids. To suppress the ASE effect, the laser was frequency doubled. S-polarized light with a peak intensity of 10^19W/cm^2 was used to minimize resonance absorption. To decrease the effect of longitudinal temperature gradients very thin (800 μ) aluminum foil targets were used. We have also studied the effect of radial gradient by limiting the measured x-ray emission zone using 50μ or 100μ pinhole on target. The spectra, in the range 7-8Å, were recorded using a conical crystal spectrometer coupled to a 800 fs resolution streak camera. A Fourier Domain Interferometry (FDI) of the back of the foil was also performed providing a measurement of the hydrodynamic expansion as function of time for each shot. To simulate the experiment, we used the 1D hydrodynamic code FILM with a given set of plasma parameter (ρ, Te) as initial conditions. The X-ray emission was calculated by post processing hydrodynamic results with a collisional-radiative model which uses super-configuration average atomic data. The simulation reproduces the main features of the experimental time resolved spectrum.

  16. Analysis of cartilage-polydioxanone foil composite grafts.

    Science.gov (United States)

    Kim, James H; Wong, Brian

    2013-12-01

    This study presents an analytical investigation into the mechanical behavior of a cartilage-polydioxanone (PDS) plate composite grafts. Numerical methods are used to provide a first-order, numerical model of the flexural stiffness of a cartilage-PDS graft. Flexural stiffness is a measure of resistance to bending and is inversely related to the amount of deformation a structure may experience when subjected to bending forces. The cartilage-PDS graft was modeled as a single composite beam. Using Bernoulli-Euler beam theory, a closed form equation for the theoretical flexural stiffness of the composite graft was developed. A parametric analysis was performed to see how the flexural properties of the composite model changed with varying thicknesses of PDS foil. The stiffness of the cartilage-PDS composite using 0.15-mm-thick PDS was four times higher than cartilage alone. The composite with a 0.5-mm-thick PDS graft was only 1.7 times stiffer than the composite with the 0.15-mm-thick PDS graft. Although a thicker graft material will yield higher flexural stiffness for the composite, the relationship between composite stiffness and PDS thickness is nonlinear. After a critical point, increments in graft thickness produce gradually smaller improvements in flexural stiffness. The small increase in stiffness when using the thicker PDS foils versus the 0.15 mm PDS foil may not be worth the potential complications (prolonged foreign body reaction, reduction in nutrient diffusion to cartilage) of using thicker artificial grafts. PMID:24327249

  17. Polycarbosilazane passivation on graphite foil used as gasket seal

    International Nuclear Information System (INIS)

    Gasket seals are often used in industry and laboratories where a leak-proof installation is needed in order to avoid loss of products or dangerous materials. Many of products transported inside tubes are at relatively high temperatures excluding polymeric gaskets. In the same line, many of transported materials contain solvents which can attack polymer sealings, therefore limiting their use. An alternative is to use graphite joints as sealings. These joints are a sandwich of graphite foil and stainless steel mesh as forming core. The problem that raises using graphite in contact with steel is that at temperatures of about 500 °C an interdiffusion of carbon on the steel structure occurs which produces adhesion of the graphite gasket on the metallic flange. Therefore this adhesion increases the time to change each gasket, since rests of previously adhered graphite has to be removed from the flange. In order to avoid the adhesion of the graphite on the flange, polycarbosilazane precursor was used as protective finishing on the graphite foil surface. After thermal transformation of the polymer into the corresponding PDC finishing, it acts in two manners: It avoids the direct contact between the carbon and the steel and it allows the sealing of liquids and gases. Adhesion tests were done and showed that the foils passivated with PDCs did not adhere to the steel flange. Moreover, the production methods and products are compatible to industrial environment and processes. The results found here show that the time to change the gasket in industry can be clearly reduced by using the PDC finishing on graphite gasket

  18. Influence of balanced occlusion in complete dentures on the decrease in reduction of an edentulous ridge

    OpenAIRE

    Poštić Srđan D.

    2012-01-01

    Background/Aim. Balanced occlusal arrangement of artificial teeth and balanced occlusion is a specific type of occlusion that preserves the stability of complete dentures. Balanced occlusion comprises realization of tooth contacts at the working side as well as at the balancing side, at the same time. The aim of this study was to assess the influence of balanced occlusal arrangement of artificial teeth on the decrease in reduction of edentulous alveolar ridge. Methods. A longitudinal st...

  19. Zapora mrežničnih ven: Retinal vein occlusion:

    OpenAIRE

    Jaki, Polona; Mavri, Alenka; Štalc, Monika

    2011-01-01

    Retinal vein occlusion is a common disease, especially in the elderly, and is associated with significant visual morbidity, as a consequence of persistent macular oedema, macular ischemia, and in the advanced stages of the disease, due to retinal or iris neovascularisation with vitreal haemorrhages or neovascular glaucoma. There are two types of retinal vein occlusion with respect to the site of occlusion: branch retinal vein occlusion and central retinal vein occlusion. The obstruction is ma...

  20. Microcutting and forming of thin aluminium foils for MEMS

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Mortensen, Dennis; Rombach, Pirmin;

    2011-01-01

    This paper presents a simple procedure for simultaneous cutting and forming of thin Al foils for use in MEMS components. The procedure makes use of scaled down macroscopic sheet forming and cutting techniques by using a hydraulic press, a soft counterpart, and a microfabricated stamp tool. The...... lines. Using the procedure presented in this paper scaled to full 4-8 in. silicon wafer stamp tools, a fast and adequate method for high volume production of MEMS components is obtained. © 2011 American Society of Mechanical Engineers....

  1. Micro-forming of Al-Si foil

    OpenAIRE

    T. Haga; Inoue, K.; H. Watari

    2010-01-01

    Purpose: of this paper is as below. The investigation of the ability of the cold micro-forming of non-metallic glass was purpose. The grain of the rapidly solidified aluminium alloy became fine. The aluminium alloy foil with fine grain was used, and the investigation of the micro-formability of this alloy was investigated. Moreover, increase of the forming speed was investigated. The increase of the forming speed was purpose of this study, too.Design/methodology/approach: The nozzle pressing ...

  2. BEAM-FOIL SPECTROSCOPY OF CHLORINE AND SULFUR IONS

    OpenAIRE

    Frot, D.; Barchewitz, R.; Cukier, M.; Dei-Cas, R.; Bruneau, J

    1987-01-01

    We report on the measurement of spectra of highly stripped chlorine and sulfur ions in the energy ranges of, respectively, 2900 - 3500 eV and 2300 - 2600 eV. The spectra have been obtained after excitation of ions travelling through a thin carbon foil . X-rays emitted by the emerging beam are analyzed with a Johanntype bent crystal spectrometer. The observation angle with respect to the beam axis is 54°. The interpretation of the spectra is performed by comparing experimental results with Mul...

  3. Acceleration region influence on beam parameters on stripping foil

    International Nuclear Information System (INIS)

    Some formulas describing the beam parameters on the stripping foil (SF) as a function of the radial amplitude of betatron oscillations and energy gain are derived. The results computed by these formulas are in good agreement with the results of the numerical calculations. Obtained results show that between the radial emittance and the energy spread exists parametric dependence via amplitude of radial betatron oscillations. This conclusion allows one to create a working diagram of expected beam parameters on SF. This diagram may be particularly useful for the extraction system designers since it gives relationship between parameters considered as the extraction system input parameters. (author)

  4. Synthetic Graphene Grown by Chemical Vapor Deposition on Copper Foils

    Science.gov (United States)

    Chung, Ting Fung; Shen, Tian; Cao, Helin; Jauregui, Luis A.; Wu, Wei; Yu, Qingkai; Newell, David; Chen, Yong P.

    2013-04-01

    The discovery of graphene, a single layer of covalently bonded carbon atoms, has attracted intense interest. Initial studies using mechanically exfoliated graphene unveiled its remarkable electronic, mechanical and thermal properties. There has been a growing need and rapid development in large-area deposition of graphene film and its applications. Chemical vapor deposition on copper has emerged as one of the most promising methods in obtaining large-scale graphene films with quality comparable to exfoliated graphene. In this paper, we review the synthesis and characterizations of graphene grown on copper foil substrates by atmospheric pressure chemical vapor deposition. We also discuss potential applications of such large-scale synthetic graphene.

  5. Laser Proton acceleration from mass limited silicon foils

    Science.gov (United States)

    Zeil, K.; Kraft, S.; Richter, T.; Metzkes, J.; Bussmann, M.; Schramm, U.; Sauerbrey, R.; Cowan, T. E.; Fuchs, J.; Buffechoux, S.

    2009-11-01

    We present recent studies on laser proton acceleration experiments using mass limited silicon targets. Small micro machined silicon foils with 2 μm thickness and 20x20 μm2 to 100x100μm2 size mounted on very tiny stalks were shot with the 100 TW LULI Laser (long pulse 150 fs) and with the new 150 TW DRACO Laser facility (short pulse 30 fs) of the Research Centre Dresden-Rossendorf. The experiments were carried out using high contrast levels. Proton spectra have been measured with magnetic spectrometers and radio chromic film stacks.

  6. Central tracking chamber with inflated cathode-strip foils

    Energy Technology Data Exchange (ETDEWEB)

    Blackmore, E.W.; Bryman, D.A.; Kuno, Y.; Lim, C.; Numao, T.; Padley, P.; Redlinger, G.; Soluk, R. [TRIUMF, Vancouver, BC (Canada); McPherson, R.A. [Joseph Henry Laboratories, Princeton University, Princeton, NJ 08544 (United States)

    1998-02-21

    A new cylindrical low-mass central drift chamber has been constructed for the K{sup +}{yields}{pi}{sup +}{nu} anti {nu} experiment at BNL (E787). The chamber consists of twelve layers of axial wire cells and six layers of thin cathode-strip foils, four of which are supported by differential gas pressure. The momentum resolution (RMS) for muons and pions in the range 150-250 MeV/c is found to be about 0.9%. (orig.). 16 refs.

  7. Optical and scanning electron microscopies in examination of ultrathin foils

    Czech Academy of Sciences Publication Activity Database

    Konvalina, Ivo; Hovorka, Miloš; Fořt, Tomáš; Müllerová, Ilona

    Brno : Institute of Scientific Instruments AS CR, v.v.i, 2010 - (Mika, F.), s. 23-24 ISBN 978-80-254-6842-5. [International Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation /12./. Skalský dvůr (CZ), 31.05.2010-04.06.2010] R&D Projects: GA AV ČR IAA100650902 Institutional research plan: CEZ:AV0Z20650511 Keywords : very low energy scanning transmission electron microscopy * ultrathin foils * laser confocal microscope Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  8. Effect of cerium addition on microstructure and texture of aluminum foil for electrolytic capacitors

    Institute of Scientific and Technical Information of China (English)

    王海燕; 李文学; 任慧平; 黄丽颖; 王向阳

    2010-01-01

    Anode foil of aluminum electrolytic capacitor,which requires large surface area for high capacitance,were prepared by rolling,annealing and electrochemical etching.Effects of cerium addition on the capacitance of aluminum electrolytic capacitors were investigated.Microstructure of the aluminum foil surface was observed by optical microscopy(OM) and scanning electron microscopy(SEM).Electron back scattered diffraction(EBSD) was also employed to reveal texture evolvement of cold-rolled aluminum foil after ann...

  9. Report on Analysis of China’s Aluminum Foil Market in 2014

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    1.China’s domestic production of aluminum foil China is a big country in terms of aluminum foil production,as it owns the highest number of most advanced 2000mm grade foil rolling mills in the world,with about 35 sets(with production capacity of about 400,000 t/a),12more than the combined sum total of all other countries worldwide.According to Antaike’s data,in 2014 China’s

  10. A novel clear foil cushion construction incorporating an additional water layer

    OpenAIRE

    Xie, Fei

    2011-01-01

    Pneumatic clear foil cushion systems, notably as ETFE foil cushions have been developed as an alternative technology to large-scale glass glazing systems for wide-span buildings. The systems display better thermal performance and have advantages of extremely low dead-weight constructions compared to conventional glazing systems, and thereby the increasing popularity of foil cushion cladding systems have been witnessed in the last decades. However due to their lightweight and thinness, the the...

  11. Instability of a Thin Conducting Foil Accelerated by a Finite Wavelength Intense Laser

    OpenAIRE

    Eliasson, Bengt

    2014-01-01

    We derive a theoretical model for the Rayleigh-Taylor (RT)-like instability for a thin foil accelerated by an intense laser, taking into account finite wavelength effects in the laser wave field. The latter leads to the diffraction of the electromagnetic wave off the periodic structures arising from the instability of the foil, which significantly modifies the growth rate of the RT-like instability when the perturbations on the foil have wavenumbers comparable to or larger than the laser wave...

  12. Properties of transition radiation emitted from multiple thin-foil targets

    International Nuclear Information System (INIS)

    Transition Radiation(TR) is expected to be a high brilliant X-ray source because TR X-rays can be produced by low energy electrons compared to synchrotron radiation(SR) in the X-ray region. We measured energy spectra of resonance transition radiation emitted from thin-foil stacks passed by a 130MeV dc electron beam. The results discriminate between intra-foil and inter-foil resonances. (author)

  13. Time Management in Acute Vertebrobasilar Occlusion

    International Nuclear Information System (INIS)

    Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in 77% of patients. The overall mortality was 55%. Major complications were intracranial hemorrhage and peripheral embolism. The time period from symptom onset to intervention showed a strong correlation with the postinterventional NIHSS as well as the patient's age, with the best results in a 4-h interval. Multivariate statistics revealed similarities among the patients. Evaluation of time management in acute VBO by multivariate statistics is a helpful tool for definition of similarities in this patient group. Similarly to the door-to-balloon time for acute coronary interventions, the chances for a good outcome depend on a short time interval between symptom onset and intervention. While the only manipulable time period starts with hospital admission, our results emphasize the necessity of efficient intrahospital workflow.

  14. Metamorphopsia Associated with Branch Retinal Vein Occlusion

    Science.gov (United States)

    Manabe, Koichiro; Tsujikawa, Akitaka; Osaka, Rie; Nakano, Yuki; Fujita, Tomoyoshi; Shiragami, Chieko; Hirooka, Kazuyuki; Uji, Akihito; Muraoka, Yuki

    2016-01-01

    Purpose To apply M-CHARTS for quantitative measurements of metamorphopsia in eyes with acute branch retinal vein occlusion (BRVO) and to elucidate the pathomorphology that causes metamorphopsia. Methods This prospective study consisted of 42 consecutive patients (42 eyes) with acute BRVO. Both at baseline and one month after treatment with ranibizumab, metamorphopsia was measured with M-CHARTS, and the retinal morphological changes were examined with optical coherence tomography. Results At baseline, metamorphopsia was detected in the vertical and/or horizontal directions in 29 (69.0%) eyes; the mean vertical and horizontal scores were 0.59 ± 0.57 and 0.52 ± 0.67, respectively. The maximum inner retinal thickness showed no association with the M-CHARTS score, but the M-CHARTS score was correlated with the total foveal thickness (r = 0.43, p = 0.004), the height of serous retinal detachment (r = 0.31, p = 0.047), and the maximum outer retinal thickness (r = 0.36, p = 0.020). One month after treatment, both the inner and outer retinal thickness substantially decreased. However, metamorphopsia persisted in 26 (89.7%) of 29 eyes. The posttreatment M-CHARTS score was not correlated with any posttreatment morphological parameters. However, the posttreatment M-CHARTS score was weakly correlated with the baseline total foveal thickness (r = 0.35. p = 0.024) and closely correlated with the baseline M-CHARTS score (r = 0.78, p < 0.001). Conclusions Metamorphopsia associated with acute BRVO was quantified using M-CHARTS. Initial microstructural changes in the outer retina from acute BRVO may primarily account for the metamorphopsia. PMID:27123642

  15. Goal-directed mechanisms that constrain retrieval predict subsequent memory for new "foil" information.

    Science.gov (United States)

    Vogelsang, David A; Bonnici, Heidi M; Bergström, Zara M; Ranganath, Charan; Simons, Jon S

    2016-08-01

    To remember a previous event, it is often helpful to use goal-directed control processes to constrain what comes to mind during retrieval. Behavioral studies have demonstrated that incidental learning of new "foil" words in a recognition test is superior if the participant is trying to remember studied items that were semantically encoded compared to items that were non-semantically encoded. Here, we applied subsequent memory analysis to fMRI data to understand the neural mechanisms underlying the "foil effect". Participants encoded information during deep semantic and shallow non-semantic tasks and were tested in a subsequent blocked memory task to examine how orienting retrieval towards different types of information influences the incidental encoding of new words presented as foils during the memory test phase. To assess memory for foils, participants performed a further surprise old/new recognition test involving foil words that were encountered during the previous memory test blocks as well as completely new words. Subsequent memory effects, distinguishing successful versus unsuccessful incidental encoding of foils, were observed in regions that included the left inferior frontal gyrus and posterior parietal cortex. The left inferior frontal gyrus exhibited disproportionately larger subsequent memory effects for semantic than non-semantic foils, and significant overlap in activity during semantic, but not non-semantic, initial encoding and foil encoding. The results suggest that orienting retrieval towards different types of foils involves re-implementing the neurocognitive processes that were involved during initial encoding. PMID:27431039

  16. Role of induced vortex interaction in a semi-active flapping foil based energy harvester

    Science.gov (United States)

    Wu, J.; Chen, Y. L.; Zhao, N.

    2015-09-01

    The role of induced vortex interaction in a semi-active flapping foil based energy harvester is numerically examined in this work. A NACA0015 airfoil, which acts as an energy harvester, is placed in a two-dimensional laminar flow. It performs an imposed pitching motion that subsequently leads to a plunging motion. Two auxiliary smaller foils, which rotate about their centers, are arranged above and below the flapping foil, respectively. As a consequence, the vortex interaction between the flapping foil and the rotating foil is induced. At a Reynolds number of 1100 and the position of the pitching axis at one-third chord, the effects of the distance between two auxiliary foils, the phase difference between the rotating motion and the pitching motion as well as the frequency of pitching motion on the power extraction performance are systematically investigated. It is found that compared to the single flapping foil, the efficiency improvement of overall power extraction for the flapping foil with two auxiliary foils can be achieved. Based on the numerical analysis, it is indicated that the enhanced power extraction, which is caused by the increased lift force, thanks to the induced vortex interaction, directly benefits the efficiency enhancement.

  17. Fission fragment assisted reactor concept for space propulsion: Foil reactor

    Science.gov (United States)

    Wright, Steven A.

    1991-01-01

    The concept is to fabricate a reactor using thin films or foils of uranium, uranium oxide and then to coat them on substrates. These coatings would be made so thin as to allow the escaping fission fragments to directly heat a hydrogen propellant. The idea was studied of direct gas heating and direct gas pumping in a nuclear pumped laser program. Fission fragments were used to pump lasers. In this concept two substrates are placed opposite each other. The internal faces are coated with thin foil of uranium oxide. A few of the advantages of this technology are listed. In general, however, it is felt that if one look at all solid core nuclear thermal rockets or nuclear thermal propulsion methods, one is going to find that they all pretty much look the same. It is felt that this reactor has higher potential reliability. It has low structural operating temperatures, very short burn times, with graceful failure modes, and it has reduced potential for energetic accidents. Going to a design like this would take the NTP community part way to some of the very advanced engine designs, such as the gas core reactor, but with reduced risk because of the much lower temperatures.

  18. Fission fragment assisted reactor concept for space propulsion: Foil reactor

    International Nuclear Information System (INIS)

    The concept is to fabricate a reactor using thin films or foils of uranium, uranium oxide and then to coat them on substrates. These coatings would be made so thin as to allow the escaping fission fragments to directly heat a hydrogen propellant. The idea was studied of direct gas heating and direct gas pumping in a nuclear pumped laser program. Fission fragments were used to pump lasers. In this concept two substrates are placed opposite each other. The internal faces are coated with thin foil of uranium oxide. A few of the advantages of this technology are listed. In general, however, it is felt that if one look at all solid core nuclear thermal rockets or nuclear thermal propulsion methods, one is going to find that they all pretty much look the same. It is felt that this reactor has higher potential reliability. It has low structural operating temperatures, very short burn times, with graceful failure modes, and it has reduced potential for energetic accidents. Going to a design like this would take the NTP community part way to some of the very advanced engine designs, such as the gas core reactor, but with reduced risk because of the much lower temperatures

  19. Personnel neutron dosimetry using electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    A personnel neutron dosimetry system has been developed based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This Cr-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. The dosimetry system employs an electrochemical etch procedure that be used to process large numbers of Cr-39 dosimeters. The etch procedure is suitable for operations where the number of personnel requires that many CR-39 dosimeters be processed. Experience shows that one full-time technician can etch and evaluate 2000 foils per month. The energy response to neutrons is fairly flat from about 80 keV to 3.5 MeV, but drops by about a factor of three in the 13 to 16 MeV range. The sensitivity of the dosimetry system is about 7 tracks/cm2/mrem, with a background equivalent to about 8 mrem for new CR-39 foils. The limit of sensitivity is approximately 10 mrem. The dosimeter has a significant variation in directional dependence, dropping to about 20% at 900. This dosimeter has been used for personnel neutron dosimetry at the Lawrence Livermore National Laboratory for more tha 18 months. 6 refs., 23 figs., 2 tabs

  20. A simple method for the measurement of reflective foil emissivity

    International Nuclear Information System (INIS)

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408

  1. A simple method for the measurement of reflective foil emissivity

    Energy Technology Data Exchange (ETDEWEB)

    Ballico, M. J.; Ham, E. W. M. van der [National Measurement Institute, Lindfield, NSW 2070 (Australia)

    2013-09-11

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

  2. Magnetic moments of mirror nuclei with tilted-foil polarization

    CERN Document Server

    Lindroos, M; Broude, C; Goldring, G; Haas, H; Hass, M; Muellere, L; Pearson, M R; Weissman, L

    2000-01-01

    We report here on an ongoing experimental program initiated at the ISOLDE facility at CERN for the measurement of magnetic moments of short-lived radionuclides, with the emphasis on magnetic moments of mirror nuclei in far-from-stability regions. The nuclei are polarized by the tilted foil technique and the resulting 0-180 degrees beta asymmetry is monitored as a function of RF frequency applied in an NMR setup. In order to achieve sufficiently high energy for transmission through the foils, the experimental setup is mounted on a high voltage platform. The first experiment in this program was the measurement of the beta asymmetry and the NMR resonance for the ground state of /sup 23/Mg (I=3/2, T/sub 1/2 /=11 3 S), yielding mu =-0.533(6) nm. Improvements to the experimental setup are presently being designed, to be used in conjunction with the new developments at ISOLDE for obtaining high charge-state ions from the EBIS (REX- ISOLDE) ion source. This will help pave the way for measurements of magnetic moments ...

  3. Large-area monolayer hexagonal boron nitride on Pt foil.

    Science.gov (United States)

    Park, Ji-Hoon; Park, Jin Cheol; Yun, Seok Joon; Kim, Hyun; Luong, Dinh Hoa; Kim, Soo Min; Choi, Soo Ho; Yang, Woochul; Kong, Jing; Kim, Ki Kang; Lee, Young Hee

    2014-08-26

    Hexagonal boron nitride (h-BN) has recently been in the spotlight due to its numerous applications including its being an ideal substrate for two-dimensional electronics, a tunneling material for vertical tunneling devices, and a growth template for heterostructures. However, to obtain a large area of h-BN film while maintaining uniform thickness is still challenging and has not been realized. Here, we report the systematical study of h-BN growth on Pt foil by using low pressure chemical vapor deposition with a borazine source. The monolayer h-BN film was obtained over the whole Pt foil (2 × 5 cm(2)) under film. The total pressure and orientation of the Pt lattice plane are crucial parameters for thickness control. At high pressure (∼0.5 Torr), thick film was grown on Pt (111), and in contrast, thin film was grown on Pt (001). Our advances in monolayer h-BN growth will play an important role to further develop a high quality h-BN film that can be used for vertical tunneling, optoelectronic devices and growth templates for a variety of heterostructures. PMID:25094030

  4. Tilted Foils Nuclear Spin Polarization and Measurement with Coulomb Excitation

    CERN Document Server

    Törnqvist, Hans; Kowalska, M; Wenander, F

    2012-01-01

    Developing new experimental tools is essential to expand the possibilities of probing the structure of atomic nuclei. The better the currently known properties of nuclei can be manipulated, the more information can be extracted from data collected in nuclear reaction experiments. One property that has been controlled for many years is the nuclear spin, but this has only been viable for a certain set of isotopes with restrictions on for example specific atomic excitation schemes or half-lives. This thesis will provide details on an evaluation project using thin tilted foils after the REX-ISOLDE linac at the CERN-ISOLDE experimental facility, to polarize the spin of nuclei in-flight. The nuclear polarization is then measured with a technique based on Coulomb excitation, which is a flexible and readily available experimental method at ISOLDE with the MINIBALL spectrometer. The tilted foils technique may be beneficial to polarize the nuclear spin of short-lived radioactive beams that can be difficult by other mea...

  5. Flexible foils with electrochromic coatings: science, technology and applications

    International Nuclear Information System (INIS)

    This paper covers a number of aspects of a novel flexible electrochromic foil capable of varying its optical transmittance. The foil includes thin films of tungsten oxide and nickel oxide and an intervening polymer electrolyte serving as lamination material. Concerning scientific aspects, we discuss the prevalent defects in amorphous tungsten oxide and how they lead to a consistent picture of the optical properties of tungsten oxide films as a function of non-stoichiometry and ion intercalation. We also present a refined model for the coloration/bleaching due to proton extraction/insertion in surface sheaths of nano-crystallites of nickel oxide. We then turn to aspects of technology and treat ways to enhance the bleached-state transmittance by mixing the nickel oxide with another oxide having a wide band gap, pre-assembly charge insertion/extraction by facile gas treatments of the films and practical device manufacturing. The final part covers some applications with emphasis on architectural 'smart windows' capable of achieving improved indoor comfort together with significant energy savings due to lowered demands for space cooling. We also touch upon applications concerning eyewear

  6. Imaging natural occlusal caries lesions with optical coherence tomography

    Science.gov (United States)

    Douglas, Shane M.; Fried, Daniel; Darling, Cynthia L.

    2010-02-01

    Several studies have demonstrated that polarization-sensitive optical coherence tomography (PS-OCT) can be used to nondestructively measure the severity of demineralization in the important occlusal surfaces. The purpose of this study was to assess the potential of PS-OCT and OCT methods for the measurement of the depth of natural occlusal carious lesions. Teeth were screened for potential occlusal lesions using near infrared imaging (NIR). A PS-OCT system operating at 1310-nm was used to acquire polarization resolved images of the area of interest on the occlusal surface. The teeth were serial sectioned to 200 μm thickness and examined with polarized light microscopy (PLM) and Transverse Microradiography (TMR) for comparison. The lesion depth measured nondestructively with PS-OCT was compared to the lesion depth measured with PLM and TMR to assess the performance of these methods and determine if polarization sensitivity is required. The lesion depth measured using OCT correlated well with the lesion depths measured with TMR and PLM. Although polarization sensitivity provided better contrast it was not necessary to have polarization sensitivity to identify deep occlusal lesions.

  7. Mechanism of vaso-occlusion in sickle cell anemia

    Science.gov (United States)

    Lei, Huan; Karniadakis, George

    2012-11-01

    Vaso-occlusion crisis is one of the key hallmark of sickle cell anemia. While early studies suggested that the crisis is caused by blockage of a single elongated cell, recent experimental investigations indicate that vaso-occlusion is a complex process triggered by adhesive interactions among different cell groups in multiple stages. Based on dissipative particle dynamics, a multi-scale model for the sickle red blood cells (SS-RBCs), accounting for diversity in both shapes and cell rigidities, is developed to investigate the mechanism of vaso-occlusion crisis. Using this model, the adhesive dynamics of single SS-RBC was investigated in arterioles. Simulation results indicate that the different cell groups (deformable SS2 RBCs, rigid SS4 RBCs, leukocytes, etc.) exhibit heterogeneous adhesive behavior due to the different cell morphologies and membrane rigidities. We further simulate the tube flow of SS-RBC suspensions with different cell fractions. The more adhesive SS2 cells interact with the vascular endothelium and further trap rigid SS4 cells, resulting in vaso-occlusion in vessels less than 15 μm . Under inflammation, adherent leukocytes may also trap SS4 cells, resulting in vaso-occlusion in even larger vessels. This work was supported by the NSF grant CBET-0852948 and the NIH grant R01HL094270.

  8. Tissue microcirculation measured by vascular occlusion test during anesthesia induction.

    Science.gov (United States)

    Kim, Tae Kyong; Cho, Youn Joung; Min, Jeong Jin; Murkin, John M; Bahk, Jae-Hyon; Hong, Deok Man; Jeon, Yunseok

    2016-02-01

    Tissue microcirculation measured by vascular occlusion test is impaired during septic shock. However, it has not been investigated extensively during anesthesia induction. The aim of the study is to evaluate tissue microcirculation during anesthesia induction. We hypothesized that during anesthesia induction, tissue microcirculation measured by vascular occlusion test might be enhanced with peripheral vasodilation during anesthesia induction. We conducted a prospective observational study of 50 adult patients undergoing cardiac surgery. During anesthesia induction, we measured and analyzed tissue oxygen saturation, vascular occlusion test, cerebral oximetry, forearm-minus-fingertip skin temperature gradients and hemodynamic data in order to evaluate microcirculation as related to alterations in peripheral vasodilation as reflected by increased Tforearm-finger thermal gradients. During anesthesia induction, recovery slope during vascular occlusion test and cerebral oxygen saturation increased from 4.0 (1.5) to 4.7 (1.3) % s(-1) (p = 0.02) and 64.0 (10.2) to 74.2 (9.2) % (p Forearm-minus-fingertip skin temperature gradients decreased from 1.9 (2.9) to -1.4 (2.2) °C (p blood pressure and forearm-minus-fingertip skin temperature gradients decrease while cerebral oximetry and vascular occlusion test recovery slope increase. These findings suggest that anesthesia induction increases tissue microcirculation with peripheral vasodilation. PMID:25750016

  9. Interactions between occlusion and human brain function activities.

    Science.gov (United States)

    Ohkubo, C; Morokuma, M; Yoneyama, Y; Matsuda, R; Lee, J S

    2013-02-01

    There are few review articles in the area of human research that focus on the interactions between occlusion and brain function. This systematic review discusses the effect of occlusion on the health of the entire body with a focus on brain function. Available relevant articles in English from 1999 to 2011 were assessed in an online database and as hard copies in libraries. The selected 19 articles were classified into the following five categories: chewing and tongue movements, clenching and grinding, occlusal splints and occlusal interference, prosthetic rehabilitation, and pain and stimulation. The relationships between the brain activity observed in the motor and sensory cortices and movements of the oral and maxillofacial area, such as those produced by gum chewing, tapping and clenching, were investigated. It was found that the sensorimotor cortex was also affected by the placement of the occlusal interference devices, splints and implant prostheses. Brain activity may change depending on the strength of the movements in the oral and maxillofacial area. Therefore, mastication and other movements stimulate the activity in the cerebral cortex and may be helpful in preventing degradation of a brain function. However, these findings must be verified by evidence gathered from more subjects. PMID:22624951

  10. Occlusal Grinding Pattern during Sleep Bruxism and Temporomandibular Disorder

    Directory of Open Access Journals (Sweden)

    Yeni Wijaya

    2013-09-01

    Full Text Available Sleep Bruxism is a significant etiology of temporomandibular disorder (TMD and causes many dental or oral problems such as tooth wear or facet. There is no study analyzing the relationship between sleep bruxism and TMD. Objective: To investigate any relationship between occlusal grinding pattern during sleep bruxism and temporomandibular disorder. Methods: A cross-sectional study involving 30 sleep bruxism patients attended the Faculty Dentistry Universitas Indonesia Teaching Hospital (RSGMP FKG UI. Completion of 2 forms of ID-TMD index and questionnaire from American Academy of Sleep Medicine were done. BruxChecker was fabricated and used for two nights to record the occlusal grinding pattern. The occlusal grinding pattern was categorized into laterotrusive grinding (LG and mediotrusive side. Further divisons of LG were: incisor-canine (IC, incisor-caninepremolar (ICP and incisor-canine-premolar-molar (ICPM. Mediotrusive side was classified as mediotrusive contact (MC and mediotrusive grinding (MG. Results: It was found that occlusal grinding pattern in non-TMD subjects were IC+MC, in subjects with mild TMD were ICP+MG and in subjects with moderate TMD were ICP+MG and ICPM+MG. TMJ was more significantly affected by ICP and ICPM grinding pattern than that of IC. Conclusion: There was a significant relationship between occlusal grinding pattern during sleep bruxism and TMD.DOI: 10.14693/jdi.v20i2.149

  11. Bonding bare die LEDs on PET foils for lighting applications: Thermal design modeling and bonding experiments

    NARCIS (Netherlands)

    Ende, D.A. van den; Kusters, R.H.L.; Cauwe, M.; Waal, A. van der; Brand, J. van den

    2012-01-01

    Integration of LEDs on flexible foil substrates is of interest for flexible lighting applications and flexible photonic devices. A matrix of LEDs on a foil combined with a diffuser can be a potential alternative for flexible OLED lighting devices. Preferably, these LEDs are integrated in an unpackag

  12. Large area flexible lighting foils using distributed bare LED dies on polyester substrates

    NARCIS (Netherlands)

    Ende, D.A. van den; Kusters, R.H.L.; Cauwe, M.; Waal, A. van der; Brand, J. van den

    2013-01-01

    Integration of LEDs on flexible foil substrates is of interest for flexible lighting applications and for backlights for flexible displays. Such a large area lighting device can be made by integrating a matrix of closely spaced LEDs on a flexible foil substrate. Preferably, these LEDs are integrated

  13. Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics

    Science.gov (United States)

    Planinsic, Gorazd; Gojkosek, Mihael

    2011-01-01

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…

  14. Prism foil from an LCD monitor as a tool for teaching introductory optics

    International Nuclear Information System (INIS)

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and image formation in a nontrivial way and are therefore particularly useful for active learning strategies.

  15. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan;

    1992-01-01

    Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...

  16. Current Situation and Development Tendency of China’s Electronic Copper Foil Industry-Part Ⅰ

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    <正>In 2011, in despite of production expansion slowdown of China’s electronic copper foil industry due to global economic downturn, European debt crisis and global inflation, China’s production capacity of copper foil rose through extensive construction of new and extension projects.

  17. Ultrasmooth metallic foils for growth of high quality graphene by chemical vapor deposition

    Science.gov (United States)

    Procházka, Pavel; Mach, Jindřich; Bischoff, Dominik; Lišková, Zuzana; Dvořák, Petr; Vaňatka, Marek; Simonet, Pauline; Varlet, Anastasia; Hemzal, Dušan; Petrenec, Martin; Kalina, Lukáš; Bartošík, Miroslav; Ensslin, Klaus; Varga, Peter; Čechal, Jan; Šikola, Tomáš

    2014-05-01

    Synthesis of graphene by chemical vapor deposition is a promising route for manufacturing large-scale high-quality graphene for electronic applications. The quality of the employed substrates plays a crucial role, since the surface roughness and defects alter the graphene growth and cause difficulties in the subsequent graphene transfer. Here, we report on ultrasmooth high-purity copper foils prepared by sputter deposition of Cu thin film on a SiO2/Si template, and the subsequent peeling off of the metallic layer from the template. The surface displays a low level of oxidation and contamination, and the roughness of the foil surface is generally defined by the template, and was below 0.6 nm even on a large scale. The roughness and grain size increase occurred during both the annealing of the foils, and catalytic growth of graphene from methane (≈1000 °C), but on the large scale still remained far below the roughness typical for commercial foils. The micro-Raman spectroscopy and transport measurements proved the high quality of graphene grown on such foils, and the room temperature mobility of the graphene grown on the template stripped foil was three times higher compared to that of one grown on the commercial copper foil. The presented high-quality copper foils are expected to provide large-area substrates for the production of graphene suitable for electronic applications.

  18. Foil Cooling for the Rep-Rated Electron Beam Pumped Electra Laser

    Science.gov (United States)

    Giuliani, J. L.; Hegeler, F.; Wolford, M. F.; Abdel-Khalik, S.

    2005-10-01

    The Electra program at the Naval Research Laboratory is developing the science and technologies for implementation of krypton-fluoride (KrF) lasers in inertial fusion energy. Large aperture KrF lasers are pumped by electron beams which transit a foil separating the gas target at >=1 atm pressure from the vacuum diode. A fraction of the beam energy is deposited in the foil and thus long term (>=10^8 shots), rep-rated (5 Hz) operation requires active cooling of the foil to prevent thermal yield relaxation and cycling fatigue. This paper will report on experimental data and theoretical analysis of two diverse approaches to foil thermal management: convective and conductive cooling. Convective turbulent cooling has been operational on the Electra main amp through the use of oscillating louvers within a gas recirculator containing the pumped lasing region. At 5 Hz the foil temperature (Tf) can be maintained at ˜400 ^oC for a 1 mil SS foil. Conduction cooling provides the simplest configuration with only the need for water channels in the ribs of the hibachi. For a 1 mil Al foil, Tf is predicted to be ˜140 ^oC at 5 Hz. Comparison of experimental and theoretical results and advanced foil materials will be discussed.

  19. Effect of microstructure on specific capacitance of AA3003 aluminum alloy foils

    Institute of Scientific and Technical Information of China (English)

    张新明; 靳丽; 肖亚庆; 蹇雄

    2003-01-01

    By means of OM, EDS, SEM and TEM, the effect of microstructures of AA3003 aluminum alloy foils on specific capacitance was investigated . The results show that the specific capacitance of the cathode aluminum foils depends on the microstructures of the foils, including intermetallic compound (Mn,Fe)Al6 and Al matrix, tangled dislocations in the regions adjacent to the intermetallic particles, and smaller and dispersed particles. Because the dislocation interaction with larger particles gives rise to high local lattice curvature in the matrix, which can be preferentially dissolved when etched, which results in serious remnant metal powders on the foil surface. Solid solution at 630 ℃, quenching in water and aging at 60 ℃ may increase the number of the second phase particles, and reduce the large particles, so that the capacitance of the cathode foils becomes higher and almost no powders remain on the surface of the foil. By means of aging after quenching, the precipitated particles and etch-pit density in the foil increase obviously, therefore the favourable microstructures can be produced to improve the specific capacitance of the foils.

  20. Optical transition radiation from a thin carbon foil: a beam profile monitor for the SLC

    International Nuclear Information System (INIS)

    This memo considers placement of an ultra thin carbon foil into the SLC beam. Transition radiation light would be emitted from the surface of the foil. The optical spot from the foil could be viewed with a microscope objective lens and registered with an image detector. Multiple scattering for the foil thicknesses necessary will not affect the beam emittance. Calculations show that a thin carbon foil can withstand the electron beam if the electron beam is larger than 10 μm in size. There are many possible radiation mechanisms from a foil - bremsstrahlung, black body temperature radiation, Cerenkov light, scintillation light, and transition radiation. Transition radiation is apparently dominant. It is proposed to use thin carbon foils, 75 to 150 A thick. Calculations indicate that 5 x 1010 beam electrons will radiate a useable number of optical photons. Specifically with 150 A foils the fractional yield of useful optical photons is 10-3 photons per incident electron 5 x 10+7 optical photons imaged upon an image plane. Spread these photons over a 32 x 32 pixel CCD and one has the readout system of a monitor

  1. Flexible AMOLED display on polyethylene napthalate (PEN) foil with metal-oxide TFT backplane

    NARCIS (Netherlands)

    Tripathi, A.K.; Putten, B. van der; Steen, J.L. van der; Tempelaars, K.; Cobb, B.; Ameys, M.; Ke, T.H.; Myny, K.; Steudel, S.; Nag, M.; Schols, S.; Vicca, P.; Smout, S.; Genoe, J.; Heremans, P.; Yakimets, I.; Gelinck, G.H.

    2012-01-01

    We present a top emitting monochrome AMOLED display with 85dpi resolution using an amorphous Indium-Gallium-Zinc-Oxide (IGZO) TFT backplane on PEN-foil. Maximum processing temperature was limited to 150 °C in order to ensure an overlay accuracy < 3μm on PEN foil. The backplane process flow is based

  2. On the preparation of self-supporting zinc target foils of separated isotopes

    International Nuclear Information System (INIS)

    This is the second report on the practical method of preparation of targets for nuclear experiments following the previous one (INS-TL-121 (in Japanese)). In this report, a method is described for the preparation of self-supporting zinc foils from ZnO. The thicknesses of target foils and their uniformity were measured with an α-ray thickness gauge. (auth.)

  3. Production of thin carbon stripper foils using heated-substrates in a cathodic arc deposition system

    International Nuclear Information System (INIS)

    The lifetime of carbon stripper foil can have a marked impact on the successful running of a beam line. Standard techniques for production of carbon stripper foils include evaporation of carbon (ec) and laser-pulsed ablation (Ipa). Recent work by a using Ipa has been successful in substantially increasing the lifetime of a very thin foil. The suspected mechanism for the increased lifetime of the foil is that the amorphous carbon foil is density-matched to that of graphite (around 2.26g/cc). In this work, we attempt to reproduce this result by producing carbon stripper foils with a mass-density similar to graphite using a cathodic arc deposition system. The cathodic arc is well known for the production of tetrahedral amorphous carbon: a high density, high stress form of carbon with over 90% sp3-like bonds; to reduce the density of the carbon and promote more graphitic structure, a high bias was initially attempted but this proved unsuccessful. Another method is to use a heated-substrate holder to reduce compressive stress within the deposited film. The performance of the density-matched carbon stripper foils and the implications for future production of high-quality carbon stripper foils in our laboratory will be discussed. (authors)

  4. New methodology for studying the structural ecology of occlusal caries

    DEFF Research Database (Denmark)

    Dige, Irene; Grønkjær, Lene; Nyvad, Bente

    Microbiological studies of occlusal dental biofilms have hitherto been hampered by inaccessibility to the sampling site and demolition of the original biofilm architecture. The aim of the present study was to explore the spatial distribution of bacterial taxa in vivo at various stages of occusal...... caries, applying a new methodology involving preparation of embedded hard dental tissue slices for fluorescence in situ hybridization (FISH) and confocal microscopy. 11 extracted teeth were included in the study and classified according to their occlusal caries status (active/inactive/sound; cavitated...... related to histological features of lesion penetration. The sites showed distinct differences in the bacterial composition and fluorescence intensity between different ecological niches in occlusal caries. Biofilm observed along the entrance of fissures showed an inner layer of microorganisms organized in...

  5. Diffusion tensor imaging patients with major cerebral artery occlusive disease

    International Nuclear Information System (INIS)

    Diffusion tensor (DT) imaging provides quantitative information about the magnitude and the directionality (anisotropy) of water diffusion in vivo and can detect pathologic changes in brain ischemia. This study tried to detect ischemic brain damage using DT imaging in patients with symptomatic chronic major cerebral artery occlusive disease. DT imaging was performed using a 3.0 Tesla magnetic resonance (MR) scanner in 50 patients with unilateral internal carotid artery or middle cerebral artery stenosis or occlusion, who had no obvious infarct lesions on conventional MR imaging. Thirty-three patients underwent DT imaging before and after vascular reconstruction surgery. Fractional anisotropy (FA) was calculated in the middle cerebral artery territory. Preoperative FA values in the ipsilateral side were significantly lower than those in the contralateral side. After surgery, the FA value was significantly increased. DT imaging may indicate ischemic brain damage, not visualized by conventional MR imaging, in patients with major cerebral artery occlusive disease. (author)

  6. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    KAUST Repository

    Schott, M.

    2013-06-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  7. Hierarchical Template Matching for Robust Visual Tracking with Severe Occlusions

    Institute of Scientific and Technical Information of China (English)

    Lizuo Jin; Tirui Wu; Feng Liu; Gang Zeng

    2012-01-01

    To tackle the problem of severe occlusions in visual tracking, we propose a hierarchical template-matching method based on a layered appearance model. This model integrates holistic- and part-region matching in order to locate an object in a coarse-to-fine manner. Furthermore, in order to reduce ambiguity in object localization, only the discriminative parts of an object' s appearance template are chosen for similarity computing with respect to their cornerness measurements. The similarity between parts is computed in a layer-wise manner, and from this, occlusions can be evaluated. When the object is partly occluded, it can be located accurately by matching candidate regions with the appearance template. When it is completely occluded, its location can be predicted from its historical motion information using a Kalman filter. The proposed tracker is tested on several practical image sequences, and the experimental results show that it can consistently provide accurate object location for stable tracking, even for severe occlusions.

  8. Lead foil in dental X-ray film: Backscattering rejection or image intensifier?

    International Nuclear Information System (INIS)

    Dental X-ray films are still largely used due to sterilization issues, simplicity and, mainly, economic reasons. These films almost always are double coated (double emulsion) and have a lead foil in contact with the film for X-ray backscattering rejection. Herein we explore the use of the lead foil as an image intensifier. In these studies, spatial resolution was investigated when images were acquired on the dental X-ray films with and without the lead foil. Also, the lead foil was subjected to atomic analysis (fluorescent measurements) and structure analysis (X-ray diffraction). We determined that the use of the lead foil reduces the exposure time, however, does not affect the spatial resolution on the acquired images. This suggests that the fluorescent radiation spread is smaller than the grain sizes of the dental X-ray films

  9. Instability of a Thin Conducting Foil Accelerated by a Finite Wavelength Intense Laser

    CERN Document Server

    Eliasson, Bengt

    2014-01-01

    We derive a theoretical model for the Rayleigh-Taylor (RT)-like instability for a thin foil accelerated by an intense laser, taking into account finite wavelength effects in the laser wave field. The latter leads to the diffraction of the electromagnetic wave off the periodic structures arising from the instability of the foil, which significantly modifies the growth rate of the RT-like instability when the perturbations on the foil have wavenumbers comparable to or larger than the laser wavenumber. In particular, the growth rate has a local maximum at a perturbation wavenumber approximately equal to the laser wavenumber. The standard RT instability, arising from a pressure difference between the two sides of a foil, is approximately recovered for perturbation wavenumbers smaller than the laser wavenumber. Differences in the results for circular and linear polarization of the laser light are pointed out. The model has significance to radiation pressure acceleration of thin foils and to laser-driven inertial c...

  10. Foil assisted replica molding for fabrication of microfluidic devices and their application in vitro.

    Science.gov (United States)

    Micheal, Issac J; Vidyasagar, Aditya J; Bokara, Kiran Kumar; Mekala, Naveen Kumar; Asthana, Amit; Rao, Ch Mohan

    2014-10-01

    We present a simple, rapid, benchtop, Foil Assisted Rapid Molding (FARM) method for the fabrication of microfluidic devices. This novel technique involves the use of aluminium foil, pen and an X-Y plotter to create semi-circular or plano-concave, shallow microchannels. It is an easy do-it-yourself (DIY) technique for creating a microfluidic device in three simple steps: (1) create a channel design using the CAD software, (2) plot the patterns on aluminium foil and (3) use the reverse of the engraved foil as a mold to create microfluidic devices. In this report, we present a detailed study of the proposed method by varying a range of parameters such as foil thickness, tip material, and tip sizes and by investigating their effect on the creation of channels with varying geometry. Furthermore, we demonstrated the cytocompatibility of these devices in vitro. PMID:25102283

  11. Lead foil in dental X-ray film: Backscattering rejection or image intensifier?

    Energy Technology Data Exchange (ETDEWEB)

    Hönnicke, M.G., E-mail: marcelo.honnicke@unila.edu.br [Universidade Federal da Integração Latino-Americana, Foz do Iguaçu (Brazil); Delben, G.J. [Faculdade de Tecnologia Tupy, Curitiba (Brazil); Godoi, W.C. [Universidade Tecnológica Federal do Paraná, Curitiba (Brazil); Swinka-Filho, V. [Instituto de Tecnologia para o Desenvolvimento – LACTEC, Curitiba (Brazil)

    2014-11-01

    Dental X-ray films are still largely used due to sterilization issues, simplicity and, mainly, economic reasons. These films almost always are double coated (double emulsion) and have a lead foil in contact with the film for X-ray backscattering rejection. Herein we explore the use of the lead foil as an image intensifier. In these studies, spatial resolution was investigated when images were acquired on the dental X-ray films with and without the lead foil. Also, the lead foil was subjected to atomic analysis (fluorescent measurements) and structure analysis (X-ray diffraction). We determined that the use of the lead foil reduces the exposure time, however, does not affect the spatial resolution on the acquired images. This suggests that the fluorescent radiation spread is smaller than the grain sizes of the dental X-ray films.

  12. Endovascular Treatment of Veno-Occlusive Behcet’s Disease

    International Nuclear Information System (INIS)

    Purpose: To retrospectively evaluate the outcome of endovascular treatments for patients with chronic veno-occlusive disease in different vascular beds secondary to Behcet’s disease (BD). There are few case reports on the subject, and this is the largest study to date. Materials and Methods: From January 2001 through October 2009, chronic venous occlusions were treated in 10 patients (all male [age range 18–76 years]) with BD using percutaneous transluminal angioplasty and/or stent placement. All patients were symptomatic and had chronic iliofemoral deep venous thrombosis (DVT; n = 5), central venous occlusion (n = 3), or Budd–Chiari syndrome (BCS; n = 2). All patients met criteria of the International Study Group on Behcet’s Disease. Results: Two of five patients with DVT had unsuccessful recanalization attempts. Three patients had successful recanalization with stent placement. All three veins were occluded within 1 month with unsuccessful reinterventions. Three patients with chronic central venous occlusion had successful recanalization with percutaneous transluminal angioplasty (n = 1) and stent placement (n = 2). Two patients had reocclusion with successful reintervention. Two BCS patients had successful treatment with stent placements. Overall technical success was 69%, and no procedural complications were encountered. None of the patients with chronic DVT had patent veins; however, all patients with central venous occlusion or BCS had patent veins on color Doppler ultrasonography at follow-up ranging from 3 to 48 months after intervention. Conclusion: Endovenous treatment for chronic iliofemoral DVT due to BD had a poor outcome. However, long-term outcome after endovenous treatment for upper-extremity central venous occlusion and BCS syndrome was good.

  13. Standard test methods of tension testing of metallic foil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1993-01-01

    1.1 These test methods cover the tension testing of metallic foil at room temperature in thicknesses less than 0.006 in. (0.150 mm). Note 1—Exception to these methods may be necessary in individual specifications or test methods for a particular material. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Underwater explosive welding of thin tungsten foils and copper

    International Nuclear Information System (INIS)

    Highlights: → Underwater explosive welding was used to clad tungsten and copper. → The preset inclination was varied and the microstructure was observed. → Microstructure reveals a clear wavy interface for higher preset inclination. → High pressure and high strain rate leads to plastic flow of tungsten. - Abstract: This study demonstrates the ability to clad pure tungsten foils on copper plate using underwater shock waves generated by the detonation of explosive. Microstructural characterization revealed that a higher preset inclination results in wavy morphology. Weld formed at lower inclination exhibit a planar interfacial layer comprising fine grained particles of both components. The plastic flow of tungsten is ascribed to the synergistic influence of high pressure and high strain rate at the collision point.

  15. Silver-Rutile Schottky Diode Fabricated on Oxidized Titanium Foil

    International Nuclear Information System (INIS)

    The fabrication and characterization of a gas sensing Ag-TiO2 Schottky diode are reported. The fabricated Ag-TiO2-Ti structure, formed by sintering silver nanoparticles on the thermally oxidized titanium foil, demonstrated I-V characteristics of a typical Schottky diode at elevated temperatures up to 500 deg. C. The I-V characteristics of these devices strongly depended on the concentration level of the reducing gas contaminants in the surrounding atmosphere. The samples performed like high-barrier Schottky diodes in clean air, while behaved as ohmic contacts in highly reducing atmospheres. Different concentration levels of the examined alcohol vapours could increase the reverse current of the diodes up to 5 orders of magnitude. The measured electronic features of the device were described via an energy band diagram model.

  16. Underwater explosive welding of thin tungsten foils and copper

    Energy Technology Data Exchange (ETDEWEB)

    Manikandan, P., E-mail: manikandan_exp@yahoo.com [Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Lee, J.O.; Mizumachi, K. [Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Mori, A. [Department of Mechanical Engineering, Sojo University, 4-22-1 Ikeda, Kumamoto 860-0082 (Japan); Raghukandan, K. [Department of Manufacturing Engineering, Annamalai University, Annamalainagar, Cuddalore District, Tamilnadu 608 002 (India); Hokamoto, K. [Shock Wave and Condensed Matter Research Center, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan)

    2011-11-15

    Highlights: > Underwater explosive welding was used to clad tungsten and copper. > The preset inclination was varied and the microstructure was observed. > Microstructure reveals a clear wavy interface for higher preset inclination. > High pressure and high strain rate leads to plastic flow of tungsten. - Abstract: This study demonstrates the ability to clad pure tungsten foils on copper plate using underwater shock waves generated by the detonation of explosive. Microstructural characterization revealed that a higher preset inclination results in wavy morphology. Weld formed at lower inclination exhibit a planar interfacial layer comprising fine grained particles of both components. The plastic flow of tungsten is ascribed to the synergistic influence of high pressure and high strain rate at the collision point.

  17. Aerodynamic analysis of flapping foils using volume grid deformation code

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jin Hwan [Seoul National University, Seoul (Korea, Republic of); Kim, Jee Woong; Park, Soo Hyung; Byun, Do Young [Konkuk University, Seoul (Korea, Republic of)

    2009-06-15

    Nature-inspired flapping foils have attracted interest for their high thrust efficiency, but the large motions of their boundaries need to be considered. It is challenging to develop robust, efficient grid deformation algorithms appropriate for the large motions in three dimensions. In this paper, a volume grid deformation code is developed based on finite macro-element and transfinite interpolation, which successfully interfaces to a structured multi-block Navier-Stokes code. A suitable condition that generates the macro-elements with efficiency and improves the robustness of grid regularity is presented as well. As demonstrated by an airfoil with various motions related to flapping, the numerical results of aerodynamic forces by the developed method are shown to be in good agreement with those of an experimental data or a previous numerical solution

  18. Foil-like manganin gauges for dynamic high pressure measurements

    Science.gov (United States)

    Duan, Zhuoping; Liu, Yan; Pi, Aiguo; Huang, Fenglei

    2011-07-01

    Foil-like manganin gauges with a variety of shapes used in different ranges of pressure for the one-dimensional strain mode and axisymmetric strain mode were designed for measuring the detonation pressures of explosives and high shock pressure in materials. In the stress range of 0-53.5 GPa, the pressure-piezoresistance relationships of the manganin gauges were calibrated by the light gas gun and the planar lens of explosive. The piezoresistance coefficients were obtained in different ranges of pressure. To verify the coefficients, the detonation pressure (CJ pressure) of TNT explosive was measured by the manganin gauges, which give similar CJ pressure values to those reported by Zhang et al (2009 Detonation Physics (Beijing: Ordnance Industry Press)) with the maximum relative deviation being less than 3%.

  19. Foil-like manganin gauges for dynamic high pressure measurements

    International Nuclear Information System (INIS)

    Foil-like manganin gauges with a variety of shapes used in different ranges of pressure for the one-dimensional strain mode and axisymmetric strain mode were designed for measuring the detonation pressures of explosives and high shock pressure in materials. In the stress range of 0–53.5 GPa, the pressure–piezoresistance relationships of the manganin gauges were calibrated by the light gas gun and the planar lens of explosive. The piezoresistance coefficients were obtained in different ranges of pressure. To verify the coefficients, the detonation pressure (CJ pressure) of TNT explosive was measured by the manganin gauges, which give similar CJ pressure values to those reported by Zhang et al (2009 Detonation Physics (Beijing: Ordnance Industry Press)) with the maximum relative deviation being less than 3%

  20. Flow structures in the wake of heaving and pitching foils

    Science.gov (United States)

    Najdzin, Derek; Pardo, Enrique; Leftwich, Megan C.; Bardet, Philippe M.

    2012-11-01

    A 10-bar mechanism drives a cambering hydrofoil in an oscillatory heaving and pitching motion that replicates the flapping motion of a dolphin tail. The mechanism sits on a force-balance with six strain gages that together measure the forces and moments experienced by the fin during an oscillation. Planar Laser-Induced Fluorescence is used to image the flow structures created downstream of the cambering fin for a range of Reynolds and Strouhal numbers. The images are taken in the mid-plane, parallel to the bottom of the water tunnel. These results are compared to a rigid foil at matching conditions to investigate the role of camber changes during the flapping cycle.

  1. Electron microscope observation of single - crystalline beryllium thin foils

    International Nuclear Information System (INIS)

    Thin foils prepared from single crystalline beryllium simples deformed at room temperature, have been observed by transmission electron microscopy. The various deformation modes have been investigated separately, from their early stages and their characteristic dislocation configurations have been observed. Basal slip is characterized at is outset by the presence of numerous dipoles and elongated prismatic loops. More pronounced cold work leads to the formation of dislocation tangles and bundles which eventually give a cellular structure. Prismatic slip begins by the cross-slip of dislocations from the basal plane into the prismatic plane. A cellular structure is equally observed in heavily deformed samples. Sessile dislocations have been observed in twin boundaries; they are produced by reactions between slip dislocations and twin dislocations. Finally, the study of samples quenched from 1100 deg. C and annealed at 200 deg. C has shown that the observed loops lie in prismatic planes and have a Burgers vector b 1/3. (authors)

  2. New membranes obtained by grafted irradiated PVDF foils

    Energy Technology Data Exchange (ETDEWEB)

    Mazzei, R. [Unidad de Actividades Tecnologicas y Agropecuarias, Laboratorio de Polimeros, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Universidad Tecnologica Nacional Facultad Regional, Buenos Aires (Argentina); Garcia Bermudez, G. [Gerencia de Investigacion y Aplicaciones, Laboratorio Tandar, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Escuela de Ciencia y Tecnologia, Universidad Nacional de General San Martin, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas, Buenos Aires (Argentina); Camporotondi, D.E., E-mail: camporotondi@cae.cnea.gov.ar [Unidad de Actividades Tecnologicas y Agropecuarias, Laboratorio de Polimeros, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Arbeitman, C. [Gerencia de Investigacion y Aplicaciones, Laboratorio Tandar, Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas, Buenos Aires (Argentina); and others

    2012-09-15

    The present work describes a new method to produce membranes of poly(Acrylic-acid-Xmonomer) using the grafting procedure. PVDF foils irradiated with Ar{sup +} beam with energies between 30 and 150 keV were employed as substratum. Different combinations of monomers in water solutions were used: acrylic acid (AAc); acrylic acid-glycidyl methacrylate (AAc-GMA); acrylic acid-styrene (AAc-S), acrylic acid-N-isopropyl acrylamide (AAc-NIPAAm) and acrylic acid-N-isopropyl acrylamide-glycidyl methacrylate (AAc-NIPAAm-GMA). A large percentage of grafting results for specific values of: ion fluence and energy, AAc and sulfuric acid concentration, and different substrata PVDF polymorphous (alpha or beta). At a particular time of the grafting process, the poly(AAc-Xmonomer) membranes detach from the substratum and continue their grafting in the solution. This method is useful to produce increased replicated membranes of the irradiated original surface.

  3. Mortality in Patients with Central Retinal Vein Occlusion

    DEFF Research Database (Denmark)

    Bertelsen, Mette; Linneberg, Allan; Christoffersen, Nynne; Vorum, Henrik; Gade, Else Fredsted; Larsen, Michael

    2014-01-01

    PURPOSE: To assess mortality in patients with central retinal vein occlusion (CRVO). DESIGN: Registry-based cohort study. PARTICIPANTS AND CONTROLS: Four hundred thirty-nine photographically verified CRVO patients and a control cohort of 2195 unexposed subjects matched by age and gender and alive.......27; 95% CI, 1.03-1.56) and in women 60 to 69 years of age (SMR, 1.94; 95% CI, 1.22-3.08). CONCLUSIONS: Central retinal vein occlusion was associated with an overall increase in mortality compared with controls that was attributed statistically to cardiovascular disorders and diabetes. We recommend...

  4. Segmentally enclosed thrombolysis in percutaneous transluminal angioplasty for femoropopliteal occlusions

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Nielsen, J D; Holstein, P; Bülow, J; Jørgensen, M; Andersen, E

    1991-01-01

    Segmentally enclosed thrombolysis (SET) was performed immediately following 34 percutaneous transluminal angioplasties (PTAs) for femoropopliteal occlusions. The dilated segment was sealed off with a double balloon catheter, and recombinant tissue plasminogen activator (rt-PA) 1 mg/ml and heparin...... clinically relevant changes in plasma fibrinogen occurred. Two puncture site hemorrhages did not coincide with the coagulopathy induced by SET. One-year patency was 80%. Early rethrombosis occurred in 9% versus 41% in our previous series on standard PTA for femoropopliteal occlusions (p less than 0...

  5. Occlusion of the cystic duct by electrocoagulation: A radiologic technique

    International Nuclear Information System (INIS)

    Chemical dissolution and extracorporeal shock wave lithotripsy are promising new methods for the treatment of cholelithiasis without cholecystectomy. Nonsurgical defunctionalization of the gallbladder is now required to prevent recurrent stone formation. The authors consider cystic duct occlusion to be the first step. Ten domestic pigs underwent transcatheter electrocoagulation of the cystic duct via a cholecystostomy under fluoroscopic control. Stricture formation was followed by complete cystic duct occlusion in all ten cases. After a follow-up period ranging from 2 to 17 weeks (mean, 13 weeks), the animals were killed. Histologic studies demonstrated that complete obliteration of the cystic duct lumen was due to fibrous scar formation

  6. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention.

    Science.gov (United States)

    Kwon, Chang-Il; Lehman, Glen A

    2016-03-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422

  7. Scintigraphic patterns of veno-occlusive disease in liver transplantation.

    Science.gov (United States)

    Bernstine, Hanna; Mor, Eytan; Ben Ari, Ziv; Belinki, Alexander; Hardoff, Ruth

    2004-05-01

    Venous vascular complications in liver transplant recipients are rare. Diagnosis is usually based on clinical criteria and typical findings on liver biopsy. The scintigraphic patterns of posttransplant liver veno-occlusive disease are described, and the value of follow-up studies is suggested. The authors present 2 patients who developed posttransplantation hepatic veno-occlusive disease. The first patient had a severe form of the disease and a fatal outcome. The second patient had a mild to moderate form of this disorder with complete resolution following treatment. PMID:15069326

  8. Measuring Palatal Height in Normal Occlusion and Malocclusions

    OpenAIRE

    M. Zarringhalam

    2004-01-01

    Statement of Problem: Due to the appearance of palatal height difference in orthodontic patients we decided to carry out this study.Purpose: The purpose of this research was to determine palatal height in persons with normal occlusion and different malocclusions (class I, II Div I and III) and comp aring them with each other.Materials and Methods : In this cross sectional research, 240 subjects were selected. Sixty cases (30 girls and 30 boys) with normal occlusion within 16-18 years old were...

  9. Characteristics, Detection Methods and Treatment of Questionable Occlusal Carious Lesions

    DEFF Research Database (Denmark)

    Makhija, S.K.; Gilbert, G.H.; Funkhouser, E.;

    2014-01-01

    Questionable occlusal carious lesions (QOC) can be defined as an occlusal tooth surface with no cavitation and no radiographic radiolucencies, but caries is suspected due to roughness, surface opacities or staining. An earlier analysis of data from this study indicates 1/3 of patients have a QOC...... consenting patients presented with a QOC, information was recorded about the patient, tooth, lesion and treatments. A total of 2,603 QOC from 1,732 patients were analyzed. The lesions were usually associated with a fissure, on molars, and varied from yellow to black in color. Half presented with a chalky...

  10. Simple production method for making 3 μg/cm2 cracked slacked carbon accelerator stripper foils

    International Nuclear Information System (INIS)

    A simple method for making thin 3 μg/cm2 carbon stripper foils for heavy ion bombardment and accelerator radiochronology is described along with a simple method for stripper foil thickness determination

  11. The foil equilibration method for carbon in sodium

    International Nuclear Information System (INIS)

    Among the non-metallic impurities in sodium, carbon plays an important role since at high temperatures the structural materials exposed to sodium are subject to carburization and decarburization depending on the carbon activity of the sodium. Carburization of austenitic stainless steels leads to reduction in ductility and fatigue properties whereas decarburization results in a decrease in the high temperature creep strength. A knowledge of the carbon activities in sodium will help understanding of the carbon transfer phenomena in operating sodium systems of the fast reactors, and also carbon diffusion, microstructural stability and mechanical behaviour of materials under different service conditions. An understanding of the carbon behaviour in sodium becomes difficult in view of the complexities of the different species present as elemental carbon, carbide, acetylide, carbonate, and cyanide. Carbon estimation techniques for sodium presently in use are: chemical analytical methods, on-line carbon monitors, and oil equilibration method. Various chemical methods have been developed for the estimation of different species like acetylide, cyanide, carbonate, elemental carbon, and total carbon in sodium. All these methods are time consuming and subject to various errors. The on-line monitors developed for carbon in sodium are able to give continuous indication of carbon activities and have higher sensitivity than the chemical methods. A still more simple method for the determination of carbon activities is by the foil equilibration first published by Natesan et al. Because of its simplicity like the vanadium wire equilibration for oxygen it is being used widely for the estimation of carbon activities in sodium systems. Carbon concentrations in operating sodium systems estimated by this procedure by applying solubility relation to carbon activities have yielded very low values of carbon, lower than the sensitivity limits of the chemical estimation methods. Foil

  12. Transmission and Reflection of Neutrons Using Foil Activation Technique

    International Nuclear Information System (INIS)

    A new neutron irradiation facility has been designed, constructed .and located at the Experimental Nuclear Physics Department, NRC, AEA, cairo. The neutrons were obtained from CNIF2 (Second Cairo Neutron Irradiation Facility) that is based on one 241 Am-Be(α, n) isotopic neutron source with a present activity of about 175 GBq results in a neutron yield of about 1.04 x107 n/s. The geometrical arrangements of the facility consider the safety and protection rules aspects. MCNP5 code is used to estimate radiation doses and neutron fluxes. This new irradiation facility provides fast and epithermal neutrons that can be used in basic research and industrial applications. The aim of the present work is to study the characteristics of this new irradiation facility and to develop methods able to use fast and epithermal neutron in some different applications. Experimental measurements for the transmission and reflection of neutrons were carried out via a number of hydrogenous materials using the activation foil technique. A comparison of the experimental results with that calculated by using Monte Carlo simulation method is presented Using the neutron transmission technique in combination with foil activation method, our arrangement is used to measure the total neutron microscopic cross-sections for some compounds. The facility is calibrated and suitable to estimate the hydrogen content H (wt %) and the weight ratios C/H in hydrocarbon materials and was used to measure these ratios for some Egyptian crude oil samples. A brief overview of the neutron activation analysis methods for elemental concentrations in bulk samples in natural conditions is presented.

  13. Sinus bradycardia as a predictor of right coronary artery occlusion in patients with inferior myocardial infarction.

    Science.gov (United States)

    Serrano, C V; Bortolotto, L A; César, L A; Solimene, M C; Mansur, A P; Nicolau, J C; Ramires, J A

    1999-01-01

    Differentiation of right coronary artery (RCA) from left circumflex artery (LCxA) occlusion may be difficult since both can present an electrocardiographic pattern of inferior myocardial infarction (IMI). We studied 133 patients with IMI, 92 patients with RCA occlusion and 41 patients with LCxA occlusion. Risk factors such as previous MI, arterial hypertension, diabetes, smoking, and dislipemia, were similar for RCA and LCxA occlusions. Patients with RCA occlusion had a higher incidence of isolated IMI than patients with LCxA occlusion, 50% vs. 17%, respectively (P<0.001). Arterial hypotension was more prevalent (P<0.05) among patients with RCA (18%) rather than those with LCxA occlusion (2%). RCA occlusion presented an association with sinus bradycardia, an association not observed with LCxA occlusion (15% vs. 0%, respectively; P<0.01). Total atrioventricular block was only present among patients with RCA (18%). Proximal occlusions of the RCA presented lower heart rates (sinus bradycardia) than medial and distal occlusions (13% vs. 1% and 1%, respectively; P<0.0001 and P<0.001). Therefore, regarding patients with IMI: (1) sinus bradycardia is more frequent when the infarct-related artery is the RCA; (2) proximal occlusions of the right coronary predispose low heart rates; and (3) occlusion of the LCxA rarely induces sinus bradycardia. PMID:10077404

  14. Maintenance of radio-activated stripper foils in the 3 GeV RCS of J-PARC

    International Nuclear Information System (INIS)

    In the 3 GeV rapid cycling synchrotron (RCS) of the Japan proton accelerator research complex, we adopted the multi-turn charge exchange injection scheme using the stripper foils. After the fine beam tuning in the RCS, most of the beam losses occur at the foil only. However, the high residual doses were detected around the stripper foil, which cannot be explained by the direct scattering of the injected H- and circulating proton beams with the stripper foil. From the measurements and simulations, it is identified that secondary particles produced in the nuclear reactions with the foil had caused the high residual activity around there. The radio-activation of the foil itself and the high residual dose around the foil are intrinsic problems for all high power beam accelerators with stripping foil. A safe and efficient maintenance in the high radiation and narrow space in these accelerators is important. The foil maintenance under such an environment is required to keep staff radiation exposure as low as possible to reduce the risk of radioactive foil breakup or dispersion and to retrieve the foil without breaking for its analysis. We achieved a safe and efficient maintenance method to retrieve the radioactivated stripper foils. (author)

  15. Isolated cilioretinal artery occlusion as an initial manifestation of polycythemia vera

    OpenAIRE

    Elasri Fouad; Souhail H; Reda K; Iferkhass S; Idrissi A; Naoumi A; Oubaaz A

    2010-01-01

    Isolated cilioretinal artery occlusion is a rarely reported initial manifestation of polycythemia vera. In this study, we reported a case of a 65-year-old man with polycythemia vera with cilioretinal artery occlusion as an initial manifestation.

  16. Comparison of efficacy in crossing femoropopliteal artery occlusions with movable core and hydrophilic guidewires

    DEFF Research Database (Denmark)

    Tønnesen, K H; Bülow, J; Holstein, P;

    1994-01-01

    Compare the recanalization rate of femoropopliteal occlusions between movable core wire guide (MG) and hydrophilic guidewire (HG).......Compare the recanalization rate of femoropopliteal occlusions between movable core wire guide (MG) and hydrophilic guidewire (HG)....

  17. Soft versus hard occlusal splint therapy in the management of temporomandibular disorders (TMDs

    Directory of Open Access Journals (Sweden)

    Sameh A Seifeldin

    2015-10-01

    Conclusions: Both forms of occlusal splints (soft and hard improved TMJ symptoms in patients with MPD or ID of the TMJ. However, the soft occlusal splints exhibited superior results after 4 months of use.

  18. Comparison of radiofrequency-ablation lesion size with occlusion of renal vessels in rabbit kidneys: occlusion of renal artery, vein, and both vessels

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyuck Jae; Kim, In One [National Cancer Center, Seoul (Korea, Republic of); Lee, Jeong Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)] (and others)

    2007-09-15

    The purpose of this study was to compare the in-vivo efficiency of vascular occlusion on radiofrequency ablation (RFA) lesion size in a rabbit kidney model. RFA lesions were created in a single kidney in 20 rabbits using an internally cooled electrode. Twenty ablation zones (1 per kidney) were created using 4 different regimens: RFA without vascular occlusion (n = 5), RFA with renal artery occlusion (n = 5), RFA with renal vein occlusion (n 5), RFA with renal artery and vein occlusion (n = 5). Seven days later, the rabbits were sacrificed and the lesions were excised. These groups were then compared with respect to the dimensions of the ablation zones and the changes in impedance and current during RFA. The maximum ablation zone width was the greatest in the renal artery and vein occlusion group (21.0 {+-} 1.4 mm), followed by the renal artery occlusion group (17.8 {+-} 1.0 mm), the renal vein occlusion group (17.4 {+-} 1.1 mm), and the nonocclusion group (7.8 {+-} 2.4 mm) ({rho} < 0.05). No significant differences were observed for impedances and currents between the 4 groups. Vascular occlusion combined with RFA effectively increased ablation zone dimensions compared with RFA alone, and the best effect was accomplished by combined renal artery and vein occlusion.

  19. Young Infants' Perception of Unity and Form in Occlusion Displays.

    Science.gov (United States)

    Johnson, Scott P.; Bremner, J. Gavin; Slater, Alan M.; Mason, Uschi C.; Foster, Kirsty

    2002-01-01

    A recognition-based paradigm was used to investigate possibility that past research failed to sensitively assess infants' perception of the unity of misaligned edges in partial occlusion displays. Results suggested that habituation designs tapping recognition processes may be particularly efficacious in revealing infants' perceptual organization.…

  20. Sex Differences during Visual Scanning of Occlusion Events in Infants

    Science.gov (United States)

    Wilcox, Teresa; Alexander, Gerianne M.; Wheeler, Lesley; Norvell, Jennifer M.

    2012-01-01

    A growing number of sex differences in infancy have been reported. One task on which they have been observed reliably is the event-mapping task. In event mapping, infants view an occlusion event involving 1 or 2 objects, the occluder is removed, and then infants see 1 object. Typically, boys are more likely than girls to detect an inconsistency…

  1. Learning about Occlusion: Initial Assumptions and Rapid Adjustments

    Science.gov (United States)

    Kochukhova, Olga; Gredeback, Gustaf

    2007-01-01

    We examined 6-month-olds' abilities to represent occluded objects, using a corneal-reflection eye-tracking technique. Experiment 1 compared infants' ability to extrapolate the current pre-occlusion trajectory with their ability to base predictions on recent experiences of novel object motions. In the first condition infants performed at asymptote…

  2. Hidden in Plain Sight: Occlusion in Pedagogical Genres

    Science.gov (United States)

    Neaderhiser, Stephen E.

    2016-01-01

    Occluded genres in academia work "behind the scenes" to support and develop an academic's professional identity. However, while significant attention has been paid to occluded genres that support an academic's identity as a researcher, very little scholarship examines how occlusion operates in genres of pedagogy, such as the syllabus,…

  3. Laser atherectomy in the treatment of peripheral arterial occlusive disease

    Czech Academy of Sciences Publication Activity Database

    Randula, A.; Thieme, M.; Schwenk, M.; Veverková, L.; Číp, Ondřej; Buchta, Zdeněk

    Elsevier. Vol. 9, Suppl. 1 (2012), S8. ISSN 1572-1000. [Photodiagnostics and Photodynamics Therapy. International Congress. 24.08.2012-29.08.2012, Helsinki] R&D Projects: GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : excimer pulse laser * peripheral arterial occlusive disease Subject RIV: BH - Optics, Masers, Lasers

  4. Sickle cell vaso-occlusion in an animal model

    International Nuclear Information System (INIS)

    Sickle cell disease is clinically characterized with vaso-occlusive painful crisis which is pleomorphic in terms of frequency of occurrence. The intracellular polymerization of deoxygenated hemoglobin S increases the internal viscosity of the sickle cells exponentially, concurrent with binding of hemoglobin S to the membrane and discocyte-drepanocyte transformation. As a result, the red cells in sickle cell disease are heterogenous with cells of varying density and mean corpuscular hemoglobin concentration which alter the rheological features of the blood in the microcirculation. The cellular, physiological, biochemical and rheological factors that contribute to the vaso-occlusive events are not completely understood. Nonetheless, recent clinical studies have demonstrated that a certain fraction of the dense cells disappear during sickle cell painful crisis. In an attempt to elucidate some of the cellular and rheological factors involved in the initiation of vaso-occlusion, the authors have employed intravital videomicroscopy and radionuclide imaging of indium-III labeled sickle cells to determine the dynamics and sites of vaso-occlusion using the rat exchanged-transfused with sickle (HbSS) erythrocytes as a model

  5. Endovascular treatment for right subclavian artery occlusion: techniques and results

    International Nuclear Information System (INIS)

    Objective: To evaluate the technique and result of endovascular treatment for right subclavian artery stenosis or occlusion. Methods: Seventeen patients [13 males, 4 females; (56 ± 11) years old] with right subclavian artery stenosis or occlusion were treated with endovascular surgery which included recanalization, balloon angioplasty and stenting via femoral or brachial artery route. Cerebral protection devices were used in 6 cases to avoid cerebral embolism. Results: Sixteen of the seventeen patients acquired successful recanalization in 8 cases with subclavian artery stenosis (100% technical success rate) and in other 8 cases with subclavian artery occlusion (88.9% technical success rate). Five cases were treated with balloon angioplasty, and 11 cases were treated with balloon angioplasty combined with stenting. Good patency was seen in the 16 cases immediately after the procedure. The cerebral protection devices prevented all the cases from cerebral embolism and were retrieved successfully. Sixteen cases were followed up from 1 to 66 months [mean (24 ± 18) months]. Restenosis was found in one case 10 months later and was successfully treated with re-PTA. One case with aortoarteritis died of cerebral infarction 18 months later. No symptom recurrence was found in other cases and ultrasound or CTA of followup showed excellent patency. Conclusions: Balloon angioplasty and stenting are safe and effective for the treatment of right subclavian artery occlusion. (authors)

  6. Gender influence on occlusal characteristics in the primary dentition

    Directory of Open Access Journals (Sweden)

    Nisha Rani Yadav

    2014-01-01

    Full Text Available Objectives: The objective of this study was to assess and discuss the influence of gender on occlusal characteristics of primary dentition. Materials and Methods: In this study, cluster randomized sampling was done to select 4-6-year-old children from Government primary schools of Farukh Nagar block, Gurgaon, Haryana, India. Children were evaluated clinically for occlusal characteristics of primary dentition such as molar relation, Canine relation, overjet, overbite, openbite, scissors bite, and crossbite. Chi-square test was used to compare the occlusal characteristics of both genders. Results: Flush terminal plane, Class I Canine relation and both primate as well as developmental spaces were found to be prevalent in the study population, in percentages of 62.4%, 67.2%, and 37.6%, respectively. It was observed that females had more spacing, distal step molar relation and increased overjet as compared to males. Males had more Class II Canine relation, crowding, openbite, overbite, and incompetent lips as compared to females. Significant differences were found between males and females w.r.t various occlusal characteristics. Conclusion: Most of the children had gender influence on malocclusion, which indicates the need for early interception or correction of malocclusion traits based on the gender of the child.

  7. Non-occlusive mesenteric ischemia: etiology, diagnosis, and interventional therapy

    Energy Technology Data Exchange (ETDEWEB)

    Trompeter, Markus; Brazda, Thurid; Remy, Christopher T.; Reimer, Peter [Department of Radiology, Staedtisches Klinikum Karlsruhe (Germany); Vestring, Thomas [Department of Radiology, Diakonie-Krankenhaus Rotenburg/Wuemme, Goettingen (Germany)

    2002-05-01

    Non-occlusive mesenteric ischemia (NOMI) compromises all forms of mesenteric ischemia with patent mesenteric arteries. It generally affects patients over 50 years of age suffering from myocardial infarction, congestive heart failure, aortic insufficiency, renal or hepatic disease and patients following cardiac surgery. Non-occlusive disease accounts for 20-30% of all cases of acute mesenteric ischemia with a mortality rate of the order of 50%. Acute abdominal pain may be the only early presenting symptom of mesenteric ischemia. Non-invasive imaging modalities, such as CT, MRI, and ultrasound, are able to evaluate the aorta and the origins of splanchnic arteries. Despite the technical evolution of those methods, selective angiography of mesenteric arteries is still the gold standard in diagnosing peripheral splanchnic vessel disease. In early non-occlusive mesenteric ischemia, as opposed to occlusive disease, there is no surgical therapy. It is known that mesenteric vasospasm persists even after correction of the precipitating event. Vasospasm frequently responds to direct intra-arterial vasodilator therapy, which is the only treatment that has been shown to be effective. (orig.)

  8. Non-occlusive mesenteric ischemia: etiology, diagnosis, and interventional therapy

    International Nuclear Information System (INIS)

    Non-occlusive mesenteric ischemia (NOMI) compromises all forms of mesenteric ischemia with patent mesenteric arteries. It generally affects patients over 50 years of age suffering from myocardial infarction, congestive heart failure, aortic insufficiency, renal or hepatic disease and patients following cardiac surgery. Non-occlusive disease accounts for 20-30% of all cases of acute mesenteric ischemia with a mortality rate of the order of 50%. Acute abdominal pain may be the only early presenting symptom of mesenteric ischemia. Non-invasive imaging modalities, such as CT, MRI, and ultrasound, are able to evaluate the aorta and the origins of splanchnic arteries. Despite the technical evolution of those methods, selective angiography of mesenteric arteries is still the gold standard in diagnosing peripheral splanchnic vessel disease. In early non-occlusive mesenteric ischemia, as opposed to occlusive disease, there is no surgical therapy. It is known that mesenteric vasospasm persists even after correction of the precipitating event. Vasospasm frequently responds to direct intra-arterial vasodilator therapy, which is the only treatment that has been shown to be effective. (orig.)

  9. Occlusal Caries Management: Preferences among Dentists in Norway.

    Science.gov (United States)

    Kopperud, Simen E; Tveit, Anne B; Opdam, Niek J M; Espelid, Ivar

    2016-01-01

    The aim was to measure variations in the threshold for operative treatment of occlusal caries in permanent teeth and the use of dental materials, compared with results from a similar study conducted in Norway in 1995. In 2009, a precoded questionnaire was sent electronically to 3,654 dentists with E-mail addresses in the member register of the Norwegian Dental Association. The questions were related to caries, treatment strategies and choice of dental materials. Replies were obtained from 61.3% respondents after two reminders. Restorative treatment of occlusal lesions confined to enamel was proposed by 12% of the dentists, compared with 18% in 1995 (p risk of restoring occlusal enamel lesions operatively. The authors conclude that especially young dentists appear to be more reluctant to remove tooth substance in 2009 compared with 1995. Composite is the dominating material of choice in 2009 and seems to have substituted the use of most other filling materials in occlusal restorations in permanent teeth. PMID:26839953

  10. Central retinal artery occlusion: an unusual complication of snakebite

    Directory of Open Access Journals (Sweden)

    A. Bhalla

    2004-01-01

    Full Text Available Snakebites are endemic in some parts of India, being associated with a number of complications. Ocular disturbances are rare, except for injury to the cornea or conjunctiva when the eye is directly exposed to the venom. In this work, we present a case of central retinal artery occlusion caused by snakebite.

  11. Head movements in the occlusal phase of mastication.

    Science.gov (United States)

    Matsubara, Nozomu; Hisano, Masataka; Minakuchi, Shunsuke; Soma, Kunimichi

    2002-03-01

    It has been recognized that mandibular movements evoke head movements during jaw tapping. However there have been only a few studies that investigated the aspects of head movements during mastication. The objective of this study was to demonstrate the hypothesis that the head moves actively in mastication in order to achieve effective destruction of a food bolus. Head and mandibular movements during gum, gummi candies and kelp chewing among nine adult volunteers have been recorded as time series data with a three-dimensional motion capture system and the vertical components of the movements have been analyzed. To focus on occlusal phase of mastication, the following parameters have been examined: time lag of the head movements at the beginning of occlusal phase, perpendicular velocity of the head at the beginning of the phase of occlusion, and average velocity of the head during occlusal phase. The results showed that the head moved downward in mastication and the velocity of the head movements increased in the order of gum, gummi candies and kelp chewing. There is a possibility that the elasticity of a food bolus affects the activity of head movements, and the kinetic energy was increased to achieve effective destruction of a food bolus. PMID:12160225

  12. Left atrial appendage occlusion for stroke prevention in atrial fibrillation

    DEFF Research Database (Denmark)

    Tzikas, Apostolos; Shakir, Samera; Gafoor, Sameer;

    2015-01-01

    Aims: To investigate the safety, feasibility, and efficacy of left atrial appendage occlusion (LAAO) with the AMPLATZER Cardiac Plug (ACP) for stroke prevention in patients with atrial fibrillation (AF). Methods and results: Data from consecutive patients treated in 22 centres were collected. A...

  13. Carotid arteries in central retinal vessel occlusion as assessed by Doppler ultrasound.

    OpenAIRE

    Peternel, P; Keber, D; Videcnik, V

    1989-01-01

    Doppler ultrasound was used to detect possible flow changes in the carotid arteries of patients with central retinal artery and vein occlusion. Twenty-three patients with central retinal artery occlusion (mean age 56, SD 11, years) were examined 4 to 48 months after the development of the occlusion and compared with age and sex matched control subjects with no history of any disease known to be associated with pathological changes in carotid vessels. Significant stenosis or occlusion of one o...

  14. Changes in Coronary Perfusion after Occlusion of Coronary Arteries in Kawasaki Disease

    OpenAIRE

    Kwak, Ji Hee; Song, Jinyoung; Kang, I-Seok; Huh, June; Lee, Heung-Jae

    2014-01-01

    Purpose Myocardial infarction in children with total occlusion of a coronary artery after Kawasaki disease is rare due to multiple collateral vessels. We aimed to investigate the changes in coronary perfusion associated with coronary artery occlusion after Kawasaki disease. Materials and Methods Eleven patients with coronary artery occlusion after Kawasaki disease were investigated. Serial coronary angiographies after total occlusion of a coronary artery were reviewed and the changes were des...

  15. Thrombotic occlusion of the ostial left main coronary artery in a patient with acute coronary syndrome

    OpenAIRE

    Tatli, E.

    2009-01-01

    Ostial left main coronary artery (LMCA) occlusion is rarely seen in patients with acute coronary syndrome. Acute coronary syndrome resulting from an LMCA occlusion is associated with a significant morbidity and mortality rate, if it is managed with fibrinolysis. Electrocardiography can predict LMCA occlusion in patients with acute coronary syndrome. We report a 52-year-old male who presented with acute coronary syndrome and ostial LMCA occlusion. (Neth Heart J 2009;17:295-6.19789699)

  16. Severe Gingival Recession Caused by Traumatic Occlusion and Mucogingival Stress: A Case Report

    OpenAIRE

    Ustun, Kemal; Sari, Zafer; ORUCOGLU, HASAN; Duran, Ismet; Hakki, Sema S.

    2008-01-01

    Gingival recession is displacement of the soft tissue margin apically leading to root surface exposure. Tooth malpositions, high muscle attachment, frenal pull have been associated with gingival tissue recession. Occlusal trauma is defined as injury resulting in tissue changes within the attachment apparatus as a result of occlusal forces. Trauma from occlusion may cause a shift in tooth position and the direction of the movement depends on the occlusal force. We present the clinical and radi...

  17. Ultrasonic-assisted ac etching of aluminum foils for electrolytic capacitor electrodes with enhanced capacitance

    International Nuclear Information System (INIS)

    ac etching of high-purity aluminum foils in hybrid acids including hydrochloric acid, sulphuric acid and oxalic acid was investigated and the effects of ultrasonic-assisted stirring on the performances of the etched foils were investigated in this work. Scanning electron microscopy (SEM) was used for observation of the etched foils. Compared with the classically used mechanical stirring (magnetic stirring), the assistance of ultrasonic increased the performance of the etched foil. With 20 V forming voltage, the static capacitance and bending strength of the foils etched with ultrasonic stirring reached 76.5 μF cm-2 and 98 times compared with 71.2 μF cm-2 and 85 times respectively for the foils fabricated with magnetic stirring using 100 μm aluminum foils. The performance enhancement with the assistance of ultrasonic is probably due to the cavitation effects which are beneficial for the remove of protective layer and the dispersion effects which reduce concentration polarization in the bulk etchant solutions.

  18. Gas Electron Multiplier foil holes: a study of mechanical and deformation effects

    Science.gov (United States)

    Benussi, L.; Bianco, S.; Saviano, G.; Muhammad, S.; Piccolo, D.; Suhaj, A.; Sharma, A.; Caponero, M.; Passamonti, L.; Pierluigi, D.; Russo, A.; Lalli, A.; Valente, M.; Ferrini, M.; Langeslag, S. A. E.; Sgobba, S.; Aviles, I.; Magnani, A.; Vai, I.

    2016-08-01

    The GEM detectors will be installed at the Compact Muon Solenoid (CMS) experiment during Long Shutdown II of the LHC in 2018. The GEM foil is a basic part of the detector which consists of a composite material, i.e. polyimide coated with copper and perforated with a high density of micro holes. In this paper the results of the GEM foil material characterization are reported, and a campaign of tensile and holes deformation tests is performed. During the tests, the complex radiation environment at CMS is taken into account and samples are prepared accordingly to see the impacts of the radiation on the GEM foil, i.e. non-irradiated samples are used as the reference and compared with neutrons- and gamma- irradiated. These studies provide the information necessary to optimize the stress level without damaging the foil and holes during the detector assembly in which the GEM foils stack is stretched simultaneously to maintain the uniform gap among the foils in order to get the designed performance of the detector. Finally, an estimate of the Young's modulus of the GEM foil is provided by using the tensile test data.

  19. DuraFoil{sup TM} ICR-a new material for catalytic converter substrates

    Energy Technology Data Exchange (ETDEWEB)

    Sukonnik, I.M.; Chang, S.; Jha, B. [Texas Instruments, Inc., Attleboro, MA (United States)

    1997-12-31

    A new type of FeCrAl material for catalytic converter substrate applications, DuraFoil{sup TM} ICR, has been developed by solid state bonding of strip layers of steel and aluminum. Such clad material is further rolled to intermediate gauge and then subjected to a thermal in situ reaction to form a solid solution material. Such monolithic material is subsequently thermomechanically processed to foil gauges. The combination of roll bonding followed by thermo-mechanical processing to produce FeCrAl foil for metallic catalytic converter substrate offers many metallurgical and economic advantages over conventional ingot metallurgy practice. The fact that thermal diffusion was performed at the intermediate gauge prior to reaching the final foil thickness gives material properties for use in the wider design range of catalytic converters. In its simplest form, the requirements for a catalytic converter substrate (foil material) are dictated by four major factors: oxidation resistance; shape stability; formability (applicable ductility); and compatibility with typical substrate processing technologies such as brazing and washcoating. To this end, the microstructures, mechanical properties, chemical homogeneity, surface chemistry and morphology of two DuraFoil{sup TM} new grades foil materials, i.e., ICR-H (hard) and ICR-F (soft), were characterized. This study has shown those superior properties, desirable formability can be achieved from diffusion-made material. (orig.)

  20. Evaluation of chromic acid anodized aluminum foil coated composite tubes for the Space Station truss structure

    Science.gov (United States)

    Dursch, Harry W.; Slemp, Wayne S.

    1988-01-01

    This paper describes the development and evaluation of chromic acid anodized (CAA) Al foil as a protective and thermal control coating for graphite/epoxy tubes designed for the Space Station truss structure. Special consideration is given to the development of solar-absorptance and thermal-emittance properties required of Al foil, the development of CAA parameters necessary to achieve these optical properties, and the atomic oxygen and UV testing of CAA Al foil. Results showed that 0.003-in CAA Al foil cocured or secondary bonded to graphite/epoxy tubes with thin epoxy film adhesive retains excellent bond strength and provides a superior protective and thermal control coating to the LEO environment. Processes were developed for CAA Al foils long enough to continuously wrap the 23-ft-long diagonal struts of the Space Station truss structure. Specifications are presented for the processes of chromic acid anodizing of Al foil and for the bonding of anodized Al foil to graphite/epoxy tubes.

  1. Carbon/graphene foils: a critical subsystem for plasma instruments in space

    Science.gov (United States)

    Allegrini, F.; Ebert, R. W.; Fuselier, S. A.; Bedworth, P.; Sinton, S.

    2015-12-01

    Thin carbon foils play a critical role in the time-of-flight (TOF) and charge conversion subsystems used in many of the plasma sensors developed for space. These instruments take advantage of properties of the particle-foil interaction: charge conversion of neutral atoms and/or secondary electron emission. This interaction also creates several adverse effects for the projectile exiting the foil, such as angular scattering and energy straggling, that usually act to reduce the sensitivity and overall performance of an instrument. The magnitude of these effects varies with the incident angle, energy, and mass of the incoming projectile and the foil thickness. The thinnest foils flown typically have a nominal thickness (as specified by the manufacturer) of ~0.5 - 1 µg cm-2. In this presentation, we will summarize several studies that have quantified the properties of ions exiting the thin carbon foil and discuss recent work on graphene foils, a promising new technology that may be capable of mitigating the undesirable effects associated with these interactions.

  2. Improvement of the accuracy of the imaging bolometer foil laser calibration

    International Nuclear Information System (INIS)

    An imaging bolometer with a single graphite-coated metal foil is a diagnostic tool for diagnosing plasma radiation from magnetic fusion plasmas. We could obtain the local foil properties (the thermal diffusivity, κ, and the product of the thermal conductivity, k, and the thickness, tf) of the metal imaging bolometer foil by analyzing the calibration data. For improving the IRVB a Tantalum (Ta) foil is offered due to strength, low neutron cross-section, and high sensitivity, however there is a large discrepancy between the value of the foil thickness from the experimental value and the nominal value. For calibrating of the foil the He-Ne laser beam is focused on 63 various locations which are determined by using the marks on the frame. The parameters of the foil are determined by comparing the measured thermal radiation data from an IR camera (FLIR/SC500) (60 Hz, 320x240 pixels, 7.5-13 μm) with the corresponding results of a finite element model. (author)

  3. 40 CFR 180.1148 - Occlusion Bodies of the Granulosis Virus of Cydia pomenella; tolerance exemption.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Occlusion Bodies of the Granulosis... RESIDUES IN FOOD Exemptions From Tolerances § 180.1148 Occlusion Bodies of the Granulosis Virus of Cydia... of the microbial pest control agent Occlusion Bodies of the Granulosis Virus of Cydia...

  4. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close...

  5. Genome sequence of an Adoxophyes orana granulovirus (AdorGV) occlusion body morphology mutant

    Science.gov (United States)

    - Genome sequence of an Adoxophyes orana granulovirus (AdorGV) occlusion body morphology mutant Baculoviruses package virus particles in a crystalline matrix of viral protein to form occlusion bodies. Occlusion bodies are used in biological control because the crystalline matrix protects the viral ...

  6. Digital Evaluation of Functional Occlusion Parameters and their Association with Temporomandibular Disorders

    OpenAIRE

    Haralur, Satheesh B.

    2013-01-01

    Context: Dental researchers are contradictory in their opinion on the role of occlusion in TMD. Occlusal evaluation of both conventional and digital methods in TMD patients will provide the accurate information about the factors accountable for occlusal instability. Identifying the factors responsible will facilitate precise diagnosis and treatment for TMD.

  7. Endovascular revascularization for non-acute basilar artery occlusion

    International Nuclear Information System (INIS)

    Objective: To evaluate the technical feasibility, safety and mid-term effect of endovascular revascularization for non-acute intracranial basilar artery occlusion. Methods: During the period from Feb. 2010 to Apr. 2012, endovascular revascularization was carried out in 12 patients with non- acute basilar artery occlusion, and the onset of the occlusion was beyond 24 hours. The clinical data were retrospectively analyzed. Complications and recurrent events occurring during the follow-up period were recorded. The modified Rankin scale (mRS) scores were determined, and the preoperative scores were compared with postoperative ones. Results: Successful revascularization was obtained in all the 12 patients except one. After the procedure, the clinical condition was improved in 6, remain stable in 4, and became worse in 2 patients. The preoperative median mRS score was 5 (R, 3-5), it decreased to 4.5 (R, 1-5) on discharge. The difference was statistically significant (P=0.020, Z=2.333). Two patients developed procedural complications, including dissection (n=1) and acute re-occlusion (n=1) after operation. During a median follow-up time of 17.5 months, death occurred in 3 cases, recurrent stroke in 2 cases and transient ischemic attack in one case. The latest median mRS scores were 3 (IR, 0-6). Follow-up check with imaging examination was employed in 8 patients during a median follow -up time of 12 months, and symptomatic restenosis occurred in two cases. Conclusion: Endovascular revascularization for the non-acute intracranial vertebrobasilar artery occlusion beyond 24 hours is technically feasible, it can improve the mid-term prognosis. However, further research is needed to confirm its efficacy. (authors)

  8. Fundus artery occlusion caused by cosmetic facial injections

    Institute of Scientific and Technical Information of China (English)

    Chen Yanyun; Wang Wenying; Li Jipeng; Yu Yajie; Li Lin; Lu Ning

    2014-01-01

    Background With the increasing popularity of cosmetic facial filler injections in recent years,more and more associated complications have been reported.However,the causative surgical procedures and preventative measures have not been studied well up to now.The aim of this stady was to investigate the clinical characteristics and visual prognosis of fundus artery occlusion resulting from cosmetic facial filler injections.Methods Thirteen consecutive patients with fundus artery occlusion caused by facial filler injections were included.Main outcome measures were filler materials,injection sites,best-corrected visual acuity (BCVA),fundus fluorescein angiography,and associated ocular and systemic manifestations.Results Eleven patients had ophthalmic artery occlusion (OAO) and one patient each had central retinal artery occlusion (CRAO) and anterior ischemic optic neuropathy (AION).Injected materials included autologous fat (seven cases),hyaluronic acid (five cases),and bone collagen (one case).Injection sites were the frontal area (five cases),periocular area (two cases),temple area (two cases),and nose area and nasal area (4 cases).Injected autologous fat was associated with worse final BCVA than hyaluronic acid.The BCVA of seven patients with autologous fat injection in frontal area and temple area was no light perception.Most of the patients with OAO had ocular pain,headache,ptosis,ophthalmoplegia,and no improvement in final BCVA.Conclusions Cosmetic facial injections can cause fundus artery occlusion.Autologous fat injection tends to be associated with painful blindness,ptosis,ophthalmoplegia,and poor visual outcomes.The prognosis is much worse with autologous fat injection than hyaluronic acid injection.

  9. Life cycle Analysis of Aluminum Foil Packaging Material.

    Science.gov (United States)

    El Sebaie, Olfat; Ahmed, Manal; Hussein, Ahmed; El Sharkawy, Fahmay; Samy, Manal

    2006-01-01

    A fundamental tent of life cycle analysis (LCA) is that every material product must become a waste. To choose the greener products, it is necessary to take into account their environmental impacts from cradle to grave. LCA is the tool used to measure environmental improvements. Aluminum (Al) is the third most common element found in the earth's crust, after oxygen and silicon. Al packaging foil was chosen as the material for the study with its life cycle perspective at Alexandria. The Al packaging produced from virgin and recycled Al was investigated through life cycle stages in these two production processes; primary and secondary. The aim of this study is to evaluate the environmental impact of aluminum packaging process by using life cycle analysis of its product from two different starting raw materials (virgin and recycled aluminum). The input and output materials, energy, water, natural gas consumptions, and solid waste uses in the foil industry had been analyzed in order to identify those with significant contribution to the total environmental impacts. From the survey done on the two life cycles, it was found that in environmental terms, the most important emissions from the primary process are the emission of CO(2) and perfluorocarbon (PFC) gases, which produce the greenhouse effect, and SO(2) as well as the emission of fluorides and polyaromatic hydrocarbons (PAH compounds), which are toxic to humans and the environment. On over all material balance, it was found that the ingot shares by 45% of the feed to the casthouse furnaces at Egyptian Copper Work (ECW), net production of the casthouse is 43.76% and the yield of rotary dross furnace (RDF) is 28.8%. The net production of the foil unit represents 35% of the total input to the unit. By comparing the two life cycles, it is obvious that, for water consumption, 93.5% is used in the primary cycle, while 6.5% is used in the secondary cycle. For electricity consumption, 99.3% is used in the primary cycle

  10. Development of Thick-foil and Fine-pitch GEMs with a Laser Etching Technique

    OpenAIRE

    Tamagawa, T.; Asami, F.; Abe, K.; Iwamoto, S.; Nakamura, S.; Hayato, A.; Iwahashi, T.; Konami, S.; Hamagaki, H.; Yamaguchi, Y. L.; Tawara, H.; Makishima, K.

    2009-01-01

    We have produced thick-foil and fine-pitch gas electron multipliers (GEMs) using a laser etching technique. To improve production yield we have employed a new material, Liquid Crystal Polymer, instead of polyimide as an insulator layer. The effective gain of the thick-foil GEM with a hole pitch of 140 um, a hole diameter of 70 um, and a thickness of 100 um reached a value of 10^4 at an applied voltage of 720 V. The measured effective gain of the thick-foil and fine-pitch GEM (80 um pitch, 40 ...

  11. Optimizing dc-resistance of a foil wounded toroidal inductor combining matlab and comsol

    DEFF Research Database (Denmark)

    Schneider, Henrik; Andersen, Thomas; Knott, Arnold;

    2013-01-01

    An optimization routine is presented to optimize the shape of a foil winding of a toroid inductor in terms of the DC resistance. MATLAB was used to define the geometry of the foil winding and COMSOL was used to import the geometry and create a 3D finite element model. The initial parameters, the...... execution and the results of the optimization routine were all managed from a graphical user interface and the feedback from COMSOL in terms of DC resistance was used to find and plot the optimal shape of the foil. The DC resistance was improvement by 31 % compared with previous work for a 10 turn toroidal...

  12. Electroplating fission-recoil barriers onto LEU-metal foils for 99Mo-production targets

    International Nuclear Information System (INIS)

    Electroplating experiments on uranium foil have been conducted in order to develop low-enriched uranium composite targets suitable for the production of 99Mo. Preparation of the foil surface prior to plating was found to play a key role in the quality of the resultant coating. A surface preparation procedure was developed that produces both zinc and nickel coatings with the desired level of coating adherence and coverage. Modifications of the existing plating processes now need investigation to improve to uniformity of the plating thickness, especially at the foil perimeter

  13. Formation and evolution of tweed structures on high-purity aluminum polycrystalline foils under cyclic tension

    International Nuclear Information System (INIS)

    Peculiarities of formation and evolution of tweed structures on the surface of high-purity aluminum polycrystalline foils under cyclic tension were studied using an atom force microscope and a white light interferometer. Tweed structures of micron and submicron sizes were found on the foils at different number of cycles. In the range of 42,000 < N < 95,000 cycles destruction of tweed patterns is observed, which leads to their disappearance from the surface of the foils. Formation of tweed structures of various scales is discussed in terms of the Grinfeld instability

  14. Suppression of instability by double ablation in tungsten doped polyvinyl alcohol foils

    International Nuclear Information System (INIS)

    In Inertial fusion Energy (IFE) research stable acceleration of fusion targets is a significant problem due to hydrodynamic instabilities. This paper presents the results of the experiments done to investigate the effects of doping 20% of Tungsten (W) (by weight) in Polyvinyl Alcohol (PVA) polymer foils for suppression of instability during laser ablative acceleration. A 20J, 1.060μm, 900ps, Nd: Glass laser system with a focusable intensity of 3 to 9.6×1013W/cm2 was used in the experiment. It is observed that the doped PVA targets yielded stable and enhanced foil acceleration as compared to the undoped PVA foils.

  15. Formation and evolution of tweed structures on high-purity aluminum polycrystalline foils under cyclic tension

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, P. V., E-mail: kpv@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Vlasov, I. V. [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); Sklyarova, E. A.; Smekalina, T. V. [National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation)

    2015-10-27

    Peculiarities of formation and evolution of tweed structures on the surface of high-purity aluminum polycrystalline foils under cyclic tension were studied using an atom force microscope and a white light interferometer. Tweed structures of micron and submicron sizes were found on the foils at different number of cycles. In the range of 42,000 < N < 95,000 cycles destruction of tweed patterns is observed, which leads to their disappearance from the surface of the foils. Formation of tweed structures of various scales is discussed in terms of the Grinfeld instability.

  16. Large white organic light-emitting diode lighting panel on metal foils

    OpenAIRE

    Guaino, Philippe; Mazeri, Fabrizo; Hofmann, Michael; Birnstock, Jan; Avril, Ludovic; Viville, Pascal; Kanaan, Hani; Lazzaroni, Roberto; Loicq, Jerôme; Rotheudt, Frank; Pans, Christian

    2011-01-01

    Large-area top-emitting PIN structure (highly p- and n- type doped transport layers for electrons and holes and an undoped emitter layer)–organic light-emitting diode (OLED) on advanced metal foils were fabricated for lighting applications. ArcelorMittal has developed a new surface treatment on metal foils, suitable for roll-to-roll production and dedicated to large-area device integration. Both monochromatic and white devices are realized on advanced metal foils. Power efficiencies at 1000 c...

  17. Shock compression response of highly reactive Ni + Al multilayered thin foils

    Science.gov (United States)

    Kelly, Sean C.; Thadhani, Naresh N.

    2016-03-01

    The shock-compression response of Ni + Al multilayered thin foils is investigated using laser-accelerated thin-foil plate-impact experiments over the pressure range of 2 to 11 GPa. The foils contain alternating Ni and Al layers (parallel but not flat) of nominally 50 nm bilayer spacing. The goal is to determine the equation of state and shock-induced reactivity of these highly reactive fully dense thin-foil materials. The laser-accelerated thin-foil impact set-up involved combined use of photon-doppler-velocimetry to monitor the acceleration and impact velocity of an aluminum flyer, and VISAR interferometry was used to monitor the back free-surface velocity of the impacted Ni + Al multilayered target. The shock-compression response of the Ni + Al target foils was determined using experimentally measured parameters and impedance matching approach, with error bars identified considering systematic and experimental errors. Meso-scale CTH shock simulations were performed using real imported microstructures of the cross-sections of the multilayered Ni + Al foils to compute the Hugoniot response (assuming no reaction) for correlation with their experimentally determined equation of state. It was observed that at particle velocities below ˜150 m/s, the experimentally determined equation of state trend matches the CTH-predicted inert response and is consistent with the observed unreacted state of the recovered Ni + Al target foils from this velocity regime. At higher particle velocities, the experimentally determined equation of state deviates from the CTH-predicted inert response. A complete and self-sustained reaction is also seen in targets recovered from experiments performed at these higher particle velocities. The deviation in the measured equation of state, to higher shock speeds and expanded volumes, combined with the observation of complete reaction in the recovered multilayered foils, confirmed via microstructure characterization, is indicative of the occurrence

  18. Full size U-10Mo monolithic fuel foil and fuel plate fabrication-technology development

    International Nuclear Information System (INIS)

    Full-size U-10Mo foils are being developed for use in high density LEU monolithic fuel plates. The application of a zirconium barrier layer to the foil is performed using a hot co-rolling process. Aluminium clad fuel plates are fabricated using Hot Isostatic Pressing (HIP) or a Friction Bonding (FB) process. An overview is provided of ongoing technology development activities, including: the co-rolling process, foil shearing/slitting and polishing, cladding bonding processes, plate forming, plate-assembly swaging, and fuel plate characterization. Characterization techniques being employed include, Ultrasonic Testing (UT), radiography, and microscopy. (author)

  19. Cervical occlusion in women with cervical insufficiency: protocol for a randomised, controlled trial with cerclage, with and without cervical occlusion

    DEFF Research Database (Denmark)

    Secher, Niels Jørgen; MaCormack, CD; Weber, Tom;

    2007-01-01

    , without the membranes being exposed to the vagina. 6. Tertiary cerclage: Short cervix, membranes exposed to the vagina. Observational study: Eligible women who refuse to be randomised will participate in an observational study. 7. Repeat/requested cervical occlusion. METHODS: The women will be randomised...

  20. Balloon Occlusion of the Contralateral Iliac Artery to Assist Recanalization of the Ipsilateral Iliac Artery in Total Aortoiliac Occlusion: A Technical Note

    OpenAIRE

    Abdel Aziz A. Jaffan

    2013-01-01

    Endovascular recanalization of chronic total aortoiliac occlusion is technically challenging. Inability to reenter the true aortic lumen, following retrograde iliac recanalization, is one of the most common causes of failure. We describe a case of a total aortoiliac occlusion where balloon occlusion of the right common iliac artery, following its recanalization from a brachial approach, was used to facilitate antegrade recanalization of the occluded contralateral left common iliac artery.

  1. Structure studies of carbon foils with the aim to improve the ability for heavy-ion stripping

    International Nuclear Information System (INIS)

    Slackened carbon stripper foils of 3 to 5 μg/cm2 produced by vacuum evaporation-condensation were graphitized by annealing at about 3300 K with a pulsed laser beam (1.06 μm). An average crystal size of 10 nm was measured by electron diffraction. The texture of the 002-plane is parallel to the surface of the foil as known from slightly annealed carbon foils. Radiation damages caused by high doses of heavy ions dramatically change the crystal structure. Electron diffraction patterns reveal newly formed graphite crystals with their 002-plane perpendicular to the texture. Compared to carbon foils of the same kind, but not graphitized, a lifetime prolongation of a factor of two was achieved for such foils tested in the terminal of the Munich MP tandem. The slope of the curve for heavy-ion transmission through carbon stripper foils varies for foils of the same kind and for different ion-beam conditions. (orig.)

  2. Development of the fabrication technology of wide uranium foils for Mo-99 irradiation target by cooling-roll casting method

    International Nuclear Information System (INIS)

    An alternative fabrication method for polycrystalline uranium foils has been investigated using a cooling-roll casting method at KAERI since 2001, in order to produce a medical isotope 99Mo, the parent nuclide of 99mTc. The fabrication method of wide uranium foils produced by a cooling-roll casting was recently developed to improve the quality of the uranium foils and the economic efficiency of the foil fabrication with modifications of the casting apparatus and adjustments of the process parameters. A continuous polycrystalline LEU foil with a thickness range of 100 to 150 μm. and a width of about 50 mm, exceeding 5m in length for a batch procedure, could be fabricated with a better quality of the uranium foil and a higher yield of the foil fabrication, through improvements of the casting apparatus and variations of the process parameters. (author)

  3. Use of STIM for morphological studies of microstructured polymer foils

    International Nuclear Information System (INIS)

    In this work, morphological characterization of microstructures produced by focused 3 MeV H+ beams and chemical etching on poly(ethylene terephthalate) foils was investigated by on- and off-axis scanning transmission ion microscopy (STIM). STIM images were obtained from different energy regions of the transmitted energy spectra. STIM performance was compared to scanning electron microscopy (SEM) used as a reference. STIM and SEM images provided similar morphological information. The deviations observed between the measured dimensions obtained from both techniques were within the uncertainties of the experiment. Moreover, the scaling of the structures’ size versus etching time (i.e. the etching rates) extracted from STIM and SEM data were equivalent. Prolonged etching times of up to 60 min were performed to check the effect of the irradiation on the non-bombarded vicinity of the structured lines. STIM images clearly revealed a distribution of cavities and porosity along the structured walls for etching times above 20 min. This is attributed to thermal effects and outgassing during the proton beam writing, which probably create voids that are enlarged by the long exposure to the etching solution

  4. Foil-less plasma-filled diode for HPM generator

    Science.gov (United States)

    Eltchaninov, A. A.; Kovalchuk, B. M.; Kurkan, I. K.; Zherlitsyn, A. A.

    2014-11-01

    Plasma-filled diode regarded as perspective source of electron beam feeding HPM generator of GW power level, comparing to conventional explosive emission vacuum diode. Electron beam generation occurs in plasma double layer, where plasma boundary plays as an anode. It allows cancelling the usage of anode foils or grids in HPM generators with the virtual cathode, which could limit its life time to few shots. The presence of ions in the e-beam drift space could raise the limiting current for a drift space, but it could affect to microwave generation also. Sectioned plasma-filled diode with beam current of about 100 kA, electron beam energy of about 0.5 MV and beam current density of 1-10 kA/cm2 was realized. Cylindrical transport channel with the diameter of 200 mm and the length of about 30 cm was attached to the diode. Beam current measurements in a drift space were performed. Computer simulations of electron beam transport with the presence of ions were carried out with the 2.5D axisymmetric version of PiC-code KARAT. Obtained results would help optimizing electrodynamic system of HPM generator subjected to the presence of ions.

  5. Foil-less plasma-filled diode for HPM generator

    International Nuclear Information System (INIS)

    Plasma-filled diode regarded as perspective source of electron beam feeding HPM generator of GW power level, comparing to conventional explosive emission vacuum diode. Electron beam generation occurs in plasma double layer, where plasma boundary plays as an anode. It allows cancelling the usage of anode foils or grids in HPM generators with the virtual cathode, which could limit its life time to few shots. The presence of ions in the e-beam drift space could raise the limiting current for a drift space, but it could affect to microwave generation also. Sectioned plasma-filled diode with beam current of about 100 kA, electron beam energy of about 0.5 MV and beam current density of 1-10 kA/cm2 was realized. Cylindrical transport channel with the diameter of 200 mm and the length of about 30 cm was attached to the diode. Beam current measurements in a drift space were performed. Computer simulations of electron beam transport with the presence of ions were carried out with the 2.5D axisymmetric version of PiC-code KARAT. Obtained results would help optimizing electrodynamic system of HPM generator subjected to the presence of ions

  6. Silicon oxide permeation barrier coating of PET bottles and foils

    Science.gov (United States)

    Steves, Simon; Deilmann, Michael; Awakowicz, Peter

    2009-10-01

    Modern packaging materials such as polyethylene terephthalate (PET) have displaced established materials in many areas of food and beverage packaging. Plastic packing materials offer are various advantages concerning production and handling. PET bottles for instance are non-breakable and lightweight compared to glass and metal containers. However, PET offers poor barrier properties against gas permeation. Therefore, the shelf live of packaged food is reduced. Permeation of gases can be reduced by depositing transparent plasma polymerized silicon oxide (SiOx) barrier coatings. A microwave (2.45 GHz) driven low pressure plasma reactor is developed based on a modified Plasmaline antenna to treat PET foils or bottles. To increase the barrier properties of the coatings furthermore a RF substrate bias (13.56 MHz) is applied. The composition of the coatings is analyzed by means of Fourier transform infrared (FTIR) spectroscopy regarding carbon and hydrogen content. Influence of gas phase composition and substrate bias on chemical composition of the coatings is discussed. A strong relation between barrier properties and film composition is found: good oxygen barriers are observed as carbon content is reduced and films become quartz-like. Regarding oxygen permeation a barrier improvement factor (BIF) of 70 is achieved.

  7. Optical fiber sensors embedded in flexible polymer foils

    Science.gov (United States)

    van Hoe, Bram; van Steenberge, Geert; Bosman, Erwin; Missinne, Jeroen; Geernaert, Thomas; Berghmans, Francis; Webb, David; van Daele, Peter

    2010-04-01

    In traditional electrical sensing applications, multiplexing and interconnecting the different sensing elements is a major challenge. Recently, many optical alternatives have been investigated including optical fiber sensors of which the sensing elements consist of fiber Bragg gratings. Different sensing points can be integrated in one optical fiber solving the interconnection problem and avoiding any electromagnetical interference (EMI). Many new sensing applications also require flexible or stretchable sensing foils which can be attached to or wrapped around irregularly shaped objects such as robot fingers and car bumpers or which can even be applied in biomedical applications where a sensor is fixed on a human body. The use of these optical sensors however always implies the use of a light-source, detectors and electronic circuitry to be coupled and integrated with these sensors. The coupling of these fibers with these light sources and detectors is a critical packaging problem and as it is well-known the costs for packaging, especially with optoelectronic components and fiber alignment issues are huge. The end goal of this embedded sensor is to create a flexible optical sensor integrated with (opto)electronic modules and control circuitry. To obtain this flexibility, one can embed the optical sensors and the driving optoelectronics in a stretchable polymer host material. In this article different embedding techniques for optical fiber sensors are described and characterized. Initial tests based on standard manufacturing processes such as molding and laser structuring are reported as well as a more advanced embedding technique based on soft lithography processing.

  8. Specific features of the clinical course and angiographic pattern of chronic coronary occlusion

    International Nuclear Information System (INIS)

    Particular features of coronary angiography and clinical presentation of myocardial ischemia (MI) have been studied in patients with chronic total coronary occlusion. Chronic total coronary occlusion is defined as TIMI 0 or TIMI 1 type flow in the artery for more than three days. MI patients with coronary occlusion have more severe course of coronary artery disease as compared to patients free of occlusion: they more often suffer myocardial infarction and high gradations of stenocardia. Myocardial function is much more affected it there is occlusion of left descending artery, or there are no signs of intercoronary collaterals

  9. Non-contact thickness measurement for ultra-thin metal foils with differential white light interferometry

    Institute of Scientific and Technical Information of China (English)

    Yanli Du(杜艳丽); Huimin Yan(严惠民); Yong Wu(吴勇); Xiaoqiang Yao(姚晓强); Yongjun Nie(聂永军); Baixuan Shi(施柏煊)

    2004-01-01

    A new differential white light interference technique for the thickness measurements of metal foil is presented. In this work, the differential white light system consists of two Michelson interferometers in tandem,and the measured reflective surfaces are the corresponding surfaces of metal foil. Therefore, the measuring result is only relative to the thickness but not the position of metal foil. The method is non-contact and non-destructive, it has the advantages of high accuracy, fast detection, and compact structure. Theoretical analysis and preliminary experimental verifications have shown that the technique can be used to measure the thickness of foil in the range of 1 to 80 μm with accuracy better than 0.08 μm.

  10. Electrophoretically applied dielectrics for amorphous metal foils used in pulsed power saturable reactors

    International Nuclear Information System (INIS)

    Amorphous metal foil-wound inductors have been tested as ferromagnetic saturable inductive elements for pulse-power (multi-terawatt) switching nodules. Saturation switching may provide large 100 ns current bursts necessary to accelerate ion beams for the fusion fuel pellet implosion required, for example, in PBFA (particle beam fusion accelerator) operation. In simulated capacitor testing premature dielectric breakdown of thin polyethylene terephthalate film insulation in the inductor windings occurs at considerably below 2500 V. This appears to be due to inadvertent dielectric damage from micro-spikes on the amorphous foil surface. Electron micrographs and dielectric breakdown data illustrate that electrophoretically-applied dielectric coatings, deposited from organic aqueous colloid dispersions, can be used to provide insulating coatings on the foil which provide a 240% improvement (6000 V) in the breakdown strength of wound amorphous foil inductors. The theory and operation of a dedicated electrophoretic continuous coating system is described

  11. A study of neutron fluence rates of the BNCT beam at THOR using foil activation

    International Nuclear Information System (INIS)

    Neutron fluence rates of the BNCT epithermal neutron beam at THOR were measured by using double-foil activation method free-in-air and in a water phantom. Foil sets consisting of gold, copper and manganese were used for measurements. Copper was used as an extra detector for quality check. Monte Carlo calculations using the MCNP4C code were conducted to support and compare with the measurement results. It was found that the calculation of reaction rates of foils free-in-air based on a neutron source with a coarse group energy structure is inadequate. The meetness of the assumptions on the neutron energy distribution made in the double-foil formulation for the determination of neutron fluence rates must be estimated in order to compare with the calculation. (author)

  12. LANL Experience Rolling Zr-Clad LEU-10Mo Foils for AFIP-7

    Energy Technology Data Exchange (ETDEWEB)

    Hammon, Duncan L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Clarke, Kester D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Alexander, David J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kennedy, Patrick K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Edwards, Randall L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Duffield, Andrew N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dombrowski, David E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-05-29

    The cleaning, canning, rolling and final trimming of Low Enriched Uranium-10 wt. pct. Molybdenum (LEU-10Mo) foils for ATR (Advanced Test Reactor) fuel plates to be used in the AFIP-7 (ATR Full Size Plate In Center Flux Trap Position) experiments are summarized. Six Zr-clad foils were produced from two LEU-10Mo castings supplied to Los Alamos National Laboratory (LANL) by Y-12 National Security Complex. Details of cleaning and canning procedures are provided. Hot- and cold-rolling results are presented, including rolling schedules, images of foils in-process, metallography and local compositions of regions of interest, and details of final foil dimensions and process yield. This report was compiled from the slides for the presentation of the same name given by Duncan Hammon on May 12, 2011 at the AFIP-7 Lessons Learned meeting in Salt Lake City, UT, with Los Alamos National Laboratory document number LA-UR 11-02898.

  13. Flexible supercapacitor electrodes with vertically aligned carbon nanotubes grown on aluminum foils

    Institute of Scientific and Technical Information of China (English)

    Itir Bakis Dogru; Mete Batuhan Durukan; Onur Turel; Husnu Emrah Unalan

    2016-01-01

    In this work, vertically aligned carbon nanotubes (VACNTs) grown on aluminum foils were used as flexible supercapacitor electrodes. Aluminum foils were used as readily available, cheap and conductive substrates, and VACNTs were grown directly on these foils through chemical vapor deposition (CVD) method. Solution based ultrasonic spray pyrolysis (USP) method was used for the deposition of the CNT catalyst. Direct growth of VACNTs on aluminum foils ruled out both the internal resistance of the su-percapacitor electrodes and the charge transfer resistance between the electrode and electrolyte. A specific capacitance of 2.61 mF/cm2 at a scan rate of 800 mV/s was obtained from the fabricated elec-trodes, which is further improved through the bending cycles.

  14. Effect of Trace Sn on Pitting Behaviors of High Voltage Anode Aluminum Foil

    Institute of Scientific and Technical Information of China (English)

    Jingbo SONG; Weimin MAO; Hong YANG; Huiping FENG

    2008-01-01

    The effect of trace Sn on the pitting morphology of high voltage anode aluminum foils was investigated. The distributions of microelement Sn, Fe, Si, Cu and Mg in the surface layer of aluminum foils with different Sn content were determined by using a secondary ion mass spectrometer. It was found that the micro-alloyed Sn is enriched at the external surface. The mechanism of pitting behavior of trace Sn on aluminum surface is similar with that of lead. Enrichment of Sn in the surface layer provides large numbers of sites for initiation of pitting corrosion, while pitting sites appeared relatively inhomogenously in the foils without Sn. Sn, as an eco-friendly microelement, can be applied to replace Pb in improving the homogenous pitting behaviors of high voltage aluminum foils, in which the volume fraction of cube texture is not reduced.

  15. Self-propelled swimming of a flexible plunging foil near a solid wall.

    Science.gov (United States)

    Dai, Longzhen; He, Guowei; Zhang, Xing

    2016-01-01

    Numerical simulations are conducted to investigate the influences of a solid wall on the self-propelled swimming of a flexible plunging foil. It is found that the presence of a solid wall enhances the cruising speed, with the cost of increasing input power. Rigid foil can achieve high percentage increase in cruising speed when swimming near a solid wall, but the propulsive efficiency may be reduced. Foils with some flexibility can enjoy the enhancements in both cruising speed and propulsive efficiency. Another advantage of the flexible foils in near-wall swimming is that smaller averaged lateral forces are produced. The effects of wall confinement on the wake structure and the vortex dynamics are also studied in this paper. The results obtained in this study shed some light on the unsteady wall effect experienced by aquatic animals and also inform the design of bio-mimetic underwater vehicles which are capable of exploiting the wall effect. PMID:27377880

  16. Intense heavy ion beam-induced temperature effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    At the future FAIR facility, reliably working solid carbon stripper foils are desired for providing intermediate charge states to SIS18. With the expected high beam intensities, the foils experience enhanced degradation and limited lifetime due to severe radiation damage, stress waves, and thermal effects. This work presents systematic measurements of the temperature of different carbon-based stripper foils (amorphous, diamond-like, and carbon-nanotube based) exposed to 4.8 MeV/u U, Bi, and Au beams of different pulse intensities. Thermal and spectroscopic analyses were performed by means of infrared thermography and Fourier transform infrared spectroscopy. The resulting temperature depends on the foil thickness and strongly increases with increasing pulse intensity and repetition rate. (author)

  17. Structure and corrosion resistance of nickel foils deposited in a vertical gravity field

    International Nuclear Information System (INIS)

    The effects of vertical gravity fields on the structural characteristics of electrodeposited Ni foils were investigated in a centrifuge. Analysis by atomic force microscopy (AFM) shows that the surface roughness of Ni foils reduces from 37.6 nm to 8.1 nm with the increase of gravity coefficient (G) from 1 to 354. Furthermore, the roughness of Ni foils deposited at G = 62 evolves much more slowly than that deposited at G = 1. The study of the textural perfection by X-ray diffractiometry (XRD) reveals that the degree of (2 0 0) preferred orientation parallel to the substrate plane is lowered by the vertical gravity field. Randomly oriented deposits are obtained in the vertical gravity field while deposits with uniaxial texture are obtained in the natural gravity field. Due to these variations in the structure, the Ni foils obtained in the vertical gravity field exhibit improved corrosion resistance.

  18. Gas Gain Measurement Of GEM-Foil In Argon-Carbon Dioxide Mixture

    International Nuclear Information System (INIS)

    Nuclear reaction measurement with radioactive beam at low energy plays an important role in nuclear astrophysics and nuclear structure. The trajectory of particle beams can be obtained by using an active gas target, multiple-sampling and tracking proportional chamber (MSTPC), as a proportional counter. Because of intensity of low energy radioactive beam, in the stellar reaction such as (α, p), (p, α), it is necessary to increase the gain for the counter. In this case, a gas electrons multiplier (GEM) foil will be used, so the proportional counter is called GEM-MSTPC. The efficient gas gain of GEM foils which relates to foil thickness and operating pressure was investigated with two type of the foils, 400 μm and 200 μm, in Argon (70%) + Carbon dioxide (30%) mixture. (author)

  19. Flexible supercapacitor electrodes with vertically aligned carbon nanotubes grown on aluminum foils

    Directory of Open Access Journals (Sweden)

    Itir Bakis Dogru

    2016-06-01

    Full Text Available In this work, vertically aligned carbon nanotubes (VACNTs grown on aluminum foils were used as flexible supercapacitor electrodes. Aluminum foils were used as readily available, cheap and conductive substrates, and VACNTs were grown directly on these foils through chemical vapor deposition (CVD method. Solution based ultrasonic spray pyrolysis (USP method was used for the deposition of the CNT catalyst. Direct growth of VACNTs on aluminum foils ruled out both the internal resistance of the supercapacitor electrodes and the charge transfer resistance between the electrode and electrolyte. A specific capacitance of 2.61 mF/cm2 at a scan rate of 800 mV/s was obtained from the fabricated electrodes, which is further improved through the bending cycles.

  20. Method to Increase Performance of Foil Bearings Through Passive Thermal Management

    Science.gov (United States)

    Bruckner, Robert

    2013-01-01

    This invention is a new approach to designing foil bearings to increase their load capacity and improve their reliability through passive thermal management. In the present case, the bearing is designed in such a way as to prevent the carryover of lubricant from the exit of one sector to the inlet of the ensuing sector of the foil bearing. When such passive thermal management techniques are used, bearing load capacity is improved by multiples, and reliability is enhanced when compared to current foil bearings. This concept has recently been tested and validated, and shows that load capacity performance of foil bearings can be improved by a factor of two at relatively low speeds with potentially greater relative improvements at higher speeds. Such improvements in performance with respect to speed are typical of foil bearings. Additionally, operation of these newly conceived bearings shows much more reliability and repeatable performance. This trait can be exploited in machine design to enhance safety, reliability, and overall performance. Finally, lower frictional torque has been demonstrated when operating at lower (non-load capacity) loads, thus providing another improvement above the current state of the art. The objective of the invention is to incorporate features into a foil bearing that both enhance passive thermal management and temperature control, while at the same time improve the hydrodynamic (load capacity) performance of the foil bearing. Foil bearings are unique antifriction devices that can utilize the working fluid of a machine as a lubricant (typically air for turbines and motors, liquids for pumps), and as a coolant to remove excess energy due to frictional heating. The current state of the art of foil bearings utilizes forced cooling of the bearing and shaft, which represents poor efficiency and poor reliability. This invention embodies features that utilize the bearing geometry in such a manner as to both support load and provide an inherent and

  1. Ultrastructural features of masseter muscle exhibiting altered occlusal relationship - a study in a rodent model

    International Nuclear Information System (INIS)

    The role of occlusion on Tempormandibular Disorders (TMD) is still unclear, mainly regarding muscular function. The aim of this study was to evaluate the occlusion highlights on masseter ultra morphology. Twenty Wistar rats were randomly divided in four groups: 10 for control group, 10 for occlusal alteration group (CCO). Rats underwent unilateral amputation of the left inferior and superior molar cusps to simulate an occlusal wear situation. The rats of control group had no occlusal wear. Half of the animals of each group was sacrificed in 14 days after the occlusal consuming and half 30 days after the occlusal consuming. The masseter muscles ipsilateral to the amputated molars were excised and processed for light microscopy, electron microscopy. The light microscopy did not show differences between the groups. The electron microscopy was able to detect a degree of intracellular damage in muscle fibers of CCO group: swollen mitochondria with disrupted cristae and cleared matrix, signs of hypercontraction of I bands and myofibril disorganization.

  2. Ultrastructural features of masseter muscle exhibiting altered occlusal relationship—a study in a rodent model

    Science.gov (United States)

    Lisboa, Marcio V.; Aciole, Gilberth T. S.; Oliveira, Susana C. P. S.; Marques, Aparecida M. C.; Baptista, Abrahão F.; Pinheiro, Antonio L. B.; Aguiar, Marcio C.; Santos, Jean N.

    2010-05-01

    The role of occlusion on Tempormandibular Disorders (TMD) is still unclear, mainly regarding muscular function. The aim of this study was to evaluate the occlusion highlights on masseter ultra morphology. Twenty Wistar rats were randomly divided in four groups: 10 for control group, 10 for occlusal alteration group (CCO). Rats underwent unilateral amputation of the left inferior and superior molar cusps to simulate an occlusal wear situation. The rats of control group had no occlusal wear. Half of the animals of each group was sacrificed in 14 days after the occlusal consuming and half 30 days after the occlusal consuming. The masseter muscles ipsilateral to the amputated molars were excised and processed for light microscopy, electron microscopy. The light microscopy did not show differences between the groups. The electron microscopy was able to detect a degree of intracellular damage in muscle fibers of CCO group: swollen mitochondria with disrupted cristae and cleared matrix, signs of hypercontraction of I bands and myofibril disorganization.

  3. Bonding bare die LEDs on PET foils for lighting applications: thermal design modeling and bonding experiments

    OpenAIRE

    van den Ende, Daan; Kusters, Roel; Cauwe, Maarten; A de Waal; van den Brand, Jeroen

    2012-01-01

    Integration of LEDs on flexible foil substrates is of interest for flexible lighting applications and flexible photonic devices. A matrix of LEDs on a foil combined with a diffuser can be a potential alternative for flexible OLED lighting devices. Preferably, these LEDs are integrated in an unpackaged, bare die form as it reduces cost, footprint and thickness. As a substrate, preferably low cost materials like polyesters (PET) are being used, especially for large area devices. However, the us...

  4. A review of progress and challenges in flapping foil power generation

    Science.gov (United States)

    Young, John; Lai, Joseph C. S.; Platzer, Max F.

    2014-05-01

    Power may be extracted from a flowing fluid in a variety of ways. Turbines using one or more oscillating foils are under increasingly active investigation, as an alternative to rotary wind turbines and river, oceanic and tidal current water turbines, although industrial development is at a very nascent stage. Such flapping foil turbines promise some key potential advantages, including lower foil velocities (and hence lower noise and wildlife impact), and more effective small-scale and shallow water operation. The role of a number of parameters is investigated, including foil kinematics (modes, frequencies, amplitudes and time histories of motion), foil and system geometry (shape, configuration and structural flexibility), and flow physics effects (Reynolds number and turbulence, shear flows and ground effect). Details of the kinematics are shown to have the single largest influence on power output and efficiency (measured as the ratio of power output to that available and accessible in the fluid stream). The highest levels of power and efficiency are associated with very large foil pitch angles (upwards of 70°) and angles of attack (30-40°), such that the flow is massively separated for much of the flapping cycle, in contrast to rotary turbines which rely on attached flow over as much of the rotor disk as possible. This leads to leading edge vortices comparable in size to the foil chord, and the evolution and interaction of these vortices with the foil as it moves play a central role in determining performance. The other parameters also influence the vortex behaviour, but in general to a lesser degree. Numerous gaps in the research literature and outstanding issues are highlighted.

  5. Gas-Dynamic Foil Bearings Application in High-Speed Turbines

    OpenAIRE

    Giemza Bolesław; Nowiński Emil; Domański Marek

    2015-01-01

    Authors present the general characteristics of the gas-dynamic foil bearings in the paper. The short analysis of the application and possibilities of using gas-dynamic bearings in turbo machinery, especially in the aspect of aviation technology were described. Authors also pointed out possible directions of development and gas-dynamic foil bearings application in high-speed turbines, especially working in high temperature.

  6. Analysis of a flapping foil system for energy harvesting at low Reynolds number

    OpenAIRE

    Cho, Hunkee

    2011-01-01

    The new type of power generation system which mimics the flapping motion of insects or fish has been studied in recent years. The biological flapping foil is capable of harvesting energy from incoming wind or current. A non- sinusoidal trajectory profile and linear shear inlet profile are proposed for the flapping foil in the energy harvesters instead of conventional sinusoidal plunging and pitching motions to get better energy harvesting performance. In this study we create a numerical model...

  7. Control of Oscillating Foil for Propulsion of Biorobotic Autonomous Underwater Vehicle (AUV)

    OpenAIRE

    Singh, S. N.; Mani, S.

    2005-01-01

    The paper treats the question of control of a laterally and rotationally oscillating hydrofoil for the propulsion of biologically inspired robotic (biorobotic) autonomous underwater vehicles (BAUVs). Sinusoidal oscillations of foils produce maneuvering and propulsive forces. The design is based on the internal model principle. Two springs are used to transmit forces from the actuators to the foil. Oscillating fins produce periodic forces, which can be used for fish-like propulsion and control...

  8. Study of the strata formation during the explosion of foils in vacuum

    Science.gov (United States)

    Zhigalin, A. S.; Rousskikh, A. G.; Oreshkin, V. I.; Chaikovsky, S. A.; Ratakhin, N. A.; Khishchenko, K. V.; Baksht, R. B.

    2015-11-01

    The formation of the strata during fast explosion of metal foils at current densities of 0.1 GA/cm2 has been studied experimentally. To observe the strata, the soft x-ray radiation generated by an X-pinch was used. The study of the process of stratification during the foil explosion was carried out with a setup consisting of three generators. One of the generators (WEG-2), was operated to initiate the explosion of the foils, while the others (XPG radiographs) were used for diagnostics. The generator WEG-2 has the capacitance of 250 nF, the charge voltage of 20 kV, and the current rate of 16 A/ns. The radiographs XPG have the capacitance of 1 μF, the charge voltage of 43 kV, the current of 300 kA, and the current rise time of 180 ns. X-pinch produced by four Mo wires was a load for the radiographs. The delay between the operation of the WEG-2 and XPG generators was set using a DPG trigger pulse generator. We performed the experiments with the Al and Cu foils. The length of foil was 2 cm, the foil width was 1 mm, and the foil thickness was 6 μm. It has been revealed that strata were formed early in the explosion, i.e. at the stage when the metal melted. Analysis of the experimental results suggests that the most probable reason for the stratification is the thermal instability developing because of the increase in resistivity of the foil metal with temperature.

  9. Foil fatigue sensor for «Structural Health Monitoring» systems

    Directory of Open Access Journals (Sweden)

    М. В. Карускевич

    2013-07-01

    Full Text Available The concept of foil fatigue sensor is presented. The deformation relief of the sensor surface is considered as an indicator of the fatigue damage. The quantitative parameter of the deformation relief intensity determined by the computer aided method is applied.   The possibility to monitor fatigue damage of metal structures by the application of foil fatigue sensor is proved. The method  to control sensitivity of the sensors is shown

  10. Foil fatigue sensor for «Structural Health Monitoring» systems

    OpenAIRE

    М.В. Карускевич; О.Ю. Корчук; М. В. Лісовська

    2013-01-01

    The concept of foil fatigue sensor is presented. The deformation relief of the sensor surface is considered as an indicator of the fatigue damage. The quantitative parameter of the deformation relief intensity determined by the computer aided method is applied.   The possibility to monitor fatigue damage of metal structures by the application of foil fatigue sensor is proved. The method  to control sensitivity of the sensors is shown

  11. Simultaneous Elastic Recoil Detection Analysis of H and Other Elements in Foils

    Institute of Scientific and Technical Information of China (English)

    LU Xiu-Qin; ZHOU Ping; GUO Ji-Yu; ZHANG Xin; ZHAO Kui; NI Mei-Nan; SUI Li; MEI Jun-Ping; LIU Jian-Cheng

    2005-01-01

    @@ Hydrogen and other elements in SixNyHz foils have been simultaneously measured by using a single E(gas)- E(PSD) telescope and heavy 127I ion beam in elastic recoil detection analysis (ERDA). Hydrogen is measuredin the non-coincidence spectrum of E(PSD), and other elements from the △E - E coincidence spectrum. Thecomposition and depth profiling of the foils are obtained from the simulated spectra.

  12. Modeling the transmission of beta rays through thin foils in planar geometry.

    Science.gov (United States)

    Stanga, D; De Felice, P; Keightley, J; Capogni, M; Ionescu, E

    2016-01-01

    This paper is concerned with the modeling of the transmission of beta rays through thin foils in planar geometry based on the plane source concept, using Monte Carlo simulation of electron transport and least squares fitting. Applications of modeling results for calculating the efficiency of large-area beta sources, transmission coefficient of beta rays through thin foils and the beta detection efficiency of large-area detectors used in surface contamination measurements are also presented. PMID:26524407

  13. Preparation and investigation of diamond-like carbon stripper foils by filtered cathodic vacuum arc

    International Nuclear Information System (INIS)

    Thin diamond-like carbon (DLC) stripper foils ∼5μg/cm2 in thickness were produced and evaluated as heavy-ion strippers for the Beijing HI-13 Tandem Accelerator. The DLC layers ∼4μg/cm2 in thickness were produced by the filtered cathodic vacuum arc technology onto glass slides coated with betaine–saccharose as releasing agent, which were previously covered with evaporated carbon layers ∼1μg/cm2 in thickness by the controlled ac arc-discharge method. Irradiation lifetimes of the DLC stripper foils were tested using the heavy-ion beams at the terminal of the Beijing HI-13 Tandem Accelerator, and compared with those of the standard carbon stripper foils made by the combined dc and ac arc-discharge method. The measurements indicate that the DLC stripper foils outlast the standard combined dc and ac arc-discharge carbon stripper foils by a factor of at least 13 and 4 for the 197Au− (∼9MeV, ∼1μA) and 63Cu− (∼9MeV, ∼1μA) ion beams, respectively. The structure and properties of the DLC foils deposited onto silicon substrates by the filtered cathodic vacuum arc technology were also evaluated and analyzed by scanning electron microscopy, Raman spectroscopy and X-ray photoelectron spectroscopy. The scanning electron microscopy images show that the DLC foils contain hardly droplets through the double 90° filters. The X-ray photoelectron spectrum indicates that sp3 bonds of the DLC foils exceed 70%. The integral intensity ratio of the D peak to the G peak (ID/IG) measured by the Raman spectroscopy is 0.78

  14. Conceptual Design and Feasibility of Foil Bearings for Rotorcraft Engines: Hot Core Bearings

    Science.gov (United States)

    Howard, Samuel A.

    2007-01-01

    Recent developments in gas foil bearing technology have led to numerous advanced high-speed rotating system concepts, many of which have become either commercial products or experimental test articles. Examples include oil-free microturbines, motors, generators and turbochargers. The driving forces for integrating gas foil bearings into these high-speed systems are the benefits promised by removing the oil lubrication system. Elimination of the oil system leads to reduced emissions, increased reliability, and decreased maintenance costs. Another benefit is reduced power plant weight. For rotorcraft applications, this would be a major advantage, as every pound removed from the propulsion system results in a payload benefit.. Implementing foil gas bearings throughout a rotorcraft gas turbine engine is an important long-term goal that requires overcoming numerous technological hurdles. Adequate thrust bearing load capacity and potentially large gearbox applied radial loads are among them. However, by replacing the turbine end, or hot section, rolling element bearing with a gas foil bearing many of the above benefits can be realized. To this end, engine manufacturers are beginning to explore the possibilities of hot section gas foil bearings in propulsion engines. This overview presents a logical follow-on activity by analyzing a conceptual rotorcraft engine to determine the feasibility of a foil bearing supported core. Using a combination of rotordynamic analyses and a load capacity model, it is shown to be reasonable to consider a gas foil bearing core section. In addition, system level foil bearing testing capabilities at NASA Glenn Research Center are presented along with analysis work being conducted under NRA Cooperative Agreements.

  15. Dynamics of laser mass-limited foil interaction at ultra-high laser intensities

    Energy Technology Data Exchange (ETDEWEB)

    Yu, T. P., E-mail: tongpu@nudt.edu.cn [College of Science, National University of Defense Technology, Changsha 410073 (China); State Key Laboratory of High Performance Computing, National University of Defense Technology, Changsha 410073 (China); Sheng, Z. M. [Key Laboratory for Laser Plasmas (MoE) and Department of Physics, Shanghai Jiao Tong University, Shanghai 200240 (China); SUPA, Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Yin, Y.; Zhuo, H. B.; Ma, Y. Y.; Shao, F. Q. [College of Science, National University of Defense Technology, Changsha 410073 (China); Pukhov, A. [Institut für Theoretische Physik I, Heinrich-Heine-Universität Düsseldorf, 40225 Düsseldorf (Germany)

    2014-05-15

    By using three-dimensional particle-in-cell simulations with synchrotron radiation damping incorporated, dynamics of ultra-intense laser driven mass-limited foils is presented. When a circularly polarized laser pulse with a peak intensity of ∼10{sup 22} W/cm{sup 2} irradiates a mass-limited nanofoil, electrons are pushed forward collectively and a strong charge separation field forms which acts as a “light sail” and accelerates the protons. When the laser wing parts overtake the foil from the foil boundaries, electrons do a betatron-like oscillation around the center proton bunch. Under some conditions, betatron-like resonance takes place, resulting in energetic circulating electrons. Finally, bright femto-second x rays are emitted in a small cone. It is also shown that the radiation damping does not alter the foil dynamics radically at considered laser intensities. The effects of the transverse foil size and laser polarization on x-ray emission and foil dynamics are also discussed.

  16. Stripper foil failure modes and cures at the Oak Ridge Spallation Neutron Source

    Science.gov (United States)

    Plum, M. A.; Cousineau, S. M.; Galambos, J.; Kim, S. H.; Ladd, P.; Luck, C. F.; Peters, C. C.; Polsky, Y.; Shaw, R. W.; Macek, R. J.; Raparia, D.

    2011-03-01

    The Oak Ridge Spallation Neutron Source comprises a 1 GeV, 1.5 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the H0 excited states created during the H- charge-exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming H- beam, which circled around to strike the foil bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we detail these and other interesting failure mechanisms and describe the improvements we have made to mitigate them.

  17. PENGEMBANGAN FOIL NACA SERI 2412 SEBAGAI SISTEM PENYELAMAN MODEL KAPAL SELAM

    Directory of Open Access Journals (Sweden)

    Ali Munazid

    2015-06-01

    Full Text Available Bentuk  foil menghasilkan gaya angkat (lift force ketika foil dilewati oleh aliran fluida  karena adanya pengaruh interaksi antara aliran fluida dengan permukaan foil yang mengakibatkan tekanan permukaan atas lebih kecil dari permukaan bawah. Bagaimana mengaplikasikan teori foil pada hydroplane kapal selam sebagai  system penyelaman, dengan membalik foil maka lift force tersebut menjadi gaya ke bawah, dengan demikian memungkinkan kapal selam dapat menyelam, melayang dan bermanouver di bawah air, seperti halnya gerak pesawat terbang yang terbang dan melayang dengan menggunakan sayap. Dilakukan penelitian dan pengamatan terhadap kemampuan penyelaman (diving plan dari foil NACA seri 2412 pada model kapal selam, dengan mencari nilai Cl (coefisien lift di Laboratorium, serta mendesain bentuk badan kapal selam dan analisa gaya-gaya yang bekerja pada model kapal selam, jumlah gaya-gaya yang bekerja keatas lebih rendah dari gaya-gaya ke bawah maka kapal selam mampu menyelam. Penerapan Hydroplane sebagai diving plane dapat diterapkan, kemampuan penyelaman dipengaruhi oleh sudut flip  Hydroplane dan kecepatan model, semakin besar kecepatan dan sudut flip maka semakin besar kedalaman penyelaman yang dapat dilakukan.

  18. Deformation Behaviors of HIPped Foil Compared with Those of Sheet Titanium Alloys

    Science.gov (United States)

    Castelli, Michael G.

    1999-01-01

    Micromechanics-based modeling of composite material behaviors requires an accurate assessment of the constituent properties and behaviors. For the specific case of continuous-fiber-reinforced metal matrix composites (MMC's) manufactured from a foil/fiber/foil process, much emphasis has been placed on characterizing foil-based matrix materials that have been fabricated in the same way as the composite. Such materials are believed to yield mechanical properties and behaviors that are representative of the matrix constituent within the composite (in situ matrix). Therefore, these materials are desired for micromechanics modeling input. Unfortunately, such foils are extremely expensive to fabricate and procure because of the labor-intensive rolling process needed to produce them. As a potential solution to this problem that would maintain appropriately representative in situ properties, the matrix constituent could be characterized with sheet-based materials, which are considerably less expensive to manufacture than foils, are more readily procured, and result in fewer plies to obtain a desired panel thickness. The critical question is, however, does the consolidated sheet material exhibit the same properties and behaviors as do the consolidated foils? Researchers at NASA Lewis Research Center's Life Prediction Branch completed a detailed experimental investigation to answer this question for three titanium alloys commonly used in metal matrix composite form.

  19. Flapping Dynamics of an Inverted Flexible Foil in a Uniform Axial Flow

    Science.gov (United States)

    Gurugubelli Venkata, Pardha Saradhi; Jaiman, Rajeev K.

    2014-11-01

    This work presents a numerical study on self-induced flapping dynamics of an inverted flexible foil in uniform flow. The inverted foil considered in this study is clamped at the trailing edge and the leading edge is allowed to oscillate. A high-order coupled FSI solver based on CFEI formulation has been used to present the flapping response results for a wide range of nondimensional bending rigidity using a fixed Reynolds number of 1000 and a mass-ratio of 0.1. As a function of bending rigidity four flapping regimes have been discovered: fixed point, inverted limit-cycle oscillation, deflected flapping, and flipped flapping. The inverted foil configuration undergoes flapping motion more readily and experiences very large amplitude oscillations than the conventional foil. A wide variety of vortex wakes with a maximum of 14 vortices per oscillation cycle have been observed. The inverted limit-cycle flapping generate novel 4P +6S (14 vortices) and 2P +6S (10 vortices) wakes. On the other hand, the flipped flapping regime is characterized by a von Kármán wake. We also observe that inverted foil can extract 1000 times more energy from the surrounding fluid compared to the conventional foil.

  20. Characteristics of flow over traveling wavy foils in a side-by-side arrangement

    Science.gov (United States)

    Dong, Gen-Jin; Lu, Xi-Yun

    2007-05-01

    Flow over traveling wavy foils in a side-by-side arrangement has been numerically investigated using the space-time finite element method to solve the two-dimensional incompressible Navier-Stokes equations. The midline of each foil undergoes lateral motion in the form of a streamwise traveling wave, which is similar to the backbone undulation of swimming fish. Based on the phase difference between the adjacent undulating foils, two typical cases, i.e., in-phase and anti-phase traveling wavy movements, are considered in the present study. The effects of lateral interference among the foils on the forces, power consumption, propeller efficiency, and flow structures are analyzed. It is revealed that the lateral interference is of benefit to saving the swimming power in the in-phase case and enhancing the forces in the anti-phase case. Some typical vortex structures, e.g., vortex-pair row, single vortex row, and in-phase and anti-phase synchronized vortex-street, are observed in the wake of the traveling wavy foils. The results obtained in this study provide physical insight into the understanding of hydrodynamics and flow structures for flow over the traveling wavy foils and swimming mechanisms relevant to fish schooling.

  1. The development of uranium foil farication technology utilizing twin roll method for Mo-99 irradiation target

    International Nuclear Information System (INIS)

    MDS Nordion in Canada, occupying about 75% of global supply of Mo-99 isotope, has provided the irradiation target of Mo-99 using the rod-type UAlx alloys with HEU(High Enrichment Uranium). ANL (Argonne National Laboratory) through co-operation with BATAN in Indonesia, leading RERTR (Reduced Enrichment for Research and Test Reactors) program substantially for nuclear non-proliferation, has designed and fabricated the annular cylinder of uranium targets, and successfully performed irradiation test, in order to develop the fabrication technology of fission Mo-99 using LEU(Low Enrichment Uranium). As the uranium foils could be fabricated in laboratory scale, not in commercialized scale by hot rolling method due to significant problems in foil quality, productivity and economic efficiency, attention has shifted to the development of new technology. Under these circumstances, the invention of uranium foil fabrication technology utilizing twin-roll casting method in KAERI is found to be able to fabricate LEU or HEU foils. Uranium and uranium alloy foils are fabricated through twin-roll casting of a uranium melt without a hot-rolling process and heat-treatment process. An improvement in productivity and process economics due to process simplification and better quality from the absence of any residual stress on the foil are expected through this research project

  2. Spin-polarized radioactive isotope beam produced by tilted-foil technique

    Energy Technology Data Exchange (ETDEWEB)

    Hirayama, Yoshikazu, E-mail: yoshikazu.hirayama@kek.jp [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK), Ibaraki 305-0801 (Japan); Mihara, Mototsugu [Department of Physics, Osaka University, Osaka 560-0043 (Japan); Watanabe, Yutaka; Jeong, Sun-Chan; Miyatake, Hiroari [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK), Ibaraki 305-0801 (Japan); Momota, Sadao [Kochi University of Technology, Kochi 782-8502 (Japan); Hashimoto, Takashi; Imai, Nobuaki [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK), Ibaraki 305-0801 (Japan); Matsuta, Kensaku [Department of Physics, Osaka University, Osaka 560-0043 (Japan); Ishiyama, Hironobu [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK), Ibaraki 305-0801 (Japan); Ichikawa, Shin-ichi; Ishii, Tetsuro [Japan Atomic Energy Agency (JAEA), Ibaraki 319-1195 (Japan); Izumikawa, Takuji [Radioisotope Center, Niigata University, Niigata 951-8510 (Japan); Katayama, Ichiro; Kawakami, Hirokane [Institute of Particle and Nuclear Studies (IPNS), High Energy Accelerator Research Organization (KEK), Ibaraki 305-0801 (Japan); Kawamura, Hirokazu [Department of Physics, Rikkyo University, Tokyo 171-8501 (Japan); Nishinaka, Ichiro; Nishio, Katsuhisa; Makii, Hiroyuki; Mitsuoka, Shin-ichi [Japan Atomic Energy Agency (JAEA), Ibaraki 319-1195 (Japan); and others

    2013-12-15

    Highlights: • Detail study for tilted foil technique. • New equation for estimating nuclear polarization dependence on the beam energy. • Production of nuclear polarization for heaviest nucleus {sup 123}In in ground state. -- Abstract: The tilted-foil method for producing spin-polarized radioactive isotope beams has been studied using the re-accelerated radioactive {sup 8}Li and {sup 123}In beams produced at Tokai Radioactive Ion Accelerator Complex (TRIAC) facility. We successfully produced polarization in a {sup 8}Li beam of 7.3(5)% using thin polystyrene foils (4.2 μg/cm{sup 2}). The systematic study of the nuclear polarization as a function of the number of foils and beam energy has been performed, confirming the features of the tilted-foil technique experimentally. After the study, a spin-polarized radioactive {sup 123}In beam, which is the heaviest ever polarized in its ground state by this method, has been successfully generated by the tilted-foil method, for the nuclear spectroscopy around the doubly magic nucleus {sup 132}Sn.

  3. Development of a twin-flapping-foils unit to generate hydroelectric power from a water current

    Science.gov (United States)

    Abiru, H.; Yoshitake, A.; Nishi, M.

    2014-03-01

    Most of the conventional hydraulic turbines have been used for those sites having the static head larger than around 1 m. To extensively utilize not only large hydro-power but small one, which is one of renewable energy resources, development of an energy conversion system being operable under an extremely low head stream is crucial. A twin-flapping-foils unit which works based on the lift acting on the flapping foils in a stream is proposed. The foils oscillate in the transverse direction of the flow due to the lift. The pitching motion of the foils is caused by their own transverse movement through the mechanism consisting of crankshafts and con-rods. In the unit, each foil is supported vertically with a shaft in a manner of a cantilever so that no other parts need to be submerged in a water current. An experimental model with symmetric foils of 100 mm chord and 300 mm span was designed to generate average power output of 10 W at a flow velocity of 1 m/s. Through the tests carried out in the circulating water channel, the performance of the unit was verified to satisfy the design specifications. Further, the demonstration tests by using an irrigation stream performed for over a half year clarified the performance equivalent to that in the in-door water channel and the durability to a certain extent, and showed the applicability to the practical use of lighting a LED street lamp during night even at this scale model.

  4. Development of a twin-flapping-foils unit to generate hydroelectric power from a water current

    International Nuclear Information System (INIS)

    Most of the conventional hydraulic turbines have been used for those sites having the static head larger than around 1 m. To extensively utilize not only large hydro-power but small one, which is one of renewable energy resources, development of an energy conversion system being operable under an extremely low head stream is crucial. A twin-flapping-foils unit which works based on the lift acting on the flapping foils in a stream is proposed. The foils oscillate in the transverse direction of the flow due to the lift. The pitching motion of the foils is caused by their own transverse movement through the mechanism consisting of crankshafts and con-rods. In the unit, each foil is supported vertically with a shaft in a manner of a cantilever so that no other parts need to be submerged in a water current. An experimental model with symmetric foils of 100 mm chord and 300 mm span was designed to generate average power output of 10 W at a flow velocity of 1 m/s. Through the tests carried out in the circulating water channel, the performance of the unit was verified to satisfy the design specifications. Further, the demonstration tests by using an irrigation stream performed for over a half year clarified the performance equivalent to that in the in-door water channel and the durability to a certain extent, and showed the applicability to the practical use of lighting a LED street lamp during night even at this scale model

  5. Internal carotid pseudo-occlusion: early and late results.

    Science.gov (United States)

    Pulli, R; Frosini, P; Gatti, M; Narcetti, S; Bernacchi, R; Pratesi, C

    1997-02-01

    Internal carotid pseudo-occlusion (ICP) is a pathology of difficult diagnostic evaluation and treatment in the group of extracranial carotid diseases. The authors report the results of 24 ICP(S) surgically treated in the last five years. No perioperative death was reported. The neurological morbility rate was as low as 4% (1/24), which is quite a good results for this high-risk pathology. Clinical and instrumental follow-up was performed (at 1-3-6-12-24 months from surgery). Six early asymptomatic thromboses (25%) were observed, and the remaining patients showed patent vessels and no symptoms at all. In conclusion surgical treatment of ICP is often able to prevent cerebral ischaemia, and the high rate of early occlusion should not limit surgical indication. PMID:9128116

  6. Comparative Analysis of Partial Occlusion Using Face Recognition Techniques

    Directory of Open Access Journals (Sweden)

    N.Nallammal

    2013-04-01

    Full Text Available This paper presents a comparison of partial occlusion using face recognition techniques that gives in which technique produce better result for total success rate. The partial occlusion of face recognition is especially useful for people where part of their face is scarred and defect thus need to be covered. Hence, either top part/eye region or bottom part of face will be recognized respectively. The partial face information are tested with Principle Component Analysis (PCA, Non-negative matrix factorization (NMF, Local NMF (LNMF and Spatially Confined NMF (SFNMF. The comparative results show that the recognition rate of 95.17% with r = 80 by using SFNMF for bottom face region. On the other hand, eye region achieves 95.12% with r = 10 by using LNMF.

  7. Vascular endothelial growth factor blocking agents in retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Chris Canning

    2008-01-01

    Full Text Available This paper summarises the current status of the use of vascular endothelial growth factor (VEGF blocking agents in retinal vein occlusion. There have been no randomised controlled trials comparing this treatment with the current standard treatment (largely laser so the lower grade evidence of single treatment case series and anecdotal reports are discussed. VEGF blockers are good at reducing macular oedema in the short term, do improve visual acuity in many cases, and do not seem to adversely affect the long term revascularisation that is necessary to overcome the vein occlusion. VEGF blocking agents are not used in isolation in this condition - they will remain an adjunct to systemic and other local treatments. The literature was reviewed in online searches of Embase and Ovid and the papers quoted are a representative sample of a larger body of publications.

  8. Ocular neovascularization in eyes with a central retinal artery occlusion or a branch retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Mason lll JO

    2015-06-01

    Full Text Available John O Mason III,1,2 Shyam A Patel,1 Richard M Feist,1,2 Michael A Albert Jr,1,2 Carrie Huisingh,1 Gerald McGwin Jr,1,3 Martin L Thomley1,2 1Department of Ophthalmology, University of Alabama School of Medicine, Birmingham, AL, USA; 2Retina Consultants of Alabama, Callahan Eye Foundation Hospital, Birmingham, AL, USA; 3Department of Epidemiology, School of Public Health, University of Alabama at Birmingham, Birmingham, AL, USA Purpose: To investigate the ocular neovascularization (ONV rate in eyes with a branch retinal artery occlusion (BRAO or a central retinal artery occlusion (CRAO, and to study factors that may influence the ONV rate secondary to CRAO.Methods: This was a retrospective case series of consecutive patients (286 total eyes: 83 CRAOs and 203 BRAOs who were diagnosed with a retinal artery occlusion from 1998 to 2013 at the Retina Consultants of Alabama and University of Alabama at Birmingham, Birmingham, AL, USA. Generalized estimating equations were used to evaluate the association between hypothesized risk factors and ONV development.Results: Twelve (14.5% of the 83 eyes with a CRAO developed ONV. Eleven of 12 eyes (91.7% had iris neovascularization, ten of 12 eyes (83.3% had neovascular glaucoma, and two of 12 eyes (16.7% had neovascularization of the optic disc. The average time for ONV development secondary to CRAO was 30.7 days, ranging from the date of presentation to 137 days. Only two (<1.0% of the 203 eyes with a BRAO developed iris neovascularization. Diabetes mellitus type 2 was a risk factor for ONV development following a CRAO with an adjusted odds ratio of 5.2 (95% confidence interval: 1.4–19.8 (P=0.02.Conclusion: ONV is an important complication of CRAO and is a less-frequent complication of BRAO. Patients with a CRAO, especially those with diabetes mellitus type 2, should be closely monitored for the first 6 months for ONV. Keywords: neovascularization, neovascular glaucoma, retinal artery occlusion, central

  9. Intravitrel bevacizumab in different type of retinal vein occlusions

    International Nuclear Information System (INIS)

    Background: Retinal vein occlusion is frequent cause of visual loss with insufficient treatment options. Many treatment options have been tried in the past including intravitreal triamcenoloneacetonide injection. This study was conducted to evaluate the efficacy and complications of intravitreal injection of Bevacizumab in different types of retinal vein occlusion. Method: This interventional study was carried out at Al Ibrahim eye hospital, Karachi from July 2011 to December 2012. Patients diagnosed with retinal vein occlusion of any type were included in the study using non-probability purposive sampling technique, after informed written consent. Patients were injected intra-vitreally with Bevacizumab 1.25 mg/0.05 ml under sterilized technique in operation room. Best corrected visual acuity and optical coherence tomography was repeated in every follow up along with the detailed fundoscopy and intraocular pressure measurement. Data analysis was done using SPSS-20.0. Results: A total 278 patients were included in the study according to the inclusion and exclusion criteria. Mean age of the patients was 54.28 years (SD=5.62). Out of 278 patients included in the study, 132 had BRVO, 141 had CRVO while 5 had HRVO. Mean visual acuity before injection was 2.309 lines of Snellen's acuity chart read, with minimum of 1 line read and maximum of 4 lines read (standard deviation=l.00). After 12 weeks post injection, 92 patients read 7 lines (6/6) of Snellen's visual acuity chart. Mean visual acuity was 4.75 lines of Snellen's acuity chart read, with minimum of 1 line read and maximum of 7 lines read (standard deviation=1.00). 77 percentage of the patients had visual improvement after injection (p<0.05). Conclusion: Intravitreal bevacizumab injection is very effective in reducing macular thickness as well in improving visual acuity in all types of retinal vein occlusion. (author)

  10. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    OpenAIRE

    Kwon, Chang-Il; Lehman, Glen A.

    2016-01-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, ...

  11. New stent developments for peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.)

  12. Immediate Small Side Branch Occlusion after Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ostovan

    2007-09-01

    Full Text Available Background: Small side branches, albeit less important than their larger counterparts, have not yet received due attention in the literature. Nor has there ever been a comparison between drug-eluting stents and bare metal stents apropos side branch occlusion. The aim of this study was to compare the patency of small (≥0.5 and ≤1.5 mm in diameter side branches with respect to bare metal vs. drug-eluting stents immediately after their deployment.Methods: This prospective bi-center study, conducted between June 2005 and January 2007, enrolled 82 patients treated with ≥1 of two stents (TAXUSTM LiberteTM or LiberteTM. Side branches ≥0.5 and <1.5 mm in diameter arising from the main vessel at the lesion site were evaluated. Results: Thirty-eight patients were treated with 42 LiberteTM stents (58 side branches and forty-four patients with 50 TAXUSTM LiberteTM (102 side branches. The rate of small side branch occlusion was 35.3% (36 in the TAXUSTM LiberteTM group compared to 29.31% (15 in the LiberteTM group (P-value= 0.7. The presence of type 1 side branch morphology (Lefevre classification was the most powerful predictor of small side branch occlusion (P-value=0.03. Conclusion: This study shows that drug-eluting stents are not inferior to bare metal stents as regards small side branch occlusion during coronary stenting

  13. Major Artery Occlusion: a Rare Complication of Sickle Cell Disease

    OpenAIRE

    AGHA, Adnan; Al-Hakami, Mohammad; Shabbir, Ghulam

    2010-01-01

    Sickle cell disease is hereditary hemoglobinopathy which causes haemolytic anemia, vaso-occlusive crisis, ischemic injuries and many other morbidities like cerebral infarction. In this report, we describe a case of a young patient with sickle cell disease presenting with right-sided weakness and slurring of speech with examination confirming right-sided hemiparesis with motor aphasia. On further investigation, she was found to have frontotemporal infarction. On magnetic resonance imaging with...

  14. Major Artery Occlusion: a Rare Complication of Sickle Cell Disease

    OpenAIRE

    Adnan Agha

    2010-01-01

    Abstract: Sickle cell disease is hereditary hemoglobinopathy which causes haemolytic anemia, vaso-occlusive crisis, ischemic injuries and many other morbidities like cerebral infarction.  In this report, we describe a case of a young patient with sickle cell disease presenting with right-sided weakness and slurring of speech with examination confirming right-sided hemiparesis with motor aphasia. On further investigation, she was found to have frontotemporal infarction.  On magnetic resonance ...

  15. Incidence and Predictors of Radial Artery Occlusion Associated Transradial Catheterization

    OpenAIRE

    Tuncez, Abdullah; Kaya, Zeynettin; Aras, Dursun; Yıldız, Abdulkadir; Gül, Enes Elvin; Tekinalp, Mehmet; Karakaş, Mehmet Fatih; Kısacık, Halil Lütfü

    2013-01-01

    In this study, we sought to assess the incidence and predictors of radial artery occlusion (RAO), which is a significant complication of transradial cardiac catheterization. We prospectively evaluated the results of 106 patients who underwent coronary angiography and percutaneous coronary intervention (PCI) via the transradial approach (TRA). At the 3rd h of intervention, the radial artery was checked by palpation; color doppler ultrasonography was performed at the 24th h. Fluoroscopy duratio...

  16. Bilateral Central Vein Occlusion in a Case of Diaphragmatic Eventration

    OpenAIRE

    STER, Anda-Maria; Stan, Cristina; GHERVAN, Mihaela

    2014-01-01

    Central Retinal Vein Occlusion (CRVO) is a severe retinal pathology, which causes visual impairment usually after the age of 40. Mostly unilateral, less than 10% of cases are bilateral. Affected young adults (under the age of 40), usually exhibit a hidden, underlying systemic disease. Thorough testing has to be done in order to spot the pathogenic agent. We present the case of a 25 years old woman with bilateral CRVO caused by Diaphragmatic Eventration and Chronic Respiratory Failure.

  17. Bilateral central vein occlusion in a case of diaphragmatic eventration.

    Science.gov (United States)

    Ster, Anda-Maria; Stan, Cristina; Ghervan, Mihaela

    2014-09-01

    Central Retinal Vein Occlusion (CRVO) is a severe retinal pathology, which causes visual impairment usually after the age of 40. Mostly unilateral, less than 10% of cases are bilateral. Affected young adults (under the age of 40), usually exhibit a hidden, underlying systemic disease. Thorough testing has to be done in order to spot the pathogenic agent. We present the case of a 25 years old woman with bilateral CRVO caused by Diaphragmatic Eventration and Chronic Respiratory Failure. PMID:25705293

  18. Occlusal Grinding Pattern during Sleep Bruxism and Temporomandibular Disorder

    OpenAIRE

    Yeni Wijaya; Laura S. Himawan; Roselani W. Odang

    2013-01-01

    Sleep Bruxism is a significant etiology of temporomandibular disorder (TMD) and causes many dental or oral problems such as tooth wear or facet. There is no study analyzing the relationship between sleep bruxism and TMD. Objective: To investigate any relationship between occlusal grinding pattern during sleep bruxism and temporomandibular disorder. Methods: A cross-sectional study involving 30 sleep bruxism patients attended the Faculty Dentistry Universitas Indonesia Teaching Hospital (RSGMP...

  19. Therapeutic potential of intravitreal pharmacotherapy in retinal vein occlusion

    OpenAIRE

    2012-01-01

    Retinal vein occlusion (RVO) is the most common visually disabling disease affecting the retina after diabetic retinopathy. Although the disease entity has long been known, its management is still controversial. Macular edema is the main reason for decreased visual acuity (VA) in this retinal vascular disorder. Recently the vitreous cavity has increasingly been used as a reservoir of drugs for the direct treatment of macular edema through intravitreal injection route. The most widely injected...

  20. The relationship of occlusal disharmonies and symptoms of temporomandibular disorders

    Directory of Open Access Journals (Sweden)

    Dodić Slobodan

    2006-01-01

    Full Text Available Introduction: The influence of occlusal condition on the onset of temporomandibular disorder (TMD has been strongly debated for many years and is still the source of controversy. Until 1980s, the occlusal factors such as the presence of uncured malocclusions, discrepancies between intercuspal position (ICP and retruded contact position (RCP greater than two millimeters, occlusal abnormality, particularly mediotrusion and retrusion, and loss of posterior teeth were considered the primary causes of TMD. Objective: The objective of our study was to find correlation of occlusion disharmonies (difference between ICP and RCP and present sings and symptoms of TMD. Method: The study involved 60 subjects between 18 and 26 years of age who were divided in two groups. The study group consisted of 30 subjects between 18 and 26 years of age with sings and symptoms of temporomandibular disorders (TMD. TMD was confirmed according to Helkimo index. An average value of Helkimo index in this group was 1. The control group included 30 subjects between 20 and 25 years of age without TMD sings and symptoms. An average value of Helkimo index in this group was 0. The function analysis of cinematic centers position in RCP and ICP was performed in each subject using the computer pantograph Arcus-Digma (KaVo EWL GmbH, Leutkirch, Germany. Results: The results of our study showed that the translation tracing of cinematic points from RCP to ICP was significantly different in TMD subjects and asymptomatic group (p>0.16. In addition, the study revealed that 53.4 % of subjects with sings and symptoms of temporomandibular disorders had marked translation in the lower temporomandibular joint (0.61-1.2 mm what directed to intracapsular disorders. Conclusion: The results of our study suggested significant difference of RCP and ICP between subjects with sings and symptoms of the temporomandibular disorders and subjects without sings and symptoms.