WorldWideScience

Sample records for band wiring technique

  1. Minimally invasive tension band wiring technique for olecranon fractures.

    Science.gov (United States)

    Takada, Naoya; Kato, Kenji; Fukuta, Makoto; Wada, Ikuo; Otsuka, Takanobu

    2013-12-01

    Some types of implants, such as plates, screws, wires, and nails, have been used for open reduction and internal fixation of olecranon fractures. A ≥ 10 cm longitudinal incision is used for open reduction and internal fixation of olecranon fractures. According to previous studies, tension band wiring is a popular method that gives good results. However, back out of the wires after the surgery is one of the main postoperative complications. Moreover, if the Kirschner wires are inserted through the anterior ulnar cortex, they may impinge on the radial neck, supinator muscle, or biceps tendon. Herein, we describe the minimally invasive tension band wiring technique using Ring-Pin. This technique can be performed through a 2 cm incision. Small skin incisions are advantageous from an esthetic viewpoint. Ring-Pin was fixed by using a dedicated cable wire that does not back out unless the cable wire breaks or slips out of the dedicated metallic clamp. As the pins are placed in intramedullary canal, this technique does not lead to postoperative complications that may occur after transcortical fixation by conventional tension band wiring. Minimally invasive tension band wiring is one of the useful options for the treatment of olecranon fractures with some advantages.

  2. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.

    Science.gov (United States)

    Hsu, Kai-Lan; Chang, Wei-Lun; Yang, Chyun-Yu; Yeh, Ming-Long; Chang, Chih-Wei

    2017-12-01

    Modified tension band wiring has been widely used to treat transverse patellar fractures. However, few studies have evaluated the clinical outcomes using different methods of Kirschner wire bending, location of the tension band, and depths of Kirschner wires. Thus, we tried to clarify these factors according to our clinical outcomes. This retrospective cohort study recruited consecutive patients underwent surgical fixation for patellar fractures using modified tension band technique between January 2010 and December 2015. Different factors in this procedure, including the bending manner of the Kirschner wires, their depth, and location of the tension band with respect to the superior and inferior border of the patella were recorded and analysed. The primary outcome was early loss of fixation. The secondary outcomes were minor loss of reduction, implant breakage, deep infection, and the need for implant removal. This study included 170 patients with patellar fractures. Regarding the bending method, similar results were obtained with bilaterally or proximally bent Kirschner wires. Regarding length, the tension band was placed closely (within 25% of the patella length) in 124 patients and distantly in 46 patients. The rates of loss of reduction and implant breakage were significantly higher in the distantly placed tension bands. Regarding depth, 37 patellar fractures were fixed with the Kirschner wires at the superficial one third of the patellae while the K- wires at the middle layer of patella were used in the remaining 133 patellar fractures. A significantly higher rate of minor loss of reduction was obtained using the superficial Kirschner wires. The modified tension band technique for transverse patella fractures provides favourable clinical outcomes, with low failure (5%) and infection (2%) rates. Implant irritation is the major complication, and almost half of cases require implant removal. The location of the tension band with respect to the superior and

  3. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.

    Science.gov (United States)

    Zderic, Ivan; Stoffel, Karl; Sommer, Christoph; Höntzsch, Dankward; Gueorguiev, Boyko

    2017-08-01

    The aim of this study was to investigate the validity of the dynamic compression principle of tension band wiring in two techniques for patella fracture treatment. Twelve human cadaveric knees with simulated transverse patella fractures were assigned to two groups for treatment with tension band wiring using either Kirschner (K-) wires or cannulated screws. Biomechanical testing was performed over three knee movement cycles between 90° flexion and 0° full extension. Pressure distribution in the fracture gap and fracture site displacement were evaluated at the 3 rd cycle in 15° steps, namely 90°-75°-60°-45°-30°-15°-0° extension phase and 0°-15°-30°-45°-60°-75°-90° flexion phase. Mean anterior / posterior interfragmentary pressure in the groups with K-wires and cannulated screws ranged within 0.16-0.40MPa / 0.12-0.35MPa and 0.37-0.59MPa / 0.10-0.30MPa, respectively. These changes remained non-significant for both groups and loading phases (P≥0.171). Mean anterior / posterior fracture site displacement for K-wires and cannulated screws ranged within -0.01-0.53mm / 0.11-0.74mm and 0.11-0.55mm / -0.10-0.50mm, respectively. Anterior displacement remained without significant changes for both groups and loading phases (P≥0.112). However, posterior displacement underwent a significant increase in the course of knee extension for K-wires (P≤0.047), but not for cannulated screws (P≥0.202). Significantly smaller displacement at the posterior fracture site was detected in the group with cannulated screws compared to K-wires at 60° and 75° extension phase (P≤0.017), as well as at 45°, 60° and 75° flexion phase (P≤0.018). The critical value of 2mm displacement at the posterior fracture site was not reached for any specimen and fixation technique. Knee extension was accompanied by synchronous increase in quadriceps pulling force. Tension band wiring fulfills from a biomechanical perspective the requirements for sufficient stability of transverse

  4. Modified tension band wiring technique for olecranon fractures: where and how should the K-wires be inserted to avoid articular penetration?

    Science.gov (United States)

    Özsoy, Mehmet Hakan; Kızılay, Onur; Günenç, Ceren; Özsoy, Arzu; Demiryürek, Deniz; Hayran, Mutlu; Erçakmak, Burcu; Sakaoğulları, Abdurrahman

    2015-01-01

    Articular penetration of K-wires is a possible complication of the modified tension band wiring technique. However, there is no clear information or evidence regarding the entry point or introduction angle for K-wires to avoid this complication. The aim of this experimental study was to evaluate the effect of varying K-wire insertion points and angles on the risk for articular penetration during modified tension band wiring for olecranon fractures. All anatomical measurements were made on 50 cadaveric ulnas, and all other measurements were performed on exact foam replications of the 50 cadaveric ulnas. Morphometric measurements, including olecranon height and heights of the central, radial and ulnar facets of the semilunar notch, were taken. In the sagittal plane, articular angle and tubercle angle were measured. Two 1.6-mm parallel K-wires were inserted from 0, 5 and 8 mm anterior to the dorsal cortex of the olecranon process at angles of 20° and 30°. K-wire articular penetration was evaluated both visually and radiographically. The mean central, radial and ulnar heights of the semilunar notch were 17.3 mm (14.7-20.0), 16.2 mm (12.0-21.0) and 15.8 mm (13.30-20.5), respectively. We observed no articular penetration at the 0-mm level at 20° and 30° (0 mm 20° and 0 mm 30°, respectively) or at 5 mm 20°. At 8 mm 30° wire introduction, more than 64% articular penetration was observed on either facet. The sequence from least to most likely to cause articular penetration was: 0 mm = 5 mm 20° > 5 mm 30° = 8 mm 20° > 8 mm 30°. The radial height of the semilunar notch was negatively correlated to the risk of articular penetration, when the wire was introduced at 8 mm 30°, 8 mm 20° and 5 mm 30° (all pwiring technique to prevent articular penetration, K-wires should be inserted in the first 5 mm from dorsal cortex of the olecranon process at a maximum angle of 20°. Moreover, if the wires are required to be inserted more anteriorly because of the anatomical

  5. Tension band wiring fi xation is associated with good functional ...

    African Journals Online (AJOL)

    Background: Tension band wiring (TBW) is a widely accepted technique for olecranon fractures. Various investigators have reported a significant rate of complications especially hardware prominence. The purpose of this study was to determine the clinical and radiological outcome after tension band wiring of olecranon ...

  6. WIRELESS TENSION BAND WIRING FOR OLECRANON FRACTURES. Case Series.

    Science.gov (United States)

    Roukoz, Sami; Bayoud, Wael

    2016-01-01

    This retrospective study evaluates the results of wireless tension band wire (WTBW) which is a modified technique of tension band wires (TBW) for Mayo type II A and III A olecranon fractures. In this technique the K-wires of the TBW are replaced by a cerclage wire while keeping the figure of eight wiring. We reviewed retrospectively our WTBW cases done between 2000 and 2015 where we replaced the K-wires by a cerclage wire. In this technique no hardware migration is possible. Patients were evaluated clinically, radiographicaly and a DASH score was measured. Seventeen patients were reviewed with a mean age of 58.5 years. The mean follow-up period was 58.5 months. The mean DASH score was 12 with 7 patients having a DASH score of zero. Joint mobility was near normal compared to the other side with loss of a mean of 4º in elbow extension and a mean of 3º in elbow flexion. In comparison with other series, in addition to good results, hardware removal for medical reasons was the lowest in our technique. It was needed in three patients for pain on elbow contact and in one with ulnar nerve irritation. This represents a rate of 23.5%. Undesirable events related to the use of K-wires in standard tension band wiring, such as wire migration, wire protrusion through the skin and wire impingement, are absent in the wireless tension band wiring. The high rate of patient satisfaction, good clinical results as well as low rate of needed hardware removal make this technique preferable for fixing Mayo Type II A olecranon fractures.

  7. Investigation of electrically active defects in InGaAs quantum wire intermediate-band solar cells using deep-level transient spectroscopy (DLTS) technique

    OpenAIRE

    Al Saqri, Noor alhuda; Felix, Jorlandio F.; Aziz, Mohsin; Kunets, Vasyl P.; Jameel, Dler Adil; Taylor, David; Henini, M.; Abd El-sadek, Mahmmoud S.; Furrow, Colin; Ware, Morgan E.; Benamara, Mourad; Mortazavi, Mansour; Salamo, Gregory

    2016-01-01

    InGaAs quantum wire (QWr) intermediate-band solar cell based nanostructures grown by molecular beam epitaxy are studied. The electrical and interface properties of these solar cell devices, as determined by current–voltage (I–V) and capacitance–voltage (C-V) techniques, were found to change with temperature over a wide range of 20–340 K. The electron and hole traps present in these devices have been investigated using deep-level transient spectroscopy (DLTS). The DLTS results showed that the ...

  8. Percutaneous tension band wiring for patellar fractures.

    Science.gov (United States)

    Rathi, Akhilesh; Swamy, M K S; Prasantha, I; Consul, Ashu; Bansal, Abhishek; Bahl, Vibhu

    2012-08-01

    To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. 20 patients underwent successful percutaneous tension band wiring. The remaining 3 patients in whom closed reduction failed underwent open reduction and tension band wiring. The mean operating time was 46 (range, 28-62) minutes. The mean follow-up period was 20 (range, 15-30) months. At the latest follow-up, all patients had regained full extension. The objective score was excellent in 20 patients and good in 3, whereas the subjective score was excellent in 17, good in 5, and fair in one. All patients had radiological union at week 8. One patient had patellofemoral arthritis (secondary to a postoperative articular step). Two patients developed superficial infections, which resolved after antibiotic therapy. Mean thigh muscle wasting was 0.7 (range, 0.4-1) cm. Three patients encountered hardware problems (impingement/irritation of the skin over the knee) necessitating implant removal. Percutaneous tension band wiring is a viable option for transverse fractures of the patella.

  9. A biomechanical comparison of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for fixation of the cervical spine.

    Science.gov (United States)

    Brasil, A V; Coehlo, D G; Filho, T E; Braga, F M

    2000-07-01

    The authors conducted a biomechanical study in which they compared the uses of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for internal fixation of the cervical spine. An extensive biomechanical evaluation (stiffness in positive and negative rotations around the x, y, and z axes; range of motion in flexion-extension, bilateral axial rotation, and bilateral bending; and neutral zone in flexion-extension, bilateral axial rotation, and lateral bending to the right and to the left) was performed in two groups of intact calf cervical spines. After these initial tests, all specimens were subjected to a distractive flexion Stage 3 ligamentous lesion. Group 1 specimens then underwent surgical fixation by the Rogers technique, and Group 2 specimens underwent surgery by using the Lovely-Carl technique. After fixation, specimens were again submitted to the same biomechanical evaluation. The percentage increase or decrease between the pre- and postoperative parameters was calculated. These values were considered quantitative indicators of the efficacy of the techniques, and the efficacy of the two techniques was compared. Analysis of the findings demonstrated that in the spines treated with the Lovely-Carl technique less restriction of movement was produced without affecting stiffness, compared with those treated with the Rogers technique, thus making the Lovely-Carl technique clinically less useful.

  10. Double tension band wiring for treatment of olecranon fractures.

    Science.gov (United States)

    Kim, Wanlim; Choi, Sunghun; Yoon, Jun O; Park, Ho Youn; Kim, Sun Hwa; Kim, Jin Sam

    2014-12-01

    Although tension band wiring (TBW) is generally accepted as standard treatment for olecranon fractures, it has several shortcomings such as loss of reduction, skin irritation, and migration of the K-wires. To overcome these problems and increase fixation stability, we used a rigid fixation technique with double tension band wiring (DTBW). Here, we describe the technique and outcomes of the treatment. We retrospectively reviewed 21patients with olecranon fractures who were treated by DTBW. We evaluated clinical and radiological outcomes by checking the range of motion, loss of reduction, functional scoring, skin complications, and pin migration. There were 15 cases of Mayo type IIA fractures (71%) and 6 of type IIB fractures (29%). The mean follow-up period was 37 months (range, 12-58 mo). We also compared the mechanical stability of DTBW and TBW in a sawbone model using a single cycle load to failure protocol. All fractures united without displacement, and no migration of the K-wires was observed during the period of follow-up. Mean loss of elbow extension was 2° (range, 0°-15°) and mean elbow flexion was 134° (range, 125°-140°). The mean Mayo Elbow Performance Score was 94 (range, 70-100). Biomechanical testing revealed greater mechanical strength in the DTBW technique than in the TBW when measured by mean maximum failure load and mean bending moment at failure. DTBW produced good clinical and radiological outcomes and could be an effective option for the treatment of olecranon fractures by providing additional stability through a second TBW. Biomechanical comparison with a control group (TBW) supported the mechanical benefits of DTBW. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Restrictive techniques: gastric banding

    Directory of Open Access Journals (Sweden)

    Katia Cristina da Cunha

    2006-03-01

    Full Text Available Surgery for the treatment of severe obesity has a definite role onthe therapeutic armamentarium all over the world. Initiated 40years ago, bariatric surgery has already a long way thanks tohundred of surgeons, who had constantly searched for the besttechnique for the adequate control of severe obesity. Among theimportant breakthroughs in obesity surgery there is theadjustable gastric band. It is a sylastic band, inflatable andadjustable, which is placed on the top of the stomach in order tocreate a 15-20 cc pouch, with an outlet of 1.3cm. The adjustablegastric band has also a subcutaneous reservoir through whichadjustments can be made, according to the patient evolution.The main feature of the adjustable gastric band is the fact thatis minimal invasive, reversible, adjustable and placedlaparoscopically. Then greatly diminishing the surgical traumato the severe obese patient. Belachew and Favretti’s techniqueof laparoscopic application of the adjustable gastric band isdescribed and the evolution of the technique during this years,as we has been practiced since 1998. The perioperative care ofthe patient is also described, as well as the follow-up and shortand long term controls.

  12. Complications and re-operation rate after tension-band wiring of olecranon fractures

    DEFF Research Database (Denmark)

    Romero, J M; Miran, A; Jensen, Claus Hjorth

    2000-01-01

    Tension-band wire fixation of olecranon fractures leads to a high re-operation rate because of the need to remove the metalware. This problem has commonly been thought to be related mainly to the backing-out of the Kirschner wires. A retrospective study was carried out in 55 patients with displaced...... olecranon fractures operated on with the tension-band wiring technique, in whom there was an overall 71.7% re-operation rate. Complications were few and minor in most patients. The main reason for the removal of the metalware was a direct complaint from the patient (in 61.3% of all removals). A literature...

  13. COMPARATIVE STUDY BETWEEN TENSION BAND WIRING OF PATELLAR FRACTURES WITH KIRSCHNER WIRES AND CANNULATED SCREWS IN TERMS OF FUNCTIONAL OUTCOME AND COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Kumaran Chettiar

    2016-11-01

    Full Text Available BACKGROUND Various treatment modalities are described for the treatment of displaced transverse fractures of patella. As patella is very important biomechanically, open reduction and internal fixation with maximal preservation of patella is the standard treatment. Most commonly used method is modified tension band wiring with Kirschner wires. In a modification, cannulated screws are used instead of K wires and wire is passed through the cannulation of the screw and anterior surface of the patella. The aim of our study was to compare the complications and functional outcomes after surgical treatment of patellar fractures using modified tension band wiring with Kirschner wires and with cannulated screws. MATERIALS AND METHODS This study was conducted in Department of Orthopaedics, Government Medical College, Kozhikode, during the period 2014- 2015. Total sample size was 36. They were randomised into two groups. Among them, 17 had undergone tension band wiring with cannulated screws and 19 with Kirschner wires. They were evaluated in postoperative period at 1 month, 3 months and 6 months by looking for complications like postoperative infection, postoperative loss of reduction, skin irritation by prominent hardware. Functional outcome was assessed by knee pain score and Good Fellows grading of range of motion. RESULTS According to this study while comparing these two surgical techniques, there are no statistically significant differences in terms of complications and functional outcome. We observed that cannulated screw with tension band wiring has better patient tolerance, less complications like skin irritation by prominent hardware, loss of fixation and knee pain. We found that tension band wiring through cannulated screws is technically more difficult than using Kirschner wires. CONCLUSION Although, the statistical analysis showed no significant differences regarding the union and final outcome, cannulated screw with tension band wiring has

  14. Wiring System Diagnostic Techniques for Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Ageing Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...be identified. Additionally, wiring failures tend to be intermittent in nature and can take considerable time to isolate. Wire modifications and

  15. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report.

    Science.gov (United States)

    Aydın, Ekrem; Dülgeroğlu, Turan Cihan; Metineren, Hasan

    2016-02-24

    Patella fractures represent 1 % of all musculoskeletal system fractures. Fixation of patellar fractures using open reduction and tension band wiring is a commonly used and successful surgical fixation method. A 28-year-old male patient from Turkey presented to our clinic with complaints of palpable foreign bodies under the skin on the dorsolateral side of his right foot. Except for the palpable and moving body of about 6 cm length under the skin in his foot, he had no functional complaints. On X-ray, a Kirschner wire was visible in front of the lateral malleolus on the dorsolateral side of his right foot. In addition, there was a cerclage wire from the tension band fixation of his patella in the ipsilateral knee. The Kirschner wire was removed surgically. Despite the use of different fixation materials for the surgical treatment of patellar fractures, tension band wiring is still a commonly used technique. We recommend that after fixation of a patellar fracture using the tension band wiring technique, the ends of the Kirschner wires be bent and the wires then removed in the early phase after patellar union to prevent Kirschner wire migration.

  16. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.

    Science.gov (United States)

    Kim, Jin Young; Lee, Young Ho; Gong, Hyun Sik; Lee, Sang Lim; Lee, Sang Ki; Baek, Goo Hyun

    2013-09-01

    To evaluate the clinical and radiographic outcomes of tension band wiring of displaced olecranon fractures treated using Kirschner wires with eyelets to assess their clinical performance with respect to complications such as backing out of the K-wires, restriction of forearm rotation, and neurovascular injury. The authors retrospectively reviewed 44 patients treated for an isolated, displaced olecranon fracture and checked range of motion, postoperative pain, complications, and incidence of hardware removal. The mean follow-up period was 41 months (range, 26-73 mo). All fractures united, and anatomical reduction was achieved in all cases at final follow-up. Mean elbow flexion was 135° (range, 115° to 140°), and mean elbow extension was 4° (range, 0° to 15°). No pin migration, restriction of forearm rotation, or neurovascular injury occurred. Hardware removal was performed in 8 cases (18%). Compared to previous results with conventional Kirschner wires, no meaningful improvement in postoperative pain level or in the rate of hardware removal was observed. Tension band wiring using the pin studied produced excellent clinical and radiologic outcomes for the treatment of isolated, displaced Mayo type IIA and some type IIB olecranon fractures. The pin was effective in preventing the backing out of Kirschner wires and avoiding the complications associated with anterior cortical engagement of Kirschner wires, such as neurovascular injury or restriction of forearm rotation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Genetic programming techniques for thin-wire antennas

    Science.gov (United States)

    O'Donnell, Terry H.

    2007-04-01

    Simple genetic algorithm optimizations often utilize fixed-length chromosomes containing a predefined set of parameters to be optimized. While such algorithms have successfully created electrically small narrow-band and large wide-band military antennas, they require the antenna designer to have a fairly concrete antenna representation prior to exercising the genetic algorithm. In this research we investigate the use of genetic programming (GP) techniques to "program" the design of simple thin-wire antennas. Genetic programming techniques offer the potential to create random, multi-arm, multi-dimension antennas from variable length, tree-like chromosomes. We present a new genetic programming paradigm for creating multi-branched, thin-wire, genetic antennas and describe how GP commands are represented and decoded into physical antenna structures. We present preliminary results obtained from this algorithm showing evolutions along Pareto fronts representing antenna electrical size, VSWR, and antenna quality factor (Q).

  18. Cancellous screw with tension band wiring for fractures of the olecranon.

    Science.gov (United States)

    S M, Raju; Gaddagi, Rashmi A

    2013-02-01

    Olecranon fractures are one of the most commonly seen orthopaedic injuries in the emergency room. The K-wire which is used in the AO Tension Band Wiring (TBW) technique resists the shear better than the figure of eight wire alone, but, it does not add compression to the fixation strength. But, the cancellous screw plus the tension band wire, in combination, provides the strength of fixation i.e., by converting the tensile force to a compressive force at the fracture site, with additional resistance to the displacement due to the lag screw compression. To clinically evaluate the result of the cancellous screw with tension band wiring for fractures of the olecranon.To assess the elbow joint motion and stability after the procedure. Tweenty five cases of fractures of the olecranon which were treated by using 6.5mm AO cancellous screws with a screw length of 80-105mm with a 16 gauge TBW, were evaluated . All the cases were followed up and the results were analyzed by using a 19 point scale. The results which were obtained in our series were excellent in 15(60%) patients, good in 3(12%) patients and fair in 7(28%) patients and there were no poor results. The technique of open reduction and internal fixation with a 6.5mm AO cancellous screw and TBW, is a simple and effective means of treating fractures of the olecranon and it is based on the biomechanical principle of sound.

  19. A STUDY ON THE MANAGEMENT OF DISPLACED FRACTURES OF PATELLA USING MODIFIED TENSION BAND WIRING

    Directory of Open Access Journals (Sweden)

    Hari Babu

    2015-10-01

    Full Text Available INTRODUCTION: Patella is an important component of the extensor mechanism of the knee. A patella fracture constitutes 1% of all skeletal fractures resulting from either direct or indirect trauma. Any improper and inadequate treatment would inevitably lead to a disability which would be most perceptibly felt in a country like India, where squatting is important activity in daily life. The goal of treatment is to regain the continuity of the extensor mechanism and congruity of patellofemoral a rticulation so that the normal function of the knee can be restored. Several techniques have been described for internal fixation of fractures of patella. The ideal fixation for the fracture patella is that it should be strong enough to allow early mobiliz ation, reduce posttraumatic stiffness and perhaps help the healing of the articular surface . AIMS: To analyze the functional outcome of displaced transverse fractures of the patella treated by Modified Tension Band Wiring principle (Muller using A. Dutta & S. K. Gupta Scoring System. To extend the application of Modified Tension Band wiring for minimally comminuted fractures of patella and assesses the results. CONCLUSION : The present study shows that modified tension band wiring (Muller is an effective p rocedure in the management of displaced transverse patellar fractures, with excellent to good results. Minimally comminuted patellar fractures also yielded excellent to good results with Modified tension band wiring as an extended application. The results in the present study are comparable to other modifications of Tension Band Wiring principle. The surgery of Modified Tension Band Wiring gives rigid fixation and helps in early mobilization. Regular and scheduled post- operative physiotherapy plays an impor tant role in the functional outcome.

  20. Cockpit canopy shattering using exploding wire techniques

    International Nuclear Information System (INIS)

    Novac, B M; Smith, I R; Downs, P R; Marston, P; Fahey, D

    2007-01-01

    This paper presents the principal experimental results provided by a preliminary investigation into the possibility of using exploding wire (EW) techniques to shatter the plastic cockpit canopy of a modern jet aircraft. The data provided forms the basis for a qualitative understanding of the physics of interaction between the plasma produced by an EW and the surrounding elasto-plastic material in which the wire is embedded. To optimize the shock-wave 'clean cutting' effect, the significance of the material, the dimensions of the exploding wire and the amplitude of the current and voltage pulses are all considered. This leads to important conclusions concerning both the characteristics of the EW and the optimum arrangement of the electrical circuit, with the single most important optimization factor being the peak electrical power input to the EW, rather than the dissipated Joule energy. A full-scale system relevant to an actual cockpit canopy shattering is outlined and relevant results are presented and discussed

  1. FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures.

    Science.gov (United States)

    Wright, P B; Kosmopoulos, V; Coté, R E; Tayag, T J; Nana, A D

    2009-11-01

    The metal implants used to achieve fixation of displaced transverse patellar fractures are associated with implant failure, postoperative pain and a significant re-operation rate. Recent studies have examined braided suture as a possible alternative to stainless steel wire to increase patient satisfaction and decrease re-operation rates, but suture has not demonstrated clearly superior fixation strength. FiberWire is a reinforced braided polyblend suture that has demonstrated superior characteristics to the previous sutures studied and has not to our knowledge been examined as a material for tension band fixation of transverse patellar fractures. Materials testing was performed on repeated samples of No. 5 FiberWire suture and 18-gauge stainless steel wire. The strength and stiffness of each material was measured. The two materials were then used for tension band fixation on a novel transverse patellar fracture model and tested to failure by three-point bending. The constructs included a single stainless steel wire, a single-strand FiberWire tied with a sliding knot, double-strand FiberWire tied with sliding knots and double-strand FiberWire tied with a Wagoner's Hitch. The fixation strength and stiffness of the constructs were measured. Unlike stainless steel, FiberWire maintained its initial stiffness until failure. Furthermore, during three-point-bend testing, double-strand FiberWire was found to have a significantly higher failure load than stainless steel wire when the suture was tied and locked under the tension produced by a modified Wagoner's Hitch. FiberWire is a potentially superior alternative to stainless steel wire in tension band fixation of transverse patellar fractures.

  2. Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases.

    Science.gov (United States)

    Fournet, Alexandre; Boursier, Jean-François; Corbeau, Solène; Decambron, Adeline; Viateau, Véronique; Fayolle, Pascal; Bedu, Anne-Sophie; Leperlier, Dimitri; Manassero, Mathieu

    2018-01-01

     This article aimed to describe olecranon fracture in dogs and cats and their stabilization with tension band wiring or plate osteosynthesis, and to evaluate complications associated with each technique.  Medical records of cats and dogs that had been surgically treated for olecranon fractures with either tension band wiring or plate osteosynthesis were retrospectively reviewed. The surgical technique, complications and long-term outcomes were assessed.  Forty-one olecranon fractures were included. Fractures were articular, comminuted and open in 90, 31 and 27% of cases, respectively. Tension band wiring and plate osteosynthesis were performed in 22 and 19 fractures, respectively. Complications occurred more commonly after tension band wiring (74%) compared with plate osteosynthesis (27%) ( p  = 0.002) and these were probably related to it being used in comminuted fractures ( p  = 0.01) or to errors in technique. Minor complications included Kirschner wires migration ( n  = 5), pain ( n  = 3), osteomyelitis ( n  = 3), skin breakdown ( n  = 3) and seroma ( n  = 1). Implant failure requiring further fixation ( n  = 4) was observed only in the tension band wiring group. Other major complications included skin wound debridement and closure ( n  = 1) and chronic lameness requiring implant removal ( n  = 7). Long-term functional outcomes were excellent regardless of the technique used.  Plate osteosynthesis should be performed for olecranon fracture repair if technically feasible. Schattauer GmbH Stuttgart.

  3. Polydimethylsiloxane pressure sensors for force analysis in tension band wiring of the olecranon.

    Science.gov (United States)

    Zens, Martin; Goldschmidtboeing, Frank; Wagner, Ferdinand; Reising, Kilian; Südkamp, Norbert P; Woias, Peter

    2016-11-14

    Several different surgical techniques are used in the treatment of olecranon fractures. Tension band wiring is one of the most preferred options by surgeons worldwide. The concept of this technique is to transform a tensile force into a compression force that adjoins two surfaces of a fractured bone. Currently, little is known about the resulting compression force within a fracture. Sensor devices are needed that directly transduce the compression force into a measurement quality. This allows the comparison of different surgical techniques. Ideally the sensor devices ought to be placed in the gap between the fractured segments. The design, development and characterization of miniaturized pressure sensors fabricated entirely from polydimethylsiloxane (PDMS) for a placement within a fracture is presented. The pressure sensors presented in this work are tested, calibrated and used in an experimental in vitro study. The pressure sensors are highly sensitive with an accuracy of approximately 3 kPa. A flexible fabrication process for various possible applications is described. The first in vitro study shows that using a single-twist or double-twist technique in tension band wiring of the olecranon has no significant effect on the resulting compression forces. The in vitro study shows the feasibility of the proposed measurement technique and the results of a first exemplary study.

  4. Tension band wiring for proximal femoral varus osteotomy fixation in children.

    Science.gov (United States)

    Maranho, Daniel Augusto; Pagnano, Rodrigo Gonçalves; Volpon, José Batista

    2014-08-01

    For proximal varus osteotomy of the femur in children, a stable fixation, is a concern regarding the safety and the protection of the surgery. The methods of fixation are mostly represented by plating systems; however, the tension band wiring is a simple and eligible option for fixation of proximal femur osteotomy. The purpose of this retrospective case series study is to evaluate outcomes and bone remodelation after using the tension band wiring technique to fixate proximal femoral varus osteotomies in children.The study enrolled 20 patients who underwent femoral varus osteotomy to treat Legg-Calvé-Perthes disease and other causes of necrosis of the femoral head. The mean patient age at the time of surgery was 7.4 ± 2.3 years (range, 4.3-13.8 y), and the follow-up period averaged 10 ± 4.3 years (range, 4.7-20.8 y). To assess the effects of the osteotomy at the neck-shaft angle and its evolution over time, radiographs obtained preoperatively and during the follow-up were analyzed. The neck-shaft angle was measured independently by 2 observers, and intraclass correlation coefficients (ICCs) were assessed for reliability.The ICC analysis showed good reliability. There was a significant reduction in the neck-shaft angle (P 17 years postsurgery.The tension band wiring technique proved to be a simple and effective method for fixating proximal femoral varus osteotomy in children.The level IV is appropriated for our study (case series, retrospective).

  5. Tension Band Wiring for Proximal Femoral Varus Osteotomy Fixation in Children

    Science.gov (United States)

    Maranho, Daniel Augusto; Pagnano, Rodrigo Gonçalves; Volpon, José Batista

    2014-01-01

    Abstract For proximal varus osteotomy of the femur in children, a stable fixation, is a concern regarding the safety and the protection of the surgery. The methods of fixation are mostly represented by plating systems; however, the tension band wiring is a simple and eligible option for fixation of proximal femur osteotomy. The purpose of this retrospective case series study is to evaluate outcomes and bone remodelation after using the tension band wiring technique to fixate proximal femoral varus osteotomies in children. The study enrolled 20 patients who underwent femoral varus osteotomy to treat Legg–Calvé–Perthes disease and other causes of necrosis of the femoral head. The mean patient age at the time of surgery was 7.4 ± 2.3 years (range, 4.3–13.8 y), and the follow-up period averaged 10 ± 4.3 years (range, 4.7–20.8 y). To assess the effects of the osteotomy at the neck-shaft angle and its evolution over time, radiographs obtained preoperatively and during the follow-up were analyzed. The neck-shaft angle was measured independently by 2 observers, and intraclass correlation coefficients (ICCs) were assessed for reliability. The ICC analysis showed good reliability. There was a significant reduction in the neck-shaft angle (P 17 years postsurgery. The tension band wiring technique proved to be a simple and effective method for fixating proximal femoral varus osteotomy in children. The level IV is appropriated for our study (case series, retrospective). PMID:25101990

  6. Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring

    Directory of Open Access Journals (Sweden)

    Khan I

    2016-07-01

    Full Text Available Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1 or transverse with mildly comminuted (AO34-C2 patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the patients were treated with open reduction and internal fixation using two parallel cannulated screws and 18G stainless steel wire as per the tension band principle. Results: There were eighteen males (72% and seven females (28%. The age group ranged from 24 to 58 years, with mean age of 38 years. The most common mode of injury was fall (72% followed by road traffic accident (20% and violent quadriceps contraction (8%. Transverse fracture was present in 60% and transverse fracture with mild comminution in 40% of patients. Mean time to achieve union was 10.7 weeks (range 8-12 weeks. Mean ROM at three months was 113.8 degree (90-130 and at final follow up this improved to 125.4 degrees (range 100-140. There was one case of knee stiffness and no case of implant failure was observed. Patients were evaluated using Bostman scoring, the mean score at three months being 26.04 which improved to 27.36 at the end of final follow up at one year. Conclusion: Cannulated cancellous screws with anterior tension band wiring is a safe, reliable and reproducible method in management of transverse patellar fractures, with less chances of implant failure and soft tissue irritation.

  7. Arthroscopic Removal of a Wire Fragment from the Posterior Septum of the Knee following Tension Band Wiring of a Patellar Fracture.

    Science.gov (United States)

    Tamaki, Yasuaki; Nakayama, Takashi; Kita, Kenichiro; Miyatake, Katsutosi; Kawasaki, Yoshiteru; Fujii, Koji; Takeda, Yoshitsugu

    2015-01-01

    Tension band wiring with cerclage wiring is most widely used for treating displaced patellar fractures. Although wire breakage is not uncommon, migration of a fragment of the broken wire is rare, especially migration into the knee joint. We describe here a rare case of migration of a wire fragment into the posterior septum of the knee joint after fixation of a displaced patellar fracture with tension band wiring and cerclage wiring. Although it was difficult to determine whether the wire fragment was located within or outside the knee joint from the preoperative plain radiographs or three-dimensional computed tomography (3D CT), we found it arthroscopically through the posterior transseptal portal with assistance of intraoperative fluoroscopy. Surgeons who treat such cases should bear in mind the possibility that wire could be embedded in the posterior septum of the knee joint.

  8. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].

    Science.gov (United States)

    Zhang, J; Jiang, X Y; Huang, X W

    2016-06-18

    To investigate the clinical efficacy and outcomes of two separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella. From January 2013 to January 2015, 15 consecutive patients (mean age 54.5 years) with inferior pole fractures of the patella were retrospectively included in this study. All the patients underwent open reduction and internal fixation by separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire through longitudinal incision, 4.5 d (range: 3.1-5.9 d) after initial injury. A safety check for early knee range of motion was performed before wound closure. The complications including infection, nonunion, loss of fixation and any wire breakage or irritation from implant were recorded. Anteroposterior and lateral views of the knee joint obtained during the follow-up were used to assess bony union based on the time when the fracture line disappeared. At the time of the final outpatient follow up, functional evaluation of the knee joint was conducted by Bostman system. The follow-up time was 13.1 months (range: 12-19 months) after surgery on average, immediate motion without immobilization in all the cases was allowed and there was no case of reduction loss of the fracture and wire breakage. There was no case of irritation from the implant. At the final follow-up, the average range of motion (ROM) arc was 126.7° (range: 115°-140°), the average ROM lag versus contralateral healthy leg was 10.3° (range: 0°-35°). The mean Bostman score at the last follow-up was 28.9 (range: 27-30), and graded excellent in most cases. Two separate vertical wiring is an easy and effective method to reduce the displaced inferior pole fracture of patella. Augmentation of separate vertical wiring with tension band and Kirschner-wire plus cerclage wire in these patients provides enough strength to protected the early exercise of the knee joint and

  9. Comparing the Knotless Tension Band and the Traditional Stainless Steel Wire Tension Band Fixation for Medial Malleolus Fractures: A Retrospective Clinical Study

    Directory of Open Access Journals (Sweden)

    Michael W. Downey

    2016-01-01

    Full Text Available The traditional stainless steel wire tension band (WTB has been popularized for small avulsion fractures at the medial malleolus. Despite the tension band principle creating a stable construct, complications continue to arise utilizing the traditional stainless steel WTB with patients experiencing hardware irritation at the tension band site and subsequent hardware removal. Coupled with hardware irritation is fatigue failure with the wire. The goal of this investigation was to retrospectively compare this traditional wire technique to an innovative knotless tension band (KTB technique in order to decrease costly complications. A total of 107 patients were reviewed with a minimum follow-up of 1 year. Outcome measures include descriptive data, fracture classification, results through economic costs, and fixation results (including hardware status, healing status, pain status, and time to healing. The KTB group had a 13% lower true cost as compared to the WTB group while the fixation results were equivocal for the measured outcomes. Our results demonstrate that the innovative KTB is comparable to the traditional WTB while offering a lower true cost, an irritation free reduction all without the frustration of returning to the operating room for additional hardware removal, which averages approximately to $8,288.

  10. Comparing the Knotless Tension Band and the Traditional Stainless Steel Wire Tension Band Fixation for Medial Malleolus Fractures: A Retrospective Clinical Study.

    Science.gov (United States)

    Downey, Michael W; Duncan, Kyle; Kosmopoulos, Victor; Motley, Travis A; Carpenter, Brian B; Ogunyankin, Fadeke; Garrett, Alan

    2016-01-01

    The traditional stainless steel wire tension band (WTB) has been popularized for small avulsion fractures at the medial malleolus. Despite the tension band principle creating a stable construct, complications continue to arise utilizing the traditional stainless steel WTB with patients experiencing hardware irritation at the tension band site and subsequent hardware removal. Coupled with hardware irritation is fatigue failure with the wire. The goal of this investigation was to retrospectively compare this traditional wire technique to an innovative knotless tension band (KTB) technique in order to decrease costly complications. A total of 107 patients were reviewed with a minimum follow-up of 1 year. Outcome measures include descriptive data, fracture classification, results through economic costs, and fixation results (including hardware status, healing status, pain status, and time to healing). The KTB group had a 13% lower true cost as compared to the WTB group while the fixation results were equivocal for the measured outcomes. Our results demonstrate that the innovative KTB is comparable to the traditional WTB while offering a lower true cost, an irritation free reduction all without the frustration of returning to the operating room for additional hardware removal, which averages approximately to $8,288.

  11. Magnetic properties of iron nanoparticles prepared by exploding wire technique

    OpenAIRE

    Alqudami, Abdullah; Annapoorni, S.; Lamba, Subhalakshmi; Kothari, P C; Kotnala, R K

    2006-01-01

    Nanoparticles of iron were prepared in distilled water using very thin iron wires and sheets, by the electro-exploding wire technique. Transmission electron microscopy reveals the size of the nanoparticles to be in the range 10 to 50 nm. However, particles of different sizes can be segregated by using ultrahigh centrifuge. X-ray diffraction studies confirm the presence of the cubic phase of iron. These iron nanoparticles were found to exhibit fluorescence in the visible region in contrast to ...

  12. Modified tension band wiring fixation for avulsion fractures of the calcaneus in osteoporotic bone: a review of three patients.

    Science.gov (United States)

    Nagura, Issei; Fujioka, Hiroyuki; Kurosaka, Masahiro; Mori, Hiroyuki; Mitani, Makoto; Ozaki, Akihiro; Fujii, Hideo; Nabeshima, Yuji

    2012-01-01

    Calcaneal avulsion fractures are not uncommon, and they are probably more likely in patients with osteoporosis. Closed manipulation for this type of fracture often fails to achieve acceptable reduction, and open reduction and internal fixation are usually required. However, open reduction and internal fixation with either a lag screw or Steinmann pins do not provide satisfactory fixation in patients with diabetes and elderly patients because of the presence of porotic bone. Levi described a tension band fixation system used to treat a calcaneal avulsion fracture using a simple technique performed with a transverse Kirschner wire through the os calcaneus, securing a figure-of-8 metal tension band wiring to the fragment. We report the successful treatment of 3 patients with calcaneal avulsion fractures using a modified tension band wiring technique, resulting in satisfactory recovery. Re-displacement of the fragment during the initial follow-up period was not reported, and bony union was achieved in all patients. We believe this technique is a useful surgical option for the treatment of calcaneal avulsion fractures. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of spinous process wiring techniques for accidental canal penetration.

    Science.gov (United States)

    Adeolu, Augustine A; Azeez, Abiodun L

    2013-04-01

    Accidental canal penetration with attendant complications constitutes one of the reasons for abandoning the use of wires for posterior spinal fusion techniques. However, there is dearth of information on this risk when the wire is introduced through the base of spinous process as against sublaminar passage. This study was designed to evaluate hardware-related postoperative complications, especially canal penetration, in our patients who had spinal process wiring in two types of posterior wiring techniques. Patients who had either of two spinous process wiring techniques formed the population for the study. The clinical records were reviewed and the following data were extracted: Age, sex, diagnosis, operation (fusion type), preoperative neurological status, postoperative neurologic deterioration, other postoperative complication and radiologic evidence of canal encroachment. One hundred and seventy four spinous processes were instrumented in 42 patients. The age of the patients ranged from 11 to 78 years while male to female ratio was 2.5:1. Majority of the spinal wiring were for trauma (29 patients; 69.0) while the remaining were tumor (6; 14.3%), degenerative diseases (4; 9.5%) and infections (3; 7.1%). The Rogers technique was performed in 16 (38.1%) patients while 26 (61.9%) underwent Adeolu et al. technique. One patient (2.3%) had neurologic deterioration while 5 patients (11.1%) had varying type of complications from wound infection to fracture of spinous processes. There was no patient with radiological or clinical evidence of canal compromise. Spinous process wiring techniques for posterior spinal stabilization appears to be safe as demonstrated in this study.

  14. Successful percutaneous coronary intervention for complex bifurcated lesions with combination of "Reverse wire technique" and "Reverse bent wiring with the crusade catheter" novel wire manipulation technique.

    Science.gov (United States)

    Nomura, Tetsuya; Higuchi, Yusuke; Kato, Taku

    2016-04-01

    We encountered a case of percutaneous coronary intervention for complex bifurcated lesions in the mid portion of the left anterior descending (LAD) artery. The diagonal artery branched from the LAD artery with a markedly angulated pattern and there was severe stenosis from just proximal to this diagonal artery. The "reverse wire technique facilitated with the Crusade catheter" enabled us to cross a guidewire through to the markedly angulated diagonal side branch (SB). Next, we adopted a mini-crushing stent strategy for this true bifurcated lesion. Thereafter, we adopted "reverse bent wiring with the Crusade catheter" for wire re-crossing to the incarcerated side branch, and successfully completed all procedures. This technique for successful wire re-crossing is simple but can be very effective in specific situations in practical percutaneous coronary intervention (PCI). Many PCI operators may empirically adopt this kind of wire manipulation technique. However, this case is the first report in the world describing the application of a "reverse bent wiring with the Crusade catheter" for wire re-crossing through a double-folded stent strut to a SB at the optimal point of the bifurcation. In this case, we made the most of the Crusade catheter. This catheter is a very useful device for multifactorial use in practical PCI. It can help us to perform complex PCI procedures successfully. © 2015 Wiley Periodicals, Inc.

  15. Ureteroscopy during pregnancy with follow-the-wire technique ...

    African Journals Online (AJOL)

    Requirement for analgesia was reduced due to placement of stents. Stent-related complaints were tolerable. All patients completed full-term pregnancy. Conclusion: Ureteral obstruction during pregnancy can be safely managed ureteroscopically using the follow-the-wire technique. It obviates the need for ionizing radiation.

  16. Tunable dual-band subwavelength imaging with a wire medium slab loaded with nanostructured graphene metasurfaces

    Directory of Open Access Journals (Sweden)

    Ali Forouzmand

    2015-07-01

    Full Text Available In this paper, we demonstrate that a wire medium slab loaded with graphene-nanopatch metasurfaces (GNMs enables the enhancement of evanescent waves for the subwavelength imaging at terahertz (THz frequencies. The analysis is based on the nonlocal homogenization model for wire medium with the additional boundary condition at the connection of wires to graphene. The physical mechanism behind this lens can be described as the surface plasmons excitement at the lower and upper GNMs which are coupled by an array of metallic wires. The dual nature (capacitive/inductive of the GNM is utilized in order to design a dual-band lens in which the unique controllable properties of graphene and the structural parameters of wire medium (WM slab provide more degrees of freedom in controlling two operating frequency bands. The lens can support the subwavelength imaging simultaneously at two tunable distinct frequencies with the resolution better than λ/6 even if the distance between GNMs is a significant fraction of wavelength (>λ/5.5. The major future challenges in the fabrication of the lens have been demonstrated and a promising approach for the practical configuration of the lens has been proposed.

  17. Does K-wire position in tension band wiring of olecranon fractures affect its complications and removal of metal rate?

    Science.gov (United States)

    Chan, K W; Donnelly, K J

    2015-06-01

    Despite the recognised complications of migration of wires and soft tissue irritation, tension band wiring (TBW) remains the gold standard for fixation of displaced, minimally comminuted olecranon fractures. There is much variation in placement of the K-wires with current AO guidance stating that each wire should be drilled through the anterior cortex and then backed up by 1 cm. The aim of this study was to examine the effect of K-wire position (intramedullary vs. transcortical) on stability of the construct and significant local complications. All patients who underwent TBW for an isolated olecranon fracture in our trauma unit between 1/1/2009 and 31/12/2011 were included in this retrospective study. Mean follow-up was 14 months (range 5-29 months). Data was gathered from medical records and radiographs. The outcome measured was removal of metal due to complications such as wound problems or proximal migration of wires as standard practice within out trauma unit. Sixty-three patients met the inclusion criteria. Forty-seven had an intramedullary compared with 16 with transcortical configuration (ratio 3:1). Nine patients (19%) with intramedullary K-wires required removal of metalwork - seven due to prominent metalwork and two with wound infection. Four patients (25%) with transcortical K-wires required removal of metalwork - three due to prominent metalwork and one with failure of metalwork. There was no significant statistical difference between transcortical and intramedullary K-wire placement with regards to complication rates following tension band wiring of an isolated olecranon fracture requiring removal of metal (Chi squared test with Yates' correction p = 0.89). We concluded that we found no difference in complications or metalwork removal rate in the placement of K-wire in tension band wiring for isolated olecranon fracture. We recognise our study was limited by small numbers and is based on the experience of one trauma unit.

  18. Tension band wiring of the olecranon: is it really a dynamic principle of osteosynthesis?

    Science.gov (United States)

    Brink, P R G; Windolf, M; de Boer, P; Brianza, S; Braunstein, V; Schwieger, K

    2013-04-01

    The tension band principle as applied to transverse olecranon fractures fixed by tension band wiring is based on the premise that distraction forces on the outer cortex of the ulna during elbow flexion are converted to compression forces on the articular surface of the olecranon at the fracture site. In view of some clinical outcomes, where hardware failure and secondary dislocations occur, the question arises if the dynamic compression theory is correct. Compressive forces during active flexion and extension after tension band wiring of a transverse osteotomy of the olecranon were measured in 6 fresh frozen human cadaveric models using a pressure-sensor in the osteotomy gap. We could collect 30 measurements during active flexion and 30 during active extension. Active flexion did not cause any compressive forces in the osteotomy gap. Extension with the humerus in an upright position and the elbow actively extended causes some compression (0.37-0.51 MPa) at the articular surface comparing with active flexion (0.2 MPa) due to gravity forces. Posterior, there was no significant pressure difference observed (0.41-0.45 versus 0.36-0.32 MPa) between active flexion and extension. The tension band wiring principle only exists during active extension in a range of 30-120° of flexion of the elbow. Postoperative exercise programs should be modified in order to prevent loss of compression at the fracture site of transverse olecranon fractures, treated with tension band wiring when the elbow is mobilised. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Olecranon Process Fracture in a Radial Club Hand Treated with Tension Band Wiring: A Case Report.

    Science.gov (United States)

    Biradar, Ramanagouda; Pillai, Arravind; Shetty, Ullas

    2016-01-01

    Radial club hand is rare deformity, and many patients do not receive treatment due to lack of awareness. None of the treatment options available can restore normality. Fractures of the olecranon process in radial club hand are rare probably due to limited use of the limb. We report the case of a 35-year-old male with radial club hand who presented with a transverse fracture of the olecranon process. The patient underwent open reduction and tension band wiring for the fracture. At 6 months follow-up, the fracture had united and the patient had a complete functional recovery. Tension band wiring is an excellent option for treating olecranon fractures in patients with radial club hand despite the deformity and the absence of radius.

  20. Rectangular waveguide-to-coplanar waveguide transitions at U-band using e-plane probe and wire bonding

    DEFF Research Database (Denmark)

    Dong, Yunfeng; Johansen, Tom Keinicke; Zhurbenko, Vitaliy

    2016-01-01

    This paper presents rectangular waveguide-to-coplanar waveguide (CPW) transitions at U-band (40–60 GHz) using E-plane probe and wire bonding. The designs of CPWs based on quartz substrate with and without aluminum cover are explained. The single and double layer rectangular waveguide......-to-CPW transitions using E-plane probe and wire bonding are designed. The proposed rectangular waveguide-to-CPW transition using wire bonding can provide 10 GHz bandwidth at U-band and does not require extra CPWs or connections between CPWs and chips. A single layer rectangular waveguide-to-CPW transition using E...

  1. Temperature dependence of quantum-wire intermediate-band solar cells

    Science.gov (United States)

    Sarollahi, Mirsaeid; Kunets, Vasyl P.; Mazur, Yuriy I.; Mortazavi, Mansour; Salamo, Gregory J.; Ware, Morgan

    2017-02-01

    This work investigates the performance of an intermediate band solar cell (IBSC) structure based on InGaAs/GaAs lateral quantum wires under elevated temperature. Un-optimized structures using the same quantum wire based IB material have demonstrated an increase in solar conversion efficiency in comparison with reference GaAs P-I-N diode devices. In order to further understand the physics behind this increase, an optimized structure was developed and characterized. The External Quantum Efficiencies (EQE) of doped and Un-doped samples have been measured using these optimized designs. We present here the results of varying both applied bias and temperature on the EQE of these IBSC devices to highlight the advantages of such a structure.

  2. Posterior tension band wiring and instrumentation for thoracolumbar flexion-distraction injuries.

    Science.gov (United States)

    Hasankhani, E G; Omidi-Kashani, F

    2014-04-01

    To evaluate treatment outcome of tension band wiring followed by posterior spinal fusion and instrumentation for thoracolumbar flexiondistraction injury (FDI). 36 men and 12 women aged 21 to 56 (mean, 36) years underwent tension band wiring followed by posterior spinal fusion and instrumentation using pedicular screws for FDI of the thoracolumbar spine. The injured vertebral levels were T11 (n=2), T12 (n=12), T11-T12 (n=1), T12-L1 (n=1), L1 (n=28), and L2 (n=4). Anterior vertebral body height and kyphosis were measured before and after surgery. Neurologic status was assessed using the American Spinal Injury Association (ASIA) scale. The Oswestry Disability Index questionnaire and visual analogue scale for pain were also used. The mean follow-up was 38 (range, 26-72) months. At final follow-up, the mean visual analogue scale for pain was 1.7, and the median Oswestry Disability Index was 4% (range, 0-32%). The mean anterior vertebral body height improved from 20.5 to 38.8 mm (pwiring followed by posterior spinal fusion and instrumentation for thoracolumbar FDIs achieved good outcome.

  3. A clever technique for placement of a urinary catheter over a wire

    Directory of Open Access Journals (Sweden)

    Joel E Abbott

    2015-01-01

    Conclusion: Placing urinary catheters over a wire is standard practice for urologists, however, use of this technique gives the freedom of performing wire-guided catheterization in more situations than a council-tip allows. This technique facilitates successful transurethral catheterization over wire in the setting of DUC for all catheter types and styles aiding in urologic management of patients at a cost benefit to the health care system.

  4. A comparative study in fixation methods of medial malleolus fractures between tension bands wiring and screw fixation.

    Science.gov (United States)

    Mohammed, Ayyoub A; Abbas, Khalid Ahmed; Mawlood, Ammar Salah

    2016-01-01

    The aim of this study is to compare two methods of internal fixations of fractured medial malleolus which are simple screw fixation and tension band wiring. Over 5 years we grouped 20 patients with fractured medial malleolus into two groups of operative treatments, group1 treated by malleolar screw fixation and group2 by tension band wiring. The patients were with same age group, gender, fracture type, and etiology. We use statistical analysis for make a comparative study between the two ways of surgical treatment. The mean time for radiologic bone union was 11.8 weeks in group1 patients and 9.4 weeks in group2 patients (P = 0.03). No patients had any sign of fixation failure or Kirschner wires migration. According to the modified ankle scoring system of Olerud and Molander, excellent and good results were achieved in 80 % in group1 patients and 90 % in group2 patients (P = 0.049). Tension-band wiring may be better treatment option for internal fixation of medial malleolar fractures than screw fixation. From these findings we recommend a further randomized clinical trial of larger number of cases and longer follow-up duration in order to regard tension-band wiring a better operative option for fixation of medial malleolar fractures.

  5. The laparoscopic banded gastric bypass – operation technique

    Directory of Open Access Journals (Sweden)

    Simon Küsters

    2010-03-01

    Full Text Available The banded Roux-en-Y gastric bypass can be used as a primary or revisionary bariatric procedure. This article describesthe operation technique including materials, size and placement of the banding and gives an overview con cerningevolution and indications of the operation. A video of a primary banded Roux-en-Y gastric bypass is presented.

  6. InGaAs/InP quantum wires grown on silicon with adjustable emission wavelength at telecom bands.

    Science.gov (United States)

    Han, Yu; Li, Qiang; Ng, Kai Wei; Zhu, Si; Lau, Kei May

    2018-03-08

    We report the growth of vertically stacked InGaAs/InP quantum wires on (001) Si substrates with adjustable room-temperature emission at telecom bands. Based on a self-limiting growth mode in selective area metal-organic chemical vapor deposition, crescent-shaped InGaAs quantum wires with variable dimensions are embedded within InP nano-ridges. With extensive transmission electron microscopy studies, the growth transition and morphology change from quantum wires to ridge quantum wells have been revealed. As a result, we are able to decouple the quantum wires from ridge quantum wells and manipulate their dimensions by scaling the growth time. With minimized lateral dimension and their unique positioning, the InGaAs/InP quantum wires are more immune to dislocations and more efficient in radiative processes, as evidenced by their excellent optical quality at telecom-bands. These promising results thus highlight the potential of combining low-dimensional quantum wire structures with the aspect ratio trapping process for integrating III-V nano-light emitters on mainstream (001) Si substrates. © 2018 IOP Publishing Ltd.

  7. Comparison of tension band wiring and precontoured locking compression plate fixation in Mayo type IIA olecranon fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Raschke, Michael J; Groene, Philipp; Weimann, André; Wähnert, Dirk; Lenschow, Simon; Kösters, Clemens

    2014-03-01

    Aim of the present study was to compare the clinical and radiographic outcome of tension band wiring and precontoured locking compression plate fixation in patients treated surgically for an isolated olecranon fractures type IIA according to the Mayo classification. Of 26 patients presenting with an isolated Mayo type IIA olecranon fracture, 13 underwent fixation with a precontoured locking compression plate (group A), 13 patients were treated with tension band wiring (group B). At a mean follow-up of 43 months, patients were clinically and radiographically re-examined using the DASH score, the Mayo Elbow Performance score (MEPS) and anteroposterior and lateral radiographs. The mean DASH score was 14 points in group A and 12.5 points in group B. Regarding the MEPS, 92% of the patients in group A achieved a good to excellent results in comparison to 77% in group B. No significant differences between the two groups could be detected regarding the clinical and radiographic outcome. Implant-related irritations requiring hardware removal occurred more frequently in group B (12 vs. 7). Procedure and implant related costs were significantly higher in group A. Tension band wiring is still a preferable surgical method to treat simple isolated olecranon fractures. The patient must be informed that in all likelihood implant removal will be required once the fracture has healed. Fixation with precontoured locking compression plates does not provide better functional and radiographic outcome but is more expensive than tension band wiring.

  8. Arthroscopic Reduction and Fixation of Tibial Spine Avulsion Fractures by a Stainless Steel Wiring Technique.

    Science.gov (United States)

    Abdelhamid, Mohamed M; Bayoumy, Maysara Abdelhalim; Elkady, Hesham A; Abdelkawi, Ayman Farouk

    2017-12-01

    Several techniques of arthroscopic treatment of tibial spine avulsion fractures have been described in the literature. These techniques include the use of various fixation devices such as screws, K-wires, wiring, sutures, and suture anchors. In this study, we evaluate a new wiring technique for the treatment of these injuries. This technique involves fixation by stainless steel tension wires passed over the fractured spine and tied over a bone bridge. The advantages of this technique are that it aids in reduction, allows for compression of the tibial spine fragment anatomically in its fracture bed, provides stable fixation in difficult comminuted fractures, and allows for early mobilization and weight bearing because of the solid fixation.

  9. Percutaneous tracheostomy with the guide wire dilating forceps technique : presentation of 171 consecutive patients

    NARCIS (Netherlands)

    Fikkers, Bernard G; van Heerbeek, Niels; Krabbe, Paul F M; Marres, Henri A M; van den Hoogen, Frank J A

    BACKGROUND: Evaluation of percutaneous tracheostomy (PT) with the guide wire dilating forceps (GWDF) technique. METHODS: Prospective study of perioperative complications, retrospective analysis of early and late complications in an ICU in a teaching university hospital. RESULTS: The success rate of

  10. Percutaneous tracheostomy with the guide wire dilating forceps technique: presentation of 171 consecutive patients.

    NARCIS (Netherlands)

    Fikkers, B.G.; Heerbeek, N. van; Krabbe, P.F.M.; Marres, H.A.M.; Hoogen, F.J.A. van den

    2002-01-01

    BACKGROUND: Evaluation of percutaneous tracheostomy (PT) with the guide wire dilating forceps (GWDF) technique. METHODS: Prospective study of perioperative complications, retrospective analysis of early and late complications in an ICU in a teaching university hospital. RESULTS: The success rate of

  11. Randomized prospective study of olecranon fracture fixation: cable pin system versus tension band wiring.

    Science.gov (United States)

    Liu, Q-H; Fu, Z-G; Zhou, J-L; Lu, T; Liu, T; Shan, L; Liu, Y; Bai, L

    2012-01-01

    This prospective, randomized study compared the effectiveness of the cable pin system (CPS) versus tension band wiring (TBW) for olecranon fracture fixation. Patients with acute transverse or slight oblique olecranon fractures were randomly divided into two groups: one fixed by CPS and the other by TBW. Clinical outcome data were collected and analysed following a mean duration of 21 months. The mean ± SD fracture healing time was significantly shorter in the CPS group (n = 30; 9.73 ± 2.02 weeks) compared with the TBW group (n = 32; 11.13 ± 2.21 weeks). One patient in the CPS group and seven patients in the TBW group experienced postoperative complications; this difference was statistically significant. The mean ± SD Mayo Elbow Performance Score in the CPS group was significantly higher (88.67 ± 6.42) than that in the TBW group (80.78 ± 11.99). Logistic regression analysis showed an association between fixation method and fracture healing time, complications and elbow function. Internal fixation by CPS is an effective method for olecranon fracture and is associated with a shorter healing time, fewer complications and better function than TBW.

  12. Comparison between optical techniques and confocal microscopy for defect detection on thin wires

    Energy Technology Data Exchange (ETDEWEB)

    Siegmann, Philip; Sanchez-Brea, Luis Miguel; Martinez-Anton, Juan Carlos; Bernabeu, Eusebio

    2004-11-15

    Conventional microscopy techniques, such as atomic force microscopy (AFM), scanning electron microscopy (SEM), and confocal microscopy (CM) are not suitable for on-line surface inspection of fine metallic wires. In the recent years, some optical techniques have been developed to be used for those tasks. However, they need a rigorous validation. In this work, we have used confocal microscopy to obtain the topography z(x,y) of wires with longitudinal defects, such as dielines. The topography has been used to predict the light scattered by the wire. These simulations have been compared with experimental results, showing a good agreement.

  13. Comparison between optical techniques and confocal microscopy for defect detection on thin wires

    International Nuclear Information System (INIS)

    Siegmann, Philip; Sanchez-Brea, Luis Miguel; Martinez-Anton, Juan Carlos; Bernabeu, Eusebio

    2004-01-01

    Conventional microscopy techniques, such as atomic force microscopy (AFM), scanning electron microscopy (SEM), and confocal microscopy (CM) are not suitable for on-line surface inspection of fine metallic wires. In the recent years, some optical techniques have been developed to be used for those tasks. However, they need a rigorous validation. In this work, we have used confocal microscopy to obtain the topography z(x,y) of wires with longitudinal defects, such as dielines. The topography has been used to predict the light scattered by the wire. These simulations have been compared with experimental results, showing a good agreement

  14. Application of hot-wire technique at unconventional conditions

    Science.gov (United States)

    Lebiga, V. A.; Pak, A. Yu.; Zinoviev, V. N.; Mironov, D. S.

    2017-10-01

    The problems of using the hot-wire method for studying fluctuations in flows are considered when standard approaches and conventional modes cannot be used due to constraints caused either by the flow parameters or by the characteristics and conditions of the experiments. Examples of measurements under conditions of extremely low pressures and beyond the limits of the continuity of the medium in the CO2-laser are given; The use of data of hot-wire measurements for the determination of sources of disturbances in test sections of high-speed wind tunnels is shown; the design of a probe for measurement of concentration of components of the binary gas mixture is described, etc.

  15. New technique for wiring SSC superconducting sextupole corrector coils

    International Nuclear Information System (INIS)

    Leon, B.

    1985-01-01

    There exists in the electronics industry, a technology for the manufacture of printed circuit (PC) boards which is directly transferable into the creation of highly controlled coils, such as the SSC sextupole superconducting corrector coils. This technology, which uses a process of laying down insulated wire in highly controlled patterns has heretofore been confined exclusively to the manufacture of high density printed circuit (PC) boards, possibly due to an ignorance of its utility in the field of precision winding of coils. This ability to fix wires in a well defined location can be used to produce precision wound coils in a very cost-effective manner. These coils may be superior in quality to conventionally made coils. Before describing what can be created with this technology, it is necessary to take a look at this coil winding process, the MULTIWIRE process, and the industry which has utilized this technology

  16. A new technique for wiring SSC superconducting sextupole corrector coils

    International Nuclear Information System (INIS)

    Leon, B.

    1985-01-01

    There exists in the electronics industry, a technology for the manufacture of printed circuit (PC) boards which is directly transferable into the creation of highly controlled coils, such as the SSC sextupole superconducting corrector coils. This technology, which uses a process of laying down insulated wire in highly controlled patterns, has heretofore been confined excusively to the manufacture of high density printed circuit (PC) boards, possibly due to an ignorance of its utility in the field of precision winding of coils. This ability to fix wires in a well defined location can be used to produce precision wound coils in a very cost-effective manner. These coils may be superior in quality to conventionally made coils. Before describing what can be created with this technology, it is necessary to take a look at this coil winding process, the MULTIWIRE process, and the industry which has utilized this technology

  17. William Edward Gallie (1882-1959): father of the Gallie wiring technique for atlantoaxial arthrodesis.

    Science.gov (United States)

    Dossani, Rimal Hanif; Shaughnessy, John; Kalakoti, Piyush; Nanda, Anil

    2018-03-01

    William Edward Gallie (1882-1959) was a Canadian general surgeon with special expertise in orthopedic surgery. His experience with surgical management of cervical spine subluxation led him to invent a method of cervical wiring of the atlas to the axis. His method of C1-2 wiring has since been modified, but it still remains one of the three most commonly taught wiring techniques in neurosurgical training programs. Gallie is also hailed for instituting the first surgical training program in Canada, a curriculum his pupils memorialized as the "Gallie course" in surgery. In this historical vignette, the authors describe Gallie's life and depict his contributions to surgery.

  18. Wiring technique for lesser trochanter fixation in proximal IM nailing of unstable intertrochanteric fractures: A modified candy-package wiring technique.

    Science.gov (United States)

    Kim, Gyeong Min; Nam, Kwang Woo; Seo, Kyu-Bum; Lim, Chaemoon; Kim, Jiyun; Park, Yong-Geun

    2017-02-01

    The purpose of this study was to introduce a new surgical technique, that involves modified Candy-package wiring followed by IM nailing fixation and to determine the clinical and radiological results obtained in patients with unstable intertrochanteric fractures with a lesser trochanter fragment. This study included 22 patients who were undergone proximal IM nailing with lesser trochanter wiring between January 2014 to June 2015. All patients were treated with minimally invasive technique of candy-package wiring for lesser trochanter fragments. The mean age was 75.8 years (range, 53-88) and average follow-up period was 15.1 months (range, 12-24). Each patient was followed up for a minimum of 12 months and their clinical and radiological results were analyzed. The mean period required for fracture union was 16.6 weeks. (range, 8-25) and union was successfully completed in all cases. The WOMAC scores at the last F/U visit (average; 45.4, range; 21-75) were not significantly different to pre-trauma status (average; 36.5, range; 19-59) (p=0.087). In comparison of ambulatory capacity prior to trauma, ambulatory aggravation was noted in four cases (18.2%), and eighteen cases (81.8%) was sustained walking ability of prior of trauma. Wiring breakage was found in two cases and heterotrophic ossification in one case. There were no functional deficeit related to the radiologic finding in these patients. With regard to postoperative complications, were no cut-outs, breakage, or pullout of screws. When surgically repairing unstable intertrochanteric fractures with lesser trochanter comminution using proximal IM nailing method, the modified Candy-packaging wiring technique increases the fixation force at the fracture site. Thus, through this technique, both firm fixation of the lesser trochanter and more stable bony union were obtained. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A comparative evaluation of the tensile strength of silver soldered joints of stainless steel and cobalt chromium orthodontic wires with band material--an in vitro study.

    Science.gov (United States)

    Dua, R; Nandlal, B

    2004-03-01

    The present study was conducted to compare and evaluate the tensile strength of silver soldered joints of stainless steel and cobalt-chromium orthodontic wires with band material. An attempt was made to observe the effect of joint site preparation by incorporation of tack welding and increasing metal to metal surface contact area by flattening an end of the wire prior to soldering along with the regularly used round wires without tack welding. A total of 180 wire specimens were soldered to 180 band specimens. Fifteen samples according to joint site preparation were included for each of the wire groups i.e. Gloria (S.S.), Remanium (S.S.) and Remaloy (Co-Cr) wires of 0.036" in diameter. The findings of the study were suggestive that all three wires may be used for preparing silver soldered joints irrespective of the quality of the wire. However, when subjecting the wire to joint site preparation, Gloria (S.S.) wire showed less tensile strength as compared to Remanium and Remaloy.

  20. Crusade Microcatheter-Facilitated Reverse Wire Technique for Revascularization of Bifurcation Lesions of Coronary Arteries.

    Science.gov (United States)

    Lee, Hsin-Fu; Chou, Shing-Hsien; Tung, Ying-Chang; Lin, Chia-Pin; Ko, Yu-Shien; Chang, Chi-Jen

    2018-01-01

    This study aims to analyze the lesion characteristics of bifurcations that required reverse wire technique and the efficacy and safety of this technique in approaching branches with a highly angulated take-off. We enrolled patients in whom reverse wire technique was used after failed conventional antegrade wiring with the support of a Crusade catheter. The study endpoints were the technical success defined as succeeding in sending the reversely bent wire to the targeted branches without complications and the procedural success defined as succeeding in revascularization of the bifurcation lesions without complications. Among 158 patients with bifurcation lesions undergoing percutaneous coronary intervention using a Crusade catheter to facilitate wiring, 23 (14.6%) requiring the reverse wire technique in an attempt to access branches of the bifurcation lesions with an acutely angulated take-off were enrolled for analysis. The obtainable angle of take-off was 162.9 ± 4.7 degrees. For the parent vessel, the ostium of the targeted branch, and nontargeted branch, the minimal luminal diameters were 0.3 ± 0.5 mm, 0.4 ± 0.2 mm, and 1.8 ± 0.5 mm, respectively; the diameter stenosis were 88.8 ± 18.5%, 83.0 ± 7.3%, and 32.0 ± 14.5%, respectively. Technical and procedural success was achieved in 22 cases (96% for both). We showed in the present study that the reverse wire technique is effective and safe for approaching highly angulated branches of bifurcation lesions and consequently for complete revascularization of difficult bifurcation lesions.

  1. [Treatment of isolated fractures of the olecranon: percutaneous double-screw fixation versus conventional tension band wiring].

    Science.gov (United States)

    Uhlmann, M; Barg, A; Valderrabano, V; Weber, O; Wirtz, D C; Pagenstert, G

    2014-07-01

    Isolated fractures of the olecranon account for 7-10% of all osseous injuries in adults. These fractures are usually treated surgically by conventional tension band wiring. The percutaneous double-screw fixation is an optional treatment in patients with two fragment olecranon fractures with some postoperative advantages. A total of 13 patients with isolated fractures of the olecranon (Schatzker-Schmelling type A) treated by percutaneous double-screw fixation were included in this prospective study. The mean age of patients was 43.6 ± 11.0 years. Intraoperative and postoperative complications were recorded. Functional results were assessed after a mean follow-up of 38.2 ± 11.5 months using the Quick-DASH score. The results were compared with those obtained in the control group including 26 patients treated by conventional tension band wiring. No intraoperative complications were observed in both groups. In the group with percutaneous double-screw fixation the scar length was significantly shorter (2.4 ± 0.4 cm vs. 11.0 ± 1.8 cm, p wiring with 38.5 % and 73.1 %, respectively. At the minimum follow-up of 2 years comparable functional results were obtained in both groups (Quick-DASH score 2.3 vs. 0.0 points, respectively, p = 0.155); however, the range of elbow motion was significantly higher in the group with percutaneous double-screw fixation (extension/flexion 145° vs. 130°, p wiring; however, range of elbow motion and cosmetic results were significantly better in the patient group with percutaneous double-screw fixation.

  2. A retrospective comparison of the modified tension band technique and the parallel titanium cannulated lag screw technique in transverse patella fracture.

    Science.gov (United States)

    Wang, Cheng-Xue; Tan, Lei; Qi, Bao-Chang; Hou, Xiang-Feng; Huang, Yu-Long; Zhang, Hai-Peng; Yu, Tie-Cheng

    2014-01-01

    To compare efficacy between the modified tension band technique and the parallel titanium cannulated lag screw technique for the transverse patella fracture. Seventy-two patients were retrospectively analyzed aged 22 to 79 years (mean, 55.6 years) with transverse patella fractures, among whom 37 patients underwent the modified tension band and 35 patients received the titanium cannulated lag screw. Patients were followed up for 1-3 years. We analyzed the difference of operation time, complications, fracture reduction, fracture healing time, and the Iowa score for knee function between both groups. In modified tension band group, five patients had skin irritation and seven suffered wire migration, two of whom required a second operation. In comparison, there were no complications in the titanium cannulated lag screw group, which also had a higher fracture reduction rate and less operation time. The parallel titanium cannulated lag screw technique has superior results and should be considered as an alternative method to treat transverse patella fracture.

  3. Minimally Invasive Calcaneal Displacement Osteotomy Site Using a Reference Kirschner Wire: A Technique Tip.

    Science.gov (United States)

    Lee, Moses; Guyton, Gregory P; Zahoor, Talal; Schon, Lew C

    2016-01-01

    As a standard open approach, the lateral oblique incision has been widely used for calcaneal displacement osteotomy. However, just as with other orthopedic procedures that use an open approach, complications, including wound healing problems and neurovascular injury in the heel, have been reported. To help avoid these limitations, a percutaneous technique using a Shannon burr for calcaneal displacement osteotomy was introduced. However, relying on a free-hand technique without direct visualization at the osteotomy site has been a major obstacle for this technique. To address this problem, we developed a technical tip using a reference Kirschner wire. A reference Kirschner wire technique provides a reliable and accurate guide for minimally invasive calcaneal displacement osteotomy. Also, the technique should be easy to learn for surgeons new to the procedure. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis.

    Science.gov (United States)

    Ren, Yi-Ming; Qiao, Hu-Yun; Wei, Zhi-Jian; Lin, Wei; Fan, Bao-You; Liu, Jun; Li, Ang; Kang, Yi; Liu, Shen; Hao, Yan; Zhou, Xian-Hu; Feng, Shi-Qing

    2016-11-14

    Olecranon fracture (OF) is a common upper limb fracture, and the most commonly used techniques are still tension band wiring (TBW) and plate fixation (PF). The aim of the current study is to discuss whether TBW or PF technique of internal fixation is better in the treatment of OFs, using the method of meta-analysis. The eligible studies were acquired from PubMed, CNKI, Embase, Cochrane Library, and other sources. The data were extracted by two of the coauthors independently and were analyzed by RevMan5.3. Standardized mean differences (SMDs), odds ratios (ORs), and 95% confidence intervals (CIs) were calculated. Cochrane Collaboration's Risk of Bias Tool and Newcastle-Ottawa Scale were used to assess risk of bias. Thirteen studies including 1 RCT and 12 observational studies were assessed. Our meta-analysis results showed that both in RCT and observational studies, there were no significant differences between the two groups in disabilities of the arm, shoulder and hand (DASH) (SMD = 0.07, 95% CI = -0.32 to 0.46, p = 0.73), improvement rate (OR = 0.76, 95% CI = 0.48-1.22, p = 0.26), range of motion (ROM), operation time (SMD = -0.51, 95% CI = -1.17 to 0.14, p = 0.12) and blood loss (SMD = -0.97, 95% CI = -2.06 to 0.11, p = 0.08). The overall estimate of complications indicated that the pooled OR was 2.61 (95% CI = 1.65-4.14, p < 0.0001), suggesting that the difference was statistically significant. We also compared the outcomes of patients with mayo type IIA OFs treated by TBW and PF in DASH and ROM and found no differences. Both TBW and PF interventions had treatment benefit in OFs. The current study reveals that there are no significant differences in DASH, improvement rate, ROM, operation time, and blood loss between TBW and PF for OFs. Due to the less complications, we recommend the PF approach as the optical choice for OFs. More high-quality studies are required to further confirm our results.

  5. Synthesis of Band Filters and Equalizers Using Microwav FIR Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Deibele, C.; /Fermilab

    2000-01-01

    It is desired to design a passive bandpass filter with both a linear phase and flat magnitude response within the band and also has steep skirts. Using the properties of both coupled lines and elementary FIR (Finite Impulse Response) signal processing techniques can produce a filter of adequate phase response and magnitude control. The design procedure will first be described and then a sample filter will then be synthesized and results shown.

  6. Conductance of Conjugated Molecular Wires: Length Dependence, Anchoring Groups, and Band Alignment

    DEFF Research Database (Denmark)

    Peng, Guowen; Strange, Mikkel; Thygesen, Kristian Sommer

    2009-01-01

    characteristic of tunneling through a barrier, G = Gc exp(−βL). For thiophene, pyrrole, and phenyl wires with thiol end-groups, we calculate decay constants (β) of 0.211, 0.257, and 0.264 Å−1, respectively, and contact conductances (Gc) of 1.25, 2.90, and 1.22G0, where G0 = 2e2/h is the conductance quantum....... In comparison, the corresponding values for amine-terminated thiophene are calculated to be β = 0.160 Å−1 and Gc = 0.038G0. These results show that (1) the contact resistance is mainly determined by the anchoring group and (2) the decay constant, which determines the conductance in the long wire limit......The conductance of π-conjugated molecular wires bonded to gold electrodes at zero bias is studied using density functional theory combined with nonequilibrium Green’s function method. For all systems considered, we find that the conductance length dependence follows the simple exponential law...

  7. Microcatheter balloon pinning technique to facilitate wiring of a left circumflex chronic total occlusion.

    Science.gov (United States)

    Oguayo, Kevin N; Oguayo, Chris C; Vallabhan, Ravi; Choi, James W

    2017-12-01

    Coronary chronic total occlusions (CTOs) are commonly encountered during diagnostic angiograms. With recent advances, especially in experienced centers, success rates with CTO percutaneous coronary intervention (PCI) have approached 80% or higher. It is important to note that despite these advancements in techniques, CTOs remain difficult to treat. We present a case of a left circumflex artery (LCX) CTO that was successfully revascularized using a microcatheter balloon pinning technique that allowed additional wire support. A 77-year-old woman status post-two-vessel coronary artery bypass graft surgery presented with new onset angina at rest and was found to have a patent graft to the left anterior descending artery, and an unrevascularized proximal LCX CTO. PCI was attempted with a microcatheter using an antegrade approach. This approach was unsuccessful due to the lack of support and the left circumflex angle. As a result, we used a balloon to pin the microcatheter to the wall of the left main to allow for successful wiring of the LCX. A stent was successfully deployed in the LCX, and the patient was discharged from the hospital 2 days later. At follow-up, the patient was asymptomatic and returned to her usual activity. After conducting a thorough literature search, it appears that this is the first case that a microcatheter has been pinned with a balloon. We believe that in LCX CTOs that require support, the microcatheter pinning technique can provide adequate support in wiring CTO's. LCX CTOs can be very difficult to treat, we present a case of a LCX CTO that required the use of the microcatheter balloon pinning technique to allow additional wire support for successful wiring and ultimately treatment. © 2017 John Wiley & Sons Ltd.

  8. The usefulness of wire-loop technique for percutaneous angioplasty of insufficient hemodialysis fistula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hun; Goo, Dong Erk; Kim, Dae Ho; Choi, Deuk Lin; Moon, Chul [College of Medicine, Soonchunhyang University, Seoul (Korea, Republic of)

    2000-10-01

    To evaluate the usefulness of the wire-loop technique, used to perform percutaneous transluminal angioplasty (PTA) in occluded arteriovenous fistula when standard methods fail to pass the balloon catheter across the stenotic segment. In 30 patients (M:F = 14:16; aged 27-77 (mean, 51.3) years), the Wire-Loop technique was used to perform percutaneous transluminal angioplasty of insufficiently hemodialysed arteriovenous fistula where a balloon catheter had failed to pass through the stenotic lesion after a guide wire had successfully passed. Native and Gore-tex fistula were used in 22 and eight cases, respectively.Sixteen stenoses were located in the central vein, and fourteen in the peripheral. The puncture sites used in order to perform the technique were the femoral vein in all cases of central stenosis; three basilic, four cephalic, and five femoral veins in cases of peripheral stenosis and one femoral and one radial artery in cases of anastomotic stenosis. The guide wire was passed through the stenotic lesion, pulled out using the snare technique, and then stretched in order to tighten it. The balloon catheter was then passed through the lesion and traditional balloon angioplasty was performed. The technical success rate and complications of the technique, and the patency rate of recanalized arteriovenous fistula, were evaluated. In 26 of the thirty patients, (86.7%), the procedure was technically successful. In the remaining four cases, failure was due to venous dissection (n=1), marked residual stenosis (n=2), or cardiac arrest (n=1) during the procedure. The average procedure time was 105 (range, 40-210) minutes, and in three cases rupture of the vein occurred. The patency rate of PTA was 80% (24/30) at four months, 63% (19/30) at six months, and 30% (9/30) at twelve months. The expected technical success rate of traditional PTA, without the Wire-Loop technique, would have been 79.3%, but using the technique, the rate increased to 86.7%. The Wire

  9. Apical wiring technique in surgical treatment of adolescent idiopathic scoliosis: the intermediate outcomes between Lenke types.

    Science.gov (United States)

    Chaiyamongkol, Weera; Klineberg, Eric O; Gupta, Munish C

    2013-02-01

    Retrospective cohort study of apical wiring technique for surgical treatment of adolescent idiopathic scoliosis patients. To evaluate the intermediate outcome of adolescent idiopathic scoliosis patients treated with apical wiring technique. Regarding surgical treatment for adolescent idiopathic scoliosis, there are reports of the superiority of coronal plane correction using all-screw constructs compared with all-hook or hybrid constructs. Major limitations of all-screw constructs are thoracic hypokyphosis and increased proximal junctional kyphosis. There are few reports about apical wiring technique outcomes and no reports of this surgical technique comparing Lenke types. Consecutive adolescent idiopathic scoliosis patients treated with apical wiring technique were analyzed. Inclusion criteria were patient 21 years old or younger, who underwent a posterior only surgical correction with a follow-up of at least 2 years. Radiographic data were analyzed according to the criteria given by Lenke and colleagues. The radiographic parameters included global balance, Cobb angle, curve flexibility, apical vertebral translation, tilt angle of lower instrumented vertebra, angle of caudal disk to the lower instrumented vertebra, thoracic kyphosis, lumbar lordosis, and proximal junctional angle preoperatively and postoperatively. There was a significant improvement of Cobb angle in every Lenke type with an average correction of 74.6%. At latest follow-up, the average loss of correction was 3.5% (1.9 degrees). The greatest loss of correction for the minor curve of Lenke 2 was 14.1% (5.8 degrees). There was an improvement of thoracic kyphosis in hypokyphosis group (1.9-21.1 degrees; Pwiring technique for surgical treatment of adolescent idiopathic scoliosis provides an average correction of 71.1% at 3.4 years of average follow-up with harmonious sagittal plane correction even with preexisting abnormal thoracic kyphosis.

  10. Band structure of a three-dimensional topological insulator quantum wire in the presence of a magnetic field.

    Science.gov (United States)

    Liu, Zhe; Jiang, Liwei; Zheng, Yisong

    2016-07-13

    By means of a numerical diagonalization approach, we calculate the electronic structure of a three-dimensional topological insulator (3DTI) quantum wire (QW) in the presence of a magnetic field. The QW can be viewed as a 3DTI film with lateral surfaces, when its rectangular cross section has a large aspect ratio. Our calculation indicates that nonchiral edge states emerge because of the confined states at the lateral surfaces. These states completely cover the valence band region among the Landau levels, which reasonably account for the absence of the [Formula: see text] quantum Hall effect in the relevant experimental works. In an ultrathin 3DTI film, inversion between the electron-type and hole-type bands occurs, which leads to the so-called pseudo-spin Hall effect. In a 3DTI QW with a square cross section, a tilting magnetic field can establish well-defined Landau levels in all four surfaces. In such a case, the quantum Hall edge states are localized at the square corners, characterized by the linearly crossing one-dimensional band profile. And they can be shifted between the adjacent corners by simply rotating the magnetic field.

  11. LENR BEC Clusters on and below Wires through Cavitation and Related Techniques

    Science.gov (United States)

    Stringham, Roger; Stringham, Julie

    2011-03-01

    During the last two years I have been working on BEC cluster densities deposited just under the surface of wires, using cavitation, and other techniques. If I get the concentration high enough before the clusters dissipate, in addition to cold fusion related excess heat (and other effects, including helium-4 formation) I anticipate that it may be possible to initiate transient forms of superconductivity at room temperature.

  12. O método de fio quente: técnica em paralelo e técnica de superfície The hot wire method: the hot wire parallel technique and the hot wire surface technique

    Directory of Open Access Journals (Sweden)

    W. N. dos Santos

    2002-06-01

    Full Text Available A condutividade térmica é uma das propriedades físicas mais importantes de um material. A sua determinação experimental apresenta algumas dificuldades e requer alta precisão na determinação dos fatores necessários para o seu cálculo. O método de medida de condutividade térmica para materiais refratários mais usado hoje em todo o mundo, tanto nos centros de pesquisa, quanto nos laboratórios industriais, é o Método do Fio Quente, onde a condutividade térmica é calculada a partir do transiente de temperatura gerado por uma fonte de calor ideal, infinitamente longa e fina num meio material infinito. Neste trabalho são comparados os resultados obtidos utilizando-se duas técnicas diferentes para a detecção do transiente térmico: numa delas, a temperatura é medida na superfície do fio quente, (técnica de fio quente de superfície, e na outra, a temperatura é medida a uma certa distância do fio quente (técnica de fio quente paralelo. Os resultados experimentais mostram uma grande vantagem da técnica de fio quente de superfície em relação a técnica de fio quente paralelo para materiais com condutividade térmica superior a 10 W/mK. O intervalo de tempo considerado no cálculo é bem maior que aquele que seria utilizado na técnica de fio quente paralelo, obtendo-se assim resultados mais precisos e confiáveis.Thermal conductivity is one of the most important physical properties of a material. However, its experimental evaluation may presents some specific troubles, and high precision in the determination of the factors involved in its calculation is required. Specifically for refractory materials, the experimental technique employed worldwide for thermal conductivity calculations is the hot wire technique, in which the thermal conductivity is calculated starting from the temperature transient generated by an ideal, infinitely thin and long heat source embedded in an infinite surrounding material. In this work comparisons

  13. Humeral Supracondylar Fractures in Children: A Novel Technique of Lateral External Fixation and Kirschner Wiring.

    Science.gov (United States)

    Kow, R Y; Zamri, A R; Ruben, J K; Jamaluddin, S; Mohd-Nazir, M T

    2016-07-01

    Introduction: Supracondylar fracture of the humerus is the most common fracture around the elbow in children. Pinning with Kirschner wires (K-wires) after open or closed reduction is generally accepted as the primary treatment modality. However, it comes with the risk of persistent instability and if the K-wire is not inserted properly, it may cause displacement and varus deformity. We present our two-year experience with a new technique of lateral external fixation and K-wiring of the humeral supracondylar fracture. Materials and Methods: A total of seven children with irreducible Gartland Type III supracondylar humeral fracture were treated with closed reduction and lateral external fixation and lateral Kirschner wiring. Patients with ipsilateral radial or ulnar fracture, open fracture and presence of neurovascular impairment pre-operatively were excluded. All the patients were followed up at one, three and six weeks and three and six months. The final outcomes were assessed based on Flynn's criteria. Results: All the patients achieved satisfactory outcomes in terms of cosmetic and functional aspects. All patients except one (85.5%) regained excellent and good cosmetic and functional status. One patient (14.3%) sustained pin site infection which resolved with oral antibiotic (Checketts- Otterburn grade 2). There was no neurological deficit involving the ulnar nerve and radial nerve. Conclusion: The introduction of lateral external fixation and lateral percutaneous pinning provide a promising alternative method for the treatment of humeral supracondylar fracture. This study demonstrates that it has satisfactory cosmetic and functional outcomes with no increased risk of complications compared to percutaneous pinning.

  14. Humeral Supracondylar Fractures in Children: A Novel Technique of Lateral External Fixation and Kirschner Wiring

    Directory of Open Access Journals (Sweden)

    Kow RY

    2016-07-01

    Full Text Available Introduction: Supracondylar fracture of the humerus is the most common fracture around the elbow in children. Pinning with Kirschner wires (K-wires after open or closed reduction is generally accepted as the primary treatment modality. However, it comes with the risk of persistent instability and if the K-wire is not inserted properly, it may cause displacement and varus deformity. We present our two-year experience with a new technique of lateral external fixation and K-wiring of the humeral supracondylar fracture. Materials and Methods: A total of seven children with irreducible Gartland Type III supracondylar humeral fracture were treated with closed reduction and lateral external fixation and lateral Kirschner wiring. Patients with ipsilateral radial or ulnar fracture, open fracture and presence of neurovascular impairment pre-operatively were excluded. All the patients were followed up at one, three and six weeks and three and six months. The final outcomes were assessed based on Flynn's criteria. Results: All the patients achieved satisfactory outcomes in terms of cosmetic and functional aspects. All patients except one (85.5% regained excellent and good cosmetic and functional status. One patient (14.3% sustained pin site infection which resolved with oral antibiotic (CheckettsOtterburn grade 2. There was no neurological deficit involving the ulnar nerve and radial nerve. Conclusion: The introduction of lateral external fixation and lateral percutaneous pinning provide a promising alternative method for the treatment of humeral supracondylar fracture. This study demonstrates that it has satisfactory cosmetic and functional outcomes with no increased risk of complications compared to percutaneous pinning.

  15. On Electromagnetic Field-to-Wire Coupling Versus Conducted Injection Techniques

    Science.gov (United States)

    Javor, Ken

    1997-01-01

    Since the inception of conducted injection techniques to model radiated susceptibility/immunity coupling, considerable debate has ensued regarding its validity. This paper affirms the viewpoint of Szentkuti, (1989) builds upon test results of Adams (1992) and Trout (1996), and discusses Perini's theoretical observations (1993, 1995A, 1995B). Analytical and test results are presented which further demonstrate under what specific conditions conducted and radiated techniques can be correlated, and how the work of Adams, Trout, and Perini fits into the general problem of modeling field-to-wire coupling. At frequencies where transmission line and antenna effects are minimal, conducted immunity techniques provide excellent correlation with analytical and empirical predictions of radiated coupling. From a practical standpoint, conducted injection techniques provide realistic coupling at frequencies and amplitude levels that would be uneconomical to achieve with traditional radiated techniques.

  16. Wire-mesh and ultrasound techniques applied for the characterization of gas-liquid slug flow

    Energy Technology Data Exchange (ETDEWEB)

    Ofuchi, Cesar Y.; Sieczkowski, Wytila Chagas; Neves Junior, Flavio; Arruda, Lucia V.R.; Morales, Rigoberto E.M.; Amaral, Carlos E.F.; Silva, Marco J. da [Federal University of Technology of Parana, Curitiba, PR (Brazil)], e-mails: ofuchi@utfpr.edu.br, wytila@utfpr.edu.br, neves@utfpr.edu.br, lvrarruda@utfpr.edu.br, rmorales@utfpr.edu.br, camaral@utfpr.edu.br, mdasilva@utfpr.edu.br

    2010-07-01

    Gas-liquid two-phase flows are found in a broad range of industrial applications, such as chemical, petrochemical and nuclear industries and quite often determine the efficiency and safety of process and plants. Several experimental techniques have been proposed and applied to measure and quantify two-phase flows so far. In this experimental study the wire-mesh sensor and an ultrasound technique are used and comparatively evaluated to study two-phase slug flows in horizontal pipes. The wire-mesh is an imaging technique and thus appropriated for scientific studies while ultrasound-based technique is robust and non-intrusive and hence well suited for industrial applications. Based on the measured raw data it is possible to extract some specific slug flow parameters of interest such as mean void fraction and characteristic frequency. The experiments were performed in the Thermal Sciences Laboratory (LACIT) at UTFPR, Brazil, in which an experimental two-phase flow loop is available. The experimental flow loop comprises a horizontal acrylic pipe of 26 mm diameter and 9 m length. Water and air were used to produce the two phase flow under controlled conditions. The results show good agreement between the techniques. (author)

  17. [Bipolar femoral head replacement combined with tension band wire fixation for intertrochanteric fracture in elderly osteoporotic patients].

    Science.gov (United States)

    Zhang, Hua; Zhang, Jian; Zhou, Aiguo; Jiang, Dianming; Shen, Honglin; Yan, Wenlong

    2013-08-01

    To explore the effectiveness of bipolar femoral head replacement combined with tension band wire fixation for intertrochanteric fracture in elderly osteoporotic patients. Bipolar femoral head replacement combined with tension band wire fixation were used for intertrochanteric fracture in 48 elderly osteoporotic patients between January 2004 and December 2010. Of 48 patients, 15 were male and 33 were female, aged 90-99 years (mean, 94.1 years). All fractures were caused by falling, and pathological fracture was excluded. It was 2-7 days (mean, 4.2 days) from fracture to surgery. According to the Tronzo Evans classification, 25 cases were rated as type IV, 20 cases as type III, and 3 cases as type II. And all of the cases were accompanied with severe osteoporosis and accompanied by more than one medical diseases, and 10 cases had spinal compression fracture. All patients underwent the operation successfully. Six cases died of underlying medical illness within 2 years postoperatively. A total of 39 cases were followed up 2-7 years, averaged 3.1 years. After operation, short-term mental disorders occurred in 9 cases, suspected urinary tract infection in 2 cases, sacral rear bedsore in 1 case, hip pain in 1 case, thigh pain in 1 case, and deep vein thrombosis of affected limb in 1 case. All the incisions healed by first intension, and X-ray film showed bone union in all cases; no complications of bone osteolysis, prosthesis loosening, subsidence, rupture, and heterotopic ossification occured postoperatively. No case needed revision. According to the Harris score system, the results were excellent in 5 cases, good in 28 cases, fair in 5 cases, and poor in 1 case, with an excellent and good rate of 84.6%; the score at 2 years was significantly higher than that at 6 weeks (t = -14.79, P = 0.00). The physical health score and mental health score of SF-12 at 2 years postoperatively were significantly higher than those at 6 weeks postoperatively (P load bearing, pain

  18. Cu/Cu{sub 2}O/CuO nanoparticles: Novel synthesis by exploding wire technique and extensive characterization

    Energy Technology Data Exchange (ETDEWEB)

    Sahai, Anshuman [Department of Physics and Materials Science and Engineering, Jaypee Institute of Information Technology, A-10, Sector-62, Noida 201307 (India); Goswami, Navendu, E-mail: navendugoswami@gmail.com [Department of Physics and Materials Science and Engineering, Jaypee Institute of Information Technology, A-10, Sector-62, Noida 201307 (India); Kaushik, S.D. [UGC-DAE-Consortium for Scientific Research Mumbai Centre, R5 Shed, BARC, Mumbai 400085 (India); Tripathi, Shilpa [UGC-DAE Consortium for Scientific Research, Indore, M.P. (India)

    2016-12-30

    Highlights: The salient features of this research article are following: • Mixed phase synthesis of Cu/Cu{sub 2}O/CuO nanoparticles prepared by Exploding Wire Technique (EWT). • Predominant Cu/Cu{sub 2}O phases along with minor CuO phase revealed through XRD, TEM, Raman, FTIR, UV–Visible and PL analyses. • XPS analysis provided direct evidences of Cu{sup 2+} and Cu{sup +} along with O deficiency for prepared nanoparticles. • Room temperature weak ferromagnetic behaviour was demonstrated for Cu/Cu{sub 2}O/CuO nanoparticles. - Abstract: In this article, we explore potential of Exploding Wire Technique (EWT) to synthesize the copper nanoparticles using the copper metal in a plate and wire geometry. Rietveld refinement of X-ray diffraction (XRD) pattern of prepared material indicates presence of mixed phases of copper (Cu) and copper oxide (Cu{sub 2}O). Agglomerates of copper and copper oxide comprised of ∼20 nm average size nanoparticles observed through high resolution transmission electron microscope (HRTEM) and energy dispersive x-ray (EDX) spectroscopy. Micro-Raman (μR) and Fourier transform infrared (FTIR) spectroscopies of prepared nanoparticles reveal existence of additional minority CuO phase, not determined earlier through XRD and TEM analysis. μR investigations vividly reveal cubic Cu{sub 2}O and monoclinic CuO phases based on the difference of space group symmetries. In good agreement with μRaman analysis, FTIR stretching modes corresponding to Cu{sub 2}-O and Cu-O were also distinguished. Investigations of μR and FTIR vibrational modes are in accordance and affirm concurrence of CuO phases besides predominant Cu and Cu{sub 2}O phase. Quantum confinement effects along with increase of band gaps for direct and indirect optical transitions of Cu/Cu{sub 2}O/CuO nanoparticles are reflected through UV–vis (UV–vis) spectroscopy. Photoluminescence (PL) spectroscopy spots the electronic levels of each phase and optical transitions processes

  19. Cu/Cu2O/CuO nanoparticles: Novel synthesis by exploding wire technique and extensive characterization

    International Nuclear Information System (INIS)

    Sahai, Anshuman; Goswami, Navendu; Kaushik, S.D.; Tripathi, Shilpa

    2016-01-01

    Highlights: The salient features of this research article are following: • Mixed phase synthesis of Cu/Cu 2 O/CuO nanoparticles prepared by Exploding Wire Technique (EWT). • Predominant Cu/Cu 2 O phases along with minor CuO phase revealed through XRD, TEM, Raman, FTIR, UV–Visible and PL analyses. • XPS analysis provided direct evidences of Cu 2+ and Cu + along with O deficiency for prepared nanoparticles. • Room temperature weak ferromagnetic behaviour was demonstrated for Cu/Cu 2 O/CuO nanoparticles. - Abstract: In this article, we explore potential of Exploding Wire Technique (EWT) to synthesize the copper nanoparticles using the copper metal in a plate and wire geometry. Rietveld refinement of X-ray diffraction (XRD) pattern of prepared material indicates presence of mixed phases of copper (Cu) and copper oxide (Cu 2 O). Agglomerates of copper and copper oxide comprised of ∼20 nm average size nanoparticles observed through high resolution transmission electron microscope (HRTEM) and energy dispersive x-ray (EDX) spectroscopy. Micro-Raman (μR) and Fourier transform infrared (FTIR) spectroscopies of prepared nanoparticles reveal existence of additional minority CuO phase, not determined earlier through XRD and TEM analysis. μR investigations vividly reveal cubic Cu 2 O and monoclinic CuO phases based on the difference of space group symmetries. In good agreement with μRaman analysis, FTIR stretching modes corresponding to Cu 2 -O and Cu-O were also distinguished. Investigations of μR and FTIR vibrational modes are in accordance and affirm concurrence of CuO phases besides predominant Cu and Cu 2 O phase. Quantum confinement effects along with increase of band gaps for direct and indirect optical transitions of Cu/Cu 2 O/CuO nanoparticles are reflected through UV–vis (UV–vis) spectroscopy. Photoluminescence (PL) spectroscopy spots the electronic levels of each phase and optical transitions processes occurring therein. Iterative X

  20. Controlled antegrade intimal tracking with subintimal balloon inflation as a novel bailout technique for chronic total occlusion after failed intravascular ultrasound-guided parallel wire technique.

    Science.gov (United States)

    Imai, Yuta; Yajima, Junji; Hosaka, Fumitaka

    Failure to cross with a guidewire is the most common reason for failure of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). In cases of CTO PCI with no interventional collaterals, an intravascular ultrasound (IVUS)-guided parallel wire technique is usually the last-resort procedure. Failure of this technique sometimes causes enlarged subintimal space, resulting in procedure failure. We present a successful second attempt at left anterior descending artery CTO PCI with no interventional collaterals. After IVUS-guided parallel wire technique failed with an enlarged subintimal space, successful antegrade wire crossing was achieved using controlled antegrade intimal tracking with balloon inflation in the subintimal space to deflect a second wire. This technique may be useful as a bailout strategy in otherwise-failed CTO PCI with an enlarged subintimal space. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  2. Procedure for Changing an Impella Device while Maintaining Guide Wire Access: A Novel Technique

    Directory of Open Access Journals (Sweden)

    Tigran Khachatryan

    2016-01-01

    Full Text Available We describe a novel technique to exchange an Impella over a guide-wire, preserving the arteriotomy access and to lower the risks of vascular complications. We describe this technique in the context of two interesting cases. The first case is of a young man with myocarditis and cardiogenic shock from a previously undiagnosed systemic lupus erythematous. The second case is of a woman with ST elevation myocardial infarction and cardiogenic shock requiring complex percutaneous intervention. The implantation of Impella CP served as circulatory support in these cases as myocardium recovered but was complicated by access site bleeding. We were able to remove the Impella device while maintaining the access sheath to allow for adequate hemostasis prior to sheath removal. We believe the readers of the journal will find these images and technique interesting and useful in their own practice.

  3. Comparison of Tension-Band Wiring With the Cable Pin System in Patella Fractures: A Randomized Prospective Study.

    Science.gov (United States)

    Tian, Qing-xian; Hai, Yong; Du, Xin-ru; Xu, Zi-yu; Lu, Tie; Shan, Lei; Liu, Yang; Zhou, Jun-lin

    2015-12-01

    To compare the outcome of tension-band wiring (TBW) with the cable pin system (CPS) for transverse fractures of the patella. Randomized prospective study. Academic Level I trauma center. From February 2008 to December 2011, 73 consecutive patients with transverse fractures of the patella were prospectively enrolled in this study. The patients were randomly divided into 2 groups: one group was treated using the CPS, and the other group was treated using the modified TBW. The clinical outcome assessment included analyses of the radiographic images, the modified Hospital for Special Surgery scoring system, and complications. The follow-up time ranged from 12 to 29 months. All fractures healed, with a union rate of 100%. The fracture healing time was significantly shorter in the CPS group (8.51 ± 2.59 weeks, n = 34) compared with the TBW group (11.79 ± 3.04 weeks, n = 39). Postoperative complications in the CPS and TBW groups were observed in 1 and 9 patients, respectively, a difference that was statistically significant. The mean Hospital for Special Surgery score for the CPS group (90.53 ± 5.19 points) was significantly higher than that for the TBW group (81.36 ± 12.71 points). The CPS is a viable option for transverse fractures of the patella and is associated with a shorter healing time, fewer complications, and better function than TBW. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  4. Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures.

    Science.gov (United States)

    Thelen, Simon; Schneppendahl, Johannes; Baumgärtner, Ralf; Eichler, Christian; Koebke, Jürgen; Betsch, Marcel; Hakimi, Mohssen; Windolf, Joachim; Wild, Michael

    2013-02-01

    A bilateral fixed-angle plate was biomechanically compared to the two currently preferred methods of osteosynthesis for transverse patella fractures. It was hypothesized that the new angle-stable implant would provide a secure and sustainable fracture fixation, superior to the established standard techniques. Twenty-one identical patellae made of polyurethane foam (Sawbones(®)), osteotomized to create a transverse two-part fracture, were fixed with modified anterior tension wiring, cannulated lag screws with anterior tension wiring or bilateral polyaxial 2.7-mm fixed-angle plates. The testing protocol consisted of 10,000 repetitive cycles using a non-destructive physiological load between 100 and 300 N at a simulated knee flexion of 60°. All 21 Sawbone(®)-patellae sustained repetitive loading up to 10,000 cycles without failing. The anterior tension wire group displayed significant displacement of the fracture gap (0.7 ± 0.2 mm) during cyclic loading, while both lag screws with tension wiring and bilateral fixed-angle plates showed no fracture gap widening at all (p wiring preserved a constantly reduced fracture gap over 10,000 tensile cycles in contrast to modified anterior tension wiring, which exhibited significant widening of the gap after initial loading. Results of in vitro testing indicate that bilateral fixed-angle plates provide sustainable fixation stability offering a promising new option in the treatment for transverse patella fractures.

  5. Heat transfer monitoring by means of the hot wire technique and finite element analysis software.

    Science.gov (United States)

    Hernández Wong, J; Suarez, V; Guarachi, J; Calderón, A; Rojas-Trigos, J B; Juárez, A G; Marín, E

    2014-01-01

    It is reported the study of the radial heat transfer in a homogeneous and isotropic substance with a heat linear source in its axial axis. For this purpose, the hot wire characterization technique has been used, in order to obtain the temperature distribution as a function of radial distance from the axial axis and time exposure. Also, the solution of the transient heat transport equation for this problem was obtained under appropriate boundary conditions, by means of finite element technique. A comparison between experimental, conventional theoretical model and numerical simulated results is done to demonstrate the utility of the finite element analysis simulation methodology in the investigation of the thermal response of substances. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. The double wire technique: an improved method for treating challenging ureteroileal anastomotic strictures and occlusions.

    Science.gov (United States)

    Thiruchelvam, N; Harrison, M; Page, A C

    2007-02-01

    Up to 10% of patients who undergo ileal conduit urinary diversion may go on to develop ureteroileal anastomotic stenosis (UIAS); this can lead to recurrent urinary tract infections and deterioration in renal function. Classical management has been open revision of the anastomosis. We describe a novel technique that allows balloon dilatation and ureteral stent placement in a retrograde fashion. All patients in this study had undergone radical cystectomy and ileal conduit formation with Wallace type end-to-end refluxing uretero-intestinal anastomosis. After initial retrograde loopogram, a 6F MPA-1 catheter and an 0.035 inch extra stiff guide was passed to the distal ostium. Subsequently, a customised 8F bright tip MPA-1 guiding catheter was advanced over the guide wire which allowed effective splinting of the equipment to facilitate greater control of a second catheter and guide wire combination to access the stenotic or occluded anastomosis. Results show that a total of ten anastomoses were treated; nine anastomoses were successfully treated with a primary retrograde approach with no intra or post-procedural complications. After a mean follow-up of 19 months (5-33 months), as assessed by ascending loopograms, all anastomoses remained open. In conclusion, morbidity of open surgery has resulted in the popularization of endourological techniques in treating anastomotic stenoses. However, key to these endourological techniques is access to the anastomosis; typically, this has been via a percutaneously placed nephrostomy. The ideal route to the anastomosis is via a retrograde approach; we have illustrated a safe and successful novel technique that utilized two guidewires and a guiding catheter, allowing retrograde ureteral access.

  7. USING HOT WIRE TECHNIQUE FOR MEASURING THERMAL CONDUCTIVITY OF INFUSIONS OF ORGANIC AND CONVENTIONAL COFFEE

    Directory of Open Access Journals (Sweden)

    Fernando Gordillo-Delgado

    2016-07-01

    Full Text Available The technique of hot wire, a versatile method of low cost and high accuracy for measuring the thermal conductivity of fluids through the increasing temperature of a wire that is immersed into the liquid and between its ends a potential difference is abruptly applied. Using well-known conductivity liquids: water, ethylene glycol and glycerine, the system was tested and calibrated. In this work, this procedure was used to measure the thermal conductivity of the infusion samples of organic and conventional coffee. The same roast degree of the beans was verified with a colorimeter and the preparation was made by pressing 22g of coffee powder in 110mL of water. The obtained data were subjected to Analysis of Variance (ANOVA and this confirmed that the differences in the thermophysical parameter in the two samples are significant with a confidence level of 95\\%. On this way, it was proved that the thermal conductivity value of the coffee infusion allows differentiate between organic and conventional coffee.

  8. Long-term outcomes of tension band wiring with a single K-wire in Rockwood type IV/V acute acromio-clavicular dislocations: 25 cases.

    Science.gov (United States)

    Lateur, G; Boudissa, M; Rubens-Duval, B; Mader, R; Rouchy, R C; Pailhé, R; Saragaglia, D

    2016-09-01

    Our objective was to evaluate the long-term functional and radiological outcomes of tension band wiring with a single K-wire for acute Rockwood types IV and V acromio-clavicular dislocation (ACD). Single-centre cross-sectional non-randomised observational cohort study of 25 shoulders treated surgically between January 2002 and December 2004, in 25 patients, 23 males and 2 females, with a mean age of 35±11years (24-46). The evaluation criteria were the absolute and weighted Constant scores, QuickDASH score, subjective shoulder value (SSV), visual analogue scale (VAS) pain score at rest and during activities, and radiographic features in clinically symptomatic patients. Mean values were as follows: follow-up, 150±17months (133-167); absolute Constant score, 88±17 (71-105); weighted Constant score, 92.5±12.5 (80-105); QuickDASH, 15.5±7 (8.5-22.5); SSV, 88±17% (71-105); VAS pain score at rest, 0.2±0.7 (0-0.9); and VAS pain score while active, 1.4±2.3 (0-3.7). The weighted Constant score was less than 70% in only 8% of patients. Of the 17 patients for whom radiographs were obtained, 8 had acromio-clavicular osteoarthritis. Mean coraco-clavicular distance was 12.3±4.3mm (8-16.6) and mean acromio-clavicular distance was 5±5mm (0-10). The recurrence rate was 8%. Tension band wiring with a single K-wire for acute acromio-clavicular dislocation reliably provides good long-term functional outcomes. Recurrences are uncommon and few patients experience symptoms (8%). IV, retrospective study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Radiographic comparison of apical root resorption after orthodontic treatment between bidimensional and Roth straight-wire techniques.

    Science.gov (United States)

    Zawawi, Khalid H; Malki, Ghadah A

    2014-10-01

    The aim of this study was to compare the amount of root resorption after orthodontic treatment between the bidimensional and the Roth straight-wire techniques. Another objective was to compare the amount of root resorption in the whole sample studied and record the prevalence of root resorption. The sample consisted of 40 patients (age ranged between 11 and 18 years) with Angle Class II division 1 malocclusions, treated nonextraction. Twenty patients were treated with bidimensional technique and 20 with a 0.018-inch Roth straight-wire technique. Root lengths of the maxillary incisors were measured on pre- and post-treatment periapical radiographs. The results demonstrated that the bidimensional and Roth straight-wire groups showed significant root resorption after treatment, 1.11 (0.17) and 0.86 (0.05), respectively, P straight-wire groups, there was no significant difference between the mean change from pre- to post-treatment between bidimensional group (mean = 1.00 ± 1.34) and Roth straight-wire group (mean = 0.88 ± 0.86), P = 0.63. Considering the whole sample, there was no root resoprtion in 32.5% of the analysed teeth. There was only mild resorption in 56.2%, moderate in 8.8% and severe in only 2.5% of the teeth. Treatment with the bidimensional technique did not produce an increase in the amount of root resorption. The prevalence and amount of root resorption was similar between bidimensional and Roth straight-wire techniques.

  10. Differential Interferometry Techniques on L-Band Data Employed for ...

    African Journals Online (AJOL)

    On the other hand, satellite remote sensing data provides a synoptic view of an area and the repeat image acquisition strategy implies that the long-term monitoring of surface deformation is a possibility. This paper investigates the use of L-band ALOS PALSAR data for the detection and monitoring of surface subsidence ...

  11. Comparison of two percutaneous tracheostomy techniques, guide wire dilating forceps and Ciaglia Blue Rhino: a sequential cohort study.

    NARCIS (Netherlands)

    Fikkers, B.G.; Staatsen, M; Lardenoije, S.G.; Hoogen, F.J.A. van den; Hoeven, J.G. van der

    2004-01-01

    INTRODUCTION: To evaluate and compare the peri-operative and postoperative complications of the two most frequently used percutaneous tracheostomy techniques, namely guide wire dilating forceps (GWDF) and Ciaglia Blue Rhino (CBR). METHODS: A sequential cohort study with comparison of short-term and

  12. Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones.

    Science.gov (United States)

    Gruszka, Dominik; Arand, Charlotte; Greenfield, Julia; Nowak, Tobias E; Kuechle, Raphael; Kuhn, Sebastian; Rommens, Pol M

    2017-12-01

    Tension band wiring (TBW) used for olecranon fractures is afflicted with a high rate of complications. The aim of this study was to compare the stability of the TBW versus an alternative, novel low-profile olecranon tension plate (OTP) with angular stable screws in a simulated complex fracture model. Nine fresh-frozen pairs of cadaver proximal ulnae with an oblique osteotomy and an additional wedge fragment simulating an unstable fracture were tested. The TBW and OTP were implanted pairwise. The elbow motion was simulated in a single-muscle model and ranged from full extension to 90° of flexion. The pulling force of the triceps tendon ranged from 50 to 200 N. The displacement of the fracture fragments was measured with a video motion analysis system over 304 cycles. Data were assessed statistically using the Wilcoxon signed-rank test. The cyclic loading tests showed mean loosening of the fracture fragments at the articular surface of 0.56 mm using TBW (SD 0.65) and 0.15 mm for OTP (SD 0.39). There was no statistical significance in loosening between the two constructs (p = 0.31). No plate breakage or screw loosening occurred. The low-profile OTP, using the principles of pre-tensioning, lag, cortical, and angular stable screws together, demonstrated similar stability after olecranon fracture fixation when compared with the TBW technique and a lag screw in the olecranon fracture model with a third wedge fragment.

  13. Societal costs in displaced transverse olecranon fractures: using decision analysis tools to find the most cost-effective strategy between tension band wiring and locked plating.

    Science.gov (United States)

    Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William

    2017-11-01

    Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Wiring Techniques for the Fixation of Trochanteric Fragments during Bipolar Hemiarthroplasty for Femoral Intertrochanteric Fracture: Clinical Study and Technical Note.

    Science.gov (United States)

    Lee, Joong-Myung; Cho, Yongsuk; Kim, Junhyun; Kim, Dong-Won

    2017-03-01

    Femoral intertrochanteric fractures are common in the elderly. Appropriate surgical fixation of trochanteric fracture fragments can restore normal anatomical structure and ambulation, and can aid in the recovery of biomechanical function of the hip. We evaluated clinical outcomes of bipolar hemiarthroplasty using a wiring technique for trochanteric fracture fragment fixation. From September 2006 to February 2015, a total of 260 cases underwent simultaneous bipolar hemiarthroplasty and wire fixation. A total of 65 patients (69 hips) with an average age of 78 years and more than one year of follow-up was included in the study. Using pre-, postoperative and follow-up radiograms, we evaluated wire fixation failure and also assessed changes in walking ability. Loosening or osteolysis around the stem was not observed; however, we did observe bone growth around the stem (54 cases), cortical hypertrophy (6 cases), a wide range of sclerotic lines but no stem subsidence (1 case), wire breakage (9 cases), and fracture fragment migration with no significant functional deficiency (2 cases). Our study showed that additional wiring for trochanteric fracture fragment fixation following bipolar hemiarthroplasty can help restore normal anatomy. The added stability results in faster rehabilitation, and good clinical and radiographic outcomes. We recommend this procedure in this type of fracture.

  15. Wavelength influence in sub-pixel temperature retrieval using the dual-band technique

    Directory of Open Access Journals (Sweden)

    M. F. Buongiorno

    2006-06-01

    Full Text Available The thermal model proposed by Crisp and Baloga (1990 for active lava flows considers thermal flux as a function of the fractional area of two thermally distinct radiant surfaces. In this model, the larger surface area corresponds to the cooler crust of the flow and the other, much smaller to fractures in the crust. These cracks temperature is much higher than the crust one and approaches the temperature of the molten or plastic interior flow. The dual-band method needs two distinct SWIR (short wave infrared bands to formulate a two equations system from the simultaneous solution of the Planck equation in each band. The system solutions consist in the crust temperature and the fractional area of the hot component. The dual band technique originally builds on data acquired by sensors (such as Landsat TM with two SWIR bands only. The use of hyperspectral imaging spectrometers allows us to test the dual-band technique using different wavelengths in the SWIR range of the spectrum. DAIS 7915 is equipped with 40 bands into the range 1.54-2.49 nm which represent potential input in dual band calculation. This study aims to compare results derived by inserting assorted couples of wavelengths into the equation system. The analysis of these data provides useful information on dual-band technique accuracy.

  16. Rigid Sternal Fixation Versus Modified Wire Technique for Poststernotomy Closures: A Retrospective Cost Analysis.

    Science.gov (United States)

    Park, Jiwon Sarah; Kuo, Jennifer H; Young, J Nilas; Wong, Michael S

    2017-05-01

    Rigid sternal fixation (RSF) has been shown to reduce sternal wound complications in high-risk patients. However, the higher initial cost continues to deter its use. This study evaluates the cost of caring for high-risk sternotomy patients who underwent RSF compared with those who underwent sternal closure with a modified wire technique (MWT). A retrospective single institution review of high-risk patients who underwent MWT (n = 45) and RSF (n = 30) for primary sternal closure from 2006 to 2009 was conducted. Total hospital cost, revenue, and net cost associated with surgery and subsequent care were analyzed. Overall rates of wound dehiscence and wound infections (superficial and deep) were higher in MWT patients (n = 14, 13, and 7, respectively) than RSF patients (n = 3, 2, and 0, respectively; P costs associated with their operative hospitalization, outpatient care, and home health than RSF patients (total net loss: US $41,436 ± 7327 vs US $10,612 ± 4,258; P = 0.034). In high-risk patients, RSF is associated with lower rates of infections, including the "never event" mediastinitis, compared with MWT. Moreover, despite the initial higher cost, RSF affords an overall lower cost of care compared with MWT in patients at high-risk for developing sternal complications.

  17. Localization of intraductal mass through the ostium of the duct using wire guided ductography technique

    International Nuclear Information System (INIS)

    Aslam, M.

    2014-01-01

    To localize intraductal mass (Papilloma) before surgery Materials Guide wire 10-15 cm length of 2/3-0 Prolene/Surgipro Plastic 26G to 20G I/V cannulas Kopans breast lesion localization hook wire Disposable syringe heaving 2ml non-ionic contrast High intensity light and magnified glass. Methods: Prepare patient in sitting or lying position adjust high intensity light clean the nipple with antiseptic lotion. Elicit the discharge with gentle periareolar pressure or ask the patient to bring the discharge. If the opening with discharge is not clearly visualize use magnified glass or loop. Slowly inserted the wire into the duct orifice, it should pass freely into the duct. Introduce the 26G I/V plastic cannula coaxially over the guide wire and remove the guide wire. Gently inject 0.2-0.4 ml contrast, remove and the syringe and apply stopper. The cannula stopper assembly is secured to the breast with tape. Magnified craniocaudal view of the breast is taken, the 26G cannula removed and bigger length 22/20G cannula gradually passed over the guide wire according to distance of lesion from the ostium. Intraductal mass location is verified the hook wire is replaced with guide wire, the position of hook confirmed by mammographic film. The wire is cut 2cms from the nipple and pt. send to operation theater Results:Hook localization has been successfully carried out in six patients. Conclusion:This is a new method of localization of intraductal mass it enables the surgeon to do microductectomy with minimal cosmetic effects to the breast. (author)

  18. Gain-clamping techniques in two-stage double-pass L-band EDFA

    Indian Academy of Sciences (India)

    Two designs of long-wavelength band erbium-doped fiber amplifier (L-band EDFA) for gain clamping in double-pass systems are demonstrated and compared. The first design is based on ring laser technique where a backward amplified spontaneous emission (ASE) from the second stage is routed into the feedback loop ...

  19. A New Technique for Superselective Catheterization of Arteries: Preshaping of a Micro-Guide Wire into a Shepherd's Hook Form

    International Nuclear Information System (INIS)

    Baek, Jee Hyun; Chung; Jin Wook; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung

    2007-01-01

    We wanted to introduce a new technique for superselective catheterization of arteries with preshaping of a micro-guide wire into a shepherd's hook form, and this is useful for superselection of small arteries branching at an acute angle from a large parent artery for the treatment of tumors and hemorrhages. We developed a superselective catheterization technique by using preshaping of a micro-guide wire into a shepherd's hook form. We encountered six patients in our practice for whom we failed to catheterize the small tumor-feeding arteries that branched at an acute angle from wide parent arteries during chemoembolization of hepatocellular carcinoma; the parent arteries were the right inferior phrenic artery (n = 4) and the left gastric artery (n = 1) from the celiac axis with celiac stenosis due to compression by the median arcuate ligament and the proper hepatic artery from the gastroduodenal artery (n = 1) in a patient who had celiac axis occlusion with collateral circulation via the pancreaticoduodenal arcade from the superior mesenteric artery. In these consecutive six patients, we tested the usefulness of this new technique with employing preshaping of a micro-guide wire into a shepherd's hook form for superselective catheterization of targeted vessels. The target arteries were successfully catheterized and satisfactory transcatheter arterial chemoembolization was performed in all six patients. There were no significant complications such as arterial dissection. We developed a technique that is effective for superselection of vessels with preshaping of micro-guide wire into a shepherd's hook hook form, and we successfully applied it during chemoembolization of hepatocellular carcinoma. This technique can be useful for superselection of small arteries that branch from a large parent artery at acute angles for the treatment of tumors and hemorrhages

  20. Stent induced gastric wall erosion and endoscopic retrieval of nonadjustable gastric band: a new technique.

    Science.gov (United States)

    Wilson, Todd D; Miller, Nathan; Brown, Nicholas; Snyder, Brad E; Wilson, Erik B

    2013-05-01

    In gastrointestinal surgery, specifically in bariatric surgery, there are many types of fixed bands used for restriction and there are a multitude reasons that might eventually be an impetus for the removal of those bands. Bands consisting of Marlex or non silastic materials can be extremely difficult to remove. Intraoperative complications removing fixed bands include the difficulty in locating the band, inability to remove all of the band, and damage to surrounding structures including gastrotomies. Removal of eroded bands endoscopically may pose less risk. Potentially, forced erosion may be an easier modality than surgery, allowing revision without having to deal with the actual band at the time of definitive revision surgery. A retrospective case series developed from a university single institution bariatric practice setting was utilized. Endpoints for the study include success of band removal, complications, length of time the stent was present, and the type of stent. A total of 15 consecutive cases utilizing endoscopic stenting to actively induce fixed gastric band erosion for subsequent endoscopic removal were reviewed. There was an 87 % success rate in complete band removal with partial removal of the remaining bands that resolved the patient's symptoms. A complication rate of 27 % was recorded among the 15 patients, consisting of pain and/or nausea and vomiting. The mean time period of the placement of the stent prior to removal or attempted removal was 16.3 days. Endoscopic forced erosion of fixed gastric bands is feasible, safe, and may offer an advantage over laparoscopic removal. This technique is especially applicable for gastric obstruction from fixed bands, prior to large and definitive revision surgeries, or anticipated hostile anatomy that might preclude an abdominal operation altogether.

  1. Telescopic catheter-in-long sheath and parallel to a stiff guide wire technique for complex pulmonary artery anatomy.

    Science.gov (United States)

    Butera, Gianfranco; Hassan, Eman; MacDonald, Simon T

    2012-10-01

    Selective catheterization and procedures in pulmonary arteries may be very challenging. We developed a technique in which an extra-stiff guide wire was placed in a pulmonary artery. Across it a long sheath was placed proximally or controlateral to the lesion to be treated. An angiographic catheter was then placed parallel to the guide wire in a telescopic way within the long sheath. This system facilitated greater stability, allowing fine tuning of catheter position to reach and treat the target lesion. Here, we present five cases in whom this technique was used; a patient with multiple arteriovenous fistulas in a difficult to reach area and four subjects with complex pulmonary artery stenoses. Copyright © 2012 Wiley Periodicals, Inc.

  2. Thermal stability of the optical band gap and structural order in hot-wire-deposited amorphous silicon

    CSIR Research Space (South Africa)

    Arendse, CJ

    2009-01-01

    Full Text Available and that the structural disorder increases upon annealing. The increase in the structural disorder results in a broadening of the valence and conduction band tails, thereby pinning the valence and conduction band edges closer together, resulting in a decrease...

  3. Calculating modes of quantum wire systems using a finite difference technique

    Directory of Open Access Journals (Sweden)

    T Mardani

    2013-03-01

    Full Text Available  In this paper, the Schrodinger equation for a quantum wire is solved using a finite difference approach. A new aspect in this work is plotting wave function on cross section of rectangular cross-sectional wire in two dimensions, periodically. It is found that the correct eigen energies occur when wave functions have a complete symmetry. If the value of eigen energy has a small increase or decrease in neighborhood of the correct energy the symmetry will be destroyed and aperturbation value at the first of wave function will be observed. In addition, the demand on computer memory varies linearly with the size of the system under investigation.

  4. Simple preconditioning technique: empirical formula for condition number reduction at a junction of several wires

    CSIR Research Space (South Africa)

    Lysko, AA

    2011-08-01

    Full Text Available The condition number for a method-of-moments’ impedance matrix resulting from a junction of several wires is frequency dependant and can be minimized at a given frequency using several approaches. An empirical formula for an optimum, condition...

  5. Fluorescence from metallic silver and iron nanoparticles prepared by exploding wire technique

    OpenAIRE

    Alqudami, Abdullah; Annapoorni, S.

    2006-01-01

    The observation of intense visible fluorescence from silver and iron nanoparticles in different solution phases and surface capping is reported here. Metallic silver and iron nanoparticles were obtained by exploding pure silver and iron wires in pure water. Bovine serum albumin protein adsorption on the silver nanoparticles showed an enhanced fluorescence. The presence of poly-vinyl pyrrolidone polymer in the exploding medium resulted in a stabilized growth of iron nanoparticles with enhanced...

  6. Numerical and experimental determination of the minimum and maximum measuring times for the hot wire parallel technique

    Directory of Open Access Journals (Sweden)

    Santos W. N. dos

    2003-01-01

    Full Text Available The hot wire technique is considered to be an effective and accurate means of determining the thermal conductivity of ceramic materials. However, specifically for materials of high thermal diffusivity, the appropriate time interval to be considered in calculations is a decisive factor for getting accurate and consistent results. In this work, a numerical simulation model is proposed with the aim of determining the minimum and maximum measuring time for the hot wire parallel technique. The temperature profile generated by this model is in excellent agreement with that one experimentally obtained by this technique, where thermal conductivity, thermal diffusivity and specific heat are simultaneously determined from the same experimental temperature transient. Eighteen different specimens of refractory materials and polymers, with thermal diffusivities ranging from 1x10-7 to 70x10-7 m²/s, in shape of rectangular parallelepipeds, and with different dimensions were employed in the experimental programme. An empirical equation relating minimum and maximum measuring times and the thermal diffusivity of the sample is also obtained.

  7. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    Science.gov (United States)

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Technique for determination of elastic limit of micron band-thick amorphous

    International Nuclear Information System (INIS)

    Zakharov, E.K.; Pol'dyaeva, G.P.; Tret'yakov, B.N.

    1984-01-01

    A method is suggested to determine the elastic limit of micron-thick amorphous band under bending. The elastic limit is determined by bending an amorphous band sample around a series of cylindrical mandrels of gradually decreasing radius. Experimental data on measuring the elastic limit of some amorphous iron base alloys according to the suggested technique are presented. The elastic limit of amorphous alloys is shown to lie in the 3140-4110 MPa range depending on chemical composition, which is about 2-2.5 times higher as compared to high-strength crystal alloys

  9. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  10. Deposition of gold nanoparticle films using spray pyrolysis technique: Tunability of SPR band by electric field

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Neetesh; Komarala, Vamsi K.; Dutta, Viresh [Photovoltaic Laboratory, Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi-110016 (India)

    2012-10-15

    Gold nanoparticle films are prepared using a simple inexpensive spray pyrolysis technique. X-ray as well as TEM diffraction patterns revealed pure cubic structure. The effect of gold nanoparticle concentration on surface plasmon resonance (SPR) band position and bandwidth are investigated for varying spray solution volume. The tunability of SPR band position and bandwidth using an electric field, by applying a voltage (up to 2000 V) to the nozzle, has been demonstrated. The reduced full width at half maximum and blue shift in the SPR band position are observed with {Delta}{lambda}{sub FW} {proportional_to} 55 nm and {Delta}{lambda}{sub P} {proportional_to} 40 nm for the applied voltage of 2 kV. (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. Application of slip-band visualization technique to tensile analysis of laser-welded aluminum alloy

    Science.gov (United States)

    Muchiar, -; Yoshida, Sanichiro J.; Widiastuti, Rini; Kusnowo, A.; Takahashi, Kunimitsu; Sato, Shunichi

    1997-03-01

    Recently we have developed a new optical interferometric technique capable of visualizing slip band occurring in a deforming solid-state object. In this work we applied this technique to a tensile analysis of laser-welded aluminum plate samples, and successfully revealed stress concentration that shows strong relationships with the tensile strength and the fracture mechanism. We believe that this method is a new, convenient way to analyze the deformation characteristics of welded objects and evaluate the quality of welding. The analysis has been made for several types of aluminum alloys under various welding conditions, and has shown the following general results. When the penetration is deep, a slip band starts appearing at the fusion zone in an early stage of the elastic region of the strain-stress curve and stays there till the sample fractures at that point. When the penetration is shallow, a slip band appears only after the yield point and moves vigorously over the whole surface of the sample till a late stage of plastic deformation when the slip band stays at the fusion zone where the sample eventually fractures. When the penetration depth is medium, some intermediate situation of the above two extreme cases is observed.

  12. Technique for preparation of transmission electron microscope specimens from wire samples of Al and Al-Al2O3 alloys

    DEFF Research Database (Denmark)

    Lindbo, Jørgen

    1966-01-01

    A technique for thinning 1 mm wire samples of aluminium and aluminium-alumina alloys for transmission electron microscopy is described. The essential feature of the technique, which involves spark machining and electropolishing in a polytetrafluoroethylene holder followed by chemical polishing, i...

  13. Tension Band Wiring Is As Effective As A Compression Screw In A Neglected, Medial Maleolus Non-Union: A Case-Based Discussion & Literature Review.

    Science.gov (United States)

    John, Rakesh; Dhillon, Mandeep Singh; Khurana, Ankit; Aggarwal, Sameer; Kumar, Prasoon

    2017-01-01

    Isolated, neglected medial malleolus nonunion cases are a rare entity in orthopedic literature. All studies (except one) have described the use of compression screws (with or without plates) for medial malleolar nonunion management. In acute fractures, tension band wiring (TBW) has shown excellent results both in biomechanical and in clinical studies. On the contrary, it has seldom been used in nonunion or in neglected cases. We describe a 6-month-old neglected medial malleolus gap nonunion case who presented with progressive pain and limp. TBW with a monoblock, inlay, tricortical, and iliac crest bone graft for the defect was performed. The fracture united within 12 weeks and patient went back to his normal work routine; on the latest follow-up at 3 years, the patient was asymptomatic with no clinicoradiologic signs of secondary osteoarthritis of the ankle joint. TBW may be better than screw fixation in the management of medial malleolus nonunion as it is technically straightforward and cost-effective, can provide equal or more compression than a screw; it does not damage the sandwiched inlay bone graft, and the amount of compression is surgeon-controlled. It is also more suitable for fractures with small distal fragments and/or osteoporosis.

  14. Improved synthetic aperture focusing technique results of thick concrete specimens through frequency banding

    Science.gov (United States)

    Clayton, Dwight; Barker, Alan; Albright, Austin; Santos-Villalobos, Hector

    2016-02-01

    A multitude of concrete-based structures are typically part of a light water reactor (LWR) plant to provide the foundation, support, shielding, and containment functions. This use has made its long-term performance crucial for the safe operation of commercial nuclear power plants (NPPs). Extending reactor life to 60 years and beyond will likely increase susceptibility and severity of known forms of degradation. We seek to improve and extend the usefulness of results produced using the synthetic aperture focusing technique (SAFT) on ultrasonic data collected from thick, complex concrete structures such as in NPPs. Towards these goals, we apply the time-frequency technique of wavelet packet decomposition and reconstruction using a mother wavelet that possesses the exact reconstruction property. However, instead of analyzing the coefficients of each decomposition node, we select and reconstruct specific nodes based on the frequency band it contains to produce a frequency band specific time-series representation. SAFT is then applied to these frequency specific reconstructions allowing SAFT to be used to visualize the reflectivity of a frequency band and that band's interaction with the contents of the concrete structure. Specially designed and fabricated test specimens can provide realistic flaws that are similar to actual flaws in terms of how they interact with a particular NDE technique. Artificial test blocks allow the isolation of certain testing problems as well as the variation of certain parameters. Because conditions in the laboratory are controlled, the number of unknown variables can be decreased, making it possible to focus on specific aspects, investigate them in detail, and gain further information on the capabilities and limitations of each method. To minimize artifacts caused by boundary effects, the dimensions of the specimens should not be too compact. In this paper, we apply this enhanced SAFT technique to a 2.134 m × 2.134 m × 1.016 m concrete

  15. New measurement technique for turbulent flow as a replacement for hot-wire anemometry

    Science.gov (United States)

    Puczylowski, Jaroslaw; Hölling, Michael; Peinke, Joachim

    2011-11-01

    We present latest developments of the 2d-Laser Cantilever Anemometer (2d-LCA), a sensor, which has been developed for highly resolved measurements of turbulent flows. Its measuring principle allows for high temporal resolutions of beyond 50kHz at spatial scales in sub millimeter range. This performance is achieved by measuring the deformation of a tiny cantilever via laser pointer, which experiences drag forces caused by the flow. The cantilever features two deformation modes, i.e. bending and twisting, whereas the latter occurs only for oblique inflow. Thus the sensor is capable of measuring two velocity components. Latest developments focus on the design of the cantilever. For example, an additional structure for a better sensitivity towards cross winds and an improved reflection pad were realized. Further improvements concern the laser beam guiding within the sensor. Beside this we are in the process of setting up advanced electronics and new types of PSD-elements with the goal of increasing the sensitivity. Comparison measurements between the re-designed 2d-LCA and older versions were performed and showed improvements relating signal quality and reliability. Further measurements in turbulent flow with an x-wire as a reference confirmed the ability of the new sensor to carry out measurements at comparable high resolutions.

  16. Wire Roughness Assessment of 0.016'' × 0.022'' the Technique Lingual Orthodontics.

    Science.gov (United States)

    Facchini, Fátima Mm; Filho, Mario Vedovello; Vedovello, Silvia As; Cotrim, Flávio A; Cotrim-Ferreira, Andrຟa; Tubel, Carlos Am

    2017-04-01

    To evaluate the difference in surface roughness of stainless steel archwires of different commercial brands used in lingual orthodontics. Precontoured arches measuring 0.016'' × 0.022'' were selected of the following brands: Tecnident, Adenta, G&H, Highland Metals Inc., Ormco, Incognito, and Ebraces. Quantitative evaluation of the surface roughness of archwires was performed by means of an atomic force microscope in contact mode. Three surface readouts were taken of each sample, analyzing areas of 20 × 20 μm. Each scan of the samples produced a readout of 512 lines, generating three-dimensional images of the wires. The analysis of variance statistical test was applied to prove significant variables (p > 0.05), with H 0 being rejected and H 1 accepted. The Incognito brand showed the lowest surface roughness. The archwires of brands Adenta, Tecnident, Highland, and Ormco showed similar values among them, and all close to these obtained by the Incognito brand. The archwires of the Ebraces brand showed the highest surface roughness, with values being close to those of the G&H Brand. There was a statistical difference in surface roughness of orthodontic archwires among the brands studied. Companies should pay attention to the quality control of their materials, as these may directly affect the quality of orthodontic treatment.

  17. Isolated olecranon fractures in children affected by osteogenesis imperfecta type I treated with single screw or tension band wiring system: Outcomes and pitfalls in relation to bone mineral density.

    Science.gov (United States)

    Persiani, Pietro; Ranaldi, Filippo M; Graci, Jole; De Cristo, Claudia; Zambrano, Anna; D'Eufemia, Patrizia; Martini, Lorena; Villani, Ciro

    2017-05-01

    The purpose of this study is to compare the results of 2 techniques, tension band wiring (TBW) and fixation with screws, in olecranon fractures in children affected with osteogenesis imperfecta (OI) type I. Between 2010 and 2014, 21 olecranon fractures in 18 children with OI (average age: 12 years old) were treated surgically. Ten patients were treated with the screw fixation and 11 with TBW. A total of 65% of olecranon fractures occurred as a result of a spontaneous avulsion of the olecranon during the contraction of the triceps muscle. The average follow-up was 36 months. Among the children treated with 1 screw, 5 patients needed a surgical revision with TBW due to a mobilization of the screw. In this group, the satisfactory results were 50%. In patients treated with TBW, the satisfactory results were 100% of the cases. The average Z-score, the last one recorded in the patients before the trauma, was -2.53 in patients treated with screw fixation and -2.04 in those treated with TBW. TBW represents the safest surgical treatment for patients suffering from OI type I, as it helps to prevent the rigidity of the elbow through an earlier recovery of the range of motion, and there was no loosening of the implant. In analyzing the average Z-score before any fracture, the fixation with screws has an increased risk of failure in combination with low bone mineral density.

  18. Performance Enhancement in L-Band Edfa Through Dual Stage Technique

    Directory of Open Access Journals (Sweden)

    S. W. Harun and H. Ahmad

    2012-10-01

    Full Text Available An experiment on gain enhancement in the long wavelength band erbium doped fiber amplifier (L-band EDFA is demonstrated. It uses a dual stage technique with dual forward pumping scheme. Compared to a conventional single stage amplifier, the small signal gain for 1580nm signal can be improved by 5.5dB without paying much noise figure penalty. The corresponding noise figure penalty was 0.3dB due to the insertion loss of the optical isolator. The optimum pump power ratio for the first pump is experimentally determined to be 33%. The maximum gain improvement of 8.3dB was obtained at a signal wavelength of 1568nm while signal and total pump powers were fixed at -30dBm and 92mW, respectively. The employment of dual stage amplifier system seems to play an important role in the development of practical L-band EDFA from the perspective of economical usage of pump power.Key Words:  erbium doped fibre; optical amplifier; L-band EDFA; dual stage EDFA; amplified spontaneous emission

  19. Improving synthetic aperture focusing technique for thick concrete specimens via frequency banding

    Science.gov (United States)

    Clayton, Dwight A.

    2016-04-01

    A multitude of concrete-based structures are typically part of a light water reactor (LWR) plant to provide the foundation, support, shielding, and containment functions. This use has made its long-term performance crucial for the safe operation of commercial nuclear power plants (NPPs). Extending reactor life to 60 years and beyond will likely increase susceptibility and severity of known forms of degradation. While standard Synthetic Aperture Focusing Technique (SAFT) is adequate for many defects with shallow concrete cover, some defects located under deep concrete cover are not easily identified using the standard SAFT. For many defects, particularly defects under deep cover, the use of frequency banded SAFT improves the detectability over standard SAFT. In addition to the improved detectability, the frequency banded SAFT also provides improved scan depth resolution that can be important in determining the suitability of a particular structure to perform its designed safety function. Specially designed and fabricated test specimens can provide realistic flaws that are similar to actual flaws in terms of how they interact with a particular NDE technique. Because conditions in the laboratory are controlled, the number of unknown variables can be decreased, making it possible to focus on specific aspects, investigate them in detail, and gain further information on the capabilities and limitations of each method. To validate the advantages of frequency banded SAFT on thick concrete, a 2.134 m x 2.134 m x 1.016 m concrete test specimen with twenty deliberately embedded defects was fabricated.

  20. The Development of Layered Photonic Band Gap Structures Using a Micro-Transfer Molding Technique

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, Kevin Jerome [Iowa State Univ., Ames, IA (United States)

    2001-01-01

    Photonic band gap (PBG) crystals are periodic dielectric structures that manipulate electromagnetic radiation in a manner similar to semiconductor devices manipulating electrons. Whereas a semiconductor material exhibits an electronic band gap in which electrons cannot exist, similarly, a photonic crystal containing a photonic band gap does not allow the propagation of specific frequencies of electromagnetic radiation. This phenomenon results from the destructive Bragg diffraction interference that a wave propagating at a specific frequency will experience because of the periodic change in dielectric permitivity. This gives rise to a variety of optical applications for improving the efficiency and effectiveness of opto-electronic devices. These applications are reviewed later. Several methods are currently used to fabricate photonic crystals, which are also discussed in detail. This research involves a layer-by-layer micro-transfer molding ({mu}TM) and stacking method to create three-dimensional FCC structures of epoxy or titania. The structures, once reduced significantly in size can be infiltrated with an organic gain media and stacked on a semiconductor to improve the efficiency of an electronically pumped light-emitting diode. Photonic band gap structures have been proven to effectively create a band gap for certain frequencies of electro-magnetic radiation in the microwave and near-infrared ranges. The objective of this research project was originally two-fold: to fabricate a three dimensional (3-D) structure of a size scaled to prohibit electromagnetic propagation within the visible wavelength range, and then to characterize that structure using laser dye emission spectra. As a master mold has not yet been developed for the micro transfer molding technique in the visible range, the research was limited to scaling down the length scale as much as possible with the current available technology and characterizing these structures with other methods.

  1. Limitations on the use of the pulsed-wire field-measuring technique

    International Nuclear Information System (INIS)

    Warren, R.W.

    1987-09-01

    As wigglers become longer and the wavelength of the light they produce becomes shorter, the requirements for magnetic field uniformity and precision of wiggler construction become more severe. Techniques used to measure magnetic fields and to estimate the performance of wigglers are now being pushed to their limits in precision and are generally awkward and time consuming in practice. A new field-error measurement technique has been developed that has the usual advantages of a null technique, demonstrates high sensitivity to field errors, and is rapid and simple to employ. With this technique, it appears practical to use computer control to both measure and correct field errors. In a particularly attractive application, these measuring and correcting steps could be carried out on a daily basis for an operational wiggler, which is mounted under vacuum in its optical cavity. In this way, changes in the fields caused by aging or by thermal or radiation-induced deterioration effects could be rapidly identified and corrections could be instituted without significant interruption to normal operations. The principles and limitations of ths technique will be described and examples given of various implementations that have been examined experimentally. 10 refs., 2 figs., 2 tabs

  2. Biomechanical comparison of pin and tension-band wire fixation with a prototype locking plate fixation in a transverse canine patellar fracture model.

    Science.gov (United States)

    Gibert, Sophie; Kowaleski, Michael P; Matthys, Romano; Nützi, Reto; Serck, Boris; Boudrieau, Randy J

    2016-01-01

    To compare a locking plate (LP) with pin and tension-band wire (pin/TBW) for fixation of mid-patellar transverse fractures. Cadaveric canine stifle joints from 10 adult mixed breed dogs (23-36 kg) were used. Mid-patellar transverse osteotomies were randomly stabilized (in pairs) with either pin/TBW or a prototype LP. Cyclic loads (1 Hz, 500 cycles) at 100% body weight (90°-135° stifle joint extension), were applied. Survival or failure of constructs was defined as <2 mm fracture gap distraction at 500 cycles, or ≥2 mm fracture gap distraction at the number of cycles sustained, respectively. Number of cycles at failure and distraction gap were compared with a paired Student's t-test, and a survival analysis performed with a Mantel-Cox test. All constructs that survived cyclic testing were tested in single cycle load to failure (1.0 mm/sec; 110° stifle joint extension); yield strength was compared with a Wilcoxon rank sum test. Significance was set at p <0.05. All 10/10 LP and three out of 10 pin/TBW fixations survived cyclic testing. Survival analysis, number of cycles at failure, and distraction gap all were significantly different between the two groups (p = 0.0011, p = 0.0013, and p <0.0001, respectively). Construct yield strength was not significantly different (p = 0.1273). The failure mode with pin/TBW was consistently similar to failures observed clinically. The LP demonstrated consistent, reliable and stable fixation.

  3. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  4. Basic Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; And Others

    This module is the first in a series of three wiring publications; it serves as the foundation for students enrolled in a wiring program. It is a prerequisite to either "Residential Wiring" or "Commercial and Industrial Wiring." The module contains 16 instructional units that cover the following topics: occupational…

  5. Compact dual-band bandpass filter based on signal-interference techniques

    Science.gov (United States)

    Ma, Xingbing; Jiang, Ting

    2017-08-01

    To realize good isolation between two signal passbands, a dual-band bandpass filter (BPF) in this article was presented using signal-interference techniques, in which five open loop resonators are adopted. The proposed filter topology is made up of two signal transmission paths in parallel, under signal-interference principles, overlap section of two original passbands, decided respectively by two different transmission paths, is selectively removed from the combined passband, as a result, two aim passbands are realized. In addition, good isolation between two aim passbands is established due to two new transmission zeros, produced by adopted signal-interference techniques. At last, good agreement can be observed between simulation and measurement.

  6. Direct Repair of the Superior Band of Bigelow's Ligament After Hip Arthroplasty: a Surgical Technique.

    Science.gov (United States)

    Liu, Joseph; McLawhorn, Alexander S; Christ, Alexander B; Dzenis, Peteris; Healey, John H

    2016-07-01

    The posterolateral approach is one of the most common approaches used during hip arthroplasty. A posterior soft tissue repair is necessary to limit the risk of postoperative dislocation. For a trapezoidal capsulotomy, the proximal limb divides the superior band of the iliofemoral ligament (Bigelow's ligament). A transosseous repair frequently leaves a defect in this region, which may elevate the risk for dislocation. The purpose of this article is to describe a simple, rational technique for reinforcing the posterior capsular repair. A meticulous exposure of the hip capsule is performed during the posterolateral surgical approach. A trapezoidal capsulotomy is performed. After implantation of the arthroplasty implants, retractors are placed to expose the superior capsule. Prior to transosseous repair of the capsule and short external rotator tendons, the proximal limb of the capsulotomy is reapproximated anatomically and repaired with non-absorbable sutures. If anatomical repair is not possible, leg length and femoral offset should be reassessed carefully. The described modification may further minimize the risk of dislocation following hip arthroplasty, as the superior band of Bigelow's ligament is an additional checkrein to internal and external rotation. This repair provides a secondary intraoperative assessment of leg length and femoral offset to ensure proper biomechanical reconstruction of the hip joint. It is the authors' preferred technique of all hip hemiarthroplasties and total hip arthroplasties, whenever possible.

  7. Results of Patello-Tibial Cerclage Wire Technique for Comminuted Patella Fractures Treated with Partial Patellectomy

    Directory of Open Access Journals (Sweden)

    Ender Alagöz

    2014-12-01

    Full Text Available Aim: Partial patellectomy and patellotibial cerclage technique used in comminuted inferior pole patellar fractures were evaluated and the results were discussed. Methods: Thirteen patients who have undergone partial distal patellar excision were evaluated in the study. In all patients, the inferior pole of the patella was resected, patellar tendon was sutured to the proximal patellar fragment and patellotibial cerclage was performed. At the last visit, the patients were evaluated using measurement of the distance between the superior pole of the patella and the tibial tubercle, the Lysholm knee scoring scale, knee range of motion and thigh circumference measurement. Results: The mean flexion value was 131.10 (±4.6 in normal knees and 117.20 (±8.0 in operated knees. The mean thigh diameter was 49.5 (±3.7 cm and 46.4 (±4.5 cm in normal knees and in operated knees, respectively. The mean Lysholm knee score in the patient group was 84.3 (±17.1 points. The mean distance between the superior pole of the patella and the tibial tubercle was 10.6 (±1.0 cm in normal knees and 10.1 (±1.2 cm in operated knees. The exstensor mechanism was intact in all patients and no revision surgery was performed. Conclusion: Patellotibial cerclage technique performed after partial patellectomy permits early motion and protects patients from harmful effects of immobilization; and good functional results are obtained if patients start early knee motion.

  8. Cable pin system versus K-wire tension band fixation for patella fractures in Chinese Han population: A meta-analysis.

    Science.gov (United States)

    Zha, Kun; Liu, Guo-Hui; Yang, Shu-Hua; Zhou, Wu; Liu, Yi; Wu, Qi-Peng

    2017-10-01

    This meta-analysis compared the therapeutic effect of cable pin system (CPS) with K-wire tension band (KTB) in the treatment of patella fractures among Chinese Han population. The databases of PubMed, Cochrane library, China National Knowledge Infrastructure (CNKI), Chinese WanFang and Chinese VIP were searched for studies on CPS versus KTB in the treatment of patella fractures among Chinese Han population. Literatures were screened according to the inclusion and exclusion criteria. The quality of the studies was assessed, and meta-analysis was performed using the Cochrane Collaboration's REVMAN 5.3 software. A total of 932 patients from 15 studies were included in this meta-analysis (426 fractures treated with CPS and 506 fractures treated with KTB). There were significant differences in duration of hospital stay [mean difference (MD)=-1.07; 95% confidence interval (CI):-1.71 to-0.43], fracture healing time (MD=-1.23; 95% CI:-1.68 to-0.77), flexion degree of knee joint at 6th month after operation (MD=14.82; 95% CI: 10.93 to 18.71), incidence of postoperative complication [risk ratio (RR)=0.16; 95% CI: 0.09 to 0.27] and excellent-good rate of Böstman score (RR=1.09; 95% CI: 1.03 to 1.16) between the CPS group and KTB group, while no significant difference was found in operative time between the two groups (MD=-4.52; 95% CI:-11.70 to 2.67). For the treatment of patella fractures among Chinese Han population, limited evidence suggests that the CPS is more suitable than the KTB when considering the hospital stay, fracture healing time, flexion degree of knee at 6th month after operation, incidence of postoperative complication and excellent-good rate of Böstman joint score. Due to the limitation of high quality evidence and sample size, more large-scale randomized controlled trials are needed to validate the findings in the future.

  9. Technology optimization techniques for multicomponent optical band-pass filter manufacturing

    Science.gov (United States)

    Baranov, Yuri P.; Gryaznov, Georgiy M.; Rodionov, Andrey Y.; Obrezkov, Andrey V.; Medvedev, Roman V.; Chivanov, Alexey N.

    2016-04-01

    Narrowband optical devices (like IR-sensing devices, celestial navigation systems, solar-blind UV-systems and many others) are one of the most fast-growing areas in optical manufacturing. However, signal strength in this type of applications is quite low and performance of devices depends on attenuation level of wavelengths out of operating range. Modern detectors (photodiodes, matrix detectors, photomultiplier tubes and others) usually do not have required selectivity or have higher sensitivity to background spectrum at worst. Manufacturing of a single component band-pass filter with high attenuation level of wavelength is resource-intensive task. Sometimes it's not possible to find solution for this problem using existing technologies. Different types of filters have technology variations of transmittance profile shape due to various production factors. At the same time there are multiple tasks with strict requirements for background spectrum attenuation in narrowband optical devices. For example, in solar-blind UV-system wavelengths above 290-300 nm must be attenuated by 180dB. In this paper techniques of multi-component optical band-pass filters assembly from multiple single elements with technology variations of transmittance profile shape for optimal signal-tonoise ratio (SNR) were proposed. Relationships between signal-to-noise ratio and different characteristics of transmittance profile shape were shown. Obtained practical results were in rather good agreement with our calculations.

  10. Medial malleolar fractures: a biomechanical study of fixation techniques.

    Science.gov (United States)

    Fowler, T Ty; Pugh, Kevin J; Litsky, Alan S; Taylor, Benjamin C; French, Bruce G

    2011-08-08

    Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO group recommends tension-band fixation of small avulsion type fractures of the medial malleolus that are unacceptable for screw fixation. A well-documented complication of this technique is prominent symptomatic implants and secondary surgery for implant removal. Replacing stainless steel 18-gauge wire with FiberWire suture could theoretically decrease symptomatic implants. Therefore, a second goal was to biomechanically compare these 2 tension-band constructs. Using a tibial Sawbones model, 2 bicortical screws were compared with 2 unicortical cancellous screws on a servohydraulic test frame in offset axial, transverse, and tension loading. Second, tension-band fixation using stainless steel wire was compared with FiberWire under tensile loads. Bicortical screw fixation was statistically the stiffest construct under tension loading conditions compared to unicortical screw fixation and tension-band techniques with FiberWire or stainless steel wire. In fact, unicortical screw fixation had only 10% of the stiffness as demonstrated in the bicortical technique. In a direct comparison, tension-band fixation using stainless steel wire was statistically stiffer than the FiberWire construct. Copyright 2011, SLACK Incorporated.

  11. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  12. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  13. A New Technique for Superselective Catheterization of Arteries: Preshaping of a Micro-Guide Wire into a Shepherd's Hook Form

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jee Hyun; Chung; Jin Wook; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2007-06-15

    We wanted to introduce a new technique for superselective catheterization of arteries with preshaping of a micro-guide wire into a shepherd's hook form, and this is useful for superselection of small arteries branching at an acute angle from a large parent artery for the treatment of tumors and hemorrhages. We developed a superselective catheterization technique by using preshaping of a micro-guide wire into a shepherd's hook form. We encountered six patients in our practice for whom we failed to catheterize the small tumor-feeding arteries that branched at an acute angle from wide parent arteries during chemoembolization of hepatocellular carcinoma; the parent arteries were the right inferior phrenic artery (n = 4) and the left gastric artery (n = 1) from the celiac axis with celiac stenosis due to compression by the median arcuate ligament and the proper hepatic artery from the gastroduodenal artery (n = 1) in a patient who had celiac axis occlusion with collateral circulation via the pancreaticoduodenal arcade from the superior mesenteric artery. In these consecutive six patients, we tested the usefulness of this new technique with employing preshaping of a micro-guide wire into a shepherd's hook form for superselective catheterization of targeted vessels. The target arteries were successfully catheterized and satisfactory transcatheter arterial chemoembolization was performed in all six patients. There were no significant complications such as arterial dissection. We developed a technique that is effective for superselection of vessels with preshaping of micro-guide wire into a shepherd's hook hook form, and we successfully applied it during chemoembolization of hepatocellular carcinoma. This technique can be useful for superselection of small arteries that branch from a large parent artery at acute angles for the treatment of tumors and hemorrhages.

  14. Repair of olecranon fractures using fiberWire without metallic implants: report of two cases

    Directory of Open Access Journals (Sweden)

    Okawa Atsushi

    2010-10-01

    Full Text Available Abstract Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided.

  15. Digital implementation of a laser frequency stabilisation technique in the telecommunications band

    Science.gov (United States)

    Jivan, Pritesh; van Brakel, Adriaan; Manuel, Rodolfo Martínez; Grobler, Michael

    2016-02-01

    Laser frequency stabilisation in the telecommunications band was realised using the Pound-Drever-Hall (PDH) error signal. The transmission spectrum of the Fabry-Perot cavity was used as opposed to the traditionally used reflected spectrum. A comparison was done using an analogue as well as a digitally implemented system. This study forms part of an initial step towards developing a portable optical time and frequency standard. The frequency discriminator used in the experimental setup was a fibre-based Fabry-Perot etalon. The phase sensitive system made use of the optical heterodyne technique to detect changes in the phase of the system. A lock-in amplifier was used to filter and mix the input signals to generate the error signal. This error signal may then be used to generate a control signal via a PID controller. An error signal was realised at a wavelength of 1556 nm which correlates to an optical frequency of 1.926 THz. An implementation of the analogue PDH technique yielded an error signal with a bandwidth of 6.134 GHz, while a digital implementation yielded a bandwidth of 5.774 GHz.

  16. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  17. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  19. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  20. Tunable Band Gap Energy of Mn-Doped ZnO Nanoparticles Using the Coprecipitation Technique

    Directory of Open Access Journals (Sweden)

    Tong Ling Tan

    2014-01-01

    Full Text Available A simple coprecipitation technique was introduced to form manganese (Mn doped on zinc oxide (ZnO nanoparticles effectively. Based on our morphological studies, it was revealed that mean particle size was increased while bigger agglomeration of nanoparticles could be observed as the amount of concentration of Mn was increased. Interestingly, it was found that the position of the absorption spectra was shifted towards the lower wavelength (UV region as correlated with the increasing of Mn dopants concentration into ZnO nanoparticles. This result inferred that optimum content of Mn doped into the ZnO nanoparticles was crucial in controlling the visible/UV-responsive of samples. In the present study, 3 mol% of Mn dopants into the ZnO nanoparticles exhibited the better UV as well as visible light-responsive as compared to the other samples. The main reason might be attributed to the modification of electronic structure of ZnO nanoparticles via lattice doping of Mn ions into the lattice, whereas excessive Mn dopants doped on ZnO nanoparticles caused the strong UV-responsive due to the more 3d orbitals in the valence band.

  1. Experimental investigation on 3D-SEM reconstructions of a wire gauge using stereo-pair technique

    DEFF Research Database (Denmark)

    Carli, Lorenzo; Genta, G.; Cantatore, Angela

    2011-01-01

    stage. A wire gauge with a 250 μm reference diameter was adopted as calibrated artefact to perform an uncertainty evaluation of the diameter estimate, in terms of input parameters required by commercial software performing stereophotogrammetry. Systematic exploration of sample space was performed...

  2. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  3. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  5. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  6. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  7. Endoscopic extraction of adjustable gastric bands after intragastric migration as a complication of bariatric surgery: technique and advice.

    Science.gov (United States)

    Collado-Pacheco, David; Rábago-Torre, Luis Ramon; Arias-Rivera, Maria; Ortega-Carbonel, Alejandro; Olivares-Valles, Ana; Alonso-Prada, Alicia; Vázquez-Echarri, Jaime; Herrera-Merino, Norberto

    2016-06-01

    Surgery has been the method most widely used to manage the extraction of gastric bands with inclusion as a late complication of bariatric surgery; however, surgical extraction entails morbidity and limits future surgical procedures. The development of endoscopic techniques has provided an important means of improving the treatment of this complication, enabling minimally invasive and safe procedures that have a high success rate. A retrospective analysis was conducted of patients who had laparoscopic gastric banding complicated by intragastric migration and were treated endoscopically. A technique already described for managing this complication was employed. An MTW Endoskopie Dormia basket for mechanical lithotripsy or a standard 0.0035-in guidewire was placed around the band, and an MTW Endoskopie emergency lithotripter was used to section it, after which the band was extracted with a standard polypectomy snare. Also analyzed were the initial symptoms of patients with this complication, the mean time from surgery to development of the event, the success rate of endoscopic treatment, and complications, Results: A total of 127 patients had undergone gastric banding surgery in our Bariatric Surgery Center; of these, 12 patients (9.4 %) developed a complication such as intragastric migration of the band. Weight gain and pain were the main symptoms in 11 patients (92 %), and the mean time to the development of symptoms was 51.3 months. A single endoscopic treatment was successful in 7 of 9 patients (78 %). Only 1 complication, involving ventilation during anesthesia, occurred; no other adverse events were recorded. The endoscopic extraction of bands with inclusion is feasible and can be performed easily and successfully. The procedure is available in all hospitals and has a low incidence of related complications, so that unnecessary surgical procedures can be avoided.

  8. Percutaneous cerclage wiring and minimally invasive plate osteosynthesis (MIPO): a percutaneous reduction technique in the treatment of Vancouver type B1 periprosthetic femoral shaft fractures.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Phornphutkul, C; Bunmaprasert, T; Sananpanich, K; Fernandez Dell'Oca, Alberto

    2012-06-01

    Periprosthetic femoral fractures (PPFs) associated at or near a well-fixed femoral prostheses (Vancouver type-B1) present a clinical challenge due to the quality of the bone stock and instability of the fracture. The purpose of this study was to present a novel reduction technique and analyze clinical and radiographic outcome in patients with Vancouver type-B1 fractures treated with percutaneous cerclage wiring for fracture reduction and maintenance of reduction with minimally invasive plate osteosynthesis (MIPO) utilizing a locking compression plate (LCP). Between March 2007 and December 2008, ten consecutive patients with spiral, oblique or wedge Vancouver type-B1 were treated with closed percutaneous cerclage wiring using a new cerclage passer instrument (Synthes) through small 2-3 cm incisions for reduction and maintenance of reduction. Internal fixation with MIPO was obtained utilizing a long LCP Synthes bridging the fracture. The reduction time, fixation time and operative time were recorded. The rehabilitation protocol consisted of partial weight bearing as tolerated. Clinical and radiographic outcomes included evidence of union, return to pre-injury mobility, and surgical complications were recorded. There were three men and seven women with an average age of 74 years (range 47-84 years) at the time the fracture occured. The average follow-up was 13.2 months. One patient died 2 months after surgery due to cardiovascular problems and was excluded. The average reduction time with percutaneous cerclage wiring was 24.4 min (range 7-45 min). The average fixation time was 79 min (range 53-100 min). The average operative time was 103 min (range 75-140 min). Blood loss was minimal and only two patients needed a blood transfusion. All fractures healed with a mean time to union of 18 weeks (range 16-20 weeks). There was one implant which bent 10° in the post-operative period but went on to heal uneventfully within 16 weeks. There was no evidence of loosening of any

  9. Four-corner fusion: comparison of patient satisfaction and functional outcome of conventional K-wire technique vs. a new locking plate.

    Science.gov (United States)

    Hernekamp, J F; Reinecke, A; Neubrech, F; Bickert, B; Kneser, U; Kremer, T

    2016-04-01

    Four-corner fusion is a standard procedure for advanced carpal collapse. Several operative techniques and numerous implants for osseous fixation have been described. Recently, a specially designed locking plate (Aptus©, Medartis, Basel, Switzerland) was introduced. The purpose of this study was to compare functional results after osseous fixation using K-wires (standard of care, SOC) with four-corner fusion and locking plate fixation. 21 patients who underwent four-corner fusion in our institution between 2008 and 2013 were included in a retrospective analysis. In 11 patients, osseous fixation was performed using locking plates whereas ten patients underwent bone fixation with conventional K-wires. Outcome parameters were functional outcome, osseous consolidation, patient satisfaction (DASH- and Krimmer Score), pain and perioperative morbidity and the time until patients returned to daily work. Patients were divided in two groups and paired t-tests were performed for statistical analysis. No implant related complications were observed. Osseous consolidation was achieved in all cases. Differences between groups were not significant regarding active range of motion (AROM), pain and function. Overall patient satisfaction was acceptable in all cases; differences in the DASH questionnaire and the Krimmer questionnaire were not significant. One patient of the plate group required conversion to total wrist arthrodesis without implant-related complications. Both techniques for four-corner fusion have similar healing rates. Using the more expensive locking implant avoids a second operation for K-wire removal, but no statistical differences were detected in functional outcome as well as in patient satisfaction when compared to SOC.

  10. Reduction of the In-Band RCS of Microstrip Patch Antenna by Using Offset Feeding Technique

    Directory of Open Access Journals (Sweden)

    Weiwei Xu

    2014-01-01

    Full Text Available This paper presents a method for implementing a low in-band scattering design for microstrip patch antennas based on the analysis of structural mode scattering and radiation characteristics. The antenna structure is first designed to have the lowest structural mode scattering in a desired frequency band. The operating frequency band of the antenna is then changed to coincide with that of the lowest structural mode scattering by adjusting the feed position on the antenna (offset feeding to achieve an antenna with low in-band radar cross section (RCS. In order to reduce the level of cross polarization of the antenna caused by offset feeding, symmetry feeding structures for both single patch antennas and two-patch arrays are proposed. Examples that show the efficiency of the method are given, and the results illustrate that the in-band RCS of the proposed antennas can be reduced by as much as 17 dBsm for plane waves impinging from the normal direction compared to patch antennas fed by conventional methods.

  11. Wire Rupture Optimization in Wire Electrical Discharge Machining using Taguchi Approach

    Directory of Open Access Journals (Sweden)

    Maher Ibrahem

    2017-01-01

    Full Text Available Wire electrical discharge machining (WEDM is one of the most important nontraditional machining process that is well-known for cutting difficult to machine materials. The wire electrode along with machining parameters control the WEDM process. This research work focuses on optimizing WEDM parameters using Taguchi technique to minimize wire rupture. Experiments have been done using the L18 orthogonal array. Each experiment is repeated three times to ensure accurate readings of the wire rupture. The statistical methods of signal to noise ratio (S/N ratio is applied to study effects of peak current, pulse width, charging time, wire speed, and wire tension on wire rupture. As a results, the peak current, pulse width, and wire tension have the most significant effect on wire rupture followed by charging time and wire speed. The developed analysis can be used in the metal cutting field to identify the optimum machining parameters for less wire rupture.

  12. Endoscopic extraction of adjustable gastric bands after intragastric migration as a complication of bariatric surgery: technique and advice

    OpenAIRE

    Collado-Pacheco, David; R?bago-Torre, Luis Ramon; Arias-Rivera, Maria; Ortega-Carbonel, Alejandro; Olivares-Valles, Ana; Alonso-Prada, Alicia; V?zquez-Echarri, Jaime; Herrera-Merino, Norberto

    2016-01-01

    Background: Surgery has been the method most widely used to manage the extraction of gastric bands with inclusion as a late complication of bariatric surgery; however, surgical extraction entails morbidity and limits future surgical procedures. The development of endoscopic techniques has provided an important means of improving the treatment of this complication, enabling minimally invasive and safe procedures that have a high success rate. Methods: A retrospective analysis was conducted of ...

  13. Multi-band effective mass approximations advanced mathematical models and numerical techniques

    CERN Document Server

    Koprucki, Thomas

    2014-01-01

    This book addresses several mathematical models from the most relevant class of kp-Schrödinger systems. Both mathematical models and state-of-the-art numerical methods for adequately solving the arising systems of differential equations are presented. The operational principle of modern semiconductor nano structures, such as quantum wells, quantum wires or quantum dots, relies on quantum mechanical effects. The goal of numerical simulations using quantum mechanical models in the development of semiconductor nano structures is threefold: First they are needed for a deeper understanding of experimental data and of the operational principle. Secondly, they allow us to predict and optimize in advance the qualitative and quantitative properties of new devices in order to minimize the number of prototypes needed. Semiconductor nano structures are embedded as an active region in semiconductor devices. Thirdly and finally, the results of quantum mechanical simulations of semiconductor nano structures can be used wit...

  14. CMOS front-end techniques for in-band full-duplex radio

    NARCIS (Netherlands)

    van den Broek, Dirk-Jan

    2017-01-01

    In-band full-duplex wireless communication (FD), i.e. transmission and reception at the same time at the same frequency, is an emerging research topic, driven by the increasing demand for mobile data traffic in the crowded radio spectrum. Besides promising up to twice the spectral efficiency,

  15. The biomechanical evaluation of polyester as a tension band for the internal fixation of patellar fractures.

    LENUS (Irish Health Repository)

    McGreal, G

    2012-02-03

    We use a braided polyester suture in place of cerclage wire in tension band fixations. The objective of this study was to test the biomechanical properties of this technique. Sixteen cadaveric patellae were fractured and repaired by modified tension band fixation. Eight were fixed using eighteen gauge stainless steel wire as a tension band and eight using braided polyester. All specimens were subjected to tensile testing. Polyester was 75.0% as strong as wire. For dynamic testing, the patellae of seven cadaveric knees were fractured and then fixed with polyester tension bands. These were mounted in a device capable of extending the knees from 90 degrees to neutral against an applied force. None of the fixations failed. Three of the specimens fixed using 18 gauge stainless steel wire were compared with three fixed using polyester over 2000 cycles of knee flexion and extension. Polyester performed as well as wire. We conclude that polyester is an acceptable alternative to wire in tension band fixation.

  16. Wavelength influence in sub-pixel temperature retrieval using the dual-band technique

    OpenAIRE

    Lombardo, V.; Merucci, L.; Buongiorno, M. F.

    2006-01-01

    The thermal model proposed by Crisp and Baloga (1990) for active lava flows considers thermal flux as a function of the fractional area of two thermally distinct radiant surfaces. In this model, the larger surface area corresponds to the cooler crust of the flow and the other, much smaller to fractures in the crust. These cracks temperature is much higher than the crust one and approaches the temperature of the molten or plastic interior flow. The dual-band method needs two distinct SWIR (sho...

  17. Evaluation and Performance Analysis of 3D Printing Technique for Ka-Band Antenna Production

    DEFF Research Database (Denmark)

    Armendariz, Unai; Rommel, Simon; Rodríguez Páez, Juan Sebastián

    2016-01-01

    This paper presents the design and fabrication of 3D printed WR-28 waveguide horn antennas operating in the Ka-band frequency range between 26.5GHz and 40GHz. Three antennas are fabricated from polylactide acid filaments in conductive and non-conductive variants; the latter is covered...... with conductive paint. The gain and voltage standing wave ratio performance of the fabricated horn antennas is measured, showing promising performance. Antenna gain values between 5dBi and 14 dBi are found, comparable to the performance of metal milled horn antennas....

  18. A Broadband Microwave Radiometer Technique at X-band for Rain and Drop Size Distribution Estimation

    Science.gov (United States)

    Meneghini, R.

    2005-01-01

    Radiometric brightess temperatures below about 12 GHz provide accurate estimates of path attenuation through precipitation and cloud water. Multiple brightness temperature measurements at X-band frequencies can be used to estimate rainfall rate and parameters of the drop size distribution once correction for cloud water attenuation is made. Employing a stratiform storm model, calculations of the brightness temperatures at 9.5, 10 and 12 GHz are used to simulate estimates of path-averaged median mass diameter, number concentration and rainfall rate. The results indicate that reasonably accurate estimates of rainfall rate and information on the drop size distribution can be derived over ocean under low to moderate wind speed conditions.

  19. On the preparation of superconducting wires

    International Nuclear Information System (INIS)

    Topare, R.J.; Chinchure, A.D.; Shah, S.S.; Hadole, G.B.

    1993-01-01

    The different methods of preparation of superconducting wires have been discussed. The powder-in-tube technique is followed for the preparation of YBCO and BISCCO superconducting wires. The results are discussed. The present status of the industries in preparing the superconducting wires having the maximum J c values is discussed. (author). 30 refs., 6 figs., 2 tabs

  20. High Resolution Radar Imaging using Coherent MultiBand Processing Techniques

    NARCIS (Netherlands)

    Dorp, Ph. van; Ebeling, R.P.; Huizing, A.G.

    2010-01-01

    High resolution radar imaging techniques can be used in ballistic missile defence systems to determine the type of ballistic missile during the boost phase (threat typing) and to discriminate different parts of a ballistic missile after the boost phase. The applied radar imaging technique is 2D

  1. The Rubber Stopper: A Simple and Inexpensive Technique to Prevent Pin Tract Infection following Kirschner Wiring of Supracondylar Fractures of Humerus in Children.

    Science.gov (United States)

    Santy, J E; Kamal, J; Abdul-Rashid, A H; Ibrahim, S

    2015-07-01

    Percutaneous pinning after closed reduction is commonly used to treat supracondylar fractures of the humerus in children. Minor pin tract infections frequently occur. The aim of this study was to prevent pin tract infections using a rubber stopper to reduce irritation of the skin against the Kirschner (K) wire following percutaneous pinning. Between July 2011 and June 2012, seventeen children with closed supracondylar fracture of the humerus of Gartland types 2 and 3 were treated with this technique. All patients were treated with closed reduction and percutaneous pinning and followed up prospectively. Only one patient, who was a hyperactive child, developed pin tract infection due to softening of the plaster slab. We found using the rubber stopper to be a simple and inexpensive method to reduce pin tract infections following percutaneous pinning.

  2. The Development of Layered Photonic Band Gap Structures Using a Micro-Transfer Molding Technique

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, Kevin Jerome [Iowa State Univ., Ames, IA (United States)

    2001-06-27

    Over the last ten years, photonic band gap (PBG) theory and technology have become an important area of research because of the numerous possible applications ranging from high-efficiency laser diodes to optical circuitry. This research concentrates on reducing the length scale in the fabrication of layered photonic band gap structures and developing procedures to improve processing consistency. Various procedures and materials have been used in the fabrication of layered PBG structures. This research focused on an economical micro transfer molding approach to create the final PBG structure. A poly dimethylsiloxane (PDMS) rubber mold was created from a silicon substrate. It was filled with epoxy and built layer-by-layer to create a 3-D epoxy structure. This structure was infiltrated with nanoparticle titania or a titania sol-gel, then fired to remove the polymer mold, leaving a monolithic ceramic inverse of the epoxy structure. The final result was a lattice of titania rolds that resembles a face-centered tetragonal structure. The original intent of this research was to miniaturize this process to a bar size small enough to create a photonic band gap for wavelengths of visible electro-magnetic radiation. The factor limiting progress was the absence of a silicon master mold of small enough dimensions. The Iowa State Microelectronics Research Center fabricated samples with periodicities of 2.5 and 1.0 microns with the existing technology, but a sample was needed on the order of 0.3 microns or less. A 0.4 micron sample was received from Sandia National Laboratory, which was made through an electron beam lithography process, but it contained several defects. The results of the work are primarily from the 2.5 and 1.0 micron samples. Most of the work focused on changing processing variables in order to optimize the infiltration procedure for the best results. Several critical parameters were identified, ranging from the ambient conditions to the specifics of the

  3. Ultra Wide X-Band Microwave Imaging of Concealed Weapons and Explosives Using 3D-SAR Technique

    Directory of Open Access Journals (Sweden)

    P. Millot

    2015-01-01

    Full Text Available In order to detect and image concealed weapons and explosives, an electromagnetic imaging tool with its related signal processing is presented. The aim is to penetrate clothes and to find personal-born weapons and explosives under clothes. The chosen UWB frequency range covers the whole X-band. The frequency range is justified after transmission measurements of numerous clothes that are dry or slightly wet. The apparatus and the 3D near-field SAR processor are described. A strategy for contour identification is presented with results of some simulants of weapon and explosive. A conclusion is drawn on the possible future of this technique.

  4. Comparison of neurophysiological and MRI findings of patients with multiple sclerosis using oligoclonal band technique.

    Science.gov (United States)

    Ellidag, Hamit Y; Eren, Esin; Erdogan, Nezahat; Ture, Sabiha; Yilmaz, Necat

    2013-10-01

    The correlation of oligoclonal bands (OCBs) and intrathecal IgG synthesis are not yet clear in multiple sclerosis (MS). In this study, we investigated the OCB situation and IgG index, cranial and cervical magnetic resonance imaging (MRI) findings and also compared visual evoked potentials (VEP) and somatosensorial evoked potentials (SEP) in order to better understand the OCB pattern and pathogenesis. Retrospective study included 40 patients (19 male, 21 female, mean age 29 ± 4,24) with precise MS diagnosis according to McDonald criteria. Sixteen of the patients were OCB negative, and 24 patients were positive. The different between the OCB situation and number of plaques in cranial and cervical MRI, atrophy, oedema and contrast material retention were insignificant. The different between the OCB situation and VEP and SEP were insignificant. These laboratory findings are all specific, all developing via independent mechanisms and are not related to each other during the silence periods of patients.

  5. Semi-Empirical Validation of the Cross-Band Relative Absorption Technique for the Measurement of Molecular Mixing Ratios

    Science.gov (United States)

    Pliutau, Denis; Prasad, Narasimha S

    2013-01-01

    Studies were performed to carry out semi-empirical validation of a new measurement approach we propose for molecular mixing ratios determination. The approach is based on relative measurements in bands of O2 and other molecules and as such may be best described as cross band relative absorption (CoBRA). . The current validation studies rely upon well verified and established theoretical and experimental databases, satellite data assimilations and modeling codes such as HITRAN, line-by-line radiative transfer model (LBLRTM), and the modern-era retrospective analysis for research and applications (MERRA). The approach holds promise for atmospheric mixing ratio measurements of CO2 and a variety of other molecules currently under investigation for several future satellite lidar missions. One of the advantages of the method is a significant reduction of the temperature sensitivity uncertainties which is illustrated with application to the ASCENDS mission for the measurement of CO2 mixing ratios (XCO2). Additional advantages of the method include the possibility to closely match cross-band weighting function combinations which is harder to achieve using conventional differential absorption techniques and the potential for additional corrections for water vapor and other interferences without using the data from numerical weather prediction (NWP) models.

  6. LAND SUBSIDENCE MONITORING USING PS-InSAR TECHNIQUE FOR L-BAND SAR DATA

    Directory of Open Access Journals (Sweden)

    S. Thapa

    2016-10-01

    Full Text Available Differential SAR-Interferometry (D-InSAR is one of the potential source to measure land surface motion induced due to underground coal mining. However, this technique has many limitation such as atmospheric in homogeneities, spatial de-correlation, and temporal decorrelation. Persistent Scatterer Interferometry synthetic aperture radar (PS-InSAR belongs to a family of time series InSAR technique, which utilizes the properties of some of the stable natural and anthropogenic targets which remain coherent over long time period. In this study PS-InSAR technique has been used to monitor land subsidence over selected location of Jharia Coal field which has been correlated with the ground levelling measurement. This time series deformation observed using PS InSAR helped us to understand the nature of the ground surface deformation due to underground mining activity.

  7. Asymmetric Dual-Band Tracking Technique for Optimal Joint Processing of BDS B1I and B1C Signals.

    Science.gov (United States)

    Wang, Chuhan; Cui, Xiaowei; Ma, Tianyi; Zhao, Sihao; Lu, Mingquan

    2017-10-16

    Along with the rapid development of the Global Navigation Satellite System (GNSS), satellite navigation signals have become more diversified, complex, and agile in adapting to increasing market demands. Various techniques have been developed for processing multiple navigation signals to achieve better performance in terms of accuracy, sensitivity, and robustness. This paper focuses on a technique for processing two signals with separate but adjacent center frequencies, such as B1I and B1C signals in the BeiDou global system. The two signals may differ in modulation scheme, power, and initial phase relation and can be processed independently by user receivers; however, the propagation delays of the two signals from a satellite are nearly identical as they are modulated on adjacent frequencies, share the same reference clock, and undergo nearly identical propagation paths to the receiver, resulting in strong coherence between the two signals. Joint processing of these signals can achieve optimal measurement performance due to the increased Gabor bandwidth and power. In this paper, we propose a universal scheme of asymmetric dual-band tracking (ASYM-DBT) to take advantage of the strong coherence, the increased Gabor bandwidth, and power of the two signals in achieving much-reduced thermal noise and more accurate ranging results when compared with the traditional single-band algorithm.

  8. Underlay Spectrum Sharing Techniques with In-Band Full-Duplex Systems using Improper Gaussian Signaling

    KAUST Repository

    Gaafar, Mohamed

    2016-10-26

    Sharing the spectrum with in-band full-duplex (FD) primary users (PUs) is a challenging and interesting problem in the underlay cognitive radio (CR) systems. The self-interference introduced at the primary network may dramatically impede the secondary user (SU) opportunity to access the spectrum. To tackle this problem, we use the so-called improper Gaussian signaling. Particularly, we assume the downlink transmission of a SU that uses improper Gaussian signaling while the FD PU pair implements the regular proper Gaussian signaling. First, we derive a closed form expression and an upper bound for the SU and PUs outage probabilities, respectively. Second, we optimize the SU signal parameters to minimize its outage probability while maintaining the required PUs quality-of-service based on the average channel state information (CSI). Moreover, we provide the conditions to reap merits from employing improper Gaussian signaling at the SU. Third, we design the SU signal parameters based on perfect knowledge of its direct link instantaneous CSI and investigate all benefits that can be achieved at both the SU and PUs. Finally, we provide some numerical results that demonstrate the advantages of using improper Gaussian signaling to access the spectrum of the FD PUs.

  9. Percutaneous balloon pulmonary valvuloplasty: A modified over-the-wire Inoue balloon technique for difficult right ventricular anatomy

    Directory of Open Access Journals (Sweden)

    Surender Deora

    2014-03-01

    Full Text Available Percutaneous balloon pulmonary valvuloplasty (BPV is the mainstay of treatment for significant pulmonary stenosis with doming leaflets. Various techniques have been described in the literature including the use of Inoue Percutaneous Transseptal Mitral Commissurotomy (PTMC catheter with standard 0.025″ guidewire. But if right ventricular anatomy is not suitable, 0.025″ guidewire doesn't provide enough support to track the Inoue PTMC catheter. Here, we report a case of successful BPV using a novel technique of slenderizing the Inoue Percutaneous Transseptal Mitral Commissurotomy (PTMC catheter over an Amplatz superstiff 0.035″ guidewire. This technique may be useful during BPV in difficult right ventricular inflow and outflow tract anatomy in patients with congenital pulmonary valve stenosis.

  10. Successful Percutaneous Retrieval of a Guiding Catheter Tip that Had Unexpectedly Become Detached Using a Two-Wire Technique.

    Science.gov (United States)

    Kume, Kiyoshi; Yasuoka, Yoshinori; Sasaki, Tatsuya

    2016-12-01

    Device dislodgement during percutaneous coronary intervention (PCI) is a rare but potentially life-threatening complication. We herein report the successful retrieval of a guiding catheter tip that had unexpectedly become detached in the right coronary artery during PCI in a 68-year-old man. Interventional cardiologists must be familiar with a safer and more reliable retrieval technique.

  11. Spectroscopic properties of colloidal indium phosphide quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lin-Wang; Wang, Fudong; Yu, Heng; Li, Jingbo; Hang, Qingling; Zemlyanov, Dmitry; Gibbons, Patrick C.; Wang, Lin-Wang; Janes, David B.; Buhro, William E.

    2008-07-11

    Colloidal InP quantum wires are grown by the solution-liquid-solid (SLS) method, and passivated with the traditional quantum dots surfactants 1-hexadecylamine and tri-n-octylphosphine oxide. The size dependence of the band gaps in the wires are determined from the absorption spectra, and compared to other experimental results for InP quantum dots and wires, and to the predictions of theory. The photoluminescence behavior of the wires is also investigated. Efforts to enhance photoluminescence efficiencies through photochemical etching in the presence of HF result only in photochemical thinning or photo-oxidation, without a significant influence on quantum-wire photoluminescence. However, photo-oxidation produces residual dot and rod domains within the wires, which are luminescent. The results establish that the quantum-wire band gaps are weakly influenced by the nature of the surface passivation, and that colloidal quantum wires have intrinsically low photoluminescence efficiencies.

  12. Multi-Response Optimization and Regression Analysis of Process Parameters for Wire-EDMed HCHCr Steel Using Taguchi’s Technique

    Directory of Open Access Journals (Sweden)

    K. Srujay Varma

    2017-04-01

    Full Text Available In this study, effect of machining process parameters viz. pulse-on time, pulse-off time, current and servo-voltage for machining High Carbon High Chromium Steel (HCHCr using copper electrode in wire EDM was investigated. High Carbon High Chromium Steel is a difficult to machine alloy, which has many applications in low temperature manufacturing, and copper is chosen as electrode as it has good electrical conductivity and most frequently used electrode all over the world. Tool making culture of copper has made many shops in Europe and Japan to used copper electrode. Experiments were conducted according to Taguchi’s technique by varying the machining process parameters at three levels. Taguchi’s method based on L9 orthogonal array was followed and number of experiments was limited to 9. Experimental cost and time consumption was reduced by following this statistical technique. Targeted output parameters are Material Removal Rate (MRR, Vickers Hardness (HV and Surface Roughness (SR. Analysis of Variance (ANOVA and Regression Analysis was performed using Minitab 17 software to optimize the parameters and draw relationship between input and output process parameters. Regression models were developed relating input and output parameters. It was observed that most influential factor for MRR, Hardness and SR are Ton, Toff and SV.

  13. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  14. From analog timers to the era of machine learning: The case of the transient hot-wire technique

    Science.gov (United States)

    Assael, Yannis M.; Antoniadis, Konstantinos D.; Assael, Marc J.

    2017-07-01

    In this work, we demonstrate how interdisciplinary knowledge can provide solutions to elusive challenges and advance science. As an example, we used the application of the THW in the measurement of the thermal conductivity of solids. To obtain a solution of the equations by FEM, about 10 h were required. By employing tools from the field of machine learning and computer science like a) automating the manual pipeline using a custom framework, b) using efficiently, Bayesian Optimisation to estimate the optimal thermal properties value, and c) applying further task specific optimisations, this time was reduced to 3 min, which is acceptable, and thus the technique can be easier used.

  15. Measurement of the Dielectric Constant of Seawater at L-Band: Techniques and Measurements

    Science.gov (United States)

    Lang, R.; Utku, C.; Tarkocin, Y.; LeVine, D.

    2009-01-01

    Satellite instruments, that will monitor salinity from space in the near future, require an accurate relationship between salinity/temperature and seawater dielectric constant. This paper will review measurements that were made of the dielectric constant of seawater during the past several years. The objective of the measurements is to determine the dependence of the dielectric constant of seawater on salinity and on temperature, more accurately than in the past. by taking advantage of modem instrumentation. The measurements of seawater permittivity have been performed as a function of salinity and temperature using a transmission resonant cavity technique. The measurements have been made in the salinity range of 10 to 38 psu and in the temperature range of IOU C to 35 C. These results will be useful in algorithm development for sensor systems such as SMOS and Aquarius. The measurement system consists of a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The diameter of the tube has been made very small so that the amount of seawater introduced in the cavity is small - thus maintaining the sensitivity of the measurements and allowing the use of perturbation theory predicting the seawater permittivity. The change in resonant frequency and the change in cavity Q can be used to determine the real and imaginary pare of the dielectric constant of seawater introduced into the slender tube. The microwave measurements are made by an HPS722D network analyzer. The cavity has been immersed in a uateriethylene-glycol bath which is connected to a Lauda circulator. The circulator keeps the brass cavity at a temperature constant to within 0.01 degrees. The system is automated using a Visual Basic program to control the analyzer and to collect the data. The results of the dielectric constant measurements of seawater will be presented. The measurement results will be

  16. Repair of Unstable Posterior Sternoclavicular Dislocation Using Nonabsorbable Tape Suture and Tension Band Technique: A Case Report with Good Results

    Directory of Open Access Journals (Sweden)

    Ekrem Aydın

    2015-01-01

    Full Text Available Posterior sternoclavicular joint dislocation (PSCJD is quite a rare condition. Nearly half of the closed reduction attempts fail due to various reasons. In this paper, we present a 25-year-old male patient who was admitted to the emergency department in our hospital after having a motor-vehicle accident. It was decided to do PSCJD after physical and imaging studies. Following necessary preparations, closed reduction was attempted with abduction-traction maneuver under general anesthesia; however, adequate stabilization could not be achieved and redislocation was detected during control. Therefore, joint was stabilized with tension band technique using 6 mm polyamide nonabsorbable type suture during open reduction. Painless and complete range of motion in shoulder was achieved at the postoperative 10th week.

  17. A very wide band telescope for Planck using optical and radio frequency techniques

    Science.gov (United States)

    Fargant, Guy; Dubruel, Denis; Cornut, Myriam; Riti, Jean-Bernard; Passvogel, Thomas; de Maagt, Peter; Anderegg, Michel; Tauber, Jan

    2017-11-01

    Planck associated to FIRST is one of the ESA scientific missions belonging to the Horizon 2000 programme. It will be launched by an Ariane 5 in 2007. Planck aims at obtaining very accurate images of the Cosmic Microwave Background fluctuations, thanks to a spaceborne telescope featuring a wide wavelength range and an excellent control of straylight and thermal variations. The telescope is based on an off-axis gregorian design consisting of two concave ellipsoidal mirrors with a 1.5-meter pupil, derived from radio frequency antenna, but with a very wide spectral domain which ranges from far infrared (350 μm) up to millimetric wavelengths (10 mm). Its field of view is large (10 degrees) owing to a high number of detectors in the focal plane. The short wavelength detectors (bolometers operating at 0.1 K) are located at the centre of the focal plane unit while the long wavelength ones (based on HEMT amplifier technology operating at 20 K) are located at the periphery. The Planck telescope operates at a temperature below 60 K. This level is achieved in a passive way, i.e. using a cryogenic radiator. Furthermore, this radiator must accommodate a set of coolers dedicated to the focal plane unit, cooling one of the experiments down to 0.1 K. The Planck mission leads to very stringent requirements (straylight, thermal stability) that can only be achieved by designing the spacecraft at system level, combining optical, radio frequency and thermal techniques in order to achieve the required performance.

  18. Magnetic anisotropy and anisotropic ballistic conductance of thin magnetic wires

    International Nuclear Information System (INIS)

    Sabirianov, R.

    2006-01-01

    The magnetocrystalline anisotropy of thin magnetic wires of iron and cobalt is quite different from the bulk phases. The spin moment of monatomic Fe wire may be as high as 3.4 μ B , while the orbital moment as high as 0.5 μ B . The magnetocrystalline anisotropy energy (MAE) was calculated for wires up to 0.6 nm in diameter starting from monatomic wire and adding consecutive shells for thicker wires. I observe that Fe wires exhibit the change sign with the stress applied along the wire. It means that easy axis may change from the direction along the wire to perpendicular to the wire. We find that ballistic conductance of the wire depends on the direction of the applied magnetic field, i.e. shows anisotropic ballistic magnetoresistance. This effect occurs due to the symmetry dependence of the splitting of degenerate bands in the applied field which changes the number of bands crossing the Fermi level. We find that the ballistic conductance changes with applied stress. Even for thicker wires the ballistic conductance changes by factor 2 on moderate tensile stain in our 5x4 model wire. Thus, the ballistic conductance of magnetic wires changes in the applied field due to the magnetostriction. This effect can be observed as large anisotropic BMR in the experiment

  19. Atmospheric extinction coefficient retrieval and validation for the single-band Mie-scattering Scheimpflug lidar technique.

    Science.gov (United States)

    Mei, Liang; Guan, Peng; Yang, Yang; Kong, Zheng

    2017-08-07

    An 808 nm single-band Mie scattering Scheimpflug lidar system is developed in Dalian, Northern China, for real-time, large-area atmospheric aerosol/particle remote sensing. Atmospheric measurement has been performed in urban area during a typical haze weather condition, and time-range distribution of atmospheric backscattering signal is recorded from March 18th to 22nd, 2017, by employing the Scheimpflug lidar system. Atmospheric extinction coefficient is then retrieved according to the Klett-inversion algorithm, while the boundary value is obtained by the slope-method in the far end where the atmosphere is homogeneous in a subinterval region. The correlation between the extinction coefficients retrieved from the Scheimpflug lidar technique and the PM10/PM2.5 concentrations measured by a conventional air pollution monitoring station is also studied. The good agreement between the measurement results, i.e., a correlation coefficient of 0.85, successfully demonstrates the feasibility and great potential of the Scheimpflug lidar technique for atmospheric studies and applications.

  20. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  1. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  2. A Vibrating Wire System For Quadrupole Fiducialization

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization step of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method

  3. Low-elevation tracking technique for X-band unmanned aerial vehicle automatic take-off and landing system

    Science.gov (United States)

    Lin, S.-Y.; Cho, M.-H.; Lin, M.-Y.; Hu, W.-Y.; Sun, J.-S.

    2017-05-01

    In this study, an automatic take-off and landing system (ATOLS) based on radar guidance was developed to provide day/night, all weather, automatic takeoff and landing for unmanned aerial vehicles (UAVs). The ATOLS contains a ground-based tracking radar subsystem and an airborne transponder subsystem. This X-band tracking radar can provide precise position information for UAV-control operations (transponder mode) and fire-control systems (skin mode). It provides 360 degrees of azimuth coverage and therefore can be employed for navigation applications. Its maximum tracking range is about 17 km and accuracy of altitude measurement is about 1 ft with a 50-ft decision height above ground level. To substantiate the proposed ATOLS system, a differential global positioning system (DGPS) was also developed. When a UAV at a low-elevation angle is detected and tracked by a tracking radar, multipath propagation often leads to the degradation of tracking accuracy or even cause the radar to break track. As a result, it becomes a potential risk to flight safety of the ATOLS guidance and control of UAVs. To overcome this technical difficulty, this paper proposes a solution based on optimization of radar parameters to mitigate the interference from multipath signals. The feasibility of proposed method has been experimentally proven through the flight trials of UAVs. Compared to the conventional low-elevation tracking techniques, the proposed one employs the radar signal processing, and does not consume additional hardware and resources.

  4. Compact Liquid Crystal Based Tunable Band-Stop Filter with an Ultra-Wide Stopband by Using Wave Interference Technique

    Directory of Open Access Journals (Sweden)

    Longzhu Cai

    2017-01-01

    Full Text Available A wave interference filtering section that consists of three stubs of different lengths, each with an individual stopband of its own central frequency, is reported here for the design of band-stop filters (BSFs with ultra-wide and sharp stopbands as well as large attenuation characteristics. The superposition of the individual stopbands provides the coverage over an ultra-wide frequency range. Equations and guidelines are presented for the application of a new wave interference technique to adjust the rejection level and width of its stopband. Based on that, an electrically tunable ultra-wide stopband BSF using a liquid crystal (LC material for ultra-wideband (UWB applications is designed. Careful treatment of the bent stubs, including impedance matching of the main microstrip line and bent stubs together with that of the SMA connectors and impedance adaptors, was carried out for the compactness and minimum insertion and reflection losses. The experimental results of the fabricated device agree very well with that of the simulation. The centre rejection frequency as measured can be tuned between 4.434 and 4.814 GHz when a biased voltage of 0–20 Vrms is used. The 3 dB and 25 dB stopband bandwidths were 4.86 GHz and 2.51 GHz, respectively, which are larger than that of other recently reported LC based tunable BSFs.

  5. OFDM techniques for narrow-band power line communications; OFDM-Verfahren fuer die schmalbandige Datenuebertragung im elektrischen Energieversorgungsnetz

    Energy Technology Data Exchange (ETDEWEB)

    Hoch, Martin

    2012-07-01

    In Power Line Communications (PLC) the power distribution grid is modelled by a frequency-selective time-variant channel. Therefore, OFDM techniques are suited very well for this application since they equalize the frequency-selective behaviour in a simple fashion. For narrow-band PLC, where only little amounts of data are to be transmitted, it is advantageous to employ a non-coherent system that does not need a training sequence for channel estimation. Such type of system can be brought up with CyclicPrefix OFDM in combination with Differential Phase-Shift Keying (DPSK). In an alternative, Unique-Word OFDM, the guard interval is not filled by a cyclic prefix, but a ''unique word'', which can be deployed for channel estimation. However, there is a loss in signal-to-noise power ratio due to the special type of signal generation. This loss can be more than regained in principle, but only by applying expensive detection. Another interesting technique is Wavelet-OFDM as its transmit spectrum can be formed outstandingly because of extended transmit pulses. This implies a large overhead when short packets of data are transmitted - additionally to a training sequence, for non-coherent detection is not possible. Cyclic-Prefix OFDM and DPSK are the basis of the Physical Layers of the PLC systems ''PLC G3'' and ''PRIME''. Comparing their specifications and analyzing simulation results ''PLC G3'' turns out to be the more reliable system. In order to equalize the time-variant behaviour of the power line channel, linear equalization and Multiple Symbol Differential Detection is studied as well as algorithms to estimate the time-variant envelope. (orig.)

  6. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  7. Raman spectroscopy of WO3 nano-wires and thermo-chromism study of VO2 belts produced by ultrasonic spray and laser pyrolysis techniques

    CSIR Research Space (South Africa)

    Mwakikunga, BW

    2008-01-01

    Full Text Available Novel optical and electrical properties of newly synthesized nano-wires of monoclinic WO3 and nano-belts of rutile VO2 have been investigated by Raman spectroscopy and thermochromism studies respectively. Phonon confinement is observed in the WO3...

  8. Magnetic wires in MEMS and bio-medical applications

    International Nuclear Information System (INIS)

    Barbic, Mladen

    2002-01-01

    Magnetic wires of appropriate design have special features making them useful to micro-electromechanical systems and bio-medical applications. Several applications that exploit the properties of magnetic wires are reviewed including: (a) a magnetic micro-manipulation technique that utilizes integrated micro-coils and magnetic micro-wires for localized positioning of micron-sized magnetic objects, (b) integrated micro-coil/micro-wire system operating as a micro-fluidic micro-motor, (c) mechanical tweezers using magneto-static interaction between two magnetic micro-wires, and (d) ultra-high gradient magnetic separation system based on porous membranes partially filled with magnetic wires

  9. Strength of stainless steel surgical wire in various fixation modes.

    Science.gov (United States)

    Schultz, R S; Boger, J W; Dunn, H K

    1985-09-01

    Although wire is a commonly used fixation device in orthopedics, little is known about the effects of fastening methods and configurations on the strength of wiring systems. Three sizes of stainless steel surgical wire were tested in noncyclic tensile loading. Load failure levels increased with enlarging wire diameter. Fastening twists were stronger than knots or the ASIF bend technique. The failure mode for twists was untwisting. More than two twists gave no additional strength to the system. Two commercial wire tightening devices gave stronger and more reproducible twists than did ordinary pliers. The addition of a tension equalizing loop opposite the fastening loop weakened the wire system by 10%-15%. The combination of two single wire loops was stronger than a continuous double loop of wire. The results from this study are intended to help the orthopedic surgeon optimize the use of wire.

  10. Up to 40 Gb/s wireless signal generation and demodulation in 75-110 GHz band using photonic techniques

    DEFF Research Database (Denmark)

    Sambaraju, R.; Zibar, Darko; Caballero Jambrina, Antonio

    2010-01-01

    Record wireless signal capacity of up to 40 Gb/s is demonstrated in the 75-110 GHz band. All-optical OFDM and photonic up-conversion are used for generation and digital coherent detection for demodulation....

  11. An X-ray scanner for wire chambers

    Science.gov (United States)

    Akesson, T.; Arik, E.; Assamagan, K.; Baker, K.; Benjamin, D.; Bertelsen, H.; Bytchkov, V.; Callahan, J.; Capeans-Garrido, M.; Catinaccio, A.; Cetin, A.; Cwetanski, P.; Danielsson, H.; Dittus, F.; Dolgoshein, B.; Dressnandt, N.; Ebenstein, W. L.; Eerola, P.; Farthouat, P.; Froidevaux, D.; Grichkevitch, Y.; Hajduk, Z.; Hansen, J. R.; Keener, P. K.; Kekelidze, G.; Konovalov, S.; Kowalski, T.; Kramarenko, V. A.; Kruger, K.; Lundberg, B.; Luehring, F.; Manara, A.; McFarlane, K.; Mitsou, V. A.; Morozov, S.; Muraviev, S.; Nadtochy, A.; Newcomer, F. M.; Olszowska, J.; Ogren, H.; Oh, S. H.; Peshekhonov, V.; Price, M.; Rembser, C.; Romaniouk, A.; Rust, D. R.; Schegelsky, V.; Sapinski, M.; Shmeleva, A.; Smirnov, S.; Smirnova, L. N.; Sosnovtsev, V.; Soutchkov, S.; Spiridenkov, E.; Tikhomirov, V.; VanBerg, R.; Vassilakopoulos, V.; Wang, C.; Williams, H. H.

    2003-07-01

    The techniques to measure the position of sense wires and field wires, the gas gain and the gas flow rate inside wire chambers using a collimated and filtered X-ray beam are reported. Specific examples are given using barrel modules of the Transition Radiation Tracker of the ATLAS experiment.

  12. The karyotype of Festucopsis serpentini (Poaceae Triticeae) from Albania studied by banding techniques and in situ hybridization

    DEFF Research Database (Denmark)

    Linde-Laursen, I.; Seberg, O.; Frederiksen, S.

    1996-01-01

    The karyotypes of two populations of Festucopsis serpentini (2n = 2x = 14) endemic to Albania were investigated in detail by Giemsa C- and N-banding, AgNO3 staining, and in situ hybridization with an rDNA probe. The complements consisted of 14 large chromosomes, 10 metacentric and 4 SAT-chromosom......The karyotypes of two populations of Festucopsis serpentini (2n = 2x = 14) endemic to Albania were investigated in detail by Giemsa C- and N-banding, AgNO3 staining, and in situ hybridization with an rDNA probe. The complements consisted of 14 large chromosomes, 10 metacentric and 4 SAT...... plants was only possible for the SAT-chromosomes. A comparison between the C-banded karyotypes of F. serpentini and Peridictyon sanctum supports their position in two genera....

  13. Comparison of the karyotypes ofPsathyrostachys juncea andP. huashanica (Poaceae) studied by banding techniques

    DEFF Research Database (Denmark)

    Linde-Laursen, Ib; Bothmer, R. von

    1986-01-01

    The karyotypes of P. juncea (Elymus junceus) and P. huashanica (both outbreeders) were investigated by Feulgen-staining and by C-, N-, and Ag-banding, based on a single plant in each case. Both species have 2n = 2x = 14 and large chromosomes, possibly a generic character. The karyotype of P. juncea....... The patterns of both taxa are polymorphic, supporting that both taxa are outbreeders. The karyotypic characters suggest that P. juncea is more closely related to P. fragilis than either is to P. huashanica. N-banding stains weakly. Silver nitrate staining demonstrates that nucleolus organizers of both species...

  14. Kirschner Wire Breakage during Removal Requiring Retrieval

    Directory of Open Access Journals (Sweden)

    Kai Yuen Wong

    2016-01-01

    Full Text Available Kirschner wires (K-wires are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his right middle finger. This open fracture was treated with K-wire fixation. Postoperatively, he developed a pin site infection with associated finger swelling. The K-wire broke during removal with the proximal piece completely retained in his middle phalanx. To minimise risk of osteomyelitis, the K-wire was removed with a novel surgical technique. He had full return of hand function. Intraoperative K-wire breakage has a reported rate of 0.1%. In our case, there was no obvious cause of breakage and the patient denied postoperative trauma. On the other hand, pin site infections are much more common with reported rates of up to 7% in the hand or wrist. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.

  15. Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2010-01-01

    decreasing from 19 nm (ε = 0) to 2 nm (ε = 3.7) in correspondence with the reduction in wire diameter. The deformation of the cementite is strongly related to plastic deformation in the ferrite, with coarse slip steps, shear bands and cracks in the cementite plates/particles observed parallel to either {110...... microscope observations show that cementite plates become increasingly aligned with the wire axis as the drawing strain is increased. Measurements in the transmission electron microscope show that the cementite deforms plastically during wire drawing , with the average thickness of the cementite plates...

  16. STATIC ANALYSIS OF STRESSES INDIUCED BY MATRIX BAND IN ROOT CANAL TREATED SECOND PREMOLARS MOD CAVITIES BY FINITE ELEMENTH TECHNIQUE

    Directory of Open Access Journals (Sweden)

    K KHOSRAVI

    2000-09-01

    Full Text Available Introduction. The purpose of this study is measurement the stresses due to matrix bond and their effect on fracture or crock formation in teeth and finally modifying in treatment methods of tooth. Methods. We use a second premolar that was as similar as measurements of wheelers studies. Au mod cavity prepared with buccolingual width 3mm while the roof of pulp chamber has been removed and gingival floor was 1mm higher than CEJ. CTS was prepared in three dimention: crolan, sigital and axial and then tooth model was made based on Nisall program. The forces due to matrix band measured by strain guage and then, this force based on finite element method applied on the prepared model. Results: Inall cases, stresses observed in tensile and shear from tensile stresses was mainly in cervical one third of buccal cups and shear stress was surronded cervical area of the tooth like as circle. The greatest amount of forces were localized in gingival floor in mesial area and in the enamel with increasing the depth and sidth of cavity. The amount of this stresses increased especially in increasing of depth. With increasing the width and depth cuspal displacment was observed especially in colossal on third which localized in buccal cusp. Discussion. Matrix band stresses mainly are destructive and cause fractures or at least crack formation in tooth. So its preffered to use thinner band in shorter time as much as possible. using of anatomic bands were prefeved.

  17. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  18. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  19. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. Ultra Wide X-Band Microwave Imaging of Concealed Weapons and Explosives Using 3D-SAR Technique

    OpenAIRE

    Millot, P.; Casadebaig, L

    2015-01-01

    International audience; In order to detect and image concealed weapons and explosives, an electromagnetic imaging tool with its related signal processing is presented. The aim is to penetrate clothes and to find personal-born weapons and explosives under clothes. The chosen UWB frequency range covers the whole X-band. The frequency range is justified after transmission measurements of numerous clothes that are dry or slightly wet. The apparatus and the 3D near-field SAR processor are describe...

  1. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  2. Comparison of subtransverse process wiring and sublaminar wiring in the treatment of idiopathic thoracic scoliosis.

    Science.gov (United States)

    Akmeşe, Ramazan; Kemal Us, Ali

    2013-04-01

    A retrospective study. The objectives of this study were to show the advantages of an alternative segmental spinal instrumentation technique, termed subtransverse process wiring, and compare it with a sublaminar wiring technique in the treatment of idiopathic thoracic scoliosis. High rates of neurological complications and the need for high experience limit the use of the sublaminar wiring technique, although it is an effective segmental spinal instrumentation technique in the treatment of scoliosis. This is the first study to correlate sublaminar wiring and subtransverse process wiring techniques clinically. In a retrospective study, 64 patients with idiopathic thoracic scoliosis were chosen randomly. Nineteen patients were treated with subtransverse process wires (group A), and 45 patients were treated with sublaminar wires (group B). The mean follow-up period was 50.9 months (25 to 90 mo) in group A and 57.9 months (26 to 108 mo) in group B. The average deformity correction was 26.5 degrees (52.9%) in group A and 28.9 degrees (54.1%) in group B. The average correction loss was 2.9 degrees (17.2%) in group A and 6.4 degrees (27%) in group B. None of the patients developed neurological complications in group A. In group B, 5 (11.1%) intraoperative dural tears, 4 (8.9%) neurological deficits, and 8 (14.4%) transient dysesthesia syndromes were seen. The average operation time was 3.6 hours (3 to 4 h) in group A and 4.9 hours (3.75 to 8 h) in group B. The average replacement of blood (erythrocyte suspension) was 2.9 U (2 to 5 U) in group A and 3.1 U (2 to 6 U) in group B. Sublaminar wiring is a time-consuming technique with high risks of neurological complications, whereas subtransverse process wiring is an easy and neurologically safe method, which maintains effective deformity correction and stability of the correction.

  3. Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures.

    Science.gov (United States)

    Tian, Yun; Zhou, Fang; Ji, Hongquan; Zhang, Zhishan; Guo, Yan

    2011-12-01

    Although the modified tension band technique (eg, tension band supplemented by longitudinal Kirschner wires) has long been the mainstay for fixation of transverse fractures of the patella, it has shortcomings, such as bad reduction, loosening of implants, and skin irritation. We conducted a retrospective comparison of the modified tension band technique and the titanium cable-cannulated screw tension band technique. We retrospectively reviewed 101 patients aged 22 to 85 years (mean, 56.6 years) with AO/OTA 34-C1 fractures (n = 68) and 34-C2 fractures (n = 33). Fifty-two patients were in the modified tension band group and 49 were in the titanium cable-cannulated screw tension band group. Followup was at least 1 year (range, 1-3 years). Comparison criteria were fracture reduction, fracture healing time, and the Iowa score for knee function. The titanium cable-cannulated screw tension band group showed improved fracture reduction, reduced healing time, and better Iowa score, compared with the modified tension band group. In the modified tension band group, eight patients experienced wire migration, three of these requiring a second operation. There were no complications in the titanium cable-cannulated screw tension band group. The titanium cable-cannulated screw tension band technique showed superior results and should be considered as an alternative method for treatment of transverse patellar fractures. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  4. In-line monitoring technique with visible light from 1.3 microm-band SHG module for optical access systems.

    Science.gov (United States)

    Kubo, Takahiro; Taniguchi, Tomohiro; Tadanaga, Osamu; Sakurai, Naoya; Kimura, Hideaki; Hadama, Hisaya; Asobe, Masaki

    2010-02-01

    We propose an in-line monitoring technique that uses 650 nm visible light for performing maintenance work on Fiber-to-the-home (FTTH) network quickly without the need for measuring skills or external devices. This technique is characterized by visible light (650 nm) generated by an SHG module from the 1.3 microm-band line signal. We fabricate a 1.3 microm-band quasi phase matched LiNbO(3) (QPM-LN) module, and the measure the 650 nm second harmonic (SH) power to test the proposed short-pulse modulation method. The results confirm the feasibility of the short-pulse modulation method with different peak factors (PFs) (1.0-7.3). We also examine the effect of short-pulse modulation on system performance at the optical receiver by measuring the bit error rate (BER) of received data (1.25 Gb/s). The BER is basically unaffected by the PF (1.0-5.5). This means that the proposed technique has little influence on data reception as regards PF (1.0-5.5).

  5. Surface Clutter Suppression Techniques Applied to P-band Multi-Channel SAR Ice Sounder Data from East Antarctica

    DEFF Research Database (Denmark)

    Lin, Chung-Chi; Bekaert, David; Gebert, Nicolas

    Radar ice sounding allows for the retrieval of ice depth and provides information on ba-sal topography, basal conditions, flow, and layering. In the prospect of a possible future satellite ice sounding mission, surface clutters are expected to severely hamper measurement of radar ech-oes from...... the depth due to the unfavourable observation geometry. Synthetic aperture radar (SAR) processing enables to attenuate surface clutters in the forward and backward directions, but not in the across-track directions. Thus, additional across-track clutter cancellation is a crucial step for extracting weaker...... subsurface radar echoes. ESA’s P-band POLarimetric Airborne Radar Ice Sounder (POLARIS), recently upgraded with a larger antenna of 4 m length, enables simultaneous reception of up to 4 sub-aperture channels in across-track. Laboratory of Electromagnetics and Acoustics of Swiss Fed. Institute of Tech...

  6. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  7. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  8. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  9. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  11. Investigation of grapevine photosynthesis using hyperspectral techniques and development of hyperspectral band ratio indices sensitive to photosynthesis.

    Science.gov (United States)

    Ozelkan, Emre; Karaman, Muhittin; Candar, Serkan; Coskun, Zafer; Ormeci, Cankut

    2015-01-01

    The photosynthetic rate of 9 different grapevines were analyzed with simultaneous photosynthesis and spectroradiometric measurements on 08.08.2012 (veraison) and 06.09.2012 (harvest). The wavelengths and spectral regions, which most properly express photosynthetic rate, were determined using correlation and regression analysis. In addition, hyperspectral band ratio (BR) indices sensitive to photosynthesis were developed using optimum band ratio (OBRA) method. The relation of BR results with photosynthesis values are presented with the correlation matrix maps created in this study. The examinations were performed for both specific dates (i.e., veraison and harvest) and also in aggregate (i.e., correlation between total spectra and photosynthesis data). For specific dates wavelength based analysis, the photosynthesis were best determined with -0.929 correlation coefficient (r) 609 nm of yellow region at veraison stage, and -0.870 at 641 nm of red region at harvest stage. For wavelength based aggregate analysis, 640 nm of red region was found to be correlated with 0.921 and -0.867 r values respectively and red edge (RE) (695 nm) was found to be correlated with -0.922 and -0.860 r values, respectively. When BR indices results were analyzed with photosynthetic values for specific dates, -0.987 r with R8../R, at veraison stage and -0.911 r with R696/R944 at harvest stage were found most correlated. For aggregate analysis of BR, common BR presenting great correlation with photosynthesis for both measurements was found to be R632/R971 with -0.974, -0.881 r values, respectively and other R610/R760 with -0.976, -0.879 r values. The final results of this study indicate that the proportion of RE region to a region with direct or indirect correlation with photosynthetic provides information about rate of photosynthesis. With the indices created in this study, the photosynthesis rate of vineyards can be determined using in-situ hyperspectral remote sensing. The findings of this

  12. Percutaneous cerclage wiring for the surgical treatment of displaced patella fractures.

    Science.gov (United States)

    Matsuo, Tomoji; Watari, Taiji; Naito, Kiyohito; Mogami, Atsuhiko; Kaneko, Kazuo; Obayashi, Osamu

    2014-04-01

    The patella plays an important role in the knee joint extension, and a patella fracture requires surgical treatment when it is accompanied by displacement of bone fragments and a joint surface gap. In patella fractures, there is disruption of the soft tissue structures that support the knee extension mechanism. We use a method of percutaneous cerclage wiring to fix the patella and include the peripatellar soft tissues in five patients. All cases were closed fractures, and the AO classification was type A in 1 and type C in 4. At a mean follow-up of 11.2 months, union was achieved in four cases with failure in one inferior pole fracture avulsion. There was no extensor lag noted in any patient, with mean flexion at 141° (120-160). As this percutaneous cerclage wiring method includes soft tissue approximation in the wiring, it may be especially suitable for comminuted fractures for which classic tension band wiring techniques cannot be used. We employed this procedure to atraumatically manipulate peripatellar soft tissues together with the fracture fragments in order to obtain optimal restoration of continuity of the extensor mechanism.

  13. Automating wiring formboard design

    NARCIS (Netherlands)

    Van den Berg, T.

    2013-01-01

    Increase in aircraft wiring complexity call for manufacturing design improvements to reduce cost and lead-time. To achieve such improvements, a joint research project was performed by the Flight Performance and Propulsion (FPP) group and Fokker Elmo BV, the second largest aircraft wiring harness

  14. Josephson junction arrays and superconducting wire networks

    International Nuclear Information System (INIS)

    Lobb, C.J.

    1992-01-01

    Techniques used to fabricate integrated circuits make it possible to construct superconducting networks containing as many as 10 6 wires or Josephson junctions. Such networks undergo phase transitions from resistive high-temperature states to ordered low-resistance low-temperature states. The nature of the phase transition depends strongly on controllable parameters such as the strength of the superconductivity in each wire or junction and the external magnetic field. This paper will review the physics of these phase transitions, starting with the simplest zero-magnetic field case. This leads to a Kosterlitz-Thouless transition when the junctions or wires are weak, and a simple mean-field fransition when the junctions or wires are strong. Rich behavior, resulting from frustration, occurs in the presence of a magnetic field. (orig.)

  15. Remote sensing estimation of the total phosphorus concentration in a large lake using band combinations and regional multivariate statistical modeling techniques.

    Science.gov (United States)

    Gao, Yongnian; Gao, Junfeng; Yin, Hongbin; Liu, Chuansheng; Xia, Ting; Wang, Jing; Huang, Qi

    2015-03-15

    Remote sensing has been widely used for ater quality monitoring, but most of these monitoring studies have only focused on a few water quality variables, such as chlorophyll-a, turbidity, and total suspended solids, which have typically been considered optically active variables. Remote sensing presents a challenge in estimating the phosphorus concentration in water. The total phosphorus (TP) in lakes has been estimated from remotely sensed observations, primarily using the simple individual band ratio or their natural logarithm and the statistical regression method based on the field TP data and the spectral reflectance. In this study, we investigated the possibility of establishing a spatial modeling scheme to estimate the TP concentration of a large lake from multi-spectral satellite imagery using band combinations and regional multivariate statistical modeling techniques, and we tested the applicability of the spatial modeling scheme. The results showed that HJ-1A CCD multi-spectral satellite imagery can be used to estimate the TP concentration in a lake. The correlation and regression analysis showed a highly significant positive relationship between the TP concentration and certain remotely sensed combination variables. The proposed modeling scheme had a higher accuracy for the TP concentration estimation in the large lake compared with the traditional individual band ratio method and the whole-lake scale regression-modeling scheme. The TP concentration values showed a clear spatial variability and were high in western Lake Chaohu and relatively low in eastern Lake Chaohu. The northernmost portion, the northeastern coastal zone and the southeastern portion of western Lake Chaohu had the highest TP concentrations, and the other regions had the lowest TP concentration values, except for the coastal zone of eastern Lake Chaohu. These results strongly suggested that the proposed modeling scheme, i.e., the band combinations and the regional multivariate

  16. The Zonation of Abration Speed Characteristics and its Handling Technique of Jalinbar of North Bengkulu as Vital Band Transportation

    Directory of Open Access Journals (Sweden)

    Suwarsono Suwarsono

    2011-09-01

    Full Text Available Jalinbar Bengkulu is a vital infrastructure for traffic service, goods, agriculture products, mining, plantation and oils distribution. Abration due to scour of seawater often make these roads jammed and discrupts the peoples economy movement. The aims  of this research was to investigate the abration speed of all segment of Jalinbar. The research method was a combination of two methods: A determination of swash energy of sea water using photometer and determination of rocks binding energy using douche method. The result shows that the maximum abration speed was in north area of Bengkulu beach, occurred in Air Dikit I, Urai I, and Urai II. The abration speed was 2-2,5 m/year. The other abration speed occurred in Air Petai, Palik, Pekik Nyaring in 0,5-1 m/year. On the other hand, Pasar Ketahun, Selolong, Air Serangai I, Air Serangai II, Kota Agung, Ulu Danau and Harapan was 1-2 m/year. The handling technique of all abration location of Jalinbar Bengkulu, north area using groin and jetty, except for Air Dikit and Urai I using jetty. Beside that, the handling technique for Air Serangai II using a combination of groin, jetty, and gabions.

  17. Electronic transport in Si:P δ-doped wires

    DEFF Research Database (Denmark)

    Smith, J. S.; Drumm, D. W.; Budi, Akin

    2015-01-01

    Despite the importance of Si:P δ-doped wires for modern nanoelectronics, there are currently no computational models of electron transport in these devices. In this paper we present a nonequilibrium Green’s function model for electronic transport in a δ-doped wire, which is described by a tight......-binding Hamiltonian matrix within a single-band effective-mass approximation. We use this transport model to calculate the current-voltage characteristics of a number of δ-doped wires, achieving good agreement with experiment. To motivate our transport model we have performed density-functional calculations...... for a variety of δ-doped wires, each with different donor configurations. These calculations also allow us to accurately define the electronic extent of a δ-doped wire, which we find to be at least 4.6 nm....

  18. Heat Transfer Analysis in Wire Bundles for Aerospace Vehicles

    Science.gov (United States)

    Rickman, S. L.; Iamello, C. J.

    2016-01-01

    Design of wiring for aerospace vehicles relies on an understanding of "ampacity" which refers to the current carrying capacity of wires, either, individually or in wire bundles. Designers rely on standards to derate allowable current flow to prevent exceedance of wire temperature limits due to resistive heat dissipation within the wires or wire bundles. These standards often add considerable margin and are based on empirical data. Commercial providers are taking an aggressive approach to wire sizing which challenges the conventional wisdom of the established standards. Thermal modelling of wire bundles may offer significant mass reduction in a system if the technique can be generalized to produce reliable temperature predictions for arbitrary bundle configurations. Thermal analysis has been applied to the problem of wire bundles wherein any or all of the wires within the bundle may carry current. Wire bundles present analytical challenges because the heat transfer path from conductors internal to the bundle is tortuous, relying on internal radiation and thermal interface conductance to move the heat from within the bundle to the external jacket where it can be carried away by convective and radiative heat transfer. The problem is further complicated by the dependence of wire electrical resistivity on temperature. Reduced heat transfer out of the bundle leads to higher conductor temperatures and, hence, increased resistive heat dissipation. Development of a generalized wire bundle thermal model is presented and compared with test data. The steady state heat balance for a single wire is derived and extended to the bundle configuration. The generalized model includes the effects of temperature varying resistance, internal radiation and thermal interface conductance, external radiation and temperature varying convective relief from the free surface. The sensitivity of the response to uncertainties in key model parameters is explored using Monte Carlo analysis.

  19. The effect of thermal annealing on the optical band gap of cadmium sulphide thin films, prepared by the chemical bath deposition technique

    International Nuclear Information System (INIS)

    Ampong, F. K.; Boakye, F.; Asare Donkor, N. K.

    2010-01-01

    Cadmium sulphide thin films have been prepared by the chemical bath deposition technique (ph 11, 70 degree centigrade). Two different sets of films were prepared under varied conditions and concentrations of their ions sources (Cd 2+ from cadmium nitrate, S 2- from thiourea) and Na 2 EDTA as a complexing agent. A UV mini-Schimazu UV-VIS Spectrophotometer was used to determine the optical absorbance of the films as a function of wavelength at room temperature over the wavelength range 200 - 600 nm. The samples were then thermally annealed for thirty minutes, at temperatures of 100 degree centigrade, and 200 degree centigrade, after which the absorbance of the films were again recorded. The band gap values obtained for the sample with 0.5 M CdS as deposited, annealed at 100 degree centigrade and 200 degree centigrade were 2.1 eV, 2.2 eV and 2.3 eV respectively. Whilst the values obtained for the sample 0.15 CdS as deposited, annealed at 100 degree centigrade and annealed at 200 degree centigrade were 2.0 eV, 2.01 eV and 2.02 eV respectively. The increase in band gap with annealing temperature might be attributed to the improvement in crystallinity in the films. (au)

  20. Bacterial community structure associated with white band disease in the elkhorn coral Acropora palmata determined using culture-independent 16S rRNA techniques.

    Science.gov (United States)

    Pantos, Olga; Bythell, John C

    2006-03-23

    Culture-independent molecular (16S ribosomal RNA) techniques showed distinct differences in bacterial communities associated with white band disease (WBD) Type I and healthy elkhorn coral Acropora palmata. Differences were apparent at all levels, with a greater diversity present in tissues of diseased colonies. The bacterial community associated with remote, non-diseased coral was distinct from the apparently healthy tissues of infected corals several cm from the disease lesion. This demonstrates a whole-organism effect from what appears to be a localised disease lesion, an effect that has also been recently demonstrated in white plague-like disease in star coral Montastraea annularis. The pattern of bacterial community structure changes was similar to that recently demonstrated for white plague-like disease and black band disease. Some of the changes are likely to be explained by the colonisation of dead and degrading tissues by a micro-heterotroph community adapted to the decomposition of coral tissues. However, specific ribosomal types that are absent from healthy tissues appear consistently in all samples of each of the diseases. These ribotypes are closely related members of a group of alpha-proteobacteria that cause disease, notably juvenile oyster disease, in other marine organisms. It is clearly important that members of this group are isolated for challenge experiments to determine their role in the diseases.

  1. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  2. ZEBRAFISH CHROMOSOME-BANDING

    NARCIS (Netherlands)

    PIJNACKER, LP; FERWERDA, MA

    1995-01-01

    Banding techniques were carried out on metaphase chromosomes of zebrafish (Danio rerio) embryos. The karyotypes with the longest chromosomes consist of 12 metacentrics, 26 submetacentrics, and 12 subtelocentrics (2n = 50). All centromeres are C-band positive. Eight chromosomes have a pericentric

  3. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  5. Cryogenic Pressure Seal for Wires

    Science.gov (United States)

    Ciana, J. J.

    1984-01-01

    High-pressure-seal formed by forcing polyurethane into space surrounding wire or cable in special fitting. Wire or cable routed through fitting then through a tightly fitting cap. Wire insulation left intact. Cap filled with sealant and forced onto the fitting: this pushes sealant into fitting so it seals wire or cable in fitting as well as in cap.

  6. Early and late outcome after single step dilatational tracheostomy versus the guide wire dilating forceps technique: a prospective randomized clinical trial

    NARCIS (Netherlands)

    Fikkers, B.G.; Staatsen, M; Hoogen, F.J.A. van den; Hoeven, J.G. van der

    2011-01-01

    PURPOSE: Percutaneous tracheostomy is frequently performed in long-term ventilated patients in the intensive care unit (ICU). Unfortunately, despite many years of experience, the optimal technique is still unknown, especially considering the occurrence of late complications. The purpose of this

  7. Closed reduction and percutaneus Kirschner wire fixation for the treatment of dislocated calcaneal fractures: surgical technique, complications, clinical and radiological results after 2–10 years

    Science.gov (United States)

    Sauer, B.; Degreif, J.; Walde, H.-J.

    2008-01-01

    Introduction To reduce complications, a minimally invasive technique for the treatment of dislocated intraarticular fractures of the calcaneus was used. Therefore previously described closed reduction and internal fixation techniques were combined and modified. Materials and methods Sixty-seven out of 92 calcaneal fractures could be retrospectively evaluated with an average follow-up time of 5.7 years (minimum 2–10 years follow-up). For radiographic evaluation, plain radiographs and CT scans were obtained. The Zwipp score was used for clinical evaluation. Sanders type II, III and IV fractures were diagnosed. Results Length of surgery averaged 61 min (range 20–175 min). The incidence of subtalar arthritis was correlated to the severity of fracture. Böhler’s angle was restored in 70.1% (47 of 67) of the cases. On the last follow-up evaluation the average Zwipp score was 130 points (range 48–186 points). The majority (77.7%) of patients were content with their treatment result. The rate of significant complications was 6.5%. Discussion Compared to open techniques the presented minimally invasive technique showed comparable results with a low rate of serious complications and is a viable alternative for the treatment of intraarticular, dislocated calcaneal fractures. PMID:18309507

  8. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  9. A KBE Application for Automatic Aircraft Wire Harness Routing

    NARCIS (Netherlands)

    Zhu, Z.; Van Tooren, M.J.L.; La Rocca, G.

    2012-01-01

    Wire harness design is an increasingly complex task. Knowledge Based Engineering (KBE) and optimization techniques can be used to support designers in handling this complexity. The wire harness design process can be divided in three main parts, namely electrical design, configuration design and

  10. Investigation of method for Stainless Steel Welding Wire as a Replacement for Arc Wire Comsumables

    Directory of Open Access Journals (Sweden)

    Koiprasert, H.

    2005-01-01

    Full Text Available Arc spraying as a coating method is being employed in various industrial applications as a part of maintenance service, and also as a surface engineering technique for many machine parts and components. The major cost in producing the arc spray coating is, however, based on the cost of the arc wire comsumables. This project was carried out to investigate the use of the commercially-available gas metal arc welding wire (GMAW wire as a cheaper alternative to the special-purpose arc wire comsumables. The wire material chosen for this early study is the 316L stainless steel, due to its popularity in many applications as a built-up coating for worn parts. The physical properties of the coatings produced from the two sets of 316L stainless steel wire were determined to be different in the percentage of porosity and the oxide content. The mechanical properties, including the tensile bond strength and the wear rate of the coatings produced from the two types of sprayed wire, were also different. This will, in turn, result in a slight difference in the performance of thecoatings.

  11. A prism based magnifying hyperlens with broad-band imaging

    DEFF Research Database (Denmark)

    Habib, Md. Samiul; Stefani, Alessio; Atakaramians, Shaghik

    2017-01-01

    Magnification in metamaterial hyperlenses has been demonstrated using curved geometries or tapered devices, at frequencies ranging from the microwave to the ultraviolet spectrum. One of the main issues of such hyperlenses is the difficulty in manufacturing. In this letter, we numerically and expe......Magnification in metamaterial hyperlenses has been demonstrated using curved geometries or tapered devices, at frequencies ranging from the microwave to the ultraviolet spectrum. One of the main issues of such hyperlenses is the difficulty in manufacturing. In this letter, we numerically...... frequency dependent artefacts, a priori limiting the use of the device for broad-band imaging. We identify the main source of image aberration as the reflections supported by the wire medium and also show that even the weaker reflections severely affect the imaging quality. In order to correct...... for the reflections, we devise a filtering technique equivalent to spatially variable time gating so that ultra-broad band imaging is achieved....

  12. A High-Temperature Transient Hot-Wire Thermal Conductivity Apparatus for Fluids

    OpenAIRE

    Perkins, R. A.; Roder, H. M.; Nieto de Castro, C. A.

    1991-01-01

    A new apparatus for measuring both the thermal conductivity and thermal diffusivity of fluids at temperatures from 220 to 775 K at pressures to 70 MPa is described. The instrument is based on the step-power-forced transient hot-wire technique. Two hot wires are arranged in different arms of a Wheatstone bridge such that the response of the shorter compensating wire is subtracted from the response of the primary wire. Both hot wires are 12.7 ?m diameter platinum wire and are simultaneously use...

  13. High capacity wireless data links in the W-band using hybrid photonics-electronic techniques for signal generation and detection

    DEFF Research Database (Denmark)

    Vegas Olmos, Juan José; Tafur Monroy, Idelfonso

    2014-01-01

    , is seeding the need to use bands located at the millimeter-wave region (30–300 GHz), mainly because of its inherent broadband nature. In our lab, we have conducted extensive research on high-speed photonic-wireless links in the V-band (50–75GHz) and the W-band (75–110GHz). In this paper, we will present our...... latest findings and experimental results on the W-band, specifically on its 81–86GHz sub-band. These include photonic generation of millimeter-wave carriers and transmission performance of broadband signals on different types of fibers and span lengths....

  14. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

    Science.gov (United States)

    Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2015-08-01

    Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  15. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    You Na Oh

    2015-08-01

    Full Text Available Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578, major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99, minor wound complications (3.6% vs. 2.0%, p=0.279, or mediastinitis (0.8% vs. 1.0%, p=1.00. Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068. Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  16. Dorgan's lateral cross-wiring of supracondylar fractures of the humerus in children: A retrospective review.

    LENUS (Irish Health Repository)

    Queally, Joseph M

    2010-06-01

    The currently accepted treatment for displaced supracondylar humeral fractures in children is closed reduction and fixation with percutaneous Kirschner wires. The purpose of this study was to retrospectively review a novel cross-wiring technique where the cross-wire configuration is achieved solely from the lateral side, thereby reducing the risk of ulnar nerve injury.

  17. Tratamento cirúrgico de fraturas em martelo por bloqueio da extensão com fio de Kirschner Surgical treatment of mallet fractures with the extension block Kirschner wire technique

    Directory of Open Access Journals (Sweden)

    Metin Uzun

    2012-01-01

    Full Text Available OBJETIVO: Avaliar a eficácia do tratamento da fratura em martelo, pelo método de Ishiguro de bloqueio de extensão com fio de Kirschner. MÉTODOS: Trinta e oito pacientes foram tratados prospectivamente. O acompanhamento médio foi 18 meses e todos os pacientes foram avaliados radiológica e clinicamente, de acordo com os critérios de Crawford. RESULTADOS: A união da fratura foi obtida em todos os pacientes. Os resultados alcançados foram satisfatórios em 34 casos e não satisfatórios em quatro casos. CONCLUSÃO: Consideramos que a técnica de bloqueio de extensão é segura e eficaz e pode ser usada em todas as fraturas em martelo. Nível de Evidência IV, Série de CasosOBJECTIVE: To evaluate the effectiveness of treating the mallet fracture with the Ishiguro extension block Kirschner wire method. METHODS: Thirty-eight patients were treated prospectively. The mean follow-up was 18 months and all patients were evaluated radiologically and clinically according to Crawford’s criteria. RESULTS: Union was obtained in all patients. The results obtained were satisfactory in 34 cases and unsatisfactory in four cases. CONCLUSION: We consider the extension block technique a safe and effective method that can be used in all mallet fractures. Level of Evidence IV, Case Series.

  18. Nonsurgical correction of a severe anterior deep overbite accompanied by a gummy smile and posterior scissor bite using a miniscrew-assisted straight-wire technique in an adult high-angle case.

    Science.gov (United States)

    Wang, Xue-Dong; Zhang, Jie-Ni; Liu, Da-Wei; Lei, Fei-Fei; Zhou, Yan-Heng

    2016-07-01

    In the present report, we describe the successful use of miniscrews to achieve vertical control in combination with the conventional sliding MBT™ straight-wire technique for the treatment of a 26-year-old Chinese woman with a very high mandibular plane angle, deep overbite, retrognathic mandible with backward rotation, prognathic maxilla, and gummy smile. The patient exhibited skeletal Class II malocclusion. Orthodontic miniscrews were placed in the maxillary anterior and posterior segments to provide rigid anchorage and vertical control through intrusion of the incisors and molars. Intrusion and torque control of the maxillary incisors relieved the deep overbite and corrected the gummy smile, while intrusion of the maxillary molars aided in counterclockwise rotation of the mandibular plane, which consequently resulted in an improved facial profile. After 3.5 years of retention, we observed a stable, well-aligned dentition with ideal intercuspation and more harmonious facial contours. Thus, we were able to achieve a satisfactory occlusion, a significantly improved facial profile, and an attractive smile for this patient. The findings from this case suggest that nonsurgical correction using miniscrew anchorage is an effective approach for camouflage treatment of high-angle cases with skeletal Class II malocclusion.

  19. Metallurgical investigation of wire breakage of tyre bead grade

    Directory of Open Access Journals (Sweden)

    Piyas Palit

    2015-10-01

    Full Text Available Tyre bead grade wire is used for tyre making application. The wire is used as reinforcement inside the polymer of tyre. The wire is available in different size/section such as 1.6–0.80 mm thin Cu coated wire. During tyre making operation at tyre manufacturer company, wire failed frequently. In this present study, different broken/defective wire samples were collected from wire mill for detailed investigation of the defect. The natures of the defects were localized and similar in nature. The fracture surface was of finger nail type. Crow feet like defects including button like surface abnormalities were also observed on the broken wire samples. The defect was studied at different directions under microscope. Different advanced metallographic techniques have been used for detail investigation. The analysis revealed that, white layer of surface martensite was formed and it caused the final breakage of wire. In this present study we have also discussed about the possible reason for the formation of such kind of surface martensite (hard-phase.

  20. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  1. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  2. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  3. [Intramedullary osteosynthesis of distal metacarpal fractures with curved wires].

    Science.gov (United States)

    Schlageter, M; Winkel, R; Porcher, R; Haas, H G

    1997-07-01

    When intramedullary pinning is used to treat metacarpal fractures, as recently described by Förstner (1994) and Foucher (1995), the closed reduction technique developed by Jahss (1938) is applied in the same way as for conservative fracture treatment. It is not always possible to achieve complete anatomical reduction using this closed technique. The intramedullary pinning technique, that we have applied since 1989, involves a Kirschner wire which is bent at one end. Apart from reducing the fracture, the pre-set Kirschner wire serves as a butressing internal fixator. The elastic clamping of the wire acts as an internal wire spring splint, permitting early mobilisation. We have operated on 62 metacarpal fractures using the above-mentioned technique over a period of 6 years until 1995. Anatomic reduction was realized in 50 of 62 fractures. In the follow-up of 32 fractures, we noticed four complications: one infection, two paraesthesias, and one non-union.

  4. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...

  5. Application of Synthetic Storm Technique for Diurnal and Seasonal Variation of Slant Path Ka-Band Rain Attenuation Time Series over a Subtropical Location in South Africa

    Directory of Open Access Journals (Sweden)

    J. S. Ojo

    2015-01-01

    Full Text Available As technology advances and more demands are on satellite services, rain-induced attenuation still creates one of the most damaging effects of the atmosphere on the quality of radio communication signals, especially those operating above 10 GHz. System designers therefore require statistical information on rain-induced attenuation over the coverage area in order to determine the appropriate transmitter and receiver characteristics to be adopted. This paper presents results on the time-varying rain characterization and diurnal variation of slant path rain attenuation in the Ka-band frequency simulated with synthetic storm techniques over a subtropical location in South Africa using 10-year rain rate time-series data. The analysis is based on the CDF of one-minute rain rate; time-series seasonal variation of rain rate observed over four time intervals: 00:00–06:00, 06:00–12:00, 12:00–18:00, and 18:00–24:00; diurnal fades margin; and diurnal variation of rain attenuation. Comparison was also made between the synthesized values and measured attenuation data. The predicted statistics are in good agreement with those obtained from the propagation beacon measurement in the area. The overall results will be needed for an acceptable planning that can effectively reduce the fade margin to a very low value for an optimum data communication over this area.

  6. A resonance measuring wire tension monitor for high-energy physics

    International Nuclear Information System (INIS)

    Durkin, L.S.; Fisher, D.; Lennous, P.; Ling, T.Y.; Rush, C.

    1995-01-01

    The Ohio State group has built a device to automatically measure the wire tension on the sense wire in SDC (Solenoidal Detector Collaboration) barrel muon drift tubes using resonance techniques. The SDC experiment was part of the now canceled SSC (Superconducting Super Collider) project. The design, construction, and operation of a wire tension monitor is presented. The technique used is unique in that the electric force is used to excite the wire into harmonic resonance. The amplitude of the wire is in turn monitored using the variation of the oscillating wire's capacitance measured by a resonance circuit. Finally, the resonance is found electronically using phase lock loop techniques. Wire tension is measured to an accuracy of 0.3% with this device

  7. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  8. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    CFAR Constant False Alarm Rate CWIE Command Wire-Improvised Explosive Device EMI Electromagnetic Induction GPR Ground Penetrating Radar...this, some type of constant false alarm rate ( CFAR ) receiver is required. CFAR automatically raises the threshold level to keep clutter echoes and

  9. Transport in quantum wires

    Indian Academy of Sciences (India)

    Transport in quantum wires. SIDDHARTHA LAL, SUMATHI RAO£ and DIPTIMAN SEN. Centre for Theoretical Studies, Indian Institute of Science, Bangalore 560 012, India. £ Harish-chandra Research Institute, Chhatnag Road, Jhusi, Allahabad 211 019, India. Abstract. With a brief introduction to one-dimensional channels ...

  10. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  11. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...... in the structure and crystallography when a randomly oriented cementite structure in a patented wire during wire drawing is transformed into a lamellar structure parallel to the drawing axis. Changes in the interlamellar spacing and in the misorientation angle along and across the ferrite lamellae show significant...... through-diameter variations in wires drawn to large strains P 1.5. The structural evolution is hierarchical as the structural variations have their cause in a different macroscopic orientation of the cementite in the initial (patented) structure with respect to the wire axis. The through...

  12. Single Wire Detector Performance Over One Year of Operation

    CERN Document Server

    Hervas Aguilar, David Alberto

    2014-01-01

    Abstract When ionizing radiation passes through gas chambers in single wire detectors gas molecules separate into ions and electrons. By applying a strong localized electric field near the single wire an avalanche of electrons is created and it can be collected. The current produced in the wire is then proportional to the energy of the particle detected. Nevertheless, many factors can contribute to detector aging effects which are visible in a loss of gain caused by deposition of contaminants on the collecting wire. This study consists on novel data analysis techniques used to process large amounts of data produced by two simultaneously running single wire detectors. Aging effects are analyzed while environmental fluctuations are corrected for. A series of scripts carry out data filtering, data matching, corrections, and finally trend plotting by using ROOT’s extensive libraries developed at CERN.

  13. Numerical model for electrical explosion of copper wires in water

    Science.gov (United States)

    Chung, Kyoung-Jae; Lee, Kern; Hwang, Y. S.; Kim, Deok-Kyu

    2016-11-01

    This paper presents a simple but quite accurate numerical model for analyzing electrical explosion of copper wires in water. The numerical model solves a circuit equation coupled with one-dimensional magneto-hydrodynamic (MHD) equations with the help of appropriate wide-range equation of state (EOS) and electrical conductivity for copper. The MHD equations are formulated in a Lagrangian form to identify the interface between the wire and surrounding water clearly. A quotidian EOS (QEOS) that is known as the simplest form of EOS is utilized to build wide-range EOS for copper. In the QEOS, we consider the liquid-vapor phase transition, which is critical in analyzing the wire explosion system. For the electrical conductivity of copper, a semi-empirical set of equations covering from solid state to partially ionized plasma state are employed. Experimental validation has been performed with copper wires of various diameters, which are exploded by a microsecond timescale pulsed capacitive discharge. The simulation results show excellent agreements with the experimental results in terms of temporal motions of a plasma channel boundary and a shock front as well as current and voltage waveforms. It is found that the wire explodes (vaporizes) along the liquid branch of a binodal curve irrespective of wire dimension and operating voltage. After the explosion, the wire becomes a plasma state right away or after the current pause (dwell), depending on the operating conditions. It is worth noting that such a peculiar characteristic of wire explosion, i.e., current pause and restrike, is well simulated with the present numerical model. In particular, it is shown that the wire cools down along the vapor branch of the binodal curve during the current dwell, due to a significant difference of thermodynamic characteristics across the binodal curve. The influence of radiation for studying nonideal plasmas with a wire explosion technique and a physical process for shock wave formation

  14. Fluorescent silver nanoparticles via exploding wire technique

    Indian Academy of Sciences (India)

    The absorption spectrum of the aqueous solution of silver nanoparticles showed the appearance of a broad surface plasmon resonance (SPR) peak centered at a wavelength of 390 nm. The theoretically generated. SPR peak seems to be in good agreement with the experimental one. Strong green fluores- cence emission ...

  15. Fluorescent silver nanoparticles via exploding wire technique

    Indian Academy of Sciences (India)

    P Sen, J Ghosh, Abdullah Alqudami, P Kumar and Vandana, Indian patent applied for international patent under the patent convention treaty (Paris) applied for (2003). [7] H Hovel, S Fritz, A Hilger, U Kreibig and M Vollmer, Phys. Rev. B48, 18178 (1993). [8] P B Johnson and R W Christy, Phys. Rev. B6, 4370 (1972).

  16. Control of flow past a circular cylinder via a spanwise surface wire: effect of the wire scale

    Energy Technology Data Exchange (ETDEWEB)

    Ekmekci, Alis [University of Toronto Institute for Aerospace Studies, Toronto, ON (Canada); Rockwell, Donald [Lehigh University, Department of Mechanical Engineering, Bethlehem, PA (United States)

    2011-09-15

    Flow phenomena induced by a single spanwise wire on the surface of a circular cylinder are investigated via a cinema technique of particle image velocimetry (PIV). The primary aim of this investigation is to assess the effect of the wire scale. To this end, consideration is given to wires with different diameters that are 0.5, 1.2, and 2.9% of the cylinder diameter. The Reynolds number has a subcritical value of 10,000. Compared to the thickness of the unperturbed boundary layer developing around the cylinder between 5 and 75 from the forward stagnation point, the former two wires have smaller scales and the latter has a larger scale. Two angular locations of the wire, defined with respect to the forward stagnation point of the cylinder, are found to be critical. When the wire is located at these critical angles, either the most significant extension or the contraction of the time-mean separation bubble occurs in the near wake. These critical angles depend on the wire scale: the smaller the wire, the larger the critical angle. The small-scale and large-scale wires that have diameters of 1.2 and 2.9% of the cylinder diameter induce bistable shear-layer oscillations between different separation modes when placed at their respective critical angles corresponding to maximum extension of the near-wake bubble. These oscillations have irregular time intervals that are much longer than the time scale associated with the classical Karman instability. Moreover, the large-scale wire can either significantly attenuate or intensify the Karman mode of vortex shedding at the critical states; in contrast, the small-scale wires do not notably alter the strength of the Karman instability. (orig.)

  17. Dental Arch Wire

    Science.gov (United States)

    1979-01-01

    Straightening teeth is an arduous process requiring months, often years, of applying corrective pressure by means of arch wires-better known as brace-which may have to be changed several times in the course of treatment. A new method has been developed by Dr. George Andreasen, orthodontist and dental scientist at the University of Iowa. The key is a new type of arch wire material, called Nitinol, with exceptional elasticity which helps reduce the required number of brace changes. An alloy of nickel and titanium, Nitinol was originally developed for aerospace applications by the Naval Ordnance Laboratory, now the Naval Surface Weapons Laboratory, White Oaks, Maryland. NASA subsequently conducted additional research on the properties of Nitinol and on procedures for processing the metal.

  18. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  19. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  20. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  1. Evaluation of multilayer printed wiring boards by metallographic techniques: An illustrated guide to the preparation and inspection of plated-through hole test coupons based on the requirements of Mil-P-55110D

    Science.gov (United States)

    Jellison, J.

    1986-01-01

    This work is an illustrated handbook containing the rationale and procedure for the evaluation of multilayer printed wiring board construction integrity with respect to plated-through holes in accordance with the requirements of MIL-P-55110D, Printed Wiring Boards. It is intended as a practical aid for those concerned with determining the construction integrity of multilayer boards for high reliability applications. Photomicrographs of cross sectioned holes illustrate defect types, acceptable and unacceptable conditions, and methods of measurement. A procedure for specimen preparation is given, and appropriate paragraphs of the military specification are included and explained.

  2. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. (Institute for Energy Technology (IFE) (Norway))

    2009-07-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  3. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.

    2009-07-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  4. Measurement of the saturation magnetostriction constant of amorphous wire

    International Nuclear Information System (INIS)

    Mitra, A.; Vazquez, M.

    1990-01-01

    Measurement of the magnetostriction constant of amorphous wire by conventional techniques is very difficult because of its small diameter. However, accurate determination of the magnetostriction constant is important in the study of amorphous wires. Here the saturation magnetostriction constant (λ s ) for a low-magnetostriction amorphous wire of nominal composition (Fe 6.3 Co 92.7 Nb 1 ) 77.5 Si 7.5 B 15 has been determined by means of the small-angle magnetization-rotation method. λ s has been evaluated to be 2.1x10 -7 for its as-received state. The dependence of thermal treatment is also reported

  5. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  6. Tuning the Electrical Conductivity of Nanotube-Encapsulated Metallocene Wires

    Science.gov (United States)

    García-Suárez, Víctor M.; Ferrer, Jaime; Lambert, Colin J.

    2006-03-01

    We analyze a new family of carbon nanotube-based molecular wires, formed by encapsulating metallocene molecules inside the nanotubes. Our simulations, which are based on a combination of nonequilibrium Green function techniques and density functional theory, indicate that these wires can be engineered to exhibit desirable magnetotransport effects for use in spintronics devices. The proposed structures should also be resilient to room-temperature fluctuations, and are expected to have a high yield.

  7. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  8. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  9. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  10. Epitaxial semiconductor quantum wires.

    Science.gov (United States)

    Wu, J; Chen, Y H; Wang, Z G

    2008-07-01

    The investigation on the direct epitaxial quantum wires (QWR) using MBE or MOCVD has been persuited for more than two decades, more lengthy in history as compared with its quantum dot counterpart. Up to now, QWRs with various structural configurations have been produced with different growth methods. This is a reviewing article consisting mainly of two parts. The first part discusses QWRs of various configurations, together with laser devices based on them, in terms of the two growth mechanisms, self-ordering and self-assembling. The second part gives a brief review of the electrical and optical properties of QWRs.

  11. 46 CFR 111.60-11 - Wire.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be...

  12. Size-dependent and intra-band photoluminescence of NiS2 nano-alloys synthesized by microwave assisted hydrothermal technique

    CSIR Research Space (South Africa)

    Linganiso, C

    2013-03-01

    Full Text Available for the uncapped nanostructures and 9 nmwas obtained for the capped nanostructures estimated using the Scherrer equation. Unexpected ultra-violet (UV) emission as well as near infrared (IR) emissions were attributed to intra-band energy state transitions that occur...

  13. Extensive polymorphism and chromosomal characteristics of ribosomal DNA in a loach fish, Cobitis vardarensis (Ostariophysi, Cobitidae) detected by different banding techniques and fluorescence in situ hybridization (FISH)

    Czech Academy of Sciences Publication Activity Database

    Rábová, Marie; Ráb, Petr; Ozouf-Costaz, C.

    2001-01-01

    Roč. 111, - (2001), s. 413-422 ISSN 0016-6707 R&D Projects: GA ČR GA206/00/0668; GA AV ČR IAA6045704; GA AV ČR KSK6005114 Keywords : chromosome banding * cytotaxonomy * fish Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.916, year: 2001

  14. Effect of band offset on carrier transport and infrared detection in InP quantum dots/Si nano-heterojunction grown by metalorganic chemical vapor deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Halder, Nripendra N. [Advanced Technology Development Centre, Indian Institute of Technology, Kharagpur 721 302 (India); Biswas, Pranab; Nagabhushan, B.; Banerji, P., E-mail: pallab@matsc.iitkgp.ernet.in [Materials Science Centre, Indian Institute of Technology, Kharagpur 721 302 (India); Kundu, Souvik [School of Electrical Engineering and Computer Science, Oregon State University, 1148 Kelley Engineering Center, Corvallis, Oregon 97331-5501 (United States); Biswas, D. [Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology, Kharagpur 721 302 (India)

    2014-05-28

    Epitaxy of III-V semiconductors on Si gets recent interest for next generation system on heterogeneous chip on wafer. The understanding of band offset is thus necessary for describing the charge transport phenomenon in these heterojunctions. In this work, x-ray photoemission spectroscopy has been used to determine the band offsets in a heterojunction made of InP quantum dots on Si. The valence and conduction band offset was found to be 0.12 eV and 0.35 eV, respectively, with a type-II band lineup. Deviation from theoretical prediction and previously published reports on quasi similar systems have been found and analyzed on the basis of the effect of strain, surface energy, shift in the electrostatic dipole and charge transfer at the interface. The carrier transport mechanisms along with different device parameters in the heterojunction have been studied for a temperature range of 180–300 K. This heterojunction is found to behave as an efficient infrared photodetector with an ON/OFF ratio of 21 at a reverse bias of 2 V. The corresponding rise and decay time was found to be 132 ms and 147 ms, respectively.

  15. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  16. Development of a portable and fast wire tension measurement system for MWPC construction

    Science.gov (United States)

    Pan, Jing-Hui; Ma, Chang-Li; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-09-01

    In a multi-wire proportional chamber detector (MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector’s stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure 3He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate, portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable. Supported by National Natural Science Foundation of China (A050506), State Key Laboratory of Particle Detection and Electronics and Key Laboratory of China Academy of Engineering Physics (Y490KF40HD)

  17. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  18. Método de fio quente na determinação das propriedades térmicas de polímeros Hot wire technique in the determination of thermal properties of polymers

    Directory of Open Access Journals (Sweden)

    Wilson N. dos Santos

    2004-12-01

    Full Text Available A técnica de fio quente paralelo normalizada para a determinação da condutividade térmica de materiais cerâmicos foi empregada na determinação das propriedades térmicas de polímeros. As amostras foram preparadas em forma de paralelepípedos retangulares, com dimensões de (230x80x30mm. Neste trabalho, a condutividade térmica e o calor específico foram simultaneamente determinados a partir do mesmo transiente térmico experimental e a difusividade térmica foi calculada a partir dessas duas propriedades. Cinco diferentes polímeros com diferentes estruturas a temperatura ambiente foram selecionados neste trabalho. Os cálculos foram feitos utilizando-se um método de ajuste por regressão não linear, de tal maneira que todos os pontos experimentais obtidos são considerados nos cálculos dessas propriedades térmicas. O equipamento utilizado neste trabalho é totalmente automatizado. A reprodutibilidade dos resultados foi muito boa com respeito à condutividade térmica, obtendo-se um desvio máximo de apenas 0,5% entre os valores máximo e mínimo para todas as amostras ensaiadas, mesmo introduzindo propositadamente alguns defeitos no arranjo experimental, em relação ao modelo teórico. Todavia, pequenos desvios do modelo teórico podem causar drásticas influências nos valores de calor específico, obtendo-se desvios de até 32% em relação ao arranjo experimental correto. Os resultados experimentais foram então comparados com aqueles encontrados na literatura. As discrepâncias observadas entre alguns desses valores podem estar associadas ao grau de cristalinidade ou à história térmica da amostra, ficando assim mostrada a aplicabilidade desta técnica na determinação das propriedades térmicas de polímeros.The hot wire parallel technique standardized for determining thermal conductivity of ceramic materials was employed in the determination of thermal properties of polymers. Samples were prepared in shape of rectangular

  19. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  20. Raman spectroscopy of WO{sub 3} nano-wires and thermo-chromism study of VO{sub 2} belts produced by ultrasonic spray and laser pyrolysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mwakikunga, B.W. [CSIR National Centre for Nano-Structured Materials, P.O. Box 395, Pretoria 0001 (South Africa); School of Physics, University of the Witwatersrand, Private Bag X3, P.O. Wits, Johanneburg 2050 (South Africa); Department of Physics and Biochemical Sciences, University of Malawi, The Polytechnic, Private Bag 303, Chichiri, Blantyre 3 (Malawi); Sideras-Haddad, E. [School of Physics, University of the Witwatersrand, Private Bag X3, P.O. Wits, Johanneburg 2050 (South Africa); Forbes, A. [CSIR National Laser Centre, P.O. Box 395, Pretoria 0001 (South Africa); School of Physics, University of Kwazulu-Natal, Private Bag X54001, Durban 4000 (South Africa); Arendse, C. [CSIR National Centre for Nano-Structured Materials, P.O. Box 395, Pretoria 0001 (South Africa)

    2008-01-15

    Novel optical and electrical properties of newly synthesized nano-wires of monoclinic WO{sub 3} and nano-belts of rutile VO{sub 2} have been investigated by Raman spectroscopy and thermo-chromism studies respectively. Phonon confinement is observed in the WO{sub 3} nano-wires and the previously modified Richter equation is fitted to the experimental Raman spectroscopy data to obtain the optical phonon dispersion relations for the 713 cm{sup -1} branch and the 808 cm{sup -1} branch of WO{sub 3} phonon spectra for the first time. Electrical measurements on the VO{sub 2} nano-belts at varying temperature reveal an enhanced hysteresis width of about 83 C surpassing previously reported values on the thermo-chromism studies on VO{sub 2}. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  1. Band gap tuning in As40Se53Sb07 thin films by 532 nm laser irradiation: An optical investigation by spectroscopic techniques

    Science.gov (United States)

    Pradhan, Prabhudutta; Naik, R.; Das, N.; Panda, A. K.

    2018-01-01

    The chalcogenide thin films belongs to a special category of important materials due to the unique IR transparency and light induced linear and non linear optical properties change. The optical band gap tuning in thermally evaporated As40Se53Sb07 chalcogenide thin film is being probed under the influence of 532 nm laser illumination. The gradual decrease in transmission and red shift of optical absorption edge with illumination at different time scale is recorded by Fourier transmission infrared spectroscopy. The simultaneous increase in refractive index and absorption coefficient of the illuminated film makes the material as useful candidate for optical switching. The dispersion of refractive index is being analyzed by using Wemple-DiDomenico (WDD) single oscillator model and static refractive index (n0) has also been reported. The exponential decrease of optical band gap with time is attributed to the increase in density of localized states and vacancies. The entire mechanism is explained by the microscopic model in which heteropolar bonds are converted to homopolar ones by the absorption of high energy photons investigated by X-ray photoelectron spectra. The amorphous nature of the studied films was revealed from X-ray diffraction and composition of the film was determined from energy dispersive X-ray analysis. The surface morphology was determined from the scanning electron microscopy. The optical change in absorption coefficient, refractive index, band gap by influence in laser irradiation in such materials may be suitable for optical disc(memory) application for optical time division switch.

  2. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Effect of electrical spot welding on load deflection rate of orthodontic wires.

    Science.gov (United States)

    Alavi, Shiva; Abrishami, Arezoo

    2015-01-01

    One of the methods used for joining metals together is welding, which can be carried out using different techniques such as electric spot welding. This study evaluated the effect of electric spot welding on the load deflection rate of stainless steel and chromium-cobalt orthodontic wires. In this experimental-laboratory study, load deflection rate of 0.016 × 0.022 inch stainless steel and chromium cobalt wires were evaluated in five groups (n =18): group one: Stainless steel wires, group two: chromium-cobalt wires, group three: stainless steel wires welded to stainless steel wires, group four: Stainless steel wires welded to chromium-cobalt wires, group five: chromium-cobalt wire welded to chromium-cobalt wires. Afterward, the forces induced by the samples in 0.5 mm, 1 mm, 1.5 mm deflection were measured using a universal testing machine. Then mean force measured for each group was compared with other groups. The data were analyzed using repeated measure analysis of variance (ANOVA), one-way ANOVA, and paired t-test by the SPSS software. The significance level was set as 0.05. The Tukey test showed that there were significant differences between the load deflection rates of welded groups compared to control ones (P wires increased their load deflection rates.

  4. Quantum wells, wires and dots theoretical and computational physics of semiconductor nanostructures

    CERN Document Server

    Harrison, Paul

    2016-01-01

    Quantum Wells, Wires and Dots provides all the essential information, both theoretical and computational, to develop an understanding of the electronic, optical and transport properties of these semiconductor nanostructures. The book will lead the reader through comprehensive explanations and mathematical derivations to the point where they can design semiconductor nanostructures with the required electronic and optical properties for exploitation in these technologies. This fully revised and updated 4th edition features new sections that incorporate modern techniques and extensive new material including: - Properties of non-parabolic energy bands - Matrix solutions of the Poisson and Schrodinger equations - Critical thickness of strained materials - Carrier scattering by interface roughness, alloy disorder and impurities - Density matrix transport modelling -Thermal modelling Written by well-known authors in the field of semiconductor nanostructures and quantum optoelectronics, this user-friendly guide is pr...

  5. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    , therefore, we’ve drawn conclusions and recommendations for future editions of the event, also generalizable to other experiences of gamification especially in events. This report details the methodology and working elements from the design phase, human resources and organization of production......This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...... proposed new ones (viralization of the event on social networks and improvement of the integration of international attendees). On the other hand we defined a set of research objectives related to the study of gamification in an eminently social place like an event. Most of the goals have been met and...

  6. Synthesise of Zn O nano wires by direct oxidation method

    International Nuclear Information System (INIS)

    Farbod, M.; Ahangarpour, A.

    2007-01-01

    Zn O is a semiconductor which has a direct and wide energy band which is about 3.37 eV at room temperature. It has various applications from UV lasers, sensitive sensors, solar cells to photo catalysis applications. Zn O has different nano structures such as nanoparticles, nano wires, nano rods, nano tubes and nano belts. The one dimensional Zn O nano structures such as nano wires are very important because of their applications in nano electronics and nano photonics so different methods have been proposed to synthesize them. In this work large scale of Zn O nano wires are produced by direct oxidation a Zn substrate (which was cleaned by chemical methods) in air or oxygen atmosphere at 400 d eg C . Nano wires were investigated by scanning electron microscopy and energy dispersive x-ray measurements. Their diameter is about 30-150 nanometer and their length is about several micrometer. This method which acts without any catalyst is a convenient method to synthesis semiconductor nano wires.

  7. Nano-/micro metallic wire synthesis on Si substrate and their characterization

    International Nuclear Information System (INIS)

    Kaur, Jaskiran; Kaur, Harmanmeet; Singh, Surinder; Kanjilal, Dinakar; Chakarvarti, Shiv Kumar

    2014-01-01

    Nano-/micro wires of copper are grown on semiconducting Si substrate using the template method. It involves the irradiation of 8 um thick polymeric layer coated on Si with150 MeV Ni ion beam at a fluence of 2E8. Later, by using the simple technique of electrodeposition, copper nano-/micro wires were grown via template synthesis. Synthesized wires were morphologically characterized using SEM and electrical characterization was carried out by finding I-V plot

  8. Wire Array Solar Cells: Fabrication and Photoelectrochemical Studies

    Science.gov (United States)

    Spurgeon, Joshua Michael

    Despite demand for clean energy to reduce our addiction to fossil fuels, the price of these technologies relative to oil and coal has prevented their widespread implementation. Solar energy has enormous potential as a carbon-free resource but is several times the cost of coal-produced electricity, largely because photovoltaics of practical efficiency require high-quality, pure semiconductor materials. To produce current in a planar junction solar cell, an electron or hole generated deep within the material must travel all the way to the junction without recombining. Radial junction, wire array solar cells, however, have the potential to decouple the directions of light absorption and charge-carrier collection so that a semiconductor with a minority-carrier diffusion length shorter than its absorption depth (i.e., a lower quality, potentially cheaper material) can effectively produce current. The axial dimension of the wires is long enough for sufficient optical absorption while the charge-carriers are collected along the shorter radial dimension in a massively parallel array. This thesis explores the wire array solar cell design by developing potentially low-cost fabrication methods and investigating the energy-conversion properties of the arrays in photoelectrochemical cells. The concept was initially investigated with Cd(Se, Te) rod arrays; however, Si was the primary focus of wire array research because its semiconductor properties make low-quality Si an ideal candidate for improvement in a radial geometry. Fabrication routes for Si wire arrays were explored, including the vapor-liquid-solid growth of wires using SiCl4. Uniform, vertically aligned Si wires were demonstrated in a process that permits control of the wire radius, length, and spacing. A technique was developed to transfer these wire arrays into a low-cost, flexible polymer film, and grow multiple subsequent arrays using a single Si(111) substrate. Photoelectrochemical measurements on Si wire array

  9. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  10. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft fractures in children: A treatment concept.

    Science.gov (United States)

    Sahu, Ramji Lal

    2013-09-01

    Fractures of the humeral shaft are uncommon, representing less than 10 percent of all fractures in children. Humeral shaft fractures in children can be treated by immobilisation alone. A small number of fractures are unable to be reduced adequately or maintained in adequate alignment, and these should be treated surgically. In the present study, Kirschner wires (K-wire) were used to achieve a closed intramedullary fixation of humeral shaft fractures. The objective of this study was to evaluate the efficacy of intramedullary K-wires for the treatment of humeral shaft fracture in children. This prospective study was conducted in the Department of Orthopaedic surgery in M. M. Medical College from June 2005 to June 2010. Sixty-eight children with a mean age of 7.7 years (range, 2-14 years) were recruited from Emergency and out patient department having closed fracture of humerus shaft. All patients were operated under general anaesthesia. All patients were followed for 12 months. Out of 68 patients, 64 patients underwent union in 42-70 days with a mean of 56 days. Complications found in four patients who had insignificant delayed union which were united next 3 weeks. Intramedullary K-wires were removed after an average of 5 months without any complications. The results were excellent in 94.11% and good in 5% children. This technique is simple, quick to perform, safe and reliable and avoids prolonged hospitalization with good results and is economical.

  11. Size-dependent and intra-band photoluminescence of NiS{sub 2} nano-alloys synthesized by microwave assisted hydrothermal technique

    Energy Technology Data Exchange (ETDEWEB)

    Linganiso, Ella Cebisa [DST/CSIR National Centre for Nano-Structured Materials, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001 (South Africa); Molecular Sciences Institute, School of Chemistry, University of the Witwatersrand, Private Bag 3, Johannesburg, Wits 2050 (South Africa); Mhlanga, Sabelo Dalton; Coville, Neil John [Molecular Sciences Institute, School of Chemistry, University of the Witwatersrand, Private Bag 3, Johannesburg, Wits 2050 (South Africa); DST/NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, Private Bag 3, Johannesburg, Wits 2050 (South Africa); Mwakikunga, Bonex Wakufwa, E-mail: bmwakikunga@csir.co.za [DST/CSIR National Centre for Nano-Structured Materials, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001 (South Africa); Department of Physics and Biochemical Sciences, University of Malawi, The Polytechnic, Private Bag 303, Chichiri, Blantyre 3 (Malawi)

    2013-03-05

    Graphical abstract: Unexpected ultra-violet (UV) emission as well as near infra-red (IR) emissions were attributed to intra-band energy state transitions that occur as a result of the porous structure of the material. Enhanced UV and near IR PL emissions due to the smaller crystallite size of the capped NiS{sub 2} nanostructures was also observed. Band energy and local density of states calculation for NiS{sub 2} were used to support the experimentally observed luminescence results. The luminescence features at wavelengths of 400 nm (3.10 eV), 428 nm (2.90 eV), 447 nm (2.77 eV) and 464 nm (2.67) can be attributed to some of those electrons de-exciting from S (3p) levels down to the Ni (3d) (blue to UV emission) whereas those features at wavelengths of 710 nm (1.75 eV), 751 nm (1.65 eV), 754 nm (1.64 eV) [NiS{sub 2}/HDA-capped NiS{sub 2}] and 784 nm (1.58 eV) respectively seem to result from de-excitations between either Ni(3d) or S (3s, 3p) levels and Ni–S hybridization levels (red to near IR emission). Highlights: ► Rapid solid state alloying of Ni and S from their liquid state precursor by microwaves. ► New photoluminescence data of NiS{sub 2} system. ► Unexpected luminescence in the UV–Visible and near IR ranges for such a metal matrix alloy. ► Explanation of NiS{sub 2} photoluminescence from ab initio calculations by electronic energy band structure and density of states. -- Abstract: Synthesis of nickel disulfide (NiS{sub 2}) nano-alloys capped and uncapped with hexadecylamine (HDA) was carried out. A cubic phase NiS{sub 2} formation was confirmed by X-ray diffraction (XRD) analysis. An average crystallite size of 35 nm was obtained for the uncapped nanostructures and 9 nm was obtained for the capped nanostructures estimated using the Scherrer equation. Unexpected ultra-violet (UV) emission as well as near infrared (IR) emissions were attributed to intra-band energy state transitions that occur as a result of the porous structure of the material

  12. A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures.

    Science.gov (United States)

    Wang, Wulian; Wu, Guangwen; Shen, Fuer; Zhang, Yiyuan; Liu, Xianxiang

    2012-12-01

    The aim of the present study was to evaluate the stability of the figure of eight plus circular wiring fixation technique compared with four common internal fixation techniques and to provide experimental data for the selection of internal fixation techniques clinically. A total of 20 fresh cadaveric elbow joints were used as transverse, oblique and comminuted olecranon fracture models. Five techniques of internal fixation were investigated: circular wiring, figure of eight wiring, circular plus figure of eight wiring, Kirschner wire (K-wire) and screw fixation. The elbow joints were flexed at 90°. The fixation performance was tested using a high-precision displacement sensor. Displacement-load curves revealed that the strength of internal fixation was weakest when using circular wiring alone and that circular wiring plus figure of eight wiring fixation was stronger than that of figure of eight wiring or screw fixation. The difference was statistically significant (Pwiring plus figure of eight wiring fixation and K-wire fixation in the transverse and oblique fracture models (P>0.05). However, figure of eight plus circular wiring fixation was superior to K-wire fixation in the comminuted fracture model, with a tensile force of 67.42±2.17 vs. 58.52±2.17 N, respectively (Pwiring plus figure of eight wiring fixation recovered and 108 were included in the follow-up for an average of 12 months. The rate of excellent/fairly good recovery was 98.10%. Due to its reliability, simple surgery, lower invasiveness and lower cost, figure of eight plus circular wiring fixation is an ideal choice for the internal fixation of olecranon fractures, particularly comminuted fractures, compared with circular wiring, figure of eight wiring or screw fixation.

  13. A comparative chromosome analysis of Thai wild boar (Sus scrofa jubatus and relationship to domestic pig (S. s. domestica by conventional staining, G-banding and high-resolution technique

    Directory of Open Access Journals (Sweden)

    Pornnarong Siripiyasing

    2007-01-01

    Full Text Available This research is the first comparative chromosome analysis report of Thai wild boar (Sus scrofa jubatus and its relationship to domestic pig (S. s. domestica by conventional staining, G-banding and high-resolution technique. Blood samples of the Thai wild boar were taken from two males and two females kept in Nakhon Ratchasima Zoo. After standard whole blood lymphocyte culture at 37 oC for 72 hr. in the presence of colchicine, the metaphase spreads were performed on microscopic slides and airdried. Conventional staining, G-banding and high-resolution technique were applied to stain the chromosomes. The results showed that the number of diploid chromosomes of Thai wild boar was 2n (diploid = 38, and the fundamental numbers (NF were 62 in the male and female. The type of autosomes were 12 metacentric, 14 submetacentric, 4 acrocentric and 6 telocentric chromosomes, with X and Y chromosomes being metacentric chromosomes. We found that chromosomes 1, 5, 7, 8, 10, 11, 12, 13, 14, 16, 17, 18, X and Y had the same Gbanding and high-resolution technique patterns as those of domestic pig chromosomes. Chromosomes 2, 3, 4, 6, 9 and 15 are similar to those of domestic pig chromosomes. These results show the evolutionary relationship between the Thai wild boar and the domestic pig.

  14. Dendritic and Axonal Wiring Optimization of Cortical GABAergic Interneurons.

    Science.gov (United States)

    Anton-Sanchez, Laura; Bielza, Concha; Benavides-Piccione, Ruth; DeFelipe, Javier; Larrañaga, Pedro

    2016-10-01

    The way in which a neuronal tree expands plays an important role in its functional and computational characteristics. We aimed to study the existence of an optimal neuronal design for different types of cortical GABAergic neurons. To do this, we hypothesized that both the axonal and dendritic trees of individual neurons optimize brain connectivity in terms of wiring length. We took the branching points of real three-dimensional neuronal reconstructions of the axonal and dendritic trees of different types of cortical interneurons and searched for the minimal wiring arborization structure that respects the branching points. We compared the minimal wiring arborization with real axonal and dendritic trees. We tested this optimization problem using a new approach based on graph theory and evolutionary computation techniques. We concluded that neuronal wiring is near-optimal in most of the tested neurons, although the wiring length of dendritic trees is generally nearer to the optimum. Therefore, wiring economy is related to the way in which neuronal arborizations grow irrespective of the marked differences in the morphology of the examined interneurons.

  15. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems. Electrical wiring shall be installed and maintained to conform to SAE J1292—Automobile, Truck, Truck-Tractor...

  16. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  18. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  19. The Use of C-/X-Band Time-Gapped SAR Data and Geotechnical Models for the Study of Shanghai’s Ocean-Reclaimed Lands through the SBAS-DInSAR Technique

    Directory of Open Access Journals (Sweden)

    Antonio Pepe

    2016-11-01

    Full Text Available In this work, we investigate the temporal evolution of ground deformation affecting the ocean-reclaimed lands of the Shanghai (China megacity, from 2007 to 2016, by applying the Differential Synthetic Aperture Radar Interferometry (DInSAR technique known as the Small BAseline Subset (SBAS algorithm. For the analysis, we exploited two sets of non-time-overlapped synthetic aperture radar (SAR data, acquired from 2007 to 2010, by the ASAR/ENVISAT (C-band instrument, and from 2014 to 2016 by the X-band COSMO-SkyMed (CSK sensors. The long time gap (of about three years existing between the available C- and X-band datasets made the generation of unique displacement time-series more difficult. Nonetheless, this problem was successfully solved by benefiting from knowledge of time-dependent geotechnical models, which describe the temporal evolution of the expected deformation affecting Shanghai’s ocean-reclaimed platforms. The combined ENVISAT/CSK (vertical deformation time-series were analyzed to gain insight into the future evolution of displacement signals within the investigated area. As an outcome, we find that ocean-reclaimed lands in Shanghai experienced, between 2007 and 2016, average cumulative (vertical displacements extending down to 25 centimeters.

  20. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  1. Circummandibular wiring made easy: A case report

    Directory of Open Access Journals (Sweden)

    Jasmeet Singh

    2014-10-01

    Full Text Available Mandibular fractures are less common in children as compared to adults. The treatment plan in children has to be modified as compared to adults considering the presence of tooth buds and potential disturbances in growth. Use of acrylic splints has been one of the popular techniques in children because of its relatively easy placement and reduced risk of hindrances to growth of jaw. These splints have been traditionally been fixed with the help of cements and circummandibular wires. We describe the use of intravenous cannula stilete instead of traditional bone awl to secure the splint in place.

  2. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  3. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  4. Designing aligned inorganic nanotubes at the electrode interface: towards highly efficient photovoltaic wires

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Tao; Qiu, Longbin; Yang, Zhibin; Peng, Huisheng [State Key Laboratory of Molecular, Engineering of Polymers, Department of Macromolecular Science and Laboratory of Advanced Materials, Fudan University, Shanghai (China); Kia, Hamid G. [Chemical Sciences and Materials Systems Lab, GM Global R and D, Warren, MI (United States)

    2012-09-04

    Aligned carbon and titanium dioxide nanotubes are designed at the electrode interface to improve the charge separation and transport. The resulting organic photovoltaic wire exhibits high power conversion efficiency. This flexible photovoltaic wire can be easily integrated into a textile by a conventional weaving technique. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Excess noise in the steel suspension wires for the laser gravitational wave detector

    Science.gov (United States)

    Ageev, A. Yu.; Bilenko, I. A.; Braginsky, V. B.

    1998-09-01

    Progress in the research in mechanical excess noise is reported. An improved technique for wire oscillation measurement has been applied to the investigation of the suspension of a test mass for a GW detector. The dependence of the excess noise intensity in the fundamental violin mode of the steel wires on the stress value is obtained.

  6. Comparative assessment between eyelet wiring and direct interdental wiring for achieving intermaxillary fixation: a prospective randomized clinical study.

    Science.gov (United States)

    Rai, Anshul; Datarkar, Abhay; Borle, Rajeev; Rai, Monika

    2012-08-01

    The intention of this study was to compare the efficacy of eyelet wiring and direct interdental (Gilmer) wiring for achieving intermaxillary fixation (IMF). This study was a prospective randomized clinical trial. The study sample was derived from the population of patients who underwent IMF at the Department of Oral and Maxillofacial Surgery, Sharad Pawar Dental College, Wardha, India, between October 2008 and September 2010. The time required for placement and removal (in minutes) was compared between the eyelet wiring and direct interdental wiring techniques. Postoperative stability after achieving IMF was analyzed in the 2 groups. The plaque accumulation in both groups was evaluated using the Turesky-Gilmore-Glickman modification of the Quigley-Hein plaque index. Complications in the form of soft tissue injury, glove puncture, and trauma to the operator's finger were also recorded. Statistical analysis was performed with SPSS statistical software for Windows, version 8.0 (SPSS, Chicago, IL) using the χ(2) test and Student t test. The mean working time for placement and removal of eyelet wiring (group I) was 18.00 minutes and 9.67 minutes, respectively. For direct interdental wiring (group II), it was 30.50 minutes and 23.12 minutes, respectively. The mean plaque index values were 1.78 and 2.54 for groups I and II, respectively, which signifies a higher plaque deposition in group II. No occlusal disturbance was seen in either group. The incidences of glove perforation, soft tissue trauma, and trauma to the operator's finger were higher in group II. Eyelet wiring is preferable to direct interdental wiring as evidenced by fewer complications, and requires a shorter operating time in patients with minimally displaced fractures. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Loss of Guide Wire: A Rare Complication of Intra-Aortic Balloon Pump Insertion

    Directory of Open Access Journals (Sweden)

    Manouchehr Hekmat

    2015-10-01

    Full Text Available At the final stages of a coronary artery bypass graft operation on a 64-year-old man, an experienced physician attempted to insert an intra-aortic balloon pump into the femoral artery via the Seldinger technique. However, while the balloon pump was being passed over the guide wire, the latter was completely lost.The guide wire should be held at the tip at all times to prevent passage into the vessel. Strict adherence to this rule will prevent guide-wire loss, which is, albeit rare and completely avoidable, a potentially life-threatening complication of central vein or artery catheterization, with reported fatality rates of up to 20% when the whole wire is lost. The literature contains several reports on guide-wire loss during central venous, arterial, and hemodialysis catheterization, but we report for the first time the loss of a guide wire as a rare complication of intra-aortic balloon pump insertion.

  8. Present status of PIT round wires of 122-type iron-based superconductors

    Science.gov (United States)

    Tamegai, T.; Suwa, T.; Pyon, S.; Kajitani, H.; Takano, K.; Koizumi, N.; Awaji, S.; Watanabe, K.

    2017-12-01

    Outstanding characteristics with high T c and H c2 and small anisotropy in iron-based superconductors (IBSs) have triggered the development of superconducting wires and tapes using these novel superconductors. In this short article, developments and present status of round wires of 122-type IBSs are reviewed. By introducing hot-isostatic pressing (HIP) technique, J c in round wires of 122-type IBSs has been improved significantly. Further improvements have been realized by refining the fabrication process of the core material and introducing partial texturing of the wire core. The largest transport J c for round wires at 4.2 K at self-field and 100 kOe are 2.0x105 A/cm2 and 3.8x104 A/cm2, respectively. We also compare the J c characteristics of wires and tapes processed by HIP.

  9. Band-notched ultrawide band antenna loaded with ferrite slab

    Science.gov (United States)

    Wang, Hao; Zong, Weihua; Sun, Nian X.; Lin, Hwaider; Li, Shandong

    2017-05-01

    In this paper, a novel technique to design a band-notched UWB antenna by using Yttrium Iron Garnet (YIG) ferrite is proposed. A printed slot UWB antenna with size of 21mm×26 mm×0.8 mm is adopted as a basic antenna. A piece of ferrite slab with size of 5 mm×10 mm×2 mm is attached on the feeding layer of the antenna to achieve band-notched characteristics. The measured -10 dB bandwidth of the antenna without ferrite slab is 2.91-10.98 GHz. With loading of ferrite slab, the bandwidth turns to 2.73-5.12 and 5.87-10.78 GHz. A band notch of 5.12- 5.87 GHz is achieved to filter WLAN 5 GHz (5.15-5.825 GHz) band. The proposed technique has virtue of easy fabrication and keeping antenna miniaturization.

  10. Topological phases and transport properties of screened interacting quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Hengyi, E-mail: hengyi.xu@njnu.edu.cn [School of Physics and Technology, Nanjing Normal University, Nanjing 210023 (China); Xiong, Ye [School of Physics and Technology, Nanjing Normal University, Nanjing 210023 (China); Wang, Jun [Department of Physics, Southeast University, Nanjing 210096 (China)

    2016-10-14

    We study theoretically the effects of long-range and on-site Coulomb interactions on the topological phases and transport properties of spin–orbit-coupled quasi-one-dimensional quantum wires imposed on a s-wave superconductor. The distributions of the electrostatic potential and charge density are calculated self-consistently within the Hartree approximation. Due to the finite width of the wires and charge repulsion, the potential and density distribute inhomogeneously in the transverse direction and tend to accumulate along the lateral edges where the hard-wall confinement is assumed. This result has profound effects on the topological phases and the differential conductance of the interacting quantum wires and their hybrid junctions with superconductors. Coulomb interactions renormalize the gate voltage and alter the topological phases strongly by enhancing the topological regimes and producing jagged boundaries. Moreover, the multicritical points connecting different topological phases are modified remarkably in striking contrast to the predictions of the two-band model. We further suggest the possible non-magnetic topological phase transitions manipulated externally with the aid of long-range interactions. Finally, the transport properties of normal–superconductor junctions are further examined, in particular, the impacts of Coulomb interactions on the zero-bias peaks related to the Majorana fermions and near zero-energy peaks. - Highlights: • A model of the screened Coulomb interactions in Majorana wires is proposed. • The interacting topological phase diagrams in multiband quantum wires are revealed. • The Majorana fermions in interacting multiband quantum wires are investigated.

  11. Métodos transientes de troca de calor na determinação das propriedades térmicas de materiais cerâmicos: II - o método do fio quente Thermal properties of ceramic materials by the non-steady techniques: II - the hot wire technique

    Directory of Open Access Journals (Sweden)

    W. N. dos Santos

    2005-12-01

    diffusivity is important in non-steady heat transfer calculations. The specific heat is also a decisive property of ceramic materials in high temperature applications, and it is associated with heat consumption during the heating process. Normally these properties are determined separately by individual techniques and apparatus. Nowadays, several different techniques for the determination of the thermal diffusivity and thermal conductivity may be found in the literature. Recently, transient techniques have become the preferable way for measuring thermal properties of materials. In this work it is presented a description as well as a critical analysis of one experimental technique employed worldwide for thermal properties measurements of ceramic materials: the hot wire technique. With this technique it is possible to determine simultaneously from the same temperature transient the three thermal properties. Numerical results are also presented.

  12. A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures

    OpenAIRE

    WANG, WULIAN; WU, GUANGWEN; SHEN, FUER; ZHANG, YIYUAN; LIU, XIANXIANG

    2012-01-01

    The aim of the present study was to evaluate the stability of the figure of eight plus circular wiring fixation technique compared with four common internal fixation techniques and to provide experimental data for the selection of internal fixation techniques clinically. A total of 20 fresh cadaveric elbow joints were used as transverse, oblique and comminuted olecranon fracture models. Five techniques of internal fixation were investigated: circular wiring, figure of eight wiring, circular p...

  13. High resolution STEM of quantum dots and quantum wires

    DEFF Research Database (Denmark)

    Kadkhodazadeh, Shima

    2013-01-01

    This article reviews the application of high resolution scanning transmission electron microscopy (STEM) to semiconductor quantum dots (QDs) and quantum wires (QWRs). Different imaging and analytical techniques in STEM are introduced and key examples of their application to QDs and QWRs...

  14. Negative differential resistance in a one-dimensional molecular wire ...

    Indian Academy of Sciences (India)

    from semi-empirical to density functional theory (DFT) based methods [8–14] have been explored to describe .... Figure 2 shows the equilibrium density of states and transmission for this half- filled wire, with λ = 1 .... semiconductors and organic nano-techniques edited by H Morkoc (Academic Press,. 2003). [2] M A Reed, C ...

  15. Analysis of pulsed wire method for field integral measurements in ...

    Indian Academy of Sciences (India)

    In this paper, we present a theoretical analysis of this technique by finding out the analytic solution of the differential equation for the forced vibration of the wire taking dispersion due to stiffness into account. Method of images is used to extend these solutions to include reflections at the ends. For long undulators, the effect of ...

  16. Hot-wire assisted atomic layer deposition of Tungsten films

    NARCIS (Netherlands)

    Yang, Mengdi

    2018-01-01

    This thesis aims to establish a novel technique of atomic layer deposition (ALD) for the future ultra-large-scale integration (ULSI) of microelectronics. We developed a hot-wire assisted ALD (HWALD), where a heated tungsten (W) filament is utilized instead of a plasma to generate radicals. HWALD is

  17. New analysis of the ν5 and 2 ν9 bands of HNO 3 by infrared and millimeter wave techniques: line positions and intensities

    Science.gov (United States)

    Perrin, A.; Orphal, J.; Flaud, J.-M.; Klee, S.; Mellau, G.; Mäder, H.; Walbrodt, D.; Winnewisser, M.

    2004-12-01

    Nitric acid (HNO 3) plays an important role in the Earth's atmosphere as a reservoir molecule of NO x species. It has a strong infrared signature at 11 μm which is one of the most commonly used for the infrared retrieval of this species in the atmosphere since this spectral region coincides with an atmospheric window. It is therefore essential to have high quality spectral parameters in this spectral region. The main goal of this work is then to generate as reliable as possible line positions and intensities for the ν5 and 2 ν9 cold bands centered at 879.1075 and 896.4467 cm -1, respectively. In particular the existing line parameters need improvement in the wings of the 11 μm window in order to retrieve more accurately the CFC-11 (CCl 3F) and CFC-12 (CCl 2F 2) atmospheric species at ˜850 and ˜920 cm -1, respectively. This work is also motivated by theoretical considerations. Very strong resonances couple indeed the 5 1 and 9 2 rotational levels. In addition the ν9 mode (OH torsion) is a "large amplitude" motion, and torsional splittings affect both the v9=2 and the v5=1 rotational transitions. In the present study, these effects are accounted for simultaneously both for the line position and line intensity calculations. To calculate the line positions the Hamiltonian matrix accounts for the very strong Fermi and the weaker Coriolis interactions linking the 5 1⇔9 2 rotational levels, and the torsional effects are accounted for within the frame of the IAM (Internal Axis Method) approach. In addition, the v-diagonal blocks involve non-orthorhombic operators together with Watson's type rotational operators. This means that the z-quantization axis deviates from the a inertial axis for both the 5 1 and 9 2 vibrational states. The line intensity calculations were performed accounting also for the axis switching effects. As far as the experimental line positions are concerned we have used the millimeter wave data available in the literature [J. Mol. Spectrosc

  18. Ferroelectric and photocatalytic behavior of bismuth ferrite nano wire

    Science.gov (United States)

    William, R. V.; Marikani, A.; Madhavan, D.

    2016-05-01

    Multiferroic bismuth ferrite nanowires are prepared through polyol method with an average diameter of 35 nm with a narrow size distribution. The band gap was determined to be 2.10 eV, indicating their potential application as visible-light-response photo catalyst. The magnificent photocatalytic behaviors of BiFeO3 nanowires are understood from the methyl violet degradation under visible light irradiation. Moreover, the nano-wire takes only a lesser time for the diffusion of electron-hole pair from the surface of the sample. Further the BiFeO3 nano-wire was characterized using XRD, SEM, and U-V. The ferroelectric studies of BiFeO3 nano-wire show a frequency dependent property and maximum coercivity of 2.7 V/cm were achieved with a remanent polarization at 0.5 µC/cm2 at the frequency 4 kHz. The coercivity of BiFeO3 nano wire changes with variation of frequency from 1 kHz to 4 kHz.

  19. Ferroelectric and photocatalytic behavior of bismuth ferrite nano wire

    Energy Technology Data Exchange (ETDEWEB)

    William, R. V.; Marikani, A., E-mail: amari@mepcoeng.ac.in [Department of Physics, Mepco Schlenk Engineering College, Sivakasi – 626 005, Tamil Nadu (India); Madhavan, D. [Department of Chemistry, Mepco Schlenk Engineering College, Sivakasi – 626 005, Tamil Nadu (India)

    2016-05-23

    Multiferroic bismuth ferrite nanowires are prepared through polyol method with an average diameter of 35 nm with a narrow size distribution. The band gap was determined to be 2.10 eV, indicating their potential application as visible-light-response photo catalyst. The magnificent photocatalytic behaviors of BiFeO{sub 3} nanowires are understood from the methyl violet degradation under visible light irradiation. Moreover, the nano-wire takes only a lesser time for the diffusion of electron-hole pair from the surface of the sample. Further the BiFeO{sub 3} nano-wire was characterized using XRD, SEM, and U-V. The ferroelectric studies of BiFeO{sub 3} nano-wire show a frequency dependent property and maximum coercivity of 2.7 V/cm were achieved with a remanent polarization at 0.5 µC/cm{sup 2} at the frequency 4 kHz. The coercivity of BiFeO{sub 3} nano wire changes with variation of frequency from 1 kHz to 4 kHz.

  20. Severe deformation twinning in pure copper by cryogenic wire drawing

    International Nuclear Information System (INIS)

    Kauffmann, A.; Freudenberger, J.; Geissler, D.; Yin, S.; Schillinger, W.; Sarma, V. Subramanya; Bahmanpour, H.; Scattergood, R.; Khoshkhoo, M.S.; Wendrock, H.; Koch, C.C.; Eckert, J.; Schultz, L.

    2011-01-01

    The effect of low-temperature on the active deformation mechanism is studied in pure copper. For this purpose, cryogenic wire drawing at liquid nitrogen temperature (77 K) was performed using molybdenum disulfide lubrication. Microstructural investigation and texture analysis revealed severe twin formation in the cryogenically drawn copper, with a broad twin size distribution. The spacing of the observed deformation twins ranges from below 100 nm, as reported in previous investigations, up to several micrometers. The extent of twin formation, which is significantly higher when compared to other cryo-deformation techniques, is discussed with respect to the state of stress and the texture evolution during wire drawing.

  1. Twin - Arch technique. Revival of the "edgewise -Technique"?

    Directory of Open Access Journals (Sweden)

    Jacob Karp

    2012-01-01

    The SNB – Bracket brings a new dimension into the orthodontic world which is most apparent in extraction cases. Its Teflon – like material has a very low friction coefficient thus, reducing the treatment time considerably. Through the use of low dimensioned arch wires, the Twin – Arch Technique becomes a Light – wire system and simultaneously provides good anchorage and torque control.

  2. In-situ transmission electron microscopy observation of electromigration in Au thin wires.

    Science.gov (United States)

    Murakami, Yosuke; Arita, Masashi; Hamada, Kouichi; Takahashi, Yasuo

    2012-11-01

    Electromigration of thin Au wire is studied by the use of in-situ transmission electron microscopy (TEM) techniques from the viewpoint of nanogap formation. We use a relatively wide Au wire as a starting material because the position-dependent structure change in the wire provides information of the thermal effect caused by the current flow. In-situ TEM observation, in which current measurements of the Au wire are simultaneously performed, reveals the process of the growth of voids and grains. Finally the formation of a nanogap by electromigration is observed doing with current measurements. All the results observed by in-situ TEM indicate the fact that the thermal effects or temperature increase in the wire region take an important role for the structure change caused by electromigration of Au in the wire. It is suggested that the position of the nanogap can roughly be arranged by setting the wire structure and current direction even though a relatively wide wire was used. The detailed observation by in-situ TEM also suggests that the control of heat generation in the wire makes the nanogap sharp because of the well-controlled recrystallization of Au nanowires.

  3. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Ekelund, M; Gedde, U.W. (Royal Institute of Technology (KTH). Fibre and Polymer Technology, School of Chemical Science and Engineering, Stockholm (Sweden)); Fantoni, P.F. (Institute for Energy Technology (IFE), Halden (Norway))

    2011-05-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  4. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Ekelund, M; Gedde, U.W.; Fantoni, P.F.

    2011-05-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  5. A projector of iridium 192 wires: motivations and preliminary studies

    International Nuclear Information System (INIS)

    Cosset, J.M.; Gerbaulet, A.; Chassagne, D.

    1979-01-01

    Though the majority of procedures involved in curietherapy with Iridium 192 wires cause very few problems concerning radiation protection, this is not true in all cases: in elderly of debilitated patients, young children, or when using special techniques (curietherapy for prostate of bladder cancers for example). In these cases, the need for frequent treatment exposes the therapists to increased doses. The projector of Iridium 192 wires was conceived in order to reduce this irradiated hazard. A simple manipulation places the radioactive wires in a lead container during treatment, and then replaces them in the right position after therapy. This apparatus appears to offer the possibility of: an almost total protection of the therapists, and thus an opportunity for enlarging the indications for curietherapy; an improved quality of treatment to the patient during the application [fr

  6. CCD Photometry of bright stars using objective wire mesh

    Energy Technology Data Exchange (ETDEWEB)

    Kamiński, Krzysztof; Zgórz, Marika [Astronomical Observatory Institute, Faculty of Physics, A. Mickiewicz University, Słoneczna 36, 60-286 Poznań (Poland); Schwarzenberg-Czerny, Aleksander, E-mail: chrisk@amu.edu.pl [Copernicus Astronomical Centre, ul. Bartycka 18, PL 00-716 Warsaw (Poland)

    2014-06-01

    Obtaining accurate photometry of bright stars from the ground remains problematic due to the danger of overexposing the target and/or the lack of suitable nearby comparison stars. The century-old method of using objective wire mesh to produce multiple stellar images seems promising for the precise CCD photometry of such stars. Furthermore, our tests on β Cep and its comparison star, differing by 5 mag, are very encouraging. Using a CCD camera and a 20 cm telescope with the objective covered by a plastic wire mesh, in poor weather conditions, we obtained differential photometry with a precision of 4.5 mmag per two minute exposure. Our technique is flexible and may be tuned to cover a range as big as 6-8 mag. We discuss the possibility of installing a wire mesh directly in the filter wheel.

  7. Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study.

    Science.gov (United States)

    Apivatthakakul, T; Phaliphot, J; Leuvitoonvechkit, S

    2013-02-01

    A percutaneous cerclage wiring technique has been developed to reduce iatrogenic soft tissue and vascular disruption associated with classic cerclage fixation. The purpose of this study was to evaluate the extent of femoral vascular disruption resulting iatrogenically from the application of two percutaneous cerclage wire loops. Pairs of cerlage wire loops were percutaneously inserted on 18 fresh cadaveric femurs. The position of the wire loops varied. The wire loops were either inserted 10 and 15cm, 10 and 20cm, or 15 and 20cm distal to the tip of the greater trochanter. Each study group had 6 cadavers. Contralateral femurs without cerclage wiring were used as controls. Liquid contrast-gelatin was injected into the common femoral artery. Using axial and 3D CT scan images the superficial femoral artery (SFA), deep femoral artery (DFA), perforating arteries and their anastomotic patterns as well as endosteal perfusion were identified and their patency was graded. Percutaneous cerclage wiring did not disrupt femoral endosteal blood supply and maintained the integrity of all of the superficial femoral arteries. Four specimens demonstrated maintenance of all 4 perforators, 11 showed disruption of 1 perforator, and 3 showed disruption of 2 perforators. One deep femoral artery was disrupted after its first perforator branched off; however, perfusion was maintained by fill from an alternative anastamosis. There was no significant difference between disruption of deep femoral arteries and perforating arteries (P=1.000), location of wiring (P=0.905) or spacing between wire loops (P=1.000). Percutaneous cerclage wiring resulted in minimal disruption of the femoral blood supply. When partial disruption occurred the SFA, DFA, and their associated perforators compensated to maintain femoral perfusion through their anastomoses. The location of the cerclage wire and the distance between the wire loops in the proximal femur showed no significant difference in the rate of

  8. Dermabrasion by wire brush.

    Science.gov (United States)

    Yarborough, J M

    1987-06-01

    While many physicians choose the fraise for all dermabrasive surgery, others prefer the faster abrasiveness and reduced friction of the brush for deep full-faced abrasions, removal of tattoos, and revision of scars. In addition to preoperative preparation and postoperative care of the patient, the author's technique for full-face abrasion with the power-driven rotary brush is described.

  9. Wired or Wireless Internet?

    DEFF Research Database (Denmark)

    Gimpel, Gregory

    2010-01-01

    This paper finds that network externalities play a minimal role in the choice of internet access technology. Potential adopters of mobile laptop internet view broadband technology as a black box, the technological details of which donot matter. The study uses qualitative techniques to explore how...

  10. Understanding the mechanism of nanoparticle formation in wire explosion process

    International Nuclear Information System (INIS)

    Bora, B.; Wong, C.S.; Bhuyan, H.; Lee, Y.S.; Yap, S.L.; Favre, M.

    2013-01-01

    The mechanism of nanoparticle formation by wire explosion process has been investigated by optical emission spectroscopy in Antony et al. 2010 [2] [J Quant Spectrosc Radiat Transfer 2010; 111:2509]. It was reported that the size of the nanoparticles formed in Ar ambience increases with increasing pressure, while an opposite trend was observed for the nanoparticles produced in N 2 and He ambiences. However, the physics behind this opposite trend seems unclear. In this work, we have investigated the probable mechanism behind the opposite trend in particle size with pressure of different gases and understand the mechanism of nanoparticle formation in wire explosion process. The experiment was carried out to investigate the effect of ambient gas species (Ar and N 2 ) and pressure on arc plasma formation and its corresponding effects on the characteristics of the produced nanoparticles in wire explosion process. Our results show that the arc plasma formation is probably the mechanism that may account for the opposite trend of particle size with pressure of different gases. -- Highlights: ► Cu nanoparticles have been synthesized by wire explosion technique. ► Investigate the effect of the ambient gas species and pressure. ► Arc plasma formation in wire explosion process is investigated. ► Arc plasma formation plays a crucial role in characteristic of the nanoparticles

  11. Enhancing wire-composite bond strength of bonded retainers with wire surface treatment.

    Science.gov (United States)

    Oesterle, L J; Shellhart, W C; Henderson, S

    2001-06-01

    Bonded orthodontic retainers with wires embedded in composite resin are commonly used for orthodontic retention. The purpose of this study was to test, in vitro, various wire surface treatments to determine the optimal method of enhancing the wire-composite bond strength. Coaxial wires and stainless steel wires with different surface treatments were bonded to bovine enamel and then pulled along their long axes with an Instron universal testing machine. Wire surface treatments included placing a right-angle bend in the wire, microetching the wire, and treating the wire with adhesion promoters; combinations of treatments were also examined. The results demonstrated a 24-fold increase in the wire-composite bond strength of wire that was microetched (sandblasted), compared with that of untreated straight wire. The difference between the amount of force required to break the bond produced by microetching alone (246.1 +/- 46.0 MPa) and that required for the bonds produced by the retentive bend (87.8 +/- 16.3 MPa), the adhesion promoters (silane, 11.0 +/- 3.1 MPa; Metal Primer, 28.5 +/- 15.8 MPa), or for any combination of surface treatments, was statistically significant. Microetching a stainless steel wire produced a higher wire-composite bond strength than that obtained from a coaxial wire (113.5 +/- 27.5 MPa). The results of this study indicate that microetching or sandblasting a stainless steel wire significantly increases the strength of the wire-composite bond.

  12. Hydrogenated Nanocrystalline Silicon Thin Films Prepared by Hot-Wire Method with Varied Process Pressure

    Directory of Open Access Journals (Sweden)

    V. S. Waman

    2011-01-01

    Full Text Available Hydrogenated nanocrystalline silicon films were prepared by hot-wire method at low substrate temperature (200∘C without hydrogen dilution of silane (SiH4. A variety of techniques, including Raman spectroscopy, low angle X-ray diffraction (XRD, Fourier transform infrared (FTIR spectroscopy, atomic force microscopy (AFM, and UV-visible (UV-Vis spectroscopy, were used to characterize these films for structural and optical properties. Films are grown at reasonably high deposition rates (>15 Å/s, which are very much appreciated for the fabrication of cost effective devices. Different crystalline fractions (from 2.5% to 63% and crystallite size (3.6–6.0 nm can be achieved by controlling the process pressure. It is observed that with increase in process pressure, the hydrogen bonding in the films shifts from Si–H to Si–H2 and (Si–H2n complexes. The band gaps of the films are found in the range 1.83–2.11 eV, whereas the hydrogen content remains <9 at.% over the entire range of process pressure studied. The ease of depositing films with tunable band gap is useful for fabrication of tandem solar cells. A correlation between structural and optical properties has been found and discussed in detail.

  13. Wire Integrity Field Survey of USAF Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...upgrades and modifications . Aging Mechanisms All wiring systems are subject to aging during their normal service life. Aging is the progressive

  14. HYBASE : HYperspectral BAnd SElection

    NARCIS (Netherlands)

    Schwering, P.B.W.; Bekman, H.H.P.T.; Seijen, H.H. van

    2009-01-01

    Band selection is essential in the design of multispectral sensor systems. This paper describes the TNO hyperspectral band selection tool HYBASE. It calculates the optimum band positions given the number of bands and the width of the spectral bands. HYBASE is used to assess the minimum number of

  15. A new method for cerclage wire fixation to maximal pre-tension with minimal elongation to failure.

    Science.gov (United States)

    Meyer, Dominik C; Ramseier, Leo E; Lajtai, Georg; Nötzli, Hubert

    2003-12-01

    To develop and test a new cerclage wire tightening technique, yielding reproducibly maximal pre-tension, load to failure and minimal elongation to failure of the wire junction. Laboratory bench study. Cerclage wire fixation is difficult to perform by hand with reproducible quality and tightening tension, which are required for optimal performance. With the new technique, 1, 1.25 and 1.5 mm steel wires were passed through a 9 x 18 mm steel tube, grasped using a modified ASIF wire-tightener and tightened by twisting until spontaneous failure of the wires in the tube. These fixations were compared to wires pre-tightened by hand to controlled high or low pre-tension using the simple twist, the knot twist and twist secured against untwisting, loaded to failure on a testing machine. The tests assessed pre-tension, ultimate failure load and elongation to failure. Wire twists performed with the new technique were always perfectly symmetrical and may be tightened to maximal pre-tension without weakening of the wire. The twist secured against untwisting combined high stiffness with high failure load. The knot twist elongates to an unacceptable degree, unlike the secured twist. The simple twist untwists under little tension. The new technique allows to obtain maximal pre-tension and thus minimal elongation to failure of simple wire twists, without having to worry about breaking the wire at the base of the twist due to over-tightening. Cerclage wire fixation is an effective and cheap method to perform osteosynthesis. For adequate performance, maximal pre-tension, symmetrical twisting and high load to failure are necessary. The here presented technique combines all of these pre-requisites in a simple fashion.

  16. Separate vertical wiring for the fixation of comminuted fractures of the inferior pole of the patella.

    Science.gov (United States)

    Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo; Yang, Kyu Hyun

    2014-05-01

    Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing.

  17. Wavelet transform of signal for enhancement of SNR in wire rope inspection

    Science.gov (United States)

    Lunin, V.; Barat, V.

    2002-05-01

    In magnetic testing of steel wire rope the MFL signals of broken wires may be corrupted by background noise arising from the probe lift-off, vibration and white noise, resulting in unreliable detection and inaccurate characterization of rope weakness. In this paper, a signal processing technique is presented to reduce this background noise by the use of a wavelet transform. The results of processing signals from testing rope pieces show that proposed technique is effective for extracting defect signals.

  18. Put Your Cable Wiring to the Test.

    Science.gov (United States)

    Day, C. William

    2001-01-01

    Discusses why schools and universities should use testing procedures in any wire bid specification for cable wiring and also know how experienced the installers are in testing and installing structured cabling systems. Key cabling terms are included. (GR)

  19. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  20. Clinical bending of nickel titanium wires

    OpenAIRE

    Stephen Chain; Priyank Seth; Namrata Rastogi; Kenneth Tan; Mayank Gupta; Richa Singh

    2015-01-01

    Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our invento...

  1. Towards Unconventional Applications of Wire Bonding

    OpenAIRE

    Schröder, Stephan

    2018-01-01

    This thesis presents novel heterogeneous integration approaches of wire materials to fabricated and package MEMS devices by exploring unconventional applications of wire bonding technology. Wire bonding, traditionally endemic in the realm of device packaging to establish electrical die-to-package interconnections, is an attractive back-end technology, offering promising features, such as high throughput, flexibility and placement accuracy. Exploiting the advantages of state-of-the-art wire bo...

  2. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  3. Vocational Preparation Curriculum: Electrical Wiring.

    Science.gov (United States)

    Usoro, Hogan

    This document is a curriculum guide for instructors teaching vocational preparation for electrical wiring to special needs students. The purpose of the curriculum guide is to provide minimum skills for disadvantaged and handicapped students entering the mainstream; to supplement vocational skills of those students already in a regular training…

  4. Health care's 100 most wired.

    Science.gov (United States)

    Solovy, A; Serb, C

    1999-02-01

    They're wired all right, and America's 100 most techno-savvy hospitals and health systems share one more thing: a commitment to using technology to link with employees, patients, suppliers, and insurers. "We want to be a health care travel agency for our community," says one chief information officer. "And we see Internet technology as a key."

  5. Studying an inexpensive wire discone antenna as a candidate for TVWS spectrum monitoring / sensing

    CSIR Research Space (South Africa)

    Lysko, AA

    2014-10-01

    Full Text Available . Correctly identifying available TVWS bands is critical for success of TVWS based broadband communications, not causing interference to reception of TV broadcast by TV receivers. This paper discusses side effects encountered with a popular design of a wire...

  6. Wired or Wireless Internet?

    DEFF Research Database (Denmark)

    Gimpel, Gregory

    2010-01-01

    This paper finds that network externalities play a minimal role in the choice of internet access technology. Potential adopters of mobile laptop internet view broadband technology as a black box, the technological details of which donot matter. The study uses qualitative techniques to explore how...... the speed of technological obsolescence, market share dominance, and the black boxing of technology influence consumer intention to adopt WiMax and 3G wireless internet for their laptop computers. The results, implications for industry, and areas for further research are discussed....

  7. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  8. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  9. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  10. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the United...

  11. Stochastic quantum confinement in nanocrystalline silicon layers: The role of quantum dots, quantum wires and localized states

    Energy Technology Data Exchange (ETDEWEB)

    Ramírez-Porras, A., E-mail: aramirez@fisica.ucr.ac.cr [Centro de Investigación en Ciencia e Ingeniería de Materiales (CICIMA), Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica); Escuela de Física, Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica); García, O. [Escuela de Física, Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica); Escuela de Química, Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica); Vargas, C. [Escuela de Física, Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica); Corrales, A. [Escuela de Física, Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica); Escuela de Química, Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica); Solís, J.D. [Escuela de Física, Universidad de Costa Rica, San Pedro de Montes de Oca 11501 (Costa Rica)

    2015-08-30

    Highlights: • PL spectra of porous silicon samples have been studied using a stochastic model. • This model can deconvolute PL spectra into three components. • Quantum dots, quantum wires and localized states have been identified. • Nanostructure diameters are in the range from 2.2 nm to 4.0 nm. • Contributions from quantum wires are small compared to the others. - Abstract: Nanocrystallites of Silicon have been produced by electrochemical etching of crystal wafers. The obtained samples show photoluminescence in the red band of the visible spectrum when illuminated by ultraviolet light. The photoluminescence spectra can be deconvolved into three components according to a stochastic quantum confinement model: one band coming from Nanocrystalline dots, or quantum dots, one from Nanocrystalline wires, or quantum wires, and one from the presence of localized surface states related to silicon oxide. The results fit well within other published models.

  12. The Wire Flyer Towed Profiling System

    Science.gov (United States)

    Roman, C.; Ullman, D. S.; Hebert, D.

    2016-02-01

    The Wire Flyer is an autonomous profiling vehicle that slides up and down a standard towed cable in a controlled manner using the lift created by wing foils. The vehicle is able to create high resolution water-column sections within a specified depth band in an automated manner. The Wire Flyer is different than standard undulating tow bodies in that it decouples the vehicle's motion from the tow cable dynamics. Due to this separation the vehicle is able to profile with nearly 1:1 horizontal to vertical motion. A heavy depressor weight is fixed to the end of the cable and the cable shape remains relatively static during operation. The vehicle uses a closed loop wing angle controller to achieve desired vertical velocities between 0 and 2.5 m/s for ship speeds between 1.5 and 2.5 m/s. During typical operations, updated commands and condensed data samples can be sent to and from the vehicle via an acoustic modem to adjust the profiling pattern to ensure the desired coverage. The current 1000 meter rated vehicle is equipped with a SBE 49 FastCAT CTD, and can carry additional sensors for oxygen, Chlorophyll fluorescence and acoustic echosounding. Results showing the vehicle performance as well as the quality of the processed CTD data will be presented from three test cruises to the New England Shelf Break Front. Many shallow and deep sections were obtained with horizontal resolution that is not otherwise achievable with undulating tow bodies, underway CTDs, standard CTD tow-yos, gliders or free swimming AUVs. A typical survey at ship speeds of 3-4 knots can profile over a depth band between 200 and 600 meters depth with a repeat cycle length of less than 1 km. The vehicle concept is depth independent and could work with a full ocean depth design. Application areas for the system include sub-meso scale observations of fronts, vent and seep plumes, oxygen minimum layers, mixing and mid-water bioacoustics.

  13. PEDOT:PSS "Wires" Printed on Textile for Wearable Electronics.

    Science.gov (United States)

    Guo, Yang; Otley, Michael T; Li, Mengfang; Zhang, Xiaozheng; Sinha, Sneh K; Treich, Gregory M; Sotzing, Gregory A

    2016-10-03

    Herein, the fabrication of all-organic conductive wires is demonstrated by utilizing patterning techniques such as inkjet printing and sponge stencil to apply poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS) onto nonwoven polyethylene terephthalate (PET) fabric. The coating of the conducting polymer is only present on the surface of the substrate (penetration depth ∼ 200 μm) to retain the functionality and wearability of the textile. The wires fabricated by different patterning techniques provide a wide range of resistance, i.e., tens of kΩ/□ to less than 2 Ω/□ that allows the resistance to be tailored to a specific application. The sheet resistance is measured to be as low as 1.6 Ω/□, and the breakdown current is as high as 0.37 A for a 1 mm wide line. The specific breakdown current exceeds the previously reported values of macroscopic carbon nanotube based materials. Simple circuits composed of the printed wires are demonstrated, and resistance of the circuit from the measurement agrees with the calculated value based on Kirchhoff's rules. Additionally, the printed PEDOT:PSS wires show less than 6.2% change in sheet resistance after three washing and drying cycles using detergent.

  14. Energetics and electronic properties of Pt wires of different topologies on monolayer MoSe{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Jamdagni, Pooja, E-mail: j.poojaa1228@gmail.com; Ahluwalia, P. K. [Physics Department, Himachal Pradesh University, Shimla, Himachal Pradesh, India 171005 (India); Kumar, Ashok [Centre for Physical Sciences, School of Basic and Applied Sciences, Central University of Panjab, Bathinda, India, 151001 (India); Thakur, Anil [Physics Department, Govt. Collage Solan, Himachal Pradesh, India, 173212 (India); Pandey, Ravindra [Physics Department, Michigan Technological University, Houghton (United States)

    2016-05-23

    The energetics and electronic properties of different topology of Pt wires including linear, zigzag and ladder structures on MoSe{sub 2} monolayer have been investigated in the framework of density functional theory (DFT). The predicted order of stability of Pt wire on MoSe{sub 2} monolayer is found to be: linear > ladder > zigzag. Pt wires induce states near the Fermi level of MoSe{sub 2} that results into metallic characteristics of Pt-wire/MoSe{sub 2} assembled system. Valence band charge density signifies most of the contribution from Pt atoms near the Fermi energy of assembled wire/MoSe{sub 2} system. These findings are expected to be important for the fabrication of devices based on MoSe{sub 2} layers for flexible nanoelectronics.

  15. Proportional counters aged anode wire recovering using an 80%CF4 + 20%CO2 gas mixture

    CERN Document Server

    Gavrilov, Gennady; Conti, Richard; Fetisov, Andrey; Maysuzenko, Dmitry; Shvecova, Natalia; Vakhtel, Victor

    2011-01-01

    A technique to recover a gas proportional counter having an aged anode wire using a glow discharge in an 80%CF4 + 20%CO2 gas mixture has been developed and tested. Studies of aging effects were carried out under sustained irradiation by an intense 90Sr -source of the straw proportional counters operated with a 60%Ar + 30%CO2 + 10%CF4 gas mixture. Special attention was paid to the aging mechanism of the anode wires. Our experience showed that using a given gas mixture the swelling of the anode wires is a typical mode of aging that leads to degradation of the gas gain. The proposed method of recovery provided a complete restoration of the gas gain and the signal amplitude in the damaged zone of the wire. SEM/XEM analysis confirmed successful cleaning WOx deposits from the wire surface. The application of this method to recover the aged gaseous detectors in real experimental conditions is discussed.

  16. The Strengthening Effect of Phase Boundaries in a Severely Plastically Deformed Ti-Al Composite Wire

    Directory of Open Access Journals (Sweden)

    Tom Marr

    2014-02-01

    Full Text Available An accumulative swaging and bundling technique is used to prepare composite wires made of Ti and an Al alloy. These wires show reasonable higher yield stresses than expected from the pure material flow curves. The additional strengthening in the composite is analyzed using nanoindentation measurements, tensile testings and investigations of the microstructure. In addition, these properties are analyzed in relation to the fracture surface of the mechanically tested wires. Additional strengthening due to the presence of phase boundaries could be verified. Indications for residual stresses are found that cause a global hardness gradient from the center to the wire rim. Finally, the yield stress of the wires are calculated based on local hardness measurements.

  17. Results of stretched wire field integral measurements on the mini-undulator magnet - comparison of results obtained from circular and translational motion of the integrating wire

    International Nuclear Information System (INIS)

    Solomon, L.

    1998-05-01

    Measurements of the multipole content of the Mini-Undulator magnet have been made with two different integrating wire techniques. Both measurements used 43 strand Litz wire stretched along the length of the magnet within the magnet gap. In the first technique, the wire motion was purely translational, while in the second technique the wire was moved along a circular path. The induced voltage in the Litz wire was input into a Walker integrator, and the integrator output was analyzed as a function of wire position for determination of the multipole content of the magnetic field. The mini-undulator magnet is a 10 period, 80 mm per period hybrid insertion device. For all the data contained herein the magnet gap was set at 49 mm. In the mini-undulator magnet, the iron poles are 18mm x 32mm x 86 mm, and the Samarium Cobalt permanent magnet blocks are 22mm x 21mm x 110mm. For this magnet, which is a shortened prototype for the NSLS Soft X-Ray Undulator Magnet, the undulator parameter K = 0.934 B (Tesla)λ(cm), and B(tesla) = 0.534/sinh(πGap/λ). At a gap of 49 mm, the magnetic field is 1590 Gauss

  18. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    Science.gov (United States)

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  19. Wiring Economy of Pyramidal Cells in the Juvenile Rat Somatosensory Cortex.

    Science.gov (United States)

    Anton-Sanchez, Laura; Bielza, Concha; Larrañaga, Pedro; DeFelipe, Javier

    2016-01-01

    Ever since Cajal hypothesized that the structure of neurons is designed in such a way as to save space, time and matter, numerous researchers have analyzed wiring properties at different scales of brain organization. Here we test the hypothesis that individual pyramidal cells, the most abundant type of neuron in the cerebral cortex, optimize brain connectivity in terms of wiring length. In this study, we analyze the neuronal wiring of complete basal arborizations of pyramidal neurons in layer II, III, IV, Va, Vb and VI of the hindlimb somatosensory cortical region of postnatal day 14 rats. For each cell, we search for the optimal basal arborization and compare its length with the length of the real dendritic structure. Here the optimal arborization is defined as the arborization that has the shortest total wiring length provided that all neuron bifurcations are respected and the extent of the dendritic arborizations remain unchanged. We use graph theory and evolutionary computation techniques to search for the minimal wiring arborizations. Despite morphological differences between pyramidal neurons located in different cortical layers, we found that the neuronal wiring is near-optimal in all cases (the biggest difference between the shortest synthetic wiring found for a dendritic arborization and the length of its real wiring was less than 5%). We found, however, that the real neuronal wiring was significantly closer to the best solution found in layers II, III and IV. Our studies show that the wiring economy of cortical neurons is related not to the type of neurons or their morphological complexities but to general wiring economy principles.

  20. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  1. Emittance growth due to Tevatron flying wires

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M; Eddy, Nathan

    2004-06-01

    During Tevatron injection, Flying Wires have been used to measure the transverse beam size after each transfer from the Main Injector in order to deduce the transverse emittances of the proton and antiproton beams. This amounts to 36 + 9 = 45 flies of each of 3 wire systems, with an individual wire passing through each beam bunch twice during a single ''fly''. below they estimate the emittance growth induced by the interaction of the wires with the particles during these measurements. Changes of emittance from Flying Wire measurements conducted during three recent stores are compared with the estimations.

  2. Reduction of Gas Bubbles and Improved Critical Current Density in Bi-2212 Round Wire by Swaging

    CERN Document Server

    Jiang, J; Huang, Y; Hong, S; Parrell, J; Scheuerlein, C; Di Michiel, M; Ghosh, A; Trociewitz, U; Hellstrom, E; Larbalestier, D

    2013-01-01

    Bi-2212 round wire is made by the powder-in-tube technique. An unavoidable property of powder-in-tube conductors is that there is about 30% void space in the as-drawn wire. We have recently shown that the gas present in the as-drawn Bi-2212 wire agglomerates into large bubbles and that they are presently the most deleterious current limiting mechanism. By densifying short 2212 wires before reaction through cold isostatic pressing (CIPping), the void space was almost removed and the gas bubble density was reduced significantly, resulting in a doubled engineering critical current density (JE) of 810 A/mm2 at 5 T, 4.2 K. Here we report on densifying Bi-2212 wire by swaging, which increased JE (4.2 K, 5 T) from 486 A/mm2 for as-drawn wire to 808 A/mm2 for swaged wire. This result further confirms that enhancing the filament packing density is of great importance for making major JE improvement in this round-wire magnet conductor.

  3. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  4. Sintered wire cesium dispenser photocathode

    Science.gov (United States)

    Montgomery, Eric J; Ives, R. Lawrence; Falce, Louis R

    2014-03-04

    A photoelectric cathode has a work function lowering material such as cesium placed into an enclosure which couples a thermal energy from a heater to the work function lowering material. The enclosure directs the work function lowering material in vapor form through a low diffusion layer, through a free space layer, and through a uniform porosity layer, one side of which also forms a photoelectric cathode surface. The low diffusion layer may be formed from sintered powdered metal, such as tungsten, and the uniform porosity layer may be formed from wires which are sintered together to form pores between the wires which are continuous from the a back surface to a front surface which is also the photoelectric surface.

  5. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  6. Wear of dragline wire ropes

    Energy Technology Data Exchange (ETDEWEB)

    Dayawansa, D.; Kuruppu, M.; Mashiri, F.; Bartosiewicz, H. [Monash University (Caulfield Campus), Caulfield East, Vic. (Australia). Department of Mechanical Engineering,

    2005-07-01

    Wire ropes are one of the most heavily used components in a dragline. Hoist ropes are subjected to fatigue due to the cyclic nature of load handling as well as due to rope bending over the sheaves and the drum under load. This leads to wire breaks due to fatigue. Accumulation of a number of wire breaks close to each other can have a detrimental effect on the rope. Furthermore, to allow for the increasing demand for higher load capacity coupled with the inconvenience of having very large ropes, the factor of safety is often compromised, which increases the wear rate. Drag ropes are also subjected to heavy loads. More importantly, they are allowed to drag along the rough mine surface subjecting them to external physical abrasion. This makes the life of drag ropes one of the lowest among those used in a dragline. Suspension and IBS ropes are relatively uniformly loaded during their regular usage although they need to withstand dynamic load cycles as well as bending. Hence they tend to last for a number of years on average. The paper analyses the wear types and their severity of each of these rope applications, and suggests methods to determine rope wear rates and the resulting rope life. The paper further gives suggestions for good operating and maintenance practice that can extend the rope life and help reduce the large expenditure associated with every major rope change in a dragline. 6 refs., 8 figs., 1 tab.

  7. Tandem solar cells deposited using hot-wire chemical vapor deposition

    NARCIS (Netherlands)

    Veen, M.K. van

    2003-01-01

    In this thesis, the application of the hot-wire chemical vapor deposition (HWCVD) technique for the deposition of silicon thin films is described. The HWCVD technique is based on the dissociation of silicon-containing gasses at the catalytic surface of a hot filament. Advantages of this technique

  8. [Acute anterior cruciate ligament repair with combined intra- and extra-articular reconstruction using an iliotibial band with the modified MacIntosh technique: a five-year follow-up study of 50 pivoting sport athletes].

    Science.gov (United States)

    Schlatterer, B; Jund, S; Delépine, F; Razafindratsiva, C; de Peretti, F

    2006-12-01

    Comparisons have been often made between bone-tendon-bone plasty and hamstring tendon four-strand plasty. Whether a lateral tenodesis should be associated with the intra-articular reconstruction and the appropriate time between the accident and the repair remain two topics of debate. We present results obtained in a consecutive series of 50 pivoting sport atheletes reviewed retrospectively. These patients had been treated within eight days of trauma with a modified MacIntosh technique using an iliotibial band. This technique enables lateral tenodesis and reconstruction of the central pivot with only one harvesting site. We searched for responses to two questions: are our results comparable to those in other published series? could this operation be warranted as an emergency procedure? Fifty patients from a consecutive retrospective series of 62 patients (eight lost to follow-up and four excluded from the analysis) were reviewed by an independent observer at mean follow-up of 5.2 years (range 54.4 to 86.4 months). The ARPEGE and IKDC scoring systems were used. An isokinetic assessment was obtained in 38 patients at one year. The reconstruction technique used an iliotibial band measuring 40-45 mm in width. The lateral reconstruction consisted in section then translation of the lateral intermuscular partition. The overall outcome was scored as follows: IKDC A 38%, B 46%, C 12%, D 4%. Mean residual differential laxity (KT 1000) was 1.86+/-1.74 assessed manually with a negative Lachman in 48% of knees. 88% of the positive tests had been neutralized. Early anatomic failure was noted in two knees with recurrent traumatic tears at 25 and 38 months. Using the ARPEGE scoring system, outcome was excellent in 38%, good in 46%, fair in 12% and poor in 4%. At last follow-up, the level of sports activities was unchanged in 33 patients. Irreducible flexion measuring more than 5 degrees was noted in two patients, and a deficit in flexion greater than 20 degrees in three. One female

  9. Propagation of Ultrasonic Guided Waves in Composite Multi-Wire Ropes

    Directory of Open Access Journals (Sweden)

    Renaldas Raisutis

    2016-06-01

    Full Text Available Multi-wire ropes are widely used as load-carrying constructional elements in bridges, cranes, elevators, etc. Structural integrity of such ropes can be inspected by using non-destructive ultrasonic techniques. The objective of this work was to investigate propagation of ultrasonic guided waves (UGW along composite multi-wire ropes in the cases of various types of acoustic contacts between neighboring wires and the plastic core. The modes of UGW propagating along the multi-wire ropes were identified using modelling, the dispersion curves were calculated using analytical and semi-analytical finite element (SAFE techniques. In order to investigate the effects of UGW propagation, the two types of the acoustic contact between neighboring wires were simulated using the 3D finite element method (FE as well. The key question of investigation was estimation of the actual boundary conditions between neighboring wires (solid or slip and the real depth of penetration of UGW into the overall cross-section of the rope. Therefore, in order to verify the results of FE modelling, the guided wave penetration into strands of multi-wire rope was investigated experimentally. The performed modelling and experimental investigation enabled us to select optimal parameters of UGW to be used for non-destructive testing.

  10. Effects of Oxygen, Nitrogen and Fluorine on the Crystallinity of Tungsten by Hot-Wire Assisted ALD

    NARCIS (Netherlands)

    Yang, Mengdi; Aarnink, Antonius A.I.; Wolters, Rob A. M.; Schmitz, Jurriaan; Kovalgin, Alexey Y.

    2017-01-01

    A heated tungsten filament (wire) is well known to generate atomic hydrogen (at-H) by catalytically cracking molecular hydrogen (H2) upon contact. This mechanism is employed in our work on hot-wire (HW) assisted atomic layer deposition (HWALD), a novel energy-enhancement technique. HWALD has been

  11. Radiology of vertical banded gastroplasty

    International Nuclear Information System (INIS)

    Leekam, R.N.; Deitel, M.; Shankar, L.; Salsberg, B.

    1987-01-01

    Vertical banded gastroplasty is now the most common procedure for the surgical treatment of obesity. In the past 4 years 120 patients have been referred for radiologic examination. This exhibit describes the normal and abnormal findings in many of these patients. The authors divided radiologic abnormalities into three groups: abnormalities of the partition, abnormalities of the banded channel, and ulcers and extragastric leaks. The authors' examination technique has been adapted from those described by others, our important addition being the preliminary precontrast film, on which the staple lines can be examined. This has proved most effective in the detection of partition defects

  12. Closure of oroantral fistula using titanium plate with transalveolar wiring.

    Science.gov (United States)

    Ahmed, Wael Mohamed Said

    2015-03-01

    Alloplastic materials such as tantalum, gold plates and foils, hydroxyapatite blocks have been used for closure of oroantral fistula (OAF). However, these materials are not widely accepted in routine surgical closure of OAF due to cost, difficult handling, increased rate of infection, and exfoliation. To overcome the above drawbacks this study aimed to use titanium plates (0.3 mm) with transalveolar wiring fixation for closure of OAF. Ten patients with OAFs who consented to undergo this trial were selected and treated under an outpatient basis in the Oral Surgery Department, Faculty of Dentistry, Mansoura University, Egypt. All OAFs were successfully treated with no eventful complications. This study concludes that titanium plates with transalveolar wiring fixation is an excellent technique for closure of OAF. The high success rate with this technique warrants its use for closure of OAF.

  13. Thermoelectric properties of the Bi-15 at%Sb wires in weak magnetic field

    International Nuclear Information System (INIS)

    Popov, I.A.

    2011-01-01

    Full text: At concentration Sb (0.08 1-x Sb x is the semiconductor with inverted - band specter. In such nanowires with the inverted spectrum, can be realized of a topological insulator (TI) state. Long individual single-crystal Bi-15at%Sb nanowires in glass capillary with diameters 0.1mkm-2mkm were fabricated by liquid phase casting. Multiple horizontal zone recrystallization of the nanowires was used for the homogenization of wires and to improve their structural perfection. The measurement the angular rotation diagrams transverse [H perpendicular I] magnetoresistance in a weak magnetic field at 300 K and 77 K have allowed to conclude that Bi 1-x Sb x wires all composition and diameter had same orientation (1011)- along the wire axis. In this case value the energy gap is approximately 25 meV. As it has been shown at realization of quantum dimensional effect, in semiconductor Bi-Sb wires, the gap should increase. In thin Bi-15at%Sb wires we observed adverse effect. It is visible, that at temperatures T 2 σ depending on diameter of wires, structure, temperature and a magnetic field is calculated. In connection with topological insulators, we will discuss the effect of the surface state in the thermoelectric properties. (author)

  14. Correlated electron phenomena in ultra-low disorder quantum wires

    International Nuclear Information System (INIS)

    Reilly, D.J.; Facer, G.R.; Dzurak, A.S.; Kane, B.E.; Clark, R.G.; Lumpkin, N.E.

    1999-01-01

    Full text: Quantum point contacts in the lowest disorder HEMTs display structure at 0.7 x 2e 2 /h, which cannot be interpreted within a single particle Landauer model. This structure has been attributed to a spontaneous spin polarisation at zero B field. We have developed novel GaAs/AlGaAs enhancement mode FETs, which avoid the random impurity potential present in conventional MODFET devices by using epitaxially grown gates to produce ultra-low-disorder QPCs and quantum wires using electron beam lithography. The ballistic mean free path within these devices exceeds 160 μm 2 . Quantum wires of 5 μm in length show up to 15 conductance plateaux, indicating that these may be the lowest-disorder quantum wires fabricated using conventional surface patterning techniques. These structures are ideal for the study of correlation effects in QPCs and quantum wires as a function of electron density. Our data provides strong evidence that correlation effects are enhanced as the length of the 1D region is increased and also that additional structure moves close to 0.5 x 2e 2 /h, the value expected for an ideal spin-split 1D level

  15. Quench detection method for 2G HTS wire

    International Nuclear Information System (INIS)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V

    2010-01-01

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  16. Quench detection method for 2G HTS wire

    Energy Technology Data Exchange (ETDEWEB)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V, E-mail: maxmarche@gmail.co, E-mail: yxie@superpower-inc.co [SuperPower, Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States)

    2010-03-15

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  17. Positioning and joining of organic single-crystalline wires

    Science.gov (United States)

    Wu, Yuchen; Feng, Jiangang; Jiang, Xiangyu; Zhang, Zhen; Wang, Xuedong; Su, Bin; Jiang, Lei

    2015-01-01

    Organic single-crystal, one-dimensional materials can effectively carry charges and/or excitons due to their highly ordered molecule packing, minimized defects and eliminated grain boundaries. Controlling the alignment/position of organic single-crystal one-dimensional architectures would allow on-demand photon/electron transport, which is a prerequisite in waveguides and other optoelectronic applications. Here we report a guided physical vapour transport technique to control the growth, alignment and positioning of organic single-crystal wires with the guidance of pillar-structured substrates. Submicrometre-wide, hundreds of micrometres long, highly aligned, organic single-crystal wire arrays are generated. Furthermore, these organic single-crystal wires can be joined within controlled angles by varying the pillar geometries. Owing to the controllable growth of organic single-crystal one-dimensional architectures, we can present proof-of-principle demonstrations utilizing joined wires to allow optical waveguide through small radii of curvature (internal angles of ~90–120°). Our methodology may open a route to control the growth of organic single-crystal one-dimensional materials with potential applications in optoelectronics. PMID:25814032

  18. Wire system aging assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.; Nordlund, A.

    2006-04-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  19. Pseudo-creep in Shape Memory Alloy Wires and Sheets

    Science.gov (United States)

    Russalian, V. R.; Bhattacharyya, A.

    2017-10-01

    Interruption of loading during reorientation and isothermal pseudoelasticity in shape memory alloys with a strain arrest ( i.e., holding strain constant) results in a time-dependent evolution in stress or with a stress arrest ( i.e., holding stress constant) results in a time-dependent evolution in strain. This phenomenon, which we term as pseudo-creep, is similar to what was reported in the literature three decades ago for some traditional metallic materials undergoing plastic deformation. In a previous communication, we reported strain arrest of isothermal pseudoelastic loading, isothermal pseudoelastic unloading, and reorientation in NiTi wires as well as a rate-independent phase diagram. In this paper, we provide experimental results of the pseudo-creep phenomenon during stress arrest of isothermal pseudoelasticity and reorientation in NiTi wires as well as strain arrest of isothermal pseudoelasticity and reorientation in NiTi sheets. Stress arrest in NiTi wires accompanied by strain accumulation or recovery is studied using the technique of multi-video extensometry. The experimental results were used to estimate the amount of mechanical energy needed to evolve the wire from one microstructural state to another during isothermal pseudoelastic deformation and the difference in energies between the initial and the final rest state between which the aforementioned evolution has occurred.

  20. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk (Norway); Nordlund, A. [Chalmers Univ. of Technology (Sweden)

    2006-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  1. High speed photographic study of hot wire dynamic behavior

    Science.gov (United States)

    Sernas, V.; Murphy, A. J.

    1974-01-01

    Investigation of hot wire dynamic behavior under high-current heating aimed at a better understanding of the ignition process, using high-speed photographic techniques for visual observation of the bridgewire itself during high current heating. Tests were conducted with Tophet A bridgewires in an air environment, as well as in a cell of distilled water at room temperature, and with a boron-potassium perchlorate-Viton pyrotechnic against the bridgewire behind a Plexiglas window.

  2. Band structure of semiconductors

    CERN Document Server

    Tsidilkovski, I M

    2013-01-01

    Band Structure of Semiconductors provides a review of the theoretical and experimental methods of investigating band structure and an analysis of the results of the developments in this field. The book presents the problems, methods, and applications in the study of band structure. Topics on the computational methods of band structure; band structures of important semiconducting materials; behavior of an electron in a perturbed periodic field; effective masses and g-factors for the most commonly encountered band structures; and the treatment of cyclotron resonance, Shubnikov-de Haas oscillatio

  3. Electro-mechanics of drift tube wires

    International Nuclear Information System (INIS)

    Milburn, R.H.

    1997-01-01

    The position and stability of the sense wires in very long drift tubes are affected by both gravitational and electrostatic forces, as well as by the wire tension. For a tube to be used as an element of a high-resolution detector all these forces and their effects must be understood in appropriately precise detail. In addition, the quality control procedures applied during manufacture and detector installation must be adequate to ensure that the internal wire positions remain within tolerances. It may be instructive to practitioners to review the simple theory of a taut wire in the presence of anisotropic gravitational and electrostatic fields to illustrate the conditions for stability, the equilibrium wire displacement from straightness, and the effect of the fields on the mechanical vibration frequencies. These last may be used to monitor the wire configuration externally. A number of practical formulae result and these are applied to illustrative examples. (orig.)

  4. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  5. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  6. ECAE-processed Cu-Nb and Cu-Ag nanocomposite wires for pulse magnet applications

    International Nuclear Information System (INIS)

    Edgecumbe Summers, T.S.; Walsh, R.P.; Pernambuco-Wise, P.

    1997-01-01

    Cu-Nb and Cu-Ag nanocomposites have recently become of interest to pulse magnet designers because of their unusual combination of high strength with reasonable conductivity. In the as-cast condition, these conductors consist of two phases, one of almost pure Nb (or Ag) and the other almost pure Cu. When these castings are cold worked as in a wire-drawing operation for example, the two phases are drawn into very fine filaments which produce considerable strengthening without an unacceptable decrease in conductivity. Unfortunately, any increase in strength with operations such as wire drawing is accompanied by a reduction in the cross section of the billet, and thus far, no wires with strengths on the order of 1.5 GPa or more have been produced with cross sections large enough to be useful in magnet applications. Equal Channel Angular Extrusion (ECAE) is an innovative technique which allows for the refinement of the as-cast ingot structure without a reduction in the cross sectional dimensions. Samples processed by the ECAE technique prior to wire drawing should be stronger at a given wire diameter than those processed by wire drawing alone. The tensile properties of wire-drawn Cu-18%Nb and Cu-25%Ag both with and without prior ECAE processing were tested and compared at both room temperature and 77K. All samples were found to have resistivities consistent with their strengths, and the strengths of the ECAE-processed wires were significantly higher than their as-cast and drawn counterparts. Therefore, with ECAE processing prior to wire drawing, it appears to be possible to make high-strength conductors with adequately large cross sections for pulse magnets

  7. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  8. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  9. [Gastric band erosion: Alternative management].

    Science.gov (United States)

    Echaverry-Navarrete, Denis José; Maldonado-Vázquez, Angélica; Cortes-Romano, Pablo; Cabrera-Jardines, Ricardo; Mondragón-Pinzón, Erwin Eduardo; Castillo-González, Federico Armando

    2015-01-01

    Obesity is a public health problem, for which the prevalence has increased worldwide at an alarming rate, affecting 1.7 billion people in the world. To describe the technique employed in incomplete penetration of gastric band where endoscopic management and/or primary closure is not feasible. Laparoscopic removal of gastric band was performed in five patients with incomplete penetrance using Foley catheterization in the perforation site that could lead to the development of a gastro-cutaneous fistula. The cases presented include a leak that required surgical lavage with satisfactory outcome, and one patient developed stenosis 3 years after surgical management, which was resolved endoscopically. In all cases, the penetration site closed spontaneously. Gastric band erosion has been reported in 3.4% of cases. The reason for inserting a catheter is to create a controlled gastro-cutaneous fistula, allowing spontaneous closure. Various techniques have been described: the totally endoscopic, hybrid techniques (endoscopic/laparoscopic) and completely laparoscopic. A technique is described here that is useful and successful in cases where the above-described treatments are not viable. Copyright © 2015. Published by Masson Doyma México S.A.

  10. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  11. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  12. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  13. 47 CFR 76.804 - Disposition of home run wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  14. New constructions of wire ropes for the industry

    Directory of Open Access Journals (Sweden)

    ŠŠaderová Jana

    1996-03-01

    Full Text Available The wire ropes are used in different industrial fields. Their construction depends on the type of equipment and its purpose. Most frequently we meet with ropes at different transport and hoisting equipments and very freqently in the civil industry. For users characteristics are important which must meet requirements of the individual regulations and standards of the selection of wire ropes for the concrete equipment. The most important is the factor of safety being safeguarded by the corresponding bearing capacity of the rope. The service life of rope is interesting for the user, too, because of having an influence on the economy of the equipment on which the rope is working. These problems are solved by the grant project at our department . We are aimed at questions of the optimization of construction of wire rope with regard to their geometric construction and service life. Respectively on the basis of elaborated computer software eightstrand ropes of parallel construction were disigned and produced at the Drôtov ň a Hlohovec. The results of the fatigue tests confirmed their better qualitative properties, longer service life and economy advantages for users, too. Their using is possible and suitable on the new hoisting eguipment on the surface, in the undeground and in the hole drilling industry. By the application of the computer technique is also possible to improve the parametres of six-strands` construction of rope, the classic and parallel constructions, especially their bearing capacity. This fact follows from the knowledge that for the production of rope we use calculated diameters of wires, which secure better utilization of the metal cross-section of the wire ropes.

  15. Intra-wire resistance and AC loss in multi-filamentary MgB2 wires

    NARCIS (Netherlands)

    Zhou, Chao; Offringa, Wietse; Bergen, Anne-Henriette; Wessel, Wilhelm A.J.; Krooshoop, Hendrikus J.G.; Dhalle, Marc M.J.; Sumption, M.D.; Collings, E.W.; Rindfleisch, M.; Tomsic, M.; ten Kate, Herman H.J.; Nijhuis, Arend

    2013-01-01

    Intra-wire resistance and AC loss of various multi-filamentary MgB2 wires with filaments surrounded by Nb barriers have been measured and analyzed. The intra-wire resistance is measured with a direct four-probe voltage–current method at various temperatures. The AC loss is acquired by both vibrating

  16. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  17. Incidental finding of a left over guide wire on a positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yap, Kok Hooi; Lee, Phong Teck; Buch, Mamta; Rammohan, Kandadai Seshadri

    2012-12-15

    The Seldinger technique is commonly used cannulate vessels for radiographical procedures. Loss of a guide wire into the circulation is a rare and preventable complication. It is often noticed by chance during routine radiographs. However, there is a lack of reported cases of incidental fin dings of leftover guide wire on a PET scan. An intravascular foreign body should be retrieved as soon as the diagnosis is made, to prevent complications such as embolisation or vascular damage by fractured wires. Interventional radiology is the method of choice for retrieval. We report a rare case of the coincidental finding of a lost guide wire on a PET scan. A 37 year old man presented with psychotic episodes, thigh weakness, weight gain, increased appetite and leg cramps. He was subsequently diagnosed with cushing syndrome secondary to ectopic adrenocorticotropic secretion from a right lung tumour. He subsequently underwent a staging positron emission tomography (PET) scan. The lung tumour had no uptake on PET bit had increased activity uptake on octreotide scanning. These appearances were suggestive of with carcinoid tumour. The PET scan also revealed an incidental finding of a leftover guide wire used during peripheral inserted central catheter (PICC) recently. The wire extended from right atrium to inferior vena cava. It also showed a high uptake in the adrenal glands, indicating hyperplasia, which was most likely due to adrenocorticotropic hormone stimulation. He underwent a percutaneous wire retrieval via the right femoral vein in a cardiac catheterisation laboratory and was transferred to a thoracic surgical unit for lung tumor resection.

  18. Incidental finding of a left over guide wire on a positron emission tomography

    International Nuclear Information System (INIS)

    Yap, Kok Hooi; Lee, Phong Teck; Buch, Mamta; Rammohan, Kandadai Seshadri

    2012-01-01

    The Seldinger technique is commonly used cannulate vessels for radiographical procedures. Loss of a guide wire into the circulation is a rare and preventable complication. It is often noticed by chance during routine radiographs. However, there is a lack of reported cases of incidental fin dings of leftover guide wire on a PET scan. An intravascular foreign body should be retrieved as soon as the diagnosis is made, to prevent complications such as embolisation or vascular damage by fractured wires. Interventional radiology is the method of choice for retrieval. We report a rare case of the coincidental finding of a lost guide wire on a PET scan. A 37 year old man presented with psychotic episodes, thigh weakness, weight gain, increased appetite and leg cramps. He was subsequently diagnosed with cushing syndrome secondary to ectopic adrenocorticotropic secretion from a right lung tumour. He subsequently underwent a staging positron emission tomography (PET) scan. The lung tumour had no uptake on PET bit had increased activity uptake on octreotide scanning. These appearances were suggestive of with carcinoid tumour. The PET scan also revealed an incidental finding of a leftover guide wire used during peripheral inserted central catheter (PICC) recently. The wire extended from right atrium to inferior vena cava. It also showed a high uptake in the adrenal glands, indicating hyperplasia, which was most likely due to adrenocorticotropic hormone stimulation. He underwent a percutaneous wire retrieval via the right femoral vein in a cardiac catheterisation laboratory and was transferred to a thoracic surgical unit for lung tumor resection

  19. A High-Temperature Transient Hot-Wire Thermal Conductivity Apparatus for Fluids.

    Science.gov (United States)

    Perkins, R A; Roder, H M; Nieto de Castro, C A

    1991-01-01

    A new apparatus for measuring both the thermal conductivity and thermal diffusivity of fluids at temperatures from 220 to 775 K at pressures to 70 MPa is described. The instrument is based on the step-power-forced transient hot-wire technique. Two hot wires are arranged in different arms of a Wheatstone bridge such that the response of the shorter compensating wire is subtracted from the response of the primary wire. Both hot wires are 12.7 µm diameter platinum wire and are simultaneously used as electrical heat sources and as resistance thermometers. A microcomputer controls bridge nulling, applies the power pulse, monitors the bridge response, and stores the results. Performance of the instrument was verified with measurements on liquid toluene as well as argon and nitrogen gas. In particular, new data for the thermal conductivity of liquid toluene near the saturation line, between 298 and 550 K, are presented. These new data can be used to illustrate the importance of radiative heat transfer in transient hot-wire measurements. Thermal conductivity data for liquid toluene, which are corrected for radiation, are reported. The precision of the thermal conductivity data is ± 0.3% and the accuracy is about ±1%. The accuracy of the thermal diffusivity data is about ± 5%. From the measured thermal conductivity and thermal diffusivity, we can calculate the specific heat, C p , of the fluid, provided that the density is measured, or available through an equation of state.

  20. STRENGTHENING OF A REINFORCED CONCRETE BRIDGE WITH PRESTRESSED STEEL WIRE ROPES

    Directory of Open Access Journals (Sweden)

    Kexin Zhang

    2017-10-01

    Full Text Available This paper describes prestressed steel wire ropes as a way to strengthen a 20-year-old RC T-beam bridge. High strength, low relaxation steel wire ropes with minor radius, high tensile strain and good corrosion resistance were used in this reinforcement. The construction process for strengthening with prestressed steel wire ropes—including wire rope measuring, extruding anchor heads making, anchorage installing, tensioning steel wire ropes and pouring mortar was described. Ultimate bearing capacity of the bridge after strengthening was discussed based on the concrete structure theory. The flexural strength of RC T-beam bridges strengthened with prestressed steel wire ropes was governed by the failure of concrete crushing. To investigate effectiveness of the strengthening method, fielding-load tests were carried out before and after strengthening. The results of concrete strain and deflection show that the flexural strength and stiffness of the strengthened beam are improved. The crack width measurement also indicates that this technique could increase the durability of the bridge. Thus, this strengthened way with prestressed steel wire rope is feasible and effective.

  1. Comparison of PIV and Hot-Wire statistics of turbulent boundary layer

    International Nuclear Information System (INIS)

    Dróżdż, A; Uruba, V

    2014-01-01

    The paper shows a cross checking of turbulent boundary layer measurements using large field of view PIV and hot-wire anemometry techniques. The time-resolved PIV method was used for the experiments. The measuring plane was oriented perpendicularly to the wall and parallel to the mean flow. Hot wire measurement has been performed using the special probe with perpendicular hot wire. The HW point measurements were performed in the same place as PIV experiments. The hot-wire probe has the wire length of l + < 20 in considered range of Reynolds numbers. Various evaluation methods were applied on PIV data. The profiles of statistical characteristics of streamwise velocity components were evaluated from the data. Mean values, standard deviations as well as skewness and kurtosis coefficients were compared for a few values of Re θ . Reynolds number ranges from 1000 to 5500. The result shows that with the increasing Reynolds number the attenuation of fluctuations maximum in PIV measurements occurs with respect to Hot-Wire measurements, however representation of velocity fluctuations using the PIV method is satisfactory. The influence of wall-normal fluctuation component on Hot-Wire near wall peak was also investigated.

  2. Semiconductor Modeling Techniques

    CERN Document Server

    Xavier, Marie

    2012-01-01

    This book describes the key theoretical techniques for semiconductor research to quantitatively calculate and simulate the properties. It presents particular techniques to study novel semiconductor materials, such as 2D heterostructures, quantum wires, quantum dots and nitrogen containing III-V alloys. The book is aimed primarily at newcomers working in the field of semiconductor physics to give guidance in theory and experiment. The theoretical techniques for electronic and optoelectronic devices are explained in detail.

  3. The dynamics of a shear band

    Science.gov (United States)

    Giarola, Diana; Capuani, Domenico; Bigoni, Davide

    2018-03-01

    A shear band of finite length, formed inside a ductile material at a certain stage of a continued homogeneous strain, provides a dynamic perturbation to an incident wave field, which strongly influences the dynamics of the material and affects its path to failure. The investigation of this perturbation is presented for a ductile metal, with reference to the incremental mechanics of a material obeying the J2-deformation theory of plasticity (a special form of prestressed, elastic, anisotropic, and incompressible solid). The treatment originates from the derivation of integral representations relating the incremental mechanical fields at every point of the medium to the incremental displacement jump across the shear band faces, generated by an impinging wave. The boundary integral equations (under the plane strain assumption) are numerically approached through a collocation technique, which keeps into account the singularity at the shear band tips and permits the analysis of an incident wave impinging a shear band. It is shown that the presence of the shear band induces a resonance, visible in the incremental displacement field and in the stress intensity factor at the shear band tips, which promotes shear band growth. Moreover, the waves scattered by the shear band are shown to generate a fine texture of vibrations, parallel to the shear band line and propagating at a long distance from it, but leaving a sort of conical shadow zone, which emanates from the tips of the shear band.

  4. Effects of nanostructured, diamondlike, carbon coating and nitrocarburizing on the frictional properties and biocompatibility of orthodontic stainless steel wires.

    Science.gov (United States)

    Zhang, Hao; Guo, Shuyu; Wang, Dongyue; Zhou, Tingting; Wang, Lin; Ma, Junqing

    2016-09-01

    To evaluate and compare the effects of nanostructured, diamondlike, carbon (DLC) coating and nitrocarburizing on the frictional properties and biocompatibility of orthodontic stainless steel archwires. Plasma-enhanced chemical vapor deposition technology was applied to coat DLC films onto the surface of austenitic stainless steel wires, and salt-bath nitrocarburizing technology was employed to achieve surface hardening of other wires. Surface and cross-sectional characteristics, microhardness, modulus of elasticity, friction resistance, corrosion resistance, and cell toxicity of the modified and control wires were analyzed. The surfaces of the DLC-coated and nitrocarburized wires were both smooth and even. Compared with the control, the DLC-coated wires were increased in surface hardness 1.46 times, decreased in elastic modulus, reduced in kinetic friction coefficient by 40.71%, and decreased in corrosion current density by two orders of magnitude. The nitrocarburized wire was increased in surface hardness 2.39 times, exhibited an unchanged elastic modulus, demonstrated a decrease in maximum static friction force of 22.2%, and rose in corrosion current density two orders of magnitude. Cytotoxicity tests revealed no significant toxicity associated with the modified wires. DLC coating and nitrocarburizing significantly improved the surface hardness of the wires, reduced friction, and exhibited good biocompatibility. The nanostructured DLC coating provided excellent corrosion resistance and good elasticity, and while the nitrocarburizing technique substantially improved frictional properties, it reduced the corrosion resistance of the stainless steel wires to a lesser extent.

  5. Ab-initio study of encapsulated and functionalized silicon nanotube with a monoatomically thin Cu wire

    Energy Technology Data Exchange (ETDEWEB)

    Chandel, Surjeet Kumar; Ahluwalia, P. K.; Sharma, Raman [Department of Physics, Himachal Pradesh University, Shimla, Himachal Pradesh-171005 (India); Kumar, Arun, E-mail: arun242493@yahoo.com [Department of Physics, Govt. College Banjar, Kullu, Himachal Pradesh-175123 (India)

    2015-06-24

    First principle calculations based on DFT have been performed to study the interaction of monoatomically thin Cu wire with silicon nanotube in armchair configuration having chirality (6, 6) both by placing it inside (encapsulation) and outside (functionalisation) the tube. The lowest energy for positioning monoatomically thin Cu wire inside and outside surfaces of SiNT were found to possess cohesive energies of 4.03 eV and 4.02 eV respectively and hence the stability of both SiNTs is found to be almost same. However, From the electronic band structures study, the conductance in case of SiNT for the encapsulated and functionalized positioning of the Cu wire have been found to be 2G{sub 0} and 4G{sub 0} respectively showing enhanced conductance for the functionalized SiNT.

  6. EXPERIMENTAL DETERMINATION OF LONGITUDINAL COMPONENT OF MAGNETIC FLUX IN FERROMAGNETIC WIRE OF SINGLE-CORE POWER CABLE ARMOUR

    Directory of Open Access Journals (Sweden)

    I.A. Kostiukov

    2014-12-01

    Full Text Available A problem of determination of effective longitudinal magnetic permeability of single core power cable armour is defined. A technique for experimental determination of longitudinal component of magnetic flux in armour spiral ferromagnetic wire is proposed.

  7. Measure of thermal neutron flux in the IPEN/MB-01 reactor using 197 Au wire activation detectors

    International Nuclear Information System (INIS)

    Marques, Andre Luis Ferreira

    1995-01-01

    This dissertation has aimed at developing a neutron flux measurement technique by means of detectors activation analysis. The main task of this work was the implementation of this thermal neutron flux measurement technique, using gold wires as activation detectors in the IPEN/MB-01 reactor core. The neutron thermal flux spatial distribution was obtained by gold wire activation technique, with wire diameters of 0.125 mm and 0.250 mm in seven selected reactor experimental channels. The values of thermal flux were about 10 9 neutrons/cm 2 .s. This experiment has been the first one conducted with gold wires in the IPEN/MB-01 reactor, being this technique implemented for use by experiments in flux mapping of the core

  8. Wave-to-wire Modelling of Wave Energy Converters

    DEFF Research Database (Denmark)

    Ferri, Francesco

    different techniques to reduce the cost of energy are compared: the former maximises the system revenue (income) by acting on the control logic, while the second extends the first methods adding a penalty term due to the effect of the control logic on the structural design. Both methods are once more based...... applicable, efficient and reliable wave-to-wire model tool is needed. A wave-to-wire model identifies the relation from the source of energy of a particular location to the expected device productivity. The latter being expressed in terms of electricity fed into the grid. The model needs to output a coarse...... the best of what we have", the numerical model used is entirely based on well established methods. The experimental data is used as a check point to verify the direction of the numerical path. Second, shed light on what should be the objective of the sector: minimisation of the cost of energy. Two...

  9. Ti-Al Composite Wires with High Specific Strength

    Directory of Open Access Journals (Sweden)

    Ludwig Schultz

    2011-11-01

    Full Text Available An alternative deformation technique was applied to a composite made of titanium and an aluminium alloy in order to achieve severe plastic deformation. This involves accumulative swaging and bundling. Furthermore, it allows uniform deformation of a composite material while producing a wire which can be further used easily. Detailed analysis concerning the control of the deformation process, mesostructural and microstructural features and tensile testing was carried out on the as produced wires. A strong grain refinement to a grain size of 250–500 nm accompanied by a decrease in 〈111〉 fibre texture component and a change from low angle to high angle grain boundary characteristics is observed in the Al alloy. A strong increase in the mechanical properties in terms of ultimate tensile strength ranging from 600 to 930 MPa being equivalent to a specific strength of up to 223 MPa/g/cm3 was achieved.

  10. Long-Wearing Wire Guide For Welding Torch

    Science.gov (United States)

    Gutow, David A.; Burley, Richard K.; Gilbert, Jeffrey L.; Fogel, Irving

    1992-01-01

    Insert for wire-guide tube on tungsten/inert-gas welding apparatus extends life of guide tube and increases accuracy of weld. Hardened insert resists wear by sliding tungsten wire. Chamfer guides wire into insert.

  11. 29 CFR 1919.79 - Wire rope.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... recommended by the equipment or the wire rope manufacturer due to actual working condition requirements. In...

  12. Automatic inspection of railway overhead wires

    NARCIS (Netherlands)

    Smorenburg, C.; Valkenburg, A.L.G. van

    1988-01-01

    For the Netherlands railway company a system for inspection of the degree of wear of the contact wires is being developed. With an active sensor the reflective under-surface of the overhead wire is illuminated with a laserbeam and reflected radiation is detected by fast CCD detectors. With the

  13. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  14. WIRED magazine announces rave awards nominees

    CERN Multimedia

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  15. Hot-wire anemometer for spirography.

    Science.gov (United States)

    Plakk, P; Liik, P; Kingisepp, P H

    1998-01-01

    The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating principles and calibration procedure of the apparatus are described, and temperature compensation method is discussed. Frequency response is studied. It is shown that this hot-wire flow transducer satisfies common demands with respect to accuracy, response time and temperature variations.

  16. A Method for Avoiding Numerical Instability in FDTD-based Surge Simulations and its Application to Representation of Thin Wires

    Science.gov (United States)

    Tatematsu, Akiyoshi; Noda, Taku

    The FDTD (Finite Difference Time Domain) method, which is used for the computation of electromagnetic fields, is a useful tool for surge problems in three-dimensional arrangements, which cannot be rigorously treated by simulation methods such as EMTP (Electromagnetic Transients Programs) based on circuit theory. In the FDTD method, thin wires such as power lines are often represented by forcing the electric fields along the wires to zero. If a thin wire is represented in this way, its radius is determined by the size of the cells surrounding the wire. Although the technique for simulating an arbitrary radius has already been proposed, numerical instability often occurs in simulations when the wire radius is much smaller than the size of the cells surrounding the wire. As a conventional countermeasure against such numerical instability, the time discretization is often set to a smaller value than that based on Courant's condition. However, the smaller time discretization results in an increase in the calculation time. We propose a new technique for avoiding the numerical instability. Using this technique, in only a part of an analysis space where the numerical instability may occur, the time discretization is set to a value smaller than that based on Courant's condition, while the time discretization is set to a value close to that based on Courant's condition in the other part of the analysis space. We performed an FDTD-based simulation of a thin wire using the proposed numerical stabilization technique for validation.

  17. Shape memory alloys–characterization techniques

    Indian Academy of Sciences (India)

    The former transformation has been widely used in the applications like antenna deployment of satellite, aerospace couplings, orthodontic arch wires, medical guide wires for diagnostic and therapeutic catheters and other industrial applications. Our group has been giving emphasis to the characterization techniques for R ...

  18. Aplicação da técnica de fio quente na determinação das propriedades térmicas de polímeros fundidos Hot wire technique in the determination of thermal properties of melt polymers

    Directory of Open Access Journals (Sweden)

    Wilson N. dos Santos

    2005-11-01

    properties of a material that are needed for heat transfer calculations. Reliable thermal properties values are essential for polymers, both in steady and non-steady state situations. Nowadays, several different techniques for the determination of the thermal diffusivity and thermal conductivity may be found in the literature. In this work, the hot wire parallel technique is employed in the experimental determination of the thermal properties of polymers. Three semi-crystalline polymers (HDPE, LDPE and PP, and two amorphous polymers (PS and HIPS were selected for this work. Samples are prepared through the extrusion process starting from the powder or pellets of the solid polymer. A special mould of stainless steel in the shape of a rectangular parallelepiped provided with ceramic insulators between the hot wire, thermocouple and the mould is employed to store the melt extruded polymer whose thermal properties will be measured. Measurements are carried out from room temperature up to approximately 50 ºC above the melting point. Experimental results obtained are checked against data found in literature and those ones furnished by the manufacturers. A critical analysis of this method shows the advantages and disadvantages of this technique when compared with the laser flash technique.

  19. [Evaluation of the corrosion resistance of orthodontic wires by electrochemical measures and scanning electron microscopy (SEM)].

    Science.gov (United States)

    Zoghbi, André El; Klein, Lorena; Frateur, Isabelle

    2013-12-01

    The objective of this paper is to study the corrosion resistance of orthodontic wires made of different alloys (stainless steel, chrome-cobalt, nickel-titanium and β-titanium) and for the same alloy from different vendors (GAC(®), RMO(®), 3M(®) and ORMCO(®)). Different electrochemical techniques (corrosion potential monitoring as a function of immersion time, current-potential curves, electrochemical impedance spectroscopy (EIS)) were used. The wires' resistance to corrosion was measured and compared with the surface condition, assessed by scanning electron microscopy (SEM). Using the recorded data, a rating system based on the corrosion resistance of orthodontic wires was developed. The comparison of these data with the results of SEM shows that the surface chemical composition plays a primary role in the electrochemical behavior of the orthodontic wires and, unlike surface defects, is a key parameter for the corrosion resistance of the alloy. © EDP Sciences, SFODF, 2013.

  20. Development of CRID [Cerenkov Ring Imaging Detector] single electron wire detector

    International Nuclear Information System (INIS)

    Aston, D.; Bean, A.; Bienz, T.

    1989-02-01

    We describe the R and D effort to define the design parameters, method of construction and experimental results from the single electron wire detectors. These detectors will be used for particle identification using the Cerenkov Ring Imaging techniques in the SLD experiment at SLAC. We present measurements of pulse heights for several gases as a function of gas gain, charge division performance on a single electron signal using both 7 μm and 33 μm diameter carbon wires, photon feedback in TMAE laden gas, average pulse shape, and its comparison with the predicted shape and cross-talk. In addition, we present results of wire aging tests, and other tests associated with construction of this unusual type of wire chamber. 12 refs., 9 figs

  1. Guide Wire Entrapment during Central Venous Catheterization

    Directory of Open Access Journals (Sweden)

    Kyung Woo Kim

    2014-05-01

    Full Text Available We experienced a case of venous vessel wall entrapment between the introducer needle and the guide wire during an attempt to perform right internal jugular vein (IJV catheterization. The guide wire was introduced with no resistance but could not be withdrawn. We performed ultrasonography and C-arm fluoroscopy to confirm the entrapment location. We assumed the introducer needle penetrated the posterior vessel wall during the puncture and that only the guide wire entered the vein; an attempt to retract the wire pinched the vein wall between the needle tip and the guide wire. Careful examination with various diagnostic tools to determine the exact cause of entrapment is crucial for reducing catastrophic complications and achieving better outcomes during catheterization procedures.

  2. A comparative study of wireless and wired sensors networks for deficit irrigation management

    Science.gov (United States)

    Torres Sánchez, Roque; Domingo Miguel, Rafael; Valles, Fulgencio Soto; Perez-Pastor, Alejandro; Lopez Riquelme, Juan Antonio; Blanco Montoya, Victor

    2016-04-01

    In recent years, the including of sensors in the context of agricultural water management, has received an increasing interest for the establishment of irrigation strategies, such as regulated deficit irrigation (RDI). These strategies allow a significant improvement of crop water productivity (marketable yield / water applied), especially in woody orchards. The application of these deficit irrigation strategies, requires the monitoring of variables related to the orchard, with the purpose of achieving an efficiently irrigation management, since it is necessary to know the soil and plant water status to achieve the level of water deficit desired in each phenological stage. These parameters involve the measurements of soil and plant parameters, by using appropriate instrumentation devices. Traditional centralized instrumentation systems include soil matric potential, water content and LVDT sensors which information is stored by dataloggers with a wired connection to the sensors. Nowadays, these wired systems are being replaced by wireless ones due, mainly, to cost savings in wiring and labor. These technologies (WSNs) allow monitoring a wide variety of parameters in orchards with high density of sensors using discrete and autonomous nodes in the trees or soil places where it is necessary, without using wires. In this paper we present a trial in a cherry crop orchard, with different irrigation strategies where both a wireless and a wired system have been deployed with the aim of obtaining the best criteria on how to select the most suitable technology in future agronomic monitoring systems. The first stage of this study includes the deploying of nodes, wires, dataloggers and the installation of the sensors (same for both, wired and wireless systems). This stage was done during the first 15 weeks of the trial. Specifically, 40 MPS6 soil matric potential, 20 Enviroscan water content and 40 (LVDT and band) dendometers were installed in order to cover the experimental

  3. Biliary cannulation with a guide wire in pancreatic duct

    International Nuclear Information System (INIS)

    Castano, Rodrigo; Nunez, Edilberto; Sanin, Eugenio

    2009-01-01

    The angular stone in endoscopic cholangiography is an a traumatic and fast biliary cannulation, which results in the success of the procedure. In this series of 10 patients an easy technique is described that helps to cannulate a difficult biliary conduit. Methods. In cases of repeatedly cannulation of pancreatic duct and not selectively the biliary tract; it is suggested to leave the guide wire in the middle of the Wirsung duct and to retire the cannula or sphincterotome. The cannula or sphincterotome is reintroduced by the work channel next to the guide wire in the pancreatic conduit. With the guide in the pancreatic duct the cannula advances with better direction, stability and firmness of papilla. Results. This technique cases was used in 10 patients (6 hospitalized and 4 ambulatory) and was successful in all the patients, avoiding the necessity of the access to the biliary route by the technique of the pre cut. No complication was documented. Conclusions. Use of this technique can help to reduce the number of sphincterotomies by pre cuts, with increased risks of pancreatitis, bleeding and perforation. The proposed technique can help us in any difficult cannulation of the biliary route.

  4. Single wire drift chamber design

    Energy Technology Data Exchange (ETDEWEB)

    Krider, J.

    1987-03-30

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

  5. Centromeric banding pattern of mitotic chromosomes in Vigna vexillata

    African Journals Online (AJOL)

    Vigna vexillata chromosome characterization was carried out using the Leishman C- banding technique. The results showed that the chromosomes mostly exhibited bands at both the centromeric and telomeric regions. These bands will serve, as a valuable marker for the identification of the chromosomes. Chromosomes 2 ...

  6. Ultrasonographic examination of the radial and ulnar nerves after percutaneous cross-wiring of supracondylar humerus fractures in children: a prospective, randomized controlled study.

    Science.gov (United States)

    Altay, Mehmet Akif; Erturk, Cemil; Altay, Mehmet; Belhan, Oktay; Isikan, Ugur Erdem

    2011-09-01

    In this prospective study, we aimed to find out whether there is a change in the ultrasonographic features of the radial and ulnar nerves as well as clinical outcomes after traditional and lateral percutaneous cross-wiring of the supracondylar humerus fractures in children. Twenty-nine consecutive children with completely displaced Gartland type III supracondylar humerus fractures were treated with the traditional (group T) or lateral (group L) cross-wiring technique. Our findings showed that ultrasonographic features of the radial nerve were not changed in both groups but the ulnar nerve movement was reduced, and the diameter of major axis of the ulnar nerve during elbow flexion was larger (P=0.040) than in elbow extension in the traditional cross-wiring technique but not in the lateral cross-wiring technique. Lateral cross-wiring technique does not change the ultrasonographic features of the radial and ulnar nerves, and provides satisfactory results.

  7. Semiconductor Nano wires and Nano tubes: From Fundamentals to Diverse Applications

    International Nuclear Information System (INIS)

    Xiong, Q.; Grimes, C.A.; Zacharias, M.; Morral, A.F.; Hiruma, K.; Shen, G.

    2012-01-01

    written by K. Tateno et al. also reviews the vapor-liquid-solid (VLS-) grown core-multi shell Ga(In)P/GaAs/GaP nano wires on Si substrates and introduces an interesting phenomenon of formation of flat-top nano wires achieved by using small-sized Au particles in one growth procedure. The remaining papers illustrate the research on metal oxides semiconducting materials which are well known for wide band gap and transparent conducting properties

  8. Minimum quench energy measurement for superconducting wires

    International Nuclear Information System (INIS)

    Seo, K.; Morita, M.; Nakamura, S.; Yamada, T.; Jizo, Y.

    1996-01-01

    The authors have developed a new method of measuring minimum quench energy (MQE) of superconducting wire. There have been conventional methods using heating wires, whose diameters are ∼0.1mm and are glued by epoxy resin. When they induce a pulse heat to superconducting wires, a duration of the pulse must be several hundreds micro seconds to demonstrate actual disturbances (for instance wire motion) in a superconducting magnet. In spite of this fact, thermal diffusion time constants of the conventional heaters are larger than the duration of the actual disturbance, because of these electrical insulator of the heating wire and the epoxy bind. Therefore, this kind of heater is not able to demonstrate the actual disturbance. To solve this problem, they have proposed a new constitution of a heater. In the method, heat generation is introduced in high resistive layer on a surface of a superconducting wire. The high resistive layer is consist of carbon paste. The thickness of the carbon paste layer is ∼20microm, thus a time constant of this heater is expected to be small enough to demonstrate the actual disturbance. Adopting the new method to the MQE measurement, they successfully evaluate MQE of superconducting wires with high precision. Several results are introduced in this paper

  9. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  10. Wide Band to ''Double Band'' upgrade

    International Nuclear Information System (INIS)

    Kasper, P.; Currier, R.; Garbincius, P.; Butler, J.

    1988-06-01

    The Wide Band beam currently uses electrons obtained from secondary photon conversions to produce the photon beam incident on the experimental targets. By transporting the positrons produced in these conversions as well as the electrons it is possible to almost double the number of photons delivered to the experiments per primary beam proton. 11 figs

  11. Mechanical behaviour of copper 15% volume niobium microcomposite wires

    Directory of Open Access Journals (Sweden)

    Marcello Filgueira

    2001-01-01

    Full Text Available Cu-Nb microcomposites are attractive in magnet pulsed field technology applications due to their anomalous mechanism of mechanical strength and high electrical conductivity. In this sense, recently it was conceived the use of Cu 15% vol. Nb wires to operate as a high tensile strength cable for a diamond cutting tool (diamond wires for marble and granite slabbing. The multifilamentary Cu 15% vol. Nb composite was obtained using a new processing route, starting with niobium bars bundled into copper tubes, without arc melting. Cold working techniques, such as swaging and wire drawing, combined with heat treatments such as sintering and annealing, and tube restacking were employed. The tensile property of the composite was measured as a function of the niobium filaments dimensions and morphology into the copper matrix, in the several processing steps. An ultimate tensile strength (UTS of 960 MPa was obtained for an areal reduction (R = Ao/A, with Ao-initial cross section area, and A-final cross section area of 4x10(8 X, in which the niobium filaments reached thickness less than 20 nm. The anomalous mechanical strength increase is attributed to the fact that the niobium filaments acts as a barrier to copper dislocations.

  12. Transoral screw and wire fixation for unstable anterior ½ atlas fracture

    Directory of Open Access Journals (Sweden)

    Semih Keskil

    2017-01-01

    Conclusions: Internal immobilization by this screw and wire osteosynthesis technique protects the mobility of the atlanto-occipital and atlantoaxial joints. The main advantage is that neither the twisted wires inserted under the anterior lamina, nor the laterally placed screw heads interfere with midline wound closure; unlike the plate/cage and rod systems used together with anterior screws. A computer navigation system with intraoperative 3D imaging facilities will be of benefit for safe placement of the screw, however we preferred a free-hand technique, as the starting point was at the fracture line along the trajectory of the routinely accessible anterior lamina.

  13. Resonant tunneling of electrons in quantum wires

    International Nuclear Information System (INIS)

    Krive, I.V.; Shekhter, R.I.; Jonson, M.; Krive, I.V.

    2010-01-01

    We considered resonant electron tunneling in various nanostructures including single wall carbon nanotubes, molecular transistors and quantum wires formed in two-dimensional electron gas. The review starts with a textbook description of resonant tunneling of noninteracting electrons through a double-barrier structure. The effects of electron-electron interaction in sequential and resonant electron tunneling are studied by using Luttinger liquid model of electron transport in quantum wires. The experimental aspects of the problem (fabrication of quantum wires and transport measurements) are also considered. The influence of vibrational and electromechanical effects on resonant electron tunneling in molecular transistors is discussed.

  14. Problems associated with iridium-192 wire implants

    International Nuclear Information System (INIS)

    Arnott, S.J.; Law, J.; Ash, D.; Flynn, A.; Paine, C.H.; Durrant, K.R.; Barber, C.D.; Dixon-Brown, A.

    1985-01-01

    Three incidents are reported, from different radiotherapy centres, in which an implanted iridium-192 wire remained in the tissues of a patient after withdrawal of the plastic tubing in which it was contained. In each case the instrument used to cut the wire had probably formed a hook on the end of the wire which caused it to catch in the tissues. Detailed recommendations are made for avoiding such incidents in the future, the most important of which is that the patient should be effectively monitored after the supposed removal of all radioactive sources. (author)

  15. Investigation of wire motion in superconducting magnets

    International Nuclear Information System (INIS)

    Ogitsu, T.; Tsuchiya, K.; Devred, A.

    1990-09-01

    The large Lorentz forces occuring during the excitation of superconducting magnets can provoke sudden motions of wire, which eventually release enough energy to trigger a quench. These wire motions are accompanied by two electromagnetic effects: an induced emf along the moved wire, and a local change in flux caused by the minute dislocation of current. Both effects cause spikes in the coil voltage. Voltage data recorded during the excitation of a superconducting quadrupole magnet which early exhibit such events are here reported. Interpretations of the voltage spikes in terms of energy release are also presented, leading to insights on the spectrum of the disturbances which occur in real magnets. 15 refs

  16. Retention of riveted aluminum leg bands by wild turkeys

    Science.gov (United States)

    Diefenbach, Duane R.; Vreeland, Wendy C.; Casalena, Mary Jo; Schiavone, Michael V.

    2016-01-01

    In order for mark–recapture models to provide unbiased estimates of population parameters, it is critical that uniquely identifying tags or marks are not lost. We double-banded male and female wild turkeys with aluminum rivet bands and estimated the probability that a bird would be recovered with both bands aluminum bands, we believe they are an effective marking technique for wild turkeys and, for most studies, will minimize any concern about the assumption that marks are not lost.

  17. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    Directory of Open Access Journals (Sweden)

    Ahmad

    2016-06-01

    Full Text Available Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO. Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS orthodontic wires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnO nanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electron microscope evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wires and brackets in four groups: group ZZ (coated wire and bracket, group OO (uncoated wire and bracket, group ZO (coated wire and uncoated bracket and group OZ (uncoated wire and coated bracket. Kolmogorov-Smirnov, Mann-Whitney and Kruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N was the highest (P <0.05, and OZ (2.18±0.5 N had the lowest amount of friction (P <0.05 among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively. Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique, and wire coating combined with bracket coating is not recommended due to its effect on friction.

  18. Band - Weg interactie

    NARCIS (Netherlands)

    de Boer, Andries; ter Huerne, Henderikus L.; Noordermeer, Jacobus W.M.; Schipper, Dirk J.; prof.dr.ir. Molenaar, A.A.A.

    2008-01-01

    De huidige infrastructuur van wegen waarover men zich snel en comfortabel kan verplaatsen is niet meer weg te denken uit onze maatschappij. Twee “componenten” die hierbij een belangrijke rol spelen zijn het wegdek en de band. Het contact tussen band en wegdek is mede bepalend voor de veiligheid. De

  19. Photonic band structure computations.

    Science.gov (United States)

    Hermann, D; Frank, M; Busch, K; Wolfle, P

    2001-01-29

    We introduce a novel algorithm for band structure computations based on multigrid methods. In addition, we demonstrate how the results of these band structure calculations may be used to compute group velocities and effective photon masses. The results are of direct relevance to studies of pulse propagation in such materials.

  20. Wired Widgets: Agile Visualization for Space Situational Awareness

    Science.gov (United States)

    Gerschefske, K.; Witmer, J.

    2012-09-01

    Continued advancement in sensors and analysis techniques have resulted in a wealth of Space Situational Awareness (SSA) data, made available via tools and Service Oriented Architectures (SOA) such as those in the Joint Space Operations Center Mission Systems (JMS) environment. Current visualization software cannot quickly adapt to rapidly changing missions and data, preventing operators and analysts from performing their jobs effectively. The value of this wealth of SSA data is not fully realized, as the operators' existing software is not built with the flexibility to consume new or changing sources of data or to rapidly customize their visualization as the mission evolves. While tools like the JMS user-defined operational picture (UDOP) have begun to fill this gap, this paper presents a further evolution, leveraging Web 2.0 technologies for maximum agility. We demonstrate a flexible Web widget framework with inter-widget data sharing, publish-subscribe eventing, and an API providing the basis for consumption of new data sources and adaptable visualization. Wired Widgets offers cross-portal widgets along with a widget communication framework and development toolkit for rapid new widget development, giving operators the ability to answer relevant questions as the mission evolves. Wired Widgets has been applied in a number of dynamic mission domains including disaster response, combat operations, and noncombatant evacuation scenarios. The variety of applications demonstrate that Wired Widgets provides a flexible, data driven solution for visualization in changing environments. In this paper, we show how, deployed in the Ozone Widget Framework portal environment, Wired Widgets can provide an agile, web-based visualization to support the SSA mission. Furthermore, we discuss how the tenets of agile visualization can generally be applied to the SSA problem space to provide operators flexibility, potentially informing future acquisition and system development.

  1. Ureteroscopy during pregnancy with follow-the-wire technique ...

    African Journals Online (AJOL)

    A stent with string was placed for 5-7 days. Results: Ureteroscopy was successfully performed in all patients without ureteral dilation. Stones (6-9 mm in diameter) were detected in 18 patients. Eleven patients had distal stones while 7 had proximal stones. Fluoroscopy was not required. There were no complications related ...

  2. Electrochemically deposited BiTe-based nano wires for thermoelectric applications

    International Nuclear Information System (INIS)

    Inn-Khuan, N.; Kuan-Ying, K.; Che Zuraini Che Abdul Rahman; Nur Ubaidah Saidin; Suhaila Hani Ilias; Thye-Foo, C.

    2013-01-01

    Full-text: Nano structured materials systems such as thin-films and nano wires (NWs) are promising for thermoelectric power generation and refrigeration compared to traditional counterparts in bulk, due to their enhanced thermoelectric figures-of-merit. BiTe and its derivative compounds, in particular, are well-known for their near-room temperature thermoelectric performance. In this work, both the binary and ternary BiTe-based nano wires namely, BiTe and BiSbTe, were synthesized using template-assisted electrodeposition. Diameters of the nano wires were controlled by the pore sizes of the anodised alumina (AAO) templates used. Systematic study on the compositional change as a function of applied potential was carried out via Linear Sweep Voltametry (LSV). Chemical compositions of the nano wires were studied using Energy Dispersive X-ray Spectrometry (EDXS) and their microstructures evaluated using diffraction and imaging techniques. Results from chemical analysis on the nano wires indicated that while the Sb content in BiSbTe nano wires increased with more negative deposition potentials, the formation of Te 0 and Bi 2 Te 3 were favorable at more positive potentials. (author)

  3. Interlot variations of transition temperature range and force delivery in copper-nickel-titanium orthodontic wires.

    Science.gov (United States)

    Pompei-Reynolds, Renée C; Kanavakis, Georgios

    2014-08-01

    The manufacturing process for copper-nickel-titanium archwires is technique sensitive. The primary aim of this investigation was to examine the interlot consistency of the mechanical properties of copper-nickel-titanium wires from 2 manufacturers. Wires of 2 sizes (0.016 and 0.016 × 0.022 in) and 3 advertised austenite finish temperatures (27°C, 35°C, and 40°C) from 2 manufacturers were tested for transition temperature ranges and force delivery using differential scanning calorimetry and the 3-point bend test, respectively. Variations of these properties were analyzed for statistical significance by calculating the F statistic for equality of variances for transition temperature and force delivery in each group of wires. All statistical analyses were performed at the 0.05 level of significance. Statistically significant interlot variations in austenite finish were found for the 0.016 in/27°C (P = 0.041) and 0.016 × 0.022 in/35°C (P = 0.048) wire categories, and in austenite start for the 0.016 × 0.022 in/35°C wire category (P = 0.01). In addition, significant variations in force delivery were found between the 2 manufacturers for the 0.016 in/27°C (P = 0.002), 0.016 in/35.0°C (P = 0.049), and 0.016 × 0.022 in/35°C (P = 0.031) wires. Orthodontic wires of the same material, dimension, and manufacturer but from different production lots do not always have similar mechanical properties. Clinicians should be aware that copper-nickel-titanium wires might not always deliver the expected force, even when they come from the same manufacturer, because of interlot variations in the performance of the material. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  4. Differences in the Microbial Colonization Among Arch Wire Types, Gauges and Cross Sections

    Directory of Open Access Journals (Sweden)

    Reem A. Rafeeq

    2018-02-01

    Full Text Available Background: The presence of orthodontic materials in the oral cavity represent a unique surface that can interact with bacteria, leading to pathogenic plaque formation and subsequent enamel demineralization, Streptococcus mutans play an important role in the initiation and progression of dental caries and they are considered the primary cause of bacteriological caries. The objective of this study was to investigate the effect of multiple factors including the type of arch wire, salivary coating, cross section, and wire thickness on the levels of mutans streptococci adherence. Materials and Methods: Two types of arch wire stainless steel and nickel titanium were selected using the following criteria: round and rectangular with gauges 0.014, 0.018, 0.016 × 0.022 and 0.019 × 0.0 25 inches which were subdivided into eight groups. Bacterial adhesion was quantified by a microbial culture technique and the number of adhesive bacteria were analyzed and counted after growth in culture for each group with and without saliva coating at 15 and 60 minutes. Detection of mutans streptococci by saliva-check Mutans test. Results: There was a significant difference between arch wire types in each time interval and the highest bacterial adhesion on the NiTi arch wires with rectangular cross section in the absence of saliva with extended incubation time. Conclusions: The adherence of mutans streptococci in saliva coated wires seems to be low. At increased incubation time, rectangular cross section arch wire showed an increased number of adhering bacteria with less effect on different gauges of the arch wire.

  5. 47 CFR 76.802 - Disposition of cable home wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  6. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  7. 47 CFR 32.2321 - Customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Customer premises wiring. 32.2321 Section 32... Customer premises wiring. (a) This account shall include all amounts transferred from the former Account 232, Station Connections, inside wiring subclass. (b) Embedded Customer Premises Wiring is that...

  8. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...

  9. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  10. Beam Profiling through Wire Chambing Tracking

    CERN Document Server

    Nash, W

    2013-01-01

    This note describes the calibration of the Delay Wire Chambers (DWCs) used during test runs of CALICE’s Tungsten Digital Hadron Calorimeter (W-DHCAL) prototype in CERN’s SPS beam line (10 – 300 GeV).

  11. Copyright and Wire Broadcasting Under Belgian Law

    Science.gov (United States)

    Namurois, Albert

    1975-01-01

    A discussion of a case whereby substantial damages, if not criminal proceedings, will sanction, according to circumstances, both television organizations and those who in certain conditions distribute their programs by wire or communicate them to the public. (Author/HB)

  12. Highly stretchable wrinkled gold thin film wires.

    Science.gov (United States)

    Kim, Joshua; Park, Sun-Jun; Nguyen, Thao; Chu, Michael; Pegan, Jonathan D; Khine, Michelle

    2016-02-08

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  13. Tensosensitivity of the Hot-Wire Probe

    National Research Council Canada - National Science Library

    Pak, A

    2002-01-01

    ...., on the anemometer type. In a constant current anemometer, it is possible to measure and separate out the noise moving to the electric circuit of the anemometer, it is not the case with hot-wire anemometers of other types...

  14. Molecular wires, switches and memories

    Science.gov (United States)

    Chen, Jia

    Molecular electronics, an emerging field, makes it possible to build individual molecules capable of performing functions identical or analogous to present- day conductors, switches, or memories. These individual molecules, with a nano-meter scale characteristic length, can be designed and chemically synthesized with specific atoms, geometries and charge distribution. This thesis focuses on the design, and measurements of molecular wires, and related strategically engineered structures-molecular switches and memories. The experimental system relies on a thermodynamically driven self-assembling process to attach molecules onto substrate surfaces without intervention from outside. The following topics will be discussed: directed nanoscale manipulation of self-assembled molecules using scanning tunneling microscope; investigation on through-bond transport of nanoscale symmetric metal/conjugated self- assembled monolayers (SAM)/metal junctions, where non- Ohmic thermionic emission was observed to be the dominant process, with isocyanide-Pd contacts showing the lowest thermionic barrier of 0.22 eV; the first realization of robust and large reversible switching behavior in an electronic device that utilizes molecules containing redox centers as the active component, exhibiting negative differential resistance (NDR) and large on-off peak-to-valley ratio (PVR); observation of erasable storage of higher conductivity states in these redox- center containing molecular devices, and demonstration of a two-terminal electronically programmable and erasable molecular memory cell with long bit retention time.

  15. Data transmission techniques for short-range optical fiber and wireless communication links

    DEFF Research Database (Denmark)

    Pham, Tien Thang

    -speed optical/wireless integration and advanced modulation formats for intensity modulation with direct detection (IM/DD) optical systems. Regarding optical/wireless integration, this thesis focuses on integration of broadband ultra-wide band (UWB) and 60-GHz band wireless systems into optical fiber access...... signals into a unified optical fiber platform. Additionally, half-cycle QAM modulation has prospects to increase SE and bit rates in high-speed short-range optical communication systems.......The research work described in this thesis is devoted to experimental investigation of techniques for cost-effective high-speed optical communications supporting both wired and wireless services. The main contributions of this thesis have expanded the state-of-the-art in two main areas: high...

  16. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

    Science.gov (United States)

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-08-09

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in² and 0.019 × 0.025 in² (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm ( p 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire ( p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

  17. Note: Improved wire-wound heater.

    Science.gov (United States)

    Steinmann, Ricardo G; Vitoux, Hugo

    2015-01-01

    The authors have measured, at cryogenic temperature, the upper limit of the heat transfer in different configurations of a wire-wound heater. We found that the heat transferred has an upper limit of about 15 W/cm(2) and is dependent on the diameter of the wire. In this paper, we present three ways of increasing the heat transferred by this type of heater and its application in different continuous flow cryostats.

  18. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  19. Novel use of the "buddy"wire.

    LENUS (Irish Health Repository)

    O'Hare, A

    2008-12-29

    Summary: During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.

  20. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  1. COBRA-IV wire wrap data comparisons

    International Nuclear Information System (INIS)

    Donovan, T.E.; George, T.L.; Wheeler, C.L.

    1979-02-01

    Thermal hydraulic analyses of hexagonally packed wire-wrapped fuel assemblies are complicated by the induced crossflow between adjacent subchannels. The COBRA-IV computer code simultaneously solves the hydrodynamics and thermodynamics of fuel assemblies. The modifications and the results are presented which are predicted by the COBRA-IV calculation. Comparisons are made with data measured in five experimental models of a wire-wrapped fuel assembly

  2. Reliable Acquisition of RAM Dumps from Intel-Based Apple Mac Computers over FireWire

    Science.gov (United States)

    Gladyshev, Pavel; Almansoori, Afrah

    RAM content acquisition is an important step in live forensic analysis of computer systems. FireWire offers an attractive way to acquire RAM content of Apple Mac computers equipped with a FireWire connection. However, the existing techniques for doing so require substantial knowledge of the target computer configuration and cannot be used reliably on a previously unknown computer in a crime scene. This paper proposes a novel method for acquiring RAM content of Apple Mac computers over FireWire, which automatically discovers necessary information about the target computer and can be used in the crime scene setting. As an application of the developed method, the techniques for recovery of AOL Instant Messenger (AIM) conversation fragments from RAM dumps are also discussed in this paper.

  3. Gold-wire artifacts on diagnostic radiographs: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Keestra, Johan Anton Jochum; Jacobs, Reinhilde; Quirynen, Marc [Dept. of Oral Health Sciences, KU Leuven and Dentistry, University Hospitals, KU Leuven, Leuven (Belgium)

    2014-03-15

    This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

  4. Gold-wire artifacts on diagnostic radiographs: A case report

    International Nuclear Information System (INIS)

    Keestra, Johan Anton Jochum; Jacobs, Reinhilde; Quirynen, Marc

    2014-01-01

    This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

  5. Subchannel Analysis of Wire Wrapped SCWR Assembly

    Directory of Open Access Journals (Sweden)

    Jianqiang Shan

    2014-01-01

    Full Text Available Application of wire wrap spacers in SCWR can reduce pressure drop and obtain better mixing capability. As a consequence, the required coolant pumping power is decreased and the coolant temperature profile inside the fuel bundle is flattened which will obviously decrease the peak cladding temperature. The distributed resistance model for wire wrap was developed and implemented in ATHAS subchannel analysis code. The HPLWR wire wrapped assembly was analyzed. The results show that: (1 the assembly with wire wrap can obtain a more uniform coolant temperature profile than the grid spaced assembly, which will result in a lower peak cladding temperature; (2 the pressure drop in a wire wrapped assembly is less than that in a grid spaced assembly, which can reduce the operating power of pump effectively; (3 the wire wrap pitch has significant effect on the flow in the assembly. Smaller Hwire/Drod will result in stronger cross flow a more uniform coolant temperature profile, and also a higher pressure drop.

  6. Superconducting wires and methods of making thereof

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xingchen; Sumption, Michael D.; Peng, Xuan

    2018-03-13

    Disclosed herein are superconducting wires. The superconducting wires can comprise a metallic matrix and at least one continuous subelement embedded in the matrix. Each subelement can comprise a non-superconducting core, a superconducting layer coaxially disposed around the non-superconducting core, and a barrier layer coaxially disposed around the superconducting layer. The superconducting layer can comprise a plurality of Nb.sub.3Sn grains stabilized by metal oxide particulates disposed therein. The Nb.sub.3Sn grains can have an average grain size of from 5 nm to 90 nm (for example, from 15 nm to 30 nm). The superconducting wire can have a high-field critical current density (J.sub.c) of at least 5,000 A/mm.sup.2 at a temperature of 4.2 K in a magnetic field of 12 T. Also described are superconducting wire precursors that can be heat treated to prepare superconducting wires, as well as methods of making superconducting wires.

  7. Si Wire-Array Solar Cells

    Science.gov (United States)

    Boettcher, Shannon

    2010-03-01

    Micron-scale Si wire arrays are three-dimensional photovoltaic absorbers that enable orthogonalization of light absorption and carrier collection and hence allow for the utilization of relatively impure Si in efficient solar cell designs. The wire arrays are grown by a vapor-liquid-solid-catalyzed process on a crystalline (111) Si wafer lithographically patterned with an array of metal catalyst particles. Following growth, such arrays can be embedded in polymethyldisiloxane (PDMS) and then peeled from the template growth substrate. The result is an unusual photovoltaic material: a flexible, bendable, wafer-thickness crystalline Si absorber. In this paper I will describe: 1. the growth of high-quality Si wires with controllable doping and the evaluation of their photovoltaic energy-conversion performance using a test electrolyte that forms a rectifying conformal semiconductor-liquid contact 2. the observation of enhanced absorption in wire arrays exceeding the conventional light trapping limits for planar Si cells of equivalent material thickness and 3. single-wire and large-area solid-state Si wire-array solar cell results obtained to date with directions for future cell designs based on optical and device physics. In collaboration with Michael Kelzenberg, Morgan Putnam, Joshua Spurgeon, Daniel Turner-Evans, Emily Warren, Nathan Lewis, and Harry Atwater, California Institute of Technology.

  8. Needleless electrospinning with twisted wire spinneret

    International Nuclear Information System (INIS)

    Holopainen, Jani; Penttinen, Toni; Santala, Eero; Ritala, Mikko

    2015-01-01

    A needleless electrospinning setup named ‘Needleless Twisted Wire Electrospinning’ was developed. The polymer solution is electrospun from the surface of a twisted wire set to a high voltage and collected on a cylindrical collector around the wire. Multiple Taylor cones are simultaneously self-formed on the downward flowing solution. The system is robust and simple with no moving parts aside from the syringe pump used to transport the solution to the top of the wire. The structure and process parameters of the setup and the results on the preparation of polyvinyl pyrrolidone (PVP), hydroxyapatite (HA) and bioglass fibers with the setup are presented. PVP fiber sheets with areas of 40 × 120 cm 2 and masses up to 1.15 g were prepared. High production rates of 5.23 g h −1 and 1.40 g h −1 were achieved for PVP and HA respectively. The major limiting factor of the setup is drying of the polymer solution on the wire during the electrospinning process which will eventually force to interrupt the process for cleaning of the wire. Possible solutions to this problem and other ways to develop the setup are discussed. The presented system provides a simple way to increase the production rate and area of fiber sheet as compared with the conventional needle electrospinning. (paper)

  9. Electron beam welding using fusion and cold wire fill

    International Nuclear Information System (INIS)

    Kuncz, F.F.

    1977-01-01

    A straight-fusion (self-filler) welding technique generally poses no problem for electron beam welding. However, where control of penetration is a critical item and burn-through cannot be tolerated, this technique may not be satisfactory. To assure against beam-spike burn-through on a 1/4-inch deep weld joint, a low-power root-fusion pass, supplemented by numerous filler passes, was selected. However, this technique proved to have numerous problems. Voiding and porosity showed frequently in the first applications of this cold-wire filler process. Taper-out cratering, bead-edge undercutting, and spatter were also problems. These imperfections, however, were overcome. Employment of a circle generator provided the necessary heating of the joint walls to eliminate voids. The moving beam spot also provided a stirring action, lessening porosity. Taper-out cratering was eliminated by adjusting the timing of the current cutoff and wire-feed cutoff. Undercutting, bead height, and spatter were controlled by beam defocus

  10. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Science.gov (United States)

    2010-09-30

    ... COMMISSION In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire... importation, or the sale within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent Nos...

  11. Fifth metacarpal neck fracture fixation: Locking plate versus K-wire?

    Science.gov (United States)

    Facca, S; Ramdhian, R; Pelissier, A; Diaconu, M; Liverneaux, P

    2010-09-01

    Neck fractures of the fifth metacarpal bone can leave sequelae. Surgery is indicated when the displacement of the head in flexion exceeds 45° and/or rotation is impaired. Among available techniques, non-locking mini-plates have the most drawbacks; recently developed locking plates may, however, challenge the preference for K-wires. The present study compared results between locking plates and intramedullary K-wires. The series comprised 38 fifth metacarpal fractures: 18 were managed by locking plate (group I) and 20 by intramedullary K-wire (group II). Results were analyzed on subjective and objective criteria (pain, DASH, strength, mobility, time off work, radiology). No significant differences were found for pain, DASH, strength, time off work or head displacement at last follow-up. Active mobility, however, was significantly greater in the K-wire group, with mean relative metacarpophalangeal flexion 59% of healthy-side values in group I vs. 98% in group II, and mean relative extension 89% in group I vs. 99% in group II. Group I showed six complications (three cases of stiffness, one of head necrosis, two of delayed consolidation) vs. seven in group II (three cases of wire migration, three of neurologic lesion, one of esthetic blemish). Locking plates with immediate mobilization paradoxically provided poorer mobility at end of follow-up than intramedullary K-wire with 6 weeks' immobilization. The extra cost of locking plates was thus not justified by results. Intramedullary K-wire nailing remains the reference technique for the management of displaced fracture of the fifth metacarpal neck. Level IV continuous prospective comparative study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  12. Band parameters of phosphorene

    DEFF Research Database (Denmark)

    Lew Yan Voon, L. C.; Wang, J.; Zhang, Y.

    2015-01-01

    Phosphorene is a two-dimensional nanomaterial with a direct band-gap at the Brillouin zone center. In this paper, we present a recently derived effective-mass theory of the band structure in the presence of strain and electric field, based upon group theory. Band parameters for this theory...... are computed using a first-principles theory based upon the generalized-gradient approximation to the density-functional theory. These parameters and Hamiltonian will be useful for modeling physical properties of phosphorene....

  13. Empolder and application of LiveWire program

    International Nuclear Information System (INIS)

    Zhang Bo; Li Jing; Wang Xiaoming

    2007-01-01

    LiveWire is a specific module of Netscape Web server to actualize CGI function; through LiveWire application program one can create dynamic web page on web site. This article introduces how to write LiveWire application code, have to compile, debug and manage LiveWire application programs, and how to apply LiveWire application program on Netscape Web server to create a dynamic web page. (authors)

  14. Wiring design for the control of electromagnetic interference (EMI)

    Science.gov (United States)

    Kopasakis, George

    1995-01-01

    Wiring design is only one important aspect of EMI control. Other important areas for EMI are: circuit design, filtering, grounding, bonding, shielding, lighting, electrostatic discharge (ESD), transient suppression, and electromagnetic pulse (EMP). Topics covered include: wire magnetic field emissions at low frequencies; wire radiated magnetic field emissions at frequencies; wire design guidelines for EMI control; wire design guidelines for EMI control; high frequency emissions from cables; and pulse frequency spectra.

  15. Analysis of ultra-relativistic charged particle beam and stretched wire measurement interactions with cylindrically symmetric structures

    International Nuclear Information System (INIS)

    Deibele, C.E.

    1996-01-01

    The beam impedance and wakefield are quantities which describe the stability of charged particles in their trajectory within an accelerator. The stretched wire measurement technique is a method which estimates the beam impedance and wakefield. Definitions for the beam impedance, the wakefield, and the stretched wire measurement are presented. A pillbox resonator with circular beampipes is studied for its relatively simple profile and mode structure. Theoretical predictions and measurement data are presented for the interaction of various charged particle beams and center conductor geometries between the cavity and beampipe. Time domain predictions for the stretched wire measurement and wakefield are presented and are shown to be a linear interaction

  16. Comparative biomechanic study of flexor tendon repair using FiberWire.

    Science.gov (United States)

    Waitayawinyu, Thanapong; Martineau, Paul A; Luria, Shai; Hanel, Douglas P; Trumble, Thomas E

    2008-01-01

    FiberWire, an increasingly popular suture material, allows for strong flexor tendon repair that may allow early mobilization. This study was designed to evaluate the mechanical characteristics of FiberWire for flexor tendon repair and to identify the most effective repair technique using this material. Forty-nine human cadaver flexor tendons were randomized and tested biomechanically using one of the following techniques of flexor tendon repair performed with 3-0 FiberWire: (1) modified Kessler, (2) modified Pennington, (3) 2-strand multiple grasping, (4) 2-strand multiple locking, (5) 2-strand double cross-locks, (6) Massachusetts General Hospital, and (7) 4-strand locked cruciate. The ultimate tensile strength, 2-mm gap resistance, and failure mode of the repairs were evaluated. Knot unraveling was the most common failure mode of FiberWire repair in 4 of the 7 techniques. Four-strand repairs and locking repairs provided significantly more strength than 2-strand repairs and grasping repairs. Multiple grasping and multiple locking repairs with 2 knots were significantly weaker than single grasping and locking repairs with a single knot. Four-strand locked cruciate repairs were significantly stronger than the other techniques (mean ultimate tensile strength 107 N, 2-mm gap force 96 N). Two-strand double cross-locks repairs were stronger than the other 2-strand repairs (mean ultimate tensile strength 69 N, 2-mm gap force 53 N). The strength of the FiberWire repairs increased with locking repair and with increased number of strands but was not influenced by increased number of locking and grasping stitches. Four-strand locked cruciate and 2-strand double cross-locks provided the greatest strength and likely are appropriate for future clinical use in, respectively, 4-strand and 2-strand repairs. However, the poor knot-holding characteristics of FiberWire with the need of a greater number of knot throws may be of concern for surgeons using this product for flexor tendon

  17. Preparation and Evaluation of a Polyimide-Coated Ultrafine Gilt Molybdenum Wire and Its Knitted Mesh Used for Electromagnetic Reflectors

    Directory of Open Access Journals (Sweden)

    Huiqi Shao

    2017-12-01

    Full Text Available In this work, polyimide (PI was coated onto an ultrafine gilt molybdenum wire in order to protect the gilt surface and prepare an electrically stable wire mesh material which can be widely used in space. The surface of the PI-coated gilt molybdenum wires was characterized using FTIR, SEM, and EDS. Factors such as temperature stability of the PI coating, mechanical properties of the PI-coated gilt molybdenum wires, contact resistance stability, and electromagnetic microwave reflectivity of the their knitted meshes were also investigated. The results indicate that the PI coating conformed uniformly to the surface of the gilt molybdenum wires. The prepared PI coating exhibited excellent temperature stability in the −196 to 300 °C range and could efficiently protect the gilt surface and improve the stability of contact resistance, while the reflection of its wire meshes showed only a slight decrease of 1.4% with the PI coating thickness of 3 μm for electromagnetic microwaves in the S band.

  18. Tri-Band PCB Antenna for Wireless Sensor Network Transceivers in Home Automation Applications

    DEFF Research Database (Denmark)

    Rohde, John; Toftegaard, Thomas Skjødeberg

    2012-01-01

    A novel tri-band antenna design for wireless sensor network devices in home automation applications is proposed. The design is based on a combination of a conventional monopole wire antenna and discrete distributed load impedances. The load impedances are employed to ensure the degrees of freedom...

  19. Nature of sub-band gap luminescent eigenmodes in a ZnO nanowire

    NARCIS (Netherlands)

    Rühle, S.|info:eu-repo/dai/nl/31407659X; van Vugt, L.K.|info:eu-repo/dai/nl/338773800; Li, H.-Y.; Keizer, N.A.; Kuipers, L.; Vanmaekelbergh, D.A.M.|info:eu-repo/dai/nl/304829137

    2008-01-01

    The emission spectrum of individual high-quality ZnO nanowires consists of a series of Fabry-Pérot-like eigenmodes that extend far below the band gap of ZnO. Spatially resolved luminescence spectroscopy shows that light is emitted predominantly at both wire ends, with identical spectra reflecting

  20. Development of Nb3Sn multi-filamentary wires superior in mass productivity

    International Nuclear Information System (INIS)

    Nakagawa, Kazuhiko; Ohata, Katsumi; Miyashita, Katsumi; Nakada, Yasushi

    2015-01-01

    We have developed superconducting wire about bronze route Nb 3 Sn and internal tin processed Nb 3 Sn. SH Copper Products Ltd. manufactures bronze route Nb 3 Sn superconducting strands for ITER-TF coils under a contract with the Japan Atomic Energy Agency (JAEA). The Nb 3 Sn strands which are composed of Nb-1 wt%Ta filaments and Cu-15.5 wt%-0.3 wt%Ti bronze have good workability and high performance. More than 850 A/mm 2 of non Cu J c at 12 T can be stably obtained using two-stage heat treatment technique. The internal-tin technique is an excellent method for fabricating Nb 3 Sn superconducting wire with a high critical current density. We have developed a new type of internal-tin Nb 3 Sn wire in which the multi-filamentary wire is fabricated by combining mono-filamentary Nb elements and mono-filamentary Sn elements. The simple fabrication process will enable the fabrication cost of the wires to be reduced. (author)

  1. Release of nickel and chromium ions from orthodontic wires following the use of teeth whitening mouthwashes

    Directory of Open Access Journals (Sweden)

    AmirHossein Mirhashemi

    2018-02-01

    Full Text Available Abstract Background Corrosion resistance is an important requirement for orthodontic appliances. Nickel and chromium may be released from orthodontic wires and can cause allergic reactions and cytotoxicity when patients use various mouthwashes to whiten their teeth. Our study aimed to assess the release of nickel and chromium ions from nickel titanium (NiTi and stainless steel (SS orthodontic wires following the use of four common mouthwashes available on the market. Methods This in vitro, experimental study was conducted on 120 orthodontic appliances for one maxillary quadrant including five brackets, one band and half of the required length of SS, and NiTi wires. The samples were immersed in Oral B, Oral B 3D White Luxe, Listerine, and Listerine Advance White for 1, 6, 24, and 168 h. The samples immersed in distilled water served as the control group. Atomic absorption spectroscopy served to quantify the amount of released ions. Results Nickel ions were released from both wires at all time-points; the highest amount was in Listerine and the lowest in Oral B mouthwashes. The remaining two solutions were in-between this range. The process of release of chromium from the SS wire was the same as that of nickel. However, the release trend in NiTi wires was not uniform. Conclusions Listerine caused the highest release of ions. Listerine Advance White, Oral B 3D White Luxe, and distilled water were the same in terms of ion release. Oral B showed the lowest amount of ion release.

  2. Laparoscopic gastric banding

    Science.gov (United States)

    ... eat by making you feel full after eating small amounts of food. After surgery, your doctor can adjust the band ... You will feel full after eating just a small amount of food. The food in the small upper pouch will ...

  3. Decay of superdeformed bands

    International Nuclear Information System (INIS)

    Carpenter, M.P.; Khoo, T.L.; Lauritsen, T.

    1995-01-01

    One of the major challenges in the study of superdeformation is to directly connect the large number of superdeformed bands now known to the yrast states. In this way, excitation energies, spins and parities can be assigned to the levels in the second well which is essential to establish the collective and single-particle components of these bands. This paper will review some of the progress which has been made to understand the decay of superdeformed bands using the new arrays including the measurement of the total decay spectrum and the establishment of direct one-step decays from the superdeformed band to the yrast line in 194 Hg. 42 refs., 5 figs

  4. HYBASE - HYperspectral BAnd SElection tool

    NARCIS (Netherlands)

    Schwering, P.B.W.; Bekman, H.H.P.T.; Seijen, H.H. van

    2008-01-01

    Band selection is essential in the design of multispectral sensor systems. This paper describes the TNO hyperspectral band selection tool HYBASE. It calculates the optimum band positions given the number of bands and the width of the spectral bands. HYBASE is used to calculate the minimum number of

  5. The 450-band resolution G- and R-banded standard karyotype of the donkey (Equus asinus, 2n = 62).

    Science.gov (United States)

    Di Meo, G P; Perucatti, A; Peretti, V; Incarnato, D; Ciotola, F; Liotta, L; Raudsepp, T; Di Berardino, D; Chowdhary, B; Iannuzzi, L

    2009-01-01

    Donkey chromosomes were earlier characterized separately by C-, G- and R-banding techniques. However, direct comparisons between G- and R-banding patterns have still not been carried out in this species. The present study reports this comparison at the 450-band level by using replication G- and R-banding patterns. Two sets of synchronized lymphocyte cultures were set up to obtain early (GBA+CBA-banding) and late (RBA-banding) BrdU incorporation. Slides were stained with acridine orange and observed under a fluorescence microscope. Reverse GBA+CBA- and RBA-banded karyotypes at the 450-band level were constructed. To verify G- and R-banding patterns in some acrocentric chromosomes, sequential GBA+CBA/Ag-NORs and RBA/Ag-NORs were also performed. The results of CBA-banding patterns obtained in 12 animals from 2 breeds showed a pronounced polymorphism of heterochromatin, especially in EAS1q-prox. Ideogrammatic representations of G- and R-banded karyotypes were constructed using only one common G- and R-banding nomenclature. In the present study both G- and R-banding patterns and relative ideograms are presented as standard karyotype for this species at the 450-band level. (c) 2009 S. Karger AG, Basel.

  6. Hurricane Spiral Bands.

    Science.gov (United States)

    Guinn, Thomas A.; Schubert, Wayne H.

    1993-10-01

    The spiral bands that occur in tropical cyclones can be conveniently divided into two classes-outer bands and inner bands. Evidence is presented here that the outer bands form as the result of nonlinear effects during the breakdown of the intertropical convergence zone (ITCZ) through barotropic instability. In this process a zonal strip of high potential vorticity (the ITCZ shear zone or monsoon trough) begins to distort in a varicose fashion, with the potential vorticity (PV) becoming pooled in local regions that are connected by filaments of high PV. As the pooled regions become more axisymmetric, the filaments become thinner and begin to wrap around the PV centers.It is argued that inner bands form in a different manner. As a tropical cyclone intensifies due to latent heat release, the PV field becomes nearly circular with the highest values of PV in the cyclone center. The radial gradient of PV provides a state on which PV waves (the generalization of Rossby waves) can propagate. The nonlinear breaking of PV waves then leads to an irreversible distortion of the PV contours and a downgradient flux of PV. The continuation of this proem tends to erode the high PV core of the tropical cyclone, to produce a surrounding surf zone, and hence to spread the PV horizontally. In a similar fashion, inner bands can also form by the merger of a vortex with a patch of relatively high PV air. As the merger proem occurs the patch of PV is quickly elongated and wrapped around the vortex. The resulting vortex is generally larger in horizontal extent and exhibits a spiral band of PV.When the formation of outer and inner bands is interpreted in the context of a normal-mode spectral model, they emerge as slow manifold phenomena; that is, they have both rotational and (balanced or slaved) gravitational mode aspects. In this sense, regarding them as simply gravity waves leads to an incomplete dynamical picture.

  7. Replication patterns and no differential banding in Colombian squirrels, Sciurus (rodentia, sciuridae)

    International Nuclear Information System (INIS)

    Arango, Carolina; Bueno, Marta Lucia

    2012-01-01

    Colombian Squirrels cytogenetic showed a great variability which has renewed the interest in evolutionary aspects within the group. Many chromosome banding tools must be analyzed carefully in addition to the classical G-banding G technique. These techniques include other differential bands like Q and R banding and no differential banding (C and NOR). In this article the use of each of these supplements in the cytogenetic analysis of species and cytotypes observations for the Colombian squirrels is explained.

  8. Mesenteric artery contraction and relaxation studies using automated wire myography.

    Science.gov (United States)

    Bridges, Lakeesha E; Williams, Cicely L; Pointer, Mildred A; Awumey, Emmanuel M

    2011-09-22

    Proximal resistance vessels, such as the mesenteric arteries, contribute substantially to the peripheral resistance. These small vessels of between 100-400 μm in diameter function primarily in directing blood flow to various organs according to the overall requirements of the body. The rat mesenteric artery has a diameter greater than 100 μm. The myography technique, first described by Mulvay and Halpern(1), was based on the method proposed by Bevan and Osher(2). The technique provides information about small vessels under isometric conditions, where substantial shortening of the muscle preparation is prevented. Since force production and sensitivity of vessels to different agonists is dependent on the extent of stretch, according to active tension-length relation, it is essential to conduct contraction studies under isometric conditions to prevent compliance of the mounting wires. Stainless steel wires are preferred to tungsten wires because of oxidation of the latter, which affects recorded responses(3).The technique allows for the comparison of agonist-induced contractions of mounted vessels to obtain evidence for normal function of vascular smooth muscle cell receptors. We have shown in several studies that isolated mesenteric arteries that are contracted with phenylyephrine relax upon addition of cumulative concentrations of extracellular calcium (Ca(2+)(e;)). The findings led us to conclude that perivascular sensory nerves, which express the G protein-coupled Ca(2+)-sensing receptor (CaR), mediate this vasorelaxation response. Using an automated wire myography method, we show here that mesenteric arteries from Wistar, Dahl salt-sensitive(DS) and Dahl salt-resistant (DR) rats respond differently to Ca(2+)(e;). Tissues from Wistar rats showed higher Ca(2+)-sensitivity compared to those from DR and DS. Reduced CaR expression in mesenteric arteries from DS rats correlates with reduced Ca(2+)(e;)-induced relaxation of isolated, pre-contracted arteries. The data

  9. Band structure analysis in SiGe nanowires

    International Nuclear Information System (INIS)

    Amato, Michele; Palummo, Maurizia; Ossicini, Stefano

    2012-01-01

    One of the main challenges for Silicon-Germanium nanowires (SiGe NWs) electronics is the possibility to modulate and engine their electronic properties in an easy way, in order to obtain a material with the desired electronic features. Diameter and composition constitute two crucial ways for the modification of the band gap and of the band structure of SiGe NWs. Within the framework of density functional theory we present results of ab initio calculations regarding the band structure dependence of SiGe NWs on diameter and composition. We point out the main differences with respect to the case of pure Si and Ge wires and we discuss the particular features of SiGe NWs that are useful for future technological applications.

  10. Band structure analysis in SiGe nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Michele [' Centro S3' , CNR-Istituto Nanoscienze, via Campi 213/A, 41100 Modena (Italy); Dipartimento di Scienze e Metodi dell' Ingegneria, Universita di Modena e Reggio Emilia, via Amendola 2 Pad. Morselli, I-42100 Reggio Emilia (Italy); Palummo, Maurizia [European Theoretical Spectroscopy Facility (ETSF) (Italy); CNR-INFM-SMC, Dipartimento di Fisica, Universita di Roma, ' Tor Vergata' , via della Ricerca Scientifica 1, 00133 Roma (Italy); Ossicini, Stefano, E-mail: stefano.ossicini@unimore.it [' Centro S3' , CNR-Istituto Nanoscienze, via Campi 213/A, 41100 Modena (Italy) and Dipartimento di Scienze e Metodi dell' Ingegneria, Universita di Modena e Reggio Emilia, via Amendola 2 Pad. Morselli, I-42100 Reggio Emilia (Italy) and European Theoretical Spectroscopy Facility - ETSF (Italy) and Centro Interdipartimentale ' En and Tech' , Universita di Modena e Reggio Emilia, via Amendola 2 Pad. Morselli, I-42100 Reggio Emilia (Italy)

    2012-06-05

    One of the main challenges for Silicon-Germanium nanowires (SiGe NWs) electronics is the possibility to modulate and engine their electronic properties in an easy way, in order to obtain a material with the desired electronic features. Diameter and composition constitute two crucial ways for the modification of the band gap and of the band structure of SiGe NWs. Within the framework of density functional theory we present results of ab initio calculations regarding the band structure dependence of SiGe NWs on diameter and composition. We point out the main differences with respect to the case of pure Si and Ge wires and we discuss the particular features of SiGe NWs that are useful for future technological applications.

  11. Mixed and dynamic response of hot wires and cold wires and measurements of turbulence statistics

    DEFF Research Database (Denmark)

    Larsen, Søren Ejling; Højstrup, Jørgen; Fairall, C. W.

    1986-01-01

    Hot wires respond to temperature as well as to velocity, whereas cold wires respond to velocity as well as to temperature. The static and dynamic response characteristics are summarized and it is shown that the frequency transfer functions for the four different responses in general are different...

  12. Modeling and simulation of the fluid flow in wire electrochemical machining with rotating tool (wire ECM)

    Science.gov (United States)

    Klocke, F.; Herrig, T.; Zeis, M.; Klink, A.

    2017-10-01

    Combining the working principle of electrochemical machining (ECM) with a universal rotating tool, like a wire, could manage lots of challenges of the classical ECM sinking process. Such a wire-ECM process could be able to machine flexible and efficient 2.5-dimensional geometries like fir tree slots in turbine discs. Nowadays, established manufacturing technologies for slotting turbine discs are broaching and wire electrical discharge machining (wire EDM). Nevertheless, high requirements on surface integrity of turbine parts need cost intensive process development and - in case of wire-EDM - trim cuts to reduce the heat affected rim zone. Due to the process specific advantages, ECM is an attractive alternative manufacturing technology and is getting more and more relevant for sinking applications within the last few years. But ECM is also opposed with high costs for process development and complex electrolyte flow devices. In the past, few studies dealt with the development of a wire ECM process to meet these challenges. However, previous concepts of wire ECM were only suitable for micro machining applications. Due to insufficient flushing concepts the application of the process for machining macro geometries failed. Therefore, this paper presents the modeling and simulation of a new flushing approach for process assessment. The suitability of a rotating structured wire electrode in combination with an axial flushing for electrodes with high aspect ratios is investigated and discussed.

  13. STRS SpaceWire FPGA Module

    Science.gov (United States)

    Lux, James P.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.

    2011-01-01

    An FPGA module leverages the previous work from Goddard Space Flight Center (GSFC) relating to NASA s Space Telecommunications Radio System (STRS) project. The STRS SpaceWire FPGA Module is written in the Verilog Register Transfer Level (RTL) language, and it encapsulates an unmodified GSFC core (which is written in VHDL). The module has the necessary inputs/outputs (I/Os) and parameters to integrate seamlessly with the SPARC I/O FPGA Interface module (also developed for the STRS operating environment, OE). Software running on the SPARC processor can access the configuration and status registers within the SpaceWire module. This allows software to control and monitor the SpaceWire functions, but it is also used to give software direct access to what is transmitted and received through the link. SpaceWire data characters can be sent/received through the software interface, as well as through the dedicated interface on the GSFC core. Similarly, SpaceWire time codes can be sent/received through the software interface or through a dedicated interface on the core. This innovation is designed for plug-and-play integration in the STRS OE. The SpaceWire module simplifies the interfaces to the GSFC core, and synchronizes all I/O to a single clock. An interrupt output (with optional masking) identifies time-sensitive events within the module. Test modes were added to allow internal loopback of the SpaceWire link and internal loopback of the client-side data interface.

  14. Recycling of electronic waste: Printed wiring boards

    Science.gov (United States)

    Luyima, Alex

    Pyrolysis and leaching are the dominant techniques applied in the recycling of waste printed wiring boards (PWBs). Waste PWB pyrolysis is a highly polluting technology and produces brominated pyrolysis oils in addition to hydrogen bromide (HBr) gas. Moreover, leaching as a treatment process of waste PWBs is not well investigated. In this work, the pyrolysis of waste PWBs has been studied with the aim of reducing the amount of brominated oils and HBr gas evolved. The effects of powder inorganic chemicals (CaO, CaCO3, Fe 2O3, Al2O3, Y-Zeolite, and ZSM-5) additions on the pyrolysis of waste PWBs has been studied through experiments using a thermogravimetric-differential thermal analyzer connected to a mass spectrometer (TG-DTA-MS) and in a tube furnace at 900 °C. It has been shown that the kinetic models by Friedman, Flynn-Wall-Ozawa, and Kissinger are applicable to waste PWB pyrolysis at temperatures below 400 °C. Moreover, CaO, CaCO3, Fe2O3, Y-Zeolite, and ZSM-5 show a potential to reduce the amount of HBr gas evolved during pyrolysis in TG-DTA-MS. However, in the tube furnace pyrolysis experiments, CaO and CaCO3 were found to be the most effective chemical additions, with more than 90% reduction in total bromine (HBr and other brominated gases) evolved. It has also been demonstrated that the sequential leaching of waste PWBs with hydrochloric acid, nitric acid and aqua regia is capable of selective recovery of base and precious metals contained in waste PWBs.

  15. Shaping ability of two M‑wire and two traditional nickel‑titanium ...

    African Journals Online (AJOL)

    2015-02-24

    Feb 24, 2015 ... Ceyhanli, et al.: Shaping ability of different NiTi systems. 714. Nigerian Journal of Clinical Practice • Nov-Dec 2015 • Vol 18 • Issue 6 procedural errors ... manufacturing methods, and preparation techniques regarding rotary endodontic instruments made of NiTi alloy. Recently, a special NiTi wire called.

  16. Synthsis of Networks Consisting of Capacitors and 2-Wire Coupled Lines

    OpenAIRE

    Fujimoto, Hideaki

    2004-01-01

    Necessary and sufficient conditions are presented under which a 2x2 2-variable admittance matrix may be realized as a 2-port network in which a 4-port network consisting of capacitors only is terminated in a 2-port network consisting of 2-wire coupled lines. Furthermore, an example is given to illustrate the synthesis technique.

  17. An hp-adaptive strategy for the solution of the exact kernel curved wire Pocklington equation

    NARCIS (Netherlands)

    D.J.P. Lahaye (Domenico); P.W. Hemker (Piet)

    2007-01-01

    textabstractIn this paper we introduce an adaptive method for the numerical solution of the Pocklington integro-differential equation with exact kernel for the current induced in a smoothly curved thin wire antenna. The hp-adaptive technique is based on the representation of the discrete solution,

  18. Design of Wire Antennas by Using an Evolved Particle Swarm Optimization Algorithm

    NARCIS (Netherlands)

    Lepelaars, E.S.A.M.; Zwamborn, A.P.M.; Rogovic, A.; Marasini, C.; Monorchio, A.

    2007-01-01

    A Particle Swarm Optimization (PSO) algorithm has been used in conjunction with a full-wave numerical code based on the Method of Moments (MoM) to design and optimize wire antennas. The PSO is a robust stochastic evolutionary numerical technique that is very effective in optimizing multidimensional

  19. A Hot-Wire Method Based Thermal Conductivity Measurement Apparatus for Teaching Purposes

    Science.gov (United States)

    Alvarado, S.; Marin, E.; Juarez, A. G.; Calderon, A.; Ivanov, R.

    2012-01-01

    The implementation of an automated system based on the hot-wire technique is described for the measurement of the thermal conductivity of liquids using equipment easily available in modern physics laboratories at high schools and universities (basically a precision current source and a voltage meter, a data acquisition card, a personal computer…

  20. Eddy-correlation measurements above a maize crop using a simple cruciform hot-wire anemometer

    NARCIS (Netherlands)

    Bottemanne, F.A.

    1979-01-01

    For measurements of the vertical transport of heat and momentum in the turbulent and slightly unstable boundary layer above a maize crop eddy-correlation techniques were applied. In addition to a vertical Gill-propellor anemometer and a Gill-propellor bivane, a cruciform hot-wire probe, mounted on a