WorldWideScience

Sample records for balloon-guided repeat self-expanding

  1. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  2. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    Science.gov (United States)

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  3. In Vitro Comparison of Self-Expanding Versus Balloon-Expandable Stents in a Human Ex Vivo Model

    International Nuclear Information System (INIS)

    Grenacher, Lars; Rohde, Stefan; Gaenger, Ellen; Deutsch, Jochen; Kauffmann, Guenter W.; Richter, Goetz M.

    2006-01-01

    The objective was to compare the radial strength and expansile precision of self-expanding stents and balloon-expandable stents in a human cadaver bifurcation model. Seven different self-expanding (LUMINEXX, JOSTENT SelfX, JOSTENT SelfX hrf, Sinus-Repo, Sinus SuperFlex, Easy Wallstent, SMART) and four different balloon-expandable stent models (Palmaz, Sinus Stent, SAXX Medium, JOSTENT peripheral), each type 10 stents (total n = 110 stents) were implanted into the common iliac arteries of human cadaver corpses. The maximum stent diameter was 10 mm for all models. After stent implantation, the specimens were filled with silicone caoutchouc. After 24 h, the vascular walls including the stents were removed from the hardened casts. Diameters were taken and the weight of the cast cylinders was measured in air and in purified water to calculate the volume of the bodies (according to Archimedes Law) as a relative but precise degree for the radial strength of the implanted stents. The cylindrical casts of the self-expanding stents showed lower mean diameters (8.2 ± 1.0 mm) and mean volumes (0.60 ± 0.14 ml/cm) than in the balloon-expandable stent group (10.1 ± 0.3 mm and 0.71 ± 0.04 ml/cm, respectively; p < 0.01). The nominal maximum diameter of 10 mm was not achieved in any of the self-expanding stents, but this was achieved in more than 70% (29/40) of the balloon-expandable stent specimens (p < 0.05). The variation between achieved volumes was significantly larger in self-expanding (range: 0.23-0.78 ml/cm) than in balloon-expandable stents (range: 0.66-0.81 ml/cm; p < 0.05). Self-expanding stents presented considerably lower radial expansion force and lower degree of precision than balloon-expandable stents

  4. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H. [Robert Janker Klinik, Bonn (Germany); Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany); Miloslavski, E.; Lowens, S.; Reinartz, J. [Robert Janker Klinik, Bonn (Germany); Liebig, T.; Kuehne, D. [Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany)

    2005-03-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  5. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    International Nuclear Information System (INIS)

    Henkes, H.; Miloslavski, E.; Lowens, S.; Reinartz, J.; Liebig, T.; Kuehne, D.

    2005-01-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  6. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-01-01

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  7. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd

    2007-01-01

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  8. Differences in Endothelial Injury After Balloon Angioplasty, Insertion of Balloon-Expanded Stents or Release of Self-Expanding Stents: An Electron Microscopic Experimental Study

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Carlemalm, Erik; Cwikiel, Wojciech

    1999-01-01

    Purpose: To evaluate which of six different commonly available stents inserted into an artery without percutaneous transluminal angioplasty (PTA) causes the least endothelial damage. To compare the degree of endothelial injury after insertion of such a stent with injury caused by PTA. Methods: Twelve healthy pigs were used in the experiments. In the first part of the study six different types of stents were inserted into the common iliac arteries. In the second part of the study self-expanding stents with large spaces between the wires were used. PTA was performed in the contralateral iliac artery. The pigs were killed immediately after the procedure and resected specimens examined after fixation, using scanning electron microscopy. Results: All procedures but two were accomplished successfully. More endothelium was preserved after insertion of self-expanding stents with large spaces between the wires, compared with stents with small spaces and balloon-expanded stents. After insertion of self-expanding stents with large spaces, 50.1% ± 16.4% of the endothelium remained intact, compared with only 5.6% ± 7.7% after PTA. The difference was statistically significant (p < 0.001). Conclusion: Self-expanding stents with large spaces between the wires, inserted without PTA, cause less damage to the endothelium than other stents and significantly less damage than PTA

  9. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  10. Covered Balloon-Expanding Stents in Airway Stenosis.

    Science.gov (United States)

    Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik

    2017-04-01

    The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (Pstent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.

  11. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial.

    Science.gov (United States)

    Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong

    2016-06-25

    The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.

  12. Soft tissue expansion before vertical ridge augmentation: Inflatable silicone balloons or self-filling osmotic tissue expanders?

    Directory of Open Access Journals (Sweden)

    Prasad Vijayrao Dhadse

    2014-01-01

    Full Text Available Recent advances in periodontal plastic surgical procedures allow the clinician to reconstruct deficient alveolar ridges in more predictable ways than previously possible. Placement of implant/s in resorbed ridges poses numerous challenges to the clinician for successful esthetic and functional rehabilitation. The reconstruction frequently utilizes one or combination of periodontal plastic surgical procedures in conjunction with autogenous bone grafting, allogenic bone block grafting, ridge split techniques, distraction osteogenesis, or guided bone regeneration (GBR for most predictable outcomes. Current surgical modalities used in reconstruction of alveolar ridge (horizontal and/or vertical component often involve the need of flap transfer. Moreover, there is compromise in tissue integrity and color match owing to different surgical site and the tissue utilized is insufficient in quantity leading to post surgical graft exposition and/or loss of grafted bone. Soft tissue expansion (STE by implantation of inflatable silicone balloon or self filling osmotic tissue expanders before reconstructive surgery can overcome these disadvantages and certainly holds a promise for effective method for generation of soft tissue thereby achieving predictable augmentation of deficient alveolar ridges for the implant success. This article focuses and compares these distinct tissue expanders for their clinical efficacy of achieving excess tissue that predominantly seems to be prerequisite for ridge augmentation which can be reasonably followed by successful placement of endosseous fixtures.

  13. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    OpenAIRE

    Mohamed Shaker; Ahmed Deif; Amr Abdelaal

    2016-01-01

    Objectives: To evaluate the role of fluoroscopic guided self expanding metallic stents in the management of dysphagia caused by malignant esophageal strictures. Materials and methods: During the period between April 2010 and October 2012, 31 patients with malignant esophageal strictures were subjected to fluoroscopic guided self expanding metallic stent application. The study included 22 males and 9 females ranging in age between 22 and 75 years old with mean age of 56.8 years. Lesions wer...

  14. Renal Transplant Ureteral Stenosis: Treatment by Self-Expanding Metallic Stent

    International Nuclear Information System (INIS)

    Cantasdemir, Murat; Kantarci, Fatih; Numan, Furuzan; Mihmanli, Ismail; Kalender, Betul

    2003-01-01

    We report the use of a metallic stent in a transplant ureteral stenosis. A 28-year-old man with chronic renal failure due to chronic pyelonephritis, who received a living-donor renal transplant, presented with transplant ureteral stenosis. The stenosis was unresponsive to balloon dilation and was treated by antegrade placement of a self-expanding Memotherm stent. The stentedureter stayed patent for 3 years. It may be reasonable to treat post-transplant ureteral stenosis resistant to balloon dilation with self-expanding metallic stents. However, long-term follow-up is required to evaluate the efficacy of this treatment

  15. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    Energy Technology Data Exchange (ETDEWEB)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de; Kurre, Wiebke, E-mail: w.kurre@klinikum-stuttgart.de [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany); Schmid, Elisabeth, E-mail: ESchmid@klinikum-stuttgart.de; Baezner, Hansjoerg, E-mail: H.Baezner@klinikum-stuttgart.de [Klinikum Stuttgart, Klinik fuer Neurologie, Neurozentrum (Germany); Henkes, Hans, E-mail: hhhenkes@aol.com [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany)

    2013-04-15

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  16. Membrane-like structure in the urinary bladder neck of a young cat: diagnosis and treatment using balloon dilatation and a balloon-expandable metallic stent

    Directory of Open Access Journals (Sweden)

    Matias Ruiz-Drebing

    2017-10-01

    Full Text Available Case summary A 33-month-old, spayed female domestic shorthair cat was referred to the Animal Health Trust for the investigation of urinary incontinence and straining to urinate. A membrane-like structure was detected in the bladder neck, which caused partial obstruction of the urinary bladder. A combination of different imaging techniques, including ultrasonography, radiography, CT and fluoroscopy, was essential in the diagnosis, surgical planning and treatment of this intravesicular stricture. During retrograde vaginourethrocystogram, unexpected subcapsular accumulation of contrast medium was seen around both kidneys on radiographs and confirmed with CT. Three different treatments were performed, including surgical debridement, balloon dilatation and placement of a self-expanding metallic stent across the stricture. Histopathology of the membrane was unable to differentiate whether the lesion was congenital or acquired. No urinary incontinence was observed 5 months after placement of the metallic stent. Relevance and novel information This is the first reported case using fluoroscopic-guided balloon dilatation of the bladder neck for the treatment of a bladder neck stricture. Presence of renal subcapsular contrast medium secondary to a retrograde vaginourethrocystogram due to partial obstruction at the bladder neck in a cat has not been previously described.

  17. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    International Nuclear Information System (INIS)

    Vajda, Zsolt; Güthe, Thomas; Perez, Marta Aguilar; Kurre, Wiebke; Schmid, Elisabeth; Bäzner, Hansjörg; Henkes, Hans

    2013-01-01

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54–86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  18. Collapse of the balloon-expandable stent in the common iliac artery due to minor external compression in a lean patient

    International Nuclear Information System (INIS)

    Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun; Cho, Su Beom; Ahn, Jong Hwa

    2017-01-01

    A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure

  19. Self-expanding intracoronary stents in the treatment of coronary artery disease: new developments and future directions

    NARCIS (Netherlands)

    Lu, H.; Grundeken, M. J.; Koch, K. T.; Wykrzykowska, J. J.

    2013-01-01

    The first stent implanted in the human coronary circulation was a self-expandable (SE) stent and was introduced almost simultaneously with the first balloon-expandable (BE) stents in the late 1980s. Nowadays, the majority of the available stents are delivered by balloon expansion. While BE stents

  20. Collapse of the balloon-expandable stent in the common iliac artery due to minor external compression in a lean patient

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun [Gyeongsang National University School of Medicine and Gyeongsang National University Hospital, Jinju (Korea, Republic of); Cho, Su Beom; Ahn, Jong Hwa [Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon (Korea, Republic of)

    2017-08-15

    A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure.

  1. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  3. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  4. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  5. Self-expandable metal stents in the treatment of benign anastomotic stricture after rectal resection for cancer.

    Science.gov (United States)

    Lamazza, A; Fiori, E; Sterpetti, A V; Schillaci, A; Scoglio, D; Lezoche, E

    2014-04-01

    To evaluate the use of self-expandable metallic stents to treat patients with symptomatic benign anastomotic stricture after colorectal resection. Ten patients with a benign symptomatic anastomotic stricture after colorectal resection were treated with endoscopic placement of a self-expandable metal stent. The stent was placed successfully in all 10 patients without any major morbidity. At a mean follow-up of 18 months the stenosis was resolved successfully in 7 out 10 patients (70%). The remaining three patients were subsequently treated successfully with balloon dilatation. Self-expandable metal stents represent a valid alternative to balloon dilatation to treat patients with benign symptomatic anastomotic stricture after colorectal resection for cancer. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  6. Teacher's Guide for Balloons and Gases.

    Science.gov (United States)

    Griffith, Joe H.; And Others

    This guide was developed to provide children with an opportunity to prepare and collect several common gases and to discover and work with some of their properties. The guide is divided into five major sections: (1) introduction, (2) materials, (3) activities, (4) balloons aloft, and (5) an appendix. The introduction provides information…

  7. Response of Balloon-Expandable Endoprosthetic Metallic Stents Subjected to Over-Expansion In Vitro

    International Nuclear Information System (INIS)

    Montague, B. J.; Kakimoto, W. M.; Arepally, A.; Razavi, M.; Dake, M. D.; Hofmann, L. V.

    2004-01-01

    We attempted to evaluate the in vitro behavior and performance of balloon-expandable endoprosthetic metallic stents subjected to over-expansion (OE). Seventy-two balloon-expandable endoprosthetic stents, representing 22 models from six manufacturers, were over- expanded in vitro. Stents were initially expanded to their maximum manufacturer- recommended diameter and then over-expanded incrementally to their endpoints. Endpoints for OE were either stent disarticulation or an inability to undergo further expansion despite balloon insufflation to maximum burst pressure. Measurements of stent dimensions were recorded at each overexpanded diameter and comparisons were made to manufacturer's specifications. A total of 288 balloon-driven expansions were performed on 72 stents. Sixteen stents were expanded to large diameters (≥ 16 mm), 20 stents underwent OE of 50% or greater. One model tended to disarticulate after OE greater than 50%. There were five models that had a tendency to disarticulate after minimal OE. Five models were resistant to OE (25% or less OE) but did not disarticulate. Nearly all stents showed some degree of foreshortening with OE, while 36 stents underwent foreshortening of 30% or more. Models that are not recommended for OE include Intrastent, Intrastent DoubleStrut, NIR Royale and Omniflex. Good candidates for OE include Intrastent DoubleStrut LD, Palmaz large, Medtronic Extra Support Biliary Plus and Medtronic Flexible Biliary. Palmaz XL remains the only model available for expansion from 20 to 28 mm in diameter. For the remaining stents, OE is possible, however, caution should be used

  8. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  9. Esophageal achalasia : results of balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-08-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia.

  10. Esophageal achalasia : results of balloon dilation

    International Nuclear Information System (INIS)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young

    1996-01-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia

  11. Balloon dilation and airway stenting for benign and malignant tracheal stenosis

    International Nuclear Information System (INIS)

    Guo Jianhai; Yang Renjie; Zhang Hongzhi

    2009-01-01

    Objective: To assess the effectiveness of balloon dilation and airway stenting performed under fluoroscopic guidance for the treatment of benign and malignant tracheal stenosis. Methods: Under fluoroscopic guidance, balloon dilation and airway stenting were performed in 45 patients with tracheobronchial stricture. Of the 45 patients,malignant tracheal stenosis was seen in 37, including mediastinal nodal metastases (n=14), esophageal carcinoma (n=13), lung carcinoma (n= 4), adenocarcinoma of bronchus (n=3), lymphoma (n=2) and laryngocarcinoma (n=1), and benign tracheal stenosis was seen in 8, including endobronchial tuberculosis (n=6), retrosternal thyroid adenoma (n=1) and endotracheal intubation (n=1). Airway stenting with self-expandable metal stent was employed in 38 patients and balloon dilation in 7 patients. All the procedures were performed under fluoroscopic guidance. Results: A total of 53 self-expandable metal stents was implanted in 38 patients. The clinical symptoms were immediately relived after the procedure in all patients except for one patient who died from choking of sputum. No stent migration was observed. Restenosis developed in 4 patients, which was successfully treated with repeated stenting and balloon dilation. Nineteen times of balloon dilation procedure were accomplished in 7 patients. Marked remission of clinical symptoms was seen in most cases. During a follow-up period (ranged from 0 to 124 months with a mean of 24.5 months) 31 patients died. Conclusion: For both benign and malignant tracheal stenosis, balloon dilation with airway stenting performed under fluoroscopic guidance is a safe and efficient therapy with instant curative effect in relieving clinical symptoms. (authors)

  12. Fluoroscopy-guided balloon dilation in patients with Eustachian tube dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho-Young [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Park, Hong Ju; Kang, Woo Seok [University of Ulsan College of Medicine, Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, Seoul (Korea, Republic of); Park, Jung-Hoon [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); University of Ulsan College of Medicine, Department of Biomedical Engineering Research Center, Asan Medical Center, Seoul (Korea, Republic of); Wang, Zhe [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Tianjin Medical University General Hospital, Department of Radiology (China)

    2018-03-15

    To prospectively evaluate the technical feasibility and safety of fluoroscopy-guided balloon dilation in patients with Eustachian tube (ET) dysfunction. Patients who could not do a Valsalva manoeuvre for more than 6 months and diagnosed with chronic otitis media or ET dysfunction were prospectively enrolled. A 0.035-in. guide wire and 6-mm long balloon catheter with a diameter of 2 mm were used to dilate the cartilaginous portion of the ET under fluoroscopic guidance. The balloon was inflated by manual injection twice for 1 min each time. Clinical outcomes were assessed by the patient's ability to perform a Valsalva manoeuvre, and symptoms were assessed using the 7-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) score. Balloon dilation was attempted in a total of ten adult patients from October 2016 to March 2017. Technical success was achieved in all procedures (10/10). Ninety percent (9/10) of the balloons were fully dilated without waist deformity. There were no major complications. All patients were able to perform a Valsalva manoeuvre at the time of their last visit and/or improvement of at least one ETDQ-7 score. Fluoroscopy-guided balloon dilation seems to be technically feasible and safe in the treatment of ET dysfunction. (orig.)

  13. Image-guided method for TLD-based in vivo rectal dose verification with endorectal balloon in proton therapy for prostate cancer

    International Nuclear Information System (INIS)

    Hsi, Wen C.; Fagundes, Marcio; Zeidan, Omar; Hug, Eugen; Schreuder, Niek

    2013-01-01

    Purpose: To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. Methods: TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markers were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. Results: A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and −10% of the planning dose with a mean of −2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between −10% and −20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10–20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Conclusions: Our results show that image-guided TLD

  14. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    Science.gov (United States)

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. The use of balloon-expandable metallic stents in the treatment of pediatric tracheomalacia and bronchomalacia.

    Science.gov (United States)

    Furman, R H; Backer, C L; Dunham, M E; Donaldson, J; Mavroudis, C; Holinger, L D

    1999-02-01

    To evaluate the use of balloon-expandable metallic stents in the treatment of children with tracheomalacia and bronchomalacia in whom conventional therapy has failed. Retrospective case series. Tertiary pediatric otolaryngology and cardiothoracic surgery referral center. Six patients were identified as having undergone bronchoscopic placement of metallic balloon-expandable stents between 1994 and 1997. The age at stent placement, prior surgical interventions, and indications for and sites of stent placement were noted. Also, the complications related to stent placement and the current airway status of the patients were reviewed. Twelve balloon-expandable metallic angioplasty stents (Palmaz; Johnson & Johnson Interventional Systems Co, Warren, NJ) were placed bronchoscopically in 6 patients. Six stents were placed in the lower trachea, and 6 were placed in the main bronchi. The stents were balloon expanded under fluoroscopic guidance. Discontinuation of mechanical ventilation. The age at stent placement ranged from 1.5 to 38 months (mean age at placement, 10 months). The indications for stent placement were (1) tracheomalacia or bronchomalacia, (2) pericardial patch or slide tracheoplasty failure, and (3) bronchomalacia caused by tetralogy of Fallot and large pulmonary arteries. The primary complication of stent placement was postoperative granulation tissue formation. One patient required the removal of 2 tracheal stents because of granulation tissue formation. There were 2 deaths in the series, 1 possibly related to stent placement. Four of the 6 patients were weaned from mechanical ventilation, and 3 experienced prolonged relief of airway obstruction. Metallic balloon-expandable stents are effective in relieving lower tracheomalacia and bronchomalacia in select patients. Only patients in whom conventional therapy has failed should be considered for stent placement.

  16. Management of stent dislodgment in coarctoplasty of aorta with three overlapping self-expandable nitinol stents.

    Science.gov (United States)

    Ghazi, Payam; Haji-Zeinali, Ali-Mohammad

    2010-01-01

    We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.

  17. Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    Rössle M

    2018-01-01

    Full Text Available The availability of polytetrafluoroethylene (PTFE covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS. Side effects of portosystemic shunting such as hepatic encephalopathy (HE and worsening of hepatic function, however, remained a problem. To reduce HE, underdilatation of nitinol stents has been practiced for many years. However, as shown recently, underdilatation was a flop since, due to their intrinsic memory, nitinol stents always expanded to reach their nominal diameter of 8 or 10 mm. To overcome this problem and to be able to perform permanent shunts with a smaller diameter of < 8 mm, we studied the usefulness of a balloon-expandable, covered, metallic stent which allowed adjustment to any diameter between 5 and 12 mm. Methods: 30 patients with cirrhosis and symptomatic portal hypertension were included. The mean Child-Pugh score was 8 ± 2.17 patients had refractory ascites, 9 patients variceal bleeding and four patients other indications for the TIPS. Results: The TIPS was successfully implanted in all patients within 69.6 ± 21.8 min. The shunt reduced the portosystemic pressure gradient by 57.5 ± 14.2% with a mean stent diameter of 7.4 ± 1.0 mm (5 -10.3 mm. During a mean follow-up of 330 ± 249 days, shunt revision was necessary in 5 patients (17%, four of them had insufficient response and received stent dilatation and one patient had stent misplacement requiring a parallel shunt. Three patients (10% developed HE. Conclusions: The covered, balloon-expandable stent could be placed accurately and allowed creation of adapted shunts with smaller diameters as usual. This resulted in a comparatively low rate of HE.

  18. Treatment of Benign and Malignant Tracheobronchial Obstruction with Metal Wire Stents: Experience with a Balloon-Expandable and a Self-Expandable Stent Type

    International Nuclear Information System (INIS)

    Rieger, Johannes; Hautmann, Hubert; Linsenmaier, Ulrich; Weber, Cristoph; Treitl, Markus; Huber, R.M.; Pfeifer, Klaus-Juergen

    2004-01-01

    Over the last few years various types of metal wire stents have been increasingly employed in the treatment of both malignant and benign tracheobronchial obstruction. To date, however, few studies have investigated the in vivo properties of different stent types. We implanted 26 balloon-expandable tantalum Strecker stents (18 patients) and 18 self-expandable Wallstents (16 patients) into the tracheobronchial system of 30 patients with combined stenting in 4 patients. Mean age was 51 years (range: 0.5-79 years). Malignant disease was present in 23 patients, benign disease in seven patients. Both patients and individual stents were monitored clinically and radiographically. The probability of stents remaining within the tracheobronchial system, and of their remaining undislocated and uncompressed was calculated using Kaplan-Meier analysis for both stent types. Average stent follow-up time was 112 days until explantation and 115 days until patients' death or discharge. Kaplan-Meier analysis revealed a higher probability for the Wallstent to remain within the tracheobronchial system. Dislocation and compression occurred more rarely. Explantation, however, if desired, was more difficult compared to the Strecker stent. The Wallstent also led to the formation of granulation tissue, especially at the proximal stent end, frequently requiring reintervention. Both stent types proved to be effective therapeutic options in the management of obstructive tracheobronchial disease. The mechanical properties of the Strecker stent seem to be less favorable compared to the Wallstent but removal is easy. For benign disease, however, the Wallstent reveals limitations due to significant side effects

  19. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na [Chonnam Univ. College of Medicine, Kwangju (Korea, Republic of)

    1999-04-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate.

  20. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na

    1999-01-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate

  1. Role of Self-Expandable Metal Stents in Acute Variceal Bleeding

    Directory of Open Access Journals (Sweden)

    Fuad Maufa

    2012-01-01

    Full Text Available Acute variceal bleeding continues to be associated with significant mortality. Current standard of care combines hemodynamic stabilization, antibiotic prophylaxis, pharmacological agents, and endoscopic treatment. Rescue therapies using balloon tamponade or transjugular intrahepatic portosystemic shunt are implemented when first-line therapy fails. Rescue therapies have many limitations and are contraindicated in some cases. Placement of fully covered self-expandable metallic stent is a promising therapeutic technique that can be used to control bleeding in cases of refractory esophageal bleeding as an alternative to balloon tamponade. These stents can be left in place for as long as two weeks, allowing for improvement in liver function and institution of a more definitive treatment.

  2. Self-Expanding, Tough Biodegradable Elastomers for Wound Stasis

    Science.gov (United States)

    2015-08-06

    the civilian setting, with no effective therapies available at point of injury. We previously reported that a self- expanding polyurethane foam...setting, with no effective therapies available at point of injury. We previously reported that a self-expanding polyurethane foam significantly...care in accor- dance with the Guide of the Care and Use of Laboratory Ani- mals (Health, 2011 #17). 2.2. Instrumentation and monitoring All swine (n

  3. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    International Nuclear Information System (INIS)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong

    2017-01-01

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT

  5. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong [Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-06-15

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT.

  6. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3.

    Science.gov (United States)

    Arai, Takahide; Hovasse, Thomas; Chevalier, Bernard

    2018-04-01

    The expandable sheath was designed with a lower profile in order to reduce the incidence of vascular complications of transcatheter aortic valve implantation using transfemoral approach. However, once the prosthesis has crossed the sheath, it could be difficult to retrieve it from the body. This is the first case of successful bail-out in an instance of delivery balloon shaft malfunction subsequent to the crossing of an expandable sheath during implantation of an Edwards SAPIEN 3 prosthesis. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Membranous obstruction of inferior vena cava(MOIVC): treatment with percutaneous transluminal angioplasty(PTA) and self expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Yeol; Kim, Baek Hyun; Cha, In Ho; Lee, Nam Joon; Kim, Yun Hwan; Kim, Jung Hyuk [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1994-03-15

    Percutaneous transluminal angioplasty(PTA) with a balloon catheter is a standard method of treatment for membranous obstruction of inferior vena cava(MOIVC). But, correct therapeutic approach has not been established for MOIVC patients whose lesion is associated with extensive thrombotic IVC occlusion. We tried to treat MOIVC associated with or without thrombus. We treated 13 cases of MOIVC(associated with thrombus in 7 cases, no thrombus in 6 cases) with PTA, thrombolysis and self-expandable metallic stents. PTA was successful in 8 cases, but failed in 5 cases. The recurred cases were retreated with PTA, but follow-up study revealed recoiling restenosis in 4 cases and intimal hyperplasia in 1 case at previous PTA site which could be overcome with a self-expandable metallic stent. The complication were occurred in 3 cases which were hemothorax, hemopericardium, and hemoperitoneum respectively. However, those were resolved by conservative treatment only. Recanalization and dilatation could be done in MOIVC patients with or without thrombosis for improvement of patient's symptom. Gianturco self-expandable metallic stent is useful in treatment of recurred MOIVC after balloon dilatation and preventing reocclusion of the IVC after PTA.

  8. [Clinical application of ultrasound guided Fogarty balloon catheter in arterial crisis].

    Science.gov (United States)

    Li, Xiaodong; Wang, Pei; Yu, Changyu; Yan, Xiaowei; Yin, Jing

    2017-10-01

    excellent in 12 cases, good in 8 cases, and fair in 4 cases with an excellent and good rate of 83.3%. Ultrasound guided Fogarty balloon catheter treatment of posterior replantation of arterial crisis can accurately locate the thrombosis, get the thrombus fast and invasive minimally to avoid the blind and repeated thrombectomy, and obtain certain effectiveness.

  9. Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation

    Science.gov (United States)

    Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus

    2012-02-01

    Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.

  10. Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves.

    Science.gov (United States)

    Schaefer, Andreas; Treede, Hendrik; Seiffert, Moritz; Deuschl, Florian; Schofer, Niklas; Schneeberger, Yvonne; Blankenberg, Stefan; Reichenspurner, Hermann; Schaefer, Ulrich; Conradi, Lenard

    2016-01-15

    Paravalvular leakage (PVL) is a known complication of transcatheter aortic valve implantation (TAVI) and is associated with poor outcome. Besides balloon-post-dilatation, valve-in-valve (ViV) procedures can be taken into consideration to control this complication. Herein we present initial experience with use of the latest generation balloon-expandable Edwards Sapien 3® (S3) transcatheter heart valve (THV) for treatment of failing THVs. Between 01/2014 and 12/2014 three patients (two male, age: 71-80 y, log EUROScore I: 11.89 - 32.63) with failing THVs were refered to our institution for further treatment. THV approach with secondary implantation of an S3 was chosen after mutual agreement of the local interdisciplinary heart team at an interval of 533-1119 days from the index procedure. The performed procedures consisted of: S3 in Sapien XT, JenaValve and CoreValve. Successful transfemoral implantation with significant reduction of PVL was achieved in all cases. No intraprocedural complications occurred regarding placement of the S3 with a postprocedural effective orifice area (EOA) of 1.5-2.5 cm(2) and pressure gradients of max/mean 14/6-36/16 mmHg. 30-day mortality was 0%. At the latest follow-up of 90-530 days, all patients are alive and well with satisfactory THV function. Regarding VARC-2 criteria one major bleeding and one TIA was reported. In the instance of moderate or severe aortic regurgitation after TAVI, S3 ViV deployment is an excellent option to reduce residual regurgitation to none or mild. For further assertions concerning functional outcomes long-term results have to be awaited.

  11. The Benefits of Guided Facility Self-Assessments

    Science.gov (United States)

    O'Leary, Keith

    2012-01-01

    A growing number of educational institutions have discovered that a guided self-assessment solution helps them to consistently and cost-effectively obtain facility condition information and make better-informed capital planning decisions. Facility self-assessment employs a consistent, repeatable process for internal staff to quickly assess assets…

  12. Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007).

    Science.gov (United States)

    Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M

    2008-11-01

    To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.

  13. Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten

    Energy Technology Data Exchange (ETDEWEB)

    Landwehr, P; Lackner, K [Wuerzburg Univ. (Germany, F.R.). Inst. fuer Roentgendiagnostik; Goetz, R [Wuerzburg Univ. (Germany, F.R.). Abt. fuer Nephrologie

    1990-09-01

    On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

  14. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  15. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self-expanding

  16. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    Energy Technology Data Exchange (ETDEWEB)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology (Japan)

    2012-12-15

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

  17. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    International Nuclear Information System (INIS)

    Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko

    2012-01-01

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

  18. Treatment of symptomatic high-grade intracranial stenoses with the balloon-expandable Pharos stent: initial experience

    International Nuclear Information System (INIS)

    Kurre, W.; Berkefeld, J.; Mesnil de Rochemont, R. du; Sitzer, M.; Neumann-Haefelin, T.

    2008-01-01

    We report our first clinical experience with a CE-marked flexible monorail balloon-expandable stent for treatment of high-grade intracranial stenoses. Between April 2006 and November 2007 21 patients with symptomatic intracranial stenoses (>70%) were treated with the PHAROS stent. In seven patients, the procedure was performed during acute stroke intervention. Procedural success, clinical complication rates and mid-term follow-up data were prospectively recorded. During a median follow-up period of 7.3 months one additional patient died of an unknown cause 3 months after the intervention. A patient with a significant residual stenosis presented with a new stroke after further progression of the residual stenosis. None of the successfully treated patients experienced ipsilateral stroke. Recanalization of intracranial stenoses with the balloon-expandable Pharos stent is technically feasible. The periprocedural complication rate and mid-term follow-up results were in the range of previously reported case series. This pilot study was limited by the small sample size and severe morbidity of the included patients. Final evaluation of the efficacy of Pharos stent treatment demands further investigation. (orig.)

  19. Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults.

    Science.gov (United States)

    Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam

    2017-09-01

    Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.

  20. Malignant strictures involving the esophagogastric junction : palliative treatment with balloon dilation combined with chemotherapy and/or radiotherapy

    International Nuclear Information System (INIS)

    Hong, Hyoek Jin; Ko, Gi Young; Song, Ho Young; Cho, Yong Soo; Sung, Kyu Bo

    2001-01-01

    To overcome the limitations of expandable metallic stent placement by using balloon dilation combined with chemotherapy or radiation therapy in the treatment of malignant esophageal strictures involving the esophagogastric junction (EGJ). Fluoroscopically guided balloon dilation was performed in 14 patients with strictures due to squamous cell carcinoma (n=5) or adenocarcinoma (n=9). After balloon dilation all patients underwent chemotherapy or radiation therapy. There were no failures or major complications After dilation, dysphagia improved in 13 (92%) of 14 patients, and the long-term success rate was 50%. Six of the seven patients in whom the condition recurred underwent further balloon dilation (n=4) or placement of an expandable metallic stent (n=2). Ten of the 13 who were followed up died after diffuse metastasis. Prior to their eventual death (mean survial, 20 weeks), the dysphagia experienced by seven (70%) of these ten improved, and thus they required no further treatment. Balloon dilation combined with chemotherapy or radiation therapy seems to be a safe and effective secondary therapy for patients with dysphagia due to malignant stricture involving the EGJ

  1. Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

    Science.gov (United States)

    Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi

    2014-04-15

    Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.

    Science.gov (United States)

    Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo

    2018-05-15

    Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Malignant Esophagogastric Junction Obstruction: Efficacy of Balloon Dilation Combined with Chemotherapy and/or Radiation Therapy

    International Nuclear Information System (INIS)

    Ko, Gi-Young; Song, Ho-Young; Hong, Heuk-Jin; Sung, Kyu-Bo; Seo, Tae-Seok; Yoon, Hyun-Ki

    2003-01-01

    Purpose: To assess the efficacy of balloon dilation combined with chemotherapy and/or radiation therapy for palliation of dysphagia due to malignant esophagogastric junction strictures. Methods: Fluoroscopically guided balloon dilation was attempted in 20 patients. The causes of strictures were gastric adenocarcinoma (n = 10) and esophageal squamous cell carcinoma (n = 10). Scheduled chemotherapy and/or radiation therapy followed balloon dilation in all patients. Results: There were no technical failures or major complications. After balloon dilation, 15 (75%) patients showed improvement of dysphagia. No patient complained of reflux esophagitis during the follow-up period. Among the 15 patients, seven needed no further treatment for palliation of dysphagia until their deaths. The remaining eight patients underwent repeat balloon dilation(n = 4) or stent placement (n = 4)3-43 weeks (mean 15 weeks) after the initial balloon dilation because of recurrent dysphagia. Conclusion: Balloon dilation combined with chemotherapy and/or radiation therapy seems to be an easy and reasonably effective palliative treatment for malignant esophagogastric strictures

  4. Intraluminal Palmaz stent implantation. First clinical case report on a balloon-expandable vessel prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Palmaz, J C; Richter, G M; Noeldge, G; Kauffmann, G W; Wenz, W

    1987-12-01

    A 74-year-old patient suffering from severe iliac artery stenosis and claudication was chosen to be the first candidate in the world to receive the Palmaz stent, a balloon-expandable intraluminal stent. This procedure was done in the Department of Radiology, University of Freiburg, FRG. The intervention and postprocedural course were uneventful. His walking distance improved from less than 100 m to unlimited walking capacity. The intra-arterial pressure gradient and ankle-arm pressure ratio also returned to normal.

  5. Usefulness of repeat coronary angiography 24 hours after balloon angioplasty to evaluate early lminal deterioration and facilitate quantitative analysis

    NARCIS (Netherlands)

    G.R. Heyndrickx (Guy); G-J. Laarman (GertJan); H. Suryapranata (Harry); F. Zijlstra (Felix); P.W.J.C. Serruys (Patrick); D.P. Foley (David); A.A. van den Bos (Arjan); J.W. Deckers (Jaap)

    1993-01-01

    textabstractBecause of the unavoidable occurrence of vessel disruption after successful coronary balloon angioplasty, the reliability of quantitative angiographic analysis in that setting has been questioned. For this reason and the suggested occurrence of delayed elastic recoil, repeat angiography

  6. Self-expanding nanoplatinum-coated nitinol devices for atrial septal defect and patent ductus arteriosus closure: a swine model.

    Science.gov (United States)

    Lertsapcharoen, Pornthep; Khongphatthanayothin, Apichai; La-orkhun, Vidhavas; Supachokchaiwattana, Pentip; Charoonrut, Phingphol

    2006-01-01

    Our purpose was to evaluate self-expanding nanoplatinum-coated nitinol devices for transcatheter closure of atrial septal defects and patent ductus arteriosus in a swine model. The devices were braided from platinum-activated nitinol wires and filled with polyester to enhance thrombogenicity. The platinum activation of the nitinol wires was carried out with the help of Nanofusion technology. The coating of platinum covers the exposed surface of the nitinol wires and prevents the release of nickel into the blood stream after the implantation of the device but does not affect its shape memory, which makes the device self-expanding after it is loaded from the catheter. Atrial septal defects were created in 12 piglets by balloon dilation of the patent foramen ovale. The size of the device was selected on the basis of the diameter of the balloon and the size of the defect, measured by transthoracic echocardiography. The devices were successfully deployed in all 12 piglets under fluoroscopic study. Transthoracic color Doppler echocardiograms showed complete closure of the atrial septal defect within 15 minutes of device implantation. Twelve patent ductus arteriosus closure devices were deployed in the right or left subclavian arteries in 10 piglets. Angiograms showed complete occlusion of the subclavian arteries within a few minutes of device deployment. In the atrial septal defect cases, the autopsy findings showed complete organizing fibrin thrombus formation and complete neo-endothelialization on the outer surface of the devices within one week and six weeks of implantation, respectively. The use of self-expanding nanoplatinum-coated nitinol devices for the transcatheter closure of atrial septal defects and patent ductus arteriosus is feasible. The excellent occlusion result and complete neo-endothelialization of the devices in the swine model is an indication of the potential of these devices in human application.

  7. Rectal Balloon for the Immobilization of the Prostate Internal Motion

    International Nuclear Information System (INIS)

    Lee, Sang Kyu; Beak, Jong Geal; Kim, Joo Ho; Jeon, Byong Chul; Cho, Jeong Hee; Kim, Dong Wook; Song, Tae Soo; Cho, Jae Ho; Na, Soo Kyong

    2005-01-01

    The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning same repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal balloon position and verified the isodose distribution of rectum wall at closed prostate. Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficient for treated prostate cancer patients.

  8. A Self-Assessment Guide for Resident Teaching Experiences.

    Science.gov (United States)

    Engle, Janet P; Franks, Amy M; Ashjian, Emily; Bingham, Angela L; Burke, John M; Erstad, Brian L; Haines, Seena L; Hilaire, Michelle L; Rager, Michelle L; Wienbar, Rebecca

    2016-06-01

    The 2015 American College of Clinical Pharmacy (ACCP) Educational Affairs Committee was charged with developing a self-assessment guide for residency programs to quantitatively and qualitatively evaluate the outcomes of resident teaching curricula. After extensively reviewing the literature, the committee developed assessment rubrics modeled after the 2013 ACCP white paper titled "Guidelines for Resident Teaching Experiences" and the revised American Society of Health-System Pharmacists (ASHP) 2014 accreditation standards for PGY1 residencies, which place greater emphasis on the teaching and learning curriculum (TLC) than the previous accreditation standards. The self-assessment guide developed by the present committee can serve as an assessment tool for both basic and expanded TLCs. It provides the criteria for program goals, mentoring, directed readings with topic discussions, teaching experiences, and assessment methodology. For an expanded TLC, the committee has provided additional guidance on developing a teaching philosophy, becoming involved in interactive seminars, expanding teaching experiences, developing courses, and serving on academic committees. All the guidelines listed in the present paper use the measures "not present," "developing," and "well developed" so that residency program directors can self-assess along the continuum and identify areas of excellence and areas for improvement. Residency program directors should consider using this new assessment tool to measure program quality and outcomes of residency teaching experiences. Results of the assessment will help residency programs focus on areas within the TLC that will potentially benefit from additional attention and possible modification. © 2016 Pharmacotherapy Publications, Inc.

  9. Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study

    International Nuclear Information System (INIS)

    He, Xu; Shin, Ji Hoon; Kim, Hyo Cheol; Woo, Cheol Woong; Woo, Sung Ha; Choi, Won Chan; Kim, Jong Gyu; Lim, Jin Oh; Kim, Tae Hyung; Yoon, Chang Jin; Song, Ho Young; Kang, Wee Chang

    2005-01-01

    We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group II was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms (ρ < 0.001). A significant difference was also found between group III and IV for both phantoms (ρ < 0.001). The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body

  10. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  11. Factors leading to tracheobronchial self-expandable metallic stent fracture.

    Science.gov (United States)

    Chung, Fu-Tsai; Lin, Shu-Min; Chen, Hao-Cheng; Chou, Chun-Liang; Yu, Chih-Teng; Liu, Chien-Ying; Wang, Chun-Hua; Lin, Horng-Chyuan; Huang, Chien-Da; Kuo, Han-Pin

    2008-11-01

    This retrospective study was to determine factors that contribute to self-expandable metallic stent fracture in patients with tracheobronchial disease. From 2001 to 2006, 139 patients (age, 62.1 +/- 15.4 years; range, 23-87 years) with benign (n = 62) and malignant (n = 77) tracheobronchial disease received 192 Ultraflex (Boston Scientific, Natick, Mass) self-expandable metallic stents (98 in patients with benign disease and 94 in patients with malignant disease). Seventeen fractured self-expandable metallic stents were found; the incidence was 12.2% (17/139 patients) among patients with tracheobronchial disease. Tortuous airway (odds ratio, 4.06; 95% confidence interval, 1.04-18.34; P = .04) independently predicted self-expandable metallic stent fracture. Most self-expandable metallic stent fractures (64.7%, 11/17) were detected 500 to 1000 days after self-expandable metallic stent implantation. Clinical presentations for patients with fractured self-expandable metallic stents included dyspnea exacerbation (70.6%, 12/17) and cough (23.5%, 4/17). Self-expandable metallic stent fracture is not uncommon in patients with tracheobronchial disease. Tortuous airway is an independent predictor for it. Although management of the fractured self-expandable metallic stent in our study was feasible and safe, self-expandable metallic stents should be restricted to a more select population.

  12. Balloon expandable intraluminal grafting of normal and abnormal renal arteries: Experimental study

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Hayashi, H.; Schatz, R.; Hunter, G.; Tio, F.O.; Garcia, O.

    1986-01-01

    Balloon expandable intraluminal grafts were placed in renal arteries of eight adult dogs and 11 minipigs. The renal arteries were normal in the dogs before graft placement. Two grafts were placed in primary division branches and the rest in the main renal artery. Experimental renal artery stenosis was created in the minipigs by subocclusive ligature of the renal artery with absorbable suture material. Six months later significant renal artery stenoses developed in six pigs and were corrected by graft placement. In the remaining pigs grafts were placed in the opposite normal renal artery because the stenosis caused a small, shrunken kidney in two, and severe spasm or anatomic variations prevented graft placement in three. All grafts remained patent on angiographic and pathologic examinations to a maximum follow-up to 24 weeks

  13. Second Generation Self-Inflating Tissue Expanders: A Two-Year Experience

    Directory of Open Access Journals (Sweden)

    Jamal Omran Al Madani

    2014-01-01

    Full Text Available Background. Tissue expansion is a well-established surgical technique that produces an additional amount of normal skin to cover a defect. This technique is appealing because the skin quality and color are from the patient’s own. The widely used injectable expanders are of great reliability but carry the disadvantage of being painful during injection and most of the time require multiple clinic visits. So the idea of self-inflation became attractive and hydrogel expanders were developed and became widely known for being painless during clinic visit and decrease number of visits. The first generation expanders were modified by adding an enclosing plastic shell to decrease the unopposed expansion that occurred in the first generation expanders, which lead to pressure necrosis of the skin flaps. This made it an attractive option for tissue expansion in children and some adult patients. Patients, Materials, and Methods. Charts of 17 patients were retrospectively reviewed, all of them had second generation self-inflating expanders implanted over a 2-year period for one of two purposes, the treatment of giant nevi or burn scars. Results. Fifteen patients were females and 2 were males. The indication was large burn scar in 14 cases (14/17, in which 47/55 expanders were implanted, and giant nevus in 3/17 cases in which 8/55 expanders were implanted. Extrusion of the expander occurred in 8/55 expanders (14.5%, which occurred in 6/14 patients. The highest percentage of extrusion occurred in the neck in which two out of three expanders extruded; otherwise this complication does not seem to be related to the indication, gender, nor age of the patients. It seems to be that it is technical in nature. The patients did not have to get any injections to fill the tissue expanders, which made the expansion process less painful and more convenient. Conclusion. This seems to be currently the largest published review in which second generation expanders were used

  14. Supra-annular structure assessment for self-expanding transcatheter heart valve size selection in patients with bicuspid aortic valve.

    Science.gov (United States)

    Liu, Xianbao; He, Yuxin; Zhu, Qifeng; Gao, Feng; He, Wei; Yu, Lei; Zhou, Qijing; Kong, Minjian; Wang, Jian'an

    2018-04-01

    To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS. © 2018 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  15. Use of Self-Expanding Stents for the Treatment of Vertebral Artery Ostial Stenosis: a Single Center Experience

    International Nuclear Information System (INIS)

    Chung, Sun Young; Lee, Deok Hee; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul

    2010-01-01

    To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval

  16. Boston's balloon dilatation for treatment of cardiac achalasia

    International Nuclear Information System (INIS)

    Yin Jianguo; Song Jinwen; Yang Yan; Liu Xiaohong; Fu Zhiming; Zhang Yaqin

    2001-01-01

    Objective: To review and summarize effectiveness and method of the Boston's balloon dilation in cardiac achalasia. Methods: The intensified guide wire was inserted into stomach through mouth cavity under TV control. The Boston's balloon was inserted to the cardiac stricture through the guide wire and dilatated with 15% contrast medium with to a maximum diameter for five minutes and then the balloon was dilatated again for 3-5 minutes, all together for 3-4 times. The severe stricture must be pre-dilatated with 20-25 mm diameter balloon. Results: The balloon insertion was technically successful in all 26 patients. The once success of balloon dilation was achieved in 24 patients and twice in other 2. Follow-up time was from 2 weeks to 31 months (mean 10.6 months). Recurrent stenosis had not occurred in all patients. Remission rate of dysphagia was 100%. Esophageal reflux occurred in 3 patients. Conclusions: The Boston's balloon dilatation is simple and effective for treatment of cardiac achalasia. The method sometimes may replace surgical procedure

  17. Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward; Patel, Rahul S.; Scott Nowakowski, F.; Lookstein, Robert A.; Fischman, Aaron M. [Icahn School of Medicine at Mount Sinai, Interventional Radiology Section, Department of Radiology (United States)

    2016-06-15

    PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

  18. Efficacy of a Self-Expandable Porous Stent as the Sole Curative Treatment for Extracranial Carotid Pseudoaneurysms.

    Science.gov (United States)

    Chen, Peng Roc; Edwards, Nancy J; Sanzgiri, Aditya; Day, Arthur L

    2016-04-01

    Extracranial carotid pseudoaneurysms are uncommon vascular lesions. Even with conservative management complications can happen, such as delayed cerebral embolization or symptoms due to flow limitation. Although endovascular therapy can be curative, literature demonstrating a preferred technique is scant. Our goal was to evaluate the use of 1 technique only-the deployment of overlapping self-expandable porous stents-to treat a series of extracranial carotid pseudoaneurysms. From 2008 to 2014, 14 consecutive cases of symptomatic extracranial carotid pseudoaneurysms were managed with single or multilayer porous stents at our institution. Each patient underwent a standardized angiographic follow-up at 6 months. Twelve patients also received a follow-up computed tomography angiogram at 12 months, and yearly thereafter (median radiographic follow-up, 38 months). The total clinical follow-up period ranged between 6 and 69 months (median, 46 months). In our series, each of the extracranial carotid pseudoaneurysms appeared to be the result of carotid artery dissection with associated carotid stenosis at the origin of every pseudoaneurysm. Endovascular treatment consisted of 1-3 layers of self-expandable porous stents placed without balloon angioplasty. Immediately after stenting angiographic images were notable for stagnant opacification of the pseudoaneurysm through the stent(s). All pseudoaneurysms were completely obliterated by the 6-month follow-up angiogram and remained so throughout the radiographic follow-up period. Complications were minimal, consisting of 1 patient developing a mild Horner's syndrome after treatment that resolved during clinical follow-up. Extracranial carotid pseudoaneurysms can be successfully obliterated with the use of porous, self-expandable stents. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Treatment of Esophageal Variceal Hemorrhage with Self-Expanding Metal Stents as a Rescue Maneuver in a Swiss Multicentric Cohort

    Directory of Open Access Journals (Sweden)

    Fabienne C. Fierz

    2013-03-01

    Full Text Available Acute esophageal variceal bleeding in patients with portal hypertension remains a complication with a high mortality today. In cases refractory to standard therapy including endoscopic band ligation and pharmacological therapy, traditionally balloon tamponade has been used as salvage therapy. However, these techniques show several important limitations. Self-expanding metal stents (SEMS have been proposed as an alternative rescue treatment. The use of variceal stenting in 7 patients with a total of 9 bleeding episodes in three different Swiss hospitals is demonstrated. While immediate bleeding control is achieved in a high percentage of cases, the 5-day and 6-week mortality rate remain high. Mortality is strongly influenced by the severity of the underlying liver disease. Accordingly, our data represent a high-risk patient collective. Thanks to their safety and easy handling, SEMS are an interesting alternative to balloon tamponade as a bridging intervention to definitive therapy including the pre-hospital setting.

  20. Primary stent placement for recanalization of iliac artery occlusions: Using a self-expanding spiral stent

    International Nuclear Information System (INIS)

    Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun

    1999-01-01

    Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.

  1. RNA FISH for detecting expanded repeats in human diseases.

    Science.gov (United States)

    Urbanek, Martyna O; Krzyzosiak, Wlodzimierz J

    2016-04-01

    RNA fluorescence in situ hybridization (FISH) is a widely used technique for detecting transcripts in fixed cells and tissues. Many variants of RNA FISH have been proposed to increase signal strength, resolution and target specificity. The current variants of this technique facilitate the detection of the subcellular localization of transcripts at a single molecule level. Among the applications of RNA FISH are studies on nuclear RNA foci in diseases resulting from the expansion of tri-, tetra-, penta- and hexanucleotide repeats present in different single genes. The partial or complete retention of mutant transcripts forming RNA aggregates within the nucleoplasm has been shown in multiple cellular disease models and in the tissues of patients affected with these atypical mutations. Relevant diseases include, among others, myotonic dystrophy type 1 (DM1) with CUG repeats, Huntington's disease (HD) and spinocerebellar ataxia type 3 (SCA3) with CAG repeats, fragile X-associated tremor/ataxia syndrome (FXTAS) with CGG repeats, myotonic dystrophy type 2 (DM2) with CCUG repeats, amyotrophic lateral sclerosis/frontotemporal dementia (ALS/FTD) with GGGGCC repeats and spinocerebellar ataxia type 32 (SCA32) with GGCCUG. In this article, we summarize the results obtained with FISH to examine RNA nuclear inclusions. We provide a detailed protocol for detecting RNAs containing expanded CAG and CUG repeats in different cellular models, including fibroblasts, lymphoblasts, induced pluripotent stem cells and murine and human neuronal progenitors. We also present the results of the first single-molecule FISH application in a cellular model of polyglutamine disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  3. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Pausawasadi, Nonthalee [Department of Medicine, Siriraj Hospital, Mahidol University, Bangkok (Thailand); Soontornmanokul, Tanassanee; Rerknimitr, Rungsun [Department of Medicine, Chulalongkorn University, Bangkok (Thailand)

    2012-02-15

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  4. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    International Nuclear Information System (INIS)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee; Rerknimitr, Rungsun

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  5. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Science.gov (United States)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks. PMID:22563290

  6. A new self-expandable aortic valved stent deployed above native leaflets for aortic insufficiency: an in vitro study.

    Science.gov (United States)

    Huang, H; Zhou, Y; Shao, J; Cai, J; Mei, Y; Wang, Y

    2012-12-01

    The aim of this paper was to develop a new self-expandable aortic valved stent following the shape of the sinus of Valsalva, which can be deployed above native leaflets for aortic regurgitation, and study it's effect on coronary artery flow when orthotopic implantation in and above native leaflets. New self-expandable aortic valved stent consist of nitinol stent and bovine pericardium, and was designed following the shape of the sinus of Valsalva, the bovine pericardium was tailed as native leaflet. Thirty-six swine hearts were divided into three equal groups of twelve. In Group A (N.=12), the new self-expandable aortic valved stents deployed in native leaflets. In Group B (N.=12), the new self-expandable aortic valved stents deployed above native leaflets. In Group C (N.=12), the cylinder-like valved stents deployed only in native leaflets. The measurements of each coronary flow rate and endoscopic inspections were repeated post-implantation. In Group A and C, valve implantation in native leaflets resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after new self-expandable aortic valved stent placement. Endoscopic inspections showed that in group A and C the native leaflets sandwiched between valved stent and aortic wall, whereas, in group B the native leaflets were under the artificial leaflets. Two kinds of stents deployed in native leaflets affect left and right coronary flows significantly. No significant effect was found when the new self-expandable aortic valved stent deployed above native leaflets. This new self-expandable aortic valved stent can be deployed above the native leaflets, which avoids the obstruction of native leaflets on coronary flow.

  7. Endoscopy-guided balloon dilation of benign anastomotic strictures after radical gastrectomy for gastric cancer.

    Science.gov (United States)

    Lee, Hyun Jik; Park, Wan; Lee, Hyuk; Lee, Keun Ho; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan; Noh, Sung Hoon

    2014-07-01

    The aim of this study was to evaluate the outcome of endoscopic dilation for benign anastomotic stricture after radical gastrectomy in gastric cancer patients. Gastric cancer patients who underwent endoscopic balloon dilation for benign anastomosis stricture after radical gastrectomy during a 6-year period were reviewed retrospectively. Twenty-one patients developed benign strictures at the site of anastomosis. The majority of strictures occurred within 1 year after surgery (95.2%). The median duration to stenosis after surgery was 1.70 months (range, 0.17 to 23.97 months). The success rate of the first endoscopic dilation was 61.9%. Between the restenosis group (n=8) and the no restenosis group (n=13), there were no significant differences in the body mass index (22.82 kg/m(2) vs 22.46 kg/m(2)), interval to symptom onset (73.9 days vs 109.3 days), interval to treatment (84.6 days vs 115.6 days), maximal balloon diameter (14.12 mm vs 15.62 mm), number of balloon dilation sessions (1.75 vs 1.31), location of gastric cancer or type of surgery. One patient required surgery because of stricture refractory to repeated dilation. Endoscopic dilation is a highly effective treatment for benign anastomotic strictures after radical gastrectomy for gastric cancer and should be considered a primary intervention prior to proceeding with surgical revision.

  8. New developments in the clinical use of drug-coated balloon catheters in peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Naghi J

    2016-06-01

    Full Text Available Jesse Naghi, Ethan A Yalvac, Ali Pourdjabbar, Lawrence Ang, John Bahadorani, Ryan R Reeves, Ehtisham Mahmud, Mitul Patel Division of Cardiovascular Medicine, Sulpizio Cardiovascular Center, University of California, San Diego, CA, USA Abstract: Peripheral arterial disease (PAD involving the lower extremity is a major source of morbidity and mortality. Clinical manifestations of PAD span the spectrum from lifestyle limiting claudication to ulceration and gangrene leading to amputation. Advancements including balloon angioplasty, self-expanding stents, drug-eluting stents, and atherectomy have resulted in high technical success rates for endovascular therapy in patients with PAD. However, these advances have been limited by somewhat high rates of clinical restenosis and clinically driven target lesion revascularization. The recent introduction of drug-coated balloon technology shows promise in limiting neointimal hyperplasia induced by vascular injury after endovascular therapies. This review summarizes the contemporary clinical data in the emerging area of drug-coated balloons. Keywords: drug-coated balloons, endovascular, percutaneous transluminal angioplasty, paclitaxel, peripheral arterial disease

  9. Self-expanding/shrinking structures by 4D printing

    Science.gov (United States)

    Bodaghi, M.; Damanpack, A. R.; Liao, W. H.

    2016-10-01

    The aim of this paper is to create adaptive structures capable of self-expanding and self-shrinking by means of four-dimensional printing technology. An actuator unit is designed and fabricated directly by printing fibers of shape memory polymers (SMPs) in flexible beams with different arrangements. Experiments are conducted to determine thermo-mechanical material properties of the fabricated part revealing that the printing process introduced a strong anisotropy into the printed parts. The feasibility of the actuator unit with self-expanding and self-shrinking features is demonstrated experimentally. A phenomenological constitutive model together with analytical closed-form solutions are developed to replicate thermo-mechanical behaviors of SMPs. Governing equations of equilibrium are developed for printed structures based on the non-linear Green-Lagrange strain tensor and solved implementing a finite element method along with an iterative incremental Newton-Raphson scheme. The material-structural model is then applied to digitally design and print SMP adaptive lattices in planar and tubular shapes comprising a periodic arrangement of SMP actuator units that expand and then recover their original shape automatically. Numerical and experimental results reveal that the proposed planar lattice as meta-materials can be employed for plane actuators with self-expanding/shrinking features or as structural switches providing two different dynamic characteristics. It is also shown that the proposed tubular lattice with a self-expanding/shrinking mechanism can serve as tubular stents and grippers for bio-medical or piping applications.

  10. Self-Guided Field Explorations: Integrating Earth Science into Students' Lives

    Science.gov (United States)

    Kirkby, K. C.; Kirkby, S.

    2013-12-01

    Self-guided field explorations are a simple way to transform an earth science class into a more pedagogically effective experience. Previous experience demonstrated that self-guided student explorations of museum and aquarium exhibits were both extremely popular and remarkably effective. That success led our program to test an expansion of the concept to include self-guided student explorations in outdoor field settings. Preliminary assessment indicates these self-guided field explorations are nearly as popular with students as the museum and aquarium explorations and are as pedagogically effective. Student gains on post-instruction assessment match or exceed those seen in instructor-assisted, hands-on, small group laboratory activities and completely eclipse gains achieved by traditional lecture instruction. As importantly, self-guided field explorations provide a way to integrate field experiences into large enrollment courses where the sheer scale of class trips makes them logistically impossible. This expands course breadth, integrating new topics that could not be as effectively covered by the original class structure. Our introductory program assessed two models of self-guided field explorations. A walking/cycling exploration of the Saint Anthony Falls area, a mile from campus, focuses on the intersections of geological processes with human history. Students explore the geology behind the waterfalls' evolution as well as its subsequent social and economic impacts on human history. A second exploration focuses on the campus area geology, including its building stones as well as its landscape evolution. In both explorations, the goal was to integrate geology with the students' broader understanding of the world they live in. Although the explorations' creation requires a significant commitment, once developed, self-guided explorations are surprisingly low maintenance. These explorations provide a model of a simple, highly effective pedagogical tool that is

  11. Balloon catheter dilatation of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures.

  12. Balloon catheter dilatation of esophageal strictures

    International Nuclear Information System (INIS)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon

    1990-01-01

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures

  13. TU-AB-201-07: Image Guided Endorectal HDR Brachytherapy Using a Compliant Balloon Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, G; Goodman, K [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: High dose rate endorectal brachytherapy is an option to deliver a focal, high-dose radiotherapy to rectal tumors for patients undergoing non-operative management. We investigate a new multichannel, MR compatible applicator with a novel balloon-based design to provide improved treatment geometry. We report on the initial clinical experience using this applicator. Methods: Patients were enrolled on an IRB-approved, dose-escalation protocol evaluating the use of the anorectal (AR-1) applicator (Ancer Medical, Hialeah, FL), a multichannel applicator with two concentric balloons. The inner balloon supports 8 source lumens; the compliant outer balloon expands to separate the normal rectal wall and the source lumens, yet deforms around a firm, exophytic rectal mass, leading to dose escalation to tumor while sparing normal rectum. Under general anesthesia, gold fiducial markers were inserted above and below the tumor, and the AR applicator was placed in the rectum. MRI-based treatment plans were prepared to deliver 15 Gy in 3 weekly fractions to the target volume while sparing healthy rectal tissue, bladder, bowel and anal muscles. Prior to each treatment, CBCT/Fluoroscopy were used to place the applicator in the treatment position and confirm the treatment geometry using rigid registration of the CBCT and planning MRI. After registration of the applicator images, positioning was evaluated based on the match of the gold markers. Results: Highly conformal treatment plans were achieved. MR compatibility of the applicator enabled good tumor visualization. In spite of the non-rigid nature of the applicators and the fact that a new applicator was used at each treatment session, treatment geometry was reproducible to within 2.5 mm. Conclusions: This is the first report on using the AR applicator in patients. Highly conformal plans, confidence in MRI target delineation, in combination with reproducible treatment geometry provide encouraging feedback for continuation with

  14. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    Science.gov (United States)

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  15. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  16. Esophagorespiratory fistula: treatment with self-expanding covered stent

    International Nuclear Information System (INIS)

    Zang Jian; Dou Yongchong; Wang Zheng; Kong Jian

    2002-01-01

    Objective: To evaluate self-expanding covered stent in the management of esophagorespiratory fistula. Methods: A self-expanding esophageal covered stent was implanted under fluoroscopic guidance in 13 patients with esophagorespiratory fistula. In this series patients aged 31-73 years (60.2 years in average). All patients had a pre-procedure fast of 6-41 days (17.3 days in average), in which 12 patients had pulmonary infection. Results: All fistulas were excluded and swallowing function was restored. No stend-related complication was observed. Pulmonary infection was managed in 10 patients out of 13. The mean survived time was 33.3 wks (1-178 wks) in follow-up. Conclusion: Covered self-expanding stent implantation is a safe and effective treatment of ERF

  17. Biliary self-expandable metallic stent using single balloon enteroscopy assisted ERCP: overcoming limitations of current accessories

    Directory of Open Access Journals (Sweden)

    Rolando Pinho

    2013-10-01

    Full Text Available Device assisted enteroscopy (DAE techniques have been recently developed for the diagnosis and treatment of small bowel diseases. These techniques can also be used to perform endoscopic retrograde cholangiopancreatography (ERCP in patients with surgically altered anatomies. The main difficulties with DAE-ERCP are related to type of surgery, to the different dimensions and lack of frontal view of the enteroscope and to the resulting limitations with the use of standard accessories, resulting in the need of dedicated accessory devices. Although most ERCP techniques have been successfully performed with DAE-ERCP, biliary self-expandable metallic stents (SEMS have not yet been used, as dedicated biliary SEMS for the enteroscope are lacking. The authors present a case report showing a new method to place standard biliary trough-the-scope SEMS with DAE-ERCP, using a different technique of stent deployment.

  18. Base excision repair of chemotherapeutically-induced alkylated DNA damage predominantly causes contractions of expanded GAA repeats associated with Friedreich's ataxia.

    Directory of Open Access Journals (Sweden)

    Yanhao Lai

    Full Text Available Expansion of GAA·TTC repeats within the first intron of the frataxin gene is the cause of Friedreich's ataxia (FRDA, an autosomal recessive neurodegenerative disorder. However, no effective treatment for the disease has been developed as yet. In this study, we explored a possibility of shortening expanded GAA repeats associated with FRDA through chemotherapeutically-induced DNA base lesions and subsequent base excision repair (BER. We provide the first evidence that alkylated DNA damage induced by temozolomide, a chemotherapeutic DNA damaging agent can induce massive GAA repeat contractions/deletions, but only limited expansions in FRDA patient lymphoblasts. We showed that temozolomide-induced GAA repeat instability was mediated by BER. Further characterization of BER of an abasic site in the context of (GAA20 repeats indicates that the lesion mainly resulted in a large deletion of 8 repeats along with small expansions. This was because temozolomide-induced single-stranded breaks initially led to DNA slippage and the formation of a small GAA repeat loop in the upstream region of the damaged strand and a small TTC loop on the template strand. This allowed limited pol β DNA synthesis and the formation of a short 5'-GAA repeat flap that was cleaved by FEN1, thereby leading to small repeat expansions. At a later stage of BER, the small template loop expanded into a large template loop that resulted in the formation of a long 5'-GAA repeat flap. Pol β then performed limited DNA synthesis to bypass the loop, and FEN1 removed the long repeat flap ultimately causing a large repeat deletion. Our study indicates that chemotherapeutically-induced alkylated DNA damage can induce large contractions/deletions of expanded GAA repeats through BER in FRDA patient cells. This further suggests the potential of developing chemotherapeutic alkylating agents to shorten expanded GAA repeats for treatment of FRDA.

  19. Balloon dilatation for the treatment of stricture of gastrojejunostomy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yeon Hwa [Lee Rha Hospital, Chungju (Korea, Republic of); Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Han, Young Min; Chon, Su Bin; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul [Chonbuk National University College of Medicine, Chungju (Korea, Republic of)

    1993-07-15

    Enteroenteric anastomotic strictures of UGI tract are common and require treatment if significant obstruction occurs. We performed fluoroscopic guided balloon dilatation in 6 patients who had symptomatic stricture of gastrojejunostomy. The stricture was successfully resolved in 4 patients with benign stricture. But 2 patients with malignant stricture had recurrence of obstructive symptoms 2 weeks later, and they required a stent. Asymptomatic balloon rupture was seen in one patients, but other procedural complications did not occur. We found that fluoroscopic guided balloon dilatation is an effective and safe method in the treatment of anastomotic stricture of gastrojejunostomy. We also found transient effect in malignant gastrojejunal anastomotic strictures, which required an interventional procedure, such as placement of a stent.

  20. Comparison between double-balloon and single-balloon enteroscopy in therapeutic ERC after Roux-en-Y entero-enteric anastomosis.

    Science.gov (United States)

    Moreels, Tom G; Pelckmans, Paul A

    2010-09-16

    To compare the efficacy of double-balloon enteroscopy (DBE) and single-balloon enteroscopy (SBE) in therapeutic endoscopic retrograde cholangiography (ERC) in patients with Roux-en-Y entero-enteric anastomosis. Retrospective analysis of our patient cohort revealed 4 patients with enterobiliary anastomosis and Roux-en-Y entero-enteric anastomosis who underwent repeated ERC with DBE and SBE because of recurrent cholangitis. A total of 38 endoscopic retrograde cholangiopancreatography procedures were performed in 25 patients with Roux-en-Y entero-enteric anastomosis. DBE was used in 29 procedures and SBE in 9. The 4 patients who underwent repeated ERC with DBE and SBE suffered from recurrent cholangitis due to stenosis of the enterobiliary anastomosis. ERC was performed repeatedly to achieve balloon dilation with/without biliary stone extraction and multiple stent placement at the level of the enterobiliary anastomosis. In all 4 patients DBE and SBE were equally successful. Compared to DBE, SBE was equally effective in passing the Roux-en-Y entero-enteric anastomosis, reaching the enterobiliary anastomosis and performing therapeutic ERC. This retrospective comparison shows that DBE and SBE are equally successful in the performance of therapeutic ERC at the level of the enterobiliary anastomosis after Roux-en-Y entero-enteric anastomosis.

  1. Innovations in Balloon Catheter Technology in Rhinology.

    Science.gov (United States)

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Sequestration of DROSHA and DGCR8 by Expanded CGG RNA Repeats Alters MicroRNA Processing in Fragile X-Associated Tremor/Ataxia Syndrome

    Directory of Open Access Journals (Sweden)

    Chantal Sellier

    2013-03-01

    Full Text Available Fragile X-associated tremor/ataxia syndrome (FXTAS is an inherited neurodegenerative disorder caused by the expansion of 55–200 CGG repeats in the 5′ UTR of FMR1. These expanded CGG repeats are transcribed and accumulate in nuclear RNA aggregates that sequester one or more RNA-binding proteins, thus impairing their functions. Here, we have identified that the double-stranded RNA-binding protein DGCR8 binds to expanded CGG repeats, resulting in the partial sequestration of DGCR8 and its partner, DROSHA, within CGG RNA aggregates. Consequently, the processing of microRNAs (miRNAs is reduced, resulting in decreased levels of mature miRNAs in neuronal cells expressing expanded CGG repeats and in brain tissue from patients with FXTAS. Finally, overexpression of DGCR8 rescues the neuronal cell death induced by expression of expanded CGG repeats. These results support a model in which a human neurodegenerative disease originates from the alteration, in trans, of the miRNA-processing machinery.

  3. Expanding Sex-Role Definitions by Self-Discovery.

    Science.gov (United States)

    Kahn, Sharon E.; Greenberg, Leslie S.

    1980-01-01

    Counselors who stimulate client self-discovery may help these clients experience undeveloped parts of themselves and expand their definitions of themselves and their sex-role possibilities. Stimulation methods actively involve clients in the exploration of sex-role concerns to change restrictive self-concepts. (Author)

  4. Self - congruity Influence on Tourist Behavior: Repeat Visitors versus Non - Visitors and First - Time Visitors

    Directory of Open Access Journals (Sweden)

    Mithat Üner

    2013-12-01

    Full Text Available This study investigates the role of prior experience on the impact of actual self and ideal self-congruity on tourists’ intention to visit Turkey for leisure purposes. The study draws from an empirical study with 648 subjects conducted in cooperation with the Turkish Ministry of Culture and Tourism. Results suggest that the effect of actual self-congruity on intention to visit differs according to different levels of tourist experience. While self-congruity has a positive effect on intenti on to visit for the non-visitors and first-time visitors --implying that the relationship between self-congruity and intention does not vary between non-visitors and first-time visitors --this effect loses its significance for repeat visitors. These findings partially support the previous proposed moderating role of prior experience on the impact of self congruity on intention to visit a destination and expand the discussion on this topic raising new questions

  5. Self-expandable Metal Stent Placement Combining Double Balloon Endoscopy with a Percutaneous Approach in a Roux-en-Y Hepaticojejunostomy

    NARCIS (Netherlands)

    Koornstra, Jan J.; Alkefaji, Heyder

    The use of the double balloon endoscope for ERCP in patients with surgically altered anatomy has shown to be safe and feasible. This technique permits a variety of diagnostic and therapeutic possibilities. A case is presented of a 38-year old male, admitted with jaundice, 8 months after surgery for

  6. Current status of endoscopic balloon dilation for Crohn's disease

    Directory of Open Access Journals (Sweden)

    Fumihito Hirai

    2017-04-01

    Full Text Available The therapeutic target in Crohn's disease (CD has been raised to the achievement of mucosal healing. Although effective treatments that target cytokines and other molecules has been widely used for CD, intestinal strictures are still a major cause of surgery. Endoscopic balloon dilation (EBD is known to be an effective and safe intervention for intestinal strictures in CD. Since frequent intestinal resection often results in short bowel syndrome and can decrease the quality of life, EBD can help avoid surgery. EBD with a conventional colonoscope for Crohn's strictures of the colon and ileo-colonic anastomosis has established efficacy and safety. In addition, EBD using balloon-assisted enteroscopy has recently been applied for small bowel Crohn's strictures. Although the evidence is not strong, EBD may become an alternative to surgery in small bowel strictures in CD. EBD and other new methods such as self-expanding stent implantation for Crohn's strictures may be useful and safe; however, it is important to address several issues regarding these interventions and to establish a protocol for combined therapies.

  7. Functional Self-Expandable Metal Stents in Biliary Obstruction

    Science.gov (United States)

    Kwon, Chang-Il; Ko, Kwang Hyun; Hahm, Ki Baik

    2013-01-01

    Biliary stents are widely used not only for palliative treatment of malignant biliary obstruction but also for benign biliary diseases. Each plastic stent or self-expandable metal stent (SEMS) has its own advantages, and a proper stent should be selected carefully for individual condition. To compensate and overcome several drawbacks of SEMS, functional self-expandable metal stent (FSEMS) has been developed with much progress so far. This article looks into the outcomes and defects of each stent type for benign biliary stricture and describes newly introduced FSEMSs according to their functional categories. PMID:24143314

  8. Expand your English a guide to improving your academic vocabulary

    CERN Document Server

    Hart, Steve

    2018-01-01

    Writing academic prose in English is especially difficult for non-native speakers, largely because the standard vocabulary used in this genre can be quite different from colloquial English. Expand Your English: A Guide to Improving Your Academic Vocabulary is a unique and invaluable guide that will enable the reader to overcome this hurdle. It will become the favourite go-to reference book for both beginners and for intermediate learners struggling with the complexities of English-language academic writing. Steve Hart covers 1,000 vocabulary items that are essential for good academic writing. The first section describes 200 key terms in detail, grouping them into logical sets of 10. Through careful repetition, the reader will find it easy to retain, retrieve, and reuse these essential phrases. The second section explains a further 800 terms, grouping them according to function, meaning, and the areas of an essay where they are likely to be used. The expansive scope of Expand Your English gives non-native spea...

  9. Guided self-organization inception

    CERN Document Server

    2014-01-01

    Is it possible to guide the process of self-organisation towards specific patterns and outcomes?  Wouldn’t this be self-contradictory?   After all, a self-organising process assumes a transition into a more organised form, or towards a more structured functionality, in the absence of centralised control.  Then how can we place the guiding elements so that they do not override rich choices potentially discoverable by an uncontrolled process?  This book presents different approaches to resolving this paradox.  In doing so, the presented studies address a broad range of phenomena, ranging from autopoietic systems to morphological computation, and from small-world networks to information cascades in swarms.  A large variety of methods is employed, from spontaneous symmetry breaking to information dynamics to evolutionary algorithms, creating a rich spectrum reflecting this emerging field. Demonstrating several foundational theories and frameworks, as well as innovative practical implementations, Guided S...

  10. Upper gastrointestinal strictures: The results of balloon dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Woo; Lim, Hyo Keun; Choo, In Wook; Bae, Sang Hoon; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of); Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Balloon catheter dilatation of upper gastrointestinal strictures is an accepted mode of therapy. The authors report the balloon dilatation in 11 consecutive patients. The lesions treated included 10 benign strictures, and 1 esophageal cancer. Esophageal balloon were ranged from 2 mm in diameter, 4 cm in length, to 30 mm in diameter, 8 cm in length. Inflation was held for from 30 to 60 seconds and then repeated two or three times during each session. The balloons were inflated to pressure of from 2 to 12 atmospheres. There were from 1 to 13 dilatations. Two esophageal perforations were occurred in one esophagitis patient and other lye stricture patient. Two perforations were not required any surgical repair. All dilatation were performed without anesthesia. All strictures were responded immediately to dilatation. Prolonged course of treatment were needed with chronic severe esophagitis, lye stricture, gastrojejunostomy with chemotherapy, as a result, all patients, except esophageal cancer, could take regular diet after balloon catheter dilatation. Balloon catheter dilatation of upper gastrointestinal stenosis was effective and safe. It should be considered before other methods of treatment applicable.

  11. Balloon dilatation of tuberculous bronchial stenosis: immediate and long term effect

    International Nuclear Information System (INIS)

    Lee, Sang Yoon; Kwak, Byung Kook; Kang, Ho Yeong; Kim, Tae Hoon; Kim, Soo Rhan; Park, Hyun Sun; Lee, Shin Hyung; Lee, Chang Joon

    1997-01-01

    To evaluate the long-term immediate effects of balloon dilatation of the tuberculous bronchial stenosis. Twenty-three women with tuberculous bronchial stenosis (19, left main bronchus ; 4, right main bronchus) underwent balloon dilatation (13 bronchoscopically guided ; 10 fluoroscopically guided). Immediate (n=23) and long-term follow-up (mean, 17.2 months; range, 1month-6years 3months ; n=20) assessments focused on changes in the results of the pulmonary function test (PFT). An increase in FVC or FEVI of more than 10% after the procedure was considered effective. In all patients, any complications were evaluated. Balloon dilatation was effective at immediate follow-up in 69.5% of patients(16/23) and in 75.0%(15/20) at long-term follow-up. Bronchoscopically and fluoroscopically-guided balloon dilatation proved effective in 61.5%(8/13) and 80.0% of patients(8/10) on immediate follow-up respectively, but in 90.0%(9/10) and 60.0%(6/10) on long term follow-up respectively. Balloon dilatation was effective in the active(n 10) and inactive(n = 13) stage of tuberculous bronchitis in 80.0%(8/10) and 61.5% of cases(8/13) on immediate follow-up respectively, but in 66.6%(6/9) and 81.8%(9/11) on long term follow-up study, respectively. On immediate follow-up, balloon dilatation of tubular bronchial stenosis was more effective in the active than in the inactive stage, but on long-term follow-up was less effective ; long-term improvement in the inactive stage was, however, well-maintained

  12. Preservice science teachers' experiences with repeated, guided inquiry

    Science.gov (United States)

    Slack, Amy B.

    The purpose of this study was to examine preservice science teachers' experiences with repeated scientific inquiry (SI) activities. The National Science Education Standards (National Research Council, 1996) stress students should understand and possess the abilities to do SI. For students to meet these standards, science teachers must understand and be able to perform SI; however, previous research demonstrated that many teachers have naive understandings in this area. Teacher preparation programs provide an opportunity to facilitate the development of inquiry understandings and abilities. In this study, preservice science teachers had experiences with two inquiry activities that were repeated three times each. The research questions for this study were (a) How do preservice science teachers' describe their experiences with repeated, guided inquiry activities? (b) What are preservice science teachers' understandings and abilities of SI? This study was conducted at a large, urban university in the southeastern United States. The 5 participants had bachelor's degrees in science and were enrolled in a graduate science education methods course. The researcher was one of the course instructors but did not lead the activities. Case study methodology was used. Data was collected from a demographic survey, an open-ended questionnaire with follow-up interviews, the researcher's observations, participants' lab notes, personal interviews, and participants' journals. Data were coded and analyzed through chronological data matrices to identify patterns in participants' experiences. The five domains identified in this study were understandings of SI, abilities to conduct SI, personal feelings about the experience, science content knowledge, and classroom implications. Through analysis of themes identified within each domain, the four conclusions made about these preservice teachers' experiences with SI were that the experience increased their abilities to conduct inquiry

  13. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka; Konishi, Takahiro; Uchikawa, Yoko [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan); Fukuda, Kuniaki [University of Tsukuba Hospital, Department of Gastroenterology (Japan); Minami, Manabu [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-04-15

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

  14. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    Science.gov (United States)

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  15. Severe Sunburn After a Hot Air Balloon Ride: A Case Report and Literature Review.

    Science.gov (United States)

    Ozturk, Sinan; Karagoz, Huseyin

    2015-01-01

    Hot air balloon tours are very popular among travelers worldwide. Preventable burn injuries associated with hot air balloon rides have been reported during crashes into power lines, in propane burner explosions, and following contact with the propane burner tanks. We present a case of severe repeated sunburn, which poses another risk of preventable injury during hot air balloon rides, and briefly discuss the injury epidemiology of hot air balloon rides. © 2015 International Society of Travel Medicine.

  16. Broncho-vascular fistulas from self-expanding metallic stents: A retrospective case review

    Directory of Open Access Journals (Sweden)

    Chirag Choudhary

    2013-01-01

    Full Text Available To highlight a potentially fatal complication of broncho-vascular fistula arising from the self expanding metallic stent (SEMS placement. We retrospectively analyzed five patients with benign and malignant airway diseases, who developed tracheo/broncho-vascular fistulas following SEMS placement in our tertiary care setting. All patients received either Wallstent or Ultraflex® stent (Boston Scientific, Natick, MA between 1999 and 2007. All patients had received adjunct therapy such as balloon bronchoplasty, laser therapy or electrocautery. Most patients presented with massive hemoptysis. A total of 483 SEMS were placed during this period. SEMS placement can be complicated by Broncho-vascular fistula formation. True incidence and precise time interval between the insertion of stent and onset of this complication is unknown. Additional therapeutic modalities to maintain stent patency may enhance the risk of fistula formation. SEMS should only be used in a select sub-group of patients, after exhaustive evaluation of other treatment options. These cases provide evidence that broncho-vascular fistulas can develop at any time following SEMS placement, suggesting the need for a more cautious approach, especially while using them for a long term management. In benign airway disease, the stent should be removed as soon as healing has taken place.

  17. In-vitro release of anti-proliferative paclitaxel from novel balloon-expandable polycaprolactone stents

    International Nuclear Information System (INIS)

    Liu, Shih-Jung; Hsiao, Chao-Ying; Chen, Jan-Kan; Liu, Kuo-Sheng; Lee, Cheng-Hung

    2011-01-01

    This report investigated the in-vitro release characteristics of paclitaxel from novel balloon-expandable polycaprolactone stents. Polycaprolactone stents were first manufactured by a lab-made micro-injection molding machine. Paclitaxel and polylactide-polyglycolide (PLGA) copolymer were dissolved in acetonitrile and were coated onto the surface of the stents by a spray coating device, which was designed and built especially for this study. An elution method was utilized to characterize the in-vitro release characteristics of paclitaxel. The high performance liquid chromatography (HPLC) analysis showed that biodegradable stents could provide sustained release of paclitaxel for more than 70 days. Various process parameters that controlled the release rate of paclitaxel were studied. The experimental results suggested that the total period of drug release could be prolonged by adopting 75:25 PLGA copolymers, employing multi-layer coatings, and increasing the drug loading. In addition, the effectiveness of eluted paclitaxel on cell behavior was examined. The results showed that the eluted drug could effectively inhibit the proliferation of smooth muscle cells. - Research Highlights: → We investigate the in-vitro release characteristics of paclitaxel from polycaprolactone stents. → Biodegradable stents provide sustained release of paclitaxel for more than 70 days. → The eluted drug effectively inhibits the proliferation of smooth muscle cells.

  18. Esophageal carcinoma treatment with self-expanding covered stent implanted in esophagus

    International Nuclear Information System (INIS)

    Liu Mingguo; Ji Yan; He Nengwei

    2006-01-01

    Objective: To investigate the clinical significance of the treatment to esophageal cancer by self- expanding covered stent implanted into esophagus. Methods: Under fluoroscopic guidance and with guidance wire , 20 self-expanding covered stents were implanted into stenotic part of esophagus to recanalize the esophagus, then follow up to observe the clinical symptom improved. Results: Technical success was obtained 20 cases without any complication. Clinical symptom were improved in shot time. Conclusions: self-expanding covered stent is implanted in stenotic part of esophageal carcinoma to treat esophageal stenosis and enable to improved clinical symptom in shot time, if combined with transcatheter arterial infusion and embolization, Radiotherapy, Chinese medical treatment, it enable to lengthen life time remarkably. (authors)

  19. Guided self-help concreteness training as an intervention for major depression in primary care: a Phase II randomized controlled trial

    DEFF Research Database (Denmark)

    Watkins, E R; Taylor, R S; Baeyens, C

    2012-01-01

    major depression in primary care, although the effect was not significantly different from an existing active treatment (RT) matched for structural and common factors. Because of its relative brevity and distinct format, it may have value as an additional innovative approach to increase......Background The development of widely accessible, effective psychological interventions for depression is a priority. This randomized trial provides the first controlled data on an innovative cognitive bias modification (CBM) training guided self-help intervention for depression. Method One hundred...... and twenty-one consecutively recruited participants meeting criteria for current major depression were randomly allocated to treatment as usual (TAU) or to TAU plus concreteness training (CNT) guided self-help or to TAU plus relaxation training (RT) guided self-help. CNT involved repeated practice at mental...

  20. Stent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era

    Directory of Open Access Journals (Sweden)

    Mehrdad Taherioun

    2014-01-01

    Full Text Available BACKGROUND: Stent underexpansion is the most powerful predictor of long-term stent patency and clinical outcome. The purpose of this study was to evaluate the incidence and predictors of stent underexpansion despite adjunctive post-dilatation with non-compliant balloon. METHODS: After elective coronary stent implantation and adjunctive post-dilatation with non-compliant balloon and optimal angiographic result confirmed by the operator, intravascular ultrasound (IVUS was performed for all the treated lesions. If the treated lesions fulfilled the IVUS criteria, they are considered as the optimal stent group; if not, they are considered as the suboptimal group. RESULTS: From 50 patients enrolled in this study 39 (78% had optimal stent deployment and 11 (22% had suboptimal stent deployment. In the suboptimal group 7 (14% had underexpansion, 2 (4% malposition, and 2 (4% had asymmetry. There were no stent edge dissections detected by IVUS. We did not find any correlation between lesion calcification, ostial lesions, stent length, and stent underexpansion. Stent diameter ≤ 2.75 mm had a strong correlation with stent underexpansion. CONCLUSION: Despite adjunctive post-dilatation with noncompliant balloon, using a relatively small stent diameter was a strong predictor for underexpansion. IVUS guided percutaneous coronary intervention (PCI may be considered for drug eluting stent (DES implantation in relatively small vessels.   Keywords: Stent, Percutaneous Coronary Intervention, Ultrasound, Post-dilatation 

  1. Ballooning modes or Fourier modes in a toroidal plasma?

    International Nuclear Information System (INIS)

    Connor, J.W.; Taylor, J.B.

    1987-01-01

    The relationship between two different descriptions of eigenmodes in a torus is investigated. In one the eigenmodes are similar to Fourier modes in a cylinder and are highly localized near a particular rational surface. In the other they are the so-called ballooning modes that extend over many rational surfaces. Using a model that represents both drift waves and resistive interchanges the transition from one of these structures to the other is investigated. In this simplified model the transition depends on a single parameter which embodies the competition between toroidal coupling of Fourier modes (which enhances ballooning) and variation in frequency of Fourier modes from one rational surface to another (which diminishes ballooning). As the coupling is increased each Fourier mode acquires a sideband on an adjacent rational surface and these sidebands then expand across the radius to form the extended mode described by the conventional ballooning mode approximation. This analysis shows that the ballooning approximation is appropriate for drift waves in a tokamak but not for resistive interchanges in a pinch. In the latter the conventional ballooning effect is negligible but they may nevertheless show a ballooning feature. This is localized near the same rational surface as the primary Fourier mode and so does not lead to a radially extended structure

  2. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  3. Predictors for outcome of failure of balloon dilatation in patients with achalasia

    NARCIS (Netherlands)

    J. Alderliesten (Joyce); J.M. Conchillo; I. Leeuwenburgh (Ivonne); E.W. Steyerberg (Ewout); E.J. Kuipers (Ernst)

    2011-01-01

    textabstractBackground: Pneumatic balloon dilatation (PD) is a regular treatment modality for achalasia. The reported success rates of PD vary. Recurrent symptoms often require repeated PD or surgery. Objective: To identify predicting factors for symptom recurrence requiring repeated treatment.

  4. A Simple, High-Throughput Assay for Fragile X Expanded Alleles Using Triple Repeat Primed PCR and Capillary Electrophoresis

    Science.gov (United States)

    Lyon, Elaine; Laver, Thomas; Yu, Ping; Jama, Mohamed; Young, Keith; Zoccoli, Michael; Marlowe, Natalia

    2010-01-01

    Population screening has been proposed for Fragile X syndrome to identify premutation carrier females and affected newborns. We developed a PCR-based assay capable of quickly detecting the presence or absence of an expanded FMR1 allele with high sensitivity and specificity. This assay combines a triplet repeat primed PCR with high-throughput automated capillary electrophoresis. We evaluated assay performance using archived samples sent for Fragile X diagnostic testing representing a range of Fragile X CGG-repeat expansions. Two hundred five previously genotyped samples were tested with the new assay. Data were analyzed for the presence of a trinucleotide “ladder” extending beyond 55 repeats, which was set as a cut-off to identify expanded FMR1 alleles. We identified expanded FMR1 alleles in 132 samples (59 premutation, 71 full mutation, 2 mosaics) and normal FMR1 alleles in 73 samples. We found 100% concordance with previous results from PCR and Southern blot analyses. In addition, we show feasibility of using this assay with DNA extracted from dried-blood spots. Using a single PCR combined with high-throughput fragment analysis on the automated capillary electrophoresis instrument, we developed a rapid and reproducible PCR-based laboratory assay that meets many of the requirements for a first-tier test for population screening. PMID:20431035

  5. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  6. Palliative metallic stent placement for managing esophageal cancer of the aging

    International Nuclear Information System (INIS)

    Li Qnqi; Yin Huabin; Yue Wei; Ji Chengzhou; Yang Yufeng

    2000-01-01

    Objective: To evaluate the effectiveness of self-expanding metallic stent in the treatment of the old patients with malignant esophageal stricture. Methods: 32 old patients with malignant esophageal stricture were treated with covered self-expandable metallic stents, 32 stents were placed by X-TV guiding, without pre-dilatation of the stenosis by balloon catheter. Results: All 32 stents were successfully placed, the successful rate was 100%. All of the patients obtained the improvement of the food intake ability. No fatal stent-related complications occurred. The average survival time was 6.5 months. Conclusions: The covered self-expandable metallic stent is effective in the palliative management of malignant esophageal stricture of the aging

  7. Fluorescence Lyman-Alpha Stratospheric Hygrometer (FLASH): application on meteorological balloons, long duration balloons and unmanned aerial vehicles.

    Science.gov (United States)

    Lykov, Alexey; Khaykin, Sergey; Yushkov, Vladimir; Efremov, Denis; Formanyuk, Ivan; Astakhov, Valeriy

    hygrometer was installed at the nose of a small GPS-controlled glider, which was lifted by a meteorological balloon into the stratosphere and released by a remote command. GPS-based flight control guides and lands the UAV at the launch point thereby allowing multiple usage of its payload. Another sounding platform allowing for multiple usage of the FLASH instrument is a GPS-guided paraglide. The results of measurements acquired in the test flights using different types of balloon-lifted UAVs are presented.

  8. Subclinical leaflet thickening and stent frame geometry in self-expanding transcatheter heart valves

    DEFF Research Database (Denmark)

    Fuchs, Andreas; De Backer, Ole; Brooks, Matthew

    2017-01-01

    AIMS: This study aimed to assess the potential relationship between subclinical leaflet thickening and stent frame geometry in patients who underwent aortic valve replacement with a self-expanding transcatheter heart valve (THV). METHODS AND RESULTS: Seventy-five patients with a self-expanding THV....... CONCLUSIONS: Regional THV stent frame underexpansion is associated with an increased risk of leaflet thickening. Post-dilatation of self-expanding THV as well as a supra-annular valve position seem to reduce the occurrence of this phenomenon....

  9. "The devil's in the detail": Release of an expanded, enhanced and dynamically revised forensic STR Sequence Guide.

    Science.gov (United States)

    Phillips, C; Gettings, K Butler; King, J L; Ballard, D; Bodner, M; Borsuk, L; Parson, W

    2018-05-01

    The STR sequence template file published in 2016 as part of the considerations from the DNA Commission of the International Society for Forensic Genetics on minimal STR sequence nomenclature requirements, has been comprehensively revised and audited using the latest GRCh38 genome assembly. The list of forensic STRs characterized was expanded by including supplementary autosomal, X- and Y-chromosome microsatellites in less common use for routine DNA profiling, but some likely to be adopted in future massively parallel sequencing (MPS) STR panels. We outline several aspects of sequence alignment and annotation that required care and attention to detail when comparing sequences to GRCh37 and GRCh38 assemblies, as well as the necessary matching of MPS-based allele descriptions to previously established repeat region structures described in initial sequencing studies of the less well known forensic STRs. The revised sequence guide is now available in a dynamically updated FTP format from the STRidER website with a date-stamped change log to allow users to explore their own MPS data with the most up-to-date forensic STR sequence information compiled in a simple guide. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Endoscope-guided pneumatic dilation for treatment of esophageal achalasia

    Science.gov (United States)

    Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin

    2010-01-01

    Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764

  11. Esophagojejunal anastomotic leak managed with self expandable metallic stent

    Directory of Open Access Journals (Sweden)

    Arvind Madurandagam Annapillai

    2013-01-01

    Full Text Available Esophagealjejunal anastomotic leak after gastrectomy is a serious surgical emergency with high mortality. This report describes a 57-year-old male with esophagojejunal anastomotic leak following total gastrectomy for gastric cancer and was managed successfully with self-expandable metallic stent. To our knowledge this is the first such report from India. This case report highlights the need of interdisciplinary coordination in managing this difficult clinical situation. Endotherapy with self-expandable metallic stent (SEM provided twin benefits of improving respiratory embarrassment and the joy of eating. Therapy of such difficult cases must be individualized; however, and SEM stent usage is a viable option

  12. Comparison of covered and uncovered self-expandable stents in the treatment of malignant biliary obstruction.

    Science.gov (United States)

    Flores Carmona, Diana Yamel; Alonso Lárraga, Juan Octavio; Hernández Guerrero, Angélica; Ramírez Solís, Mauro Eduardo

    2016-05-01

    Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable and uncovered self-expandable metallic stents in the palliative treatment of malignant biliary obstruction. Sixty eight patients with malignant obstructive jaundice secondary to pancreatobiliary or metastatic disease not amenable to surgery were retrospectively included. Two groups were created: group A (covered self-expandable metallic stents) (n = 22) and group B (uncovered self-expandable metallic stents) (n = 46). Serum total bilirubin, direct bilirubin, alkaline phosphatase and gamma glutamyl transferase levels decreased in both groups and no statistically significant difference was detected (p = 0.800, p = 0.190, p = 0.743, p = 0.521). Migration was greater with covered stents but it was not statistically significant either (p = 0.101). Obstruction was greater in the group with uncovered stents but it was not statistically significant either (p = 0.476). There are no differences when using covered self-expandable stents or uncovered self-expandable stents in terms of technical and clinical success or complications in the palliative treatment of malignant obstructive jaundice.

  13. Predictors for repeat self-harm and suicide among older people within 12 months of a self-harm presentation.

    Science.gov (United States)

    Cheung, Gary; Foster, Gisele; de Beer, Wayne; Gee, Susan; Hawkes, Tracey; Rimkeit, Sally; Tan, Yu Mwee; Merry, Sally; Sundram, Frederick

    2017-08-01

    A past history of self-harm is a significant risk factor for suicide in older people. The aims of this study are to (i) characterize older people who present with self-harm to emergency departments (EDs); and (ii) determine the predictors for repeat self-harm and suicide. Demographic and clinical data were retrospectively collected on older people (age 65+ years), who presented to seven EDs in New Zealand following an episode of self-harm between 1st July 2010 and 30th June 2013. In addition, 12-month follow-up information on repeat self-harm and suicide was collected. The sample included 339 older people (55.2% female) with an age range of 65-96 years (mean age = 75.0; SD = 7.6). Overdose (68.7%) was the most common method of self-harm. 76.4% of the self-harm cases were classified as suicide attempts. Perceived physical illness (47.8%) and family discord (34.5%) were the most common stressors. 12.7% of older people repeated self-harm and 2.1% died by suicide within 12 months. Older people who had a positive blood alcohol reading (OR = 3.87, 95% Cl = 1.35-11.12, p = 0.012) and were already with mental health services at the index self-harm (OR = 2.73, 95% Cl = 1.20-6.25, p = 0.047) were more likely to repeat self-harm/suicide within 12 months. Older people who self-harm are at very high risk of repeat self-harm and suicide. Screening and assessment for alcohol use disorders should be routinely performed following a self-harm presentation, along with providing structured psychological treatment as an adjunct to pharmacological treatment for depression and interventions to improve the person's resilience resources.

  14. Guided Reading and Motivation

    Science.gov (United States)

    Hauptman, Allyson L.

    2012-01-01

    The purpose of this study was to determine the relationship between Guided Reading and student motivation to read across fourth, fifth, and sixth grades. The study defined literacy motivation as: (a) task value; (b) self-perceived competence; (c) students' perceptions of the Guided Reading format. Factor analysis and repeated measures ANOVAs were…

  15. Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2012-01-01

    Background. Self-expanding metal stents can alleviate malignant colonic obstruction in incurable patients and avoid palliative stoma surgery. Objective. Evaluate stent effectiveness and safety on palliation of patients with malignant colorectal strictures. Design. Two prospective, one Spanish....... Interventions(s). Self-expanding metal stent placement. Main Outcome Measures. Procedural success, clinical success, and safety. Results. Procedural success was 98.4% (251). Clinical success rates were 87.8% at 30 days, 89.7% at 3 months, 92.8% at 6 months, and 96% at 12 months. Overall perforation rate was 5...... for patients with malignant colonic obstruction should be self-expanding metal stent placement due to high rates of technical success and efficacy in symptom palliation and few complications....

  16. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De

    1990-01-01

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  17. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  18. Arterial stenting with self-expandable and balloon-expandable endoprostheses

    NARCIS (Netherlands)

    W.J. van der Giessen (Wim); P.W.J.C. Serruys (Patrick); L.J. van Woerkens (L.); K.J. Beatt (Kevin); W.J. Visser (Willy); J.F. Jongkind; R.H. van Bremen (Robert); E. Ridderhof; H. van Loon (Heleen); L.K. Soei (Lou Kie); H.M.M. van Beusekom (Heleen); P.D. Verdouw (Pieter)

    1990-01-01

    textabstractCoronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several

  19. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  20. Treatment of Benign Tracheal Stenosis Utilizing Self-Expanding Nitinol Stents

    International Nuclear Information System (INIS)

    Sesterhenn, Andreas M.; Wagner, Hans-Joachim; Alfke, Heiko; Werner, Jochen A.; Lippert, Burkard M.

    2004-01-01

    We assessed the results of self-expanding metallic stent insertion into benign proximal tracheal stenosis in patients not appropriate or unfit for surgical repair. Proximal benign tracheal stenoses had occurred in 11 patients (7 men, 4 women, mean age 68.8 years) after long-time intubation (n = 6), tracheostomy (n = 4), or chondropathia (n = 1). Fourteen self-expanding nitinol stents were placed in the patients under general anesthesia with endoscopical and fluoroscopical guidance. Stent insertion was successful in all cases and led to immediate relief of the morphological and functional airway obstruction. No immediate complications were noted. During the mean follow-up period of 67.5 weeks we observed one recurrent dyspnea 3 months after implantation and granuloma formation at the stent insertion site in another patient. Both complications were successfully treated with additional stent insertion in one case and laser resection of granulomas in the other. Self-expanding nitinol stents should be considered for the treatment of benign proximal tracheal obstruction in selected patients for whom surgical repair is contraindicated

  1. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    Science.gov (United States)

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Placement of a covered self-expandable nitinol stent for bile duct stricture that caused by ischemic injury after transcatheter arterial chemoembolization in a patient with hepatocellular carcinoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Kweon; Seo, Tae Seok; Cha, In Ho; Huh, Sik; Byun, Kwan Soo [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2008-10-15

    The authors report here on a case of focal stricture in the common hepatic duct that was caused by ischemic bile duct injury after repeat TACE procedures for hepatocellular carcinoma, and the patient was successfully treated with a covered self-expandable nitinol stent.

  3. Localization of a Portion of an Endorectal Balloon for Prostate Image-Guided Radiation Therapy Using Cone-Beam Tomosynthesis: A Feasibility Study

    International Nuclear Information System (INIS)

    Ng, Sook Kien; Zygmanski, Piotr; Lyatskaya, Yulia; D’Amico, Anthony V.; Cormack, Robert A.

    2012-01-01

    Purpose: To assess the feasibility of using cone-beam tomosynthesis (CBTS) to localize the air–tissue interface for the application of prostate image-guided radiation therapy using an endorectal balloon for immobilization and localization. Methods and Materials: A Feldkamp-David-Kress-based CBTS reconstruction was applied to selected sets of cone-beam computed tomography (CBCT) projection data to simulate volumetric imaging achievable from tomosynthesis for a limited range of scan angles. Projection data were calculated from planning CT images of 10 prostate cancer patients treated with an endorectal balloon, as were experimental CBCT projections for a pelvic phantom in two patients. More than 50 points at the air–tissue interface were objectively identified by an intensity-based interface-finding algorithm. Using three-dimensional point sets extracted from CBTS images compared with points extracted from corresponding CBCT images, the relative shift resulting from a reduced scan angle was determined. Because the CBCT and CBTS images were generated from the same projection data set, shift identified was presumed to be due to distortions introduced by the tomosynthesis technique. Results: Scans of ≥60° were shown to be able to localize an air–tissue interface near the isocenter with accuracy on the order of a millimeter. The accuracy was quantified in terms of the mean discrepancy as a function of reconstruction angle. Conclusion: This work provides an understanding of the effect of scan angle used in localization of a portion of an endorectal balloon by means of CBTS. CBTS with relatively small scan angles is capable of accurately localizing an extended interface near the isocenter and may provide clinically relevant measurements to guide IGRT treatments while reducing imaging radiation to the patient.

  4. Localization of a Portion of an Endorectal Balloon for Prostate Image-Guided Radiation Therapy Using Cone-Beam Tomosynthesis: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Sook Kien, E-mail: Sook_Ng@dfci.harvard.edu [Department of Radiation Oncology, Brigham and Women' s Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiation Oncology, Mannheim Medical Centre, University of Heidelberg, Mannheim (Germany); Zygmanski, Piotr; Lyatskaya, Yulia; D' Amico, Anthony V.; Cormack, Robert A. [Department of Radiation Oncology, Brigham and Women' s Hospital and Harvard Medical School, Boston, MA (United States)

    2012-06-01

    Purpose: To assess the feasibility of using cone-beam tomosynthesis (CBTS) to localize the air-tissue interface for the application of prostate image-guided radiation therapy using an endorectal balloon for immobilization and localization. Methods and Materials: A Feldkamp-David-Kress-based CBTS reconstruction was applied to selected sets of cone-beam computed tomography (CBCT) projection data to simulate volumetric imaging achievable from tomosynthesis for a limited range of scan angles. Projection data were calculated from planning CT images of 10 prostate cancer patients treated with an endorectal balloon, as were experimental CBCT projections for a pelvic phantom in two patients. More than 50 points at the air-tissue interface were objectively identified by an intensity-based interface-finding algorithm. Using three-dimensional point sets extracted from CBTS images compared with points extracted from corresponding CBCT images, the relative shift resulting from a reduced scan angle was determined. Because the CBCT and CBTS images were generated from the same projection data set, shift identified was presumed to be due to distortions introduced by the tomosynthesis technique. Results: Scans of {>=}60 Degree-Sign were shown to be able to localize an air-tissue interface near the isocenter with accuracy on the order of a millimeter. The accuracy was quantified in terms of the mean discrepancy as a function of reconstruction angle. Conclusion: This work provides an understanding of the effect of scan angle used in localization of a portion of an endorectal balloon by means of CBTS. CBTS with relatively small scan angles is capable of accurately localizing an extended interface near the isocenter and may provide clinically relevant measurements to guide IGRT treatments while reducing imaging radiation to the patient.

  5. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    Science.gov (United States)

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  6. Reduction of prostate intrafraction motion using gas-release rectal balloons

    International Nuclear Information System (INIS)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy

    2012-01-01

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5Σ+ 0.7σ to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior–inferior (SI) and anterior–posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left–right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  7. Reduction of prostate intrafraction motion using gas-release rectal balloons

    Energy Technology Data Exchange (ETDEWEB)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy [Department of Radiation Oncology, University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States)

    2012-10-15

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  8. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases

    NARCIS (Netherlands)

    van Halsema, Emo E.; Wong Kee Song, Louis M.; Baron, Todd H.; Siersema, Peter D.; Vleggaar, Frank P.; Ginsberg, Gregory G.; Shah, Pari M.; Fleischer, David E.; Ratuapli, Shiva K.; Fockens, Paul; Dijkgraaf, Marcel G. W.; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E.

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six

  9. Embolization of carotid-cavernous fistula using a silicone balloon and a tracker-catheter system

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Cho, Kil Ho; Park, Bok Hwan

    1992-01-01

    With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in case of small fistula, pseudo aneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitation, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients (silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing

  10. Percutaneous treatment of adult isthmic aortic coarctation: acute and long-term clinical and imaging outcome with a self-expandable uncovered nitinol stent.

    Science.gov (United States)

    Kische, Stephan; D'Ancona, Giuseppe; Stoeckicht, Yannik; Ortak, Jasmin; Elsässer, Albrecht; Ince, Hüseyin

    2015-01-01

    To present perioperative and long-term results of percutaneous treatment of adult isthmic coarctation of the aorta by means of a self-expandable closed-web uncovered nitinol stent (Sinus-XL, Optimed, Esslingen, Germany). Preoperative, perioperative, and long-term clinical and computed tomographic angiography data were collected and analyzed prospectively. A total of 52 consecutive patients were treated with the Sinus-XL stent. Mean age was 36.6 (21-67) years, peak invasive trans-coarctation of the aorta gradient was 54.7 ± 9.9 mm Hg, and upper body hypertension unresponsive to medical treatment was present in all patients. Mean stent diameter and length were 24.2 mm (22-28 mm) and 70.4 mm (40-80 mm), respectively. Eight patients (15.4%) required coarctation of the aorta predilatation. All patients underwent poststent dilatation with a noncompliant balloon. Postoperative peak gradient (3.3 ± 2.5 mm Hg) was reduced significantly (P stent collapse and secondary migration and documented stability in aortic diameter (18.3 ± 2.7 mm). Thirty patients (57.7%) were completely weaned-off antihypertensive medications and their use dropped from 2.6 to 0.9 drugs/patient (P self-expandable uncovered stent is safe and durable. The peculiar stent design maintains adequate localized radial strength over time with minimal trauma on the adjacent aortic wall and negligible device-related complications. Blood pressure control optimization is immediate and persistent even at long-term follow-up. © 2015 American Heart Association, Inc.

  11. Self-Expandable Metallic Stent Placement for the Palliation of Esophageal Cancer.

    Science.gov (United States)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho Young; Kim, Pyeong Hwa; Park, Jung Hoon

    2017-07-01

    Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future. © 2017 The Korean Academy of Medical Sciences.

  12. The technique study and primary clinical application of inverted Y-shaped self-expandable metal airway stent

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Ma Ji; Yang Ruimin; Guan Sheng; Ma Nan; Wang Yanli

    2007-01-01

    Objective: To investigate the feasibility and primary therapeutic effect of inverted Y-shaped self-expandable metal stent for complex airway stenosis. Methods: On the standpoint of the peculiar anatomic structure and the pathological changes of complex airway stenosis, we designed the inverted Y-shaped self-expandable metal stent. Under the fluoroscopic guidance, 7 stents were implanted in 7 cases of airway complex stenosis. Results: The inverted Y-shaped self-expandable metal stents were placed seccussfully, with instantaneous relief of dyspnea and improvement of living quality. Conclusion: The placement of inverted Y-shaped self-expandable metal stent is feasible and safe for treating airway complex stenosis. (authors)

  13. Unlocking Resources: Self-Guided Student Explorations of Science Museum and Aquarium Exhibits

    Science.gov (United States)

    Kirkby, K. C.; Phipps, M.; Hamilton, P.

    2010-12-01

    traditional graded lab instruction and completely eclipse the range of gains normally achieved by traditional lecture instruction. In addition, the modules accomplish the remarkable goal of integrating undergraduate earth science instruction into students’ social life. Over three-fourths of the students complete the explorations with friends or family who were not enrolled in the class, expanding the course to include a broader, more diverse, audience. A third module, currently in development, will use a walking tour of Saint Anthony Falls to highlight the impact of geological processes on human society. Students will explore the waterfalls’ evolution, its early interpretation by 18th and 19th century Dakota and Euro-America societies, as well as its subsequent social and economic impacts on human history. The outdoor nature of this self-guided exploration is a first step towards expanding the modules’ concept to integrate self-guided field trips into undergraduate earth science curriculums.

  14. The treatment of complex airway diseases with inverted Y-shaped self-expandable metal stent

    International Nuclear Information System (INIS)

    Li Jianming; Jia Guangzhi

    2011-01-01

    Objective: To investigate the application and therapeutic effects of inverted Y-shaped self-expandable metal airway stent in treating complex airway diseases (stenosis or fistula). Methods: According to the distinctive anatomic structure and the pathological changes of complex airway stenosis or fistula, the inverted y-shaped self-expandable metal airway stent was designed. Under fluoroscopic monitoring, a total of 12 inverted Y-shaped self-expandable metal stents were implanted in 12 patients with complex airway diseases. Results: Stent placement in the trachea-bronchial tree was technically successful in all patients. After the operation, the symptom of dyspnea was immediately relieved and the bucking following food intake disappeared. The general physical condition and living quality were much improved in all patients. Conclusion: The use of inverted Y-shaped self-expandable metal airway stent for the management of complex airway stenosis involving the tracheal carina was a simple and safe procedure and it has satisfactory short-term clinical results. (authors)

  15. Treatment of tracheobronchial stenosis with a self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Jeon, Seok Chol; Choi, Chul Seung; Choi, Yo Won; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1994-07-15

    We analysed the role of modified Gianturco self-expandable stents in the treatment of tracheobronchial stenosis in 13 patients. We inserted modified Gianturco self-expandable stents under the fluoroscopic and bronchoscopic guidance. There were stenosis in the trachea(n=2), the right main bronchus(n=2), and the left main bronchus(n=9). The causes of the stenosis were endobronchial tuberculosis(n=10), intubation granuloma(n=1), restenosis after surgical reconstruction(n=2). Dyspnea or wheezing was improved within 1 or 2 days following the procedure. There were 32% and 22% respective increase in average FEV1 and FVC. Lung perfusion scan showed 9.6% increase of perfusion in the involved lung. No complications related to the procedure were encountered. During follow-up period of up to 31 months, 2 patients showed tracheal or bronchial restenosis, at 3 and 6 months, retrospectively. There was a distal migration of the stents in one case. During the follow up period after stent insertion, improvement of the obstructive changes and dyspnea persisted in 10 out of 13 patients. The modified Gianturco self-expandable metallic stents may be a good choice for the treatment of tracheobronchial stenosis, either as a primary treatment, or when the reconstruction failed.

  16. Long-term outcome of self expandable metal stents for biliary obstruction in chronic pancreatitis.

    Science.gov (United States)

    Waldthaler, Alexander; Schütte, Kerstin; Weigt, Jochen; Kropf, Siegfried; Malfertheiner, Peter; Kahl, Stefan

    2013-01-10

    Insertion of a self-expandable metal stent is still controversial for treatment of benign common bile duct stenosis but can be a valuable alternative to surgical treatment. Aim of our study was to analyze the efficacy of covered and uncovered self-expandable metal stent in patients with chronic pancreatitis and common bile duct stenosis. Twenty patients with common bile duct stenosis due to alcoholic chronic pancreatitis were retrospective analyzed. All patients had advanced chronic pancreatitis, presenting with calcifications in pancreatic head. Uncovered self-expandable metal stent (uSEMS) were used in 11 patients (3 females, 8 males) while in 9 patients (3 females, 6 males) partially covered self-expandable metal stent (cSEMS) were inserted. All patients treated with self-expandable metal stent had contraindications for surgery. Overall mean follow up time was 155 weeks: 206 (52-412) weeks in uSEMS, and 93 (25-233) weeks in cSEMS, respectively. Stent patency was in mean 118 weeks: 159 (44-412) weeks in uSEMS and 67 (25-150) weeks in cSEMS (P=0.019). In the uSEMS group, reintervention was necessary in 5 patients (45%) due to stent obstruction, whereas in the cSEMS group 4 patients (44%) needed reintervention (2 obstructions, 2 migration). Stent migration is an early complication, compared to obstruction (P<0.05), and in cSEMS obstruction occurred significantly earlier compared to uSEMS (P<0.05). Patency of uSEMS was significantly longer compared to partially cSEMS. Available self-expandable metal stent, unfortunately, do not meet the demands on successful treatment of benign common bile duct stenosis.

  17. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    Science.gov (United States)

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  18. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    Science.gov (United States)

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  19. Self-guide framing and persuasion: responsibly increasing message processing to ideal levels.

    Science.gov (United States)

    Evans, Lisa M; Petty, Richard E

    2003-03-01

    The current research examines the effect that framing persuasive messages in terms of self-guides (ideal vs. ought) has on the attitudes and cognitive responses of individuals with chronic ideal versus ought self-guides. The strength of participants' ideal and ought self-guides and the magnitude of participants' ideal and ought self-discrepancies were measured using a computerized reaction time program. One week later, participants read a persuasive message about a fictional breakfast product, framed in terms of either ideals or oughts. Matching framing to stronger self-guide led to enhanced message processing activity, especially among individuals who were low in need for cognition. Individuals who read messages framed to match their stronger self-guides paid more attention to argument quality, as reflected in their attitudes and cognitive responses. Messages with self-guide framing that matched individuals' stronger self-discrepancies did not have this effect on processing.

  20. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement.

    Science.gov (United States)

    Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J

    2016-01-05

    Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of

  1. Behavioral and Nondirective Guided Self-Help for Parents of Children with Externalizing Behavior: Mediating Mechanisms in a Head-To-Head Comparison.

    Science.gov (United States)

    Katzmann, Josepha; Hautmann, Christopher; Greimel, Lisa; Imort, Stephanie; Pinior, Julia; Scholz, Kristin; Döpfner, Manfred

    2017-05-01

    Parent training (PT) delivered as a guided self-help intervention may be a cost- and time-effective intervention in the treatment of children with externalizing disorders. In face-to-face PT, parenting strategies have repeatedly been identified as mediating mechanisms for the decrease of children's problem behavior. Few studies have examined possible mediating effects in guided self-help interventions for parents. The present study aimed to investigate possible mediating variables of a behaviorally oriented guided self-help program for parents of children with externalizing problems compared to a nondirective intervention in a clinical sample. A sample of 110 parents of children with externalizing disorders (80 % boys) were randomized to either a behaviorally oriented or a nondirective guided self-help program. Four putative mediating variables were examined simultaneously in a multiple mediation model using structural equation modelling. The outcomes were child symptoms of ADHD and ODD as well as child externalizing problems, assessed at posttreatment. Analyses showed a significant indirect effect for dysfunctional parental attributions in favor of the group receiving the behavioral program, and significant effects of the behavioral program on positive and negative parenting and parental self-efficacy, compared to the nondirective intervention. Our results indicate that a decrease of dysfunctional parental attributions leads to a decrease of child externalizing problems when parents take part in a behaviorally oriented guided self-help program. However, none of the putative mediating variables could explain the decrease in child externalizing behavior problems in the nondirective group. A change in dysfunctional parental attributions should be considered as a possible mediator in the context of PT.

  2. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Sabharwal, Tarun, E-mail: tarun_sabharwal@yahoo.co.uk [Guy' s and St. Thomas' Hospitals, NHS Foundation Trust, Department of Radiology (United Kingdom)

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  3. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    International Nuclear Information System (INIS)

    Krokidis, Miltiadis; Spiliopoulos, Stavros; Katsanos, Konstantinos; Sabharwal, Tarun

    2013-01-01

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  4. Feasibility of using bulk metallic glass for self-expandable stent applications.

    Science.gov (United States)

    Praveen Kumar, Gideon; Jafary-Zadeh, Mehdi; Tavakoli, Rouhollah; Cui, Fangsen

    2017-10-01

    Self-expandable stents are widely used to restore blood flow in a diseased artery segment by keeping the artery open after angioplasty. Despite the prevalent use of conventional crystalline metallic alloys, for example, nitinol, to construct self-expandable stents, new biomaterials such as bulk metallic glasses (BMGs) are being actively pursued to improve stent performance. Here, we conducted a series of analyses including finite element analysis and molecular dynamics simulations to investigate the feasibility of using a prototypical Zr-based BMG for self-expandable stent applications. We model stent crimping of several designs for different percutaneous applications. Our results indicate that BMG-based stents with diamond-shaped crowns suffer from severe localization of plastic deformation and abrupt failure during crimping. As a possible solution, we further illustrate that such abrupt failure could be avoided in BMG-based stents without diamond shape crowns. This work would open a new horizon for a quest toward exploiting superior mechanical and functional properties of metallic glasses to design future stents. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1874-1882, 2017. © 2016 Wiley Periodicals, Inc.

  5. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.

  6. SM50 repeat-polypeptides self-assemble into discrete matrix subunits and promote appositional calcium carbonate crystal growth during sea urchin tooth biomineralization.

    Science.gov (United States)

    Mao, Yelin; Satchell, Paul G; Luan, Xianghong; Diekwisch, Thomas G H

    2016-01-01

    The two major proteins involved in vertebrate enamel formation and echinoderm sea urchin tooth biomineralization, amelogenin and SM50, are both characterized by elongated polyproline repeat domains in the center of the macromolecule. To determine the role of polyproline repeat polypeptides in basal deuterostome biomineralization, we have mapped the localization of SM50 as it relates to crystal growth, conducted self-assembly studies of SM50 repeat polypeptides, and examined their effect on calcium carbonate and apatite crystal growth. Electron micrographs of the growth zone of Strongylocentrotus purpuratus sea urchin teeth documented a series of successive events from intravesicular mineral nucleation to mineral deposition at the interface between tooth surface and odontoblast syncytium. Using immunohistochemistry, SM50 was detected within the cytoplasm of cells associated with the developing tooth mineral, at the mineral secreting front, and adjacent to initial mineral deposits, but not in muscles and ligaments. Polypeptides derived from the SM50 polyproline alternating hexa- and hepta-peptide repeat region (SM50P6P7) formed highly discrete, donut-shaped self-assembly patterns. In calcium carbonate crystal growth studies, SM50P6P7 repeat peptides triggered the growth of expansive networks of fused calcium carbonate crystals while in apatite growth studies, SM50P6P7 peptides facilitated the growth of needle-shaped and parallel arranged crystals resembling those found in developing vertebrate enamel. In comparison, SM50P6P7 surpassed the PXX24 polypeptide repeat region derived from the vertebrate enamel protein amelogenin in its ability to promote crystal nucleation and appositional crystal growth. Together, these studies establish the SM50P6P7 polyproline repeat region as a potent regulator in the protein-guided appositional crystal growth that occurs during continuous tooth mineralization and eruption. In addition, our studies highlight the role of species

  7. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    Science.gov (United States)

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p stent use for palliation (78.6% vs 56.3%; p stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes of self-expandable metal stent placement and must be considered by endoscopists. See Video Abstract at http

  8. Self-expandable nitinol stent placement in homocysteinemic porcine aorta

    Directory of Open Access Journals (Sweden)

    Luís Henrique Gil França

    2008-01-01

    Full Text Available PURPOSE: To compare aortic intimal thickening of normal and hyperhomocysteinemic pigs (induced with a methionine-rich diet following placement of a self-expanding nitinol stent. METHODS: Eighteen Macau pigs were used. They were older than eight weeks in age and had an average weight of 30 kg. Pigs were randomly divided into two groups. The first, Group C (control, was fed a regular diet, and the second group, Group M, was fed a methionine-rich diet for 30 days to induce hyperhomocysteinemia. The self-expandable nitinol stents were 25mm in length and 8 mm in diameter after expansion. Blood samples were collected to measure total cholesterol, triglycerides, HDL and homocysteine concentrations. All animals were subjected to angiography. Thirty days after the procedure, the animals were sacrificed, and the abdominal aorta was removed for histological and digital morphometry analysis. RESULTS: Under microscopic evaluation, the intima was significantly thicker in Group C than in Group M. When groups were compared by digital morphometric analysis, intimal thickening of the vessel wall was higher in Group C than in Group M. There was no significant change in total cholesterol, triglycerides or HDL concentrations in either group. In group C the levels of plasma homocysteine ranged from 14,40 to 16,73µmol/l; in Group M, plasma homocysteine levels ranged from 17.47 to 59.80 µmol/l after 30 days of a methionine-rich diet. CONCLUSION: Compared to normal pigs, less intimal hyperplasia was observed in the abdominal aortas of hyperhomocysteinemic pigs thirty days after the insertion of a self-expandable nitinol stent.

  9. Self-expandable metal stent placement in a child for treatment of achalasia after failed Heller myotomy.

    Science.gov (United States)

    Gugig, Roberto; Muñoz Jurado, Guillermo; Huang, Clifton; Oleas, Roberto; Robles-Medranda, Carlos

    2018-01-01

    Background and study aims  Childhood achalasia treatment remains inconclusive. What is next after myotomy failure? Repeated pneumatic-dilation put patients at greater risk of perforation with possible symptom recurrence. We report on a 12-year-old patient with a 1-year history of achalasia whom underwent Heller myotomy with fundoplication and recurred with symptoms 1 week after surgery. Pneumatic dilatation was considered but not done because of the risk of esophageal perforation. The decision was made to place a fully covered self-expanding metallic stent (FC-SEMS) for 3 months, which resolved the stenosis as confirmed by esophagram. The patient has remained asymptomatic since the procedure was performed 2 years ago. FC-SEMS is an alternative for treatment of refractory achalasia in children who do not respond to conventional treatment.

  10. Double-Balloon Catheter for Isolated Liver Perfusion: An Experimental Study

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Bergqvist, Lennart; Harnek, Jan

    2001-01-01

    Purpose: Further development of a previously described interventional method for isolated liver perfusion (ILP) with a new double-lumen balloon catheter, and evaluation of the side-effects of such isolation.Methods: In six pigs a double-balloon occlusion catheter was placed via the transjugular approach with its tip in the portal vein. One of the balloons was positioned in the inferior vena cava (IVC), cranial to the origin of the hepatic veins and the other balloon in the portal vein. By the transfemoral approach, a single-balloon occlusion catheter was placed in the IVC caudal to the origin of the hepatic veins. A third catheter was placed by the transfemoral route with the occlusion balloon in the proper hepatic artery. After inflation of all balloons 99 Tc m -labelled human serum albumin was recirculated through the liver. The isolation was evaluated by repeated measurement of radioactivity levels in peripheral blood. Laboratory tests of liver and pancreas function, and hemoglobin, were taken before, at the end of, and 3 days after the procedure. Blood gases were tested at the beginning and end of the procedure.Results: One pig died during the procedure due to technical failure and was excluded from the study. In the other pigs leakage from the isolated liver to the systemic circulation increased slowly, up to 9.7% (mean) during 30 min of recirculation of the perfusate through the liver. Laboratory tests were normal in all pigs except insignificant acidosis directly after the procedure and the slight elevation of s-ALAT after 3 days.Conclusions: Only minor leakage from the liver to the systemic circulation was noted during ILP performed with a new, double-balloon catheter. There were no serious side effects

  11. Mentor-guided self-directed learning affects resident practice.

    Science.gov (United States)

    Aho, Johnathon M; Ruparel, Raaj K; Graham, Elaina; Zendejas-Mummert, Benjamin; Heller, Stephanie F; Farley, David R; Bingener, Juliane

    2015-01-01

    Self-directed learning (SDL) can be as effective as instructor-led training. It employs less instructional resources and is potentially a more efficient educational approach. Although SDL is encouraged among residents in our surgical training program via 24-hour access to surgical task trainers and online modules, residents report that they seldom practice. We hypothesized that a mentor-guided SDL approach would improve practice habits among our residents. From 2011 to 2013, 12 postgraduate year (PGY)-2 general surgery residents participated in a 6-week minimally invasive surgery (MIS) rotation. At the start of the rotation, residents were asked to practice laparoscopic skills until they reached peak performance in at least 3 consecutive attempts at a task (individual proficiency). Trainees met with the staff surgeon at weeks 3 and 6 to evaluate progress and review a graph of their individual learning curve. All trainees subsequently completed a survey addressing their practice habits and suggestions for improvement of the curriculum. By the end of the rotation, 100% of participants improved in all practiced tasks (p mentor-guided SDL. Additionally, 6 (50%) residents reported that their skill level had improved relative to their peers. Some residents (n = 3) felt that the curriculum could be improved by including task-specific goals and additional practice sessions with the staff surgeon. Mentor-guided SDL stimulated surgical residents to practice with greater frequency. This repeated deliberate practice led to significantly improved MIS skills without significantly increasing the need for faculty-led instruction. Some residents preferred more discrete goal setting and increased mentor guidance. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  12. Malignant biliary obstruction: percutaneous use of self-expandable stents

    NARCIS (Netherlands)

    Laméris, J. S.; Stoker, J.; Nijs, H. G.; Zonderland, H. M.; Terpstra, O. T.; van Blankenstein, M.; Schütte, H. E.

    1991-01-01

    A total of 83 self-expandable metallic stents were placed percutaneously in 69 patients for palliation of malignant biliary obstruction. Stent diameter was 1 cm; length, 3.5-10.5 cm. Of the 41 patients with common bile duct obstruction, 27 died 0.2-12 months (median, 3.2 months) after stent

  13. Shear flow generation and turbulence suppression by resistive ballooning and resistive interchange modes

    International Nuclear Information System (INIS)

    Guzdar, P.N.; Drake, J.F.

    1993-01-01

    The generation of shear flow by resistive ballooning modes and resistive interchange modes is compared and contrasted using a 3-D fluid code. The resistive ballooning modes give rise to poloidally asymmetric transport and hence drive poloidal rotation due to the Reynold's Stress as well as the anomalous Stringer/Winsor mechanism. On the other hand the resistive interchange mode can drive shear flow only through the Reynold's Stress. The studies show that if the self-consistent sheared flow is suppressed, the resistive ballooning modes give rise to a larger anomalous transport than produced by the resistive interchange modes. Furthermore the shear flow generated by the resistive ballooning modes is larger than that driven by the resistive interchange modes due to the combined effect of the dual mechanisms stated earlier. As a consequence strong suppression of the fluctuations as well as reduction of the transport occurs for resistive ballooning modes. On the other hand, for the resistive interchange modes the level of fluctuation as well as the anomalous transport is not reduced by the self consistent shear flow generated by the Reynold's Stress. This latter result is in agreement with some earlier 3-D simulation of resistive interchange modes

  14. Rupture of the Renal Artery After Cutting Balloon Angioplasty in a Young Woman With Fibromuscular Dysplasia

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Gulcan, Oner; Turkoz, Riza

    2005-01-01

    A 24-year-old woman with uncontrollable high blood pressure for 3 months had significant stenosis of the left renal artery caused by fibromuscular dysplasia (FMD). The lesion was resistant to percutaneous transluminal angioplasty at 18 atm with a semicompliant balloon. Angioplasy with a 6 x 10 mm cutting balloon (CB) caused rupture of the artery. Low-pressure balloon inflation decreased but did not stop the leak. An attempt to place a stent-graft (Jostent; Jomed, Rangendingen, Germany) failed, and a bare, 6-mm balloon-expandable stent (Express SD; Boston Scientific, MN) was deployed to seal the leak, which had decreased considerably after long-duration balloon inflation. The bleeding continued, and the patient underwent emergent surgical revascularization of the renal artery with successful placement of a 6-mm polytetrafluoroethylene bypass graft. CBs should be used very carefully in the treatment of renal artery stenosis, particularly in patients with FMD

  15. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections

    DEFF Research Database (Denmark)

    Walter, Daisy; Will, Uwe; Sanchez-Yague, Andres

    2015-01-01

    BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the effi......BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate...

  16. Solid State Inflation Balloon Active Deorbiter: Scalable Low-Cost Deorbit System for Small Satellites

    Science.gov (United States)

    Huang, Adam

    2016-01-01

    The goal of the Solid State Inflation Balloon Active Deorbiter project is to develop and demonstrate a scalable, simple, reliable, and low-cost active deorbiting system capable of controlling the downrange point of impact for the full-range of small satellites from 1 kg to 180 kg. The key enabling technology being developed is the Solid State Gas Generator (SSGG) chip, generating pure nitrogen gas from sodium azide (NaN3) micro-crystals. Coupled with a metalized nonelastic drag balloon, the complete Solid State Inflation Balloon (SSIB) system is capable of repeated inflation/deflation cycles. The SSGG minimizes size, weight, electrical power, and cost when compared to the current state of the art.

  17. Early recurrence of obstructive jaundice after placement of a self-expanding metal endoprosthesis

    NARCIS (Netherlands)

    Fockens, P.; Waxman, I.; Davids, P. H.; Huibregtse, K.; Tytgat, G. N.

    1992-01-01

    Self-expanding metal endoprostheses have ben used in the treatment of malignant obstructive jaundice for a few years. We report on a patient with obstructive jaundice due to a metastasis of a squamous cell lung cancer into the pancreatic head who received an expandable metal endoprosthesis and

  18. Primary Self-Expandable Nitinol Stent Placement in Focal Lesions of Infrarenal Abdominal Aorta: Long Term Results

    International Nuclear Information System (INIS)

    Lastovickova, Jarmila; Peregrin, Jan H.

    2008-01-01

    Purpose. To evaluate the technical and clinical success, safety and long term results of percutaneous transluminal angioplasty/self-expandable nitinol stent placement of infrarenal abdominal aorta focal lesions. Materials and Methods. Eighteen patients underwent PTA of focal atherosclerotic occlusive disease of distal abdominal aorta. Two symptomatic occlusions and 16 stenoses in 10 male and 8 female patients (mean age 68.2 years) were treated with primary self-expandable nitinol stent placement. Results. Primary self-expandable nitinol stent placement was technically successful in all 18 procedures; clinical success was achieved in 100% of patients. No complications associated with the procedure occurred. During the 49.4 months of mean follow up (range 3-96, 4 months) all treated aortic segments remained patent. Conclusions. Endovascular treatment (primary self-expandable nitinol stent placement) of focal atherosclerotic lesions of distal abdominal aorta is a safe method with excellent primary technical and clinical success rates and favourable Long term results

  19. Cultural Differences in Values as Self-Guides.

    Science.gov (United States)

    Cheung, Wing-Yee; Maio, Gregory R; Rees, Kerry J; Kamble, Shanmukh; Mane, Sangeetha

    2016-06-01

    Three studies tested whether individualism-collectivism moderates the extent to which values are endorsed as ideal self-guides and ought self-guides, and the consequences for regulatory focus and emotion. Across Studies 1 and 2, individualists endorsed values that are relatively central to the self as stronger ideals than oughts, whereas collectivists endorsed them as ideals and oughts to a similar degree. Study 2 found that individualists justified central values using reasons that were more promotion focused than prevention focused, whereas collectivists used similar amount of prevention-focused and promotion-focused reasons. In Study 3, individualists felt more dejected after violating a central (vs. peripheral) value and more agitated after violating a peripheral (vs. central) value. Collectivists felt a similar amount of dejection regardless of values centrality and more agitation after violating central (vs. peripheral) values. Overall, culture has important implications for how we regulate values that are central or peripheral to our self-concept. © 2016 by the Society for Personality and Social Psychology, Inc.

  20. A self-adjusting expandable GPS collar for male elk

    Science.gov (United States)

    Brian L. Dick; Scott L. Findholt; Bruce K. Johnson

    2013-01-01

    It is a challenge to use collars on male cervids because their neck size can increase substantially during the rut and also because of growth as the animal matures. We describe how to build a self-adjusting expandable collar for yearling or adult male Rocky Mountain elk (Cervus elaphus) to which very high frequency transmitters and global...

  1. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    International Nuclear Information System (INIS)

    Lopera, Jorge E.; Alvarez, Alex; Trimmer, Clayton; Josephs, Shellie; Anderson, Matthew; Dolmatch, Bart

    2009-01-01

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm 3 , respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

  2. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  3. Percutaneous metallic self-expandable endoprostheses in malignant hilar biliary obstruction

    NARCIS (Netherlands)

    Stoker, J.; Laméris, J. S.; van Blankenstein, M.

    1993-01-01

    Forty-five patients with malignant hilar obstruction were treated with a total of 68 percutaneously inserted metallic self-expandable endoprostheses (Wallstents) for palliative biliary drainage. The stent diameter was 1 cm; the length was 3.5 to 10.5 cm. Early complications occurred in seven

  4. Balloon dacryocystoplasty: Incomplete versus complete obstruction of the nasolacrimal system

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Sang Hoon; Han, Young Min; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul; Song, Ho Young

    1993-01-01

    Balloon dilatation of nasolacrimal drainage apparatus was attempted for the treatment of stenoses or obstructures of the nasolacrimal system in 49 eyes of 41 consecutive patients with complete obstructions and 16 eyes of 14 patients with incomplete obstructions. These two groups were compared with regards to the effectiveness of balloon dacryocystoplasty. All patients suffered from severe epiphora had already undergone multiple probings. A 0.018 inch hair or ball guide wire was introduced through the superior punctum into the inferior meatus of the nasal cavity and pulled out through the nasal aperture using a hemostat under nasal endoscopy. A deflated angiography balloon catheter was then introduced in a retrograde direction and dilated under fluoroscopic control. No major complications occurred in any of the patients. At 7 days after balloon dilatation, 25 of 49 eyes with complete obstruction demonstrated improvement in epiphora (initial success rate: 51.0%) and among them 17 eyes showed complete resolution of symptoms. Reocclusion occurred in 12 of the 25 eyes with initial improvement at the 2 months follow up. For the 16 eyes with incomplete obstruction, and improvement of epiphora was attained in 11 eyes (initial success rate 68.8%): 5 of these eyes showed complete resolution of epiphora, and 3 was failed to maintain initial improvement at the 2 month follow up. Although this study demonstrate that results of balloon dacryocystoplasty are not encouraging because of the high failure and recurrence rate, balloon dacryocystoplasty is a simple and safe nonsurgical technique that can be used to treat for obstructions of the nasolacrimal system. In addition, balloon dacryocystoplasty shows better results in incomplete obstruction than in complete obstruction than complete obstruction of the nasolacrimal system

  5. Endoscopic management of complications of self-expandable metal stents for treatment of malignant esophageal stenosis and tracheoesophageal fistulas.

    Science.gov (United States)

    Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán

    2017-08-01

    Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.

  6. Deflation of the ′obstinate′ Foley′s urinary catheter balloon : a new technique.

    Directory of Open Access Journals (Sweden)

    Ramakantan R

    1989-01-01

    Full Text Available We have successfully deflated "obstinate" Foley′s urinary catheter balloons in 15 cases in the last six months with the help of a simple bedside procedure using an angiographic guide-wire.

  7. Adult Beginner Instrumentalists' Practice, Self-Regulation, and Self-Efficacy: A Pilot Study

    Science.gov (United States)

    Ritchie, Laura; Kearney, Phil

    2018-01-01

    The self-regulation of practice behaviour has repeatedly been shown to distinguish between novice and expert performers, however interventions designed to encourage self-regulation by novice musicians have shown limited effectiveness. Guided by successful research in sporting contexts, the present study investigated the behaviours of beginner…

  8. Faculty staff-guided versus self-guided ultrasound training for internal medicine residents.

    Science.gov (United States)

    Alba, George A; Kelmenson, Daniel A; Noble, Vicki E; Murray, Alice F; Currier, Paul F

    2013-11-01

    Ultrasonography is of growing importance within internal medicine (IM), but the optimal method of training doctors to use it is uncertain. In this study, the authors provide the first objective comparison of two approaches to training IM residents in ultrasonography. In this randomised trial, a simulation-based ultrasound training curriculum was implemented during IM intern orientation at a tertiary care teaching hospital. All 72 incoming interns attended a lecture and were given access to online modules. Interns were then randomly assigned to a 4-hour faculty-guided (FG) or self-guided (SG) ultrasound training session in a simulation laboratory with both human and manikin models. Interns were asked to self-assess their competence in ultrasonography and underwent an objective structured clinical examination (OSCE) to assess their competence in basic and procedurally oriented ultrasound tasks. The primary outcome was the score on the OSCE. Faculty-guided training was superior to self-guided training based on the OSCE scores. Subjects in the FG training group achieved significantly higher OSCE scores on the two subsets of task completion (0.9-point difference, 95% confidence interval [CI] 0.27-1.54; p = 0.008) and ultrasound image quality (2.43-point difference, 95% CI 1.5-3.36; p training groups demonstrated an increase in self-assessed competence after their respective training sessions and there was little difference between the groups. Subjects rated the FG training group much more favourably than the SG training group. Both FG and SG ultrasound training curricula can improve the self-reported competence of IM interns in ultrasonography. However, FG training was superior to SG training in both skills acquisition and intern preference. Incorporating mandatory ultrasound training into IM residencies can address the perceived need for ultrasound training, improve confidence and procedural skills, and may enhance patient safety. However, the optimal training method

  9. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis – Report of 7 Consecutive Patients with Serial ERC Approach

    Science.gov (United States)

    Stojkovic, Marija; Junghanss, Thomas; Veeser, Mira; Weber, Tim F.; Sauer, Peter

    2016-01-01

    Background and Aims Biliary vessel pathology due to alveolar echicococcosis (AE) results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography) balloon dilation for AE biliary pathology. Methods Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed. Results Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed “sustained clinical success” and four patients “assisted therapeutic success,” of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS). There was no loss to follow up. No major complications were observed. Conclusions Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current

  10. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis--Report of 7 Consecutive Patients with Serial ERC Approach.

    Directory of Open Access Journals (Sweden)

    Marija Stojkovic

    2016-02-01

    Full Text Available Biliary vessel pathology due to alveolar echicococcosis (AE results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography balloon dilation for AE biliary pathology.Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed.Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed "sustained clinical success" and four patients "assisted therapeutic success," of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS. There was no loss to follow up. No major complications were observed.Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current ERC guidelines and is minimally disruptive

  11. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis--Report of 7 Consecutive Patients with Serial ERC Approach.

    Science.gov (United States)

    Stojkovic, Marija; Junghanss, Thomas; Veeser, Mira; Weber, Tim F; Sauer, Peter

    2016-02-01

    Biliary vessel pathology due to alveolar echicococcosis (AE) results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography) balloon dilation for AE biliary pathology. Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed. Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed "sustained clinical success" and four patients "assisted therapeutic success," of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS). There was no loss to follow up. No major complications were observed. Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current ERC guidelines and is minimally disruptive for patients.

  12. Use of covered self-expandable stents for benign colorectal disorders in children.

    Science.gov (United States)

    Lange, Bettina; Sold, Moritz; Kähler, Georg; Wessel, Lucas M; Kubiak, Rainer

    2017-01-01

    There is a lack of experience with covered self-expandable stents for benign colorectal disorders in children. Five children (4M, 1F) with a median age of 5years (range, 6months-9years) who underwent treatment with covered self-expandable plastic (SEPSs) or self-expandable metal stents (SEMSs) for a benign colorectal condition between April 2005 and November 2013 were recruited to this retrospective study. Etiologies included: anastomotic stricture with (n=1) or without (n=3) simultaneous enterocutaneous fistula, as well as an anastomotic leak associated with enterocutaneous fistula (n=1). All children suffered from either Hirschsprung's disease (n=3) or total colonic aganglionosis (Zuelzer-Wilson syndrome) (n=2). Median duration of individual stent placement was 23days (range, 1-87days). In all cases up to five different stents were placed over time. At follow-up two patients were successfully treated without further intervention. In another patient the anastomotic stricture resolved fully, but a coexisting enterocutaneous fistula persisted. Overall, three patients did not improve completely following stenting and required definite surgery. Stent-related problems were noted in all cases. There was one perforation of the colon at stent insertion. Further complications consisted of stent dislocation (n=4), obstruction (n=1), formation of granulation tissue (n=1), ulceration (n=1) and discomfort (n=3). Covered self-expandable stents enrich the armamentarium of interventions for benign colorectal disorders in children including anastomotic strictures and intestinal leaks. A stent can be applied either as an emergency procedure (bridge to surgery) or as an adjuvant treatment further to endoscopy and dilatation. Postinterventional problems are frequent but there is a potential for temporary or definite improvement following stent insertion. Copyright © 2017. Published by Elsevier Inc.

  13. Safety and efficacy of self-expandable metal stents for obstructive proximal and distal large bowel cancer.

    Science.gov (United States)

    Mitra, V; Hu, M; Majumdar, D; Krishnan, V; Chaudhury, B; Hancock, J; Dwarakanath, D

    2017-03-01

    Self-expandable metal stents are often used to treat obstructive large bowel cancers. This study assessed the safety and efficacy of colonic stent insertion carried out in a district general hospital. Methods A retrospective review was carried out between 1 January 2007 and 28 February 2014 to identify patients who underwent stent insertion for malignant colorectal obstruction. Results Seventy-five patients (median age 75.2 years, 70.6% male) with primary colorectal cancer underwent stent insertion - 53 underwent semi-elective self-expanded metal stent insertion (for subacute bowel obstruction) and 22 had emergency stent inserted (for acute bowel obstruction). The majority (88%) had self-expanded metal stents inserted for palliation. Technical and clinical success rates were 98.7% and 91.2%, respectively. One patient had stent-related perforation; there was no procedure-related mortality. Conclusion This study shows that self-expanded metal stent insertion in malignant colorectal obstruction is safe and effective and can be successfully delivered in a district general hospital with high technical and clinical success rates.

  14. An infinitely expandable cloning strategy plus repeat-proof PCR for working with multiple shRNA.

    Directory of Open Access Journals (Sweden)

    Glen John McIntyre

    Full Text Available Vector construction with restriction enzymes (REs typically involves the ligation of a digested donor fragment (insert to a reciprocally digested recipient fragment (vector backbone. Creating a suitable cloning plan becomes increasingly difficult for complex strategies requiring repeated insertions such as constructing multiple short hairpin RNA (shRNA expression vectors for RNA interference (RNAi studies. The problem lies in the reduced availability of suitable RE recognition sites with an increasing number of cloning events and or vector size. This report details a technically simple, directional cloning solution using REs with compatible cohesive ends that are repeatedly destroyed and simultaneously re-introduced with each round of cloning. Donor fragments can be made by PCR or sub-cloned from pre-existing vectors and inserted ad infinitum in any combination. The design incorporates several cloning cores in order to be compatible with as many donor sequences as possible. We show that joining sub-combinations made in parallel is more time-efficient than sequential construction (of one cassette at a time for any combination of 4 or more insertions. Screening for the successful construction of combinations using Taq polymerase based PCR became increasingly difficult with increasing number of repeated sequence elements. A Pfu polymerase based PCR was developed and successfully used to amplify combinations of up to eleven consecutive hairpin expression cassettes. The identified PCR conditions can be beneficial to others working with multiple shRNA or other repeated sequences, and the infinitely expandable cloning strategy serves as a general solution applicable to many cloning scenarios.

  15. GRAINE balloon experiment in 2015

    Directory of Open Access Journals (Sweden)

    Rokujo Hiroki

    2017-01-01

    Full Text Available Observations of cosmic gamma rays are important for studying high energy phenomena in the universe. Since 2008, the Large Area Telescope on the Fermi satellite has surveyed the whole gamma-ray sky in the sub-GeV/GeV energy region, and accumurated a large amount of data. However, observations at the low galactic latitude remains difficult because of a lack of angular resolution, increase of background flux originating from galactic diffuse gamma rays, etc. The Gamma-Ray Astro-Imager with Nuclear Emulsion (GRAINE is a gamma-ray observation project with a new balloon-borne emulsion gamma-ray telescope. Nuclear emulsion is a high-resolution 3D tracking device. It determines the incident angle with 0.1∘ resolution for 1 GeV gamma rays (1.0∘ for 100 MeV, and has linear polarization sensitivity. GRAINE aims at precise observation of gamma-ray sources, especially in the galactic plane, by repeating long-duration balloon flights with large-aperture-area (10 m2 high-resolution emulsion telescopes. In May 2015, we performed a balloon-borne experiment in Alice Springs, Australia, in order to demonstrate the imaging performance of our telescope. The emulsion telescope that has an aperture area of 0.4 m2 was employed in this experiment. It observed the Vela pulsar (the brightest gamma-ray source in the GeV sky at an altitude of 37 km for 6 hours out of the flight duration of 14 hours. In this presentation, we will report the latest results and the status of the GRAINE project.

  16. Palliative of malignant esophageal stenoses and their complications using self-expandable stets

    International Nuclear Information System (INIS)

    Manova, G.; Totev, M.; Kamburov, V.; Tcherveniakov, A.; Spaskov, S.

    2006-01-01

    Full text: One of the best modalities to improve quality of live of the patients with malignant dysphagia, who are bad candidates for surgery, is stenting with self-expandable metal stents. In critically ill patients it remains the last therapeutic possibility. The aim of the study is to evaluate the combined endoscopic- radiological approach in treatment of the dysphagia with malignant origin using self expandable metal stents in unsuitable for surgery patients. Between 10.2002 and 04.2006 we studied 42 consecutive patients (36 males and 6 females), mean age 63.3 (SD=8.28) years with advanced (range 3, 4 and 5) dysphagia. All patients had metastatic disease, four of them were critically ill (aspiration pneumonia due to malignant fistula). The manipulation was performed by one endoscopist, one radiologist and one assistant with combined endoscopically- radiological approach. After obtaining informed consent and sedating the patient, we insert a firm canula trough the scope and instill iodine contrast. We mark the edges of the stenosis on the skin, choose a stent with proper length, place a stiff guide wire via the endoscopic channel and remove the scope. We used covered self-expandable metal stents FerX-ELLA (Hradec Kralove, Czechs Republic) with antireflux valves. We insert the delivery system over the wire, position the prosthesis under x-ray control according to the skin marks and release the stent. In 34 cases the reason for dysphagia was primary tumor (7 - middle third, 22 - distal third of the esophagus, five - cardia). In five cases the dysphagia was due to recurrence after gastrooesophagoplasty. Another five patients presented with malignant esophageal-respiratory fistula. In 52% the histology of the tumor revealed adenocarcinoma, in 40% - squamocellular and in 8% adenosquamous carcinoma. In tree cases there was extrinsic compression due to mediastinal mass (two bronchial carcinoma, one lymphoma). Technically successful one-step manipulation was achieved in

  17. Energy from solar balloons

    Energy Technology Data Exchange (ETDEWEB)

    Grena, Roberto [C. R. Casaccia, via Anguillarese 301, 00123 Roma (Italy)

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  18. Relational stressors as predictors for repeat aggressive and self-harming incidents in child and adolescent psychiatric inpatient settings.

    Science.gov (United States)

    Ulke, Christine; Klein, Annette M; von Klitzing, Kai

    2014-01-01

    This study examined whether relational stressors such as psychosocial stressors, the therapist's absence and a change of therapist are associated with repeat aggressive or self-harming incidents in child and adolescent psychiatric inpatient care. The study data were derived from critical incident reports and chart reviews of 107 inpatients. In multinomial regression analysis, patients with repeat aggressive or self-harming incidents were compared with patients with single incidents. Results suggested that a higher number of psychosocial stressors and a change of therapist, but not the therapist's absence are predictors for repeat aggressive and self-harming incidents. There was a high prevalence of therapist's absence during both, single and repeat, incidents. Repeat aggressive incidents were common in male children and adolescents with disruptive behavior disorders. Repeat self-harming incidents were common in adolescent females with trauma-related disorders. Patients with repeat aggressive or self-harming incidents had a higher number of abnormal intrafamilial relationships and acute life events than patients with single incidents. Interventions to reduce a change of therapist should in particular target children and adolescents with a higher number of psychosocial stressors and/or a known history of traumatic relational experiences. After a first incident, patients should have a psychosocial assessment to evaluate whether additional relational support is needed.

  19. Transcatheter aortic-valve replacement with a self-expanding prosthesis.

    Science.gov (United States)

    Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Yakubov, Steven J; Coselli, Joseph S; Deeb, G Michael; Gleason, Thomas G; Buchbinder, Maurice; Hermiller, James; Kleiman, Neal S; Chetcuti, Stan; Heiser, John; Merhi, William; Zorn, George; Tadros, Peter; Robinson, Newell; Petrossian, George; Hughes, G Chad; Harrison, J Kevin; Conte, John; Maini, Brijeshwar; Mumtaz, Mubashir; Chenoweth, Sharla; Oh, Jae K

    2014-05-08

    We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).

  20. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  1. Cutting through the Hype: The Essential Guide to School Reform. Revised, Expanded, and Updated Edition

    Science.gov (United States)

    David, Jane L.; Cuban, Larry

    2010-01-01

    "Cutting Through the Hype: The Essential Guide to School Reform" is a revised, expanded, and updated version of the classic work by Jane L. David and Larry Cuban. It offers balanced analyses of 23 currently popular school reform strategies, from teacher performance pay and putting mayors in charge to turnaround schools and data-driven instruction.…

  2. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  3. Temporary placement of stent grafts in postsurgical benign biliary strictures: a single center experience.

    Science.gov (United States)

    Vellody, Ranjith; Willatt, Jonathon M; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  4. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B [Division of Interventional Radiology, University of Michigan, Ann Arbor (United States)

    2011-11-15

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  5. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    International Nuclear Information System (INIS)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  6. Balloon dilatation of nasopharyngeal stenosis in a dog.

    Science.gov (United States)

    Berent, Allyson C; Kinns, Jennifer; Weisse, Chick

    2006-08-01

    A dog was examined because of a 6-month history of upper airway stridor that began after postoperative regurgitation of gastric contents. Constant stridor was evident during inspiration and expiration, although it was worse during inspiration. The stridor was no longer evident when the dog's mouth was manually held open. Computed tomography, rhinoscopy, and fluoroscopy were used to confirm a diagnosis of nasopharyngeal stenosis. The dog was anesthetized, and balloon dilatation of the stenosis was performed. Prednisone was prescribed for 4 weeks after the procedure to decrease fibrous tissue formation. Although the dog was initially improved, signs recurred 3.5 weeks later, and balloon dilatation was repeated. This time, however, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Two months later, although the dog did not have clinical signs of stridor, a third dilatation procedure was performed because mild stenosis was seen on follow-up computed tomographic images; again, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Three and 6 months after the third dilatation procedure, the dog reportedly was clinically normal. Findings suggest that balloon dilatation may be an effective treatment for nasopharyngeal stenosis in dogs.

  7. A study on usefulness of balloon cholangiography in operating ERCP

    International Nuclear Information System (INIS)

    Son, Soon Yong

    1997-01-01

    Purpose of this paper is to extend help for clinical application in balloon cholangiography on patients who have undergone endoscopic sphincterotomy, impacted stones of intrahepatic duct, and missed bile duct because of other diseases in operating endoscopic retrograde cholangio pancreatography. This study was done for the patients who had clinical signs of biliary diseases from January to December in 1996. We studied 45 patients who had endoscopic sphincterotomy, re-examination after interventional treatment of the endoscopic retrograde cholangio pancreatography, and uncertain diagnosis due to common bile duct and intrahepatic duct those are not filled with contrast media. Balloon cholangiography was performed in case of uncertain diagnosis while operating endoscopic retrograde cholangio pancreatography. First of all, we insert balloon catheter into the working channel of treatment jejunofiberscope and remove treatment jejunofiberscope after ballooning, and lastly take biliary tract X-ray after injection and changing position of patient. The results of this study were as follows. (1) In classification of diseases, stones of gall bladder, those of common bile duct, and those of intrahepatic duct were 30 cases, fistula was 1 case. (2) In total cases of 45, only diagnosis were 25 cases, interventional treatment were 20 cases. (3) In case of interventional treatment, endoscopic sphincterotomy and endoscopic nasobiliary drainage, and stone removal were about the same, 7, 7, 6 respectively. Balloon cholangiography will be useful to prevent patients from having repeated and unnecessary studies for the cases above explained. It is considered that this study will be useful for clinical application in terms of reducing medical expenses, pain while examination, and consultation hours

  8. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  9. The use of self expandable metallic stent in the management of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Han, Joon Koo; Choi, Byung Ihn; Chung, Jin Wook; Park, Jae Hyung; Han, Gi Seok; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-05-15

    Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patient with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: three with gallbladder cancer: seven with Klaskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three case, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409 days). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and can eliminate major disadvantages of PTBD. Overstenting, overlapping and evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency.

  10. The use of self expandable metallic stent in the management of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Han, Joon Koo; Choi, Byung Ihn; Chung, Jin Wook; Park, Jae Hyung; Han, Gi Seok; Han, Man Chung

    1993-01-01

    Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patient with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: three with gallbladder cancer: seven with Klaskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three case, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409 days). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and can eliminate major disadvantages of PTBD. Overstenting, overlapping and evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency

  11. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  12. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  13. A Study on the Guided Wave Mode Conversion using Self-calibrating Technique

    International Nuclear Information System (INIS)

    Park, Jung Chul; Cho, Youn Ho

    2000-01-01

    The guided wave mode conversion phenomena were investigated for the NDE of a plate-like structure with thickness variation. The ratios of reflection and transmission (R/T) were measured via the self-calibrating procedure which allows us to obtain experimental guided wave data in a more reliable way regardless of the coupling uncertainty between transducer and specimen. The results on R/T could be used to determine the thickness reduction of the structure. It was shown that not only the incident modes but also the converted ones need to be considered in the self-calibrating guided wave inspection to extract a reasonable correlation between experimental data and the thickness variation. Through this study, the potential of guided wave inspection as a quantitative NDE technique was explored based on the combined concept of self-calibration and multi-mode conversion in guided wave scattering problems

  14. Environment, Safety, and Health (ES&H) self-assessment guide

    Energy Technology Data Exchange (ETDEWEB)

    Reese, R.T.; Golden, N.L.; Romero, J.R.; Yesner, S.

    1997-06-01

    This document has been prepared as a guide for conducting self-assessments of ES&H functional programs and organizational (line) implementation of these programs. This guide is intended for use by individuals and/or teams involved in or familiar with ES&H programs and line operations (e.g., the {open_quotes}self{close_quotes}in self-assessment). Essential elements of the self-assessment process are described including: schedule and priorities, scope and approach, assessment criteria (e.g., performance objectives and measures), information gathering and analysis techniques, and documentation of planning efforts and results. The appendices in this guide include: (1) an assessment prioritization process, (2) generic performance objectives for line implementation and for ES&H functional programs, (3) sources for ES&H assessment information, (4) systemic factors (developed for SNL`s root cause analysis program), (5) Lockheed Martin audit questions for management systems, compliance and validation, and specific areas and concerns, (6) DOE facility representatives checklist, and (7) assessment tools and resources developed at SNL and other DOE/Lockheed Martin sites. This document is a product of the efforts associated with the SNL ES&H Oversight Pilot Project conducted from June 1995 to January 1997. This Pilot was part of the overall initiative by DOE to reduce burdensome agency oversight by placing greater reliance on contractor self-assessment.

  15. Balloon sinuplasty

    OpenAIRE

    Ahmad, Zahoor

    2010-01-01

    Balloon sinuplasty is a technique in endoscopic sinus surgery that involves minimally invasive procedures to dilate the obstructed or stenosed anatomical sinus pathways. Procedure is derived from the well-recognized techinique of angioplasty. This article highlights the procedural methods with review of literature and my personal experience in balloon sinupalsty.

  16. Impact of depressive symptoms, self-esteem and neuroticism on trajectories of overgeneral autobiographical memory over repeated trials.

    Science.gov (United States)

    Kashdan, Todd B; Roberts, John E; Carlos, Erica L

    2006-04-01

    The present study examined trajectories of change in the frequency of overgeneral autobiographical memory (OGM) over the course of repeated trials, and tested whether particular dimensions of depressive symptomatology (somatic and cognitive-affective distress), self-esteem, and neuroticism account for individual differences in these trajectories. Given that depression is associated with impairments in effortful processing, we predicted that over repeated trials depression would be associated with increasingly OGM. Generalised Linear Mixed Models with Penalised Quasi-Likelihood demonstrated significant linear and quadratic trends in OGM over repeated trials, and somatic distress and self-esteem moderated these slopes. The form of these interactions suggested that somatic distress and low self-esteem primarily contribute to OGM during the second half of the trial sequence. The present findings demonstrate the value of a novel analytical approach to OGM that estimates individual trajectories of change over repeated trials.

  17. Balloon dilatation in children for oesophageal strictures other than those due to primary repair of oesophageal atresia, interposition or restrictive fundoplication

    International Nuclear Information System (INIS)

    Fasulakis, Stephen; Andronikou, Savvas

    2003-01-01

    Balloon dilatation of the oesophagus in children has been performed predominantly for treating strictures, which are the result of primary repair of oesophageal atresia, interposition surgery or restrictive Nissen's fundoplication. Reports of the use of this technique for alternative causes of stricture are few. To report our experience and success with balloon dilatation of strictures due to caustic ingestion, achalasia, oesophagitis, congenital stenosis, and epidermolysis bullosa (EB) and to make comparisons with our treatment of patients with primary repair of oesophageal atresia (OA), as well as with reports in the English language literature. Retrospective review of fluoroscopically guided balloon oesophageal dilatation procedures in 19 patients over a 5-year period, and comparison of those performed for OA repair complications with those due to other diseases. The average radiation dose, per procedure, was calculated by a medical physicist. Ten patients had strictures as a result of primary repair of OA. Three patients had stricture as a result of EB, two from achalasia, two from caustic injury, one due to an oesophageal web and one from reflux oesophagitis. Our results show that the technique can also be curative for the last group and that it may be used intermittently to alleviate symptoms in ongoing diseases. We have not experienced any complications and have also calculated that, even with prolonged use of multiple procedures, the radiation exposure is comparable to other radiological techniques. Patients with alternative causes for oesophageal stricture may be treated to resolution within 2 years using balloon dilatation. Ongoing diseases such as EB require ongoing dilatation, but balloon dilatation of strictures has been successful in alleviating swallowing difficulty. Patients with stricture from OA repair sometimes need ongoing dilatation. Radiation exposure for multiple procedures, over an extended period, is comparable to that from a single

  18. Balloon dilatation in children for oesophageal strictures other than those due to primary repair of oesophageal atresia, interposition or restrictive fundoplication

    Energy Technology Data Exchange (ETDEWEB)

    Fasulakis, Stephen [Royal Children' s Hospital, Melbourne (Australia); Andronikou, Savvas [Royal Children' s Hospital, Melbourne (Australia); Department of Paediatric Radiology, Red Cross Children' s Hospital, Klipfontein Road, Rondebosch, 7700, Cape Town (South Africa)

    2003-10-01

    Balloon dilatation of the oesophagus in children has been performed predominantly for treating strictures, which are the result of primary repair of oesophageal atresia, interposition surgery or restrictive Nissen's fundoplication. Reports of the use of this technique for alternative causes of stricture are few. To report our experience and success with balloon dilatation of strictures due to caustic ingestion, achalasia, oesophagitis, congenital stenosis, and epidermolysis bullosa (EB) and to make comparisons with our treatment of patients with primary repair of oesophageal atresia (OA), as well as with reports in the English language literature. Retrospective review of fluoroscopically guided balloon oesophageal dilatation procedures in 19 patients over a 5-year period, and comparison of those performed for OA repair complications with those due to other diseases. The average radiation dose, per procedure, was calculated by a medical physicist. Ten patients had strictures as a result of primary repair of OA. Three patients had stricture as a result of EB, two from achalasia, two from caustic injury, one due to an oesophageal web and one from reflux oesophagitis. Our results show that the technique can also be curative for the last group and that it may be used intermittently to alleviate symptoms in ongoing diseases. We have not experienced any complications and have also calculated that, even with prolonged use of multiple procedures, the radiation exposure is comparable to other radiological techniques. Patients with alternative causes for oesophageal stricture may be treated to resolution within 2 years using balloon dilatation. Ongoing diseases such as EB require ongoing dilatation, but balloon dilatation of strictures has been successful in alleviating swallowing difficulty. Patients with stricture from OA repair sometimes need ongoing dilatation. Radiation exposure for multiple procedures, over an extended period, is comparable to that from a single

  19. Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

    International Nuclear Information System (INIS)

    Fujita, Takeshi; Tanabe, Masahiro; Yamatogi, Shigenari; Shimizu, Kensaku; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57–93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 ± 13 (SD) min (range 24–78). The average follow-up time interval was 103 days (range 7–812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

  20. A Simulation Model for Drift Resistive Ballooning Turbulence Examining the Influence of Self-consistent Zonal Flows

    Science.gov (United States)

    Cohen, Bruce; Umansky, Maxim; Joseph, Ilon

    2015-11-01

    Progress is reported on including self-consistent zonal flows in simulations of drift-resistive ballooning turbulence using the BOUT + + framework. Previous published work addressed the simulation of L-mode edge turbulence in realistic single-null tokamak geometry using the BOUT three-dimensional fluid code that solves Braginskii-based fluid equations. The effects of imposed sheared ExB poloidal rotation were included, with a static radial electric field fitted to experimental data. In new work our goal is to include the self-consistent effects on the radial electric field driven by the microturbulence, which contributes to the sheared ExB poloidal rotation (zonal flow generation). We describe a model for including self-consistent zonal flows and an algorithm for maintaining underlying plasma profiles to enable the simulation of steady-state turbulence. We examine the role of Braginskii viscous forces in providing necessary dissipation when including axisymmetric perturbations. We also report on some of the numerical difficulties associated with including the axisymmetric component of the fluctuating fields. This work was performed under the auspices of the U.S. Department of Energy under contract DE-AC52-07NA27344 at the Lawrence Livermore National Laboratory (LLNL-ABS-674950).

  1. Test-retest repeatability of child's respiratory symptoms and perceived indoor air quality - comparing self- and parent-administered questionnaires.

    Science.gov (United States)

    Lampi, Jussi; Ung-Lanki, Sari; Santalahti, Päivi; Pekkanen, Juha

    2018-02-09

    Questionnaires can be used to assess perceived indoor air quality and symptoms in schools. Questionnaires for primary school aged children have traditionally been parent-administered, but self-administered questionnaires would be easier to administer and may yield as good, if not better, information. Our aim was to compare the repeatability of self- and parent-administered indoor air questionnaires designed for primary school aged pupils. Indoor air questionnaire with questions on child's symptoms and perceived indoor air quality in schools was sent to parents of pupils aged 7-12 years in two schools and again after two weeks. Slightly modified version of the questionnaire was administered to pupils aged 9-12 years in another two schools and repeated after a week. 351 (52%) parents and 319 pupils (86%) answered both the first and the second questionnaire. Test-retest repeatability was assessed with intra-class correlation (ICC) and Cohen's kappa coefficients (k). Test-retest repeatability was generally between 0.4-0.7 (ICC; k) in both self- and parent-administered questionnaire. In majority of the questions on symptoms and perceived indoor air quality test-retest repeatability was at the same level or slightly better in self-administered compared to parent-administered questionnaire. Agreement of self- and parent administered questionnaires was generally indoor air quality. Children aged 9-12 years can give as, or even more, repeatable information about their respiratory symptoms and perceived indoor air quality than their parents. Therefore, it may be possible to use self-administered questionnaires in future studies also with children.

  2. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  3. Delivering Acceptance and Commitment Therapy for Weight Self-Stigma through Guided Self-Help: Results from an Open Pilot Trial

    OpenAIRE

    Levin, Michael E.; Potts, Sarah; Haeger, Jack; Lillis, Jason

    2017-01-01

    Weight self-stigma is a promising target for innovative interventions seeking to improve outcomes among overweight/obese individuals. Preliminary research suggests acceptance and commitment therapy (ACT) may be an effective approach for reducing weight self-stigma, but a guided self-help version of this intervention may improve broad dissemination. This pilot open trial sought to evaluate the potential acceptability and efficacy of a guided self-help ACT intervention, included coaching and a ...

  4. Investigation of hot air balloon fatalities.

    Science.gov (United States)

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  5. Self expandable polytetrafluoroethylene stent for carotid blowout syndrome.

    Science.gov (United States)

    Tatar, E C; Yildirim, U M; Dündar, Y; Ozdek, A; Işik, E; Korkmaz, H

    2012-01-01

    Carotid blowout syndrome (CBS) is an emergency complication in patients undergoing treatment for head and neck cancers. The classical management of CBS is the ligation of the common carotid artery, because suturing is not be possible due to infection and necrosis of the field. In this case report, we present a patient with CBS, in whom we applied a self-expandable polytetrafluoroethylene (PTFE) stent and observed no morbidity. Endovascular stent is a life-saving technique with minimum morbidity that preserves blood flow to the brain. We believe that this method is preferable to ligation of the artery in CBS.

  6. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  7. Guiding College Students to Develop Academic Self-Regulatory Skills

    Science.gov (United States)

    Chen, Pin-Hwa

    2011-01-01

    This study aimed to explore the efficaciousness of a guiding model for Taiwanese college students employed to develop their academic self-regulatory skills. Twenty-eight undergraduates in a university in southern Taiwan were recruited as participants. The participants received training on the proposed guiding model and were asked to take their own…

  8. Transcatheter aortic value implantation with self-expandable nitinol valved stent: an experimental study in sheep

    International Nuclear Information System (INIS)

    Jiang Haibin; Huang Xinmiao; Bai Yuan

    2011-01-01

    Objective: to determine the feasibility and safety of transcatheter aortic valve implantation with domestic self-expandable nitinol valved stent in experimental sheep. Methods: A fresh pig pericardium was cross-linked with a 0.6% glutaraldehyde solution for 36 hours and then sutured on a nitinol self-expandable stent. Ten healthy sheep of (46.00±2.60) kg body weight were chosen for the study. Under general anesthesia, the device was delivered through catheter into the native aortic valve of the sheep via the femoral artery or abdominal aorta. The animals were followed up for three months. Results: Six devices were successfully delivered at the desired position in six sheep with no occurrence of complications. Angiographic and hemodynamic studies confirmed that the stents were fixed at correct position with competent valve function immediately and 90 days after the procedure. Technical failure or fatal complications occurred in the remaining four sheep. Conclusion: Implantation of a domestic nitinol self-expandable stent at the aortic valve position through a transcatheter approach is feasible in experimental sheep. (authors)

  9. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  10. Assessment of effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion using self-expanding Jaguar SM stents

    International Nuclear Information System (INIS)

    Kordecki, Kazimierz; Łukasiewicz, Adam; Nowicki, Mirosław; Lewszuk, Andrzej; Kowalewski, Radosław; Panek, Bogusław; Zawadzki, Michał; Michalak, Paweł; Gacko, Marek; Łebkowska, Urszula

    2012-01-01

    The goal of this work was to assess the effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion classified according to TASC using a self-expanding stent Jaguar SM. The study group included 95 patients (61 men and 34 women) who underwent treatment for stenosis or occlusion of lower limb arteries at the Department of Radiology of the University Hospital in Bialystok and the Diagnostic Radiology Department of the Central Clinical Hospital of the Ministry of Interior (MSWiA) in Warsaw between 2005 and 2007. All arterial lesions were of atherosclerotic etiology. The shortest stenotic fragment was 10 mm long and the longest occluded arterial fragment did not exceed 90 mm. Morphological classification of iliac artery lesions in treated patients was performed according to TASC II classification and included 10 patients with type A, 39 cases of type B, 36 with type C and 10 patients with type D lesions. Endovascular procedure failed to restore flow in five patients with TASC type D lesions, who were later referred for surgery. One patient suffered a complication – vessel perforation during predilatation, and had a stentgraft implanted. In 95% of patients stents were expanded using a balloon after implantation. Good results were achieved in practically all patients who underwent stent implantation. Patients were subjected to follow-up clinical and imaging evaluation during next 1–24 months. Success rate of the performed procedures as well as in a 30-day observation period was 100% in case of stenosis and 80% in case of vessel occlusion. A follow-up after 12 and 24 months showed patency of treated vessels in 84% and 76% of patients, respectively

  11. Trial of self-expandable metallic stents in the palliation of tracheo ...

    African Journals Online (AJOL)

    Trial of self-expandable metallic stents in the palliation of tracheo-oesophageal fistula in carcinoma of the oesophagus. ... Over half of the patients in the TOF group had concomitant pneumonia at presentation with decreased survival (p = 0.010) and a hazard ratio of 10.86. Two patients died, on days 4 and 7 respectively.

  12. Summer Reading Camp Self-Study Guide. REL 2015-070

    Science.gov (United States)

    Smith, Kevin G.; Foorman, Barbara R.

    2015-01-01

    This guide is designed to facilitate self-studies of planning and implementation of state-required summer reading camp programs for grade 3 students who scored at the lowest level on the state reading assessment. It provides a template for data collection and guiding questions for discussion that may improve instruction and increase the number of…

  13. Balloon Dilatation of Pediatric Subglottic Laryngeal Stenosis during the Artificial Apneic Pause: Experience in 5 Children

    Directory of Open Access Journals (Sweden)

    J. Lisý

    2014-01-01

    Full Text Available Introduction. Balloon dilatation is a method of choice for treatment of laryngeal stenosis in children. The aim of procedure in apneic pause is to avoid new insertion of tracheostomy cannula. Patients and Methods. The authors performed balloon dilatation of subglottic laryngeal strictures (SGS in 5 children (3 girls and 2 boys without tracheotomy. Two of them with traumatic and inflammatory SGS had a tracheal cannula removed in the past. The other 3 children with postintubation SGS had never had a tracheostomy before. The need for tracheostomy due to worsening stridor was imminent for all of them. Results. The total of seven laryngeal dilatations by balloon esophagoplasty catheter in apneic pause was performed in the 5 children. The procedure averted the need for tracheostomy placement in 4 of them (80%. Failure of dilatation in girl with traumatic stenosis and concomitant severe obstructive lung disease led to repeated tracheostomy. Conclusion. Balloon dilatation of laryngeal stricture could be done in the absence of tracheostomy in apneic pause. Dilatation averted threatening tracheostomy in all except one case. Early complication after the procedure seems to be a negative prognostic factor for the outcome of balloon dilatation.

  14. Direct Observation of Long-Range Transport Using Continuously Sounding Balloons and Near-Real-Time Trajectory Modeling

    Science.gov (United States)

    Voss, P. B.; Zaveri, R. A.; Berkowitz, C. M.

    2009-12-01

    Controlled Meteorological (CMET) balloons have been used in several recent studies to measure long-range transport over periods as long as 30 hours and distances up to 1000 kilometers. By repeatedly performing shallow soundings as they drift, CMET balloons can quantify evolving atmospheric structure, mixing events, shear advection, and dispersion during transport. In addition, the quasi-Lagrangian wind profiles can be used to drive a multi-layer trajectory model in which the advected air parcels follow the underlying terrain, or are constrained by altitude, potential temperature, or tracer concentration. Data from a coordinated balloon-aircraft study of long range transport over Texas (SETTS 2005) show that the reconstructed trajectories accurately track residual-layer urban outflow (and at times even its fine-scale structure) over distances of many hundreds of kilometers. The reconstructed trajectories and evolving profile visualizations are increasingly being made available in near-real time during balloon flights, supporting data-driven flight planning and sophisticated process studies relevant to atmospheric chemistry and climate. Multilayer trajectories (black grids) derived from CMET balloon flight paths (grey lines) for a transport event across Texas in 2005.

  15. Self-expanding metal stents in benign biliary strictures due to chronic pancreatitis

    NARCIS (Netherlands)

    van Berkel, A. M.; Cahen, D. L.; van Westerloo, D. J.; Rauws, E. A.; Huibregtse, K.; Bruno, M. J.

    2004-01-01

    Background and Study Aims: In selected patients with chronic pancreatitis in whom conventional plastic stenting fails and in whom surgery is contraindicated or declined, insertion of a biliary self-expanding metal stent (SEMS) may be a valuable treatment option. Patients and Methods: Between 1994

  16. Use of nitinol self-expandable stents in 26 dogs with tracheal collapse.

    Science.gov (United States)

    Beranek, J; Jaresova, H; Rytz, U

    2014-02-01

    A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

  17. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul

    2011-01-01

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 ± 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  18. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2011-07-15

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 {+-} 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  19. Implantation of modified Y-shaped self-expandable stent for the treatment of stenosis of gastroenteric stoma: preliminary results in five cases

    International Nuclear Information System (INIS)

    Wu Gang; Si Jiangtao; Han Xinwei; Jiao Dechao; Ding Pengxu; Fu Mingti; Li Zhen; Ma Ji

    2010-01-01

    Objective To investigate the feasibility and therapeutic effect of stenting therapy by using modified Y-shaped self-expandable metal stent for the stenosis of gastroenteric stoma. Methods: According to the particular anatomic structures and the pathological features of the narrowed gastroenteric stoma,the authors designed a modified Y-shaped self-expandable metal stent. Under the fluoroscopic guidance, implantation of modified Y-shaped self-expandable metal stent was performed in 5 patients with narrowed gastroenteric stoma. The technical safety and the clinical results were evaluated. Results: The modified Y-shaped self-expandable metal stent was successfully implanted with one procedure in all five patients. After the implantation the symptoms such as nausea, vomiting, abdominal distension were promptly relieved, and the patients' living quality was markedly improved. Conclusion: The stenting therapy with modified Y-shaped self-expandable metal stent can rapidly relieve the stenosis of gastroenteric stoma once for all. The technique is feasible and the short-term effect is reliable, therefore, it is worth popularizing this therapy in clinical practice. (authors)

  20. Use of retrievable self-expanding stent in treating childhood benign oesophageal stricture

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhu Ming

    2007-01-01

    Objective: To evaluate the methods and effect of retrievable self-expanding esophageal stent in treating benign esophageal stenosis of children. Methods: The covered retrievable expandable nitinol stents were placed in 10 children with corrosive esophageal stenosis and post-anastomotic stenosis, age ranged from 2 to 12 years, the dysphagia scores were 3, Barium esophagography was taken before the use of retrievable stent. Results: The stents were placed safely in all patients without complications and were successfully removed after all. After the stent placement, all patients could take solid food without dysphagia. During 6 to 12 months follow-up after the stent removal, all children could eat satisfactorily with the dysphagia score as 0. Conclusion: The use of covered retrievable expandable stent is effective and safe in treating childhood benign esophageal stenosis. (authors)

  1. Results of the new nitinol self-expandable stents for distal biliary structures

    NARCIS (Netherlands)

    Smits, M.; Huibregtse, K.; Tytgat, G.

    1995-01-01

    The nitinol stent is a self-expandable spiral stent made of nickel-titanium alloy. We performed a pilot study to evaluate the method of stent insertion and stent efficacy. Twenty-eight patients with irresectable malignancy had nitinol stents inserted for obstructive jaundice due to distal biliary

  2. Scientific Ballooning in India - Recent Developments

    Science.gov (United States)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  3. Self-guided Positive Imagery Training: Effects beyond the Emotions–A Loreta Study

    Directory of Open Access Journals (Sweden)

    Svetla Velikova

    2018-01-01

    Full Text Available Previously we demonstrated that a 12-week lasting self-guided positive imagery training had a positive effect on the psycho-emotional state of healthy subjects and was associated with an increase in functional connectivity in the brain. Here we repeated the previous project, but expanded the study, testing the hypothesis that training can also affect cognitive functions. Twenty subjects (half of them with subthreshold depression according CES-D participated in the program of positive imagery training for 12 weeks. The schedule began with group training for 2 days, followed by training at home. Evaluations of cognitive functions and electroencephalographic (EEG activity were conducted during three examinations as follows: E0-baseline (1 month before the training; E1-pre-training and E2-post-training. CNS Vital Signs battery was used to test the following cognitive domains: verbal and visual memory, executive functions, cognitive flexibility, social acuity, non-verbal reasoning. EEGs (19-channel were recorded at rest with closed eyes and analyzed with Low-resolution electromagnetic tomography software. One-way repeated measures ANOVA, followed by pairwise comparison showed a significant increase after training (E2 vs. E1; E2 vs. E0 in the number of correct hits for positive emotions received during perception of emotions test (POET; after the sample was split according to the initial presence of depressive symptoms, the effect was present only in the subgroup with subthreshold depressive symptomatology. Post-training (E2 vs. E1; E2 vs. E0 the number of correct answers on non-verbal reasoning test increased; this effect was observed only in the subgroup that does have any depressive symptoms. Comparison of EEG post-training vs. pre-training demonstrated a significant reduction in current source density (CSD after the training in the left hemisphere (insular cortex, frontal and temporal lobes in delta, theta and alpha1 bands. The observed changes

  4. Self-guided Positive Imagery Training: Effects beyond the Emotions–A Loreta Study

    Science.gov (United States)

    Velikova, Svetla; Nordtug, Bente

    2018-01-01

    Previously we demonstrated that a 12-week lasting self-guided positive imagery training had a positive effect on the psycho-emotional state of healthy subjects and was associated with an increase in functional connectivity in the brain. Here we repeated the previous project, but expanded the study, testing the hypothesis that training can also affect cognitive functions. Twenty subjects (half of them with subthreshold depression according CES-D) participated in the program of positive imagery training for 12 weeks. The schedule began with group training for 2 days, followed by training at home. Evaluations of cognitive functions and electroencephalographic (EEG) activity were conducted during three examinations as follows: E0-baseline (1 month before the training); E1-pre-training and E2-post-training. CNS Vital Signs battery was used to test the following cognitive domains: verbal and visual memory, executive functions, cognitive flexibility, social acuity, non-verbal reasoning. EEGs (19-channel) were recorded at rest with closed eyes and analyzed with Low-resolution electromagnetic tomography software. One-way repeated measures ANOVA, followed by pairwise comparison showed a significant increase after training (E2 vs. E1; E2 vs. E0) in the number of correct hits for positive emotions received during perception of emotions test (POET); after the sample was split according to the initial presence of depressive symptoms, the effect was present only in the subgroup with subthreshold depressive symptomatology. Post-training (E2 vs. E1; E2 vs. E0) the number of correct answers on non-verbal reasoning test increased; this effect was observed only in the subgroup that does have any depressive symptoms. Comparison of EEG post-training vs. pre-training demonstrated a significant reduction in current source density (CSD) after the training in the left hemisphere (insular cortex, frontal and temporal lobes in delta, theta and alpha1 bands). The observed changes were

  5. Malignant Gastroduodenal Obstruction: Treatment with Self-Expanding Uncovered Wallstent

    International Nuclear Information System (INIS)

    Gutzeit, Andreas; Binkert, Christoph A.; Schoch, Eric; Sautter, Thomas; Jost, Res; Zollikofer, Christoph L.

    2009-01-01

    Purpose: To retrospectively evaluate the clinical effectiveness of a self-expanding uncovered Wallstent in patients with malignant gastroduodenal obstruction. Materials and Methods: Under combined endoscopic and fluoroscopic guidance, 29 patients with a malignant gastroduodenal stenosis were treated with a self-expanding uncovered metallic Wallstent. A dysphagia score was assessed before and after the intervention to measure the success of this palliative therapy. The dysphagia score ranged between grade 0 to grade 4: grade 0 = able to tolerate solid food, grade 1 = able to tolerate soft food, grade 2 = able to tolerate thick liquids, grade 3 = able to tolerate water or clear fluids, and grade 4 = unable to tolerate anything perorally. Stent patency and patients survival rates were calculated. Results: The insertion of the gastroduodenal stent was technically successful in 28 patients (96.5%). After stenting, 25 patients (86.2%) showed clinical improvement by at least one score point. During follow-up, 22 (78.5%) of 28 patients showed no stent occlusion until death and did not have to undergo any further intervention. In six patients (20.6%), all of whom were treated with secondary stent insertions, occlusion with tumor ingrowth and/or overgrowth was observed after the intervention. The median period of primary stent patency in our study was 240 days. Conclusion: Placement of an uncovered Wallstent is clinically effective in patients with malignant gastroduodenal obstruction. Stent placement is associated with high technical success, good palliation effect, and high durability of stent function.

  6. A local network integrated into a balloon-borne apparatus

    Science.gov (United States)

    Imori, Masatosi; Ueda, Ikuo; Shimamura, Kotaro; Maeno, Tadashi; Murata, Takahiro; Sasaki, Makoto; Matsunaga, Hiroyuki; Matsumoto, Hiroshi; Shikaze, Yoshiaki; Anraku, Kazuaki; Matsui, Nagataka; Yamagami, Takamasa

    A local network is incorporated into an apparatus for a balloon-borne experiment. A balloon-borne system implemented in the apparatus is composed of subsystems interconnected through a local network, which introduces modular architecture into the system. The network decomposes the balloon-borne system into subsystems, which are similarly structured from the point of view that the systems is kept under the control of a ground station. The subsystem is functionally self-contained and electrically independent. A computer is integrated into a subsystem, keeping the subsystem under the control. An independent group of batteries, being dedicated to a subsystem, supplies the whole electricity of the subsystem. The subsystem could be turned on and off independently of the other subsystems. So communication among the subsystems needs to be based on such a protocol that could guarantee the independence of the individual subsystems. An Omninet protocol is employed to network the subsystems. A ground station sends commands to the balloon-borne system. The command is received and executed at the system, then results of the execution are returned to the ground station. Various commands are available so that the system borne on a balloon could be controlled and monitored remotely from the ground station. A subsystem responds to a specific group of commands. A command is received by a transceiver subsystem and then transferred through the network to the subsystem to which the command is addressed. Then the subsystem executes the command and returns results to the transceiver subsystem, where the results are telemetered to the ground station. The network enhances independence of the individual subsystems, which enables programs of the individual subsystems to be coded independently. Independence facilitates development and debugging of programs, improving the quality of the system borne on a balloon.

  7. Large-diameter balloon dilation for the treatment of achalasia of cardia: an analysis of mid-to-long term efficacy in 80 cases

    International Nuclear Information System (INIS)

    Song Jinwen; Yin Jianguo; Yang Yan; Liu Xiaohong; Wang Zhihong

    2011-01-01

    Objective: To discuss the technical points of large-diameter (40 mm) balloon dilation in treating achalasia of cardia, and to assess its mid-to-long term efficacy. Methods: A total of 80 patients of achalasia of cardia with a disease course of 3-23 years were enrolled in this study. According to Mellow-Pinkas standard of the dysphagia grading (from 0 to Ⅳ), the patients were classified into grade Ⅰ (n=6), grade Ⅱ (n=60) and grade Ⅲ (n=14). The diagnosis was confirmed by barium meal examination in all patients. Under spraying anesthesia of pharyngeal portion with 2% lidocaine, the intensified guide wire was inserted into the stomach through mouth under fluoroscopy guidance. The Boston's balloon (40 mm in diameter) was pushed along the guidewire to the stricture site at the cardia and was gradually inflated with 15% contrast medium by using the 'graded intermittent inflation' technique. Namely, the balloon was inflated to a maximum diameter and was kept in this condition for five minute, and then the balloon was deflated for 3-5 minutes. The above procedure was repeated 2-3 times. For the severe stricture, pre-dilatation with 20-25 mm diameter balloon was carried out. As a routine, postoperative measures to prevent possible bleeding and infection were adopted. The patient was allowed to take cool liquid diet 2-3 hours after the procedure, to have semi-liquid diet within three days and then to take normal diet. The patients were followed up for 2-10 years. Results: The balloon insertion was technically successful in all of the 80 patients. The success rate of single and twice manipulations was 96.3% (77/80) and 3.7% (3/80), respectively. Postoperative rupture of the cardia region was seen in one patient, and surgical repair had to be carried out. The follow-up time ranged from 2 years to 10 years (mean 6.27 years). No recurrent stenosis occurred in all patients. The remission rate of dysphagia was 100%. The swallowing function returned to normal in 90% of

  8. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Directory of Open Access Journals (Sweden)

    Ahmed Abdel Samie

    2012-01-01

    Full Text Available Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES, and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause.

  9. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Science.gov (United States)

    Abdel Samie, Ahmed; Theilmann, Lorenz

    2012-01-01

    Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs) have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES), and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause. PMID:22761543

  10. Towards a Knowledge Building Community: From Guided to Self-Organized Inquiry

    Directory of Open Access Journals (Sweden)

    Stefano Cacciamani

    2010-11-01

    Full Text Available Over four academic years a design experiment was conducted involving four online university courses with the goal of shifting from Guided to Self-Organized Inquiry to foster Knowledge Building communities in the classroom. Quantitative analyses focused on notes contributed to collective knowledge spaces, as well as reading and building-on notes of others. All team members, including teachers, contributed at high levels. Students tended to produce more notes in the guided-inquiry approach but read more and demonstrated more even distribution of work as part of self-organized inquiry. Qualitative data focused on strategies students reported as new to their school experience. Strategies fell into three categories common to both guided and self-organizing inquiry: elaborating course content for depth of understanding, collaboration in an online environment, and metacognition, with greater reflection on idea development. Distinctive aspects of self-organized inquiry, according to student reports, included going beyond given information, linking new understandings and personal experiences, attention to the collective works of the community, and learning from instructor’s strategies.

  11. Scientific ballooning in India Recent developments

    Science.gov (United States)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  12. Weather integration in TMC operations : a self-evaluation and planning guide.

    Science.gov (United States)

    2009-04-01

    This flyer describes how Traffic Management Centers (TMC) can integrate weather information into their daily operations, and is based on the Road Weather Management Program publication, Self-Evaluation and Planning Guide (FHWA-JPO-08-057). The Guide ...

  13. Identification of genes containing expanded purine repeats in the human genome and their apparent protective role against cancer.

    Science.gov (United States)

    Singh, Himanshu Narayan; Rajeswari, Moganty R

    2016-01-01

    Purine repeat sequences present in a gene are unique as they have high propensity to form unusual DNA-triple helix structures. Friedreich's ataxia is the only human disease that is well known to be associated with DNA-triplexes formed by purine repeats. The purpose of this study was to recognize the expanded purine repeats (EPRs) in human genome and find their correlation with cancer pathogenesis. We developed "PuRepeatFinder.pl" algorithm to identify non-overlapping EPRs without pyrimidine interruptions in the human genome and customized for searching repeat lengths, n ≥ 200. A total of 1158 EPRs were identified in the genome which followed Wakeby distribution. Two hundred and ninety-six EPRs were found in geneic regions of 282 genes (EPR-genes). Gene clustering of EPR-genes was done based on their cellular function and a large number of EPR-genes were found to be enzymes/enzyme modulators. Meta-analysis of 282 EPR-genes identified only 63 EPR-genes in association with cancer, mostly in breast, lung, and blood cancers. Protein-protein interaction network analysis of all 282 EPR-genes identified proteins including those in cadherins and VEGF. The two observations, that EPRs can induce mutations under malignant conditions and that identification of some EPR-gene products in vital cell signaling-mediated pathways, together suggest the crucial role of EPRs in carcinogenesis. The new link between EPR-genes and their functionally interacting proteins throws a new dimension in the present understanding of cancer pathogenesis and can help in planning therapeutic strategies. Validation of present results using techniques like NGS is required to establish the role of the EPR genes in cancer pathology.

  14. Self-expandable metal stent placement versus emergency resection for malignant proximal colon obstructions

    NARCIS (Netherlands)

    Amelung, F.J.; Draaisma, W.A.; Consten, E.C.; Siersema, P.D.; Borg, F. ter

    2017-01-01

    BACKGROUND: Traditionally, all patients with a malignant obstruction of the proximal colon (MOPC) are treated with emergency resection. However, recent data suggest that Self-expandable metallic stent (SEMS) placement could lower mortality and morbidity rates. This study therefore aimed to compare

  15. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  16. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  17. Comparative-Effectiveness of Simulation-Based Deliberate Practice Versus Self-Guided Practice on Resident Anesthesiologists' Acquisition of Ultrasound-Guided Regional Anesthesia Skills.

    Science.gov (United States)

    Udani, Ankeet Deepak; Harrison, T Kyle; Mariano, Edward R; Derby, Ryan; Kan, Jack; Ganaway, Toni; Shum, Cynthia; Gaba, David M; Tanaka, Pedro; Kou, Alex; Howard, Steven K

    2016-01-01

    Simulation-based education strategies to teach regional anesthesia have been described, but their efficacy largely has been assumed. We designed this study to determine whether residents trained using the simulation-based strategy of deliberate practice show greater improvement of ultrasound-guided regional anesthesia (UGRA) skills than residents trained using self-guided practice in simulation. Anesthesiology residents new to UGRA were randomized to participate in either simulation-based deliberate practice (intervention) or self-guided practice (control). Participants were recorded and assessed while performing simulated peripheral nerve blocks at baseline, immediately after the experimental condition, and 3 months after enrollment. Subject performance was scored from video by 2 blinded reviewers using a composite tool. The amount of time each participant spent in deliberate or self-guided practice was recorded. Twenty-eight participants completed the study. Both groups showed within-group improvement from baseline scores immediately after the curriculum and 3 months following study enrollment. There was no difference between groups in changed composite scores immediately after the curriculum (P = 0.461) and 3 months following study enrollment (P = 0.927) from baseline. The average time in minutes that subjects spent in simulation practice was 6.8 minutes for the control group compared with 48.5 minutes for the intervention group (P < 0.001). In this comparative effectiveness study, there was no difference in acquisition and retention of skills in UGRA for novice residents taught by either simulation-based deliberate practice or self-guided practice. Both methods increased skill from baseline; however, self-guided practice required less time and faculty resources.

  18. Complete electronics self-teaching guide with projects

    CERN Document Server

    Boysen, Earl

    2012-01-01

    An all-in-one resource on everything electronics-related! For almost 30 years, this book has been a classic text for electronics enthusiasts. Now completely updated for today's technology, this latest version combines concepts, self-tests, and hands-on projects to offer you a completely repackaged and revised resource. This unique self-teaching guide features easy-to-understand explanations that are presented in a user-friendly format to help you learn the essentials you need to work with electronic circuits. All you need is a general understanding of electronics concepts such as Oh

  19. Expandable metallic stents: An experimental study in the nasolacrimal systems of dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Lee, Jeong Min; Han, Young Min; Hwang, Eui Il; Chung, Gyung Ho; Shon, Myung Hee; Kim, Chong Soo; Choi, Ki Chul [Chonbuk National University Medical School, Chonju(Korea, Republic of)

    1993-11-15

    Balloon dacryocystoplasty has been reported to be a safe, easy and effective nonoperative treatment for nasolacrimal stenosis. The results were not encouraging, however, because of its high failure and recurrence rates. To evaluate the feasibility of using modified Gianturco expandable metallic stents for maintenance of the dilated nasolacrimal system(NLS), 20 stents of 3 mm in diameter and 10 mm long were placed in 20 nasolacrimal ducts of 10 dogs for 1 month to 10 months. It was more difficult to introduce the stents into the proximal portion(A) of the NLS than into the distal portion(B) due to the narrow and bony canal of the A portion. Twenty stents showed no migration in follow-up studies of up to 10 months. One complete occlusion occurred in a stent placed in A portion. Autopsy studies showed stents were covered with epithelium within 2 months after placement. Our experience suggest that the placement of Gianturco self-expandable stents may be a useful method of dilating and maintaining the luminal diameter of the NLS, although care must be taken to select the proper stent size.

  20. Expandable metallic stents: An experimental study in the nasolacrimal systems of dogs

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Jeong Min; Han, Young Min; Hwang, Eui Il; Chung, Gyung Ho; Shon, Myung Hee; Kim, Chong Soo; Choi, Ki Chul

    1993-01-01

    Balloon dacryocystoplasty has been reported to be a safe, easy and effective nonoperative treatment for nasolacrimal stenosis. The results were not encouraging, however, because of its high failure and recurrence rates. To evaluate the feasibility of using modified Gianturco expandable metallic stents for maintenance of the dilated nasolacrimal system(NLS), 20 stents of 3 mm in diameter and 10 mm long were placed in 20 nasolacrimal ducts of 10 dogs for 1 month to 10 months. It was more difficult to introduce the stents into the proximal portion(A) of the NLS than into the distal portion(B) due to the narrow and bony canal of the A portion. Twenty stents showed no migration in follow-up studies of up to 10 months. One complete occlusion occurred in a stent placed in A portion. Autopsy studies showed stents were covered with epithelium within 2 months after placement. Our experience suggest that the placement of Gianturco self-expandable stents may be a useful method of dilating and maintaining the luminal diameter of the NLS, although care must be taken to select the proper stent size

  1. Clinical application of self-expandable metallic stents in the treatment of malignant tracheal stenosis under general anesthesia

    International Nuclear Information System (INIS)

    Wang Weitao; Shi Haibin; Yang Zhengqiang; Liu Sheng; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun

    2009-01-01

    Objective: To evaluate the safety and efficacy of self-expandable metallic stent placement for the treatment of malignant tracheal stenosis under general anesthesia and fluoroscopic guidance. Methods: Under general anesthesia the placement of self-expandable metallic stent was performed in 10 patients with malignant tracheal stenosis, the procedure was completed under fluoroscopic guidance in all patients. Results: Successful tracheal stenting was achieved in all 10 patients. In one patient, a Y-shaped stent was used as the tracheal carina was involved in the airway stenosis. The symptoms of dyspnea and asthma were markedly improved immediately after the implantation of stent in all patients. Conclusion: Tracheal implantation of self-expandable metallic stent under general anesthesia and fluoroscopic guidance is a safe and effective treatment for malignant tracheal stenosis, it can promptly relieve various symptoms caused by malignant tracheal stenosis and obviously improve patient's living quality, therefore,t his technique is of great value in clinical practice. (authors)

  2. New treatment of iliac artery disease: focus on the Absolute Pro® Vascular Self-Expanding Stent System

    Directory of Open Access Journals (Sweden)

    Gates L

    2013-09-01

    Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease

  3. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  4. Oesophageal strictures caused by the ingestion of corrosive agents: effectiveness of balloon dilatation in children

    Energy Technology Data Exchange (ETDEWEB)

    Doo, E.-Y. [Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Shin, J.H. [Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of)], E-mail: jhshin@amc.seoul.kr; Kim, J.H.; Song, H.-Y. [Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of)

    2009-03-15

    Aim: To evaluate the safety and clinical effectiveness of balloon dilatation in children for oesophageal strictures caused by the ingestion of corrosive agents. Materials and methods: The study comprised 11 children (median age 6 years; range 1-14 years) with oesophageal strictures caused by corrosive agents, who underwent a total of 36 balloon dilatation sessions. The technical and clinical success, recurrence of dysphagia, complications, and primary and secondary patency rates were retrospectively evaluated. Results: Technical success was achieved in 91% of patients and in 97% of balloon dilatation sessions. Clinical success (defined as improved food intake and reduced dysphagia within 1 month of the first balloon dilatation session) was achieved in 64% of patients (7/11). During the mean 35-month follow-up period (range 1-89 months), 10 (91%) patients experienced recurrence. Oesophageal rupture (types 1 or 2) occurred in 45% of patients and in 31% of balloon dilatation sessions. Primary patency rates at 6 months and 1, 2, 3, 4, and 5 years were 36, 27, 14, 14, 14, and 14%, respectively. Secondary patency rates at 6 months and 1, 2, 3, 4, and 5 years were 82, 82, 82, 56, 42, and 42%, respectively. The secondary patency rate was higher than the primary patency rate (p < 0.05). Conclusion: The present study examined oesophageal balloon dilatation for paediatric oesophageal strictures caused by the ingestion of corrosive agents. Although the technical success rate was high and there were no deaths, the clinical success rate was low owing to a high recurrence rate. However, repeated balloon dilatations resulted in an acceptable secondary patency rate.

  5. Treatment of Pelvic Venous Spur (May-Thurner Syndrome) with Self-Expanding Metallic Endoprostheses

    International Nuclear Information System (INIS)

    Binkert, Christoph A.; Schoch, Eric; Stuckmann, Gerd; Largiader, Jon; Wigger, Pius; Schoepke, Wolfdietrich; Zollikofer, Christoph L.

    1998-01-01

    Purpose: The application of self-expanding metallic endoprostheses (stents) to treat symptomatic pelvic venous spurs as an alternative to surgery. Methods: Wallstents with a diameter from 14 to 16 mm and one Cragg stent were placed in the left common iliac vein of eight patients (seven women, one man; mean age 42 years) with a symptomatic pelvic venous spur (left deep venous thrombosis or post-thrombotic leg swelling). Four patients had surgical thrombectomy prior to stent placement. Results: Technical success with immediate reduction of left leg circumference was achieved in all eight patients. A primary patency rate of 100% was observed during an average follow-up of 3 years (range 10-121 months). There were no procedural or stent-related complications. Conclusion: The percutaneous transfemoral placement of self-expanding metallic stents is an effective minimally invasive alternative to surgery in the treatment of symptomatic pelvic venous spur

  6. Epitopes of MUC1 Tandem Repeats in Cancer as Revealed by Antibody Crystallography: Toward Glycopeptide Signature-Guided Therapy

    Directory of Open Access Journals (Sweden)

    Dapeng Zhou

    2018-05-01

    Full Text Available Abnormally O-glycosylated MUC1 tandem repeat glycopeptide epitopes expressed by multiple types of cancer have long been attractive targets for therapy in the race against genetic mutations of tumor cells. Glycopeptide signature-guided therapy might be a more promising avenue than mutation signature-guided therapy. Three O-glycosylated peptide motifs, PDTR, GSTA, and GVTS, exist in a tandem repeat HGVTSAPDTRPAPGSTAPPA, containing five O-glycosylation sites. The exact peptide and sugar residues involved in antibody binding are poorly defined. Co-crystal structures of glycopeptides and respective monoclonal antibodies are very few. Here we review 3 groups of monoclonal antibodies: antibodies which only bind to peptide portion, antibodies which only bind to sugar portion, and antibodies which bind to both peptide and sugar portions. The antigenicity of peptide and sugar portions of glyco-MUC1 tandem repeat were analyzed according to available biochemical and structural data, especially the GSTA and GVTS motifs independent from the most studied PDTR. Tn is focused as a peptide-modifying residue in vaccine design, to induce glycopeptide-binding antibodies with cross reactivity to Tn-related tumor glycans, but not glycans of healthy cells. The unique requirement for the designs of antibody in antibody-drug conjugate, bi-specific antibodies, and chimeric antigen receptors are also discussed.

  7. Self-guided internet-based and mobile-based stress management for employees

    DEFF Research Database (Denmark)

    Ebert, D. D.; Heber, E.; Berking, M.

    2016-01-01

    Objective This randomised controlled trial (RCT) aimed to evaluate the efficacy of a self-guided internet-based stress management intervention (iSMI) for employees compared to a 6-month wait-list control group (WLC) with full access for both groups to treatment as usual. M e t h o d A sample of 264...... of stressed employees. Internet-based self-guided interventions could be an acceptable, effective and potentially costeffective approach to reduce the negative consequences associated with work-related stress....

  8. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    International Nuclear Information System (INIS)

    Katsanos, Konstantinos; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 ± 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 ± 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 ± 9.1 %, lesion binary restenosis rate was 64.1 ± 8.3 %, and repeat intervention-free survival was 93.6 ± 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications

  9. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  10. Self-expanding stent-assisted middle cerebral artery recanalization: technical note

    International Nuclear Information System (INIS)

    Sauvageau, Eric; Levy, Elad I.

    2006-01-01

    Investigation into pharmacological and mechanical means of improving recanalization rates by intraarterial therapy has led to technological development. Angiographic recanalization has been associated with improvement in clinical outcome. A clot retriever has recently joined an imperfect armamentarium for intraarterial stroke therapy. In this report, we describe successful recanalization of an acute thrombotic occlusion of the inferior division of the middle cerebral artery (MCA) achieved with a self-expanding stent. An 82-year-old woman with a history of coronary atherosclerosis and previous cerebellar hemorrhage presented with a National Institutes of Health Stroke Scale (NIHSS) score of 11. Perfusion computed tomography imaging showed a left MCA territory deficit. Diffusion-weighted magnetic resonance (MR) imaging revealed a small punctiform insular hyperintensity. Angiography documented occlusion of the inferior division of the left MCA (Thrombolysis in Myocardial Infarction or Thrombolysis in Cerebral Infarction, TIMI/TICI, grade 0). Intraarterial delivery of eptifibatide to the occlusion site failed to recanalize the vessel. Deployment of a self-expanding stent in the occluded segment resulted in complete revascularization of the distal vascular bed. Angiography performed on the next day confirmed patency of the stented vessel segment (TIMI/TICI 3). The patient was discharged 3 days after the procedure (NIHSS 3). MR angiography obtained 3 months after the procedure documented left MCA patency. This technique may have a role worthy of further investigation in acute stroke therapy. (orig.)

  11. Listen to Me Listen to You: A Step-By-Step Guide to Communication Skills Training

    Science.gov (United States)

    Kotzman, Mandy; Kotzman, Anne

    2008-01-01

    This step-by-step guide is a companion to the popular "Listen to Me, Listen to You: A Practical Guide to Self-Awareness, Communication Skills and Conflict Management" (New Expanded Edition, Penguin Books, 2007). It is designed for use by anyone working in communication skills and personal development training. Resource material is grouped under…

  12. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  13. Self-Expanding Transcatheter Aortic Valve System for Symptomatic High-Risk Patients With Severe Aortic Stenosis

    DEFF Research Database (Denmark)

    Reichenspurner, Hermann; Schaefer, Andreas; Schäfer, Ulrich

    2017-01-01

    BACKGROUND: The CENTERA transcatheter heart valve (THV) is a low-profile, self-expanding nitinol valve made from bovine pericardial tissue that is 14-F compatible with a motorized delivery system allowing for repositionability. OBJECTIVES: The pivotal study evaluated safety and efficacy of this THV...... permanent pacemaker was implanted in 4.5% of patients receiving the THV (4.9% for patients at risk). CONCLUSIONS: The herein described THV is safe and effective at 30 days with low mortality, significant improvements in hemodynamic outcomes, and low incidence of adverse events. Of particular interest...... is the low incidence of permanent pacemaker implantations. (Safety and Performance Study of the Edwards CENTERA-EU Self-Expanding Transcatheter Heart Valve [CENTERA-2]; NCT02458560)....

  14. Self-Study Guide for Florida VPK Provider Improvement Plan Development

    Science.gov (United States)

    Phillips, Beth M.; Mazzeo, Debbie; Smith, Kevin

    2016-01-01

    This Self-Study Guide has been developed to support Florida Voluntary Prekindergarten Providers (VPK) who are required to complete an improvement plan process (i.e., low-performing providers). The guide has sections that can be used during both the process of selecting target areas for an improvement plan and the process of implementing new or…

  15. The Use of Guided Imagery as an Intervention in Addressing Nonsuicidal Self-Injury

    Science.gov (United States)

    Kress, Victoria E.; Adamson, Nicole; DeMarco, Carrie; Paylo, Matthew J.; Zoldan, Chelsey A.

    2013-01-01

    This article presents guided imagery as an intervention that can be used to address clients' nonsuicidal self-injurious behaviors. Guided imagery is a behavioral therapy technique that involves the use of positive thoughts or images to regulate negative emotional experiences, and it can be used to prevent and manage impulses to self-injure.…

  16. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    International Nuclear Information System (INIS)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K.

    2016-01-01

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  17. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    Energy Technology Data Exchange (ETDEWEB)

    Too, Chow Wei, E-mail: toochowwei@gmail.com [Singapore General Hospital (Singapore); Sayani, Raza [Aga Khan University Hospital (Pakistan); Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva [Singapore General Hospital (Singapore); Teo, Terence K. [Mount Elizabeth Novena Hospital (Singapore)

    2016-08-15

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  18. Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Yang Zhigang; Liu Jianmin; Xu Yi; Huang Qinghai; Hong Bo; Zhao Wenyuan; Zhao Rui

    2008-01-01

    Objective: To assess the value of a novel retrievable self-expanding stent system (LEO) in intracranial aneurysm treatment. Methods: 43 patients with 44 intracranial aneurysms treated with LEO stent were retrospectively analized, including 16 aneurysms with single-stent deployment, 25 with stent-assisted technique, 2 with double-stent deployment and one with double-stent assisted coils. Follow up was carried out through imaging and clinical course. Results: The stent was easy for repositioning and all the stents were delivered successfully, except 1 stent with unsatisfactory position, 1 with acute in-stent thrombosis. During follow up, 1 case showed chronic in-stent thrombus and one with intimal hyperplasia. 22 aneurysms got compact coiled during procedure. Among 29 follow up cases, 72.4% aneurysms were cured or improved, 13.8% were stable and three dissection aneurysms enlarged within short period and two patients died. Conclusion: The new retrievable self-expanding stent (LEO), with the advantages of controlled delivery, easy deployment and choice for various types is a valuable system for vascular reconstruction of intracranial aneurysm with thrombosis. (authors)

  19. Treating anxiety and depression in young adults: A randomised controlled trial comparing clinician-guided versus self-guided Internet-delivered cognitive behavioural therapy.

    Science.gov (United States)

    Dear, Blake F; Fogliati, Vincent J; Fogliati, Rhiannon; Johnson, Bareena; Boyle, Olivia; Karin, Eyal; Gandy, Milena; Kayrouz, Rony; Staples, Lauren G; Titov, Nickolai

    2017-10-01

    Internet-delivered cognitive behaviour therapy may increase access by young adults to evidence-based treatments for anxiety and depression. The aim of this study was to compare the efficacy of an Internet-delivered cognitive behaviour therapy intervention designed for adults aged 18-24 years, when delivered in clinician-guided versus self-guided formats. The intervention, the Mood Mechanic Course, is a transdiagnostic treatment that simultaneously targets symptoms of anxiety and depression using cognitive and behavioural skills. The brief intervention comprised four lessons, delivered over 5 weeks. Following a brief telephone interview, young adults ( n = 191) with symptoms of anxiety and depression were randomly allocated to either (1) clinician-guided treatment ( n = 96) or (2) self-guided treatment ( n = 95). At post treatment, large reductions (average improvement; clinician guided vs self-guided) were observed in symptoms of anxiety (44% vs 35%) and depression (40% vs 31%) in both groups. Significant improvements were also observed in general psychological distress (33% vs 29%), satisfaction with life (18% vs 15%) and disability (36% vs 29%). No marked or consistent differences in clinical outcomes emerged between conditions at post-treatment, at 3-month or 12-month follow-up. Satisfaction was high with both treatment formats, but slightly higher for clinician-guided treatment. These results indicate the potential of carefully developed Internet-delivered cognitive behaviour therapy interventions for young adults with anxiety and depression provided in either self or therapist-guided format. Further large-scale research is required to determine the short- and long-term advantages and disadvantages of different models of support.

  20. Self-designed femoral neck guide pin locator for femoral neck fractures.

    Science.gov (United States)

    Xia, Shengli; Wang, Ziping; Wang, Minghui; Wu, Zuming; Wang, Xiuhui

    2014-01-01

    Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle positioning and with general guide pin locator positioning provided by equipment manufacturers. The screw reset rate, screw parallelism, triangle area formed by the link line of the entry point of 3 guide pins, and maximum vertical load bearing of the femoral neck after internal fixation were recorded. As expected, the triangle area was largest in the self-designed positioning group, followed by the general positioning group and the freehand positioning group. The difference among the 3 groups was statistically significant (P.05). The authors’ self-designed guide pin positioning system has the potential to accurately insert cannulated screws in femoral neck fractures and may reduce bone loss and unnecessary radiation.

  1. Chemotherapy versus self-expanding metal stent as primary treatment of severe dysphagia from unresectable oesophageal or gastro-oesophageal junction cancer.

    Science.gov (United States)

    Touchefeu, Yann; Archambeaud, Isabelle; Landi, Bruno; Lièvre, Astrid; Lepère, Céline; Rougier, Philippe; Mitry, Emmanuel

    2014-03-01

    To compare chemotherapy first (group 1) versus self-expanding metal stent first (group 2) for the management of malignant dysphagia in unresectable oesophageal or gastro-oesophageal junction cancer. Patients from two university hospitals with severe malignant dysphagia (dysphagia score ≥ 2) uneligible for surgery or radiochemotherapy were evaluated retrospectively. Forty-two patients were included in group 1, and 29 in group 2. After 4 weeks, dysphagia scores improved by at least 1 point in 67% of patients in group 1 versus 93% in group 2 (p=0.01); 48% of patients in group 1 were able to eat solid food versus 68% in group 2 (p=0.054). In group 1, a self-expanding metal stent was secondarily placed in 18 patients (42.9%), whereas in group 2 dysphagia required a second self-expanding metal stent placement in 33.3% of patients. Chemotherapy as the first treatment may be a valid option, avoiding self-expanding metal stent insertion in half of the patients. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    Science.gov (United States)

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  3. Flame Speed and Self-Similar Propagation of Expanding Turbulent Premixed Flames

    Science.gov (United States)

    Chaudhuri, Swetaprovo; Wu, Fujia; Zhu, Delin; Law, Chung K.

    2012-01-01

    In this Letter we present turbulent flame speeds and their scaling from experimental measurements on constant-pressure, unity Lewis number expanding turbulent flames, propagating in nearly homogeneous isotropic turbulence in a dual-chamber, fan-stirred vessel. It is found that the normalized turbulent flame speed as a function of the average radius scales as a turbulent Reynolds number to the one-half power, where the average radius is the length scale and the thermal diffusivity is the transport property, thus showing self-similar propagation. Utilizing this dependence it is found that the turbulent flame speeds from the present expanding flames and those from the Bunsen geometry in the literature can be unified by a turbulent Reynolds number based on flame length scales using recent theoretical results obtained by spectral closure of the transformed G equation.

  4. Determination of balloon gas mass and revised estimates of drag and virtual mass coefficients

    Science.gov (United States)

    Robbins, E.; Martone, M.

    1993-01-01

    In support of the NASA Balloon Program, small-scale balloons were flown with varying lifting gas and total system mass. Instrument packages were developed to measure and record acceleration and temperature data during these tests. Top fitting and instrument payload accelerations were measured from launch to steady state ascent and through ballast drop transients. The development of the small lightweight self-powered Stowaway Special instrument packages is discussed along with mathematical models developed to determine gas mass, drag and virtual mass coefficients.

  5. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    Burnett, T.; Iwai, J.; Lord, J.J.; Strausz, S.; Wilkes, R.J.; Dake, S.; Oda, H.; Miyamura, O.; Fuki, M.; Jones, W.V.; Gregory, J.; Hayashi, T.; Takahashi, U.; Tominaga, Y.; Wefel, J.P.; Fountain, W.; Derrickson, J.; Parnell, T.A.; Roberts, E.; Tabuki, T.; Watts, J.W.

    1989-01-01

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  6. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    Directory of Open Access Journals (Sweden)

    Mohamed Shaker

    2016-09-01

    Conclusion: Fluoroscopic guided esophageal stenting is a highly effective and safe method for palliating dysphagia in patients with obstructing esophageal cancer with significant clinical improvement.

  7. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  8. Technologies developed by CNES balloon team

    Science.gov (United States)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  9. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report

    Directory of Open Access Journals (Sweden)

    Kumagai Hozumi

    2012-09-01

    Full Text Available Abstract Introduction Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient’s general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  10. Self-expandable metal stents for malignant colonic obstruction: data from a retrospective regional SIED-AIGO study.

    Science.gov (United States)

    Di Mitri, Roberto; Mocciaro, Filippo; Traina, Mario; Montalbano, Luigi Maria; Familiari, Luigi; D'Amore, Fabio; Raimondo, Dario; Virgilio, Clara; Tarantino, Ilaria; Barresi, Luca; Giunta, Marco; Borina, Eleonora; Borruto, Antonino; Marino, Antonino

    2014-03-01

    Self-expandable metal stents are a non-surgical option for the treatment of symptomatic malignant colorectal obstruction as palliative treatment or as a bridge to surgery. To report data from a regional study on self-expandable metal stent (SEMS) placement for malignant colorectal obstruction. Two hundred and four patients (male 54.9%, mean age of 69.5 ± 14.2) were retrospectively evaluated and data on technical and clinical success, and complications, were analyzed. Technical and clinical success rates were 99% and 94.6% respectively, with 36.7% treated on an emergency basis and 63.3% electively. Palliative treatment was administered to 70.1%, and as a bridge to surgery for 29.9%. Complications were 17 neoplastic ingrowths, 10 stent migrations, and 4 perforations. Palliative treatment was associated with a higher risk of stent ingrowth (p=0.003), and chemotherapy with a lower risk of stent ingrowth (p=0.009). This regional study, although it has certain limitations, confirms the positive role of self-expandable metal stents in the treatment of symptomatic malignant colorectal obstruction, and that chemotherapy decreases the risk of ingrowth. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Self-expandable metal stents for relieving malignant colorectal obstruction: short-term safety and efficacy within 30 days of stent procedure in 447 patients

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2011-01-01

    The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery.......The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery....

  12. Biodegradable shape-memory block co-polymers for fast self-expandable stents.

    Science.gov (United States)

    Xue, Liang; Dai, Shiyao; Li, Zhi

    2010-11-01

    Block co-polymers PCTBVs (M(n) of 36,300-65,300 g/mol, T(m) of 39-40 and 142 degrees C) containing hyperbranched three-arm poly(epsilon-caprolactone) (PCL) as switching segment and microbial polyester PHBV as crystallizable hard segment were designed as biodegradable shape-memory polymer (SMP) for fast self-expandable stent and synthesized in 96% yield by the reaction of three-arm PCL-triol (M(n) of 4200 g/mol, T(m) of 47 degrees C) with methylene diphenyl 4,4'-diisocyanate isocynate (MDI) to form the hyperbrached MDI-linked PCL (PTCM; M(n) of 25,400 g/mol and a T(m) of 38 degrees C), followed by further polymerization with PHBV-diol (M(n) of 2200 g/mol, T(m) of 137 and 148 degrees C). The polymers were characterized by (1)H NMR, GPC, DSC, tensile test, and cyclic thermomechanical tensile test. PCTBVs showed desired thermal properties, mechanical properties, and ductile nature. PCTBV containing 25 wt% PHBV (PCTBV-25) demonstrated excellent shape-memory property at 40 degrees C, with R(f) of 94%, R(r) of 98%, and shape recovery within 25s. PCTBV-25 was also shown as a safe material with good biocompatibility by cytotoxicity tests and cell growth experiments. The stent made from PCTBV-25 film showed nearly complete self-expansion at 37 degrees C within only 25 s, which is much better and faster than the best known self-expandable stents. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  13. GuideLiner™ as guide catheter extension for the unreachable mammary bypass graft.

    Science.gov (United States)

    Vishnevsky, Alec; Savage, Michael P; Fischman, David L

    2018-03-09

    Percutaneous coronary intervention (PCI) of mammary artery bypass grafts through a trans-radial (TR) approach can present unique challenges, including coaxial vessel engagement of the guiding catheter, adequate visualization of the target lesion, sufficient backup support for equipment delivery, and the ability to reach very distal lesions. The GuideLiner catheter, a rapid exchange monorail mother-in-daughter system, facilitates successful interventions in such challenging anatomy. We present a case of a patient undergoing PCI of a right internal mammary artery (RIMA) graft via TR access in whom the graft could not be engaged with any guiding catheter. Using a balloon tracking technique over a guidewire, a GuideLiner was placed as an extension of the guiding catheter and facilitated TR-PCI by overcoming technical challenges associated with difficult anatomy. © 2018 Wiley Periodicals, Inc.

  14. Efficacy of face-to-face versus self-guided treatments for disordered gambling: A meta-analysis.

    Science.gov (United States)

    Goslar, Martina; Leibetseder, Max; Muench, Hannah M; Hofmann, Stefan G; Laireiter, Anton-Rupert

    2017-06-01

    Background and aims In the light of growing traditional and novel forms of gambling, the treatment of disordered gambling is gaining increasing importance and practical relevance. Most studies have examined face-to-face treatments. Although trials implementing self-guided treatments have recently been conducted, these options have not yet been systematically examined. The primary objective of this meta-analysis, therefore, was to analyze the efficacy of all types of psychological face-to-face and self-guided treatments. Methods A multilevel literature search yielded 27 randomized controlled studies totaling 3,879 participants to provide a comprehensive comparative evaluation of the short- and long-term efficacies of face-to-face and self-guided treatments for disordered gambling. Results As expected, the results revealed significantly higher effect sizes for face-to-face treatments (16 studies with Hedges's g ranging from 0.67 to 1.15) as compared with self-guided treatments (11 studies with Hedges's g ranging from 0.12 to 0.30) regarding the reduction of problematic gambling behavior. The intensity of treatment moderated the therapy effect, particularly for self-guided treatments. Discussion and Conclusions The results of this meta-analysis favor face-to-face treatments over self-guided treatments for the reduction of disordered gambling. Although the findings broaden the scope of knowledge about psychological treatment modalities for disordered gambling, further research is needed to identify the reasons for these differences with the goal to optimize the treatment for this disabling condition.

  15. Two Tethered Balloon Systems

    Science.gov (United States)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  16. Biodegradable stents in benign stenosis of the esophagus

    International Nuclear Information System (INIS)

    Manova, G.

    2013-01-01

    Full text: Introduction: Benign stenosis of the esophagus can be postcorrosion peptic or postoperative. The treatment is difficult and traditionally consists of multiple dilatations. In refractory stenosis the placement of metal self-expanding stents is disputed because requiring their subsequent removal. New experience for therapeutic decision is self- degradable stents. Manipulation is a single and not requires their removal. What you will learn: Patients indicated for the treatment with self- degradable stents are with benign stenosis not suitable for balloon dilatation or bougienage dilation. The main groups are those with postcorrosion stenosis, peptic stenosis due to untreated gastroesophageal reflux disease with different prescription as well as post-surgical and post-radiation stenosis. Self-expanding stents made by monofilament polymer of polydioxanone, whose integrity and radial force remain 6-8 weeks depending on the gastric pH are used. Stents are applied in hard guide placed in the stenosis through the working channel of gastroscopy, and they are released under X-ray control. Putting is preceded by balloon dilatation due to the large diameter of the mounted stent. During the manipulations, several difficulties are encountered, which are missing in self-expanding metal stents. Discussion: Short-term results are satisfactory - Dysphagia in the patients is overcome and they recover their normal diet. The patients reported no pain. The control inspection of the 1st month showed partial degradation of the stents. On 3rd month it is set the complete degradation. Term follow-up shows resumption of dysphagia. Conclusion: Good short-term results make the use of self-degradable stents possible alternative for the treatment of the esophagus refractory stenosis. Long-term results are contradictory, still missing long enough randomized studies on this topic

  17. Recent Developments in Scientific Research Ballooning

    International Nuclear Information System (INIS)

    Jones, W. Vernon

    2007-01-01

    The National Aeronautics and Space Administration (NASA) Balloon Program is committed to meeting the need for extended duration scientific investigations by providing advanced balloon vehicles and support systems. A sea change in ballooning capability occurred with the inauguration of 8 - 20 day flights around Antarctica in the early 1990's. The attainment of 28-31 day flights and a record-breaking 42-day flight in, respectively, two and three circumnavigations of the continent has greatly increased the expectations of the scientific users. A new super-pressure balloon is currently under development for future flights of 60-100 days at any latitude, which would bring another sea change in scientific research ballooning

  18. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  19. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    Science.gov (United States)

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  20. Complication after self expandable metallic stent for esophageal cancer

    International Nuclear Information System (INIS)

    Nagahama, Takeshi; Maruyama, Michio; Kato, Kiyomi; Shinoura, Hiroshi; Hasegawa, Kumi; Takashima, Itaru; Ebuchi, Masakazu

    2003-01-01

    Major complications after placement of esophageal stent and airway stent were reviewed and evaluated. Four patients, including two patients with perforations and two patients with fistula formation, developed major complications after placement of a self expandable metallic stent. Two patients underwent additional radiation to improve stricture after stent placement. In one patient, stent placement was selected to improve esophageal stricture that occurred after radical radiation therapy. In one patient, migration of stent into the lesion caused a perforation. It can be concluded that additional radiation after stent placement increases the risk of complication. Stent migration also can lead to the risk of perforation. (author)

  1. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-06-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  2. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of Medicine, Masan (Korea, Republic of)

    2008-06-15

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction.

  3. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    International Nuclear Information System (INIS)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-01-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  4. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon; Ko, Ji Ho

    2008-01-01

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction

  5. Expanding Library Services and Instruction Through LibGuides.

    Science.gov (United States)

    Ream, Tim; Parker-Kelly, Darlene

    2016-01-01

    Beginning in 2012, the Charles R. Drew University (CDU) Health Sciences Library used LibGuides in a number of innovative ways. Librarians constructed e-book databases, in-depth tutorials on technology-related topics, and web pages highlighting special events. To assess similar LibGuides innovation, CDU librarians developed an eight-question survey distributed to health sciences and hospital libraries throughout Southern California and Arizona. Results showed that libraries used LibGuides primarily to deliver access to online resources and to provide supplementary materials supporting instruction. Responses also revealed that many libraries had not yet adopted LibGuides. These findings were analyzed and compared to past and current LibGuides design at CDU.

  6. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  7. Enhancement of Self Efficacy of Vocational School Students in Buffer Solution Topics through Guided Inquiry Learning

    Science.gov (United States)

    M, Ardiany; W, Wahyu; A, Supriatna

    2017-09-01

    The more students who feel less confident in learning, so doing things that are less responsible, such as brawl, drunkenness and others. So researchers need to do research related to student self efficacy in learning, in order to reduce unwanted things. This study aims to determine the effect of guided inquiry learning on improving self-efficacy of learners in the buffer solution topics. The method used is the mixed method which is the two group pretest postest design. The subjects of the study are 60 students of class XI AK in one of the SMKN in Bandung, consisting of 30 experimental class students and 30 control class students. The instruments used in this study mix method consist of self-efficacy questionnaire of pretest and posttest learners, interview guides, and observation sheet. Data analysis using t test with significant α = 0,05. Based on the result of inquiry of guided inquiry study, there is a significant improvement in self efficacy aspect of students in the topic of buffer solution. Data of pretest and posttest interview, observation, questionnaire showed significant result, that is improvement of experimental class with conventionally guided inquiry learning. The mean of self-efficacy of student learning there is significant difference of experiment class than control class equal to 0,047. There is a significant relationship between guided inquiry learning with self efficacy and guided inquiry learning. Each correlation value is 0.737. The learning process with guided inquiry is fun and challenging so that students can expose their ideas and opinions without being forced. From the results of questionnaires students showed an attitude of interest, sincerity and a good response of learning. While the results of questionnaires teachers showed that guided inquiry learning can make students learn actively, increased self-efficacy.

  8. Nonsurgical Fluoroscopically Guided Dacryocystoplasty of Common Canalicular Obstructions

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, Kai E; Hofer, Ulrich; Textor, Hans J [Department of Radiology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Boeker, Thorsten [Department of Ophthalmology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Strunk, Holger; Schild, Hans H [Department of Radiology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany)

    2000-01-15

    Purpose: To assess dacryocystoplasty in the treatment of epiphora due to obstructions of the common canaliculus.Methods: Twenty patients with severe epiphora due to partial (n = 16) or complete (n = 4) obstruction of the common canaliculus underwent fluoroscopically guided dacryocystoplasty. In all cases of incomplete obstruction balloon dilation was performed. Stent implantation was attempted in cases with complete obstruction. Dacryocystography and clinical follow-up was performed at intervals of 1 week, and 3, 6, 12, and 18 months after the procedure. The mean follow-up was 6 months (range 3-18 months).Results: Balloon dilation was technically successfully performed in all patients with incomplete obstructions (n = 16). In three of four patients with complete obstruction stent implantation was performed successfully. Subsequent to failure of stent implantation in one of these patients balloon dilation was performed instead. The long-term primary patency rate in patients with incomplete obstructions was 88% (n = 14/16). In three of four cases with complete obstruction long-term patency was achieved during follow-up. Severe complications, infections, or punctal splitting were not observed.Conclusion: Fluoroscopically guided balloon dacryocystoplasty is a feasible nonsurgical therapy in canalicular obstructions with good clinical results that may be used as an alternative to surgical procedures. In patients with complete obstructions stent placement is possible but further investigations are needed to assess the procedural and long-term results.

  9. Nonsurgical Fluoroscopically Guided Dacryocystoplasty of Common Canalicular Obstructions

    International Nuclear Information System (INIS)

    Wilhelm, Kai E.; Hofer, Ulrich; Textor, Hans J.; Boeker, Thorsten; Strunk, Holger; Schild, Hans H.

    2000-01-01

    Purpose: To assess dacryocystoplasty in the treatment of epiphora due to obstructions of the common canaliculus.Methods: Twenty patients with severe epiphora due to partial (n = 16) or complete (n = 4) obstruction of the common canaliculus underwent fluoroscopically guided dacryocystoplasty. In all cases of incomplete obstruction balloon dilation was performed. Stent implantation was attempted in cases with complete obstruction. Dacryocystography and clinical follow-up was performed at intervals of 1 week, and 3, 6, 12, and 18 months after the procedure. The mean follow-up was 6 months (range 3-18 months).Results: Balloon dilation was technically successfully performed in all patients with incomplete obstructions (n = 16). In three of four patients with complete obstruction stent implantation was performed successfully. Subsequent to failure of stent implantation in one of these patients balloon dilation was performed instead. The long-term primary patency rate in patients with incomplete obstructions was 88% (n = 14/16). In three of four cases with complete obstruction long-term patency was achieved during follow-up. Severe complications, infections, or punctal splitting were not observed.Conclusion: Fluoroscopically guided balloon dacryocystoplasty is a feasible nonsurgical therapy in canalicular obstructions with good clinical results that may be used as an alternative to surgical procedures. In patients with complete obstructions stent placement is possible but further investigations are needed to assess the procedural and long-term results

  10. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  11. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  12. Solar research with stratospheric balloons

    Science.gov (United States)

    Vázquez, Manuel; Wittmann, Axel D.

    Balloons, driven by hot air or some gas lighter than air, were the first artificial machines able to lift payloads (including humans) from the ground. After some pioneering flights the study of the physical properties of the terrestrial atmosphere constituted the first scientific target. A bit later astronomers realized that the turbulence of the atmospheric layers above their ground-based telescopes deteriorated the image quality, and that balloons were an appropriate means to overcome, total or partially, this problem. Some of the most highly-resolved photographs and spectrograms of the sun during the 20th century were actually obtained by balloon-borne telescopes from the stratosphere. Some more recent projects of solar balloon astronomy will also be described.

  13. Removal of self expandable metallic airway stent: A rare case report

    OpenAIRE

    Chawla, Rakesh K.; Madan, Arun; Singh, Ishwar; Mudoiya, Rahul; Chawla, Aditya; Gupta, Radha; Chawla, Kiran; Chhabra, Roopam

    2013-01-01

    Covered self expandable metallic airway stents (SEMS) have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after p...

  14. Abdominal cavity balloon for preventing a patient's bleeding

    OpenAIRE

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po sitioning the balloon.

  15. Comparison of visibility for four self-expanding nitinol bare stents in vitro

    International Nuclear Information System (INIS)

    Wiesinger, Benjamin; Stutz, Alexander; Schmehl, Joerg; Groezinger, Gerd; Claussen, Claus Detlef; Wiskirchen, Jakub

    2012-01-01

    Background Sufficient radiopacity of stents is a prerequisite for safe interventions and minimization of the radiation dose for the patient and the interventionist. Modern nitinol stents are considered less radiopaque compared to formerly used stents. Purpose To evaluate the objective detection rate (ODR) and the subjective radiopacity score (SRS) of four self-expanding nitinol stents with their markers on a phantom human pelvis. Material and Methods We evaluated the ODR (as a percentage of correctly identified stents) and the SRS (on a scale from 0 = not visible to 4 = excellent visibility) for four self-expanding nitinol stents (SinusSuperflex, SMART, Luminexx, Zilver) with 8 mm diameter and 40 mm length. Stents were placed on a phantom human pelvis and images of the stents were taken in four different positions (right and left lumbosacral joint and near the right and left limbus acetabuli) using the following modes: spotfilm, pulsed fluoroscopy (4, 7.5, 15, and 30 pulses/min) and at three different digital magnification modes. Dose area products (DAPs) were assessed. Results ODR and SRS, respectively, were significantly increased for the SMART stent compared to all other tested stents (P < 0.05): SMART 93.53% and 2.43, SinusSuperflex 90.81% and 2.21, Luminexx 90.39% and 2.20, and Zilver 89.28% and 2.21. ODR was significantly reduced in position 3 where the bone overlap was more pronounced for all stents (detection rates 77.14-79.56%). An increase in magnification significantly improved the ODR and SRS for all stents (70.33-99.25% and 1.07-3.28, respectively, P < 0.05). Increased pulsing frequency did not improve the ODR of the various stents but did increase the DAP. Conclusion The SMART stent had the best overall performance. In the presence of bone overlap, all self-expanding nitinol stents had poor results. Increased pulsing frequency did not improve ODR or SRS but did increase the DAP. Use of digital magnification modes had no effect on DAP increasing ODR

  16. Repeatability & Workability Evaluation of SIGMOD 2009

    KAUST Repository

    Manegold, Stefan

    2010-12-15

    SIGMOD 2008 was the first database conference that offered to test submitters\\' programs against their data to verify the repeatability of the experiments published [1]. Given the positive feedback concerning the SIGMOD 2008 repeatability initiative, SIGMOD 2009 modified and expanded the initiative with a workability assessment.

  17. Repeatability & Workability Evaluation of SIGMOD 2009

    KAUST Repository

    Manegold, Stefan; Manolescu, Ioana; Afanasiev, Loredana; Feng, Jieling; Gou, G.; Hadjieleftheriou, Marios; Harizopoulos, Stavros; Kalnis, Panos; Karanasos, Konstantinos; Laurent, Dominique; Lupu, M.; Onose, N.; Ré , C.; Sans, Virginie; Senellart, Pierre; Wu, T.; Shasha, Dennis E.

    2010-01-01

    SIGMOD 2008 was the first database conference that offered to test submitters' programs against their data to verify the repeatability of the experiments published [1]. Given the positive feedback concerning the SIGMOD 2008 repeatability initiative, SIGMOD 2009 modified and expanded the initiative with a workability assessment.

  18. Calculating Payload for a Tethered Balloon System

    Science.gov (United States)

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  19. Self-Guiding of Ultrashort Relativistically Intense Laser Pulses to the Limit of Nonlinear Pump Depletion

    International Nuclear Information System (INIS)

    Ralph, J. E.; Marsh, K. A.; Pak, A. E.; Lu, W.; Clayton, C. E.; Fang, F.; Joshi, C.; Tsung, F. S.; Mori, W. B.

    2009-01-01

    A study of self-guiding of ultra short, relativistically intense laser pulses is presented. Here, the laser pulse length is on the order of the nonlinear plasma wavelength and the normalized vector potential is greater than one. Self-guiding of ultrashort laser pulses over tens of Rayliegh lengths is possible when driving a highly nonlinear wake. In this case, self-guiding is limited by nonlinear pump depletion. Erosion of the pulse due to diffraction at the head of the laser pulse is minimized for spot sizes close to the blow-out radius. This is due to the slowing of the group velocity of the photons at the head of the laser pulse. Using an approximately 10 TW Ti:Sapphire laser with a pulse length of approximately 50 fs, experimental results are presented showing self-guiding over lengths exceeding 30 Rayliegh lengths in various length Helium gas jets. Fully explicit 3D PIC simulations supporting the experimental results are also presented.

  20. Square Stent: A New Self-Expandable Endoluminal Device and Its Applications

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Uchida, Barry; Timmermans, Hans; Keller, Frederick S.; Roesch, Josef

    2001-01-01

    The square stent is a new, simply constructed, self-expanding device that has recently been described. Compared with other stents, the square stent has a minimal amount of metal and thus requires a smaller-diameter catheter for introduction. Despite the small amount of metal present, the square stent has adequate expansile force. We have been evaluating the square stent for various interventional applications. In addition to the basic square stent, combinations of square stents and coverings for square stents were developed and evaluated to expand its uses and indications. One of the coverings tested is a new biomaterial: small intestinal submucosa (SIS). This paper will discuss the various applications of the square stent, which include a retrievable inferior vena cava filter, vascular occluder, graft adapter, and venous and aortic valves. In addition, we will review the important properties of SIS as a covering for the square stent

  1. Ballooning stable high beta tokamak equilibria

    International Nuclear Information System (INIS)

    Tuda, Takashi; Azumi, Masafumi; Kurita, Gen-ichi; Takizuka, Tomonori; Takeda, Tatsuoki

    1981-04-01

    The second stable regime of ballooning modes is numerically studied by using the two-dimensional tokamak transport code with the ballooning stability code. Using the simple FCT heating scheme, we find that the plasma can locally enter this second stable regime. And we obtained equilibria with fairly high beta (β -- 23%) stable against ballooning modes in a whole plasma region, by taking into account of finite thermal diffusion due to unstable ballooning modes. These results show that a tokamak fusion reactor can operate in a high beta state, which is economically favourable. (author)

  2. Scientific ballooning. Proceedings of the symposium on the scientific use of balloons and related technical problems, Innsbruck, Austria, May 29-June 10, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Riedler, W

    1979-01-01

    The book includes works on operational and technical aspects of balloon launching I and II, cooperative balloon campaigns, and new developments in scientific use of balloons. The specific topics discussed are coordinated balloon and rocket measurements of stratospheric wind shears and turbulence, ballooning in Japan and India, magnetospheric processes investigated with data taken from balloon flights, and remote sensing of middle atmosphere winds from balloon platforms.

  3. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  4. Two lighter than air systems in opposing flight regimes: An unmanned short haul, heavy load transport balloon and a manned, light payload airship

    Science.gov (United States)

    Pohl, R. A.

    1975-01-01

    Lighter Than Air vehicles are generally defined or categorized by the shape of the balloon, payload capacity and operational flight regime. Two balloon systems that are classed as being in opposite categories are described. One is a cable guided, helium filled, short haul, heavy load transport Lighter Than Air system with a natural shaped envelope. The other is a manned, aerodynamic shaped airship which utilizes hot air as the buoyancy medium and is in the light payload class. While the airship is in the design/fabrication phase with flight tests scheduled for the latter part of 1974, the transport balloon system has been operational for some eight years.

  5. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  6. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  7. Early Cosmic Ray Research with Balloons

    Science.gov (United States)

    Walter, Michael

    2013-06-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  8. Early Cosmic Ray Research with Balloons

    International Nuclear Information System (INIS)

    Walter, Michael

    2013-01-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster

  9. Self-guiding of high-intensity laser pulses for laser wake field acceleration

    International Nuclear Information System (INIS)

    Umstader, D.; Liu, X.

    1992-01-01

    A means of self-guiding an ultrashort and high-intensity laser pulse is demonstrated both experimentally and numerically. Its relevance to the laser wake field accelerator concept is discussed. Self-focusing and multiple foci formation are observed when a high peak power (P>100 GW), 1 μm, subpicosecond laser is focused onto various gases (air or hydrogen). It appears to result from the combined effects of self-focusing by the gas, and de-focusing both by diffraction and the plasma formed in the central high-intensity region. Quasi-stationary computer simulations show the same multiple foci behavior as the experiments. The results suggest much larger nonlinear electronic susceptibilities of a gas near or undergoing ionization in the high field of the laser pulse. Although self-guiding of a laser beam by this mechanism appears to significantly extend its high-intensity focal region, small-scale self-focusing due to beam non-uniformity is currently a limitation

  10. Astronomy: A Self-Teaching Guide, 6th Edition

    Science.gov (United States)

    Moché, Dinah L.

    2004-02-01

    "A lively, up-to-date account of the basic principles of astronomy and exciting current field of research."-Science Digest For a quarter of a century, Astronomy: A Self-Teaching Guide has been making students and amateur stargazers alike feel at home among the stars. From stars, planets and galaxies, to black holes, the Big Bang and life in space, this title has been making it easy for beginners to quickly grasp the basic concepts of astronomy for over 25 years. Updated with the latest discoveries in astronomy and astrophysics, this newest edition of Dinah Moché's classic guide now includes many Web site addresses for spectacular images and news. And like all previous editions, it is packed with valuable tables, charts, star and moon maps and features simple activities that reinforce readers' grasp of basic concepts at their own pace, as well as objectives, reviews, and self-tests to monitor their progress. Dinah L. Moché, PhD (Rye, NY), is an award-winning author, educator, and lecturer. Her books have sold over nine million copies in seven languages.

  11. Less invasive causal treatment of ejaculatory duct obstruction by balloon dilation: a case report, literature review and suggestion of a CT- or MRI-guided intervention

    Directory of Open Access Journals (Sweden)

    Ole Kayser

    2012-03-01

    Full Text Available Uni- or bilateral ejaculatory duct obstruction (EDO is a rare but correctable cause of infertility, chronic pelvic pain and postejaculatory pain. EDO is a congenital or acquired condition, it is the underlying cause of infertility in approximately 5% of infertile men. If acquired, the etiology often remains unresolved, but prostatitis or urethritis with post-inflammatory adhesion of the duct walls seems to be a common underlying pathomechanism. Although a certain constellation of physicochemical semen parameters may lead to correct diagnosis, EDO often resembles a diagnosis by exclusion. Imaging of acquired EDO remains a challenge and the established surgical therapy, transurethral resection of the ejaculatory ducts (TURED, leads to a low rate of natural conception and a high rate of complications such as reflux of urine and epididymitis. We present a case of a male with suspected EDO who underwent a combined approach to both, semi-invasive diagnosis and therapy by transrectal puncture of the seminal vesicles and antegrade balloon-dilation of the ejaculatory ducts. Possibilities and pitfalls of this procedure are described and the literature is reviewed. Furthermore, we suggest a CT- or MRI-guided, percutaneous intervention for treatment of ejaculatory duct obstruction by balloon dilation and demonstrate initial steps of this procedure with a body donor. We call this new procedure PTED (percutaneous transgluteal ejaculatory ductoplasty.

  12. Extensive caustic esophageal stricture in children can be treated by serial dilatations interspersed with silicone-covered nitinol stenting

    Directory of Open Access Journals (Sweden)

    Veronica Alonso

    2016-01-01

    Full Text Available Recurrent esophageal stenosis secondary to caustic ingestion may be challenging to treat. Self-expandable esophageal stents may be an alternative to repetitive endoscopic esophageal dilatation. We report a case of a 2-year-old male child with an extensive esophageal caustic stricture successfully treated using a combination of endoscopic dilatation and stenting. After 5 months of serial balloon dilatations, three nitinol internal silicone covered self-expandable stents were placed through the patient′s gastrostomy spanning the entire esophagus. The stents were positioned using a combination of both endoscopic and fluoroscopic guidance. The procedure was repeated with only one stent 3 months later. A new stricture in the proximal esophagus needed surgical resection and anastomosis, followed by two pneumatic dilatations with progressively longer asymptomatic intervals. The results are promising with the patient able to use his own esophagus; however, this is a single case and optimal stent standing time is still to be determined.

  13. Full covered self-expandable metal stents for the treatment of anastomotic leak using a silk thread.

    Science.gov (United States)

    Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Park, Su Bum; Kim, Su Jin; Hwang, Sun Hwi; Lee, Si Hak

    2017-07-01

    To evaluate the safety and effectiveness of fixation of the fully covered self-expandable metal stent (SEMS) placement using a silk thread for complete closure of an anastomotic leak. An anastomotic leak is a life-threatening complication after gastrectomy. Although the traditional treatment of choice was surgical re-intervention, an endoscopic SEMS can be used alternatively.During the study period, we retrospectively reviewed consecutive patients who received a modified covered SEMS capable of being fixed using a silk thread (Shim technique) due to an anastomotic leak after gastrectomy to prevent stent migration. Demographic data, stent placement and removal, clinical success, time to resolution, and complications were evaluated.A total of 7 patients underwent fully covered SEMS with a silk thread placement for an anastomotic leak after gastrectomy to treat gastric cancer. The patients' mean age was 71.3 ± 8.0 years. Man sex was predominant (85.7%). All patients' American Society of Anesthesiologists (ASA) scores were between I and III. Total gastrectomy was performed in 5 patients (71.4%) and proximal gastrectomy was performed in 2 patients (28.6%). The time between gastrectomy and stent insertion was 22.3 ± 11.1 days. The size of the leaks was 27.1 ± 11.1 mm. Technical success and complete leak closure were achieved in all patients. Stent migration was absent. All stents were removed between 4 and 6 weeks. Delayed esophageal stricture was found in 1 patient (14.2) and successfully resolved after endoscopic balloon dilation.For an anastomotic leak after gastrectomy, fully covered SEMS placement with a silk thread is an effective and safe treatment option without stent migration. The stent extraction time between 4 and 6 weeks was optimal without severe complications.

  14. Effect of guided relaxation and imagery on falls self-efficacy: a randomized controlled trial.

    Science.gov (United States)

    Kim, Bang Hyun; Newton, Roberta A; Sachs, Michael L; Glutting, Joseph J; Glanz, Karen

    2012-06-01

    To examine the effects of guided relaxation and imagery (GRI) on improvement in falls self-efficacy in older adults who report having a fear of falling. Randomized, controlled trial with allocation to GRI or guided relaxation with music of choice. General community. Ninety-one men and women aged 60 to 92. Participants were randomized to listen to a GRI audio compact disk (intervention group) or a guided relaxation audio compact disk and music of choice (control group) twice a week for 6 weeks for 10 minutes per session. Primary outcome measure was the Short Falls Efficacy Scale-International (FES-I). Secondary outcome measures were the Leisure Time Exercise Questionnaire (LTEQ) and the Timed Up and Go (TUG) mobility test. GRI participants reported greater improvements on the Short FES-I (P = .002) and LTEQ (P = .001) scores and shorter time on the TUG (P = .002) than the guided relaxation and music-of-choice group. GRI was more effective at increasing falls self-efficacy and self-reported leisure time exercise and reducing times on a simple mobility test than was guided relaxation with music of choice. GRI is an effective, simple, low-cost tool for older adults to improve falls self-efficacy and leisure time exercise behaviors. © 2012, Copyright the Authors Journal compilation © 2012, The American Geriatrics Society.

  15. Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Patel, Rakesh R.; Orton, Nigel; Tome, Wolfgang A.; Chappell, Rick; Ritter, Mark A.

    2003-01-01

    , respectively. Averaged over all conditions, inflation of the rectal balloon resulted in a significant reduction in rectal volume receiving ≥65 Gy to a mean ratio of 0.61 (P=0.01) or, in other words, a mean fractional high dose rectal sparing of 39%. There was a slight overall increase to 1.13 in the relative volume of bladder receiving at least 65 Gy; however, this was not significant (P=0.6). Use of an endorectal balloon with a non-image-guided 3D-CRT plan produced about as much rectal dose sparing as a highly conformal, image-guided IMRT approach without a balloon. However, inclusion of a balloon with IMRT produced further rectal sparing still. Conclusion: These results indicate that use of a rectal balloon with a 3D-CRT plan incorporating typical treatment margins will produce significant high dose rectal sparing that is comparable to that achieved by a highly conformal IMRT with ultrasound localization. Further sparing is achieved with the inclusion of a balloon catheter in an IMRT plan. Thus, in addition to a previously reported advantage of prostate immobilization, the use of a rectal displacement balloon during daily treatment results in high dose rectal wall sparing during both modestly and highly conformal radiotherapy. Such sparing could assist in controlling and limiting rectal toxicity during increasingly aggressive dose escalation

  16. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  17. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  18. Outcome of self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer

    International Nuclear Information System (INIS)

    Jin Jing; Gao Li; Yu Zihao; Han Jianzhu; Zhai Renyou

    2007-01-01

    Objective: To retrospectively analyze the efficacy for self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer. Methods: From Jan 1996 to Sep 2002, 17 patients were treated with self-expanding metal stenting followed by Ir 192 high dose brachytherapy (brachytherapy group, n=5)and by external beam radiation therapy(external radiation therapy group, n=9). Brachytherapy was delivered on the same day or the following day after stenting with the total dose of DT 20- 30 Gy, twice daily, for 2-3 days. The median total dosage of external radiation therapy was 48 Gy (14-66 Gy), 2 Gy/fraction. Results: Jaundice was released after metal stenting from 71.4% to 14.3% (P=0.001), showing no significant difference between brachytherapy and external radiation therapy in terms of jaundice release(χ 2 =0.21, P=0.65). The median survival period(5-35 months)for whole groups was 12 months 1-, 2-year survival rates were 40.8% and 8.16%, respectively. No significant difference was shown for patients received either brachytherapy or external radiation therapy for 8 months, but with 1,2 year survival rate as 40.0%, 13.3%, respectively (χ 2 =1.10, P=0.29). Conclusions: Self-expanding metal stenting is able to release jaundice significantly and followed by high dose radiation therapy may further prolong the survival. (authors)

  19. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  20. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  1. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  2. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. EUS-guided recanalization of complete gastrointestinal strictures

    Directory of Open Access Journals (Sweden)

    Miguel Martínez-Guillén

    Full Text Available Background and aim: Complete gastrointestinal strictures are a technically demanding problem. In this setting, an anterograde technique is associated with a high risk of complications and a combined anterograde-retrograde technique requires a prior ostomy. Our aim was to assess the outcome of a first case series for the management of complete gastrointestinal strictures using endoscopic ultrasound (EUS-guided puncture as a novel endoscopic approach. Patients and methods: This retrospective case-series describes four cases that were referred for treatment of complete benign gastrointestinal strictures, three upper and one lower. Recanalization was attempted with EUS-guided puncture using a 22G or 19G needle and contrast filling was visualized by fluoroscopy. Afterwards, a cystotome and/or a dilator balloon were used under endoscopic and fluoroscopic guidance. A fully covered metal stent was placed in two cases, keeping the strictures open in order to prevent another stricture. Feasibility, adverse events, efficacy and the number of dilations required after recanalization were evaluated. Results: Technical and clinical success was achieved in three of the four cases (75%. A first dilation was performed using a dilator balloon in all successful cases and fully covered metal stents were used in two cases. These patients underwent a consecutive number of balloon dilatations (range 1-4 and all three were able to eat a soft diet. No adverse events were related to the EUS-guided approach. In the failed case with a long stricture (> 3 cm, an endoscopic rendezvous technique was attempted which caused a pneumothorax requiring a chest tube placement. Conclusion: EUS-guided recanalization, as a first approach in the treatment of complete digestive stricture, is a feasible and promising procedure that can help to avoid major surgery.

  4. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    Science.gov (United States)

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  5. Anderson localization and ballooning eigenfunctions

    International Nuclear Information System (INIS)

    Dewar, R.L.; Cuthbert, P.

    1999-01-01

    In solving the ballooning eigenvalue for a low-aspect-ratio stellarator equilibrium it is found that the quasiperiodic behaviour of the equilibrium quantities along a typical magnetic field line can lead to localization of the ballooning eigenfunction (Anderson localization) even in the limit of zero shear. This localization leads to strong field-line dependence of the ballooning eigenvalue, with different branches attaining their maximum growth rates on different field lines. A method is presented of estimating the field-line dependence of various eigenvalue branches by using toroidal and poloidal symmetry operations on the shear-free ballooning equation to generate an approximate set of eigenfunctions. These zero-shear predictions are compared with accurate numerical solutions for the H-1 Heliac and are shown to give a qualitatively correct picture, but finite shear corrections will be needed to give quantitative predictions

  6. WD-repeat instability and diversification of the Podospora anserina hnwd non-self recognition gene family.

    Science.gov (United States)

    Chevanne, Damien; Saupe, Sven J; Clavé, Corinne; Paoletti, Mathieu

    2010-05-06

    Genes involved in non-self recognition and host defence are typically capable of rapid diversification and exploit specialized genetic mechanism to that end. Fungi display a non-self recognition phenomenon termed heterokaryon incompatibility that operates when cells of unlike genotype fuse and leads to the cell death of the fusion cell. In the fungus Podospora anserina, three genes controlling this allorecognition process het-d, het-e and het-r are paralogs belonging to the same hnwd gene family. HNWD proteins are STAND proteins (signal transduction NTPase with multiple domains) that display a WD-repeat domain controlling recognition specificity. Based on genomic sequence analysis of different P. anserina isolates, it was established that repeat regions of all members of the gene family are extremely polymorphic and undergoing concerted evolution arguing for frequent recombination within and between family members. Herein, we directly analyzed the genetic instability and diversification of this allorecognition gene family. We have constituted a collection of 143 spontaneous mutants of the het-R (HNWD2) and het-E (hnwd5) genes with altered recognition specificities. The vast majority of the mutants present rearrangements in the repeat arrays with deletions, duplications and other modifications as well as creation of novel repeat unit variants. We investigate the extreme genetic instability of these genes and provide a direct illustration of the diversification strategy of this eukaryotic allorecognition gene family.

  7. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  8. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    Science.gov (United States)

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  9. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; Rauws, Erik A. J.; Fockens, Paul; van Hooft, Jeanin E.

    2015-01-01

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that

  10. Recent activities on the scientific ballooning in Japan

    International Nuclear Information System (INIS)

    Nisimura, J.; Hirosawa, H.

    1984-01-01

    Scientific ballooning is Japan has been organized by the Institute of Space and Astronautical Science, and about 15 balloons have been launched each year from Sanriku Balloon Center that belongs to this Institute. The balloon center is located in the northern part of Japan. The observations cover the field of X-ray, gamma-ray, infrared astronomy, cosmic rays, and atmospheric science. Systems of lon duration flights such as 'Boomerang Balloons', and fine attitude control systems were developed and widely applied to the scientific observations. International collaborative works were performed in Australia and Indonesia last year. Some details of these activities are reported and possible future collaborations with Braziian balloon group are also discussed. (Author) [pt

  11. Development of a Self-Management Theory-Guided Discharge Intervention for Parents of Hospitalized Children.

    Science.gov (United States)

    Sawin, Kathleen J; Weiss, Marianne E; Johnson, Norah; Gralton, Karen; Malin, Shelly; Klingbeil, Carol; Lerret, Stacee M; Thompson, Jamie J; Zimmanck, Kim; Kaul, Molly; Schiffman, Rachel F

    2017-03-01

    Parents of hospitalized children, especially parents of children with complex and chronic health conditions, report not being adequately prepared for self-management of their child's care at home after discharge. No theory-based discharge intervention exists to guide pediatric nurses' preparation of parents for discharge. To develop a theory-based conversation guide to optimize nurses' preparation of parents for discharge and self-management of their child at home following hospitalization. Two frameworks and one method influenced the development of the intervention: the Individual and Family Self-Management Theory, Tanner's Model of Clinical Judgment, and the Teach-Back method. A team of nurse scientists, nursing leaders, nurse administrators, and clinical nurses developed and field tested the electronic version of a nine-domain conversation guide for use in acute care pediatric hospitals. The theory-based intervention operationalized self-management concepts, added components of nursing clinical judgment, and integrated the Teach-Back method. Development of a theory-based intervention, the translation of theoretical knowledge to clinical innovation, is an important step toward testing the effectiveness of the theory in guiding clinical practice. Clinical nurses will establish the practice relevance through future use and refinement of the intervention. © 2017 Sigma Theta Tau International.

  12. The French balloon and sounding rocket space program

    Science.gov (United States)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  13. TMBM: Tethered Micro-Balloons on Mars

    Science.gov (United States)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  14. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.

    Science.gov (United States)

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa

    2017-09-14

    To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.

  15. Self-focusing and guiding of short laser pulses in ionizing gases and plasmas

    International Nuclear Information System (INIS)

    Esarey, E.; Sprangle, P.; Krall, J.; Ting, A.

    1997-01-01

    The propagation of intense laser pulses in gases and plasmas is relevant to a wide range of applications, including laser-driven accelerators, laser-plasma channeling, harmonic generation, supercontinuum generation, X-ray lasers, and laser-fusion schemes. Here, several features of intense, short-pulse (≤1 ps) laser propagation in gases undergoing ionization and in plasmas are reviewed, discussed, and analyzed. The wave equations for laser pulse propagation in a gas undergoing ionization and in a plasma are derived. The source-dependent expansion method is discussed, which is a general method for solving the paraxial wave equation with nonlinear source terms. In gases, the propagation of high-power (near the critical power) laser pulses is considered including the effects of diffraction, nonlinear self-focusing, ionization, and plasma generation. Self-guided solutions and the stability of these solutions are discussed. In plasmas, optical guiding by relativistic effects, ponderomotive effects, and preformed density channels is considered. The self-consistent plasma response is discussed, including plasma wave effects and instabilities such as self-modulation. Recent experiments on the guiding of laser pulses in gases and in plasmas are briefly summarized

  16. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F. [Dept. of Radiology, South Manchester University Hospitals NHS Trust, Withington Hospital (United Kingdom)

    1999-07-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  17. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    International Nuclear Information System (INIS)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F.

    1999-01-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  18. Comparison of Six- and Eight-Session Cognitive Guided Self-Help for Bulimia Nervosa

    Science.gov (United States)

    Furber, Gareth; Steele, Anna; Wade, Tracey D.

    2004-01-01

    A previous case-series evaluation of a six-session guided self-help (GSH) approach with 15 people with bulimia nervosa (BN) showed significant reductions across all measures, including binge eating, self-induced vomiting, weight concern, shape concern and dietary restraint. However, the reduction of binge eating and self-induced vomiting was…

  19. Evaluation of anti-migration properties of biliary covered self-expandable metal stents.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Imai, Hajime; Harwani, Yogesh; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Kadosaka, Kumpei; Sakurai, Toshiharu; Nishida, Naoshi; Kudo, Masatoshi

    2016-08-14

    To assess anti-migration potential of six biliary covered self-expandable metal stents (C-SEMSs) by using a newly designed phantom model. In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration (RFM) was measured by a force gauge on the stent end. Radial force (RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare (ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model. Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables (ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state. RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.

  20. Overview of the NASA balloon R&D program

    Science.gov (United States)

    Smith, I. Steve, Jr.

    1994-01-01

    The catastrophic balloon failure during the first half of the 1980's identified the need for a comprehensive and continuing balloon research and development (R&D) commitment by NASA. Technical understanding was lacking in many of the disciplines and processes associated with scientific ballooning. A comprehensive balloon R&D plan was developed in 1986 and implemented in 1987. The objectives were to develop the understanding of balloon system performance, limitations, and failure mechanisms. The program consisted of five major technical areas: structures, performance and analysis, materials, chemistry and processing, and quality control. Research activitites have been conducted at NASA/Goddard Space Flight Center (GSFC)-Wallops Flight Facility (WFF), other NASA centers and government facilities, universities, and the balloon manufacturers. Several new and increased capabilities and resources have resulted from this activity. The findings, capabilities, and plan of the balloon R&D program are presented.

  1. Balloon pulmonary valvotomy – Not just a simple balloon dilatation

    Directory of Open Access Journals (Sweden)

    Subhendu Mohanty

    2014-07-01

    Full Text Available Balloon pulmonary valvotomy is the preferred mode of treatment in patients with isolated pulmonary valvar stenosis and has shown good long term results. It is generally considered a safe procedure with few complications. There have been however, case reports of potentially fatal acute severe pulmonary edema occurring after the procedure in some patients. The cause of this complication and its pathophysiology is still not clear. Its occurrence is also infrequent with less than 5 cases reported till now. We report a case of pulmonary valvar stenosis which developed acute severe refractory pulmonary edema immediately after balloon pulmonary valvotomy.

  2. CAG repeat expansion in Huntington disease determines age at onset in a fully dominant fashion

    Science.gov (United States)

    Lee, J.-M.; Ramos, E.M.; Lee, J.-H.; Gillis, T.; Mysore, J.S.; Hayden, M.R.; Warby, S.C.; Morrison, P.; Nance, M.; Ross, C.A.; Margolis, R.L.; Squitieri, F.; Orobello, S.; Di Donato, S.; Gomez-Tortosa, E.; Ayuso, C.; Suchowersky, O.; Trent, R.J.A.; McCusker, E.; Novelletto, A.; Frontali, M.; Jones, R.; Ashizawa, T.; Frank, S.; Saint-Hilaire, M.H.; Hersch, S.M.; Rosas, H.D.; Lucente, D.; Harrison, M.B.; Zanko, A.; Abramson, R.K.; Marder, K.; Sequeiros, J.; Paulsen, J.S.; Landwehrmeyer, G.B.; Myers, R.H.; MacDonald, M.E.; Durr, Alexandra; Rosenblatt, Adam; Frati, Luigi; Perlman, Susan; Conneally, Patrick M.; Klimek, Mary Lou; Diggin, Melissa; Hadzi, Tiffany; Duckett, Ayana; Ahmed, Anwar; Allen, Paul; Ames, David; Anderson, Christine; Anderson, Karla; Anderson, Karen; Andrews, Thomasin; Ashburner, John; Axelson, Eric; Aylward, Elizabeth; Barker, Roger A.; Barth, Katrin; Barton, Stacey; Baynes, Kathleen; Bea, Alexandra; Beall, Erik; Beg, Mirza Faisal; Beglinger, Leigh J.; Biglan, Kevin; Bjork, Kristine; Blanchard, Steve; Bockholt, Jeremy; Bommu, Sudharshan Reddy; Brossman, Bradley; Burrows, Maggie; Calhoun, Vince; Carlozzi, Noelle; Chesire, Amy; Chiu, Edmond; Chua, Phyllis; Connell, R.J.; Connor, Carmela; Corey-Bloom, Jody; Craufurd, David; Cross, Stephen; Cysique, Lucette; Santos, Rachelle Dar; Davis, Jennifer; Decolongon, Joji; DiPietro, Anna; Doucette, Nicholas; Downing, Nancy; Dudler, Ann; Dunn, Steve; Ecker, Daniel; Epping, Eric A.; Erickson, Diane; Erwin, Cheryl; Evans, Ken; Factor, Stewart A.; Farias, Sarah; Fatas, Marta; Fiedorowicz, Jess; Fullam, Ruth; Furtado, Sarah; Garde, Monica Bascunana; Gehl, Carissa; Geschwind, Michael D.; Goh, Anita; Gooblar, Jon; Goodman, Anna; Griffith, Jane; Groves, Mark; Guttman, Mark; Hamilton, Joanne; Harrington, Deborah; Harris, Greg; Heaton, Robert K.; Helmer, Karl; Henneberry, Machelle; Hershey, Tamara; Herwig, Kelly; Howard, Elizabeth; Hunter, Christine; Jankovic, Joseph; Johnson, Hans; Johnson, Arik; Jones, Kathy; Juhl, Andrew; Kim, Eun Young; Kimble, Mycah; King, Pamela; Klimek, Mary Lou; Klöppel, Stefan; Koenig, Katherine; Komiti, Angela; Kumar, Rajeev; Langbehn, Douglas; Leavitt, Blair; Leserman, Anne; Lim, Kelvin; Lipe, Hillary; Lowe, Mark; Magnotta, Vincent A.; Mallonee, William M.; Mans, Nicole; Marietta, Jacquie; Marshall, Frederick; Martin, Wayne; Mason, Sarah; Matheson, Kirsty; Matson, Wayne; Mazzoni, Pietro; McDowell, William; Miedzybrodzka, Zosia; Miller, Michael; Mills, James; Miracle, Dawn; Montross, Kelsey; Moore, David; Mori, Sasumu; Moser, David J.; Moskowitz, Carol; Newman, Emily; Nopoulos, Peg; Novak, Marianne; O'Rourke, Justin; Oakes, David; Ondo, William; Orth, Michael; Panegyres, Peter; Pease, Karen; Perlman, Susan; Perlmutter, Joel; Peterson, Asa; Phillips, Michael; Pierson, Ron; Potkin, Steve; Preston, Joy; Quaid, Kimberly; Radtke, Dawn; Rae, Daniela; Rao, Stephen; Raymond, Lynn; Reading, Sarah; Ready, Rebecca; Reece, Christine; Reilmann, Ralf; Reynolds, Norm; Richardson, Kylie; Rickards, Hugh; Ro, Eunyoe; Robinson, Robert; Rodnitzky, Robert; Rogers, Ben; Rosenblatt, Adam; Rosser, Elisabeth; Rosser, Anne; Price, Kathy; Price, Kathy; Ryan, Pat; Salmon, David; Samii, Ali; Schumacher, Jamy; Schumacher, Jessica; Sendon, Jose Luis Lópenz; Shear, Paula; Sheinberg, Alanna; Shpritz, Barnett; Siedlecki, Karen; Simpson, Sheila A.; Singer, Adam; Smith, Jim; Smith, Megan; Smith, Glenn; Snyder, Pete; Song, Allen; Sran, Satwinder; Stephan, Klaas; Stober, Janice; Sü?muth, Sigurd; Suter, Greg; Tabrizi, Sarah; Tempkin, Terry; Testa, Claudia; Thompson, Sean; Thomsen, Teri; Thumma, Kelli; Toga, Arthur; Trautmann, Sonja; Tremont, Geoff; Turner, Jessica; Uc, Ergun; Vaccarino, Anthony; van Duijn, Eric; Van Walsem, Marleen; Vik, Stacie; Vonsattel, Jean Paul; Vuletich, Elizabeth; Warner, Tom; Wasserman, Paula; Wassink, Thomas; Waterman, Elijah; Weaver, Kurt; Weir, David; Welsh, Claire; Werling-Witkoske, Chris; Wesson, Melissa; Westervelt, Holly; Weydt, Patrick; Wheelock, Vicki; Williams, Kent; Williams, Janet; Wodarski, Mary; Wojcieszek, Joanne; Wood, Jessica; Wood-Siverio, Cathy; Wu, Shuhua; Yastrubetskaya, Olga; de Yebenes, Justo Garcia; Zhao, Yong Qiang; Zimbelman, Janice; Zschiegner, Roland; Aaserud, Olaf; Abbruzzese, Giovanni; Andrews, Thomasin; Andrich, Jurgin; Antczak, Jakub; Arran, Natalie; Artiga, Maria J. Saiz; Bachoud-Lévi, Anne-Catherine; Banaszkiewicz, Krysztof; di Poggio, Monica Bandettini; Bandmann, Oliver; Barbera, Miguel A.; Barker, Roger A.; Barrero, Francisco; Barth, Katrin; Bas, Jordi; Beister, Antoine; Bentivoglio, Anna Rita; Bertini, Elisabetta; Biunno, Ida; Bjørgo, Kathrine; Bjørnevoll, Inga; Bohlen, Stefan; Bonelli, Raphael M.; Bos, Reineke; Bourne, Colin; Bradbury, Alyson; Brockie, Peter; Brown, Felicity; Bruno, Stefania; Bryl, Anna; Buck, Andrea; Burg, Sabrina; Burgunder, Jean-Marc; Burns, Peter; Burrows, Liz; Busquets, Nuria; Busse, Monica; Calopa, Matilde; Carruesco, Gemma T.; Casado, Ana Gonzalez; Catena, Judit López; Chu, Carol; Ciesielska, Anna; Clapton, Jackie; Clayton, Carole; Clenaghan, Catherine; Coelho, Miguel; Connemann, Julia; Craufurd, David; Crooks, Jenny; Cubillo, Patricia Trigo; Cubo, Esther; Curtis, Adrienne; De Michele, Giuseppe; De Nicola, A.; de Souza, Jenny; de Weert, A. Marit; de Yébenes, Justo Garcia; Dekker, M.; Descals, A. Martínez; Di Maio, Luigi; Di Pietro, Anna; Dipple, Heather; Dose, Matthias; Dumas, Eve M.; Dunnett, Stephen; Ecker, Daniel; Elifani, F.; Ellison-Rose, Lynda; Elorza, Marina D.; Eschenbach, Carolin; Evans, Carole; Fairtlough, Helen; Fannemel, Madelein; Fasano, Alfonso; Fenollar, Maria; Ferrandes, Giovanna; Ferreira, Jaoquim J.; Fillingham, Kay; Finisterra, Ana Maria; Fisher, K.; Fletcher, Amy; Foster, Jillian; Foustanos, Isabella; Frech, Fernando A.; Fullam, Robert; Fullham, Ruth; Gago, Miguel; García, RocioGarcía-Ramos; García, Socorro S.; Garrett, Carolina; Gellera, Cinzia; Gill, Paul; Ginestroni, Andrea; Golding, Charlotte; Goodman, Anna; Gørvell, Per; Grant, Janet; Griguoli, A.; Gross, Diana; Guedes, Leonor; BascuñanaGuerra, Monica; Guerra, Maria Rosalia; Guerrero, Rosa; Guia, Dolores B.; Guidubaldi, Arianna; Hallam, Caroline; Hamer, Stephanie; Hammer, Kathrin; Handley, Olivia J.; Harding, Alison; Hasholt, Lis; Hedge, Reikha; Heiberg, Arvid; Heinicke, Walburgis; Held, Christine; Hernanz, Laura Casas; Herranhof, Briggitte; Herrera, Carmen Durán; Hidding, Ute; Hiivola, Heli; Hill, Susan; Hjermind, Lena. E.; Hobson, Emma; Hoffmann, Rainer; Holl, Anna Hödl; Howard, Liz; Hunt, Sarah; Huson, Susan; Ialongo, Tamara; Idiago, Jesus Miguel R.; Illmann, Torsten; Jachinska, Katarzyna; Jacopini, Gioia; Jakobsen, Oda; Jamieson, Stuart; Jamrozik, Zygmunt; Janik, Piotr; Johns, Nicola; Jones, Lesley; Jones, Una; Jurgens, Caroline K.; Kaelin, Alain; Kalbarczyk, Anna; Kershaw, Ann; Khalil, Hanan; Kieni, Janina; Klimberg, Aneta; Koivisto, Susana P.; Koppers, Kerstin; Kosinski, Christoph Michael; Krawczyk, Malgorzata; Kremer, Berry; Krysa, Wioletta; Kwiecinski, Hubert; Lahiri, Nayana; Lambeck, Johann; Lange, Herwig; Laver, Fiona; Leenders, K.L.; Levey, Jamie; Leythaeuser, Gabriele; Lezius, Franziska; Llesoy, Joan Roig; Löhle, Matthias; López, Cristobal Diez-Aja; Lorenza, Fortuna; Loria, Giovanna; Magnet, Markus; Mandich, Paola; Marchese, Roberta; Marcinkowski, Jerzy; Mariotti, Caterina; Mariscal, Natividad; Markova, Ivana; Marquard, Ralf; Martikainen, Kirsti; Martínez, Isabel Haro; Martínez-Descals, Asuncion; Martino, T.; Mason, Sarah; McKenzie, Sue; Mechi, Claudia; Mendes, Tiago; Mestre, Tiago; Middleton, Julia; Milkereit, Eva; Miller, Joanne; Miller, Julie; Minster, Sara; Möller, Jens Carsten; Monza, Daniela; Morales, Blas; Moreau, Laura V.; Moreno, Jose L. López-Sendón; Münchau, Alexander; Murch, Ann; Nielsen, Jørgen E.; Niess, Anke; Nørremølle, Anne; Novak, Marianne; O'Donovan, Kristy; Orth, Michael; Otti, Daniela; Owen, Michael; Padieu, Helene; Paganini, Marco; Painold, Annamaria; Päivärinta, Markku; Partington-Jones, Lucy; Paterski, Laurent; Paterson, Nicole; Patino, Dawn; Patton, Michael; Peinemann, Alexander; Peppa, Nadia; Perea, Maria Fuensanta Noguera; Peterson, Maria; Piacentini, Silvia; Piano, Carla; Càrdenas, Regina Pons i; Prehn, Christian; Price, Kathleen; Probst, Daniela; Quarrell, Oliver; Quiroga, Purificacion Pin; Raab, Tina; Rakowicz, Maryla; Raman, Ashok; Raymond, Lucy; Reilmann, Ralf; Reinante, Gema; Reisinger, Karin; Retterstol, Lars; Ribaï, Pascale; Riballo, Antonio V.; Ribas, Guillermo G.; Richter, Sven; Rickards, Hugh; Rinaldi, Carlo; Rissling, Ida; Ritchie, Stuart; Rivera, Susana Vázquez; Robert, Misericordia Floriach; Roca, Elvira; Romano, Silvia; Romoli, Anna Maria; Roos, Raymond A.C.; Røren, Niini; Rose, Sarah; Rosser, Elisabeth; Rosser, Anne; Rossi, Fabiana; Rothery, Jean; Rudzinska, Monika; Ruíz, Pedro J. García; Ruíz, Belan Garzon; Russo, Cinzia Valeria; Ryglewicz, Danuta; Saft, Carston; Salvatore, Elena; Sánchez, Vicenta; Sando, Sigrid Botne; Šašinková, Pavla; Sass, Christian; Scheibl, Monika; Schiefer, Johannes; Schlangen, Christiane; Schmidt, Simone; Schöggl, Helmut; Schrenk, Caroline; Schüpbach, Michael; Schuierer, Michele; Sebastián, Ana Rojo; Selimbegovic-Turkovic, Amina; Sempolowicz, Justyna; Silva, Mark; Sitek, Emilia; Slawek, Jaroslaw; Snowden, Julie; Soleti, Francesco; Soliveri, Paola; Sollom, Andrea; Soltan, Witold; Sorbi, Sandro; Sorensen, Sven Asger; Spadaro, Maria; Städtler, Michael; Stamm, Christiane; Steiner, Tanja; Stokholm, Jette; Stokke, Bodil; Stopford, Cheryl; Storch, Alexander; Straßburger, Katrin; Stubbe, Lars; Sulek, Anna; Szczudlik, Andrzej; Tabrizi, Sarah; Taylor, Rachel; Terol, Santiago Duran-Sindreu; Thomas, Gareth; Thompson, Jennifer; Thomson, Aileen; Tidswell, Katherine; Torres, Maria M. Antequera; Toscano, Jean; Townhill, Jenny; Trautmann, Sonja; Tucci, Tecla; Tuuha, Katri; Uhrova, Tereza; Valadas, Anabela; van Hout, Monique S.E.; van Oostrom, J.C.H.; van Vugt, Jeroen P.P.; vanm, Walsem Marleen R.; Vandenberghe, Wim; Verellen-Dumoulin, Christine; Vergara, Mar Ruiz; Verstappen, C.C.P.; Verstraelen, Nichola; Viladrich, Celia Mareca; Villanueva, Clara; Wahlström, Jan; Warner, Thomas; Wehus, Raghild; Weindl, Adolf; Werner, Cornelius J.; Westmoreland, Leann; Weydt, Patrick; Wiedemann, Alexandra; Wild, Edward; Wild, Sue; Witjes-Ané, Marie-Noelle; Witkowski, Grzegorz; Wójcik, Magdalena; Wolz, Martin; Wolz, Annett; Wright, Jan; Yardumian, Pam; Yates, Shona; Yudina, Elizaveta; Zaremba, Jacek; Zaugg, Sabine W.; Zdzienicka, Elzbieta; Zielonka, Daniel; Zielonka, Euginiusz; Zinzi, Paola; Zittel, Simone; Zucker, Birgrit; Adams, John; Agarwal, Pinky; Antonijevic, Irina; Beck, Christopher; Chiu, Edmond; Churchyard, Andrew; Colcher, Amy; Corey-Bloom, Jody; Dorsey, Ray; Drazinic, Carolyn; Dubinsky, Richard; Duff, Kevin; Factor, Stewart; Foroud, Tatiana; Furtado, Sarah; Giuliano, Joe; Greenamyre, Timothy; Higgins, Don; Jankovic, Joseph; Jennings, Dana; Kang, Un Jung; Kostyk, Sandra; Kumar, Rajeev; Leavitt, Blair; LeDoux, Mark; Mallonee, William; Marshall, Frederick; Mohlo, Eric; Morgan, John; Oakes, David; Panegyres, Peter; Panisset, Michel; Perlman, Susan; Perlmutter, Joel; Quaid, Kimberly; Raymond, Lynn; Revilla, Fredy; Robertson, Suzanne; Robottom, Bradley; Sanchez-Ramos, Juan; Scott, Burton; Shannon, Kathleen; Shoulson, Ira; Singer, Carlos; Tabbal, Samer; Testa, Claudia; van, Kammen Dan; Vetter, Louise; Walker, Francis; Warner, John; Weiner, illiam; Wheelock, Vicki; Yastrubetskaya, Olga; Barton, Stacey; Broyles, Janice; Clouse, Ronda; Coleman, Allison; Davis, Robert; Decolongon, Joji; DeLaRosa, Jeanene; Deuel, Lisa; Dietrich, Susan; Dubinsky, Hilary; Eaton, Ken; Erickson, Diane; Fitzpatrick, Mary Jane; Frucht, Steven; Gartner, Maureen; Goldstein, Jody; Griffith, Jane; Hickey, Charlyne; Hunt, Victoria; Jaglin, Jeana; Klimek, Mary Lou; Lindsay, Pat; Louis, Elan; Loy, Clemet; Lucarelli, Nancy; Malarick, Keith; Martin, Amanda; McInnis, Robert; Moskowitz, Carol; Muratori, Lisa; Nucifora, Frederick; O'Neill, Christine; Palao, Alicia; Peavy, Guerry; Quesada, Monica; Schmidt, Amy; Segro, Vicki; Sperin, Elaine; Suter, Greg; Tanev, Kalo; Tempkin, Teresa; Thiede, Curtis; Wasserman, Paula; Welsh, Claire; Wesson, Melissa; Zauber, Elizabeth

    2012-01-01

    Objective: Age at onset of diagnostic motor manifestations in Huntington disease (HD) is strongly correlated with an expanded CAG trinucleotide repeat. The length of the normal CAG repeat allele has been reported also to influence age at onset, in interaction with the expanded allele. Due to profound implications for disease mechanism and modification, we tested whether the normal allele, interaction between the expanded and normal alleles, or presence of a second expanded allele affects age at onset of HD motor signs. Methods: We modeled natural log-transformed age at onset as a function of CAG repeat lengths of expanded and normal alleles and their interaction by linear regression. Results: An apparently significant effect of interaction on age at motor onset among 4,068 subjects was dependent on a single outlier data point. A rigorous statistical analysis with a well-behaved dataset that conformed to the fundamental assumptions of linear regression (e.g., constant variance and normally distributed error) revealed significance only for the expanded CAG repeat, with no effect of the normal CAG repeat. Ten subjects with 2 expanded alleles showed an age at motor onset consistent with the length of the larger expanded allele. Conclusions: Normal allele CAG length, interaction between expanded and normal alleles, and presence of a second expanded allele do not influence age at onset of motor manifestations, indicating that the rate of HD pathogenesis leading to motor diagnosis is determined by a completely dominant action of the longest expanded allele and as yet unidentified genetic or environmental factors. Neurology® 2012;78:690–695 PMID:22323755

  3. Self-compression of spatially limited laser pulses in a system of coupled light-guides

    Science.gov (United States)

    Balakin, A. A.; Litvak, A. G.; Mironov, V. A.; Skobelev, S. A.

    2018-04-01

    The self-action features of wave packets propagating in a 2D system of equidistantly arranged fibers are studied analytically and numerically on the basis of the discrete nonlinear Schrödinger equation. Self-consistent equations for the characteristic scales of a Gaussian wave packet are derived on the basis of the variational approach, which are proved numerically for powers P beams become filamented, and their amplitude is limited due to the nonlinear breaking of the interaction between neighboring light-guides. This makes it impossible to collect a powerful wave beam in a single light-guide. Variational analysis shows the possibility of the adiabatic self-compression of soliton-like laser pulses in the process of 3D self-focusing on the central light-guide. However, further increase of the field amplitude during self-compression leads to the development of longitudinal modulation instability and the formation of a set of light bullets in the central fiber. In the regime of hollow wave beams, filamentation instability becomes predominant. As a result, it becomes possible to form a set of light bullets in optical fibers located on the ring.

  4. Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

    Directory of Open Access Journals (Sweden)

    Seong Lee

    2015-10-01

    Full Text Available Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, 47.7±9.7 years; 11 female and 4 male who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was 13.5±7 years. The mean preoperative Wilkins score was 9.4±2.6. Results: The mean mitral valve area obtained using planimetry increased from 1.16±0.16 cm2 to 1.62±0.34 cm2 (p=0.0001. The mean pressure half time obtained using Doppler ultrasound decreased from 202.4±58.6 ms to 152±50.2 ms (p=0.0001. The mean pressure gradient obtained using Doppler ultrasound decreased from 9.4±4.0 mmHg to 5.8±1.5 mmHg (p=0.0021. There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period (39±16 months. The 5-year event-free survival was 56.16% (95% confidence interval, 47.467–64.866. Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

  5. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  6. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    Gorham, Peter W.

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  7. Detecting Seismic Infrasound Signals on Balloon Platforms

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M.; Garcia, R.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-12-01

    The determination of the interior structure of a planet requires detailed seismic investigations - a process that entails the detection and characterization of seismic waves due to geological activities (e.g., earthquakes, volcanoes, etc.). For decades, this task has primarily been performed on Earth by an ever-expanding network of terrestrial seismic stations. However, on planets such as Venus, where the surface pressure and temperature can reach as high as 90 atmospheres and 450 degrees Celsius respectively, placing seismometers on the planet's surface poses a vexing technological challenge. However, the upper layers of the Venusian atmosphere are more benign and capable of hosting geophysical payloads for longer mission lifetimes. In order to achieve the aim of performing geophysical experiments from an atmospheric platform, JPL and its partners (ISAE-SUPAERO and California Institute of Technology) are in the process of developing technologies for detection of infrasonic waves generated by earthquakes from a balloon. The coupling of seismic energy into the atmosphere critically depends on the density differential between the surface of the planet and the atmosphere. Therefore, the successful demonstration of this technique on Earth would provide ample reason to expect success on Venus, where the atmospheric impedance is approximately 60 times that of Earth. In this presentation, we will share results from the first set of Earth-based balloon experiments performed in Pahrump, Nevada in June 2017. These tests involved the generation of artificial sources of known intensity using a seismic hammer and their detection using a complex network of sensors, including highly sensitive micro-barometers suspended from balloons, GPS receivers, geophones, microphones, and seismometers. This experiment was the first of its kind and was successful in detecting infrasonic waves from the earthquakes generated by the seismic hammer. We will present the first comprehensive analysis

  8. Is self-guided internet-based cognitive behavioural therapy (iCBT) harmful? An individual participant data meta-analysis.

    Science.gov (United States)

    Karyotaki, Eirini; Kemmeren, Lise; Riper, Heleen; Twisk, Jos; Hoogendoorn, Adriaan; Kleiboer, Annet; Mira, Adriana; Mackinnon, Andrew; Meyer, Björn; Botella, Cristina; Littlewood, Elizabeth; Andersson, Gerhard; Christensen, Helen; Klein, Jan P; Schröder, Johanna; Bretón-López, Juana; Scheider, Justine; Griffiths, Kathy; Farrer, Louise; Huibers, Marcus J H; Phillips, Rachel; Gilbody, Simon; Moritz, Steffen; Berger, Thomas; Pop, Victor; Spek, Viola; Cuijpers, Pim

    2018-03-15

    Little is known about potential harmful effects as a consequence of self-guided internet-based cognitive behaviour therapy (iCBT), such as symptom deterioration rates. Thus, safety concerns remain and hamper the implementation of self-guided iCBT into clinical practice. We aimed to conduct an individual participant data (IPD) meta-analysis to determine the prevalence of clinically significant deterioration (symptom worsening) in adults with depressive symptoms who received self-guided iCBT compared with control conditions. Several socio-demographic, clinical and study-level variables were tested as potential moderators of deterioration. Randomised controlled trials that reported results of self-guided iCBT compared with control conditions in adults with symptoms of depression were selected. Mixed effects models with participants nested within studies were used to examine possible clinically significant deterioration rates. Thirteen out of 16 eligible trials were included in the present IPD meta-analysis. Of the 3805 participants analysed, 7.2% showed clinically significant deterioration (5.8% and 9.1% of participants in the intervention and control groups, respectively). Participants in self-guided iCBT were less likely to deteriorate (OR 0.62, p guided iCBT has a lower rate of negative outcomes on symptoms than control conditions and could be a first step treatment approach for adult depression as well as an alternative to watchful waiting in general practice.

  9. Improving Hearing Aid Self-Efficacy and Utility Through Revising a Hearing Aid User Guide: A Pilot Study.

    Science.gov (United States)

    McMullan, Alexandra; Kelly-Campbell, Rebecca J; Wise, Kim

    2018-03-08

    This pilot study aimed to investigate whether revising a hearing aid user guide (HAUG) is associated with improved hearing aid self-efficacy and utility performance. In Part 1, an HAUG was evaluated using the Suitability Assessment of Material (SAM) and readability formulas (Flesch Reading Ease [Flesch, 1943], Flesch-Kincaid Readability Formula [Kincaid, Fishburne, Rogers, & Chissom, 1957], and Simple Measure of Gobbledygook [McLaughlin, 1969]). The HAUG was revised using results from the SAM and best practice guidelines. The revision included generating a video. In Part 2, 30 adults with hearing impairment were randomly assigned to use either the original guide (N = 15) or the revised guide and video (N = 15) to perform a utility task. Participants' self-efficacy was measured using the Basic and Advanced Handling subscales of the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids questionnaire. SAM and readability were compared between the original and revised guides (Doak, Doak, & Root, 1996). SAM and readability were improved following the revision. Participants in the revised guide group performed significantly better on the utility task and on the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids subscales than participants in the original guide group. These results are encouraging as they indicate that there is scope to influence self-efficacy and utility performance through the use of appropriate HAUGs.

  10. Laser welding of balloon catheters

    Science.gov (United States)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  11. NASA Langley Research Center tethered balloon systems

    Science.gov (United States)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  12. Heat Transfer Model for Hot Air Balloons

    Science.gov (United States)

    Llado-Gambin, Adriana

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.

  13. Novel biliary self-expanding metal stents: indications and applications.

    Science.gov (United States)

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  14. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  15. Gigantic balloon type artificial lightning generator

    Energy Technology Data Exchange (ETDEWEB)

    Horii; kenji

    1988-09-05

    This paper outlines a hot-air balloon type Van de Graaf 50-MV generator which can generate a 50,000,000 V, 0.2 to 0.3 coulomb artificial lightning comparable to natural lightning discharge and reports the results of investigation on discharging experiments conducted using this apparatus. The subjects covered are as follows: (1) Outline of the hot-air balloon type Van de Graaf 50-MV generator, (2) electric characteristics of the Van de Graaf 50-MV generator, (3) charge transfer with film and balloon charging, (4) the load of the balloon and buoyancy calculation, (5) leakage of charges, (6) study of charging experiments, and (7) evaluation of the apparatus and its method and problems to be solved. (4 figs, 4 tabs, 4 refs)

  16. Physical property and MR imaging of self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee; Kang, Sung Gwon; Cho, Young Kook; Kim, Hyung Jin; Lim, Myung Kwan; Cho, Soon Gu; Yoh, Kyu Tong; Suh, Chang Hae [Inha Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    In order to furnish basic information prior to their use, the physical properties of various self-expandable metallic stents and their MR characteristics were evaluated. Four commercially available self-expandable metallic stents-Gianturco-the Rosch, Hanaro, Memotherm, and Wallstent-were used in this study. For evaluation of the physical properties of each, hoop strengths and changes in radii according to the degrees of longitudinal flexion were compared. Stent characteristics seen on MR images were evaluated by measuring magnetic torque and by comparing images obtained in the vascular phantom using SE T1TI, FSE T2WI, and FMPSPGR sequences. These images were analyzed with special emphasis on artifact size and the apparant shepe of the stent. Hoop strength was greatest in the Gianturco-Rosch stent, followed by the Memotherm, Hanaro, and Wallstent. When flexed in the longitudinal axis, the radius of the Hanaro and Memotherm stent decreased slightly as a larger flexion angle was applied. When this was 90 deg, however, the connection of the Gianturco-Rosch stent collapsed. In contrast, the radius of the Wallstent became larger as a larger flexion angle was applied. At the portal of the MR imaging unit, neither the Memotherm nor Wallstent showed deflection; except for a thin hyperintense rim at both ends, their images were excellent, and the lumina of these stents were also clearly seen. In contrast, the Gianturco-Rosch and Hanaro stent demonstrated large deflexion and showed a severe black-hole artifact. As a result, visualization of the stents themselves and their lumina was impossible. The Gianturco-Rosch stent showed greatrer hoop strength than the others. The Wallstent showed good longitudinal flexibility and was thought to be effective in tortuous vessels. For follow-up after placement, especially when the nonferromagnetic Memotherm and Wallstent are used, MR imaging appears to be safe and useful.=20.

  17. Management of post-gastrectomy anastomosis site obstruction with a self-expandable metallic stent.

    Science.gov (United States)

    Cha, Ra Ri; Lee, Sang Soo; Kim, Hyunjin; Kim, Hong Jun; Kim, Tae-Hyo; Jung, Woon Tae; Lee, Ok Jae; Bae, Kyung Soo; Jeong, Sang-Ho; Ha, Chang Yoon

    2015-04-28

    Post-gastrectomy anastomosis site obstruction is a relatively rare complication after a subtotal gastrectomy. We present a case of a 75-year-old man who underwent a truncal vagotomy, omental patch, gastrojejunostomy, and Braun anastomosis for duodenal ulcer perforation and a gastric outlet obstruction. Following the 10(th) postoperative day, the patient complained of abdominal discomfort and vomiting. We diagnosed post-gastrectomy anastomosis site obstruction by an upper gastrointestinal series and an upper endoscopic examination. We inserted a self-expandable metallic stent (SEMS) at the anastomosis site. The stent was fully expanded after deployment. On the day following the stent insertion, the patient began to eat, and his abdominal discomfort was resolved. This paper describes the successful management of post-gastrectomy anastomosis site obstruction with temporary placement of a SEMS.

  18. Five-Year Outcomes of the First Pivotal Clinical Trial of Balloon-Expandable Transcatheter Aortic Valve Replacement in Japan (PREVAIL JAPAN).

    Science.gov (United States)

    Sawa, Yoshiki; Takayama, Morimasa; Goto, Tsuyoshi; Takanashi, Shuichiro; Komiya, Tatsuhiko; Tobaru, Tetsuya; Maeda, Koichi; Kuratani, Toru; Sakata, Yasushi

    2017-07-25

    Transcatheter aortic valve replacement (TAVR) has been an alternative less invasive therapy for high-surgical risk/inoperable patients with aortic valve stenosis (AS) in Japan. We report 5-year outcomes of the first pivotal clinical trial of TAVR in Japan (PREVAIL JAPAN).Methods and Results:A total of 64 patients with AS who were considered unsuitable candidates for surgery were enrolled at 3 centers in Japan (mean age: 84.3±6.1 years, female: 65.6%, STS score: 9.0±4.5%). Transfemoral approach (TF) and transapical approach (TA) was performed in 37 patients and 27 patients, respectively. At 5 years, freedom from all-cause death was 52.7% (TF: 51.3%, TA: 56.3%). Risk of all stroke at 5-year was 15.8% (TF: 8.9%, TA: 25.5%) and risk of major adverse cardiac and cerebrovascular events at 5 years was 58.0% (TF: 51.3%, TA: 69.2%). Mild or greater aortic regurgitation (AR) at 1 week was not associated with increased all-cause death at 5 years (69.1%) compared with none or trace AR (48.3%) (P=0.184). Patients with high STS score (>8) had higher mortality rate than those with low STS scores (≤8). The 5-year data from PREVAIL JAPAN show the clinical benefit of TAVR and suggest that balloon-expandable TAVR is an effective treatment option for Japanese patients with severe AS who are not suitable for surgery. (Funded by Edwards Lifesciences Limited; ClinicalTrials.gov number, NCT01113983.).

  19. Lightweight self-compacting concrete with light expanded clay aggregate (LECA

    Directory of Open Access Journals (Sweden)

    Heiza Khaled

    2018-01-01

    Full Text Available Lightweight concretes have been successfully applied in building constructions for many years due to their favorable material properties, particularly their low specific weight in connection with a high strength, a high capability of thermal insulation and a high durability. The development leading to lightweight self-compacting concrete (LWSCC represents an important advanced step within the recent years. This concrete combines the favorable properties of a lightweight concrete with those of a self-compacting concrete. Research work is aimed on development of (LWSCC with the use of light aggregates “Light expanded clay aggregate (LECA”. In this research, first by specific gravity factor method, twenty different mix designs of (LWSCC were cast and tested to find out the values of slump flow, J-ring , V-funnel and 28 day compressive strength. Based on the results obtained, the best mix design was selected for further investigation. This paper also focuses on studying the effect of changing the reinforcement ratio on reinforced two way slabs when the dimensions were kept constant.

  20. Balloon dilatation biopsy of the biliary stricture through the percutaneous transhepatic biliary drainage tract: Feasibility and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Ji Hoon; Ryeom, Hun Kyu; Jang, Yun Jin; Kim, Gab Chul; Cho, Seung Hyun; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2016-01-15

    To evaluate the feasibility and diagnostic accuracy of the balloon dilatation biopsy for the biliary stricture through the percutaneous transhepatic biliary drainage (PTBD) tract. The study included 35 patients who underwent balloon dilatation biopsy for the biliary stricture through the PTBD tract. Balloon dilatation was done with a balloon catheter of 10-mm or 12-mm diameter. Soft tissue adherent to the retrieved balloon catheter and soft tissue components separated by gauze filtration of evacuated bile were sampled for histopathologic examination. The results were compared with the final diagnosis which was made by clinical and imaging follow-up for mean 989 days (n = 34) and surgery with histopathologic examination (n = 1). Procedure-related complications and diagnostic accuracy were assessed. Tissues suitable for histopathologic examination were obtained in 31 out of 35 patients (88.6%). In 3 patients, self-limiting hemobilia was noted. No major complication was noted. The sensitivity, specificity, diagnostic accuracy, positive and negative predictive values for diagnosis of malignant stricture were 70.0%, 100%, 90.3%, 100%, and 87.5%, respectively. Balloon dilatation biopsy of the biliary stricture through the PTBD tract is a feasible and accurate diagnostic method. It can be a safe alternative to the endoscopic retrograde cholangiography biopsy or forceps biopsy through the PTBD tract.

  1. Balloon cell nevus of the iris.

    Science.gov (United States)

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  2. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  3. USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE

    Directory of Open Access Journals (Sweden)

    M. N. Kornilov

    2013-01-01

    Full Text Available Aim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct anastomotic strictures we’ve used only the self-expandable coated nitinol stent. We performed stenting in 7 recipient. Result. In 131 liver transplant recipients incidence of biliary strictures has been 5.3%. All of 5 patients have been managed by retrograde or antegrade way. Conclusion. Our first experience demonstrate efficacy and safety of the used tecniques up to 24 months. The analysis of more long-term results is required. 

  4. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign

  5. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-02-16

    To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and

  6. Top-nozzle mounted replacement guide pin assemblies

    International Nuclear Information System (INIS)

    Gilmore, C.B.; Andrews, W.H.

    1993-01-01

    A replacement guide pin assembly is provided for aligning a nuclear fuel assembly with an upper core plate of a nuclear reactor core. The guide pin assembly includes a guide pin body having a radially expandable base insertable within a hole in the top nozzle, a ferrule insertable within the guide pin base and capable of imparting a radially and outwardly directed force on the expandable base to expand it within the hole of the top nozzle and thereby secure the guide pin body to the top nozzle in response to a predetermined displacement of the ferrule relative to the guide pin body along its longitudinal axis, and a lock screw interfitted with the ferrule and threaded into the guide pin body so as to produce the predetermined displacement of the ferrule. (author)

  7. Vertical sounding balloons for stratospheric photochemistry

    Science.gov (United States)

    Pommereau, J. P.

    The use of vertical sounding balloons for stratospheric photochemistry studies is illustrated by the use of a vertical piloted gas balloon for the search of NO2 diurnal variations. It is shown that the use of montgolfieres (hot air balloons) can enhance the vertical sounding technique. Particular attention is given to a sun-heated montgolfiere and to the more sophisticated infrared montgolfiere that is able to perform three to four vertical excursions per day and to remain aloft for weeks or months.

  8. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction.

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-08-14

    To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization's scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure.

  9. Long-term results of percutaneous self-expandable metallic stents in malignant biliary obstruction

    International Nuclear Information System (INIS)

    Kobashi, Yuko; Hoshikawa, Yoshikazu

    2004-01-01

    Evaluation of the long-term follow-up data of 155 patients with inoperable malignant biliary obstruction who received percutaneous placement of self expandable metallic stent (EMS) and external beam radiotherapy (EBR) combined with self-expandable metallic stent. One-hundred sixty EMS were inserted in 155 patients with inoperable malignant biliary obstruction. One-hundred forty-three patients (Group A) were inserted EMS alone. Twelve patients (Group B) underwent external radiotherapy (40∼45 Gy) after stent insertion. We compared to the Group A and Group B about survival, stent patency and administration. The mean length of survival for the entire group was 111±87 days, while the mean period of patency for all stents was 103±74. We found no statistically significant difference in patient survival or stent patency periods in regard to the level and cause of obstruction. Prolongation of actuarial survival was observed in Group B (316±231 days) as compared to Group A (126±85 days,). Mean length of survival rate and mean period of stent patency rate were not significantly different in regard to the level, cause of obstruction and each stent. External radiotherapy combined EMS could achieve effective palliation and improve the quality of life in selected patients with malignant biliary obstruction. (author)

  10. The management of unimplantable stent during endovascular procedure:report of three cases

    International Nuclear Information System (INIS)

    Xiong Jiang; Wang Lijun; Guo Wei; Liu Xiaoping; Yin Tai; Jia Xin; Ma Xiaohui; Liu Meng; Zhang Hongpeng; Zhang Minhong

    2010-01-01

    Objective: To summarize the experience of dealing with the difficulty of the stent implantation encountered in the endovascular procedure. Methods: The causes of unimplantable stent encountered in the endovascular procedure included the delivery system entraping due to the stenosis and shrinking of peripheral self-expandable stent, the balloon expandable stent implantation and retrievement failure due to the rupture-balloon or stent edge opening, and the delivery system entraping due to aortic stent graft for aorta kinking. The balloon dilation for the stenosis and shrinking stent, the large caliber introducer sheath for removal of the rupture-balloon and edge opening, the expandable stent and balloon-assisted delivery system retrieve were used to solve the above three dilemma of unimplantable stent occurred in the endovascular procedure. Results: These three dilemma of stent unimplantable problem in the endovascular therapy were solved by endovascular method while little additional incision injury was added to the patients. Conclusion: For solving stent unimplantable problem the endovascular technique is the method of first choice, nevertherless, it is very important for the operator to be highly skilled in manipulating endovascular procedure. (authors)

  11. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  12. Planetary Balloon-Based Science Platform Evaluation and Program Implementation

    Science.gov (United States)

    Dankanich, John W.; Kremic, Tibor; Hibbitts, Karl; Young, Eliot F.; Landis, Rob

    2016-01-01

    This report describes a study evaluating the potential for a balloon-based optical telescope as a planetary science asset to achieve decadal class science. The study considered potential science achievable and science traceability relative to the most recent planetary science decadal survey, potential platform features, and demonstration flights in the evaluation process. Science Potential and Benefits: This study confirms the cost the-benefit value for planetary science purposes. Forty-four (44) important questions of the decadal survey are at least partially addressable through balloon based capabilities. Planetary science through balloon observations can provide significant science through observations in the 300 nm to 5 m range and at longer wavelengths as well. Additionally, balloon missions have demonstrated the ability to progress from concept to observation to publication much faster than a space mission increasing the speed of science return. Planetary science from a balloon-borne platform is a relatively low-cost approach to new science measurements. This is particularly relevant within a cost-constrained planetary science budget. Repeated flights further reduce the cost of the per unit science data. Such flights offer observing time at a very competitive cost. Another advantage for planetary scientists is that a dedicated asset could provide significant new viewing opportunities not possible from the ground and allow unprecedented access to observations that cannot be realized with the time allocation pressures faced by current observing assets. In addition, flight systems that have a relatively short life cycle and where hardware is generally recovered, are excellent opportunities to train early career scientists, engineers, and project managers. The fact that balloon-borne payloads, unlike space missions, are generally recovered offers an excellent tool to test and mature instruments and other space craft systems. Desired Gondola Features: Potential

  13. Expand Your Horizon: A programme that improves body image and reduces self-objectification by training women to focus on body functionality.

    Science.gov (United States)

    Alleva, Jessica M; Martijn, Carolien; Van Breukelen, Gerard J P; Jansen, Anita; Karos, Kai

    2015-09-01

    This study tested Expand Your Horizon, a programme designed to improve body image by training women to focus on the functionality of their body using structured writing assignments. Eighty-one women (Mage=22.77) with a negative body image were randomised to the Expand Your Horizon programme or to an active control programme. Appearance satisfaction, functionality satisfaction, body appreciation, and self-objectification were measured at pretest, posttest, and one-week follow-up. Following the intervention, participants in the Expand Your Horizon programme experienced greater appearance satisfaction, functionality satisfaction, and body appreciation, and lower levels of self-objectification, compared to participants in the control programme. Partial eta-squared effect sizes were of small to medium magnitude. This study is the first to show that focusing on body functionality can improve body image and reduce self-objectification in women with a negative body image. These findings provide support for addressing body functionality in programmes designed to improve body image. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  15. Development of a Super-Pressure Balloon with an Improved Design

    Science.gov (United States)

    Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya

    A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.

  16. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  17. Assessment of guide vane self-excitation stability at small openings in pump flow

    International Nuclear Information System (INIS)

    Nennemann, B; Sallaberger, M; Henggeler, U; Gentner, C; Parkinson, E

    2012-01-01

    A parameter study of self-excited pump turbine guide vane instability at small openings using a combined CFD-1DOF approach shows that clear tendencies are difficult to obtain. Two types of boundary conditions can be used in the simulations: prescribed mass flow and prescribed pressure. Simulations with both show results that - for one specific operating condition - are consistent with a self-excited guide vane incident at a prototype pump turbine. However, over a larger range of reduced velocities, the tendencies obtained with the two boundary condition types are not always consistent. Pressure boundary conditions may be the more realistic option. Results then show that with increasing reduced velocity, guide vanes will eventually reach static instability or divergence. This may not be problematic. In contrast, passing through a zone of dynamic instability during operation should and can be avoided.

  18. Polyurethane-Covered Self-expandable Nitinol Stent for Malignant Biliary Obstruction: Preliminary Results

    International Nuclear Information System (INIS)

    Han, Young-Min; Hwang, Seung-Bae; Lee, Soo-Teik; Lee, Jeong-Min; Chung, Gyung-Ho

    2002-01-01

    Purpose: To evaluate the immediate and long-term results in ten patients with malignant biliary obstruction using a polyurethane-covered, self-expandable nitinol stent.Methods: A nitinol stent, fully covered with high-elasticity polyurethane, with an unconstrained diameter of 10 mm and a total length of 60-80 mm, was placed transhepatically under fluoroscopic guidance in ten patients. The length of the biliary obstruction varied between 30-50 mm. The follow-up examination included a clinical assessment, serum bilirubin measurement, and ultrasound examinations at one-month intervals in all patients. Results: Initial stent deployment was successful in eight patients. Two patients experienced proximal migration,which was solved by insertion of two, uncovered Wallstents. One patient had the stent removed after two weeks because of severe nausea and vomiting. One patient had delayed migration of the covered stent after 40 weeks. The follow-up duration was 3-40 weeks (Mean: 16.9 weeks). Seven patients died(3-26 weeks) and three patients survived (24-40 weeks). The bilirubin measurements in all patients had significantly decreased one week after stent insertion. The levels of amylase and lipase had did not increase after stent insertion. Conclusions: Apolyurethane-covered, self-expandable nitinol stent can be used effectively and safely in the treatment of malignant biliary obstruction. The preliminary results are favorable, but there is a need for further large studies to determine both long-term survival and patency

  19. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup

    1995-01-01

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction

  20. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-02-15

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction.

  1. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  2. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    Science.gov (United States)

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Use of Self-Expanding Metallic Ureteral Stents in the Secondary Treatment of Ureteral Stenosis Following Kidney Transplantation.

    Science.gov (United States)

    Xu, Guibin; Li, Xun; He, Yongzhong; Zhao, Haibo; Yang, Weiqing; Xie, Qingling

    2015-10-01

    To evaluate the safety and efficacy of self-expanding metal stents in the treatment of ureteral stenosis following kidney transplantation. Seven patients who developed benign stenosis after kidney transplantation were treated by a self-expanding metallic stent implantation from June 2007 to March 2014. All patients had undergone at least one open surgical procedure and one endourologic procedure for treatment of the stenosis. The extent of stenosis varied from 1.2 to 3.7 cm. Ultrasonography, urography, diuretic renography, and urine culture were performed every 3 months after stent insertion. Ureteroscopic examination was performed when needed. Stent placement was technically effective in all cases. The mean operative time was 37 minutes (range, 26-59 minutes). Lower urinary-tract symptoms and the ipsilateral flank pain were common early-stage complications and were greatly relieved after an average of 3 months. The mean follow-up duration was 38 months (range, 13-86 months), and no stent migration or fragmentation was observed. Urothelial hyperplasia occurred in only one patient and was effectively managed with a Double-J stent. Five patients had normal stable renal function; the remaining two had impaired renal function, including one patient with a preoperative renal failure who required dialysis at the end of the follow-up period (36 months). As an alternative to open surgery, implantation of a self-expanding metal stent is a safe and effective treatment for ureteral stenosis in patients who have undergone kidney transplantation.

  4. Self-expandable metal stents for obstructing colonic and extracolonic cancer

    DEFF Research Database (Denmark)

    van Hooft, Jeanin E; van Halsema, Emo E; Vanbiervliet, Geoffroy

    2014-01-01

    as a bridge to elective surgery is not recommended as a standard treatment of symptomatic left-sided malignant colonic obstruction (strong recommendation, high quality evidence). 3 For patients with potentially curable but obstructing left-sided colonic cancer, stent placement may be considered......, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations The following recommendations should only be applied after a thorough diagnostic evaluation including a contrast-enhanced computed tomography (CT) scan. 1 Prophylactic colonic...... stent placement is not recommended. Colonic stenting should be reserved for patients with clinical symptoms and imaging evidence of malignant large-bowel obstruction, without signs of perforation (strong recommendation, low quality evidence). 2 Colonic self-expandable metal stent (SEMS) placement...

  5. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  6. Balloon launching station, Mildura, Victoria

    International Nuclear Information System (INIS)

    The Mildura Balloon Launching Station was established in 1960 by the Department of Supply (now the Department of Manufacturing Industry) on behalf of the United States Atomic Energy Commission (USAEC) to determine the content of radioactive material in the upper atmosphere over Australia. The Station location and layout, staffing, balloon launching equipment, launching, tracking and recovery are described. (R.L.)

  7. Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications.

    Science.gov (United States)

    Ponte, Ana; Pinho, Rolando; Proença, Luísa; Silva, Joana; Rodrigues, Jaime; Sousa, Mafalda; Silva, João Carlos; Carvalho, João

    2017-06-16

    To describe a modified technique of deployment of stents using the overtube developed for balloon-assisted enteroscopy in post-sleeve gastrectomy (SG) complications. Between January 2010 and December 2015, all patients submitted to an endoscopic stenting procedure to treat a post-SG stenosis or leakage were retrospectively collected. Procedures from patients in which the stent was deployed using the balloon-overtube-assisted modified over-the-wire (OTW) stenting technique were described. The technical success, corresponding to proper placement of the stent in the stomach resulting in exclusion of the SG leak or the stenosis, was evaluated. Complications related to stenting were also reported. Five procedures were included to treat 2 staple line leaks and 3 stenoses. Two types of stents were used, including a fully covered self-expandable metal stent designed for the SG anatomy (Hanarostent, ECBB-30-240-090; M.I. Tech, Co., Ltd, Seoul, South Korea) in 4 procedures and a biodegradable stent (BD stent 019-10A-25/20/25-080, SX-ELLA, Hradec Kralove, Czech Republic) in the remaining procedure. In all cases, an overtube was advanced with the endoscope through the SG to the duodenum. After placement of the guidewire and removal of the endoscope, the stent was easily advanced through the overtube. The overtube was pulled back and the stent was successfully deployed under fluoroscopic guidance. Technical success was achieved in all patients. The adoption of a modified technique of deployment of OTW stents using an overtube may represent an effective option in the approach of SG complications.

  8. Benefits of Guided Self-Management of Attention on Learning Accounting

    Science.gov (United States)

    Sithole, Seedwell T. M.; Chandler, Paul; Abeysekera, Indra; Paas, Fred

    2017-01-01

    This research investigated the effects of 3 instructional design formats on learning introductory accounting. In accordance with cognitive load theory, it was predicted that students who would learn with a guided self-managed instructional design format would outperform students who would learn with a conventional split-attention format or an…

  9. Germ-line CAG repeat instability causes extreme CAG repeat expansion with infantile-onset spinocerebellar ataxia type 2

    DEFF Research Database (Denmark)

    Vinther-Jensen, Tua; Ek, Jakob; Duno, Morten

    2013-01-01

    The spinocerebellar ataxias (SCA) are a genetically and clinically heterogeneous group of diseases, characterized by dominant inheritance, progressive cerebellar ataxia and diverse extracerebellar symptoms. A subgroup of the ataxias is caused by unstable CAG-repeat expansions in their respective ...... of paternal germ-line repeat sequence instability of the expanded SCA2 locus.European Journal of Human Genetics advance online publication, 10 October 2012; doi:10.1038/ejhg.2012.231....

  10. [Balloon cell nevi of the conjunctiva (author's transl)].

    Science.gov (United States)

    Schlageter, P E; Daicker, B

    1975-06-01

    The clinical and histological features of three cases of conjunctival balloon cell nevi are described. This peculiar form of nevus is very rare in the conjunctiva. The findings are compared with the descriptions in the literature of dermal balloon cell nevi. They demonstrate, that the conjunctival and dermal tumours are of idential histological structure. The proliferations of the conjunctival epithelium often found in conjunctival nevi do not modify the balloon cell nevi. These can not be diagnosed clinically. The problems of the pathogenesis of the balloon cell nevi are discussed.

  11. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  12. Crystal-Structure-Guided Design of Self-Assembling RNA Nanotriangles.

    Science.gov (United States)

    Boerneke, Mark A; Dibrov, Sergey M; Hermann, Thomas

    2016-03-14

    RNA nanotechnology uses RNA structural motifs to build nanosized architectures that assemble through selective base-pair interactions. Herein, we report the crystal-structure-guided design of highly stable RNA nanotriangles that self-assemble cooperatively from short oligonucleotides. The crystal structure of an 81 nucleotide nanotriangle determined at 2.6 Å resolution reveals the so-far smallest circularly closed nanoobject made entirely of double-stranded RNA. The assembly of the nanotriangle architecture involved RNA corner motifs that were derived from ligand-responsive RNA switches, which offer the opportunity to control self-assembly and dissociation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. R-loops: targets for nuclease cleavage and repeat instability.

    Science.gov (United States)

    Freudenreich, Catherine H

    2018-01-11

    R-loops form when transcribed RNA remains bound to its DNA template to form a stable RNA:DNA hybrid. Stable R-loops form when the RNA is purine-rich, and are further stabilized by DNA secondary structures on the non-template strand. Interestingly, many expandable and disease-causing repeat sequences form stable R-loops, and R-loops can contribute to repeat instability. Repeat expansions are responsible for multiple neurodegenerative diseases, including Huntington's disease, myotonic dystrophy, and several types of ataxias. Recently, it was found that R-loops at an expanded CAG/CTG repeat tract cause DNA breaks as well as repeat instability (Su and Freudenreich, Proc Natl Acad Sci USA 114, E8392-E8401, 2017). Two factors were identified as causing R-loop-dependent breaks at CAG/CTG tracts: deamination of cytosines and the MutLγ (Mlh1-Mlh3) endonuclease, defining two new mechanisms for how R-loops can generate DNA breaks (Su and Freudenreich, Proc Natl Acad Sci USA 114, E8392-E8401, 2017). Following R-loop-dependent nicking, base excision repair resulted in repeat instability. These results have implications for human repeat expansion diseases and provide a paradigm for how RNA:DNA hybrids can cause genome instability at structure-forming DNA sequences. This perspective summarizes mechanisms of R-loop-induced fragility at G-rich repeats and new links between DNA breaks and repeat instability.

  14. Internet-based guided self-help for posttraumatic stress disorder (PTSD): Randomized controlled trial.

    Science.gov (United States)

    Lewis, Catrin E; Farewell, Daniel; Groves, Vicky; Kitchiner, Neil J; Roberts, Neil P; Vick, Tracey; Bisson, Jonathan I

    2017-06-01

    There are numerous barriers that limit access to evidence-based treatment for posttraumatic stress disorder (PTSD). Internet-based guided self-help is a treatment option that may help widen access to effective intervention, but the approach has not been sufficiently explored for the treatment of PTSD. Forty two adults with DSM-5 PTSD of mild to moderate severity were randomly allocated to internet-based self-help with up to 3 h of therapist assistance, or to a delayed treatment control group. The internet-based program included eight modules that focused on psychoeducation, grounding, relaxation, behavioural activation, real-life and imaginal exposure, cognitive therapy, and relapse prevention. The primary outcome measure was reduction in clinician-rated traumatic stress symptoms using the clinician administered PTSD scale for DSM-V (CAPS-5). Secondary outcomes were self-reported PTSD symptoms, depression, anxiety, alcohol use, perceived social support, and functional impairment. Posttreatment, the internet-based guided self-help group had significantly lower clinician assessed PTSD symptoms than the delayed treatment control group (between-group effect size Cohen's d = 1.86). The difference was maintained at 1-month follow-up and dissipated once both groups had received treatment. Similar patterns of difference between the two groups were found for depression, anxiety, and functional impairment. The average contact with treating clinicians was 2½ h. Internet-based trauma-focused guided self-help for PTSD is a promising treatment option that requires far less therapist time than current first line face-to-face psychological therapy. © 2017 Wiley Periodicals, Inc.

  15. Rotational atherectomy ablation for an unexpandable stent under the guide of IVUS

    Science.gov (United States)

    Si, Daoyuan; Liu, Guohui; Tong, Yaliang; He, Yuquan

    2018-01-01

    Abstract Rationale: Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. Patient concerns: We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques Diagnoses: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. Interventions: Under the guide of intravascular ultrasound (IVUS), rotational atherectomy (RA) successfully ablated the stent layers and the protruding calcified plaque. Followed by balloon angioplasty, the ablated segment was scaffolded with another stent, well expanded and documented by IVUS. Outcomes: The patient was uneventful during the procedure and remained angina free at the point of one year of clinical follow-up. Lessons: This case indicated that RA via the trans-radial approach could be a useful remedy in the situation of under-expansion of implanted stents, and the debulking should be performed under IVUS-guidance. PMID:29443790

  16. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ogo, Takeshi, E-mail: ogo.takeshi.hp@mail.ncvc.go.jp [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Department of Advanced Mediccal Research for Pulmonary Hypertension, National Cerebral and Cardiovascular Centre, Osaka (Japan); Fukuda, Tetsuya [Department of Radiology, National Cerebral and Cardiovascular Centre, Osaka (Japan); Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Sanda, Yoshihiro [Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Morita, Yoshiaki [Department of Radiology, National Cerebral and Cardiovascular Centre, Osaka (Japan); Asano, Ryotaro; Konagai, Nao [Division of Pulmonary Circulation, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan); Yasuda, Satoshi [Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Centre, Osaka (Japan)

    2017-04-15

    Highlights: • Recent advancement in CT enables distal CTEpH lesions to be visualized. • We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. • BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . • These new advanced CT techniques may be useful in pre-BPA target lesion assessment. - Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1 year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. Conclusions: BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment.

  17. Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography

    International Nuclear Information System (INIS)

    Ogo, Takeshi; Fukuda, Tetsuya; Tsuji, Akihiro; Fukui, Shigefumi; Ueda, Jin; Sanda, Yoshihiro; Morita, Yoshiaki; Asano, Ryotaro; Konagai, Nao; Yasuda, Satoshi

    2017-01-01

    Highlights: • Recent advancement in CT enables distal CTEpH lesions to be visualized. • We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. • BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . • These new advanced CT techniques may be useful in pre-BPA target lesion assessment. - Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1 year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. Conclusions: BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment.

  18. Retained intraaortic balloon. Case report and review of the literature.

    Science.gov (United States)

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  19. Percutaneous balloon dilation of pulmonary stenosis

    International Nuclear Information System (INIS)

    Hua Yangde; Huang Ming; Li Jinkang; Qian Jinqing; Chen Xiuyu; Yang Siyuan

    2003-01-01

    Objective: Review our experience of balloon dilation of valvular pulmonary stenosis in 32 cases. Methods: Totally 32 cases of pulmonary stenosis admitted from 1995-2001 with age of 1.5-13 yrs mean 6.8. Diagnosis was made by clinical manifestations, EKG, ECHO and angiocardiography. Results: Before dilation, the mean systolic pressure of right ventricle was (93.5 ± 28.5) mmHg, after the procedure it reduced to (42 ± 9.0) mmHg. The pressure gradient between right ventricle and pulmonary artery before dilation was (76 ± 30) mmHg and become (24.5 ± 8.5) mmHg after dilation. The gradient pressure after dilation was less than 25 mmHg in 90.6% cases. A case of Noonan syndrome showed no response to balloon dilation and died during valvulectomy from accompanying left ventricular cardiomyopathy. Conclusions: Balloon dilation of valvular pulmonary stenosis is effective and safe. The selection of proper diameter of pulmonary valvular rings and sized of the balloon are the major factors

  20. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  1. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; van Hooft, Jeanin E.

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective

  2. A pilot test of a self-guided, home-based intervention to improve condom-related sexual experiences, attitudes, and behaviors among young women.

    Science.gov (United States)

    Yarber, William L; Milhausen, Robin R; Beavers, Karly A; Ryan, Rebecca; Sullivan, Margaret J; Vanterpool, Karen B; Sanders, Stephanie A; Graham, Cynthia A; Crosby, Richard A

    2018-03-01

    To conduct a pilot test of a brief, self-guided, home-based program designed to improve male condom use attitudes and behaviors among young women. Women aged 18-24 years from a large Midwestern University reporting having had penile-vaginal sex with two or more partners in the past 3 months. Sixty-seven enrolled; 91.0% completed the study. A repeated measures design was used, with assessments occurring at baseline, immediately  post intervention (T2), and 30 days subsequent (T3). Condom use errors and problems decreased, condom-related attitudes and self-efficacy improved, and experiences of condom-protected sex were rated more positively when comparing baseline with T2 and T3 scores. Further, the proportion of condom-protected episodes more than doubled between T1 and T3 for those in the lowest quartile for condom use at baseline. This low-resource, home-based program improved condom-related attitudes and promoted the correct and consistent use of condoms.

  3. Balloon dilatation of ureteric strictures.

    Directory of Open Access Journals (Sweden)

    Punekar S

    2000-01-01

    Full Text Available AIMS: Evaluation of dilatation as a minimally invasive technique for the treatment of ureteric strictures. MATERIAL AND METHODS: We evaluated this technique in 16 patients with ureteric and secondary pelviureteric junction strictures from June 1998. Of these, 7 were men and 9 were women. The age range was from 14 to 40 years. RESULTS: Balloon dilatation was successful in 69% of patients. Strictures secondary to previous surgery had nearly 100% success. Of the 8 cases diagnosed as genitourinary tuberculosis, success rate was 50%. CONCLUSIONS: Factors affecting success of balloon dilatation are: a age of the stricture b length of the stricture and c etiology of the stricture. In a select group of patients with fresh post-operative or post-inflammatory strictures, balloon dilatation may be an attractive alternative to surgery.

  4. Treatment of benign esophageal stricture by Eder-Puestow or balloon dilators: a comparison between randomized and prospective nonrandomized trials.

    Science.gov (United States)

    Yamamoto, H; Hughes, R W; Schroeder, K W; Viggiano, T R; DiMagno, E P

    1992-03-01

    To determine whether the natural history of strictures is affected by the type of dilator used to treat newly diagnosed peptic strictures, we designed a prospective randomized trial to compare the results after Eder-Puestow or Medi-Tech balloon dilation. We entered 31 patients into the trial. We also prospectively followed up all 92 nonrandomized patients who underwent their first dilation for a benign stricture during the same period as the prospective randomized trial. The nonrandomized patients also underwent dilation with either the Eder-Puestow or the balloon technique at the discretion of the gastroenterologist performing the endoscopy. We found no statistically significant differences in the immediate or long-term results of the two methods among the randomized, nonrandomized, and overall combined groups. All but 1 of the 123 patients had immediate relief of dysphagia. Within each group of patients, the probability of remaining free of dysphagia 1 year after the initial dilation was approximately 20%, and the probability of not requiring a second dilation was approximately 65% with either technique. Major (esophageal rupture) and minor (bleeding or chest pain) complications occurred in 1% and 5% of the patients and 0.4% and 3% of the total dilation procedures, respectively. The esophageal rupture and four of six minor complications occurred after repeated dilations. Five of the six minor complications occurred with use of the Eder-Puestow dilators. We conclude that Eder-Puestow and balloon dilations of benign esophageal strictures are associated with similar outcomes, but repeated dilations and the Eder-Puestow technique may be associated with an increased risk of complications.

  5. Poly (Ethylene Glycol)-Based Hydrogels as Self-Inflating Tissue Expanders with Tunable Mechanical and Swelling Properties.

    Science.gov (United States)

    Jamadi, Mahsa; Shokrollahi, Parvin; Houshmand, Behzad; Joupari, Mortaza Daliri; Mashhadiabbas, Fatemeh; Khademhosseini, Ali; Annabi, Nasim

    2017-08-01

    Tissue expansion is used by plastic/reconstructive surgeons to grow additional skin/tissue for replacing or repairing lost or damaged soft tissues. Recently, hydrogels have been widely used for tissue expansion applications. Herein, a self-inflating tissue expander blend composition from three different molecular weights (2, 6, and 10 kDa) of poly (ethylene glycol) diacrylate (PEGDA) hydrogel with tunable mechanical and swelling properties is presented. The in vitro results demonstrate that, of the eight studied compositions, P6 (PEGDA 6 kDa:10 kDa (50:50)) and P8 (PEGDA 6 kDa:10 kDa (35:65)) formulations provide a balance of mechanical property and swelling capability suitable for tissue expansion. Furthermore, these expanders can be compressed up to 60% of their original height and can be loaded and unloaded cyclically at least ten times with no permanent deformation. The in vivo results indicate that these two engineered blend compositions are capable to generate a swelling pressure sufficient to dilate the surrounding tissue while retaining their original shape. The histological analyses reveal the formation of fibrous capsule at the interface between the implant and the subcutaneous tissue with no signs of inflammation. Ultimately, controlling the PEGDA chain length shows potential for the development of self-inflating tissue expanders with tunable mechanical and swelling properties. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Self-regulation theory: applications to medical education: AMEE Guide No. 58.

    Science.gov (United States)

    Sandars, John; Cleary, Timothy J

    2011-01-01

    Self-regulation theory, as applied to medical education, describes the cyclical control of academic and clinical performance through several key processes that include goal-directed behaviour, use of specific strategies to attain goals, and the adaptation and modification to behaviours or strategies to optimise learning and performance. Extensive research across a variety of non-medical disciplines has highlighted differences in key self-regulation processes between high- and low-achieving learners and performers. Structured identification of key self-regulation processes can be used to develop specific remediation approaches that can improve performance in academic and complex psycho-motor skills. General teaching approaches that are guided by a self-regulation perspective can also enhance academic performance. Self-regulation theory offers an exciting potential for improving academic and clinical performance in medical education.

  7. [The role of self-guided training in the relationship between task conflict and innovation in virtual teams].

    Science.gov (United States)

    Martínez Moreno, Edurne; Orengo Castellá, Virginia; Zornoza Abad, Ana

    2012-02-01

    This study was conducted to evaluate the moderating role of self-guided training in the relationship between task conflict and team innovation in synchronic computer-mediated communication (SCMC) teams. For this purpose, a laboratory study was carried out in which 26 teams were assigned to the training condition and 24 to the control condition. Results confirmed that SCMC teams develop a negative relationship between task conflict and innovation, but also revealed that self-guided training may slow these counterproductive effects down. Our study provides new evidence of the linear relationship between task conflict and team innovation in SCMC teams, extending previous research findings obtained in face-to-face teams to virtual context and suggest that self-guided training can be useful for virtual team innovation.

  8. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    Science.gov (United States)

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  9. Endovascular revascularization for aortoiliac atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Aggarwal V

    2016-03-01

    Full Text Available Vikas Aggarwal,1 Stephen W Waldo,2,3 Ehrin J Armstrong2,3 1Prairie Heart Institute, St John's Hospital, Springfield, IL, 2Section of Cardiology, Denver Veterans Affairs Medical Center, 3Section of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Atherosclerotic iliac artery disease is increasingly being treated with endovascular techniques. A number of new stent technologies can be utilized with high long-term patency, including self-expanding stents, balloon-expandable stents, and covered stents, but comparative data on these stent types and in more complex lesions are lacking. This article provides a review of currently available iliac stent technologies, as well as complex procedural aspects of iliac artery interventions, including approaches to the treatment of iliac bifurcation disease, long segment occlusions, choice of stent type, and treatment of iliac artery in-stent restenosis. Keywords: peripheral artery disease, iliac artery, balloon expandable stent, self expanding stent, covered stent, claudication, endovascular

  10. DNA-binding proteins from marine bacteria expand the known sequence diversity of TALE-like repeats.

    Science.gov (United States)

    de Lange, Orlando; Wolf, Christina; Thiel, Philipp; Krüger, Jens; Kleusch, Christian; Kohlbacher, Oliver; Lahaye, Thomas

    2015-11-16

    Transcription Activator-Like Effectors (TALEs) of Xanthomonas bacteria are programmable DNA binding proteins with unprecedented target specificity. Comparative studies into TALE repeat structure and function are hindered by the limited sequence variation among TALE repeats. More sequence-diverse TALE-like proteins are known from Ralstonia solanacearum (RipTALs) and Burkholderia rhizoxinica (Bats), but RipTAL and Bat repeats are conserved with those of TALEs around the DNA-binding residue. We study two novel marine-organism TALE-like proteins (MOrTL1 and MOrTL2), the first to date of non-terrestrial origin. We have assessed their DNA-binding properties and modelled repeat structures. We found that repeats from these proteins mediate sequence specific DNA binding conforming to the TALE code, despite low sequence similarity to TALE repeats, and with novel residues around the BSR. However, MOrTL1 repeats show greater sequence discriminating power than MOrTL2 repeats. Sequence alignments show that there are only three residues conserved between repeats of all TALE-like proteins including the two new additions. This conserved motif could prove useful as an identifier for future TALE-likes. Additionally, comparing MOrTL repeats with those of other TALE-likes suggests a common evolutionary origin for the TALEs, RipTALs and Bats. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. Properties of ballooning modes in the Heliotron configurations

    International Nuclear Information System (INIS)

    Nakajima, N.; Hudson, S.R.; Hegna, C.C.

    2005-01-01

    The stability of ballooning modes is influenced by the local and global magnetic shear and local and global magnetic curvature so significantly that it is fairly difficult to get those general properties in the three dimensional configurations with strong flexibility due to the external coil system. In the case of the planar axis heliotron configurations allowing a large Shafranov shift, like LHD, properties of the high-mode-number ballooning modes have been intensively investigated. It has been analytically shown that the local magnetic shear comes to disappear in the stellarator-like global magnetic shear region, as the Shafranov shift becomes large. Based on this mechanism and the characteristics of the local and global magnetic curvature, it is numerically shown that the destabilized ballooning modes have strong three-dimensional properties (both poloidal and toroidal mode couplings) in the Mercier stable region, and that those are fairly similar to ballooning modes in the axisymmetric system in the Mercier unstable region. As is well known, however, no quantization condition is applicable to the ballooning modes in the three-dimensional system without symmetry, and so the results of the high-mode-number ballooning modes in the covering space had to be confirmed in the real space. Such a confirmation has been done in the Mercier stable region and also in the Mercier unstable region by using three dimensional linearized ideal MHD stability code cas3d. Confirming the relation between high-mode-number ballooning analyses by the global mode analyses, the method of the equilibrium profile variations has been developed in the tree dimensional system, giving dt/dψ - dP/dψ stability diagram corresponding to the s - α diagram in tokamaks. This method of profile variation are very powerful to investigate the second stability of high-mode-number ballooning modes and has been more developed. Recently it has been applied to the plasma in the inward-shifted LHD

  12. CAG repeat expansion in Huntington disease determines age at onset in a fully dominant fashion

    DEFF Research Database (Denmark)

    Lee, J-M; Ramos, E M; Lee, J-H

    2012-01-01

    Age at onset of diagnostic motor manifestations in Huntington disease (HD) is strongly correlated with an expanded CAG trinucleotide repeat. The length of the normal CAG repeat allele has been reported also to influence age at onset, in interaction with the expanded allele. Due to profound...

  13. Giving Students Control over Their Learning; from Self-guided Museum Visits and Field Trips to Using Scanning Technology to Link Content to Earth Samples

    Science.gov (United States)

    Kirkby, K. C.; Phipps, M.

    2011-12-01

    While it may seem counterintuitive, sometimes stepping back is one of the more effective pedagogical approaches instructors can make. On museum visits, an instructor's presence fundamentally alters students' experiences and can curtail student learning by limiting questions or discouraging students from exploring their own interests. Students often rely on the instructor and become passive observers, rather than engaged learners. As an alternative to instructor-led visits, self-guided student explorations of museum exhibits proved to be both popular and pedagogically effective. On pre-instruction and post-instruction surveys, these ungraded, self-guided explorations match or exceed the efficacy of traditional graded lab instruction and completely eclipse gains normally achieved by traditional lecture instruction. In addition, these explorations achieve the remarkable goal of integrating undergraduate earth science instruction into students' social lives. Based on the success of the self-guided museum explorations, this fall saw the debut of an attempt to expand this concept to field experiences. A self-guided student field exploration of Saint Anthony Falls focuses on the intersections of geological processes with human history. Students explore the waterfalls' evolution, its early interpretation by 18th and 19th century Dakota and Euro-America societies, and its subsequent social and economic impacts on Upper Midwest societies. Self-guided explorations allow students to explore field settings on their own or with friends and family in a more relaxed manner. At the same time, these explorations give students control over, and responsibility for, their own learning - a powerful pedagogical approach. Student control over their learning is also the goal of an initiative to use scanning technologies, such as linear bar codes, 2D barcodes and radio-frequency identification (RFID), to revolutionize sample identification and study. Scanning technology allows students to

  14. Conformable covered versus uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction: a randomized prospective study.

    Science.gov (United States)

    Lim, Sun Gyo; Kim, Jin Hong; Lee, Kee Myung; Shin, Sung Jae; Kim, Chan Gyoo; Kim, Kyung Ho; Kim, Ho Gak; Yang, Chang Heon

    2014-07-01

    A conformable self-expandable metallic stent was developed to overcome the limitation of previous self-expandable metallic stents. The aim of this study was to evaluate outcomes after placement of conformable covered and uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction. A single-blind, randomized, parallel-group, prospective study were conducted in 4 medical centres between March 2009 and July 2012. 134 patients with unresectable malignant gastroduodenal obstruction were assigned to a covered double-layered (n=66) or uncovered unfixed-cell braided (n=68) stent placement group. Primary analysis was performed to compare re-intervention rates between two groups. 120 patients were analysed (59 in the covered group and 61 in the uncovered group). Overall rates of re-intervention were not significantly different between the two groups: 13/59 (22.0%) in the covered group vs. 13/61 (21.3%) in the uncovered group, p=0.999. Stent migration was more frequent in the covered group than in the uncovered group (p=0.003). The tumour ingrowth rate was higher in the uncovered group than in the covered group (p=0.016). The rates of re-intervention did not significantly differ between the two stents. Conformable covered double-layered and uncovered unfixed-cell braided stents were associated with different patterns of stent malfunction. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  15. Analysis of Flight of Near-Space Balloon

    Science.gov (United States)

    Miller, Zech; Evans, Austin; Seyfert, James; Leadlove, Kyle; Gumina, Kaitlyn; Martell, Eric

    2015-04-01

    In December 2014, the Electronics class at Millikin University launched a balloon designed to travel into the near-space region of the atmosphere. The balloon was equipped with an instrumentation package including a camera, accelerometer, barometric pressure sensor, temperature probes, as well as a system for tracking using an Automatic Packet Reporting System (APRS). The balloon was launched from Decatur, IL, and landed in Marysville, OH, nearly 320 miles away. The students then analyzed the data from the flight and compared results to expectations.

  16. Heat Transfer Model for Hot Air Balloons

    OpenAIRE

    Lladó Gambín, Adriana

    2016-01-01

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the mod...

  17. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  18. A clinical evaluation of endoscopically placed self-expanding metallic stents in patients with acute large bowel obstruction

    DEFF Research Database (Denmark)

    Pommergaard, H C; Vilmann, P; Jakobsen, H L

    2009-01-01

    BACKGROUND AND AIMS: Self-expanding metallic stents (SEMS) have since 1991 established themselves as an option in the treatment of large bowel obstruction. The aim of this study was to evaluate the use of SEMS in management of acute colorectal obstructions at a Danish Surgical Gastroenterology...

  19. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  20. Endoscopic palliation of patients with biliary obstruction caused by nonresectable hilar cholangiocarcinoma: efficacy of self-expandable metallic Wallstents

    NARCIS (Netherlands)

    Cheng, John L. S.; Bruno, Marco J.; Bergman, Jacques J.; Rauws, Erik A.; Tytgat, Guido N.; Huibregtse, Kees

    2002-01-01

    Background: The aim of this study was to evaluate the efficacy of an endoscopically inserted self-expandable metal stent for treatment of biliary obstruction caused by nonresectable hilar cholangiocarcinoma. Methods: Data on all patients with nonresectable hilar cholangiocarcinoma receiving

  1. Assessment of safety and efficacy of an indigenous self-expandable fully covered esophageal metal stent for palliation of esophageal cancer.

    Science.gov (United States)

    Padhan, R K; Nongthombam, S K; Venuthurimilli, A; Dhingra, R; Sahni, P; Garg, P K

    2016-01-01

    Patients with unresectable esophageal cancer require palliation for dysphagia. Placement of a self-expandable metal stent (SEMS) is the procedure of choice for palliation of dysphagia. To evaluate the safety and efficacy of an indigenous fully-covered SEMS in patients with esophageal cancer. Eligible patients with unresectable esophageal cancer requiring palliation for dysphagia were included in the study. An indigenous fully covered SEMS of appropriate length was placed under endoscopic and fluoroscopic guidance. Outcome measures assessed were adverse events and improvement in dysphagia. Twenty one patients (mean age 57.71±13.14 years; 17 males) were included. After stenting, dysphagia score decreased from 3.2+0.4 to 0.35+0.74 at 4 weeks. Adverse events included retrosternal pain, respiratory distress and aspiration pneumonia in 12, 2 and 1 patients respectively. Five patients required repeat stenting due to stent migration in 4 (following radiotherapy in 3) and tumour ingrowth in 1. There was primary stent malfunction in one patient. The median survival of patients was 140 (76-199) days, which was higher in those who received radiotherapy. The stent was reasonably safe and effective to relieve dysphagia due to unresectable esophageal cancer.

  2. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  3. Improved understanding of human anatomy through self-guided radiological anatomy modules.

    Science.gov (United States)

    Phillips, Andrew W; Smith, Sandy G; Ross, Callum F; Straus, Christopher M

    2012-07-01

    To quantifiably measure the impact of self-instructed radiological anatomy modules on anatomy comprehension, demonstrated by radiology, gross, and written exams. Study guides for independent use that emphasized structural relationships were created for use with two online radiology atlases. A guide was created for each module of the first year medical anatomy course and incorporated as an optional course component. A total of 93 of 96 eligible students participated. All exams were normalized to control for variances in exam difficulty and body region tested. An independent t-test was used to compare overall exam scores with respect to guide completion or incompletion. To account for aptitude differences between students, a paired t-test of each student's exam scores with and without completion of the associated guide was performed, thus allowing students to serve as their own controls. Twenty-one students completed no study guides; 22 completed all six guides; and 50 students completed between one and five guides. Aggregate comparisons of all students' exam scores showed significantly improved mean performance when guides were used (radiology, 57.8% [percentile] vs. 45.1%, P < .001; gross, 56.9% vs. 46.5%, P = .001; written, 57.8% vs. 50.2%, P = .011). Paired comparisons among students who completed between one and five guides demonstrated significantly higher mean practical exam scores when guides were used (radiology, 49.3% [percentile] vs. 36.0%, P = .001; gross, 51.5% vs. 40.4%, P = .005), but not higher written scores. Radiological anatomy study guides significantly improved anatomy comprehension on radiology, gross, and written exams. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  4. Introduction (Special Issue on Scientific Balloon Capabilities and Instrumentation)

    Science.gov (United States)

    Gaskin, Jessica A.; Smith, I. S.; Jones, W. V.

    2014-01-01

    In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3,000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science.) Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.

  5. The 6-month effectiveness of Internet-based guided self-help for depression in adults with Type 1 and 2 diabetes mellitus.

    Science.gov (United States)

    Ebert, D D; Nobis, S; Lehr, D; Baumeister, H; Riper, H; Auerbach, R P; Snoek, F; Cuijpers, P; Berking, M

    2017-01-01

    The aim of this research is to examine the 6-month effects of an Internet-based guided self-help intervention for comorbid depressive symptoms in people with diabetes. Participants (n = 260) with Type 1 or 2 diabetes and elevated depressive symptoms [Center for Epidemiological Studies Depression Scale (CES-D) ≥ 23] were randomly assigned to a guided Internet-based self-help intervention or a control condition (treatment as usual + online psychoeducation about depression). The primary outcome was a change in depressive symptom severity (CES-D) from baseline to 6-month follow-up. The secondary outcomes included numbers of people achieving treatment response (reliable change of depressive symptoms) and remission (CES-D ≤ 16), as well as the effects on glycaemic control, diabetes-related emotional distress and diabetes acceptance. Repeated measures analysis of variance examined between-group differences using intent-to-treat principles. Both conditions showed improvements in depression severity: intervention condition, d = 1.48 [95% confidence interval (95% CI): 1.21 to 1.76]; control condition d = 0.55 (95% CI: 0.30 to 0.80). Changes were significantly greater in the intervention condition with a large between-group effect size (d = 0.83, 95% CI: 0.57 to 1.08). Accordingly, effects on response [relative risk (RR) = 2.60 (95% CI: 2.01 to 3.36), P 1] and remission [RR = 3.36 (95% CI: 2.98 to 5.44), P 1] were in favour of the intervention group, as were differences in change in diabetes emotional distress (d = 0.50, 95% CI: 0.04 to 0.54), and physical and mental functioning [Short Form Health Survey (SF-12) Physical d = 0.27 (95% CI: 0.01 to 0.51) and SF-12 Mental d = 0.68 (95% CI: 0.11 to 0.40)]. The intervention group was not superior with regard to glycaemic control, diabetes self-management and diabetes acceptance. The trial indicates that Internet-based guided self-help treatments for depression in people with diabetes can have sustained effects on depressive

  6. The impact of balloon catheter dilation on frequency of sinus surgery in the United States

    Directory of Open Access Journals (Sweden)

    Holy CE

    2014-04-01

    Full Text Available Chantal E Holy,1 John M Ellison,1 Charles Schneider,1 Howard L Levine2,3 1Health Economics and Reimbursement, 2Medical Affairs, Acclarent Inc., a Johnson & Johnson Company, Menlo Park, CA, USA; 3Cleveland Nasal-Sinus and Sleep Center, Cleveland, OH, USA Purpose: Endoscopic sinus surgery for patients with chronic rhinosinusitis (CRS unresponsive to medical therapy has traditionally been performed under general anesthesia and in the operating room. Balloons for catheter dilation of paranasal sinuses were introduced in 2005, allowing sinus surgery to be safely performed either in the operating room or the office care setting, under local anesthesia. This change in care setting has raised concerns of overuse or expanded indications for sinus surgery. This study was thus designed to evaluate changes in surgical volumes in the United States, for the period 2006–2011, and to evaluate the impact of the sinus balloons on surgical practice. Methods: The MarketScan® Commercial Claims and Encounter Database was queried for the period 2006 to 2011 using CRS International Classification of Diseases, Ninth Revision codes (473.X and sinus surgery US-based Common Procedural Terminology (CPT codes (endoscopic sinus surgery: CPT codes 31254–31294 and 31299; balloon catheter dilation: CPT codes 31295–31297. MarketScan's projection methodology was applied to estimate the nationwide prevalence of CRS and the incidence of sinus surgery. Procedural case mix and total average payment per surgery were analyzed. Results: From 2006 to 2011, the yearly prevalence of CRS and sinus surgery volume remained flat with ~430 patients with CRS per 100,000 in the employer-sponsored insured population, of which ~117/100,000 underwent surgery. In 2006, 2.69 paranasal sinuses (95% confidence interval [95% CI]: 2.65–2.71 were treated during each individual sinus surgery, with an additional 1.11 nasal procedures (95% CI: 1.08–1.13 performed concurrently. By 2011, the

  7. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  8. Taking the Hot Air Out of Balloons.

    Science.gov (United States)

    Brinks, Virgil L.; Brinks, Robyn L.

    1994-01-01

    Describes how a teacher can give their students the challenge of designing and building model balloons or blimps. The project helps students learn the basics of balloon flight and what it really means to be "lighter than air." (PR)

  9. Paraplegia following intraaortic balloon circulatory assistance

    Directory of Open Access Journals (Sweden)

    Benício Anderson

    1999-01-01

    Full Text Available Intraaortic balloon counterpulsation is frequently used in patients experiencing severe ventricular dysfunction following maximal drug therapy. However, even with the improvement of percutaneous insertion techniques, the procedure has always been followed by vascular, infectious, and neurological complications. This article describes a case of paraplegia due to intraaortic balloon counterpulsation in the postoperative period of cardiac surgery.

  10. Self-expandable metallic stent placement for patients with inoperable esophageal carcinoma. Investigation of the influence of prior radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Ihara, Yuko; Murayama, Sadayuki; Toita, Takafumi; Utsunomiya, Takashi; Nagata, Osamu; Akamine, Tamaki; Ogawa, Kazuhiko; Adachi, Genki; Tanigawa, Noboru

    2006-01-01

    The aim of this study was to evaluate the efficacy and complications of self-expandable metallic stent placement for patients with inoperable esophageal carcinoma after radiotherapy and/or chemotherapy. We obtained data from 19 patients with advanced or recurrent esophageal carcinoma between 1996 and 2000. In all patients, a self-expandable metallic stent was placed under fluoroscopic guidance. Dysphagia before and after stent placement was graded. Complications after stent placement were also evaluated. Data were compared between patients with and without prior radiotherapy and/or chemotherapy. The procedure was technically successful in all but one patient. The dysphagia grade improved in all patients. No life-threatening complications occurred. The other major complications such as mediastinitis occurred in two patients, and pneumonia and funnel phenomenon occurred in one patient each. These patients had a history of radiotherapy and/or chemotherapy prior to stent placement. Eight of the twelve patients with prior radiotherapy and/or chemotherapy compared with one of seven patients without prior therapy had persistent chest pain, which was a statistically significant difference (P<0.05). Placement of self-expandable metallic stents was effective for patients with advanced or recurrent esophageal carcinoma. However, prior irradiation and/or chemotherapy increased the risk of persistent chest pain after stent placement. (author)

  11. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  12. Comparative study of balloon and metal olive dilators for endoscopic management of benign anastomotic rectal strictures: clinical and cost-effectiveness outcomes.

    Science.gov (United States)

    Xinopoulos, Dimitrios; Kypreos, Dimitrios; Bassioukas, Stefanos P; Korkolis, Dimitrios; Mavridis, Konstantinos; Scorilas, Andreas; Dimitroulopoulos, Dimitrios; Loukou, Argyro; Paraskevas, Emmanouel

    2011-03-01

    Postoperative anastomotic strictures frequently complicate colorectal resection. Currently, various endoscopic techniques are being employed in their management, but the establishment of an optimal therapeutic strategy is still pending. The purpose of our study is to compare through-the-scope (TTS) balloon dilators versus Eder-Puestow metal olive dilators in the treatment of postoperative benign rectal strictures, considering the clinical outcome and cost-effectiveness of each method. A total of 39 patients with benign anastomotic rectal stenosis were retrospectively studied. In group A, 15 patients underwent dilation with Eder-Puestow metal olives, while in group B 19 patients were treated by means of TTS balloon dilators. The technical and clinical success of dilation, complications, number of repeated sessions required, disease-free time intervals, and the overall cost of each procedure were evaluated. Dilations were technically successful in all patients. No major complications occurred in either group. The number of dilations needed, rate of stricture recurrence, and duration of stenosis-free time intervals were not statistically significantly different between the two groups. Both methods proved more effective in older patients, given the greater number of dilations required in younger patients of both groups and higher frequency of stricture relapse in younger balloon-dilated patients (median 64.00 years) compared with older ones (median 75.00 years) (p = 0.001). An indisputable advantage of the Eder-Puestow technique, compared with TTS balloon dilators, is the low cost of equipment (median 22.30 compared with 680 , respectively; p Puestow bougies or TTS balloon dilators. However, metal olivary tips seem to surpass balloon dilators when considering the obvious economical benefits of the first method.

  13. Guided Instruction Improves Elementary Student Learning and Self-Efficacy in Science

    Science.gov (United States)

    Hushman, Carolyn J.; Marley, Scott C.

    2015-01-01

    The authors investigated whether the amount of instructional guidance affects science learning and self-efficacy. Sixty 9- and 10-year-old children were randomly assigned to one of the following three instructional conditions: (a) guided instruction consisting of examples and student-generated explanations, (b) direct instruction consisting of a…

  14. Primary intestinal lymphangiectasia: A rare cause of diarrhea in adults diagnosed by capsule endoscopy and double balloon enteroscopy

    Directory of Open Access Journals (Sweden)

    Varun Gupta

    2014-01-01

    Full Text Available Primary intestinal lymphangiectasia (PIL or Waldmann′s disease is a rare protein-losing enteropathy presenting with diarrhea. The etiology and prevalence of PIL remain unknown. <200 cases have been reported in the literature so far. Diagnosis of intestinal lymphangiectasia is difficult as there are no serological or radiological tests available. Small bowel imaging modalities like capsule endoscopy and double balloon enteroscopy have increased the chances of diagnosis of PIL due to direct visualization of small bowel. Diagnosis is confirmed by characteristic histopathological finding, which includes dilated intestinal lymphatics with broadened villi of the small bowel. We report a case of a patient with chronic diarrhea who was extensively worked up before he was finally diagnosed to have PIL involving the small bowel by performing balloon enteroscopy-guided biopsy.

  15. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  16. New concepts for interplanetary balloons and blimps, particularly for Titan

    Science.gov (United States)

    Nott, J.

    This paper proposes novel approaches for balloons for planets Titan BALLUTE A balloon or blimp arriving at a planet or moon with an atmosphere might inflate falling under a parachute or after landing Neither is ideal In both cases the envelope must include qualities needed for inflation as well as those for flight A ballute BALLoon parachUTE could be used thus a ballute is like a hot air balloon with a large mouth Initially it fills by ram pressure descending through an atmosphere As proposed it would then be heated by solid propellant It would stop descending and float level with hot air lift It is now a perfect location for inflation without wind or movement through the atmosphere and away from the uncertainties of the surface A ballute could be used over several bodies in the solar system BALLOONS FOR LOW TEMPERATURES Flight in very low temperatures is also discussed Conditions are so different that it is useful to examine basic factors These apply for any planet with low temperature and weather calm enough for balloons or blimps First for terrestrial hot air balloons thermal radiation is usually the dominant way heat is lost But radiation rises with the 4th power of absolute temperature At Titan radiation will be one or two orders of magnitude smaller Also the dense atmosphere allows small balloons small temperature differences So convection is small It appears a hot air balloon can easily be heated by a radioactive source likely carried to make electricity Pinholes are not important in such a balloon

  17. Impact of guided reciprocal peer questioning on nursing students' self-esteem and learning.

    Science.gov (United States)

    Lakdizaji, Sima; Abdollahzadeh, Farahnaz; Hassankhanih, Hadi; Kalantari, Manizhe

    2013-07-01

    Self-esteem is essential for clinical judgments. Nursing students in clinical environments should make a bridge between theoretical education and clinical function. This study was aimed to survey the effect of guided questioning in peer groups on nursing students' self-esteem and clinical learning. In this quasi-experimental study, all nursing students in semester 4 (60) were selected. The autumn semester students (n = 28) were chosen as the control group, and the spring semester students (n = 32) as the experimental group. The experimental group underwent the course of cardiac medical surgical training by the Guided Reciprocal Peer Questioning. The control group was trained by lecture. After confirmation of the validity and reliability of tools including Rosenberg Self-esteem Scale and the researcher-made questionnaire, data were collected and analyzed by SPSS version 17.0. There was no significant difference concerning demographic and educational characteristics between the two groups. Mean score differences of self-esteem and learning were not significant before teaching, while they were significantly promoted after teaching in the experimental (P self-esteem and students' learning, can be applied alone or in combination with the other methods. Conducting this study for other students and for theoretical courses is suggested.

  18. Impact of guided reciprocal peer questioning on nursing students’ self-esteem and learning

    Science.gov (United States)

    Lakdizaji, Sima; Abdollahzadeh, Farahnaz; Hassankhanih, Hadi; Kalantari, Manizhe

    2013-01-01

    Background: Self-esteem is essential for clinical judgments. Nursing students in clinical environments should make a bridge between theoretical education and clinical function. This study was aimed to survey the effect of guided questioning in peer groups on nursing students’ self-esteem and clinical learning. Materials and Methods: In this quasi-experimental study, all nursing students in semester 4 (60) were selected. The autumn semester students (n = 28) were chosen as the control group, and the spring semester students (n = 32) as the experimental group. The experimental group underwent the course of cardiac medical surgical training by the Guided Reciprocal Peer Questioning. The control group was trained by lecture. After confirmation of the validity and reliability of tools including Rosenberg Self-esteem Scale and the researcher-made questionnaire, data were collected and analyzed by SPSS version 17.0. Results: There was no significant difference concerning demographic and educational characteristics between the two groups. Mean score differences of self-esteem and learning were not significant before teaching, while they were significantly promoted after teaching in the experimental (P self-esteem and students’ learning, can be applied alone or in combination with the other methods. Conducting this study for other students and for theoretical courses is suggested. PMID:24403923

  19. The Influence of Guided Error-Based Learning on Motor Skills Self-Efficacy and Achievement.

    Science.gov (United States)

    Chien, Kuei-Pin; Chen, Sufen

    2018-01-01

    The authors investigated the role of errors in motor skills teaching, specifically the influence of errors on skills self-efficacy and achievement. The participants were 75 undergraduate students enrolled in pétanque courses. The experimental group (guided error-based learning, n = 37) received a 6-week period of instruction based on the students' errors, whereas the control group (correct motion instruction, n = 38) received a 6-week period of instruction emphasizing correct motor skills. The experimental group had significantly higher scores in motor skills self-efficacy and outcomes than did the control group. Novices' errors reflect their schema in motor skills learning, which provides a basis for instructors to implement student-centered instruction and to facilitate the learning process. Guided error-based learning can effectively enhance beginners' skills self-efficacy and achievement in precision sports such as pétanque.

  20. Radioisotope treatment for benign strictures of non-vascular luminal organs

    International Nuclear Information System (INIS)

    Shin, Ji Hoon

    2006-01-01

    Tissue hyperplasia in one of the most frequently encountered complications when self-expanding stents are placed in benign non-vascular luminal organ strictures, thus causing of the lumen. The investigators postulated that ionizing irradiation could be applied to prevent restenosis caused by tissue hyperplasia in non-vascular luminal organs as it reduced coronary or peripheral arterial narrowing successfully. The authors combined β-irradiation using 188 Re-MAG 3 solution with balloon for animal and clinical studies because this new treatment approach had the advantages such as low penetration depth of β-ray, self-centering irradiation, and mechanical effect of balloon dilation over using γ-irradiation with afterloading devices. In this article, the concept and mechanism of radioisotope balloon dilation, and animal and clinical studies using radioisotope balloon dilation are reviewed

  1. OligArch: A software tool to allow artificially expanded genetic information systems (AEGIS to guide the autonomous self-assembly of long DNA constructs from multiple DNA single strands

    Directory of Open Access Journals (Sweden)

    Kevin M. Bradley

    2014-08-01

    Full Text Available Synthetic biologists wishing to self-assemble large DNA (L-DNA constructs from small DNA fragments made by automated synthesis need fragments that hybridize predictably. Such predictability is difficult to obtain with nucleotides built from just the four standard nucleotides. Natural DNA's peculiar combination of strong and weak G:C and A:T pairs, the context-dependence of the strengths of those pairs, unimolecular strand folding that competes with desired interstrand hybridization, and non-Watson–Crick interactions available to standard DNA, all contribute to this unpredictability. In principle, adding extra nucleotides to the genetic alphabet can improve the predictability and reliability of autonomous DNA self-assembly, simply by increasing the information density of oligonucleotide sequences. These extra nucleotides are now available as parts of artificially expanded genetic information systems (AEGIS, and tools are now available to generate entirely standard DNA from AEGIS DNA during PCR amplification. Here, we describe the OligArch (for "oligonucleotide architecting" software, an application that permits synthetic biologists to engineer optimally self-assembling DNA constructs from both six- and eight-letter AEGIS alphabets. This software has been used to design oligonucleotides that self-assemble to form complete genes from 20 or more single-stranded synthetic oligonucleotides. OligArch is therefore a key element of a scalable and integrated infrastructure for the rapid and designed engineering of biology.

  2. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive......, probably caused by ischemic conditions developed before stent-decompression of the colon was revealed during the operation. The patient died in the postoperative course. We discuss the observation of patients treated with self-expanding metal stents based on the selection-strategy used to allocate patients...

  3. Comparison of Self-Expanding Polyethylene Terephthalate and Metallic Stents Implanted in Porcine Iliac Arteries

    International Nuclear Information System (INIS)

    Wilczek, Krzysztof; Scheerder, Ivan de; Wang Kai; Verbeken, Eric; Piessens, Jan

    1996-01-01

    Purpose: Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). Methods: Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. Results: Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). Conclusion: PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents

  4. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p day device safety, success, and efficacy were noted in 79.1%, 89...

  5. Aviation investigation report : hard landing : fuel leak and fire[Sundance Balloons International Firefly 12B (hot air balloon) C-FNVM, Winnipeg, Manitoba, 15 nm NE, 11 August 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-08-15

    This investigation report discussed an incident in Winnipeg in which a hot air balloon attempting to land during strong winds was dragged on its side for approximately 700 feet. The balloon's burners struck the ground as the balloon came to a stop, after which a propane leak occurred. An intense, uncontrolled fire ensued as balloon passengers were exiting from the partially-inverted basket. The pilot and 2 passengers suffered serious injuries, while another 4 passengers suffered minor injuries. The balloon's 2 propane tanks and a fire extinguisher canister exploded during the fire, which destroyed the balloon's basket. The rigging of the balloon was examined and no failures were discovered. Pressure tests showed that the balloon's hoses started leaking at the crimped sleeve fittings at 150 psi. While the pilot had been informed of potentially heavy winds and thunderstorms, changes in wind speed and direction occurred earlier than the forecasted time of 10:00. It was concluded that standards are needed to ensure balloon cabin safety. Balloon operators do not currently require the use of protective helmets or gloves in case of dragged landings. A review will be conducted to address the issue of proposed emergency fuel shut-offs for balloons carrying fare-paying passengers. 2 figs.

  6. Volunteer Guides in Nature Reserves: Exploring Environmental Educators' Perceptions of Teaching, Learning, Place and Self

    Science.gov (United States)

    Evans, Emily; Ching, Cynthia Carter; Ballard, Heidi L.

    2012-01-01

    In the following case study, we examine the interplay between self-perception, environmental perception, and the interests and practice of volunteer trail guides who were recruited to provide educational services for visitors to a natural reserve in Northern California. Through semi-structured interviews with 15 guides and observations of training…

  7. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  8. Balloon catheter dilation of benign esophageal stenosis in children

    International Nuclear Information System (INIS)

    Fan Guoping; Yu Juming; Zhong Weixing; Zhu Ming; Wu Yeming; Shi Chengren

    2001-01-01

    Objective: To evaluate the methods and effect of balloon catheter dilation of benign esophageal stenosis in children. Methods: 9 cases had an anastomotic stenosis after surgical correction of esophageal atresia; 11 cases of esophageal stenosis due to ingestion of caustics; one case had an lower esophageal stenosis after Nissen surgery and one case after gastro-esophagoplasty. Age ranged from 17 days to 7 years. Each case had a barium esophagram before balloon dilation. The balloon size varied from 3 to 10 mm in diameter. Results: 21 cases were successful after dilation of balloon catheter. There were no esophageal perforation and complications. The satisfactory results maintained from six months to thirty months. Conclusions: Balloon catheter dilation is a simple, safe and reliable method for the treatment of benign esophageal strictures in children as the first choice

  9. Static and quasi-static analysis of lobed-pumpkin balloon

    Science.gov (United States)

    Nakashino, Kyoichi; Sasaki, Makoto; Hashimoto, Satoshi; Saito, Yoshitaka; Izutsu, Naoki

    The present study is motivated by the need to improve design methodology for super pressure balloon with 3D gore design concept, currently being developed at the Scientific Balloon Center of ISAS/JAXA. The distinctive feature of the 3-D gore design is that the balloon film has excess materials not only in the circumferential direction but also in the meridional direction; the meridional excess is gained by attaching the film boundaries to the corresponding tendons of a shorter length with a controlled shortening rate. The resulting balloon shape is a pumpkin-like shape with large bulges formed between adjacent tendons. The balloon film, when fully inflated, develops wrinkles in the circumferential direction over its entire region, so that the stresses in the film are limited to a small amount of uniaxial tension in the circumferential direction while the high meridional loads are carried by re-enforced tendons. Naturally, the amount of wrinkling in the film is dominated by the shortening rate between the film boundaries and the tendon curve. In the 3-D gore design, as a consequence, the shortening rate becomes a fundamental design parameter along with the geometric parameters of the gore. In view of this, we have carried out a series of numerical study of the lobed-pumpkin balloon with varying gore geometry as well as with varying shortening rate. The numerical simula-tions were carried out with a nonlinear finite element code incorporating the wrinkling effect. Numerical results show that there is a threshold value for the shortening rate beyond which the stresses in the balloon film increases disproportionately. We have also carried out quasi-static simulations of the inflation process of the lobed-pumpkin balloon, and have obtained asymmetric deformations when the balloon films are in uniaxial tension state.

  10. The effectiveness of manual-guided, problem-solving-based self-learning programme for family caregivers of people with recent-onset psychosis: A randomised controlled trial with 6-month follow-up.

    Science.gov (United States)

    Chien, Wai Tong; Yip, Annie L K; Liu, Justina Y W; McMaster, Terry W

    2016-07-01

    Family intervention for psychotic disorders is an integral part of psychiatric treatment with positive effects on patients' mental state and relapse rate. However, the effect of such family-based intervention on caregivers' psychological distress and well-being, especially in non-Western countries, has received comparatively much less attention. To test the effects of guided problem-solving-based manual-guided self-learning programme for family caregivers of adults with recent-onset psychosis over a 6-month period of follow-up, when compared with those in usual family support service. A single-centre randomised controlled trial, which was registered at ClinicalTrials.gov (NCT02391649), with a repeated-measures, two-arm (parallel-group) design. One main psychiatric outpatient clinic in the New Territories of Hong Kong. A random sample of 116 family caregiverss of adult outpatients with recent-onset psychosis. Following pre-test measurement, caregivers were assigned randomly to one of two study groups: a 5-month self-help, problem-solving-based manual-guided self-learning (or bibliotherapy) programme (in addition to usual care), or usual family support service only. Varieties of patient and caregiver health outcomes were assessed and compared at baseline and at 1-week and 6-month post-intervention. One hundred and eleven (96%) caregivers completed the 6-month follow-up (two post-tests); 55 of them (95%) completed ≥4 modules and attended ≥2 review sessions (i.e., 75% of the intervention). The family participants' mean age was about 38 years and over 64% of them were female and patient's parent or spouse. Multivariate analyses of variance indicated that the manual-guided self-learning group reported significantly greater improvements than the usual care group in family burden [F(1,110)=6.21, p=0.006] and caregiving experience [F(1,110)=6.88, p=0.0004], and patients' psychotic symptoms [F(1,110)=6.25, p=0.0003], functioning [F(1,110)=7.01, p=0.0005] and number of

  11. An Overview of Current and Future Stratospheric Balloon Mission Capabilities

    Science.gov (United States)

    Smith, Michael

    The modern stratospheric balloon has been used for a variety of missions since the late 1940's. Capabilities of these vehicles to carry larger payloads, fly to higher altitudes, and fly for longer periods of time have increased dramatically over this time. In addition to these basic performance metrics, reliability statistics for balloons have reached unprecedented levels in recent years. Balloon technology developed in the United States in the last decade has the potential to open a new era in economical space science using balloons. As always, the advantage of the balloon platform is the fact that missions can be carried out at a fraction of the cost and schedule of orbital missions. A secondary advantage is the fact that instruments can be re-flown numerous times while upgrading sensor and data processing technologies from year to year. New mission capabilities now have the potential for enabling ground breaking observations using balloons as the primary platform as opposed to a stepping stone to eventual orbital observatories. The limit of very high altitude balloon missions will be explored with respect to the current state of the art of balloon materials and fabrication. The same technological enablers will also be applied to possibilities for long duration missions at mid latitudes with payloads of several tons. The balloon types and their corresponding mission profiles will be presented in a performance matrix that will be useful for potential scientific users in planning future research programs.

  12. The Effects of Webopac Self Training Tool with Guided Exploration on Information Literacy Skills among First Year Degree Students

    Science.gov (United States)

    Ismail, Mohd Nasir; Mamat, Nurfaezah; Jamaludin, Adnan

    2018-01-01

    The purpose of this study is to investigate effects of WebOPAC Self Training Tool with Guided Exploration (WSTTG), WebOPAC Self Training Tool with non-guided exploration (WSTT) and Traditional (T) groups as the learning strategies on information literacy (IL) skills standards among first year degree students in Malaysian public university. The…

  13. Photocatalytic self-cleaning poly(L-lactide) materials based on a hybrid between nanosized zinc oxide and expanded graphite or fullerene

    Energy Technology Data Exchange (ETDEWEB)

    Virovska, Daniela [Laboratory of Bioactive Polymers, Institute of Polymers, Bulgarian Academy of Sciences, Acad. G. Bonchev St., bl. 103A, BG-1113 Sofia (Bulgaria); Paneva, Dilyana, E-mail: panevad@polymer.bas.bg [Laboratory of Bioactive Polymers, Institute of Polymers, Bulgarian Academy of Sciences, Acad. G. Bonchev St., bl. 103A, BG-1113 Sofia (Bulgaria); Manolova, Nevena [Laboratory of Bioactive Polymers, Institute of Polymers, Bulgarian Academy of Sciences, Acad. G. Bonchev St., bl. 103A, BG-1113 Sofia (Bulgaria); Rashkov, Iliya, E-mail: rashkov@polymer.bas.bg [Laboratory of Bioactive Polymers, Institute of Polymers, Bulgarian Academy of Sciences, Acad. G. Bonchev St., bl. 103A, BG-1113 Sofia (Bulgaria); Karashanova, Daniela [Institute of Optical Materials and Technologies, Bulgarian Academy of Sciences, Acad. G. Bonchev St., bl. 109, BG-1113 Sofia (Bulgaria)

    2016-03-01

    New self-cleaning materials of polymer fibers decorated with a hybrid between nanosized zinc oxide and expanded graphite (EG) or fullerene (C{sub 60}) were obtained. The new materials were prepared by applying electrospinning in conjunction with electrospraying. Poly(L-lactide) (PLA) was selected as a biocompatible and (bio)degradable polymer carrier. PLA solution was electrospun in combination with electrospraying of a suspension that contained the ZnO/EG or ZnO/C{sub 60} hybrid. Mats with different content of EG or C{sub 60} were obtained. The new materials were characterized by scanning and transmission electron microscopy (SEM and TEM), energy-dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and X-ray diffraction analysis (XRD). The photocatalytic activity of the materials was evaluated by using model dyes. The formation of a hybrid between ZnO and EG led to enhancement of the photocatalytic activity of the mats at ZnO/EG weight ratios of 90/10 and 85/15. Increase in the photocatalytic activity of the ZnO-containing mats was also achieved by the formation of a hybrid between ZnO and C{sub 60} at a fullerene content of 0.5 and 1.0 wt.% in respect to ZnO weight. The new materials exhibited antibacterial activity as evidenced by the performed studies against Staphylococcus aureus. - Highlights: • New self-cleaning materials are fabricated by electrospinning/electrospraying. • PLA fibers decorated with nanosized ZnO/EG or ZnO/C{sub 60} hybrid are obtained. • Their photocatalytic activity is enhanced as compared to fibers with bare ZnO. • The new materials can be used repeatedly for degradation of MB and RR dyes. • The new self-cleaning materials exhibit antibacterial activity against S. aureus.

  14. Photocatalytic self-cleaning poly(L-lactide) materials based on a hybrid between nanosized zinc oxide and expanded graphite or fullerene

    International Nuclear Information System (INIS)

    Virovska, Daniela; Paneva, Dilyana; Manolova, Nevena; Rashkov, Iliya; Karashanova, Daniela

    2016-01-01

    New self-cleaning materials of polymer fibers decorated with a hybrid between nanosized zinc oxide and expanded graphite (EG) or fullerene (C_6_0) were obtained. The new materials were prepared by applying electrospinning in conjunction with electrospraying. Poly(L-lactide) (PLA) was selected as a biocompatible and (bio)degradable polymer carrier. PLA solution was electrospun in combination with electrospraying of a suspension that contained the ZnO/EG or ZnO/C_6_0 hybrid. Mats with different content of EG or C_6_0 were obtained. The new materials were characterized by scanning and transmission electron microscopy (SEM and TEM), energy-dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and X-ray diffraction analysis (XRD). The photocatalytic activity of the materials was evaluated by using model dyes. The formation of a hybrid between ZnO and EG led to enhancement of the photocatalytic activity of the mats at ZnO/EG weight ratios of 90/10 and 85/15. Increase in the photocatalytic activity of the ZnO-containing mats was also achieved by the formation of a hybrid between ZnO and C_6_0 at a fullerene content of 0.5 and 1.0 wt.% in respect to ZnO weight. The new materials exhibited antibacterial activity as evidenced by the performed studies against Staphylococcus aureus. - Highlights: • New self-cleaning materials are fabricated by electrospinning/electrospraying. • PLA fibers decorated with nanosized ZnO/EG or ZnO/C_6_0 hybrid are obtained. • Their photocatalytic activity is enhanced as compared to fibers with bare ZnO. • The new materials can be used repeatedly for degradation of MB and RR dyes. • The new self-cleaning materials exhibit antibacterial activity against S. aureus.

  15. An analysis of the deployment of a pumpkin balloon at Mars

    Science.gov (United States)

    Rand, J. L.; Phillips, M. L.

    2004-01-01

    The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, where the radius used to determine the stress is determined by the volume of the balloon, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. A suitable superpressure balloon has been designed using this technology which will carry 2 kg in the atmosphere of Mars. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a 10 kg system suspended at the nadir of the balloon. As the system falls toward the surface of the planet, helium gas is transferred into the balloon, forming a partially inflated system very similar to an ascending zero pressure balloon. This analysis incorporates the flow of the planetary gas around the inflating balloon which alters the pressure distribution and shape. As a result, stresses are seen to increase beyond the design values which will require the balloon to be redesigned to accommodate this type of dynamic deployment.

  16. False coronary dissection with the new Monorail angioplasty balloon catheter.

    Science.gov (United States)

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  17. Malignant inferior vena cava obstruction involving right atrium. Palliative treatment with self expandable metallic stent

    International Nuclear Information System (INIS)

    Shao Guoliang; Wang Jianhua; Zhou Kangrong; Yan Zhiping

    2001-01-01

    Objective: To investigate the safety and efficacy of placement of self-expandable metallic stent within right atrium and inferior vena cava (ICV) in patients with malignant ICV obstruction involving right atrium. Methods: There were 5 male patients with advanced hepatocellular carcinoma, aged from 42 to 65 years (mean 56.3 years). The malignancies invaded right atrium and ICV simultaneously, and caused obstruction of ICV. These patients presented symptoms and signs of obstruction of ICV such as hepatomegaly, ascites, edema of lower extremities. 'Z' type stainless steel stents (7.5-10.0 cm in length and 2.5 cm in diameter) were selected for these patients. Part (1.0-3.0 cm in length) of stent was placed in right atrium and the rest was in ICV. Results: All of stents were placed successfully and obstructed ICV reopened. The symptoms of obstruction of ICV relieved or disappeared. There were no recurrence of symptoms of obstruction of ICV and any cardiac complication related to placement of stents in follow-up period (67-188 days). Conclusion: Placement of self-expandable metallic stent within right atrium and ICV in treatment of patients with malignant ICV obstruction involving right atrium is one of the safe and effective methods

  18. Self-Expanding Metal Stents Improve Swallowing and Maintain Nutrition During Neoadjuvant Therapy for Esophageal Cancer.

    Science.gov (United States)

    Smith, Zachary L; Gonzaga, Jason E; Haasler, George B; Gore, Elizabeth M; Dua, Kulwinder S

    2017-06-01

    Patients with locally advanced esophageal cancer can have significant dysphagia. Nutritional support during neoadjuvant therapy is often delivered via nasoenteric or percutaneous feeding tubes. These approaches do not allow for per-oral feeding. Evaluate the safety and efficacy of fully covered self-expanding metal esophageal stents for nutritional support during neoadjuvant therapy. This was a pilot, prospective study at a single tertiary center. From March 2012 to May 2013, consecutive patients with esophageal cancer eligible for neoadjuvant therapy were enrolled. Metal stents were placed prior to starting neoadjuvant therapy. Data were collected at baseline and predetermined intervals until an endpoint (surgery or disease progression). Outcomes included dysphagia grade, satisfaction of swallowing score, nutritional status (weight, serum albumin), impact on surgery, and adverse events. Fourteen stents were placed in 12 patients (59.1 ± 9.5 years, 11 men, 1 woman). Dysphagia grade (pre 3.4 ± 0.5 vs post 0.2 ± 0.4, p esophageal cancer, self-expanding metal stents are safe and effective in relieving dysphagia and maintaining nutrition. They allow patients to eat orally, thereby improving patient satisfaction. The presence of an in situ stent did not interfere with surgery.

  19. Placement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.

    Science.gov (United States)

    Song, Ho-Young; Kim, Choung Soo; Jeong, In Gab; Yoo, Dalsan; Kim, Jin Hyoung; Nam, Deok Ho; Bae, Jae-Ik; Park, Jung-Hoon

    2013-03-01

    To evaluate the technical feasibility and clinical effectiveness of retrievable self-expandable metallic stents with barbs in patients with obstructive prostate cancer. Retrievable self-expandable metallic stents with eight barbs each were inserted into eight consecutive patients with obstructive prostate cancer. Patient ages ranged from 55 to 76 years (mean, 69 years). All eight patients had previously received hormone therapy, and three had undergone palliative transurethral prostatectomy. Stents were removed using a 21-F stent removal set if they caused complications. Stent placement was technically successful and well tolerated in all patients. One had severe incontinence, which improved spontaneously, and two had gross haematuria, which disappeared spontaneously within 4 days. Peak urine flow rates and post-void residual urine volumes 1 month after stent placement were 5.6-10.2 ml/s (mean, 8.3 ml/s), and 5-45 ml (mean, 27 ml), respectively. During a mean follow-up of 192 days (range, 39-632 days), one patient required stent removal after 232 days because of stone formation within the stent. No further intervention was required because the mass improved after stent removal. These preliminary results suggest that retrievable stents with eight barbs are both feasible to place and effective in patients with obstructive prostate cancer.

  20. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1988-01-01

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  1. Self-expandable medical memorial metallic stent with 125I seeds for the treatment of esophageal carcinoma: a retrospective analysis

    International Nuclear Information System (INIS)

    Zhang Shuo; Lu Bin

    2011-01-01

    Objective: To discuss the curative effect and safety of the implantation of self-expandable medical memorial metallic stent with 125 I seeds for the treatment of advanced esophageal carcinomas. Methods: Implantation of self-expandable medical memorial metallic stent with 125 I seeds was performed in 32 patients with advanced esophageal canner. The clinical data were retrospectively analyzed. The technical success rate, the operation time, the immediate and mid-term effectiveness, the survival time, the complications, the body weight, the blood picture, the immune indexes, the average hospitalization days and hospitalization expenses were analyzed. Results: The average operation time was (18±5) minutes. Successful stent implantation was achieved in all 32 patients (100%). No 125 I seeds fell off during the procedure. The remission rate of dysphagia was 100%. Esophageal restenosis occurred in four patients, and displacement of the stent was seed in one patient. One month after the treatment, 90% of patients had a Karnofsky performance score over 60. The mean survival time was (8.7±6.6) months. The average hospitalization time was (7.8±3.7) days and the mean hospitalization cost was (12±3) thousand Chinese Yuan. Conclusion: For the treatment of esophageal carcinomas, the implantation of self-expandable medical memorial metallic stent with 125 I seeds is safe, effective and simple. This treatment can markedly improve the symptom of dysphagia and significantly prolong the patient's survival time. (authors)

  2. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    Science.gov (United States)

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  3. Intense-proton-beam transport through an insulator beam guide

    International Nuclear Information System (INIS)

    Hanamori, Susumu; Kawata, Shigeo; Kikuchi, Takashi; Fujita, Akira; Chiba, Yasunobu; Hikita, Taisuke; Kato, Shigeru

    1998-01-01

    In this paper we study intense-proton-beam transport through an insulator guide. In our previous papers (Jpn. J. Appl. Phys. 34 (1995) L520, Jpn. J. Appl. Phys. 35 (1996) L1127) we proposed a new system for intense-electron-beam transport using an insulator guide. In contrast to the electron beam, an intense-proton beam tends to generate a virtual anode, because of the large proton mass. The virtual anode formation at the initial stage is prevented by prefilled plasma in this system. During and after this, electrons are extracted from the plasma generated at the insulator surface by the proton beam space charge and expand over the transport area. The proton beam charge is effectively neutralized by the electrons. Consequently, the proton beam propagates efficiently through the insulator beam guide. The electron extraction is self-regulated by the net space charge of the proton beam. (author)

  4. Numerical research on the thermal performance of high altitude scientific balloons

    International Nuclear Information System (INIS)

    Dai, Qiumin; Xing, Daoming; Fang, Xiande; Zhao, Yingjie

    2017-01-01

    Highlights: • A model is presented to evaluate the IR radiation between translucent surfaces. • Comprehensive ascent and thermal models of balloons are established. • The effect of IR transmissivity on film temperature distribution is unneglectable. • Atmospheric IR radiation is the primary thermal factor of balloons at night. • Solar radiation is the primary thermal factor of balloons during the day. - Abstract: Internal infrared (IR) radiation is an important factor that affects the thermal performance of high altitude balloons. The internal IR radiation is commonly neglected or treated as the IR radiation between opaque gray bodies. In this paper, a mathematical model which considers the IR transmissivity of the film is proposed to estimate the internal IR radiation. Comprehensive ascent and thermal models for high altitude scientific balloons are established. Based on the models, thermal characteristics of a NASA super pressure balloon are simulated. The effects of film IR property on the thermal behaviors of the balloon are discussed in detail. The results are helpful for the design and operation of high altitude scientific balloons.

  5. Energizing Subject Guide Service with Web 2.0

    Directory of Open Access Journals (Sweden)

    Sheau-Hwang Chang

    2014-06-01

    Full Text Available This article will use LibGuides as an example to illustrate how a Web 2.0 platform can energize the subject guide service and give librarians an edge in expanding their roles. Topics to be discussed will include a brief introduction to LibGuides and its capabilities to energize subject guide creation, how it has been used by academic libraries, how it is used in Maxwell Library in expanding librarian's role, and finally its implications on librarianship.

  6. Guide to software export

    CERN Document Server

    Philips, Roger A

    2014-01-01

    An ideal reference source for CEOs, marketing and sales managers, sales consultants, and students of international marketing, Guide to Software Export provides a step-by-step approach to initiating or expanding international software sales. It teaches you how to examine critically your candidate product for exportability; how to find distributors, agents, and resellers abroad; how to identify the best distribution structure for export; and much, much more!Not content with providing just the guidelines for setting up, expanding, and managing your international sales channels, Guide to Software

  7. Adjustable continence balloons

    DEFF Research Database (Denmark)

    Kjær, Line; Fode, Mikkel; Nørgaard, Nis

    2012-01-01

    Abstract Objective. This study aimed to evaluate the results of the Danish experience with the ProACT urinary continence device inserted in men with stress urinary incontinence. Material and methods. The ProACT was inserted in 114 patients. Data were registered prospectively. The main endpoints...... in urinary leakage > 50% was seen in 72 patients (80%). Complications were seen in 23 patients. All of these were treated successfully by removal of the device in the outpatient setting followed by replacement of the device. Another eight patients had a third balloon inserted to improve continence further....... Fourteen patients (12%) ended up with an artificial sphincter or a urethral sling. Sixty patients (63%) experienced no discomfort and 58 (61%) reported being dry or markedly improved. Overall, 50 patients (53%) reported being very or predominantly satisfied. Conclusions. Adjustable continence balloons seem...

  8. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio

    2014-01-01

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  9. [Application of temporary balloon blocking technique in bone tumors surgery under the aid of CT angiography].

    Science.gov (United States)

    Fang, Cheng; Hu, Yongcheng; Huang, Hongchao; Xia, Qun; Chen, Xiaopeng; Yuan, Binbin; He, Xin; Wang, Peng

    2014-10-01

    To study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. A retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. The CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545 ± 0.248) cm and (1.060 ± 0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818 ± 1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months

  10. Analysis of current diffusive ballooning mode

    International Nuclear Information System (INIS)

    Yagi, M.; Azumi, M.; Itoh, K.; Itoh, S.; Fukuyama, A.

    1993-04-01

    The current diffusive ballooning mode is analysed in the tokamak plasma. This mode is destabilized by the current diffusivity (i.e., the electron viscosity) and stabilized by the thermal conductivity and ion viscosity. By use of the ballooning transformation, the eigenmode equation is solved. Analytic solution is obtained by the strong ballooning limit. Numerical calculation is also performed to confirm the analytic theory. The growth rate of the mode and the mode structure are analysed. The stability boundary is derived in terms of the current diffusivity, thermal conductivity, ion viscosity and the pressure gradient for the given shear parameter. This result is applied to express the thermal conductivity in terms of the pressure gradient, magnetic configurational parameters (such as the safety factor, shear and aspect ratio) and the Prandtl numbers. (author)

  11. Ballooning mode stability for self-consistent pressure and current profiles at the H-mode edge

    International Nuclear Information System (INIS)

    Miller, R.L.; Lin-Liu, Y.R.; Osborne, T.H.; Taylor, T.S.

    1997-11-01

    The edge pressure gradient (H-mode pedestal) for computed equilibria in which the current density profile is consistent with the bootstrap current may not be limited by the first regime ballooning limit. The transition to second stability is easier for: higher elongation, intermediate triangularity, larger ratio, pedestal at larger radius, narrower pedestal width, higher q 95 , and lower collisionality

  12. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  13. Effects of the Temporary Placement of a Self-Expandable Metallic Stent in Benign Pyloric Stenosis

    OpenAIRE

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-01-01

    Background/Aims The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Methods Twenty-two patients with benign sten...

  14. Design and evaluation of a continuum robot with extendable balloons

    Directory of Open Access Journals (Sweden)

    E. Y. Yarbasi

    2018-02-01

    Full Text Available This article presents the design and preliminary evaluation of a novel continuum robot actuated by two extendable balloons. Extendable balloons are utilized as the actuation mechanism of the robot, and they are attached to the tip from their slack sections. These balloons can extend very much in length without having a significant change in diameter. Employing two balloons in an axially extendable, radially rigid flexible shaft, radial strain becomes constricted, allowing high elongation. As inflated, the balloons apply a force on the wall of the tip, pushing it forward. This force enables the robot to move forward. The air is supplied to the balloons by an air compressor and its flow rate to each balloon can be independently controlled. Changing the air volumes differently in each balloon, when they are radially constricted, orients the robot, allowing navigation. Elongation and force generation capabilities and pressure data are measured for different balloons during inflation and deflation. Afterward, the robot is subjected to open field and maze-like environment navigation tests. The contribution of this study is the introduction of a novel actuation mechanism for soft robots to have extreme elongation (2000 % in order to be navigated in substantially long and narrow environments.

  15. Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.

    Science.gov (United States)

    Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko

    2016-12-01

    Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.

  16. Supporting student skill development in undergraduate research experiences through the development of a self-reflection guide

    Science.gov (United States)

    Hubenthal, M.; Brudzinski, M.

    2016-12-01

    There has been an increased emphasis on documenting the benefits of participating in undergraduate research opportunities (URO) and developing an understanding of the factors that influence these benefits. While tools to effectively measure the behavior, attitude, skills, interest, and/or knowledge (BASIK) that result from UROs have matured, little focus has been placed on developing practical tools and strategies to support students and mentors as they work to develop the BASIK being measured. Viewed through the lens of constructivism, a URO can be examined as a cognitive apprenticeship (CA) where learning occurs through several key methods: modeling, coaching, scaffolding, articulation, reflection, and exploration. In a study of UROs as CA, Feldman et al., (2013) found reflection to be one of the least commonly initiated methods employed by interns and mentors, and concluded, "there is need for professors to be more proactive in helping their students gain intellectual proficiency". This work, in its pilot stages, seeks to address this gap through the development of an intern self-reflection guide and implementation plan to further increase students' skill development. The guide is being developed based on IRIS's existing self-reflection tool. However, it has recently been revised to bring its constructs and items into better alignment with those of the Undergraduate Research Student Self-Assessment (URSSA) tool. The URSSA was selected because it is designed to measure skills and has recently undergone a validation study. In addition, it serves as the basis for the development of a new tool, the NSF Biology REU CORE. The revised self-reflection guide and protocol were piloted this summer in IRIS Summer REU program. The alignment between the constructs of the URSSA and the self-reflection guide will be presented along with findings from the 2016 program evaluation. Future development of the intervention will include a validation of the items on the self

  17. Development of radioactive 166Ho-coated balloon and its dose estimation

    International Nuclear Information System (INIS)

    Park, K. B.; Kim, K. H.; Hong, Y. D.; Park, E. W.

    2000-01-01

    The use of balloon with radioisotope is a promising method to prevent restenosis after transluminal coronary arterial angioplasty or stent implantation. In this study, we have developed a new radioactive coated balloon, which is prepared by coating the surface of existing balloon with 166 Ho instead of being filled with beta sources which emit high energy beta-particles for the purpose of the delivery of sufficient radiation to the vessel wall. To estimate the safety of 166 Ho-coated balloon, leaching test and radiation resistance test of the balloon were performed. The absorbed dose distributions around the 166 Ho-coated balloon were estimated by means of Monte Carlo simulation and the initial activities for optimal therapeutic regimen were determined on the basis of this results

  18. Mapping Self-Guided Learners' Searches for Video Tutorials on YouTube

    Science.gov (United States)

    Garrett, Nathan

    2016-01-01

    While YouTube has a wealth of educational videos, how self-guided learners use these resources has not been fully described. An analysis of search engine queries for help with the use of Microsoft Excel shows that few users search for specific features or functions but instead use very general terms. Because the same videos are returned in…

  19. Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jinhe [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Teng Gaojun [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)]. E-mail: gjteng@vip.sina.com; Zhu Guangyu [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Shicheng [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Deng Gang [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Jie [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)

    2007-02-15

    Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal segment in all rabbits. Neither {sup 125}I seeds dislodged from the stent during the deployment, nor they did during the follow-up period. The greatest (16.2 Gy) absorbed dose was found in the tissue 10 mm from {sup 125}I seeds at 8 weeks. Slight epithelial hyperplasia on the stent surface and submucosal inflammatory process developed at 2 weeks, which reached the peak at 8 weeks after the procedure. Significant thickness of the esophageal muscular layer was found at 8 weeks only in the groups with {sup 125}I seeds. On radiologic follow-up, moderate strictures on both ends of the stents developed at 4 weeks and became severe at 8 weeks after the procedure in all groups. Conclusion: Deployment of a self-expandable stent loaded with {sup 125}I seeds is technically feasible and safe within the first 8 weeks. Acute and subacute radiotolerance of the treated esophagus and its adjacent tissues by {sup 125}I seeds is well preserved in a healthy rabbit model.

  20. The Impact of Guided Student-Generated Questioning on Chemistry Achievement and Self-Efficacy of Elementary Preservice Teachers

    Science.gov (United States)

    Moseley, Christine; Bonner, Emily; Ibey, Marilyn

    2016-01-01

    This study investigated the use of Guided Student-Generated Questioning (GSGQ) as a metacognitive instructional strategy to increase chemistry achievement and self-efficacy of elementary preservice teachers. The Chemistry Self-Efficacy Scale (CSES), modified from the Biology Self-Efficacy Scale (BSES),was used to determine elementary preservice…