WorldWideScience

Sample records for banding nanotool evaluation

  1. Calibration of optically trapped nanotools

    Energy Technology Data Exchange (ETDEWEB)

    Carberry, D M; Simpson, S H; Grieve, J A; Hanna, S; Miles, M J [H H Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Wang, Y; Schaefer, H; Steinhart, M [Institute for Chemistry, University of Osnabrueck, Osnabrueck (Germany); Bowman, R; Gibson, G M; Padgett, M J, E-mail: m.j.miles@bristol.ac.uk [SUPA, Department of Physics and Astronomy, University of Glasgow, Science Road, Glasgow G12 8QQ (United Kingdom)

    2010-04-30

    Holographically trapped nanotools can be used in a novel form of force microscopy. By measuring the displacement of the tool in the optical traps, the contact force experienced by the probe can be inferred. In the following paper we experimentally demonstrate the calibration of such a device and show that its behaviour is independent of small changes in the relative position of the optical traps. Furthermore, we explore more general aspects of the thermal motion of the tool.

  2. AFM Nanotools for Surgery of Biological Cells

    Energy Technology Data Exchange (ETDEWEB)

    Beard, J D; Gordeev, S N [Department of Physics, Claverton Down, University of Bath, Bath, BA2 7AY (United Kingdom); Guy, R H, E-mail: jdb28@bath.ac.uk [Department of Pharmacy and Pharmacology, Claverton Down, University of Bath, Bath, BA2 7AY (United Kingdom)

    2011-03-01

    Using a method of electron-beam induced deposition, we have been able to fabricate specialized AFM probes with application as 'nanotools' for the manipulation of biological structures ('nanosurgery'). We describe several such tools, including a 'nanoscalpel', 'nanoneedles' for probing intracellular structures, and a 'nanotome' which can separate surface layers from a biological structure. These applications are demonstrated by performing nanomanipulation on corneocyte cells from the outer layer of human skin.

  3. Application of a pilot control banding tool for risk level assessment and control of nanoparticle exposures.

    Science.gov (United States)

    Paik, Samuel Y; Zalk, David M; Swuste, Paul

    2008-08-01

    Control banding (CB) strategies offer simplified solutions for controlling worker exposures to constituents that are found in the workplace in the absence of firm toxicological and exposure data. These strategies may be particularly useful in nanotechnology applications, considering the overwhelming level of uncertainty over what nanomaterials and nanotechnologies present as potential work-related health risks, what about these materials might lead to adverse toxicological activity, how risk related to these might be assessed and how to manage these issues in the absence of this information. This study introduces a pilot CB tool or 'CB Nanotool' that was developed specifically for characterizing the health aspects of working with engineered nanoparticles and determining the level of risk and associated controls for five ongoing nanotechnology-related operations being conducted at two Department of Energy research laboratories. Based on the application of the CB Nanotool, four of the five operations evaluated in this study were found to have implemented controls consistent with what was recommended by the CB Nanotool, with one operation even exceeding the required controls for that activity. The one remaining operation was determined to require an upgrade in controls. By developing this dynamic CB Nanotool within the realm of the scientific information available, this application of CB appears to be a useful approach for assessing the risk of nanomaterial operations, providing recommendations for appropriate engineering controls and facilitating the allocation of resources to the activities that most need them.

  4. Self-propelled nanotools drilling into cells and tissues

    International Nuclear Information System (INIS)

    Sanchez, Samuel; Xi, Wang; Solovev, Alexander; Schmidt, Oliver

    2013-01-01

    We designed nanoscale tools in the form of autonomous and remotely guided catalytically and magnetically self-propelled micro- and nanotools. Asymmetrically rolled-up nanotools move in a corkscrewlike trajectory, allowing these tiny tubes to drill and embed themselves into biomaterials (fixed HeLa cells and tissues). First, we designed the smallest self-propelled nanojet engine (InGaAs/GaAs/(Cr)Pt) with diameters in the range of 280-600 nm, which move in hydrogen peroxide solutions with speeds as high as 180 μm.s -1 and perform advanced tasks such as drilling into cancer cells. Also, we demonstrated that tubular fuelfree Ti/Cr/Fe micro-drillers containing sharp tips can be applied for mechanical drilling operations of porcine liver tissue ex vivo. An external rotational magnetic field is used to remotely locate and actuate the micro-drillers in a solution with a viscosity comparable to that of biological fluids (e.g., blood). (authors)

  5. Evaluation of a color fused dual-band NVG

    NARCIS (Netherlands)

    Hogervorst, M.A.; Toet, A.

    2009-01-01

    We designed and evaluated a dual-band Night Vision Goggles sensor system. The sensor system consists of two optically aligned NVGs fitted with filters splitting the sensitive range into a visual and a near-infrared band. The Color-the-night technique (Hogervorst & Toet, FUSION2008) was used to fuse

  6. Mechanisms of cell death in canine parvovirus-infected cells provide intuitive insights to developing nanotools for medicine

    Directory of Open Access Journals (Sweden)

    Jonna Nykky

    2010-06-01

    Full Text Available Jonna Nykky, Jenni E Tuusa, Sanna Kirjavainen, Matti Vuento, Leona GilbertNanoscience Center and Department of Biological and Environmental Science, University of Jyväskylä, FinlandAbstract: Viruses have great potential as nanotools in medicine for gene transfer, targeted gene delivery, and oncolytic cancer virotherapy. Here we have studied cell death mechanisms of canine parvovirus (CPV to increase the knowledge on the CPV life cycle in order to facilitate the development of better parvovirus vectors. Morphological studies of CPV-infected Norden laboratory feline kidney (NLFK cells and canine fibroma cells (A72 displayed characteristic apoptotic events. Apoptosis was further confirmed by activation of caspases and cellular DNA damage. However, results from annexin V-propidium iodide (PI labeling and membrane polarization assays indicated disruption of the plasma membrane uncommon to apoptosis. These results provide evidence that secondary necrosis followed apoptosis. In addition, two human cancer cell lines were found to be infected by CPV. This necrotic event over apoptotic cell death and infection in human cells provide insightful information when developing CPV as a nanotool for cancer treatments.Keywords: canine parvovirus, apoptosis, necrosis, nanoparticle, virotherapy

  7. Shuttle orbiter Ku-band radar/communications system design evaluation. Deliverable test equipment evaluation

    Science.gov (United States)

    Maronde, R. G.

    1980-07-01

    The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.

  8. Evaluation of Model Microphysics Within Precipitation Bands of Extratropical Cyclones

    Science.gov (United States)

    Colle, Brian A.; Molthan, Andrew; Yu, Ruyi; Stark, David; Yuter, Sandra; Nesbitt, Steven

    2013-01-01

    Recent studies evaluating the bulk microphysical schemes (BMPs) within cloud resolving models (CRMs) have indicated large uncertainties and errors in the amount and size distributions of snow and cloud ice aloft. The snow prediction is sensitive to the snow densities, habits, and degree of riming within the BMPs. Improving these BMPs is a crucial step toward improving both weather forecasting and climate predictions. Several microphysical schemes in the Weather Research and Forecasting (WRF) model down to 1.33-km grid spacing are evaluated using aircraft, radar, and ground in situ data from the Global Precipitation Mission Coldseason Precipitation Experiment (GCPEx) experiment, as well as a few years (15 winter storms) of surface measurements of riming, crystal habit, snow density, and radar measurements at Stony Brook, NY (SBNY on north shore of Long Island) during the 2009-2012 winter seasons. Surface microphysical measurements at SBNY were taken every 15 to 30 minutes using a stereo microscope and camera, and snow depth and snow density were also recorded. During these storms, a vertically-pointing Ku-band radar was used to observe the vertical evolution of reflectivity and Doppler vertical velocities. A Particle Size and Velocity (PARSIVEL) disdrometer was also used to measure the surface size distribution and fall speeds of snow at SBNY. For the 15 cases at SBNY, the WSM6, Morrison (MORR), Thompson (THOM2), and Stony Brook (SBU-YLIN) BMPs were validated. A non-spherical snow assumption (THOM2 and SBU-YLIN) simulated a more realistic distribution of reflectivity than spherical snow assumptions in the WSM6 and MORR schemes. The MORR, WSM6, and SBU-YLIN schemes are comparable to the observed velocity distribution in light and moderate riming periods. The THOM2 is 0.25 meters per second too slow with its velocity distribution in these periods. In heavier riming, the vertical Doppler velocities in the WSM6, THOM2, and MORR schemes were 0.25 meters per second too

  9. Evaluation of a color fused dual-band NVG

    NARCIS (Netherlands)

    Hogervorst, M.A.; Toet, A.

    2009-01-01

    We have tested a prototype dual-band NVG system consisting of two NVGs fitted with filters that split the NVG sensitive range into a short (visual) and a long wavelength (NIR) band. The Color-the-night technique (see Hogervorst & Toet, SPIE D&S ‘08) was used to fuse the images of the two sensors. We

  10. Theoretical evaluation of maximum electric field approximation of direct band-to-band tunneling Kane model for low bandgap semiconductors

    Science.gov (United States)

    Dang Chien, Nguyen; Shih, Chun-Hsing; Hoa, Phu Chi; Minh, Nguyen Hong; Thi Thanh Hien, Duong; Nhung, Le Hong

    2016-06-01

    The two-band Kane model has been popularly used to calculate the band-to-band tunneling (BTBT) current in tunnel field-effect transistor (TFET) which is currently considered as a promising candidate for low power applications. This study theoretically clarifies the maximum electric field approximation (MEFA) of direct BTBT Kane model and evaluates its appropriateness for low bandgap semiconductors. By analysing the physical origin of each electric field term in the Kane model, it has been elucidated in the MEFA that the local electric field term must be remained while the nonlocal electric field terms are assigned by the maximum value of electric field at the tunnel junction. Mathematical investigations have showed that the MEFA is more appropriate for low bandgap semiconductors compared to high bandgap materials because of enhanced tunneling probability in low field regions. The appropriateness of the MEFA is very useful for practical uses in quickly estimating the direct BTBT current in low bandgap TFET devices.

  11. Evaluation of coronary band temperatures in healthy horses

    DEFF Research Database (Denmark)

    Rosenmeier, Jesper G.; Strathe, Anders Bjerring; Andersen, Pia Haubro

    2012-01-01

    To measure coronary band temperature (CBT) in healthy horses fed high-fructan or low-carbohydrate diets and to analyze the association of CBT with diet, time of day, and ambient temperature.......To measure coronary band temperature (CBT) in healthy horses fed high-fructan or low-carbohydrate diets and to analyze the association of CBT with diet, time of day, and ambient temperature....

  12. Experimental Evaluation of Cold-Sprayed Copper Rotating Bands for Large-Caliber Projectiles

    Science.gov (United States)

    2015-05-01

    process parameters used during the initial deposition of copper material, given the observation that these initial copper rotating bands tended to “ flake ...ARL-TR-7299 ● MAY 2015 US Army Research Laboratory Experimental Evaluation of Cold-Sprayed Copper Rotating Bands for Large...Experimental Evaluation of Cold-Sprayed Copper Rotating Bands for Large-Caliber Projectiles by Michael A Minnicino Weapons and Materials Research

  13. Prenatal and postnatal evaluation of polymicrogyria with band heterotopia.

    Science.gov (United States)

    Nagaraj, Usha D; Hopkin, Robert; Schapiro, Mark; Kline-Fath, Beth

    2017-09-01

    The coexistence of band heterotopia and polymicrogyria is extremely rare though it has been reported in the presence of corpus callosum anomalies and megalencephaly. We present prenatal and postnatal MRI findings of a rare case of diffuse cortical malformation characterized by polymicrogyria and band heterotopia. Agenesis of the corpus callosum and megalencephaly were also noted. In addition, bilateral closed-lip schizencephaly was identified on postnatal MRI, which has not been previously reported with this combination of imaging findings. Polymicrogyria with band heterotopia can occur and can be diagnosed with fetal MRI. The coexistence of corpus callosum anomalies and megalencephaly comprises a rare phenotype that has been previously described, suggesting an underlying genetic abnormality.

  14. Prenatal and postnatal evaluation of polymicrogyria with band heterotopia

    Directory of Open Access Journals (Sweden)

    Usha D. Nagaraj, MD

    2017-09-01

    Full Text Available The coexistence of band heterotopia and polymicrogyria is extremely rare though it has been reported in the presence of corpus callosum anomalies and megalencephaly. We present prenatal and postnatal MRI findings of a rare case of diffuse cortical malformation characterized by polymicrogyria and band heterotopia. Agenesis of the corpus callosum and megalencephaly were also noted. In addition, bilateral closed-lip schizencephaly was identified on postnatal MRI, which has not been previously reported with this combination of imaging findings. Polymicrogyria with band heterotopia can occur and can be diagnosed with fetal MRI. The coexistence of corpus callosum anomalies and megalencephaly comprises a rare phenotype that has been previously described, suggesting an underlying genetic abnormality.

  15. A comprehensive evaluation of the toxicology of experimental cigarettes manufactured with banded papers.

    Science.gov (United States)

    Werley, Michael S; Jerome, Ann M; DeSoi, Darren J; Coggins, Christopher R E; Oldham, Michael J; McKinney, Willie J

    2013-01-01

    To comply with state requirements, cigarette manufacturers have added low-permeability bands to the cigarette paper. These bands can extinguish the cigarette when it is no longer being puffed by a smoker. This study was conducted to evaluate the toxicology resulting from the addition of different types of bands to experimental cigarettes. A battery of assays that are typically used in toxicology studies with cigarette smoke, namely smoke chemistry, in vitro mutagenicity and cytotoxicity, and inhalation studies with rats, were used to evaluate different band characteristics added to cigarette paper. Although differences in the amount of band material was associated with an increase in some metals measured in mainstream tobacco smoke, it was not dose responsive to any band design parameter (base paper permeability, band width, band spacing, band chalk amount, or citrate). Occasional, minor differences were produced by the different types of bands; overall, there was no increased toxicity. Although there were increases and decreases in some mainstream smoke constituents, the in vitro and in vivo testing performed demonstrated that low-permeability bands on cigarettes do not modify the toxicity of smoke inhaled by smokers.

  16. Band gap evaluations of metal-inserted titania nanomaterials

    International Nuclear Information System (INIS)

    Bashir, Sajid; Liu, Jingbo; Zhang Hui; Sun Xuhui; Guo Jinghua

    2013-01-01

    The electronic and crystalline properties of iron-inserted titania (Fe x Ti 1−x O 2 ) nanoparticles were measured using synchrotron-based soft X-ray spectroscopy and high-temperature X-ray powder diffraction (HT-XRD). The data from X-ray absorption and emission spectroscopy were used to examine occupied and unoccupied densities of states for O 2p and Ti/Fe 3d hybrid orbital characteristics. It was found that Fe 3+ insertion resulted in an up-shift of the band gap from 3.20 to 3.46 eV. This observation reflected site occupancy in the TiO 2 lattice by Fe dopant ions. From HT-XRD Rietveld analysis, Ti occupancy was found to be 0.92 and oxygen 1.00. In addition, the crystal structure remained anatase within a temperature range of 25–800 °C, while the lattice distortion increased due to thermal expansion.

  17. Using an Elastic Band Device After a Severe Obstetric Pubic Symphyseal Separation: Clinical and Imaging Evaluation.

    Science.gov (United States)

    Lasbleiz, Jeremy; Sevestre, François-Xavier; Moquet, Pierre-Yves

    2017-09-01

    Severe separation of the pubic symphysis is a rare delivery complication. Facing this pathology, we decided to study a new elastic band device. To evaluate the elastic band device, clinical (pain-rated) and imaging (magnetic resonance imaging and radiography) evaluations with and without the device were performed. The elastic band device is a European Conformity-certified medical device, which is made of neoprene straps, that reduces the mobility of the pelvis and the use of the internal rotator muscles. Once the elastic band device was in place, on postpartum day 1, radiography showed a decrease of the pubic width from 41 to 12 mm. Furthermore, pain decreased from 10 of 10 to 2 of 10 in 2 days, allowing the patient to ambulate and avoid surgery. After 1 month, the pubic width (6 mm) and anatomy were recovered but minor pain was still present with hip rotatory movements. The elastic band device was worn 24 hours a day from postpartum days 1-90 and 12 hours a day from postpartum days 90 to 150; afterward, the patient returned to normal life without the elastic band device. Use of an elastic band device was associated with a reduction of the pubic width and pain associated after obstetric pubic symphysis separation.

  18. Colour evaluation in scars: tristimulus colorimeter, narrow-band simple reflectance meter or subjective evaluation?

    Science.gov (United States)

    Draaijers, Lieneke J; Tempelman, Fenike R H; Botman, Yvonne A M; Kreis, Robert W; Middelkoop, Esther; van Zuijlen, Paul P M

    2004-03-01

    The evaluation of scar colour is, at present, usually limited to an assessment according to a scar assessment scale. Although useful, these assessment scales only evaluate subjectively the degree of scar colour. In this study, the reliability of the subjective assessment of scar colour by observers is compared to the reliability of the measurements of two objective colour measurement instruments. Four independent observers subjectively assessed the vascularisation and pigmentation of 49 scar areas in 20 patients. The degree of vascularisation and pigmentation was scored according to a scale ranging from '1', when it appeared to be like healthy skin, to '10', which corresponds to the worst imaginable outcome of vascularisation or pigmentation. The observers also scored the pigmentation categories of the scar (hypopigmention, hyperpigmention or mixed pigmentation). Finally, each observer measured the scar areas with a tristimulus colorimeter (Minolta Chromameter) and a narrow-band simple reflectance meter (DermaSpectrometer). A single observer could reliably carry out measurements of the DermaSpectrometer and the Minolta Chromameter for the evaluation of scar colour (r = 0.72). The vascularisation of scars could also be assessed reliably with a single observer (r = 0.76) whereas for a reliable assessment of pigmentation at least three observers were necessary (r > or = 0.77). The agreement between the observers for the pigmentation categories also turned out to be unacceptably low (k = 0.349). This study shows that an overall evaluation of scar colour with the DermaSpectrometer and the Minolta Chromameter is more reliable than the evaluation of scar colour with observers. Of both instruments for measuring scar colour, we prefer, because of its feasibility, the DermaSpectrometer.

  19. DATA QUALITY EVALUATION AND APPLICATION POTENTIAL ANALYSIS OF TIANGONG-2 WIDE-BAND IMAGING SPECTROMETER

    Directory of Open Access Journals (Sweden)

    B. Qin

    2018-04-01

    Full Text Available Tiangong-2 is the first space laboratory in China, which launched in September 15, 2016. Wide-band Imaging Spectrometer is a medium resolution multispectral imager on Tiangong-2. In this paper, the authors introduced the indexes and parameters of Wideband Imaging Spectrometer, and made an objective evaluation about the data quality of Wide-band Imaging Spectrometer in radiation quality, image sharpness and information content, and compared the data quality evaluation results with that of Landsat-8. Although the data quality of Wide-band Imager Spectrometer has a certain disparity with Landsat-8 OLI data in terms of signal to noise ratio, clarity and entropy. Compared with OLI, Wide-band Imager Spectrometer has more bands, narrower bandwidth and wider swath, which make it a useful remote sensing data source in classification and identification of large and medium scale ground objects. In the future, Wide-band Imaging Spectrometer data will be widely applied in land cover classification, ecological environment assessment, marine and coastal zone monitoring, crop identification and classification, and other related areas.

  20. Data Quality Evaluation and Application Potential Analysis of TIANGONG-2 Wide-Band Imaging Spectrometer

    Science.gov (United States)

    Qin, B.; Li, L.; Li, S.

    2018-04-01

    Tiangong-2 is the first space laboratory in China, which launched in September 15, 2016. Wide-band Imaging Spectrometer is a medium resolution multispectral imager on Tiangong-2. In this paper, the authors introduced the indexes and parameters of Wideband Imaging Spectrometer, and made an objective evaluation about the data quality of Wide-band Imaging Spectrometer in radiation quality, image sharpness and information content, and compared the data quality evaluation results with that of Landsat-8. Although the data quality of Wide-band Imager Spectrometer has a certain disparity with Landsat-8 OLI data in terms of signal to noise ratio, clarity and entropy. Compared with OLI, Wide-band Imager Spectrometer has more bands, narrower bandwidth and wider swath, which make it a useful remote sensing data source in classification and identification of large and medium scale ground objects. In the future, Wide-band Imaging Spectrometer data will be widely applied in land cover classification, ecological environment assessment, marine and coastal zone monitoring, crop identification and classification, and other related areas.

  1. Performance evaluation of the short-time objective intelligibility measure with different band importance functions

    DEFF Research Database (Denmark)

    Heidemann Andersen, Asger; de Haan, Jan Mark; Tan, Zheng-Hua

    performance measures: root-mean-squared-error, Pearson correlation, and Kendall rank correlation. The results show substantially improved performance when fitting and evaluating on the same dataset. However, this advantage does not necessarily subsist when fitting and evaluating on different datasets. When...... with a filter bank, 2) envelopes are extracted from each band, 3) the temporal correlation between clean and degraded envelopes is computed in short time segments, and 4) the correlation is averaged across time and frequency bands to obtain the final output. An unusual choice in the design of the STOI measure...

  2. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    International Nuclear Information System (INIS)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-01-01

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control,’ ‘hazard,’ ‘exposure,’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended

  3. Can Control Banding be Useful for the Safe Handling of Nanomaterials? A Systematic Review

    Science.gov (United States)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-01-01

    Objectives Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” Methods A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control’, ‘hazard’, ‘exposure’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the Methodological Index for Non-Randomized Studies (MINORS). The quality of the evidence was evaluated using Grading of Recommendations Assessment, Development and Evaluation (GRADE). Results A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these

  4. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    Science.gov (United States)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-06-01

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question "can control banding be useful to ensure adequate controls for the safe handling of nanomaterials." A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included `control,' `hazard,' `exposure,' and `risk' banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended exposure controls using

  5. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Eastlake, Adrienne, E-mail: aeastlake@cdc.gov [National Institute for Occupational Safety and Health, Nanotechnology Research Center (United States); Zumwalde, Ralph [RCS Corporation (United States); Geraci, Charles [National Institute for Occupational Safety and Health, Nanotechnology Research Center (United States)

    2016-06-15

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control,’ ‘hazard,’ ‘exposure,’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended

  6. Efficient evaluation of epitaxial MoS2 on sapphire by direct band structure imaging

    Science.gov (United States)

    Kim, Hokwon; Dumcenco, Dumitru; Fregnaux, Mathieu; Benayad, Anass; Kung, Yen-Cheng; Kis, Andras; Renault, Olivier; Lanes Group, Epfl Team; Leti, Cea Team

    The electronic band structure evaluation of two-dimensional metal dichalcogenides is critical as the band structure can be greatly influenced by the film thickness, strain, and substrate. Here, we performed a direct measurement of the band structure of as-grown monolayer MoS2 on single crystalline sapphire by reciprocal-space photoelectron emission microscopy with a conventional laboratory ultra-violet He I light source. Arrays of gold electrodes were deposited onto the sample in order to avoid charging effects due to the insulating substrate. This allowed the high resolution mapping (ΔE = 0.2 eV Δk = 0.05 Å-1) of the valence states in momentum space down to 7 eV below the Fermi level. The high degree of the epitaxial alignment of the single crystalline MoS2 nuclei was verified by the direct momentum space imaging over a large area containing multiple nuclei. The derived values of the hole effective mass were 2.41 +/-0.05 m0 and 0.81 +/-0.05 m0, respectively at Γ and K points, consistent with the theoretical values of the freestanding monolayer MoS2 reported in the literature. HK acknowledges the french CEA Basic Technological Research program (RTB) for funding.

  7. Radiometric Evaluation of SNPP VIIRS Band M11 via Sub-Kilometer Intercomparison with Aqua MODIS Band 7 over Snowy Scenes

    Directory of Open Access Journals (Sweden)

    Mike Chu

    2018-03-01

    Full Text Available A refined intersensor comparison study is carried out to evaluate the radiometric stability of the 2257 nm channel (M11 of the first Visible Infrared Imaging Radiometer Suite (VIIRS aboard the Suomi National Polar-orbiting Partnership (SNPP satellite. This study is initiated as part of the examination into the performance of key shortwave infrared (SWIR bands for SNPP VIIRS ocean color data processing and applications, with Band M11 playing key role over turbid and inland waters. The evaluation utilizes simultaneous nadir overpasses (SNOs to compare SNPP VIIRS Band M11 against Band 7 of the MODerate-resolution Imaging Spectroradiometer (MODIS in the Aqua satellite over concurrently observed scenes. The standard result of the radiance comparison is a seemingly uncontrolled and inconsistent time series unsuitable for further analyses, in great contrast to other matching band-pairs whose radiometric comparisons are typically stable around 1.0 within 1% variation. The mismatching relative spectral response (RSR between the two respective bands, with SNPP VIIRS M11 at 2225 to 2275 nm and Aqua MODIS B7 at 2125 to 2175 nm, is demonstrated to be the cause of the large variation because of the different dependence of the spectral responses of the two bands over identical scenes. A consistent radiometric comparison time series, however, can be extracted from SNO events that occur over snowy surfaces. A customized selection and analysis procedure successfully identifies the snowy scenes within the SNO events and builds a stable comparison time series. Particularly instrumental for the success of the comparison is the use of the half-kilometer spatial resolution data of Aqua MODIS B7 that significantly enhances the statistics. The final refined time series of Aqua MODIS B7 radiance over the SNPP VIIRS M11 radiance is stable at around 0.39 within 2.5% showing no evidence of drift. The radiometric ratio near 0.39 suggests the strong presence of medium

  8. Evaluation of a 433 MHz Band Body Sensor Network for Biomedical Applications

    Science.gov (United States)

    Kim, Saim; Brendle, Christian; Lee, Hyun-Young; Walter, Marian; Gloeggler, Sigrid; Krueger, Stefan; Leonhardt, Steffen

    2013-01-01

    Body sensor networks (BSN) are an important research topic due to various advantages over conventional measurement equipment. One main advantage is the feasibility to deploy a BSN system for 24/7 health monitoring applications. The requirements for such an application are miniaturization of the network nodes and the use of wireless data transmission technologies to ensure wearability and ease of use. Therefore, the reliability of such a system depends on the quality of the wireless data transmission. At present, most BSNs use ZigBee or other IEEE 802.15.4 based transmission technologies. Here, we evaluated the performance of a wireless transmission system of a novel BSN for biomedical applications in the 433 MHz ISM band, called Integrated Posture and Activity NEtwork by Medit Aachen (IPANEMA) BSN. The 433 MHz ISM band is used mostly by implanted sensors and thus allows easy integration of such into the BSN. Multiple measurement scenarios have been assessed, including varying antenna orientations, transmission distances and the number of network participants. The mean packet loss rate (PLR) was 0.63% for a single slave, which is comparable to IEEE 802.15.4 BSNs in the proximity of Bluetooth or WiFi networks. Secondly, an enhanced version is evaluated during on-body measurements with five slaves. The mean PLR results show a comparable good performance for measurements on a treadmill (2.5%), an outdoor track (3.4%) and in a climate chamber (1.5%). PMID:23344383

  9. Evaluation of error bands and confidence limits for thermal measurements in the CFTL bundle

    International Nuclear Information System (INIS)

    Childs, K.W.; Sanders, J.P.; Conklin, J.C.

    1979-01-01

    Surface cladding temperatures for the fuel rod simulators in the Core Flow Test Loop (CFTL) must be inferred from a measurement at a thermocouple junction within the rod. This step requires the evaluation of the thermal field within the rod based on known parameters such as heat generation rate, dimensional tolerances, thermal properties, and contact coefficients. Uncertainties in the surface temperature can be evaluated by assigning error bands to each of the parameters used in the calculation. A statistical method has been employed to establish the confidence limits for the surface temperature from a combination of the standard deviations of the important parameters. This method indicates that for a CFTL fuel rod simulator with a total power of 38 kW and a ratio of maximum to average axial power of 1.21, the 95% confidence limit for the calculated surface temperature is +- 45 0 C at the midpoint of the rod

  10. 2-GHz band man-made noise evaluation for cryogenic receiver front-end

    Energy Technology Data Exchange (ETDEWEB)

    Narahashi, S; Satoh, K; Suzuki, Y [Research Laboratories, NTT DoCoMo, Inc., 3-5 Hikari-no-oka, Yokosuka, Kanagawa 239-8536 (Japan); Mimura, T [Intellectual Property Department, NTT DoCoMo, Inc., 2-11-1 Nagatacho, Chiyoda, Tokyo 100-6150 (Japan); Nojima, T [Graduate School of Information Science and Technology, Hokkaido University, Nishi 9, Kita 14, Kita, Sapporo 060-0808 (Japan)], E-mail: narahashi@nttdocomo.co.jp

    2008-02-01

    This paper presents measured results of man-made noise in urban and suburban areas in the 2-GHz band with amplitude probability distribution (APD) in order to evaluate the impact of man-made noise on an experimental cryogenic receiver front-end (CRFE). The CRFE comprises a high-temperature superconducting filter, cryogenically-cooled low-noise amplifier, and highly reliable cryostat that is very compact. The CRFE is anticipated to be an effective way to achieve efficient frequency utilization and to improve the sensitivity of mobile base station receivers. It is important to measure the characteristics of the man-made noise in typical cellular base station antenna environments and confirm their impact on the CRFE reception with APD because if man-made noise has a stronger effect than thermal noise, the CRFE would fail to offer any improvement in sensitivity. The measured results suggest that the contribution of man-made noise in the 2-GHz band can be ignored as far as the wideband code division multiple access (W-CDMA) system is concerned.

  11. A Study of Criteria for the Evaluation of Secondary School Instrumentalists When Auditioning for Festival Bands. Final Report.

    Science.gov (United States)

    Owen, Curtis D., Jr.

    This study purposed to develop a means of evaluating student performance in auditions for festival bands which would minimize the inconsistencies of subjective judgment. Tape recordings of student auditions were played three times to judges. During the first audition, evaluators rated students on a continuum scale with numerical divisions, and…

  12. VIIRS Reflective Solar Band Radiometric and Stability Evaluation Using Deep Convective Clouds

    Science.gov (United States)

    Chang, Tiejun; Xiong, Xiaoxiong; Mu, Qiaozhen

    2016-01-01

    This work takes advantage of the stable distribution of deep convective cloud (DCC) reflectance measurements to assess the calibration stability and detector difference in Visible Infrared Imaging Radiometer Suite (VIIRS) reflective bands. VIIRS Sensor Data Records (SDRs) from February 2012 to June 2015 are utilized to analyze the long-term trending, detector difference, and half angle mirror (HAM) side difference. VIIRS has two thermal emissive bands with coverage crossing 11 microns for DCC pixel identification. The comparison of the results of these two processing bands is one of the indicators of analysis reliability. The long-term stability analysis shows downward trends (up to approximately 0.4 per year) for the visible and near-infrared bands and upward trends (up to 0.5per year) for the short- and mid-wave infrared bands. The detector difference for each band is calculated as the difference relative to the average reflectance overall detectors. Except for the slightly greater than 1 difference in the two bands at 1610 nm, the detector difference is less than1 for other solar reflective bands. The detector differences show increasing trends for some short-wave bands with center wavelengths from 400 to 600 nm and remain unchanged for the bands with longer center wavelengths. The HAM side difference is insignificant and stable. Those short-wave bands from 400 to 600 nm also have relatively larger HAM side difference, up to 0.25.Comparing the striped images from SDR and the smooth images after the correction validates the analyses of detector difference and HAM side difference. These analyses are very helpful for VIIRS calibration improvement and thus enhance product quality

  13. Evaluation of two "integrated" polarimetric Quantitative Precipitation Estimation (QPE) algorithms at C-band

    Science.gov (United States)

    Tabary, Pierre; Boumahmoud, Abdel-Amin; Andrieu, Hervé; Thompson, Robert J.; Illingworth, Anthony J.; Le Bouar, Erwan; Testud, Jacques

    2011-08-01

    SummaryTwo so-called "integrated" polarimetric rate estimation techniques, ZPHI ( Testud et al., 2000) and ZZDR ( Illingworth and Thompson, 2005), are evaluated using 12 episodes of the year 2005 observed by the French C-band operational Trappes radar, located near Paris. The term "integrated" means that the concentration parameter of the drop size distribution is assumed to be constant over some area and the algorithms retrieve it using the polarimetric variables in that area. The evaluation is carried out in ideal conditions (no partial beam blocking, no ground-clutter contamination, no bright band contamination, a posteriori calibration of the radar variables ZH and ZDR) using hourly rain gauges located at distances less than 60 km from the radar. Also included in the comparison, for the sake of benchmarking, is a conventional Z = 282 R1.66 estimator, with and without attenuation correction and with and without adjustment by rain gauges as currently done operationally at Météo France. Under those ideal conditions, the two polarimetric algorithms, which rely solely on radar data, appear to perform as well if not better, pending on the measurements conditions (attenuation, rain rates, …), than the conventional algorithms, even when the latter take into account rain gauges through the adjustment scheme. ZZDR with attenuation correction is the best estimator for hourly rain gauge accumulations lower than 5 mm h -1 and ZPHI is the best one above that threshold. A perturbation analysis has been conducted to assess the sensitivity of the various estimators with respect to biases on ZH and ZDR, taking into account the typical accuracy and stability that can be reasonably achieved with modern operational radars these days (1 dB on ZH and 0.2 dB on ZDR). A +1 dB positive bias on ZH (radar too hot) results in a +14% overestimation of the rain rate with the conventional estimator used in this study (Z = 282R1.66), a -19% underestimation with ZPHI and a +23

  14. Fading Evaluation in the 60 GHz Band in Line-of-Sight Conditions

    Directory of Open Access Journals (Sweden)

    J. Reig

    2014-01-01

    Full Text Available An exhaustive analysis of the small-scale fading amplitude in the 60 GHz band is addressed for line-of-sight conditions (LOS. From a measurement campaign carried out in a laboratory, we have estimated the distribution of the small-scale fading amplitude over a bandwidth of 9 GHz. From the measured data, we have estimated the parameters of the Rayleigh, Rice, Nakagami-m, Weibull, and α-μ distributions for the small-scale amplitudes. The test of Kolmogorov-Smirnov (K-S for each frequency bin is used to evaluate the performance of such statistical distributions. Moreover, the distributions of the main estimated parameters for such distributions are calculated and approximated for lognormal statistics in some cases. The matching of the above distributions to the experimental distribution has also been analyzed for the lower tail of the cumulative distribution function (CDF. These parameters offer information about the narrowband channel behavior that is useful for a better knowledge of the propagation characteristics at 60 GHz.

  15. Evaluation of optical localization in the visible band for ultrasound guidance in radiotherapy using a robotic arm

    NARCIS (Netherlands)

    Camps, S.M.; Costa, M.; Stevens, E.; Sanches, P.G.; Paiva Fonesca, G.; Bellezzo, M.; Verhaegen, F.

    2017-01-01

    In many medical fields, spatial localization of devices is of paramount importance to e.g. deliver treatments correctly or to perform accurate diagnostic evaluations. Among the different technologies available, optical localization in the visible band of the spectrum offers many advantages: minimum

  16. Control Banding and Nanotechnology Synergist

    Energy Technology Data Exchange (ETDEWEB)

    Zalk, D; Paik, S

    2009-12-15

    The average Industrial Hygienist (IH) loves a challenge, right? Okay, well here is one with more than a few twists. We start by going through the basics of a risk assessment. You have some chemical agents, a few workers, and the makings of your basic exposure characterization. However, you have no occupational exposure limit (OEL), essentially no toxicological basis, and no epidemiology. Now the real handicap is that you cannot use sampling pumps, cassettes, tubes, or any of the media in your toolbox, and the whole concept of mass-to-dose is out the window, even at high exposure levels. Of course, by the title, you knew we were talking about nanomaterials (NM). However, we wonder how many IHs know that this topic takes everything you know about your profession and turns it upside down. It takes the very foundations that you worked so hard in college and in the field to master and pulls it out from underneath you. It even takes the gold standard of our profession, the quantitative science of exposure assessment, and makes it look pretty darn rusty. Now with NM there is the potential to get some aspect of quantitative measurements, but the instruments are generally very expensive and getting an appropriate workplace personal exposure measurement can be very difficult if not impossible. The potential for workers getting exposures, however, is very real, as evidenced by a recent publication reporting worker exposures to polyacrylate nanoparticles in a Chinese factory (Song et al. 2009). With something this complex and challenging, how does a concept as simple as Control Banding (CB) save the day? Although many IHs have heard of CB, most of their knowledge comes from its application in the COSHH Essentials toolkit. While there is conflicting published research on COSHH Essentials and its value for risk assessments, almost all of the experts agree that it can be useful when no OELs are available (Zalk and Nelson 2008). It is this aspect of CB, its utility with

  17. Evaluation of VIIRS and MODIS Thermal Emissive Band Calibration Stability Using Ground Target

    Directory of Open Access Journals (Sweden)

    Sriharsha Madhavan

    2016-02-01

    Full Text Available The S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS instrument, a polar orbiting Earth remote sensing instrument built using a strong MODIS background, employs a similarly designed on-board calibrating source—a V-grooved blackbody for the Thermal Emissive Bands (TEB. The central wavelengths of most VIIRS TEBs are very close to those of MODIS with the exception of the 10.7 µm channel. To ensure the long term continuity of climate data records derived using VIIRS and MODIS TEB, it is necessary to assess any systematic differences between the two instruments, including scenes with temperatures significantly lower than blackbody operating temperatures at approximately 290 K. Previous work performed by the MODIS Characterization Support Team (MCST at NASA/GSFC used the frequent observations of the Dome Concordia site located in Antarctica to evaluate the calibration stability and consistency of Terra and Aqua MODIS over the mission lifetime. The near-surface temperature measurements from an automatic weather station (AWS provide a direct reference useful for tracking the stability and determining the relative bias between the two MODIS instruments. In this study, the same technique is applied to the VIIRS TEB and the results are compared with those from the matched MODIS TEB. The results of this study show a small negative bias when comparing the matching VIIRS and Aqua MODIS TEB, implying a higher brightness temperature for S-VIIRS at the cold end. Statistically no significant drift is observed for VIIRS TEB performance over the first 3.5 years of the mission.

  18. Acoustic transfer function of cavity and its application to rapid evaluation of sound field at low frequency band

    Institute of Scientific and Technical Information of China (English)

    YIN Gang; CHEN Hualing; HU Xuanli; HUANG Xieqing

    2001-01-01

    A new method to obtain numerical solution of Acoustic Transfer Function (ATF) by BEM is presented. For a simply supported panel backed by a rectangular cavity at low frequency band (0-200 Hz), the frequency property of ATF is analyzed. The relation between the accuracy of the rapid evaluation of sound field and the discretization schemes of the vibrational panel is discussed. The result shows that the method to obtain ATF and the rapid evaluation of sound field using the ATF is suitable to low frequency band. If an appropriate discretization scheme is choosed based on the frequency involved and the effort to obtain ATF, the accuracy of the rapid evaluation of sound field is acceptable.

  19. The biomechanical evaluation of polyester as a tension band for the internal fixation of patellar fractures.

    LENUS (Irish Health Repository)

    McGreal, G

    2012-02-03

    We use a braided polyester suture in place of cerclage wire in tension band fixations. The objective of this study was to test the biomechanical properties of this technique. Sixteen cadaveric patellae were fractured and repaired by modified tension band fixation. Eight were fixed using eighteen gauge stainless steel wire as a tension band and eight using braided polyester. All specimens were subjected to tensile testing. Polyester was 75.0% as strong as wire. For dynamic testing, the patellae of seven cadaveric knees were fractured and then fixed with polyester tension bands. These were mounted in a device capable of extending the knees from 90 degrees to neutral against an applied force. None of the fixations failed. Three of the specimens fixed using 18 gauge stainless steel wire were compared with three fixed using polyester over 2000 cycles of knee flexion and extension. Polyester performed as well as wire. We conclude that polyester is an acceptable alternative to wire in tension band fixation.

  20. Evaluation of Spectrum Usage for GSM band in Indoor and Outdoor Scenario for Dynamic Spectrum Access

    DEFF Research Database (Denmark)

    Patil, Kishor P.; Barge, Snehal; Skouby, Knud Erik

    2013-01-01

    , and transmit power. Several measurements have shown that the current spectrum is inefficiently utilized. The inefficient utilization problem can be solved with the help of Dynamic Spectrum Access. This paper describes the GSM band measurement conducted at different locations. In this paper, we report detailed...... measurement results of GSM band including statistical as well as spectral occupancy details obtained from measurement campaign conducted in Pune, India for indoor and outdoor scenarios. The results can be further used as an input for spectrum regulator for considering Cognitive Radio (CR) operation in GSM...

  1. Evaluation and Performance Analysis of 3D Printing Technique for Ka-Band Antenna Production

    DEFF Research Database (Denmark)

    Armendariz, Unai; Rommel, Simon; Rodríguez Páez, Juan Sebastián

    2016-01-01

    This paper presents the design and fabrication of 3D printed WR-28 waveguide horn antennas operating in the Ka-band frequency range between 26.5GHz and 40GHz. Three antennas are fabricated from polylactide acid filaments in conductive and non-conductive variants; the latter is covered...

  2. Four-Tap RF Canceller Evaluation for Indoor In-Band Full-Duplex Wireless Operation

    Science.gov (United States)

    2016-07-24

    I. INTRODUCTION In-band full-duplex (IBFD) wireless operation can help alleviate the frequency spectrum congestion issues faced by current system...Valkama, “Wideband self-adaptive rf cancellation circuit for full- duplex radio: Operating principle and measurements,” in 2015 IEEE 81st Vehicular

  3. Design and evaluation of noise suppression sheet for GHz band utilizing magneto-elastic effect

    Science.gov (United States)

    Igarashi, Toshiyuki; Kondo, Koichi; Yoshida, Shigeyoshi

    2017-12-01

    Feasibility of realizing a noise suppression sheet (NSS) coping with the low SHF band such as the 5 GHz band was investigated, which was composed of soft magnetic metal flakes dispersed in a polymer. For suppressing noises, the higher frequency one of the bimodal frequency dispersion (lower frequency one: Dispersion DII, higher frequency one: Dispersion DIII) seen in the imaginary permeability (μ″; magnetic loss component) spectrum of the NSS was aimed to utilize. Referring to the previous finding that Dispersion DIII is originated from a magneto-elastic effect, several magnetic composite sheets were prepared using various alloy flakes with different saturation magnetostriction (λs), and their frequency (fr(DIII)) and magnitude (μ″(DIII)) of Dispersion DIII were investigated. It was found that the NSS containing flakes with higher λs exhibited higher fr(DIII) and higher μ″(DIII)/μ″(DII), which was ratio of μ″(DIII) to the magnitude of Dispersion DII (μ″(DII)). The fr(DIII) for the NSS having the highest λs containing Fe-Co alloy flake reached 7.45 GHz and μ″ in the 5 GHz band was approximately twice as high as the conventional NSS containing Fe-Si-Al alloy flake. For transmission attenuation power ratio (Rtp) when an NSS was placed on a microstrip line with characteristic impedance of 50 Ω, NSS with larger fr(DIII)2 · μ″(DIII) ∝ Ms2 (Ms: saturation magnetization), which theoretically gave the frequency limit of imaginary permeability for a thin film, exhibited larger Rtp in the low SHF band. These results suggested that an NSS containing a magnetic flake material with both large λs and Ms was suitable for suppressing low SHF band noises.

  4. Evaluation of the JPL X-band 32 element active array. [for deep space communication

    Science.gov (United States)

    Boreham, J. F.; Postal, R. B.; Conroy, B. L.

    1979-01-01

    Tests performed on an X-band 32-element active array are described. Antenna pattern characteristics of the array were tested in its standard operating mode as well as several degraded performance modes, including failures of 1, 2, 3, 4, 8, 16, and 31 elements. Additionally, the array was characterized with the addition of a metallic shroud, and also characterized versus rf drive level and at a single off-axis electronic beamsteered position. Characterization was performed on several of the 3/4-watt, three-stage, X-band solid-state power amplifier modules. The characterization included swept amplitude response, amplitude and phase versus temperature from -20 to +60 C, and intermodulation distortion of selected modules. The array is described and conclusions and recommendations based upon the experience and results achieved are included.

  5. Evaluation and Analysis of a Multi-Band Transceiver for Next Generation Telemetry Applications

    Science.gov (United States)

    2014-06-01

    UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Morgan State University (INC) 1700 E Cold Spring LN, Baltimore MD 21251-0002 8...Eng., Samuel Berhanu, and Willie L. Thompson II, D.Eng Morgan State University , The Clarence M. Mitchell Jr. School of Engineering Center of... DDC ) BAND SELECTION Kintex FPGA DIGITAL RADIO RECEIVER DIGITAL RADIO TRANSMITTER ADC Fs < 225 MSPS Fs = 400 MHz RF BW = 36 MHz FREQ TRANSLATION VIA

  6. High Peak Power Test and Evaluation of S-band Waveguide Switches

    Science.gov (United States)

    Nassiri, A.; Grelick, A.; Kustom, R. L.; White, M.

    1997-05-01

    The injector and source of particles for the Advanced Photon Source is a 2856-MHz S-band electron-positron linear accelerator (linac) which produces electrons with energies up to 650 MeV or positrons with energies up to 450 MeV. To improve the linac rf system availability, an additional modulator-klystron subsystem is being constructed to provide a switchable hot spare unit for each of the five exsisting S-band transmitters. The switching of the transmitters will require the use of SF6-pressurized S-band waveguide switches at a peak operating power of 35 MW. Such rf switches have been successfully operated at other accelerator facilities but at lower peak powers. A test stand has been set up at the Stanford Linear Accelerator Center (SLAC) Klystron Factory to conduct tests comparing the power handling characteristics of two WR-284 and one WR-340 switches. Test results are presented and their implications for the design of the switching system are discussed.

  7. X-band ESR study on evaluation of radicals induced in pasteurized pepper

    International Nuclear Information System (INIS)

    Matsuura, Masaaki; Ogawa, Satoko; Ukai, Mitsuko; Oowada, Shigeru

    2007-01-01

    The radical properties of pasteurized pepper were investigated by means of X-band ESR spectroscopy. Pasteurization process was done by irradiation or steam. There were three radicals in the specimens before and after pasteurization. Upon irradiation a new radical was found. ESR peak intensity of specimen before and after parturition with steam was almost same level. Peak intensity of radiated pepper showed almost 4 times as compare with that of non treated pepper. Radical activity of the specimens after pasteurization showed almost same value. We concluded that radicals were induced by irradiation. But the radical activity was not changed before and after pasteurization. (author)

  8. Specific or nonspecific? Evaluation of band, baseline, and cognitive specificity of sensorimotor rhythm- and gamma-based neurofeedback.

    Science.gov (United States)

    Kober, Silvia Erika; Witte, Matthias; Neuper, Christa; Wood, Guilherme

    2017-10-01

    Neurofeedback (NF) is often criticized because of the lack of empirical evidence of its specificity. Our present study thus focused on the specificity of NF on three levels: band specificity, cognitive specificity, and baseline specificity. Ten healthy middle-aged individuals performed ten sessions of SMR (sensorimotor rhythm, 12-15Hz) NF training. A second group (N=10) received feedback of a narrow gamma band (40-43Hz). Effects of NF on EEG resting measurements (tonic EEG) and cognitive functions (memory, intelligence) were evaluated using a pre-post design. Both training groups were able to linearly increase the target training frequencies (either SMR or gamma), indicating the trainability of these EEG frequencies. Both NF training protocols led to nonspecific changes in other frequency bands during NF training. While SMR NF only led to concomitant changes in slower frequencies, gamma training affected nearly the whole power spectrum. SMR NF specifically improved memory functions. Gamma training showed only marginal effects on cognitive functions. SMR power assessed during resting measurements significantly increased after SMR NF training compared to a pre-assessment, indicating specific effects of SMR NF on baseline/tonic EEG. The gamma group did not show any pre-post changes in their EEG resting activity. In conclusion, SMR NF specifically affects cognitive functions (cognitive specificity) and tonic EEG (baseline specificity), while increasing SMR during NF training nonspecifically affects slower EEG frequencies as well (band non-specificity). Gamma NF was associated with nonspecific effects on the EEG power spectrum during training, which did not lead to considerable changes in cognitive functions or baseline EEG activity. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Band-limited Green's Functions for Quantitative Evaluation of Acoustic Emission Using the Finite Element Method

    Science.gov (United States)

    Leser, William P.; Yuan, Fuh-Gwo; Leser, William P.

    2013-01-01

    A method of numerically estimating dynamic Green's functions using the finite element method is proposed. These Green's functions are accurate in a limited frequency range dependent on the mesh size used to generate them. This range can often match or exceed the frequency sensitivity of the traditional acoustic emission sensors. An algorithm is also developed to characterize an acoustic emission source by obtaining information about its strength and temporal dependence. This information can then be used to reproduce the source in a finite element model for further analysis. Numerical examples are presented that demonstrate the ability of the band-limited Green's functions approach to determine the moment tensor coefficients of several reference signals to within seven percent, as well as accurately reproduce the source-time function.

  10. Evaluating the More Suitable ISM Frequency Band for IoT-Based Smart Grids: A Quantitative Study of 915 MHz vs. 2400 MHz.

    Science.gov (United States)

    Sandoval, Ruben M; Garcia-Sanchez, Antonio-Javier; Garcia-Sanchez, Felipe; Garcia-Haro, Joan

    2016-12-31

    IoT has begun to be employed pervasively in industrial environments and critical infrastructures thanks to its positive impact on performance and efficiency. Among these environments, the Smart Grid (SG) excels as the perfect host for this technology, mainly due to its potential to become the motor of the rest of electrically-dependent infrastructures. To make this SG-oriented IoT cost-effective, most deployments employ unlicensed ISM bands, specifically the 2400 MHz one, due to its extended communication bandwidth in comparison with lower bands. This band has been extensively used for years by Wireless Sensor Networks (WSN) and Mobile Ad-hoc Networks (MANET), from which the IoT technologically inherits. However, this work questions and evaluates the suitability of such a "default" communication band in SG environments, compared with the 915 MHz ISM band. A comprehensive quantitative comparison of these bands has been accomplished in terms of: power consumption, average network delay, and packet reception rate. To allow such a study, a dual-band propagation model specifically designed for the SG has been derived, tested, and incorporated into the well-known TOSSIM simulator. Simulation results reveal that only in the absence of other 2400 MHz interfering devices (such as WiFi or Bluetooth) or in small networks, is the 2400 MHz band the best option. In any other case, SG-oriented IoT quantitatively perform better if operating in the 915 MHz band.

  11. Evaluating the More Suitable ISM Frequency Band for IoT-Based Smart Grids: A Quantitative Study of 915 MHz vs. 2400 MHz

    Directory of Open Access Journals (Sweden)

    Ruben M. Sandoval

    2016-12-01

    Full Text Available IoT has begun to be employed pervasively in industrial environments and critical infrastructures thanks to its positive impact on performance and efficiency. Among these environments, the Smart Grid (SG excels as the perfect host for this technology, mainly due to its potential to become the motor of the rest of electrically-dependent infrastructures. To make this SG-oriented IoT cost-effective, most deployments employ unlicensed ISM bands, specifically the 2400 MHz one, due to its extended communication bandwidth in comparison with lower bands. This band has been extensively used for years by Wireless Sensor Networks (WSN and Mobile Ad-hoc Networks (MANET, from which the IoT technologically inherits. However, this work questions and evaluates the suitability of such a “default” communication band in SG environments, compared with the 915 MHz ISM band. A comprehensive quantitative comparison of these bands has been accomplished in terms of: power consumption, average network delay, and packet reception rate. To allow such a study, a dual-band propagation model specifically designed for the SG has been derived, tested, and incorporated into the well-known TOSSIM simulator. Simulation results reveal that only in the absence of other 2400 MHz interfering devices (such as WiFi or Bluetooth or in small networks, is the 2400 MHz band the best option. In any other case, SG-oriented IoT quantitatively perform better if operating in the 915 MHz band.

  12. Evaluation of dual polarization scattering matrix radar rain backscatter measurements in the X- and Q-bands

    Science.gov (United States)

    Agrawal, A. P.; Carnegie, D. W.; Boerner, W.-M.

    This paper presents an evaluation of polarimetric rain backscatter measurements collected with coherent dual polarization radar systems in the X (8.9 GHz) and Q (45GHz) bands, the first being operated in a pulsed mode and the second being a FM-CW system. The polarimetric measurement data consisted for each band of fifty files of time-sequential scattering matrix measurements expressed in terms of a linear (H, V) antenna polarization state basis. The rain backscattering takes place in a rain cell defined by the beam widths and down range distances of 275 ft through 325 ft and the scattering matrices were measured far below the hydrometeoric scattering center decorrelation time so that ensemble averaging of time-sequential scattering matrices may be applied. In the data evaluation great care was taken in determining: (1) polarimetric Doppler velocities associated with the motion of descending oscillating raindrops and/or eddies within the moving swaths of coastal rain showers, and (2) also the properties of the associated co/cross-polarization rain clutter nulls and their distributions on the Poincare polarization sphere.

  13. EVALUATION OF AIRBORNE L- BAND MULTI-BASELINE POL-INSAR FOR DEM EXTRACTION BENEATH FOREST CANOPY

    Directory of Open Access Journals (Sweden)

    W. M. Li

    2018-04-01

    Full Text Available DEM beneath forest canopy is difficult to extract with optical stereo pairs, InSAR and Pol-InSAR techniques. Tomographic SAR (TomoSAR based on different penetration and view angles could reflect vertical structure and ground structure. This paper aims at evaluating the possibility of TomoSAR for underlying DEM extraction. Airborne L-band repeat-pass Pol-InSAR collected in BioSAR 2008 campaign was applied to reconstruct the 3D structure of forest. And sum of kronecker product and algebraic synthesis algorithm were used to extract ground structure, and phase linking algorithm was applied to estimate ground phase. Then Goldstein cut-branch approach was used to unwrap the phases and then estimated underlying DEM. The average difference between the extracted underlying DEM and Lidar DEM is about 3.39 m in our test site. And the result indicates that it is possible for underlying DEM estimation with airborne L-band repeat-pass TomoSAR technique.

  14. Evaluation of Airborne l- Band Multi-Baseline Pol-Insar for dem Extraction Beneath Forest Canopy

    Science.gov (United States)

    Li, W. M.; Chen, E. X.; Li, Z. Y.; Jiang, C.; Jia, Y.

    2018-04-01

    DEM beneath forest canopy is difficult to extract with optical stereo pairs, InSAR and Pol-InSAR techniques. Tomographic SAR (TomoSAR) based on different penetration and view angles could reflect vertical structure and ground structure. This paper aims at evaluating the possibility of TomoSAR for underlying DEM extraction. Airborne L-band repeat-pass Pol-InSAR collected in BioSAR 2008 campaign was applied to reconstruct the 3D structure of forest. And sum of kronecker product and algebraic synthesis algorithm were used to extract ground structure, and phase linking algorithm was applied to estimate ground phase. Then Goldstein cut-branch approach was used to unwrap the phases and then estimated underlying DEM. The average difference between the extracted underlying DEM and Lidar DEM is about 3.39 m in our test site. And the result indicates that it is possible for underlying DEM estimation with airborne L-band repeat-pass TomoSAR technique.

  15. The TRICLOBS Dynamic Multi-Band Image Data Set for the Development and Evaluation of Image Fusion Methods.

    Directory of Open Access Journals (Sweden)

    Alexander Toet

    Full Text Available The fusion and enhancement of multiband nighttime imagery for surveillance and navigation has been the subject of extensive research for over two decades. Despite the ongoing efforts in this area there is still only a small number of static multiband test images available for the development and evaluation of new image fusion and enhancement methods. Moreover, dynamic multiband imagery is also currently lacking. To fill this gap we present the TRICLOBS dynamic multi-band image data set containing sixteen registered visual (0.4-0.7μm, near-infrared (NIR, 0.7-1.0μm and long-wave infrared (LWIR, 8-14μm motion sequences. They represent different military and civilian surveillance scenarios registered in three different scenes. Scenes include (military and civilian people that are stationary, walking or running, or carrying various objects. Vehicles, foliage, and buildings or other man-made structures are also included in the scenes. This data set is primarily intended for the development and evaluation of image fusion, enhancement and color mapping algorithms for short-range surveillance applications. The imagery was collected during several field trials with our newly developed TRICLOBS (TRI-band Color Low-light OBServation all-day all-weather surveillance system. This system registers a scene in the Visual, NIR and LWIR part of the electromagnetic spectrum using three optically aligned sensors (two digital image intensifiers and an uncooled long-wave infrared microbolometer. The three sensor signals are mapped to three individual RGB color channels, digitized, and stored as uncompressed RGB (false color frames. The TRICLOBS data set enables the development and evaluation of (both static and dynamic image fusion, enhancement and color mapping algorithms. To allow the development of realistic color remapping procedures, the data set also contains color photographs of each of the three scenes. The color statistics derived from these photographs

  16. Evaluation of X-band polarimetric radar estimation of rainfall and rain drop size distribution parameters in West Africa

    Science.gov (United States)

    Koffi, A. K.; Gosset, M.; Zahiri, E.-P.; Ochou, A. D.; Kacou, M.; Cazenave, F.; Assamoi, P.

    2014-06-01

    As part of the African Monsoon Multidisciplinary Analysis (AMMA) field campaign an X-band dual-polarization Doppler radar was deployed in Benin, West-Africa, in 2006 and 2007, together with a reinforced rain gauge network and several optical disdrometers. Based on this data set, a comparative study of several rainfall estimators that use X-band polarimetric radar data is presented. In tropical convective systems as encountered in Benin, microwave attenuation by rain is significant and quantitative precipitation estimation (QPE) at X-band is a challenge. Here, several algorithms based on the combined use of reflectivity, differential reflectivity and differential phase shift are evaluated against rain gauges and disdrometers. Four rainfall estimators were tested on twelve rainy events: the use of attenuation corrected reflectivity only (estimator R(ZH)), the use of the specific phase shift only R(KDP), the combination of specific phase shift and differential reflectivity R(KDP,ZDR) and an estimator that uses three radar parameters R(ZH,ZDR,KDP). The coefficients of the power law relationships between rain rate and radar variables were adjusted either based on disdrometer data and simulation, or on radar-gauges observations. The three polarimetric based algorithms with coefficients predetermined on observations outperform the R(ZH) estimator for rain rates above 10 mm/h which explain most of the rainfall in the studied region. For the highest rain rates (above 30 mm/h) R(KDP) shows even better scores, and given its performances and its simplicity of implementation, is recommended. The radar based retrieval of two parameters of the rain drop size distribution, the normalized intercept parameter NW and the volumetric median diameter Dm was evaluated on four rainy days thanks to disdrometers. The frequency distributions of the two parameters retrieved by the radar are very close to those observed with the disdrometer. NW retrieval based on a combination of ZH

  17. EVALUATION OF PRIMARY PROPHYLAXIS WITH PROPRANOLOL AND ELASTIC BAND LIGATION IN VARICEAL BLEEDING IN CIRRHOTIC CHILDREN AND ADOLESCENTS

    Directory of Open Access Journals (Sweden)

    Júlio Rocha PIMENTA

    Full Text Available ABSTRACT Background The efficacy of nonselective β-blocker and endoscopic procedures, such as endoscopic variceal ligation, as primary prophylaxis of variceal hemorrhage in cirrhotic adults was demonstrated by numerous controlled trials, but in pediatric population, few are the number of studies. Objective The objective of this study is to evaluate the primary prophylaxis with β-blocker in cirrhotic children and adolescents with portal hypertension. Methods This is a cohort study encompassing 26 cirrhotic patients. β-blocker prophylaxis was performed with propranolol. When contraindicated the use of β-blocker, or if side effects presents, the patients were referred to endoscopic therapy with band ligation. Patients were evaluated by endoscopy, and those who had varicose veins of medium and large caliber or reddish spots, regardless of the caliber of varices, received primary prophylaxis. Results Of the 26 patients evaluated, 9 (34.6% had contraindications to the use of propranolol and were referred for endoscopic prophylaxis. Six (35.3% of the 17 patients who received β-blocker (propranolol, had bled after a median follow-up time of 1.9 years. β-blockage dosage varied from 1 mg/kg/day to 3.1 mg/kg/day and seven (41.2% patients had the propranolol suspended due to fail of the β-blockage or adverse effects, such as drowsiness, bronchospasm and hypotension. Patients who received endoscopic prophylaxis (elastic bandage had no bleeding during the follow-up period. Conclusion All of the patients that had upper gastroinstestinal bleeding in this study were under propranolol prophylaxis. The use of propranolol showed a high number of contraindications and side effects, requiring referral to endoscopic prophylaxis. The endoscopic prophylaxis was effective in reducing episodes of bleeding.

  18. On the use of the residue theorem for the efficient evaluation of band-averaged input power into linear second-order dynamic systems

    Science.gov (United States)

    D'Amico, R.; Koo, K.; Huybrechs, D.; Desmet, W.

    2013-12-01

    An alternative to numerical quadrature is proposed to compute the power injected into a vibrating structure over a certain frequency band. Instead of evaluating the system response at several sampling frequencies within the considered band, the integral is computed by estimating the residue at a few complex frequencies, corresponding to the poles of the weighting function. This technique provides considerable benefits in terms of computation time, since the integration is independent of the width of the frequency band. Two application examples show the effectiveness of the approach. Firstly, the use of a Butterworth filter instead of a rectangular weighting function is assessed. Secondly, the accuracy of the approximation in case of hysteretic damping is proven. Finally, the computational performance of the technique is compared with classical numerical quadrature schemes.

  19. ′Metal to resin′: A comparative evaluation of conventional band and loop space maintainer with the fiber reinforced composite resin space maintainer in children

    Directory of Open Access Journals (Sweden)

    A Garg

    2014-01-01

    Full Text Available Aims: To compare the clinical efficacy of two space maintainers namely, conventional band and loop and Fiber Reinforced Composite Resin (FRCR space maintainers . Subjects and Methods: Thirty healthy children, aged 5 to 8 years were selected having at least two deciduous molars in different quadrants indicated for extraction or lost previously. FRCR space maintainer was placed in one quadrant and in the other quadrant band and loop space maintainer was cemented. All the patients were recalled at 1 st , 3 rd , and 6 th months for evaluation of both types of space maintainer. Patient acceptability, time taken, and clinical efficacy was recorded. Statistical analysis used: The observations thus obtained were subjected to statistical analysis using Chi- square test and Mann-Whitney U test. Results: Patient acceptability was greater in Group I (FRCR in comparison to Group II (band and loop space maintainer. The time taken by Group I was significantly lower as compared to that of Group II. In Group I, debonding of enamel, composite was the most common complication leading to failure followed by debonding of fiber composite. In Group II, cement loss was the most common complication leading to failure followed by slippage of band and fracture of loop. The success rates of Groups I and Group II weares 63.3% and 36.7%, respectively. Conclusion: The study concluded that FRCRFiber Reinforced Composite Resin (Ribbond space maintainers can be considered as viable alternative to the conventional band and loop space maintainers.

  20. Structural, electronic structure, and band alignment properties at epitaxial NiO/Al{sub 2}O{sub 3} heterojunction evaluated from synchrotron based X-ray techniques

    Energy Technology Data Exchange (ETDEWEB)

    Singh, S. D., E-mail: devsh@rrcat.gov.in; Das, Arijeet; Ajimsha, R. S.; Upadhyay, Anuj; Kamparath, Rajiv; Mukherjee, C.; Misra, P.; Rai, S. K.; Sinha, A. K.; Ganguli, Tapas [Raja Ramanna Centre for Advanced Technology, Indore, Madhya Pradesh 452013 (India); Nand, Mangla; Jha, S. N. [Bhabha Atomic Research Centre, Mumbai, Maharashtra 400085 (India); Shukla, D. K.; Phase, D. M. [UGC-DAE Consortium for Scientific Research, Khandwa Road, Indore, Madhya Pradesh 452017 (India)

    2016-04-28

    The valence band offset value of 2.3 ± 0.2 eV at epitaxial NiO/Al{sub 2}O{sub 3} heterojunction is determined from photoelectron spectroscopy experiments. Pulsed laser deposited thin film of NiO on Al{sub 2}O{sub 3} substrate is epitaxially grown along [111] direction with two domain structures, which are in-plane rotated by 60° with respect to each other. Observation of Pendellosung oscillations around Bragg peak confirms high interfacial and crystalline quality of NiO layer deposited on Al{sub 2}O{sub 3} substrate. Surface related feature in Ni 2p{sub 3/2} core level spectra along with oxygen K-edge soft X-ray absorption spectroscopy results indicates that the initial growth of NiO on Al{sub 2}O{sub 3} substrate is in the form of islands, which merge to form NiO layer for the larger coverage. The value of conduction band offset is also evaluated from the measured values of band gaps of NiO and Al{sub 2}O{sub 3} layers. A type-I band alignment at NiO and Al{sub 2}O{sub 3} heterojunction is also obtained. The determined values of band offsets can be useful in heterojunction based light emitting devices.

  1. Evaluation of band alignment of α-Ga2O3/α-(Al x Ga1‑ x )2O3 heterostructures by X-ray photoelectron spectroscopy

    Science.gov (United States)

    Uchida, Takayuki; Jinno, Riena; Takemoto, Shu; Kaneko, Kentaro; Fujita, Shizuo

    2018-04-01

    The band alignment at an α-Ga2O3/α-(Al x Ga1‑ x )2O3 heterointerface, with different Al compositions (x), grown on a c-plane sapphire substrate was evaluated by X-ray photoelectron spectroscopy. The experimental results show that the heterointerface has the type-I band discontinuity with the valence band offsets of 0.090, 0.12, and 0.14 eV, and the conduction band offsets of 0.34, 0.79, and 1.87 eV, for x values of 0.1, 0.4, and 0.8, respectively. The small band offset for the valence band is attributed to the fact that the valence band of oxides is constituted by the localized O 2p level, which is dominated by the nature of oxygen atoms. The type-I band discontinuity is desirable for a variety of heterostructure devices.

  2. Noise exposure in marching bands

    Science.gov (United States)

    Keefe, Joseph

    2005-09-01

    Previous studies involving orchestras have shown that music ensembles can produce hazardous noise levels. There are no similar data for marching bands and pep bands. In order to evaluate the noise levels produced by marching and pep bands, 1/3-octave-band sound-pressure levels were measured while these groups rehearsed and performed. Data were collected while marching with the bands to ensure a realistic environment. Comparing these data to OSHA and NIOSH criteria, marching and pep band exposures often exceed safe values. For typical exposures, OSHA doses range from 11% to 295%, while NIOSH doses range from 35% to 3055%. Exposures that would be considered hazardous in the workplace are common in marching and pep bands; students and band directors should take steps to recognize the risk posed by various instruments and various locations, and should implement hearing conservation efforts.

  3. Evaluation of Empirical Ray-Tracing Model for an Urban Outdoor Scenario at 73 GHz E-Band

    DEFF Research Database (Denmark)

    Nguyen, Huan Cong; R. MacCartney Jr., George; Thomas, Timothy

    2014-01-01

    In the summer of 2013, a wideband propagation measurement campaign using rotating directional antennas at 73 GHz was conducted at the New York University (NYU) campus, in order to collect extensive field measurements for use in a millimeter wave (mmWave) E-band statistical channel model. While...

  4. Evaluating the Solar Slowly Varying Component at C-Band Using Dual- and Single-Polarization Weather Radars in Europe

    Directory of Open Access Journals (Sweden)

    M. Gabella

    2017-01-01

    Full Text Available Six C-band weather radars located in Europe (Finland, Netherlands, and Switzerland have been used to monitor the slowly varying solar emission, which is an oscillation with an amplitude of several decibels and a period of approximately 27 days. It is caused by the fact that the number of active regions that enhance the solar radio emission with respect to the quiet component, as seen from Earth, varies because of the Sun’s rotation about its axis. The analysis is based on solar signals contained in the polar volume data produced during the operational weather scan strategy. This paper presents hundreds of daily comparisons between radar estimates and the Sun’s reference signal, during the current active Sun period (year 2014. The Sun’s reference values are accurately measured by the Dominion Radio Astrophysical Observatory (DRAO at S-band and converted to C-band using a standard DRAO formula. Vertical and horizontal polarization receivers are able to capture the monthly oscillation of the solar microwave signal: the standard deviation of the log-transformed ratio between radars and the DRAO reference ranges from 0.26 to 0.4 dB. A larger coefficient (and a different value for the quiet Sun component in the standard formula improves the agreement.

  5. Evaluation of SAR in a human body model due to wireless power transmission in the 10 MHz band

    International Nuclear Information System (INIS)

    Laakso, Ilkka; Tsuchida, Shogo; Hirata, Akimasa; Kamimura, Yoshitsugu

    2012-01-01

    This study discusses a computational method for calculating the specific absorption rate (SAR) due to a wireless power transmission system in the 10 MHz frequency band. A two-step quasi-static method comprised of the method of moments and the scalar potential finite-difference method are proposed. The applicability of the quasi-static approximation for localized exposure in this frequency band is discussed by comparing the SAR in a lossy dielectric cylinder computed with a full-wave electromagnetic analysis and the quasi-static approximation. From the computational results, the input impedance of the resonant coils was affected by the existence of the cylinder. On the other hand, the magnetic field distribution in free space and considering the cylinder and an impedance matching circuit were in good agreement; the maximum difference in the amplitude of the magnetic field was 4.8%. For a cylinder–coil distance of 10 mm, the difference between the peak 10 g averaged SAR in the cylinder computed with the full-wave electromagnetic method and our quasi-static method was 7.8%. These results suggest that the quasi-static approach is applicable for conducting the dosimetry of wireless power transmission in the 10 MHz band. With our two-step quasi-static method, the SAR in the anatomically based model was computed for different exposure scenarios. From those computations, the allowable input power satisfying the limit of a peak 10 g averaged SAR of 2.0 W kg −1 was 830 W in the worst case exposure scenario with a coil positioned at a distance of 30 mm from the chest. (paper)

  6. Evaluation of SAR in a human body model due to wireless power transmission in the 10 MHz band.

    Science.gov (United States)

    Laakso, Ilkka; Tsuchida, Shogo; Hirata, Akimasa; Kamimura, Yoshitsugu

    2012-08-07

    This study discusses a computational method for calculating the specific absorption rate (SAR) due to a wireless power transmission system in the 10 MHz frequency band. A two-step quasi-static method comprised of the method of moments and the scalar potential finite-difference method are proposed. The applicability of the quasi-static approximation for localized exposure in this frequency band is discussed by comparing the SAR in a lossy dielectric cylinder computed with a full-wave electromagnetic analysis and the quasi-static approximation. From the computational results, the input impedance of the resonant coils was affected by the existence of the cylinder. On the other hand, the magnetic field distribution in free space and considering the cylinder and an impedance matching circuit were in good agreement; the maximum difference in the amplitude of the magnetic field was 4.8%. For a cylinder-coil distance of 10 mm, the difference between the peak 10 g averaged SAR in the cylinder computed with the full-wave electromagnetic method and our quasi-static method was 7.8%. These results suggest that the quasi-static approach is applicable for conducting the dosimetry of wireless power transmission in the 10 MHz band. With our two-step quasi-static method, the SAR in the anatomically based model was computed for different exposure scenarios. From those computations, the allowable input power satisfying the limit of a peak 10 g averaged SAR of 2.0 W kg(-1) was 830 W in the worst case exposure scenario with a coil positioned at a distance of 30 mm from the chest.

  7. Contrast-enhanced computed tomography angiography and volume-rendered imaging for evaluation of cellophane banding in a dog with extrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    H. Yoon

    2011-04-01

    Full Text Available A 4-year-old, 1.8 kg, male, castrated Maltese was presented for evaluation of urolithiasis. Urinary calculi were composed of ammonium biurate. Preprandial and postprandial bile acids were 44.2 and 187.3 μmol/ , respectively (reference ranges 0–10 and 0–20 μmol/ , respectively. Single-phase contrast-enhanced computed tomography angiography (CTA with volume-rendered imaging (VRI was obtained. VRI revealed a portocaval shunt originating just cranial to a tributary of the gastroduodenal vein and draining into the caudal vena cava at the level of the epiploic foramen. CTA revealed a 3.66 mm-diameter shunt measured at the level of the termination of the shunt and a 3.79 mm-diameter portal vein measured at the level between the origin of the shunt and the porta of the liver. Surgery was performed using cellophane banding without attenuation. Follow-up single-phase CTA with VRI was obtained 10 weeks after surgery. VRI revealed no evidence of portosystemic communication on the level of a cellophane band and caudal to the cellophane band. CTA demonstrated an increased portal vein diameter (3.79–5.27 mm measured at the level between the origin of the shunt and the porta of the liver. Preprandial and postprandial bile acids were 25 and 12.5 μmol/ , respectively (aforementioned respective reference ranges, 3 months post-surgery. No problems were evident at 6 months.

  8. C-Band Airport Surface Communications System Standards Development. Phase II Final Report. Volume 2: Test Bed Performance Evaluation and Final AeroMACS Recommendations

    Science.gov (United States)

    Hall, Edward; Magner, James

    2011-01-01

    This report is provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-Band and L-Band Communications Standard Development and was based on direction provided by FAA project-level agreements for New ATM Requirements-Future Communications. Task 7 included two subtasks. Subtask 7-1 addressed C-band (5091- to 5150-MHz) airport surface data communications standards development, systems engineering, test bed and prototype development, and tests and demonstrations to establish operational capability for the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2 focused on systems engineering and development support of the L-band digital aeronautical communications system (L-DACS). Subtask 7-1 consisted of two phases. Phase I included development of AeroMACS concepts of use, requirements, architecture, and initial high-level safety risk assessment. Phase II builds on Phase I results and is presented in two volumes. Volume I is devoted to concepts of use, system requirements, and architecture, including AeroMACS design considerations. Volume II (this document) describes an AeroMACS prototype evaluation and presents final AeroMACS recommendations. This report also describes airport categorization and channelization methodologies. The purposes of the airport categorization task were (1) to facilitate initial AeroMACS architecture designs and enable budgetary projections by creating a set of airport categories based on common airport characteristics and design objectives, and (2) to offer high-level guidance to potential AeroMACS technology and policy development sponsors and service providers. A channelization plan methodology was developed because a common global methodology is needed to assure seamless interoperability among diverse AeroMACS services potentially supplied by multiple service providers.

  9. Evaluation of elastic bands for lower extremity resistance training in adults with and without musculo-skeletal pain

    DEFF Research Database (Denmark)

    Sundstrup, E; Jakobsen, M D; Andersen, C H

    2014-01-01

    these findings. However, pain in the lower back decreased muscular activity of the gluteus maximus and vastus medialis (P resistance induce high levels of muscle activity in all the large muscle groups at the hip, knee, and back. Importantly, the efficiency of these exercises......Therapists commonly use elastic bands in resistance exercises during rehabilitation of smaller muscles, such as in the shoulder. However, the effectiveness has not yet been investigated for larger muscle groups. This study investigates muscle activity during lower extremity exercises....... Electromyographic (EMG) activity of 10 muscles was measured in 24 women and 18 men during lunges with elastic resistance, lunges with dumbbells, and unilateral leg press in machine using 10 repetition maximum loadings, and normalized to maximal voluntary isometric contraction EMG. Lunges with dumbbells and leg...

  10. An electromyographic evaluation of elastic band exercises targeting neck and shoulder pain among helm bearing military helicopter crew

    DEFF Research Database (Denmark)

    Kristensen, Lars Askær; Grøndberg, Thomas Stig; Murray, Mike

    INTRODUCTION Flight related neck and shoulder pain is a frequent problem in helicopter pilots and crew [1]. Pain causes personnel suffering, reduces operational capabilities and incurs high financial cost due to the loss of manpower. Evidence suggests that the occupational loading such as posture...... adopted during flight and increased weight added to the mass of the head due to the helmet and night vision equipment contribute to the development of neck and shoulder pain. Strength training has among other occupational groups been found to reduce musculoskeletal pain [2]. A 20-week exercise program...... for the neck and shoulder muscles using elastic bands has been applied for helicopter pilots and crew in the Royal Danish Air Force to prevent and reduce pain. The exercise program had an initial loading of 20RM and was increased progressively towards 12RM in the final weeks. A muscle activity >60% MVE...

  11. Development and evaluation of automated systems for detection and classification of banded chromosomes: current status and future perspectives

    International Nuclear Information System (INIS)

    Wang Xingwei; Zheng Bin; Wood, Marc; Li Shibo; Chen Wei; Liu Hong

    2005-01-01

    Automated detection and classification of banded chromosomes may help clinicians diagnose cancers and other genetic disorders at an early stage more efficiently and accurately. However, developing such an automated system (including both a high-speed microscopic image scanning device and related computer-assisted schemes) is quite a challenging and difficult task. Since the 1980s, great research efforts have been made to develop fast and more reliable methods to assist clinical technicians in performing this important and time-consuming task. A number of computer-assisted methods including classical statistical methods, artificial neural networks and knowledge-based fuzzy logic systems, have been applied and tested. Based on the initial test using limited datasets, encouraging results in algorithm and system development have been demonstrated. Despite the significant research effort and progress made over the last two decades, computer-assisted chromosome detection and classification systems have not been routinely accepted and used in clinical laboratories. Further research and development is needed

  12. Development and evaluation of automated systems for detection and classification of banded chromosomes: current status and future perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Wang Xingwei [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, OK (United States); Zheng Bin [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Wood, Marc [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, OK (United States); Li Shibo [Department of Pediatrics, University of Oklahoma Medical Center, Oklahoma City, OK (United States); Chen Wei [Department of Physics and Engineering, University of Central Oklahoma, Edmond, OK (United States); Liu Hong [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, OK (United States)

    2005-08-07

    Automated detection and classification of banded chromosomes may help clinicians diagnose cancers and other genetic disorders at an early stage more efficiently and accurately. However, developing such an automated system (including both a high-speed microscopic image scanning device and related computer-assisted schemes) is quite a challenging and difficult task. Since the 1980s, great research efforts have been made to develop fast and more reliable methods to assist clinical technicians in performing this important and time-consuming task. A number of computer-assisted methods including classical statistical methods, artificial neural networks and knowledge-based fuzzy logic systems, have been applied and tested. Based on the initial test using limited datasets, encouraging results in algorithm and system development have been demonstrated. Despite the significant research effort and progress made over the last two decades, computer-assisted chromosome detection and classification systems have not been routinely accepted and used in clinical laboratories. Further research and development is needed.

  13. Mesotherapy for skin rejuvenation: assessment of the subepidermal low-echogenic band by ultrasound evaluation with cross-sectional B-mode scanning.

    Science.gov (United States)

    Lacarrubba, Francesco; Tedeschi, Aurora; Nardone, Beatrice; Micali, Giuseppe

    2008-01-01

    Skin-targeted ultrasound is a noninvasive technique that has been extensively used to evaluate age-related dermal changes, and the presence of a subepidermal low-echogenic band (SLEB) has been related to chronic UVR exposure in several studies. Since SLEB echogenicity is photoage-related, the aim of this study was to evaluate, through ultrasound imaging, the effects on skin photoaging of mesotherapy, a treatment approach currently used in cosmetic dermatology for skin rejuvenation. Twenty women (mean age: 46.7 range 40-60 years) with physical signs of moderate photoaging on the dorsum of the hands were enrolled and treated with multiple microinjections of hyaluronic acid (HA) salts of biotechnological origin (1.000 Kd) every week for 4 weeks. In all subjects, ultrasound evaluation was performed at each visit and 1 week after the last treatment to evaluate SLEB echogenicity changes during treatment. At the end of study, a statistically significant (p mesotherapy with HA may be an effective treatment for skin photoaging, as confirmed by ultrasound. Follow-up investigations on larger series of patients are necessary to further evaluate the safety, effectiveness, and duration of effect of this possible therapeutic approach to skin photoaging.

  14. Evaluating the virulence and longevity of non-woven fiber bands impregnated with Metarhizium anisopliae against the Asian longhorned beetle, Anoplophora glabripennis (Coleoptera: Cerambycidae)

    Science.gov (United States)

    Ryan P. Shanley; Melody Keena; Micheal M. Wheeler; Jarrod Leland; Ann E. Hajek

    2009-01-01

    Fiber bands impregnated with entomopathogenic fungi (=fungal bands) provide an effective method for controlling the invasive Asian longhorned beetle, Anoplophora glabripennis (Motschulsky) (Coleoptera: Cerambycidae). In this study we investigated the effective longevity of fungal bands for use against A. glabripennis, using...

  15. Structural analysis and evaluation of actual PC bridge using 950 keV/3.95 MeV X-band linacs

    Science.gov (United States)

    Takeuchi, H.; Yano, R.; Ozawa, I.; Mitsuya, Y.; Dobashi, K.; Uesaka, M.; Kusano, J.; Oshima, Y.; Ishida, M.

    2017-07-01

    In Japan, bridges constructed during the strong economic growth era are facing an aging problem and advanced maintenance methods have become strongly required recently. To meet this demand, we develop the on-site inspection system using 950 keV/3.95 MeV X-band (9.3 GHz) linac X-ray sources. These systems can visualize in seconds the inner states of bridges, including cracks of concrete, location and state of tendons (wires) and other imperfections. At the on-site inspections, 950 keV linac exhibited sufficient performance. But, for thicker concrete, it is difficult to visualize the internal state by 950 keV linac. Therefore, we proceeded the installation of 3.95 MeV linac for on-site bridge inspection. In addition, for accurate evaluation, verification on the parallel motion CT technique and FEM analysis are in progress.

  16. GPR signal enhancement using band-pass and K–L filtering: a case study for the evaluation of grout in a shielded tunnel

    International Nuclear Information System (INIS)

    Xie, Xiongyao; Zeng, Chenchao; Wang, Zhigao

    2013-01-01

    The rapidness, non-destructiveness and high precision of ground penetrating radar (GPR) technology has enabled it to be widely and increasingly used in tunnel detection. However, data acquisition was usually restricted by physical and many other limitations. In order to improve the signal-to-noise ratio, band-pass and Karhunen–Loève (K–L) filtering are recommended. An evaluation of Yingbin No. 3 Road Tunnel is presented to illustrate the effectiveness of GPR in the inspection of the thickness of the grouting layer behind the segment and the function of the two methods mentioned above. The advantages and limitations of these two processing methods are discussed in this paper and suggestions are provided. (paper)

  17. Usefulness of contrast-enhanced wide-band Doppler ultrasonograpy to diagnose alveolar echinococcosis of the liver and evaluate the effect of the treatment

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yasuaki; Fujimoto, Yoshinori E-mail: yfujimot@asahikawa-med.ac.jp; Hosoki, Yayoi; Suzuki, Masako; Inoue, Mitsutaka; Sakurai, Shinobu; Ohtake, Takaaki; Ohhira, Masumi; Saito, Hiroyuki; Kohgo, Yutaka

    2003-12-01

    Alveolar echinococcosis is a rare parasitic disease caused by Echinococcus multicularis and most commonly involves the liver. Early diagnosis and accurate evaluation of the effect of the treatment are essential to improve the prognosis of patients with alveolar echinococcosis of the liver (AEL). The aim of this study was to demonstrate the characteristic imaging of AEL by contrast-enhanced Dynamic Flow (CE-DF) employing a wide-band Doppler technique for the diagnosis and the accurate evaluation of the effect of the treatment. Four patients with five AEL lesions before treatment or during medication were examined by CE-DF. All of the five AEL lesions examined by CE-DF revealed a defect with an irregular and distinct margin like a worm-eaten defect appearance, which was never observed on other hepatic lesions, in liver perfusion image during post-vascular phase. In addition, CE-DF made it possible to measure the size of AEL lesions accurately because the margin was detected distinctly. These data suggest that CE-DF is clinically useful for the diagnosis of AEL and the evaluation of the effect of the treatment.

  18. Congenital Constriction Band Syndrome

    OpenAIRE

    Rajesh Gupta, Fareed Malik, Rishabh Gupta, M.A.Basit, Dara Singh

    2008-01-01

    Congenital constriction bands are anomalous bands that encircle a digit or an extremity. Congenitalconstriction band syndrome is rare condition and is mostly associated with other musculoskeletaldisorders.We report such a rare experience.

  19. Evaluation and optimization of the bandwidth of static converters: application to multi-cell converters; Evaluation et optimisation de la bande passante des convertisseurs statiques

    Energy Technology Data Exchange (ETDEWEB)

    Aime, M.

    2003-11-15

    Thanks to the technological progress achieved in the field of power electronics, the use of static converters has spread to new applications. In particular, some applications such as active filtering or the supply of special AC machines require power converters having good dynamic performances. The subject of this thesis is to evaluate systematically the dynamic performances of multi-cell converters, and then to optimize these performances. This document is organized in four chapters. The first one summarizes the main multilevel converter structures, and some control strategies dedicated to these structures. The second chapter presents the evaluation criteria chosen to quantify the dynamic performances of static converters. These criteria are then used to compare the performances obtained with two different PWM strategies. An optimized strategy which results from a trade-off between the two former strategies is then introduced. The third chapter shows a new control strategy of multi-cell voltage source converters. This new strategy enables to control the peak current at a fixed switching frequency. The operation of this controller is explained, and the results obtained by digital simulations are presented and discussed. The fourth chapter deals with the experimental achievement of the peak current control. In particular, the implementation of the control algorithm within a FPGA is demonstrated. Finally, the conclusion of this thesis presents some orientations for further developments, in order to improve the current control strategy and to widen its field of applications. (author)

  20. Band structure of semiconductors

    CERN Document Server

    Tsidilkovski, I M

    2013-01-01

    Band Structure of Semiconductors provides a review of the theoretical and experimental methods of investigating band structure and an analysis of the results of the developments in this field. The book presents the problems, methods, and applications in the study of band structure. Topics on the computational methods of band structure; band structures of important semiconducting materials; behavior of an electron in a perturbed periodic field; effective masses and g-factors for the most commonly encountered band structures; and the treatment of cyclotron resonance, Shubnikov-de Haas oscillatio

  1. L-band brightness temperature disaggregation for use with S-band and C-band radiometer data for WCOM

    Science.gov (United States)

    Yao, P.; Shi, J.; Zhao, T.; Cosh, M. H.; Bindlish, R.

    2017-12-01

    There are two passive microwave sensors onboard the Water Cycle Observation Mission (WCOM), which includes a synthetic aperture radiometer operating at L-S-C bands and a scanning microwave radiometer operating from C- to W-bands. It provides a unique opportunity to disaggregate L-band brightness temperature (soil moisture) with S-band C-bands radiometer data. In this study, passive-only downscaling methodologies are developed and evaluated. Based on the radiative transfer modeling, it was found that the TBs (brightness temperature) between the L-band and S-band exhibit a linear relationship, and there is an exponential relationship between L-band and C-band. We carried out the downscaling results by two methods: (1) downscaling with L-S-C band passive measurements with the same incidence angle from payload IMI; (2) downscaling with L-C band passive measurements with different incidence angle from payloads IMI and PMI. The downscaling method with L-S bands with the same incident angle was first evaluated using SMEX02 data. The RMSE are 2.69 K and 1.52 K for H and V polarization respectively. The downscaling method with L-C bands is developed with different incident angles using SMEX03 data. The RMSE are 2.97 K and 2.68 K for H and V polarization respectively. These results showed that high-resolution L-band brightness temperature and soil moisture products could be generated from the future WCOM passive-only observations.

  2. Prevalence of comorbidities and baseline characteristics of LAP-BAND AP® subjects in the Helping Evaluate Reduction in Obesity (HERO study.

    Directory of Open Access Journals (Sweden)

    Nancy Dreyer

    Full Text Available OBJECTIVE: To describe the baseline characteristics in patients who chose placement of a LAP-BAND AP® System (LBAP and participated in the Helping Evaluate Reduction in Obesity (HERO Study across regions. PATIENTS AND METHODS: HERO is a five-year, prospective, multicenter, international study of patients with LBAP placement between July 22, 2009 and January 31, 2011. In addition to baseline and peri-surgery clinical data, seven follow up visits are scheduled at 3, 6 and 12 months, and annually through year five. Data collection included family and medical history, clinical outcomes, laboratory data, health-related quality of life (HRQoL, productivity, healthcare resource utilization, and adverse events. RESULTS: LBAP were placed in 1106 enrolled patients; 56.6% from the US, 26.3% from Europe, 7.1% from Canada, and 10.0% from Australia. The majority were female (n = 877 (79.3% with a mean age of 43 years (s.d. = 11.4 and mean body mass index of 45.1 kg/m(2 (s.d. = 6.9. The most common comorbidities were hypertension (HTN (overall  = 42.9% and diabetes (overall 22.2%, with 27% from the US and 14% from Europe. Overall, less than 5% had a history of cardiovascular disease. The prevalence rates of HTN, diabetes and cardiovascular disease were significantly (p<0.001 higher in men than in women across all regions. Overall HRQoL also worsened with increasing BMI. CONCLUSIONS: The HERO study is the first large, multinational and long-term registry with the LBAP. This study will provide real-world outcomes data on LAGB that will help inform patient choice, clinician treatment strategies, and payer reimbursement decisions.

  3. Evaluating patterns of a white-band disease (WBD outbreak in Acropora palmata using spatial analysis: a comparison of transect and colony clustering.

    Directory of Open Access Journals (Sweden)

    Jennifer A Lentz

    Full Text Available BACKGROUND: Despite being one of the first documented, there is little known of the causative agent or environmental stressors that promote white-band disease (WBD, a major disease of Caribbean Acropora palmata. Likewise, there is little known about the spatiality of outbreaks. We examined the spatial patterns of WBD during a 2004 outbreak at Buck Island Reef National Monument in the US Virgin Islands. METHODOLOGY/PRINCIPAL FINDINGS: Ripley's K statistic was used to measure spatial dependence of WBD across scales. Localized clusters of WBD were identified using the DMAP spatial filtering technique. Statistics were calculated for colony- (number of A. palmata colonies with and without WBD within each transect and transect-level (presence/absence of WBD within transects data to evaluate differences in spatial patterns at each resolution of coral sampling. The Ripley's K plots suggest WBD does cluster within the study area, and approached statistical significance (p = 0.1 at spatial scales of 1100 m or less. Comparisons of DMAP results suggest the transect-level overestimated the prevalence and spatial extent of the outbreak. In contrast, more realistic prevalence estimates and spatial patterns were found by weighting each transect by the number of individual A. palmata colonies with and without WBD. CONCLUSIONS: As the search for causation continues, surveillance and proper documentation of the spatial patterns may inform etiology, and at the same time assist reef managers in allocating resources to tracking the disease. Our results indicate that the spatial scale of data collected can drastically affect the calculation of prevalence and spatial distribution of WBD outbreaks. Specifically, we illustrate that higher resolution sampling resulted in more realistic disease estimates. This should assist in selecting appropriate sampling designs for future outbreak investigations. The spatial techniques used here can be used to facilitate other

  4. Evaluating patterns of a white-band disease (WBD) outbreak in Acropora palmata using spatial analysis: a comparison of transect and colony clustering.

    Science.gov (United States)

    Lentz, Jennifer A; Blackburn, Jason K; Curtis, Andrew J

    2011-01-01

    Despite being one of the first documented, there is little known of the causative agent or environmental stressors that promote white-band disease (WBD), a major disease of Caribbean Acropora palmata. Likewise, there is little known about the spatiality of outbreaks. We examined the spatial patterns of WBD during a 2004 outbreak at Buck Island Reef National Monument in the US Virgin Islands. Ripley's K statistic was used to measure spatial dependence of WBD across scales. Localized clusters of WBD were identified using the DMAP spatial filtering technique. Statistics were calculated for colony- (number of A. palmata colonies with and without WBD within each transect) and transect-level (presence/absence of WBD within transects) data to evaluate differences in spatial patterns at each resolution of coral sampling. The Ripley's K plots suggest WBD does cluster within the study area, and approached statistical significance (p = 0.1) at spatial scales of 1100 m or less. Comparisons of DMAP results suggest the transect-level overestimated the prevalence and spatial extent of the outbreak. In contrast, more realistic prevalence estimates and spatial patterns were found by weighting each transect by the number of individual A. palmata colonies with and without WBD. As the search for causation continues, surveillance and proper documentation of the spatial patterns may inform etiology, and at the same time assist reef managers in allocating resources to tracking the disease. Our results indicate that the spatial scale of data collected can drastically affect the calculation of prevalence and spatial distribution of WBD outbreaks. Specifically, we illustrate that higher resolution sampling resulted in more realistic disease estimates. This should assist in selecting appropriate sampling designs for future outbreak investigations. The spatial techniques used here can be used to facilitate other coral disease studies, as well as, improve reef conservation and management.

  5. Evaluation of an e-learning system for diagnosis of gastric lesions using magnifying narrow-band imaging: a multicenter randomized controlled study.

    Science.gov (United States)

    Nakanishi, Hiroyoshi; Doyama, Hisashi; Ishikawa, Hideki; Uedo, Noriya; Gotoda, Takuji; Kato, Mototsugu; Nagao, Shigeaki; Nagami, Yasuaki; Aoyagi, Hiroyuki; Imagawa, Atsushi; Kodaira, Junichi; Mitsui, Shinya; Kobayashi, Nozomu; Muto, Manabu; Takatori, Hajime; Abe, Takashi; Tsujii, Masahiko; Watari, Jiro; Ishiyama, Shuhei; Oda, Ichiro; Ono, Hiroyuki; Kaneko, Kazuhiro; Yokoi, Chizu; Ueo, Tetsuya; Uchita, Kunihisa; Matsumoto, Kenshi; Kanesaka, Takashi; Morita, Yoshinori; Katsuki, Shinichi; Nishikawa, Jun; Inamura, Katsuhisa; Kinjo, Tetsu; Yamamoto, Katsumi; Yoshimura, Daisuke; Araki, Hiroshi; Kashida, Hiroshi; Hosokawa, Ayumu; Mori, Hirohito; Yamashita, Haruhiro; Motohashi, Osamu; Kobayashi, Kazuhiko; Hirayama, Michiaki; Kobayashi, Hiroyuki; Endo, Masaki; Yamano, Hiroo; Murakami, Kazunari; Koike, Tomoyuki; Hirasawa, Kingo; Miyaoka, Youichi; Hamamoto, Hidetaka; Hikichi, Takuto; Hanabata, Norihiro; Shimoda, Ryo; Hori, Shinichiro; Sato, Tadashi; Kodashima, Shinya; Okada, Hiroyuki; Mannami, Tomohiko; Yamamoto, Shojiro; Niwa, Yasumasa; Yashima, Kazuo; Tanabe, Satoshi; Satoh, Hiro; Sasaki, Fumisato; Yamazato, Tetsuro; Ikeda, Yoshiou; Nishisaki, Hogara; Nakagawa, Masahiro; Matsuda, Akio; Tamura, Fumio; Nishiyama, Hitoshi; Arita, Keiko; Kawasaki, Keisuke; Hoppo, Kazushige; Oka, Masashi; Ishihara, Shinichi; Mukasa, Michita; Minamino, Hiroaki; Yao, Kenshi

    2017-10-01

    Background and study aim  Magnifying narrow-band imaging (M-NBI) is useful for the accurate diagnosis of early gastric cancer (EGC). However, acquiring skill at M-NBI diagnosis takes substantial effort. An Internet-based e-learning system to teach endoscopic diagnosis of EGC using M-NBI has been developed. This study evaluated its effectiveness. Participants and methods  This study was designed as a multicenter randomized controlled trial. We recruited endoscopists as participants from all over Japan. After completing Test 1, which consisted of M-NBI images of 40 gastric lesions, participants were randomly assigned to the e-learning or non-e-learning groups. Only the e-learning group was allowed to access the e-learning system. After the e-learning period, both groups received Test 2. The analysis set was participants who scored e-learning group and 197 in the non-e-learning group). After the e-learning period, all 395 completed Test 2. The analysis sets were e-learning group: n = 184; and non-e-learning group: n = 184. The mean Test 1 score was 59.9 % for the e-learning group and 61.7 % for the non-e-learning group. The change in accuracy in Test 2 was significantly higher in the e-learning group than in the non-e-learning group (7.4 points vs. 0.14 points, respectively; P  e-learning system in improving practitioners' capabilities to diagnose EGC using M-NBI.Trial registered at University Hospital Medical Information Network Clinical Trials Registry (UMIN000008569). © Georg Thieme Verlag KG Stuttgart · New York.

  6. Evaluation of Hyperspectral Multi-Band Indices to Estimate Chlorophyll-A Concentration Using Field Spectral Measurements and Satellite Data in Dianshan Lake, China

    Directory of Open Access Journals (Sweden)

    Linna Li

    2013-04-01

    Full Text Available Chlorophyll-a (Chl-a concentration is considered as a key indicator of the eutrophic status of inland water bodies. Various algorithms have been developed for estimating Chl-a in order to improve the accuracy of predictive models. The objective of this study is to assess the potential of hyperspectral multi-band indices to estimate the Chl-a concentration in Dianshan Lake, which is the largest lake in Shanghai, an international metropolis of China. Based on field spectral measurements and in-situ Chl-a concentration collected on 7–8 September 2010, hyperspectral multi-band indices were calibrated to estimate the Chl-a concentration with optimal wavelengths selected by model tuning. A three-band index accounts for 87.36% (R2 = 0.8736 of the Chl-a variation. A four-band index, which adds a wavelength in the near infrared (NIR region, results in a higher R2 (0.8997 by removing the absorption and backscattering effects of suspended solids. To test the applicability of the proposed indices for routinely monitoring of Chl-a in inland lakes, simulated Hyperion and real HJ-1A satellite data were selected to estimate the Chl-a concentration. The results show that the explanatory powers of these satellite hyperspectral multi-band indices are relatively high with R2 = 0.8559, 0.8945, 0.7969, and 0.8241 for simulated Hyperion and real HJ-1A satellite data, respectively. All of the results provide strong evidence that hyperspectral multi-band indices are promising and applicable to estimate Chl-a in eutrophic inland lakes.

  7. The role of high-resolution endoscopy and narrow-band imaging in the evaluation of upper GI neoplasia in familial adenomatous polyposis

    NARCIS (Netherlands)

    Lopez-Ceron, Maria; van den Broek, Frank J. C.; Mathus-Vliegen, Elisabeth M.; Boparai, Karam S.; van Eeden, Susanne; Fockens, Paul; Dekker, Evelien

    2013-01-01

    The Spigelman classification stratifies cancer risk in familial adenomatous polyposis (FAP) patients with duodenal adenomatosis. High-resolution endoscopy (HRE) and narrow-band imaging (NBI) may identify lesions at high risk. To compare HRE and NBI for the detection of duodenal and gastric polyps

  8. Adhesives for fixed orthodontic bands.

    Science.gov (United States)

    Millett, Declan T; Glenny, Anne-Marie; Mattick, Rye Cr; Hickman, Joy; Mandall, Nicky A

    2016-10-25

    Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. It has been shown that the quality of treatment result obtained with fixed appliances is much better than with removable appliances. Fixed appliances are, therefore, favoured by most orthodontists for treatment. The success of a fixed orthodontic appliance depends on the metal attachments (brackets and bands) being attached securely to the teeth so that they do not become loose during treatment. Brackets are usually attached to the front and side teeth, whereas bands (metal rings that go round the teeth) are more commonly used on the back teeth (molars). A number of adhesives are available to attach bands to teeth and it is important to understand which group of adhesives bond most reliably, as well as reducing or preventing dental decay during the treatment period. To evaluate the effectiveness of the adhesives used to attach bands to teeth during fixed appliance treatment, in terms of:(1) how often the bands come off during treatment; and(2) whether they protect the banded teeth against decay during fixed appliance treatment. The following electronic databases were searched: Cochrane Oral Health's Trials Register (searched 2 June 2016), Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 5) in the Cochrane Library (searched 2 June 2016), MEDLINE Ovid (1946 to 2 June 2016) and EMBASE Ovid (1980 to 2 June 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised and controlled clinical trials (RCTs and CCTs) (including split-mouth studies) of adhesives used to attach orthodontic bands to molar teeth were selected. Patients with full arch fixed orthodontic appliance(s) who had bands attached to molars were included. All review authors

  9. Wide Band to ''Double Band'' upgrade

    International Nuclear Information System (INIS)

    Kasper, P.; Currier, R.; Garbincius, P.; Butler, J.

    1988-06-01

    The Wide Band beam currently uses electrons obtained from secondary photon conversions to produce the photon beam incident on the experimental targets. By transporting the positrons produced in these conversions as well as the electrons it is possible to almost double the number of photons delivered to the experiments per primary beam proton. 11 figs

  10. Office-based narrow band imaging-guided flexible laryngoscopy tissue sampling: A cost-effectiveness analysis evaluating its impact on Taiwanese health insurance program

    OpenAIRE

    Fang, Tuan-Jen; Li, Hsueh-Yu; Liao, Chun-Ta; Chiang, Hui-Chen; Chen, I-How

    2015-01-01

    Narrow band imaging (NBI)-guided flexible laryngoscopy tissue sampling for laryngopharyngeal lesions is a novel technique. Patients underwent the procedure in an office-based setting without being sedated, which is different from the conventional technique performed using direct laryngoscopy. Although the feasibility and effects of this procedure were established, its financial impact on the institution and Taiwanese National Health Insurance program was not determined. Methods: This is a ...

  11. Amniotic constriction bands

    Science.gov (United States)

    ... Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Amniotic band sequence URL of this page: //medlineplus.gov/ency/ ... birth. The baby should be delivered in a medical center that has specialists experienced in caring for babies ... or partial loss of function of a body part. Congenital bands affecting large parts of the body cause the ...

  12. Band parameters of phosphorene

    International Nuclear Information System (INIS)

    Lew Yan Voon, L C; Wang, J; Zhang, Y; Willatzen, M

    2015-01-01

    Phosphorene is a two-dimensional nanomaterial with a direct band-gap at the Brillouin zone center. In this paper, we present a recently derived effective-mass theory of the band structure in the presence of strain and electric field, based upon group theory. Band parameters for this theory are computed using a first-principles theory based upon the generalized-gradient approximation to the density-functional theory. These parameters and Hamiltonian will be useful for modeling physical properties of phosphorene. (paper)

  13. Infrared diffuse interstellar bands

    Science.gov (United States)

    Galazutdinov, G. A.; Lee, Jae-Joon; Han, Inwoo; Lee, Byeong-Cheol; Valyavin, G.; Krełowski, J.

    2017-05-01

    We present high-resolution (R ˜ 45 000) profiles of 14 diffuse interstellar bands in the ˜1.45 to ˜2.45 μm range based on spectra obtained with the Immersion Grating INfrared Spectrograph at the McDonald Observatory. The revised list of diffuse bands with accurately estimated rest wavelengths includes six new features. The diffuse band at 15 268.2 Å demonstrates a very symmetric profile shape and thus can serve as a reference for finding the 'interstellar correction' to the rest wavelength frame in the H range, which suffers from a lack of known atomic/molecular lines.

  14. Band parameters of phosphorene

    DEFF Research Database (Denmark)

    Lew Yan Voon, L. C.; Wang, J.; Zhang, Y.

    2015-01-01

    Phosphorene is a two-dimensional nanomaterial with a direct band-gap at the Brillouin zone center. In this paper, we present a recently derived effective-mass theory of the band structure in the presence of strain and electric field, based upon group theory. Band parameters for this theory...... are computed using a first-principles theory based upon the generalized-gradient approximation to the density-functional theory. These parameters and Hamiltonian will be useful for modeling physical properties of phosphorene....

  15. CSF oligoclonal banding - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100145.htm CSF oligoclonal banding - series—Normal anatomy To use the ... 5 out of 5 Overview The cerebrospinal fluid (CSF) serves to supply nutrients to the central nervous ...

  16. Decay of superdeformed bands

    International Nuclear Information System (INIS)

    Carpenter, M.P.; Khoo, T.L.; Lauritsen, T.

    1995-01-01

    One of the major challenges in the study of superdeformation is to directly connect the large number of superdeformed bands now known to the yrast states. In this way, excitation energies, spins and parities can be assigned to the levels in the second well which is essential to establish the collective and single-particle components of these bands. This paper will review some of the progress which has been made to understand the decay of superdeformed bands using the new arrays including the measurement of the total decay spectrum and the establishment of direct one-step decays from the superdeformed band to the yrast line in 194 Hg. 42 refs., 5 figs

  17. Laparoscopic gastric banding

    Science.gov (United States)

    ... eat by making you feel full after eating small amounts of food. After surgery, your doctor can adjust the band ... You will feel full after eating just a small amount of food. The food in the small upper pouch will ...

  18. Spectral band selection for classification of soil organic matter content

    Science.gov (United States)

    Henderson, Tracey L.; Szilagyi, Andrea; Baumgardner, Marion F.; Chen, Chih-Chien Thomas; Landgrebe, David A.

    1989-01-01

    This paper describes the spectral-band-selection (SBS) algorithm of Chen and Landgrebe (1987, 1988, and 1989) and uses the algorithm to classify the organic matter content in the earth's surface soil. The effectiveness of the algorithm was evaluated comparing the results of classification of the soil organic matter using SBS bands with those obtained using Landsat MSS bands and TM bands, showing that the algorithm was successful in finding important spectral bands for classification of organic matter content. Using the calculated bands, the probabilities of correct classification for climate-stratified data were found to range from 0.910 to 0.980.

  19. Dynamic gauge adjustment of high-resolution X-band radar data for convective rain storms: Model-based evaluation against measured combined sewer overflow

    DEFF Research Database (Denmark)

    Borup, Morten; Grum, Morten; Linde, Jens Jørgen

    2016-01-01

    estimates through a hydraulic urban drainage model. The model is built entirely from physical data, without any calibration, to avoid bias towards any specific type of rainfall estimate. The performance is assessed by comparing measured and modelled water levels at a weir downstream of a highly impermeable......Numerous studies have shown that radar rainfall estimates need to be adjusted against rain gauge measurements in order to be useful for hydrological modelling. In the current study we investigate if adjustment can improve radar rainfall estimates to the point where they can be used for modelling...... overflows from urban drainage systems, and we furthermore investigate the importance of the aggregation period of the adjustment scheme. This is done by continuously adjusting X-band radar data based on the previous 5–30 min of rain data recorded by multiple rain gauges and propagating the rainfall...

  20. Evaluation of 5G Modulation Candidates WCP-COQAM, GFDM-OQAM, and FBMC-OQAM in Low-Band Highly Dispersive Wireless Channels

    Directory of Open Access Journals (Sweden)

    Aitor Lizeaga

    2017-01-01

    Full Text Available We analyse some of the candidates for modulations for 5G: FBMC-OQAM, GFDM-OQAM, and WCP-COQAM. Unlike most of the related bibliographies, which are oriented to mobile communications, our research is focused on 5G in cognitive radio based industrial wireless communications. According to the ultrareliability and low-latency requirements of industrial communications, we simulate the aforementioned modulations in low-band transmissions (carrier frequencies below 6 GHz and a bandwidth narrower than 100 MHz through large indoor spaces and severe multipath channels that emulate industrial halls. Moreover, we give detailed information about WCP-COQAM and how the windowing affects the protection against multipath effect and reduces spectral efficiency compared to GFDM-OQAM. We also compare the aforementioned filtered multicarrier techniques and OFDM in terms of robustness against multipath channels, power spectral density, and spectral efficiency. Based on these results, we aim at providing an approximate idea about the suitability of 5G MCM candidates for industrial wireless communications based on CR.

  1. Dynamic gauge adjustment of high-resolution X-band radar data for convective rain storms: Model-based evaluation against measured combined sewer overflow

    Science.gov (United States)

    Borup, Morten; Grum, Morten; Linde, Jens Jørgen; Mikkelsen, Peter Steen

    2016-08-01

    Numerous studies have shown that radar rainfall estimates need to be adjusted against rain gauge measurements in order to be useful for hydrological modelling. In the current study we investigate if adjustment can improve radar rainfall estimates to the point where they can be used for modelling overflows from urban drainage systems, and we furthermore investigate the importance of the aggregation period of the adjustment scheme. This is done by continuously adjusting X-band radar data based on the previous 5-30 min of rain data recorded by multiple rain gauges and propagating the rainfall estimates through a hydraulic urban drainage model. The model is built entirely from physical data, without any calibration, to avoid bias towards any specific type of rainfall estimate. The performance is assessed by comparing measured and modelled water levels at a weir downstream of a highly impermeable, well defined, 64 ha urban catchment, for nine overflow generating rain events. The dynamically adjusted radar data perform best when the aggregation period is as small as 10-20 min, in which case it performs much better than static adjusted radar data and data from rain gauges situated 2-3 km away.

  2. Ultra wide band antennas

    CERN Document Server

    Begaud, Xavier

    2013-01-01

    Ultra Wide Band Technology (UWB) has reached a level of maturity that allows us to offer wireless links with either high or low data rates. These wireless links are frequently associated with a location capability for which ultimate accuracy varies with the inverse of the frequency bandwidth. Using time or frequency domain waveforms, they are currently the subject of international standards facilitating their commercial implementation. Drawing up a complete state of the art, Ultra Wide Band Antennas is aimed at students, engineers and researchers and presents a summary of internationally recog

  3. Office-based narrow band imaging-guided flexible laryngoscopy tissue sampling: A cost-effectiveness analysis evaluating its impact on Taiwanese health insurance program.

    Science.gov (United States)

    Fang, Tuan-Jen; Li, Hsueh-Yu; Liao, Chun-Ta; Chiang, Hui-Chen; Chen, I-How

    2015-07-01

    Narrow band imaging (NBI)-guided flexible laryngoscopy tissue sampling for laryngopharyngeal lesions is a novel technique. Patients underwent the procedure in an office-based setting without being sedated, which is different from the conventional technique performed using direct laryngoscopy. Although the feasibility and effects of this procedure were established, its financial impact on the institution and Taiwanese National Health Insurance program was not determined. This is a retrospective case-control study. From May 2010 to April 2011, 20 consecutive patients who underwent NBI flexible laryngoscopy tissue sampling were recruited. During the same period, another 20 age-, sex-, and lesion-matched cases were enrolled in the control group. The courses for procedures and financial status were analyzed and compared between groups. Office-based NBI flexible laryngoscopy tissue sampling procedure took 27 minutes to be completed, while 191 minutes were required for the conventional technique. Average reimbursement for each case was New Taiwan Dollar (NT$)1264 for patients undergoing office-based NBI flexible laryngoscopy tissue sampling, while NT$10,913 for those undergoing conventional direct laryngoscopy in the operation room (p institution suffered a loss of at least NT$690 when performing NBI flexible laryngoscopy tissue sampling. Office-based NBI flexible laryngoscopy tissue sampling is a cost-saving procedure for patients and the Taiwanese National Health Insurance program. It also saves the procedure time. However, the net financial loss for the institution and physician would limit its popularization unless reimbursement patterns are changed. Copyright © 2013. Published by Elsevier B.V.

  4. Thermoelectric power factor of La0.9M0.1FeO3 (M = Ca and Ba) system: Structural, band gap and electrical transport evaluations

    Science.gov (United States)

    Karthikeyan, N.; Kumar, R. Ramesh; Jaiganesh, G.; Sivakumar, K.

    2018-01-01

    The search for thermoelectric materials has been incredibly increased due to the increase in global energy demand. Hence the present work focus on preparation and characterization of thermal transport phenomena of pure and Ba/Ca substituted perovskite LaFeO3 orthoferrite system. The conventional solid state reaction technique is utilized for the preparation of LaFeO3 and La0.9M0.1FeO3 (M = Ca and Ba) compounds. Crystal structure analyses of the prepared samples are analyses using Rietveld refinement process which confirms the orthoferrite crystal structure of all the prepared compounds with induced distortion in position of atoms by the incorporation of substituent atoms. The electronic structure calculations are performed by VASP. As the LaFeO3 compound is a strongly energy correlated system, the Density Functional Theory (DFT) calculations are performed by DFT + U (Hubbard function) method. The computed band gap values are compared with the energy gap values calculated from UV-Vis spectral analysis. Electrical conductivity measurement and Arrhenius behavior for the temperature range of room temperature to 650 K are analyzed and the drift increase in conductivity with respect to temperature is due to the thermally activated mobility of charge carriers. Temperature dependent thermopower analysis is also examined using homemade seebeck coefficient measurement system. The calculation of thermoelectric power factor reveals that the Ba substituted LaFeO3 compound show highest power factor value of 3.73 μW/K2 cm at higher temperature and the superior power factor values observed in the Ba substituted compound determine the material's capability in power generating devices based on thermoelectric effect.

  5. Band-notched spiral antenna

    Science.gov (United States)

    Jeon, Jae; Chang, John

    2018-03-13

    A band-notched spiral antenna having one or more spiral arms extending from a radially inner end to a radially outer end for transmitting or receiving electromagnetic radiation over a frequency range, and one or more resonance structures positioned adjacent one or more segments of the spiral arm associated with a notch frequency band or bands of the frequency range so as to resonate and suppress the transmission or reception of electromagnetic radiation over said notch frequency band or bands.

  6. InfiniBand-Experiences at the Forschungszentrum Karlsruhe

    International Nuclear Information System (INIS)

    Schwickerath, Ulrich; Heiss, Andreas

    2006-01-01

    The Institute for Scientific Computing (IWR) at the Forschungszentrum Karlsruhe has been evaluating the InfiniBand [InfiniBand Trade Association, InfiniBand Architecture Specification, Release 1.0, October 24, 2000] technology since end of the year 2002. The performance of the interconnect has been tested on different platforms and architectures using MPI. Sequential file transfer performance was measured with the RFIO protocol running on native InfiniBand [Ulrich Schwickerath, Andreas Heiss, Nucl. Instr. and Meth. A 534 (2004) 130, http://www.fzk.de/infiniband], and a newly developed InfiniBand-enabled version of the XROOTD

  7. SHARPENDING OF THE VNIR AND SWIR BANDS OF THE WIDE BAND SPECTRAL IMAGER ONBOARD TIANGONG-II IMAGERY USING THE SELECTED BANDS

    Directory of Open Access Journals (Sweden)

    Q. Liu

    2018-04-01

    Full Text Available The Tiangong-II space lab was launched at the Jiuquan Satellite Launch Center of China on September 15, 2016. The Wide Band Spectral Imager (WBSI onboard the Tiangong-II has 14 visible and near-infrared (VNIR spectral bands covering the range from 403–990 nm and two shortwave infrared (SWIR bands covering the range from 1230–1250 nm and 1628–1652 nm respectively. In this paper the selected bands are proposed which aims at considering the closest spectral similarities between the VNIR with 100 m spatial resolution and SWIR bands with 200 m spatial resolution. The evaluation of Gram-Schmidt transform (GS sharpening techniques embedded in ENVI software is presented based on four types of the different low resolution pan band. The experimental results indicated that the VNIR band with higher CC value with the raw SWIR Band was selected, more texture information was injected the corresponding sharpened SWIR band image, and at that time another sharpened SWIR band image preserve the similar spectral and texture characteristics to the raw SWIR band image.

  8. The hierarchically organized splitting of chromosome bands into sub-bands analyzed by multicolor banding (MCB).

    Science.gov (United States)

    Lehrer, H; Weise, A; Michel, S; Starke, H; Mrasek, K; Heller, A; Kuechler, A; Claussen, U; Liehr, T

    2004-01-01

    To clarify the nature of chromosome sub-bands in more detail, the multicolor banding (MCB) probe-set for chromosome 5 was hybridized to normal metaphase spreads of GTG band levels at approximately 850, approximately 550, approximately 400 and approximately 300. It could be observed that as the chromosomes became shorter, more of the initial 39 MCB pseudo-colors disappeared, ending with 18 MCB pseudo-colored bands at the approximately 300-band level. The hierarchically organized splitting of bands into sub-bands was analyzed by comparing the disappearance or appearance of pseudo-color bands of the four different band levels. The regions to split first are telomere-near, centromere-near and in 5q23-->q31, followed by 5p15, 5p14, and all GTG dark bands in 5q apart from 5q12 and 5q32 and finalized by sub-band building in 5p15.2, 5q21.2-->q21.3, 5q23.1 and 5q34. The direction of band splitting towards the centromere or the telomere could be assigned to each band separately. Pseudo-colors assigned to GTG-light bands were resistant to band splitting. These observations are in concordance with the recently proposed concept of chromosome region-specific protein swelling. Copyright 2003 S. Karger AG, Basel

  9. Performance Evaluation of Wavelet-Coded OFDM on a 4.9 Gbps W-Band Radio-over-Fiber Link

    DEFF Research Database (Denmark)

    Cavalcante, Lucas Costa Pereira; Rommel, Simon; Dinis, Rui

    2017-01-01

    Future generation mobile communications running on mm-wave frequencies will require great robustness against frequency selective channels. In this work we evaluate the transmission performance of 4.9 Gbps Wavelet-Coded OFDM signals on a 10 km fiber plus 58 m wireless Radio-over-Fiber link using...... a mm-wave radio frequency carrier. The results show that a 2×128 Wavelet-Coded OFDM system achieves a bit-error rate of 1e-4 with nearly 2.5 dB less signal-to-noise ratio than a convolutional coded OFDM system with equivalent spectral efficiency for 8 GHz-wide signals with 512 sub-carriers on a carrier...

  10. High macro rubber band ligature

    Directory of Open Access Journals (Sweden)

    José A. Reis Neto

    2013-07-01

    Full Text Available Purpose: The goal of a rubber band ligature is to promote fibrosis of the submucosa with subsequent fixation of the anal epithelium to the underlying sphincter. Following this principle, a new technique of ligature was developed based on two aspects: 1. macro banding: to have a better fibrosis and fixation by banding a bigger volume of mucosa and 2. higher ligature: to have this fixation at the origin of the hemorrhoidal cushion displacement. Methods: 1634 patients with internal hemorrhoidal disease grade II or III were treated by the technique called high macro rubber band. There was no distinction as to age, gender or race. To perform this technique a new hemorrhoidal device was specially designed with a larger diameter and a bigger capacity for mucosal volume aspiration. It is recommended to utilize a longer and wider anoscope to obtain a better view of the anal canal, which will facilitate the injection of submucosa higher in the anal canal and the insertion of the rubber band device. The hemorrhoidal cushion must be banded higher in the anal canal (4 cm above the pectinate line. It is preferable to treat all the hemorrhoids in one single session (maximum of three areas banded. Results: The analysis was retrospective without any comparison with conventional banding. The period of evaluation extended from one to twelve years. The analysis of the results showed perianal edema in 1.6% of the patients, immediate tenesmus in 0.8%, intense pain (need for parenteral analgesia in 1.6%, urinary retention in 0.1% of the patients and a symptomatic recurrence rate of 4.2%. All patients with symptomatic recurrence were treated with a new session of macro rubber banding. None of the patients developed anal or rectal sepsis. Small post-ligature bleeding was observed only in 0.8% of the patients. Conclusions: The high macro rubber banding technique represents an alternative method for the treatment of hemorrhoidal disease grades II or III, with good

  11. Semiconductors bonds and bands

    CERN Document Server

    Ferry, David K

    2013-01-01

    As we settle into this second decade of the twenty-first century, it is evident that the advances in micro-electronics have truly revolutionized our day-to-day lifestyle. The technology is built upon semiconductors, materials in which the band gap has been engineered for special values suitable to the particular application. This book, written specifically for a one semester course for graduate students, provides a thorough understanding of the key solid state physics of semiconductors. It describes how quantum mechanics gives semiconductors unique properties that enabled the micro-electronics revolution, and sustain the ever-growing importance of this revolution.

  12. Polarimetric and diffractive evaluation of 3.74 micron pixel-size LCoS in the telecommunications C-band

    Science.gov (United States)

    Wang, Mi; Martínez, Francisco J.; Márquez, Andrés.; Ye, Yabin; Zong, Liangjia; Pascual, Inmaculada; Beléndez, Augusto

    2017-08-01

    Liquid-crystal on Silicon (LCoS) microdisplays are one of the competing technologies to implement wavelength selective switches (WSS) for optical telecommunications. Last generation LCoS, with more than 4 megapixels, have decreased pixel size to values smaller than 4 microns, what increases interpixel cross-talk effects such as fringing-field. We proceed with an experimental evaluation of a 3.74 micron pixel size parallel-aligned LCoS (PA-LCoS) device. At 1550 nm, for the first time we use time-average Stokes polarimetry to measure the retardance and its flicker magnitude as a function of voltage. We also verify the effect of the antireflection coating when we try to characterize the PA-LCoS out of the designed interval for the AR coating. Some preliminary results for the performance for binary gratings are also given, where the decrease of modulation range with the increase in spatial frequency is shown, together with some residual polarization effects.

  13. Degenerate band edge laser

    Science.gov (United States)

    Veysi, Mehdi; Othman, Mohamed A. K.; Figotin, Alexander; Capolino, Filippo

    2018-05-01

    We propose a class of lasers based on a fourth-order exceptional point of degeneracy (EPD) referred to as the degenerate band edge (DBE). EPDs have been found in parity-time-symmetric photonic structures that require loss and/or gain; here we show that the DBE is a different kind of EPD since it occurs in periodic structures that are lossless and gainless. Because of this property, a small level of gain is sufficient to induce single-frequency lasing based on a synchronous operation of four degenerate Floquet-Bloch eigenwaves. This lasing scheme constitutes a light-matter interaction mechanism that leads also to a unique scaling law of the laser threshold with the inverse of the fifth power of the laser-cavity length. The DBE laser has the lowest lasing threshold in comparison to a regular band edge laser and to a conventional laser in cavities with the same loaded quality (Q ) factor and length. In particular, even without mirror reflectors the DBE laser exhibits a lasing threshold which is an order of magnitude lower than that of a uniform cavity laser of the same length and with very high mirror reflectivity. Importantly, this novel DBE lasing regime enforces mode selectivity and coherent single-frequency operation even for pumping rates well beyond the lasing threshold, in contrast to the multifrequency nature of conventional uniform cavity lasers.

  14. A comparison of L-band and C-band rf guns as sources for inline-injection systems

    International Nuclear Information System (INIS)

    Gallardo, J.C.; Kirk, H.G.; Meyerer, T.

    1994-12-01

    We consider the beam dynamics associated with installing a BNL type 1 1/2 cell L-band or C-band rf gun before two TESLA L-band cryomodules. This system will deliver a 25 MeV electron beam with peak currents on the order of 100 A suitable for further magnetic compression. evaluate the injection systems utilizing the electron beam dynamic code PARMELA from the point of view of minimizing the transverse invariant emittance

  15. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  16. Electronic band structure

    International Nuclear Information System (INIS)

    Grosso, G.

    1986-01-01

    The aim of this chapter is to present, in detail, some theoretical methods used to calculate electronic band structures in crystals. The basic strategies employed to attack the problem of electronic-structure calculations are presented. Successive sections present the basic formulations of the tight-binding, orthogonalized-plane-wave, Green'sfunction, and pseudopotential methods with a discussion of their application to perfect solids. Exemplifications in the case of a few selected problems provide further insight by the author into the physical aspects of the different methods and are a guide to the use of their mathematical techniques. A discussion is offered of completely a priori Hartree-Fock calculations and attempts to extend them. Special aspects of the different methods are also discussed in light of recently published related work

  17. UNITED STATES DEPARTMENT OF TRANSPORTATION GLOBAL POSITIONING SYSTEM (GPS) ADJACENT BAND COMPATIBILITY ASSESSMENT

    Science.gov (United States)

    2018-04-01

    The goal of the U.S. Department of Transportation (DOT) Global Positioning System (GPS) Adjacent Band Compatibility Assessment is to evaluate the maximum transmitted power levels of adjacent band radiofrequency (RF) systems that can be tolerated by G...

  18. Report from the banding lab

    Science.gov (United States)

    Tautin, J.

    1995-01-01

    Mr. Tautin reported on the seemingly everchanging structure of biological science units within the Interior Department. Current Congressional proposals would either change the name of the Bird Banding Lab's parent agency or make it part of the Geological Survey. The current Congress has not looked favorably on science budgets within the Interior Department, and the Banding Lab's budget is being squeezed ever tighter.

  19. Temperature dependence of the fundamental band gap parameters ...

    Indian Academy of Sciences (India)

    the energy and broadening of the fundamental band gap have been evaluated using various models including the ... other crucial parameters including the operating temperatures of these devices. ... refrigeration system (Air Product Displex).

  20. Gravitational Analysis of the In-Band Wormhole Phenomenon

    National Research Council Canada - National Science Library

    Gopaul, Richard; Kruus, Peter; Sterne, Dan; Rivera, Brian

    2006-01-01

    ...], for evaluating the effects of in-band wormhole attacks on OLSR routing. The gravitational analysis technique examines individual network topologies and results in the creation of a gravitational chart for each topology...

  1. Dual-band infrared camera

    Science.gov (United States)

    Vogel, H.; Schlemmer, H.

    2005-10-01

    Every year, numerous accidents happen on European roads due to bad visibility (fog, night, heavy rain). Similarly, the dramatic aviation accidents of year 2001 in Milan and Zurich have reminded us that aviation safety is equally affected by reduced visibility. A dual-band thermal imager was developed in order to raise human situation awareness under conditions of reduced visibility especially in the automotive and aeronautical context but also for all transportation or surveillance tasks. The chosen wavelength bands are the Short Wave Infrared SWIR and the Long Wave Infrared LWIR band which are less obscured by reduced visibility conditions than the visible band. Furthermore, our field tests clearly show that the two different spectral bands very often contain complementary information. Pyramidal fusion is used to integrate complementary and redundant features of the multi-spectral images into a fused image which can be displayed on a monitor to provide more and better information for the driver or pilot.

  2. SINGLE-BAND, TRIPLE-BAND, OR MULTIPLE-BAND HUBBARD MODELS

    NARCIS (Netherlands)

    ESKES, H; SAWATZKY, GA

    1991-01-01

    The relevance of different models, such as the one-band t-J model and the three-band Emery model, as a realistic description of the electronic structure of high-T(c) materials is discussed. Starting from a multiband approach using cluster calculations and an impurity approach, the following

  3. Retrospective biodosimetry with small tooth enamel samples using K-Band and X-Band

    International Nuclear Information System (INIS)

    Gomez, Jorge A.; Kinoshita, Angela; Leonor, Sergio J.; Belmonte, Gustavo C.; Baffa, Oswaldo

    2011-01-01

    In an attempt to make the in vitro electron spin resonance (ESR) retrospective dosimetry of the tooth enamel a lesser invasive method, experiments using X-Band and K-Band were performed, aiming to determine conditions that could be used in cases of accidental exposures. First, a small prism from the enamel was removed and ground with an agate mortar and pestle until particles reach a diameter of approximately less than 0.5 mm. This enamel extraction process resulted in lower signal artifact compared with the direct enamel extraction performed with a diamond burr abrasion. The manual grinding of the enamel does not lead to any induced ESR signal artifact, whereas the use of a diamond burr at low speed produces a signal artifact equivalent to the dosimetric signal induced by a dose of 500 mGy of gamma irradiation. A mass of 25 mg of enamel was removed from a sound molar tooth previously irradiated in vitro with a dose of 100 mGy. This amount of enamel was enough to detect the dosimetric signal in a standard X-Band spectrometer. However using a K-Band spectrometer, samples mass between 5 and 10 mg were sufficient to obtain the same sensitivity. An overall evaluation of the uncertainties involved in the process in this and other dosimetric assessments performed at our laboratory indicates that it is possible at K-Band to estimate a 100 mGy dose with 25% accuracy. In addition, the use of K-Band also presented higher sensitivity and allowed the use of smaller sample mass in comparison with X-Band. Finally, the restoration process performed on a tooth after extraction of the 25 mg of enamel is described. This was conducted by dental treatment using photopolymerizable resin which enabled complete recovery of the tooth from the functional and aesthetic viewpoint showing that this procedure can be minimally invasive.

  4. Retrospective biodosimetry with small tooth enamel samples using K-Band and X-Band

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Jorge A. [Departamento de Fisica, FFCLRP, Universidade de Sao Paulo, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Kinoshita, Angela [Departamento de Fisica, FFCLRP, Universidade de Sao Paulo, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Universidade Sagrado Coracao - USC, 17011-160 Bauru, Sao Paulo (Brazil); Leonor, Sergio J. [Departamento de Fisica, FFCLRP, Universidade de Sao Paulo, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Belmonte, Gustavo C. [Universidade Sagrado Coracao - USC, 17011-160 Bauru, Sao Paulo (Brazil); Baffa, Oswaldo, E-mail: baffa@usp.br [Departamento de Fisica, FFCLRP, Universidade de Sao Paulo, 14040-901 Ribeirao Preto, Sao Paulo (Brazil)

    2011-09-15

    In an attempt to make the in vitro electron spin resonance (ESR) retrospective dosimetry of the tooth enamel a lesser invasive method, experiments using X-Band and K-Band were performed, aiming to determine conditions that could be used in cases of accidental exposures. First, a small prism from the enamel was removed and ground with an agate mortar and pestle until particles reach a diameter of approximately less than 0.5 mm. This enamel extraction process resulted in lower signal artifact compared with the direct enamel extraction performed with a diamond burr abrasion. The manual grinding of the enamel does not lead to any induced ESR signal artifact, whereas the use of a diamond burr at low speed produces a signal artifact equivalent to the dosimetric signal induced by a dose of 500 mGy of gamma irradiation. A mass of 25 mg of enamel was removed from a sound molar tooth previously irradiated in vitro with a dose of 100 mGy. This amount of enamel was enough to detect the dosimetric signal in a standard X-Band spectrometer. However using a K-Band spectrometer, samples mass between 5 and 10 mg were sufficient to obtain the same sensitivity. An overall evaluation of the uncertainties involved in the process in this and other dosimetric assessments performed at our laboratory indicates that it is possible at K-Band to estimate a 100 mGy dose with 25% accuracy. In addition, the use of K-Band also presented higher sensitivity and allowed the use of smaller sample mass in comparison with X-Band. Finally, the restoration process performed on a tooth after extraction of the 25 mg of enamel is described. This was conducted by dental treatment using photopolymerizable resin which enabled complete recovery of the tooth from the functional and aesthetic viewpoint showing that this procedure can be minimally invasive.

  5. Precipitation Estimation Using L-Band and C-Band Soil Moisture Retrievals

    Science.gov (United States)

    Koster, Randal D.; Brocca, Luca; Crow, Wade T.; Burgin, Mariko S.; De Lannoy, Gabrielle J. M.

    2016-01-01

    An established methodology for estimating precipitation amounts from satellite-based soil moisture retrievals is applied to L-band products from the Soil Moisture Active Passive (SMAP) and Soil Moisture and Ocean Salinity (SMOS) satellite missions and to a C-band product from the Advanced Scatterometer (ASCAT) mission. The precipitation estimates so obtained are evaluated against in situ (gauge-based) precipitation observations from across the globe. The precipitation estimation skill achieved using the L-band SMAP and SMOS data sets is higher than that obtained with the C-band product, as might be expected given that L-band is sensitive to a thicker layer of soil and thereby provides more information on the response of soil moisture to precipitation. The square of the correlation coefficient between the SMAP-based precipitation estimates and the observations (for aggregations to approximately100 km and 5 days) is on average about 0.6 in areas of high rain gauge density. Satellite missions specifically designed to monitor soil moisture thus do provide significant information on precipitation variability, information that could contribute to efforts in global precipitation estimation.

  6. The 3 micron ice band

    International Nuclear Information System (INIS)

    Greenberg, J.M.; Bult, C.E.P.M. van de

    1984-01-01

    Ever since it was proposed that H 2 O could be a dominant constituent of interstellar grains, its detection, or lack thereof, has played a large role in theories of grains and their evolution. It now appears possible to provide a basic theoretical structure for the evolution of grains in molecular clouds based on current observational evidence and laboratory experiments on the ice band. Both band strengths and shapes can be reasonably predicted by grain models. (U.K.)

  7. Superdeformed bands in 130Ce

    International Nuclear Information System (INIS)

    Paul, E.S.; Semple, A.T.; Boston, A.J.; Joss, D.T.; Nolan, P.J.; Shepherd, S.L.

    1997-01-01

    Four superdeformed bands have been assigned to 130 Ce following a high-statistics γ-ray study using the EUROGAM II spectrometer. The strongest band exhibits two distinct backbends which, in one scenario, may be interpreted as crossings between high-j N = 6 neutron orbitals (νi 13/2 ) and low-j N = 4 orbitals (νd 3/2 ) in an unpaired system. (author)

  8. Dipole Bands in 196Hg

    International Nuclear Information System (INIS)

    Lawrie, J. J.; Lawrie, E. A.; Newman, R. T.; Sharpey-Schafer, J. F.; Smit, F. D.; Msezane, B.; Benatar, M.; Mabala, G. K.; Mutshena, K. P.; Federke, M.; Mullins, S. M.; Ncapayi, N. J.; Vymers, P.

    2011-01-01

    High spin states in 196 Hg have been populated in the 198 Pt(α,6n) reaction at 65 MeV and the level scheme has been extended. A new dipole band has been observed and a previously observed dipole has been confirmed. Excitation energies, spins and parities of these bands were determined from DCO ratio and linear polarization measurements. Possible quasiparticle excitations responsible for these structures are discussed.

  9. Design of an Electronic Chest-Band

    Science.gov (United States)

    Atakan, R.; Acikgoz Tufan, H.; Baskan, H.; Eryuruk, S. H.; Akalin, N.; Kose, H.; Li, Y.; Kursun Bahadir, S.; Kalaoglu, F.

    2017-10-01

    In this study, an electronic chest strap prototype was designed for measuring fitness level, performance optimization, mobility and fall detection. Knitting technology is used for production by using highly elastic nylon yarn. In order to evaluate comfort performance of the garment, yarn strength and elongation, air permeability, moisture management and FAST tests (Fabric Assurance Fabric Testing) were carried out, respectively. After testing of textile part of the chest band, IMU sensors were integrated onto the garment by means of conductive yarns. Electrical conductivity of the circuit was also assessed at the end. Results indicated that the weight and the thickness of the product are relatively high for sports uses and it has a negative impact on comfort properties. However, it is highly stretchable and moisture management properties are still in acceptable values. From the perspective of possible application areas, developed smart chest band in this research could be used in sports facilities as well as health care applications for elderly and disabled people.

  10. Band-Structure of Thallium by the LMTO Method

    DEFF Research Database (Denmark)

    Holtham, P. M.; Jan, J. P.; Skriver, Hans Lomholt

    1977-01-01

    by an energy gap. The 6d and 7s bands were found to be far above the Fermi level and the 5d states were found to be far below it. Fermi surface properties and the electronic specific heat are computed and compared with experiment. The joint density of states has also been computed and is in reasonable...... and p bands for the HCP structure. Energy bands have been evaluated both with and without spin-orbit coupling which is particularly large in thallium. Energy bands close to the Fermi level were found to be mainly 6p like in character. The 6s states lay below the 6p bands and were separated from them......The relativistic band structure of thallium has been calculated using the linear muffin-tin orbital (LMTO) method. The positions and extents of the bands were found to follow the Wigner-Seitz rule approximately, and the origin of the dispersion of the bands was established from the canonical s...

  11. Single-Band and Dual-Band Infrared Detectors

    Science.gov (United States)

    Ting, David Z. (Inventor); Gunapala, Sarath D. (Inventor); Soibel, Alexander (Inventor); Nguyen, Jean (Inventor); Khoshakhlagh, Arezou (Inventor)

    2017-01-01

    Bias-switchable dual-band infrared detectors and methods of manufacturing such detectors are provided. The infrared detectors are based on a back-to-back heterojunction diode design, where the detector structure consists of, sequentially, a top contact layer, a unipolar hole barrier layer, an absorber layer, a unipolar electron barrier, a second absorber, a second unipolar hole barrier, and a bottom contact layer. In addition, by substantially reducing the width of one of the absorber layers, a single-band infrared detector can also be formed.

  12. Efficacy of pulmonary artery banding in patients with uneventricular defects

    Directory of Open Access Journals (Sweden)

    Ю. С. Синельников

    2015-10-01

    Full Text Available Long-term results where evaluated for different methods of pulmonary artery banding (PAB in 25 patients with univentricular congenital heart defects with used three methods. Hospital mortality was 8%. Second stage palliation was performed in 61% of patients. More tight PA banding in patients with univentriclar gave opportunity to perform 2nd stage of operation in 100% of patients, decrease complications and mortality rate, modify pulmonary circulation effectively.

  13. 47 CFR 90.531 - Band plan.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Band plan. 90.531 Section 90.531...-805 MHz Bands § 90.531 Band plan. This section sets forth the band plan for the 763-775 MHz and 793... and portables subject to Commission-approved regional planning committee regional plans. Transmitter...

  14. Metaphyseal bands in osteogenesis imperfecta

    Directory of Open Access Journals (Sweden)

    Suresh S

    2010-01-01

    Full Text Available An increasing number of patients with osteogenesis imperfecta are undergoing pamidronate therapy to prevent the incidence of fragility fractures. The authors herein report a child aged 3 years who received five cycles of pamidronate, resulting in metaphyseal bands, known as "zebra lines."

  15. Metaphyseal bands in osteogenesis imperfecta

    International Nuclear Information System (INIS)

    Suresh, SS; Thomas, John K

    2010-01-01

    An increasing number of patients with osteogenesis imperfecta are undergoing pamidronate therapy to prevent the incidence of fragility fractures. The authors herein report a child aged 3 years who received five cycles of pamidronate, resulting in metaphyseal bands, known as “zebra lines.”

  16. Identical high- K three-quasiparticle rotational bands

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Harjeet; Singh, Pardeep [Guru Nanak Dev University, Department of Physics, Amritsar (India)

    2016-12-15

    A comprehensive study of high-K three-quasiparticle rotational bands in odd-A nuclei indicates the similarity in γ-ray energies and dynamic moment of inertia I{sup (2)}. The extent of the identicality between the rotational bands is evaluated by using the energy factor method. For nuclei pairs exhibiting identical bands, the average relative change in the dynamic moment of inertia I{sup (2)} is also determined. The identical behaviour shown by these bands is attributed to the interplay of nuclear structure parameters: deformation and the pairing correlations. Also, experimental trend of the I(ℎ) vs. ℎω (MeV) plot for these nuclei pairs is shown to be in agreement with Tilted-Axis Cranking (TAC) model calculations. (orig.)

  17. Characterization of hydrometeors in Sahelian convective systems with an X-band radar and comparison with in situ measurements. Part I : Sensitivity of polarimetric radar particle identification retrieval and case study evaluation

    OpenAIRE

    Cazenave, Frédéric; Gosset, Marielle; Kacou, M.; Alcoba, M.; Fontaine, E.; Duroure, C.; Dolan, B.

    2016-01-01

    The particle identification scheme developed by Dolan and Rutledge for X-band polarimetric radar is tested for the first time in Africa and compared with in situ measurements. The data were acquired during the Megha-Tropiques mission algorithm-validation campaign that occurred in Niger in 2010. The radar classification is compared with the in situ observations gathered by an instrumented aircraft for the 13 August 2010 squall-line case. An original approach has been developed for the radar-in...

  18. Identical and shifted identical bands

    International Nuclear Information System (INIS)

    Dodder, R.S; Jones, E.F.; Hamilton, J.H.

    1997-01-01

    Spontaneous fission of 252 Cm was studied with 72 large Compton suppressed Ge detectors in Gamma sphere. New isotopes 160 Sm and 162 Gd were identified. Through X-ray-γ and γ-γ-γ) coincidence measurements, level energies were established to spins 14 + to 20 + in 152 , 154 156 60 Nd 92 94 96 , 156 , 158 , 160 62 Sm 94 , 96 , 98 , and 160 , 162 64 Gd 96 , 98 . These nuclei exhibit a remarkable variety of identical bands and bands where the energies and moments of inertia are shifted by the same constant amount for every spin state from 2 + to 12 + for various combinations of nuclei differing by 2n, 4n, 2p, 4p, and α

  19. NCenter wide band neutrino beam

    International Nuclear Information System (INIS)

    Stutte, L.G.

    1985-01-01

    This memo describes the physical properties of the currently operating N-Center wide band neutrino beam---commonly called the triplet train, following a past tradition of a triplet lens configuration. In reality, in order to gain a larger momentum acceptance and to minimize the angular divergence of the beam, a quadruplet beam (4 lenses) employing point-to-parallel optics at a central momentum of 300 GeV was built. 6 refs., 13 figs., 1 tab

  20. [Gastric band erosion: Alternative management].

    Science.gov (United States)

    Echaverry-Navarrete, Denis José; Maldonado-Vázquez, Angélica; Cortes-Romano, Pablo; Cabrera-Jardines, Ricardo; Mondragón-Pinzón, Erwin Eduardo; Castillo-González, Federico Armando

    2015-01-01

    Obesity is a public health problem, for which the prevalence has increased worldwide at an alarming rate, affecting 1.7 billion people in the world. To describe the technique employed in incomplete penetration of gastric band where endoscopic management and/or primary closure is not feasible. Laparoscopic removal of gastric band was performed in five patients with incomplete penetrance using Foley catheterization in the perforation site that could lead to the development of a gastro-cutaneous fistula. The cases presented include a leak that required surgical lavage with satisfactory outcome, and one patient developed stenosis 3 years after surgical management, which was resolved endoscopically. In all cases, the penetration site closed spontaneously. Gastric band erosion has been reported in 3.4% of cases. The reason for inserting a catheter is to create a controlled gastro-cutaneous fistula, allowing spontaneous closure. Various techniques have been described: the totally endoscopic, hybrid techniques (endoscopic/laparoscopic) and completely laparoscopic. A technique is described here that is useful and successful in cases where the above-described treatments are not viable. Copyright © 2015. Published by Masson Doyma México S.A.

  1. More on Estimation of Banded and Banded Toeplitz Covariance Matrices

    OpenAIRE

    Berntsson, Fredrik; Ohlson, Martin

    2017-01-01

    In this paper we consider two different linear covariance structures, e.g., banded and bended Toeplitz, and how to estimate them using different methods, e.g., by minimizing different norms. One way to estimate the parameters in a linear covariance structure is to use tapering, which has been shown to be the solution to a universal least squares problem. We know that tapering not always guarantee the positive definite constraints on the estimated covariance matrix and may not be a suitable me...

  2. Glucose Absorption by the Bacillary Band of Trichuris muris.

    Directory of Open Access Journals (Sweden)

    Tina V A Hansen

    2016-09-01

    Full Text Available A common characteristic of Trichuris spp. infections in humans and animals is the variable but low efficacy of single-dose benzimidazoles currently used in mass drug administration programmes against human trichuriasis. The bacillary band, a specialised morphological structure of Trichuris spp., as well as the unique partly intracellular habitat of adult Trichuris spp. may affect drug absorption and perhaps contribute to the low drug accumulation in the worm. However, the exact function of the bacillary band is still unknown.We studied the dependency of adult Trichuris muris on glucose and/or amino acids for survival in vitro and the absorptive function of the bacillary band. The viability of the worms was evaluated using a motility scale from 0 to 3, and the colorimetric assay Alamar Blue was utilised to measure the metabolic activity. The absorptive function of the bacillary band in living worms was explored using a fluorescent glucose analogue (6-NBDG and confocal microscopy. To study the absorptive function of the bacillary band in relation to 6-NBDG, the oral uptake was minimised or excluded by sealing the oral cavity with glue and agarose.Glucose had a positive effect on both the motility (p < 0.001 and metabolic activity (p < 0.001 of T. muris in vitro, whereas this was not the case for amino acids. The 6-NBDG was observed in the pores of the bacillary band and within the stichocytes of the living worms, independent of oral sealing.Trichuris muris is dependent on glucose for viability in vitro, and the bacillary band has an absorptive function in relation to 6-NBDG, which accumulates within the stichocytes. The absorptive function of the bacillary band calls for an exploration of its possible role in the uptake of anthelmintics, and as a potential anthelmintic target relevant for future drug development.

  3. Optical band gaps of organic semiconductor materials

    Science.gov (United States)

    Costa, José C. S.; Taveira, Ricardo J. S.; Lima, Carlos F. R. A. C.; Mendes, Adélio; Santos, Luís M. N. B. F.

    2016-08-01

    UV-Vis can be used as an easy and forthright technique to accurately estimate the band gap energy of organic π-conjugated materials, widely used as thin films/composites in organic and hybrid electronic devices such as OLEDs, OPVs and OFETs. The electronic and optical properties, including HOMO-LUMO energy gaps of π-conjugated systems were evaluated by UV-Vis spectroscopy in CHCl3 solution for a large number of relevant π-conjugated systems: tris-8-hydroxyquinolinatos (Alq3, Gaq3, Inq3, Al(qNO2)3, Al(qCl)3, Al(qBr)3, In(qNO2)3, In(qCl)3 and In(qBr)3); triphenylamine derivatives (DDP, p-TTP, TPB, TPD, TDAB, m-MTDAB, NPB, α-NPD); oligoacenes (naphthalene, anthracene, tetracene and rubrene); oligothiophenes (α-2T, β-2T, α-3T, β-3T, α-4T and α-5T). Additionally, some electronic properties were also explored by quantum chemical calculations. The experimental UV-Vis data are in accordance with the DFT predictions and indicate that the band gap energies of the OSCs dissolved in CHCl3 solution are consistent with the values presented for thin films.

  4. Band Subset Selection for Hyperspectral Image Classification

    Directory of Open Access Journals (Sweden)

    Chunyan Yu

    2018-01-01

    Full Text Available This paper develops a new approach to band subset selection (BSS for hyperspectral image classification (HSIC which selects multiple bands simultaneously as a band subset, referred to as simultaneous multiple band selection (SMMBS, rather than one band at a time sequentially, referred to as sequential multiple band selection (SQMBS, as most traditional band selection methods do. In doing so, a criterion is particularly developed for BSS that can be used for HSIC. It is a linearly constrained minimum variance (LCMV derived from adaptive beamforming in array signal processing which can be used to model misclassification errors as the minimum variance. To avoid an exhaustive search for all possible band subsets, two numerical algorithms, referred to as sequential (SQ and successive (SC algorithms are also developed for LCMV-based SMMBS, called SQ LCMV-BSS and SC LCMV-BSS. Experimental results demonstrate that LCMV-based BSS has advantages over SQMBS.

  5. The DSS-14 C-band exciter

    Science.gov (United States)

    Rowan, D. R.

    1989-01-01

    The development and implementation of a C-band exciter for use with the Block IV Receiver-Exciter Subsystem at Deep Space Station 14 (DSS-14) has been completed. The exciter supplements the standard capabilities of the Block IV system by providing a drive signal for the C-band transmitter while generating coherent translation frequencies for C-band (5-GHz) to S-band (2.2- to 2.3-GHz) Doppler extraction, C-band to L-band (1.6-GHz) zero delay measurements, and a level calibrated L-band test signal. Exciter functions are described, and a general explanation and description of the C-band uplink controller is presented.

  6. Robust and adaptive band-to-band image transform of UAS miniature multi-lens multispectral camera

    Science.gov (United States)

    Jhan, Jyun-Ping; Rau, Jiann-Yeou; Haala, Norbert

    2018-03-01

    Utilizing miniature multispectral (MS) or hyperspectral (HS) cameras by mounting them on an Unmanned Aerial System (UAS) has the benefits of convenience and flexibility to collect remote sensing imagery for precision agriculture, vegetation monitoring, and environment investigation applications. Most miniature MS cameras adopt a multi-lens structure to record discrete MS bands of visible and invisible information. The differences in lens distortion, mounting positions, and viewing angles among lenses mean that the acquired original MS images have significant band misregistration errors. We have developed a Robust and Adaptive Band-to-Band Image Transform (RABBIT) method for dealing with the band co-registration of various types of miniature multi-lens multispectral cameras (Mini-MSCs) to obtain band co-registered MS imagery for remote sensing applications. The RABBIT utilizes modified projective transformation (MPT) to transfer the multiple image geometry of a multi-lens imaging system to one sensor geometry, and combines this with a robust and adaptive correction (RAC) procedure to correct several systematic errors and to obtain sub-pixel accuracy. This study applies three state-of-the-art Mini-MSCs to evaluate the RABBIT method's performance, specifically the Tetracam Miniature Multiple Camera Array (MiniMCA), Micasense RedEdge, and Parrot Sequoia. Six MS datasets acquired at different target distances and dates, and locations are also applied to prove its reliability and applicability. Results prove that RABBIT is feasible for different types of Mini-MSCs with accurate, robust, and rapid image processing efficiency.

  7. Table of superdeformed nuclear bands and fission isomers

    International Nuclear Information System (INIS)

    Firestone, R.B.; Singh, B.

    1994-06-01

    A minimum in the second potential well of deformed nuclei was predicted and the associated shell gaps are illustrated in the harmonic oscillator potential shell energy surface calculations shown in this report. A strong superdeformed minimum in 152 Dy was predicted for β 2 -0.65. Subsequently, a discrete set of γ-ray transitions in 152 DY was observed and, assigned to the predicted superdeformed band. Extensive research at several laboratories has since focused on searching for other mass regions of large deformation. A new generation of γ-ray detector arrays is already producing a wealth of information about the mechanisms for feeding and deexciting superdeformed bands. These bands have been found in three distinct regions near A=l30, 150, and 190. This research extends upon previous work in the actinide region near A=240 where fission isomers were identified and also associated with the second potential well. Quadrupole moment measurements for selected cases in each mass region are consistent with assigning the bands to excitations in the second local minimum. As part of our committment to maintain nuclear structure data as current as possible in the Evaluated Nuclear Structure Reference File (ENSDF) and the Table of Isotopes, we have updated the information on superdeformed nuclear bands. As of April 1994, we have complied data from 86 superdeformed bands and 46 fission isomers identified in 73 nuclides for this report. For each nuclide there is a complete level table listing both normal and superdeformed band assignments; level energy, spin, parity, half-life, magneto moments, decay branchings; and the energies, final levels, relative intensities, multipolarities, and mixing ratios for transitions deexciting each level. Mass excess, decay energies, and proton and neutron separation energies are also provided from the evaluation of Audi and Wapstra

  8. Table of superdeformed nuclear bands and fission isomers

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, R.B. [Lawrence Berkeley Lab., CA (United States); Singh, B. [McMaster Univ., Hamilton, ON (Canada)

    1994-06-01

    A minimum in the second potential well of deformed nuclei was predicted and the associated shell gaps are illustrated in the harmonic oscillator potential shell energy surface calculations shown in this report. A strong superdeformed minimum in {sup 152}Dy was predicted for {beta}{sub 2}-0.65. Subsequently, a discrete set of {gamma}-ray transitions in {sup 152}DY was observed and, assigned to the predicted superdeformed band. Extensive research at several laboratories has since focused on searching for other mass regions of large deformation. A new generation of {gamma}-ray detector arrays is already producing a wealth of information about the mechanisms for feeding and deexciting superdeformed bands. These bands have been found in three distinct regions near A=l30, 150, and 190. This research extends upon previous work in the actinide region near A=240 where fission isomers were identified and also associated with the second potential well. Quadrupole moment measurements for selected cases in each mass region are consistent with assigning the bands to excitations in the second local minimum. As part of our committment to maintain nuclear structure data as current as possible in the Evaluated Nuclear Structure Reference File (ENSDF) and the Table of Isotopes, we have updated the information on superdeformed nuclear bands. As of April 1994, we have complied data from 86 superdeformed bands and 46 fission isomers identified in 73 nuclides for this report. For each nuclide there is a complete level table listing both normal and superdeformed band assignments; level energy, spin, parity, half-life, magneto moments, decay branchings; and the energies, final levels, relative intensities, multipolarities, and mixing ratios for transitions deexciting each level. Mass excess, decay energies, and proton and neutron separation energies are also provided from the evaluation of Audi and Wapstra.

  9. Study of rotational band in 111Sn

    International Nuclear Information System (INIS)

    Ganguly, S.; Banerjee, P.; Ray, I.; Kshetri, R.; Raut, R.; Goswami, A.; Saha Sarkar, M.; Bhattacharya, S.; Mukherjee, A.; Mukherjee, G.; Basu, S.K.; Mukhopadhyay, S.

    2006-01-01

    The motivation of the present work is to study the negative-parity rotational band in 111 Sn. Study of the lifetimes of the states of the rotational band is expected to provide information on their structures as well as the band termination phenomenon

  10. Prenatal diagnosis of amniotic band syndrome

    Directory of Open Access Journals (Sweden)

    Laxmi Devi Padmanabhan

    2016-01-01

    Full Text Available Amniotic band can cause a broad spectrum of anomalies ranging from simple band constrictions to major craniofacial and visceral defects. It can cause significant neonatal morbidity. Accurate diagnosis will help in the management of the present pregnancy and in counseling with regard to future pregnancies. Here we report three cases of amniotic band syndrome detected in the prenatal period.

  11. Complex band structure and electronic transmission eigenchannels

    DEFF Research Database (Denmark)

    Jensen, Anders; Strange, Mikkel; Smidstrup, Soren

    2017-01-01

    and complex band structure, in this case individual eigenchannel transmissions and different complex bands. We present calculations of decay constants for the two most conductive states as determined by complex band structure and standard DFT Landauer transport calculations for one semi-conductor and two...

  12. High-energy band structure of gold

    DEFF Research Database (Denmark)

    Christensen, N. Egede

    1976-01-01

    The band structure of gold for energies far above the Fermi level has been calculated using the relativistic augmented-plane-wave method. The calculated f-band edge (Γ6-) lies 15.6 eV above the Fermi level is agreement with recent photoemission work. The band model is applied to interpret...

  13. Multi-band Modelling of Appearance

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Larsen, Rasmus

    2003-01-01

    the appearance of both derived feature bands and an intensity band. As a special case of feature-band augmented appearance modelling we propose a dedicated representation with applications to face segmentation. The representation addresses a major problem within face recognition by lowering the sensitivity...

  14. Multi-band Modelling of Appearance

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Larsen, Rasmus

    2002-01-01

    the appearance of both derived feature bands and an intensity band. As a special case of feature-band augmented appearance modelling we propose a dedicated representation with applications to face segmentation. The representation addresses a major problem within face recognition by lowering the sensitivity...

  15. Endoscopic variceal band ligation: a local experience | Jani | East ...

    African Journals Online (AJOL)

    Objective: To evaluate the results of endoscopic variceal band ligation (EVBL) in the local set-up. Design: Retrospective analysis of data of all patients who had EVBL. Setting: Patients having EVBL at the office endoscopy suite. The Nairobi Hospital, the Aga Khan Hospital and M.P Shah Hospital. Methods: The varices were ...

  16. Thematic mapper studies band correlation analysis

    Science.gov (United States)

    Ungar, S. G.; Kiang, R.

    1976-01-01

    Spectral data representative of thematic mapper candidate bands 1 and 3 to 7 were obtained by selecting appropriate combinations of bands from the JSC 24 channel multispectral scanner. Of all the bands assigned, only candidate bands 4 (.74 mu to .80 mu) and 5 (.80 mu to .91 mu) showed consistently high intercorrelation from region to region and time to time. This extremely high correlation persisted when looking at the composite data set in a multitemporal, multilocation domain. The GISS investigations lend positive confirmation to the hypothesis, that TM bands 4 and 5 are redundant.

  17. Dust bands in the asteroid belt

    International Nuclear Information System (INIS)

    Sykes, M.V.; Greenberg, R.; Dermott, S.F.; Nicholson, P.D.; Burns, J.A.

    1989-01-01

    This paper describes the original IRAS observations leading to the discovery of the three dust bands in the asteroid belt and the analysis of data. Special attention is given to an analytical model of the dust band torus and to theories concerning the origin of the dust bands, with special attention given to the collisional equilibrium (asteroid family), the nonequilibrium (random collision), and the comet hypotheses of dust-band origin. It is noted that neither the equilibrium nor nonequilibrium models, as currently formulated, present a complete picture of the IRAS dust-band observations. 32 refs

  18. Bunch monitor for an S-band electron linear accelerator

    International Nuclear Information System (INIS)

    Otake, Yuji; Nakahara, Kazuo

    1991-01-01

    The measurement of bunch characteristics in an S-band electron linear accelerator is required in order to evaluate the quality of accelerated electron beams. A new-type bunch monitor has been developed which combines micro-stripline technology with an air insulator and wall-current monitoring technology. The obtained time resolution of the monitor was more than 150 ps. This result shows that the monitor can handle the bunch number of an S-band linac. The structure of the monitor is suitable for being installed in the vacuum area, since it is constructed of only metal and ceramic parts. It can therefore easily be employed in an actual machine

  19. Table of members of quasi-bands

    International Nuclear Information System (INIS)

    Sakai, Mitsuo.

    1984-04-01

    The probable members of the quasi-bands in even-even nuclei for Z between 6 and 100 are listed in this table. The terms quasi-bands have been introduced in the so-called spherical regions as the counter parts of the collective bands in the deformed regions. In the present compilation, the data for deformed nuclei are classified for convenience under the same titles, Quasi-Ground Band, Quasi-Beta Band and Quasi-Gamma Band, as are used for other nuclear regions. The present edition covers the literature through September, 1983. Fifteen newly discovered nuclides are included. The classification of energy level into quasi-bands is made on the basis of the systematic trend in the data over large groups of nuclei. (Kato, T.)

  20. A Novel Ku-Band/Ka-Band and Ka-Band/E-Band Multimode Waveguide Couplers for Power Measurement of Traveling-Wave Tube Amplifier Harmonic Frequencies

    Science.gov (United States)

    Wintucky, Edwin G.; Simons, Rainee N.

    2015-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler, fabricated from two dissimilar frequency band waveguides, is capable of isolating power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT) amplifier. Test results from proof-of-concept demonstrations are presented for a Ku-band/Ka-band MDC and a Ka-band/E-band MDC. In addition to power measurements at harmonic frequencies, a potential application of the MDC is in the design of a satellite borne beacon source for atmospheric propagation studies at millimeter-wave (mm-wave) frequencies (Ka-band and E-band).

  1. Liquor oligoclonal bands assay: interpretation, correlation with other laboratory assays and importance for diagnostics of neurological disorders

    OpenAIRE

    Bagdonas, Dovydas

    2017-01-01

    Aim: to analyse the possible relationship between liquor IgG oligoclonal bands assay and other laboratory assays in neurological patients. Objectives: to determine the frequency of oligoclonal bands in neurological patients; to compare the results between serum and liquor laboratory assays in dependence of oligoclonal bands assay results; to evaluate the relationships between oligoclonal bands assay and serological-immunological assays for infectious diseases, gender, age and neurological ...

  2. Dual-band frequency selective surface with large band separation and stable performance

    Science.gov (United States)

    Zhou, Hang; Qu, Shao-Bo; Peng, Wei-Dong; Lin, Bao-Qin; Wang, Jia-Fu; Ma, Hua; Zhang, Jie-Qiu; Bai, Peng; Wang, Xu-Hua; Xu, Zhuo

    2012-05-01

    A new technique of designing a dual-band frequency selective surface with large band separation is presented. This technique is based on a delicately designed topology of L- and Ku-band microwave filters. The two band-pass responses are generated by a capacitively-loaded square-loop frequency selective surface and an aperture-coupled frequency selective surface, respectively. A Faraday cage is located between the two frequency selective surface structures to eliminate undesired couplings. Based on this technique, a dual-band frequency selective surface with large band separation is designed, which possesses large band separation, high selectivity, and stable performance under various incident angles and different polarizations.

  3. [Rubber band ligation in treatment of hemorrhoids: our experience].

    Science.gov (United States)

    Gaj, F; Biviano, I; Sportelli, G; Candeloro, L

    2015-01-01

    Hemorrhoids are a very common condition. The treatment depends upon persistence and severity of symptoms. For hemorrhoids of II and III grade the rubber band ligation may be therapeutic. Our aim is to report the outcomes of rubber band ligation of hemorrhoids, with a follow up of 6 months. A total of 50 patients underwent rubber band ligation for symptomatic hemorrhoids (grade II and III) without prolapse, between June 2012 and June 2014. All patients underwent plug test to rule out presence of rectal mucosal prolapse and were classified according to PATE classification (1). Each hemorrhoid was ligated with one rubber band through a ligator. All patients were evaluated immediately at the end of the procedure, after ten days and six months after the treatment. Patient's demographic and operative data were collected and analyzed. The mean patients age was 47.6±12.3 years (range 24-72). All procedures were performed without complications. Before rubber band ligation, 42 patients had rectal bleeding, 38 had perineal discomfort and 27 had itching. Ten days after the treatment, 12 patients presented self-limited rectal bleeding, but 10 of these had more hemorrhoids and underwent a second rubber band ligation. No patients complained perineal discomfort, and 8 patients had itching; 78% and 16% of patients respectively, experienced feeling of a foreign body inside the canal anal and anal pain. After 6 months, only 13 patients were occasionally symptomatic: 4 patients had rectal bleeding, 2 had perineal discomfort and 4 had itching. Three more patients presented both perineal discomfort and hitching. None had the feeling of a foreign body in anal canal or anal pain. Rubber band ligation is an efficacious, cost-effective and simple treatment for the second and third degree hemorrhoids without rectal mucosal prolapsed. In our hands, no severe complications developed and minor complications could be handled with ease.

  4. Evaluation de l'impact des cours d'eau sur l'eutrophisation dans la bande côtière : nécessité de raisonner sur les concentrations et sur les flux

    Directory of Open Access Journals (Sweden)

    Aurousseau, P.

    2013-01-01

    Full Text Available Assessing the impact of streams on eutrophication in the coastal strip: the need to consider concentrations and loads. The approach of using measurements of water quality concentrations has been favored to date because of the current standards for drinking water, which are defined in terms of concentration. For example, the standard for the concentration of nitrate is 50 mg·l-1, although this standard, in fact, derives from a limited quantity of nitrate absorbed by drinking water with a concentration of 20 mg nitrogen per day. The dual assessment of flow and concentration is essential when studying environmental impacts because the intensity of these impacts is mainly linked to the quantity of nutrients reaching a compartment of the environment. This link between nutrient load and environmental impact is particularly established in coastal marine environments exposed to the phenomena of green tides, diatoms or Phaeocystis blooms. At the watershed scale, flow control presents some metrological problems but assessment based on flow has the advantage of providing a better comparison of the overall impact (at the coastal band scale of several watersheds. At the catchment scale, in order to reduce the outflow, it is important to intervene at the level of the inflow by reducing any excesses in the N and P balance. This approach is illustrated by the example of the eutrophication of coastal marine water in the Eastern English Channel and at the mouth of the North Sea.

  5. Photonic band gap structure simulator

    Science.gov (United States)

    Chen, Chiping; Shapiro, Michael A.; Smirnova, Evgenya I.; Temkin, Richard J.; Sirigiri, Jagadishwar R.

    2006-10-03

    A system and method for designing photonic band gap structures. The system and method provide a user with the capability to produce a model of a two-dimensional array of conductors corresponding to a unit cell. The model involves a linear equation. Boundary conditions representative of conditions at the boundary of the unit cell are applied to a solution of the Helmholtz equation defined for the unit cell. The linear equation can be approximated by a Hermitian matrix. An eigenvalue of the Helmholtz equation is calculated. One computation approach involves calculating finite differences. The model can include a symmetry element, such as a center of inversion, a rotation axis, and a mirror plane. A graphical user interface is provided for the user's convenience. A display is provided to display to a user the calculated eigenvalue, corresponding to a photonic energy level in the Brilloin zone of the unit cell.

  6. Reliability of flipper-banded penguins as indicators of climate change.

    Science.gov (United States)

    Saraux, Claire; Le Bohec, Céline; Durant, Joël M; Viblanc, Vincent A; Gauthier-Clerc, Michel; Beaune, David; Park, Young-Hyang; Yoccoz, Nigel G; Stenseth, Nils C; Le Maho, Yvon

    2011-01-13

    In 2007, the Intergovernmental Panel on Climate Change highlighted an urgent need to assess the responses of marine ecosystems to climate change. Because they lie in a high-latitude region, the Southern Ocean ecosystems are expected to be strongly affected by global warming. Using top predators of this highly productive ocean (such as penguins) as integrative indicators may help us assess the impacts of climate change on marine ecosystems. Yet most available information on penguin population dynamics is based on the controversial use of flipper banding. Although some reports have found the effects of flipper bands to be deleterious, some short-term (one-year) studies have concluded otherwise, resulting in the continuation of extensive banding schemes and the use of data sets thus collected to predict climate impact on natural populations. Here we show that banding of free-ranging king penguins (Aptenodytes patagonicus) impairs both survival and reproduction, ultimately affecting population growth rate. Over the course of a 10-year longitudinal study, banded birds produced 41% [corrected] fewer chicks and had a survival rate 16 percentage points [corrected] lower than non-banded birds, demonstrating a massive long-term impact of banding and thus refuting the assumption that birds will ultimately adapt to being banded. Indeed, banded birds still arrived later for breeding at the study site and had longer foraging trips even after 10 years. One of our major findings is that responses of flipper-banded penguins to climate variability (that is, changes in sea surface temperature and in the Southern Oscillation index) differ from those of non-banded birds. We show that only long-term investigations may allow an evaluation of the impact of flipper bands and that every major life-history trait can be affected, calling into question the banding schemes still going on. In addition, our understanding of the effects of climate change on marine ecosystems based on flipper-band

  7. Broad-band beam buncher

    International Nuclear Information System (INIS)

    Goldberg, D.A.; Flood, W.S.; Arthur, A.A.; Voelker, F.

    1986-01-01

    This patent describes a broad-band beam buncher. This beam buncher consists of: a housing adapted to be eacuated, an electron gun in the housing for producing a beam of electrons, buncher means in the housing forming a buncher cavity which has an entrance opening for receiving the electron beam and an exit opening through which the electron beam passes out of the buncher cavity, a drift tube electrode in the buncher cavity and disposed between the entrance opening and the exit opening with first and second gaps between the drift tube electrode and the entrance and exit openings, the drift tube electrode which has a first drift space through which the electron beam passes in traveling between the entrance and exit openings, modulating means for supplying an ultrahigh frequeny modulating signal to the drift tube electrode for producing velocity modulation of the electrons in the electron beam as the electrons pass through the buncher cavity and the drift tube electrode between the entrance opening and the exit opening, drift space means in the housing forming a second drift space for receiving the velocity modulated electron beam from the exit opening, the velocity modulated electron beam being bunched as it passes along the second drift space, the drift space means has a discharge opening through which the electron beam is discharged from the second drift space after being bunched therein, the modulating means containing a signal source for producing an ultrahigh frequency signal, a transmission line connected between the signal source and the drift tube electrode, and terminating means connected to the drift tube electrode for terminating the transmission line in approximately its characteristic impedance to afford a broad response band with minimum 6 variations therein

  8. Small Bowel Obstruction due to Anomalous Congenital Bands in Children

    Directory of Open Access Journals (Sweden)

    Basak Erginel

    2016-01-01

    Full Text Available Introduction. The aim of the study was to evaluate our children who are operated on for anomalous congenital band while increasing the awareness of this rare reason of intestinal obstruction in children which causes a diagnostic challenge. Patients and Methods. We retrospectively reviewed the records of fourteen children treated surgically for intestinal obstructions caused by anomalous congenital bands. Results. The bands were located between the following regions: the ascending colon and the mesentery of the terminal ileum in 4 patients, the jejunum and mesentery of the terminal ileum in 3 patients, the ileum and mesentery of the terminal ileum in 2 patients, the ligament of Treitz and mesentery of the jejunum in one patient, the ligament of Treitz and mesentery of the terminal ileum in one patient, duodenum and duodenum in one patient, the ileum and mesentery of the ileum in one patient, the jejunum and mesentery of the jejunum in one patient, and Meckel’s diverticulum and its ileal mesentery in one patient. Band excision was adequate in all of the patients except the two who received resection anastomosis for intestinal necrosis. Conclusion. Although congenital anomalous bands are rare, they should be considered in the differential diagnosis of patients with an intestinal obstruction.

  9. Banded vs Bonded Space Maintainers: Finding Better Way Out.

    Science.gov (United States)

    Setia, Vikas; Kumar Pandit, Inder; Srivastava, Nikhil; Gugnani, Neeraj; Gupta, Monika

    2014-05-01

    Of this in vivo study was to evaluate various space maintainers in terms of survival rate, gingival health and presence of caries. A total of 60 extraction sites in the age group of 4 to 9 years were divided into four groups and different space maintainers were placed in them viz (conventional band and loop, prefabricated band with custom made loop, Ribbond, Super splint). Prefabricated bands with custom made loop showed maximum success rates (84.6%), while super splint (33.33%) was found to be least successful. In terms of gingival health, prefabricated band with custom made loop reported minimum cases with poor gingival health (27.2%), while maximum cases with poor gingival health (50%) were reported with Super splint. None of the space maintainers developed caries at the end of 9 months. How to cite this article: Setia v, Pandit IK, Srivastava N, Gugnani N, Gupta M. Banded vs Bonded Space Maintainers: Finding Better Way Out. Int J Clin Pediatr Dent 2014;7(2):97-104.

  10. Band 3 in aging and neurological disease.

    Science.gov (United States)

    Kay, M M

    1991-01-01

    Senescent cell antigen appears on old cells and marks them for death by initiating the binding of IgG autoantibody and subsequent removal by phagocytes in mammals and other vertebrates. We have created a synthetic aging antigen that blocks binding of IgG to senescent cells in vitro. Synthetic senescent cell antigen might be effective in preventing cellular destruction in vivo in certain diseases, and can be used to manipulate cellular life span in situ. Senescent cell antigen is generated by the modification of an important structural and transport membrane molecule, protein band 3. Band 3 is present in cellular, nuclear, Golgi, and mitochondrial membranes as well as in cell membranes. Band 3 proteins in nucleated cells participate in cell surface patching and capping. Band 3 maintains acid-base balance by mediating the exchange of anions (e.g., chloride, bicarbonate), and is the binding site for glycolytic enzymes. It is responsible for CO2 exchange in all tissues and organs. Thus, it is the most heavily used anion transport system in the body. Band 3 is a major transmembrane structural protein which attaches the plasma membrane to the internal cell cytoskeleton by binding to band 2.1 (ankyrin). Oxidation generates senescent cell antigen in situ. Band 3 is present in the central nervous system, and differences have been described in band 3 between young and aging brain tissue. One autosomal recessive neurological disease, choreoacanthocytosis, is associated with band 3 abnormalities. The 150 residues of the carboxyl terminus segment of band 3 appear to be altered. In brains from Alzheimer's disease patients, antibodies to aged band 3 label the amyloid core of classical plaques and the microglial cells located in the middle of the plaque in tissue sections, and an abnormal band 3 in immunoblots. Band 3 protein(s) in mammalian brain performs the same functions as that of erythroid band 3. These functions is anion transport, ankyrin binding, and generation of

  11. The dynamics of a shear band

    Science.gov (United States)

    Giarola, Diana; Capuani, Domenico; Bigoni, Davide

    2018-03-01

    A shear band of finite length, formed inside a ductile material at a certain stage of a continued homogeneous strain, provides a dynamic perturbation to an incident wave field, which strongly influences the dynamics of the material and affects its path to failure. The investigation of this perturbation is presented for a ductile metal, with reference to the incremental mechanics of a material obeying the J2-deformation theory of plasticity (a special form of prestressed, elastic, anisotropic, and incompressible solid). The treatment originates from the derivation of integral representations relating the incremental mechanical fields at every point of the medium to the incremental displacement jump across the shear band faces, generated by an impinging wave. The boundary integral equations (under the plane strain assumption) are numerically approached through a collocation technique, which keeps into account the singularity at the shear band tips and permits the analysis of an incident wave impinging a shear band. It is shown that the presence of the shear band induces a resonance, visible in the incremental displacement field and in the stress intensity factor at the shear band tips, which promotes shear band growth. Moreover, the waves scattered by the shear band are shown to generate a fine texture of vibrations, parallel to the shear band line and propagating at a long distance from it, but leaving a sort of conical shadow zone, which emanates from the tips of the shear band.

  12. Quadrupole collective correlations and termination of the superdeformed bands in mercury

    International Nuclear Information System (INIS)

    Bonche, P.; Heenen, P.H.; Krieger, S.J.; Weiss, M.S.; Meyer, J.

    1990-03-01

    Fully self-consistent Generator Coordinate Method calculations have been performed on a basis of quadrupole constrained Hartree-Fock plus BCS wave functions for the five even mercury isotopes 190-198 Hg. The GCM results support conclusions drawn from previous HF+BCS calculations. The predicted evolution of superdeformed band head (shape isomer) properties as a function of the neutron number is consistent with the data. Using calculated transition matrix elements, we evaluate in-band versus out-of-band quadrupole decay and explain the sudden termination of the superdeformed band

  13. Intruder bands in Z = 51 nuclei

    International Nuclear Information System (INIS)

    LaFosse, D.R.

    1993-01-01

    Recent investigations of h 11/2 proton intruder bands in odd 51 Sb nuclei are reported. In addition to experiments performed at SUNY Stony Brook and Chalk River, data from Early Implementation of GAMMASPHERE (analysis in progress) are presented. In particular, the nuclei 109 Sb and 111 Sb are discussed. Rotational bands based on the πh 11/2 orbital coupled to a 2p2h deformed state of the 50 Sn core have been observed. These bands have been observed to high spin, and in the case of 109 Sb to a rotational frequency of 1.4 MeV, the highest frequency observed in a heavy nucleus. The dynamic moments of inertia in these bands decrease slowly with frequency, suggesting a gradual band termination. The systematics of such bands in 109-119 Sb will be discussed

  14. Adiabatic pressure dependence of the 2.7 and 1.9 micron water vapor bands

    Science.gov (United States)

    Mathai, C. V.; Walls, W. L.; Broersma, S.

    1977-01-01

    An acoustic excitation technique is used to determine the adiabatic pressure derivative of the spectral absorptance of the 2.7 and 1.9 micron water vapor bands, and the 3.5 micron HCl band. The dependence of this derivative on thermodynamic parameters such as temperature, concentration, and pressure is evaluated. A cross-flow water vapor system is used to measure spectral absorptance. Taking F as the ratio of nonrigid to rotor line strengths, it is found that an F factor correction is needed for the 2.7 micron band. The F factor for the 1.9 micron band is also determined. In the wings of each band a wavelength can be found where the concentration dependence is predominant. Farther out in the wings a local maximum occurs for the temperature derivative. It is suggested that the pressure derivative is significant in the core of the band.

  15. Amniotic band syndrome: A clinical brief

    Directory of Open Access Journals (Sweden)

    Dasaradha Ramireddy Malireddy

    2017-01-01

    Full Text Available Amniotic band syndrome (ABS results from bands of amnion entangling fetal parts. They may manifest as constriction rings or complex congenital anomalies resulting in stillbirth. Karyotyping is important for exclusion of inherited disorders and proper counseling. Two case reports one stillbirth and the other with constriction ring of fingers and mild hydronephrosis are presented. The aim of this paper is to make awareness and stress the need for doing thorough work-up in all cases of constriction bands.

  16. Fade Mitigation Techniques at Ka-Band

    Science.gov (United States)

    Dissanayake, Asoka (Editor)

    1996-01-01

    Rain fading is the dominant propagation impairment affecting Ka-band satellite links and rain fade mitigation is a key element in the design of Ka-band satellite networks. Some of the common fade mitigation techniques include: power control, diversity, adaptive coding, and resource sharing. The Advanced Communications Technology Satellite (ACTS) provides an excellent opportunity to develop and test Ka-band rain impairment amelioration techniques. Up-link power control and diversity are discussed in this paper.

  17. Computational Design of Flat-Band Material

    Science.gov (United States)

    Hase, I.; Yanagisawa, T.; Kawashima, K.

    2018-02-01

    Quantum mechanics states that hopping integral between local orbitals makes the energy band dispersive. However, in some special cases, there are bands with no dispersion due to quantum interference. These bands are called as flat band. Many models having flat band have been proposed, and many interesting physical properties are predicted. However, no real compound having flat band has been found yet despite the 25 years of vigorous researches. We have found that some pyrochlore oxides have quasi-flat band just below the Fermi level by first principles calculation. Moreover, their valence bands are well described by a tight-binding model of pyrochlore lattice with isotropic nearest neighbor hopping integral. This model belongs to a class of Mielke model, whose ground state is known to be ferromagnetic with appropriate carrier doping and on-site repulsive Coulomb interaction. We have also performed a spin-polarized band calculation for the hole-doped system from first principles and found that the ground state is ferromagnetic for some doping region. Interestingly, these compounds do not include magnetic element, such as transition metal and rare-earth elements.

  18. Reward banding to determine reporting rate of recovered mourning dove bands

    Science.gov (United States)

    Tomlinson, R.E.

    1968-01-01

    Reward bands placed on the other leg of certain regularly banded immature mourning doves (Zenaidura macroura) were used to develop information on reporting rates of recovered dove bands. Reports from 15 widely separated sections of the United States showed considerable variation in recovery rate of doves both with and without reward bands. The overall percentages of banded doves that were reported as recovered were 9.69% for those with reward bands and 3.83% for controls. The bandreporting rate for states influenced by publicity was 66%; that for states not influenced was 32%.

  19. The True Story and Advantages of RNA Phage Capsids as Nanotools.

    Science.gov (United States)

    Pumpens, Paul; Renhofa, Regina; Dishlers, Andris; Kozlovska, Tatjana; Ose, Velta; Pushko, Peter; Tars, Kaspars; Grens, Elmars; Bachmann, Martin F

    2016-01-01

    RNA phages are often used as prototypes for modern recombinant virus-like particle (VLP) technologies. Icosahedral RNA phage VLPs can be formed from coat proteins (CPs) and are efficiently produced in bacteria and yeast. Both genetic fusion and chemical coupling have been successfully used for the production of numerous chimeras based on RNA phage VLPs. In this review, we describe advances in RNA phage VLP technology along with the history of the Leviviridae family, including its taxonomical organization, genomic structure, and important role in the development of molecular biology. Comparative 3D structures of different RNA phage VLPs are used to explain the level of VLP tolerance to foreign elements displayed on VLP surfaces. We also summarize data that demonstrate the ability of CPs to tolerate different organic (peptides, oligonucleotides, and carbohydrates) and inorganic (metal ions) compounds either chemically coupled or noncovalently added to the outer and/or inner surfaces of VLPs. Finally, we present lists of nanotechnological RNA phage VLP applications, such as experimental vaccines constructed by genetic fusion and chemical coupling methodologies, nanocontainers for targeted drug delivery, and bioimaging tools. © 2016 S. Karger AG, Basel.

  20. Gastric band slippage: a case-controlled study comparing new and old radiographic signs of this important surgical complication.

    Science.gov (United States)

    Swenson, David W; Pietryga, Jason A; Grand, David J; Chang, Kevin J; Murphy, Brian L; Egglin, Thomas K

    2014-07-01

    The purpose of this study was to compare the diagnostic performance of four radiographic signs of gastric band slippage: abnormal phi angle, the "O sign," inferior displacement of the superolateral gastric band margin, and presence of an air-fluid level above the gastric band. A search of the electronic medical record identified 21 patients with a surgically proven slipped gastric band and 63 randomly-selected asymptomatic gastric band patients who had undergone barium swallow studies. These studies were evaluated for the four signs of band slippage by two independent radiologists who were blinded to clinical data. Sensitivity, specificity, and positive and negative predictive values were calculated for each radiographic sign of band slippage. Interobserver agreement between radiologists was assessed using the Fleiss kappa statistic. In evaluating for gastric band slippage, an abnormal phi angle greater than 58° was 91-95% sensitive and 52-62% specific (κ = 0.78), the O sign was 33-48% sensitive but 97% specific (κ = 0.84), inferior displacement of the superolateral band margin by more than 2.4 cm from the diaphragm was 95% sensitive and 97-98% specific (κ = 0.97), and the presence of an air-fluid level was 95% sensitive and 100% specific (κ = 1.00). We report two previously undescribed radiographic signs of gastric band slippage that are both sensitive and specific for this important surgical complication and recommend that these signs should be incorporated into the imaging evaluation of gastric band patients.

  1. Solid State KA-Band, Solid State W-Band and TWT Amplifiers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Phase I of the proposal describes plans to develop a state of the art transmitter for the W-Band and KA -Band Cloud Radar system. Our focus will be concentrated in...

  2. Multiple band structure in 156Er

    International Nuclear Information System (INIS)

    Sunyar, A.W.; Der Mateosian, E.; Kistner, O.C.; Johnson, A.; Lumpkin, A.H.; Thieberger, P.

    1976-01-01

    The 142 Nd( 18 O,4n) 156 Er reaction at 90-95 MeV was used to study 156 Er high-spin states to spin 24. In addition to the background ground-state band, two well developed off-spin side bands, one of each parity, were observed. (Auth.)

  3. 47 CFR 90.1213 - Band plan.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Band plan. 90.1213 Section 90.1213 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND... § 90.1213 Band plan. The following channel center frequencies are permitted to be aggregated for...

  4. Signature effects in 2-qp rotational bands

    International Nuclear Information System (INIS)

    Jain, A.K.; Goel, A.

    1992-01-01

    The authors briefly review the progress in understanding the 2-qp rotational bands in odd-odd nuclei. Signature effects and the phenomenon of signature inversion are discussed. The Coriolis coupling appears to have all the ingredients to explain the inversion. Some recent work on signature dependence in 2-qp bands of even-even nuclei is also discussed; interesting features are pointed out

  5. Does the chromatic Mach bands effect exist?

    Science.gov (United States)

    Tsofe, Avital; Spitzer, Hedva; Einav, Shmuel

    2009-06-30

    The achromatic Mach bands effect is a well-known visual illusion, discovered over a hundred years ago. This effect has been investigated thoroughly, mainly for its brightness aspect. The existence of Chromatic Mach bands, however, has been disputed. In recent years it has been reported that Chromatic Mach bands are not perceived under controlled iso-luminance conditions. However, here we show that a variety of Chromatic Mach bands, consisting of chromatic and achromatic regions, separated by a saturation ramp, can be clearly perceived under iso-luminance and iso-brightness conditions. In this study, observers' eye movements were recorded under iso-brightness conditions. Several observers were tested for their ability to perceive the Chromatic Mach bands effect and its magnitude, across different cardinal and non-cardinal Chromatic Mach bands stimuli. A computational model of color adaptation, which predicted color induction and color constancy, successfully predicts this variation of Chromatic Mach bands. This has been tested by measuring the distance of the data points from the "achromatic point" and by calculating the shift of the data points from predicted complementary lines. The results suggest that the Chromatic Mach bands effect is a specific chromatic induction effect.

  6. Low band gap polymers for organic photovoltaics

    DEFF Research Database (Denmark)

    Bundgaard, Eva; Krebs, Frederik C

    2007-01-01

    Low band gap polymer materials and their application in organic photovoltaics (OPV) are reviewed. We detail the synthetic approaches to low band gap polymer materials starting from the early methodologies employing quinoid homopolymer structures to the current state of the art that relies...

  7. Band mixing in /sup 160/Dy

    Energy Technology Data Exchange (ETDEWEB)

    Hasiza, M L; Singh, K; Sahota, H S [Punjabi Univ., Patiala (India). Dept. of Physics

    1982-11-01

    The intensities of the gamma transitions in /sup 160/Dy have been measured precisely by a 45 cc Ge(Li) detector. Unequal quadrupole moments for the ground and gamma vibrational bands have been proposed in order to remove the inconsistencies in the values of band mixing parameter Z sub(gamma) for this doubly even deformed nucleus of /sup 160/Dy.

  8. Convex Banding of the Covariance Matrix.

    Science.gov (United States)

    Bien, Jacob; Bunea, Florentina; Xiao, Luo

    2016-01-01

    We introduce a new sparse estimator of the covariance matrix for high-dimensional models in which the variables have a known ordering. Our estimator, which is the solution to a convex optimization problem, is equivalently expressed as an estimator which tapers the sample covariance matrix by a Toeplitz, sparsely-banded, data-adaptive matrix. As a result of this adaptivity, the convex banding estimator enjoys theoretical optimality properties not attained by previous banding or tapered estimators. In particular, our convex banding estimator is minimax rate adaptive in Frobenius and operator norms, up to log factors, over commonly-studied classes of covariance matrices, and over more general classes. Furthermore, it correctly recovers the bandwidth when the true covariance is exactly banded. Our convex formulation admits a simple and efficient algorithm. Empirical studies demonstrate its practical effectiveness and illustrate that our exactly-banded estimator works well even when the true covariance matrix is only close to a banded matrix, confirming our theoretical results. Our method compares favorably with all existing methods, in terms of accuracy and speed. We illustrate the practical merits of the convex banding estimator by showing that it can be used to improve the performance of discriminant analysis for classifying sound recordings.

  9. Atomic-Monolayer MoS2 Band-to-Band Tunneling Field-Effect Transistor

    KAUST Repository

    Lan, Yann Wen

    2016-09-05

    The experimental observation of band-to-band tunneling in novel tunneling field-effect transistors utilizing a monolayer of MoS2 as the conducting channel is demonstrated. Our results indicate that the strong gate-coupling efficiency enabled by two-dimensional materials, such as monolayer MoS2, results in the direct manifestation of a band-to-band tunneling current and an ambipolar transport.

  10. Energy correlations for mixed rotational bands

    International Nuclear Information System (INIS)

    Doessing, T.

    1985-01-01

    A schematic model for the mixing of rotational bands above the yrast line in well deformed nuclei is considered. Many-particle configurations of a rotating mean field form basis bands, and these are subsequently mixed due to a two body residual interaction. The energy interval over which a basis band is spread out increases with increasing excitation energy above the yrast line. Conversely, the B(E2) matrix element for rotational decay out of one of the mixed band states is spread over an interval which is predicted to become more narrow with increasing excitation energy. Finally, the implication of band mixing for γ-ray energy correlations is briefly discussed. (orig.)

  11. Fluctuation diamagnetism in two-band superconductors

    Science.gov (United States)

    Adachi, Kyosuke; Ikeda, Ryusuke

    2016-04-01

    Anomalously large fluctuation diamagnetism around the superconducting critical temperature has been recently observed in iron selenide (FeSe) [Kasahara et al. (unpublished)]. This indicates that superconducting fluctuations (SCFs) play a more significant role in FeSe, which supposedly has a two-band structure, than in the familiar single-band superconductors. Motivated by the data on FeSe, SCF-induced diamagnetism is examined in a two-band system, on the basis of a phenomenological approach with a Ginzburg-Landau functional. The obtained results indicate that the SCF-induced diamagnetism may be more enhanced than that in a single-band system due to the existence of two distinct fluctuation modes. Such enhancement of diamagnetism unique to a two-band system seems consistent with the large diamagnetism observed in FeSe, though still far from a quantitative agreement.

  12. Design of a side-band-separating heterodyne mixer for band 9 of ALMA

    NARCIS (Netherlands)

    Baryshev, AM; Kooi, J; Mena, FR; Lodewijk, CRJ; Wild, W

    2005-01-01

    A side-band-separating (SBS) heterodyne mixer has been designed for the Atacama Large Millimeter Array (ALMA) 602-720 GHz band, as it will present a great improvement over the current double-side-band configuration under development at the moment. Here we present design details and the results of

  13. Life test on indigenous s-band pulsed magnetron

    International Nuclear Information System (INIS)

    Wanmode, Y.D.; Shrivastava, P.; Hannurkar, P.R.

    1999-01-01

    A 2 MW S-band pulsed magnetron has been developed under joint collaboration between CAT and CEERI. In this development effort several lab prototypes were evaluated on 2 MW microwave test facility developed at CAT. One magnetron is subjected to life test. The present paper describes the setup and procedures used for life test. Various observations and corrections made during the life tests are also described. Results of the tests are discussed. (author)

  14. Absorption band Q model for the earth

    International Nuclear Information System (INIS)

    Anderson, D.L.; Given, J.W.

    1982-01-01

    Body wave, surface wave, and normal mode data are used to place constraints on the frequency dependence of Q in the mantle. With a simple absorption band model it is possible to satisfy the shear sensitive data over a broad frequency range. The quality factor Q/sub s/(ω) is proportional to ω/sup α/ in the band and to ω and ω -1 at higher and lower frequencies, respectively, as appropriate for a relaxation mechanism with a spectrum of relaxation time. The parameters of the band are Q(min) = 80, α = 0.15, and width, 5 decades. The center of the band varies from 10 1 seconds in the upper mantle, to 1.6 x 10 3 seconds in the lower mantle. The shift of the band with depth is consistent with the expected effects of temperature, pressure and stress. High Q, regions of the mantle are attributed to a shift of the absorption band to longer periods. To satisfy the gravest fundamental spheroidal modes and the ScS data, the absorption band must shift back into the short-period seismic band at the base of the mantle. This may be due to a high temperature gradient or high shear stresses. A preliminary attempt is also made to specify bulk dissipation in the mantle and core. Specific features of the absorption band model are low Q in the body wave band at both the top and the base of the mantle, low Q for long-period body waves in the outer core, an inner core Q 2 that increases with period, and low Q/sub p//Q/sub s/ at short periods in the middle mantel. The short-period Q/sub s/ increases rapidly at 400 km and is relatively constant from this depth to 2400 km. The deformational Q of the earth at a period of 14 months is predicted to be 463

  15. Band-type microelectrodes for amperometric immunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ga-Yeon; Chang, Young Wook; Ko, Hyuk [Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-749 (Korea, Republic of); Kang, Min-Jung [Korea Institute of Science and Technology (KIST), Seoul (Korea, Republic of); Pyun, Jae-Chul, E-mail: jcpyun@yonsei.ac.kr [Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-749 (Korea, Republic of)

    2016-07-20

    A band-type microelectrode was made using a parylene-N film as a passivation layer. A circular-type, mm-scale electrode with the same diameter as the band-type microelectrode was also made with an electrode area that was 5000 times larger than the band-type microelectrode. By comparing the amperometric signals of 3,5,3′,5′-tetramethylbenzidine (TMB) samples at different optical density (OD) values, the band-type microelectrode was determined to be 9 times more sensitive than the circular-type electrode. The properties of the circular-type and the band-type electrodes (e.g., the shape of their cyclic voltammograms, the type of diffusion layer used, and the diffusion layer thickness per unit electrode area) were characterized according to their electrode area using the COMSOL Multiphysics software. From these simulations, the band-type electrode was estimated to have the conventional microelectrode properties, even when the electrode area was 100 times larger than a conventional circular-type electrode. These results show that both the geometry and the area of an electrode can influence the properties of the electrode. Finally, amperometric analysis based on a band-type electrode was applied to commercial ELISA kits to analyze human hepatitis B surface antigen (hHBsAg) and human immunodeficiency virus (HIV) antibodies. - Highlights: • A band-type microelectrode was made using a parylene-N film as a passivation layer. • The band-type microelectrode was 14-times more sensitive than circular-type electrode. • The influence of geometry on microelectrode properties was simulated using COMSOL. • The band-type electrode was applied to ELISA kits for hHBsAg and hHIV-antibodies.

  16. Comparison of retention and demineralization inhibition potential of adhesive banding cements in primary teeth.

    Science.gov (United States)

    Prabhakar, A R; Mahantesh, T; Ahuja, Vipin

    2010-01-01

    The purpose of this study was to evaluate the efficacy of banding cements in terms of retentive capability and demineralization inhibition potential. We included 48 non-carious primary mandibular second molar teeth. Preformed stainless steel bands were adapted onto the teeth. All teeth were randomly assigned to four groups: Group I (Adaptation of bands without cementation), Group II (Cementation of bands using conventional Glass Ionomer Cement), Group III (Cementation of bands using Resin-modified Glass Ionomer Cement), Group IV (Cementation of bands using Resin cement), and placed in artificial saliva. Each day, specimens were taken from artificial saliva and suspended in an artificial caries solution for 35 minutes, every 8 hours. At the end of 3 months, retention of bands was estimated using an Instron Universal Testing Machine. The mode of failure was recorded and specimens were sectioned and examined under polarized microscope for demineralized lesions. The mean retention value was highest with resin cement, followed by RMGIC, GIC, and Control group respectively. The RMGIC group showed more favorable modes of failures. All the experimental groups showed significant demineralization inhibition potential. RMGIC is the preferable banding cement and can be used effectively to cement bands in primary dentition.

  17. The HubBLe Trial: haemorrhoidal artery ligation (HAL) versus rubber band ligation (RBL) for symptomatic second- and third-degree haemorrhoids: a multicentre randomised controlled trial and health-economic evaluation.

    Science.gov (United States)

    Brown, Steven; Tiernan, Jim; Biggs, Katie; Hind, Daniel; Shephard, Neil; Bradburn, Mike; Wailoo, Allan; Alshreef, Abualbishr; Swaby, Lizzie; Watson, Angus; Radley, Simon; Jones, Oliver; Skaife, Paul; Agarwal, Anil; Giordano, Pasquale; Lamah, Marc; Cartmell, Mark; Davies, Justin; Faiz, Omar; Nugent, Karen; Clarke, Andrew; MacDonald, Angus; Conaghan, Phillip; Ziprin, Paul; Makhija, Rohit

    2016-11-01

    Optimal surgical intervention for low-grade haemorrhoids is unknown. Rubber band ligation (RBL) is probably the most common intervention. Haemorrhoidal artery ligation (HAL) is a novel alternative that may be more efficacious. The comparison of HAL with RBL for the treatment of grade II/III haemorrhoids. A multicentre, parallel-group randomised controlled trial. UK NHS and Personal Social Services. 17 NHS Trusts. Patients aged ≥ 18 years presenting with grade II/III (second- and third-degree) haemorrhoids, including those who have undergone previous RBL. HAL with Doppler probe compared with RBL. Primary outcome - recurrence at 1 year post procedure; secondary outcomes - recurrence at 6 weeks; haemorrhoid severity score; European Quality of Life-5 Dimensions, 5-level version (EQ-5D-5L); Vaizey incontinence score; pain assessment; complications; and cost-effectiveness. A total of 370 participants entered the trial. At 1 year post procedure, 30% of the HAL group had evidence of recurrence compared with 49% after RBL [adjusted odds ratio (OR) = 2.23, 95% confidence interval (CI) 1.42 to 3.51; p  = 0.0005]. The main reason for the difference was the number of extra procedures required to achieve improvement/cure. If a single HAL is compared with multiple RBLs then only 37.5% recurred in the RBL arm (adjusted OR 1.35, 95% CI 0.85 to 2.15; p  = 0.20). Persistence of significant symptoms at 6 weeks was lower in both arms than at 1 year (9% HAL and 29% RBL), suggesting significant deterioration in both groups over the year. Symptom score, EQ-5D-5L and Vaizey score improved in both groups compared with baseline, but there was no difference between interventions. Pain was less severe and of shorter duration in the RBL group; most of the HAL group who had pain had mild to moderate pain, resolving by 3 weeks. Complications were low frequency and not significantly different between groups. It appeared that HAL was not cost-effective compared with RBL. In the base

  18. Band structure studies of actinide systems

    International Nuclear Information System (INIS)

    Koelling, D.D.

    1976-01-01

    The nature of the f-orbitals in an actinide system plays a crucial role in determining the electronic properties. It has long been realized that when the actinide separation is small enough for the f-orbitals to interact directly, the system will exhibit itinerant electron properties: an absence of local moment due to the f-orbitals and sometimes even superconductivity. However, a number of systems with the larger actinide separation that should imply local moment behavior also exhibit intinerant properties. Such systems (URh 3 , UIr 3 , UGe 3 , UC) were examined to learn something about the other f-interactions. A preliminary observation made is that there is apparently a very large and ansiotropic mass enhancement in these systems. There is very good reason to believe that this is not solely due to large electron--electron correlations but to a large electron--phonon interaction as well. These features of the ''non-magnetic'', large actinide separation systems are discussed in light of our results to date. Finally, the results of some recent molecular calculations on actinide hexafluorides are used to illustrate the shielding effects on the intra-atomic Coulomb term U/sub f-f/ which would appear in any attempt to study the formation of local moments. As one becomes interested in materials for which a band structure is no longer an adequate model, this screened U/sub ff/ is the significant parameter and efforts must be made to evaluate it in solid state systems

  19. Microleakage under orthodontic bands cemented with nano-hydroxyapatite-modified glass ionomer.

    Science.gov (United States)

    Enan, Enas T; Hammad, Shaza M

    2013-11-01

    To estimate the in vivo effect of nano-hydroxyapatite (HA) modification of banding glass-ionomer cement on microleakage under orthodontic bands. Eighty noncarious premolars scheduled for extraction in 20 orthodontic patients were randomly divided into four groups. Grouping was based on the ratio of nano-HA (0%, 5%, 10%, 15% by weight) added to the luting glass-ionomer cement (GIC) Ketac-Cem, which was used for cementation of prefabricated micro-etched orthodontic bands. Dye penetration method was used for microleakage evaluation at the cement-band and cement-enamel interfaces. Statistical evaluation was performed with a Kruskal-Wallis test and a Mann-Whitney U-test, and a Bonferroni-adjusted significance level was calculated. Bands cemented with conventional GIC showed the highest microleakage scores in comparison to those cemented with nano-HA-modified GIC. No significant difference was found between teeth banded with 10% and 15% modified GIC. Modification of the banding GIC with 15% nano-HA revealed a positive effect on reducing microleakage around orthodontic bands.

  20. Two-band superconductor magnesium diboride

    International Nuclear Information System (INIS)

    Xi, X X

    2008-01-01

    This review focuses on the most important features of the 40 K superconductor MgB 2 -the weakly interacting multiple bands (the σ and π bands) and the distinct multiple superconducting energy gaps (the σ and π gaps). Even though the pairing mechanism of superconductor MgB 2 is the conventional electron-phonon coupling, the prominent influence of the two bands and two gaps on its properties sets it apart from other superconductors. It leads to markedly different behaviors in upper critical field, vortex structure, magnetoresistance and many other superconducting and normal-state properties in MgB 2 from single-band superconductors. Further, it gives rise to new physics that does not exist in single-band superconductors, such as the internal Josephson effects between the two order parameters. These unique phenomena depend sensitively on scattering inside and between the two bands, and the intraband and interband scattering can be modified by chemical substitution and irradiation. MgB 2 has brought unprecedented attention to two-band superconductivity, which has been found to exist in other old and new superconductors. The legacy of MgB 2 will be long lasting because of this, as well as the lessons it teaches in terms of the search for new phonon-mediated higher T c superconductors

  1. Dual-band frequency selective surface with large band separation and stable performance

    International Nuclear Information System (INIS)

    Zhou Hang; Qu Shao-Bo; Lin Bao-Qin; Wang Jia-Fu; Ma Hua; Zhang Jie-Qiu; Peng Wei-Dong; Bai Peng; Wang Xu-Hua; Xu Zhuo

    2012-01-01

    A new technique of designing a dual-band frequency selective surface with large band separation is presented. This technique is based on a delicately designed topology of L- and Ku-band microwave filters. The two band-pass responses are generated by a capacitively-loaded square-loop frequency selective surface and an aperture-coupled frequency selective surface, respectively. A Faraday cage is located between the two frequency selective surface structures to eliminate undesired couplings. Based on this technique, a dual-band frequency selective surface with large band separation is designed, which possesses large band separation, high selectivity, and stable performance under various incident angles and different polarizations. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  2. Asymmetric acoustic transmission in multiple frequency bands

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hong-xiang, E-mail: jsdxshx@ujs.edu.cn [Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013 (China); Laboratory of Modern Acoustics, Institute of Acoustics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093 (China); State Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190 (China); Yuan, Shou-qi, E-mail: Shouqiy@ujs.edu.cn [Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013 (China); Zhang, Shu-yi [Laboratory of Modern Acoustics, Institute of Acoustics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093 (China)

    2015-11-23

    We report both experimentally and numerically that the multi-band device of the asymmetric acoustic transmission is realized by placing two periodic gratings with different periods on both sides of two brass plates immersed in water. The asymmetric acoustic transmission can exist in four frequency bands below 1500 kHz, which arises from the interaction between various diffractions from the two gratings and Lamb modes in the brass plates immersed in water. The results indicate that the device has the advantages of multiple band, broader bandwidth, and simpler structure. Our finding should have great potential applications in ultrasonic devices.

  3. Asymmetric acoustic transmission in multiple frequency bands

    International Nuclear Information System (INIS)

    Sun, Hong-xiang; Yuan, Shou-qi; Zhang, Shu-yi

    2015-01-01

    We report both experimentally and numerically that the multi-band device of the asymmetric acoustic transmission is realized by placing two periodic gratings with different periods on both sides of two brass plates immersed in water. The asymmetric acoustic transmission can exist in four frequency bands below 1500 kHz, which arises from the interaction between various diffractions from the two gratings and Lamb modes in the brass plates immersed in water. The results indicate that the device has the advantages of multiple band, broader bandwidth, and simpler structure. Our finding should have great potential applications in ultrasonic devices

  4. Modification of Banding in Dual-Phase Steels via Thermal Processing

    DEFF Research Database (Denmark)

    Mukherjee, Krishnendu; Thomas, L. S.; Bos, C.

    2014-01-01

    The potential to utilize controlled thermal processing to minimize banding in a DP780 steel with 2 wt pct Mn was evaluated on samples processed on a Gleeble® 3500 thermomechanical processing simulator. All processing histories were selected to result in final dual-phase steel microstructures...... simulating microstructures achievable during annealing of initially cold rolled sheet. Strip samples were processed to evaluate the effects of heating rate, annealing time, annealing temperature, and cooling rate. The degree of banding in the final microstructures was evaluated with standard light optical...... microscopic techniques. Results are presented to illustrate that the extent of banding depended on control of both heating and cooling rates, and a specific processing history based on a two-stage heating rate can be used to minimize visible banding in selected final heat treated products....

  5. Validation of a novel laparoscopic adjustable gastric band simulator.

    Science.gov (United States)

    Sankaranarayanan, Ganesh; Adair, James D; Halic, Tansel; Gromski, Mark A; Lu, Zhonghua; Ahn, Woojin; Jones, Daniel B; De, Suvranu

    2011-04-01

    Morbid obesity accounts for more than 90,000 deaths per year in the United States. Laparoscopic adjustable gastric banding (LAGB) is the second most common weight loss procedure performed in the US and the most common in Europe and Australia. Simulation in surgical training is a rapidly advancing field that has been adopted by many to prepare surgeons for surgical techniques and procedures. The aim of our study was to determine face, construct, and content validity for a novel virtual reality laparoscopic adjustable gastric band simulator. Twenty-eight subjects were categorized into two groups (expert and novice), determined by their skill level in laparoscopic surgery. Experts consisted of subjects who had at least 4 years of laparoscopic training and operative experience. Novices consisted of subjects with medical training but with less than 4 years of laparoscopic training. The subjects used the virtual reality laparoscopic adjustable band surgery simulator. They were automatically scored according to various tasks. The subjects then completed a questionnaire to evaluate face and content validity. On a 5-point Likert scale (1 = lowest score, 5 = highest score), the mean score for visual realism was 4.00 ± 0.67 and the mean score for realism of the interface and tool movements was 4.07 ± 0.77 (face validity). There were significant differences in the performances of the two subject groups (expert and novice) based on total scores (p virtual reality laparoscopic adjustable gastric band simulator. Our initial results demonstrate excellent face, construct, and content validity findings. To our knowledge, this is the first virtual reality simulator with haptic feedback for training residents and surgeons in the laparoscopic adjustable gastric banding procedure.

  6. Frequency band analysis of muscle activation during cycling to exhaustion

    Directory of Open Access Journals (Sweden)

    Fernando Diefenthaeler

    2012-04-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p243 Lower limb muscles activation was assessed during cycling to exhaustion using frequency band analysis. Nine cyclists were evaluated in two days. On the first day, cyclists performed a maximal incremental cycling exercise to measure peak power output, which was used on the second day to define the workload for a constant load time to exhaustion cycling exercise (maximal aerobic power output from day 1. Muscle activation of vastus lateralis (VL, long head of biceps femoris (BF, lateral head of gastrocnemius (GL, and tibialis anterior (TA from the right lower limb was recorded during the time to exhaustion cycling exercise. A series of nine band-pass Butterworth digital filters was used to analyze muscle activity amplitude for each band. The overall amplitude of activation and the high and low frequency components were defined to assess the magnitude of fatigue effects on muscle activity via effect sizes. The profile of the overall muscle activation during the test was analyzed using a second order polynomial, and the variability of the overall bands was analyzed by the coefficient of variation for each muscle in each instant of the test. Substantial reduction in the high frequency components of VL and BF activation was observed. The overall and low frequency bands presented trivial to small changes for all muscles. High relationship between the second order polynomial fitting and muscle activity was found (R2 > 0.89 for all muscles. High variability (~25% was found for muscle activation at the four instants of the fatigue test. Changes in the spectral properties of the EMG signal were only substantial when extreme changes in fatigue state were induced.

  7. Multi-spectral band selection for satellite-based systems

    International Nuclear Information System (INIS)

    Clodius, W.B.; Weber, P.G.; Borel, C.C.; Smith, B.W.

    1998-01-01

    The design of satellite based multispectral imaging systems requires the consideration of a number of tradeoffs between cost and performance. The authors have recently been involved in the design and evaluation of a satellite based multispectral sensor operating from the visible through the long wavelength IR. The criteria that led to some of the proposed designs and the modeling used to evaluate and fine tune the designs will both be discussed. These criteria emphasized the use of bands for surface temperature retrieval and the correction of atmospheric effects. The impact of cost estimate changes on the final design will also be discussed

  8. gamma-induced modification on optical band gap of CR-39 SSNTD

    International Nuclear Information System (INIS)

    Zaki, M.F.

    2010-01-01

    effect of gamma irradiation on optical absorption of nuclear track detectors like CR-39 was studied at different absorbed doses using ultraviolet-visible (UV-VIS)spectroscopy. the existence of the peaks, their shifting and broadening as a result of gamma irradiation has been discussed. the width of the tail of localized states in the band gap (E u )was evaluated using the Urbach edge method. finally the indirect and direct band gap in pristine and gamma irradiated CR-39 have been determined. the values of indirect band gap have been found to be lower than the corresponding values of direct band gap. a decrease in the optical energy gap with increasing the gamma absorbed dose can be discussed on the basis of gamma-irradiation-induced defects in the CR-39. the correlation between optical band gap and the number of carbon atoms in a cluster with modified Tauc's equation has been discussed in case of CR-39.

  9. Observation of dipole bands in 144Sm

    International Nuclear Information System (INIS)

    Raut, R.; Ganguly, S.; Kshetri, R.; Banerjee, P.; Bhattacharya, S.; Dasmahapatra, B.; Mukherjee, A.; Sahasarkar, M.; Goswami, A.; Basu, S.K.; Bhattacharjee, T.; Mukherjee, G.; Chakraborty, A.; Ghughre, S.S.; Krishichayan; Mukhopadhyay, S.; Gangopadhyay, G.; Singh, A.K.

    2007-01-01

    The nucleus 144 Sm (Z=62, N=82), with its proximity to the shell closure and possibilities of particles and holes occupying high j orbitals, following appropriate excitations, is a suitable system for observation of dipole (MR) bands

  10. Silicone rubber band for laparoscopic tubal sterilization.

    Science.gov (United States)

    Ansari, A H; Sealey, R M; Gay, J W; Kang, I

    1977-12-01

    In 1974, Yoon and associates (Am J Obstet Gynecol 120:132, 1974) described a new approach in which laparoscopic tubal occlusion was accomplished by utilizing the silicone rubber band technique. Recognizing the great advantages of the new technique in eliminating potential thermal injury associated with electrocoagulation, the authors have utilized the Yoon silicone rubber band technique in these institutions over the past 20 months. Thus far the procedure has been performed in 304 patients without any major complications. In the hope of eliminating and/or reducing possible pregnancy-failure rates, in 110 cases. In addition to application of the silicone band, the tube within the band was transected with non-electrical Seigler biopsy forceps. This, we believe, should provide an interesting long-term comparative study.

  11. Microbial processes in banded iron formation deposition

    DEFF Research Database (Denmark)

    Posth, Nicole; Konhauser, Kurt; Kappler, Andreas

    2013-01-01

    , remains unresolved. Evidence of an anoxic Earth with only localized oxic areas until the Great Oxidation Event ca 2·45 to 2·32 Ga makes the investigation of O2-independent mechanisms for banded iron formation deposition relevant. Recent studies have explored the long-standing proposition that Archean......Banded iron formations have been studied for decades, particularly regarding their potential as archives of the Precambrian environment. In spite of this effort, the mechanism of their deposition and, specifically, the role that microbes played in the precipitation of banded iron formation minerals...... banded iron formations may have been formed, and diagenetically modified, by anaerobic microbial metabolisms. These efforts encompass a wide array of approaches including isotope, ecophysiological and phylogeny studies, molecular and mineral marker analysis, and sedimentological reconstructions. Herein...

  12. Simulating Precambrian banded iron formation diagenesis

    DEFF Research Database (Denmark)

    Posth, Nicole R.; K??hler, Inga; D. Swanner, Elizabeth

    2013-01-01

    Post-depositional diagenetic alteration makes the accurate interpretation of key precipitation processes in ancient sediments, such as Precambrian banded iron formations (BIFs), difficult. While microorganisms are proposed as key contributors to BIF deposition, the diagenetic transformation...

  13. The Novel Microwave Stop-Band Filter

    Directory of Open Access Journals (Sweden)

    R. E. Chernobrovkin

    2008-01-01

    Full Text Available The stop-band filter with the new band-rejection element is proposed. The element is a coaxial waveguide with the slot in the centre conductor. In the frame of this research, the numerical and experimental investigations of the amplitude-frequency characteristics of the filter are carried out. It is noted that according to the slot parameters the two typical resonances (half-wave and quarter-wave can be excited. The rejection band of the single element is defined by the width, depth, and dielectric filling of the slot. Fifth-order Chebyshev filter utilizing the aforementioned element is also synthesized, manufactured, and tested. The measured and simulated results are in good agreement. The experimental filter prototype exhibits the rejection band 0.86 GHz at the level −40 dB.

  14. Experimental study on the adiabatic shear bands

    International Nuclear Information System (INIS)

    Affouard, J.

    1984-07-01

    Four martensitic steels (Z50CDV5 steel, 28CND8 steel, 35NCDV16 steel and 4340 steel) with different hardness between 190 and 600 Hsub(B) (Brinell hardness), have been studied by means of dynamic compressive tests on split Hopkinson pressure bar. Microscopic observations show that the fracture are associated to the development of adiabatic shear bands (except 4340 steel with 190 Hsub(B) hardness). By means of tests for which the deformation is stopped at predetermined levels, the measurement of shear and hardness inside the band and the matrix indicates the chronology of this phenomenon: first the localization of shear, followed by the formation of adiabatic shear band and ultimatly crack initiation and propagation. These results correlated with few simulations by finite elements have permitted to suggest two mecanisms of deformation leading to the formation of adiabatic shear bands in this specific test [fr

  15. The cellular approach to band structure calculations

    International Nuclear Information System (INIS)

    Verwoerd, W.S.

    1982-01-01

    A short introduction to the cellular approach in band structure calculations is given. The linear cellular approach and its potantial applicability in surface structure calculations is given some consideration in particular

  16. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2001-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  17. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2003-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  18. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2002-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  19. Deployable Ka-Band Reflectarray, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Tyvak, in collaboration with UCLA, proposes a novel approach to the challenge of creating a large reflector for Ka-band high data rate links. We propose to attach...

  20. Confidence bands for inverse regression models

    International Nuclear Information System (INIS)

    Birke, Melanie; Bissantz, Nicolai; Holzmann, Hajo

    2010-01-01

    We construct uniform confidence bands for the regression function in inverse, homoscedastic regression models with convolution-type operators. Here, the convolution is between two non-periodic functions on the whole real line rather than between two periodic functions on a compact interval, since the former situation arguably arises more often in applications. First, following Bickel and Rosenblatt (1973 Ann. Stat. 1 1071–95) we construct asymptotic confidence bands which are based on strong approximations and on a limit theorem for the supremum of a stationary Gaussian process. Further, we propose bootstrap confidence bands based on the residual bootstrap and prove consistency of the bootstrap procedure. A simulation study shows that the bootstrap confidence bands perform reasonably well for moderate sample sizes. Finally, we apply our method to data from a gel electrophoresis experiment with genetically engineered neuronal receptor subunits incubated with rat brain extract

  1. Modification in band gap of zirconium complexes

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Mayank, E-mail: mayank30134@gmail.com; Singh, J.; Chouhan, S. [Department of Physics, ISLE, IPS Academy, Indore (M.P.) (India); Mishra, A. [School of Physics, Devi Ahilya Vishwavidyalaya, Indore (M.P.) (India); Shrivastava, B. D. [Govt. P. G. College, Biora (M.P.) (India)

    2016-05-06

    The optical properties of zirconium complexes with amino acid based Schiff bases are reported here. The zirconium complexes show interesting stereo chemical features, which are applicable in organometallic and organic synthesis as well as in catalysis. The band gaps of both Schiff bases and zirconium complexes were obtained by UV-Visible spectroscopy. It was found that the band gap of zirconium complexes has been modified after adding zirconium compound to the Schiff bases.

  2. Theoretical Prediction of the Forming Limit Band

    International Nuclear Information System (INIS)

    Banabic, D.; Paraianu, L.; Vos, M.; Jurco, P.

    2007-01-01

    Forming Limit Band (FLB) is a very useful tool to improve the sheet metal forming simulation robustness. Until now, the study of the FLB was only experimental. This paper presents the first attempt to model the FLB. The authors have established an original method for predicting the two margins of the limit band. The method was illustrated on the AA6111-T43 aluminum alloy. A good agreement with the experiments has been obtained

  3. Theoretical Prediction of the Forming Limit Band

    Science.gov (United States)

    Banabic, D.; Vos, M.; Paraianu, L.; Jurco, P.

    2007-04-01

    Forming Limit Band (FLB) is a very useful tool to improve the sheet metal forming simulation robustness. Until now, the study of the FLB was only experimental. This paper presents the first attempt to model the FLB. The authors have established an original method for predicting the two margins of the limit band. The method was illustrated on the AA6111-T43 aluminum alloy. A good agreement with the experiments has been obtained.

  4. Home-use cancer detecting band aid

    Science.gov (United States)

    Zalevsky, Zeev; Rudnitsky, Arkady; Sheinman, Victor; Tzoy, Andrey; Toktosunov, Aitmamat; Adashov, Arkady

    2016-03-01

    In this paper we present a novel concept in which special band aid is developed for early detection of cancer. The band aid contains an array of micro needles with small detection array connected to each needle which inspects the color of the surface of the skin versus time after being pinched with the needles. We were able to show in pre-clinical trials that the color varies differently if the skin is close to tumor tissue.

  5. A superdeformed band in {sup 142}Sm

    Energy Technology Data Exchange (ETDEWEB)

    Hackman, G; Mullins, J M; Kuehner, J A; Prevost, D; Waddington, J C [McMaster Univ., Hamilton, ON (Canada). Dept. of Physics; Galindo-Uribarri, A; Janzen, V P; Radford, D C; Schmeing, N; Ward, D [Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.

    1992-08-01

    Observation of {gamma}-{gamma} coincidences from the reaction {sup 124}Sn({sup 24}Mg,6n){sup 142}Sm at 145 MeV indicates the existence of a rotational band with dynamic moment of inertia J{sup (2)} similar to that of the superdeformed band in the isotone {sup 143}Eu. This result is consistent with calculations predicting superdeformed structures in N = 80, Z {approx} 64 nuclei. (author). 8 refs., 4 figs.

  6. Band structures in near spherical 138Ce

    Science.gov (United States)

    Bhattacharjee, T.; Chanda, S.; Bhattacharyya, S.; Basu, S. K.; Bhowmik, R. K.; Das, J. J.; Pramanik, U. Datta; Ghugre, S. S.; Madhavan, N.; Mukherjee, A.; Mukherjee, G.; Muralithar, S.; Singh, R. P.

    2009-06-01

    The high spin states of N=80138Ce have been populated in the fusion evaporation reaction 130Te( 12C, 4n) 138Ce at E=65 MeV. The γ transitions belonging to various band structures were detected and characterized using an array of five Clover Germanium detectors. The level scheme has been established up to a maximum spin and excitation energy of 23 ℏ and 9511.3 keV, respectively, by including 53 new transitions. The negative parity ΔI=1 band, developed on the 6536.3 keV 15 level, has been conjectured to be a magnetic rotation band following a semiclassical analysis and comparing the systematics of similar bands in the neighboring nuclei. The said band is proposed to have a four quasiparticle configuration of [πgh]⊗[. Other band structures are interpreted in terms of multi-quasiparticle configurations, based on Total Routhian Surface (TRS) calculations. For the low and medium spin states, a shell model calculation using a realistic two body interaction has been performed using the code OXBASH.

  7. Electron correlations in narrow band systems

    International Nuclear Information System (INIS)

    Kishore, R.

    1983-01-01

    The effect of the electron correlations in narrow bands, such as d(f) bands in the transition (rare earth) metals and their compounds and the impurity bands in doped semiconductors is studied. The narrow band systems is described, by the Hubbard Hamiltonian. By proposing a local self-energy for the interacting electron, it is found that the results are exact in both atomic and band limits and reduce to the Hartree Fock results for U/Δ → 0, where U is the intra-atomic Coulomb interaction and Δ is the bandwidth of the noninteracting electrons. For the Lorentzian form of the density of states of the noninteracting electrons, this approximation turns out to be equivalent to the third Hubbard approximation. A simple argument, based on the mean free path obtained from the imaginary part of the self energy, shows how the electron correlations can give rise to a discontinous metal-nonmetal transition as proposed by Mott. The band narrowing and the existence of the satellite below the Fermi energy in Ni, found in photoemission experiments, can also be understood. (Author) [pt

  8. Double Cortex Syndrome (Subcortical Band Heterotopia): A Case Report.

    Science.gov (United States)

    Momen, Ali Akbar; Momen, Mehdi

    2015-01-01

    Objective Approximately 5-10% of preschool age children are considered developmentally disabled. Brain Magnetic Resonance Imaging (MRI) plays a key role in the diagnostic evaluation in these children. Many congenital or acquired brain anomalies are revealed with MRIs. Although the majority of these abnormalities are sporadic but patients with subcortical band heterotopia or double cortex syndrome have sex-linked inheritance. We are going to present the first case in Iran from Ahvaz city, which was presented with status epilepticus associated with developmental delay and finally diagnosed as double cortex syndrome, because band heterotopia cases especially for continuous or generalized form is rare. A 4.5-year-old developmentally delayed girl was admitted for generalized tonic clonic seizure attack of 1 hr, upward gaze, locked mouth, and urinary incontinence (status epilepticus) in the child neurology ward. She had a history of recurrent seizures that started as febrile seizures since she was 12 months of age and had frequent admissions for having recurrent seizure attacks. She was the only child of consanguineous parents with negative family history of any neurologic problems. She was a product of uneventful term pregnancy, vaginal delivery with a low Apgar score at birth who was admitted for six days in the neonatal ward for hypotonia and cyanosis. At 4.5 years of age, she had HC: 45cm (spike-wave discharges. A brain MRI showed corpus callosal dysplasia, generalized band heterotopia, and polymicrogyria. She was discharged home with oral valproate and regular outpatient follow-ups. In the diagnostic evaluation of developmentally delayed and epileptic children, a brain MRI is strongly recommended for accurate diagnosis of anomalies such as neuronal migration disorders (band heterotopia) and others, because appropriate therapeutic management, prognosis, prevention, and genetic counseling for prenatal diagnosis are dependent on definite diagnosis of the proband case.

  9. Metal-like Band Structures of Ultrathin Si {111} and {112} Surface Layers Revealed through Density Functional Theory Calculations.

    Science.gov (United States)

    Tan, Chih-Shan; Huang, Michael H

    2017-09-04

    Density functional theory calculations have been performed on Si (100), (110), (111), and (112) planes with tunable number of planes for evaluation of their band structures and density of states profiles. The purpose is to see whether silicon can exhibit facet-dependent properties derived from the presence of a thin surface layer having different band structures. No changes have been observed for single to multiple layers of Si (100) and (110) planes with a consistent band gap between the valence band and the conduction band. However, for 1, 2, 4, and 5 Si (111) and (112) planes, metal-like band structures were obtained with continuous density of states going from the valence band to the conduction band. For 3, 6, and more Si (111) planes, as well as 3 and 6 Si (112) planes, the same band structure as that seen for Si (100) and (110) planes has been obtained. Thus, beyond a layer thickness of five Si (111) planes at ≈1.6 nm, normal semiconductor behavior can be expected. The emergence of metal-like band structures for the Si (111) and (112) planes are related to variation in Si-Si bond length and bond distortion plus 3s and 3p orbital electron contributions in the band structure. This work predicts possession of facet-dependent electrical properties of silicon with consequences in FinFET transistor design. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Hyperspectral band selection and classification of Hyperion image of Bhitarkanika mangrove ecosystem, eastern India

    Science.gov (United States)

    Ashokkumar, L.; Shanmugam, S.

    2014-10-01

    identified and the health status of these species are assessed by the selected band. Further, the performance of this band selection approaches are evaluated in multi-sensor image fusion for better mapping of mangrove ecosystems, wherein spatial resolution is enhanced while retaining the optimal number of hyperspectral bands.

  11. B(M1) values in the band-crossing of shears bands in 197Pb

    Science.gov (United States)

    Krücken, R.; Cooper, J. R.; Beausang, C. W.; Novak, J. R.; Dewald, A.; Klug, T.; Kemper, G.; von Brentano, P.; Carpenter, M.; Wiedenhöver, I.

    We present details of the band crossing mechanism of shears bands using the example of 197Pb. Absolute reduced matrix elements B(M1) were determined by means of a RDM lifetime measurement in one of the shears bands in 197Pb. The experiment was performed using the New Yale Plunger Device (NYPD) in conjunction with the Gammasphere array. Band mixing calculations on the basis of the semi-classical model of the shears mechanism are used to describe the transition matrix elements B(M1) and energies throughout the band-crossing regions. Good agreement with the data was obtained and the detailed composition of the states in the shears band are discussed.

  12. ISM band to U-NII band frequency transverter and method of frequency transversion

    Science.gov (United States)

    Stepp, Jeffrey David [Grandview, MO; Hensley, Dale [Grandview, MO

    2006-09-12

    A frequency transverter (10) and method for enabling bi-frequency dual-directional transfer of digitally encoded data on an RF carrier by translating between a crowded or otherwise undesirable first frequency band, such as the 2.4 GHz ISM band, and a less-crowded or otherwise desirable second frequency band, such as the 5.0 GHz 6.0 GHz U-NII band. In a preferred embodiment, the transverter (10) connects between an existing data radio (11) and its existing antenna (30), and comprises a bandswitch (12); an input RF isolating device (14); a transmuter (16); a converter (18); a dual output local oscillator (20); an output RF isolating device (22); and an antenna (24) tuned to the second frequency band. The bandswitch (12) allows for bypassing the transverter (10), thereby facilitating its use with legacy systems. The transmuter (14) and converter (16) are adapted to convert to and from, respectively, the second frequency band.

  13. Electronic structure of the copper oxides: Band picture versus correlated behavior

    Energy Technology Data Exchange (ETDEWEB)

    Pickett, W E; Cohen, R E; Singh, D [Naval Research Lab., Washington, DC (USA); Krakauer, H [Coll. of William and Mary, Williamsburg, VA (USA)

    1989-12-01

    In the 2 1/2 years since the discovery of the high temperature superconducting copper oxides, a great deal has been learned from experiment about their behavior. From the theoretical side, there continues to be developments both within the band picture and from the model Hamiltonian viewpoint emphasizing correlations. In this paper we discuss briefly these complementary viewpoints in relation to certain of the experimental data. Due to our background in the band structure area, we approach the discussion by evaluating which phenomena can be (or has been) accounted for by the standard band approach, and point out which properties appear to require more intricate treatments of correlation. (orig.).

  14. Effects of band-steaming on microbial activity and abundance in organic farming soil

    DEFF Research Database (Denmark)

    Elsgaard, Lars; Jørgensen, Martin Heide; Elmholt, Susanne

    2010-01-01

    Band-steaming of arable soil at 80-90 ◦C kill off weed seeds prior to crop establishment which allows an extensive intra-row weed control. Here we evaluated the side-effects of in situ band-steaming on soil respiration, enzyme activities, and numbers of culturable bacteria and fungi in an organic...... insignificant or slightly stimulatory (P recovery during 90 days after band-steaming. Bacterial colony-forming units increased after soil steaming...... whereas the number of fungal propagules was reduced by 50% (P recovery potential...

  15. Determination of density of band-gap states of hydrogenated amorphous silicon suboxide thin films

    International Nuclear Information System (INIS)

    Bacioglu, A.

    2005-01-01

    Variation of density of gap states of PECVD silicon suboxide films with different oxygen concentrations was evaluated through electrical and optical measurements. Optical transmission and constant photocurrent method (CPM) were used to determine absorption coefficient as a function of photon energy. From these measurements the localized density of states between the valance band mobility edge and Fermi level has been determined. To determine the variation of conduction band edge, steady state photoconductivity (SSPC), photoconductivity response time (PCRT) and transient photoconductivity (TPC) measurements were utilized. Results indicate that the conduction and valance band edges, both, widen monotonically with oxygen content

  16. Study of III-V semiconductor band structure by synchrotron photoemission

    International Nuclear Information System (INIS)

    Williams, G.P.; Cerrina, F.; Anderson, J.; Lapeyre, G.J.; Smith, R.J.; Hermanson, J.; Knapp, J.A.

    1982-01-01

    Angle-resolved synchrotron photoemission studies of six III-V semiconductors have been carried out. For emission normal to the (110) plane of these materials, peaks in the experimental spectra were identified with the bands involved in the transitions, and the critical point energies X 3 , X 5 , and Σ 1 /sup min/, were determined. The data indicate that k perpendicular is conserved in the transitions. Comparison of the data with theoretical bands permits an evaluation of k perpendicular associated with the experimentally observed transition, and from this information the bands were plotted out

  17. Parallelization of mathematical library for generalized eigenvalue problem for real band matrices

    International Nuclear Information System (INIS)

    Tanaka, Yasuhisa.

    1997-05-01

    This research has focused on a parallelization of the mathematical library for a generalized eigenvalue problem for real band matrices on IBM SP and Hitachi SR2201. The origin of the library is LASO (Lanczos Algorithm with Selective Orthogonalization), which was developed on the basis of Block Lanczos method for standard eigenvalue problem for real band matrices at Texas University. We adopted D.O.F. (Degree Of Freedom) decomposition method for a parallelization of this library, and evaluated its parallel performance. (author)

  18. Ferritin associates with marginal band microtubules

    International Nuclear Information System (INIS)

    Infante, Anthony A.; Infante, Dzintra; Chan, M.-C.; How, P.-C.; Kutschera, Waltraud; Linhartova, Irena; Muellner, Ernst W.; Wiche, Gerhard; Propst, Friedrich

    2007-01-01

    We characterized chicken erythrocyte and human platelet ferritin by biochemical studies and immunofluorescence. Erythrocyte ferritin was found to be a homopolymer of H-ferritin subunits, resistant to proteinase K digestion, heat stable, and contained iron. In mature chicken erythrocytes and human platelets, ferritin was localized at the marginal band, a ring-shaped peripheral microtubule bundle, and displayed properties of bona fide microtubule-associated proteins such as tau. Red blood cell ferritin association with the marginal band was confirmed by temperature-induced disassembly-reassembly of microtubules. During erythrocyte differentiation, ferritin co-localized with coalescing microtubules during marginal band formation. In addition, ferritin was found in the nuclei of mature erythrocytes, but was not detectable in those of bone marrow erythrocyte precursors. These results suggest that ferritin has a function in marginal band formation and possibly in protection of the marginal band from damaging effects of reactive oxygen species by sequestering iron in the mature erythrocyte. Moreover, our data suggest that ferritin and syncolin, a previously identified erythrocyte microtubule-associated protein, are identical. Nuclear ferritin might contribute to transcriptional silencing or, alternatively, constitute a ferritin reservoir

  19. Excited negative parity bands in 160Yb

    Science.gov (United States)

    Saha, A.; Bhattacharjee, T.; Curien, D.; Dedes, I.; Mazurek, K.; Banerjee, S. R.; Rajbanshi, S.; Bisoi, A.; de Angelis, G.; Bhattacharya, Soumik; Bhattacharyya, S.; Biswas, S.; Chakraborty, A.; Das Gupta, S.; Dey, B.; Goswami, A.; Mondal, D.; Pandit, D.; Palit, R.; Roy, T.; Singh, R. P.; Saha Sarkar, M.; Saha, S.; Sethi, J.

    2018-03-01

    Negative parity rotational bands in {} 70160Yb{}90 nucleus have been studied. They were populated in the 148Sm(16O, 4n)160Yb reaction at 90 MeV. The gamma-coincidence data have been collected using Indian National Gamma Array composed of twenty Compton suppressed clover germanium (Ge) detectors. Double gating on triple gamma coincidence data were selectively used to develop the decay scheme for these negative parity bands by identifying and taking care of the multiplet transitions. The even- and odd-spin negative parity bands in 160Yb have been studied by comparing the reduced transition probability ratios with the similar bands in neighbouring even-even rare earth nuclei. It is concluded that the concerned odd-spin and even-spin bands are not signature partners and that their structures are compatible with those of the ‘pear-shape’ and ‘pyramid-shape’ oscillations, respectively, the octupole shapes superposed with the quadrupole shape of the ground-state.

  20. Experimental study of energy harvesting in UHF band

    International Nuclear Information System (INIS)

    Bernacki, Ł; Gozdur, R; Salamon, N

    2016-01-01

    A huge progress of down-sizing technology together with trend of decreasing power consumption and, on the other hand, increasing efficiency of electronics give the opportunity to design and to implement the energy harvesters as main power sources. This paper refers to the energy that can be harvested from electromagnetic field in the unlicensed frequency bands. The paper contains description of the most popular techniques and transducers that can be applied in energy harvesting domain. The overview of current research and commercial solutions was performed for bands in ultra-high frequency range, which are unlicensed and where transmission is not limited by administrative arrangements. During the experiments with Powercast’s receiver, the same bands as sources of electromagnetic field were taken into account. This power source is used for conducting radio-communication process and excess energy could be used for powering the extra electronic circuits. The paper presents elaborated prototype of energy harvesting system and the measurements of power harvested in ultra-high frequency range. The evaluation of RF energy harvesters for powering ultra-low power (ULP) electronic devices was performed based on survey and results of the experiments. (paper)

  1. A compact dual band MIMO PIFA for 5G applications

    Science.gov (United States)

    Rachakonda, A.; Bang, P.; Mudiganti, J.

    2017-11-01

    5G applications support operations in 28, 37, 60 and 73GHz bands and is expected to support 1GHz bandwidth. In the present paper, planar inverted F antenna for 28GHz operation has been proposed for 5G applications for which a return loss of -17.46dB and a gain of 9.30dB have been observed. In addition, the design has been extended for dual band operation at 28 and 37GHz by implementing an L slot in the patch. An excellent return loss of -32.54dB and -18.57dB with a gain of 8.62dB has been observed. Moreover, a feasible bandwidth of 1.02GHz has been obtained in former design, while an enhanced bandwidth of 1.3GHz has been obtained at both bands in case of latter design. However, for better gain & data rate considerations, the previous design has been extended as a MIMO configuration with 2 antenna elements (2x1) and corresponding performance parameters have been evaluated.

  2. Band structural properties of MoS2 (molybdenite)

    International Nuclear Information System (INIS)

    Gupta, V.P.

    1980-01-01

    Semiconductivity and superconductivity in MoS 2 (molybdenite) can be understood in terms of the band structure of MoS 2 . The band structural properties of MoS 2 are presented here. The energy dependence of nsub(eff) and epsilon(infinity)sub(eff) is investigated. Using calculated values of nsub(eff) and epsilon(infinity)sub(eff), the Penn gap has been determined. The value thus obtained is shown to be in good agreement with the reflectivity data and also with the value obtained from the band structure. The Ravindra and Srivastava formula has been shown to give values for the isobaric temperature gradient of Esub(G)[(deltaEsub(G)/deltaT)sub(P)], which are in agreement with the experimental data, and the contribution to (deltaEsub(G)/deltaT)sub(P) due to the electron lattice interaction has been evaluated. In addition, the electronic polarizability has been calculated using a modified Lorentz-Lorenz relation. (author)

  3. Band gaps for the relativistic Mathieu potential

    International Nuclear Information System (INIS)

    Clerk, G.J.; McKellar, B.H.J.

    1992-01-01

    A study of the band structure of a massless particle in a cosine potential is made via the Dirac equation. It is shown that every alternate band gap disappears as a consequence of a periodicity of the potential combined with a peculiar symmetry of the Dirac equation. This basic potential is then used to study a simple one-dimensional model of the nucleus from which it is ascertained that modelling the mean field of the quarks in the nucleus via a pure scalar potential is unsatisfactory. A simple extension involving a combined scalar and vector potential is then proposed as a possible solution to this problem. The effect of the addition of this vector component to the band structure is also investigated. 32 refs

  4. What band rocks the MTB? (Invited)

    Science.gov (United States)

    Kind, J.; García-Rubio, I.; Gehring, A. U.

    2013-12-01

    Magnetotactic bacteria (MTB) are a polyphyletic group of bacteria that have been found in marine and lacustrine environments and soils [e.g. 1]. The hallmark of MTB is their intracellular formation of magnetosomes, single-domain ferrimagnetic particles that are aligned in chains. The chain configuration generates a strong magnetic dipole, which is used as magnetic compass to move the MTB into their favorable habit. The term band corresponds to a frequency window of microwaves in the gigahertz (GHz) range. Ferromagnetic resonance (FMR) spectroscopy uses the microwave absorption in a magnetic field to analyze the anisotropy properties and the domain state of magnetic materials. Specific microwave frequency causes absorption in a characteristic magnetic field range. For the investigation of MTB we use S-band (4.02 GHz), X-band (9.47 GHz), and Q-band (34.16 GHz). Experiments on cultured MTB and on sediment samples of Holocene age showed that absorption in X- and Q-band occurs when the sample is in a saturated or nearly saturated state [2, 3]. By contrast, absorption in the S-band appears in lower magnetic fields, where the sample is far from saturation. All FMR spectra show two distinct low-field features that can be assigned to magnetite particles in chains, aligned parallel and perpendicular to the external magnetic field. The detailed separation of the parallel and perpendicular components in the bulk samples is hampered, because of the random orientation of the chains in the sample. The comparison of S-, X-, and Q-band shows that the lower the frequency the better the separation of the components. In the S-band FMR spectroscopy, the separation of chains parallel to the external magnetic field is supported by the internal field of the sample. This field is caused by the remanence that contributes to the external magnetic field to fulfill the resonance condition [3,4]. Considering the different FMR responses, it can be postulated that a lower microwave frequency

  5. Some general constraints on identical band symmetries

    International Nuclear Information System (INIS)

    Guidry, M.W.; Strayer, M.R.; Wu, C.; Feng, D.H.

    1993-01-01

    We argue on general grounds that nearly identical bands observed for superdeformation and less frequently for normal deformation must be explicable in terms of a symmetry having a microscopic basis. We assume that the unknown symmetry is associated with a Lie algebra generated by terms bilinear in fermion creation and annihilation operators. Observed features of these bands and the general properties of Lie groups are then used to place constraints on acceptable algebras. Additional constraints are placed by assuming that the collective spectrum is associated with a dynamical symmetry, and examining the subgroup structure required by phenomenology. We observe that requisite symmetry cannot be unitary, and that the simplest known group structures consistent with these minimal criteria are associated with the Ginocchio algebras employed in the fermion dynamical symmetry model. However, our arguments are general in nature, and we propose that they imply model-independent constraints on any candidate explanation for identical bands

  6. Simplicial band depth for multivariate functional data

    KAUST Repository

    López-Pintado, Sara

    2014-03-05

    We propose notions of simplicial band depth for multivariate functional data that extend the univariate functional band depth. The proposed simplicial band depths provide simple and natural criteria to measure the centrality of a trajectory within a sample of curves. Based on these depths, a sample of multivariate curves can be ordered from the center outward and order statistics can be defined. Properties of the proposed depths, such as invariance and consistency, can be established. A simulation study shows the robustness of this new definition of depth and the advantages of using a multivariate depth versus the marginal depths for detecting outliers. Real data examples from growth curves and signature data are used to illustrate the performance and usefulness of the proposed depths. © 2014 Springer-Verlag Berlin Heidelberg.

  7. Exact folded-band chaotic oscillator.

    Science.gov (United States)

    Corron, Ned J; Blakely, Jonathan N

    2012-06-01

    An exactly solvable chaotic oscillator with folded-band dynamics is shown. The oscillator is a hybrid dynamical system containing a linear ordinary differential equation and a nonlinear switching condition. Bounded oscillations are provably chaotic, and successive waveform maxima yield a one-dimensional piecewise-linear return map with segments of both positive and negative slopes. Continuous-time dynamics exhibit a folded-band topology similar to Rössler's oscillator. An exact solution is written as a linear convolution of a fixed basis pulse and a discrete binary sequence, from which an equivalent symbolic dynamics is obtained. The folded-band topology is shown to be dependent on the symbol grammar.

  8. Kπ=0+ band moment of inertia anomaly

    International Nuclear Information System (INIS)

    Zeng, J.Y.; Wu, C.S.; Cheng, L.; Lin, C.Z.; China Center of Advanced Science and Technology

    1990-01-01

    The moments of inertia of K π =0 + bands in the well-deformed nuclei are calculated by a particle-number-conserving treatment for the cranked shell model. The very accurate solutions to the low-lying K π =0 + bands are obtained by making use of an effective K truncation. Calculations show that the main contribution to the moments of inertia comes from the nucleons in the intruding high-j orbits. Considering the fact that no free parameter is involved in the calculation and no extra inert core contribution is added, the agreement between the calculated and the observed moments of inertia of 0 + bands in 168 Er is very satisfactory

  9. Band Edge Dynamics and Multiexciton Generation in Narrow Band Gap HgTe Nanocrystals.

    Science.gov (United States)

    Livache, Clément; Goubet, Nicolas; Martinez, Bertille; Jagtap, Amardeep; Qu, Junling; Ithurria, Sandrine; Silly, Mathieu G; Dubertret, Benoit; Lhuillier, Emmanuel

    2018-04-11

    Mercury chalcogenide nanocrystals and especially HgTe appear as an interesting platform for the design of low cost mid-infrared (mid-IR) detectors. Nevertheless, their electronic structure and transport properties remain poorly understood, and some critical aspects such as the carrier relaxation dynamics at the band edge have been pushed under the rug. Some of the previous reports on dynamics are setup-limited, and all of them have been obtained using photon energy far above the band edge. These observations raise two main questions: (i) what are the carrier dynamics at the band edge and (ii) should we expect some additional effect (multiexciton generation (MEG)) as such narrow band gap materials are excited far above the band edge? To answer these questions, we developed a high-bandwidth setup that allows us to understand and compare the carrier dynamics resonantly pumped at the band edge in the mid-IR and far above the band edge. We demonstrate that fast (>50 MHz) photoresponse can be obtained even in the mid-IR and that MEG is occurring in HgTe nanocrystal arrays with a threshold around 3 times the band edge energy. Furthermore, the photoresponse can be effectively tuned in magnitude and sign using a phototransistor configuration.

  10. Side-band-separating heterodyne mixer for band 9 of ALMA.

    NARCIS (Netherlands)

    Mena, F. P.; Baryshev, A. M.; Kooi, J.; Lodewijk, C. F. J.; Gerlofsma, G.; Hesper, R.; Wild, W.; Shen, XC; Lu, W; Zhang, J; Dou, WB

    2006-01-01

    Here we present the realization of a side-band-separating (2SB) heterodyne mixer for the frequency range from 602 to 720 GHz (corresponding to ALMA band 9). The mixer, in brief, consists of a quadrature hybrid, two LO injectors, two SIS junctions, and three dumping loads. All the parts were modeled

  11. Elastic band prediction equations for combined free-weight and elastic band bench presses and squats.

    Science.gov (United States)

    Shoepe, Todd C; Ramirez, David A; Almstedt, Hawley C

    2010-01-01

    Elastic bands added to traditional free-weight techniques have become a part of suggested training routines in recent years. Because of the variable loading patterns of elastic bands (i.e., greater stretch produces greater resistance), it is necessary to quantify the exact loading patterns of bands to identify the volume and intensity of training. The purpose of this study was to determine the length vs. tension properties of multiple sizes of a set of commonly used elastic bands to quantify the resistance that would be applied to free-weight plus elastic bench presses (BP) and squats (SQ). Five elastic bands of varying thickness were affixed to an overhead support beam. Dumbbells of varying weights were progressively added to the free end while the linear deformation was recorded with each subsequent weight increment. The resistance was plotted as a factor of linear deformation, and best-fit nonlinear logarithmic regression equations were then matched to the data. For both the BP and SQ loading conditions and all band thicknesses tested, R values were greater than 0.9623. These data suggest that differences in load exist as a result of the thickness of the elastic band, attachment technique, and type of exercise being performed. Facilities should adopt their own form of loading quantification to match their unique set of circumstances when acquiring, researching, and implementing elastic band and free-weight exercises into the training programs.

  12. Band-gap and band-edge engineering of multicomponent garnet scintillators from first principles

    Czech Academy of Sciences Publication Activity Database

    Yadav, S.K.; Uberuaga, B.P.; Nikl, Martin; Jiang, C.; Stanek, C.R.

    2015-01-01

    Roč. 4, č. 5 (2015), "054012-1"-"054012-9" ISSN 2331-7019 R&D Projects: GA ČR GAP204/12/0805 Institutional support: RVO:68378271 Keywords : scintillator * electronic band gap structure * garnets * band gap engineering Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 4.061, year: 2015

  13. Interpolation of band-limited discrete-time signals by minimising out-of-band energy

    NARCIS (Netherlands)

    Janssen, A.J.E.M.; Vries, L.B.

    1984-01-01

    An interpolation method for restoring burst errors in discrete—time, band—limited signals is presented. The restoration is such that the restored signal has minimal out—of—band energy. The filter coefficients depend Only on the burst length and on the size of the band to which the signal is assumed

  14. Band to Band Tunneling (BBT) Induced Leakage Current Enhancement in Irradiated Fully Depleted SOI Devices

    Science.gov (United States)

    Adell, Phillipe C.; Barnaby, H. J.; Schrimpf, R. D.; Vermeire, B.

    2007-01-01

    We propose a model, validated with simulations, describing how band-to-band tunneling (BBT) affects the leakage current degradation in some irradiated fully-depleted SOI devices. The dependence of drain current on gate voltage, including the apparent transition to a high current regime is explained.

  15. Modelling band-to-band tunneling current in InP-based heterostructure photonic devices

    NARCIS (Netherlands)

    van Engelen, J.P.; Shen, L.; van der Tol, J.J.G.M.; Smit, M.K.; Kockaert, P.; Emplit, P.; Gorza, S.-P.; Massar, S.

    2015-01-01

    Some semiconductor photonic devices show large discontinuities in the band structure. Short tunnel paths caused by this band structure may lead to an excessive tunneling current, especially in highly doped layers. Modelling of this tunnelling current is therefore important when designing photonic

  16. Increased theta band EEG power in sickle cell disease patients

    Directory of Open Access Journals (Sweden)

    Case M

    2017-12-01

    Full Text Available Michelle Case,1 Sina Shirinpour,1 Huishi Zhang,1 Yvonne H Datta,2 Stephen C Nelson,3 Karim T Sadak,4 Kalpna Gupta,2 Bin He1,5 1Department of Biomedical Engineering, 2Department of Medicine, University of Minnesota, 3Pediatric Hematology-Oncology, Children’s Hospitals and Clinics of Minnesota, 4Pediatric Hematology-Oncology, University of Minnesota Masonic Children’s Hospital, 5Institute for Engineering in Medicine, University of Minnesota, Minneapolis, MN, USA Objective: Pain is a major issue in the care of patients with sickle cell disease (SCD. The mechanisms behind pain and the best way to treat it are not well understood. We studied how electroencephalography (EEG is altered in SCD patients. Methods: We recruited 20 SCD patients and compared their resting state EEG to that of 14 healthy controls. EEG power was found across frequency bands using Welch’s method. Electrophysiological source imaging was assessed for each frequency band using the eLORETA algorithm. Results: SCD patients had increased theta power and decreased beta2 power compared to controls. Source localization revealed that areas of greater theta band activity were in areas related to pain processing. Imaging parameters were significantly correlated to emergency department visits, which indicate disease severity and chronic pain intensity. Conclusion: The present results support the pain mechanism referred to as thalamocortical dysrhythmia. This mechanism causes increased theta power in patients. Significance: Our findings show that EEG can be used to quantitatively evaluate differences between controls and SCD patients. Our results show the potential of EEG to differentiate between different levels of pain in an unbiased setting, where specific frequency bands could be used as biomarkers for chronic pain. Keywords: sickle cell disease, electroencephalography, chronic pain, electrophysiological source imaging, thalamocortical dysrhythmia

  17. Structure of dipole bands in 106In

    International Nuclear Information System (INIS)

    Deo, A. Y.; Palit, R.; Naik, Z.; Joshi, P. K.; Mazumdar, I.; Sihotra, S.; Mehta, D.; Kumar, S.; Chakrabarti, R.; Kshetri, R.; Jain, H. C.

    2009-01-01

    High spin states in neutron-deficient 106 In were investigated using 78 Se( 32 S,p3n) reaction at 125 MeV. The level scheme is extended up to 7 MeV of excitation energy for the negative parity states constituting four dipole bands, and the positive parity states which mainly exhibit single-particle excitations are extended up to 5 MeV. Projected deformed Hartree-Fock calculations were carried out to understand the configurations of different bands in this nucleus.

  18. Maximizing band gaps in plate structures

    DEFF Research Database (Denmark)

    Halkjær, Søren; Sigmund, Ole; Jensen, Jakob Søndergaard

    2006-01-01

    periodic plate using Bloch theory, which conveniently reduces the maximization problem to that of a single base cell. Secondly, we construct a finite periodic plate using a number of the optimized base cells in a postprocessed version. The dynamic properties of the finite plate are investigated......Band gaps, i.e., frequency ranges in which waves cannot propagate, can be found in elastic structures for which there is a certain periodic modulation of the material properties or structure. In this paper, we maximize the band gap size for bending waves in a Mindlin plate. We analyze an infinite...... theoretically and experimentally and the issue of finite size effects is addressed....

  19. Itinerant ferromagnetism in the narrow band limit

    CERN Document Server

    Liu, S H

    2000-01-01

    It is shown that in the narrow band, strong interaction limit the paramagnetic state of an itinerant ferromagnet is described by the disordered local moment state. As a result, the Curie temperature is orders of magnitude lower than what is expected from the large exchange splitting of the spin bands. An approximate analysis has also been carried out for the partially ordered state, and the result explains the temperature evolvement of the magnetic contributions to the resistivity and low-energy optical conductivity of CrO sub 2.

  20. Proximal iliotibial band syndrome: case report

    Directory of Open Access Journals (Sweden)

    Guilherme Guadagnini Falotico

    2013-08-01

    Full Text Available OBJECTIVE: The overuse injuries in the hip joint occur commonly in sports practitioners and currently due to technical advances in diagnostic imaging, especially magnetic resonance imaging (MRI, are often misdiagnosed. Recently, a group of people were reported, all female, with pain and swelling in the pelvic region.T2-weighted MRI showed increased signal in the enthesis of the iliotibial band (ITB along the lower border of the iliac tubercle. We report a case of a 34 year old woman, non-professional runner, with pain at the iliac crest with no history of trauma and whose MRI was compatible with the proximal iliotibial band syndrome.

  1. Electron currents associated with an auroral band

    International Nuclear Information System (INIS)

    Spiger, R.J.; Anderson, H.R.

    1975-01-01

    Measurements of electron pitch angle distributions and energy spectra over a broad auroral band were used to calculate net electric current carried by auroral electrons in the vicinity of the band. The particle energy spectrometers were carried by a Nike-Tomahawk rocket launched from Poker Flat, Alaska, at 0722 UT on February 25, 1972. Data are presented which indicate the existence of upward field-aligned currents of electrons in the energy range 0.5-20 keV. The spatial relationship of these currents to visual structure of the auroral arc and the characteristics of the electrons carrying the currents are discussed

  2. Electron currents associated with an auroral band

    Science.gov (United States)

    Spiger, R. J.; Anderson, H. R.

    1975-01-01

    Measurements of electron pitch angle distributions and energy spectra over a broad auroral band were used to calculate net electric current carried by auroral electrons in the vicinity of the band. The particle energy spectrometers were carried by a Nike-Tomahawk rocket launched from Poker Flat, Alaska, at 0722 UT on February 25, 1972. Data are presented which indicate the existence of upward field-aligned currents of electrons in the energy range 0.5-20 keV. The spatial relationship of these currents to visual structure of the auroral arc and the characteristics of the electrons carrying the currents are discussed.

  3. Ka-band waveguide rotary joint

    KAUST Repository

    Yevdokymov, Anatoliy

    2013-04-11

    The authors present a design of a waveguide rotary joint operating in Ka-band with central frequency of 33 GHz, which also acts as an antenna mount. The main unit consists of two flanges with a clearance between them; one of the flanges has three circular choke grooves. Utilisation of three choke grooves allows larger operating clearance. Two prototypes of the rotary joint have been manufactured and experimentally studied. The observed loss is from 0.4 to 0.8 dB in 1.5 GHz band.

  4. Band theory of metals the elements

    CERN Document Server

    Altmann, Simon L

    1970-01-01

    Band Theory of Metals: The Elements focuses on the band theory of solids. The book first discusses revision of quantum mechanics. Topics include Heisenberg's uncertainty principle, normalization, stationary states, wave and group velocities, mean values, and variational method. The text takes a look at the free-electron theory of metals, including heat capacities, density of states, Fermi energy, core and metal electrons, and eigenfunctions in three dimensions. The book also reviews the effects of crystal fields in one dimension. The eigenfunctions of the translations; symmetry operations of t

  5. Banding of connection standards for distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-04

    This report presents the views of distributed network operators (DNOs), developers, equipment manufacturers and consultants on the current banding of distributed generation in terms of connection standards and recommendations. The Documents ER G59/1, ER G75/1, ER G83/1 and ETR 113/1 covering recommendations for the connection of embedded generating plant to distribution systems and guidance notes for the protection of embedded generating plant are examined. The way in which the recommendations are applied in practice is investigated. Multiple distribution generator installations, fault ride through, and banding are considered as well as both protection required and maximum generator sizes at respective voltage levels.

  6. Quantum numbers and band topology of nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Damnjanovic, M [Faculty of Physics, University of Belgrade, POB 368, 11001 Belgrade (Yugoslavia); Milosevic, I [Faculty of Physics, University of Belgrade, POB 368, 11001 Belgrade (Yugoslavia); Vukovic, T [Faculty of Physics, University of Belgrade, POB 368, 11001 Belgrade (Yugoslavia); Maultzsch, J [Institut fuer Festkoerper Physik, Technische Universitaet Berlin, Hardenbergstr. 36, 10623 Berlin (Germany)

    2003-05-30

    Nanotubes as well as polymers and quasi-1D subsystems of 3D crystals have line group symmetry. This allows two types of quantum numbers: roto-translational and helical. The roto-translational quantum numbers are linear and total angular (not conserved) momenta, while the helical quantum numbers are helical and complementary angular momenta. Their mutual relations determine some topological properties of energy bands, such as systematic band sticking or van Hove singularities related to parities. The importance of these conclusions is illustrated by the optical absorption in carbon nanotubes: parity may prevent absorption peaks at van Hove singularities.

  7. Quantum numbers and band topology of nanotubes

    International Nuclear Information System (INIS)

    Damnjanovic, M; Milosevic, I; Vukovic, T; Maultzsch, J

    2003-01-01

    Nanotubes as well as polymers and quasi-1D subsystems of 3D crystals have line group symmetry. This allows two types of quantum numbers: roto-translational and helical. The roto-translational quantum numbers are linear and total angular (not conserved) momenta, while the helical quantum numbers are helical and complementary angular momenta. Their mutual relations determine some topological properties of energy bands, such as systematic band sticking or van Hove singularities related to parities. The importance of these conclusions is illustrated by the optical absorption in carbon nanotubes: parity may prevent absorption peaks at van Hove singularities

  8. Quantum numbers and band topology of nanotubes

    CERN Document Server

    Damnjanovic, M; Vukovic, T; Maultzsch, J

    2003-01-01

    Nanotubes as well as polymers and quasi-1D subsystems of 3D crystals have line group symmetry. This allows two types of quantum numbers: roto-translational and helical. The roto-translational quantum numbers are linear and total angular (not conserved) momenta, while the helical quantum numbers are helical and complementary angular momenta. Their mutual relations determine some topological properties of energy bands, such as systematic band sticking or van Hove singularities related to parities. The importance of these conclusions is illustrated by the optical absorption in carbon nanotubes: parity may prevent absorption peaks at van Hove singularities.

  9. Neutron transmission bands in one dimensional lattices

    International Nuclear Information System (INIS)

    Monsivais, G.; Moshinsky, M.

    1999-01-01

    The original Kronig-Penney lattice, which had delta function interactions at the end of each of the equal segments, seems a good model for the motion of neutrons in a linear lattice if the strength b of the δ functions depends of the energy of the neutrons, i.e., b(E). We derive the equation for the transmission bands and consider the relations of b(E) with the R(E) function discussed in a previous paper. We note the great difference in the behavior of the bands when b(E) is constant and when it is related with a single resonance of the R function. (Author)

  10. Band gap and band offset of (GaIn)(PSb) lattice matched to InP

    Science.gov (United States)

    Köhler, F.; Böhm, G.; Meyer, R.; Amann, M.-C.

    2005-07-01

    Metastable (GaxIn1-x)(PySb1-y) layers were grown on (001) InP substrates by gas source molecular beam epitaxy. Low-temperature photoluminescence spectroscopy was applied to these heterostructures and revealed spatially indirect band-to-band recombination of electrons localized in the InP with holes in the (GaxIn1-x)(PySb1-y). In addition, samples with layer thicknesses larger than 100nm showed direct PL across the band gap of (GaxIn1-x)(PySb1-y). Band-gap energies and band offset energies of (GaxIn1-x)(PySb1-y) relative to InP were derived from these PL data. A strong bowing parameter was observed.

  11. Coastal flood inundation monitoring with Satellite C-band and L-band Synthetic Aperture Radar data

    Science.gov (United States)

    Ramsey, Elijah W.; Rangoonwala, Amina; Bannister, Terri

    2013-01-01

    Satellite Synthetic Aperture Radar (SAR) was evaluated as a method to operationally monitor the occurrence and distribution of storm- and tidal-related flooding of spatially extensive coastal marshes within the north-central Gulf of Mexico. Maps representing the occurrence of marsh surface inundation were created from available Advanced Land Observation Satellite (ALOS) Phased Array type L-Band SAR (PALSAR) (L-band) (21 scenes with HH polarizations in Wide Beam [100 m]) data and Environmental Satellite (ENVISAT) Advanced SAR (ASAR) (C-band) data (24 scenes with VV and HH polarizations in Wide Swath [150 m]) during 2006-2009 covering 500 km of the Louisiana coastal zone. Mapping was primarily based on a decrease in backscatter between reference and target scenes, and as an extension of previous studies, the flood inundation mapping performance was assessed by the degree of correspondence between inundation mapping and inland water levels. Both PALSAR- and ASAR-based mapping at times were based on suboptimal reference scenes; however, ASAR performance seemed more sensitive to reference-scene quality and other types of scene variability. Related to water depth, PALSAR and ASAR mapping accuracies tended to be lower when water depths were shallow and increased as water levels decreased below or increased above the ground surface, but this pattern was more pronounced with ASAR. Overall, PALSAR-based inundation accuracies averaged 84% (n = 160), while ASAR-based mapping accuracies averaged 62% (n = 245).

  12. ANALISIS TIPOGRAFI PADA LOGOTYPE BAND FORGOTTEN

    Directory of Open Access Journals (Sweden)

    Atang Riyan Isnandar

    2016-12-01

    Full Text Available Abstrak Forgotten merupakan band asal kota Bandung yang beraliran death metal. Band ini telah memiliki beberapa album yang cukup sukses. Salah satu faktor yang turut berperan penting dalam album-album Forgotten adalah desain sampul album. Sampul album merupakan identitas dan pesan dari musik yang dibawakan oleh Forgotten. Dalam sampul album, terdapat salah satu elemen visual yaitu Tipografi. Salah satu peran tipografi dalam sampul album Forgotten adalah sebagai logotype dari band. Yang menarik, dari lima album yang telah dirilis Forgotten yaitu “Future Syndrome” (1997, “Obsesi Mati” (2000, “Tuhan Telah Mati” (2001, “Tiga Angka Enam” (2003 dan “Laras Perlaya” (2011 adalah tampilan logotype band yang selalu berbeda. Perubahan logotype Forgotten disebabkan oleh beberapa faktor seperti adanya perubahan selera, transformasi musik dan pergantian personil yang dialami oleh band Forgotten. Perubahan ini berakibat pada munculnya kesan visual yang berbeda-beda dari masing-masing logotype di setiap sampul albumnya. Apalagi logotype band dengan genre death metal memiliki kecendrungan yang unik, dekoratif, bahkan sulit untuk dibaca. Oleh karena itu untuk mengetahui kesan visual yang dimunculkan oleh setiap logotype akan dilakukan penelitian dengan pendekatan tipografi. Tujuan dari penelitian ini adalah selain untuk mengetahui perubahan logotype dari kelima sampul album yang telah dirilis oleh Forgotten juga ingin mengetahui kesan visual terhadap tipografi terkait dengan prinsip kejelasan (legibility, keterbacaan (readability dan kemampuannya untuk dilihat pada jarak tertentu (visibility. Kata Kunci: Sampul Album, Tipografi, Logotype, Forgotten Abstract Forgotten is a band from Bandung, the death metal genre. The band has had some fairly successful album. One of important factor in albums Forgotten is the album cover design. The album cover are the identity and the message of the music performed by the Forgotten. In the cover of the album

  13. Effects of elastic band exercises on physical ability and muscular topography of elderlyfemales.

    Science.gov (United States)

    Lee, Jung Won; Kim, Suk Bum; Kim, Seong Wook

    2018-02-01

    [Purpose] This study examined the effects of band exercise types on the physical ability and muscular topography for elderly females. [Subjects and Methods] Twenty-six females older than 65 years were divided into the dynamic band exercise (DBE; n=13) group and the Static band exercise (SBE; n=13) group. Each participant performed 12 weeks of elastic band exercises. Physical abilities were measured by leg extension power, sitting trunk flexion, closed eyes foot balance, and time to get up. Changes in muscle topography were evaluated with Moire measurement equipment for the chest, abdomen, and lumbar region. All results were compared before and after 12 weeks of exercise. [Results] Changes in physical ability were significantly increased in both groups. The scores for the muscular topography of the chest, abdomen, lumbar region, and all body parts was significantly improved in both groups for closed eyes foot balance. There were more improvements in the DBE group. [Conclusion] Two types of static and dynamic elastic band exercises effectively changed the physical fitness and muscle topography of elderly females. Therefore, to increase the effects of exercise, dynamic band exercises are considered useful. Because band exercises are simple, they can be used to maintain the health of elderly people.

  14. Quasiparticle band structure of rocksalt-CdO determined using maximally localized Wannier functions.

    Science.gov (United States)

    Dixit, H; Lamoen, D; Partoens, B

    2013-01-23

    CdO in the rocksalt structure is an indirect band gap semiconductor. Thus, in order to determine its band gap one needs to calculate the complete band structure. However, in practice, the exact evaluation of the quasiparticle band structure for the large number of k-points which constitute the different symmetry lines in the Brillouin zone can be an extremely demanding task compared to the standard density functional theory (DFT) calculation. In this paper we report the full quasiparticle band structure of CdO using a plane-wave pseudopotential approach. In order to reduce the computational effort and time, we make use of maximally localized Wannier functions (MLWFs). The MLWFs offer a highly accurate method for interpolation of the DFT or GW band structure from a coarse k-point mesh in the irreducible Brillouin zone, resulting in a much reduced computational effort. The present paper discusses the technical details of the scheme along with the results obtained for the quasiparticle band gap and the electron effective mass.

  15. Hyperspectral band selection based on consistency-measure of neighborhood rough set theory

    International Nuclear Information System (INIS)

    Liu, Yao; Xie, Hong; Wang, Liguo; Tan, Kezhu; Chen, Yuehua; Xu, Zhen

    2016-01-01

    Band selection is a well-known approach for reducing dimensionality in hyperspectral imaging. In this paper, a band selection method based on consistency-measure of neighborhood rough set theory (CMNRS) was proposed to select informative bands from hyperspectral images. A decision-making information system was established by the reflection spectrum of soybeans’ hyperspectral data between 400 nm and 1000 nm wavelengths. The neighborhood consistency-measure, which reflects not only the size of the decision positive region, but also the sample distribution in the boundary region, was used as the evaluation function of band significance. The optimal band subset was selected by a forward greedy search algorithm. A post-pruning strategy was employed to overcome the over-fitting problem and find the minimum subset. To assess the effectiveness of the proposed band selection technique, two classification models (extreme learning machine (ELM) and random forests (RF)) were built. The experimental results showed that the proposed algorithm can effectively select key bands and obtain satisfactory classification accuracy. (paper)

  16. CPM Signals for Satellite Navigation in the S and C Bands.

    Science.gov (United States)

    Xue, Rui; Sun, Yanbo; Zhao, Danfeng

    2015-06-05

    Frequency allocations in the L band suitable for global navigation satellite system (GNSS) services are getting crowded and system providers face an ever tougher job when they try to bring in new signals and services while maintaining radio frequency compatibility. With the successive opening of the S and C bands to GNSS service, the multi-band combined navigation is predicted to become a key technology for future high-precision positioning navigation systems, and a single modulation scheme satisfying the requirements in each band is a promising solution for reducing user terminal complexity. A universal modulation scheme based on the continuous phase modulation (CPM) family suitable for the above bands' demands is proposed. Moreover, this paper has put forward two specific CPM signals for the S and C bands, respectively. Then the proposed modulation schemes, together with existing candidates, are comprehensively evaluated. Simulation results show that the proposed CPM signals can not only satisfy the constraint condition of compatibility in different bands well and reduce user terminal complexity, but also provide superior performance in terms of tracking accuracy, multi-path mitigation and anti-jamming compared to other candidate modulation schemes.

  17. Banding the world together; the global growth of control banding and qualitative occupational risk management.

    Science.gov (United States)

    Zalk, David M; Heussen, Ga Henri

    2011-12-01

    Control Banding (CB) strategies to prevent work-related illness and injury for 2.5 billion workers without access to health and safety professionals has grown exponentially this last decade. CB originates from the pharmaceutical industry to control active pharmaceutical ingredients without a complete toxicological basis and therefore no occupational exposure limits. CB applications have broadened into chemicals in general - including new emerging risks like nanomaterials and recently into ergonomics and injury prevention. CB is an action-oriented qualitative risk assessment strategy offering solutions and control measures to users through "toolkits". Chemical CB toolkits are user-friendly approaches used to achieve workplace controls in the absence of firm toxicological and quantitative exposure information. The model (technical) validation of these toolkits is well described, however firm operational analyses (implementation aspects) are lacking. Consequentially, it is often not known if toolkit use leads to successful interventions at individual workplaces. This might lead to virtual safe workplaces without knowing if workers are truly protected. Upcoming international strategies from the World Health Organization Collaborating Centers request assistance in developing and evaluating action-oriented procedures for workplace risk assessment and control. It is expected that to fulfill this strategy's goals, CB approaches will continue its important growth in protecting workers.

  18. Banding the World Together; The Global Growth of Control Banding and Qualitative Occupational Risk Management

    Directory of Open Access Journals (Sweden)

    David M. Zalk

    2011-12-01

    Full Text Available Control Banding (CB strategies to prevent work-related illness and injury for 2.5 billion workers without access to health and safety professionals has grown exponentially this last decade. CB originates from the pharmaceutical industry to control active pharmaceutical ingredients without a complete toxicological basis and therefore no occupational exposure limits. CB applications have broadened into chemicals in general - including new emerging risks like nanomaterials and recently into ergonomics and injury prevention. CB is an action-oriented qualitative risk assessment strategy offering solutions and control measures to users through “toolkits”. Chemical CB toolkits are user-friendly approaches used to achieve workplace controls in the absence of firm toxicological and quantitative exposure information. The model (technical validation of these toolkits is well described, however firm operational analyses (implementation aspects are lacking. Consequentially, it is often not known if toolkit use leads to successful interventions at individual workplaces. This might lead to virtual safe workplaces without knowing if workers are truly protected. Upcoming international strategies from the World Health Organization Collaborating Centers request assistance in developing and evaluating action-oriented procedures for workplace risk assessment and control. It is expected that to fulfill this strategy’s goals, CB approaches will continue its important growth in protecting workers.

  19. 47 CFR 15.715 - TV bands database administrator.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false TV bands database administrator. 15.715 Section... Band Devices § 15.715 TV bands database administrator. The Commission will designate one or more entities to administer a TV bands database. Each database administrator shall: (a) Maintain a database that...

  20. New Kronig-Penney Equation Emphasizing the Band Edge Conditions

    Science.gov (United States)

    Szmulowicz, Frank

    2008-01-01

    The Kronig-Penney problem is a textbook example for discussing band dispersions and band gap formation in periodic layered media. For example, in photonic crystals, the behaviour of bands next to the band edges is important for further discussions of such effects as inhibited light emission, slow light and negative index of refraction. However,…

  1. 47 CFR 15.714 - TV bands database administration fees.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false TV bands database administration fees. 15.714... Television Band Devices § 15.714 TV bands database administration fees. (a) A TV bands database administrator may charge a fee for provision of lists of available channels to fixed and personal/portable TVBDs and...

  2. 47 CFR 15.713 - TV bands database.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false TV bands database. 15.713 Section 15.713... TV bands database. (a) Purpose. The TV bands database serves the following functions: (1) To... databases. (b) Information in the TV bands database. (1) Facilities already recorded in Commission databases...

  3. Bands and chromosome arrangement in interphase nuclei

    International Nuclear Information System (INIS)

    Bianchi, N.O.; Bianchi, M.A.; Matayoshi, T.

    1977-01-01

    Chromosomes from the vole mouse Akodon dolores and from laboratory mouse showed the presence of G-bands after 3 minutes digestion with trypsin and Giemsa stain. Simultaneously, 30- to 40% of the interphase nuclei exhibited a dark ring parallel to the nuclear contour and a radial array of the chromatin in the internal and external regions of the ring. The origin and meaning of this ring image was analyzed by combining progressive trypsinizations with other methods such as C-banding procedures, autoradiography with 3 HTdR, staining with quinacrine mustard and 33258 Hoechst fluorochromes. Moreover, the presence of the dark ring was also investigated in cells treated with actinomycin and in control cells not subjected to any treatment. The results obtained allowed to assume that in interphase nuclei the chromosomes have chromatin bridges which connect the dark G-bands and that these bridges are probably involved in maintaining an ordered architecture of the nucleus with fixed chromosome positions in regard to the nuclear envelope and in regard to other chromosomes. Trypsinization produces a disruption of the interphase chromatin arrangement and the subsequent appearance of a dark ring formed by the combination of constitutive heterochromatin and dark G-bands. (auth.)

  4. Deformed configurations, band structures and spectroscopic ...

    Indian Academy of Sciences (India)

    2014-03-20

    Mar 20, 2014 ... The deformed configurations and rotational band structures in =50 Ge and Se nuclei are studied by deformed Hartree–Fock with quadrupole constraint and angular momentum projection. Apart from the `almost' spherical HF solution, a well-deformed configuration occurs at low excitation. A deformed ...

  5. VIBRONIC PROGRESSIONS IN SEVERAL DIFFUSE INTERSTELLAR BANDS

    International Nuclear Information System (INIS)

    Duley, W. W.; Kuzmin, Stanislav

    2010-01-01

    A number of vibronic progressions based on low-energy vibrational modes of a large molecule have been found in the diffuse interstellar band (DIB) spectrum of HD 183143. Four active vibrational modes have been identified with energies at 5.18 cm -1 , 21.41 cm -1 , 31.55 cm -1 , and 34.02 cm -1 . The mode at 34.02 cm -1 was previously recognized by Herbig. Four bands are associated with this molecule, with origins at 6862.61 A, 6843.64 A, 6203.14 A, and 5545.11 A (14589.1 cm -1 , 14608.08 cm -1 , 16116.41 cm -1 , and 18028.9 cm -1 , respectively). The progressions are harmonic and combination bands are observed involving all modes. The appearance of harmonic, rather than anharmonic, terms in these vibronic progressions is consistent with torsional motion of pendant rings, suggesting that the carrier is a 'floppy' molecule. Some constraints on the type and size of the molecule producing these bands are discussed.

  6. Statistical study of auroral omega bands

    Directory of Open Access Journals (Sweden)

    N. Partamies

    2017-09-01

    Full Text Available The presence of very few statistical studies on auroral omega bands motivated us to test-use a semi-automatic method for identifying large-scale undulations of the diffuse aurora boundary and to investigate their occurrence. Five identical all-sky cameras with overlapping fields of view provided data for 438 auroral omega-like structures over Fennoscandian Lapland from 1996 to 2007. The results from this set of omega band events agree remarkably well with previous observations of omega band occurrence in magnetic local time (MLT, lifetime, location between the region 1 and 2 field-aligned currents, as well as current density estimates. The average peak emission height of omega forms corresponds to the estimated precipitation energies of a few keV, which experienced no significant change during the events. Analysis of both local and global magnetic indices demonstrates that omega bands are observed during substorm expansion and recovery phases that are more intense than average substorm expansion and recovery phases in the same region. The omega occurrence with respect to the substorm expansion and recovery phases is in a very good agreement with an earlier observed distribution of fast earthward flows in the plasma sheet during expansion and recovery phases. These findings support the theory that omegas are produced by fast earthward flows and auroral streamers, despite the rarity of good conjugate observations.

  7. Collective states in 230Th: band structure

    Directory of Open Access Journals (Sweden)

    A. I. Levon

    2009-12-01

    Full Text Available Experimental data for the excited states in the deformed nucleus 230Th studied in the (p, t reaction are analyzed. Sequences of the states are selected which can be treated as rotational bands and as multiplets of excitations. Experimental data are compared with the interacting boson model (IBM and the quasiparticle-phonon model (QPM calculations.

  8. Study on electromagnetic constants of rotational bands

    International Nuclear Information System (INIS)

    Abdurazakov, A.A.; Adib, Yu.Sh.; Karakhodzhaev, A.K.

    1991-01-01

    Values of electromagnetic constant S and rotation bands of odd nuclei with Z=64-70 within the mass number change interval A=153-173 are determined. Values of γ-transition mixing parameter with M1+E2 multipolarity are presented. ρ parameter dependence on mass number A is discussed

  9. High spin rotational bands in Zn

    Indian Academy of Sciences (India)

    We present here some preliminary results from our studies in the. ~ ¼ region in which we have observed an yrast band structure in Zn extending to spin (41/2 ). ... gaps implies that nuclei may exhibit different shapes at different excitation energies. .... uration, identifying previously unobserved states up to an excitation energy ...

  10. Energy bands and gaps near an impurity

    Czech Academy of Sciences Publication Activity Database

    Mihóková, Eva; Schulman, L. S.

    2016-01-01

    Roč. 380, č. 41 (2016), s. 3430-3433 ISSN 0375-9601 R&D Projects: GA ČR GA13-09876S Institutional support: RVO:68378271 Keywords : crystal structure * impurity * modeling * energy bands Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.772, year: 2016

  11. Ka-band waveguide rotary joint

    KAUST Repository

    Yevdokymov, Anatoliy; Sirenko, Kostyantyn; Kryzhanovskiy, Volodymyr; Pazynin, Vadim

    2013-01-01

    The authors present a design of a waveguide rotary joint operating in Ka-band with central frequency of 33 GHz, which also acts as an antenna mount. The main unit consists of two flanges with a clearance between them; one of the flanges has three

  12. A Shear Banding Model for Penetration Calculations

    Science.gov (United States)

    2000-04-01

    mechanism of strength reduction to zero within a shear band in three different steels, includ- ing AISI 4340 with RHC 44, which is reasonably similar to RHA...TECH LIB CHINA LAKE CA 93555-6001 CDR NAVAL SUR WAR CTR C S COFFEY PPARK FZERILLI CODE 4140 R K GARRET JR JMCKIRGAN TECH LIB 101 STRAUSS AVE

  13. Electron band theory 1952-1962

    International Nuclear Information System (INIS)

    Lomer, W.M.

    1980-01-01

    Work undertaken by the Theoretical Physics Division between 1952 and 1965 to obtain an understanding of electrons in metals, with uranium and the actinides and the structurally-important transition metals as the main targets is examined. A main result of that period was a conviction that the majority of the physical properties of all metals, except the 4f rare-earth series and the actinides beyond uranium, were dominated by band effects which could be described well enough for most purposes by simple one-electron calculations with simple self-consistent fields. The period from 1960 on showed increasingly clearly the necessity of incorporating relativistic spin-orbit coupling terms in the heavy metals, and some 'local exchange field' correction to the fields close to nuclei. The problems of the non-local interaction of spins - highly important for alloy theory and for antiferromagnetic instability -required the evolution of computers large enough to produce wave-functions at all wave-vectors for all bands so that the susceptibility at arbitrary wave-vector could be computed. This work has not proved to be very illuminating so far, and much interest again focusses today on heuristic arguments that give qualitative descriptions of band structures, such as canonical d-bands to account for crystal structure. (UK)

  14. Phononic band gap structures as optimal designs

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard; Sigmund, Ole

    2003-01-01

    In this paper we use topology optimization to design phononic band gap structures. We consider 2D structures subjected to periodic loading and obtain the distribution of two materials with high contrast in material properties that gives the minimal vibrational response of the structure. Both in...

  15. The end of the unique myocardial band

    DEFF Research Database (Denmark)

    MacIver, David H; Partridge, John B; Agger, Peter

    2018-01-01

    Two of the leading concepts of mural ventricular architecture are the unique myocardial band and the myocardial mesh model. We have described, in an accompanying article published in this journal, how the anatomical, histological and high-resolution computed tomographic studies strongly favour th...

  16. Piecewise planar Möbius bands

    DEFF Research Database (Denmark)

    Gravesen, Jens

    2005-01-01

    t is shown that a closed polygon with an odd number of vertices is the median of exactly one piecewise planar cylinder and one piecewise planar Möbius band, intersecting each other orthogonally. A closed polygon with an even number of vertices is in the generic case neither the median...

  17. PHARUS: A C-band Airborne SAR

    NARCIS (Netherlands)

    Hoogeboom, P.; Koomen, P.J.; Pouwels, H.; Snoeij, P.

    1990-01-01

    In The Netherlands a plan to design aircraft and build a polarimetric C-band SAR system of a novel design, called PHARUS (PHased Array Universal SAR) is carried out by three institutes. These institutes are the Physics and Electronics Laboratory TNO in The Hague (prime contractor and project

  18. Faraday Rotation and L Band Oceanographic Measurements

    DEFF Research Database (Denmark)

    Skou, Niels

    2003-01-01

    Spaceborne radiometric measurements of the L band brightness temperature over the oceans make it possible to estimate sea surface salinity. However, Faraday rotation in the ionosphere disturbs the signals and must be corrected. Two different ways of assessing the disturbance directly from...

  19. Summary and Analysis of the U.S. Government Bat Banding Program

    Science.gov (United States)

    Ellison, Laura E.

    2008-01-01

    This report summarizes the U.S. Government Bat Banding Program (BBP) from 1932 to 1972. More than 2 million bands were issued during the program, of which approximately 1.5 million bands were applied to 36 bat species by scientists in many locations in North America including the U.S., Canada, Mexico, and Central America. Throughout the BBP, banders noticed numerous and deleterious effects on bats, leading to a moratorium on bat banding by the U.S. Fish and Wildlife Service, and a resolution to cease banding by the American Society of Mammalogists in 1973. One of the main points of the memorandum written to justify the moratorium was to conduct a 'detailed evaluation of the files of the bat-banding program.' However, a critical and detailed evaluation of the BBP was never completed. In an effort to satisfy this need, I compiled a detailed history of the BBP by examining the files and conducting a literature review on bat banding activities during the program. I also provided a case study in managing data and applying current mark-recapture theory to estimate survival using the information from a series of bat bands issued to Clyde M. Senger during the BBP. The majority of bands applied by Senger were to Townsend's big-eared bat (Corynorhinus townsendii), a species of special concern for many states within its geographic range. I developed a database management system for the bat banding records and then analyzed and modeled survival of hibernating Townsend's big-eared bats at three main locations in Washington State using Cormack-Jolly-Seber (CJS) open models and the modeling capabilities of Program MARK. This analysis of a select dataset in the BBP files provided relatively precise estimates of survival for wintering Townsend's big-eared bats. However, this dataset is unique due to its well-maintained and complete state and because there were high recapture rates over the course of banding; it is doubtful that other unpublished datasets of the same quality exist

  20. The very low-frequency band of heart rate variability represents the slow recovery component after a mental stress task.

    Directory of Open Access Journals (Sweden)

    Harunobu Usui

    Full Text Available The very low-frequency (VLF band of heart rate variability (HRV has different characteristics compared with other HRV components. Here we investigated differences in HRV changes after a mental stress task. After the task, the high-frequency (HF band and ratio of high- to low-frequency bands (LF/HF immediately returned to baseline. We evaluated the characteristics of VLF band changes after a mental stress task. We hypothesized that the VLF band decreases during the Stroop color word task and there would be a delayed recovery for 2 h after the task (i.e., the VLF change would exhibit a "slow recovery". Nineteen healthy, young subjects were instructed to rest for 10 min, followed by a Stroop color word task for 20 min. After the task, the subjects were instructed to rest for 120 min. For all subjects, R-R interval data were collected; analysis was performed for VLF, HF, and LF/HF ratio. HRV during the rest time and each 15-min interval of the recovery time were compared. An analysis of the covariance was performed to adjust for the HF band and LF/HF ratio as confounding variables of the VLF component. HF and VLF bands significantly decreased and the LF/HF ratio significantly increased during the task compared with those during rest time. During recovery, the VLF band was significantly decreased compared with the rest time. After the task, the HF band and LF/HF ratio immediately returned to baseline and were not significantly different from the resting values. After adjusting for HF and LF/HF ratio, the VLF band had significantly decreased compared with that during rest. The VLF band is the "slow recovery" component and the HF band and LF/HF ratio are the "quick recovery" components of HRV. This VLF characteristic may clarify the unexplained association of the VLF band in cardiovascular disease prevention.

  1. The very low-frequency band of heart rate variability represents the slow recovery component after a mental stress task.

    Science.gov (United States)

    Usui, Harunobu; Nishida, Yusuke

    2017-01-01

    The very low-frequency (VLF) band of heart rate variability (HRV) has different characteristics compared with other HRV components. Here we investigated differences in HRV changes after a mental stress task. After the task, the high-frequency (HF) band and ratio of high- to low-frequency bands (LF/HF) immediately returned to baseline. We evaluated the characteristics of VLF band changes after a mental stress task. We hypothesized that the VLF band decreases during the Stroop color word task and there would be a delayed recovery for 2 h after the task (i.e., the VLF change would exhibit a "slow recovery"). Nineteen healthy, young subjects were instructed to rest for 10 min, followed by a Stroop color word task for 20 min. After the task, the subjects were instructed to rest for 120 min. For all subjects, R-R interval data were collected; analysis was performed for VLF, HF, and LF/HF ratio. HRV during the rest time and each 15-min interval of the recovery time were compared. An analysis of the covariance was performed to adjust for the HF band and LF/HF ratio as confounding variables of the VLF component. HF and VLF bands significantly decreased and the LF/HF ratio significantly increased during the task compared with those during rest time. During recovery, the VLF band was significantly decreased compared with the rest time. After the task, the HF band and LF/HF ratio immediately returned to baseline and were not significantly different from the resting values. After adjusting for HF and LF/HF ratio, the VLF band had significantly decreased compared with that during rest. The VLF band is the "slow recovery" component and the HF band and LF/HF ratio are the "quick recovery" components of HRV. This VLF characteristic may clarify the unexplained association of the VLF band in cardiovascular disease prevention.

  2. Advances in Ka-Band Communication System for CubeSats and SmallSats

    Science.gov (United States)

    Kegege, Obadiah; Wong, Yen F.; Altunc, Serhat

    2016-01-01

    A study was performed that evaluated the feasibility of Ka-band communication system to provide CubeSat/SmallSat high rate science data downlink with ground antennas ranging from the small portable 1.2m/2.4m to apertures 5.4M, 7.3M, 11M, and 18M, for Low Earth Orbit (LEO) to Lunar CubeSat missions. This study included link analysis to determine the data rate requirement, based on the current TRL of Ka-band flight hardware and ground support infrastructure. Recent advances in Ka-band transceivers and antennas, options of portable ground stations, and various coverage distances were included in the analysis. The link/coverage analysis results show that Cubesat/Smallsat missions communication requirements including frequencies and data rates can be met by utilizing Near Earth Network (NEN) Ka-band support with 2 W and high gain (>6 dBi) antennas.

  3. UWB Filtering Power Divider with Two Narrow Notch-bands and Wide Stop-band

    Science.gov (United States)

    Wei, Feng; Wang, Xin-Yi; Zou, Xin Tong; Shi, Xiao Wei

    2017-12-01

    A compact filtering ultra-wideband (UWB) microstrip power divider (PD) with two sharply rejected notch-bands and wide stopband is analyzed and designed in this paper. The proposed UWB PD is based on a conventional Wilkinson power divider, while two stub loaded resonators (SLRs) are coupled into two symmetrical output ports to achieve a bandpass filtering response. The simplified composite right/left-handed (SCRLH) resonators are employed to generate the dual notched bands. Defected ground structure (DGS) is introduced to improve the passband performance. Good insertion/return losses, isolation and notch-band rejection are achieved as demonstrated in both simulation and experiment.

  4. The marginal band system in nymphalid butterfly wings.

    Science.gov (United States)

    Taira, Wataru; Kinjo, Seira; Otaki, Joji M

    2015-01-01

    Butterfly wing color patterns are highly complex and diverse, but they are believed to be derived from the nymphalid groundplan, which is composed of several color pattern systems. Among these pattern systems, the marginal band system, including marginal and submarginal bands, has rarely been studied. Here, we examined the color pattern diversity of the marginal band system among nymphalid butterflies. Marginal and submarginal bands are usually expressed as a pair of linear bands aligned with the wing margin. However, a submarginal band can be expressed as a broken band, an elongated oval, or a single dot. The marginal focus, usually a white dot at the middle of a wing compartment along the wing edge, corresponds to the pupal edge spot, one of the pupal cuticle spots that signify the locations of color pattern organizing centers. A marginal band can be expressed as a semicircle, an elongated oval, or a pair of eyespot-like structures, which suggest the organizing activity of the marginal focus. Physical damage at the pupal edge spot leads to distal dislocation of the submarginal band in Junonia almana and in Vanessa indica, suggesting that the marginal focus functions as an organizing center for the marginal band system. Taken together, we conclude that the marginal band system is developmentally equivalent to other symmetry systems. Additionally, the marginal band is likely a core element and the submarginal band a paracore element of the marginal band system, and both bands are primarily specified by the marginal focus organizing center.

  5. Dosimetry of narrow band UVB treatments

    International Nuclear Information System (INIS)

    Goode, D.H.; Mannering, D.M.

    1996-01-01

    Full text: For many years psoriasis has been treated with broad band UVB lamps. These lamps have a bell shaped spectrum which peaks at 305 nm and extends from 280 nm to 350 nm. However research with monochromatic UV radiation has shown that wavelengths between 300 nm and 320 nm are the most efficacious for clearing psoriasis while wavelengths below 305 nm are most effective for producing the undesirable side effect of erythema (sunburn). In response to these findings Philips developed a narrow band UVB tube in which a large fraction of the output was confined to a narrow peak (bandwidth 2.5 nm) situated at 311 nm. Christchurch Hospital replaced broad band UVB with narrow band treatments in August 1995 and as this required UV exposures to be substantially increased new protocols had to be developed. Three aspects needed to be addressed. These were translating the dose from broad band to narrow band for current patients, determining the initial dose for new patients and developing a formula for increasing subsequent exposures to both types of patient. To translate doses the spectral irradiance (μW/cm 2 /nm) that would fall on the patient was measured in both the old broad band and the new narrow band treatment units and from this UV doses were calculated. All doses were expressed in mJ/cm 2 of unweighted UV over the range 250 nm to 400 nm. The erythemal effectiveness of the two units were compared by using the CIE 1987 curve to express doses in terms of the equivalent exposure of monochromatic 297 nm radiation. It was found that an exposure of 3.96 mJ/cm 2 from the broad band FS40 tubes and 12.79 mJ/cm 2 from the narrow band TL/01 tubes were both equivalent to 1.00 mJ/cm 2 of monochromatic 297 nm radiation so when transferring patients all broad band doses needed to be increased by a factor of 3.2. Before transferring any patients this factor was confirmed by conducting two minimal erythema dose (MED) tests on a normal subject, one in each unit. For new patients a

  6. Fabrication and Testing of Pyramidal X- Band Standard Horn Antenna

    Directory of Open Access Journals (Sweden)

    Hasan F. Khazaal

    2017-11-01

    Full Text Available Standard horn antennas are an important device to evaluate many types of antennas, since they are used as a reference to any type of antennas within the microwave frequency bands. In this project the fabrication process and tests of standard horn antenna operating at X-band frequencies have been proposed. The fabricated antenna passed through multi stages of processing of its parts until assembling the final product. These stages are (milling, bending, fitting and welding. The assembled antenna subjected to two types of tests to evaluate its performance. The first one is the test by two port network analyzer to point out S & Z parameters, input resistance, and the voltage standing wave ratio of the horn, while the second test was done using un-echoic chamber to measure the gain, side lobes level and the half power beam width. The results of testing come nearly as a theoretical value of the most important of antenna parameters, like; gain, side lobe level, -3 dB beam width, return loss and voltage standing wave ratio "VSWR", input Impedance.

  7. 50 MW C-band pulse klystron; 50MW C band pulse klystron

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    C-band pulse klystron E3746 with an output of 50 MW class was developed jointly with the High-Energy Accelerator Research Organization in the Ministry of Education as the klystron for a linear accelerator. For a large-sized linear accelerator in the next generation, a klystron with higher operating frequency has been required to obtain a compact and efficient accelerator. In E3746, the problem of power resistance during high-frequency operation was solved by mounting a traveling-wave multi-cell output circuit. Moreover, stable operation in the pulse width of 2.5 {mu}s and the output of 54 MW was performed at the same operation efficiency (44%) as the conventional S-band tube by using the frequency (in a C-band frequency band) that is two times as high as the conventional general accelerator. (translated by NEDO)

  8. Comparison of band-to-band tunneling models in Si and Si—Ge junctions

    International Nuclear Information System (INIS)

    Jiao Yipeng; Wang Taihuan; Wei Kangliang; Du Gang; Liu Xiaoyan

    2013-01-01

    We compared several different band-to-band tunneling (BTBT) models with both Sentaurus and the two-dimensional full-band Monte Carlo simulator in Si homo-junctions and Si—Ge hetero-junctions. It was shown that in Si homo-junctions, different models could achieve similar results. However, in the Si—Ge hetero-junctions, there were significant differences among these models at high reverse biases (over 2 V). Compared to the nonlocal model, the local models in Sentaurus underrated the BTBT rate distinctly, and the Monte Carlo method was shown to give a better approximation. Additionally, it was found that in the Si region near the interface of the Si—Ge hetero-junctions, the direct tunneling rates increased largely due to the interaction of the band structures of Si and Ge. (semiconductor physics)

  9. Design of Dual-Band Two-Branch-Line Couplers with Arbitrary Coupling Coefficients in Bands

    Directory of Open Access Journals (Sweden)

    I. Prudyus

    2014-12-01

    Full Text Available A new approach to design dual-band two-branch couplers with arbitrary coupling coefficients at two operating frequency bands is proposed in this article. The method is based on the usage of equivalent subcircuits input reactances of the even-mode and odd-mode excitations. The exact design formulas for three options of the dual-band coupler with different location and number of stubs are received. These formulas permit to obtain the different variants for each structure in order to select the physically realizable solution and can be used in broad range of frequency ratio and power division ratio. For verification, three different dual-band couplers, which are operating at 2.4/3.9 GHz with different coupling coefficients (one with 3/6 dB, and 10/3 dB two others are designed, simulated, fabricated and tested. The measured results are in good agreement with the simulated ones.

  10. Band connectivity for topological quantum chemistry: Band structures as a graph theory problem

    Science.gov (United States)

    Bradlyn, Barry; Elcoro, L.; Vergniory, M. G.; Cano, Jennifer; Wang, Zhijun; Felser, C.; Aroyo, M. I.; Bernevig, B. Andrei

    2018-01-01

    The conventional theory of solids is well suited to describing band structures locally near isolated points in momentum space, but struggles to capture the full, global picture necessary for understanding topological phenomena. In part of a recent paper [B. Bradlyn et al., Nature (London) 547, 298 (2017), 10.1038/nature23268], we have introduced the way to overcome this difficulty by formulating the problem of sewing together many disconnected local k .p band structures across the Brillouin zone in terms of graph theory. In this paper, we give the details of our full theoretical construction. We show that crystal symmetries strongly constrain the allowed connectivities of energy bands, and we employ graph theoretic techniques such as graph connectivity to enumerate all the solutions to these constraints. The tools of graph theory allow us to identify disconnected groups of bands in these solutions, and so identify topologically distinct insulating phases.

  11. Band head spin assignment of superdeformed bands in 133Pr using two-parameter formulae

    Science.gov (United States)

    Sharma, Honey; Mittal, H. M.

    2018-03-01

    The two-parameter formulae viz. the power index formula, the nuclear softness formula and the VMI model are adopted to accredit the band head spin (I0) of four superdeformed rotational bands in 133Pr. The technique of least square fitting is used to accredit the band head spin for four superdeformed rotational bands in 133Pr. The root mean deviation among the computed transition energies and well-known experimental transition energies are attained by extracting the model parameters from the two-parameter formulae. The determined transition energies are in excellent agreement with the experimental transition energies, whenever exact spins are accredited. The power index formula coincides well with the experimental data and provides minimum root mean deviation. So, the power index formula is more efficient tool than the nuclear softness formula and the VMI model. The deviation of dynamic moment of inertia J(2) against the rotational frequency is also examined.

  12. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    International Nuclear Information System (INIS)

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration

  13. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    Science.gov (United States)

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration. PMID:24379541

  14. Transport in bilayer and trilayer graphene: band gap engineering and band structure tuning

    Science.gov (United States)

    Zhu, Jun

    2014-03-01

    Controlling the stacking order of atomically thin 2D materials offers a powerful tool to control their properties. Linearly dispersed bands become hyperbolic in Bernal (AB) stacked bilayer graphene (BLG). Both Bernal (ABA) and rhombohedral (ABC) stacking occur in trilayer graphene (TLG), producing distinct band structures and electronic properties. A symmetry-breaking electric field perpendicular to the sample plane can further modify the band structures of BLG and TLG. In this talk, I will describe our experimental effort in these directions using dual-gated devices. Using thin HfO2 film deposited by ALD as gate dielectric, we are able to apply large displacement fields D > 6 V/nm and observe the opening and saturation of the field-induced band gap Eg in bilayer and ABC-stacked trilayer graphene, where the conduction in the mid gap changes by more than six decades. Its field and temperature dependence highlights the crucial role played by Coulomb disorder in facilitating hopping conduction and suppressing the effect of Eg in the tens of meV regime. In contrast, mid-gap conduction decreases with increasing D much more rapidly in clean h-BN dual-gated devices. Our studies also show the evolution of the band structure in ABA-stacked TLG, in particular the splitting of the Dirac-like bands in large D field and the signatures of two-band transport at high carrier densities. Comparison to theory reveals the need for more sophisticated treatment of electronic screening beyond self-consistent Hartree calculations to accurately predict the band structures of trilayer graphene and graphenic materials in general.

  15. Impact of oral meloxicam administration before and after band castration on feedlot performance and behavioral response in weanling beef bulls.

    Science.gov (United States)

    Repenning, P E; Ahola, J K; Callan, R J; French, J T; Giles, R L; Bigler, B J; Coetzee, J F; Wulf, L W; Peel, R K; Whittier, J C; Fox, J T; Engle, T E

    2013-10-01

    Two experiments evaluated the effects of band castration and oral administration of an analgesic in association with castration on performance and behavioral and physiological responses in yearling beef bulls. In Exp. 1 Angus and Charolais-crossbred bull calves (n = 127; 309.8 ± 59.04 kg BW) and in Exp. 2 Hereford, Angus, and Hereford × Angus crossbred bulls (n = 30; 300.8 ± 4.96 kg BW) were stratified by BW and randomly assigned to 1 of 3 treatments: 1) band castration (BAND), 2) band castration with oral administration of meloxicam (BAND-MEL), and 3) sham castration (SHAM). The BAND and SHAM procedures were completed on d 0. The SHAM treatment consisted of all animal manipulations associated with band castration without band application. Meloxicam was administered on d -1, 0, and 1 (1.0, 0.5, and 0.5 mg/kg, respectively) via an oral bolus. Body weight and a subjective chute score (CS) were collected on d -1, 0, 1, 7, 14, and 21 (d 28 Exp. 1 only). In Exp. 2, jugular blood samples were collected immediately before castration and 24 h postcastration for substance P (SP) analysis. In Exp. 2, video documentation on d 0 was used to determine range of vertical head motion (DIST) on a subset of animals during treatment administration. In both experiments, ADG was similar (P ≥ 0.50) between BAND and BAND-MEL, but ADG in SHAM cattle was greater (P castrates in Exp. 1 and 2, respectively. In Exp. 1, CS did not differ (P ≥ 0.26) between BAND and BAND-MEL on any day, but castrates exhibited less desirable CS on d 1 and 28 than SHAM cattle. In Exp. 2, CS was not affected (P ≥ 0.41) by castration or the presence of meloxicam. In Exp. 2, DIST did not differ (P = 0.57) between BAND and BAND-MEL, but when pooled, castrates exhibited greater (P = 0.04) DIST than SHAM. In Exp. 2, plasma SP concentrations were similar between BAND and BAND-MEL (P = 0.81) and between castrates vs. sham cattle (P = 0.67). Results indicate no impact of meloxicam administration on performance

  16. Measuring the band structures of periodic beams using the wave superposition method

    Science.gov (United States)

    Junyi, L.; Ruffini, V.; Balint, D.

    2016-11-01

    Phononic crystals and elastic metamaterials are artificially engineered periodic structures that have several interesting properties, such as negative effective stiffness in certain frequency ranges. An interesting property of phononic crystals and elastic metamaterials is the presence of band gaps, which are bands of frequencies where elastic waves cannot propagate. The presence of band gaps gives this class of materials the potential to be used as vibration isolators. In many studies, the band structures were used to evaluate the band gaps. The presence of band gaps in a finite structure is commonly validated by measuring the frequency response as there are no direct methods of measuring the band structures. In this study, an experiment was conducted to determine the band structure of one dimension phononic crystals with two wave modes, such as a bi-material beam, using the frequency response at only 6 points to validate the wave superposition method (WSM) introduced in a previous study. A bi-material beam and an aluminium beam with varying geometry were studied. The experiment was performed by hanging the beams freely, exciting one end of the beams, and measuring the acceleration at consecutive unit cells. The measured transfer function of the beams agrees with the analytical solutions but minor discrepancies. The band structure was then determined using WSM and the band structure of one set of the waves was found to agree well with the analytical solutions. The measurements taken for the other set of waves, which are the evanescent waves in the bi-material beams, were inaccurate and noisy. The transfer functions at additional points of one of the beams were calculated from the measured band structure using WSM. The calculated transfer function agrees with the measured results except at the frequencies where the band structure was inaccurate. Lastly, a study of the potential sources of errors was also conducted using finite element modelling and the errors in

  17. Development of softcopy environment for primary color banding visibility assessment

    Science.gov (United States)

    Min, Byungseok; Pizlo, Zygmunt; Allebach, Jan P.

    2008-01-01

    Fine-pitch banding is one of the most unwanted artifacts in laser electrophotographic (EP) printers. It is perceived as a quasiperiodic fluctuation in the process direction. Therefore, it is essential for printer vendors to know how banding is perceived by humans in order to improve print quality. Monochrome banding has been analyzed and assessed by many researchers; but there is no literature that deals with the banding of color laser printers as measured from actual prints. The study of color banding is complicated by the fact that the color banding signal is physically defined in a three-dimensional color space, while banding perception is described in a one-dimensional sense such as more banding or less banding. In addition, the color banding signal arises from the independent contributions of the four primary colorant banding signals. It is not known how these four distinct signals combine to give rise to the perception of color banding. In this paper, we develop a methodology to assess the banding visibility of the primary colorant cyan based on human visual perception. This is our first step toward studying the more general problem of color banding in combinations of two or more colorants. According to our method, we print and scan the cyan test patch, and extract the banding profile as a one dimensional signal so that we can freely adjust the intensity of banding. Thereafter, by exploiting the pulse width modulation capability of the laser printer, the extracted banding profile is used to modulate a pattern consisting of periodic lines oriented in the process direction, to generate extrinsic banding. This avoids the effect of the halftoning algorithm on the banding. Furthermore, to conduct various banding assessments more efficiently, we also develop a softcopy environment that emulates a hardcopy image on a calibrated monitor, which requires highly accurate device calibration throughout the whole system. To achieve the same color appearance as the hardcopy

  18. Structural Evolution of a Warm Frontal Precipitation Band During GCPEx

    Science.gov (United States)

    Colle, Brian A.; Naeger, Aaron; Molthan, Andrew; Nesbitt, Stephen

    2015-01-01

    A warm frontal precipitation band developed over a few hours 50-100 km to the north of a surface warm front. The 3-km WRF was able to realistically simulate band development, although the model is somewhat too weak. Band genesis was associated with weak frontogenesis (deformation) in the presence of weak potential and conditional instability feeding into the band region, while it was closer to moist neutral within the band. As the band matured, frontogenesis increased, while the stability gradually increased in the banding region. Cloud top generating cells were prevalent, but not in WRF (too stable). The band decayed as the stability increased upstream and the frontogenesis (deformation) with the warm front weakened. The WRF may have been too weak and short-lived with the band because too stable and forcing too weak (some micro issues as well).

  19. Strongly coupled band in 140Gd

    International Nuclear Information System (INIS)

    Falla-Sotelo, F.; Oliveira, J.R.B.; Rao, M.N.

    2005-01-01

    Several high-K states are known to exist in the mass 130-140 region. For the N=74 even-even isotopes, Kπ = 8 - isomers, with lifetimes ranging from ns to ms, are known in 128 Xe, 130 Ba, 132 Ce, 134 Nd, 136 Sm, and 138 Gd[. In 140 Gd, we have observed for the first time a band also based on an Iπ = 8 - state. This could be the first case of a Kπ = 8 - state observed in an N=76 even-even isotope. The systematics of the Kπ = 8 - isomeric states in N=74 isotopes has been studied by A.M. Bruce et al. These states decay towards the K = 0 ground state band, and the transitions are K-forbidden. The 140 Gd case presents strong similarities but also some significant differences with relation to the N=74 isotopes. We propose the same configuration but with larger deformation in 140 Gd

  20. Nanoindentation hardness of banded Australian sedimentary opal

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, P S; Smallwood, A S; Ray, A S [Department of Chemistry, Material and Forensic Science, University of Technology Sydney, PO Box 123, Broadway, NSW 2007 (Australia); Briscoe, B J; Parsonage, D [Department of Chemical Engineering and Chemical Technology, Imperial College of Science, Technology and Medicine, London, SW7 2AZ (United Kingdom)], E-mail: paul.thomas@uts.edu.au

    2008-04-07

    Nanoindentation hardness data in continuous stiffness mode are reported for banded potch and play of colour opals sourced from Lightning Ridge in New South Wales and Andamooka in South Australia. Despite the significant visible heterogeneities observed and the significant differences in origin and microstructures, as observed by SEM, and subtle differences in the elemental distributions between bands within specimens, little difference was observed in the mechanical properties. Specimens were found to be mechanically homogeneous and values of the hardness and moduli were found to be similar between samples. The creep behaviour of the specimens was also observed to be similar. It was concluded that the similarities in mechanical properties were due to the similarities in the silica morphology of the specimens, formed in similar geological environments, as differences in microstructure and trace element distribution were found not to significantly influence the observed bulk mechanical properties.

  1. L-Band RFI in Japan

    Science.gov (United States)

    Soldo, Yan; de Matthaeis, Paolo; Le Vine, David M.

    2016-01-01

    In recent years, three instruments have been launched into orbit with the aim of producing global maps of sea surface salinity and soil moisture using the 1400-1427 MHz band: SMOS, Aquarius and SMAP. Although this frequency band is allocated to passive measurements only, RFI (Radio-Frequency Interference) is present in the data of all three missions. On a global scale, the three sensors have observed approximately the same distribution of RFI. Japan is an important exception that has implications for the design of RFI detection algorithms. RFI in Japan is caused by a large number of emitters belonging to the same system (TV receivers) and for this reason some traditional RFI detection strategies detect little to no RFI over Japan. The study of this case has led to an improvement of the approach to detect RFI in Aquarius data.

  2. X-Band RF Gun Development

    International Nuclear Information System (INIS)

    Vlieks, A.E.

    2012-01-01

    In support of the MEGa-ray program at LLNL and the High Gradient research program at SLAC, a new X-band multi-cell RF gun is being developed. This gun, similar to earlier guns developed at SLAC for Compton X-ray source program, will be a standing wave structure made of 5.5 cells operating in the pi mode with copper cathode. This gun was designed following criteria used to build SLAC X-band high gradient accelerating structures. It is anticipated that this gun will operate with surface electric fields on the cathode of 200 MeV/m with low breakdown rate. RF will be coupled into the structure through a final cell with symmetric duel feeds and with a shape optimized to minimize quadrupole field components. In addition, geometry changes to the original gun, operated with Compton X-ray source, will include a wider RF mode separation, reduced surface electric and magnetic fields.

  3. W-band accelerator study in KEK

    International Nuclear Information System (INIS)

    Zhu Xiongwei; Nakajima, Kazuhisa

    2001-01-01

    In this paper, we summarize the W-band accelerator study in KEK. We present a design study on W-Band photocathode RF gun which is capable of generating and accelerating 300 pC electron bunch. The design system is made up of 91.392 GHz photocathode RF gun and 91.392 GHz traveling wave linac cells. Based on the numerical simulation using SUPERFISH and PARMELA and the conventional RF linac scaling law, the design will produce 300 pC at 1.74 MeV with bunch length 0.72 ps and normalized transverse emittance 0.55 mm mrad. We study the beam dynamics in high frequency and high gradient; due to the high gradient, the pondermotive effect plays an important role in beam dynamics; we found the pondermotive effect still exist with only the fundamental space harmonics (synchrotron mode) due to the coupling of the transverse and longitudinal motion

  4. Band mixing effects in mean field theories

    International Nuclear Information System (INIS)

    Kuyucak, S.; Morrison, I.

    1989-01-01

    The 1/N expansion method, which is an angular momentum projected mean field theory, is used to investigate the nature of electromagnetic transitions in the interacting boson model (IBM). Conversely, comparison with the exact IBM results sheds light on the range of validity of the mean field theory. It is shown that the projected mean field results for the E2 transitions among the ground, β and γ bands are incomplete for the spin dependent terms and it is essential to include band mixing effect for a correct (Mikhailov) analysis of E2 data. The algebraic expressions derived are general and will be useful in the analysis of experimental data in terms of both the sd and sdg boson models. 17 refs., 7 figs., 8 tabs

  5. Band engineering in twisted molybdenum disulfide bilayers

    Science.gov (United States)

    Zhao, Yipeng; Liao, Chengwei; Ouyang, Gang

    2018-05-01

    In order to explore the theoretical relationship between interlayer spacing, interaction and band offset at the atomic level in vertically stacked two-dimensional (2D) van der Waals (vdW) structures, we propose an analytical model to address the evolution of interlayer vdW coupling with random stacking configurations in MoS2 bilayers based on the atomic-bond-relaxation correlation mechanism. We found that interlayer spacing changes substantially with respect to the orientations, and the bandgap increases from 1.53 eV (AB stacking) to 1.68 eV (AA stacking). Our results reveal that the evolution of interlayer vdW coupling originates from the interlayer interaction, leading to interlayer separations and electronic properties changing with stacking configurations. Our predictions constitute a demonstration of twist engineering the band shift in the emergent class of 2D crystals, transition-metal dichalcogenides.

  6. Portable, x-band, linear accelerator systems

    International Nuclear Information System (INIS)

    Schonberg, R.G.; Deruyter, H.; Fowkes, W.R.; Johnson, W.A.; Miller, R.H.; Potter, J.M.; Weaver, J.N.

    1985-01-01

    Three light-weight, x-band, electron accelerators have been developed to provide a series of highly portable sources of x-rays and neutrons for nondestructive testing. The 1.5 MeV x-ray unit has a 200 kW magnetron for an RF source and an air-cooled, traveling wave accelerating structure to minimize its weight. The 4 and 6 MeV units share the same drive system which contains a 1.2 MW magnetron. The 4 MeV unit uses a traveling-wave guide to produce x-rays and the 6MeV unit uses a standing-wave guide to produce x-rays or neutrons. The choice of 9.3 GHz was dictated by the availability of a high power coaxial magnetron and by the obvious dimensional and weight advantages of a higher frequency over the more common S-band frequencies around 3 GHz

  7. Decreasing patient identification band errors by standardizing processes.

    Science.gov (United States)

    Walley, Susan Chu; Berger, Stephanie; Harris, Yolanda; Gallizzi, Gina; Hayes, Leslie

    2013-04-01

    Patient identification (ID) bands are an essential component in patient ID. Quality improvement methodology has been applied as a model to reduce ID band errors although previous studies have not addressed standardization of ID bands. Our specific aim was to decrease ID band errors by 50% in a 12-month period. The Six Sigma DMAIC (define, measure, analyze, improve, and control) quality improvement model was the framework for this study. ID bands at a tertiary care pediatric hospital were audited from January 2011 to January 2012 with continued audits to June 2012 to confirm the new process was in control. After analysis, the major improvement strategy implemented was standardization of styles of ID bands and labels. Additional interventions included educational initiatives regarding the new ID band processes and disseminating institutional and nursing unit data. A total of 4556 ID bands were audited with a preimprovement ID band error average rate of 9.2%. Significant variation in the ID band process was observed, including styles of ID bands. Interventions were focused on standardization of the ID band and labels. The ID band error rate improved to 5.2% in 9 months (95% confidence interval: 2.5-5.5; P error rates. This decrease in ID band error rates was maintained over the subsequent 8 months.

  8. Photon side-bands in mesoscopics

    DEFF Research Database (Denmark)

    Jauho, Antti-Pekka

    1998-01-01

    This paper reviews several applications of photonic side bands, used by Buttiker and Landauer (Phys. Rev. Lett. 49, 1739 (1982)) in their theory of traversal time in tunneling, in transport and optics of mesoscopic systems. Topics include generalizations of the transmission theory of transport...... to time-dependent situations, optics and transport of mesoscopic systems in THz electromagnetic fields, and phase-measurements of photon-assisted tunneling through a quantum dot. (C) 1998 Academic Press Limited....

  9. Identifying chiral bands in real nuclei

    International Nuclear Information System (INIS)

    Shirinda, O.; Lawrie, E.A.

    2012-01-01

    The application of the presently used fingerprints of chiral bands (originally derived for strongly broken chirality) is investigated for real chiral systems. In particular the chiral fingerprints concerning the B(M1) staggering patterns and the energy staggering are studied. It is found that both fingerprints show considerable changes for real chiral systems, a behaviour that creates a significant risk for misinterpretation of the experimental data and can lead to a failure to identify real chiral systems. (orig.)

  10. Large Aperture, Scanning, L-Band SAR

    Science.gov (United States)

    Moussessian, Alina; DelCastillo, Linda; Bach, Vinh; Grando, Maurio; Quijano, Ubaldo; Smith, Phil; Zawadzki, Mark

    2011-01-01

    We have developed the first L-band membrane-based active phased array. The antenna is a 16x16 element patch array with dimensions of 2.3mx2.6m. The array uses membrane-compatible Transmit/Receive (T/R) modules for electronic beam steering. We will discuss the antenna design, the fabrication of this large array, the T/R module development, the signal distribution approach and the measured results of the array

  11. Shifted identical bands: A new phenomenon

    International Nuclear Information System (INIS)

    Jones, E.F.; Lima, A.P. de; Gore, P.M.; Hamilton, J.H.; Ramayya, A.V.; Dodder, R.S.; Kormicki, J.; Hwang, J.K.; Beyer, C.J.; Zhang, X.Q.; Zhu, S.J.; Ter-Akopian, G.M.; Oganessian, Yu.Ts.; Daniel, A.V.; Rasmussen, J.O.; Lee, I.Y.; Cole, J.D.; Drigert, M.W.; Ma, W.-C.

    2001-01-01

    The levels in 162 Gd were identified in spontaneous fission studies. Its transition energies are remarkably similar to those in 160 Gd. From that work, an analysis of yrast bands in even-even proton to neutron-rich Ba to Pb nuclei led to the discovery of a new phenomenon, shifted identical bands (SIB). SIBs are yrast bands in neighboring nuclei (a, b) with moments of inertia which are identical when shifted by a constant amount κ, so J 1a (1 + κ) = J 1b , from 2 + to 8 + and higher to 16 + . Out of over 700 comparisons, 55 SIBs were found from stable to the most neutron-rich Ce-W nuclei with |κ-bar| between 1.5% and 13%, where the spread in κ is less than ± 1%, and only four identical bands (κ-bar congruent with 0). As examples, we found for 158 Sm- 160 Gd, κ-bar (-3.2 +0.1 -0.2 )% (where the ± is the total spread in κ from -3.1 to -3.4); 156 Nd- 160 Gd, (-10.6 +0.4 -0.2 )%; 158 Sm- 160 Sm, (3.4 +0.5 -0.3 )%. The J 1 values were fitted to a variable moment of inertia model with parameters J 0 and C whose values correlate with the SIB J 1 values. The SIBs are not correlated either with deformation or with the N p N n product of the IBA model

  12. Fermion dynamical symmetry and identical bands

    International Nuclear Information System (INIS)

    Guidry, M.

    1994-01-01

    Recent general attention has been directed to the phenomenon of identical bands in both normally deformed and superdeformed nuclei. This paper discusses the possibility that such behavior results from a dynamical symmetry of the nuclear many-body system. Phenomenology and the basic principles of Lie algebras are used to place conditions on the acceptable properties of a candidate symmetry. We find that quite general arguments require that such a symmetry have a minimum of 21 generators with a microscopic fermion interpretation

  13. Broadband S-band class E HPA

    NARCIS (Netherlands)

    Wanum, M.; van Dijk, R.; de Hek, A.P.; van Vliet, Frank Edward

    2009-01-01

    A broadband class E High Power Amplifier (HPA) is presented. This HPA is designed to operate at S-band (2.75 to 3.75 GHz). A power added efficiency of 50% is obtained for the two stage amplifier with an output power of 35.5 dBm on a chip area of 5.25 times 2.8 mm2.

  14. Comparison of eigensolvers for symmetric band matrices.

    Science.gov (United States)

    Moldaschl, Michael; Gansterer, Wilfried N

    2014-09-15

    We compare different algorithms for computing eigenvalues and eigenvectors of a symmetric band matrix across a wide range of synthetic test problems. Of particular interest is a comparison of state-of-the-art tridiagonalization-based methods as implemented in Lapack or Plasma on the one hand, and the block divide-and-conquer (BD&C) algorithm as well as the block twisted factorization (BTF) method on the other hand. The BD&C algorithm does not require tridiagonalization of the original band matrix at all, and the current version of the BTF method tridiagonalizes the original band matrix only for computing the eigenvalues. Avoiding the tridiagonalization process sidesteps the cost of backtransformation of the eigenvectors. Beyond that, we discovered another disadvantage of the backtransformation process for band matrices: In several scenarios, a lot of gradual underflow is observed in the (optional) accumulation of the transformation matrix and in the (obligatory) backtransformation step. According to the IEEE 754 standard for floating-point arithmetic, this implies many operations with subnormal (denormalized) numbers, which causes severe slowdowns compared to the other algorithms without backtransformation of the eigenvectors. We illustrate that in these cases the performance of existing methods from Lapack and Plasma reaches a competitive level only if subnormal numbers are disabled (and thus the IEEE standard is violated). Overall, our performance studies illustrate that if the problem size is large enough relative to the bandwidth, BD&C tends to achieve the highest performance of all methods if the spectrum to be computed is clustered. For test problems with well separated eigenvalues, the BTF method tends to become the fastest algorithm with growing problem size.

  15. Collective oblate bands in Pb nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Huebel, H; Baldsefen, G; Mehta, D [Bonn Univ. (Germany). Inst. fuer Strahlen- und Kernphysik; and others

    1992-08-01

    The coexistence of different nuclear shapes is a well established phenomenon in the Hg-Pb region, where spherical, oblate, prolate and superdeformed prolate shapes have been observed. In this work, the authors report on several new rotational bands in the normally spherical nuclei {sup 199-201}Pb. Similar structures were found previously in the lighter isotopes {sup 197,198}Pb. 11 refs., 1 tab., 3 figs.

  16. ''Identical'' bands in normally-deformed nuclei

    International Nuclear Information System (INIS)

    Garrett, J.D.; Baktash, C.; Yu, C.H.

    1990-01-01

    Gamma-ray transitions energies in neighboring odd- and even-mass nuclei for normally-deformed nuclear configurations are analyzed in a manner similar to recent analyses for superdeformed states. The moment of inertia is shown to depend on pair correlations and the aligned angular momentum of the odd nucleon. The implications of this analysis for ''identical'' super-deformed bands are discussed. 26 refs., 9 figs

  17. Proceedings of wide band gap semiconductors

    International Nuclear Information System (INIS)

    Moustakas, T.D.; Pankove, J.I.; Hamakawa, Y.

    1992-01-01

    This book contains the proceedings of wide band gap semiconductors. Wide band gap semiconductors are under intense study because of their potential applications in photonic devices in the visible and ultraviolet part of the electromagnetic spectrum, and devices for high temperature, high frequency and high power electronics. Additionally, due to their unique mechanical, thermal, optical, chemical, and electronic properties many wide band gap semiconductors are anticipated to find applications in thermoelectric, electrooptic, piezoelectric and acoustooptic devices as well as protective coatings, hard coatings and heat sinks. Material systems covered in this symposium include diamond, II-VI compounds, III-V nitrides, silicon carbide, boron compounds, amorphous and microcrystalline semiconductors, chalcopyrites, oxides and halides. The various papers addressed recent experimental and theoretical developments. They covered issues related to crystal growth (bulk and thin films), structure and microstructure, defects, doping, optoelectronic properties and device applications. A theoretical session was dedicated to identifying common themes in the heteroepitaxy and the role of defects in doping, compensation and phase stability of this unique class of materials. Important experimental milestones included the demonstrations of bright blue injection luminescence at room temperatures from junctions based on III-V nitrides and a similar result from multiple quantum wells in a ZnSe double heterojunction at liquid nitrogen temperatures

  18. Topological magnon bands in ferromagnetic star lattice

    International Nuclear Information System (INIS)

    Owerre, S A

    2017-01-01

    The experimental observation of topological magnon bands and thermal Hall effect in a kagomé lattice ferromagnet Cu(1–3, bdc) has inspired the search for topological magnon effects in various insulating ferromagnets that lack an inversion center allowing a Dzyaloshinskii–Moriya (DM) spin–orbit interaction. The star lattice (also known as the decorated honeycomb lattice) ferromagnet is an ideal candidate for this purpose because it is a variant of the kagomé lattice with additional links that connect the up-pointing and down-pointing triangles. This gives rise to twice the unit cell of the kagomé lattice, and hence more interesting topological magnon effects. In particular, the triangular bridges on the star lattice can be coupled either ferromagnetically or antiferromagnetically which is not possible on the kagomé lattice ferromagnets. Here, we study DM-induced topological magnon bands, chiral edge modes, and thermal magnon Hall effect on the star lattice ferromagnet in different parameter regimes. The star lattice can also be visualized as the parent material from which topological magnon bands can be realized for the kagomé and honeycomb lattices in some limiting cases. (paper)

  19. Topological magnon bands in ferromagnetic star lattice.

    Science.gov (United States)

    Owerre, S A

    2017-05-10

    The experimental observation of topological magnon bands and thermal Hall effect in a kagomé lattice ferromagnet Cu(1-3, bdc) has inspired the search for topological magnon effects in various insulating ferromagnets that lack an inversion center allowing a Dzyaloshinskii-Moriya (DM) spin-orbit interaction. The star lattice (also known as the decorated honeycomb lattice) ferromagnet is an ideal candidate for this purpose because it is a variant of the kagomé lattice with additional links that connect the up-pointing and down-pointing triangles. This gives rise to twice the unit cell of the kagomé lattice, and hence more interesting topological magnon effects. In particular, the triangular bridges on the star lattice can be coupled either ferromagnetically or antiferromagnetically which is not possible on the kagomé lattice ferromagnets. Here, we study DM-induced topological magnon bands, chiral edge modes, and thermal magnon Hall effect on the star lattice ferromagnet in different parameter regimes. The star lattice can also be visualized as the parent material from which topological magnon bands can be realized for the kagomé and honeycomb lattices in some limiting cases.

  20. Surface band structures on Nb(001)

    International Nuclear Information System (INIS)

    Fang, B.; Lo, W.; Chien, T.; Leung, T.C.; Lue, C.Y.; Chan, C.T.; Ho, K.M.

    1994-01-01

    We report the joint studies of experimental and theoretical surface band structures of Nb(001). Angle-resolved photoelectron spectroscopy was used to determine surface-state dispersions along three high-symmetry axes bar Γ bar M, bar Γ bar X, and bar M bar X in the surface Brillouin zone. Ten surface bands have been identified. The experimental data are compared to self-consistent pseudopotential calculations for the 11-layer Nb(001) slabs that are either bulk terminated or fully relaxed (with a 12% contraction for the first interlayer spacing). The band calculations for a 12% surface-contracted slab are in better agreement with the experimental results than those for a bulk-terminated slab, except for a surface resonance near the Fermi level, which is related to the spin-orbit interaction. The charge profiles for all surface states or resonances have been calculated. Surface contraction effects on the charge-density distribution and the energy position of surface states and resonances will also be discussed

  1. Frequency Arrangement For 700 MHz Band

    Directory of Open Access Journals (Sweden)

    Ancans G.

    2015-02-01

    Full Text Available The 694-790 MHz (700 MHz band was allocated by the 2012 World Radiocommunication Conference (WRC-12 in ITU Region 1 (Europe included, to the mobile service on a co-primary basis with other services to which this band was allocated on the primary basis and identified for the International Mobile Telecommunications (IMT. At the same time, the countries of Region 1 will be able also to continue using these frequencies for their broadcasting services if necessary. This allocation will be effective immediately after 2015 World Radiocommunication Conference (WRC-15. In order to make the best possible use of this frequency band for mobile service, a worldwide harmonized frequency arrangement is to be prepared to allow for large economies of scale and international roaming as well as utilizing the available spectrum in the best possible way, minimizing possible interference between services, facilitating deployment and cross-border coordination. The authors analyze different possible frequency arrangements and conclude on the frequency arrangement most suitable for Europe.

  2. Wakefield Band Partitioning in LINAC Structures

    International Nuclear Information System (INIS)

    Jones, Roger M

    2003-01-01

    In the NLC project multiple bunches of electrons and positrons will be accelerated initially to a centre of mass of 500 GeV and later to 1 TeV or more. In the process of accelerating 192 bunches within a pulse train, wakefields are excited which kick the trailing bunches off axis and can cause luminosity dilution and BBU (Beam Break Up). Several structures to damp the wakefield have been designed and tested at SLAC and KEK and these have been found to successfully damp the wakefield [1]. However, these 2π/3 structures suffered from electrical breakdown and this has prompted us to explore lower group velocity structures operating at higher fundamental mode phase advances. The wakefield partitioning amongst the bands has been found to change markedly with increased phase advance. Here we report on general trends in the kick factor and associated wakefield band partitioning in dipole bands as a function of phase advance of the synchronous mode in linacs. These results are applicable to both TW (travelling wave) and SW (standing wave) structures

  3. Pro Et Con Analysis Of Occupational Exposure Assessement Tools And Concepts For nanomaterials

    DEFF Research Database (Denmark)

    Liguori, Biase; Hansen, Steffen Foss; Alstrup Jensen, Keld

    . Examples of these include the "Control Banding Nanotool" developed to assess and control the risks of nanomaterials, the more holistic "Swiss precautionary matrix", and the first order quantitative risk assessment tool, NanoSafer. Here we review these and other tools and we discuss various elements...... of the tools (input data requirements, exposure evaluation and handling to reduce exposure) as well as specific pros and cons. Most of the tools provide a transparent and comprehensible approach to assess occupational exposure, but the majority of them are based on purely qualitative considerations about...... occupational settings. A few methods include specific advice on risk management going well beyond what is normally considered in traditional exposure assessment. A disadvantage in most of the existing concepts is that their data requirements are fairly high. In some cases the technical and scientific...

  4. Tensile-strain effect of inducing the indirect-to-direct band-gap transition and reducing the band-gap energy of Ge

    Energy Technology Data Exchange (ETDEWEB)

    Inaoka, Takeshi, E-mail: inaoka@phys.u-ryukyu.ac.jp; Furukawa, Takuro; Toma, Ryo; Yanagisawa, Susumu [Department of Physics and Earth Sciences, Faculty of Science, University of the Ryukyus, 1 Senbaru, Nishihara, Okinawa 903-0213 (Japan)

    2015-09-14

    By means of a hybrid density-functional method, we investigate the tensile-strain effect of inducing the indirect-to-direct band-gap transition and reducing the band-gap energy of Ge. We consider [001], [111], and [110] uniaxial tensility and (001), (111), and (110) biaxial tensility. Under the condition of no normal stress, we determine both normal compression and internal strain, namely, relative displacement of two atoms in the primitive unit cell, by minimizing the total energy. We identify those strain types which can induce the band-gap transition, and evaluate the critical strain coefficient where the gap transition occurs. Either normal compression or internal strain operates unfavorably to induce the gap transition, which raises the critical strain coefficient or even blocks the transition. We also examine how each type of tensile strain decreases the band-gap energy, depending on its orientation. Our analysis clearly shows that synergistic operation of strain orientation and band anisotropy has a great influence on the gap transition and the gap energy.

  5. Fourteen-Year Long-Term Results after Gastric Banding

    Directory of Open Access Journals (Sweden)

    Christine Stroh

    2011-01-01

    Full Text Available Background. Gastric banding (GB is a common bariatric procedure that is performed worldwide. Weight loss can be substantial after this procedure, but it is not sufficient in a significant portion of patients. Long-term rates for associated complications increase with every year of follow up, and only a few long-term studies have been published that examine these rates. We present our results after 14 years of postoperative follow up. Methods. Two hundred patients were operated upon form 01.02.1995 to 31.01.2009. Data collection was performed prospectively. In retrospective analysis, we analyzed weight loss, short- and long-term complications, amelioration of comorbidities and long-term outcome. Results. The mean postoperative follow up time was 94.4 months (range 2–144. The follow up rate was 83.5%. The incidence of postoperative complications for slippage was 2.5%, for pouch dilatation was 9.5%, for band migration was 5.5% and 12.0% for overall band removal. After 14 years, the reoperation rate was 30.5% with a reoperation rate of 2.2% for every year of follow up. Excess weight loss was 40.2% after 1 year, 46.3% after 2 years, 45.9% after 3 years, 41.9% after five years, 33.3% after 8 years, 30.8% after 10 years, 33.3% after 12 years and 15.6% after 14 years of follow up. Conclusion. The complication and reoperation rate after GB is high. Nevertheless, GB is still a therapeutic option in morbid obese patients, but the criteria for patient selection should be carefully evaluated.

  6. Banding pattern indicative of echinococcosis in a commercial cysticercosis western blot

    Directory of Open Access Journals (Sweden)

    Tappe D

    2009-09-01

    Full Text Available Abstract Objective A commercial cysticercosis Western blot was evaluated for serological cross-reactivity of sera from patients with alveolar (AE and cystic echinococcosis (CE. Methods A total of 161 sera were examined, including 31 sera from AE-patients, 11 sera from CE-patients, 9 sera from patients with other parasitic diseases and 109 sera from patients with unrelated medical conditions. All AE-and CE-sera were also examined by the echinococcosis Western blot. Results More sera from patients with AE than with CE showed cross-reactivity in the form of ladder-like patterns ("Mikado aspect" and untypical bands at 6-8 kDa (71% and 77.4% versus 27.3% and 45.5%, respectively. In contrast, triplets of bands in the area above 50 kDa and between 24 and 39-42 kDa were more frequent in CE than in AE sera. The fuzzy band at 50-55 kDa typical for cysticercosis was absent in all AE and CE sera. Conclusions Atypical banding patterns in the cysticercosis Western blot should raise the suspicion of a metacestode infection different from Taenia solium, i.e. Echinococcus multilocularis or E. granulosus, especially when the Mikado aspect and an altered 6-8 kDa band is visible in the absence of a fuzzy 50-55 kDa band.

  7. An enhanced narrow-band imaging method for the microvessel detection

    Science.gov (United States)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  8. Direct optical band gap measurement in polycrystalline semiconductors: A critical look at the Tauc method

    International Nuclear Information System (INIS)

    Dolgonos, Alex; Mason, Thomas O.; Poeppelmeier, Kenneth R.

    2016-01-01

    The direct optical band gap of semiconductors is traditionally measured by extrapolating the linear region of the square of the absorption curve to the x-axis, and a variation of this method, developed by Tauc, has also been widely used. The application of the Tauc method to crystalline materials is rooted in misconception–and traditional linear extrapolation methods are inappropriate for use on degenerate semiconductors, where the occupation of conduction band energy states cannot be ignored. A new method is proposed for extracting a direct optical band gap from absorption spectra of degenerately-doped bulk semiconductors. This method was applied to pseudo-absorption spectra of Sn-doped In 2 O 3 (ITO)—converted from diffuse-reflectance measurements on bulk specimens. The results of this analysis were corroborated by room-temperature photoluminescence excitation measurements, which yielded values of optical band gap and Burstein–Moss shift that are consistent with previous studies on In 2 O 3 single crystals and thin films. - Highlights: • The Tauc method of band gap measurement is re-evaluated for crystalline materials. • Graphical method proposed for extracting optical band gaps from absorption spectra. • The proposed method incorporates an energy broadening term for energy transitions. • Values for ITO were self-consistent between two different measurement methods.

  9. Photoelectrochemical properties and band structure of oxide films on zirconium-transition metal alloys

    International Nuclear Information System (INIS)

    Takahashi, Kazuo; Uno, Masayoshi; Okui, Mihoko; Yamanaka, Shinsuke

    2006-01-01

    The microalloying effects of 4d and 5d transition metals, M (M: Nb, Mo, Ta, W) on the photoelectrochemical properties, the flat band potential (U fb ) and the band gap energy (E g ), for zirconium oxide films were investigated by photoelectrochemical measurements and band calculation. Button ingots of zirconium-5 mol% M (M: Nb, Mo, Ta, W) were made from high-purity metals (99.9% purity) by arc melting in a purified argon atmosphere. These plate specimens were sealed into silica tubes in vacuum, and then homogenized at 1273 K for 24 h. Subsequently, these specimens were oxidized up to 1173 K. The photocurrent of each specimen was evaluated at room temperature under the irradiation of Xe lamp (500 W) through grating monochrometer and cut-off filter. 0.1 M Na 2 SO 4 solution was used as the electrolyte. The value of the flat band potential was higher and the value of the band gap energy was smaller than that of pure zirconium oxide film in all sample. It was found from the calculation by CASTEP code that the decreases in band gap energy of these oxide films was due to formation of 4d or 5d orbital of transition metals

  10. Generalized seniority scheme for bands in odd-A nuclei

    International Nuclear Information System (INIS)

    Gai, M.; Arima, A.; Strottman, D.

    1980-01-01

    The microscopic generalized seniority scheme is applied for the description of bands in odd-A nuclei. A perturbation expansion in terms of the core-particle interaction is performed. The first-order correction for the band head and the first member of the band is discussed. The specific band structure of a given nucleus, as well as the systematic trend of bands, is described in an explicit N-dependent analytical formula. This formula involves a linear dependence on N which arises from the first-order perturbation expansion. This term is shown responsible for the large deviation of the 11/2 - ΔJ=2 band spacing in I isotopes from the spacing of the Te core. All observed band structures of an odd-A nucleus arise from one simple core-particle coupling. Hence decoupled-E2 bands and strongly coupled ΔJ=1 bands, particle or hole bands of low-spin or high-spin orbits, all follow one simple N-dependence. This uniformity of bands is manifested in E2 bands in 53 I isotopes and deltaJ=1 bands in 51 Sb that have the same 52 Te cores. For the calculations a particle-particle force with a large contribution from a g delta force is used with a coupling constant that is deduced from 210 Pb. 1 figure

  11. Mapping Forest Cover and Forest Cover Change with Airborne S-Band Radar

    Directory of Open Access Journals (Sweden)

    Ramesh K. Ningthoujam

    2016-07-01

    Full Text Available Assessments of forest cover, forest carbon stocks and carbon emissions from deforestation and degradation are increasingly important components of sustainable resource management, for combating biodiversity loss and in climate mitigation policies. Satellite remote sensing provides the only means for mapping global forest cover regularly. However, forest classification with optical data is limited by its insensitivity to three-dimensional canopy structure and cloud cover obscuring many forest regions. Synthetic Aperture Radar (SAR sensors are increasingly being used to mitigate these problems, mainly in the L-, C- and X-band domains of the electromagnetic spectrum. S-band has not been systematically studied for this purpose. In anticipation of the British built NovaSAR-S satellite mission, this study evaluates the benefits of polarimetric S-band SAR for forest characterisation. The Michigan Microwave Canopy Scattering (MIMICS-I radiative transfer model is utilised to understand the scattering mechanisms in forest canopies at S-band. The MIMICS-I model reveals strong S-band backscatter sensitivity to the forest canopy in comparison to soil characteristics across all polarisations and incidence angles. Airborne S-band SAR imagery over the temperate mixed forest of Savernake Forest in southern England is analysed for its information content. Based on the modelling results, S-band HH- and VV-polarisation radar backscatter and the Radar Forest Degradation Index (RFDI are used in a forest/non-forest Maximum Likelihood classification at a spatial resolution of 6 m (70% overall accuracy, κ = 0.41 and 20 m (63% overall accuracy, κ = 0.27. The conclusion is that S-band SAR such as from NovaSAR-S is likely to be suitable for monitoring forest cover and its changes.

  12. Performance characteristics of a perforated shadow band under clear sky conditions

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, Michael J. [School of Mechanical Engineering, University of KwaZulu-Natal, Durban (South Africa)

    2010-12-15

    A perforated, non-rotating shadow band is described for separating global solar irradiance into its diffuse and direct normal components using a single pyranometer. Whereas shadow bands are normally solid so as to occult the sensor of a pyranometer throughout the day, the proposed band has apertures cut from its circumference to intermittently expose the instrument sensor at preset intervals. Under clear sky conditions the device produces a saw tooth waveform of irradiance data from which it is possible to reconstruct separate global and diffuse curves. The direct normal irradiance may then be calculated giving a complete breakdown of the irradiance curves without need of a second instrument or rotating shadow band. This paper describes the principle of operation of the band and gives a mathematical model of its shading mask based on the results of an optical ray tracing study. An algorithm for processing the data from the perforated band system is described and evaluated. In an extended trial conducted at NREL's Solar Radiation Research Laboratory, the band coupled with a thermally corrected Eppley PSP produced independent curves for diffuse, global and direct normal irradiance with low mean bias errors of 5.6 W/m{sup 2}, 0.3 W/m{sup 2} and -2.6 W/m{sup 2} respectively, relative to collocated reference instruments. Random uncertainties were 9.7 W/m{sup 2} (diffuse), 17.3 W/m{sup 2} (global) and 19.0 W/m{sup 2} (direct). When the data processing algorithm was modified to include the ray trace model of sensor exposure, uncertainties increased only marginally, confirming the effectiveness of the model. Deployment of the perforated band system can potentially increase the accuracy of data from ground stations in predominantly sunny areas where instrumentation is limited to a single pyranometer. (author)

  13. INVESTIGATION OF PARALLAX ISSUES FOR MULTI-LENS MULTISPECTRAL CAMERA BAND CO-REGISTRATION

    Directory of Open Access Journals (Sweden)

    J. P. Jhan

    2017-08-01

    Full Text Available The multi-lens multispectral cameras (MSCs, such as Micasense Rededge and Parrot Sequoia, can record multispectral information by each separated lenses. With their lightweight and small size, which making they are more suitable for mounting on an Unmanned Aerial System (UAS to collect high spatial images for vegetation investigation. However, due to the multi-sensor geometry of multi-lens structure induces significant band misregistration effects in original image, performing band co-registration is necessary in order to obtain accurate spectral information. A robust and adaptive band-to-band image transform (RABBIT is proposed to perform band co-registration of multi-lens MSCs. First is to obtain the camera rig information from camera system calibration, and utilizes the calibrated results for performing image transformation and lens distortion correction. Since the calibration uncertainty leads to different amount of systematic errors, the last step is to optimize the results in order to acquire a better co-registration accuracy. Due to the potential issues of parallax that will cause significant band misregistration effects when images are closer to the targets, four datasets thus acquired from Rededge and Sequoia were applied to evaluate the performance of RABBIT, including aerial and close-range imagery. From the results of aerial images, it shows that RABBIT can achieve sub-pixel accuracy level that is suitable for the band co-registration purpose of any multi-lens MSC. In addition, the results of close-range images also has same performance, if we focus on the band co-registration on specific target for 3D modelling, or when the target has equal distance to the camera.

  14. Superdeformed bands in 64147Gd83, a possible test of the existence of octupole correlations in superdeformed bands

    International Nuclear Information System (INIS)

    Zuber, K.; Balouka, D.; Beck, F.A.; Byrski, T.; Curien, D.; Duchene, G.; Gehringer, C.; Haas, B.; Merdinger, J.C.; Romain, P.; Santos, D.; Styczen, J.; Vivien, J.P.; Dudek, J.; Szymanski, Z.; Werner, T.

    1990-01-01

    Two discrete superdeformed bands (SD) have been identified in the nucleus 147 Gd. The transitions energies of the SD yrast band lie halfway between the γ-ray energies of the yrast SD band in 146 Gd while the transition energies of the excited band lie half way between the transition energies of the yrast SD band in 148 Gd. These two bands are shown to exhibit the presence of the pseudo SU(3) symmetry and also indicate the possible existence of octupole correlations at large elongations and high spins. (orig.)

  15. Response of Thematic Mapper bands to plant water stress

    Science.gov (United States)

    Cibula, W. G.; Zetka, E. F.; Rickman, D. L.

    1992-01-01

    Changes in leaf reflectance as water content decreases have been hypothesized to occur in the 1.55-1.75 and 2.08-2.35 micron wavelength regions. To evaluate this hypothesis, studies were conducted on ryegrass (Lolium multiflorum Lam.) and oats (Avena sativa L.), which were grown in a controlled, outdoor situation. Both fully-watered control beds and water-stressed beds were periodically examined with a spectroradiometer calibrated against a reflectance reference of polytetrafluoroethylene. The observed changes correspond to those predicted by stochastic leaf models employed by other investigators (leaf reflection increases in the 1.55-1.75 micron region as leaf water content decreases). Although the percentage changes in TM bands 1-3 are nearly as great as those found in TM bands 5 and 7, the absolute values of reflectance change are much lower. It is believed that these patterns are probably characteristic of a broad range of vegetation types. In terms of phenomena detection, these patterns should be considered in any practical remote sensing sensor scenario.

  16. Quasiparticle semiconductor band structures including spin-orbit interactions.

    Science.gov (United States)

    Malone, Brad D; Cohen, Marvin L

    2013-03-13

    We present first-principles calculations of the quasiparticle band structure of the group IV materials Si and Ge and the group III-V compound semiconductors AlP, AlAs, AlSb, InP, InAs, InSb, GaP, GaAs and GaSb. Calculations are performed using the plane wave pseudopotential method and the 'one-shot' GW method, i.e. G(0)W(0). Quasiparticle band structures, augmented with the effects of spin-orbit, are obtained via a Wannier interpolation of the obtained quasiparticle energies and calculated spin-orbit matrix. Our calculations explicitly treat the shallow semicore states of In and Ga, which are known to be important in the description of the electronic properties, as valence states in the quasiparticle calculation. Our calculated quasiparticle energies, combining both the ab initio evaluation of the electron self-energy and the vector part of the pseudopotential representing the spin-orbit effects, are in generally very good agreement with experimental values. These calculations illustrate the predictive power of the methodology as applied to group IV and III-V semiconductors.

  17. Safety Audit of Band Saw in Manufacturing Organization

    Directory of Open Access Journals (Sweden)

    Martin Kotus

    2016-01-01

    Full Text Available This paper deals with the verifying of safety status for a selected device in the manufacturing organization. The safety audit of band saw was realized in the manufacturing process. Safety requirements of the machinery for cutting material are given in the standard STN 20 0723. This standard from the point of view of the work safety defines selected requirements for sawing, cutting compounds and the using of prevention to work with cutting compounds. Among the basic requirements belong material clamping and security services for cut, band saws and jaws wear, as well as the required protective cover. The efficiency of audit in percentage was evaluated by the level of fulfilment as follows: fulfilled (A mostly fulfilled (AB, conditionally fulfilled (B or unfulfilled (C. Through safety audit, were defined the weaknesses that increase the degree of employee health hazard. There were proposed corrective actions to eliminate weaknesses and retraining employees. It is still needed to perform the safety audit due to reduction of the probability of occupational injury.

  18. Intestinal malrotation and Ladd's bands in a young child | Gaido ...

    African Journals Online (AJOL)

    Intestinal malrotation and Ladd's bands in a young child. ... East African Medical Journal ... potentially more challenging, as it was not the most typical age for duodenal stenosis due to Ladd's bands, which is often mostly observed earlier in life.

  19. Magnetism and magnetostriction in a degenerate rigid band

    International Nuclear Information System (INIS)

    Kulakowski, K.; Barbara, B.

    1990-09-01

    We investigate the influence of the spin-orbit coupling on the magnetic and magnetoelastic phenomena in ferromagnetic band systems. The description is within the Stoner model of a degenerate rigid band, for temperature T = O. (author). 14 refs

  20. Active Multispectral Band Selection and Reflectance Measurement System

    National Research Council Canada - National Science Library

    Rennich, Bradley

    1999-01-01

    .... To aid in the selection of these bands, a novel multispectral band selection technique is presented based on the cross-correlation of the material class reflectance spectra over a wavelength range of 1 - 5 microns...

  1. Assessment of Multipath and Shadowing Effects on UHF Band in ...

    African Journals Online (AJOL)

    Sultan

    bands are used for television broadcasting, mobile cellular systems, Wi-Fi, satellite communications and many others. Effective communication link in the UHF band requires direct line of sight ..... ad-hoc 802.11 wireless LAN (WLAN) devices.

  2. Modeling direct band-to-band tunneling: From bulk to quantum-confined semiconductor devices

    Science.gov (United States)

    Carrillo-Nuñez, H.; Ziegler, A.; Luisier, M.; Schenk, A.

    2015-06-01

    A rigorous framework to study direct band-to-band tunneling (BTBT) in homo- and hetero-junction semiconductor nanodevices is introduced. An interaction Hamiltonian coupling conduction and valence bands (CVBs) is derived using a multiband envelope method. A general form of the BTBT probability is then obtained from the linear response to the "CVBs interaction" that drives the system out of equilibrium. Simple expressions in terms of the one-electron spectral function are developed to compute the BTBT current in two- and three-dimensional semiconductor structures. Additionally, a two-band envelope equation based on the Flietner model of imaginary dispersion is proposed for the same purpose. In order to characterize their accuracy and differences, both approaches are compared with full-band, atomistic quantum transport simulations of Ge, InAs, and InAs-Si Esaki diodes. As another numerical application, the BTBT current in InAs-Si nanowire tunnel field-effect transistors is computed. It is found that both approaches agree with high accuracy. The first one is considerably easier to conceive and could be implemented straightforwardly in existing quantum transport tools based on the effective mass approximation to account for BTBT in nanodevices.

  3. Modeling direct band-to-band tunneling: From bulk to quantum-confined semiconductor devices

    International Nuclear Information System (INIS)

    Carrillo-Nuñez, H.; Ziegler, A.; Luisier, M.; Schenk, A.

    2015-01-01

    A rigorous framework to study direct band-to-band tunneling (BTBT) in homo- and hetero-junction semiconductor nanodevices is introduced. An interaction Hamiltonian coupling conduction and valence bands (CVBs) is derived using a multiband envelope method. A general form of the BTBT probability is then obtained from the linear response to the “CVBs interaction” that drives the system out of equilibrium. Simple expressions in terms of the one-electron spectral function are developed to compute the BTBT current in two- and three-dimensional semiconductor structures. Additionally, a two-band envelope equation based on the Flietner model of imaginary dispersion is proposed for the same purpose. In order to characterize their accuracy and differences, both approaches are compared with full-band, atomistic quantum transport simulations of Ge, InAs, and InAs-Si Esaki diodes. As another numerical application, the BTBT current in InAs-Si nanowire tunnel field-effect transistors is computed. It is found that both approaches agree with high accuracy. The first one is considerably easier to conceive and could be implemented straightforwardly in existing quantum transport tools based on the effective mass approximation to account for BTBT in nanodevices

  4. Modeling direct band-to-band tunneling: From bulk to quantum-confined semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo-Nuñez, H.; Ziegler, A.; Luisier, M.; Schenk, A. [Integrated Systems Laboratory ETH Zürich, Gloriastrasse 35, 8092 Zürich (Switzerland)

    2015-06-21

    A rigorous framework to study direct band-to-band tunneling (BTBT) in homo- and hetero-junction semiconductor nanodevices is introduced. An interaction Hamiltonian coupling conduction and valence bands (CVBs) is derived using a multiband envelope method. A general form of the BTBT probability is then obtained from the linear response to the “CVBs interaction” that drives the system out of equilibrium. Simple expressions in terms of the one-electron spectral function are developed to compute the BTBT current in two- and three-dimensional semiconductor structures. Additionally, a two-band envelope equation based on the Flietner model of imaginary dispersion is proposed for the same purpose. In order to characterize their accuracy and differences, both approaches are compared with full-band, atomistic quantum transport simulations of Ge, InAs, and InAs-Si Esaki diodes. As another numerical application, the BTBT current in InAs-Si nanowire tunnel field-effect transistors is computed. It is found that both approaches agree with high accuracy. The first one is considerably easier to conceive and could be implemented straightforwardly in existing quantum transport tools based on the effective mass approximation to account for BTBT in nanodevices.

  5. Cellophane banding for the gradual attenuation of single extrahepatic portosystemic shunts in eleven dogs.

    Science.gov (United States)

    Youmans, K R; Hunt, G B

    1998-08-01

    To evaluate the efficacy and short term effects of a cellophane banding technique for progressive attenuation of canine single extrahepatic portosystemic shunts. A prospective trial of 11 dogs with single congenital extrahepatic shunts. Rectal ammonia tolerance testing and routine biochemical tests were performed preoperatively on all dogs. In seven dogs, preoperative abdominal Doppler ultrasonography was also performed. Exploratory laparotomy revealed a single extrahepatic portocaval shunt in each animal, which was attenuated using a cellophane band with an internal diameter of 2 to 3 mm. The abdomen was closed routinely. Follow-up biochemical analysis and abdominal Doppler ultrasonography or splenoportography were performed postoperatively. The shunt was not amenable to total ligation in 11 dogs, based upon reported criteria. All dogs recovered uneventfully from surgery without evidence of portal hypertension, and showed clinical improvement thereafter. Shunt occlusion was deemed to have occurred in 10 dogs based on resolution of biochemical and/or sonographic abnormalities. One dog continued to have sonographic evidence of portosystemic shunting when evaluated 3 weeks after surgery, despite normal ammonia tolerance, but was lost to subsequent follow-up. Two dogs, in which 3 mm cellophane bands were placed, experienced delayed shunt occlusion. Cellophane banding is simple to perform, and causes progressive attenuation of single extrahepatic shunts in dogs. Further work is needed to determine the maximum diameter of a cellophane band which will produce total attenuation, and the long-term safety and reliability of the treatment.

  6. Simultaneous confidence bands for the integrated hazard function

    OpenAIRE

    Dudek, Anna; Gocwin, Maciej; Leskow, Jacek

    2006-01-01

    The construction of the simultaneous confidence bands for the integrated hazard function is considered. The Nelson--Aalen estimator is used. The simultaneous confidence bands based on bootstrap methods are presented. Two methods of construction of such confidence bands are proposed. The weird bootstrap method is used for resampling. Simulations are made to compare the actual coverage probability of the bootstrap and the asymptotic simultaneous confidence bands. It is shown that the equal--tai...

  7. Microscopic description of the three major bands in transitional nuclei

    International Nuclear Information System (INIS)

    Pineda S, R.L.

    1986-01-01

    The author has extended the Coherent Phonon Model to the description of the three major bands in medium heavy transitional nuclei. The model assumes an axially symmetric deformed ground intrinsic state for the description of the low lying yrast levels of the ground band, while the excited bands are generated by intrinsic excitations of the ground band. Good angular momentum states are generated by the Peierls-Yoccoz angular momentum projection method

  8. Identical bands in Ba-Dy, N < 104 space

    International Nuclear Information System (INIS)

    Mittal, H.M.; Vidya Devi; Gupta, J.B.

    2008-01-01

    The recognition of the existence of identical bands, in even-even, odd-even and odd-odd nuclei, in normal deformed bands and superdeformed bands has become the subject of great interest in recent years. Here the search have been taken for such bands for the normal deformed, even-Z, even-N nuclei of Ba and Dy for 82< N<104 major shell space

  9. Vortex excitations and identical superdeformed bands

    Energy Technology Data Exchange (ETDEWEB)

    Waddington, J C; Bhaduri, R K [McMaster Univ., Hamilton, ON (Canada). Dept. of Physics

    1992-08-01

    Striking relationships exist amongst the transition energies of the identical superdeformed bands (SDB). In this paper, the authors suggest that all of these bands in both the mass 150 and mass 190 regions can be explained as excitations of the specially stable doubly closed shell {sup 152}Dy. Typical of these bands is the case of {sup 153}Dy. Two excited SDB`s were observe which not only have a moment of inertia identical to that of {sup 152}Dy, but the transition energies are shifted by exactly {+-}1/4 of a rotational spacing. It is as though the spin 1/2 of the last neutron had been added directly to the angular momentum of the core, but the mass of this last particle had not contributed to the moment of inertia. The possibility is being investigated that the identical SDBs arise from an equivalent picture under the strong rotation of the specially stable {sup 152}Dy. The rotation renders the 3-dimensional space topologically nontrivial. The moment of inertia of {sup 192}Hg extrapolated to zero spin is identical to that of {sup 152}Dy at high spin. This suggests that a superfluid is formed as particles are added to {sup 152}Dy to make {sup 192}Hg. It is proposed that as the rotational frequency of {sup 192}Hg is increased, quantized vortices are formed, like vortices in superfluid {sup 4}He. These vortices lead to an additional alignment in{sup 192}Hg relative to the {sup 152} core, increasing as I{sup 2}, reaching a value of 4{Dirac_h} at I = 48. 3 refs., 3 figs.

  10. Thermodynamics of many-band superconductors

    International Nuclear Information System (INIS)

    Waelte, A.

    2006-01-01

    In the present thesis the microscopical properties of the superconducting state of MgCNi 3 , MgB 2 , and some rare earth-transition metal borocarbides are studied by means of measurements of the specific heat. Furthermore the frequency spectrum of the lattice vibrations is estimated. The energy gap of the superconducting state can be determined from the specific heat of the superconducting state, which yields as like as the upper critical mafnetic field H c2 (0) hints on the electron-phonon coupling. From the analysis of these results and the comparison with results from transport measurements as well as the tunnel and point-contact spectroscopy can be concluded, how far the BCS model of superconductivity must be modified in order to be able to describe the superconducting state of the studied compounds. Studies on MgCNi 3 , which lies near a magnetic instability, show that occurring magnetic fluctuations have a bisection of the superconducting transition temperature T C as consequence. The under this aspect relatively high value of T C =7 K is a consequence of strong electron-phonon coupling, which is essentailly carried by nickel vibrations stabilized by carbon. A for the first time observed distinct anomaly in the specific heat of the classical many-band superconductor MgB 2 (here with pure 10 B) at about T c /4=10 K can be understood by means of a two-band model for the case of especially weak coupling between both bands. The analysis of the specific heat of the superconducting phase of the non-magnetic rare earth-nickel borocarbide YNi 2 B 2 C and LuNi 2 B 2 C leads to the conclusion thet visible effects of the many-band electron system are dependent on the mass on the position both of the rare earth and the transition metal. The signal of the superconducting phase transformation visible in the specific heat of the antiferromagnetic HoNi 2 B 2 C is smaller than expected

  11. Clear-air lidar dark band

    Science.gov (United States)

    Girolamo, Paolo Di; Scoccione, Andrea; Cacciani, Marco; Summa, Donato; Schween, Jan H.

    2018-04-01

    This paper illustrates measurements carried out by the Raman lidar BASIL in the frame of HOPE, revealing the presence of a clear-air dark band phenomenon (i.e. the appearance of a minimum in lidar backscatter echoes) in the upper portion of the convective boundary layer. The phenomenon is clearly distinguishable in the lidar backscatter echoes at 1064 nm. This phenomenon is attributed to the presence of lignite aerosol particles advected from the surrounding open pit mines in the vicinity of the measuring site.

  12. Fermion dynamical symmetry and identical bands

    International Nuclear Information System (INIS)

    Guidry, M.

    1995-01-01

    Recent general attention has been directed to the phenomenon of identical bands in both normally deformed and superdeformed nuclei. This paper discusses the possibility that such behavior results from a dynamical symmetry of the nuclear many-body system. Phenomenology and the basis principles of Lie algebras are used to place conditions on the acceptable properties of a candidate symmetry. We find that quite general arguments require that such a symmetry have a minimum of 21 generators with a microscopic fermion interpretation. (author). 9 refs., 11 figs., 1 tab

  13. f-band narrowing in uranium intermetallics

    International Nuclear Information System (INIS)

    Dunlap, B.D.; Litterst, F.J.; Malik, S.K.; Kierstead, H.A.; Crabtree, G.W.; Kwok, W.; Lam, D.J.; Mitchell, A.W.

    1987-01-01

    Although the discovery of heavy fermion behavior in uranium compounds has attracted a great deal of attention, relatively little work has been done which is sufficiently systematic to allow an assessment of the relationship of such behavior to more common phenomena, such as mixed valence, narrow-band effects, etc. In this paper we report bulk property measurements for a number of alloys which form a part of such a systematic study. The approach has been to take relatively simple and well-understood materials and alter their behavior by alloying to produce heavy fermion or Kondo behavior in a controlled way

  14. Peristalticity-driven banded chemical garden

    Science.gov (United States)

    Pópity-Tóth, É.; Schuszter, G.; Horváth, D.; Tóth, Á.

    2018-05-01

    Complex structures in nature are often formed by self-assembly. In order to mimic the formation, to enhance the production, or to modify the structures, easy-to-use methods are sought to couple engineering and self-assembly. Chemical-garden-like precipitation reactions are frequently used to study such couplings because of the intrinsic chemical and hydrodynamic interplays. In this work, we present a simple method of applying periodic pressure fluctuations given by a peristaltic pump which can be used to achieve regularly banded precipitate membranes in the copper-phosphate system.

  15. W-Band Sheet Beam Klystron Design

    International Nuclear Information System (INIS)

    Scheitrum, G.; Caryotakis, G.; Burke, A.; Jensen, A.; Jongewaard, E.; Krasnykh, A.; Neubauer, M.; Phillips, R.; Rauenbuehler, K.

    2011-01-01

    Sheet beam devices provide important advantages for very high power, narrow bandwidth RF sources like accelerator klystrons (1). Reduced current density and increased surface area result in increased power capabi1ity, reduced magnetic fields for focusing and reduced cathode loading. These advantages are offset by increased complexity, beam formation and transport issues and potential for mode competition in the ovennoded cavities and drift tube. This paper will describe the design issues encountered in developing a 100 kW peak and 2 kW average power sheet beam k1ystron at W-band including beam formation, beam transport, circuit design, circuit fabrication and mode competition.

  16. Raman band intensities of tellurite glasses.

    Science.gov (United States)

    Plotnichenko, V G; Sokolov, V O; Koltashev, V V; Dianov, E M; Grishin, I A; Churbanov, M F

    2005-05-15

    Raman spectra of TeO2-based glasses doped with WO3, ZnO, GeO2, TiO2, MoO3, and Sb2O3 are measured. The intensity of bands in the Raman spectra of MoO3-TeO2 and MoO3-WO3-TeO2 glasses is shown to be 80-95 times higher than that for silica glass. It is shown that these glasses can be considered as one of the most promising materials for Raman fiber amplifiers.

  17. 77 FR 33098 - Unlicensed Operation in the TV Broadcast Band

    Science.gov (United States)

    2012-06-05

    ...] Unlicensed Operation in the TV Broadcast Band AGENCY: Federal Communications Commission. ACTION: Correcting... matter of ``Unlicensed Operation in the TV Broadcast Band Approval.'' This document contains corrections... of this correction relate to ``Unlicensed Operation in the TV Broadcast Band Approval'' under Sec. 15...

  18. Plasmon band gap generated by intense ion acoustic waves

    International Nuclear Information System (INIS)

    Son, S.; Ku, S.

    2010-01-01

    In the presence of an intense ion acoustic wave, the energy-momentum dispersion relation of plasmons is strongly modified to exhibit a band gap structure. The intensity of an ion acoustic wave might be measured from the band gap width. The plasmon band gap can be used to block the nonlinear cascading channel of the Langmuir wave decay.

  19. Microbial control of Asian longhorned beetles - what are fungal bands?

    Science.gov (United States)

    Ann E. Hajek; Thomas Dubois; Jennifer Lund; Ryan Shanley; Leah Bauer; Michael Smith; Peng Fan; Huang Bo; Hu Jiafu; Zengzhi Li

    2007-01-01

    In Japan, the entomopathogenic fungus Beauveria brongniartii is grown in nonwoven fiber bands that are placed around trunks of orchard trees for control of numerous cerambycid pests, including Anoplophora chinensis (= A. malasiaca). The Japanese company producing bands, Nitto Denko in Osaka, markets bands...

  20. Transistorized wide band pulse amplifier; Amplificateur d'impulsions a large bande et a transistors

    Energy Technology Data Exchange (ETDEWEB)

    Girard, J; Savinelli, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Hazoni, Y [Atomic Energy Commission (Israel)

    1960-07-01

    A simple wide band amplifier is described below, having a stability better than 1{sup 0}/00 deg{sup -1} centigrade, a current gain of 10{sup 3}, bandwidth of 30 MHz, and a signal to noise current ratio of about 100. This amplifier has been studied to answer the necessity of a fast transistor head amplifier for nuclear detectors, having in mind pile up and overloading problems. (author) [French] Un amplificateur simple, a large bande, est decrit ci-apres, il a une stabilite meilleure que le 0/00 par degre centigrade, un gain en courant de 10{sup 3} une largeur de bande de 30 MHz, et un rapport signal sur bruit en courant d'environ 100. Cet amplificateur a ete etudie pour repondre a la necessite de l'amplification des impulsions provenant de detecteurs nucleaires, ayant a l'esprit les problemes d'empilement et de saturation. (auteur)

  1. Band head spin assignment of superdeformed bands in Hg isotopes through power index formula

    Science.gov (United States)

    Sharma, Honey; Mittal, H. M.

    2018-05-01

    The power index formula has been used to obtain the band head spin (I 0) of all the superdeformed (SD) bands in Hg isotopes. A least squares fitting approach is used. The root mean square deviations between the determined and the observed transition energies are calculated by extracting the model parameters using the power index formula. Whenever definite spins are available, the determined and the observed transition energies are in accordance with each other. The computed values of dynamic moment of inertia J (2) obtained by using the power index formula and its deviation with the rotational frequency is also studied. Excellent agreement is shown between the calculated and the experimental results for J (2) versus the rotational frequency. Hence, the power index formula works very well for all the SD bands in Hg isotopes expect for 195Hg(2, 3, 4).

  2. One-stage release of congenital constriction band in lower limb from new born to 3 years

    Directory of Open Access Journals (Sweden)

    Das Sakti

    2010-01-01

    Full Text Available Background: Congenital constriction band is the most common cause of terminal congenital malformation of a limb and lymphoedema. Superficial bands do not need any treatment, but deeper bands are managed with excision and Z-plasty. The circumferential bands are released in two to three stages to prevent vascular compromise. The purpose of this study was to present the outcome of one-stage release. Materials and Methods: Nineteen children, 12 boys and 7 girls, with 24 congenital constriction bands constituted the clinical material. The mean age at presentation was 57 days (range 12 hours to 3 years Band was unilateral in 14 and bilateral in five limbs. In unilateral cases, right side was involved in nine cases and left side in five. The constriction band is seen at the junction of middle and distal third. The patients having constriction bands in lower limbs and age less than 3 years were included in the study. One stage circumferential release of congenital constriction band was performed. Our youngest patient was operated at the age of six months. Club feet, (n=8 and lymphedema (n=7 were associated anomalies. Club feet and band were released in one stage in three limbs. The results were evaluated by criteria described by Joseph Upton and Cissy Tan. Results: There were 18 excellent, six satisfactory results. No wound problem occurred. No vascular compromise was noted during or after the procedure. On follow-up, distal swelling reduced. Conclusion: One-stage circumferential release of congenital constriction band in lower limbs with or without lymphodema is a safe and easy procedure.

  3. Is biliopancreatic diversion with duodenal switch a solution for patients after laparoscopic gastric banding failure?

    NARCIS (Netherlands)

    Poyck, P. P. C.; Polat, F.; Gouma, D. J.; Hesp, W. L. E. M.

    2012-01-01

    Background: Weight loss failure after laparoscopic gastric banding (LAGB) can occur in <= 25% of patients. Conversion to a malabsorptive procedure might provide more durable weight loss. The present study evaluated biliopancreatic diversion with duodenal switch (BPD/DS) after LAGB failure with a

  4. The Ks-band Tully–Fisher Relation – A Determination of the Hubble ...

    Indian Academy of Sciences (India)

    to 16 galaxy clusters and 218 ScI galaxies with minimum distances of .... In this work, the value of H0 is re-evaluated using the Ks-band TFR and taking ...... research. This research has made use of the NASA/IPAC Extragalactic Database (NED).

  5. Propagation losses in photonic crystal waveguides: Effects of band tail absorption and waveguide dispersion

    DEFF Research Database (Denmark)

    Rigal, F.; Joanesarson, Kristoffer Bitsch; Lyasota, A.

    2017-01-01

    Propagation losses in GaAs-based photonic crystal (PhC) waveguides are evaluated near the semiconductor band-edge by measuring the finesse of corresponding Ln cavities. This approach yields simultaneously the propagation losses and the mode reflectivity at the terminations of the cavities. We dem...

  6. Systematic study of β-band and correlation with g- band using power law and soft rotor formula

    International Nuclear Information System (INIS)

    Katoch, Vikas; Kaushik, Reetu; Sharma, S.; Gupta, J.B.

    2014-01-01

    The nuclear structure of even Z even N medium mass transitional nuclei consist of ground state band, K π =0 1 β-band, K π =2 1 γ- band and other higher bands. As we move away from closed shell, energy levels are low lying from spherical to deformed nuclei and energy deviated from ideal rotor behavior. The energy of these transitional nuclei in ground band can also be studied using Bohr Mottelson energy expression, Soft Rotor Formula (SRF), Power Law (PL) etc. Recently, Gupta et al. (2013) modified SRF for non zero band head K π =2 1 γ-band and reproduced the level energies. Here same formula applied for K π =0 1 β-band and the level energies are reproduced and compared with experimental energies. The power law is also used for recalculation of level energies and for useful comparison

  7. Ka Band Phase Locked Loop Oscillator Dielectric Resonator Oscillator for Satellite EHF Band Receiver

    Directory of Open Access Journals (Sweden)

    S. Coco

    2008-01-01

    Full Text Available This paper describes the design and fabrication of a Ka Band PLL DRO having a fundamental oscillation frequency of 19.250 GHz, used as local oscillator in the low-noise block of a down converter (LNB for an EHF band receiver. Apposite circuital models have been created to describe the behaviour of the dielectric resonator and of the active component used in the oscillator core. The DRO characterization and measurements have shown very good agreement with simulation results. A good phase noise performance is obtained by using a very high Q dielectric resonator.

  8. Higher superdeformed band members in {sup 190}Hg. Evidence for a band interaction

    Energy Technology Data Exchange (ETDEWEB)

    Bearden, I G; Daly, P J [Purdue Univ., Lafayette, IN (United States); Janssens, V F; Carpenter, M P; Ahmad, I; Khoo, T L; Lauritsen, T; Liang, Y [Argonne National Lab., IL (United States); Drigert, M W [Idaho National Engineering Lab., Idaho Falls, ID (United States); Garg, U; Reviol, W [Notre Dame Univ., IN (United States); Wyss, R [Joint Inst. for Heavy Ion Research, Oak Ridge, TN (United States)

    1992-08-01

    The superdeformed band of {sup 190}Hg has been traced up to a frequency {Dirac_h}{omega} {>=} 0.4 MeV by combining data from several experiments. A distinct change in the slope of the dynamic moment of inertia J{sup (2)} vs {Dirac_h}{omega} is observed at {Dirac_h}{omega} 0.32 MeV. This result is interpreted as evidence for a band interaction at the highest frequencies. Possible interpretations are reviewed. (author) 14 refs., 3 figs.

  9. Strongly coupled band in {sup 140}Gd

    Energy Technology Data Exchange (ETDEWEB)

    Falla-Sotelo, F.; Oliveira, J.R.B.; Rao, M.N. [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo (Brazil)] (and others)

    2005-07-01

    Several high-K states are known to exist in the mass 130-140 region. For the N=74 even-even isotopes, K{pi} = 8{sup -} isomers, with lifetimes ranging from ns to ms, are known in {sup 128}Xe, {sup 130}Ba, {sup 132}Ce, {sup 134}Nd, {sup 136}Sm, and {sup 138}Gd[. In {sup 140}Gd, we have observed for the first time a band also based on an I{pi} = 8{sup -} state. This could be the first case of a K{pi} = 8{sup -} state observed in an N=76 even-even isotope. The systematics of the K{pi} = 8{sup -} isomeric states in N=74 isotopes has been studied by A.M. Bruce et al. These states decay towards the K = 0 ground state band, and the transitions are K-forbidden. The {sup 140}Gd case presents strong similarities but also some significant differences with relation to the N=74 isotopes. We propose the same configuration but with larger deformation in {sup 140}Gd.

  10. Symmetries and band gaps in nanoribbons

    Science.gov (United States)

    Zhang, Zhiwei; Tian, Yiteng; Fernando, Gayanath; Kocharian, Armen

    In ideal graphene-like systems, time reversal and sublattice symmetries preserve the degeneracies at the Dirac point(s). We have examined such degeneracies in the band structure as well as the transport properties in various arm-twisted (graphene-related) nanoribbons. A twist angle is defined such that at 0 degrees the ribbon is a rectangular ribbon and at 60 degrees the ribbon is cut from a honeycomb lattice. Using model Hamiltonians and first principles calculations in these nanoribbons with Z2 topology, we have monitored the band structure as a function of the twist angle θ. In twisted ribbons, it turns out that the introduction of an extra hopping term leads to a gap opening. We have also calculated the size and temperature broadening effects in similar ribbons in addition to Rashba-induced transport properties. The authors acknowledge the computing facilities provided by the Center for Functional Nanomaterials, Brookhaven National Laboratory supported by the U.S. Department of Energy, Office of Basic Energy Sciences, under Contract No.DE-AC02- 98CH10886.

  11. Changing optical band structure with single photons

    Science.gov (United States)

    Albrecht, Andreas; Caneva, Tommaso; Chang, Darrick E.

    2017-11-01

    Achieving strong interactions between individual photons enables a wide variety of exciting possibilities in quantum information science and many-body physics. Cold atoms interfaced with nanophotonic structures have emerged as a platform to realize novel forms of nonlinear interactions. In particular, when atoms are coupled to a photonic crystal waveguide, long-range atomic interactions can arise that are mediated by localized atom-photon bound states. We theoretically show that in such a system, the absorption of a single photon can change the band structure for a subsequent photon. This occurs because the first photon affects the atoms in the chain in an alternating fashion, thus leading to an effective period doubling of the system and a new optical band structure for the composite atom-nanophotonic system. We demonstrate how this mechanism can be engineered to realize a single-photon switch, where the first incoming photon switches the system from being highly transmissive to highly reflective, and analyze how signatures can be observed via non-classical correlations of the outgoing photon field.

  12. f-electron systems: pushing band theory

    International Nuclear Information System (INIS)

    Koelling, D.D.

    1991-01-01

    The f-electron orbitrals have always been the ''incomplete atomic shells acting as local moments, and weakly interacting with the remaining electronic structure'' in the minds of most people. So examining them using a band theory where one views them as itinerant was once - and to some extent even today still is - considered with some skepticism. Nonetheless, a very significant community has successfully utilized band theory as a probe of the electronic structure of the appropriate actinides and rare earths. Those people actually using the approach would be the first to declare that it is not the whole solution. Instead, one is pushing and even exceeding its limit of applicability. However, the apropriate procedure is to push the model consistently to its limits, patch where possible, and then look to see where discrepancies remain. I propose to offer a selected review of past developments (emphasizing the career to data of A.J. Freeman in this area), offer a list of interesting puzzles for the future, and then make some guesses as to the techniques one might want to use. (orig.)

  13. Spectra of γ rays feeding superdeformed bands

    International Nuclear Information System (INIS)

    Lauritsen, T.; Khoo, T.L.; Henry, R.G.

    1995-01-01

    The spectrum of γrays coincident with SD transitions contains the transitions which populate the SD band. This spectrum can provide information on the feeding mechanism and on the properties (moment of inertia, collectivity) of excited SD states. We used a model we developed to explain the feeding of SD bands, to calculate the spectrum of feeding γrays. The Monte Carlo simulations take into account the trigger conditions present in our Eurogam experiment. Both experimental and theoretical spectra contain a statistical component and a broad E2 peak (from transitions occurring between excited states in the SD well). There is good resemblance between the measured and calculated spectra although the calculated multiplicity of an E2 bump is low by ∼30%. Work is continuing to improve the quality of the fits, which will result in a better understanding of excited SD states. In addition, a model for the last steps, which cool the γ cascade into the SD yrast line, needs to be developed. A strong M1/E2 low-energy component, which we believe is responsible for this cooling, was observed

  14. Study of intruder band in 112Sn

    International Nuclear Information System (INIS)

    Ganguly, S.; Banerjee, P.; Ray, I.; Kshetri, R.; Raut, R.; Bhattacharya, S.; Saha-Sarkar, M.; Goswami, A.; Mukhopadhyay, S.; Mukherjee, A.; Mukherjee, G.; Basu, S.K.

    2007-01-01

    Excited states of the positive-parity intruder band in 112 Sn, populated in the 100 Mo( 20 Ne,α4n) reaction at a beam energy of 136 MeV, have been studied. The band has been observed up to 11570.0 keV with spin (24 + ). Mean lifetimes have been measured for six states up to the 22 + , 10335.1 keV level and an upper limit of the lifetime has been estimated for the 11570.0 keV (24 + ) state. The B(E2) values, derived from the present lifetime results, correspond to a moderate quadrupole deformation of β 2 ∼0.18 for states with spin J π >=12 + , and the decrease in B(E2) for the 14 + ->12 + transition is consistent with a ν(h 11/2 ) 2 alignment at ω∼0.35 MeV, predicted by a cranked shell-model calculation. Total Routhian surface calculations predict a triaxial shape following the alignment

  15. Valence band photoemission studies of clean metals

    International Nuclear Information System (INIS)

    Wehner, P.S.

    1978-04-01

    The application of Angle-Resolved Photoelectron Spectroscopy (ARPES) to crystalline solids and the utilization of such studies to illuminate several questions concerning the detailed electronic structure of such materials, are discussed. Specifically, by construction of a Direct Transition (DT) model and the utilization of energy-dependent angle-resolved normal photoemission in the photon energy range 32 eV < or = hν < or = 200 eV, the bulk band structure of copper is experimentally mapped out along three different directions in the Brillouin Zone; GAMMA to K, GAMMA to L, and GAMMA to X. In addition, various effects which influence the obtainable resolution in vector k-space, namely, thermal disorder, momentum broadening, and band mixing, are discussed and are shown to place severe limitations on the applicability of the DT model. Finally, a model for Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) based on the symmetry of the initial-state wavefunctions is presented and compared to experimental results obtained from copper single crystals

  16. Spectra of {gamma} rays feeding superdeformed bands

    Energy Technology Data Exchange (ETDEWEB)

    Lauritsen, T.; Khoo, T.L.; Henry, R.G. [and others

    1995-08-01

    The spectrum of {gamma}rays coincident with SD transitions contains the transitions which populate the SD band. This spectrum can provide information on the feeding mechanism and on the properties (moment of inertia, collectivity) of excited SD states. We used a model we developed to explain the feeding of SD bands, to calculate the spectrum of feeding {gamma}rays. The Monte Carlo simulations take into account the trigger conditions present in our Eurogam experiment. Both experimental and theoretical spectra contain a statistical component and a broad E2 peak (from transitions occurring between excited states in the SD well). There is good resemblance between the measured and calculated spectra although the calculated multiplicity of an E2 bump is low by {approximately}30%. Work is continuing to improve the quality of the fits, which will result in a better understanding of excited SD states. In addition, a model for the last steps, which cool the {gamma} cascade into the SD yrast line, needs to be developed. A strong M1/E2 low-energy component, which we believe is responsible for this cooling, was observed.

  17. Portable, x-band, linear accelerator systems

    International Nuclear Information System (INIS)

    Schonberg, R.G.; Deruyter, H.; Fowkes, W.R.; Johnson, W.A.; Miller, R.H.; Potter, J.M.; Weaver, J.N.

    1985-01-01

    Three light-weight, x-band, electron accelerators have been developed to provide a series of highly portable sources of x-rays and neutrons for non-destructive testing. The 1.5 MeV x-ray unit has a 200 kW magnetron for an RF source and an air-cooled, traveling wave accelerating structure to minimize its weight. The 4 and 6 MeV units share the same drive system which contains a 1.2 MW magnetron. The 4 MeV unit uses a traveling-wave guide to produce x-rays and the 6MeV unit uses a standing-wave guide to produce x-rays or neutrons. The choice of 9.3 GHz was dictated by the availability of a high power coaxial magnetron and by the obvious dimensional and weight advantages of a higher frequency over the more common S-band frequencies around 3 GHz

  18. Model of coupled bands in even-even nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Nadzhakov, E G; Nozharov, R M; Myankova, G Z; Antonova, V A [Bylgarska Akademiya na Naukite, Sofia. Inst. za Yadrena Izsledvaniya i Yadrena Energetika

    1979-01-01

    The model is derived in a natural way from the theory of coupled modes. It is based on an expansion of the Hamiltonian in terms of elementary transition operators, including direct rotation-vibration coupling with phonons. The treatment is limited to three types of phonons: ( I = K = 0), S (I = K = 1) and (I = K = 2). The basis of the operators, acting on the ground state is truncated by an inclusion of a reasonable number of phonon states. In the framework of this approximation one may evaluate the matrix elements of the model Hamiltonian and diagonalize it by standard numerical methods to fit the experimental spectrum. The well known picture of band hybridization is obtained as a special case of the model under consideration.

  19. Implementation of Industrial Narrow Band Communication System into SDR Concept

    Directory of Open Access Journals (Sweden)

    A. Prokes

    2008-12-01

    Full Text Available The rapid expansion of the digital signal processing has penetrated recently into a sphere of high performance industrial narrow band communication systems which had been for long years dominated by the traditional analog circuit design. Although it brings new potential to even increase the efficiency of the radio channel usage it also forces new challenges and compromises radio designers have to face. In this article we describe the design of the IF sampling industrial narrowband radio receiver, optimize a digital receiver structure implemented in a single FPGA circuit and study the performance of such radio receiver architecture. As an evaluation criterion the communication efficiency in form of maximum usable receiver sensitivity, co-channel rejection, adjacent channel selectivity and radio blocking measurement have been selected.

  20. Brain alterations in low-frequency fluctuations across multiple bands in obsessive compulsive disorder.

    Science.gov (United States)

    Giménez, Mònica; Guinea-Izquierdo, Andrés; Villalta-Gil, Victoria; Martínez-Zalacaín, Ignacio; Segalàs, Cinto; Subirà, Marta; Real, Eva; Pujol, Jesús; Harrison, Ben J; Haro, Josep Maria; Sato, Joao R; Hoexter, Marcelo Q; Cardoner, Narcís; Alonso, Pino; Menchón, José Manuel; Soriano-Mas, Carles

    2017-12-01

    The extent of functional abnormalities in frontal-subcortical circuits in obsessive-compulsive disorder (OCD) is still unclear. Although neuroimaging studies, in general, and resting-state functional Magnetic Resonance Imaging (rs-fMRI), in particular, have provided relevant information regarding such alterations, rs-fMRI studies have been typically limited to the analysis of between-region functional connectivity alterations at low-frequency signal fluctuations (i.e., <0.08 Hz). Conversely, the local attributes of Blood Oxygen Level Dependent (BOLD) signal across different frequency bands have been seldom studied, although they may provide valuable information. Here, we evaluated local alterations in low-frequency fluctuations across different oscillation bands in OCD. Sixty-five OCD patients and 50 healthy controls underwent an rs-fMRI assessment. Alterations in the fractional amplitude of low-frequency fluctuations (fALFF) were evaluated, voxel-wise, across four different bands (from 0.01 Hz to 0.25 Hz). OCD patients showed decreased fALFF values in medial orbitofrontal regions and increased fALFF values in the dorsal-medial prefrontal cortex (DMPFC) at frequency bands <0.08 Hz. This pattern was reversed at higher frequencies, where increased fALFF values also appeared in medial temporal lobe structures and medial thalamus. Clinical variables (i.e., symptom-specific severities) were associated with fALFF values across the different frequency bands. Our findings provide novel evidence about the nature and regional distribution of functional alterations in OCD, which should contribute to refine neurobiological models of the disorder. We suggest that the evaluation of the local attributes of BOLD signal across different frequency bands may be a sensitive approach to further characterize brain functional alterations in psychiatric disorders.

  1. Warm-Up Activities of Middle and High School Band Directors Participating in State-Level Concert Band Assessments

    Science.gov (United States)

    Ward, Justin P.; Hancock, Carl B.

    2016-01-01

    The purpose of this study was to examine the warm-ups chosen by concert band directors participating in state-level performance assessments. We observed 29 middle and high school bands and coded the frequency and duration of warm-up activities and behaviors. Results indicated that most bands rehearsed music and played scales, long tones, and…

  2. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    Science.gov (United States)

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  3. Band structures in fractal grading porous phononic crystals

    Science.gov (United States)

    Wang, Kai; Liu, Ying; Liang, Tianshu; Wang, Bin

    2018-05-01

    In this paper, a new grading porous structure is introduced based on a Sierpinski triangle routine, and wave propagation in this fractal grading porous phononic crystal is investigated. The influences of fractal hierarchy and porosity on the band structures in fractal graidng porous phononic crystals are clarified. Vibration modes of unit cell at absolute band gap edges are given to manifest formation mechanism of absolute band gaps. The results show that absolute band gaps are easy to form in fractal structures comparatively to the normal ones with the same porosity. Structures with higher fractal hierarchies benefit multiple wider absolute band gaps. This work provides useful guidance in design of fractal porous phononic crystals.

  4. Synthesis of Multispectral Bands from Hyperspectral Data: Validation Based on Images Acquired by AVIRIS, Hyperion, ALI, and ETM+

    Science.gov (United States)

    Blonski, Slawomir; Glasser, Gerald; Russell, Jeffrey; Ryan, Robert; Terrie, Greg; Zanoni, Vicki

    2003-01-01

    Spectral band synthesis is a key step in the process of creating a simulated multispectral image from hyperspectral data. In this step, narrow hyperspectral bands are combined into broader multispectral bands. Such an approach has been used quite often, but to the best of our knowledge accuracy of the band synthesis simulations has not been evaluated thus far. Therefore, the main goal of this paper is to provide validation of the spectral band synthesis algorithm used in the ART software. The next section contains a description of the algorithm and an example of its application. Using spectral responses of AVIRIS, Hyperion, ALI, and ETM+, the following section shows how the synthesized spectral bands compare with actual bands, and it presents an evaluation of the simulation accuracy based on results of MODTRAN modeling. In the final sections of the paper, simulated images are compared with data acquired by actual satellite sensors. First, a Landsat 7 ETM+ image is simulated using an AVIRIS hyperspectral data cube. Then, two datasets collected with the Hyperion instrument from the EO-1 satellite are used to simulate multispectral images from the ALI and ETM+ sensors.

  5. The Keenan and Wing bands in S stars

    International Nuclear Information System (INIS)

    Lambert, D.L.; Clegg, R.E.S.

    1980-01-01

    New observations of the near infrared spectra of S stars are presented as part of a survey of the unidentified Keenan and Wing bands. Bandhead wavelengths accurate to 0.5 A are presented. A new band is found at 9014 A. The bands are not present in normal M giants and dwarfs. Laboratory spectroscopy of heavy element oxides is reported. Several new identifications are proposed. The 10 300 A Wing band is identified with the Δv = - 1 sequence of the ZrO 9300 A Δv = 0 bands. The ZrO B 1 PI-A 1 Δ (Δv = 0) system may be responsible for either the 9736 A or the 10 515 A Wing bands. Two new bands in the near infrared at 8219 and 8235 A are provided by CeO. A new band with heads at 7503 and 7509 A in a spectrum of R And is tentatively attributed to YS. A band at 8268 A in M stars is the TiO delta(2-1) head. The 8610 A Keenan band is not due to CrH. Potential carriers of the Keenan and Wing bands are reviewed. It is suggested that the heavy element sulphides and, perhaps, chlorides are leading candidates. Identification of YS in R And may provide the first evidence for these sulphides. ZrS is a leading candidate for which laboratory spectroscopy is needed. (author)

  6. Reduction in pediatric identification band errors: a quality collaborative.

    Science.gov (United States)

    Phillips, Shannon Connor; Saysana, Michele; Worley, Sarah; Hain, Paul D

    2012-06-01

    Accurate and consistent placement of a patient identification (ID) band is used in health care to reduce errors associated with patient misidentification. Multiple safety organizations have devoted time and energy to improving patient ID, but no multicenter improvement collaboratives have shown scalability of previously successful interventions. We hoped to reduce by half the pediatric patient ID band error rate, defined as absent, illegible, or inaccurate ID band, across a quality improvement learning collaborative of hospitals in 1 year. On the basis of a previously successful single-site intervention, we conducted a self-selected 6-site collaborative to reduce ID band errors in heterogeneous pediatric hospital settings. The collaborative had 3 phases: preparatory work and employee survey of current practice and barriers, data collection (ID band failure rate), and intervention driven by data and collaborative learning to accelerate change. The collaborative audited 11377 patients for ID band errors between September 2009 and September 2010. The ID band failure rate decreased from 17% to 4.1% (77% relative reduction). Interventions including education of frontline staff regarding correct ID bands as a safety strategy; a change to softer ID bands, including "luggage tag" type ID bands for some patients; and partnering with families and patients through education were applied at all institutions. Over 13 months, a collaborative of pediatric institutions significantly reduced the ID band failure rate. This quality improvement learning collaborative demonstrates that safety improvements tested in a single institution can be disseminated to improve quality of care across large populations of children.

  7. Thermoelectric band engineering: The role of carrier scattering

    Science.gov (United States)

    Witkoske, Evan; Wang, Xufeng; Lundstrom, Mark; Askarpour, Vahid; Maassen, Jesse

    2017-11-01

    Complex electronic band structures, with multiple valleys or bands at the same or similar energies, can be beneficial for thermoelectric performance, but the advantages can be offset by inter-valley and inter-band scattering. In this paper, we demonstrate how first-principles band structures coupled with recently developed techniques for rigorous simulation of electron-phonon scattering provide the capabilities to realistically assess the benefits and trade-offs associated with these materials. We illustrate the approach using n-type silicon as a model material and show that intervalley scattering is strong. This example shows that the convergence of valleys and bands can improve thermoelectric performance, but the magnitude of the improvement depends sensitively on the relative strengths of intra- and inter-valley electron scattering. Because anisotropy of the band structure also plays an important role, a measure of the benefit of band anisotropy in the presence of strong intervalley scattering is presented.

  8. Formation of Degenerate Band Gaps in Layered Systems

    Directory of Open Access Journals (Sweden)

    Alexey P. Vinogradov

    2012-06-01

    Full Text Available In the review, peculiarities of spectra of one-dimensional photonic crystals made of anisotropic and/or magnetooptic materials are considered. The attention is focused on band gaps of a special type—the so called degenerate band gaps which are degenerate with respect to polarization. Mechanisms of formation and properties of these band gaps are analyzed. Peculiarities of spectra of photonic crystals that arise due to the linkage between band gaps are discussed. Particularly, it is shown that formation of a frozen mode is caused by linkage between Brillouin and degenerate band gaps. Also, existence of the optical Borrmann effect at the boundaries of degenerate band gaps and optical Tamm states at the frequencies of degenerate band gaps are analyzed.

  9. Emission bands of phosphorus and calculation of band structure of rare earth phosphides

    International Nuclear Information System (INIS)

    Al'perovich, G.I.; Gusatinskij, A.N.; Geguzin, I.I.; Blokhin, M.A.; Torbov, V.I.; Chukalin, V.I.; AN SSSR, Moscow. Inst. Novykh Khimicheskikh Problem)

    1977-01-01

    The method of x-ray emission spectroscopy has been used to investigate the electronic structure of monophosphides of rare-earth metals (REM). The fluorescence K bands of phosphorus have been obtained in LaP, PrP, SmP, GdP, TbP, DyP, HoP, ErP, TmP, YbP, and LuP and also the Lsub(2,3) bands of phosphorus in ErP, TmP, YbP, and LuP. Using the Green function technique involving the muffin-tin potential, the energy spectrum for ErP has been calculated in the single-electron approximation. The hystogram of electronic state distribution N(E) is compared with the experimental K and Lsub(2,3) bands of phosphorus in ErP. The agreement between the main details of N(E) and that of x-ray spectra allows to state that the model used provides a good description of the electron density distribution in crystals of REM monophosphides. In accordance with the character of the N(E) distribution the compounds under study are classified as semimetals or semiconductors with a very narrow forbidden band

  10. Assessment of four shadow band correction models using beam normal irradiance data from the United Kingdom and Israel

    International Nuclear Information System (INIS)

    Lopez, G.; Muneer, T.; Claywell, R.

    2004-01-01

    Diffuse irradiance is a fundamental factor for all solar resource considerations. Diffuse irradiance is accurately determined by calculation from global and beam normal (direct) measurements. However, beam solar measurements and related support can be very expensive, and therefore, shadow bands are often used, along with pyranometers, to block the solar disk. The errors that result from the use of shadow bands are well known and have been studied by many authors. The thrust of this article is to examine four recognized techniques for correcting shadow band based, diffuse irradiance and statistically evaluate their individual performance using data culled from two contrasting sites within the United Kingdom and Israel

  11. New results on the superdeformed {sup 196}Pb nucleus: The decay of the excited bands to the yrast band

    Energy Technology Data Exchange (ETDEWEB)

    Bouneau, S.; Azaiez, F.; Duprat, J. [IPN, Orsay (France)] [and others

    1996-12-31

    The study of the superdeformed (SD) {sup 196}Pb nucleus has been revisited using the EUROGAM phase 2 spectrometer. In addition to the known yrast and two lowest excited SD bands, a third excited SD band has been seen. All of the three excited bands were found to decay to the yrast SD band through, presumably, E1 transitions, allowing relative spin and excitation energy assignments. Comparisons with calculations using the random-phase approximation suggest that all three excited bands can be interpreted as octupole vibrational structures.

  12. Collapse and revival in inter-band oscillations of a two-band Bose-Hubbard model

    Energy Technology Data Exchange (ETDEWEB)

    Ploetz, Patrick; Wimberger, Sandro [Institut fuer Theoretische Physik, Universitaet Heidelberg, Philosophenweg 19, 69120 Heidelberg (Germany); Madronero, Javier, E-mail: ploetz@thphys.uni-heidelberg.d [Physik Department, Technische Universitaet Muenchen, James-Franck-Str. 1, 85748 Garching (Germany)

    2010-04-28

    We study the effect of a many-body interaction on inter-band oscillations in a two-band Bose-Hubbard model with an external Stark force. Weak and strong inter-band oscillations are observed, where the latter arise from a resonant coupling of the bands. These oscillations collapse and revive due to a weak two-body interaction between the atoms. Effective models for oscillations in and out of resonance are introduced that provide predictions for the system's behaviour, particularly for the time scales for the collapse and revival of the resonant inter-band oscillations. (fast track communication)

  13. Coherent optical DFT-spread OFDM transmission using orthogonal band multiplexing.

    Science.gov (United States)

    Yang, Qi; He, Zhixue; Yang, Zhu; Yu, Shaohua; Yi, Xingwen; Shieh, William

    2012-01-30

    Coherent optical OFDM (CO-OFDM) combined with orthogonal band multiplexing provides a scalable and flexible solution for achieving ultra high-speed rate. Among many CO-OFDM implementations, digital Fourier transform spread (DFT-S) CO-OFDM is proposed to mitigate fiber nonlinearity in long-haul transmission. In this paper, we first illustrate the principle of DFT-S OFDM. We then experimentally evaluate the performance of coherent optical DFT-S OFDM in a band-multiplexed transmission system. Compared with conventional clipping methods, DFT-S OFDM can reduce the OFDM peak-to-average power ratio (PAPR) value without suffering from the interference of the neighboring bands. With the benefit of much reduced PAPR, we successfully demonstrate 1.45 Tb/s DFT-S OFDM over 480 km SSMF transmission.

  14. Band structure dynamics in indium wires

    Science.gov (United States)

    Chávez-Cervantes, M.; Krause, R.; Aeschlimann, S.; Gierz, I.

    2018-05-01

    One-dimensional indium wires grown on Si(111) substrates, which are metallic at high temperatures, become insulating below ˜100 K due to the formation of a charge density wave (CDW). The physics of this transition is not conventional and involves a multiband Peierls instability with strong interband coupling. This CDW ground state is readily destroyed with femtosecond laser pulses resulting in a light-induced insulator-to-metal phase transition. The current understanding of this transition remains incomplete, requiring measurements of the transient electronic structure to complement previous investigations of the lattice dynamics. Time- and angle-resolved photoemission spectroscopy with extreme ultraviolet radiation is applied to this end. We find that the transition from the insulating to the metallic band structure occurs within ˜660 fs, which is a fraction of the amplitude mode period. The long lifetime of the transient state (>100 ps) is attributed to trapping in a metastable state in accordance with previous work.

  15. Satellitenbewegung, band III: Natiirliche und gesteuerte bewegung.

    Science.gov (United States)

    Jochim, E. F.

    2014-12-01

    Im dritten Band der Satellitenbewegung werden in fortlaufender Nummerierung einige für Untersuchungen der Bewegung der künstlichen Satelliten wichtige Grundlagen der Astrodynamik mit ausführlichen mathematischen Formelsystemen behandelt. Dazu zählen die unterschiedlichen Aspekte der Bewegung der natürlichen Himmelskörper, die Steuerung und Kontrolle von künstlichen Objekten, und insbesondere die für eine Satellitenbahnanalyse wichtigen physikalischen Beeinflussungen einer Satellitenbewegung. Mathematisch entscheidend ist die Wahl geeigneter Bahnparameter, die ein bestimmtes Bewegungsproblem widerspruchsfrei und singularitätenfrei zu behandeln gestatten. Für die Behandlung routinemäßiger Aufgabenstellungen der Satellitenbewegung, in erster Linie einer präzisen Bahnbestimmung und Bahnverbesserung, kann auf eine Fülle von lehrbuchartigen Monographien verwiesen werden, so dass diese Problematik in der vorliegenden Arbeit nur angedeutet werden soll.

  16. Majorana flat bands in anisotropic systems

    Energy Technology Data Exchange (ETDEWEB)

    Mendler, Daniel; Kotetes, Panagiotis; Schoen, Gerd [Institut fuer theoretische Festkoerperphysik, Karlsruher Institut fuer Technologie (Germany)

    2015-07-01

    It has been recently proposed that topologically protected Majorana flat bands (MFBs) emerge in superconductors with nodal energy spectrum. In this work we introduce a new class of gapful superconductors, in which MFBs can occur due to strong anisotropy. The prototype system exhibiting this kind of behavior is the nematic p{sub x}+p{sub y} spinless superconductor, which supports an edge MFB with controllable bandwidth. Our proposal can be for instance experimentally implemented in topological superconductors engineered from i. semiconductors with tunable spin-orbit coupling or ii. topological insulator surfaces with intrinsic magnetic order in proximity to a conventional SC. By investigating the topological properties of both setups, we show that their unique features render them feasible platforms for manipulating the Majorana fermion bandstructure and realizing MFBs.

  17. Laparoscopic Adjustable Gastric Banding and Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Sigrid Bairdain

    2013-01-01

    Full Text Available Obesity is commonplace, and surgical treatment usually includes Roux-en-Y gastric bypasses (RYGBs. RYGBs have the most documented side effects including vitamin deficiencies, rebound weight gain, and symptomatic hypoglycemia; fewer series exist describing hypoglycemia following other bariatric operations. We reviewed all patients undergoing laparoscopic adjustable gastric banding (LAGB at our institution between 2008 and 2012. Three patients were identified to have symptomatic hypoglycemia following LAGB. Mean time from surgery was 33 months (range 14–45 months, and mean weight loss was 32.7 kg (range 15.9–43.1 kg. None of the patients had preexisting diabetes. Therefore, symptomatic hypoglycemia should be investigated irrespective of bariatric operation.

  18. Two band model for the cuprates

    Science.gov (United States)

    Liu, Shiu; White, Steven

    2009-03-01

    We use a numerical canonical transformation approach to derive an effective two-band model for the hole-doped cuprates, which keeps both oxygen and copper orbitals but removes double occupancy from each. A similar model was considered previously by Frenkel, Gooding, Shraiman, and Siggia (PRB 41, number 1, page 350). We compare the numerically derived model with previously obtained analytical results. In addition to the usual hopping terms between oxygens tpp and Cu-Cu exchange terms Jdd, the model also includes a strong copper-oxygen exchange interaction Jpd and a Kondo-like spin-flip oxygen-oxygen hopping term Kpdp. We use the density matrix renormalization group to study the charge, spin, and pairing properties of the derived model on ladder systems.

  19. High Efficiency Ka-Band Spatial Combiner

    Directory of Open Access Journals (Sweden)

    D. Passi

    2014-12-01

    Full Text Available A Ka-Band, High Efficiency, Small Size Spatial Combiner (SPC is proposed in this paper, which uses an innovatively matched quadruple Fin Lines to microstrip (FLuS transitions. At the date of this paper and at the Author's best knowledge no such FLuS innovative transitions have been reported in literature before. These transitions are inserted into a WR28 waveguide T-junction, in order to allow the integration of 16 Monolithic Microwave Integrated Circuit (MMIC Solid State Power Amplifiers (SSPA's. A computational electromagnetic model using the finite elements method has been implemented. A mean insertion loss of 2 dB is achieved with a return loss better the 10 dB in the 31-37 GHz bandwidth.

  20. Band magnetism due to f-electrons

    International Nuclear Information System (INIS)

    Brodsky, M.B.; Trainor, R.J.

    1976-01-01

    Specific heat data illustrate several types of itinerant or band magnetism in actinide intermetallic compounds. The results show ferromagnetic spin fluctuations in UAl 2 with T/sub sf/ equals 25K, itinerant antiferromagnetism in NpSn 3 with T/sub N/ equals 9.5K and itinerant ferromagnetism in NpOs 2 with T/sub C/ equals 7.9K. Specific heat studies of dilute U/sub 1-x/Th/sub x/Al 2 show the theoretically predicted modifications due to impurity scattering in a spin fluctuation system. For NpSn 3 it is possible to show the BCS nature of the transition due to the gap formation

  1. Theory of Fermi Liquid with Flat Bands

    Science.gov (United States)

    Khodel, V. A.

    2018-04-01

    A self-consistent theory of Fermi systems hosting flat bands is developed. Compared with an original model of fermion condensation, its key point consists in proper accounting for mixing between condensate and non-condensate degrees of freedom that leads to formation of a non-BCS gap Υ (p) in the single-particle spectrum. The results obtained explain: (1) the two-gap structure of spectra of single-particle excitations of electron systems of copper oxides, revealed in ARPES studies, (2) the role of violation of the topological stability of the Landau state in the arrangement of the T-x phase diagram of this family of high-T_c superconductors, (3) the topological nature of a metal-insulator transition, discovered in homogeneous two-dimensional low-density electron liquid of MOSFETs more than 20 years ago.

  2. Design of W-Band photoinjector

    International Nuclear Information System (INIS)

    Zhu, Xiongwei; Nakajima, Kazuhisa

    2000-01-01

    We present a design study on W-Band photocathode RF gun which is capable of generating and accelerating 300 pC electron bunch. The design system is made up of 91.392 GHz photocathode RF gun and 91.392 GHz travelling wave linac cells. Based on the numerical simulation using SUPERFISH and PARMELA and the conventional RF linac scaling law, the design will produce 300 pC at 1.74 MeV with bunch length 0.72 ps and normalized tranverse emittance 0.5 mm mrad. We study the beam dynamics in high frequency and high gradient; due to the high gradient, the pondermotive effect plays an important role in beam dynamics; we found the pondermotive effect still exist with only the fundamental space harmonics (synchrotron mode) due to the coupling of the transverse and longitudinal motion. (author)

  3. The cyanogen band of Comet Halley

    Science.gov (United States)

    Tatum, J. B.; Campbell, E. C.

    The results of improved whole disk solar irradiance spectrum calculations performed for projected Halley's Comet heliocentric radial velocity and distance are provided. The computations were carried out to account for Doppler effects in the Fraunhofer lines of rotational excitation bands of violet CN emissions from the comet in its encounters with solar radiation. The calculations spanned every half-day for 200 days before and after perihelion. The 801 computer images of the expected intensities were photographed in sequence to form an animated film paced by background music from Liszt's Second Hungarian Rhapsody. The results are intended for accounting for spectral changes observed due to Doppler effects induced by changing velocity and distance, rather than physical mechanisms of the emitting processes.

  4. Photonic band gaps of porous solids

    International Nuclear Information System (INIS)

    Biswas, R.; Sigalas, M. M.; Subramania, G.; Soukoulis, C. M.; Ho, K.-M.

    2000-01-01

    Colloidal inverse photonic crystals composed of ordered lattices of air spheres in a high dielectric background are found to have three-dimensional photonic gaps for face-centered cubic, hexgaonal close-packed, and double hexagonal close-packed stacking sequences. Conditions for the occurrence of the complete gap are a sufficient dielectric contrast and a geometry near close packed. Although the lower pseudogaps of these stacking sequences differ, the lowest stop band in the stacking direction is insensitive to the stacking sequence; hence their experimental reflection should be similar. Transmission calculations with structural disorder show the lower pseudogap is relatively unaffected but the higher gap is very difficult to observe with moderate disorder. (c) 2000 The American Physical Society

  5. On the red giant titanium oxide bands

    Science.gov (United States)

    Hanni, L.; Sitska, J.

    1985-12-01

    The dependence of TiO absorption in cool oxygen-sequence giant stars on the Teff and log g of their atmospheres is investigated theoretically on the basis of spectra simulated using the computer program described by Hanni (1983) and the giant model atmospheres of Johnson et al. (1980). The temperature dependence of the intensity jumps at the head of the alpha(1.0) band is determined from simulated spectra, and the jumps are related to spectral types using the calibration of Ridgway et al. (1980). The results are presented in tables and graphs and shown to be in good agreement with the empirical Teff/intensity-jump correlation of Boyarchuk (1969).

  6. Molding of L band niobium superconductor cavity

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Hitoshi; Funahashi, Yoshisato; Saito, Kenji; Noguchi, Shuichi; Koizumi, Susumu [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1995-07-01

    A cavity to produce high accelerating electron field was developed. The L-band (1.3 GHz) niobium superconductor unit cell cavity was ellipsoid with {phi}217.3 mm outer diameter and 2.5 mm thickness and consisted of two pieces of half cell, two beam pipes and flange. A deep drawing process was adapted. In spite of the first trial manufacture, each good cavity was obtained. Characteristic properties of niobium materials, molding method of cavity, extension of sheet after molding, production of beam pipe, accuracy and the cost were explained. Niobium materials. showed tensile strength 15.6 kg/mm{sup 2}, load-carrying capacity 4.1 kg/mm{sup 2}, density 8.57, extension 42.5% and RRR (resistance residual ratio){>=}200. (S.Y.)

  7. Hetero-gate-dielectric double gate junctionless transistor (HGJLT) with reduced band-to-band tunnelling effects in subthreshold regime

    International Nuclear Information System (INIS)

    Ghosh, Bahniman; Mondal, Partha; Akram, M. W.; Bal, Punyasloka; Salimath, Akshay Kumar

    2014-01-01

    We propose a hetero-gate-dielectric double gate junctionless transistor (HGJLT), taking high-k gate insulator at source side and low-k gate insulator at drain side, which reduces the effects of band-to-band tunnelling (BTBT) in the sub-threshold region. A junctionless transistor (JLT) is turned off by the depletion of carriers in the highly doped thin channel (device layer) which results in a significant band overlap between the valence band of the channel region and the conduction band of the drain region, due to off-state drain bias, that triggers electrons to tunnel from the valence band of the channel region to the conduction band of the drain region leaving behind holes in the channel. These effects of band-to-band tunnelling increase the sub-threshold leakage current, and the accumulation of holes in the channel forms a parasitic bipolar junction transistor (n–p–n BJT for channel JLT) in the lateral direction by the source (emitter), channel (base) and drain (collector) regions in JLT structure in off-state. The proposed HGJLT reduces the subthreshold leakage current and suppresses the parasitic BJT action in off-state by reducing the band-to-band tunnelling probability. (semiconductor devices)

  8. Hazard banding in compliance with the new Globally Harmonised System (GHS) for use in control banding tools.

    Science.gov (United States)

    Arnone, Mario; Koppisch, Dorothea; Smola, Thomas; Gabriel, Stefan; Verbist, Koen; Visser, Remco

    2015-10-01

    Many control banding tools use hazard banding in risk assessments for the occupational handling of hazardous substances. The outcome of these assessments can be combined with advice for the required risk management measures (RMMs). The Globally Harmonised System of Classification and Labelling of Chemicals (GHS) has resulted in a change in the hazard communication elements, i.e. Hazard (H) statements instead of Risk-phrases. Hazard banding schemes that depend on the old form of safety information have to be adapted to the new rules. The purpose of this publication is to outline the rationales for the assignment of hazard bands to H statements under the GHS. Based on this, this publication proposes a hazard banding scheme that uses the information from the safety data sheets as the basis for assignment. The assignment of hazard bands tiered according to the severity of the underlying hazards supports the important principle of substitution. Additionally, the set of assignment rules permits an exposure-route-specific assignment of hazard bands, which is necessary for the proposed route-specific RMMs. Ideally, all control banding tools should apply the same assignment rules. This GHS-compliant hazard banding scheme can hopefully help to establish a unified hazard banding strategy in the various control banding tools. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Electronic band structures of binary skutterudites

    International Nuclear Information System (INIS)

    Khan, Banaras; Aliabad, H.A. Rahnamaye; Saifullah; Jalali-Asadabadi, S.; Khan, Imad; Ahmad, Iftikhar

    2015-01-01

    The electronic properties of complex binary skutterudites, MX 3 (M = Co, Rh, Ir; X = P, As, Sb) are explored, using various density functional theory (DFT) based theoretical approaches including Green's Function (GW) as well as regular and non-regular Tran Blaha modified Becke Jhonson (TB-mBJ) methods. The wide range of calculated bandgap values for each compound of this skutterudites family confirm that they are theoretically as challenging as their experimental studies. The computationally expensive GW method, which is generally assume to be efficient in the reproduction of the experimental bandgaps, is also not very successful in the calculation of bandgaps. In this article, the issue of the theoretical bandgaps of these compounds is resolved by reproducing the accurate experimental bandgaps, using the recently developed non-regular TB-mBJ approach, based on DFT. The effectiveness of this technique is due to the fact that a large volume of the binary skutterudite crystal is empty and hence quite large proportion of electrons lie outside of the atomic spheres, where unlike LDA and GGA which are poor in the treatment of these electrons, this technique properly treats these electrons and hence reproduces the clear electronic picture of these compounds. - Highlights: • Theoretical and experimental electronic band structures of binary skutterudites are reviewed. • The literature reveals that none of the existing theoretical results are consistent with the experiments. • GW, regular and non-regular TB-mBJ methods are used to reproduce the correct results. • The GW and regular TB-mBJ results are better than the available results in literature. • However, non-regular TB-mBJ reproduces the correct experimental band structures

  10. Outcome of band ligation in oesophageal varices

    International Nuclear Information System (INIS)

    Abbasi, A.; Bhutto, A.R.; Bhatti, K.I.; Mahmood, K.; Lal, K.

    2013-01-01

    Objective: To find out the outcome og band ligation of oesophageal varices in decompensated chronic liver disease patients. Methods: The quasi experimental study was conducted at the Jinnah Postgraduate Medical Centre, Karachi, and Civil Hospital, Karachi, unit from September 2007 to August 2011. Subjects were eligible if they had a diagnosis of cirrhosis based on history, physical examination, biochemical parameters and liver biopsy in some cases. Patients with advanced cirrhosis (Child-Pugh class C), antibodies against human immunodeficiency virus, hepatocellular carcinoma, portal vein thrombosis evident on ultrasonography, parenteral drug addiction, current alcohol abuse, previous or current treatment with β-blockers were excluded from the study. All patients were asked about alcohol intake and tested to determine the cause of liver cirrhosis. Tests for other causes of cirrhosis were carried out only if there was a suggestive clue. All patients under-went upper gastrointestinal endoscopy after consent. SPSS 15 was used for statistical analysis. Results: The age of the 173 patients who met the inclusion criteria ranged from 15 to 85 years, with a mean of 48.39+-13.38 years. There were 112 (64.7%) males. High-grade varices were seen in 130 (75.1%) patients, while low-grade varices were observed in 43 (24.9%) on first endoscopy. At initial endoscopy, 111 (64.2%) patients had portal hypertensive gastropathy. The patients were followed up for a mean period of 5.20+-2.67 months. Variceal obliteration was achieved in 138 (79.8%), while 33 (19.1%) cases developed re-bleeding. Mean number of endoscopy sessions for these patients were 2.28+-.918 with a maximum of 4. Conclusion: Band ligation eradicated oesophageal varices with less complications and a lower re-bleeding rate, but at the same time eradication was associated with more frequent development of portal hypertensive gastropathy. (author)

  11. Electronic band structures of binary skutterudites

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Banaras [Center for Computational Materials Science, University of Malakand, Chakdara (Pakistan); Department of Physics, University of Malakand, Chakdara (Pakistan); Aliabad, H.A. Rahnamaye [Department of Physics, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); Saifullah [Center for Computational Materials Science, University of Malakand, Chakdara (Pakistan); Department of Physics, University of Malakand, Chakdara (Pakistan); Jalali-Asadabadi, S. [Department of Physics, Faculty of Science, University of Isfahan (UI), 81744 Isfahan (Iran, Islamic Republic of); Khan, Imad [Center for Computational Materials Science, University of Malakand, Chakdara (Pakistan); Department of Physics, University of Malakand, Chakdara (Pakistan); Ahmad, Iftikhar, E-mail: ahma5532@gmail.com [Center for Computational Materials Science, University of Malakand, Chakdara (Pakistan); Department of Physics, University of Malakand, Chakdara (Pakistan)

    2015-10-25

    The electronic properties of complex binary skutterudites, MX{sub 3} (M = Co, Rh, Ir; X = P, As, Sb) are explored, using various density functional theory (DFT) based theoretical approaches including Green's Function (GW) as well as regular and non-regular Tran Blaha modified Becke Jhonson (TB-mBJ) methods. The wide range of calculated bandgap values for each compound of this skutterudites family confirm that they are theoretically as challenging as their experimental studies. The computationally expensive GW method, which is generally assume to be efficient in the reproduction of the experimental bandgaps, is also not very successful in the calculation of bandgaps. In this article, the issue of the theoretical bandgaps of these compounds is resolved by reproducing the accurate experimental bandgaps, using the recently developed non-regular TB-mBJ approach, based on DFT. The effectiveness of this technique is due to the fact that a large volume of the binary skutterudite crystal is empty and hence quite large proportion of electrons lie outside of the atomic spheres, where unlike LDA and GGA which are poor in the treatment of these electrons, this technique properly treats these electrons and hence reproduces the clear electronic picture of these compounds. - Highlights: • Theoretical and experimental electronic band structures of binary skutterudites are reviewed. • The literature reveals that none of the existing theoretical results are consistent with the experiments. • GW, regular and non-regular TB-mBJ methods are used to reproduce the correct results. • The GW and regular TB-mBJ results are better than the available results in literature. • However, non-regular TB-mBJ reproduces the correct experimental band structures.

  12. Change in optimum genetic algorithm solution with changing band discontinuities and band widths of electrically conducting copolymers

    Science.gov (United States)

    Kaur, Avneet; Bakhshi, A. K.

    2010-04-01

    The interest in copolymers stems from the fact that they present interesting electronic and optical properties leading to a variety of technological applications. In order to get a suitable copolymer for a specific application, genetic algorithm (GA) along with negative factor counting (NFC) method has recently been used. In this paper, we study the effect of change in the ratio of conduction band discontinuity to valence band discontinuity (Δ Ec/Δ Ev) on the optimum solution obtained from GA for model binary copolymers. The effect of varying bandwidths on the optimum GA solution is also investigated. The obtained results show that the optimum solution changes with varying parameters like band discontinuity and band width of constituent homopolymers. As the ratio Δ Ec/Δ Ev increases, band gap of optimum solution decreases. With increasing band widths of constituent homopolymers, the optimum solution tends to be dependent on the component with higher band gap.

  13. Amniotic Band Syndrome, Perinatal Hospice, and Palliative Care versus Active Management

    Directory of Open Access Journals (Sweden)

    Shadi Rezai

    2016-01-01

    Full Text Available Introduction. Amniotic band syndrome and sequence are a relatively rare condition in which congenital anomalies occur as a result of the adherence and entrapment of fetal parts with coarse fibrous bands of the amniotic membrane. A large percentage of reported cases have an atypical gestational history. The frequency of this obstetric complication is not affected by fetal gender, genetic abnormality, or prenatal infection. Case. A 21-year-old, G1P0 female parturient at 18 weeks and 5 days with a single intrauterine gestation during a routine ultrasound evaluation was noted to have amniotic band sequence. The pregnancy was subsequently complicated by preterm premature rupture of membranes with oligohydramnios, resulting in a surviving neonate scheduled for rehabilitative treatment. Conclusion. Amniotic band syndrome is an uncommon congenital anomaly resulting in multiple disfiguring and disabling manifestations. Several theories are proposed with most involving early rupture of the amnion and entanglement of fetal parts by amniotic bands. This syndrome can be manifested by development of multiple malformations, with the majority of the defects being limb abnormalities of a disorganized nature, as in the case we present. In the absence of a clear etiology of consequential congenital abnormalities, obstetric management guidelines should use shared decision models to focus on the quality of life for the offspring.

  14. ESR dating at K and X band of northeastern Brazilian megafauna

    International Nuclear Information System (INIS)

    Kinoshita, Angela; Magnolia Franca, Alcina; Augusto Costa de Almeida, Jose; Maria Figueiredo, Ana; Nicolucci, Patricia; Graeff, Carlos F.O.; Baffa, Oswaldo

    2005-01-01

    The archaeological dose (AD) was measured in three tooth samples of giant mammals that belonged to Brazilian megafauna using electron spin resonance (ESR) spectroscopy at X-band (ν ∼9.5GHz) and K-band (ν ∼24GHz). Samples were collected in Lagoa de Dentro, Puxinana city in Paraiba, a northeast state in Brazil and were identified as Haplomastodon waringi (Holland) (two teeth) and one tooth sample of Xenorhinotherium bahiense (Cartele and Lessa). The average AD led to an age for the Haplomastodon samples of 11.6kybp. For one sample (Haplomastodon) K-band was also employed to evaluate the AD. The K-band spectrum had three components, determined using spectral simulation as follows: a wide isotropic line with g factor 2.0048, an orthorhombic line with gx=2.0034, gy=2.0022 and gz=1.9974, and another isotropic line with g factor 2.0008. The amplitude of these three signals increase with the added dose and the average dose found was 26+/-5Gy. This result is compatible with the AD determined with X-band 21+/-3Gy

  15. A comparative in vivo and in vitro L-band EPR study of irradiated rat incisors

    International Nuclear Information System (INIS)

    Zdravkova, M.; Gallez, B.; Debuyst, R.

    2005-01-01

    L-band (∼1GHz) EPR has the potential to measure the absorbed radiation dose in human teeth inside the mouth (in vivo analyses). One crucial point in the development of the method is to know if dosimetry evaluation carried out in vivo after accidental exposures can be reliably based on calibration curves built in vitro. The aim of the present work is to specifically address this point. First, we compared L-band in vitro and in vivo analyses in irradiated rat teeth and estimated the possible loss in in vivo experiments due to rat movements and mouth proximity. Second, the lower pair of rat incisors were analysed by L-band EPR before and after irradiation (50Gy), first on the living rat, then on the same dead rat, finally after extraction of the teeth. X-band powder spectra were also taken after crushing of the two teeth. Irradiations of dead rats and extracted teeth were also carried out. Comparing L-band spectra obtained with living rats and removed heads does not show any significant difference due to possible small rat movements or breathing. Relative standard deviations of the amplitudes of the dosimetric signal are quite high (27-54%). Nevertheless, it seems to be a tendency to have higher signals in irradiated extracted teeth than in irradiated animals

  16. New Kronig-Penney equation emphasizing the band edge conditions

    International Nuclear Information System (INIS)

    Szmulowicz, Frank

    2008-01-01

    The Kronig-Penney problem is a textbook example for discussing band dispersions and band gap formation in periodic layered media. For example, in photonic crystals, the behaviour of bands next to the band edges is important for further discussions of such effects as inhibited light emission, slow light and negative index of refraction. However, the standard Kronig-Penney equation does not explicitly state the band edge conditions. This paper derives a new solution for the Kronig-Penney problem that explicitly displays the band edge conditions as well as contains all other essential physics of band formation. Therefore, the present exposition should show the student that the band edge conditions are not simply special cases of the familiar Kronig-Penney equation but, instead, are an integral part of the band theory. For the computationally minded student, the new equation is particularly convenient for calculating the positions of closely spaced band edges. The present results can be taught alongside the Kronig-Penney equation in advanced undergraduate or beginning graduate quantum mechanics, solid state theory and photonics courses dealing with wave propagation through periodic layered media

  17. Unified bulk-boundary correspondence for band insulators

    Science.gov (United States)

    Rhim, Jun-Won; Bardarson, Jens H.; Slager, Robert-Jan

    2018-03-01

    The bulk-boundary correspondence, a topic of intensive research interest over the past decades, is one of the quintessential ideas in the physics of topological quantum matter. Nevertheless, it has not been proven in all generality and has in certain scenarios even been shown to fail, depending on the boundary profiles of the terminated system. Here, we introduce bulk numbers that capture the exact number of in-gap modes, without any such subtleties in one spatial dimension. Similarly, based on these 1D bulk numbers, we define a new 2D winding number, which we call the pole winding number, that specifies the number of robust metallic surface bands in the gap as well as their topological character. The underlying general methodology relies on a simple continuous extrapolation from the bulk to the boundary, while tracking the evolution of Green's function's poles in the vicinity of the bulk band edges. As a main result we find that all the obtained numbers can be applied to the known insulating phases in a unified manner regardless of the specific symmetries. Additionally, from a computational point of view, these numbers can be effectively evaluated without any gauge fixing problems. In particular, we directly apply our bulk-boundary correspondence construction to various systems, including 1D examples without a traditional bulk-boundary correspondence, and predict the existence of boundary modes on various experimentally studied graphene edges, such as open boundaries and grain boundaries. Finally, we sketch the 3D generalization of the pole winding number by in the context of topological insulators.

  18. NIR-emitting molecular-based nanoparticles as new two-photon absorbing nanotools for single particle tracking

    Science.gov (United States)

    Daniel, J.; Godin, A. G.; Clermont, G.; Lounis, B.; Cognet, L.; Blanchard-Desce, M.

    2015-07-01

    In order to provide a green alternative to QDs for bioimaging purposes and aiming at designing bright nanoparticles combining both large one- and two-photon brightness, a bottom-up route based on the molecular engineering of dedicated red to NIR emitting dyes that spontaneously form fluorescent organic nanoparticles (FONs) has been implemented. These fully organic nanoparticles built from original quadrupolar dyes are prepared using a simple, expeditious and green protocol that yield very small molecular-based nanoparticles (radius ~ 7 nm) suspension in water showing a nice NIR emission (λem=710 nm). These FONs typically have absorption coefficient more than two orders larger than popular NIR-emitting dyes (such as Alexa Fluor 700, Cy5.5 ….) and much larger Stokes shift values (i.e. up to over 5500 cm-1). They also show very large two-photon absorption response in the 800-1050 nm region (up to about 106 GM) of major promise for two-photon excited fluorescence microscopy. Thanks to their brightness and enhanced photostability, these FONs could be imaged as isolated nanoparticles and tracked using wide-field imaging. As such, thanks to their size and composition (absence of heavy metals), they represent highly promising alternatives to NIR-emitting QDs for use in bioimaging and single particle tracking applications. Moreover, efficient FONs coating was achieved by using a polymeric additive built from a long hydrophobic (PPO) and a short hydrophilic (PEO) segment and having a cationic head group able to interact with the highly negative surface of FONs. This electrostatically-driven interaction promotes both photoluminescence and two-photon absorption enhancement leading to an increase of two-photon brightness of about one order of magnitude. This opens the way to wide-field single particle tracking under two-photon excitation

  19. Modulation of tissue tropism and biological activity of exosomes and other extracellular vesicles : New nanotools for cancer treatment

    NARCIS (Netherlands)

    Kooijmans, Sander A A; Schiffelers, Raymond M.; Zarovni, Natasa; Vago, Riccardo

    2016-01-01

    Exosomes are naturally secreted nanovesicles that have recently aroused a great interest in the scientific and clinical community for their roles in intercellular communication in almost all physiological and pathological processes. These 30–100 nm sized vesicles are released from the cells into the

  20. Preclinical models for an innovative glioblastoma therapeutical strategy by 188Re-SSS encapsulated in nano-tools: translational view

    International Nuclear Information System (INIS)

    Cikankowitz, A.; Belloche, C.; Verger, E.; Garcion, E.; Hindre, F.; Chassain, G.; Fellah, B.; Abadie, J.; Chouin, N.; Ibisch, C.; Davodeau, F.; Couez, D.; Lepareur, N.; Lacoeuille, F.; Menei, P.

    2015-01-01

    Full text of publication follows. Aim: Glioblastoma (GBM) is the most frequent cancer of the nervous system and therapies currently used cannot treat definitively this disease. By the way of NucSan (Nuclear for health) program which supports research development about the use of radio pharmaceutics in oncology, the aim of the proposed work is to provide evidences that internal radiotherapy through lipid nanocapsules loaded with Rhenium-188 (LNC 188 Re-SSS) is an alternative therapeutic strategy for GBM that can be translated to human medicine. Previous works have shown a remarkable efficiency of this tool among syngeneic rats linked with local and peripheral recruitments of the immune system's effectors. In this context, two animal models have been chosen to validate the feasibility of this new innovative therapy design (LNC 188 Re-SSS stereotactic injection). Materials and methods: the syngeneic six weeks old C57BL/6J female mice were treated 6 or 12 days after stereotactic GL261 cells implantation, by a single injection of increasing activities of LNC 188 Re-SSS (0,925; 1,85 and 2,7 MBq/5μl). MRI was used to follow tumor progression to determine the mass volume through the selection of regions of interest. The increased median survival time (IMST) was also assessed for treated mice versus control mice (stereotactic injection of saline solution). For long time survival animals (3 times the median survival time), they were rechallenged through the same procedure in the other hemisphere. The brachy-cephalic dog bearing spontaneous tumor will lead to additional evidences to specifically highlight the potential of this innovative technology for GBM treatment. In order to validate procedures of intracerebral injections, a stereotactic head frame specially designed for dog has been conceived which allow both images acquisition (MRI-SPECT and PET) and the achievement of biopsies. Results/Perspectives: as previously observed on rat models, the preliminary data show interesting results on treatment efficiency in GL261 mice model with the long time survival animals assessed by the absence of tumor progression (IMST: 41%). Thanks to the dog head frame accuracy, brain biopsy targeted by pre/post-surgery MRI has been validated. These two preclinical models will give us additional evidences for a translational approach with the help of CGO-2012 (IRAD) and ANR-12-EMMA-003301 Radiohead projects. They aim at collecting data on in vivo feasibility and efficiency of LNC 188 Re-SSS for GBM treatment, especially in a spontaneous model linked with immune response. Finally, the objective of this work is to set up a phase I/II clinical trial. (authors)

  1. Efficacy of a forearm band in addition to exercises compared with exercises alone for lateral epicondylitis: A multicenter, randomized, controlled trial.

    Science.gov (United States)

    Nishizuka, Takanobu; Iwatsuki, Katsuyuki; Kurimoto, Shigeru; Yamamoto, Michiro; Hirata, Hitoshi

    2017-03-01

    A forearm band is frequently used for lateral epicondylitis worldwide. However, evidence regarding its efficacy has been insufficient. The objective of this prospective, randomized, controlled trial was to analyze the effects of a forearm band for treatment of lateral epicondylitis at 1, 3, 6, and 12 months. Patients with lateral epicondylitis were randomly allocated into a band (n = 55) or non-band (n = 55) group. Patients in the band group were instructed to wear a forearm band for more than 6 h daily for at least 6 months. Patients in both groups were instructed to perform wrist extensor stretching exercises for 30 s, 3 times daily, for 6 months. Hand10, pain, and satisfaction scores, and proportions of positive physical examinations, including tenderness assessment, Thomsen test, and middle finger extension test, were evaluated at 1, 3, 6, and 12 months after enrollment. There were no significant differences between the band and non-band groups with regard to Hand10, pain, or satisfaction scores at 1, 3, 6, and 12 months. Likewise, there was no significant difference in proportions of positive physical examinations between groups at 1, 3, 6, and 12 months. The results of the current study suggest that a forearm band may have no more than a placebo effect, and do not support the use of a forearm band based on its effectiveness. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  2. Deformation potentials for band-to-band tunneling in silicon and germanium from first principles

    Science.gov (United States)

    Vandenberghe, William G.; Fischetti, Massimo V.

    2015-01-01

    The deformation potentials for phonon-assisted band-to-band tunneling (BTBT) in silicon and germanium are calculated using a plane-wave density functional theory code. Using hybrid functionals, we obtain: DTA = 4.1 × 108 eV/cm, DTO = 1.2 × 109 eV/cm, and DLO = 2.2 × 109 eV/cm for BTBT in silicon and DTA = 7.8 × 108 eV/cm and DLO = 1.3 × 109 eV/cm for BTBT in germanium. These values agree with experimentally measured values and we explain why in diodes, the TA/TO phonon-assisted BTBT dominates over LO phonon-assisted BTBT despite the larger deformation potential for the latter. We also explain why LO phonon-assisted BTBT can nevertheless dominate in many practical applications.

  3. Notes on basis band-pass circuits; Notes sur les circuits de base passe-bande

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    Resistor load amplifier stages, basic band-pass RC networks, conventional single-tuned circuits, have the same transfer function. Common properties and differences because diverse magnitude of parameters with proposed problems are exposed. Next the case of several cascaded stages (or networks) is examined when there is no reaction ones to another. (author) [French] Les etages amplificateurs a resistances, les circuits passe-bande RC elementaires, le circuit resonnant classique possedent la meme fonction de transfert. On fait ressortir les proprietes communes et les differences de comportement dues aux ordres de grandeur qu'il est possible de donner aux parametres en fonction des problemes a resoudre. On examine ensuite le cas de plusieurs etages (ou de plusieurs circuits) en cascade lorsqu'ils ne reagissent pas les uns sur les autres. (auteur)

  4. Review of wide band-gap semiconductors technology

    Directory of Open Access Journals (Sweden)

    Jin Haiwei

    2016-01-01

    Full Text Available Silicon carbide (SiC and gallium nitride (GaN are typical representative of the wide band-gap semiconductor material, which is also known as third-generation semiconductor materials. Compared with the conventional semiconductor silicon (Si or gallium arsenide (GaAs, wide band-gap semiconductor has the wide band gap, high saturated drift velocity, high critical breakdown field and other advantages; it is a highly desirable semiconductor material applied under the case of high-power, high-temperature, high-frequency, anti-radiation environment. These advantages of wide band-gap devices make them a hot spot of semiconductor technology research in various countries. This article describes the research agenda of United States and European in this area, focusing on the recent developments of the wide band-gap technology in the US and Europe, summed up the facing challenge of the wide band-gap technology.

  5. Search for positive parity bands in 117Xe

    International Nuclear Information System (INIS)

    Liu, Z.; Sun, X.; Zhou, X.; Lei, X.; Zhang, Y.; Jin, H.; Pan, Q.; Guo, Y.; Chen, X.; Luo, Y.; Wen, S.; Yuan, G.; Yang, C.; Luo, W.; Chen, Y.S.; Xing, Z.; Chen, X.Q.

    1995-01-01

    Excited states of 117 Xe were populated via the reaction 28 Si+ 92 Mo at 100-120MeV. More than 40 new γ-transitions and three new positive parity bands have been observed by means of in-beam γ-ray spectroscopy. The previously known νh 11/2 bands were confirmed, and the νg 7/2 favored band was extended up to 47/2 + in which two bandcrossings have been observed at hω=0.33 and 0.44MeV, respectively. The band structures have been discussed by means of TRS and CSM calculations. A newly observed rotational band consisting of five γ-transitions has been considered as the πh 11/2 band of 117 Cs. ((orig.))

  6. Band Structure Characteristics of Nacreous Composite Materials with Various Defects

    Science.gov (United States)

    Yin, J.; Zhang, S.; Zhang, H. W.; Chen, B. S.

    2016-06-01

    Nacreous composite materials have excellent mechanical properties, such as high strength, high toughness, and wide phononic band gap. In order to research band structure characteristics of nacreous composite materials with various defects, supercell models with the Brick-and-Mortar microstructure are considered. An efficient multi-level substructure algorithm is employed to discuss the band structure. Furthermore, two common systems with point and line defects and varied material parameters are discussed. In addition, band structures concerning straight and deflected crack defects are calculated by changing the shear modulus of the mortar. Finally, the sensitivity of band structures to the random material distribution is presented by considering different volume ratios of the brick. The results reveal that the first band gap of a nacreous composite material is insensitive to defects under certain conditions. It will be of great value to the design and synthesis of new nacreous composite materials for better dynamic properties.

  7. Lifetimes of an excited superdeformed band in {sup 192}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I.; Blumenthal, D.; Carpenter, M.P. [and others

    1995-08-01

    An excited superdeformed band was identified in {sup 192}Hg and the lifetimes of its levels measured with the Doppler-shift attenuation method from data taken with the Eurogam spectrometer. The band is proposed to be based on the two-quasineutron (v[642]3/2 [512]5/2) configuration, which after a band crossing, becomes the (v[642]3/2 [752]5/2) configuration. The transition quadrupole moment Q{sub t} of the excited band is the same as that of the yrast SD band, within experimental errors. This suggests that the deformation of the SD minimum is robust with respect to quasiparticle excitation, despite the occupation of the deformation-driving v[752]5/2 level (from the j{sub 15/2} shell) after the band crossing.

  8. Enhancement of phononic band gaps in ternary/binary structure

    International Nuclear Information System (INIS)

    Aly, Arafa H.; Mehaney, Ahmed

    2012-01-01

    Based on the transfer matrix method (TMM) and Bloch theory, the interaction of elastic waves (normal incidence) with 1D phononic crystal had been studied. The transfer matrix method was obtained for both longitudinal and transverse waves by applying the continuity conditions between the consecutive unit cells. Dispersion relations are calculated and plotted for both binary and ternary structures. Also we have investigated the corresponding effects on the band gaps values for the two types of phononic crystals. Furthermore, it can be observed that the complete band gaps are located in the common frequency stop-band regions. Numerical simulations are performed to investigate the effect of different thickness ratios inside each unit cell on the band gap values, as well as unit cells thickness on the central band gap frequency. These phononic band gap materials can be used as a filter for elastic waves at different frequencies values.

  9. A Compact Printed Quadruple Band-Notched UWB Antenna

    Directory of Open Access Journals (Sweden)

    Xiaoyin Li

    2013-01-01

    Full Text Available A novel compact coplanar waveguide- (CPW- fed ultrawideband (UWB printed planar volcano-smoke antenna (PVSA with four band-notches for various wireless applications is proposed and demonstrated. The low-profile antenna consists of a C-shaped parasitic strip to generate a notched band at 8.01~8.55 GHz for the ITU band, two C-shaped slots, and an inverted U-shaped slot etched in the radiator patch to create three notched bands at 5.15~5.35 GHz, 5.75~5.85 GHz, and 7.25~7.75 GHz for filtering the WLAN and X-band satellite signals. Simulated and measured results both confirm that the proposed antenna has a broad bandwidth of 3.1~12 GHz with VSWR < 2 and good omnidirectional radiation patterns with four notched-bands.

  10. Airborne S-Band SAR for Forest Biophysical Retrieval in Temperate Mixed Forests of the UK

    Directory of Open Access Journals (Sweden)

    Ramesh K. Ningthoujam

    2016-07-01

    Full Text Available Radar backscatter from forest canopies is related to forest cover, canopy structure and aboveground biomass (AGB. The S-band frequency (3.1–3.3 GHz lies between the longer L-band (1–2 GHz and the shorter C-band (5–6 GHz and has been insufficiently studied for forest applications due to limited data availability. In anticipation of the British built NovaSAR-S satellite mission, this study evaluates the benefits of polarimetric S-band SAR for forest biophysical properties. To understand the scattering mechanisms in forest canopies at S-band the Michigan Microwave Canopy Scattering (MIMICS-I radiative transfer model was used. S-band backscatter was found to have high sensitivity to the forest canopy characteristics across all polarisations and incidence angles. This sensitivity originates from ground/trunk interaction as the dominant scattering mechanism related to broadleaved species for co-polarised mode and specific incidence angles. The study was carried out in the temperate mixed forest at Savernake Forest and Wytham Woods in southern England, where airborne S-band SAR imagery and field data are available from the recent AirSAR campaign. Field data from the test sites revealed wide ranges of forest parameters, including average canopy height (6–23 m, diameter at breast-height (7–42 cm, basal area (0.2–56 m2/ha, stem density (20–350 trees/ha and woody biomass density (31–520 t/ha. S-band backscatter-biomass relationships suggest increasing backscatter sensitivity to forest AGB with least error between 90.63 and 99.39 t/ha and coefficient of determination (r2 between 0.42 and 0.47 for the co-polarised channel at 0.25 ha resolution. The conclusion is that S-band SAR data such as from NovaSAR-S is suitable for monitoring forest aboveground biomass less than 100 t/ha at 25 m resolution in low to medium incidence angle range.

  11. Usefulness of the inner hypoechoic band of the vermiform appendix as ultrasonographic criteria for the diagnosis of acute appendicitis in children

    International Nuclear Information System (INIS)

    Kim, Bong Soo; Choi, Guk Myung; Kim, Seung Hyoung; Park, Ji Kang; Kim, Kwang Sig; Kang, Hyun Wook; Kang, Ki Soo

    2007-01-01

    We wanted to evaluate the usefulness of the inner hypoechoic band in pediatric appendices as an ultrasonographic criterion to exclude or confirm acute appendicitis. Among the 169 consecutive children with right lower abdominal pain, the 149 appendices depicted on US were prospectively evaluated for an inner hypoechoic band in the appendiceal walls. The sensitivity, specificity, positive and negative predictive values and accuracy were assessed for loss of the inner hypoechoic band as a diagnostic criterion for acute appendicitis. The appendices in 12 (25%) patients with acute appendicitis show entire inner hypoechoic bands and those in 36 patient (75%) did not. The appendices in 97 (96%) patients without acute appendicitis showed entire inner hypoechoic bands, an those in 4 (4%) did not. The loss of inner hypoechoic band confirmed acute appendicitis with a sensitivity of 75%, a specificity of 96%, positive and negative predictive values of 89% and 90%, respectively, and an accuracy of 89%. The thickness of the inner hypoechoic band in patients without appendicitis was significantly higher than that in patients with appendicitis (ρ = 0.03). The visualization of entire thickened inner hypoechoic band in the appendiceal wall helps to rule out acute appendicitis. However, the loss of the inner hypoechoic band is suggestive of acute appendicitis

  12. Usefulness of the inner hypoechoic band of the vermiform appendix as ultrasonographic criteria for the diagnosis of acute appendicitis in children

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Choi, Guk Myung; Kim, Seung Hyoung; Park, Ji Kang; Kim, Kwang Sig; Kang, Hyun Wook; Kang, Ki Soo [Cheju National University College of Medicine, Jeju (Korea, Republic of)

    2007-11-15

    We wanted to evaluate the usefulness of the inner hypoechoic band in pediatric appendices as an ultrasonographic criterion to exclude or confirm acute appendicitis. Among the 169 consecutive children with right lower abdominal pain, the 149 appendices depicted on US were prospectively evaluated for an inner hypoechoic band in the appendiceal walls. The sensitivity, specificity, positive and negative predictive values and accuracy were assessed for loss of the inner hypoechoic band as a diagnostic criterion for acute appendicitis. The appendices in 12 (25%) patients with acute appendicitis show entire inner hypoechoic bands and those in 36 patient (75%) did not. The appendices in 97 (96%) patients without acute appendicitis showed entire inner hypoechoic bands, an those in 4 (4%) did not. The loss of inner hypoechoic band confirmed acute appendicitis with a sensitivity of 75%, a specificity of 96%, positive and negative predictive values of 89% and 90%, respectively, and an accuracy of 89%. The thickness of the inner hypoechoic band in patients without appendicitis was significantly higher than that in patients with appendicitis ({rho} = 0.03). The visualization of entire thickened inner hypoechoic band in the appendiceal wall helps to rule out acute appendicitis. However, the loss of the inner hypoechoic band is suggestive of acute appendicitis.

  13. Banding the World Together; The Global Growth of Control Banding and Qualitative Occupational Risk Management

    OpenAIRE

    Zalk, David M; Heussen, Ga Henri

    2011-01-01

    Control Banding (CB) strategies to prevent work-related illness and injury for 2.5 billion workers without access to health and safety professionals has grown exponentially this last decade. CB originates from the pharmaceutical industry to control active pharmaceutical ingredients without a complete toxicological basis and therefore no occupational exposure limits. CB applications have broadened into chemicals in general - including new emerging risks like nanomaterials and recently into erg...

  14. Validation of S-NPP VIIRS Day-Night Band and M Bands Performance Using Ground Reference Targets of Libya 4 and Dome C

    Science.gov (United States)

    Chen, Xuexia; Wu, Aisheng; Xiong, Xiaoxiong; Lei, Ning; Wang, Zhipeng; Chiang, Kwofu

    2015-01-01

    This paper provides methodologies developed and implemented by the NASA VIIRS Calibration Support Team (VCST) to validate the S-NPP VIIRS Day-Night band (DNB) and M bands calibration performance. The Sensor Data Records produced by the Interface Data Processing Segment (IDPS) and NASA Land Product Evaluation and Algorithm Testing Element (PEATE) are acquired nearly nadir overpass for Libya 4 desert and Dome C snow surfaces. In the past 3.5 years, the modulated relative spectral responses (RSR) change with time and lead to 3.8% increase on the DNB sensed solar irradiance and 0.1% or less increases on the M4-M7 bands. After excluding data before April 5th, 2013, IDPS DNB radiance and reflectance data are consistent with Land PEATE data with 0.6% or less difference for Libya 4 site and 2% or less difference for Dome C site. These difference are caused by inconsistent LUTs and algorithms used in calibration. In Libya 4 site, the SCIAMACHY spectral and modulated RSR derived top of atmosphere (TOA) reflectance are compared with Land PEATE TOA reflectance and they indicate a decrease of 1.2% and 1.3%, respectively. The radiance of Land PEATE DNB are compared with the simulated radiance from aggregated M bands (M4, M5, and M7). These data trends match well with 2% or less difference for Libya 4 site and 4% or less difference for Dome C. This study demonstrate the consistent quality of DNB and M bands calibration for Land PEATE products during operational period and for IDPS products after April 5th, 2013.

  15. Dialysis shunt-associated steal syndrome (DASS) following brachial accesses: the value of fistula banding under blood flow control.

    Science.gov (United States)

    Thermann, Florian; Ukkat, Jörg; Wollert, Ulrich; Dralle, Henning; Brauckhoff, Michael

    2007-11-01

    Dialysis shunt-associated steal syndrome (DASS) is a rare complication of hemodialysis access (HA) which preferably occurs in brachial fistulas. Treatment options are discussed controversially. Aim of this study was to evaluate flow-controlled fistula banding. Patients treated between 2002 and 2006 were included in this prospective survey. According to a classification we established, patients were typed DASS I-III (I: short history, no dermal lesions; II: long history, skin lesions; III: long history, gangrene). Surgical therapy was HA banding including controlled reduction (about 50% of initial flow) of HA blood flow (patients type I and II). Patients with type III underwent closure of the HA. In 15 patients with relevant DASS, blood-flow-controlled banding was performed. In ten patients (all type I), banding led to restitution of the hand function while preserving the HA. In five patients (all type II), banding was not successful; in two patients, closure of the HA was performed eventually. In five patients (type III), primary closure of the HA was performed. Four patients with DASS type II but only two with DASS type I had diabetes mellitus (p = 0.006). Banding under blood flow control resulting in an approximately 50% reduction in the initial blood flow is an adequate therapeutic option in patients with brachial HA and type I-DASS. In type II-DASS, banding does not lead to satisfying results, more complex surgical options might be more successful. Diabetes is associated with poor HA outcome in case of DASS.

  16. Prenatal imaging of amniotic band sequence: utility and role of fetal MRI as an adjunct to prenatal US

    International Nuclear Information System (INIS)

    Neuman, Jeremy; Calvo-Garcia, Maria A.; Kline-Fath, Beth M.; Bitters, Constance; Merrow, Arnold C.; Guimaraes, Carolina V.A.; Lim, Foong-Yen

    2012-01-01

    Amniotic band sequence and its US manifestations have been well-described. There is little information, however, regarding the accuracy and utility of fetal MRI. To describe the MRI findings in amniotic band sequence and to compare the diagnostic accuracy of MRI and US. Prenatal MRI and US studies were retrospectively reviewed in 14 consecutive pregnancies with confirmed amniotic band sequence. Both studies were evaluated for amniotic band visualization, body part affected, type of deformity, umbilical cord involvement and vascular abnormality. Amniotic bands were confidently identified with MRI in 8 fetuses (57%), suggested with MRI in 3 fetuses (21%) and confidently seen by US in 13 fetuses (93%). Neither modality detected surgically proven bands on one fetus. Both techniques were equally able to define the body part affected and the type of deformity. At least one limb abnormality was visualized in all cases and truncal involvement was present in two cases. Cord involvement was identified in seven cases, with one case detected only by MRI. Fetal MRI is able to visualize amniotic bands and their secondary manifestations and could be complementary to prenatal US when fetal surgery is contemplated. (orig.)

  17. Panchromatic cooperative hyperspectral adaptive wide band deletion repair method

    Science.gov (United States)

    Jiang, Bitao; Shi, Chunyu

    2018-02-01

    In the hyperspectral data, the phenomenon of stripe deletion often occurs, which seriously affects the efficiency and accuracy of data analysis and application. Narrow band deletion can be directly repaired by interpolation, and this method is not ideal for wide band deletion repair. In this paper, an adaptive spectral wide band missing restoration method based on panchromatic information is proposed, and the effectiveness of the algorithm is verified by experiments.

  18. Observations of banding in first-year Arctic sea ice

    Science.gov (United States)

    Cole, David M.; Eicken, Hajo; Frey, Karoline; Shapiro, Lewis H.

    2004-08-01

    Horizontal banding features, alternating dark and bright horizontal bands apparent in ice cores and stratigraphic cross sections have long been observed in first-year sea ice and are frequently associated with bands of high and low brine or gas porosity. Observations on the land-fast ice near Barrow, Alaska, in recent years have revealed particularly striking banding patterns and prompted a study of their macroscopic and microscopic characteristics. The banding patterns are quantified from photographs of full-depth sections of the ice, and examples are presented from the Chukchi Sea and Elson Lagoon. Statistics on band spacing are presented, and the growth records for three seasons are employed to estimate their time of formation. These data provide insight into the periodicity of the underlying phenomena. Micrographs are used to examine the microstructural variations associated with various banding features and to quantify the geometry of the constituent brine inclusions associated with high- and low-porosity bands. The micrography revealed that the area fraction of brine inclusions varied by a factor of nearly 3 through the more pronounced high- and low-porosity bands. Vertical micrographs obtained shortly after the materials' removal from the ice sheet showed that significantly larger inclusions form abruptly at the start of the high-porosity bands and frequently terminate abruptly at the end of the band. Crystallographic observations indicated that the high-porosity bands supported the nucleation and growth of crystals having substantially different orientations from the very well aligned columnar structure that characterized the bulk of the sheet.

  19. Surface Resonance Bands on (001)W: Experimental Dispersion Relations

    DEFF Research Database (Denmark)

    Willis, R. F.; Feuerbacher, B.; Christensen, N. Egede

    1977-01-01

    A band of unbound surface states (resonances), located in an energy region above the vacuum threshold corresponding to an energy band gap in the electron states of the bulk crystal, has been observed by angle-resolved secondary-electron-emission spectroscopy. The experimental dispersion behavior...... is in agreement with the two-dimensional band structure of a clean (001)W surface recently proposed by Smith and Mittheiss....

  20. Identical gamma-vibrational bands in {sup 165}Ho

    Energy Technology Data Exchange (ETDEWEB)

    Radford, D.C.; Galindo-Uribarri, A.; Janzen, V.P. [Chalk River Labs., Ontario (Canada)] [and others

    1996-12-31

    The structure of {sup 165}Ho at moderate spins has been investigated by means of Coulomb excitation. Two {gamma}-vibrational bands (K{sup {pi}} = 11/2{sup {minus}} and K{sup {pi}} = 3/2{sup {minus}}) are observed, with very nearly identical in-band {gamma}-ray energies. Gamma-ray branching ratios are analyzed to extract information on Coriolis mixing, and the role of the K quantum number in identical bands is discussed.

  1. Micromachined millimeter-wave photonic band-gap crystals

    International Nuclear Information System (INIS)

    Oezbay, E.; Michel, E.; Tuttle, G.; Biswas, R.; Sigalas, M.; Ho, K.

    1994-01-01

    We have developed a new technique for fabricating three-dimensional photonic band-gap crystals. Our method utilizes an orderly stacking of micromachined (110) silicon wafers to build the periodic structure. A structure with a full three-dimensional photonic band gap centered near 100 GHz was measured, with experimental results in good agreement with theoretical predictions. This basic approach described should be extendable to build structures with photonic band-gap frequencies ranging from 30 GHz to 3 THz

  2. X-band RF power sources for accelerator applications

    International Nuclear Information System (INIS)

    Kirshner, Mark F.; Kowalczyk, Richard D.; Wilsen, Craig B.; True, Richard B.; Simpson, Ian T.; Wray, John T.

    2011-01-01

    The majority of medical and industrial linear accelerators (LINACs) in use today operate at S-band. To reduce size and weight, these systems are gradually migrating toward X-band. The new LINACs will require suitable RF components to power them. In anticipation of this market, L-3 Communications Electron Devices Division (EDD) has recently developed a suite of RF sources operating at 9.3 GHz to complement our existing S-band product line. (author)

  3. Gastropericardial Fistula as a Late Complication of Laparoscopic Gastric Banding

    Directory of Open Access Journals (Sweden)

    Adam A Rudd

    2017-01-01

    Full Text Available Laparoscopic adjustable gastric banding (LAGB is a bariatric procedure that is being performed with increasing frequency as an alternative management option for morbid obesity. Several common complications have been reported including gastric band slippage and associated pouch dilatation, intragastric erosion of the band, gastric wall perforation, and abscess formation. We present a case of gastropericardial fistula occurring nine years after an LAGB. There have been no previous documented cases of the complication after this procedure.

  4. Left regular bands of groups of left quotients

    International Nuclear Information System (INIS)

    El-Qallali, A.

    1988-10-01

    A semigroup S which has a left regular band of groups as a semigroup of left quotients is shown to be the semigroup which is a left regular band of right reversible cancellative semigroups. An alternative characterization is provided by using spinned products. These results are applied to the case where S is a superabundant whose set of idempotents forms a left normal band. (author). 13 refs

  5. Deep-Space Ka-Band Flight Experience

    Science.gov (United States)

    Morabito, D. D.

    2017-11-01

    Lower frequency bands have become more congested in allocated bandwidth as there is increased competition between flight projects and other entities. Going to higher frequency bands offers significantly more bandwidth, allowing for the use of much higher data rates. However, Ka-band is more susceptible to weather effects than lower frequency bands currently used for most standard downlink telemetry operations. Future or prospective flight projects considering deep-space Ka-band (32-GHz) telemetry data links have expressed an interest in understanding past flight experience with received Ka-band downlink performance. Especially important to these flight projects is gaining a better understanding of weather effects from the experience of current or past missions that operated Ka-band radio systems. We will discuss the historical flight experience of several Ka-band missions starting from Mars Observer in 1993 up to present-day deep-space missions such as Kepler. The study of historical Ka-band flight experience allows one to recommend margin policy for future missions. Of particular interest, we will review previously reported-on flight experience with the Cassini spacecraft Ka-band radio system that has been used for radio science investigations as well as engineering studies from 2004 to 2015, when Cassini was in orbit around the planet Saturn. In this article, we will focus primarily on the Kepler spacecraft Ka-band link, which has been used for operational telemetry downlink from an Earth trailing orbit where the spacecraft resides. We analyzed the received Ka-band signal level data in order to characterize link performance over a wide range of weather conditions and as a function of elevation angle. Based on this analysis of Kepler and Cassini flight data, we found that a 4-dB margin with respect to adverse conditions ensures that we achieve at least a 95 percent data return.

  6. Analytically derived conversion of spectral band radiance to brightness temperature

    Energy Technology Data Exchange (ETDEWEB)

    Berk, Alexander [Spectral Sciences, Inc., 44th Avenue, Burlington, MA 01803 (United States)], E-mail: lex@spectral.com

    2008-05-15

    Simple analytic expressions for brightness temperature have been derived in terms of band response function spectral moments. Accuracy measures are also derived. Application of these formulas to GOES-12 Sounder thermal infrared bands produces brightness temperature residuals between -5.0 and 2.5 mK for a 150-400 K temperature range. The magnitude of residuals for the five ASTER Radiometer thermal infrared bands over the same temperature range is less than 0.22 mK.

  7. Gastric band tubing-related complication during pregnancy.

    Science.gov (United States)

    Ongso, Yuni F; Beh, Han N

    2017-11-01

    In the past few decades, laparoscopic adjustable gastric banding is one of the most common bariatric procedures performed to treat morbid obesity. Device-related complication such as connection-tubing problem is rare. Here we present a case of gastric band tubing complication during pregnancy. This case illustrates the need to maintain high index of suspicion of gastric band device-related complication during pregnancy and early referral for bariatric surgical assessment is recommended.

  8. Development of a Control Banding Tool for Nanomaterials

    OpenAIRE

    Riediker, M.; Ostiguy, C.; Triolet, J.; Troisfontaine, P.; Vernez, D.; Bourdel, G.; Thieriet, N.; Cadène, A.

    2012-01-01

    Control banding (CB) can be a useful tool for managing the potential risks of nanomaterials. The here proposed CB, which should be part of an overall risk control strategy, groups materials by hazard and emission potential. The resulting decision matrix proposes control bands adapted to the risk potential levels and helps define an action plan. If this plan is not practical and financially feasible, a full risk assessment is launched. The hazard banding combines key concepts of nanomaterial t...

  9. The Marvels of Electromagnetic Band Gap (EBG) Structures

    Science.gov (United States)

    2003-11-01

    terminology of "Electromagnetic conference papers and journal articles dealing with Band- gaps (EBG)". Recently, many researchers the characterizations...Band Gap (EBG) Structures 9 utilized to reduce the mutual coupling between Structures: An FDTD/Prony Technique elements of antenna arrays. based on the...Band- Gap of several patents. He has had pioneering research contributions in diverse areas of electromagnetics,Snteructure", Dymposiget o l 21 IE 48

  10. Design of an S band narrow-band bandpass BAW filter

    Science.gov (United States)

    Gao, Yang; Zhao, Kun-li; Han, Chao

    2017-11-01

    An S band narrowband bandpass filter BAW with center frequency 2.460 GHz, bandwidth 41MHz, band insertion loss - 1.154 dB, the passband ripple 0.9 dB, the out of band rejection about -42.5dB@2.385 GHz; -45.5dB@2.506 GHz was designed for potential UAV measurement and control applications. According to the design specifications, the design is as follows: each FBAR's stack was designed in BAW filter by using Mason model. Each FBAR's shape was designed with the method of apodization electrode. The layout of BAW filter was designed. The acoustic-electromagnetic cosimulation model was built to validate the performance of the designed BAW filter. The presented design procedure is a common one, and there are two characteristics: 1) an A and EM co-simulation method is used for the final BAW filter performance validation in the design stage, thus ensures over-optimistic designs by the bare 1D Mason model are found and rejected in time; 2) An in-house developed auto-layout method is used to get compact BAW filter layout, which simplifies iterative error-and-try work here and output necessary in-plane geometry information to the A and EM cosimulation model.

  11. S-band and X-band integrated PWT photoelectron linacs

    International Nuclear Information System (INIS)

    Yu, D.; Newsham, D.; Zeng, J.; Rosenzweig, J.

    2001-01-01

    A compact high-energy injector, which has been developed by DULY Research Inc., will have wide scientific, industrial, and medical applications. The new photoelectron injector integrates the photocathode directly into a multicell linear accelerator. By focusing the beam with solenoids or permanent magnets, and producing high current with low emittance, high brightness and low energy spread are achieved. In addition to providing a small footprint and improved beam quality in an integrated structure, the compact system considerably simplifies external subsystems required to operate the photoelectron linac, including rf power transport, beam focusing, vacuum and cooling. The photoelectron linac employs an innovative Plane-Wave-Transformer (PWT) design, which provides strong cell-to-cell coupling, relaxes manufacturing tolerances and facilitates the attachment of external ports to the compact structure with minimal field interference. DULY Research Inc. under the support of the DOE Small Business Innovation Research (SBIR) program, has developed, constructed and installed a 20-MeV, S-band compact electron source at UCLA. Cold test results for this device are presented. DULY Research is also actively engaged in the development of an X-band photoelectron linear accelerator in a SBIR project. When completed, the higher frequency structure will be approximately three times smaller. Design considerations for this device are discussed following the S-band cold test results

  12. Throughput Measurement of a Dual-Band MIMO Rectangular Dielectric Resonator Antenna for LTE Applications.

    Science.gov (United States)

    Nasir, Jamal; Jamaluddin, Mohd Haizal; Ahmad Khan, Aftab; Kamarudin, Muhammad Ramlee; Yen, Bruce Leow Chee; Owais, Owais

    2017-01-13

    An L-shaped dual-band multiple-input multiple-output (MIMO) rectangular dielectric resonator antenna (RDRA) for long term evolution (LTE) applications is proposed. The presented antenna can transmit and receive information independently using fundamental TE 111 and higher order TE 121 modes of the DRA. TE 111 degenerate mode covers LTE band 2 (1.85-1.99 GHz), 3 (1.71-1.88 GHz), and 9 (1.7499-1.7849 GHz) at f r = 1.8 GHz whereas TE 121 covers LTE band 7 (2.5-2.69 GHz) at f r = 2.6 GHz, respectively. An efficient design method has been used to reduce mutual coupling between ports by changing the effective permittivity values of DRA by introducing a cylindrical air-gap at an optimal position in the dielectric resonator. This air-gap along with matching strips at the corners of the dielectric resonator keeps the isolation at a value more than 17 dB at both the bands. The diversity performance has also been evaluated by calculating the envelope correlation coefficient, diversity gain, and mean effective gain of the proposed design. MIMO performance has been evaluated by measuring the throughput of the proposed MIMO antenna. Experimental results successfully validate the presented design methodology in this work.

  13. E- and W-band high-capacity hybrid fiber-wireless link

    DEFF Research Database (Denmark)

    Vegas Olmos, Juan José; Pang, Xiaodan; Tafur Monroy, Idelfonso

    2014-01-01

    In this paper we summarize the work conducted in our group in the area of E- and W-band optical high-capacity fiber-wireless links. We present performance evaluations of E- and W-band mm-wave signal generation using photonic frequency upconversion employing both VCSELs and ECLs, along with transm...... in mobile backhaul/fronthaul applications, dense distributed antenna systems and fiber-over-radio scenarios.......In this paper we summarize the work conducted in our group in the area of E- and W-band optical high-capacity fiber-wireless links. We present performance evaluations of E- and W-band mm-wave signal generation using photonic frequency upconversion employing both VCSELs and ECLs, along...... with transmission over different type of optical fibers and for a number of values for the wireless link distance. Hybrid wireless-optical links can be composed of mature and resilient technology available off-the-shelf, and provide functionalities that can add value to optical access networks, specifically...

  14. Real-time dual-band haptic music player for mobile devices.

    Science.gov (United States)

    Hwang, Inwook; Lee, Hyeseon; Choi, Seungmoon

    2013-01-01

    We introduce a novel dual-band haptic music player for real-time simultaneous vibrotactile playback with music in mobile devices. Our haptic music player features a new miniature dual-mode actuator that can produce vibrations consisting of two principal frequencies and a real-time vibration generation algorithm that can extract vibration commands from a music file for dual-band playback (bass and treble). The algorithm uses a "haptic equalizer" and provides plausible sound-to-touch modality conversion based on human perceptual data. In addition, we present a user study carried out to evaluate the subjective performance (precision, harmony, fun, and preference) of the haptic music player, in comparison with the current practice of bass-band-only vibrotactile playback via a single-frequency voice-coil actuator. The evaluation results indicated that the new dual-band playback outperforms the bass-only rendering, also providing several insights for further improvements. The developed system and experimental findings have implications for improving the multimedia experience with mobile devices.

  15. Surface correlation effects in two-band strongly correlated slabs.

    Science.gov (United States)

    Esfahani, D Nasr; Covaci, L; Peeters, F M

    2014-02-19

    Using an extension of the Gutzwiller approximation for an inhomogeneous system, we study the two-band Hubbard model with unequal band widths for a slab geometry. The aim is to investigate the mutual effect of individual bands on the spatial distribution of quasi-particle weight and charge density, especially near the surface of the slab. The main effect of the difference in band width is the presence of two different length scales corresponding to the quasi-particle profile of each band. This is enhanced in the vicinity of the critical interaction of the narrow band where an orbitally selective Mott transition occurs and a surface dead layer forms for the narrow band. For the doped case, two different regimes of charge transfer between the surface and the bulk of the slab are revealed. The charge transfer from surface/center to center/surface depends on both the doping level and the average relative charge accumulated in each band. Such effects could also be of importance when describing the accumulation of charges at the interface between structures made of multi-band strongly correlated materials.

  16. Workshop: Western hemisphere network of bird banding programs

    Science.gov (United States)

    Celis-Murillo, A.

    2007-01-01

    Purpose: To promote collaboration among banding programs in the Americas. Introduction: Bird banding and marking provide indispensable tools for ornithological research, management, and conservation of migratory birds on migratory routes, breeding and non-breeding grounds. Many countries and organizations in Latin America and the Caribbean are in the process of developing or have expressed interest in developing national banding schemes and databases to support their research and management programs. Coordination of developing and existing banding programs is essential for effective data management, reporting, archiving and security, and most importantly, for gaining a fuller understanding of migratory bird conservation issues and how the banding data can help. Currently, there is a well established bird-banding program in the U.S.A. and Canada, and programs in other countries are being developed as well. Ornithologists in many Latin American countries and the Caribbean are interested in using banding and marking in their research programs. Many in the ornithological community are interested in establishing banding schemes and some countries have recently initiated independent banding programs. With the number of long term collaborative and international initiatives increasing, the time is ripe to discuss and explore opportunities for international collaboration, coordination, and administration of bird banding programs in the Western Hemisphere. We propose the second ?Western Hemisphere Network of Bird Banding Programs? workshop, in association with the SCSCB, to be an essential step in the progress to strengthen international partnerships and support migratory bird conservation in the Americas and beyond. This will be the second multi-national meeting to promote collaboration among banding programs in the Americas (the first meeting was held in October 8-9, 2006 in La Mancha, Veracruz, Mexico). The Second ?Western Hemisphere Network of Bird Banding Programs

  17. A programmable ultra-low noise X-band exciter.

    Science.gov (United States)

    MacMullen, A; Hoover, L R; Justice, R D; Callahan, B S

    2001-07-01

    A programmable ultra-low noise X-band exciter has been developed using commercial off-the-shelf components. Its phase noise is more than 10 dB below the best available microwave synthesizers. It covers a 7% frequency band with 0.1-Hz resolution. The X-band output at +23 dBm is a combination of signals from an X-band sapphire-loaded cavity oscillator (SLCO), a low noise UHF frequency synthesizer, and special-purpose frequency translation and up-conversion circuitry.

  18. Block 3 X-band receiver-exciter

    Science.gov (United States)

    Johns, C. E.

    1987-01-01

    The development of an X-band exciter, for use in the X-Band Uplink Subsystem, was completed. The exciter generates the drive signal for the X-band transmitter and also generates coherent test signals for the S- and X-band Block 3 translator and a Doppler reference signal for the Doppler extractor system. In addition to the above, the exciter generates other reference signals that are described. Also presented is an overview of the exciter design and some test data taken on the prototype. A brief discussion of the Block 3 Doppler extractor is presented.

  19. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  20. Injuries and Injury Prevention in the US Army Band

    National Research Council Canada - National Science Library

    Knapik, Joseph J; Jones, Sarah B; Ohlin, Doug W; Canham-Chervak, Michelle; Darakjy, Salima S; Goddard, Donald E; Hauret, Keith G; Hadley, Jeffrey A; Twombly, Gregory; Harkins, Deanna K

    2006-01-01

    ...) medical data from the Defense Medical Surveillance System, 3) audiograms of Band member from the Defense Occupational and Environmental Health Readiness System-Hearing Conservation database, 4...

  1. Conservation of topological quantum numbers in energy bands

    International Nuclear Information System (INIS)

    Chang, L.N.; Liang, Y.

    1988-01-01

    Quantum systems described by parametrized Hamiltinians are studied in a general context. Within this context, the classification scheme of Avron-Seiler-Simon for non-degenerate energy bands is extended to cover general parameter spaces, whole their sum rule is generalized to cover cases with degenerate bands as well. Additive topological quantum numbers are defined, and these are shown to be conserved in energy band ''collisions''. The conservation laws dictate that when some invariants are non-vanishing, no energy gap can develop in a set of degenerate bands. This gives rise to a series of splitting rules

  2. The amniotic band syndrome: antenatal sonographic diagnosis and potential pitfalls.

    Science.gov (United States)

    Mahony, B S; Filly, R A; Callen, P W; Golbus, M S

    1985-05-01

    Amniotic band syndrome causes a variety of fetal malformations involving the limbs, craniofacial region, and trunk. Six prenatally diagnosed cases of amniotic band syndrome are discussed. The diagnosis was based on sonographic visualization of either amniotic sheets or bands associated with fetal deformation or deformities in nonembryologic distributions known to characterize the amniotic band syndrome. Seven additional cases are considered in which an aberrant sheet of tissue with a free edge was visualized within the amniotic cavity but no restriction of fetal motion or subsequent deformity was demonstrated.

  3. Band structures in the nematic elastomers phononic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuai [Department of Mechanics, School of Civil Engineering, Beijing Jiaotong University, Beijing 100044 (China); School of Civil Engineering and Architecture, Anyang Normal University, Anyang 455000 (China); Liu, Ying, E-mail: yliu5@bjtu.edu.cn [Department of Mechanics, School of Civil Engineering, Beijing Jiaotong University, Beijing 100044 (China); Liang, Tianshu [Department of Mechanics, School of Civil Engineering, Beijing Jiaotong University, Beijing 100044 (China)

    2017-02-01

    As one kind of new intelligent materials, nematic elastomers (NEs) represent an exciting physical system that combines the local orientational symmetry breaking and the entropic rubber elasticity, producing a number of unique physical phenomena. In this paper, the potential application of NEs in the band tuning is explored. The band structures in two kinds of NE phononic crystals (PCs) are investigated. Through changing NE intrinsic parameters, the influence of the porosity, director rotation and relaxation on the band structures in NE PCs are analyzed. This work is a meaningful try for application of NEs in acoustic field and proposes a new intelligent strategy in band turning.

  4. Band structures in the nematic elastomers phononic crystals

    International Nuclear Information System (INIS)

    Yang, Shuai; Liu, Ying; Liang, Tianshu

    2017-01-01

    As one kind of new intelligent materials, nematic elastomers (NEs) represent an exciting physical system that combines the local orientational symmetry breaking and the entropic rubber elasticity, producing a number of unique physical phenomena. In this paper, the potential application of NEs in the band tuning is explored. The band structures in two kinds of NE phononic crystals (PCs) are investigated. Through changing NE intrinsic parameters, the influence of the porosity, director rotation and relaxation on the band structures in NE PCs are analyzed. This work is a meaningful try for application of NEs in acoustic field and proposes a new intelligent strategy in band turning.

  5. Electronic band structure of lithium, sodium and potassium fluorides

    International Nuclear Information System (INIS)

    Jouanin, C.; Albert, J.P.; Gout, C.

    1975-01-01

    A mixed tight-binding, pseudopotential method is proposed to calculate the energy band structure of large-gap crystals and is tested here on LiF, NaF and KF. Three-centre terms are included in the determination of the valence bands by the tight-binding method and for the conduction bands we use a pseudopotential model proposed by Bassani and Giuliano, modified for the positive ions. By taking into account the polarization corrections, transitions calculated from the energy band structures are compared with experimental data and the agreement is generally good

  6. Multiple superdeformed bands in Sr, Y, and Zr nuclei

    International Nuclear Information System (INIS)

    Reviol, W.; Sarantites, D.G.; Lerma, F.; Devlin, M.; LaFosse, D.R.; Chiara, C.J.; Wyss, R.; Baktash, C.; Jin, H.-Q.; Tabor, S.L.; Soltysik, D.; Clark, R.M.; Lee, I.Y.; Macchiavelli, A.O.; MacLeod, R.W.

    2003-01-01

    Multiple superdeformed bands in the nuclei 80-83Sr, 82-84Y, and 83,84Zr have been studied in a backed-target experiment using the Gammasphere and Microball detector arrays. For 15 bands in these nuclei, average transition quadrupole moments (Qt) have been measured accurately. Among those are two pairs of 'isospectral' bands and the Qt values obtained in each case are nearly identical. The measured Qt values and dynamical moments of inertia place stringent conditions on configuration assignments for the bands obtained from mean field calculations

  7. The complex band structure for armchair graphene nanoribbons

    International Nuclear Information System (INIS)

    Zhang Liu-Jun; Xia Tong-Sheng

    2010-01-01

    Using a tight binding transfer matrix method, we calculate the complex band structure of armchair graphene nanoribbons. The real part of the complex band structure calculated by the transfer matrix method fits well with the bulk band structure calculated by a Hermitian matrix. The complex band structure gives extra information on carrier's decay behaviour. The imaginary loop connects the conduction and valence band, and can profoundly affect the characteristics of nanoscale electronic device made with graphene nanoribbons. In this work, the complex band structure calculation includes not only the first nearest neighbour interaction, but also the effects of edge bond relaxation and the third nearest neighbour interaction. The band gap is classified into three classes. Due to the edge bond relaxation and the third nearest neighbour interaction term, it opens a band gap for N = 3M − 1. The band gap is almost unchanged for N = 3M + 1, but decreased for N = 3M. The maximum imaginary wave vector length provides additional information about the electrical characteristics of graphene nanoribbons, and is also classified into three classes

  8. Photodensitometric tracing of Mach bands and its significance

    International Nuclear Information System (INIS)

    Yoo, Shi Joon; Cho, Kyung Sik; Kang, Heung Sik; Cho, Byung Jae

    1984-01-01

    Mach bands, a visual phenomenon resulting from lateral inhibitory impulses in the retina, are recognized as lucent or dense lines at the borders of different radiographic densities. A number of clinical situations have been described in which Mach bands may cause difficulty in radiographic diagnosis. Photodensitometric measurement of the film can differentiate the true change in film density from the Mach band which is an optical illusion. Authors present several examples of photodensitometric tracings of Mach bands, with the brief review of the mechanism of their production

  9. Picosecond thermometer in the amide I band of myoglobin

    DEFF Research Database (Denmark)

    Austin, R.H.; Xie, A.; Meer, L. van der

    2005-01-01

    The amide I and II bands in myoglobin show a heterogeneous temperature dependence, with bands at 6.17 and 6.43 mu m which are more intense at low temperatures. The amide I band temperature dependence is on the long wavelength edge of the band, while the short wavelength side has almost...... can be used to determine the time it takes vibrational energy to flow into the hydration shell. We determine that vibrational energy flow to the hydration shell from the amide I takes approximately 20 ps to occur....

  10. Macroscopic optical response and photonic bands

    International Nuclear Information System (INIS)

    Pérez-Huerta, J S; Luis Mochán, W; Ortiz, Guillermo P; Mendoza, Bernardo S

    2013-01-01

    We develop a formalism for the calculation of the macroscopic dielectric response of composite systems made of particles of one material embedded periodically within a matrix of another material, each of which is characterized by a well-defined dielectric function. The nature of these dielectric functions is arbitrary, and could correspond to dielectric or conducting, transparent or opaque, absorptive and dispersive materials. The geometry of the particles and the Bravais lattice of the composite are also arbitrary. Our formalism goes beyond the long-wavelength approximation as it fully incorporates retardation effects. We test our formalism through the study of the propagation of electromagnetic waves in two-dimensional photonic crystals made of periodic arrays of cylindrical holes in a dispersionless dielectric host. Our macroscopic theory yields a spatially dispersive macroscopic response which allows the calculation of the full photonic band structure of the system, as well as the characterization of its normal modes, upon substitution into the macroscopic field equations. We can also account approximately for the spatial dispersion through a local magnetic permeability and analyze the resulting dispersion relation, obtaining a region of left handedness. (paper)

  11. Metallic photonic band-gap materials

    International Nuclear Information System (INIS)

    Sigalas, M.M.; Chan, C.T.; Ho, K.M.; Soukoulis, C.M.

    1995-01-01

    We calculate the transmission and absorption of electromagnetic waves propagating in two-dimensional (2D) and 3D periodic metallic photonic band-gap (PBG) structures. For 2D systems, there is substantial difference between the s- and p-polarized waves. The p-polarized waves exhibit behavior similar to the dielectric PBG's. But, the s-polarized waves have a cutoff frequency below which there are no propagating modes. For 3D systems, the results are qualitatively the same for both polarizations but there are important differences related to the topology of the structure. For 3D structures with isolated metallic scatterers (cermet topology), the behavior is similar to that of the dielectric PBG's, while for 3D structures with the metal forming a continuous network (network topology), there is a cutoff frequency below which there are no propagating modes. The systems with the network topology may have some interesting applications for frequencies less than about 1 THz where the absorption can be neglected. We also study the role of the defects in the metallic structures

  12. Severe neurological complication following adjustable gastric banding.

    Science.gov (United States)

    Martines, G; Musa, N; Aquilino, F; Capuano, P

    2018-01-01

    In the last years with the increase of bariatric surgery, first of all as a result of new indications, a rise in the incidence of nutrient-related complications has been observed. Currently little is known about the impact of post-bariatric malnutrition and neurological complications. Wernicke's encephalopathy is a severe neurological syndrome which occurs as a result of thiamine deficiency. Wernicke-Korsakoff syndrome must be considered a serious neurological complication of bariatric surgery with significant morbidity and mortality, with rapidly progressing neurological symptoms, and must be treated immediately. We report the case of a 35 years-old male patient, affected by morbid obesity, anxious-depressive syndrome and alcohol use disorder, who after adjustable gastric banding implanted in another hospital developed a severe malnutrition and neurological syndrome. The patient showed poor adherence to the follow-up and to the dietary indications and after all, we needed to place a PEG for enteral nutrition in order to resolve the malnutrition condition and the neurological syndrome. Our experience emphasizes that preoperative selection and assessment of a patient's nutritional status according to guidelines, is required to identify potential problems, and that bariatric surgeons or physicians caring for patient who have undergone bariatric surgery should be familiar with the constellation of nutritional and neurological disorder that may occur after surgery. We want to remark the importance of preoperative selection of the patients, the follow-up and the cooperation between patient and physician in order to obtain the best result and avoid severe complications.

  13. MR findings in iliotibial band syndrome

    International Nuclear Information System (INIS)

    Nishimura, G.; Yamato, M.; Tamai, K.; Takahashi, J.; Uetani, M.

    1997-01-01

    Objective. To elucidate the MR findings in iliotibial band (ITB) syndrome. Design and patients. The subjects comprised four patients (five knees) with lateral knee pain: two athletes and two non-athletes. One non-athlete was engaged in work requiring repetitive knee movement, and the other suffered from Cushing syndrome and had bilateral abnormalities. All patients were suspected of having a lateral meniscal tear prior to MR examination, but physical examination following provisional MR diagnosis warranted the final diagnosis. MR studies included fast spin echo sagittal imaging, fat-saturated fast spin echo proton density coronal imaging, and T2* radial imaging. Twelve normal volunteers were examined. Results and conclusion. Fat-saturated coronal imaging demonstrated an ill-defined, high-intensity area deep to the ITB. T2* radial imaging showed an identical, but less conspicuous, abnormality. The MR finding suggested soft tissue inflammation and/or edema rather than focal fluid collection in the bursae. The signal alteration predominated in the region beneath the posterior fibers of the ITB, thus supporting the current opinion that the posterior fibers of the ITB are tighter against the lateral femoral epicondyle than the anterior fibers. The ITB itself did not show any signal alteration or increased thickness. (orig.). With 4 figs., 1 tab

  14. Topological nanophononic states by band inversion

    Science.gov (United States)

    Esmann, Martin; Lamberti, Fabrice Roland; Senellart, Pascale; Favero, Ivan; Krebs, Olivier; Lanco, Loïc; Gomez Carbonell, Carmen; Lemaître, Aristide; Lanzillotti-Kimura, Norberto Daniel

    2018-04-01

    Nanophononics is essential for the engineering of thermal transport in nanostructured electronic devices, it greatly facilitates the manipulation of mechanical resonators in the quantum regime, and it could unveil a new route in quantum communications using phonons as carriers of information. Acoustic phonons also constitute a versatile platform for the study of fundamental wave dynamics, including Bloch oscillations, Wannier-Stark ladders, and other localization phenomena. Many of the phenomena studied in nanophononics were inspired by their counterparts in optics and electronics. In these fields, the consideration of topological invariants to control wave dynamics has already had a great impact for the generation of robust confined states. Interestingly, the use of topological phases to engineer nanophononic devices remains an unexplored and promising field. Conversely, the use of acoustic phonons could constitute a rich platform to study topological states. Here, we introduce the concept of topological invariants to nanophononics and experimentally implement a nanophononic system supporting a robust topological interface state at 350 GHz. The state is constructed through band inversion, i.e., by concatenating two semiconductor superlattices with inverted spatial mode symmetries. The existence of this state is purely determined by the Zak phases of the constituent superlattices, i.e., the one-dimensional Berry phase. We experimentally evidenced the mode through Raman spectroscopy. The reported robust topological interface states could become part of nanophononic devices requiring resonant structures such as sensors or phonon lasers.

  15. Annual Growth Bands in Hymenaea courbaril

    Energy Technology Data Exchange (ETDEWEB)

    Westbrook, J A; Guilderson, T P; Colinvaux, P A

    2004-02-09

    One significant source of annual temperature and precipitation data arises from the regular annual secondary growth rings of trees. Several tropical tree species are observed to form regular growth bands that may or may not form annually. Such growth was observed in one stem disk of the tropical legume Hymenaea courbaril near the area of David, Panama. In comparison to annual reference {Delta}{sup 14}C values from wood and air, the {Delta}{sup 14}C values from the secondary growth rings formed by H. courbaril were determined to be annual in nature in this one stem disk specimen. During this study, H. courbaril was also observed to translocate recently produced photosynthate into older growth rings as sapwood is converted to heartwood. This process alters the overall {Delta}{sup 14}C values of these transitional growth rings as cellulose with a higher {Delta}{sup 14}C content is translocated into growth rings with a relatively lower {Delta}{sup 14}C content. Once the annual nature of these growth rings is established, further stable isotope analyses on H. courbaril material in other studies may help to complete gaps in the understanding of short and of long term global climate patterns.

  16. Electronic Band Structure of Helical Polyisocyanides.

    Science.gov (United States)

    Champagne, Benoît; Liégeois, Vincent; Fripiat, Joseph G; Harris, Frank E

    2017-10-19

    Restricted Hartree-Fock computations are reported for a methyl isocyanide polymer (repeating unit -C═N-CH 3 ), whose most stable conformation is expected to be a helical chain. The computations used a standard contracted Gaussian orbital set at the computational levels STO-3G, 3-21G, 6-31G, and 6-31G**, and studies were made for two line-group configurations motivated by earlier work and by studies of space-filling molecular models: (1) A structure of line-group symmetry L9 5 , containing a 9-fold screw axis with atoms displaced in the axial direction by 5/9 times the lattice constant, and (2) a structure of symmetry L4 1 that had been proposed, containing a 4-fold screw axis with translation by 1/4 of the lattice constant. Full use of the line-group symmetry was employed to cause most of the computational complexity to depend only on the size of the asymmetric repeating unit. Data reported include computed bond properties, atomic charge distribution, longitudinal polarizability, band structure, and the convoluted density of states. Most features of the description were found to be insensitive to the level of computational approximation. The work also illustrates the importance of exploiting line-group symmetry to extend the range of polymer structural problems that can be treated computationally.

  17. Rotational band structure in 132La

    International Nuclear Information System (INIS)

    Oliveira, J.R.B.; Emediato, L.G.R.; Rizzutto, M.A.; Ribas, R.V.; Seale, W.A.; Rao, M.N.; Medina, N.H.; Botelho, S.; Cybulska, E.W.

    1989-01-01

    '3'2La was studied using on-line gamma-spectroscopy through the reactions '1 24,126 Te( 11,10 B, 3, 4n) 132 La. The excitation function was obtained with 10 B(E lab =41.4; 45.4 and 48 MeV) in order to identify 132 La gamma-transitions. Gamma-gamma coincidences and angular distributions were performed for the 126 Te( 10 B, 4n) 132 La reaction. From the experimental results a rotational band with strongest M1 transitions and less intense 'cross-overs' E2 transitions was constructed. Using the methods of Bengtsson and Frauendorf the alignment (ix) and the Routhian (e') as a function of the angular velocity (ω) were also obtained from the experimental data. It was observed a constant alignment up to ω≅0.4 MeV, and a signature-splitting Δe'=25keV. Preliminary triaxial Cranking-Shell Model calculations indicate that a γ=-8deg deformation is consistent with the signature-splitting value of 25 keV experimentally observed. (Author) [es

  18. Band structure, band offsets, substitutional doping, and Schottky barriers of bulk and monolayer InSe

    Science.gov (United States)

    Guo, Yuzheng; Robertson, John

    2017-09-01

    We present a detailed study of the electronic structure of the layered semiconductor InSe. We calculate the band structure of the monolayer and bulk material using density functional theory, hybrid functionals, and G W . The band gap of the monolayer InSe is calculated to be 2.4 eV in screened exchange hybrid functional, close to the experimental photoluminescence gap. The electron affinities and band offsets are calculated for vertical stacked-layer heterostructures, and are found to be suitable for tunnel field effect transistors (TFETs) in combination with WS e2 or similar. The valence-band edge of InSe is calculated to lie 5.2 eV below the vacuum level, similar to that for the closed shell systems HfS e2 or SnS e2 . Hence InSe would be suitable to act as a p -type drain in the TFET. The intrinsic defects are calculated. For Se-rich layers, the Se adatom (interstitial) is found to be the most stable defect, whereas for In-rich layers, the Se vacancy is the most stable for the neutral state. Antisites tend to have energies just above those of vacancies. The Se antisite distorts towards a bond-breaking distortion as in the EL2 center of GaAs. Both substitutional donors and acceptors are calculated to be shallow, and effective dopants. They do not reconstruct to form nondoping configurations as occurs in black phosphorus. Finally, the Schottky barriers of metals on InSe are found to be strongly pinned by metal induced gap states (MIGS) at ˜0.5 eV above the valence-band edge. Any interfacial defects would lead to a stronger pinning at a similar energy. Overall, InSe is an effective semiconductor combining the good features of 2D (lack of dangling bonds, etc.) with the good features of 3D (effective doping), which few others achieve.

  19. A UWB Band-Pass Antenna with Triple-Notched Band Using Common Direction Rectangular Complementary Split-Ring Resonators

    Directory of Open Access Journals (Sweden)

    Bo Yan

    2013-01-01

    Full Text Available A novel ultrawideband (UWB antenna which has a triple-band notch function is presented. The proposed antenna can block interfering signals from C-band satellite communication systems, IEEE802.11a, and HIPERLAN/2 WLAN systems for example. The antenna is excited by using novel common direction rectangular complementary split-ring resonators (CSRR fabricated on radiating patch of the dielectric substrate with coplanar waveguide (CPW feed strip line. The voltage standing wave ratio (VSWR of the proposed antenna is less than 2.0 in the frequency band from 2.8 to 12 GHz, while showing a very sharp band-rejection performance at 3.9 GHz, 5.2 GHz, and 5.9 GHz. The measurement results show that the proposed antenna provides good omnidirectional field pattern over its whole frequency band excluding the rejected band, which is suitable for UWB applications.

  20. Metal release profiles of orthodontic bands, brackets, and wires: an in vitro study.

    Science.gov (United States)

    Wendl, B; Wiltsche, H; Lankmayr, E; Winsauer, H; Walter, A; Muchitsch, A; Jakse, N; Wendl, M; Wendl, T

    2017-11-01

    The present study evaluated the temporal release of Co Cr, Mn, and Ni from the components of a typical orthodontic appliance during simulated orthodontic treatment. Several commercially available types of bands, brackets, and wires were exposed to an artificial saliva solution for at least 44 days and the metals released were quantified in regular intervals using inductively coupled plasma quadrupole mass spectrometry (ICP-MS, Elan DRC+, Perkin Elmer, USA). Corrosion products encountered on some products were investigated by a scanning electron microscope equipped with an energy dispersive X-ray microanalyzer (EDX). Bands released the largest quantities of Co, Cr, Mn, and Ni, followed by brackets and wires. Three different temporal metal release profiles were observed: (1) constant, though not necessarily linear release, (2) saturation (metal release stopped after a certain time), and (3) an intermediate release profile that showed signs of saturation without reaching saturation. These temporal metal liberation profiles were found to be strongly dependent on the individual test pieces. The corrosion products which developed on some of the bands after a 6-month immersion in artificial saliva and the different metal release profiles of the investigated bands were traced back to different attachments welded onto the bands. The use of constant release rates will clearly underestimate metal intake by the patient during the first couple of days and overestimate exposure during the remainder of the treatment which is usually several months long. While our data are consistent with heavy metal release by orthodontic materials at levels well below typical dietary intake, we nevertheless recommend the use of titanium brackets and replacement of the band with a tube in cases of severe Ni or Cr allergy.