WorldWideScience

Sample records for balloon occlusion

  1. Balloon occlusion of the internal iliac arteries in the multidisciplinary management of placenta percreta

    DEFF Research Database (Denmark)

    Clausen, Caroline; Stensballe, Jakob; Albrechtsen, Charlotte K;

    2013-01-01

    Objective. To evaluate our experience with prophylactic balloon occlusion of the internal iliac arteries as a part of a multidisciplinary algorithm for the management of placenta percreta. Design. Consecutive case series. Setting. Rigshospitalet, Copenhagen University Hospital, Denmark. Sample....... Prophylactic balloon occlusion of the internal iliac arteries as part of a multidisciplinary algorithm allowed for a safe management of all cases in our consecutive series of 17 women with placenta percreta. However, intraoperative blood loss and transfusion requirements were significant. We have therefore...... decided to modify our multidisciplinary algorithm to include balloon occlusion of the common iliac arteries rather than the internal iliac arteries....

  2. Balloon Occlusion Types in the Treatment of Coronary Perforation during Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Xiangfei Wang

    2014-01-01

    Full Text Available Coronary artery perforation is an uncommon complication in patients with coronary heart disease undergoing percutaneous coronary intervention. However, pericardial tamponade following coronary artery perforation may be lethal, and prompt treatment is crucial in managing such patients. Balloon occlusion and the reversal of anticoagulant activity are the common methods used to prevent cardiac tamponade by reducing the amount of bleeding. Herein, we discuss the pros and cons of currently used occlusion types for coronary perforation. Optimal balloon occlusion methods should reduce the amount of bleeding and ameliorate subsequent myocardial ischemia injury, even during cardiac surgery.

  3. Fibular free flap with arteria peronea magna: the role of preoperative balloon occlusion.

    Science.gov (United States)

    Rahmel, Benjamin B; Snow, Thomas M; Batstone, Martin D

    2011-03-01

    The free fibular osteocutaneous flap is a commonly used donor for reconstruction of mandibular defects. Vascular abnormalities and leg trauma are relative contraindications to the use of a fibular free flap. Peroneal arteria magna (PAM) is one such vascular abnormality that may preclude the use of the graft due to the high risk of lower-limb ischemia. Lower-limb angiography is the standard for assessing the lower-limb vascular anatomy; however, the indications remain controversial. Although balloon occlusion has been used to assess the vascular supply in distal bypass surgery, there have no reported cases of balloon occlusion to assess the viability of the distal extremity with PAM. Intraoperative assessment of vascular anatomy with an aborted harvest can lead to significant morbidity and cost. Balloon occlusion provides a relatively safe and minimally invasive technique for assessment of potential lower-limb ischemia in patients with PAM.

  4. Assessment of risk of carotid occlusion with balloon Matas testing and dynamic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Tomoaki; Okuno, Takashi; Moriwaki, Hiroshi; Nakai, Ekini; Nishiguchi, Takashi; Hayashi, Seiji; Komai, Norihiko.

    1988-02-01

    Temporary occlusion of the internal carotid artery with a balloon catheter (balloon Matas test) and simultaneous dynamic computed tomographic scanning (DCT) were performed in four patients with intracranial aneurysms to determine their tolerance for permanent carotid occlusion. Five DCT parameters were evaluated: appearance time, peak time, peak height fitting, first effective moment, and transit time. The patients were characterized into three types: type I (2 patients) - lack of neurological deficit during the balloon Matas test and equally preserved cerebral blood flow (CBF) in the two hemispheres on DCT during carotid occlusion, type II (one patient) - a decreased CBF on the occluded side on DCT despite the lack of neurological deficit; type III (one patient) - neurological signs, such as disturbance of consciousness, aphasia, and right hemiparesis occuring immediately after the start of the balloon Matas test, and a decreased CBF in the region of the middle and anterior cerebral arteries on the occluded side. In the type III patient, occlusion of the internal carotid artery is contraindicated unless an EC-IC bypass procedure that can rapidly provide a large supply of blood is performed. It can be concluded that the balloon Matas/DCT method offers a reliable means of predicting the risk of carotid ligation. (Namekawa, K.).

  5. Computational evaluation of aortic occlusion and the proposal of a novel, improved occluder: Constrained endo-aortic balloon occlusion.

    Science.gov (United States)

    de Vaal, M H; Gee, M W; Stock, U A; Wall, W A

    2016-12-01

    Because aortic occlusion is arguably one of the most dangerous aortic manipulation maneuvers during cardiac surgery in terms of perioperative ischemic neurological injury, the purpose of this investigation is to assess the structural mechanical impact resulting from the use of existing and newly proposed occluders. Existing (clinically used) occluders considered include different cross-clamps (CCs) and endo-aortic balloon occlusion (EABO). A novel occluder is also introduced, namely, constrained EABO (CEABO), which consists of applying a constrainer externally around the aorta when performing EABO. Computational solid mechanics are employed to investigate each occluder according to a comprehensive list of functional requirements. The potential of a state of occlusion is also considered for the first time. Three different constrainer designs are evaluated for CEABO. Although the CCs were responsible for the highest strains, largest deformation, and most inefficient increase of the occlusion potential, it remains the most stable, simplest, and cheapest occluder. The different CC hinge geometries resulted in poorer performance of CC used for minimally invasive procedures than conventional ones. CEABO with a profiled constrainer successfully addresses the EABO shortcomings of safety, stability, and positioning accuracy, while maintaining its complexities of operation (disadvantage) and yielding additional functionalities (advantage). Moreover, CEABO is able to achieve the previously unattainable potential to provide a clinically determinable state of occlusion. CEABO offers an attractive alternative to the shortcomings of existing occluders, with its design rooted in achieving the highest patient safety. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Management of life-threatening celiac-hepatic arterial hemorrhage after pancreaticoduodenectomy: usefulness of temporary balloon occlusion

    Institute of Scientific and Technical Information of China (English)

    WANG Mao-qiang; GUO Li-ping; LIN Han-ying; DUAN Feng; LIU Feng-yong; WANG Zhi-jun

    2011-01-01

    When a large visceral artery is ruptured,uncontrolled bleeding may lead to hemodynamic collapse.Use of endovascular occlusion balloon catheter may provide rapid control of hemorrhage and facilitate definitive therapy.We reported two patients with massive hemorrhage from ruptured celiac-hepatic artery after pancreaticoduodenectomy,who were initially treated percutaneously by temporary selective balloon occlusion.They became critically hemodynamic unstable during the angiographic procedure.Through an 8Fr sheath,a 6Fr compliant latex occlusion balloon was placed proximal to the celiac trunk and inflated,and upon patient stabilization surgical revision and stent-graft placement were successfully performed in the two patients,respectively.Temporary selective balloon occlusion provides fast and effective bleeding control for patient with critically uncontrollable visceral arterial hemorrhage,permitting subsequent use of conventional techniques for management of the arterial bleeding source.

  7. Temporary balloon occlusion of internal carotid artery : a simple and reliable clinical test.

    Directory of Open Access Journals (Sweden)

    Sudhakar K

    2000-04-01

    Full Text Available Balloon test occlusion of internal carotid artery has been frequently used in preoperative evaluation of patients with carotid aneurysms, fistulas and skull based neoplasms in whom arterial sacrifice is planned or considered as a possible part of therapy. We present our experience of the test in 28 patients. The test was positive in four and negative in twenty four patients. The results are compared with cross-compression angiography and the outcome following internal carotid artery sacrifice. There were no complications related to the test and the results accurately predicted the tolerance to occlusion of artery. We found the test safe, simple to perform and reliable to preoperatively detect patients at risk of ischaemic stroke following surgical ligation or endovascular occlusion of internal carotid artery.

  8. Prophylactic balloon occlusion of internal iliac arteries in women with placenta accreta: Literature review and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dilauro, M.D.; Dason, S. [McMaster University, Michael G. DeGroote School of Medicine (Canada); Athreya, S., E-mail: sathreya@stjoes.ca [Diagnostic Imaging, St Joseph' s Healthcare Hamilton, Ontario (Canada)

    2012-06-15

    Aim: To review the literature on the use of prophylactic balloon occlusion alone and in conjunction with arterial embolization of the internal iliac arteries in women with placenta accreta. Materials and methods: The PubMed, MEDLINE, CINAHL, EMBASE, and Cochrane Library databases were searched for keywords related to this technique and its use in the avoidance of caesarean hysterectomy. The relevant published articles were selected and then searched for further references. Results: The literature search found 15 case reports and five studies for a total of 20 articles. The use of balloon catheters to prevent post-partum haemorrhage in women with placenta accreta is controversial with some investigators reporting reduced blood loss and transfusion requirements while others reporting no benefit. This procedure does not appear to reduce operative time or hospital stay. Some groups have described catheter-related complications, such as maternal thromboembolic events and the need for stent placement and/or arterial bypass. Thus far, there is no reported maternal or foetal mortality related to this procedure. Conclusion: Current evidence is based upon case reports and small retrospective studies. Larger studies or randomized controlled trials are essential in order to demonstrate the safety and efficacy of bilateral iliac balloon occlusion. The creation of a data registry would also facilitate the reporting of this technique.

  9. Stingray balloon used in slender percutaneous coronary intervention for chronic total occlusion.

    Science.gov (United States)

    Wu, Eugene B; Ikari, Yuji

    2013-07-01

    Slender chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using 5 Fr radial Ikari catheter is possible in simple CTO cases. We report a case where we initially thought the LAD CTO was short and easy, but we found that the CTO had a considerable amount of calcium and also some tortuosity, making simple wire crossing impossible. We used a Stingray balloon to perform re-entry by tracking the balloon over an Ultimate Bros 3 gram wire using an extension wire. We successfully punctured into true lumen and completed stenting through a slender 5 Fr system. This case demonstrates the beauty of combining the advances in CTO PCI from the East and the West together and also demonstrates the possibility of using the Stingray system in a 5 Fr guiding catheter.

  10. [Perioperative management of abdominal aortic balloon occlusion in patients complicated with placenta percteta: a case report].

    Science.gov (United States)

    Zeng, Hong; Wang, Yan; Wang, Yang; Guo, Xiang-yang

    2015-12-18

    When placenta previa complicated with placenta percreta, the exposure of operative field is difficult and the routine methods are difficult to effectively control the bleeding, even causing life-threatening results. A 31-year-old woman, who had been diagnosed with a complete type of placenta previa and placenta percreta with bladder invasion at 34 weeks gestation. Her ultrasound results showed a complete type of placenta previa and there was a loss of the decidual interface between the placenta and the myometrium on the lower part of the uterus, suggestive of placenta increta. For further evaluation of the placenta, pelvis magnetic resonance imaging was performed, which revealed findings suspicious of a placenta percreta. She underwent elective cecarean section at 36 weeks of gestation. Firstly, two ureteral stents were placed into the bilateral ureter through the cystoscope. After the infrarenal abdominal aorta catheter was inserted via the femoral artery (9 F sheath ), subarachnoid anesthesia had been established. A healthy 2 510 g infant was delivered, with Apgar scores of 10 at 1 min and 10 at 5 min. Immediately after the baby was delivered, following which there was massive haemorrhage and general anaesthesia was induced. The balloon catheter was immediately inflated until the wave of dorsal artery disappeared. With the placenta retained within the uterus, a total hysterectomy was performed. The occluding time was 30 min. The intraoperative blood loss was 2 500 mL. The occluding balloon was deflated at the end of the operation. The patient had stable vital signs and normal laboratory findings during the recovery period and the hemoglobin was 116 g/L. She was discharged six days after delivery without intervention-related complications. This case illustrates that temporary occlusion of the infrarenal abdominal aorta using balloon might be a safe and effective treatment option for patients with placenta previa complicated with placenta percreta, who were at high

  11. A Case Report: Balloon Occlusion Of Vertebral Artery In A Giant Vertebral Artery Aneurysm

    Directory of Open Access Journals (Sweden)

    K. Edraki

    2005-08-01

    Full Text Available Introduction & Background: True aneurysms of extra cranial vertebral arteries are rare. The usual pathogenesis of aneurysms in this location is either penetrating or blunt trauma with resultant pseudo- aneurysm formation. We report a patient with a presumed pseudo-aneurysm of the extra- cranial vertebral artery presenting with painful neck mass, without obvious history of trauma. Case description: A 59-year old man presented with painful left lateral neck mass from 3 month ago with a bruit over it on physical examination. Patient had a history of long term anticoagulant therapy because of chronic lower extremity DVT. Patient was referred to our DSA (Department for angiography. After color Doppler US, CT scan and MR-angiography were performed and a giant aneurysm in left vertebral artery was detected. The lesion was successfully treated by an endovascular technique of balloon occlusion of the verte-bral artery.

  12. Successful Reversal of Chronic Incapacitating Post-TIPS Encephalopathy by Balloon Occlusion of the Stent

    Directory of Open Access Journals (Sweden)

    Daphna Fenyves

    1994-01-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS placement is a new technique allowing decompression of the portal system without the need for abdominal surgery or general anesthetic. This promising procedure appears safe, and is being evaluated in the context of life threatening uncontrollable variceal hemorrhage as well as ascites refractory to medical treatment. Following TIPS, portal flow diversion is associated with hepatic encephalopathy in up to 25% of patients. This is most often mild and treatable but may become uncontrollable, incapacitating and even life threatening in up to 3 to 5% of cases. The authors present two patients in whom such life threatening encephalopathy and stupor was reversed by transjugular balloon occlusion of the TIPS.

  13. Ruptured high flow gastric varices with an intratumoral arterioportal shunt treated with balloon-occluded retrograde transvenous obliteration during temporary balloon occlusion of a hepatic artery

    Institute of Scientific and Technical Information of China (English)

    Motoki Nakai; Morio Sato; Hirohiko Tanihata; Tetsuo Sonomura; Shinya Sahara; Nobuyuki Kawai; Masashi Kimura; Masaki Terada

    2006-01-01

    A patient presented with hematemesis due to gastric variceal bleeding with an intratumoral arterioportal shunt. Contrast-enhanced CT revealed gastric varices and hepatocellular carcinoma with tumor thrombi in the right portal vein. Angiography and angio-CT revealed a marked intratumoral arterioportal shunt accompanied with reflux into the main portal vein and gastric varices. Balloon-occluded retrograde venography from the gastro-renal shunt showed no visualization of gastric varices due to rapid blood flow through the intratumoral arterioportal shunt. The hepatic artery was temporarily occluded with a balloon catheter to reduce the blood flow through the arterioportal shunt, and then concurrent balloon-occluded retrograde transvenous obliteration (BRTO) was achieved. Vital signs stabilized immediately thereafter, and contrast-enhanced CT revealed thrombosed gastric varices. Worsening of hepatic function was not recognized. BRTO combined with temporary occlusion of the hepatic artery is a feasible interventional procedure for ruptured high flow gastric varices with an intratumoral arterioportal shunt.

  14. [Balloon occlusion test of the internal carotid artery for evaluating resectability of blood vessel infiltrating cervical metastasis of advanced head and neck cancers--Heidelberg experience].

    Science.gov (United States)

    Dietz, A; von Kummer, R; Adams, H P; Kneip, M; Galito, P; Maier, H

    1993-11-01

    During the last two years 17 patients of the ENT-Department of the University of Heidelberg suffering from squamous-cell carcinomas of the head and neck underwent a balloon occlusion test of the internal carotid artery (ICA). The investigation was performed because of tumorous infiltration of the large cervical vessels. The balloon occlusion of the ICA was accomplished at the Department of Neuroradiology of the University of Heidelberg. While stopping bloodflow in the ICA of one side for 15-20 min, clinical, electrophysiological and Doppler sonographic monitoring was performed, to detect severe cerebral complications. The specific electrophysiological monitoring contained the detection of MSSEP's (median nerve stimulated somatosensorial evoked potentials) and TCMEP's (transcortical motor evoked potentials) during test occlusion. Balloon occlusion was not possible in three patients because of severe arteriosclerosis. Test occlusion had to be discontinued in three patients because of clinical complications (temporary amaurosis, orthostatic complications). Finally, seven patients showed contraindications during test occlusion for permanent occlusion of the ICA. Four patients had a permanent occlusion of the ICA after tumour resection. In two patients the ICA was removed without problems in test occlusion. The third patient underwent a permanent carotid occlusion because of bleeding complications (in spite of poor clinical tolerance of the test occlusion). In the fourth patient, only intraoperative neuromonitoring with MSSEP's was conducted before permanent carotid occlusion. All four patients did not show any neurological deficits after resection of the ICA. Neurophysiological monitoring played an important role in predicting cerebral complications after permanent occlusion of the ICA.

  15. Balloon occlusion retrograde transvenous obliteration of gastric varices in two-cirrhotic patients with portal vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Borhei, Peyman; Kim, Seung Kwon; Zukerman, Darryl A [Interventional Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis (United States)

    2014-02-15

    This report describes two non-cirrhotic patients with portal vein thrombosis who underwent successful balloon occlusion retrograde transvenous obliteration (BRTO) of gastric varices with a satisfactory response and no complications. One patient was a 35-year-old female with a history of Crohn's disease, status post-total abdominal colectomy, and portal vein and mesenteric vein thrombosis. The other patient was a 51-year-old female with necrotizing pancreatitis, portal vein thrombosis, and gastric varices. The BRTO procedure was a useful treatment for gastric varices in non-cirrhotic patients with portal vein thrombosis in the presence of a gastrorenal shunt.

  16. Isolated Gastric Varices and Use of Balloon-occlusive Retrograde Transvenous Obliteration: A Case Report and Literature Review.

    Science.gov (United States)

    McCarty, Thomas R; Bakhit, Mena; Rustagi, Tarun

    2016-03-01

    Isolated gastric varices are far less prevalent in Western countries where the rate of splenic thrombosis is much lower. However, in Asian countries the entity is more common and therefore a more robust treatment approach has been developed. Balloon-occlusive retrograde transvenous obliteration (BRTO) was first described in 1984 and then revived in 1996. The procedure, while uncommon in the U.S. and not recognized by the AASLD practice guidelines, allows for direct exclusion from the portosystemic system. Here we describe the case of a patient with alcoholic cirrhosis decompensated by bleeding gastric varices treated with BRTO.

  17. The Impact of Aortic Occlusion Balloon on Mortality After Endovascular Repair of Ruptured Abdominal Aortic Aneurysms: A Meta-analysis and Meta-regression Analysis

    NARCIS (Netherlands)

    Karkos, C.; Papadimitriou, C.; Chatzivasileiadis, T.; Kapsali, N.; Kalogirou, T.; Giagtzidis, I.; Papazoglou, K.

    2015-01-01

    INTRODUCTION:We aimed to investigate whether the use of aortic occlusion balloon (AOB) has an impact on mortality of patients undergoing endovascular repair of ruptured abdominal aortic aneurysms (RAAAs).METHODS:A meta-analysis of the English-language literature was undertaken through February 2013.

  18. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, Dale, E-mail: dale_murdoch@health.qld.gov.au [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia); McAulay, Laura [The Prince Charles Hospital, Brisbane (Australia); Walters, Darren L. [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia)

    2014-11-15

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy.

  19. Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

    Energy Technology Data Exchange (ETDEWEB)

    Hörer, Tal M., E-mail: tal.horer@orebroll.se [Örebro University, Department of Cardiothoracic and Vascular Surgery, Örebro University Hospital (Sweden); Hebron, Dan [Hillel Yaffe Medical Center, Department of Radiology (Israel); Swaid, Forat [Bnai-Zion Medical Center, Department of General Surgery (Israel); Korin, Alexander [Hillel Yaffe Medical Center, Trauma Unit (Israel); Galili, Offer [Hillel Yaffe Medical Center, Department of Vascular Surgery (Israel); Alfici, Ricardo [Hillel Yaffe Medical Center, Surgical Division (Israel); Kessel, Boris [Hillel Yaffe Medical Center, Trauma Unit (Israel)

    2016-02-15

    PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach.

  20. Balloon Angioplasty and Drug Eluting Stenting for Treatment of Peripheral Arterial Occlusive Disease

    Directory of Open Access Journals (Sweden)

    Akın İzgi

    2010-08-01

    Full Text Available Peripheral arterial disease is one of the manifestations of systemic atherosclerosis. In the last decade, remarkable technological advances, especially in the stent area, have shifted revascularization strategies from traditional open surgical approaches toward less morbide percutaneous endovascular treatments. However, even with new designed nitinol bare stents, restenosis remains as the major obstacle of this procedures. More recently, drug eluting stent platforms have been used to treat atherosclerotic peripheral arterial disease. In this article, we reviewed new studies relevant to drug eluting stents for lower extremity peripheral arterial occlusive disease.

  1. Evaluation of the fetal dose during prophylactic placement of internal iliac artery balloon occlusion catheters in placenta accreta

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sik [Dept. of Radiology, Gachon University Gil hospital, Incheon (Korea, Republic of); Ahn, Sung Min [Dept. of Radiological Science, Gachon University, Incheon (Korea, Republic of)

    2016-09-15

    Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38∼8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49∼18.27 mGy.

  2. Local drug-delivery balloon for proliferative occlusive in-stent restenosis after drug-eluting stent

    Institute of Scientific and Technical Information of China (English)

    Gianluca Rigatelli; Paolo Cardaioli; Fabio Dell'Avvocata; Massimo Giordan

    2011-01-01

    Drug-coated balloon has been developed as an alternative to drug-eluting stents for in-stent restenosis but the performance of drug infusion balloon in such setting has not been previously described. We present a case of particularly aggressive in-stent restenosis after drug eluting stent implantation treated with a new kind of drug infusion balloon developed in order to overcome the impossibility to inflate regular drug-coated balloon for several dilatation.

  3. Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method

    Directory of Open Access Journals (Sweden)

    Bahareh Eslami

    2010-05-01

    Full Text Available Background: Transcatheter closure of atrial septal defect secundum (ASD-II has become an alternative method for surgery. We sought to compare the two-dimensional transesophageal echocardiography (TEE method for measuring atrial septal defect with balloon occlusive diameter (BOD in transcatheter ASD-II closure.Methods: A total of 39 patients (71.1% female, mean age: 35.31 ± 15.37 years who underwent successful transcatheter closure of ASD-II between November 2005 and July 2008 were enrolled in this study. Transthoracic echocardiography (TTE and TEE were performed to select suitable cases for device closure and measure the defect size before the procedure, and BOD measurement was performed during catheterization via TEE. The final size of the selected device was usually either equal to or 1 – 2 mm larger than the BOD of the defect.Results: The mean defect size obtained by TEE and BOD was 18.50 ± 5.08 mm and 22.86 ± 4.76 mm, respectively. The mean difference between the values of ASD size obtained by TEE and BOD was 4.36 ± 2.93 mm. In comparison with BOD, TEE underestimated the defect size in 94.9%, but TEE value being equal to BOD was observed in 5.1%. There was a good linear correlation between the two measurements: BOD = 0.773 × ASD size by TEE+8.562; r2 = 67.9.1%. A negative correlation was found between TEE sizing and the difference between BOD and TEE values (r = -0.394, p value = 0.013.Conclusion: In this study, BOD was larger than ASD size obtained by two-dimensional TEE. However, TEE maximal defect sizing correlates with BOD and may provide credible information in device size selection for transcatheter ASD closure.

  4. Effectiveness of CO2-insufflated endoscopic submucosal dissection with the duodenal balloon occlusion method for early esophageal or gastric cancer: a randomized case control prospective study

    Directory of Open Access Journals (Sweden)

    Mori Hirohito

    2012-04-01

    Full Text Available Abstract Background Endoscopic submucosal dissection (ESD has typically been performed using air insufflation. Recently, however, insufflation of CO2 has been increasingly used to avoid complications. This prospective study was designed to compare the CO2 concentration, intestinal volume, and acid–base balance using the duodenal balloon procedure. Methods From June 2010 to February 2011, we enrolled 44 patients with esophageal or gastric cancer and randomly allocated them into two groups. We compared 22 patients undergoing CO2-insufflated ESD with a balloon placed into the duodenal bulb (duodenal balloon group and 22 patients undergoing regular CO2-insufflated ESD (regular group. Three-dimensional computed tomography was performed before and after the procedure to measure intestinal volume. CO2 concentrations were measured every 10 minutes. The visual analogue system (VAS scores for postoperative symptoms were recorded, and pH was measured immediately after the procedure. This was a prospective case control study randomized by the sealed envelope method. Results Intestinal CO2 gas volume before and after ESD was lower in the duodenal balloon group than in the regular group (P = 0.00027. The end-tidal CO2 level was significantly lower in the duodenal balloon group than in the regular group (P = 0.0001. No significant differences in blood ΔpH were found between the two groups. The VAS score for the occurrence of nausea due to abdominal distension after ESD indicated a significant difference (P = 0.031. Conclusions ESD using the duodenal balloon occlusion method is effective for reduction of post-ESD intestinal CO2 gas volume, resulting in a lower total amount of CO2 insufflation during ESD and reducing harmful influences on the human body to some extent.

  5. Haemodynamic changes in the liver under balloon occlusion of a portal vein branch-evaluation with single-level dynamic computed tomography during hepatic arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Komada, Y. [Department of Radiology/Center for Advanced Medical Technology, Sendagi, Bunkyo-ku, Tokyo (Japan)]. E-mail: brian-komada@msj.biglobe.ne.jp; Murata, S. [Department of Radiology/Center for Advanced Medical Technology, Sendagi, Bunkyo-ku, Tokyo (Japan); Tajima, H. [Department of Radiology/Center for Advanced Medical Technology, Sendagi, Bunkyo-ku, Tokyo (Japan); Kumita, S. [Department of Radiology/Center for Advanced Medical Technology, Sendagi, Bunkyo-ku, Tokyo (Japan); Kanazawa, H. [3rd Department of Internal Medicine, Sendagi, Bunkyo-ku, Tokyo (Japan); Tajiri, T. [1st Department of Surgery, Nippon Medical School, Sendagi, Bunkyo-ku, Tokyo (Japan)

    2007-06-15

    Aim: To assess haemodynamic changes in the liver under temporary occlusion of an intrahepatic portal vein. Materials and methods: Between February 2000 and October 2004, 16 patients with hepatobiliary disease underwent single-level dynamic computed tomography during hepatic arteriography (SLD-CTHA) under temporary balloon occlusion of an intrahepatic portal vein. All patients needed percutaneous transhepatic portography for therapy of their disease. SLD-CTHA was undertaken to clarify the time-attenuation curve influenced by portal vein occlusion, and it was performed continuously over a period of 30 s. The difference in absolute attenuation of the liver parenchyma in segments with occluded and non-occluded portal vein branches was determined by means of the CT number, and the difference in absolute attenuation of the occluded and non-occluded portal veins themselves was also evaluated. Results: SLD-CTHA demonstrated a demarcated hyperattenuation area in the corresponding distribution of the occluded portal vein branch. The attenuation of the liver parenchyma supplied by the occluded portal vein was significantly higher than that in the non-occluded area (p < 0.01). The balloon-occluded portal branch enhancement in 15 of 16 cases (94%) appears due to arterio-portal communications. Failure to evaluate a remaining case for portal branch enhancement was due to absence of a visualized portal branch in the section. Conclusion: Under temporary occlusion of an intrahepatic portal vein, hepatic angiography produced enhancement of the occluded portal branches and their corresponding parenchymal distribution; this finding is considered consistent with the presence of arterio-portal communications.

  6. The removal of intravascular bullets by interventional radiology: the prevention of central migration by balloon occlusion--case report.

    Science.gov (United States)

    Sclafani, S J; Shatzkes, D; Scalea, T

    1991-10-01

    A migratory intravascular bullet fragment located within the hypogastric vein was removed successfully with the aid of interventional radiologic techniques. The authors describe the use of the technique of balloon trapping as part of this procedure. A balloon should be inflated between the foreign body and the heart before retrieval is attempted in order to prevent migration back to the heart during the manipulation.

  7. Acute embolic occlusion of the right common iliac artery after revision total hip arthroplasty treated with catheter-directed thrombolysis and balloon angioplasty: A case report

    Directory of Open Access Journals (Sweden)

    Hongqi Yang

    2015-07-01

    Full Text Available Methods: A 63-year-old woman with atrial fibrillation presented clinical symptoms and signs of acute ischemia in the right lower extremity on the 17th postoperative day after revision total hip arthroplasty of the left hip for aseptic loosening of femoral component. Aspirin was discontinued 7 days before surgery. Both computed tomography angiography and digital subtraction angiography demonstrated complete occlusion of the right common iliac artery. An emergency catheter-directed thrombolysis with urokinase combined with balloon angioplasty was performed to obtain complete patency of the right common iliac artery. Results: The patient received anticoagulation and antiplatelet therapy postoperatively and was fine at the 2-year follow-up. Conclusions: This case demonstrated that catheter-directed thrombolysis combined with balloon angioplasty could be an efficacious, minimally invasive approach for the treatment of acute embolic occlusion of the common iliac artery. Preoperative anticoagulation for patients undergoing total hip arthroplasty with long-term use of aspirin for atrial fibrillation needs further investigation.

  8. Temporary balloon occlusion as therapy for uncontrollable arterial hemorrhage in multiply injured patients; Temporaere Ballonokklusion als Therapie unkontrollierbarer arterieller Blutungen bei Polytraumapatienten

    Energy Technology Data Exchange (ETDEWEB)

    Rieger, J.; Linsenmaier, U.; Rock, C.; Pfeifer, K.J. [Abt. fuer Radiologie, Klinikum Innenstadt, Ludwig-Maximilian-Univ., Muenchen (Germany); Euler, E. [Chirurgische Klinik und Poliklinik, Klinikum Innenstadt, Ludwig-Maximilian-Univ., Muenchen (Germany)

    1999-01-01

    Purpose: Presentation of temporary balloon occlusion as an interventional radiological method for managing hemorrhage in multiply injured patients with uncontrollable loss of blood. Method: Temporary, non-selective arterial occlusion by introduction of a balloon catheter contralaterally to the source of bleeding has been performed since 1992 on 7 patients with multiple injuries, hemorrhagic shock requiring reanimation, and angiographic demonstration of an arterial hemorrhage in the supply region of the internal iliac artery with complex pelvic fracture. In each case a PTA balloon catheter was introduced transfemorally, non-selectively positioned proximal to the bleeding source, and left in place for 24-48 h under manometric control. Control angiographies were performed prior to catheter removal. Results: The bleeding was stopped immediately in all 7 patients. The hemodynamic stability made transport and thus further surgical management and/or a short-term treatment in the intensive-care station possible. Control angiographies confirmed that the bleeding had stopped in all patients. Conclusions: We recommend temporary balloon occlusion as a rapid and effective method for the management of bleeding in otherwise uncontrollable traumatic hemorrhages in the supply region of the internal iliac artery. (orig.) [Deutsch] Ziel: Vorstellung der temporaeren Ballonokklusion als interventionell-radiologischer Methode zur Blutungskontrolle bei Polytraumapatienten mit unkontrollierbarem Blutverlust. Methode: Temporaerer, nicht-selektiver arterieller Gefaessverschluss mit kontralateral der Blutungsquellen eingefuehrten PTA-Ballonkathetern bei seit 1992 insgesamt 7 Patienten mit Polytrauma, reanimationspflichtigem haemorrhagischem Schock und angiographischem Nachweis einer arteriellen Blutung im Versorgungsgebiet der A. iliaca interna im Rahmen einer komplexen Beckenfraktur. Transfemoral wurde jeweils ein PTA-Ballonkatheter eingefuehrt, nicht selektiv proximal der Blutungsquelle

  9. The role of resuscitative endovascular balloon occlusion of the aorta (REBOA) as an adjunct to ACLS in non-traumatic cardiac arrest: A review of key concepts, physiology, current evidence, and future directions.

    Science.gov (United States)

    Daley, James; Morrison, Jonathan James; Sather, John; Hile, Lisa

    2017-01-12

    Non-traumatic cardiac arrest is a major public health problem that carries an extremely high mortality rate. If we hope to increase the survivability of this condition, it is imperative that alternative methods of treatment are given due consideration. Balloon occlusion of the aorta can be used as a method of circulatory support in the critically ill patient. Intra-aortic balloon pumps have been used to temporize patients in cardiogenic shock for decades. More recently, resuscitative endovascular balloon occlusion of the aorta (REBOA) has been utilized in the patient in hemorrhagic shock or cardiac arrest secondary to trauma. Aortic occlusion in non-traumatic cardiac arrest has the effect of reducing the vascular volume that the generated cardiac output is distributed across. This augments myocardial and cerebral perfusion, increasing the probability of a return to a good quality of life for the patient. This phenomenon has been the subject of numerous animal studies dating back to the early 1980s; however, the human evidence is limited to several small case series. Animal research has demonstrated improvements in cerebral and coronary perfusion pressure during ACLS that lead to statistically significant differences in mortality. Several case series in humans have replicated these findings, suggesting the efficacy of this procedure. The objectives of this review are to: 1) introduce the reader to REBOA 2) review the physiology of NTCA and examine the current limitations of traditional ACLS 3) summarize the literature regarding the efficacy and feasibility of aortic balloon occlusion to support traditional ACLS.

  10. “REBOA” – Is it Really Safe? A Case with Massive Intracranial Hemorrhage Possibly due to Endovascular Balloon Occlusion of the Aorta (REBOA)

    Science.gov (United States)

    Uchino, Hayaki; Tamura, Nobuichiro; Echigoya, Ryosuke; Ikegami, Tetsunori; Fukuoka, Toshio

    2016-01-01

    Patient: Female, 86 Final Diagnosis: Polytrauma Symptoms: Shock Medication: — Clinical Procedure: Resuscitative endovascular balloon occlusion of the aorta Specialty: Orthopedics and Traumatology Objective: Unusual or unexpected effect of treatment Background: Non-compressible torso hemorrhage continues to be the leading cause of preventable death in trauma patients. Recent case series report that resuscitative endovascular balloon occlusion of the aorta (REBOA) in the trauma population is a technically feasible method to manage the patients with exsanguinating hemorrhage. On the other hand, it seems that REBOA is being widely promoted prematurely. Complications due to REBOA haven’t been reported much in the literature, and they could have been underestimated. Case Report: An 86-year-old female presented to our emergency department following a pedestrian-vehicle accident. On admission, she was hemodynamically unstable with systolic blood pressure (SBP) of 78 mm Hg. She responded to fluid administration, and computed tomography (CT) scan showed cerebral contusion, subarachnoid hemorrhage, pelvic fracture with contrast extravasation, and thoracic spine fracture. Her condition deteriorated after the CT scan, and she became hemodynamically unstable. REBOA was inserted and inflated. Her blood pressure recovered and even became as high as SBP of 180 mm Hg. Transarterial embolization for pelvic fracture was successfully performed. A subsequent head CT scan showed massive intracranial hemorrhage with penetration to the ventricle, which was fatal. She died on the same day due to cerebral herniation. Conclusions: REBOA is now considered as an alternative to resuscitative thoracotomy or even widely indicated to control hemorrhage. We should be more cautious about using REBOA for polytrauma patients since it could make hemorrhage worse. Further research, assessing its potential complications and safety, will be required to elucidate clear indications for REBOA in trauma

  11. Closing the gap between coil and balloon in the neurointerventional armamentarium? Initial clinical experience with a nitinol vascular occlusion plug

    Energy Technology Data Exchange (ETDEWEB)

    Gralla, Jan; Schroth, Gerhard; El-Koussy, Marwan; Brekenfeld, Caspar [University of Bern, Department of Diagnostic and Interventional Neuroradiology, Inselspital, Bern (Switzerland); Kickuth, Ralph [Interventional and Pediatric Radiology, Department of Diagnostic, Bern (Switzerland); Do, Dai-Do [University of Bern, Department of Angiology, Inselspital, Bern (Switzerland)

    2008-08-15

    The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions. (orig.)

  12. A Novel Fluoroscopy-free, Resuscitative Endovascular Aortic Balloon Occlusion System in a Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-07-01

    0.755 Female 8 ( 100 %) 8 ( 100 %) n/a Physiologic SBP , mm Hg 94 (37) 81 (10) 0.180 MAP, mm Hg 65.1 (10.4) 64.3 (6.4) 0.895 HR, beats/min 81 (8) 93 (13...CBS and PBS groups (35 [8] vs. 34 [5]; p = 0.89). Accurate balloon positioning and inflation occurred in 100 % of the CBS and 88% of the PBS group...main body was 100 cm, consisting of a semistiff 0.035-inch core wire extending 20 cm beyond the trail end of the device. The lead or insertion end

  13. Management of post-surgical biliary leakage with percutaneous transhepatic biliary drainage (PTBD) and occlusion balloon (OB) in patients without dilatation of the biliary tree: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Pedicini, Vittorio; Poretti, Dario; Brambilla, Giorgio [Humanitas Clinical Institute, Department of Diagnostic Imaging, Rozzano, Milan (Italy); Mauri, Giovanni; Trimboli, Manuela [Humanitas Clinical Institute, Department of Diagnostic Imaging, Rozzano, Milan (Italy); University of Milan School of Medicine, Unit of Radiology, Ospedale San Paolo, Milan (Italy); Sconfienza, Luca Maria; Sardanelli, Francesco [University of Milan School of Medicine, Unit of Radiology, IRCCS Policlinico San Donato, Department of Medical and Surgical Sciences, Milan (Italy); Cornalba, Gianpaolo [University of Milan School of Medicine, Unit of Radiology, Ospedale San Paolo, Milan (Italy)

    2010-05-15

    To compare the outcome of patients affected by biliary leak after major biliary surgery and treated with percutaneous transhepatic biliary drainage (PTBD) alone with that of similar patients treated with PTBD and concurrent positioning of an occlusion balloon (PTBD-OB). We retrospectively reviewed the results of the use of PTBD or PTBD-OB performed at our institution from 2004 to 2008 in patients with post-surgical biliary leak. Sixteen patients entered the evaluation. PTDB alone was performed in 9 men (age 59.7 {+-} 13.4 years [mean {+-} standard deviation]; median 60 years), while PTBD-OB was performed in 7 patients (5 men, 2 women, age 71.3 {+-} 9.3 years; median 68 years). No significant difference between groups was found regarding age (p = 0.064) and sex (p = 0.175) distribution, number of procedures (3.1 {+-} 1.62; 2 vs 1.7 {+-} 1.1; 1, p = 0.151), and days of disease before recovery, death or modification of treatment (51.6 {+-} 66.8; 23 vs 18.6 {+-} 15.1; 14, p = 0.266). The number of patients treated with PTBD-OB who fully recovered (7/7, 100%) was significantly higher than that of patients treated with PTBD alone (4/9, 44%, p = 0.034). This procedure appears to be clinically effective, being associated with a higher probability of recovery in patients treated for post-surgical biliary leak. Further studies are needed to confirm these preliminary results. (orig.)

  14. Pumpkin Balloon

    OpenAIRE

    Nishimura, Jun; 西村, 純

    1992-01-01

    The Pumpkin shaped balloons, which are the extreme case of the heart-type balloons had been studied as one of the promising candidate of the super pressure balloons. Here, detailed studies for the features of the pumpkin balloons are described, particularly by comparing with those of the spherical shaped super pressure balloons.

  15. Femoro-popliteal artery occlusions treated by percutaneous transluminal angioplasty and enclosed thrombolysis

    DEFF Research Database (Denmark)

    Tønnesen, K H; Holstein, P; Andersen, E

    1991-01-01

    Removal of fibrin from the site of a newly dilated femoro-popliteal occlusion may be an attractive way of preventing rethrombosis. A double balloon catheter with a dilating tip balloon and an occlusive balloon 10, 15 or 20 cm approximately were introduced percutaneously. Following successful dila...

  16. Occlusal stability.

    Science.gov (United States)

    Wiens, Jonathan P; Priebe, Jennifer W

    2014-01-01

    Occlusion is the foundation for clinical success in fixed, removable, and implant prosthodontic treatment. Understanding those principles is critical when restoring a patient's occlusion. Many philosophies, devices, and theories of occlusion have evolved based on anecdotal clinical observations and applied geometric perceptions. The literature has reported these classic and contemporary occlusal concepts. As evidence-based dentistry emerged, it championed scrutiny of previously held beliefs, resulting in the abandonment of many pragmatic, yet beneficial occlusal procedures. The impetus toward scientific discovery, whereby factual information might be universally applied in dental education and clinical practice, has renewed interest in occlusal studies.

  17. 穿透型胎盘植入行腹主动脉球囊置入的围术期管理1例%Perioperative management of abdominal aortic balloon occlusion in patients compli-cated with placenta percteta:a case report

    Institute of Scientific and Technical Information of China (English)

    曾鸿; 王妍; 王阳; 郭向阳

    2015-01-01

    SUMMARY When placenta previa complicated with placenta percreta, the exposure of operative field is difficult and the routine methods are difficult to effectively control the bleeding, even causing life-threatening results. A 31-year-old woman, who had been diagnosed with a complete type of placenta pre-via and placenta percreta with bladder invasion at 34 weeks gestation. Her ultrasound results showed a complete type of placenta previa and there was a loss of the decidual interface between the placenta and the myometrium on the lower part of the uterus, suggestive of placenta increta. For further evaluation of the placenta, pelvis magnetic resonance imaging was performed, which revealed findings suspicious of a placenta percreta. She underwent elective cecarean section at 36 weeks of gestation. Firstly, two ureteral stents were placed into the bilateral ureter through the cystoscope. After the infrarenal abdominal aorta catheter was inserted via the femoral artery ( 9 F sheath ) , subarachnoid anesthesia had been estab-lished. A healthy 2 510 g infant was delivered, with Apgar scores of 10 at 1 min and 10 at 5 min. Imme-diately after the baby was delivered, following which there was massive haemorrhage and general anaes-thesia was induced. The balloon catheter was immediately inflated until the wave of dorsal artery disap-peared. With the placenta retained within the uterus, a total hysterectomy was performed. The occluding time was 30 min. The intraoperative blood loss was 2 500 mL. The occluding balloon was deflated at the end of the operation. The patient had stable vital signs and normal laboratory findings during the recovery period and the hemoglobin was 116 g/L. She was discharged six days after delivery without intervention-related complications. This case illustrates that temporary occlusion of the infrarenal abdominal aorta using balloon might be a safe and effective treatment option for patients with placenta previa complicated with placenta percreta

  18. Angioplasty with drug coated balloons for the treatment of infrainguinal peripheral artery disease.

    Science.gov (United States)

    Werner, Martin

    2016-09-01

    Restenosis or re-occlusion after femoropopliteal angioplasty or stent implantation is the main limitation of endovascular treatment strategies for peripheral artery disease. Within the last years, balloon catheters with anti-proliferative drug coating on the balloon surface have shown to be associated with higher patency rates compared to plain balloon angioplasty. Thus, drug-coated balloons were gradually adopted in many interventional centres for the treatment of femoropopliteal obstructions. The current review summarises the existing evidence for drug-coated balloons in the infrainguinal vessels and their indication in special lesion cohorts.

  19. Interventional therapy experience from the nursing of patients with lower limb arteriosclerosis occlusion syndrome

    Directory of Open Access Journals (Sweden)

    Li-wen ZHU

    2014-10-01

    Full Text Available Objective: To explore the nursing methods of lower limb arteriosclerosis occlusion disease with interventional therapy. Methods: Analyze perioperative nursing for 30 cases of lower limb arteriosclerosis occlusion with stenting and balloon dilatation. Results: 27 cases of patients with stent implantation, 3 cases of balloon dilatation, including 3 cases of late stent patients had bypass surgery, the rest has achieved good nursing effect. Conclusion: Perioperative nursing plays an important role in AOS interventional therapy and early recovery of the patient.

  20. Nursing assistance during endovascular reconstruction using balloon occlusion of the abdominal aorta for patients with severe pelvic trauma and vascular injury%严重骨盆外伤合并血管损伤应用腹主动脉球囊阻断技术的护理配合

    Institute of Scientific and Technical Information of China (English)

    钱维明; 杜丽丽; 项海燕

    2011-01-01

    This paper summarizes the experience of nursing assistance during endovascular reconstruction using balloon occlusion of the abdominal aorta for patients with severe pelvic trauma and vascular injury in traffic accidents. Measures of nursing assistance included preoperative preparation,maintaining vascular access,monitoring urine volume,bilateral dorsalis pedis arterial pulses and the change of blood pressure during the operation. Postoperative nursing focused on effective compression on femoral artery after withdrawal of catheter,observation of urine volume,and local hematoma and skin temperature of lower extremities. The four patients got through the perioperative period safely and were discharged with recovery.%总结了4例因车祸致严重骨盆外伤合并血管损伤的急诊患者应用腹主动脉球囊阻断技术的护理配合经验.护理配合重点包括:完善术前准备,术中确保动静脉通路畅通,准确观察尿量,密切观察双侧足背动脉的搏动,监测血压的变化,穿刺侧肢体拔管后予有效压迫,观察尿量、局部血肿及肢体皮温.4例患者均安全度过围手术期,痊愈出院.

  1. Choice PTTM guidewire for recanalization of total occlusive coronary arteries

    Institute of Scientific and Technical Information of China (English)

    OUYANG Ping; HE Shi-hua; CHEN Wei-Kang; WOO Carrie

    2002-01-01

    Objective: To evaluate the therapeutic effects of 0. 014″Choice PTTM wire in chronic total occlusion angioplasty. Methods: Balloon angioplasty was attempted in 25 arteries with chronic total occlusion,with the mean time of occlusion of 17±13 months (ranging from 2 to 84 months) and mean length of 14±6mm (ranging from 5 to 25 mm). The morphology of the lesions included bridging collaterals (4 cases), calcification (3 cases) and major side branch at the lesion (4 cases) . Choice PTTM wire was used electively in all the cases. Results: Lesion was crossed successfully in 92% (23/25) cases, without incidences of dissection of the coronary artery with subintimal entry. Balloon angioplasy and stenting (n=21) were performed with good immediate angiograghic results. Acute myocardial infarction or death occurred in none of the patients.Conclusion Successful recanalization of chronic coronary total occlusions using Choice PTTM wire can be achieved with good safety.

  2. The use of a cutting balloon in contemporary reverse controlled antegrade and retrograde subintimal tracking (reverse CART) technique.

    Science.gov (United States)

    Nakabayashi, Keisuke; Okada, Hisayuki; Oka, Toshiaki

    2016-07-11

    The key concept of reverse controlled antegrade and retrograde tracking (CART) technique is retrograde puncture with a tapered wire to an antegrade balloon (contemporary reverse CART) or new connections between the antegrade and retrograde subintimal space (classical reverse CART). In our case, a 75-year-old man with severe chronic total occlusion of the right coronary artery, reverse CART with conventional balloons could not be accomplished. Externalization wiring was completed by contemporary reverse CART using a cutting balloon as an antegrade balloon to improve the fenestration force of the retrograde guidewire. Thus, the use of a cutting balloon for contemporary reverse CART might be promising.

  3. Occlusion of pulmonary arteriovenous malformations by use of vascular plug

    DEFF Research Database (Denmark)

    Andersen, P E; Kjeldsen, A D

    2007-01-01

    Pulmonary arteriovenous malformations are commonly treated by embolization with coils or balloons to prevent cerebral complications and to raise the oxygenation of the blood. The Amplatzer vascular plug is a new occlusive device made of a self-expanding cylindrical nitinol mesh. It is fast and safe...

  4. Segmentally enclosed thrombolysis in percutaneous transluminal angioplasty for femoropopliteal occlusions

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Nielsen, J D;

    1991-01-01

    Segmentally enclosed thrombolysis (SET) was performed immediately following 34 percutaneous transluminal angioplasties (PTAs) for femoropopliteal occlusions. The dilated segment was sealed off with a double balloon catheter, and recombinant tissue plasminogen activator (rt-PA) 1 mg/ml and heparin...

  5. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  6. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate?

  7. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  8. Lingualized occlusion. An occlusion for all reasons.

    Science.gov (United States)

    Parr, G R; Ivanhoe, J R

    1996-01-01

    This authors make practical recommendations for a wide variety of clinical situations, including various anteroposterior and buccolingual arch discrepancies. Many of the ideals of the anatomical and mechanical schools of thought are blended. In addition to being a valuable clinical adjunct, Lingualized Occlusion also has great application in undergraduate dental education. It is a simpler occlusal scheme to teach and learn.

  9. Acute arterial occlusion - kidney

    Science.gov (United States)

    Acute renal arterial thrombosis; Renal artery embolism; Acute renal artery occlusion; Embolism - renal artery ... kidney can often result in permanent kidney failure. Acute arterial occlusion of the renal artery can occur after injury or trauma to ...

  10. Hydrogel based occlusion systems

    OpenAIRE

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A; Mendes, E.; Neves, H.P.; Herijgers, P; Verbrugghe, Y.; Shacham, Y.; Engel, L.; Krylov, V

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a target occlusion location. The hydrogel is configured to permanently occlude the target occlusion location in the swollen state. The hydrogel may be an electro-activated hydrogel (EAH) which could be ...

  11. Long-term Luminal Renarrowing After Successful Elective Coronary Angioplasty of Total Occlusions : A Quantitative Angiographic Analysis

    NARCIS (Netherlands)

    A.G. Violaris (Andonis); R. Melkert (Rein); P.W.J.C. Serruys (Patrick)

    1995-01-01

    textabstractBackground The long-term angiographic outcome after successful dilatation of coronary occlusions remains unclear. The objective of this study was to examine long-term restenosis after successful balloon dilatation of coronary occlusions at a predetermined time interval with quantitative

  12. Minimally invasive per-catheter occlusion and dilation procedures for congenital cardiovascular abnormalities in dogs.

    Science.gov (United States)

    Tobias, Anthony H; Stauthammer, Christopher D

    2010-07-01

    With ever-increasing sophistication of veterinary cardiology, minimally invasive per-catheter occlusion and dilation procedures for the treatment of various congenital cardiovascular abnormalities in dogs have become not only available, but mainstream. Much new information about minimally invasive per-catheter patent ductus arteriosus occlusion has been published and presented during the past few years. Consequently, patent ductus arteriosus occlusion is the primary focus of this article. Occlusion of other less common congenital cardiac defects is also briefly reviewed. Balloon dilation of pulmonic stenosis, as well as other congenital obstructive cardiovascular abnormalities is discussed in the latter part of the article.

  13. Balloon-assisted guide catheter positioning to overcome extreme cervical carotid tortuosity: technique and case experience

    OpenAIRE

    Peeling, Lissa; Fiorella, David

    2013-01-01

    Background and significance We describe a method by which to efficiently and atraumatically achieve distal positioning of a flexible guiding catheter beyond extreme cervical tortuosity using a hypercompliant temporary occlusion balloon. Methods A retrospective review of a prospective neuroendovascular database was used to identify cases in which a hypercompliant balloon catheter (Hyperform or Hyperglide, ev3/Covidien, Irvine, California, USA; Scepter or Scepter XC, Alisa Viejo, California, US...

  14. Balloon-guided navigation technique to perform stenting in an acutely angled anterior cerebral artery.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Moscovici, Samuel; Itshayek, Eyal

    2012-03-01

    The complex anatomic features of wide-necked anterior communicating artery aneurysms represent an endovascular challenge. Compliant balloons and microstents are frequently required to achieve aneurysm occlusion. When the angle between the A1 and A2 segments is acute, microcatheter navigation is hazardous, and may be difficult or sometimes impossible with standard techniques. We present our technique using a support balloon to facilitate guidewire engagement and navigation of A2, and to assist with microcatheterization in this unfavorable vascular anatomy.

  15. Aortic Balloon Occlusion is Effective in Controlling Pelvic Hemorrhage

    Science.gov (United States)

    2012-05-08

    improvised explosive devices (IEDs) [6]. Frequently these patients have sustained bilateral high lower extremity amputations with pelvic disruption and...inal hemorrhage [16,17]. However, the technique was not recommended for practice because of the high incidence of hind limb paralysis in survived...injury patterns. Another limitation relates to the artificial nature of the induced coagulopathy. Specifically, the model of coagulop- athy in this

  16. The Inflammatory Sequelae of Aortic Balloon Occlusion in Hemorrhagic Shock

    Science.gov (United States)

    2014-04-13

    prophylactically deliver an anti inflammatory perfusate such as a statin suspension [37]. 5. Conclusions The present study reaffirms that in severe...experimental model of ischemia reperfusion in the rat . J Pharmacol Sci 2006;102:413. j o u r n a l o f s u r g i c a l r e s e a r c h 1 9 1 ( 2 0 1 4 ) 4 2 3 4 3 1 431

  17. Occlusion: an orthodontic perspective.

    Science.gov (United States)

    Kasrovi, P M; Meyer, M; Nelson, G D

    2000-10-01

    In recent years, orthodontists have examined their concepts of occlusion. In current literature, at professional meetings, and in continuing education courses, one hears an ongoing discussion of condylar position and mandibular border movements in relation to occlusion. There is a wide variation in opinion as to whether dental occlusion and TMJ function are interdependent. The authors have adopted a dynamic concept of dental function to replace the traditional static view of molar relationship and incisor overlap. This article discusses how occlusion has evolved in orthodontics and reviews Andrews' six keys to ideal static occlusion, the goals of ideal dynamic occlusion, and the six signs of developing malocclusions. The authors also review the literature on the relationship between orthodontics, occlusion, and TMD.

  18. [Occlusion, articulated and articulation].

    Science.gov (United States)

    De Boever, J A

    1990-01-01

    In this paper the so-called 'normal' or 'ideal' occlusal relationships are described in static centric as well as in dynamic, eccentric positions. However, difference is made between the different occlusal concepts. There is no real antagonism between the 'physiologic occlusal concept' in natural dentition and the 'therapeutic occlusal concept' on which the treatment should be based in restoring the occlusion. The different forms of occlusion and articulation found in the natural dentition are the expression of physiologic, biological variations. The rest position of the mandible is an unreliable reference point in occlusal rehabilitation. Moderate attrition in older patients should not be considered as pathologic and there is no indication for treatment in absence of functional pathology.

  19. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  20. Development of a balloon volume sensor for pulsating balloon catheters.

    Science.gov (United States)

    Nolan, Timothy D C; Hattler, Brack G; Federspiel, William J

    2004-01-01

    Helium pulsed balloons are integral components of several cardiovascular devices, including intraaortic balloon pumps (IABP) and a novel intravenous respiratory support catheter. Effective use of these devices clinically requires full inflation and deflation of the balloon, and improper operating conditions that lead to balloon under-inflation can potentially reduce respiratory or cardiac support provided to the patient. The goal of the present study was to extend basic spirographic techniques to develop a system to dynamically measure balloon volumes suitable for use in rapidly pulsating balloon catheters. The dynamic balloon volume sensor system (DBVSS) developed here used hot wire anemometry to measure helium flow in the drive line from console to catheter and integrated the flow to determine the volume delivered in each balloon pulsation. An important component of the DBVSS was an algorithm to automatically detect and adjust flow signals and measured balloon volumes in the presence of gas composition changes that arise from helium leaks occurring in these systems. The DBVSS was capable of measuring balloon volumes within 5-10% of actual balloon volumes over a broad range of operating conditions relevant to IABP and the respiratory support catheter. This includes variations in helium concentration from 70-100%, pulsation frequencies from 120-480 beats per minute, and simulated clinical conditions of reduced balloon filling caused by constricted vessels, increased driveline, or catheter resistance.

  1. Mars Solar Balloon Lander Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  2. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  3. Temporomandibular disorders and occlusion.

    Science.gov (United States)

    Badel, Tomislav; Marotti, Miljenko; Pavicin, Ivana Savić; Basić-Kes, Vanja

    2012-09-01

    Occlusion has an important place within the multifactorial concept of the temporomandibular disorder (TMD) etiopathogenesis as well as in every form of dental treatment. The modern concept of treatment of these disorders differentiates initial and definitive forms of treatment. The aim of this paper is to analyze recent viewpoints on the role of occlusion in the etiopathogenesis and treatment ofTMDs. Masticatory muscles and temporomandibular joints are directly connected with occlusal relations and TMDs are traditionally linked with occlusal disorders. The initial occlusal treatment can be applied to all TMD patients, regardless of their having intact teeth with respect to physiological occlusal relations and in patients in need of orthodontic or prosthodontic treatment or an oral surgical procedure. On managing TMD patients, there are doubts about the indications for definitive treatment and whether there has been a possibility of treating a painful TMD by reversible treatment modalities, that is, by initial treatment. Other types of orofacial pain such as trigeminal neuralgia can be comorbid with TMDs but also result in unnecessary procedures on the teeth and prosthodontic work if they are not recognized. Although dental profession mainly recognizes the importance of occlusal treatment of TMD problems, their relationship is controversial because it is not strictly demonstrated in numerous scientific studies. Occlusion is not the dominant cause of TMD problems.

  4. Hydrogel based occlusion systems

    NARCIS (Netherlands)

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A.; Mendes, E.; Neves, H.P.; Herijgers, P.; Verbrugghe, Y.; Shacham, Y.; Engel, L.; Krylov, V.

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a tar

  5. Occlusion effects, Part II

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    The present report studies the mechanism of the occlusion effect by means of literature studies, experiments and model estimates. A mathematical model of the occlusion effect is developed. The model includes the mechanical properties of the earmould and the airborne sound as well as the body...

  6. Occlusion effects, Part I

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    annoyances and the objective measurements were analysed. Persons suffering from tinnitus behaved differently than person without tinnitus. The latter group showed significant relations between the measured occlusion effect, hearing loss and the personal of occlusion. The actual sensation level is also...

  7. A comparison of pulmonary arterial occlusion algorithms for estimation of pulmonary capillary pressure.

    Science.gov (United States)

    Pellett, A A; Johnson, R W; Morrison, G G; Champagne, M S; deBoisblanc, B P; Levitzky, M G

    1999-07-01

    Using the arterial occlusion method, we compared five literature-based estimates of pulmonary capillary pressure (Ppc) with the corresponding double occlusion pressures (Pdo) in anesthetized dogs whose chests had been closed after sternotomy for instrumentation. Arterial occlusions were performed with a balloon-tipped pulmonary artery catheter that housed pressure transducers immediately proximal and distal to the balloon. Separation of the proximal and distal pressure waveforms during balloon inflation allowed us to precisely define the moment of occlusion. We fit a monoexponential curve to pressure data beginning 200 ms after the onset of occlusion and a biexponential curve to data beginning at the instant of occlusion, with data obtained over a range of vascular states (control, serotonin infusion, histamine infusion). In addition, we investigated the use of sampling of the raw data to estimate capillary pressure. Three of the five literature-based estimates of Ppc yielded values similar to Pdo. The optimal (least average difference from Pdo) interpolation/extrapolation time points of the curve fits varied, depending on the type of curve fitting and the state of the pulmonary vasculature. We also determined that a close approximation of Pdo may be derived from the raw data, as an alternative to exponential curve fitting.

  8. Space Weather Ballooning

    Science.gov (United States)

    Phillips, Tony; Johnson, Sam; Koske-Phillips, Amelia; White, Michael; Yarborough, Amelia; Lamb, Aaron; Herbst, Anna; Molina, Ferris; Gilpin, Justin; Grah, Olivia; Perez, Ginger; Reid, Carson; Harvey, Joey; Schultz, Jamie

    2016-10-01

    We have developed a "Space Weather Buoy" for measuring upper atmospheric radiation from cosmic rays and solar storms. The Buoy, which is carried to the stratosphere by helium balloons, is relatively inexpensive and uses off-the-shelf technology accessible to small colleges and high schools. Using this device, we have measured two Forbush Decreases and a small surge in atmospheric radiation during the St. Patrick's Day geomagnetic storm of March 2015.

  9. Obesity and gastric balloon

    Directory of Open Access Journals (Sweden)

    Mohammed I Yasawy

    2014-01-01

    Full Text Available Background: The obesity epidemic, which is among the most common nutritional disorders, is rising rapidly worldwide. It leads to several health problems such as metabolic disorders, stroke, and even cancer. Efforts to control obesity with exercise and diet have a limited value in obese patients and different approaches to do this have been tried. In this paper, we share our experience with bioenteric intragastric balloon (BIB in treating obesity: Its safety, tolerability, and its efficacy in weight reduction. Materials and Methods: From January 2009 to September 2012, a total of 190 gastric balloons was inserted on patients at the endoscopy unit in King Fahd Hospital of the University, Al-Khobar. This is an evaluation of the first 100 patients. All the patients had a body mass index of over 30 kg/m 2 and were within the age range of 17-55 with a mean age of 32 years. After consent, preballoon investigation tests and anesthesia evaluation, BIB was inserted under monitored anesthesia care sedation in the endoscopy suite. The balloon was filled with 500-700 mls of stained saline. All patients′ were given an analgesic and antiemetic for a week and antisecretory proton pump inhibitor′s for 6 months. Diet and the importance of the exercise were part of the preballoon insertion phase and protocol. The balloon was removed after 6-12 months. Results: The weight loss response to BIB in the 100 patients are classified into four groups: In the uncooperative, noncompliant patients - the maximum weight loss was 7 kg, while in the most compliant patients the weight loss reached up to 39 kg. In addition, there was significant improvement into diabetes mellitus, hypertension, dyslipidemia, and fatty liveras. Its safety and tolerability were extremely acceptable. Conclusion: Our data indicates that in well-selected patients, BIB is an effective device, which with minimum complications helps to achieve body weight loss and resolve many obesity related

  10. Removable partial denture occlusion.

    Science.gov (United States)

    Ivanhoe, John R; Plummer, Kevin D

    2004-07-01

    No single occlusal morphology, scheme, or material will successfully treat all patients. Many patients have been treated, both successfully and unsuccessfully, using widely varying theories of occlusion, choices of posterior tooth form, and restorative materials. Therefore, experience has demonstrated that there is no one righ r way to restore the occlusion of all patients. Partially edentulous patients have many and varied needs. Clinicians must understand the healthy physiologic gnathostomatic system and properly diagnose what is or may become pathologic. Henderson [3] stated that the occlusion of the successfully treated patient allows the masticating mechanism to carry out its physiologic functions while the temporomandibular joints, the neuromuscular mechanism, the teeth and their supporting structures remain in a good state of health. Skills in diagnosis and treatment planning are of utmost importance in treating these patients, for whom the clinician's goals are not only an esthetic and functional restoration but also a lasting harmonious state. Perhaps this was best state by DeVan [55] more than 60 years ago in his often-quoted objective. "The patient's fundamental need is the continued meticulous restoration of what is missing, since what is lost is in a sense irretrievably lost." Because it is clear that there is no one method, no one occlusal scheme, or one material that guarantees success for all patients, recommendations for consideration when establishing or reestablishing occlusal schemes have been presented. These recommendations must be used in conjunction with other diagnostic and technical skills.

  11. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  12. Breakthrough in Mars balloon technology

    Science.gov (United States)

    Kerzhanovich, V. V.; Cutts, J. A.; Cooper, H. W.; Hall, J. L.; McDonald, B. A.; Pauken, M. T.; White, C. V.; Yavrouian, A. H.; Castano, A.; Cathey, H. M.; Fairbrother, D. A.; Smith, I. S.; Shreves, C. M.; Lachenmeier, T.; Rainwater, E.; Smith, M.

    2004-01-01

    Two prototypes of Mars superpressure balloons were flight tested for aerial deployment and inflation in the Earth's stratosphere in June, 2002. One was an 11.3 m diameter by 6.8 m high pumpkin balloon constructed from polyethylene film and Zylon (PBO) tendons, the second was a 10 m diameter spherical balloon constructed from 12 μm thick Mylar film. Aerial deployment and inflation occurred under parachute descent at 34 km altitude, mimicing the dynamic pressure environment expected during an actual Mars balloon mission. Two on-board video cameras were used on each flight to provide real-time upward and downward views of the flight train. Atmospheric pressure and temperature were also recorded. Both prototypes successfully deployed from their storage container during parachute descent at approximately 40 m/s. The pumpkin balloon also successfully inflated with a 440 g charge of helium gas injected over a 1.5-min period. Since the helium inflation system was deliberately retained after inflation in this test, the pumpkin balloon continued to fall to the ocean where it was recovered for post-flight analysis. The less robust spherical balloon achieved only a partial (~70%) inflation before a structural failure occurred in the balloon film resulting in the loss of the vehicle. This structural failure was diagnosed to result from the vigorous oscillatory motion of the partially inflated balloon, possibly compounded by contact between the balloon film and an instrumentation box above it on the flight train. These two flights together represent significant progress in the development of Mars superpressure balloon technology and pave the way for future flight tests that will include post-deployment flight of the prototype balloons at a stable altitude.

  13. Titan Balloon Convection Model Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  14. Buddy balloon for TAVI.

    Science.gov (United States)

    Balkin, Jonathan; Silberman, Shuli; Almagor, Yaron

    2013-11-15

    Percutaneous transfemoral aortic valve replacement is a new rapidly evolving technique that has made significant progress in recent years. The technology is however limitted and in some cases has resulted in failure to deliver the prosthetic valve. We describe a new technique using a buddy balloon, from the contralateral femoral artery, to assist in crossing the native aortic valve in those cases where extreme calcification and or tortuosity have caused the delivery system to hang up on the aortic wall. The technique is easily applied and facilitates the success of the procedure in cases which may otherwise have to be converted to open surgical aortic valve replacement.

  15. A Methane Balloon Inflation Chamber

    Science.gov (United States)

    Czerwinski, Curtis J.; Cordes, Tanya J.; Franek, Joe

    2005-01-01

    The various equipments, procedure and hazards in constructing the device for inflating a methane balloon using a standard methane outlet in a laboratory are described. This device is fast, safe, inexpensive, and easy to use as compared to a hydrogen gas cylinder for inflating balloons.

  16. Nationwide Eclipse Ballooning Project

    Science.gov (United States)

    Colman Des Jardins, Angela; Berk Knighton, W.; Larimer, Randal; Mayer-Gawlik, Shane; Fowler, Jennifer; Harmon, Christina; Koehler, Christopher; Guzik, Gregory; Flaten, James; Nolby, Caitlin; Granger, Douglas; Stewart, Michael

    2016-05-01

    The purpose of the Nationwide Eclipse Ballooning Project is to make the most of the 2017 rare eclipse event in four main areas: public engagement, workforce development, partnership development, and science. The Project is focused on two efforts, both student-led: online live video of the eclipse from the edge of space and the study of the atmospheric response to the eclipse. These efforts, however, involving more than 60 teams across the US, are challenging in many ways. Therefore, the Project is leveraging the NASA Space Grant and NOAA atmospheric science communities to make it a success. The first and primary topic of this poster is the NASA Space Grant supported online live video effort. College and high school students on 48 teams from 31 states will conduct high altitude balloon flights from 15-20 locations across the 8/21/2017 total eclipse path, sending live video and images from near space to a national website. Video and images of a total solar eclipse from near space are fascinating and rare. It’s never been done live and certainly not in a network of coverage across a continent. In addition to the live video to the web, these teams are engaged in several other science experiments as secondary payloads. We also briefly highlight the eclipse atmospheric science effort, where about a dozen teams will launch over one hundred radiosondes from across the 2017 path, recording an unprecedented atmospheric data sample. Collected data will include temperature, density, wind, humidity, and ozone measurements.

  17. Retinal vein occlusion

    Science.gov (United States)

    ... decrease the risk of retinal vein occlusion. These measures include: Eating a low-fat diet Getting regular exercise Maintaining an ideal weight Not smoking Aspirin or other blood thinners may help prevent blockages in the other eye. Controlling diabetes may ...

  18. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J. [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom); Broderick, Nigel [Nottingham University Hospitals, Radiology Department, Nottingham (United Kingdom); Gabra, Hany O.; Elliott, Martin J. [Great Ormond Street Hospital for Children, Department of Cardiothoracic Surgery, London (United Kingdom)

    2010-05-15

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  19. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  20. US Monthly Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Monthly winds aloft summary forms summarizing Pilot Balloon observational data for the United States. Generally labeled as Form 1114, and then transitioning to Form...

  1. Infrarenal Aortic Occlusion

    Science.gov (United States)

    Traverso, L. W.; Baker, J. D.; Dainko, E. A.; Machleder, H. I.

    1978-01-01

    Twenty-eight patients with total occlusion of the infrarenal aorta have been seen at the UCLA Hospitals in the past 11 years. Claudication was the presenting complaint in all but one patient, with one-third having ischemic rest pain. The average age of these patients was 54 years, and their histories revealed a surprising absence of myocardial infarction, stroke, or diabetes, although 40% had essential hypertension. Heavy tobacco use, however, was characteristic of the entire group. Arteriography proved valuable in identifying and characterizing the vascular abnormalities, but posed problems in technique and interpretation. Significant distal arterial disease was detected radiographically in only 21% of these patients. Operative correction of the aortic occlusion was performed on 26 patients, 18 by aortic bypass grafts and eight by aorto-iliac endarterectomy, with one early postoperative death. Although the thrombus extended to the renal artery origins in 77% of the cases, a well-designed technical approach did not require renal artery occlusion. Using serial creatinine determinations, one case of renal insufficiency was detected which was associated with prolonged postoperative hypotension. Although the extent of distal disease was more severe in those who underwent bypass, symptoms of claudication returned earlier and were more prominent in the endarterectomy group. This recurrence of systems was not favorably altered by sympathectomy performed concomitantly with the initial procedure. Even though this condition seems to pose difficult technical obstacles and has a poor prognosis, infrarenal aortic occlusion can be successfully treated by aortic bypass, with favorable long-term results, if particular attention is paid to elements of the preoperative evaluation and the intraoperative technical requirements peculiar to this relatively uncommon disease entity. ImagesFig. 1.Fig. 2.Fig. 3. PMID:646479

  2. Left atrial appendage occlusion

    Directory of Open Access Journals (Sweden)

    Ahmad Mirdamadi

    2013-01-01

    Full Text Available Left atrial appendage (LAA occlusion is a treatment strategy to prevent blood clot formation in atrial appendage. Although, LAA occlusion usually was done by catheter-based techniques, especially percutaneous trans-luminal mitral commissurotomy (PTMC, it can be done during closed and open mitral valve commissurotomy (CMVC, OMVC and mitral valve replacement (MVR too. Nowadays, PTMC is performed as an optimal management of severe mitral stenosis (MS and many patients currently are treated by PTMC instead of previous surgical methods. One of the most important contraindications of PTMC is presence of clot in LAA. So, each patient who suffers of severe MS is evaluated by Trans-Esophageal Echocardiogram to rule out thrombus in LAA before PTMC. At open heart surgery, replacement of the mitral valve was performed for 49-year-old woman. Also, left atrial appendage occlusion was done during surgery. Immediately after surgery, echocardiography demonstrates an echo imitated the presence of a thrombus in left atrial appendage area, although there was not any evidence of thrombus in pre-pump TEE. We can conclude from this case report that when we suspect of thrombus of left atrial, we should obtain exact history of previous surgery of mitral valve to avoid misdiagnosis clotted LAA, instead of obliterated LAA. Consequently, it can prevent additional evaluations and treatments such as oral anticoagulation and exclusion or postponing surgeries including PTMC.

  3. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  4. An alternative treatment of occlusal wear: Cast metal occlusal surface

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar

    2012-01-01

    Full Text Available Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to decrease in the chewing efficiency, loss of vertical dimension of occlusion, denture instability, temporomandibular joint disturbances, etc. There are various treatment options available like, use of highly cross linked acrylic teeth, amalgam or metal inserts on occlusal surface, use of composite, gold or metal occlusal surface, etc. Several articles have described methods to construct gold and metal occlusal surfaces, however, these methods are time-consuming, expensive and requires many cumbersome steps. These methods also requires the patient to be without the prosthesis for the time during which the laboratory procedures are performed. This article presents a quick, simple and relatively inexpensive procedure for construction of metal occlusal surfaces on complete dentures.

  5. Technical note: subclavian artery misplacement of a 12F Shaldon catheter: percutaneous repair with a local closure device under temporary balloon tamponade; Technische Mitteilung: Entfernung eines fehlplatzierten 12F Shaldon Katheters aus der A. subclavia und Abdichtung mittels Verschlusssystem bei temporaerer Ballonblockade

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Katoh, M.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Fussen, R. [Anaesthesiologische Klinik, Medizinisches Zentrum Kreis Aachen GmbH (Germany)

    2006-06-15

    A case of subsequent percutaneous repair using a local closure device with a collagen block (VasoSeal {sup registered}) and temporary balloon tamponade after inadvertent subclavian artery misplacement of a 12F Shaldon catheter is reported. Balloon occlusion safely prevented displacement of collagen into the vascular lumen by occluding the 12F entry site. Furthermore, collagen-induced coagulation was facilitated. (orig.)

  6. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  7. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  8. Pulmonary vein dilatation in a case of total pulmonary vein occlusion: Contemporary approach using a combination of 3D-mapping system and image integration.

    Science.gov (United States)

    Hilbert, Sebastian; Sommer, Philipp; Bollmann, Andreas

    2016-12-01

    Pulmonary vein stenosis (PVS) is a known complication of PV isolation procedures for atrial fibrillation. In this report a case of recurring PV occlusion after repeated percutaneous procedures has been described. Focus is on a novel interventional technique employing a three-dimensional mapping system which enables targeting total occlusion of PVs and on the use of a drug eluting balloon. A focused review of the current literature regarding ongoing limitations of PV stenosis treatment has been provided. © 2015 Wiley Periodicals, Inc.

  9. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  10. Balloon Exoplanet Nulling Interferometer (BENI)

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Woodruff, Robert A.; Vasudevan, Gopal; Ford, Holland; Petro, Larry; Herman, Jay; Rinehart, Stephen; Carpenter, Kenneth; Marzouk, Joe

    2009-01-01

    We evaluate the feasibility of using a balloon-borne nulling interferometer to detect and characterize exosolar planets and debris disks. The existing instrument consists of a 3-telescope Fizeau imaging interferometer with 3 fast steering mirrors and 3 delay lines operating at 800 Hz for closed-loop control of wavefront errors and fine pointing. A compact visible nulling interferometer is under development which when coupled to the imaging interferometer would in-principle allow deep suppression of starlight. We have conducted atmospheric simulations of the environment above 100,000 feet and believe balloons are a feasible path forward towards detection and characterization of a limited set of exoplanets and their debris disks. Herein we will discuss the BENI instrument, the balloon environment and the feasibility of such as mission.

  11. Yellow Balloon in a Briar Patch.

    Science.gov (United States)

    Cooper, Frank; Fitzmaurice, Robert W.

    1978-01-01

    As part of a meteorology unit, sixth grade science students launched helium balloons with attached return postcards. This article describes Weather Service monitoring of the balloons and postcard return results. (MA)

  12. Multi-wire plaque crushing as a novel technique in treating chronic total occlusions

    Institute of Scientific and Technical Information of China (English)

    HAN Ya-ling; WANG Dong-mei; LI Yi; WANG Shou-li; JING Quan-min; MA Ying-yan; WANG Geng; LUAN Bo; WANG Bin; WANG Zhu-lu

    2008-01-01

    Background Failure of balloon catheter passing through the occluded segment accounts for 10%-15% of all procedures during percutaneous coronary intervention(PCI)for chronic total occlusion(CTO).We sought to investigate an original technique for facilitating balloon catheter passing by multi-wire plaque crushing.Methods Between July 2000 and October 2007,152 patients with 164 CTO lesions who had failed balloon passing were treated by multi-wire plaque crushing technique.The main process of this technique was to insert 1 or 2 wires along with the original wire located in the true lumen of CTO lesions after balloon failure for plaque crushing and then to withdraw the crushing wires to get an enlarged lumen inside of the occlusion segment,thus facilitating the balloon passing.Results Both overall lesion and technique success rates were 91.5%(150/164).A total of 211 crushing wires were used during PCI,including 1 crushing wire for 117(71.3%)lesions and 2 crushing wires for 47(28.7%)lesions.Approximately 57.3%(121/211)of all crushing wires were those already used in the same procedure.Technique failure occurred in 14 lesions(8.5%).Technique failure was due to crushing wires entering false lumen(92.9%,13/14)and coronary perforation(7.1%,1/14).Major procedural complications included coronary perforation(1 case)and severe coronary dissection(2 cases),all of which were successfully treated.Conclusions Multi-wire plaque crushing technique is effective in facilitating balloon catheter passing during CTO PCI.It is feasible,economical and relatively safe with a low rate of procedural complications.

  13. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  14. Ballonnen in zee = balloons as marine litter

    NARCIS (Netherlands)

    Franeker, van J.A.

    2008-01-01

    Releasing balloons seems harmless. However, remains of balloons, especially valves and ribbons are becoming a common and persistent type of marine litter found on beaches. Following Dutch Queens day 2007, large numbers of Dutch balloons were found in Normandy, France. Animals may become entangled in

  15. [Temporomandibular joint, occlusion and bruxism].

    Science.gov (United States)

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner.

  16. Pseudoperforation during kissing balloon angioplasty.

    Science.gov (United States)

    Panetta, Carmelo J; Fasseas, Panayotis; Raveendran, Ganesh; Garratt, Kirk N

    2004-11-01

    We describe a case of apparent perforation during kissing balloon angioplasty of a bifurcation lesion. There was no evidence of perforation on follow-up angiography or via intravascular ultrasound. Possible etiologies include minimal perforation that immediately sealed postdeflation or forced contrast into the microvascular bed via a proximal side branch.

  17. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  18. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  19. The modified pulse-spray method using Urokinase in subacute and chronic thrombotic arterial occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Youn Kil; Hahn, Seong Tae; Baek, Jee Hee; Kim, Choon Yul; Shinn, Kyung Sub [The Catholic Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-01-01

    To evaluate the effectiveness and safety of the modified pulse-spray method using Urokinase(UK) in subacute and chronic thrombotic arterial occlusion. Modified pulse-spray methods using UK were performed in seven patients with subacute (1 week-1month) to chronic (1month-5years) occlusive symptoms such as limb pain, claudication and impotence. Angiographic examination revealed thrombotic occlusion of the aorta, common iliac arteries, brachial arterio-venous hemodialysis graft and femoro-popliteal bypass graft. The patients underwent thrombolysis using modified pulse-spray and additional constant infusion of UK. In the presence of underlying stenosis or organized clots, balloon angioplasty or stent placement was performed. Complete lysis was obtained in five of seven patients. For initial lysis, the mean dose of UK was 420,000 units, and the mean modified pulse-spray time was 50 minutes. Mean total dose of UK and mean total time for complete lysis were 800,000 units and 161 minutes, respectively. Thrombolysis of the femoro-popliteal bypass graft failed due to severe occlusion of the distal anastomosis. Partial lysis was achieved in one patient with aorto-illac occlusion, but further thrombolysis was stopped due to bleeding at the puncture site. The modified pulse-spray method using UK is effective in treating subacute and chronic arterial thrombotic occlusion. It augments the speed, safety and efficacy of thrombolysis. When underlying stenosis or organized clots remain after thrombolysis, ballon angioplasty or stent placement would be helpful.

  20. Balloon-occluded retrograde transvenous obliteration for gastric variceal bleeding patient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Seong, Chang Kyu; Kim, Yong Joo; Park, Noh Hyuk [Kyungpook National University School of Medicine, Daegu (Korea, Republic of); Shin, Tae Beom [Dong-A University Medical Center, Pusan (Korea, Republic of); Choi, Jin Soo [Soonchunhyang University College of Medicine, Asan (Korea, Republic of)

    2003-03-01

    To evaluate the technical feasibility and clinical efficacy of balloon-occluded retrograde transvenous obliteration (BRTO) in the treatment of gastric variceal bleeding. Between September 2001 and March 2002, ten patients with gastric variceal bleeding and gastrorenal shunt, underwent BRTO. Three of the ten also had hepatic encephalopathy. To evaluated the gastrorenal shunt and exclude portal vein thrombosis, all patients underwent pre-procedural CT scanning. An occlusion balloon catheter was inserted from the right internal jugular vein and on ballooning was wedged into the left adrenal vein. A sclerosing agent (5% ethanolamine oleate-lipiodol mixture) was injected until the varices were completely filled. In four patients, the collateral veins seen at balloon-occluded adrenal venography were embolized with coils prior to sclerotherapy. Post-procedural follow-up CT (n=3) or endoscopy (n=8) was performed 1-4 weeks later, and both before and after the procedure, hepatic function was also monitored. Treatment was successful in nine cases: the failure involed rupture of the occlusion balloon during inflation, and a transjugular intrahepatic portosystemic shunt was performed. The cessation of bleeding was confirmed endoscopically or clinically; in three patients, follow-up CT showed complete obliteration of the varices. Hepatic function improved in eight patients, but three weeks after the procedure, one expired due to progressive infiltrative hepatoma. The clinical symptoms of the three patients with hepatic encephalopathy showed remarkable improvement. Although more extensive studies and long-term follow up are needed to overcome the limitations of our study, we believe that BRTO is a technically feasible and clinically effective treatment for gastric varices and hepatic encephalopathy.

  1. Tracking people through partial occlusions

    Institute of Scientific and Technical Information of China (English)

    LU Jian-guo; CAI An-ni

    2009-01-01

    This article presents a novel people-tracking approach to cope with partial occlusions caused by scene objects. Instead of predicting when and where the occlusions will occur, a part-based model is used to model the pixel distribution of the target body under occlusion. The subdivided patches corresponding to a template image will be tracked independently using Markov chain Monte Carlo (MCMC) method. A set of voting-based rules is established for the patch-tracking result to verify if the target is indeed located at the estimated position. Experiments show the effectiveness of the proposed method.

  2. Intra-aortic balloon clamp for safe resternotomy in a patient with a giant aneurysm of sinuses of Valsalva.

    Science.gov (United States)

    Zembala, Michal Oscar; Filipiak, Krzysztof; Niklewski, Tomasz; Przybylski, Roman

    2015-02-01

    Despite advances in surgical techniques and postoperative medical management, the mortality rates for cardiac reoperations remain high. The risk is most commonly associated with failed resternotomy complicated by fatal injury to the myocardium or its structures. This short case report documents the first use of an endoluminal balloon occlusive device in order to prevent aneurysmal sack damage and coronary vessel injury in a patient with a giant aortic aneurysm after failed aortic surgery. The safe aortic occlusion allowed for closed-chest cardioplegia delivery and subsequent aortic unloading, thus facilitating a difficult but uneventful resternotomy.

  3. Occlusion, transparency, and lightness.

    Science.gov (United States)

    Albert, Marc K

    2007-11-01

    The lightness of a visual surface is its perceived achromatic reflectance [Adelson, E. H., (2000). Lightness perception and lightness illusions. In M. Gazzaniga (Ed.), The new cognitive neuroscience (2nd ed.) (pp. 339-351) Berlin: Springer; Gilchrist, A. (1999). Lightness perception. In R. W. F. Keil (Ed.), MIT encyclopedia of cognitive science (pp. 471-472). Cambridge: MIT press]. Lightness ranges from black, through various shades of grey, up to white. Anderson and Winawer [Anderson, B., Winawer, J. (2005). Image segmentation and lightness perception. Nature, 434, 79-83] suggested that perceptual decomposition of image luminance into multiple sources in different layers (e.g., perceptual transparency) is critical to the their lightness illusions. However, I show that simple perceptual occlusion evoked by T-junctions will work as well, suggesting that perceptual scission of luminance into multiple layers is unnecessary for such effects. I argue that the lightness illusions presented by Anderson and Winawer involve fundamentally different mechanisms than previously studied lightness illusions, including those involving perceptual transparency.

  4. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  5. Clinical issues in occlusion - Part II.

    Science.gov (United States)

    Patel, Mahul; Alani, Aws

    2015-12-01

    Occlusal diagnosis plays an important role in the planning and subsequent delivery of predictable functional and aesthetic restorations and prostheses. Once an occlusal problem is identified there are a number of techniques and materials that can be utilised to record occlusal relationships, subsequently analyse them and incorporate information obtained into the delivery of tooth restoration or replacement. This paper discusses the clinical and technical aspects of occlusal examination and analysis outlining contemporary and traditional techniques in their utilisation. Aspects of occlusal examination will be revisited; the identification and recording of centric occlusion as well as subsequent articulation will be discussed. The requirement for occlusal splint provision will also be discussed and illustrated.

  6. Scientific ballooning in India: recent developments

    Science.gov (United States)

    Joshi, M. N.; Damle, S. V.

    The National Scientific Balloon Facility (NBF) of the Tata Institute of Fundamental Research (TIFR) has been conducting regular balloon flights for various experiments in the areas of Space Astronomy and Atmospheric Sciences. A continuous improvement in all aspects of Scientific Ballooning through a sustained R and D programme ensures uptodate services and a better handle on the design specifications for the balloon. Recent developments in balloon grade films, continuous improvements in design specifications, balloon manufacturing methods, flight operational procedures and improved balloon flight capabilities have resulted in a greatly improved flight performance in the last five years. A launch capability upgradation programme in terms of new launch spool and new launch vehicle has been initiated to be able to safely launch balloons with gross lifts upto 3500 kg, balloon volumes upto 450,000 m^3 and payloads upto 1400 kg. A series of steps have been initiated to improve long duration flight capabilities. In this paper, we present details on some of these aspects of Scientific Ballooning in India.

  7. [Recanalization of the peripheral arteries by laser thermal balloon angioplasty. 2 years of clinical experience].

    Science.gov (United States)

    Riambau Alonso, V; Masotti Centol, M; Latorre Vilallonga, J; Viver Manresa, E; Crexells Figueres, C; Oriol Palou, A

    1991-01-01

    Laser angioplasty represents an attractive alternative to overcome the limitations of balloon angioplasty. We describe our results with laser thermal balloon angioplasty (LTBA) in the treatment of atherosclerosis obliterans in the lower limbs after two years clinical follow up. We also analyse the influence of lesion characteristics on immediate results. Thirty seven patients (34 men), whose mean age was 58 +/- 9 years, were included in this study. Occlusive arterial disease (Fontaine stage II-IV), with 39 significant haemodynamic arterial lesions were present in all of them. Ankle/brachial Doppler index was O,51 +/- 0,17. Eighteen lesions were located in the iliac area (13 stenoses 2,3 +/- 1 cm of length and 5 occlusions 4,2 +/- 3 cm) and 21 lesions in femoro-popliteal area (5 stenoses 2,6 +/- 2 cm and 16 occlusions 5,7 +/- 3 cm). A percutaneous procedure was used in 38 cases and only in one case a femoral dissection was necessary. The laser source was argon in 26 cases and Nd-YAG in 13. The overall immediate angiographic and clinical success was 85% (89% in iliac lesions and 81% in femoropopliteal lesions; 100% in stenoses and 70% in occlusions). The presence of occlusion (p less than 0,01) and/or calcium (p less than O,05) influenced negatively the immediate results. No major complications were observed. Seven (17%) minor complications occurred, but no emergency surgery was necessary. The ankle/brachial Doppler index after treatment was 0,82 +/- 0,21. Cumulative clinical patency was 91% for successfully treated patients after two years follow up. We conclude that LTBA represents an effective and less aggressive way to treat atherosclerosis obliterans.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  9. Longitudinal stent elongation during retraction of entrapped jailed guidewire in a side branch with balloon catheter support: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Norimasa; Mizuguchi, Yukio; Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp

    2015-01-15

    A 72-year-old man underwent primary percutaneous coronary intervention for a subtotal occlusion in the mid-portion of the left anterior descending artery involving a large diagonal branch. After successful stenting with a 3.0/24 mm bare metal stent, during which, the diagonal branch was protected with a coronary guidewire, conventional retrieval of the jailed guide wire was impossible. Subsequently, several attempts at a strong retraction of the wire with the support of a balloon catheter enabled retrieval of the trapped wire. Optical coherence tomography performed after post-dilatation, revealed that the stent was elongated to the left main coronary artery, and the structure of the strut had become coarse in the proximal portion. The stent was believed to have become entangled with the balloon catheter when the guidewire was being pulled. This case suggests that retrieving the jailed guidewire with a balloon catheter carries a potential risk of entrapment in the deformed stent.

  10. Hyperspectral Polarimeter for Monitoring Balloon Strain Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously unattainable...

  11. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Sabharwal, Tarun, E-mail: tarun_sabharwal@yahoo.co.uk [Guy' s and St. Thomas' Hospitals, NHS Foundation Trust, Department of Radiology (United Kingdom)

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  12. Scientific Ballooning Activities and Recent Developments in Technology and Instrumentation of the TIFR Balloon Facility, Hyderabad

    Science.gov (United States)

    Buduru, Suneel Kumar

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.

  13. Primary angioplasty for infarction due to isolated right ventricular artery occlusion

    Institute of Scientific and Technical Information of China (English)

    Anwar; A; Chahal; Min-Young; Kim; Alexander; N; Borg; Yahya; Al-Najjar

    2014-01-01

    We report an unusual case of an isolated right ventricular infarction with haemodynamic compromise caused by spontaneous isolated proximal occlusion of the right ventricular branch of the right coronary artery(RCA), successfully treated by balloon angioplasty. A 58-yearold gentleman presented with epigastric pain radiating into both arms. Electrocardiograph with right ventricular leads confirmed ST elevation in V4 R and a diagnosis of isolated right ventricular infarction was made. Urgent primary percutaneous intervention was performed which revealed occlusion of the right ventricular branch of the RCA. During the procedure, the patient’s blood pressure dropped to 80/40 mm Hg, and echocardiography showed impaired right ventricular systolic function. Despite aggressive fluid resuscitation, the patient remained hypotensive, continued to have chest pain and persistent electrocardiograph changes, and hence balloon angioplasty was performed on the proximal right ventricular branch which restored flow to the vessel and revealed a severe ostial stenosis. This was treated with further balloon angioplasty which restored TIMI 3 flow with resolution of patient’s symptoms. Repeat echocardiography showed complete resolution of theST-elevation in leads V4 R and V5 R and partial resolution in V1. Subsequent dobutamine-stress echocardiography at 4 wk showed good left and right ventricular contractions. The patient was discharged after a 3-d inpatient stay without any complications.

  14. Occlusion-Aware View Interpolation

    Directory of Open Access Journals (Sweden)

    Janusz Konrad

    2009-01-01

    Full Text Available View interpolation is an essential step in content preparation for multiview 3D displays, free-viewpoint video, and multiview image/video compression. It is performed by establishing a correspondence among views, followed by interpolation using the corresponding intensities. However, occlusions pose a significant challenge, especially if few input images are available. In this paper, we identify challenges related to disparity estimation and view interpolation in presence of occlusions. We then propose an occlusion-aware intermediate view interpolation algorithm that uses four input images to handle the disappearing areas. The algorithm consists of three steps. First, all pixels in view to be computed are classified in terms of their visibility in the input images. Then, disparity for each pixel is estimated from different image pairs depending on the computed visibility map. Finally, luminance/color of each pixel is adaptively interpolated from an image pair selected by its visibility label. Extensive experimental results show striking improvements in interpolated image quality over occlusion-unaware interpolation from two images and very significant gains over occlusion-aware spline-based reconstruction from four images, both on synthetic and real images. Although improvements are obvious only in the vicinity of object boundaries, this should be useful in high-quality 3D applications, such as digital 3D cinema and ultra-high resolution multiview autostereoscopic displays, where distortions at depth discontinuities are highly objectionable, especially if they vary with viewpoint change.

  15. Occlusion-Aware View Interpolation

    Directory of Open Access Journals (Sweden)

    Ince Serdar

    2008-01-01

    Full Text Available Abstract View interpolation is an essential step in content preparation for multiview 3D displays, free-viewpoint video, and multiview image/video compression. It is performed by establishing a correspondence among views, followed by interpolation using the corresponding intensities. However, occlusions pose a significant challenge, especially if few input images are available. In this paper, we identify challenges related to disparity estimation and view interpolation in presence of occlusions. We then propose an occlusion-aware intermediate view interpolation algorithm that uses four input images to handle the disappearing areas. The algorithm consists of three steps. First, all pixels in view to be computed are classified in terms of their visibility in the input images. Then, disparity for each pixel is estimated from different image pairs depending on the computed visibility map. Finally, luminance/color of each pixel is adaptively interpolated from an image pair selected by its visibility label. Extensive experimental results show striking improvements in interpolated image quality over occlusion-unaware interpolation from two images and very significant gains over occlusion-aware spline-based reconstruction from four images, both on synthetic and real images. Although improvements are obvious only in the vicinity of object boundaries, this should be useful in high-quality 3D applications, such as digital 3D cinema and ultra-high resolution multiview autostereoscopic displays, where distortions at depth discontinuities are highly objectionable, especially if they vary with viewpoint change.

  16. Endograft Limb Occlusion in EVAR

    DEFF Research Database (Denmark)

    Taudorf, M; Jensen, L P; Vogt, K C

    2014-01-01

    OBJECTIVE: To assess the incidence and outcome of graft limb occlusions after endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA) in a high volume single centre. To quantify iliac artery tortuosity in patients with AAA and correlate this with limb occlusion. DESIGN: Data were...... collected consecutively and prospectively, and analyzed retrospectively. MATERIALS: Patients treated with Zenith bifurcated stent grafts from January 2000 to December 2010 at a tertiary referral vascular unit were analyzed. Routine regular office follow-up with computed tomography angiography (CTA) and......, subsequently, duplex ultrasound imaging was performed. Patients with limb occlusions were identified. For each index patient, two controls were obtained, one immediately preceding and one following the index patient in the consecutive cohort of EVAR patients. METHODS: Demographics and CTA data on limb graft...

  17. Intragastric balloon and multidisciplinary team

    Directory of Open Access Journals (Sweden)

    R. A. Mazure

    Full Text Available Background: The intragastric balloon is widely used for weight reduction in obese patients, but results are variable. We describe our results enhancing the importance of a Multidisciplinary Team (MT taking part in the treatment. Methods: A retrospective review was done concerning a total of 119 balloons , placed in 116 patients, under endoscopic control and conscious sedation, from May 2001 until August 2006. 49 patients were prepared and recommended to be followed by a MT in a physical unit, at least every 15 days during 6 months. 67 were indicated and followed by other colleagues, without MT. Removal was performed 6 months later. Results: Concerning our 49 patients, mean age was 38, 1 years, 31 female and 18 males, with BMI ranged between 32 and 63, average of 42. The average decrease of weight excess was 31, 85% (-4, 45-80, 4%, and the BMI diminished 5,3 points (from 13,6 to gain of 0,9. The treatment failed in 34,6 % of our patients -including 4 patients lost of follow-up (8, 16%-, compared with 53, 8% of patients without structured MT for selection and follow-up. Physical exercise enhanced markedly the results with 45, 8% of excess of weight loss in women and 39, 7% in males, compared with 14, 6 and 15, 6% in patients who didn't follow the program. The weight loss was mostly fat mass, 89,9% in men and 75,6% in women.- The results maintenance was obtained in 40% of patients one year later. There were no major complications; one balloon had to be removed at 3 weeks because of intolerance, another at 5 months because of gastroesophageal reflux. Conclusions: BIB is an effective help to achieve a short term weight loss in obese patients; nevertheless, good and long lasting results will depend on the modification of life style obtained by a multidisciplinary approach.

  18. Paraplegia following intraaortic balloon circulatory assistance

    Directory of Open Access Journals (Sweden)

    Benício Anderson

    1999-01-01

    Full Text Available Intraaortic balloon counterpulsation is frequently used in patients experiencing severe ventricular dysfunction following maximal drug therapy. However, even with the improvement of percutaneous insertion techniques, the procedure has always been followed by vascular, infectious, and neurological complications. This article describes a case of paraplegia due to intraaortic balloon counterpulsation in the postoperative period of cardiac surgery.

  19. Evolution of occlusal pathology. A literature review.

    OpenAIRE

    2013-01-01

    Introduction: Many of the guidelines on occlusion and treatment alternatives in dentate and partially edentulous patients, are based on concepts raised in the beginning of dentistry. The diversity of the occlusion schools has become some of these concepts complex to understand and apply. This diversity makes difficult the compression of the occlusal physiology and its disorders, hindering the understanding of the occlusal pathology and its proper diagnosis and management. Objective: This is w...

  20. Cephalometric analysis for functional occlusion

    Directory of Open Access Journals (Sweden)

    Ashok Karad

    2016-01-01

    Full Text Available Background: Various elements contributing to good functional occlusion have not been clearly assessed with cephalometrics for the diagnosis of functional problems and their application in clinical practice. The aim of this study, therefore, was to analyze different components of functional occlusion to formulate concise functional cephalometric analysis. Materials and Methods: Eighty-two cases (38 males and 44 females, with class I occlusion and balanced facial profile, were examined based on the selection criteria, and cephalograms were taken in natural head position. All the radiographs were then analyzed using various functional parameters. Results: The mean values of condylar path angle and incisal path angle were 55.83° and 65.67°, respectively, with large deviations. However, both showed positive correlation. The value of the angle of long axis of mandibular incisor with respect to the line joining center of condyle and lower incisor tip was 88.04°. Moreover, the angle between the occlusal plane and horizontal plane was 12.88°. In vertical plane, lower face height (LFH was found to be slightly less than the upper face height. Maxilla contributed around 45% of the LFH while mandible formed about 60%. Furthermore, upper alveolar component (maxillary alveolar height formed more than half of the maxilla (53.79% whereas lower alveolar component (mandibular alveolar height was 74.8% of the mandible. Conclusion: This study has analyzed various components of functional occlusion and formulated a concise functional cephalometric analysis for diagnosis, treatment planning, and assessment of treatment results.

  1. Percutaneous laser thermal angioplasty: initial clinical results with a laser probe in total peripheral artery occlusions.

    Science.gov (United States)

    Cumberland, D C; Sanborn, T A; Tayler, D I; Moore, D J; Welsh, C L; Greenfield, A J; Guben, J K; Ryan, T J

    1986-06-28

    A metal-tipped laser fibre was used during percutaneous angioplasty of femoral/popliteal or iliac artery occlusions in 56 patients. Primary success was achieved in 50 (89%) of these total occlusions, providing a channel for subsequent balloon dilatation. Before the procedure, 18 lesions had been judged untreatable by conventional angioplasty and four of the six failures were in these. Complications directly attributable to the laser probe were one case of vessel perforation and two cases of entry into vessel walls; these had no sequelae. Other acute complications were a distal thrombosis in a non-heparinised patient, requiring local streptokinase treatment, and two reocclusions and one transient peripheral embolic episode in the first 24 hours. The laser probe technique has potential for increasing the proportion of patients suitable for angioplasty.

  2. Airborne Internet Providing Tethered Balloon System

    Directory of Open Access Journals (Sweden)

    Suvriti Dhawan1

    2015-12-01

    Full Text Available In this paper we shall introduce a new system for providing wireless network communication over a specified area using ’lighter than air’ balloons. This technology will replace the existing fiber optic network system. This will be done by using a tethered balloon along with the payload (containing a receiver, a transmitter and a radio communication device.This payload will be suspended from the ground at an altitude (depending on the area of coverage required. Users under this area will be able to access this system directly for internet connectivity. This system can be used over large areas like universities, companies and societies to provide internet facility to their users through Wi-Fi or over an area where the user is specified (commercial purposes. Currently Google is working on similar idea called the ’Google Loon’ in which they use high altitude balloons which float at an altitude twice as high as air planes and the weather. They recently tested this system over New-Zealand by providing internet to their pilot testers on ground. Their balloons not being stationary, move with directional winds and have to be replaced one after the other to maintain consistency. This can be a huge problem over the areas where upper atmospheric winds are not in favorable direction. We can resolve this problem by using our stationary tethered balloon system which can communicate with the loon balloons to provide internet facility over a desired area. Moreover when our balloon will communicate with the loon balloon it will increase the coverage area as the loon balloon has to communicate to a point which is above the ground. Our system will not only replace the existing fiber optic system but it will also be selfsustaining i.e. It will generate its own power using solar panels.

  3. Stratospheric electric field measurements with transmediterranean balloons

    Science.gov (United States)

    de La Morena, B. A.; Alberca, L. F.; Curto, J. J.; Holzworth, R. H.

    1993-01-01

    The horizontal component of the stratospheric electric field was measured using a balloon in the ODISEA Campaign of Transmediterranean Balloon Program. The balloon flew between Trapani (Sicily) and El Arenosillo (Huelva, Spain) along the 39 deg N parallel at a height between 34 and 24 km. The high values found for the field on fair-weather and its quasi-turbulent variation, both in amplitude and direction, are difficult to explain with the classical electric field source. A new source, first described by Holzworth (1989), is considered as possibly causing them.

  4. A balloon-borne integrating nephelometer

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G.S.; Apple, M.L. (Sandia National Labs., Albuquerque, NM (USA)); Weiss, R.E. (Radiance Research, Seattle, WA (USA))

    1990-09-01

    A balloon-borne integrating nephelometer has been successfully developed and flown by Sandia National Laboratories and Radiance Research. This report details instrument design, calibration and data conversion procedure. Free and tethered balloon transport and telemetry systems are described. Data taken during March 1989 South-Central New Mexico free flight ascents are presented as vertical profiles of atmospheric particle scattering coefficient, temperature and balloon heading. Data taken during December 1989 Albuquerque, New Mexico tethered flights are also presented as vertical profiles. Data analysis shows superior instrument performance. 5 refs., 22 figs.

  5. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  6. Occlusal stability in shortened dental arches.

    Science.gov (United States)

    Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F

    2001-02-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.

  7. Tracking facial features with occlusions

    Institute of Scientific and Technical Information of China (English)

    MARKIN Evgeny; PRAKASH Edmond C.

    2006-01-01

    Facial expression recognition consists of determining what kind of emotional content is presented in a human face.The problem presents a complex area for exploration, since it encompasses face acquisition, facial feature tracking, facial expression classification. Facial feature tracking is of the most interest. Active Appearance Model (AAM) enables accurate tracking of facial features in real-time, but lacks occlusions and self-occlusions. In this paper we propose a solution to improve the accuracy of fitting technique. The idea is to include occluded images into AAM training data. We demonstrate the results by running ex periments using gradient descent algorithm for fitting the AAM. Our experiments show that using fitting algorithm with occluded training data improves the fitting quality of the algorithm.

  8. The ELANA technique : Constructing a high flow bypass using a non-occlusive anastomosis on the ICA and a conventional anastomosis on the SCA in the treatment of a fusiform giant basilar trunk aneurysm

    NARCIS (Netherlands)

    Streefkerk, HJN; Wolfs, JFC; Sorteberg, W; Sorteberg, AG; Tulleken, CAF

    2004-01-01

    A patient with a partially thrombosed fusiform giant basilar trunk aneurysm presented with devastating headache and symptoms of progressive brain stem compression. Having an aneurysm inaccessible for endovascular treatment, and after failing a vertebral artery balloon occlusion test, he was offered

  9. A Clinical Series of Resuscitative Endovascular Balloon Occlusion of the Aorta for Hemorrhage Control and Resuscitation

    Science.gov (United States)

    2013-01-01

    27 Sex Male Male Male Male Male Female Mechanism of injury MVC GSW GSW MVC MCC ATV collision Injury Severity Score (ISS) 28 50 9 25 48 43 SBP before...terrain vehicle; GSW, gunshot wound; MCC, motorcycle collision; MVC , motor vehicle collision; NA, not applicable. J Trauma Acute Care Surg Volume 75

  10. 248: Resuscitative Endovascular Balloon Occlusion of the Aorta Improves Survival in Lethal Hemorrhage

    Science.gov (United States)

    2014-01-01

    cohort study with the data reported to the National Emergency Airway Registry for Children (NEAR4KIDS) from 7/2010 to 3/2014. CA was defined as CPR >1min...Patient characteristics include age, gender, indications, and history of difficult airway. Provider characteris- tics include training level, and...and none of the patients had a prior history of seizure disorders. NCSE occurred in 25% (3/12) of patients. Out of the nine patients who did not show

  11. Physiologic Tolerance of Descending Thoracic Aortic Balloon Occlusion in a Swine Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-01-10

    using a modified Seldinger technique. This permitted transduction of the carotid arterial catheter to enable cartoid- flow monitoring, intra- venous ...ameliorated with resuscitation and critical care . Central aortic pressure and cerebral oxygen delivery is significantly improved by the use of REBOA...minutes of hemorrhage shock Resuscitation Phase Resuscitation with shed blood, intra- venous fluid and inotropes Critical Care Phase Sedation

  12. Interventional Radiological Treatment of Perihepatic Vascular Stenosis or Occlusion in Pediatric Patients After Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Uller, Wibke, E-mail: wibke.uller@klinik.uni-regensburg.de [University Medical Center Regensburg, Department of Radiology (Germany); Knoppke, Birgit [KUNO University Children' s Hospital Regensburg, University Medical Center Regensburg (Germany); Schreyer, Andreas G.; Heiss, Peter [University Medical Center Regensburg, Department of Radiology (Germany); Schlitt, Hans J. [University Medical Center Regensburg, Department of Surgery (Germany); Melter, Michael [KUNO University Children' s Hospital Regensburg, University Medical Center Regensburg (Germany); Stroszczynski, Christian [University Medical Center Regensburg, Department of Radiology (Germany); Zorger, Niels [Krankenhaus Barmherzige Brueder, Department of Radiology (Germany); Wohlgemuth, Walter A. [University Medical Center Regensburg, Department of Radiology (Germany)

    2013-12-15

    Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysis (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown.

  13. DISCOVER: Dutch Iliac Stent trial: COVERed balloon-expandable versus uncovered balloon-expandable stents in the common iliac artery: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Bekken Joost A

    2012-11-01

    Full Text Available Abstract Background Iliac artery atherosclerotic disease may cause intermittent claudication and critical limb ischemia. It can lead to serious complications such as infection, amputation and even death. Revascularization relieves symptoms and prevents these complications. Historically, open surgical repair, in the form of endarterectomy or bypass, was used. Over the last decade, endovascular repair has become the first choice of treatment for iliac arterial occlusive disease. No definitive consensus has emerged about the best endovascular strategy and which type of stent, if any, to use. However, in more advanced disease, that is, long or multiple stenoses or occlusions, literature is most supportive of primary stenting with a balloon-expandable stent in the common iliac artery (Jongkind V et al., J Vasc Surg 52:1376-1383,2010. Recently, a PTFE-covered balloon-expandable stent (Advanta V12, Atrium Medical Inc., Hudson, NH, USA has been introduced for the iliac artery. Covering stents with PTFE has been shown to lead to less neo-intimal hyperplasia and this might lower restenosis rates (Dolmatch B et al. J Vasc Interv Radiol 18:527-534,2007, Marin ML et al. J Vasc Interv Radiol 7:651-656,1996, Virmani R et al. J Vasc Interv Radiol 10:445-456,1999. However, only one RCT, of mediocre quality has been published on this stent in the common iliac artery (Mwipatayi BP et al. J Vasc Surg 54:1561-1570,2011, Bekken JA et al. J Vasc Surg 55:1545-1546,2012. Our hypothesis is that covered balloon-expandable stents lead to better results when compared to uncovered balloon-expandable stents. Methods/Design This is a prospective, randomized, controlled, double-blind, multi-center trial. The study population consists of human volunteers aged over 18 years, with symptomatic advanced atherosclerotic disease of the common iliac artery, defined as stenoses longer than 3 cm and occlusions. A total of 174 patients will be included. The control group will undergo

  14. Occlusal status among Yemeni children

    Directory of Open Access Journals (Sweden)

    Nabil M Al-Zubair

    2014-01-01

    Full Text Available Objectives: The purpose of this study was to assess the occlusal status in schoolchildren in Yemen, and to compare the results with those of other studies. Materials and Methods: The sample for this epidemiological survey consisted of 3003 primary school students, half of whom were boys and the other half girls, aged 12 years. The subjects were randomly selected, and none had received previous orthodontic treatment. Variables examined included intra-arch irregularities and malalignment (crowding and spacing in the incisal segments of the arch and midline diastema and discrepancies in occlusal contact relationship (maxillary overjet, mandibular overjet, anterior openbite and antero-posterior molar relation. Results: The results showed that about 26.1% of the subjects were still in the late mixed dentition stage and 73.9% presented with a dentition in the early permanent stage. Normal overjet was found in 55% of the sample. Crowding was observed in 31.4% of the subjects and midline diastema in 14.2%. Conclusion: Occlusal status among Yemeni children was characterized by a relatively high frequency of dental crowding, as well as a relatively high frequency of anterior mandibular overjet (Class III malocclusions.

  15. Shielded Mars Balloon Launcher (SMBL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences, along with its partner Vertigo Industries, proposes a novel approach to deployment of balloon-based payloads into the Martian atmosphere....

  16. Attitude determination for balloon-borne experiments

    CERN Document Server

    Gandilo, N N; Amiri, M; Angile, F E; Benton, S J; Bock, J J; Bond, J R; Bryan, S A; Chiang, H C; Contaldi, C R; Crill, B P; Devlin, M J; Dober, B; Dore, O P; Farhang, M; Filippini, J P; Fissel, L M; Fraisse, A A; Fukui, Y; Galitzki, N; Gambrel, A E; Golwala, S; Gudmundsson, J E; Halpern, M; Hasselfield, M; Hilton, G C; Holmes, W A; Hristov, V V; Irwin, K D; Jones, W C; Kermish, Z D; Klein, J; Korotkov, A L; Kuo, C L; MacTavish, C J; Mason, P V; Matthews, T G; Megerian, K G; Moncelsi, L; Morford, T A; Mroczkowski, T K; Nagy, J M; Netterfield, C B; Novak, G; Nutter, D; O'Brient, R; Pascale, E; Poidevin, F; Rahlin, A S; Reintsema, C D; Ruhl, J E; Runyan, M C; Savini, G; Scott, D; Shariff, J A; Soler, J D; Thomas, N E; Trangsrud, A; Truch, M D; Tucker, C E; Tucker, G S; Tucker, R S; Turner, A D; Ward-Thompson, D; Weber, A C; Wiebe, D V; Young, E Y

    2014-01-01

    An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of SPIDER, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. ...

  17. Retrieving Balloon Data in Flight Project

    Data.gov (United States)

    National Aeronautics and Space Administration —   NASA has plans to fly stratospheric ULDBs for missions of 100 days or more in the next few years. As these balloons circumnavigate the globe multiple times,...

  18. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  19. Magnetometer for Balloons and UAVs Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR project will investigate a new, low-cost approach to atomic magnetometry that is suited for operation from UAVs and research balloons. Atomic...

  20. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  1. Power Systems Design for Long Duration Ballooning

    Science.gov (United States)

    Stilwell, Bryan; Chuzel, Alain

    2016-01-01

    The Columbia Scientific Balloon Facility has been designing and building high-altitude balloon power systems for over 26 years. With that experience, we have found certain types of PV panels, batteries, and charge controllers that are reliable in stratospheric environments. The ultimate goal is to ensure that power systems will provide power reliably throughout the duration of an LDB flight. The purpose of this presentation is to provide some general guidelines and best practices for power system design.

  2. Occlusion of the pig superior sagittal sinus, bridging and cortical veins: multistep evolution of sinus-vein thrombosis.

    Science.gov (United States)

    Fries, G; Wallenfang, T; Hennen, J; Velthaus, M; Heimann, A; Schild, H; Perneczky, A; Kempski, O

    1992-07-01

    Cerebral sinus-vein thrombosis may lead to severe hemodynamic changes, elevated intracranial pressure (ICP), and brain edema. It is supposed that progression of the thrombus from the sinus into bridging and cortical veins plays a key role in the development of these pathophysiological changes, but this hypothesis lacks experimental proof. The aim of this study, using a novel animal model of sinus-vein thrombosis, was to evaluate the effects of a standardized occlusion of the superior sagittal sinus and its bridging and cortical veins on hemodynamic alterations, on brain water content, and on ICP in domestic pigs. In 10 animals, the middle third of the superior sagittal sinus was occluded with a catheter-guided balloon. Five of these pigs received an additional injection of 1 ml fibrin glue into the superior sagittal sinus anterior to the inflated balloon, leading to an obstruction of bridging and cortical veins. In five control animals the balloon was inserted but not inflated. Five pigs underwent cerebral angiography. Four hours after occlusion, the brains were frozen in liquid nitrogen, and coronal slices were examined for Evans blue dye extravasation, regional water content, and histological changes. Occlusion of the superior sagittal sinus alone did not affect ICP or cerebral perfusion pressure (CPP). The additional injection of fibrin glue caused an obstruction of cortical and bridging veins as well as severe increases in mean (+/- standard deviation) ICP to 49.4 +/- 14.3 mm Hg, compared with 8.3 +/- 4.5 mm Hg in sham-treated controls and 7.1 +/- 3.9 mm Hg in animals with occlusion of the superior sagittal sinus alone. There was also a steep fall in the mean CPP to 34.2 +/- 19.6 mm Hg compared with 96.4 +/- 13.8 mm Hg in the control group. White-matter water content anterior to the occlusion site was elevated to 81.9 +/- 3.7 gm/100 gm frozen weight in the fibrin group as compared to 70.7 +/- 2.2 gm/100 gm in controls. Posterior to the occlusion site, water

  3. Imaging Sunlit Aurora from Balloon

    Science.gov (United States)

    Lummerzheim, D.; Zhou, X.

    2012-12-01

    Since 1892 when aurora was first imaged by Martin Brendel, useful auroral images have been obtained only when the aurora is in darkness. While UV imagers onboard satellite provide global auroral dynamics, the sunlit aurora in the UV band is overwhelmed by the UV airglow that has the same wavelengths with the UV auroral emissions. The visible band imaging is feasible only when the aurora is in darkness to avoid the sunlight contamination. However, sunlit aurora (such as dayside aurora) is closely related to the solar wind - magnetosphere - ionosphere coupling. In addition, limited land area has badly restricted the capability of imaging dayside aurora from the northern hemisphere and nightside aurora from the southern hemisphere. We have confirmed that sunlit aurora can be imaged using a near-infrared (NIR) camera on board the balloon platform flying in Antarctica or Arctic. This method provides a unique capability for dayside and conjugate auroral investigations. Scientific questions that can be addressed by such observations include how does the dayside aurora respond to solar wind transient variations? Are auroras hemispherically symmetric? Are auroral forms and their variations under sunlight the same as those in darkness? etc. The new method is also cost effective comparing to space-borne imagers, and offers capabilities not obtainable from space and the ground. With the accomplishment of identifying auroral dynamics in sunlight and darkness, in the south and north simultaneously, our knowledge and understanding of auroral phenomenon and its causes will be expanded.

  4. Branch Retinal Vein Occlusion and Its Management

    Institute of Scientific and Technical Information of China (English)

    Desmond; Archer

    1992-01-01

    The natural course of Branch Retinal Vein Occlusion is determined by the site and completeness of the occlusion, the integrity of arterial perfusion to the affected sector and the efficiency of the developing collateral circulation. Most patients with tributary vein occlusion have some capillary fall out and microvascular incompetence in the distribution of the affected retina and vision is significantly compromised in over 50% of patients who have either chronic macular oedema or ischemia involving the...

  5. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  6. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  7. Occlusion in the combination fixed removable prosthodontic patient.

    Science.gov (United States)

    Ivanhoe, J R; Vaught, R D

    1987-07-01

    The authors provide a review of the critical aspects of occlusion for the combination fixed removable patient. Articular selection and jaw relation techniques are reviewed, and dental materials combinations are recommended for restoring opposing occlusal surfaces. General objectives and specific recommendations for determining and establishing occlusal schemes are made. Tables outlining occlusal scheme, occlusal morphology, and degree of balance are presented.

  8. Completely obstructed colorectal anastomosis: a new non-electrosurgical endoscopic approach before balloon dilatation.

    Science.gov (United States)

    Curcio, Gabriele; Spada, Marco; di Francesco, Fabrizio; Tarantino, Ilaria; Barresi, Luca; Burgio, Gaetano; Traina, Mario

    2010-10-07

    Benign stricture is a relatively common complication of colorectal anastomosis after low anterior resection. On occasion, the anastomosis may close completely. A variety of endoscopic techniques have been described, but there is a lack of data from controlled prospective trials as to the optimal approach. Through-the-scope balloon dilatation is well known and easy to perform. Some case reports describe different endoscopic approaches, including endoscopic electrocision with a papillotomy knife or hook knife. We report a case of a colorectal anastomosis web occlusion, treated without electrocision. Gastrografin enema and sigmoidoscopy showed complete obstruction at the anastomotic site due to the presence of an anastomotic occlusive web. In order to avoid thermal injuries, we decided to use a suprapapillary biliary puncture catheter. The Artifon catheter was inserted into the center of the circular staple line at the level of the anastomosis, and fluoroscopic identification of the proximal bowel was obtained with dye injection. A 0.025-inch guidewire was then passed through the catheter into the colon and progressive pneumatic dilatation was performed. The successful destruction of the occlusive web facilitated passage of the colonoscope, allowing evaluation of the entire colon and stoma closure after three months of follow-up. The patient tolerated the procedure well, with no complications. This report highlights an alternative non-electrosurgical approach that uses a new device that proved to be safe and useful.

  9. Occlusion on oral implants: current clinical guidelines.

    Science.gov (United States)

    Koyano, K; Esaki, D

    2015-02-01

    Proper implant occlusion is essential for adequate oral function and the prevention of adverse consequences, such as implant overloading. Dental implants are thought to be more prone to occlusal overloading than natural teeth because of the loss of the periodontal ligament, which provides shock absorption and periodontal mechanoreceptors, which provide tactile sensitivity and proprioceptive motion feedback. Although many guidelines and theories on implant occlusion have been proposed, few have provided strong supportive evidence. Thus, we performed a narrative literature review to ascertain the influence of implant occlusion on the occurrence of complications of implant treatment and discuss the clinical considerations focused on the overloading factors at present. The search terms were 'dental implant', 'dental implantation', 'dental occlusion' and 'dental prosthesis'. The inclusion criteria were literature published in English up to September 2013. Randomised controlled trials (RCTs), prospective cohort studies and case-control studies with at least 20 cases and 12 months follow-up interval were included. Based on the selected literature, this review explores factors related to the implant prosthesis (cantilever, crown/implant ratio, premature contact, occlusal scheme, implant-abutment connection, splinting implants and tooth-implant connection) and other considerations, such as the number, diameter, length and angulation of implants. Over 700 abstracts were reviewed, from which more than 30 manuscripts were included. We found insufficient evidence to establish firm clinical guidelines for implant occlusion. To discuss the ideal occlusion for implants, further well-designed RCTs are required in the future.

  10. The prevalence of questionable occlusal caries

    DEFF Research Database (Denmark)

    Makhija, Sonia K; Gilbert, Gregg H; Funkhouser, Ellen;

    2012-01-01

    Questionable occlusal caries (QOC) can be defined as clinically suspected caries with no cavitation or radiographic evidence of occlusal caries. To the authors' knowledge, no one has quantified the prevalence of QOC, so this quantification was the authors' objective in conducting this study...

  11. Japan-Indo collaboration on balloon observations

    Science.gov (United States)

    Makino, Fumiyoshi

    Japan-Indo collaboration on balloon observations of cosmic X-ray sources was started in 1969 by the late S. Hayakawa of Nagoya Univ. and B. V. Sreekantan of TIFR. Cosmic background X-ray and soft gamma-ray spectra, simultaneous X-ray and optical flux variation, and size of X-ray emitting region of Crab Nebula were observed successfully by balloon flights at Hyderabad in 1969-1975. H. Shibai of Nagoya Univ. and T. N. Rengarajan of TIFR have organized collaboration on far infrared sky survey at wavlength of 150 micron emitted from CII. By employing improved detectors, CII distribution of Orion Nebula has been obtained in good accuracy by more than ten balloon flights in 1999-2008.

  12. Near ultraviolet spectrograph for balloon platform

    Science.gov (United States)

    Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    2015-06-01

    Small and compact scientific payloads may be easily designed constructed and own on high altitude balloons. Despite the fact that large orbital observatories provide accurate observations and statistical studies of remote and/or faint space sources, small telescopes on board balloons or rockets are still attractive because of their low cost and rapid response time. We describe here a near ultraviolet (NUV) spectrograph designed to be own on a high{altitude balloon platform. Our basic optical design is a modified Czerny-Turner system using off the shelf optics. We compare different methods of aberration corrections in such a system. We intend the system to be portable and scalable to different telescopes. The use of reflecting optics reduces the transmission loss in UV. We plan on using an image intensified CMOS sensor operating in photon counting mode as the detector of choice.

  13. 75 FR 33838 - National Environmental Policy Act; Scientific Balloon Program

    Science.gov (United States)

    2010-06-15

    ... SPACE ADMINISTRATION National Environmental Policy Act; Scientific Balloon Program AGENCY: National... Draft Programmatic Environmental Assessment (PEA) and Draft Finding of No Significant Impact (FONSI) for NASA's Scientific Balloon Program. SUMMARY: Pursuant to the National Environmental Policy Act of...

  14. Symposium on semiprecision attachments in removable partial dentures. Occlusal relationships.

    Science.gov (United States)

    Whitbeck, P; Ivanhoe, J R

    1985-01-01

    This article discusses current concepts of occlusion and describes the methods of creating a physiologic occlusion for the partially edentulous patient. Specific recommendations are made for choices of materials, techniques, and occlusal schemes for various edentulous situations.

  15. Computerized analysis of occlusal contacts in bruxism patients treated with occlusal splint therapy

    Science.gov (United States)

    Kılınç, Halil İbrahim; Tuna, Süleyman Hakan; Özcan, Nihal

    2013-01-01

    PURPOSE Occlusal splints are commonly used to prevent tooth wear caused by bruxism. However, the effects of splints on occlusion are still unclear. Although it is rarely alluded in literature, splints can provoke severe occlusal alterations and other complications. This study was aimed to identify differences in the responses of individuals with bruxism and healthy individuals to a full-arch maxillary stabilization splint in terms of occlusal changes. MATERIALS AND METHODS Occlusal contacts in 20 (5 male, 15 female) bruxism patients and 20 (5 male, 15 female) controls with normal occlusion were evaluated before and after occlusal splint therapy. T-Scan III, a computerized occlusal analysis system, was used to simultaneously measure occlusion and disclusion times as well as left-right and anterior-posterior contact distributions before splint therapy and 3 months after therapy. Wilcoxon and Mann-Whitney U tests were used for statistical analyses (α=.05). RESULTS No differences were found in the posterior contact of bruxism patients before and after stabilization splint treatment. However, differences in posterior contact were observed between bruxists and normal individuals prior to treatment, and this difference disappeared following treatment. CONCLUSION The results of this study showed the use of a stabilization splint may not have an effect on occlusion. However, the area of posterior occlusal contact among bruxists was found to be greater than that of normal individuals. According to this study, the clinical use of splints may be harmless. PMID:24049566

  16. [Occlusal vertical dimension in removable complete dentures].

    Science.gov (United States)

    den Haan, R; Witter, D J

    2011-12-01

    In removable complete dentures, the occlusal vertical dimension is an important factor for patients' satisfaction with aesthetics. An excessively reduced occlusal vertical dimension is especially likely to lead to complaints about aesthetics, whereas an increased occlusal vertical dimension may lead to discomfort and a decision not to wear the complete dentures. There are various methods for determining the occlusal vertical dimension in complete dentures, based on the vertical dimension in the rest position of the mandible or on phonetics. However, none of the methods have proven to be clearly superior, in terms of reliability, than the others. The assessment of the occlusal vertical dimension will become more reliable if several methods are used simultaneously. Moreover, knowledge of the characteristics of the ageing face is essential.

  17. Aortoiliac occlusive disease masquerading as cerebrovascular accident

    Directory of Open Access Journals (Sweden)

    Nandeesh B

    2007-01-01

    Full Text Available Acute aortoiliac occlusion is an unusual but potentially catastrophic condition causing acute limb ischemia and associated with early and high rates of mortality and morbidity. It is caused by either embolic occlusion of the infra renal aorta at the bifurcation or beyond or thrombosis of the abdominal aorta and its large terminal branches. Neurological symptoms are rare manifestation of acute aortoiliac occlusion and when neurological symptoms predominate, patients are mistakenly considered to have cerebrovascular event. We present a 60-year-old man with atherosclerotic thrombotic occlusion of the left common iliac artery causing acute painful monoplegia. We mistook the acute monoplegia due to acute limb ischemia for cerebrovascular accident. Pathologic examination revealed a firm thrombus occluding the origin of left common iliac artery and extending along the length of the vessel. Acute aortic iliac occlusion can masquerade as a cerebrovascular stroke and a thorough clinical evaluation and imaging studies allow early diagnosis and instituting life-saving treatment timely.

  18. Virtual occlusion in planning orthognathic surgical procedures.

    Science.gov (United States)

    Nadjmi, N; Mollemans, W; Daelemans, A; Van Hemelen, G; Schutyser, F; Bergé, S

    2010-05-01

    Accurate preoperative planning is mandatory for orthognathic surgery. One of the most important aims of this planning process is obtaining good postoperative dental occlusion. Recently, 3D image-based planning systems have been introduced that enable a surgeon to define different osteotomy planes preoperatively and to assess the result of moving different bone fragments in a 3D virtual environment, even for soft tissue simulation of the face. Although the use of these systems is becoming more accepted in orthognathic surgery, few solutions have been proposed for determining optimal occlusion in the 3D planning process. In this study, a 3D virtual occlusion tool is presented that calculates a realistic interaction between upper and lower dentitions. It enables the surgeon to obtain an optimal and physically possible occlusion easily. A validation study, including 11 patient data sets, demonstrates that the differences between manually and virtually defined occlusions are small, therefore the presented system can be used in clinical practice.

  19. Particle Astrophysics in NASA's Long Duration Balloon Program

    CERN Document Server

    Gorham, Peter W

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons.

  20. There is a Text in 'The Balloon'

    DEFF Research Database (Denmark)

    Elias, Camelia

    2009-01-01

    From the Introduction: Camelia Elias' "There is a Text in 'The Balloon': Donald Barthelme's Allegorical Flights" provides its reader with a much-need and useful distinction between fantasy and the fantastic: "whereas fantasy in critical discourse can be aligned with allegory, in which a supernatu......From the Introduction: Camelia Elias' "There is a Text in 'The Balloon': Donald Barthelme's Allegorical Flights" provides its reader with a much-need and useful distinction between fantasy and the fantastic: "whereas fantasy in critical discourse can be aligned with allegory, in which...

  1. Cutting balloon angioplasty for intrastent restenosis treatment

    Directory of Open Access Journals (Sweden)

    João Orávio de Freitas Jr

    1999-05-01

    Full Text Available We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA, inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cutting balloon angioplasty using low inflation pressures achieved important luminal gains, in these two cases of intrastent restenosis. Further studies are necessary before the effectiveness of this procedure can be precisely defined.

  2. On the inflation of a rubber balloon

    Science.gov (United States)

    Vandermarlière, Julien

    2016-12-01

    It is a well-known fact that it is difficult to start a balloon inflating. But after a pressure peak that occurs initially, it becomes far easier to do it! The purpose of this article is to establish the experimental pressure-radius chart for a rubber balloon and to compare it to the theoretical one. We will demonstrate that the barometer of a smartphone is a very suitable tool to reach this goal. We hope that this phenomenon will help students realize that sometimes very simple questions can lead to very interesting and counterintuitive science.

  3. High altitude balloon experiments at IIA

    Science.gov (United States)

    Nayak, Akshata; Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    Recent advances in balloon experiments as well as in electronics have made it possible to fly scientific payloads at costs accessible to university departments. We have begun a program of high altitude ballooning at the Indian Institute of Astrophysics, Bengaluru. The primary purpose of this activity is to test low-cost ultraviolet (UV) payloads for eventual space flight, but we will also try scientific exploration of the phenomena occurring in the upper atmosphere, including sprites and meteorite impacts. We present the results of the initial experiments carried out at the CREST campus of IIA, Hosakote, and describe our plans for the future.

  4. Clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting

    Directory of Open Access Journals (Sweden)

    Xiang-yu CAO

    2016-12-01

    Full Text Available Objective To explore the clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting to predict the reflux of perforator veins after operation. Methods A total of 93 patients (including 51 with cerebral venous sinus stenosis and intracranial hypertension and 42 with intractable pulsatile tinnitus caused by cerebral venous sinus stenosis who were treated by stent implantation were analyzed retrospectively. Among those patients, the diameter of transverse and sigmoid sinuses of 63 cases were measured based on angiography, and stent was selected according to the measurement result. The other 30 cases were given angiography on ipsilateral carotid artery or vertebral artery when the balloon was dilated in the venous sinus to confirm the reflux of perforator veins. If the venous reflux decreased in the angiography, stent with diameter 1-2 mm less than that of venous sinus could be selected.  Results The success rate of stenting was 100% (93/93. In 63 cases, 45 cases were planted 9 mm × 40 mm stents, 15 were planted 8 mm × 40 mm stents, 3 were planted 7 mm × 40 mm stents. The average diameter of stents was (8.67 ± 0.68 mm. There were 11 cases (17.46% with slow perforator venous reflux after operation. In the other 30 cases, 3 cases were planted 8 mm × 40 mm stents, 11 were planted 7 mm × 40 mm stents, and 16 were planted 6 mm × 40 mm stents. The average diameter of stents was (7.57 ± 0.67 mm. There was only one case (3.33% with slow perforator venous reflux after operation. The difference of stent diameter between 2 groups was statistically significant (t = 15.632, P = 0.001. The occurrence rate of perforator vein occlusion after operation between 2 groups was significantly different (adjusted χ 2 = 60.065, P = 0.001.  Conclusions Perforator vein occlusion after cerebral venous sinus stenting is common complication. Balloon dilatation angiography could predict the possibility of perforator vein

  5. Idiopathic pediatric retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Manayath George

    2010-01-01

    Full Text Available We report a case of branch retinal artery occlusion (BRAO in a healthy young girl. An eight-year-old girl presented with sudden loss of vision in her left eye. She had a pale retina with macular edema consistent with extensive BRAO. A thorough workup was performed to determine any etiologic factor. All test results were within normal limits. Her visual acuity improved from finger counting to 20/40 over two weeks, on immediate treatment with intravenous steroids (methyl prednisolone. This case suggests that BRAO can occur in healthy children without any detectable systemic or ocular disorders and a dramatic improvement may be achieved with prompt treatment with intravenous steroids.

  6. Auditory Risk of Exploding Hydrogen-Oxygen Balloons

    Science.gov (United States)

    Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.

    2010-01-01

    Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…

  7. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  8. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine...

  9. Occlusion for maxillary dentures opposing osseointegrated mandibular prostheses.

    Science.gov (United States)

    Denissen, H W; Kalk, W; van Waas, M A; van Os, J H

    1993-01-01

    This paper presents a combination of several occlusal concepts designed to contribute to the successful use of maxillary dentures in opposition to osseointegrated mandibular prostheses. To ensure a positive outcome when designing such an occlusion, three factors must be considered: patient satisfaction, maxillary anterior bone preservation, and mandibular arch shortening. It is recommended that for centric occlusion the molars have a lingual contact occlusion, the premolars have a buccal contact occlusion, and the anterior teeth have an open occlusal relationship. For an eccentric occlusion, a balanced articulation is favored instead of mutually protected occlusion.

  10. Single-balloon versus double-balloon bipedicular kyphoplasty for osteoporotic vertebral compression fractures.

    Science.gov (United States)

    Wang, Heng; Sun, Zhenzhong; Wang, Zhiwen; Jiang, Weimin

    2015-04-01

    Twenty-eight patients with osteoporotic vertebral compression fractures (OVCF) were treated with single-balloon bipedicular kyphoplasty (Group A), and 40 patients were treated with double-balloon bipedicular kyphoplasty (Group B). Visual Analogue Scale (VAS) score, vertebral height, and kyphotic angle (KA) were evaluated pre-operatively, post-operatively (3 days after surgery) and at final follow-up. Operative time, X-ray exposure frequency and costs were recorded. The mean operative time and X-ray exposure frequency in Group A were greater than in Group B (pkyphoplasty is a safe and cost-effective surgical method for the treatment of OVCF. It can achieve pain relief comparable with double-balloon bipedicular kyphoplasty. However, double-balloon bipedicular kyphoplasty is more efficacious in terms of the restoration of vertebral height and reduction of KA, and the operative time and X-ray exposure frequency are lower.

  11. Experiments with Helium-Filled Balloons

    Science.gov (United States)

    Zable, Anthony C.

    2010-12-01

    The concepts of Newtonian mechanics, fluids, and ideal gas law physics are often treated as separate and isolated topics in the typical introductory college-level physics course, especially in the laboratory setting. To bridge these subjects, a simple experiment was developed that utilizes computer-based data acquisition sensors and a digital gram scale to estimate the molar mass of the gas in an inflated balloon. In this experiment, the comparable density of an inflated balloon to that of atmospheric air introduces a significant role for buoyancy that must be accounted for. The ideal gas law approximation is assumed for both the isolated gas mixture within the balloon and the surrounding air, which defines the relationship between the gas pressure, volume, temperature, and molar quantity. Analysis of the forces associated with the inflated balloon with the incorporation of Archimedes' principle and the ideal gas law into Newton's second law results in an experimental method for the measurement of the molar mass and mole fraction of a gas that is easy to implement yet academically challenging for students. The following narrative describes the basic setup of this experiment, along with a sample set of data as acquired and analyzed by a typical physics student from one of my classes.

  12. Pumpkins and onions and balloon design

    Science.gov (United States)

    Winker, J. A.

    The reach for a capability to make long flights (months) with heavy payloads (tonnes) has long been pursued. The closest we have come is with polar flights devoid of a significant diurnal cycle. Superpressure technology, with its ability to survive diurnal cycles, is an obvious choice, but materials limitations have been an obstacle to realizing these ambitious goals. Now comes an assortment of new synthetic materials, coupled with a special variety of superpressure balloon which, in combination, is poised to yield a solution for our enhanced duration/payload quest. In this paper we are looking not at materials, but only at a balloon concept. This concept is a "natural shape" oblate spheroid balloon whose shape is chosen to exploit properties of component materials, particularly newly available ones. The current variation of this concept is called a "pumpkin" balloon. The most visible work on this shape is that done by France's CNES, Japan's ISAS, and in the USA by NASA's Wallops Flight Facility. But the basic design idea is not new; it extends back at least a half century. This paper traces the origins of the shape, its evolution through various iterations, and it speculates on some of the recent thinking regarding construction details.

  13. Evolution of occlusal pathology. A literature review.

    Directory of Open Access Journals (Sweden)

    Camilo Guerrero

    2013-08-01

    Full Text Available Introduction: Many of the guidelines on occlusion and treatment alternatives in dentate and partially edentulous patients, are based on concepts raised in the beginning of dentistry. The diversity of the occlusion schools has become some of these concepts complex to understand and apply. This diversity makes difficult the compression of the occlusal physiology and its disorders, hindering the understanding of the occlusal pathology and its proper diagnosis and management. Objective: This is why we conducted a literature review about oclusal physiology and pathology, in order to gather information based on scientific evidence, which in order to clarify concepts and homogenize knowledge about physiological and morphological changesof thestomatognathic system, associated toocclusal alterations, allowing the future standardization of the occlusal diagnostic process at the Faculty of Dentistry of the National University of Colombia. Methodology: A search was conducted inMedLine, PubMed, Ovid, Ebsco, ScienceDirect and Hinari-Healthinternetwork using the Mesh terms: "Dental Occlusion" - "Stomatognathic System" - "masticatory System" - Temporomandibular Joint and the bibliographies of papers and review articles that had direct relationship to the topic; the publication deadline was not taken into account. In total, 79 articles, 10 texts and 7 websites were obtained. Conclusion: Occlusal pathology is an evolutionary process that might affect the form and/or function of any of the components of the stomatognathic system. Occlusal Harmony is a state in which each part of the system works in concert with the others to fulfill the functions of mastication, speech and swallowing; oral rehabilitation should be directed toward obtaining a harmonious occlusion.

  14. Stratospheric Balloon Platforms for Near Space Access

    Science.gov (United States)

    Dewey, R. G.

    2012-12-01

    For over five decades, high altitude aerospace balloon platforms have provided a unique vantage point for space and geophysical research by exposing scientific instrument packages and experiments to space-like conditions above 99% of Earth's atmosphere. Reaching altitudes in excess of 30 km for durations ranging from hours to weeks, high altitude balloons offer longer flight durations than both traditional sounding rockets and emerging suborbital reusable launch vehicles. For instruments and experiments requiring access to high altitudes, engineered balloon systems provide a timely, responsive, flexible, and cost-effective vehicle for reaching near space conditions. Moreover, high altitude balloon platforms serve as an early means of testing and validating hardware bound for suborbital or orbital space without imposing space vehicle qualifications and certification requirements on hardware in development. From float altitudes above 30 km visible obscuration of the sky is greatly reduced and telescopes and other sensors function in an orbit-like environment, but in 1g. Down-facing sensors can take long-exposure atmospheric measurements and images of Earth's surface from oblique and nadir perspectives. Payload support subsystems such as telemetry equipment and command, control, and communication (C3) interfaces can also be tested and operationally verified in this space-analog environment. For scientific payloads requiring over-flight of specific areas of interests, such as an active volcano or forest region, advanced mission planning software allows flight trajectories to be accurately modeled. Using both line-of-sight and satellite-based communication systems, payloads can be tracked and controlled throughout the entire mission duration. Under NASA's Flight Opportunities Program, NSC can provide a range of high altitude flight options to support space and geophysical research: High Altitude Shuttle System (HASS) - A balloon-borne semi-autonomous glider carries

  15. Retinal occlusive vasculer disorder and rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Huseyin Ortak

    2013-03-01

    Full Text Available Rheumatoid arthritis is a systemic inflammatory disease that affected older women with many ocular manifestations. Also, these systemic diseases can cause retinal vein occlusion and arterial occlusion that lead to serious and permanent visual loss. Rheumatoid arthritis's the most common manifestation is that retinal vasculitis and retinal vascular complications are associated with this complication. In this review, retinal vascular occlusive diseases are presented to associated with rheumatoid arthritis in literature. Rheumatoid arthritis and its complications have been outlined and was made to create a new perspective. [J Contemp Med 2013; 3(1.000: 71-73

  16. Measurements of gondola motion on a stratospheric balloon flight

    CERN Document Server

    Safonova, Margarita; Sreejith, A G; Sarpotdar, Mayuresh; Ambily, S; Prakash, Ajin; Mathew, Joice; Murthy, Jayant; Anand, Devarajan; Kapardhi, B V N; Kumar, B Suneel; Kulkarni, P M

    2016-01-01

    Balloon experiments are an economically feasible method of conducting observations in astronomy that are not possible from the ground. The astronomical payload may include a telescope, a detector, and a pointing/stabilization system. Determining the attitude of the payload is of primary importance in such applications, to accurately point the detector/telescope to the desired direction. This is especially important in generally unstable lightweight balloon flights. However, the conditions at float altitudes, which can be reached by zero pressure balloons, could be more stable, enabling accurate pointings. We have used the Inertial Measurement Unit (IMU), placed on a stratospheric zero pressure balloon, to observe 3-axis motion of a balloon payload over a fight time of 4.5 hours, from launch to the float altitude of 31.2 km. The balloon was launched under nominal atmospheric conditions on May 8th 2016, from a Tata Institute of Fundamental Research Balloon Facility, Hyderabad.

  17. Report on the Activities of National Balloon Facility, Hyderabad

    Science.gov (United States)

    Vasudevan, Rajagopalan; Sreenivasan, S.; Suneel Kumar, B.; Kulkarni, P. M.

    2012-07-01

    More than five and half decades back, the Indian Balloon Group at Tata Institute of Fundamental Research, Mumbai started development of stratospheric zero pressure balloon technology and today it is one among the leading balloon groups in the world. For the past 40 years, the Institute has been operating a Scientific Balloon Facility at Hyderabad and carried out 478 balloon flights for various disciplines of space sciences like primary cosmic ray studies, X ray, Gamma Ray, Infra Red Astronomies and Atmospheric science maintaining 100% success rate during the past nine years. The Balloon Facility has the capability to build balloons of volume up to 750,000 Cu.M. as well as carrying out R & D in all aspects of scientific ballooning like balloon engineering, balloon material development, general and flight support instrumentation. A continued effort in R & D for ultra thin balloon material for High Altitude Sounding Flights has resulted in lowering the thickness of the proven indigenous Antrix film initially from 6 to 3.8 microns in the first phase and further reduction to 2.7 microns in the second phase. A test balloon of volume 5000 Cu.M. using the 2.7 micron film attained a record altitude of 45.0 Km. amsl with 1 Kg. GPS sonde payload. A 60,000 Cu.M. balloon fabricated out of 3.8 micron film capable of reaching 47 Km. Altitude with 10 Kg. Payload is awaiting trial. This report briefly describes our balloon activities during the past two years. In atmospheric sciences, aerosol studies were made with OPC,QCM,Aethelometer, Nephelometer,MWR, CIMEL Sun Photometer and Raman LIDAR.Measuments of vertical profile of Meteorological parameters and ozone upto stratosphere using GPS Radiosonde and Ozone sonde is made respectively.Study of Ionospheric tomography is done with CADI and CRABEX.

  18. Pulmonary veno-occlusive disease.

    Science.gov (United States)

    Montani, David; Lau, Edmund M; Dorfmüller, Peter; Girerd, Barbara; Jaïs, Xavier; Savale, Laurent; Perros, Frederic; Nossent, Esther; Garcia, Gilles; Parent, Florence; Fadel, Elie; Soubrier, Florent; Sitbon, Olivier; Simonneau, Gérald; Humbert, Marc

    2016-05-01

    Pulmonary veno-occlusive disease (PVOD) is a rare form of pulmonary hypertension (PH) characterised by preferential remodelling of the pulmonary venules. In the current PH classification, PVOD and pulmonary capillary haemangiomatosis (PCH) are considered to be a common entity and represent varied expressions of the same disease. The recent discovery of biallelic mutations in the EIF2AK4 gene as the cause of heritable PVOD/PCH represents a major milestone in our understanding of the molecular pathogenesis of PVOD. Although PVOD and pulmonary arterial hypertension (PAH) share a similar clinical presentation, with features of severe precapillary PH, it is important to differentiate these two conditions as PVOD carries a worse prognosis and life-threatening pulmonary oedema may occur following the initiation of PAH therapy. An accurate diagnosis of PVOD based on noninvasive investigations is possible utilising oxygen parameters, low diffusing capacity for carbon monoxide and characteristic signs on high-resolution computed tomography of the chest. No evidence-based medical therapy exists for PVOD at present and lung transplantation remains the preferred definitive therapy for eligible patients.

  19. Balloon-expandable covered stent therapy of complex endovascular pathology.

    Science.gov (United States)

    Giles, Heath; Lesar, Christopher; Erdoes, Luke; Sprouse, Richard; Myers, Stuart

    2008-11-01

    restenosis rate included two renal artery occlusions in patients noncompliant with clopidogrel use and resulted in ipsilateral kidney loss in both patients. In-stent peak systolic velocities decreased significantly (p<0.05) from preoperation to 12 months in iliac stents and to 18 months in renal stents. Ankle-brachial index increased significantly in iliac stents from preoperation (0.62+/-0.18) to 18 months (0.86+/-0.16). Successful exclusion of atheromatous lesions and aneurysm/dissection/endoleak was 100%. Access-site complications occurred in 6%: pseudoaneurysm (n=2), dissection (n=1), and bleeding (n=1). Balloon-expandable covered stents have an acceptable primary patency with an excellent assisted patency after salvage angioplasty. The clinical utility of this technology is broad for the treatment of aneurysms, extravasation, unstable atheromatous lesions, and recurrent in-stent restenosis.

  20. Smile line and occlusion: An epidemiological study

    Directory of Open Access Journals (Sweden)

    Mahsa Harati

    2013-01-01

    Conclusion: Within the limitations of such studies, it might be concluded that there is a significant and important relation between some occlusal parameters and smile design, which must be considered.

  1. Branch retinal artery occlusion in Susac's syndrome

    Directory of Open Access Journals (Sweden)

    Ricardo Evangelista Marrocos de Aragão

    2015-02-01

    Full Text Available Susac's syndrome is a rare disease attribuited to a microangiopathy involving the arterioles of the cochlea, retina and brain. Encefalopathy, hearing loss, and visual deficits are the hallmarks of the disease. Visual loss is due to multiple, recurrent branch arterial retinal occlusions. We report a case of a 20-year-old women with Susac syndrome presented with peripheral vestibular syndrome, hearing loss, ataxia, vertigo, and vision loss due occlusion of the retinal branch artery.

  2. Current possibilities in occlusal caries management

    Directory of Open Access Journals (Sweden)

    Hrvoje Jurić

    2013-11-01

    Full Text Available Dental caries is a multifactorial disease that affects most populations throughout the world and it is still the primary cause of oral pain and tooth loss. The occlusal surfaces of posterior teeth are the most vulnerable sites for dental caries due to their anatomy. Therefore, the aim of the following article is to summarize current knowledge on occlusal caries development and the possibilities of its prevention. Although the overall caries rate today has fallen for populations in industrialized countries, the rate of occlusal surface caries has not decreased. This may be explained with fact that topically applied fluorides and their mode of action prevent caries better on smooth than on occlusal surfaces. As we know, tooth decay of first permanent molars causes a great deal of different short and long term difficulties for patients. Therefore, there is a continuous need for implementation of programs for caries prevention in permanent teeth. Nowadays, we like to treat our patients by minimally invasive methods. A very important step in our effective preventive treatment is sealing pits and fissures as a cornerstone of occlusal caries management. Reliable assessment of caries activity is also very important for defining treatment needs and plans. A very important decision, which should be made during occlusal caries management, is the selection of restorative material according to the treatment plan. Conclusion. Current possibilities in occlusal caries prevention and management are very effective. Therefore, dentists today do not have any excuse for avoiding the philosophy of Minimally Invasive Dentistry, especially when we talk about caries management of occlusal surfaces in permanent molars.

  3. [Lingualized occlusion in the South African context].

    Science.gov (United States)

    Oberholzer, T G; Geerts, G A V M

    2002-01-01

    The search for the ideal artificial tooth arrangement that maximizes denture stability, comfort, aesthetics, and function has occupied the dental literature for many years and still continues to do so. Of the many occlusal schemes that have been presented to the dental profession, that of lingualized occlusion has emerged as one of the more popular. The popularity of lingualized occlusion stems from the simplicity and flexibility of the concept and from its wide application to clinical practice (Parr & Ivanhoe, 1996). The registration of a repeatable correct centric jaw relation is not always possible. We don't know whether the patient will use centric relation during normal function. It is therefore useful to provide the patient with some freedom of movement around centric. lingualized occlusion provides freedom in centric. For many dentists the arrangement of artificial denture teeth into balanced occlusion is difficult and time consuming. As a result this task is most often performed by the dental technician. In the South African countryside dental laboratories are often far away. If dentists perform the arrangement of the denture teeth, time and costs can be saved. The mounting of denture teeth in lingualized occlusion is simple and fast. This will motivate dentists to arrange denture teeth themselves, with obvious benefits for both the patient and the dentist. The School of Oral Health Sciences of the University of Stellenbosch teaches this concept to its undergraduate students in order to improve the prosthetic service to the large edentulous population of South Africa.

  4. Epulis and pyogenic granuloma with occlusal interference

    Directory of Open Access Journals (Sweden)

    Widowati Witjaksono

    2005-06-01

    Full Text Available In dental clinic of Hospital University Science Malaysia (HUSM, there were cases with Localized Gingival Enlargement (LGE in the oral cavity with occlusal interference. In this study, three cases were observed. They were a 13 - year- old female with fibrous lge around 31 and 32 with occlusal interference in protrusive movement due to X bite, a 15 - year – old female with pyogenic granuloma near 11 & 21 with occlusal interference due to deep bite; and a 24 – year – old female who was eight months in pregnancy with pyogenic granuloma on the 34-35 and severe generalized pregnancy gingivitis with occlusal interference in centric occlusion and lateral movement. Clinical and histopathological diagnosis of the first case showed fibrous epulis, whereas the second and third cases disclosed pyogenic granuloma. Chronic trauma of the gingiva due to occlusal interference was assumed to be the cause of those LGE in case 1 and 2, while in case 3 poor oral hygiene and chronic trauma were assumed to be the etiologic factors.

  5. Efficacy and safety of balloon-occluded retrograde transvenous obliteration with sodium tetradecyl sulfate liquid sclerotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Park, Sang Woo; Kwon, So Young; Cheo, Won Hyeok; Cheon, Young Koog; Shim, Chan Sup; Lee, Tae Yoon; Kim, Jeong Han [Digestive Disease Center, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    To evaluate the efficacy and safety of balloon-occluded retrograde transvenous obliteration (BRTO) with sodium tetradecyl sulfate (STS) liquid sclerotherapy of gastric varices. Between February 2012 and August 2014, STS liquid sclerotherapy was performed in 17 consecutive patients (male:female = 8:9; mean age 58.6 years, range 44-86 years) with gastric varices. Retrograde venography was performed after occlusion of the gastrorenal shunt using a balloon catheter and embolization of collateral draining veins using coils or gelfoam pledgets, to evaluate the anatomy of the gastric varices. We prepared 2% liquid STS by mixing 3% STS and contrast media in a ratio of 2:1. A 2% STS solution was injected into the gastric varices until minimal filling of the afferent portal vein branch was observed (mean 19.9 mL, range 6-33 mL). Patients were followed up using computed tomography (CT) or endoscopy. Technical success was achieved in 16 of 17 patients (94.1%). The procedure failed in one patient because the shunt could not be occluded due to the large diameter of gastrorenal shunt. Complete obliteration of gastric varices was observed in 15 of 16 patients (93.8%) with follow-up CT or endoscopy. There was no rebleeding after the procedure. There was no procedure-related mortality. BRTO using STS liquid can be a safe and useful treatment option in patients with gastric varices.

  6. Relationship of Occlusal Schemes with the Occurrence of Temporomandibular Disorders

    OpenAIRE

    Dina H. Sugiaman; Laura S. Himawan; Sitti Fardaniah

    2013-01-01

    Masticatory system is a complex functional unit of the body responsible for mastication, speech, and deglutition process. Temporomandibular disorders (TMD) is used to describe all functional disturbances of the masticatory system. The etiology of TMD is multifactorial, such as occlusal disharmony and emotional stress. The relationship between occlusion and TMD has been highly debated in dentistry, one of the occlusal factors is the occlusal scheme. Occlusal schemes are defined as bilateral ca...

  7. Retinal artery occlusions in children.

    Science.gov (United States)

    Dharmasena, Aruna; Wallis, Simon

    2014-01-01

    The purpose of this study is to present a case of RAO in a 13 year old girl with a preceding history of hyperextension of the neck at her hairdressers for a long duration and use of her mobile phone handset resting it against the side of her neck presumably exerting some pressure on carotids during the same time. Materials and methods of this study was reported as case report and review of literature. A 13 year-old girl presented with the left supero-nasal scotoma due to an inferior temporal branch retinal artery occlusion (BRAO). She underwent extensive investigations and no underlying cause was discovered. She gave a history of cervical extension over a long period of time while having the hair coloured twice in the preceding week. She also mentioned that she was using her mobile phone more or less continuously during both these occasions keeping it against her neck. Given the above history it is possible that the pressure on the ipsilateral carotid arteries or the prolong neck extension may have been responsible for the formation of a platelet embolus resulting in the BRAO. In conclusion, although cerebro-vascular accidents due to 'beauty parlor stroke syndrome' (JAMA 269:2085-2086, 1993) have been reported previously it has not been reported in children to our knowledge. On the other hand, 'beauty parlor stroke syndrome' occurs due to a dissection of the vertebral arteries or due to mechanical compression of the vertebral arteries during the prolonged hyperextension of the neck. The central retinal artery originates from the internal carotid circulation and it is highly unlikely for an embolus to enter the retinal circulation from the vertebral arteries. Therefore, the authors favour the possibility that the compulsive use of a mobile phone exerting pressure on the carotid arteries for a long time may have led to the formation of an embolus and subsequent RAO in this case.

  8. Balloon-borne gamma-ray polarimetry

    CERN Document Server

    Pearce, Mark

    2011-01-01

    The physical processes postulated to explain the high-energy emission mechanisms of compact astrophysical sources often yield polarised soft gamma rays (X-rays). PoGOLite is a balloon-borne polarimeter operating in the 25-80 keV energy band. The polarisation of incident photons is reconstructed using Compton scattering and photoelectric absorption in an array of phoswich detector cells comprising plastic and BGO scintillators, surrounded by a BGO side anticoincidence shield. The polarimeter is aligned to observation targets using a custom attitude control system. The maiden balloon flight is scheduled for summer 2011 from the Esrange Space Centre with the Crab and Cygnus X-1 as the primary observational targets.

  9. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, Nicholas, E-mail: nicholas.chalmers@cmft.nhs.uk [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Walker, Paul T. [James Cook University Hospital, Department of Radiology (United Kingdom); Belli, Anna-Maria [St. George' s Healthcare NHS Trust, Department of Radiology (United Kingdom); Thorpe, Anthony P. [Aberdeen Royal Infirmary, Department of Radiology (United Kingdom); Sidhu, Paul S. [King' s College Hospital, Department of Radiology (United Kingdom); Robinson, Graham [Hull Royal Infirmary, Department of Radiology (United Kingdom); Ransbeeck, Mariella van [Johnson and Johnson Medical NV/SA, Cordis (Belgium); Fearn, Steven A. [Johnson and Johnson Medical Ltd., Cordis (United Kingdom)

    2013-04-15

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  10. Plasma levels following application of paclitaxel-coated balloon catheters in patients with stenotic or occluded femoropopliteal arteries

    Energy Technology Data Exchange (ETDEWEB)

    Freyhardt, Patrick; Kroencke, T.J.; Schreiter, N.F.; Sixt, S.; Rastan, A. [Charite Universitaetsmedizin, Berlin (Germany). Klinik fuer Strahlenheilkunde; Zeller, T.; Schwarzwaelder, U. [Herzzentrum Bad Krozingen (Germany). Abt. fuer Klinische und Interventionelle Angiologie; Stiepani, H.; Werk, M. [Martin-Luther-Krankenhaus, Berlin (Germany). Klinik fuer Radiologie und Nuklearmedizin

    2011-05-15

    Purpose: Paclitaxel-coated balloon catheters inhibit restenosis after coronary and peripheral angioplasty (PCI,PTA). The aim of this study was to investigate paclitaxel plasma levels and laboratory parameters following PTA with paclitaxel-coated balloons (PCB) in peripheral arteries. Materials and Methods: This single treatment arm, multicenter study included 14 patients with Rutherford stage 1 - 5 with occlusions of up to 5 cm or {>=} 70 % diameter stenosis of the superficial femoral or popliteal arteries (SFA, PA). PTA was performed using up to three PCB catheters. The paclitaxel plasma levels and safety laboratory parameters were determined by collecting blood samples pre-intervention, immediately post-intervention, at 0.5, 1, 2, 4, 8, 24 hours and 1 and 4 weeks post-intervention (p. i.). Vital signs were monitored to assess clinical safety. Results: PTA was performed successfully in all patients. Paclitaxel plasma levels were always below a level and duration known to cause systemic side effects. A mean peak paclitaxel plasma level (40 ng/ml) was reached immediately p. i. and decreased rapidly below detectable levels in more than half of the patients already 2 hours p. i. The paclitaxel plasma concentrations returned to values below detectable levels at 24 hours p. i. in all patients. Laboratory parameters and vital signs did not give any reason for safety concerns. No adverse events associated with balloon coating were observed. Conclusion: The results of 14 patients with peripheral arterial occlusive disease show no systemic bioavailability of paclitaxel > 24 hours after PTA with one or more PCB catheters, indicating that the PCB catheter is safe with regard to possible systemic effects. (orig.)

  11. Burn Injury Arise From Flying Balloon Toys

    OpenAIRE

    Yalcin Kulahci; Fatih Zor; Mehmet Bozkurt; Serdar Ozturk; Mustafa Sengezer

    2007-01-01

    Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloon...

  12. Double balloon enteroscopy examinations in general anesthesia

    Institute of Scientific and Technical Information of China (English)

    Laszlo; Zubek; Lena; Szabo; Peter; Laszlo; Lakatos; Janos; Papp; Janos; Gal; Gabor; Elo

    2010-01-01

    AIM:To demonstrate that the double balloon enteroscopy(DBE) can be safely performed in general anesthesia with intubation.METHODS:We performed a retrospective examination between August 2005 and November 2008 amongpatients receiving intubation narcosis due to DBE examination.The patients were grouped based on sex,age and physical status.Anesthesia records includedduration of anesthesia,quantity of medication usedand anesthesia-related complications.We determinedthe frequency of complications in the differen...

  13. MAXIS Balloon Observations of Electron Microburst Precipitation

    Science.gov (United States)

    Millan, R. M.; Hunter, A. E.; McCarthy, M. P.; Lin, R. P.; Smith, D. M.

    2003-12-01

    Quantifying and understanding losses is an integral part of understanding relativistic electron variability in the radiation belts. SAMPEX observations indicate that electron microburst precipitation is a major loss mechanism during active periods; the loss of relativistic electrons during a six hour period due to microburst precipitation was recently estimated to be comparable to the total number of trapped electrons in the outer zone (Lorentzen et al., 2001). Microburst precipitation was first observed from a balloon (Anderson and Milton, 1964), but these early measurements were only sensitive to MAXIS 2000 long duration balloon campaign. MAXIS was launched from McMurdo Station in Antarctica carrying a germanium spectrometer, a BGO scintillator and two X-ray imagers designed to measure the bremsstrahlung produced by precipitating electrons. The balloon circumnavigated the south pole in 18 days covering magnetic latitudes ranging from 58o-90o South. During the week following a moderate geomagnetic storm (with Dst reaching -91 nT), MAXIS detected a total of over 16 hours of microburst precipitation. We present high resolution spectra obtained with the MAXIS germanium spectrometer which allow us to determine the precipitating electron energy distribution. The precipitating distribution will then be compared to the trapped distribution measured by the GPS and LANL satellites. We also examine the spatial distribution of the precipitation.

  14. Long Duration Balloon Charge Controller Stack Integration

    Science.gov (United States)

    Clifford, Kyle

    NASA and the Columbia Scientific Balloon Facility are interested in updating the design of the charge controller on their long duration balloon (LDB) in order to enable the charge controllers to be directly interfaced via RS232 serial communication by a ground testing computers and the balloon's flight computer without the need to have an external electronics stack. The design involves creating a board that will interface with the existing boards in the charge controller in order to receive telemetry from and send commands to those boards, and interface with a computer through serial communication. The inputs to the board are digital status inputs indicating things like whether the photovoltaic panels are connected or disconnected; and analog inputs with information such as the battery voltage and temperature. The outputs of the board are 100ms duration command pulses that will switch relays that do things like connect the photovoltaic panels. The main component of this design is a PIC microcontroller which translates the outputs of the existing charge controller into serial data when interrogated by a ground testing or flight computer. Other components involved in the design are an AD7888 12-bit analog to digital converter, a MAX3232 serial transceiver, various other ICs, capacitors, resistors, and connectors.

  15. Report on the Brazilian Scientific Balloon Program

    Science.gov (United States)

    Braga, Joao

    2016-07-01

    We report on the recent scientific ballooning activities in Brazil, and present the plans for the next few years. Recent technological developments, especially on telecommunications and gondola attitude control systems will be reported. We also present the recent progress achieved in the development of the protoMIRAX balloon experiment. protoMIRAX is a balloon-borne hard X-ray imaging telescope under development at INPE as a pathfinder for the MIRAX (Monitor e Imageador de Raios X) satellite mission. The experiment consists essentially in a hard X-ray coded-aperture imager to operate in the 20-200 keV energy range. The detector plane is a square array of 196 10mm x 10mm x 2mm CdZnTe (CZT) planar detectors. A collimator defines a fully-coded field-of-view of 20 x 20 degrees, with 7 x 7 degrees of full sensitivity and an angular resolution of 1.7 degrees. We describe the final stages of development and testing of the front-end electronics, with charge preamplifiers, LNAs, shapers and Wilkinson-type ADCs customized for these detectors. We also show detailed Monte Carlo simulations of the flight background and the expected flight images of bright sources performed with the use of GEANT4.

  16. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  17. The use of primary stenting or balloon percutaneous transluminal coronary angioplasty for the treatment of acutely occluded saphenous vein grafts. Results from the Brazilian National Registry - CENIC

    Directory of Open Access Journals (Sweden)

    Luiz Alberto Mattos

    2001-06-01

    Full Text Available OBJECTIVE: We conducted a comparative analysis of the in-hospital outcomes of patients who underwent primary percutaneous transluminal angioplasty (PTCA or stent implantation because of an acute myocardial infarction (AMI related to an acute vein graft occlusion. METHODS: Since 1991 the Brazilian Society of Hemodynamic and Interventional Cardiology has maintained a large database (CENIC. From these, we selected all consecutive patients, who underwent primary PTCA or stenting in the first 24 hours of AMI, with the target vessel being an occluded vein graft. Immediate results and major coronary events occurring up until hospital discharge were analyzed. RESULTS: During this period, 5,932 patients underwent primary PTCA or stenting; 158 (3% of the procedures were performed because of an acute vein graft occlusion. Stenting was performed in 74 (47% patients. Patients treated with stents had a higher success rate and lower mean residual stenosis compared with those who underwent primary balloon PTCA. The incidence of reinfarction and death were similar for stenting and balloon PTCA. CONCLUSION: Primary percutaneous treatment of AMI related to acute vein graft occlusion is still an uncommon practice. Primary stenting improved luminal diameter and offered higher rates of success; however, this strategy did not reduce the in-hospital reinfarction and death rate, compared with that occurring with PTCA treatment.

  18. Clinical impact and risk stratification of balloon angioplasty for femoropopliteal disease in nitinol stenting era: Retrospective multicenter study using propensity score matching analysis

    Directory of Open Access Journals (Sweden)

    Taketsugu Tsuchiya

    2016-07-01

    Full Text Available Objective: Nitinol stenting could bring the better outcome in endovascular therapy for femoropopliteal disease. However, it might be expected that recent marked advances in both device technology and operator technique had led to improved efficacy of balloon angioplasty even in this segment. The aims of this study were to evaluate the clinical impact of balloon angioplasty for femoropopliteal disease and make risk stratification clear by propensity score matching analysis. Methods: Based on the multicenter retrospective data, 2758 patients (balloon angioplasty: 729 patients and nitinol stenting: 2029 patients, those who underwent endovascular therapy for femoropopliteal disease, were analyzed. Results: The propensity score matching procedure extracted a total of 572 cases per group, and the primary patency rate of balloon angioplasty and nitinol stenting groups after matching was significantly the same (77.2% vs 82.7% at 1 year; 62.2% vs 64.3% at 3 years; 47.8% vs 54.3% at 5 years. In multivariate Cox hazard regression analysis, significant predictors for primary patency were diabetes mellitus, regular dialysis, cilostazol use, chronic total occlusion, and intra-vascular ultra-sonography use. The strategy of balloon angioplasty was not evaluated as a significant predictor for the primary patency. After risk stratification using five items (diabetes mellitus, regular dialysis, no use of intra-vascular ultra-sonography, chronic total occlusion, and no use of cilostazol: the DDICC score, the estimated primary patency rates of each group (low, DDICC score 0–2; moderate, DDICC score 3; high risk, DDICC score 4–5 were 88.6%, 78.3%, and 63.5% at 1 year; 75.2%, 60.7%, and 39.8% at 3 years; and 66.0%, 47.1%, and 26.3% at 5 years (p < 0.0001. The primary patency rate of balloon angioplasty and nitinol stenting groups was significantly the same in each risk stratification. Conclusion: This study suggests that balloon angioplasty does

  19. Neuromuscular dentistry: Occlusal diseases and posture.

    Science.gov (United States)

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture.

  20. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  1. A survey of occlusion detection method for visual object

    Institute of Scientific and Technical Information of China (English)

    张世辉

    2016-01-01

    Occlusion problem is one of the challenging issues in vision field for a long time , and the occlu-sion phenomenon of visual object will be involved in many vision research fields .Once the occlusion occurs in a visual system , it will affect the effects of object recognition , tracking, observation and operation , so detecting occlusion autonomously should be one of the abilities for an intelligent vision system .The research on occlusion detection method for visual object has increasingly attracted atten-tions of scholars .First, the definition and classification of the occlusion problem are presented . Then, the characteristics and deficiencies of the occlusion detection methods based on the intensity image and the depth image are analyzed respectively , and the existing occlusion detection methods are compared.Finally, the problems of existing occlusion detection methods and possible research directions are pointed out .

  2. TIPS Placement via Combined Transjugular and Transhepatic Approach for Cavernous Portal Vein Occlusion: Targeted Approach

    Directory of Open Access Journals (Sweden)

    Natanel Jourabchi

    2013-01-01

    Full Text Available Purpose. We report a novel technique which aided recanalization of an occluded portal vein for transjugular intrahepatic portosystemic shunt (TIPS creation in a patient with symptomatic portal vein thrombosis with cavernous transformation. Some have previously considered cavernous transformation a contraindication to TIPS. Case Presentation. 62-year-old man with chronic pancreatitis, portal vein thrombosis, portal hypertension and recurrent variceal bleeding presents with melena and hematemesis. The patient was severely anemic, hemodynamically unstable, and required emergent portal decompression. Attempts to recanalize the main portal vein using traditional transjugular access were unsuccessful. After percutaneous transhepatic right portal vein access and navigation of a wire through the occluded main portal vein, an angioplasty balloon was inflated at the desired site of shunt takeoff. The balloon was targeted and punctured from the transjugular approach, and a wire was passed into the portal system. TIPS placement then proceeded routinely. Conclusion. Although occlusion of the portal vein increases difficulty of performing TIPS, it should not be considered an absolute contraindication. We have described a method for recanalizing an occluded portal vein using a combined transhepatic and transjugular approach for TIPS. This approach may be useful to relieve portal hypertension in patients who fail endoscopic and/or surgical therapies.

  3. Endovascular treatment of wide-necked intracranial aneurysms using of "remodeling technique" with the HyperForm balloon

    Institute of Scientific and Technical Information of China (English)

    MU Shi-qing; YANG Xin-jian; LI You-xiang; ZHANG You-ping; L(U) Ming; WU Zhong-xue

    2008-01-01

    Background Aneurysms with wide-necked or a large neck/fundus ratio, especially located on an arterial bifurcation or a small artery, are challenges for interventional neuroradiologist because of the risk of coil migration or coil protrusion into the parent vessels. Our study was designed to improve the efficacy and safety of the "remodeling technique" with the HyperForm balloon for these difficult aneurysms and was confirmed by a follow-up result. Methods From June 2004 to September 2006, forty-two patients(20 men, 22 women)with wide-necked or large neck/fundus ratio aneurysms were treated by using the"remodeling technique"with the HyperForm balloon. Results Forty wide-necked aneurysms were successfully treated with the HyperForm balloon remodeling technique with only two failed cases. Final results consisted of total occlusion in 34 cases(80.9%), subtotal in 4 (9.5%) and incomplete in 2(4.8%). One aneurysmal rupture occurred, but no clinical consequence was shown. No thromboembolic events were observed during treatment. Final angiographic follow-up time ranged from 3 to 18 months. Conclusions The "remodeling technique" with the HyperForm balloon is a very useful tool in the treatment of wide-necked or unfavorable neck/fundus ratio intracranial aneurysms-located on an arterial bifurcation or a small artery and, especially, located on the bifurcation of a large artery and a small one. In our experience, this technique provided a safe and efficient treatment for difficult aneurysms when the standard remodeling technique might have failed.

  4. Posterior circulation revascularization to manage vertebrobasilar occlusion

    Directory of Open Access Journals (Sweden)

    SHANG Yan-guo

    2012-06-01

    Full Text Available Objective To discuss the technique and effect of posterior circulation revascularization to manage vertebrobasilar occlusion. Methods Nine patients with vertebrobasilar occlusion were treated by using occipital artery-posterior inferior cerebellar artery bypass, superficial temporal artery-superior cerebellar artery bypass, superficial temporal artery-posterior cerebral artery bypass and occipital artery-vertebral artery bypass with radial artery graft. Results Intraoperative indocyanine green angiography showed all the bypass arteries were patent. Postoperative DSA or CTA showed bypass arteries patent in 8 patients, among whom seven patients got obvious improvement on MR or CT perfusion. One patient died of heart failure on the 15th day postoperative. During the follow-up of eight patients, no stroke reoccurred, four patients got back to nearly normal life. Conclusion Most of the patients with vertebrobasilar occlusion could benefit from the posterior circulation revascularization, which should be confirmed by randomized controlled clinical trials in the future.

  5. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with pe

  6. Influence of mandibular fixation method on stability of the maxillary occlusal plane after occlusal plane alteration.

    Science.gov (United States)

    Yosano, Akira; Katakura, Akira; Takaki, Takashi; Shibahara, Takahiko

    2009-05-01

    In this study, we investigated how method of mandibular fixation influenced longterm postoperative stability of the maxilla in Class III cases. In particular, we investigated change in the maxillary occlusal plane after Occlusal Plane Alteration. Therefore, we focused on change in the palatal plane to evaluate stability of the maxillary occlusal plane, as the position of the palatal plane affects the maxillary occlusal plane. This study included 16 patients diagnosed with mandibular protrusion. Alteration of the occlusal plane was achieved by clockwise rotation of the maxilla by Le Fort I osteotomy and mandibular setback was performed by bilateral sagittal split ramus osteotomy. We analyzed and examined lateral cephalometric radiographs taken at 1 month, 3 months, 6 months, and 1 year after surgery. Stability achieved by two methods of mandibular fixation was compared. In one group of patients (group S) titanium screws were used, and in the other group (group P) titanium-locking mini-plates were used. No significant displacement was recognized in group S, whereas an approximately 0.7mm upward vertical displacement was recognized in the anterior nasal spine in group P. As a result, not only the angle of the palatal plane and S-N plane, but also occlusal plane angle in group P showed a greater decrease than that in group S. The results suggest that fixing the mandible with screws yielded greater stability of the maxilla and maxillary occlusal plane than fixing the mandible with titanium plates.

  7. Preliminary results on nonparametric facial occlusion detection

    Directory of Open Access Journals (Sweden)

    Daniel LÓPEZ SÁNCHEZ

    2016-10-01

    Full Text Available The problem of face recognition has been extensively studied in the available literature, however, some aspects of this field require further research. The design and implementation of face recognition systems that can efficiently handle unconstrained conditions (e.g. pose variations, illumination, partial occlusion... is still an area under active research. This work focuses on the design of a new nonparametric occlusion detection technique. In addition, we present some preliminary results that indicate that the proposed technique might be useful to face recognition systems, allowing them to dynamically discard occluded face parts.

  8. Rationale and technique for achieving occlusal harmony.

    Science.gov (United States)

    Kimmel, Saul S

    2009-01-01

    For a patient to function normally with natural or restored dentition, the occlusal contacts should be in harmony with the musculature and the temporomandibular joint. Many times, this harmonious relationship is altered by restorative treatment, periodontal disease or tooth loss. If the adaptive capacity of the patient is less than the forces placed upon the tooth or restoration, failure in one form or another often results. This article presents a rational method the dentist can use to recognize and understand the markings made with articulating paper so that harmonious contacts can be detected and contacts that disturb occlusal harmony eliminated.

  9. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  10. Complications Related to Transcatheter Occlusion of Atrial Septal Defect with Amplatzer Septal Occluder in Children

    Institute of Scientific and Technical Information of China (English)

    Wang Shushui; Li Yufen; Zhang Zhiwei; Wang Huishen; Qian Mingyang

    2004-01-01

    Objectives To investigate the causes, theraputic and preventive methods of complications associated with transcatheter occlusion of atrial septal defect (ASD) using the Amplatzer septal occluder (ASO) in children. Methods 289 cases underwent transcatheter closure of ASD with ASO. Complications occurred in 9 cases. The complications in procedure included systemic circulatory systemic air embolism in 2, pulmonary air embolism in 1, pericardial tamponade in 1, ASO malposition requiring emergency surgical removal in 1, transient atrial extrasystoles in 1 and sizing balloon rupture in 1 case. 2 cases with postoperative complications were found in the follow-up studies. These included perforation of mitral valve and ASO partially dislodged. In this study, 5children with intraoperative complication received emergency therapy including surgical intervention, and others needed only follow-up, as the complications were transient or asymptomatic. Results There were no children death in this study. The 5 cases who received treatment were completely healing, and the others with intra - procedure complications were also had no sequela existed. Cases with mitral valve and ASO partially dislodged were still in follow-up studies, as the 2 patients having no symptoms. Conclutions Air embolism were occurred easily in atrial septal defect cases who received ASO therapy. Complications mainly caused by inappropriate operative procedure and some complications needed emergency treatments. Follow-up studies were important to cases with transcatheter occlusion therapy.

  11. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qingqiao, E-mail: 1427286069@qq.com; Huang, Qianxin, E-mail: 18705206105@163.com; Shen, Bin, E-mail: 753021357@qq.com; Sun, Jingmin, E-mail: 383937658@qq.com; Wang, Xiaolong, E-mail: 781198238@qq.com; Liu, Hongtao, E-mail: hongtao6@vip.sina.com [The Affiliated Hospital of Xuzhou Medical College, Department of Interventional Radiology and Vascular Surgery (China)

    2015-06-15

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or two hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion.

  12. Stratospheric composition from balloon based measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mencaraglia, F.; Carli, B. [Ist. per le Ricerche sulle Onde Elettromagnetiche, Firenze (Italy); Bonetti, A.; Ciarpallini, P. [Univ. di Firenze (Italy); Carlotti, M.; Lepri, G. [Univ. di Bologna (Italy); Alboni, F.; Cortesi, U.; Ridolfi, M. [Fondazione per la Metereologia Applicata, Firenze (Italy)

    1995-12-31

    Measurements of the composition of the earth`s atmosphere is of fundamental importance for the study of atmospheric chemistry and for developing models that can predict the evolution of the atmosphere itself. Here, the chemical composition of the lower stratosphere has been measured using a polarizing interferometer operating in the far infrared and submillimetric spectral region. The instrument was flown three times (in 1992, 1993 and 1994) from the NSBF balloon base (Fort Sumner, New Mexico) in coincidence with overpasses of the UARS satellite, for a total of about 50 hours of measurements. In this paper the authors report some of the results obtained from the data analysis made up to now.

  13. Double-balloon endoscopy: Who needs it?

    DEFF Research Database (Denmark)

    Hendel, J.W.; Vilmann, P.; Jensen, T.

    2008-01-01

    Objective. Double-balloon endoscopy (DBE) made the small bowel accessible to inspection and therapy in its entirety. However, DBE is a time-consuming procedure that requires a highly skilled endoscopist, several nurses and - more often than not - anesthesiological support. This makes the selectio...... within the next 12 months. Conclusions. CE can be applied as a screening procedure for DBE and allows for an approximately two-thirds reduction in the need for DBE as well as enabling a choice to be made between the oral and anal route Udgivelsesdato: 2008...

  14. Pneumothorax, music and balloons: A case series

    Directory of Open Access Journals (Sweden)

    Shiferaw Dejene

    2013-01-01

    Full Text Available We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation.

  15. Ballooning Spiders: The Case for Electrostatic Flight

    CERN Document Server

    Gorham, Peter W

    2013-01-01

    We consider general aspects of the physics underlying the flight of Gossamer spiders, also known as ballooning spiders. We show that existing observations and the physics of spider silk in the presence of the Earth's static atmospheric electric field indicate a potentially important role for electrostatic forces in the flight of Gossamer spiders. A compelling example is analyzed in detail, motivated by the observed "unaccountable rapidity" in the launching of such spiders from H.M.S. Beagle, recorded by Charles Darwin during his famous voyage.

  16. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  17. Occlusion, prosthodontic treatment, and temporomandibular disorders: a review.

    Science.gov (United States)

    Hagag, G; Yoshida, K; Miura, H

    2000-03-01

    The purpose of this article is to review the literature on the relationship between occlusal discrepancies and temporomandibular disorders (TMD) and to summarize the guidelines of treating TMD by prosthetic rehabilitation. To date, the relationship between occlusal condition and TMD has not been confirmed, although there is a current trend toward making a weak correlation between occlusal interference and TMD. Furthermore, several types of occlusal discrepancies have been considered as variable features of the norm. But unstable occlusion in the intercuspal position may cause TMD. In cases of restored dentition, the problem is probably different and iatrogenic TMD are not rare. Namely, malformed occlusal surfaces, defects in anterior guidance, occlusal curvature, and vertical dimension may lead to some TMD trouble. According to these recent concepts the treatment modalities of TMD have been changed. Conservative treatments such as counseling, behavioral modification, physical therapy, pharmacotherapy, and interocclusal appliances should be the first choice, and treatments that lead to drastic changes of occlusion are not recommended.

  18. Effect of glove occlusion on the skin barrier

    DEFF Research Database (Denmark)

    Tiedemann, Daniel; Clausen, Maja Lisa; John, Swen Malthe

    2016-01-01

    of this study is to review the literature on the effects of glove occlusion on skin barrier function. The PubMed database was searched up to 1 February 2015 for articles on the association between glove occlusion and skin barrier function, including human studies only and in English. Only experimental studies...... including assessment of the skin barrier function were included in the data analysis. Thirteen articles were identified, 8 with focus on occlusion alone, 7 with focus on occlusion in combination with irritant exposure (some overlapping), and 2 field studies. In conclusion, data from the literature showed...... that the negative effect of occlusion in itself is limited, and that only extensive and long-term occlusion will cause barrier impairment. However, studies investigating combined effect of occlusion and exposure to soaps/detergents indicate that occlusion significantly enhances the skin barrier damage caused...

  19. Occlusal Caries: Biological Approach for Its Diagnosis and Management

    DEFF Research Database (Denmark)

    Christina Carvalho, Joana; Dige, Irene; Machiulskiene, Vita

    2016-01-01

    process on occlusal surfaces. In addition, it considers the whole spectrum of the caries process on occlusal surfaces, ranging from the molecular ecology of occlusal biofilms to the management of deep occlusal caries lesions. Studies using molecular methods with focus on biofilms in relation to occlusal...... caries should explore the relationship between the function and the structural composition of these biofilms to understand the role of occlusal biofilms in caries development. State-of-the-art measures to evaluate risk for occlusal caries lesion activity, caries incidence, and progression should include...... the assessment of the occlusal biofilm and the stage of tooth eruption. Careful clinical examination of non-cavitated lesions, including assessment of the lesion activity status, remains the major tool to determine the immediate treatment need and to follow on the non-operative treatment outcome. Even medium...

  20. 21 CFR 870.1350 - Catheter balloon repair kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the... effect the repair or replacement. (b) Classification. Class III (premarket approval). (c) Date PMA...

  1. Reversible transient apical ballooning syndrome with coronary lesions

    Institute of Scientific and Technical Information of China (English)

    Yunshan Cao; Min Zhang; Xiang Li; Ping Xie; Lynn Cronin

    2009-01-01

    Transient apical ballooning syndrome(Tako-Tsubo syndrome or ampulla cardiomyopathy) occurs predominantly in women over 60 years of age with a history of recent physical or psychological stress. We present a case of a male patient with reversible transient apical ballooning syndrome with significant coronary lesions and other ECG changes that did not explain the clinical symptoms.

  2. Virtual occlusal definition for orthognathic surgery.

    Science.gov (United States)

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate.

  3. Crossing Total Occlusions: Navigating Towards Recanalization

    NARCIS (Netherlands)

    Sakes, A.; Regar, E.; Dankelman, J; Breedveld, P.

    2016-01-01

    Chronic total occlusions (CTOs) represent the “last frontier” of percutaneous interventions. The main technical challenges lies in crossing the guidewire into the distal true lumen, which is primarily due to three problems: device buckling during initial puncture, inadequate visualization, and the i

  4. Crossing Total Occlusions: Navigating Towards Recanalization

    NARCIS (Netherlands)

    A. Sakes (Aimée); E.S. Regar (Eveline); J. Dankelman (Jenny); P. Breedveld (Paul)

    2016-01-01

    textabstractChronic total occlusions (CTOs) represent the “last frontier” of percutaneous interventions. The main technical challenges lies in crossing the guidewire into the distal true lumen, which is primarily due to three problems: device buckling during initial puncture, inadequate visualizatio

  5. Arterial occlusion precipitated by cisplatinbased chemotherapy

    OpenAIRE

    2010-01-01

    Cisplatin-based therapy is curative in testicular cancer. Adverse effects of cisplatin-based chemotherapy include dose-dependent myelosuppression, nephrotoxicity, neurotoxicity, and ototoxicity. By contrast, chemotherapy-associated vascular complications are unpredictable. Few incidents of digital gangrene with cisplatin have been reported. Here, we present a patient who developed arterial occlusion leading to gangrene of the toe after cisplatinbased chemotherapy.

  6. Clinical Practice Guidelines for intestinal occlusion.

    Directory of Open Access Journals (Sweden)

    Rudis Miguel Monzón Rodríguez

    2009-03-01

    Full Text Available Clinical Practice Guidelines for intestinal occlusion. This document includes the main aspects related with classification, physiopathology, clinical diagnosis, complementary examinations and therapy aimed at the post-operatory treatment. It includes assessment guidelines focused on the most important aspects to be accomplished.

  7. Virtual occlusion in planning orthognathic surgical procedures.

    NARCIS (Netherlands)

    Nadjmi, N.; Mollemans, W.; Daelemans, A.; Hemelen, G. Van; Schutyser, F.A.C.; Berge, S.J.

    2010-01-01

    Accurate preoperative planning is mandatory for orthognathic surgery. One of the most important aims of this planning process is obtaining good postoperative dental occlusion. Recently, 3D image-based planning systems have been introduced that enable a surgeon to define different osteotomy planes pr

  8. Cilioretinal artery occlusion following intranasal cocaine insufflations

    Directory of Open Access Journals (Sweden)

    Balaji Kannan

    2011-01-01

    Full Text Available Cocaine is used to produce a euphoric effect by abusers, who may be unaware of the devastating systemic and ocular side effects of this drug. We describe the first known case of cilioretinal artery occlusion after intranasal cocaine abuse.

  9. Class II malocclusion occlusal severity description

    Directory of Open Access Journals (Sweden)

    Guilherme Janson

    2010-08-01

    Full Text Available OBJECTIVES: It is well known that the efficacy and the efficiency of a Class II malocclusion treatment are aspects closely related to the severity of the dental anteroposterior discrepancy. Even though, sample selection based on cephalometric variables without considering the severity of the occlusal anteroposterior discrepancy is still common in current papers. In some of them, when occlusal parameters are chosen, the severity is often neglected. The purpose of this study is to verify the importance given to the classification of Class II malocclusion, based on the criteria used for sample selection in a great number of papers published in the orthodontic journal with the highest impact factor. MATERIAL AND METHODS: A search was performed in PubMed database for full-text research papers referencing Class II malocclusion in the history of the American Journal of Orthodontics and Dentofacial Orthopedics (AJO-DO. RESULTS: A total of 359 papers were retrieved, among which only 72 (20.06% papers described the occlusal severity of the Class II malocclusion sample. In the other 287 (79.94% papers that did not specify the anteroposterior discrepancy severity, description was considered to be crucial in 159 (55.40% of them. CONCLUSIONS: Omission in describing the occlusal severity demands a cautious interpretation of 44.29% of the papers retrieved in this study.

  10. Longitudinal occlusal changes from primary to permanent dentition in children with normal primary occlusion.

    Science.gov (United States)

    Legovic, M; Mady, L

    1999-06-01

    This purpose of this research was to examine the stability of normal occlusion during the transition from primary to permanent dentition. The sample consisted of 128 children (83 boys and 45 girls) 4.5 to 5.5 years old with normal occlusion in the primary dentition. The subjects were reexamined at 12.5 to 13.5 years. None had received orthodontic treatment. Although all the subjects had normal occlusion in the primary dentition, 72.7% (73.5% boys and 71.1% girls) had developed anomalies following eruption of the permanent teeth. These anomalies included crowding, Class II Division 1 or Class II Division 2 malocclusion, mesial occlusion complex, lateral crossbite, anterior crossbite, premature tooth loss, openbite or other anomalies.

  11. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  12. A New Paradigm in Space Based Experiments Using Rubber Balloons

    CERN Document Server

    Chakrabarti, Sandip K; Palit, Sourav; Chakraborty, Subhankar; Mondal, Sushanta; Bhattacharyya, Arnab; Middya, Susanta; Chakrabarti, Sonali

    2013-01-01

    Indian Centre for Space Physics is engaged in long duration balloon borne experiments with typical payloads less than ~ 3kg. Low cost rubber balloons are used. In a double balloon system, the booster balloon lifts the orbiter balloon to its cruising altitude where data is taken for a long time. Here we present results of muon detections and recent solar activities, including the light curves and flare spectra in the 20-100keV range. We not only show that we have successfully obtained several flares and there spectra at different altitudes, we also found that the high energy X-ray flux of strong flares at altitudes of 10-13 km (the flight altitude of commercial planes) could be more than the contribution due to cosmic rays.

  13. An overview of instrumentation capabilities for Scientific ballooning in India

    Science.gov (United States)

    Devarajan, Anand; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Bangaru, Kapardhi; Trivedi, Dharmesh; Rodi, Ashish; Ojha, Devendra; Koli, Santosh

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) in India, launches scientific balloons for research in the field of astronomy, astrobiology and atmospheric sciences. TIFR-BF not only has the capability to design, fabricate and launch zero-pressure balloons, but also provide operational and engineering support for launching them. The Control Instrumentation Group (CIG) at the balloon facility handles all electronics related to telemetry, telecommand, tracking, real-time data display, data storage, air-safety and payload recovery. In the recent past, it has designed and developed customized electronics and payload orientation mechanism to meet specific experimental objectives. Small, inexpensive and rugged industrial grade radio data modems were successfully deployed in balloon flights for low bit rate data and image telemetry. This paper will provide an overview and in-flight performance of some of the recent developments in instrumentation and electronics systems. Our plans for future upgradations will also be discussed.

  14. Global kinetic ballooning mode simulations in BOUT++

    Science.gov (United States)

    Ma, C. H.; Xu, X. Q.

    2017-01-01

    We report on simulation results of a 3+1 gyro-Landau-fluid (GLF) model in BOUT++ framework, which contributes to increasing the physics understanding of the edge turbulence. We find that there is no second stability region of kinetic ballooning modes (KBM) in the concentric circular geometry. The first unstable β of KBM decreases below the ideal ballooning mode threshold with increasing {ηi} . In order to study the KBM in the real tokamak equilibrium, we find that the approximation of shifted circular geometry (β \\ll {{\\varepsilon}2} ) is not valid for a high β global equilibrium near the second stability region of KBM. Thus we generate a series of real equilibria from a global equilibrium solver CORSICA, including both Shafranov shift and elongation effects, but not including bootstrap current. In these real equilibria, the second stability region of KBM are observed in our global linear simulations. The most unstable mode for different β are the same while the mode number spectrum near the second stability region is wider than the case near the first stability region. The nonlinear simulations show that the energy loss of an ELM keeps increasing with β, because the linear drive of the turbulence remains strong for the case near the second stability region during profile evolution.

  15. A constitutive equation for stratospheric balloon materials

    Science.gov (United States)

    Rand, J.; Sterling, J.

    The selection of a suitable material for use as a reliable stratospheric balloon gas barrier and structural component is based on a variety of desired properties. In order to achieve the required combination of weight per unit area, helium permeation, strength, flexibility and toughness at low temperatures, low density polyethylene has been used for the last half century. During the last decade, linear low density polyethylene (LLDPE) has been found to have even better properties for this application. Thin films extruded from this type resin have been found to have time dependent properties which should be understood in order to make an intelligent analysis of the balloon. This paper describes the current effort to characterize a 38 micron coextrusion of LLDPE as a nonlinearly viscoelastic material. The resulting constitutive equation may be used to accurately describe the time dependent creep and/or relaxation of this film when subjected to a biaxial state of stress. Recent laboratory data have been used to modify an existing model of LLDPE to account for differences caused by the coextrusion process. The new model will facilitate structure design optimization and reliability assessment, and may further be utilized as a predictive tool to benefit in-flight operations. Unfortunately, current structural analysis techniques based on linear elastic properties will predict stresses in excess of those which actually exist. An example will be presented which demonstrates the magnitude of this error when nonlinear behavior is ignored.

  16. EUSO-Balloon: The first flight

    Science.gov (United States)

    Scotti, Valentina; Osteria, Giuseppe

    2016-07-01

    EUSO-Balloon is a pathfinder mission for JEM-EUSO, the near-UV telescope proposed to be installed on board the International Space Station (ISS). The main objective of this pathfinder mission is to perform a full scale end-to-end test of all the key technologies of JEM-EUSO detectors and to measure the UV background. The JEM-EUSO instrument consists of UV telescope designed to focus the signal of the UV tracks generated by Extreme Energy Cosmic Rays propagating in Earth's atmosphere, onto a finely pixelized UV camera. The EUSO-Balloon instrument, smaller than the one designed for the ISS, was launched on August 2014 from Timmins (Ontario, Canada). The flight lasted about five hours and the instrument reached a float altitude of about 40 km. From this altitude the telescope registered, at a rate of 400 000 frames/s, the nightglow background on forests, lakes and clouds, as well as city lights and artificial air showers tracks generated by means of a laser installed on an helicopter flying inside its field of view. In this contribution we will describe the instrument and its performance during the first flight.

  17. EUSO-Balloon: The first flight

    Energy Technology Data Exchange (ETDEWEB)

    Scotti, Valentina, E-mail: scottiv@na.infn.it; Osteria, Giuseppe

    2016-07-11

    EUSO-Balloon is a pathfinder mission for JEM-EUSO, the near-UV telescope proposed to be installed on board the International Space Station (ISS). The main objective of this pathfinder mission is to perform a full scale end-to-end test of all the key technologies of JEM-EUSO detectors and to measure the UV background. The JEM-EUSO instrument consists of UV telescope designed to focus the signal of the UV tracks generated by Extreme Energy Cosmic Rays propagating in Earth's atmosphere, onto a finely pixelized UV camera. The EUSO-Balloon instrument, smaller than the one designed for the ISS, was launched on August 2014 from Timmins (Ontario, Canada). The flight lasted about five hours and the instrument reached a float altitude of about 40 km. From this altitude the telescope registered, at a rate of 400 000 frames/s, the nightglow background on forests, lakes and clouds, as well as city lights and artificial air showers tracks generated by means of a laser installed on an helicopter flying inside its field of view. In this contribution we will describe the instrument and its performance during the first flight.

  18. Budd-Chiari syndrome: A case with a combination of hepatic vein and superior vena cava occlusion

    Institute of Scientific and Technical Information of China (English)

    Yoshio Araki; Chikara Sakaguchi; Izumi Ishizuka; Masaya Sasaki; Tomoyuki Tsujikawa; Shigeki Koyama; Akira Furukawa; Yoshihide Fujiyama

    2005-01-01

    We here report a recent, rare case of Budd-Chiari syndrome, associated with a combination of hepatic vein and superior vena cava occlusion. A young female, who had been ingood health, was admitted to our hospital because of massive ascites. The patient had used no oral contraceptives. Tests for coagulation disorders, hematological disorders, and antiphospholipid syndrome were all negative. BuddChiari syndrome was diagnosed by radiographic examination. The patient was suffering from a combination of hepatic vein and superior vena cava occlusion. In particular, the venous flow returned from the liver mainly through a right accessory hepatic vein, and stenosis was recognized at the orifice of this collateral vein into the vena cava.Subsequently, the patient underwent percutaneous balloon dilatation therapy for this stenosis. After this treatment, the massive ascites was gradually reduced, and she was discharged from our hospital. It has now been one year since discharge, and the patient has been doing well. If deteriorating liver function or intractable ascites occur again, a liver transplantation may be anticipated. This is the first case report of Budd-Chiari syndrome associated with a superior vena cava occlusion.

  19. An appraisal on increasing the occlusal vertical dimension in full occlusal rehabilitation and its outcome.

    Science.gov (United States)

    Gopi Chander, N; Venkat, R

    2011-06-01

    Increasing the occlusal vertical dimension for gaining sufficient restoration space in the management of severely worn dentition is being practiced. This contentious belief has lead to challenging thoughts regarding its effects on the Odonto-stomatognathic system. There are basic uncertainties and existing erroneous thoughts regarding the perception of increasing the occlusal vertical dimension. This manuscript will review the bite raising concepts and its outcome on the stomatognathic system.

  20. An Appraisal on Increasing the Occlusal Vertical Dimension in Full Occlusal Rehabilitation and its Outcome

    OpenAIRE

    2011-01-01

    Increasing the occlusal vertical dimension for gaining sufficient restoration space in the management of severely worn dentition is being practiced. This contentious belief has lead to challenging thoughts regarding its effects on the Odonto-stomatognathic system. There are basic uncertainties and existing erroneous thoughts regarding the perception of increasing the occlusal vertical dimension. This manuscript will review the bite raising concepts and its outcome on the stomatognathic system.

  1. Occlusion as a causative factor in TMD. Scientific basis to occlusal therapy.

    Science.gov (United States)

    Becker, I M

    1995-11-01

    There appears to be a pendulum swing toward large epidemiologic studies questioning the role of occlusion in dentistry. This article clearly demonstrates that significant scientific evidence exists on the side of occlusal causative factors. Clinicians need this current information to base practical decisions of treatment relative to both patients and those requiring restorative procedures. It further correctly clarifies that stress-related issues have an important role, along with other host-susceptibility altering factors.

  2. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    1991-01-01

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  3. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  4. Subintimal TRAnscatheter Withdrawal (STRAW) of hematomas compressing the distal true lumen: a novel technique to facilitate distal reentry during recanalization of chronic total occlusion (CTO).

    Science.gov (United States)

    Smith, Elliot J; Di Mario, Carlo; Spratt, James C; Hanratty, Colm G; de Silva, Ranil; Lindsay, Alistair C; Grantham, J Aaron

    2015-01-01

    The development of a large hematoma impairing visualization of the distal true lumen is a recognized complication of antegrade recanalization of chronic total occlusions, often forcing the operator to abort the procedure or switch to a retrograde approach. We describe a novel technique utilizing an over-the-wire balloon inflated in the proximal occluded vessel to block inflow and allow aspiration of the blood from the subintimal space. This decompressed the true lumen, restored distal visualization, and allowed successful reentry using a dedicated technology. Utilization of this novel technique may rescue antegrade recanalization attempts complicated by large subintimal hematomas.

  5. Awake extracorporeal membrane oxygenation (ECMO) as bridge to recovery after left main coronary artery occlusion: a promising concept of haemodynamic support in cardiogenic shock.

    Science.gov (United States)

    Alozie, Anthony; Kische, Stephan; Birken, Thomas; Kaminski, Alexander; Westphal, Bernd; Nöldge-Schomburg, Gabriele; Ince, Hüseyin; Steinhoff, Gustav

    2014-10-01

    Cardiogenic shock following acute myocardial infarction is associated with high mortality rate. Different management concepts including fluid management, inotropic support, intra aortic balloon counterpulsation (IABP) and extracorporeal membrane oxygenation (ECMO) mainly in mechanically ventilated patients have been used as cornerstones of management. However, success rates have been disappointing. Few reports suggested that ECMO when performed under circumvention of mechanical ventilation, may offer some survival benefits. We herein present our experience with the use of veno-arterial ECMO as bridge to recovery in an awake and spontaneously breathing patient after left main coronary artery occlusion complicated by cardiogenic shock.

  6. Occlusion Handling in Videos Object Tracking: A Survey

    Science.gov (United States)

    Lee, B. Y.; Liew, L. H.; Cheah, W. S.; Wang, Y. C.

    2014-02-01

    Object tracking in video has been an active research since for decades. This interest is motivated by numerous applications, such as surveillance, human-computer interaction, and sports event monitoring. Many challenges related to tracking objects still remain, this can arise due to abrupt object motion, changing appearance patterns of objects and the scene, non-rigid object structures and most significant are occlusion of tracked object be it object-to-object or object-to-scene occlusions. Generally, occlusion in object tracking occur under three situations: self-occlusion, inter-object occlusion by background scene structure. Self-occlusion occurs most frequently while tracking articulated objects when one part of the object occludes another. Inter-object occlusion occurs when two objects being tracked occlude each other whereas occlusion by the background occurs when a structure in the background occludes the tracked objects. Typically, tracking methods handle occlusion by modelling the object motion using linear and non-linear dynamic models. The derived models will be used to continuously predicting the object location when a tracked object is occluded until the object reappears. Example of these method are Kalman filtering and Particle filtering trackers. Researchers have also utilised other features to resolved occlusion, for example, silhouette projections, colour histogram and optical flow. We will present some result from a previously conducted experiment when tracking single object using Kalman filter, Particle filter and Mean Shift trackers under various occlusion situation in this paper. We will also review various other occlusion handling methods that involved using multiple cameras. In a nutshell, the goal of this paper is to discuss in detail the problem of occlusion in object tracking and review the state of the art occlusion handling methods, classify them into different categories, and identify new trends. Moreover, we discuss the important

  7. Design and Calibrations of the Protomirax Balloon Telescope and the Brazilian Scientific Balloon Program

    Science.gov (United States)

    Braga, Joao; D'Amico, Flavio; Avila, Manuel

    2012-07-01

    In this presentation we report on the recent scientific ballooning activities in Brazil, including important international collaborations, and present our plan for the next few years. We also present the recent progress achieved in the design of the detector system of the protoMIRAX balloon experiment and report on the scientific balloon activities in Brazil. protoMIRAX is a balloon-borne X-ray imaging telescope under development at INPE as a pathfinder for the MIRAX (Monitor e Imageador de Raios X) satellite mission. The experiment consists essentially in an X-ray (30-200 keV) coded-aperture imager which employs a square array of 196 10mm x 10mm x 2mm CdZnTe (CZT) planar detectors made by eV Products in the USA. A collimator defines a fully-coded field-of-view of 20o x 20o, with 4o x 4o of full sensitivity. The final angular resolution will depend on the mask pattern used. In this paper we describe the design and development of the detector plane, including the front-end electronics. Preamplifiers and shaping amplifiers, customized for these detectors, were designed and built at INPE. Laboratory spectral measurements show an energy resolution of 12.0% at 60 keV, of which 10.6% is due to intrinsic electronics noise measured with a pulser at similar pulse height levels. We present spectral results obtained in the laboratory as well as initial calibration results of the acquisition system designed to get positions and energies in the detector plane. We show simulations of the coded-aperture images with different mask designs and iterative reconstruction methods.

  8. Balloon observations of spatial coherence in the Global Circuit

    Science.gov (United States)

    Holzworth, R. H.; Polar Patrol Balloon Team

    The first campaign of the Polar Patrol Balloon (PPB) experiment (1st-PPB) was carried out at Syowa Station in Antarctica during 1990-1991 and 1992-1993. Based on the results of the 1st-PPB experiment, the next campaign (2nd-PPB) was carried out in the austral summer of 2002-2003. This paper will present the global circuit results from the 2nd-PPB experiment. In that experiment, three balloons were launched for the purpose of upper atmosphere physics observation (3 balloons). Payloads of these 3 flights were identical with each other, and were launched as close together in time as allowed by weather conditions to constitute a cluster of balloons during their flights. Such a "Balloon Cluster" is suitable to observe temporal evolution and spatial distribution of phenomena in the ionospheric regions and boundaries that the balloons traversed during their circumpolar trajectory. More than 20 days of simultaneous fair weather 3-axis electric field and stratospheric conductivity data were obtained at geomagnetic latitudes ranging from sub-auroral to the polar cap. Balloon separation varied from ˜ 60 to ˜ 500 km. This paper will present the global circuit observations with emphasis on the times of apparent spatial variation in the vertical fair weather field.

  9. Concepts of occlusion in prosthodontics: A literature review, part I

    Science.gov (United States)

    Rangarajan, V.; Gajapathi, B.; Yogesh, P. B.; Ibrahim, M. Mohamed; Kumar, R. Ganesh; Karthik, Prasanna

    2015-01-01

    Occlusion and its relationship to the function of the stomatognathic system have been widely studied in dentistry since many decades. This series of articles describe about occlusion in the complete denture, fixed partial denture, and implants. Part I and II of this articles series describe concepts and philosophies of occlusion in complete denture. So far, available research has not concluded a superior tooth form or occlusal scheme to satisfy the requirements of completely edentulous patients with respect to comfort, mastication, phonetics, and esthetics. Since then, several balanced and nonbalanced articulation concepts were proposed in the literature. A balanced articulation appears to be most appropriate because of tooth contacts observed during nonfunctional activities of patients. This article discusses about evolution of different concepts of occlusion and occlusal schemes in complete denture occlusion. PMID:26929513

  10. Geodesic Acoustic Propagation and Ballooning Mode Formalism

    Science.gov (United States)

    Li, M. B.; Diamond, P. H.; Young, G. G.; Arakawa, M.

    2005-10-01

    Relevance of ballooning formalism (BMF) in nonlinear interaction of toroidal electromagnetic drift waves in the presence of zonal flows and Geodesic Acoustic Oscillation (GAO) is critically examined from a physical argument of radial propagation of wave packets. To achieve the quasi-translational invariance of poloidal harmonics which is necessary for the BMF, the geodesic curvature induced transfer [1] of fluctuation energy in radial direction should occur faster than the time scale of physical interest. Of course, this does not happen necessarily in drift-Alfven (DALF) turbulence simulations [2]. This observation casts considerable doubts on the applicability of various codes based on the BMF concept to nonlinear electromagnetic problems. [1] B. Scott, Phys. Letters A 320 (2003) 53. [2] B. Scott, New J. Phys 7 (2005) 92.

  11. The Norwegian Sounding Rocket and Balloon Program

    Science.gov (United States)

    Skatteboe, Rolf

    2001-08-01

    The status and recent developments of the Norwegian Sounding Rocket and Balloon Program are presented with focus on national activities and recent achievements. The main part of the Norwegian program is sounding rocket launches conducted by Andøya Rocket Range from the launch facilities on Andøya and at Svalbard. For the majority of the programs, the scientific goal is investigation of processes in the middle and upper atmosphere. The in situ measurements are supplemented by a large number of ground-based support instruments located at the ALOMAR Observatory. The ongoing and planned projects are described and the highlights of the latest completed projects are given. The scientific program for the period 2001-2003 will be reviewed. Several new programs have been started to improve the services available to the international science comunity. The Hotel Payload project and MiniDusty are important examples that will be introduced in the paper. Available space related infrastructure is summarized.

  12. Intragastric balloon: ethics, medical need and cosmetics.

    Science.gov (United States)

    Kotzampassi, Katerina; Shrewsbury, Anne D

    2008-01-01

    The development of the intragastic balloon as a safe, noninvasive, alternative method to weight reduction raises all the ethical questions routinely faced by practitioners of other forms of cosmetic surgery. In the case of the morbidly, severely or merely obese, the surgeon is faced with a medical decision in a situation defined by medical parameters. The case of the overweight or normal may, however, create an ethical dilemma in which the doctor is forced to make decisions of a nonmedical nature, for which his training has not prepared him, and relating essentially to his personal attitudes and moral beliefs, culture and the recognition that 'if I don't, somebody else--possibly less competent--will'.

  13. RTSAH Traversal Order for Occlusion Rays

    KAUST Repository

    Ize, Thiago

    2011-04-01

    We accelerate the finding of occluders in tree based acceleration structures, such as a packetized BVH and a single ray kd-tree, by deriving the ray termination surface area heuristic (RTSAH) cost model for traversing an occlusion ray through a tree and then using the RTSAH to determine which child node a ray should traverse first instead of the traditional choice of traversing the near node before the far node. We further extend RTSAH to handle materials that attenuate light instead of fully occluding it, so that we can avoid superfluous intersections with partially transparent objects. For scenes with high occlusion, we substantially lower the number of traversal steps and intersection tests and achieve up to 2× speedups. © 2010 The Author(s).

  14. Handling Occlusions for Robust Augmented Reality Systems

    Directory of Open Access Journals (Sweden)

    Madjid Maidi

    2010-01-01

    Full Text Available In Augmented Reality applications, the human perception is enhanced with computer-generated graphics. These graphics must be exactly registered to real objects in the scene and this requires an effective Augmented Reality system to track the user's viewpoint. In this paper, a robust tracking algorithm based on coded fiducials is presented. Square targets are identified and pose parameters are computed using a hybrid approach based on a direct method combined with the Kalman filter. An important factor for providing a robust Augmented Reality system is the correct handling of targets occlusions by real scene elements. To overcome tracking failure due to occlusions, we extend our method using an optical flow approach to track visible points and maintain virtual graphics overlaying when targets are not identified. Our proposed real-time algorithm is tested with different camera viewpoints under various image conditions and shows to be accurate and robust.

  15. Handling Occlusions for Robust Augmented Reality Systems

    Directory of Open Access Journals (Sweden)

    Maidi Madjid

    2010-01-01

    Full Text Available Abstract In Augmented Reality applications, the human perception is enhanced with computer-generated graphics. These graphics must be exactly registered to real objects in the scene and this requires an effective Augmented Reality system to track the user's viewpoint. In this paper, a robust tracking algorithm based on coded fiducials is presented. Square targets are identified and pose parameters are computed using a hybrid approach based on a direct method combined with the Kalman filter. An important factor for providing a robust Augmented Reality system is the correct handling of targets occlusions by real scene elements. To overcome tracking failure due to occlusions, we extend our method using an optical flow approach to track visible points and maintain virtual graphics overlaying when targets are not identified. Our proposed real-time algorithm is tested with different camera viewpoints under various image conditions and shows to be accurate and robust.

  16. Photoacoustic removal of occlusions from blood vessels

    Science.gov (United States)

    Visuri, Steven R.; Da Silva, Luiz B.; Celliers, Peter M.; London, Richard A.; Maitland, IV, Duncan J.; Esch, Victor C.

    2002-01-01

    Partial or total occlusions of fluid passages within the human body are removed by positioning an array of optical fibers in the passage and directing treatment radiation pulses along the fibers, one at a time, to generate a shock wave and hydrodynamics flows that strike and emulsify the occlusions. A preferred application is the removal of blood clots (thrombin and embolic) from small cerebral vessels to reverse the effects of an ischemic stroke. The operating parameters and techniques are chosen to minimize the amount of heating of the fragile cerebral vessel walls occurring during this photo acoustic treatment. One such technique is the optical monitoring of the existence of hydrodynamics flow generating vapor bubbles when they are expected to occur and stopping the heat generating pulses propagated along an optical fiber that is not generating such bubbles.

  17. Nontraumatic vascular emergencies: imaging and intervention in acute venous occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Haage, Patrick; Schmitz-Rode, Thomas [Department of Diagnostic Radiology, University of Technology Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Krings, Timo [Department of Neuroradiology, University of Technology Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany)

    2002-11-01

    Risk factors for acute venous occlusion range from prolonged immobilization to hypercoagulability syndromes, trauma, and malignancy. The aim of this review article is to illustrate the different imaging options for the diagnosis of acute venous occlusion and to assess the value of interventional strategies for venous thrombosis treatment in an emergency setting. First, diagnosis and treatment of the most common form of venous occlusion, at the level of the lower extremities, is presented, followed by pelvic vein and inferior vena cava occlusion, mesenteric venous thrombosis, upper extremity occlusion, acute cerebral vein thrombosis, and finally acute venous occlusion of hemodialysis access. In acute venous occlusion of the lower extremity phlebography is still the reference gold standard. Presently, duplex ultrasound with manual compression is the most sensitive and specific noninvasive test. Limitations of ultrasonography include isolated distal calf vein occlusion, obesity, and patients with lower extremity edema. If sonography is nondiagnostic, venography should be considered. Magnetic resonance venography can differentiate an acute occlusion from chronic thrombus, but because of its high cost and limited availability, it is not yet used for the routine diagnosis of lower extremity venous occlusion only. Regarding interventional treatment, catheter-directed thrombolysis can be applied to dissolve thrombus in charily selected patients with symptomatic occlusion and no contraindications to therapy. Acute occlusion of the pelvic veins and the inferior vena cava, often due to extension from the femoropopliteal system, represents a major risk for pulmonary embolism. Color flow Doppler imaging is often limited owing to obesity and bowel gas. Venography has long been considered the gold standard for identifying proximal venous occlusion. Both CT scanning and MR imaging, however, can even more accurately diagnose acute pelvis vein or inferior vena cava occlusion. MRI is

  18. Results of the first EUSO-Balloon flight

    Science.gov (United States)

    Miyamoto, H.; Bertaina, M.; JEM-EUSO Collaboration

    2016-05-01

    EUSO-Balloon, a balloon-borne diffractive fluorescence telescope, was launched by the French Space Agency ONES from the Timmins base in Ontario (Canada) on August 25th in 2014. After reaching the floating altitude of about 38 km, EUSO-Balloon imaged the UV background for more than 5 hours before descending to ground using the key technologies of JEM-EUSO. A detailed and precise measurement of the UV background in different atmospheric and ground conditions was achieved. The instrument proved the capability of detecting Extensive Air Showers (EAS) by observing laser tracks with similar characteristics. This contribution will summarise the first results obtained concerning all the topics described above.

  19. Balloon dilation of congenital supravalvular pulmonic stenosis in a dog

    Science.gov (United States)

    Treseder, Julia R.

    2017-01-01

    Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a case of supravalvular pulmonic stenosis diagnosed echocardiographically and angiographically in which a significant reduction in pressure gradient was achieved with balloon dilation alone is presented. PMID:27297421

  20. An investigation of electrostatically deposited radionuclides on latex balloons

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.; Caly, A., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2012-07-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  1. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  2. Strategies for Successful Percutaneous Revascularization of Chronic Total Occlusion of the Femoropopliteal Arteries When the Antegrade Passage of a Guide Wire Fails

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hui Jin; Park, Sang Woo; Chang, So Il; Jeon, Hae Jeong; Park, Jeong Hee [Konkuk University Hospital, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2012-07-15

    To evaluate the efficacy of various strategies for revascularization of chronic total occlusion of femoropopliteal arteries when the guide wire does not pass in an anterograde direction. Twenty-four patients with totally occluded femoropopliteal arteries (mean occlusion length 13.75 cm; range, 6-22 cm) were treated by using a retrograde approach and two novel catheters. After successful recanalization or reentry, balloon angioplasty followed by stent placement was performed to complete the revascularization. In 16 cases in which to cross the occlusion via intraluminal or subintimal route was failed, we used Frontrunner catheters in five cases and Outback catheters in 11 cases. In eight cases in which to reenter after subintimal passage of the guide wire was failed, we used Outback catheters. Successful recanalization was achieved intraluminally or subintimally in all cases. One perforation occurred during subintimal passage of the guide wire that was controlled by recanalization of another subintimal tract. There were no cases of distal thromboembolism or other complications. A retrograde approach and using the Frontrunner and Outback catheters are safe and effective for successful revascularization of chronic total occlusion of femoropopliteal arteries. In particular, they are useful when the initial antegrade attempts at recanalization have failed.

  3. Dental Occlusion and Ophthalmology: A Literature Review

    Science.gov (United States)

    Marchili, Nicola; Ortu, Eleonora; Pietropaoli, Davide; Cattaneo, Ruggero; Monaco, Annalisa

    2016-01-01

    Stomatognathic system is strictly correlated to other anatomical regions; many studies investigated relationship between temporomandibular joint and posture, several articles describe cranio-facial pain from dental causes, such as trigger points. Until now less interest has been given to connections between dental occlusion and ophthalmology, even if they are important and involving. Clinical experience in dental practice claims that mandibular latero-deviation is connected both to eye dominance and to defects of ocular convergence. The trigeminal nerve is the largest and most complex of the twelve cranial nerves. The trigeminal system represents the connection between somitic structures and those derived from the branchial arches, collecting the proprioception from both somitic structures and oculomotor muscles. The intermedius nucleus of the medulla is a small perihypoglossal brainstem nucleus, which acts to integrate information from the head and neck and relays it on to the nucleus of the solitary tract where autonomic responses are generated. This intriguing neurophysiological web led our research group to investigate anatomical and functional associations between dental occlusion and vision. In conclusion, nervous system and functional pathways strictly connect vision and dental occlusion, and in the future both dentists and oculists should be more and more aware of this correlation for a better diagnosis and therapy. PMID:27733873

  4. Laser photocoagulation for retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    K. A. Mirzabekova

    2015-03-01

    Full Text Available Retinal vein occlusion (RVO is one of the leading causes of permanent vision loss. In adults, central retinal vein occlusion (CRVO occurs in 1.8% while branch retinal vein occlusion (BRVO occurs in 0.2%. Treatment strategy and disease prognosis are determined by RVO type (ischemic/non-ischemic. Despite numerous studies and many current CRVO and BRVO treatment approaches, the management of these patients is still being debated. Intravitreal injections of steroids (triamcinolone acetate, dexamethasone and vascular endothelial growth factor (VEGF inhibitors (bevacizumab, ranibizumab were shown to be fairly effective. However, it is unclear whether anti-VEGF agents are reasonable in ischemic RVOs. Laser photocoagulation remains the only effective treatment of optic nerve head and/or retinal neovascularization. Laser photocoagulation is also indicated for the treatment of macular edema. Both threshold and sub-threshold photocoagulation may be performed. Photocoagulation performed with argon (514 nm, krypton (647 nm, or diode (810 nm laser for macular edema provides similar results (no significant differences. The treatment may be complex and include medication therapy and/or surgery. Medication therapy includes anti-aggregant agents and antioxidants, i.e., emoxypine which may be used in acute RVO as well as in post-thrombotic retinopathy. 

  5. Immediate Outcome of Balloon Mitral Valvuloplasty with JOMIVA Balloon during Pregnancy

    Science.gov (United States)

    Ramasamy, Ramona; Kaliappan, Tamilarasu; Gopalan, Rajendiran; Palanimuthu, Ramasmy; Anandhan, Premkrishna

    2017-01-01

    Introduction Rheumatic mitral stenosis is the most common Valvular Heart Disease encountered during pregnancy. Balloon Mitral Valvuloplasty (BMV) is one of the treatment option available if the symptoms are refractory to the medical management and the valve anatomy is suitable for balloon dilatation. BMV with Inoue balloon is the most common technique being followed worldwide. Over the wire BMV is a modified technique using Joseph Mitral Valvuloplasty (JOMIVA) balloon catheter which is being followed in certain centres. Aim To assess the immediate post procedure outcome of over the wire BMV with JOMIVA balloon. Materials and Methods Clinical and echocardiographic parameters of pregnant women with significant mitral stenosis who underwent elective BMV with JOMIVA balloon in our institute from 2005 to 2015 were analysed retrospectively. Severity of breathlessness (New York Heart Association Functional Class), and duration of pregnancy was included in the analysis. Pre procedural echocardiographic parameters which included severity of mitral stenosis and Wilkin’s scoring were analysed. Clinical, haemodynamic and echocardiographic outcomes immediately after the procedure were analysed. Results Among the patients who underwent BMV in our Institute 38 were pregnant women. Twenty four patients (63%) were in New York Heart Association (NYHA) Class III. All of them were in sinus rhythm except two (5%) who had atrial fibrillation. Thirty four patients (89.5%) were in second trimester of pregnancy at the time of presentation and four (10.5%) were in third trimester. Echocardiographic analysis of the mitral valve showed that the mean Wilkin’s score was 7.3. Mean mitral valve area pre procedure was 0.8 cm2. Mean gradient across the valve was 18 mmHg. Ten patients (26.5%) had mild mitral regurgitation and none had more than mild mitral regurgitation. Thirty six patients had pulmonary hypertension as assessed by tricuspid regurgitation jet velocity. All of them underwent BMV

  6. Experience of endovascular treatment of occlusion-stenotic lesions of cerebral arteries

    Directory of Open Access Journals (Sweden)

    Cherednichenko Yu.V.

    2016-03-01

    Full Text Available Objective — to evaluate the efficacy of endovascular techniques in the treatment of occlusion and stenotic lesions of the brachiocephalic and cerebral arteries, to define the ways of complications prevention. Materials and methods. 594 patients with occlusion and stenotic lesions of the brachiocephalic and cerebral arteries were operated by endovascular methods in endovascular center of Dnipropetrovsk Regional Clinical Hospital named after I.I. Mechnikov. 688 endovascular operations were carried out. Most part of the operations are carotid stenting (423 operations. All of these operations were carried out with the usage of different types of antiembolic protection systems: distal, proximal or their combination. Intracranial segments of cerebral arteries were operated in 43 cases. 169 operations of stenting of vertebral arteries in extracranial segments were performed. Subclavian arteries and brachiocephal truncus were operated in 53 cases. Results. Total removal of stenosis was achieved in 588 cases (98.99%. 509 patients (85.69% of cases had improvement in neurological status (on a scale NIHHS, Mrs., MoCA. 77 (12.96% patients had no deterioration of neurological status. Postoperative mortality was 1.01%. Common level of other complications was 4.3 %: cerebral complications - 2.7%. Discussion. The results of the endovascular treatment of occlusion and stenotic lesions of the cerebral arteries show high efficacy and low complication level. The ways of reduction complications level are identified. They are in a differentiated selection of antiembolic protection method, endovascular treatment planning, based on monitoring of changes in the brain hemoperfusion, the emphasis is on the use of the special neurologic deviсes. Conclusions. Endovascular treatment of occlusion and stenotic lesions of the cerebral arteries is effective with a small risk of complications. Risk can be reduced further by the differential choice of antiembolic protection

  7. Relationship of Occlusal Schemes with the Occurrence of Temporomandibular Disorders

    Directory of Open Access Journals (Sweden)

    Dina H. Sugiaman

    2013-07-01

    Full Text Available Masticatory system is a complex functional unit of the body responsible for mastication, speech, and deglutition process. Temporomandibular disorders (TMD is used to describe all functional disturbances of the masticatory system. The etiology of TMD is multifactorial, such as occlusal disharmony and emotional stress. The relationship between occlusion and TMD has been highly debated in dentistry, one of the occlusal factors is the occlusal scheme. Occlusal schemes are defined as bilateral canine guidance, unilateral canine guidance, group function and balanced occlusion. However, studies about the relationship of occlusal schemes and the occurrence of the TMD are still limited and remained controversial. Objective: To investigate the relationship of occlusal schemes witht he occurrence of TMD. Methods: A cross-sectional study was conducted at the Faculty of Dentistry, Uniiversitas Indonesia. A total of 127 students were included in this study. Subjects were examined based on Clinical Helkimo Index and divided into TMD and non-TMD groups. Subjects were categorized as non-TMD groups if the value of the clinical Helkimo index was 0 and as TMD group when the value ranged between 1-25. Results: Balanced occlusion schemes has a greater risk of TMD occurrence with odds ratio value 5.6 and 95% confidence interval 1.188 to 26.331 (p=0.021. Conclusion: Balanced occlusion has a significant relationship with the occurrence of TMD.

  8. 10 meter Sub-Orbital Large Balloon Reflector (LBR) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Besides serving as a launch vehicle, the carrier balloon provides a stable mount for the enclosed telescope. Looking up, the LBR will serve as a telescope. Looking...

  9. Ohmic scaling based on current diffusive ballooning mode

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, Masatoshi; Itoh, Sanae [Kyushu Univ., Kasuga, Fukuoka (Japan). Research Inst. for Applied Mechanics; Fukuyama, Atsushi; Itoh, Kimitaka

    1996-01-01

    Based on the anomalous transport model due to current diffusive ballooning mode turbulence, the global energy confinement time in a tokamak with Ohmic heating is theoretically studied. Relations to empirical scaling laws are also discussed. (author)

  10. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  11. Low Cost Variable Conductance Heat Pipe for Balloon Payload Project

    Data.gov (United States)

    National Aeronautics and Space Administration — While continuously increasing in complexity, the payloads of terrestrial high altitude balloons need a thermal management system to reject their waste heat and to...

  12. Balloon Pump with Floating Valves for Portable Liquid Delivery

    Directory of Open Access Journals (Sweden)

    Yuya Morimoto

    2016-03-01

    Full Text Available In this paper, we propose a balloon pump with floating valves to control the discharge flow rates of sample solutions. Because the floating valves were made from a photoreactive resin, the shapes of the floating valves could be controlled by employing different exposure patterns without any change in the pump configurations. Owing to the simple preparation process of the pump, we succeeded in changing the discharge flow rates in accordance with the number and length of the floating valves. Because our methods could be used to easily prepare balloon pumps with arbitrary discharge properties, we achieved several microfluidic operations by the integration of the balloon pumps with microfluidic devices. Therefore, we believe that the balloon pump with floating valves will be a useful driving component for portable microfluidic systems.

  13. Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study

    OpenAIRE

    2014-01-01

    PURPOSE The occlusal splint has been used for many years as an effective treatment of sleep bruxism. Several methods have been used to evaluate efficiency of the occlusal splints. However, the effect of the occlusal splints on occlusal force has not been clarified sufficiently. The purpose of this study was to evaluate the effect of occlusal splints on maximum occlusal force in patients with sleep bruxism and compare two type of splints that are Bruxogard-soft splint and canine protected hard...

  14. The Hubble party balloon and the expanding universe

    Science.gov (United States)

    Zendri, G.; Rosi, T.; Oss, S.

    2016-09-01

    We show that the metaphor of the inflated balloon used to describe expanding space-time according to the Hubble law can be transformed into a simple laboratory experiment. We obtain, in terms of measured recession speeds and distances of ink dots drawn on a party balloon, easy renditions of various cosmological models, such as the static one and the Einstein-De Sitter universe.

  15. Small Research Balloons in a Physics Course for Education Majors

    Science.gov (United States)

    Bruhweiler, F. C.; Verner, E.; Long, T.; Montanaro, E.

    2013-12-01

    At The Catholic Univ. of America, we teach an experimental physics course entitled Physics 240: The Sun-Earth Connection, which is designed for the undergraduate education major. The emphasis is on providing hands-on experience and giving the students an exciting experience in physics. As part of this course, in the Spring 2013 semester, we instituted a project to plan, build, launch, and retrieve a small (~1.3 kg) research balloon payload. The payload flown was a small GPS unit that sent its position to an Internet site, a small wide-angle high-resolution video camera, and an analog refrigerator thermometer placed in the field of view of the camera. All data were stored on the camera sim-card. Students faced the problems of flying a small research balloon in the congested, densely populated Northeast Corridor of the US. They used computer simulators available on the Web to predict the balloon path and flight duration given velocities for the Jet Stream and ground winds, as well as payload mass and amount of helium in the balloon. The first flight was extremely successful. The balloon was launched 140 km NW of Washington DC near Hagerstown, MD and touched down 10 miles (16 km) NW of York, PA, within 1.6 km of what was predicted. The balloon reached 73,000 ft (22,000 m) and the thermometer indicated temperatures as low as -70 degrees Fahrenheit (-57 C) during the flight. Further balloon flights are planned in conjunction with this course. Additional exercises and experiments will be developed centered around these flights. Besides learning that science can be exciting, students also learn that science is not always easily predictable, and that these balloon flights give an understanding of many of problems that go into real scientific space missions. This project is supported in part by an educational supplement to NASA grant NNX10AC56G

  16. Analysis of current diffusive ballooning mode in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Morihisa [Faculty of Engineering, Okayama University, Okayama (Japan); Fukuyama, Atsushi [Kyoto Univ. (Japan). Dept. of Nuclear Engineering; Itoh, Kimitaka [National Inst. for Fusion Science, Toki, Gifu (Japan); Itoh, Sanae-I.; Yagi, Masatoshi [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    2000-07-01

    The effect of finite gyroradius on the current diffusive ballooning mode is examined. Starting from the reduced MHD equations including turbulent transports, coupling with drift motion and finite gyroradius effect of ions, we derive a ballooning mode equation with complex transport coefficients. The eigenfrequency, saturation level and thermal diffusivity are evaluated numerically from the marginal stability condition. Preliminary results of their parameter dependence are presented. (author)

  17. Intrauterine tamponade balloon use in the treatment of uterine inversion

    OpenAIRE

    Haeri, Sina; Rais, Sheliza; Monks, Brian

    2015-01-01

    Uterine inversion is a rare but life-threatening obstetrical emergency that occurs when the fundus of the uterus prolapses through the cervix, hence turning the uterus inside out. In this case report, we present our experience using an intrauterine tamponade balloon for management of uterine inversion, and a review of the literature. The utility of an intrauterine tamponade balloon in cases of uterine inversion, especially when maternal medical conditions preclude the use of uterotonics, or r...

  18. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall

    1997-01-01

    arteries remained patent. Two occlusions and two stenoses developed during the first 3 months after the intervention and one occlusion occurred after 1 year. The following IVUS parameters were related to a favourable patency: presence of calcification; dissection or plaque rupture and residual stenosis...

  19. Femoral bifurcation disease: balloon or knife.

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen

    2009-10-01

    Arterial occlusive disease at the level of the femoral bifurcation mostly occurs in combination with inflow and/or outflow lesions. Surgical endarterectomy of the femoral bifurcation is a well-proven low-risk and easy surgical intervention with known durable success, while, although proven to be safe, evidence is lacking about the durability of the endovascular approach. Based on the evidence at hand, the surgical approach should be recommended for the vast majority of patients and the endovascular approach should only be indicated as the first strategy in selected cases presenting with factors that might compromise the outcome of surgery in the groin. If feasible, the hybrid approach with endarterectomy at the level of the bifurcation and endovascular repair of the inflow and outflow lesions is preferred in patients with multilevel disease.

  20. Introduction (Special Issue on Scientific Balloon Capabilities and Instrumentation)

    Science.gov (United States)

    Gaskin, Jessica A.; Smith, I. S.; Jones, W. V.

    2014-01-01

    In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3,000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science.) Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.

  1. Development of a tiny tandem balloon system for atmospheric observation

    Science.gov (United States)

    Saito, Yoshitaka; Yamada, Kazuhiko; Fujiwara, Masatomo

    2016-07-01

    A tandem balloon system with a combination of a zero-pressure balloon on top and a super-pressure balloon on the bottom has a unique trajectory characteristic, with different flight altitudes between day and night and thus with ascending and descending motions at dawn and dusk, respectively. This characteristic provides a unique opportunity to explore the atmosphere, e.g., the upper tropospheric and lower stratospheric region with cross-tropopause measurements twice a day. We started development of a tiny tandem balloon system using a 10 m^{3} super-pressure balloon and a 100 m^{3} zero-pressure balloon, with a capability of carrying 3 kg of payload. One of the scientific targets is to measure water vapor, cloud particles, and temperature around the tropical tropopause which is the entry point of the stratospheric and mesospheric meridional circulation. For the data transfer, the iridium satellite communication module, SBD9603 is used. In this paper, the current status of the development will be reported.

  2. Catching Comet's Particles in the Earth's Atmosphere by Using Balloons

    Science.gov (United States)

    Potashko, Oleksandr; Viso, Michel

    The project is intended to catch cometary particles in the atmosphere by using balloons. The investigation is based upon knowledge that the Earth crosses the comet’s tails during the year. One can catch these particles at different altitudes in the atmosphere. So, we will be able to gradually advance in the ability to launch balloons from low to high altitudes and try to catch particles from different comet tails. The maximum altitude that we have to reach is 40 km. Both methods - distance observation and cometary samples from mission Stardust testify to the presence of organic components in comet’s particles. It would be useful to know more details about this organic matter for astrobiology; besides, the factor poses danger to the Earth. Moreover, it is important to prove that it is possible to get fundamental scientific results at low cost. In the last 5 years launching balloons has become popular and this movement looks like hackers’ one - as most of them occur without launch permission to airspace. The popularity of ballooning is connected with low cost of balloon, GPS unit, video recording unit. If you use iPhone, you have a light solution with GPS, video, picture and control function in one unit. The price of balloon itself begins from $50; it depends on maximum altitude, payload weight and material. Many university teams realized balloon launching and reached even stratosphere at an altitude of 33 km. But most of them take only video and picture. Meanwhile, it is possible to carry out scientific experiments by ballooning, for example to collect comet particles. There is rich experience at the moment of the use of mineral, chemical and isotopic analysis techniques and data of the comet’s dust after successful landing of StarDust capsule with samples in 2006. Besides, we may use absolutely perfect material to catch particles in the atmosphere, which was used by cosmic missions such as Stardust and Japanese Hayabusa. As to balloon launches, we could use

  3. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group.

    OpenAIRE

    Serruys, P.W.; de Jaegere, P; Kiemeneij, F.; Macaya, C; Rutsch, W; Heyndrickx, G.; Emanuelsson, H.; Marco, J.; Legrand, Victor; Materne, P.

    1994-01-01

    BACKGROUND: Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as compared with standard balloon angioplasty. METHODS: A total of 520 patients with stable angina and a single coronary-artery lesion were randomly assigned to either stent implantation (262 patients)...

  4. Importance of occlusion aspects in the completion of orthodontic treatment

    OpenAIRE

    2007-01-01

    The purpose of this study was to address the therapeutic goals regarding the static and functional occlusion in the completion of orthodontic treatment. For such purpose, a study population comprising 20 female treated Class II malocclusion subjects with an initial mean age of 11 years underwent a two-phase treatment (orthopedics and orthodontics). The patients were diagnosed in centric relation and were treated according to the six keys for normal occlusion and functional occlusal parameters...

  5. Occlusal adjustment in the treatment of secondary traumatic injury

    Directory of Open Access Journals (Sweden)

    Raulino Naves Borges

    2011-01-01

    Full Text Available The success of the rehabilitation treatment is associated with the relationship between occlusion and periodontal status. When occlusal loads exceed the ability of the periodontium to resist and distribute the resulting forces, injuries may develop, leading to failures in dental practice. A 35-year-old female patient presented at the Occlusion and Orofacial Pain Research Center at the School of Dentistry, Universidade Federal de Goiás, Brazil, complaining of pain and mobility in the maxillary central incisors and sensitivity in the mandibular left incisors and canine. Symptoms began after cast metal restoration was performed in tooth #27. Clinical examination revealed a signifi cant difference of 1 mm between centric relation and habitual occlusion, presence of a periodontal pocket 5 mm deep in the mesial aspect of tooth #11, and an increased vertical dimension of occlusion caused by occlusal interference between teeth #27 and #37. Radiographic examination detected vertical bone loss between teeth #21 and #11, on the mesial aspect of tooth #33 and between the lower incisors. The lower teeth also showed radiographic evidence of periapical lesions. Occlusal interference caused anterior projection of the mandible to the right, overloading the incisors. Treatment by occlusal adjustment was performed to promote an equal incidence of forces on all aspects of the teeth. Twelve sessions were required to achieve a balanced occlusion and restore the physiological vertical dimension of occlusion. Six months after treatment, there was radiographic evidence of newly formed bone tissue between teeth #11 and #21, regression of apical periodontitis in the lower teeth, and a decrease in mobility and all associated symptoms. Secondary traumatic injury may be responsible for changes in apical tooth structures. Occlusal adjustment may favor the direction of occlusal forces to the long axis of the teeth.

  6. The correction of occlusal vertical dimension on tooth wear

    Directory of Open Access Journals (Sweden)

    Rostiny Rostiny

    2007-12-01

    Full Text Available The loss of occlusal vertical dimension which is caused by tooth wear is necessarily treated to regain vertical dimension. Correctional therapy should be done as early possible. In this case, simple and relatively low cost therapy was performed. In unserve loss of occlusal vertical dimension, partial removable denture could be used and the improvement of lengthening anterior teeth using composite resin to improve to regain vertical dimensional occlusion.

  7. Cephalometric Indicators of the Vertical Dimension of Occlusion

    OpenAIRE

    Strajnić, Ljiljana; Stanišić-Sinobad, Darinka; Marković, Dubravka; Stojanović, Ljiljana

    2008-01-01

    The aim of this investigation was to establish precise indicators of the vertical dimension of occlusion (VDO) which could be used as objective parameters in prosthodontic treatment providing exact control of the reconstructed vertical dimension of occlusion, early detection of errors and correction of the vertical dimension of occlusion during complete denture manufacturing. A total of 60 lateral cephalometric radiographs of subjects with natural dentition and class I skeletal ja...

  8. Arterial gas occlusions in operating heat pipes

    Science.gov (United States)

    Saaski, E. W.

    1975-01-01

    The effect of noncondensable gases on high performance arterial heat pipes has been investigated both analytically and experimentally. Models have been generated which characterize the dissolution of gases in condensate and the diffusional loss of dissolved gases from condensate in arterial flow. These processes, and others, have been used to postulate stability criteria for arterial heat pipes. Experimental observations of gas occlusions were made using a stainless steel heat pipe equipped with viewing ports, and the working fluids methanol and ammonia with the gas additives helium, argon, and xenon. Observations were related to gas transport models.

  9. Electro-oculogram of Retinal Vein Occlusion

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    Twenty five cases, including 26 eyes with retinal vein occlusion (RVO) were examined by means of the electro-oculogram. The results showed that 23 of the 26 eyes suffering from RVO exhibited abnormalities of the electro-oculogram (EOG). The potential difference and Arden ratio in the RVO eyes were lower than those in the normal eyes (P<0.01). The more the visual acuity of ill eyes was decreased, the higher the abnormal rate of EOG in ill eyes was. 14 eyes had the visual acuity less than 0.1, whose EOGs ...

  10. Burn Injury Arise From Flying Balloon Toys

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2007-08-01

    Full Text Available Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloons flame. 80 person was injured from flying toy ballons flame in a meeting in 2002. Although this potential risks of acetylene, helium have not any of some risk. But helium was provided from other countries and have more price. The injuries which caused from acetylene burns like 1st -2nd degree burns. Consequently that was known helium is more avaliable for using in toy sector, and never cause burn injuries like this. [TAF Prev Med Bull 2007; 6(4.000: 291-296

  11. Balloon borne arcsecond pointer feasibility study

    Science.gov (United States)

    Ward, Philip R.; Deweese, Keith D.

    2003-08-01

    A major hurdle in extending the range of experiments for which balloon vehicles are useful has been the imposition of the gondola dynamics on the accuracy with which an instrument can be kept pointed at a celestial target. In this paper, the foundation for a high fidelity controller simulation is presented and it is shown that sub-arcsecond pointing stability can be achieved for a large instrument pointing at an inertial target. The flexibility of the flight train is represented through generalized modal analysis. A multiple controller scheme is introduced with a coarse azimuth pointer and a pitch-yaw gimbal mount for fine pointing. An analysis and demonstration of the necessity in eliminating static friction are provided along with a solution to eliminate static friction from the system dynamics. A control scheme involving linear accelerometers for enhanced disturbance rejection is also presented. This paper establishes that the proposed control strategy can be made robustly stable with significant design margins. Also demonstrated is the efficacy of the proposed system in rejecting disturbances larger than those considered realistic.

  12. Ballooning mode spectrum in general toroidal systems

    Energy Technology Data Exchange (ETDEWEB)

    Dewar, R.L.; Glasser, A.H.

    1982-04-01

    A WKB formalism for constructing normal modes of short-wavelength ideal hydromagnetic, pressure-driven instabilities (ballooning modes) in general toroidal magnetic containment devices with sheared magnetic fields is developed. No incompressibility approximation is made. A dispersion relation is obtained from the eigenvalues of a fourth order system of ordinary differential equations to be solved by integrating along a line of force. Higher order calculations are performed to find the amplitude equation and the phase change at a caustic. These conform to typical WKB results. In axisymmetric systems, the ray equations are integrable, and semiclassical quantization leads to a growth rate spectrum consisting of an infinity of discrete eigenvalues, bounded above by an accumulation point. However, each eigenvalue is infinitely degenerate. In the nonaxisymmetric case, the rays are unbounded in a four dimensional phase space, and semiclassical quantization breaks down, leading to broadening of the discrete eigenvalues and accumulation point of the axisymmetric case into continuum bands. Analysis of a model problem indicates that the broadening of the discrete eigenvalues is numerically very small, the dominant effect being broadening of the accumulation point.

  13. Percutaneous balloon valvuloplasty in mitral stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Oh, Byung Hee; Park, Kyung Ju; Kim, Seung Hyup; Lee, Young Woo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1989-02-15

    Percutaneous balloon valvuloplasty(PBV) was successfully performed in 8 mitral stenosis patients for recent 3 months. Five patients have aortic insufficiencies also and two patients have mitral regurgitations below grade II/IV. All patients showed sinus rhythm on EKG, and had no mitral valvular calcification on echocardiography and fluoroscopy. PBV resulted in an increase in mitral valve area from 1.22{+-}0.22 to 2.57{+-}0.86 cm{sup 2}, a decrease in mean left atrial pressure from 23.4{+-}9.6 to 7.5{+-}3.4 mmHg and a decrease in mean mitral pressure gradient from 21.3{+-}9.4 to 6.8{+-}3.1 mmHg. There were no significant complications except 2 cases of newly appeared and mildly aggravated mitral regurgitation. We believe that PBV will become a treatment modality of choice replacing surgical commissurotomy or valve replacement in a group of mitral stenosis patients, because of its effectiveness and safety.

  14. Burn Injury Arise From Flying Balloon Toys

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2007-08-01

    Full Text Available Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloons flame. 80 person was injured from flying toy ballons flame in a meeting in 2002. Although this potential risks of acetylene, helium have not any of some risk. But helium was provided from other countries and have more price. The injuries which caused from acetylene burns like 1st -2nd degree burns. Consequently that was known helium is more avaliable for using in toy sector, and never cause burn injuries like this. [TAF Prev Med Bull. 2007; 6(4: 291-296

  15. Optical coherence tomography monitoring of angioplasty balloon inflation in a deployment tester

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Bourezak, Rafik; Boulet, Benoit; Lamouche, Guy

    2010-08-01

    We present an innovative integration of an intravascular optical coherence tomography probe into a computerized balloon deployment system to monitor the balloon inflation process. The high-resolution intraluminal imaging of the balloon provides a detailed assessment of the balloon quality and, consequently, a technique to improve the balloon manufacturing process. A custom-built swept-source optical coherence tomography system is used for real-time imaging. A semicompliant balloon with a nominal diameter of 4 mm is fabricated for the experiments. Imaging results correspond to balloon deployment in air and inside an artery phantom. A characterization of the balloon diameter, wall thickness, compliance, and elastic modulus is provided, based on image segmentation. Using the images obtained from the probe pullback, a three-dimensional visualization of the inflated balloon is presented.

  16. Hydrocolloid occlusion for the treatment of neurovascular corns

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Beck, Jan Walther; Reumert, L N

    1991-01-01

    The goal of this study was to determine the effect of hydrocolloid occlusion on neurovascular corns. The design was an observer-blinded, randomized, controlled study. Thirty consecutive patients participated in the trial. The patients received curettage alone or curettage with hydrocolloid...... occlusion. Six treatments were given over 12 weeks. A follow-up examination was performed 3 months after termination of the trial. Outcome measures were the size of the corns, a discomfort score, and an overall judgment of the trial. The results demonstrated no benefit of occlusion for symptoms or signs...... of neurovascular corns. The patients treated with occlusion were, however, generally more satisfied than the conventional group....

  17. Radiation Retinopathy Associated with Central Retinal Vein Occlusion

    Institute of Scientific and Technical Information of China (English)

    Yan; Liu; FengWen

    2007-01-01

    Purpose: To report a case of radiation retinopathy associated with central retinal vein occlusion.Methods: The clinical features and fundus fluorescein angiography of this case were analyzed.Results: The patient had been treated with radiotherapy for her nasopharyngeal carcinoma, and presented with sudden visual loss in the left eye. The funduscopic examination and fluorescein angiography showed the features of radiation retinopathy in both eyes, and central retinal vein occlusion in the left eye.Conclusions: Radiation retinopathy can be associated with central retinal vein occlusion in the same eye, and it seems that the endothelial cell loss caused by radiation retinopathy may lead to retinal vein occlusion.

  18. The occlusal guard: a simplified technique for fabrication and equilibration.

    Science.gov (United States)

    Antonelli, John; Hottel, Timothy L; Siegel, Sharon C; Brandt, Robert; Silva, Gladston

    2013-01-01

    Hard occlusal guards have been used effectively to treat myofacial pain originating from parafunctional activities. Also, they can protect the natural dentition when it opposes porcelain restorations, help to evaluate changes in occlusal vertical dimension during full mouth rehabilitation, minimize further tooth loss in patients with abfraction lesions, and redirect occlusal loads more favorably onto dental implant-supported prostheses. A simplified technique is described to fabricate a properly designed wax model of an occlusal guard that can be processed in acrylic in the same manner used to construct a complete denture.

  19. Intragastric balloon followed by diet vs intragastric balloon followed by another balloon: a prospective study on 100 patients.

    Science.gov (United States)

    Genco, Alfredo; Cipriano, Massimiliano; Bacci, Vincenzo; Maselli, Roberta; Paone, Emanuela; Lorenzo, Michele; Basso, Nicola

    2010-11-01

    Aim of this study is to compare the efficacy of BioEnterics Intragastric Balloon (BIB®) followed by diet with BIB followed by another BIB. A prospective study was designed: a homogeneous group of 100 obese patients (age range 25-35, BMI range 40.0-44.9, M/F ratio 1/4) was allocated into two groups according to procedure: BIB (6 months) followed by diet therapy (7 months; group A = 50 pts), BIB positioning followed by another BIB after 1 month (group B = 50 pts). Baseline demographics were similar in both groups (Group A 10M/40F; mean age 31.4 ± 2.6; range 25-35; mean weight 106.3 ± 12.5 Kg; range 88-150; mean BMI 42.6±2.7 Kg/m(2); range 40.2-43.8; Group B 10M/40F; mean age 32.1 ± 2.1; range 25-35; mean weight 107.1 ± 11.9 Kg; range 90-150; mean BMI 42.9 ± 2.3; range 40.2-43.9). In both groups, weight loss parameters (Kg, BMI, and % EBL) were considered. Statistics were by Fisher's exact test (p < 0.05 was considered significant). At the time of 1st BIB removal, weight loss parameters in both groups were not significantly different: Group A: mean weight was 83.7±19.1 (range 52-151); mean BMI 34.2 ± 3.9 (range 32.4-43.8); and mean %EBL 43.5 ± 21.1 (range 0-68). Group B: mean weight was 84.9 ± 18.3 (range 50-148); mean BMI 34.8 ± 3.3 (range 32.4-43.8); and mean % EBL 45.2 ± 22.5% (range 0-68). At the study end, weight loss parameters were significantly lower in patients who underwent consecutive BIB (p < 0.05): mean BMI was 30.9 ± 7.2 Kg/m(2) (range 24-40), and 35.9 ± 9.7 Kg/m(2) (range 34-42); mean % EBL was 51.9 ± 24.6% (range 0-100) and 25.1 ± 26.2% (range 0-100) in group B and A, respectively. As compared with diet, a second intragastric balloon can be positioned without difficulties, achieving good results with continuous weight loss.

  20. Diagnostic Pitfalls in Postinterventional Intraarterial Magnetic Resonance Angiography after Recanalization of Femoropopliteal Arterial Occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Huegli, R.W.; Aschwanden, M.; Kos, S.; Rasmus, M.; Jaeger, K.; Jacob, A.L.; Bilecen, D. (Dept. of Radiology and Dept. of Angiology, Univ. Hospital of Basel, Basel (Switzerland))

    2008-12-15

    Background: Magnetic resonance (MR)-guided vascular interventions are of increasing interest, and, with the use of contrast-enhanced techniques, intraarterial contrast-enhanced MR angiography (ia-ce-MRA) competes with intraarterial digital subtraction angiography (ia-DSA) for the diagnostic evaluation of the infrainguinal vessel tree. Purpose: To assess the diagnostic value of ia-ce-MRA and high-resolution T1-weighted (hr-T1w) imaging compared to the gold-standard ia-DSA for residual stenosis and local dissections after femoropopliteal recanalization in patients with peripheral arterial occlusive disease (PAOD). Material and Methods: Eight patients with PAOD and short vessel occlusion of their femoropopliteal arteries underwent recanalization and balloon positioning under DSA. Patients were transferred to a short-bore MR scanner. Percutaneous transluminal angioplasty (PTA) was accomplished under MR fluoroscopy. Pre- and postinterventional ia-ce three-dimensional (3D) gradient-echo MRA with gadopentate dimeglumine was performed using the intraarterial introducer sheath. Maximum intensity projections (MIP) and multiplanar reconstructions (MPR) were calculated from the data set. High-resolution T1w images of the angioplasty region before and after dilatation were acquired. Control ia-DSA images were obtained. Results: The postinterventional angioplasty results for stenosis grading were comparable in ia-MRA and ia-DSA. Only two of five local dissections in ia-DSA were visualized with the ia-ce-MRA runs including MIPs and MPRs. To clearly depict dissection, hr-T1w images were needed. Conclusion: Grading of stenotic lesions with ia-ce-MRA after PTA is comparable to ia-DSA. Intraarterial ce-MRA with calculated MIPs and MPRs is only partially sufficient to visualize local dissections after PTA. High-resolution T1w images are required for precise diagnosis of dissections in magnetic resonance tomography

  1. Diagnostic Pitfalls in Postinterventional Intraarterial Magnetic Resonance Angiography after Recanalization of Femoropopliteal Arterial Occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Huegli, R.W.; Aschwanden, M.; Kos, S.; Rasmus, M.; Jaeger, K.; Jacob, A.L.; Bilecen, D. [Dept. of Radiology and Dept. of Angiology, Univ. Hospital of Basel, Basel (Switzerland)

    2008-12-15

    Background: Magnetic resonance (MR)-guided vascular interventions are of increasing interest, and, with the use of contrast-enhanced techniques, intraarterial contrast-enhanced MR angiography (ia-ce-MRA) competes with intraarterial digital subtraction angiography (ia-DSA) for the diagnostic evaluation of the infrainguinal vessel tree. Purpose: To assess the diagnostic value of ia-ce-MRA and high-resolution T1-weighted (hr-T1w) imaging compared to the gold-standard ia-DSA for residual stenosis and local dissections after femoropopliteal recanalization in patients with peripheral arterial occlusive disease (PAOD). Material and Methods: Eight patients with PAOD and short vessel occlusion of their femoropopliteal arteries underwent recanalization and balloon positioning under DSA. Patients were transferred to a short-bore MR scanner. Percutaneous transluminal angioplasty (PTA) was accomplished under MR fluoroscopy. Pre- and postinterventional ia-ce three-dimensional (3D) gradient-echo MRA with gadopentate dimeglumine was performed using the intraarterial introducer sheath. Maximum intensity projections (MIP) and multiplanar reconstructions (MPR) were calculated from the data set. High-resolution T1w images of the angioplasty region before and after dilatation were acquired. Control ia-DSA images were obtained. Results: The postinterventional angioplasty results for stenosis grading were comparable in ia-MRA and ia-DSA. Only two of five local dissections in ia-DSA were visualized with the ia-ce-MRA runs including MIPs and MPRs. To clearly depict dissection, hr-T1w images were needed. Conclusion: Grading of stenotic lesions with ia-ce-MRA after PTA is comparable to ia-DSA. Intraarterial ce-MRA with calculated MIPs and MPRs is only partially sufficient to visualize local dissections after PTA. High-resolution T1w images are required for precise diagnosis of dissections in magnetic resonance tomography.

  2. Extradural balloon obliteration of the empty sella report of three cases (intrasellar balloon obliteration).

    Science.gov (United States)

    Gazioğlu, N; Akar, Z; Ak, H; Işlak, C; Koçer, N; Seçkin, M S; Kuday, C

    1999-01-01

    Empty sella syndrome is an anatomical and clinical entity composed of intrasellar reposition of the CSF and compression of the pituitary tissue, resulting in a clinical picture of headache, visual field defect, CSF rhinorrhea and some mild endocrinological disturbances. While some cases are primary with no appreciable aetiology, secondary cases are associated with prior operation or radiotherapy of the region. In our series, 3 patients with primary empty sella syndrome were treated by the current approach of extradural filling of the sellar cavity. This technique was first described by Guiot and widely accepted thereafter. We used a detachable silicon balloon filled with HEMA or liquid silicone for obliteration of the sellar cavity and obtained clinically satisfactory results without complications. Visual symptoms regressed and headache disappeared. But at long term follow-up all the balloons were found to be deflated. Despite the facility and efficacy of the technique we do not recommend it in the treatment of the empty sella because the filling of the sella is only transient and relapses may occur.

  3. Balloon dacryocystoplasty: Incomplete versus complete obstruction of the nasolacrimal system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Lee, Sang Hoon; Han, Young Min; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul [Chung Ang University College of Medicine, Seoul (Korea, Republic of); Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1993-07-15

    Balloon dilatation of nasolacrimal drainage apparatus was attempted for the treatment of stenoses or obstructures of the nasolacrimal system in 49 eyes of 41 consecutive patients with complete obstructions and 16 eyes of 14 patients with incomplete obstructions. These two groups were compared with regards to the effectiveness of balloon dacryocystoplasty. All patients suffered from severe epiphora had already undergone multiple probings. A 0.018 inch hair or ball guide wire was introduced through the superior punctum into the inferior meatus of the nasal cavity and pulled out through the nasal aperture using a hemostat under nasal endoscopy. A deflated angiography balloon catheter was then introduced in a retrograde direction and dilated under fluoroscopic control. No major complications occurred in any of the patients. At 7 days after balloon dilatation, 25 of 49 eyes with complete obstruction demonstrated improvement in epiphora (initial success rate: 51.0%) and among them 17 eyes showed complete resolution of symptoms. Reocclusion occurred in 12 of the 25 eyes with initial improvement at the 2 months follow up. For the 16 eyes with incomplete obstruction, and improvement of epiphora was attained in 11 eyes (initial success rate 68.8%): 5 of these eyes showed complete resolution of epiphora, and 3 was failed to maintain initial improvement at the 2 month follow up. Although this study demonstrate that results of balloon dacryocystoplasty are not encouraging because of the high failure and recurrence rate, balloon dacryocystoplasty is a simple and safe nonsurgical technique that can be used to treat for obstructions of the nasolacrimal system. In addition, balloon dacryocystoplasty shows better results in incomplete obstruction than in complete obstruction than complete obstruction of the nasolacrimal system.

  4. Coolability of ballooned VVER bundles with pellet relocation

    Energy Technology Data Exchange (ETDEWEB)

    Hozer, Z.; Nagy, I.; Windberg, P.; Vimi, A. [AEKI, P.O.box 49, Budapest, H-1525 (Hungary)

    2009-06-15

    During a LOCA incident the high pressure in the fuel rods can lead to clad ballooning and the debris of fuel pellets can fill the enlarged volume. The evaluation of the role of these two effects on the coolability of VVER type fuel bundles was the main objective of the experimental series. The tests were carried out in the modified configuration of the CODEX facility. 19-rod electrically heated VVER type bundle was used. The test section was heated up to 600 deg. C in steam atmosphere and the bundle was quenched from the bottom by cold water. Three series of tests were performed: 1. Reference bundle with fuel rods without ballooning, with uniform power profile. 2. Bundle with 86% blockage rate and with uniform power profile. The blockage rate was reached by superimposing hollow sleeves on all 19 fuel rods. 3. Bundle with 86% blockage rate and with local power peak in the ballooned area. The local power peak was produced by the local reduction the cross section of the internal heater bar inside of the fuel rods. In all three bundle configurations three different cooling water flow-rates were applied. The experimental results confirmed that a VVER bundle with even 86% blockage rate remains coolable after a LOCA event. The ballooned section creates some obstacles for the cooling water during reflood of the bundle, but this effect causes only a short delay in the cooling down of the hot fuel rods. Earlier tests on the coolability of ballooned bundles were performed only with Western type bundles with square fuel lattice. The present test series was the first confirmation of the coolability of VVER type bundles with triangular lattice. The accumulation of fuel pellet debris in the ballooned volume results in a local power peak, which leads to further slowing down of quench front. The first tests indicated that the effect of local power peak was less significant on the delay of cooling down than the effect of ballooning. (authors)

  5. The University of Alberta High Altitude Balloon Program

    Science.gov (United States)

    Johnson, W.; Buttenschoen, A.; Farr, Q.; Hodgson, C.; Mann, I. R.; Mazzino, L.; Rae, J.; University of Alberta High Altitude Balloon Team

    2011-12-01

    The University of Alberta High Altitude Balloon (UA-HAB) program is a one and half year program sponsored by the Canadian Space Agency (CSA) that offers hands on experience for undergraduate and graduate students in the design, build, test and flight of an experimental payload on a high altitude balloon platform. Utilising low cost weather balloon platforms, and through utilisation of the CSA David Florida Laboratory for thermal-vacuum tests , in advance of the final flight of the payload on a NASA high altitude balloon platform. Collectively the program provided unique opportunities for students to experience mission phases which parallel those of a space satellite mission. The program has facilitated several weather balloon missions, which additionally provide educational opportunities for university students and staff, as well as outreach opportunities among junior and senior high school students. Weather balloon missions provide a cheap and quick alternative to suborbital missions; they can be used to test components for more expensive missions, as well as to host student based projects from different disciplines such as Earth and Atmospheric Sciences (EAS), Physics, and Engineering. In addition to extensive skills development, the program aims to promote recruitment of graduate and undergraduate students into careers in space science and engineering. Results from the UA-HAB program and the flight of the UA-HAB shielded Gieger counter payload for cosmic ray and space radiation studies will be presented. Lessons learned from developing and maintaining a weather balloon program will also be discussed. This project is undertaken in partnership with the High Altitude Student Platform, organized by Louisiana State University and the Louisiana Space Consortium (LaSpace), and sponsored by NASA, with the financial support of the Canadian Space Agency.

  6. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    Science.gov (United States)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  7. Metabolic syndrome and central retinal artery occlusion

    Directory of Open Access Journals (Sweden)

    Kosanović-Jaković Natalija

    2005-01-01

    Full Text Available Background. The accumulation of risk factors for central retinal artery occlusion can be seen in a single person and might be explained by the metabolic syndrome. Case report. We presented the case of a 52-year-old man with no light perception in his right eye. The visual loss was monocular and painless, fundoscopy showed central retinal artery occlusion and the laboratory investigation showed the raised erythrocyte sedimentation rate of 105 mm/h and the raised C-reactive protein of 22 mg/l. Specific laboratory investigations and fluorescein angiography excluded the presence of vasculitis, collagen vascular diseases, hypercoagulable state and antiphospholipid syndrome. Conclusion. The patient met all the five of the National Cholesterol Education Program (NCEP criteria for the metabolic syndrome: hypertension, abnormal lipid profile, abnormal glucose metabolism, obesity and hyperuricemia. Measurement of C-reactive protein is useful for the assessment of therapeutic systemic effect on any abnormality in the metabolic syndrome. Individual therapy for all risk factors in the metabolic syndrome is necessary to prevent complications such as cardiovascular, retinal vascular diseases and stroke.

  8. Numerical analysis of human dental occlusal contact

    Science.gov (United States)

    Bastos, F. S.; Las Casas, E. B.; Godoy, G. C. D.; Meireles, A. B.

    2010-06-01

    The purpose of this study was to obtain real contact areas, forces, and pressures acting on human dental enamel as a function of the nominal pressure during dental occlusal contact. The described development consisted of three steps: characterization of the surface roughness by 3D contact profilometry test, finite element analysis of micro responses for each pair of main asperities in contact, and homogenization of macro responses using an assumed probability density function. The inelastic deformation of enamel was considered, adjusting the stress-strain relationship of sound enamel to that obtained from instrumented indentation tests conducted with spherical tip. A mechanical part of the static friction coefficient was estimated as the ratio between tangential and normal components of the overall resistive force, resulting in μd = 0.057. Less than 1% of contact pairs reached the yield stress of enamel, indicating that the occlusal contact is essentially elastic. The micro-models indicated an average hardness of 6.25GPa, and the homogenized result for macroscopic interface was around 9GPa. Further refinements of the methodology and verification using experimental data can provide a better understanding of processes related to contact, friction and wear of human tooth enamel.

  9. Dental occlusion: modern concepts and their application in implant prosthodontics.

    Science.gov (United States)

    Carlsson, Gunnar E

    2009-01-01

    The aim of this article was to review the literature on various aspects of occlusion related to implant prosthodontics, using PubMed and the Cochrane library. Even if the number of studies on implants and prosthodontics is very large, no randomized controlled trials or Cochrane reviews were found on the possible influence of occlusal design or characteristics of occlusion on treatment outcome. Therefore, studies and articles of a lower evidence level were accepted as the main part of the review. The widely spread opinion that implants are superior to natural teeth was refuted by two recent consensus conferences, which concluded that the long-term outcome of implant restorations is not better than that of natural teeth. No controlled studies on the optimal features of a harmonious natural and/or restored occlusion, including implant prostheses, were found. Nor was there any evidence that more sophisticated methods in jaw registration, e.g., using face-bows and adjustable articulators, compared with simpler methods, will yield better clinical prosthodontic results. This article discusses, among other things, concepts of occlusion of implant-supported restorations, occlusal material, cantilevers, and occlusal risk factors. Within the limitations of the review, it was concluded that many factors can influence implant failure and peri-implant bone loss but that little is known of the relative importance of such factors. Most probably, however, occlusal factors and details of occlusion are in general of minor importance for the outcome of implant restorations. Occlusion can be managed successfully by using simple methods for jaw registration and different occlusal concepts.

  10. Complexity Analysis of Balloon Drawing for Rooted Trees

    CERN Document Server

    Lin, Chun-Cheng; Poon, Sheung-Hung; Fan, Jia-Hao

    2010-01-01

    In a balloon drawing of a tree, all the children under the same parent are placed on the circumference of the circle centered at their parent, and the radius of the circle centered at each node along any path from the root reflects the number of descendants associated with the node. Among various styles of tree drawings reported in the literature, the balloon drawing enjoys a desirable feature of displaying tree structures in a rather balanced fashion. For each internal node in a balloon drawing, the ray from the node to each of its children divides the wedge accommodating the subtree rooted at the child into two sub-wedges. Depending on whether the two sub-wedge angles are required to be identical or not, a balloon drawing can further be divided into two types: even sub-wedge and uneven sub-wedge types. In the most general case, for any internal node in the tree there are two dimensions of freedom that affect the quality of a balloon drawing: (1) altering the order in which the children of the node appear in...

  11. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    This paper presents a study of pumpkin-shaped superpressure balloons consisting of gores made from a thin polymeric film attached to high stiffness meridional tendons This type of design is being used for the NASA ULDB balloons The gore film shows considerable time-dependent stress relaxation whereas the behaviour of the tendons is essentially time-independent Upon inflation and pressurization the instantaneous i e linear-elastic strain and stress distributions in the film show significantly higher values in the meridional direction However over time and due to the biaxial visco-elastic stress relaxation of the the gore material the em hoop strains increase and the em meridional stresses decrease whereas the em remaining strain and stress components remain substantially unchanged These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission both in terms of the material performance and the overall stability of the shape of the balloon An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter 48 gore pumpkin balloon is presented The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature The results show good correlation with a numerical study using the ABAQUS finite-element package that includes a widely used model of

  12. Ballooning osteolysis in 71 failed total ankle arthroplasties.

    Science.gov (United States)

    Singh, Gurpal; Reichard, Theresa; Hameister, Rita; Awiszus, Friedemann; Schenk, Katja; Feuerstein, Bernd; Roessner, Albert; Lohmann, Christoph

    2016-08-01

    Background and purpose - Aseptic loosening is a major cause of failure in total ankle arthroplasty (TAA). In contrast to other total joint replacements, large periarticular cysts (ballooning osteolysis) have frequently been observed in this context. We investigated periprosthetic tissue responses in failed TAA, and performed an element analysis of retrieved tissues in failed TAA. Patients and methods - The study cohort consisted of 71 patients undergoing revision surgery for failed TAA, all with hydroxyapatite-coated implants. In addition, 5 patients undergoing primary TAA served as a control group. Radiologically, patients were classified into those with ballooning osteolysis and those without, according to defined criteria. Histomorphometric, immunohistochemical, and elemental analysis of tissues was performed. Von Kossa staining and digital microscopy was performed on all tissue samples. Results - Patients without ballooning osteolysis showed a generally higher expression of lymphocytes, and CD3+, CD11c+, CD20+, and CD68+ cells in a perivascular distribution, compared to diffuse expression. The odds of having ballooning osteolysis was 300 times higher in patients with calcium content >0.5 mg/g in periprosthetic tissue than in patients with calcium content ≤0.5 mg/g (p < 0.001). Interpretation - There have been very few studies investigating the pathomechanisms of failed TAA and the cause-effect nature of ballooning osteolysis in this context. Our data suggest that the hydroxyapatite coating of the implant may be a contributory factor.

  13. Restenosis following balloon dilation of benign esophageal stenosis

    Institute of Scientific and Technical Information of China (English)

    Ying-Sheng Cheng; Ming-Hua Li; Ren-Jie Yang; Hui-Zhen Zhang; Zai-Xian Ding; Qi-Xin Zhuang; Zhi-Ming Jiang; Ke-Zhong Shang

    2003-01-01

    AIM: To elucidate the mechanism of restenosis following balloon dilation of benign esophageal stenosis.METHODS: A total of 49 rats with esophageal stenosis were induced in 70 rats using 5 ml of 50 % sodium hydroxide solution and the double-balloon method, and an esophageal restenosis (RS) model was developed by esophageal stenosis using dilation of a percutaneous transluminal coronary angioplasty (PTCA) balloon catheter. These 49 rats were divided into two groups: rats with benign esophageal stricture caused by chemical burn only (control group, n=21) and rats with their esophageal stricture treated with balloon catheter dilation (experimental group, n=28). Imaging analysis and immunohistochemistry were used for both quantitative and qualitative analyses of esophageal stenosis and RS formation in the rats, respectively.RESULTS: Cross-sectional areas and perimeters of the esophageal mucosa layer, muscle layer, and the entire esophageal layers increased significantly in the experimental group compared with the control group. Proliferating cell nuclear antigen (PCNA) was expressed on the 5th day after dilation, and was still present at 1 month. Fibronectin (FN)was expressed on the 1st day after dilation, and was still present at 1 month.CONCLUSION: Expression of PCNA and FN plays an important role in RS after balloon dilation of benign esophageal stenosis.

  14. Stratospheric balloons from Esrange - current and future capabilities

    Science.gov (United States)

    Norberg, O.

    Stratospheric balloon operations have been carried out at the Swedish Space Corporation's rocket, balloon and satellite operations base Esrange since 1974; approximately 550 stratospheric balloons have been launched during this period. The facility, located in northern Sweden at 68 degrees north, is fully equipped with a large launch pad, payload and flight train preparation hangars, telemetry stations, recovery helicopters, and supporting infrastructure. Many of the scientific balloons launched are CNES missions. This paper will present the possibilities for scientific and technical balloon missions at high latitudes and with a vast landing area in northern Sweden, Finland, and Russia. The proximity to the Arctic polar vortex makes Esrange an ideal base for studies of for example the ozone destruction process in the Arctic. A new option proposed by the Swedish Space Corporation and NASA is to perform week-long missions from the south of Sweden to western Canada. A newly developed line-of-sight telemetry system, E-LINK, for high bit-rates (> 2 Mbps both downlink and uplink) and based on the Ethernet communication standard is also described.

  15. Treatment strategies for extensive chronic SFA occlusions: indications and results.

    NARCIS (Netherlands)

    Lensvelt, M.M.A.; Reijnen, M.M.P.J.; Wallis de Vries, B.M.; Zeebregts, C.J.A.

    2012-01-01

    Treatment modalities for extensive chronic occlusive disease of the superficial femoral artery (SFA) have changed during the last decades. In this chapter we provide an overview of current treatment modalities for extensive chronic occlusive disease of the SFA. Although the autologous venous conduit

  16. Treatment strategies for extensive chronic SFA occlusions : indications and results

    NARCIS (Netherlands)

    Lensvelt, M. M. A.; Reijnen, M. M. P. J.; De Vries, B. M. Wallis; Zeebregts, C. J.

    2012-01-01

    Treatment modalities for extensive chronic occlusive disease of the superficial femoral artery (SFA) have changed during the last decades. In this chapter we provide an overview of current treatment modalities for extensive chronic occlusive disease of the SFA. Although the autologous venous conduit

  17. An adaptive occlusion culling algorithm for use in large ves

    DEFF Research Database (Denmark)

    Bormann, Karsten

    2000-01-01

    The Hierarchical Occlusion Map algorithm is combined with Frustum Slicing to give a simpler occlusion-culling algorithm that more adequately caters to large, open VEs. The algorithm adapts to the level of visual congestion and is well suited for use with large, complex models with long mean free...

  18. Dorzolamide increases retinal oxygen tension after branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Noergaard, Michael Hove; Bach-Holm, Daniella; Scherfig, Erik;

    2008-01-01

    To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs.......To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs....

  19. Comorbidity in patients with branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Bertelsen, Mette; Linneberg, Allan René; Rosenberg, Niels Thomas;

    2012-01-01

    To evaluate comorbidity before and after the diagnosis of branch retinal vein occlusion to determine whether it is a consequence of arterial thickening and therefore could serve as a diagnostic marker for other comorbidities and to evaluate the risk factors for the development of such occlusion....

  20. Early rethrombosis in femoropopliteal occlusions treated with percutaneous transluminal angioplasty

    DEFF Research Database (Denmark)

    Jørgensen, B; Meisner, S; Holstein, P;

    1990-01-01

    One hundred and thirty-seven consecutive percutaneous transluminal angioplasties (PTA) were performed for femoropopliteal vascular disease including 58 stenoses and 79 total occlusions. Nine occlusions could not be crossed with the guidewire, but in the remaining 128 the haemodynamic and clinical...

  1. Occlusion and functional disorders of the masticatory system.

    Science.gov (United States)

    Okeson, J P

    1995-04-01

    Understanding the relationship between occlusion and functional disorders of the masticatory system is no easy task. This article explores the static, functional, and dynamic relationships of the occlusal condition to the signs and symptoms of masticatory dysfunction. Some possible relationships are discussed.

  2. Cognitive impairments in patients with cerebrovascular steno-occlusive disease

    Institute of Scientific and Technical Information of China (English)

    石丹

    2012-01-01

    Objective To explore the relationship between cerebrovascular steno-occlusive disease and neuropsychological performance by cognitive function assessment. Methods Using a case-control study,45 patients with cerebrovascular steno-occlusive lesions (patient group) and 59 control subjects without cerebrovascular

  3. Relationship between retinal vascular occlusions and incident cerebrovascular diseases

    Science.gov (United States)

    Zhou, Yue; Zhu, Wengen; Wang, Changyun

    2016-01-01

    Abstract Several studies investigating the role of retinal vascular occlusions, on cerebrovascular diseases (CVD) have been reported, but the results are still inconsistent. We therefore sought to evaluate the relationship between retinal vascular occlusions and CVD. We systematically searched the Cochrane Library, PubMed, and ScienceDirect databases through January 31, 2016 for studies evaluating the effect of retinal vascular occlusions on the risk of CVD. Data were abstracted using predefined criteria, and then pooled by RevMan 5.3 software. A total of 9 retrospective studies were included in this meta-analysis. When compared with individuals without retinal vascular occlusions, both individuals with retinal artery occlusion (RAO) (odds ratio [OR] = 2.01, 95% confidence interval [CI]: 1.21–3.34; P = 0.005) and individuals with retinal vein occlusion (RVO) (OR = 1.37, 95% CI: 1.24–1.50; P < 0.00001) had higher risks of developing CVD. Additionally, both individuals with central retinal artery occlusion (CRAO) (OR = 2.00, 95% CI: 1.12–3.56; P = 0.02) and branch retinal artery occlusion (BRAO) (OR = 1.60, 95% CI: 1.03–1.48; P = 0.04) were significantly associated with increased risk of CVD. Published literatures support both RVO and RAO are associated with increased risks of CVD. Further prospective studies are needed to confirm these findings. PMID:27368050

  4. The impact of numeric and graphic displays of ST-segment deviation levels on cardiologists' decisions of reperfusion therapy for patients with acute coronary occlusion.

    Science.gov (United States)

    Nimmermark, Magnus O; Wang, John J; Maynard, Charles; Cohen, Mauricio; Gilcrist, Ian; Heitner, John; Hudson, Michael; Palmeri, Sebastian; Wagner, Galen S; Pahlm, Olle

    2011-01-01

    The study purpose is to determine whether numeric and/or graphic ST measurements added to the display of the 12-lead electrocardiogram (ECG) would influence cardiologists' decision to provide myocardial reperfusion therapy. Twenty ECGs with borderline ST-segment deviation during elective percutaneous coronary intervention and 10 controls before balloon inflation were included. Only 5 of the 20 ECGs during coronary balloon occlusion met the 2007 American Heart Association guidelines for ST-elevation myocardial infarction (STEMI). Fifteen cardiologists read 4 sets of these ECGs as the basis for a "yes/no" reperfusion therapy decision. Sets 1 and 4 were the same 12-lead ECGs alone. Set 2 also included numeric ST-segment measurements, and set 3 included both numeric and graphically displayed ST measurements ("ST Maps"). The mean (range) positive reperfusion decisions were 10.6 (2-15), 11.4 (1-19), 9.7 (2-14), and 10.7 (1-15) for sets 1 to 4, respectively. The accuracies of the observers for the 5 STEMI ECGs were 67%, 69%, and 77% for the standard format, the ST numeric format, and the ST graphic format, respectively. The improved detection rate (77% vs 67%) with addition of both numeric and graphic displays did achieve statistical significance (P numeric and/or graphic displays. Acute coronary occlusion detection rate was low for ECGs meeting STEMI criteria, and this was improved by adding ST-segment measurements in numeric and graphic forms. These results merit further study of the clinical value of this technique for improved acute coronary occlusion treatment decision support.

  5. [Single- and multi-unit fixed dental prostheses in relation to the occlusal system

    NARCIS (Netherlands)

    Witter, D.J.; Gerritsen, A.E.; Spijker, A. van 't; Creugers, N.H.J.

    2013-01-01

    Occlusion concepts based on functional aspects offer more solid ground in the diagnostic process and in the treatment of (reduced) dentitions than morphologically and mechanically oriented occlusion concepts. Nevertheless, for occlusal reconstruction morphologically oriented guidelines are necessary

  6. Clinical application of hepatic venous occlusion for hepatectomy

    Institute of Scientific and Technical Information of China (English)

    PAN Ze-ya; YANG Yuan; ZHOU Wei-ping; LI Ai-jun; FU Si-yuan; WU Meng-chao

    2008-01-01

    Background Most liver resections require clamping of the hepatic pedicle (Pringle maneuver) to avoid excessive blood loss. But Pringle maneuver can not control backflow bleeding of hepatic vein, Resection of liver tumors involving hepatic veins may cause massive hemorrhage or air embolism from the injuries of the hepatic veins. Although total hepatic vascular exclusion can prevent bleeding of the hepatic veins effectively, it also may result in systemic hemodynamic disturbance because of the inferior vena cava being clamped. Hepatic venous occlusion, a new technique, can control the inflow and outflow of the liver without clamping the vena cava.Methods A total of 71 cases of liver tumors underwent resection with occlusion of more than one of the main hepatic veins. All tumors involved the second porta hepatis and at least one main hepatic vein. Ligation or occlusion with serrefines, tourniquets and auricular clamps were used in hepatic venous occlusion.Results Of the 71 patients, ligation of the hepatic veins was used in 28 cases, occlusion with a tourniquet in 26, and occlusion with a serrefine in 17. Right hepatic veins were occluded in 38 cases, both right and middle hepatic veins in 2,the common trunk of the left and middle hepatic veins in 24, branches of the left and middle hepatic veins in 2, and all three hepatic veins in 5. Thirty-five cases underwent hemihepatic vascular occlusion, 4 alternate hemihepatic vascular occlusion, 23 portal triad clamping plus selective hepatic vein occlusion, and 9 portal triad clamping plus total hepatic vein occlusion. The third porta hepatis was isolated in 26 cases. The amount of intraoperative blood loss averaged (540±283) (range 100 to 1000) ml in the group of total hemihepatic vascular occlusion and in the group of alternate hemihepatic vascular occlusion, (620±317) (range 200-6000) ml in the group of portal triad clamping plus selective or total hepatic vein occlusion. All tumors were completely removed

  7. Tardive dyskinesia affected by occlusal treatment--a case report.

    Science.gov (United States)

    Kai, S; Kai, H; Tashiro, H

    1994-07-01

    The following is a case report of occlusal treatment for involuntary mandibular movement occurring in a 79-year old woman. This was diagnosed as sulpiride-induced tardive dyskinesia. The patient had been treated with sulpiride to improve gastrointestinal symptoms for five years until the onset of involuntary mandibular movement. The involuntary movement worsened even after discontinuation of the drug for 10 weeks. The dyskinesia improved in the course of treatment with an occlusal splint placed over her upper denture. After wearing the new denture with increased occlusal vertical dimension, the dyskinesia disappeared almost completely. Sirognathographic observation showed that previous denture wear evoked remarkable involuntary movement of the mandible once again. It is uncertain whether such improvement may result from discontinuation of the drug or from the occlusal treatment. However, it appears that occlusal factors played an important role in orofacial manifestation of tardive dyskinesia (TD) in this case.

  8. The Electroretinogram in Patients with Retinal Vascular Occlusion

    Institute of Scientific and Technical Information of China (English)

    Shizhou Huang; Lezheng Wu; Taiqing Luo; De-Zheng Wu; Futian Jiang; Guangwei Luo; Juanmei Ma

    2001-01-01

    Purpose: to measure and analyze the electroretinogram (ERG) in patients with retinal vascular occlusion. Method: fifty-eight cases (59 eyes) of retinal vascular occlusion and the fellow eyes of 47 cases were tested with Ganzfeld ERG. The scotopic and photopic ERG, and oscillatory potentials were tested according to the ERG standard of ISCEV. Results: The abnormal rates of Ops and b wave were higher in retinal vascular occlusion. The abnormal ERG appeared mostly in CRVO among four types of retinal vascular occlusion. The comparisons of some amplitudes and latencies between the fellow eyes and the affected eyes showed statistically significant difference. Conclusion: The oscillatory potentials and b waves have important roles in evaluating the retinal function of patients with retinal vascular occlusions. There are some clinical significance for comparing ERG between the affected eye and the fellow eye. Eye Science 2001; 17: 50 ~ 53.

  9. Ideal ballooning modes, shear flow and the stable continuum

    Science.gov (United States)

    Taylor, J. B.

    2012-11-01

    There is a well-established theory of ballooning modes in a toroidal plasma. The cornerstone of this is a local eigenvalue λ on each magnetic surface—which also depends on the ballooning phase angle k. In stationary plasmas, λ(k) is required only near its maximum, but in rotating plasmas its average over k is required. Unfortunately in many cases λ(k) does not exist for some range of k, because the spectrum there contains only a stable continuum. This limits the application of the theory, and raises the important question of whether this ‘stable interval’ gives rise to significant damping. This question is re-examined using a new, simplified, model—which leads to the conclusion that there is no appreciable damping at small shear flow. In particular, therefore, a small shear flow should not affect ballooning mode stability boundaries.

  10. Ideal MHD Ballooning modes, shear flow and the stable continuum

    CERN Document Server

    Taylor, J B

    2012-01-01

    There is a well established theory of Ballooning modes in a toroidal plasma. The cornerstone of this is a local eigenvalue lambda on each magnetic surface - which also depends on the ballooning phase angle k. In stationary plasmas lambda(k) is required only near its maximum, but in rotating plasmas its average over k is required. Unfortunately in many case lambda(k) does not exist for some range of k, because the spectrum there contains only a stable continuum. This limits the application of the theory, and raises the important question of whether this "stable interval" gives rise to significant damping. This question is re-examined using a new, simplified, model - which leads to the conclusion that there is no appreciable damping at small shear flow. In particular, therefore, a small shear flow should not affect Ballooning mode stability boundaries.

  11. Tokamak resistive magnetohydrodynamic ballooning instability in the negative shear regime

    Institute of Scientific and Technical Information of China (English)

    Shi Bing-Ren; Lin Jian-Long; Li Ji-Quan

    2007-01-01

    Improved confinement of tokamak plasma with central negative shear is checked against the resistive ballooning mode. In the negative shear regime, the plasma is always unstable for purely growing resistive ballooning mode. For a simplest tokamak equilibrium model, the s-α model, characteristics of this kind of instability are fully clarified by numerically solving the high n resistive magnetohydrodynamic ballooning eigen-equation. Dependences of the growth rate on the resistivity, the absolute shear value, the pressure gradient are scanned in detail. It is found that the growth rate is a monotonically increasing function of a while it is not sensitive to the changes of the shear s, the initial phase θ0 and the resistivity parameter εR.

  12. Iridium: Global OTH data communications for high altitude scientific ballooning

    Science.gov (United States)

    Denney, A.

    While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several

  13. Gastroesophageal reflux diagnosed by occlusal splint tintion.

    Science.gov (United States)

    Cebrián-Carretero, José Luis; López-Arcas-Calleja, José María

    2006-01-01

    The gastroesophageal reflux (GER) disease is a very frequent digestive disorder, mainly characterised by the reflux of the gastric acidic content to the esophage in abnormal quantities. There are different situations that favour this situation but almost in all of them rely an incompetence of the esophagic sphincter. The clinical consequences are many, including oral manifestations. Among all of them the most frequent is the esophagitis followed by symptoms at the pharynx or larynx and finally, the oral cavity. At this level fundamentally we will find enamel and oral mucosa erosions. We report the case of a patient who was indirectly diagnosed of her esophague disease by the observation of the alterations in the occlusal splint induced by the gastric reflux. We review the literature concerning the above topic and its possible association with the miofascial syndrome.

  14. Pathology of Coronary Chronic Total Occlusion

    Directory of Open Access Journals (Sweden)

    Kenichi Sakakura

    2016-06-01

    Full Text Available There is an increasing need for percutaneous revascularization procedures of coronary Chronic Total Occlusion (CTO, because many patients with severe coronary artery disease have limited options for revascularization. Although the success rate of percutaneous revascularization of CTOs was unsatisfactory from the 1990s to the 2000s, recent technological advances in interventional strategies have improved the success rate to 85%. Detailed histological assessment of human autopsy studies of CTO has contributed significantly to the refinement in Percutaneous Coronary Intervention (PCI techniques and device development. We have recently reported the pathological findings and characteristics of CTOs that occur in different clinical scenarios. In this review, we discuss the pathology of CTOs to facilitate greater understanding of revascularization strategies for CTOs.

  15. The role of uninhibited occlusal development.

    Science.gov (United States)

    Rabine, M

    1978-07-01

    Stage A treatment is compatible with contemporary orthodontic treatment. 1. It allows for free and uninhibited occlusal development. 2. It gives the orthodontist and opportunity to make a meaningful diagnosis. 3. It does not inhibit the natural inherent forces of growth and development from expressing themselves within the individual patient. 4. It establishes the position of the lower anterior teeth by their self-alignment. 5. It enables the orthodontists to predict the stability of treatment. 6. It simplifies the treatment when Stage I commences. 7. It helps in developing a good rapport between patient, parent, and orthodontist. Just as Caesar wrote of Gaul in his day, "Omnia [Begg] divisaest in partes tres ... "--Stage I, Stage II, and Stage III. I would like to suggest that new province has been added: Stage A--it being the prelude to the accepted three stages in Begg treatment or any appliance treatment of the past.

  16. Local histograms and image occlusion models

    CERN Document Server

    Massar, Melody L; Fickus, Matthew; Kovacevic, Jelena

    2011-01-01

    The local histogram transform of an image is a data cube that consists of the histograms of the pixel values that lie within a fixed neighborhood of any given pixel location. Such transforms are useful in image processing applications such as classification and segmentation, especially when dealing with textures that can be distinguished by the distributions of their pixel intensities and colors. We, in particular, use them to identify and delineate biological tissues found in histology images obtained via digital microscopy. In this paper, we introduce a mathematical formalism that rigorously justifies the use of local histograms for such purposes. We begin by discussing how local histograms can be computed as systems of convolutions. We then introduce probabilistic image models that can emulate textures one routinely encounters in histology images. These models are rooted in the concept of image occlusion. A simple model may, for example, generate textures by randomly speckling opaque blobs of one color on ...

  17. To sail the skies of Mars - Scientific ballooning on the red planet

    Science.gov (United States)

    Gaidos, Eric J.; Burke, James D.

    1988-01-01

    Balloons represent a novel approach to exploring the surface of Mars. One promising aerostat system incorporates a solar-powered balloon as a means of generating diurnally varying lift and so can 'hop' across the surface, obtaining detailed information at a large number of sites. Two important areas of research and testing are underway on solar balloon technology and balloon payload design. The solar balloon concept has been demonstrated on earth, but more work is needed on a 'flyable' version for Mars. Particular attention must be paid to radiation heat transfer and aerodynamic effects. A special 'snake' payload concept has been demonstrated that allows for balloon system traverses of the surface and provides a usable instrument platform. A balloon system of this type could obtain unique surface imaging and physical and chemical data. The flight of the balloon also provides in situ atmospheric boundary-layer and circulation measurements.

  18. Balloon vetebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures

    NARCIS (Netherlands)

    Verlaan, JJ; van Helden, WH; Oner, FC; Verbout, AJ; Dhert, WJA

    2002-01-01

    Study Design. A human cadaveric model was used to evaluate balloon vertebroplasty in traumatic vertebral fractures. Objectives. To assess the feasibility and safety of balloon vertebroplasty followed by calcium phosphate cement augmentation to prevent recurrent kyphosis. Summary of Background Data.

  19. Matrix metalloproteinase inhibition reduces adventitial thickening and collagen accumulation following balloon dilation

    NARCIS (Netherlands)

    Sierevogel, MJ; Velema, E; van der Meer, FJ; Nijhuis, MO; de Kleijn, DPV; Borst, C; Pasterkamp, G

    2002-01-01

    Objective: Constrictive arterial remodeling following balloon angioplasty has been related to adventitial collagen accumulation and subsequent thickening and can be prevented by matrix ructalloprotemase (MMP) inhibition. Following balloon dilation, we examined the effect of MMP inhibition on colla-e

  20. Thrombophilic screening in retinal artery occlusion patients

    Directory of Open Access Journals (Sweden)

    Valeria Nagy

    2008-10-01

    Full Text Available Valeria Nagy1, Lili Takacs1, Zita Steiber1, György Pfliegler2, Andras Berta11Department of Ophthalmology, 2Division of Rare Diseases, University of Debrecen Medical and Health Science Center, Debrecen, HungaryBackground: Retinal artery occlusion (RAO is an ischemic vascular damage of the retina, which frequently leads to sudden, mostly irreversible loss of vision. In this study, blood thrombophilic factors as well as cardiovascular risk factors were investigated for their relevance to this pathology. Thrombophilic risk factors so far not evaluated were included in the study.Patients and methods: 28 RAO patients and 81 matched control subjects were examined. From blood samples, protein C, protein S, antithrombinopathy, and factor V (Leiden mutation (FV, factor II gene polymorphism, factor VIII C level, plasminogen activity, lipoprotein(a and fibrinogen levels, hyperhomocysteinemia and presence of anticardiolipin – antiphospholipid antibodies were investigated. Possibly relevant pathologies such as diabetes mellitus, hypertension, and ischemic heart disease were also registered. Statistical analysis by logistic regression was performed with 95% confidence intervals.Results: In the group of patients with RAO only the incidence of hypertension (OR: 3.33, 95% CI: 1.30–9.70, p = 0.014 as an average risk factor showed significant difference, but thrombophilic factors such as hyperfibrinogenemia (OR: 2.9, 95% CI: 1.29–6.57, p = 0.010 and the presence of FV (Leiden mutation (OR: 3.9, 95% CI: 1.43–10.96, p = 0.008 increased the chances of developing this disease.Conclusions: Our results support the assumption that thrombophilia may contribute to the development of RAO besides vascular damage due to the presence of cardiovascular risk factors. Further studies are needed, however, to justify the possible use of secondary prophylaxis in form of anticoagulant/antiplatelet therapy.Keywords: retinal arterial occlusion, risk factors, thrombophilia

  1. Evolution of NASA Scientific Ballooning and Particle Astrophysics Research

    Science.gov (United States)

    Jones, William Vernon

    2017-01-01

    Particle astrophysics research has a history in ballooning that spans over 100 years, ever since Victor Hess discovered cosmic rays on a manned balloon in 1912. The NASA Particle Astrophysics Program currently covers the origin, acceleration and transport of Galactic cosmic rays, plus the Nature of Dark Matter and Ultrahigh Energy Neutrinos. Progress in each of these topics has come from sophisticated instrumentation flown on Long Duration Balloon (LDB) flights around Antarctica for more than two decades. Super Pressure Balloons (SPB) and International Space Station (ISS) platforms are emerging opportunities that promise major steps forward for these and other objectives. NASA has continued development and qualification flights leading to SPB flights capable of supporting 1000 kg science instruments to 33 km for upwards of hundred day missions, with plans for increasing the altitude to 38 km. This goal is even more important now, in view of the Astro2010 Decadal Study recommendation that NASA should support Ultra-Long Duration Balloon (ULDB) flight development for studies of particle astrophysics, cosmology and indirect detection of dark matter. The mid-latitude test flight of an 18.8 MCF SPB launched from Wanaka, NZ in 2015 achieved 32 days of nearly constant altitude exposure, and an identical SPB launched from Wanaka in 2016 with a science payload flew for 46 days. Scientific ballooning as a vital infrastructure component for cosmic ray and general astrophysics investigations, including training for young scientists, graduate and undergraduate students, leading up to the 2020 Decadal Study and beyond, will be presented and discussed.

  2. Near Space Lab-Rat Experimentation using Stratospheric Balloon

    Science.gov (United States)

    Buduru, Suneel Kumar; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Trivedi, Dharmesh; Devarajan, Anand; Pandit Manikrao Kulkarni, MR..; Ojha, Devendra; Korra, Sakram; Neerudu, Nagendra; Seng, Lim; Godi, Stalin Peter

    2016-07-01

    First ever balloon borne lab-rat experiment up to near space stratospheric altitude levels carried out at TIFR Balloon Facility, Hydeabad using zero pressure balloons for the purpose of validating the life support system. A series of two balloon experiments conducted under joint collaboration with IN.Genius, Singapore in the year 2015. In these experiments, three lab-rats sent to stratosphere in a pressurized capsule designed to reach an altitude of 30 km by keeping constant pressure, temperature and maintained at a precise rate of oxygen supply inside the capsule. The first experiment conducted on 1 ^{st} February, 2015 with a total suspended weight of 225 kg. During the balloon ascent stage at 18 km altitude, sensors inside the capsule reported drastic drop in internal pressure while oxygen and temperatures maintained at correct levels resulted in premature fligt termination at 20.1 km. All the three lab-rats recovered without life due to the collapse of their lungs caused by the depressurization inside the capsule. The second experiment conducted on 14th March, 2015 using a newly developed capsule with rectification of depressurization fault by using improved sealing gaskets and hermitically sealed connectors for sending lab-rats again to stratosphere comprising a total suspended load of 122.3 kg. The balloon flight was terminated after reaching 29.5 km in 110 minutes and succesfully recovered all the three lab-rats alive. This paper focuses on lessons learnt of the development of the life support system as an integral pressurized vessel, flight control instrumentation, flight simulation tests using thermo-vaccum chamber with pre-flight operations.

  3. Paclitaxel-coated balloons - Survey of preclinical data.

    Science.gov (United States)

    Schnorr, B; Kelsch, B; Cremers, B; Clever, Y P; Speck, U; Scheller, B

    2010-10-01

    Restenosis following interventions in the coronary or peripheral arteries develops over weeks to months. In coronary arteries the restenosis rate has been markedly reduced since the advent of drug-eluting stents. Non-stent-based methods for local drug delivery enable restenosis inhibition without the need for stent implantation, does not permanently change the structure of the vessel, are repeatable, and seems to be applicable where drug-eluting stents provide insufficient protection. Preclinical data indicate that short exposure of the vessel wall to a lipophilic inhibitor of cell proliferation is sufficient for preventing restenosis. Initial evidence to this effect emerged from an investigation of paclitaxel embedded in a matrix that enhances the solubility and release of the agent from the balloon coating as well as its transfer to the vessel wall. Further corroborating data from preclinical and clinical studies demonstrating a reduction in late lumen loss and lower restenosis rates led to the market introduction of a variety of paclitaxel-coated angioplasty balloons. The effectiveness of restenosis inhibition is not determined by the active agent alone. Other factors that are crucial for the effectiveness and safety of drug-coated angioplasty balloons are the formulation containing the agent and the coating technique. In this review we first outline the development of paclitaxel-coated balloons to then provide an overview of the preclinical results obtained with different paclitaxel-coated balloons and finally compare these with the outcome in patients. The article concludes with a short outlook on initial results with a zotarolimus-coated angioplasty balloon.

  4. Second-generation endometrial ablation technologies: the hot liquid balloons.

    Science.gov (United States)

    Vilos, George A; Edris, Fawaz

    2007-12-01

    Hysteroscopic endometrial ablation (HEA) was introduced in the 1980s to treat menorrhagia. Its use required additional training, surgical expertise and specialized equipment to minimize emergent complications such as uterine perforations, thermal injuries and excessive fluid absorption. To overcome these difficulties and concerns, thermal balloon endometrial ablation (TBEA) was introduced in the 1990s. Four hot liquid balloons have been introduced into clinical practice. All systems consist of a catheter (4-10mm diameter), a silicone balloon and a control unit. Liquids used to inflate the balloons include internally heated dextrose in water (ThermaChoice, 87 degrees C), and externally heated glycine (Cavaterm, 78 degrees C), saline (Menotreat, 85 degrees ) and glycerine (Thermablate, 173 degrees C). All balloons require pressurization from 160 to 240 mmHg for treatment cycles of 2 to 10 minutes. Prior to TBEA, preoperative endometrial thinning, including suction curettage, is optional. Several RCTs and cohort studies indicate that the advantages of TBEA include portability, ease of use and short learning curve. In addition, small diameter catheters requiring minimal cervical dilatation (5-7 mm) and short duration of treatment cycles (2-8 min) allow treatment under minimal analgesia/anesthesia requirements in a clinic setting. Following TBEA serious adverse events, including thermal injuries to viscera have been experienced. To minimize such injuries some surgeons advocate the use of routine post-dilatation hysteroscopy and/or ultrasonography to confirm correct intrauterine placement of the balloon prior to initiating the treatment cycle. After 10 years of clinical practice, TBEA is thought to be the preferred first-line surgical treatment of menorrhagia in appropriately selected candidates. Economic modeling also suggested that TBEA may be more cost-effective than HEA.

  5. Balloon-Borne Infrasound Detection of Energetic Bolide Events

    Science.gov (United States)

    Young, Eliot F.; Ballard, Courtney; Klein, Viliam; Bowman, Daniel; Boslough, Mark

    2016-10-01

    Infrasound is usually defined as sound waves below 20 Hz, the nominal limit of human hearing. Infrasound waves propagate over vast distances through the Earth's atmosphere: the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization) has 48 installed infrasound-sensing stations around the world to detect nuclear detonations and other disturbances. In February 2013, several CTBTO infrasound stations detected infrasound signals from a large bolide that exploded over Chelyabinsk, Russia. Some stations recorded signals that had circumnavigated the Earth, over a day after the original event. The goal of this project is to improve upon the sensitivity of the CTBTO network by putting microphones on small, long-duration super-pressure balloons, with the overarching goal of studying the small end of the NEO population by using the Earth's atmosphere as a witness plate.A balloon-borne infrasound sensor is expected to have two advantages over ground-based stations: a lack of wind noise and a concentration of infrasound energy in the "stratospheric duct" between roughly 5 - 50 km altitude. To test these advantages, we have built a small balloon payload with five calibrated microphones. We plan to fly this payload on a NASA high-altitude balloon from Ft Sumner, NM in August 2016. We have arranged for three large explosions to take place in Socorro, NM while the balloon is aloft to assess the sensitivity of balloon-borne vs. ground-based infrasound sensors. We will report on the results from this test flight and the prospects for detecting/characterizing small bolides in the stratosphere.

  6. Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.

    Science.gov (United States)

    Ro, Andrew J; Davé, Vipul

    2013-03-01

    Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons.

  7. Early Results with the Use of Heparin-bonded Stent Graft to Rescue Failed Angioplasty of Chronic Femoropopliteal Occlusive Lesions: TASC D Lesions Have a Poor Outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kuhan, Ganesh, E-mail: gkuhan@nhs.net; Abisi, Said; Braithwaite, Bruce D.; MacSweeney, Shane T. R. [Nottingham University Hospitals, Vascular and Endovascular Unit, Queens Medical Centre (United Kingdom); Whitaker, Simon C.; Habib, Said B. [Nottingham University Hospitals, Department of Radiology, Queen' s Medical Centre (United Kingdom)

    2012-10-15

    Purpose: To evaluate early patency rate of the heparin-bonded stent grafts in atherosclerotic long femoropopliteal occlusive disease, and to identify factors that affect outcome. Methods: Heparin-bonded Viabahn stent grafts were placed in 33 limbs in 33 patients during 2009-2010. The stents were deployed to rescue failed conventional balloon angioplasty. Mean age was 69 (range 44-88) years, and 67 % (22 of 33) were men. Most procedures (21 of 33, 64 %) were performed for critical limb ischemia (33 % for rest pain, 30 % tissue loss). Kaplan-Meier plots and Cox regression analysis were used to identify significant risk factors. Results: The average length of lesions treated was 25 {+-} 10 cm, and they were predominantly TASC (Transatlantic Intersociety Consensus) D (n = 13) and C (n = 17) lesions. The median primary patency was 5.0 months (95 % confidence interval 1.22-8.77). The mean secondary patency was 8.6 months (95 % confidence interval 6.82-10.42). Subsequently, 4 patients underwent bypass surgery and 5 patients underwent major amputation. One patient died. There were 5 in-stent or edge-stent stenoses. Cox multivariate regression analysis identified TASC D lesions to be a significant risk factor for early occlusion (p = 0.035). Conclusion: TASC D lesions of femoropopliteal occlusions have poor patency rates with the use of heparin-bonded stent grafts after failed conventional angioplasty. Alternative options should be considered for these patients.

  8. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  9. AIAA Educator Academy: The Space Weather Balloon Module

    Science.gov (United States)

    Longmier, B.; Henriquez, E.; Bering, E. A.; Slagle, E.

    2013-12-01

    Educator Academy is a K-12 STEM curriculum developed by the STEM K-12 Outreach Committee of the American Institute of Aeronautics and Astronautics (AIAA). Consisting of three independent curriculum modules, K-12 students participate in inquiry-based science and engineering challenges to improve critical thinking skills and enhance problem solving skills. The Space Weather Balloon Curriculum Module is designed for students in grades 9-12. Throughout this module, students learn and refine physics concepts as well as experimental research skills. Students participate in project-based learning that is experimental in nature. Students are engaged with the world around them as they collaborate to launch a high altitude balloon equipped with HD cameras.The program leaders launch high altitude weather balloons in collaboration with schools and students to teach physics concepts, experimental research skills, and to make space exploration accessible to students. A weather balloon lifts a specially designed payload package that is composed of HD cameras, GPS tracking devices, and other science equipment. The payload is constructed and attached to the balloon by the students with low-cost materials. The balloon and payload are launched with FAA clearance from a site chosen based on wind patterns and predicted landing locations. The balloon ascends over 2 hours to a maximum altitude of 100,000 feet where it bursts and allows the payload to slowly descend using a built-in parachute. The payload is located using the GPS device. In April 2012, the Space Weather Balloon team conducted a prototype field campaign near Fairbanks Alaska, sending several student-built experiments to an altitude of 30km, underneath several strong auroral displays. To better assist teachers in implementing one or more of these Curriculum Modules, teacher workshops are held to give teachers a hands-on look at how this curriculum is used in the classroom. And, to provide further support, teachers are each

  10. Balloon-Borne System Would Aim Instrument Toward Sun

    Science.gov (United States)

    Polites, M. E.

    1992-01-01

    Proposed system including digital control computer, control sensors, and control actuators aims telescope or other balloon-borne instrument toward Sun. Pointing system and instrument flown on gondola, suspended from balloon. System includes reaction wheel, which applies azimuthal control torques to gondola, and torque motor to apply low-frequency azimuthal torques between gondola and cable. Three single-axis rate gyroscopes measure yaw, pitch, and roll. Inclinometer measures roll angle. Two-axis Sun sensor measures deviation, in yaw and pitch, of attitude of instrument from line to apparent center of Sun. System provides initial coarse pointing, then maintains fine pointing.

  11. Intrauterine tamponade balloon use in the treatment of uterine inversion.

    Science.gov (United States)

    Haeri, Sina; Rais, Sheliza; Monks, Brian

    2015-01-06

    Uterine inversion is a rare but life-threatening obstetrical emergency that occurs when the fundus of the uterus prolapses through the cervix, hence turning the uterus inside out. In this case report, we present our experience using an intrauterine tamponade balloon for management of uterine inversion, and a review of the literature. The utility of an intrauterine tamponade balloon in cases of uterine inversion, especially when maternal medical conditions preclude the use of uterotonics, or reinversion is observed should be kept in mind.

  12. Cosmic ray abundance measurements with the CAKE balloon experiment

    CERN Document Server

    Cecchini, S; Giacomelli, G; Manzoor, S; Medinaceli, E; Patrizii, L; Togo, V

    2005-01-01

    We present the results from the CAKE (Cosmic Abundance below Knee Energy) balloon experiment which uses nuclear track detectors. The final experiment goal is the determination of the charge spectrum of CR nuclei with Z $>$ 30 in the primary cosmic radiation. The detector, which has a geometric acceptance of $\\sim$ 1.7 m$^2$sr, was exposed in a trans-mediterranean stratospheric balloon flight. Calibrations of the detectors used (CR39 and Lexan), scanning strategies and algorithms for tracking particles in an automatic mode are presented. The present status of the results is discussed

  13. Simultaneous electric-field measurements on nearby balloons.

    Science.gov (United States)

    Mozer, F. S.

    1972-01-01

    Electric-field payloads were flown simultaneously on two balloons from Great Whale River, Canada, on September 21, 1971, to provide data at two points in the upper atmosphere that differed in altitude by more than one atmospheric density scale height and in horizontal position by 30-140 km. The altitude dependences in the two sets of data prove conclusively that the vertical electric field at balloon altitudes stems from fair-weather atmospheric electricity sources and that the horizontal fields are mapped down ionospheric fields, since the weather-associated horizontal fields were smaller than 2 mV/m.

  14. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    Science.gov (United States)

    2010-01-01

    Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs). However, a recent report described a discrepancy between the habitual occlusal position (HOP) and the bite plate-induced occlusal position (BPOP) and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP) as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI) and the Helkimo Clinical Dysfunction Index (CDI) before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p 0.1). Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted. PMID:20346167

  15. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    Directory of Open Access Journals (Sweden)

    Chiwata Ichiro

    2010-03-01

    Full Text Available Abstract Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs. However, a recent report described a discrepancy between the habitual occlusal position (HOP and the bite plate-induced occlusal position (BPOP and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI and the Helkimo Clinical Dysfunction Index (CDI before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p 0.1. Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted.

  16. BioEnterics Intragastric Balloon (BIB) versus Spatz Adjustable Balloon System (ABS): Our experience in the elderly.

    Science.gov (United States)

    Russo, Teresa; Aprea, Giovanni; Formisano, Cesare; Ruggiero, Simona; Quarto, Gennaro; Serra, Raffaele; Massa, Guido; Sivero, Luigi

    2017-02-01

    The BioEnterics Intragastric Balloon (BIB) and the Spatz Adjustable Balloon System (ABS) are in fact recommended for weight reduction as a bridge to bariatric surgery. We retrospected studied patients with body mass index (BMI) and age ranges of 37-46 and 70-80 years, respectively, who had undergone BIB from January 2010 to July 2012 and prospected studied patients who had undergone Spatz balloon from July 2012 to August 2014. The aim of this study is to compare BIB and Spatz in terms of weight loss, complications, and maintenance of weight after removal. For both procedures, the median weight loss was 20 ± 3 kg, median BMI at the end of the therapy was 32 ± 2, and no severe complication occurred.

  17. Large bowel impaction by the BioEnterics Intragastric Balloon (BIB) necessitating surgical intervention.

    Science.gov (United States)

    Kim, W Y; Kirkpatrick, U J; Moody, A P; Wake, P N

    2000-05-01

    A case of large bowel impaction caused by migration of a BioEnterics Intragastric Balloon (BIB) is presented. The literature is reviewed regarding both the use and the complications inherent in such balloon devices. This is the first reported case of an intragastric balloon impacted in the colon 9 months after insertion.

  18. Hybrid Global Communication Architecture with Balloons and Satellites

    Science.gov (United States)

    Pignolet, G.; Celeste, A.; Erb, B.

    2002-01-01

    Global space communication systems have been developed now for more than three decades, based mainly on geostationary satellites or almost equivalent systems such as the Molnya orbit concepts. The last decade of the twentieth century has seen the emergence of satellite constellations in low or medium Earth orbit, in order to improve accessibility in terms of visibility at higher latitudes and limited size or power requirement for ground equipment. However such systems are complex to operate, there are still many situations where connection may remain difficult to achieve, and commercial benefits are still to be proven. A new concept, using a network combination of geostationary relay satellites and high altitude stratospheric platforms may well overcome the inconveniences of both geostationary systems and satellite constellations to improve greatly global communication in the future. The emergence of enabling technologies developed in Japan and in several other countries will soon make it possible to fly helium balloons in the upper layers of the atmosphere, at altitudes of 20 km or more. At such an altitude, well above the meteorological disturbances and the jet-streams, the stratosphere enjoys a regular wind at moderate speeds ranging between 10 m/s and 30 m/s, depending on latitude and also on season. It is possible for balloons powered by electric engines to fly non- stop upstream of the wind in order to remain stationary above a particular location. Large balloons, with sizes up to 300 m in length, would be able to carry sub-satellite communication payloads, as well as observation apparatus and scientific equipment. The range of visibility for easy both-way communication between the balloon and operators or customers on the ground could be as large as 200 km in radius. Most current studies consider a combination of solar cells and storage batteries to power the balloons, but microwave beam wireless power transportation from the ground could be a very

  19. Biomechanics of occlusion--implications for oral rehabilitation.

    Science.gov (United States)

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated.

  20. Object tracking by occlusion detection via structured sparse learning

    KAUST Repository

    Zhang, Tianzhu

    2013-06-01

    Sparse representation based methods have recently drawn much attention in visual tracking due to good performance against illumination variation and occlusion. They assume the errors caused by image variations can be modeled as pixel-wise sparse. However, in many practical scenarios these errors are not truly pixel-wise sparse but rather sparsely distributed in a structured way. In fact, pixels in error constitute contiguous regions within the object\\'s track. This is the case when significant occlusion occurs. To accommodate for non-sparse occlusion in a given frame, we assume that occlusion detected in previous frames can be propagated to the current one. This propagated information determines which pixels will contribute to the sparse representation of the current track. In other words, pixels that were detected as part of an occlusion in the previous frame will be removed from the target representation process. As such, this paper proposes a novel tracking algorithm that models and detects occlusion through structured sparse learning. We test our tracker on challenging benchmark sequences, such as sports videos, which involve heavy occlusion, drastic illumination changes, and large pose variations. Experimental results show that our tracker consistently outperforms the state-of-the-art. © 2013 IEEE.

  1. Occlusion detection via structured sparse learning for robust object tracking

    KAUST Repository

    Zhang, Tianzhu

    2014-01-01

    Sparse representation based methods have recently drawn much attention in visual tracking due to good performance against illumination variation and occlusion. They assume the errors caused by image variations can be modeled as pixel-wise sparse. However, in many practical scenarios, these errors are not truly pixel-wise sparse but rather sparsely distributed in a structured way. In fact, pixels in error constitute contiguous regions within the object’s track. This is the case when significant occlusion occurs. To accommodate for nonsparse occlusion in a given frame, we assume that occlusion detected in previous frames can be propagated to the current one. This propagated information determines which pixels will contribute to the sparse representation of the current track. In other words, pixels that were detected as part of an occlusion in the previous frame will be removed from the target representation process. As such, this paper proposes a novel tracking algorithm that models and detects occlusion through structured sparse learning. We test our tracker on challenging benchmark sequences, such as sports videos, which involve heavy occlusion, drastic illumination changes, and large pose variations. Extensive experimental results show that our proposed tracker consistently outperforms the state-of-the-art trackers.

  2. Modeling self-occlusions in dynamic shape and appearance tracking

    KAUST Repository

    Yang, Yanchao

    2013-12-01

    We present a method to track the precise shape of a dynamic object in video. Joint dynamic shape and appearance models, in which a template of the object is propagated to match the object shape and radiance in the next frame, are advantageous over methods employing global image statistics in cases of complex object radiance and cluttered background. In cases of complex 3D object motion and relative viewpoint change, self-occlusions and disocclusions of the object are prominent, and current methods employing joint shape and appearance models are unable to accurately adapt to new shape and appearance information, leading to inaccurate shape detection. In this work, we model self-occlusions and dis-occlusions in a joint shape and appearance tracking framework. Experiments on video exhibiting occlusion/dis-occlusion, complex radiance and background show that occlusion/dis-occlusion modeling leads to superior shape accuracy compared to recent methods employing joint shape/appearance models or employing global statistics. © 2013 IEEE.

  3. Central retinal artery occlusion (reversible in sickle trait with glaucoma.

    Science.gov (United States)

    Radius, R L; Finkelstein, D

    1976-01-01

    We report a case of central retinal artery occlusion in an 18-year-old black woman with sickle-trait haemoglobinopathy and acute glaucoma after hyphaema. The central retinal artery occlusion occurred immediately after treatment of the glaucoma with osmotic agents, raising the possibility that they played a precipitating role. We suggest that osmotic agents be used with extreme caution in sickle patients with glaucoma. The occlusion was treated by anterior chamber paracentesis with eventual return of good vision. The reversibility of retinal and optic nerve function after total ischaemia is discussed. PMID:952815

  4. Scientific Ballooning Technologies Workshop STO-2 Thermal Design and Analysis

    Science.gov (United States)

    Ferguson, Doug

    2016-01-01

    The heritage thermal model for the full STO-2 (Stratospheric Terahertz Observatory II), vehicle has been updated to model the CSBF (Columbia Scientific Balloon Facility) SIP-14 (Scientific Instrument Package) in detail. Analysis of this model has been performed for the Antarctica FY2017 launch season. Model temperature predictions are compared to previous results from STO-2 review documents.

  5. Investigating obscure gastrointestinal bleeding : capsule endoscopy or double balloon enteroscopy?

    NARCIS (Netherlands)

    Westerhof, J.; Weersma, R. K.; Koornstra, J. J.

    2009-01-01

    The possibility to visualise the small bowel has dramatically improved with the introduction of capsule endoscopy (CE) and double balloon enteroscopy (DBE). CE and DBE have become standard practice in investigating suspected diseases of the small bowel. An important reason to perform small bowel inv

  6. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  7. 28. Critical pulmonary valve stenosis: Medical management beyond balloon dilation

    Directory of Open Access Journals (Sweden)

    Muhammad Arif Khan

    2015-10-01

    Conclusion: Phentolamine and/or Captopril have a therapeutic role in neonates with critical PVS who remain oxygen dependent after balloon dilation. Both medicationslead to vasodilatation of pulmonary and systemic vascularity. They facilitate inflowto the right ventricle. Right to left shunt across a PFO or/ ASD minimizesand saturation improves leading to a significantreduction in length of hospitalization.

  8. Latex micro-balloon pumping in centrifugal microfluidic platforms.

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Madou, Marc

    2014-03-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.

  9. Balloon atrial septostomy under echocardiographic guide: case series

    Directory of Open Access Journals (Sweden)

    SM Meraji

    2012-12-01

    Full Text Available Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. However, not all centers performing early arterial switch repairs have abandoned atrial septostomy, even in patients who respond favorably to prostaglandin infusion.Case presentation: In total, eight 1- to 15-day old term neonates admitted in Shahid Rajaee Heart Center in Tehran, Iran from October 2009 to February 2011, with congenital heart diseases were scheduled for balloon atrial septostomy. In six cases the procedure was done exclusively under echocardiographic guidance and in two cases with the help of fluoroscopy. Success was defined as the creation of an atrial septal defect with a diameter equal to or more than 5 mm and ample mobility of its margins.Results: Male sex was predominant (87% and the mean age of the neonates was six days. The diagnosis in all cases was simple transposition of great arteries. The procedure was successful in all patients with any cardiovascular complication.Conclusion: Balloon atrial septostomy is an emergent procedure that can be done safely and effectively under echocardiographic guidance. According to the feasibility of this technique it could be performed fast, safe and effective at bedside, avoiding patient transportation to hemodynamic laboratory or referral center.

  10. Using Hydrogen Balloons to Display Metal Ion Spectra

    Science.gov (United States)

    Maynard, James H.

    2008-01-01

    We have optimized a procedure for igniting hydrogen-filled balloons containing metal salts to obtain the brightest possible flash while minimizing the quantity of airborne combustion products. We report air quality measurements in a lecture hall immediately after the demonstration. While we recommend that this demonstration be done outdoors or in…

  11. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  12. 75 FR 77673 - National Environmental Policy Act: Scientific Balloon Program

    Science.gov (United States)

    2010-12-13

    ... SPACE ADMINISTRATION National Environmental Policy Act: Scientific Balloon Program AGENCY: National... the National Environmental Policy Act (NEPA) of 1969, as amended (42 U.S.C. 4321, et seq.); the Council on Environmental Quality Regulations for Implementing the Procedural Provisions of NEPA (40...

  13. Complications of flow-directed balloon-tipped catheters.

    Science.gov (United States)

    Smart, F W; Husserl, F E

    1990-01-01

    Acute or short-term complications following the use of flow-directed balloon-tipped catheters are well recognized. Long-term sequelae are rarely reported. We report herein an early complication of pulmonary arterial rupture with infarction followed by the delayed development of a pulmonary arterial aneurysm.

  14. An automatic parachute release for high altitude scientific balloons

    Science.gov (United States)

    Field, Chris

    NASA's Columbia Scientific Balloon Facility launches high altitude scientific research balloons at many locations around the world. Locations like Antarctica are flat for hundreds of miles and have nothing to snag a parachute consequently causing it to be more important to separate the parachute from the payload than in an area with vegetation and fences. Scientists are now building one of a kind payloads costing millions of dollars, taking five years or more to build, and are requesting multiple flights. In addition to that, the data gathering rate of many science payloads far exceeds the data downlink rate on over-the-horizon flights therefore making a recovery of at least the data hard drives a "minimum success requirement". The older mentality in ballooning; separating the parachute and payload from the balloon and getting it on the ground is more important than separating the parachute after the payload is on the ground has changed. It is now equally as important to separate the parachute from the gondola to prevent damage from dragging. Until now, commands had to be sent to separate the parachute from the gondola at approximately 60K ft, 30K ft, and 10K ft to use the Semi Automatic Parachute Release (SAPR), which is after the sometimes violent parachute opening shock. By using the Gondola controlled Automatic Parachute Release (GAPR) all commanding is done prior to termination, making the parachute release fully autonomous.

  15. [Intestinal occlusion and abdominal compartment syndrome (ACS)].

    Science.gov (United States)

    Stagnitti, Franco

    2009-01-01

    Intestinal occlusion is defined as an independent predictive factor of intra-abdominal hypertension (IAH) which represents an independent predictor of mortality. Baggot in 1951 classified patients operated with intestinal occlusion as being at risk for IAH ("abdominal blow-out"), recommending them for open abdomen surgery proposed by Ogilvie. Abdominal surgery provokes IAH in 44.7% of cases with mortality which, in emergency, triples with respect to elective surgery (21.9% vs 6.8%). In particular, IAH is present in 61.2% of ileus and bowel distension and is responsible for 52% of mortality (54.8% in cases with intra-abdominal infection). These patients present with an increasing intra-abdominal pressure (IAP) which, over 20-25 mmHg, triggers an Abdominal Compartment Syndrome (ACS) with altered functions in some organs arriving at Multiple Organ Dysfunction Syndrome (MODS). The intestine normally covers 58% of abdominal volume but when there is ileus distension, intestinal pneumatosis develops (third space) which can occupy up to 90% of the entire cavity. At this moment, Gastro Intestinal Failure (GIF) can appear, which is a specific independent risk factor of mortality, motor of "Organ Failure". The pathophysiological evolution has many factors in 45% of cases: intestinal pneumatosis is associated with mucosal and serous edema, capillary leakage with an increase in extra-cellular volume and peritoneal fluid collections (fourth space). The successive loss of the mucous barrier permits a bacterial translocation which includes bacteria, toxins, pro-inflammatory factors and oxygen free radicals facilitating the passage from an intra-abdominal to inter-systemic vicious cyrcle. IAH provokes the raising of the diaphragm, and vascular and visceral compressions which induce hypertension in the various spaces with compartmental characteristics. These trigger hypertension in the renal, hepatic, pelvic, thoracic, cardiac, intracranial, orbital and lower extremity areas, giving

  16. The Micro-Instrumentation Package: A Solution to Lightweight Ballooning

    Science.gov (United States)

    Juneau, Jill

    This paper discusses the design and testing of an over the horizon (OTH) light weight telemetry and termination system that can be used for small ballooning payloads. Currently, the Columbia Scientific Balloon Facility (CSBF) provides telemetry for the science payload by integrating one of two types of support packages. The type of support package integrated depends on whether the flight will stay in range of line of sight (LOS) or will exceed LOS requiring the use of over the horizon (OTH) telemetry. The weights of these systems range from 100 pounds to 350 pounds depending upon the use of redundant systems, equipment for high data rates, and batteries and/or solar panels for power requirements. These weight values are not as significant for larger payloads but can be crippling for smaller payloads. In addition, these support package systems are fairly expensive, placing a high importance on recovery. A lightweight and inexpensive telemetry system could be beneficial for various reasons. First, it would allow scientists to fly lightweight payloads on large balloons reaching even higher altitudes. Second, scientists could fly lightweight payloads on less expensive balloons such as meteorological balloons. Depending on the payload, these flights could be fairly inexpensive and even disposable. Third, a compact telemetry system on any balloon will free up more room for the science portion of the payload. In response, a compact telemetry/termination system called the Micro-Instrumentation Package (MIP) was developed. The MIP provides uplink and downlink communications, an interface to the science, housekeeping information including global positioning system (GPS) position, and relays. Instead of a power-hungry microprocessor, the MIP's central consists of a microcontroller. Microcontrollers are lower power, easily programmed, and can be purchased for less than ten dollars. For uplink and downlink telemetry, the MIP uses an LOS serial transceiver and an Iridium unit

  17. High Altitude Infrasound Measurements using Balloon-Borne Arrays

    Science.gov (United States)

    Bowman, D. C.; Johnson, C. S.; Gupta, R. A.; Anderson, J.; Lees, J. M.; Drob, D. P.; Phillips, D.

    2015-12-01

    For the last fifty years, almost all infrasound sensors have been located on the Earth's surface. A few experiments consisting of microphones on poles and tethered aerostats comprise the remainder. Such surface and near-surface arrays likely do not capture the full diversity of acoustic signals in the atmosphere. Here, we describe results from a balloon mounted infrasound array that reached altitudes of up to 38 km (the middle stratosphere). The balloon drifted at the ambient wind speed, resulting in a near total reduction in wind noise. Signals consistent with tropospheric turbulence were detected. A spectral peak in the ocean microbarom range (0.12 - 0.35 Hz) was present on balloon-mounted sensors but not on static infrasound stations near the flight path. A strong 18 Hz signal, possibly related to building ventilation systems, was observed in the stratosphere. A wide variety of other narrow band acoustic signals of uncertain provenance were present throughout the flight, but were absent in simultaneous recordings from nearby ground stations. Similar phenomena were present in spectrograms from the last balloon infrasound campaign in the 1960s. Our results suggest that the infrasonic wave field in the stratosphere is very different from that which is readily detectable on surface stations. This has implications for modeling acoustic energy transfer between the lower and upper atmosphere as well as the detection of novel acoustic signals that never reach the ground. Our work provides valuable constraints on a proposed mission to detect earthquakes on Venus using balloon-borne infrasound sensors.

  18. Bilateral Central Retinal Vein Occlusions Combined with Artery Occlusions in A Patient with Acquired Immune Deficiency Syndrome

    Institute of Scientific and Technical Information of China (English)

    Feng Wen; Xuemei Chen; Haitai Li; Ruiduan Liao; Dezheng Wu

    2002-01-01

    Purpose: This is the first report of a bilateral nonischemic central retinal vein occlusionscombined with artery occlusions in a patient with acquired immune deficiency syndrome(AIDS). Methods: Case report. Results: A 22-year-old Chinese(male) with a positive human immunodeficiency virus(HIV) infection developed bilateral nonischemic central retinal vein occlusions combinedwith artery occlusions and severe vision loss. The manifestations of the fundus andfluorescein angiography were similar in both eyes.Conclusion: This case report provides the evidences that central retinal vein and arteryocclusions are probably part of the spectrum of AIDS vascular diseases.

  19. Fetal MRI in experimental tracheal occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, Ulrike [Department of Diagnostic and Interventional Radiology, Universitaetsklinikum Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)]. E-mail: wedegaer@uke.uni-hamburg.de; Schroeder, Hobe J. [Experimental Gynecology, Department of Obstetrics and Prenatal Medicine, Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany); Adam, Gerhard [Department of Diagnostic and Interventional Radiology, Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany)

    2006-02-15

    Congenital diaphragmatic hernia (CDH) is associated with a high mortality, which is mainly due to pulmonary hypoplasia and secondary pulmonary hypertension. In severely affected fetuses, tracheal occlusion (TO) is performed prenatally to reverse pulmonary hypoplasia, because TO leads to accelerated lung growth. Prenatal imaging is important to identify fetuses with pulmonary hypoplasia, to diagnose high-risk fetuses who would benefit from TO, and to monitor the effect of TO after surgery. In fetal imaging, ultrasound (US) is the method of choice, because it is widely available, less expensive, and less time-consuming to perform than magnetic resonance imaging (MRI). However, there are some limitations for US in the evaluation of CDH fetuses. In those cases, MRI is helpful because of a better tissue contrast between liver and lung, which enables evaluation of liver herniation for the diagnosis of a high-risk fetus. MRI provides the ability to determine absolute lung volumes to detect lung hypoplasia. In fetal sheep with normal and hyperplastic lungs after TO, lung growth was assessed on the basis of cross-sectional US measurements, after initial lung volume determination by MRI. To monitor fetal lung growth after prenatal TO, both MRI and US seem to be useful methods.

  20. Clinical Trials in Branch Retinal Vein Occlusion

    Science.gov (United States)

    Panakanti, Tandava Krishnan; Chhablani, Jay

    2016-01-01

    Branch retinal vein occlusion (BRVO) is the second most common retinal vascular disorder. The management of macular edema has changed considerably over time. The laser is considered the gold standard treatment for over two decades. However, visual recovery with laser is usually slow and incomplete. The advent of intravitreal agents, specifically anti-vascular endothelial growth factors (VEGF) have heralded a new era which promises rapid recovery of vision and quality of vision. Randomized clinical trials have reported optimal results with anti-VEGF agents (ranibizumab, bevacizumab, and aflibercept) compared to laser therapy or steroids. However, nearly 50% of the patients require repeat intravitreal anti-VEGF therapy up to 4 years after initiating therapy to sustain the visual gains. The adverse events (systemic and ocular) of these agents are minimal. Monotherapy with anti-VEGF agents have been found to provide better results than any combination with laser. This review article summarizes evidence from randomized controlled trials evaluating treatment options for the treatment of macular edema secondary to BRVO with a special focus on anti-VEGF therapy. PMID:26957837

  1. Clinical trials in branch retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Tandava Krishnan Panakanti

    2016-01-01

    Full Text Available Branch retinal vein occlusion (BRVO is the second most common retinal vascular disorder. The management of macular edema has changed considerably over time. The laser is considered the gold standard treatment for over two decades. However, visual recovery with laser is usually slow and incomplete. The advent of intravitreal agents, specifically anti-vascular endothelial growth factors (VEGF have heralded a new era which promises rapid recovery of vision and quality of vision. Randomized clinical trials have reported optimal results with anti-VEGF agents (ranibizumab, bevacizumab, and aflibercept compared to laser therapy or steroids. However, nearly 50% of the patients require repeat intravitreal anti-VEGF therapy up to 4 years after initiating therapy to sustain the visual gains. The adverse events (systemic and ocular of these agents are minimal. Monotherapy with anti-VEGF agents have been found to provide better results than any combination with laser. This review article summarizes evidence from randomized controlled trials evaluating treatment options for the treatment of macular edema secondary to BRVO with a special focus on anti-VEGF therapy.

  2. Mesiodistal angulation of the lateral teeth to the functional occlusal plane in normal occlusions

    Directory of Open Access Journals (Sweden)

    Hiroshi Ueda

    2016-01-01

    Full Text Available Introduction: Crowding is a malocclusion with irregularly positioned teeth caused by arch length discrepancy (ALD. Its incidence is high compared with the various malocclusions. In a previous study the crowns of the maxillary lateral teeth had erupted mesially in relation to the functional occlusal plane (FOP in patients with Angle Class I malocclusion and highly erupted canines, which had been uprighted by non-extraction orthodontic treatment, yet these results were based on only two cases evaluated by using plaster models. Therefore, the aim of this study was to assess the mesiodistal angulations of both maxillary and mandibular teeth relative to the FOP in normal occlusion by means of cephalograms and identifying the teeth axial factors contributing to the normal dentitions with the least ALD. Materials and Methods: Thirty Japanese young adult patients (6 males, 24 females with normal occlusion were selected to participate in this study; cephalograms were procured from each and the FOP was used as a reference plane for measuring the changes in the axial angulation along with other indicators of vertical growth. Results: Progressive mesial tipping of the maxillary lateral teeth was observed. First premolars tended to express this more than the second premolars but the tipping values were roughly 90° relative to the FOP on the first molars. Conclusion: The maxillary lateral teeth are more mesially angulated compared to the mandibular ones relative to the FOP. Furthermore, progressive mesial tipping of the maxillary lateral teeth was detected, of which axial angulations were significantly correlated to each other, in spite the mandibular premolars and molars being angulated in a similar fashion.

  3. Amplatzer vascular plug for rapid vessel occlusion in interventional neuroradiology.

    Science.gov (United States)

    Banfield, Jillian C; Shankar, Jai Jai Shiva

    2016-02-01

    The purpose of this paper is to report different uses of endovascular Amplatzer vascular plug (AVP) treatment for rapid vessel occlusion in the field of interventional neuroradiology. We retrospectively reviewed our interventional neuroradiology database from November 2010 to July 2015 and found nine patients who were treated with endovascular AVP. AVP was used for rapid vessel occlusion of common carotid artery (1 patient), internal carotid artery (5 patients), vertebral artery (2 patients), and internal jugular vein (1 patient). A median of three AVPs were used with almost immediate occlusion and no thromboembolic complications. Use of AVP is feasible, safe, rapid, and potentially cost-effective method for rapid occlusion of larger size vessels in the head and neck region for different indications.

  4. Celiac artery stenosis/occlusion treated by interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)], E-mail: osamu-3643ik@do9.enjoy.ne.jp; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)

    2009-08-15

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  5. Aortoiliac occlusive disease presenting as sudden onset paraplegia.

    Science.gov (United States)

    Lai, Chien-Hung; Wang, Cheng-Hsien; Wu, Shih-Yun; Shih, Hong-Mo

    2014-07-01

    Thromboembolism and atherosclerotic stenosis both can cause arterial occlusion. Aortoiliac occlusive disease involving bifurcation of the aortoiliac artery induces symptoms of ischemia such as claudication and pain of buttocks and thighs, decreased bilateral femoral pulses, and impotence. Here, we describe a 58-year-old woman with a past history of atrial fibrillation and lacuna stroke with minimal right side weakness. She presented to our emergency department with sudden onset bilateral pain in the legs and paraplegia. A comprehensive examination revealed paresthesia and decreasing bilateral distal pulses. Computed tomographic imaging showed filling defects over the low abdominal aorta just above the bifurcation of the common iliac artery and bilateral femoral arteries. Acute aortic embolic occlusion was suspected. Her symptoms were resolved after emergent thrombectomy for acute limb ischemia. Physicians need to be aware of aortoiliac embolic occlusive disease which may present as acute paraplegia.

  6. Occlusal accommodation and mouthguards for prevention of orofacial trauma.

    LENUS (Irish Health Repository)

    Geary, Julian Lindsay

    2009-01-01

    The aim of this study was to investigate the effect of two types of occlusal accommodation on the arch separation in centric and eccentric arch positions and to assess the opposing tooth contacts in professionally made, thermoformed sports mouthguards.

  7. Central Retinal Vein Occlusion AssociatedWith Sildenafil (Viagra

    Directory of Open Access Journals (Sweden)

    H C Obiudu

    2010-01-01

    Conclusion - Central retinal vein occlusion is a possible adverse effect of sildenafil use. Physicians should be vigilant while prescribing thismedication and avoid its use in patients with elevated intraocular pressure

  8. Clinical and angiographic comparison of asymptomatic occlusive cerebrovascular disease.

    Science.gov (United States)

    Gorelick, P B; Caplan, L R; Langenberg, P; Hier, D B; Pessin, M; Patel, D; Taber, J

    1988-06-01

    We compared clinical and arteriographic features in 106 patients with symptomatic unilateral carotid territory occlusive disease to determine the frequency and distribution of occlusive arterial lesions in asymptomatic vessels. Among black patients who were predominantly from Chicago, young, and female, there were fewer transient ischemic attacks and myocardial infarcts, less claudication, and more asymptomatic lesions of the supraclinoid internal carotid artery, anterior cerebral artery stem, and the middle cerebral artery stem. Among white patients predominantly from New England, elderly, and male, there was more frequent and severe occlusive asymptomatic disease at extracranial carotid and vertebral artery sites. Knowledge of the distribution of asymptomatic lesions will help guide evaluation and treatment strategies for patients with occlusive cerebrovascular disease.

  9. Avoiding occlusal derangement in facial fractures: An evidence based approach

    Directory of Open Access Journals (Sweden)

    Derick Mendonca

    2013-01-01

    Full Text Available Facial fractures with occlusal derangement describe any fracture which directly or indirectly affects the occlusal relationship. Such fractures include dento-alveolar fractures in the maxilla and mandible, midface fractures - Le fort I, II, III and mandible fractures of the symphysis, parasymphysis, body, angle, and condyle. In some of these fractures, the fracture line runs through the dento-alveolar component whereas in others the fracture line is remote from the occlusal plane nevertheless altering the occlusion. The complications that could ensue from the management of maxillofacial fractures are predominantly iatrogenic, and therefore can be avoided if adequate care is exercised by the operating surgeon. This paper does not emphasize on complications arising from any particular technique in the management of maxillofacial fractures but rather discusses complications in general, irrespective of the technique used.

  10. Image Based Solution to Occlusion Problem for Multiple Robots Navigation

    Directory of Open Access Journals (Sweden)

    Taj Mohammad Khan

    2012-04-01

    Full Text Available In machine vision, occlusions problem is always a challenging issue in image based mapping and navigation tasks. This paper presents a multiple view vision based algorithm for the development of occlusion-free map of the indoor environment. The map is assumed to be utilized by the mobile robots within the workspace. It has wide range of applications, including mobile robot path planning and navigation, access control in restricted areas, and surveillance systems. We used wall mounted fixed camera system. After intensity adjustment and background subtraction of the synchronously captured images, the image registration was performed. We applied our algorithm on the registered images to resolve the occlusion problem. This technique works well even in the existence of total occlusion for a longer period.

  11. Cutting balloon angioplasty vs. conventional balloon angioplasty in patients receiving intracoronary brachytherapy for the treatment of in-stent restenosis.

    Science.gov (United States)

    Fasseas, Panayotis; Orford, James L; Lennon, Ryan; O'Neill, Jessica; Denktas, Ali E; Panetta, Carmelo J; Berger, Peter B; Holmes, David R

    2004-10-01

    The objective of this study was to evaluate the safety and efficacy of cutting balloon angioplasty (CBA) for the treatment of in-stent restenosis prior to intracoronary brachytherapy (ICB). Cutting balloon angioplasty may reduce the incidence of uncontrolled dissection requiring adjunctive stenting and may limit "melon seeding" and geographic miss in patients with in-stent restenosis who are subsequently treated with ICB. We performed a retrospective case-control analysis of 134 consecutive patients with in-stent restenosis who were treated with ICB preceded by either CBA or conventional balloon angioplasty. We identified 44 patients who underwent CBA and ICB, and 90 control patients who underwent conventional percutaneous transluminal coronary angioplasty (PTCA) and ICB for the treatment of in-stent restenosis. Adjunctive coronary stenting was performed in 13 patients (29.5%) in the CBA/ICB group and 41 patients (45.6%; P 0.05). Despite sound theoretical reasons why CBA may be better than conventional balloon angioplasty for treatment of in-stent restenosis with ICB, and despite a reduction in the need for adjunctive coronary stenting, we were unable to identify differences in clinical outcome.

  12. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P.A. van den Heuvel (Paul); J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBalloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as c

  13. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease.

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P. van den Heuvel; J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBACKGROUND. Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical o

  14. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    Directory of Open Access Journals (Sweden)

    Mihir Kothari

    2014-01-01

    Full Text Available Part time occlusion therapy is not reported to cause occlusion (reverse amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  15. Dynamic myocardial perfusion in a porcine balloon-induced ischemia model using a prototype spectral detector CT

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Fares, Anas; Levi, Jacob; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2015-03-01

    Myocardial CT perfusion (CTP) imaging is an application that should greatly benefit from spectral CT through the significant reduction of beam hardening (BH) artifacts using mono-energetic (monoE) image reconstructions. We used a prototype spectral detector CT (SDCT) scanner (Philips Healthcare) and developed advanced processing tools (registration, segmentation, and deconvolution-based flow estimation) for quantitative myocardial CTP in a porcine ischemia model with different degrees of coronary occlusion using a balloon catheter. The occlusion severity was adjusted with fractional flow reserve (FFR) measurements. The SDCT scanner is a single source, dual-layer detector system, which allows simultaneous acquisitions of low and high energy projections, hence enabling accurate projection-based material decomposition and effective reduction of BH-artifacts. In addition, the SDCT scanner eliminates partial scan artifacts with fast (0.27s), full gantry rotation acquisitions. We acquired CTP data under different hemodynamic conditions and reconstructed conventional 120kVp images and projection-based monoenergetic (monoE) images for energies ranging from 55keV-to-120keV. We computed and compared myocardial blood flow (MBF) between different reconstructions. With balloon completely deflated (FFR=1), we compared the mean attenuation in a myocardial region of interest before iodine arrival and at peak iodine enhancement in the left ventricle (LV), and we found that monoE images at 70keV effectively minimized the difference in attenuation, due to BH, to less than 1 HU compared to 14 HU with conventional 120kVp images. Flow maps under baseline condition (FFR=1) were more uniform throughout the myocardial wall at 70keV, whereas with 120kVp data about 12% reduction in blood flow was noticed on BH-hypoattenuated areas compared to other myocardial regions. We compared MBF maps at different keVs under an ischemic condition (FFR ratio (CNRf ) between LAD ischemic and remote healthy

  16. Central retinal vein occlusion concomitant with dengue fever

    OpenAIRE

    Velaitham, Punithamalar; Vijayasingham, Nandini

    2016-01-01

    Background Dengue virus infection is on the rise and there is increasing number of ocular complications that are being reported. Most common ocular complications are macular edema, macular hemorrhages, and foveolitis. There are case reports on branch retinal vessel occlusions. Most of the ocular complications are attributed to the bleeding tendency and transudative process in dengue viral infection. This is a case report of ischemic central retinal vein occlusion (CRVO) concomitant with dengu...

  17. Branch retinal vein occlusion associated with quetiapine fumarate

    Directory of Open Access Journals (Sweden)

    Siang Lim

    2011-08-01

    Full Text Available Abstract Background To report a case of branch retinal vein occlusion in a young adult with bipolar mood disorder treated with quetiapine fumarate. Case Presentation A 29 years old gentleman who was taking quetiapine fumarate for 3 years for bipolar mood disorder, presented with sudden vision loss. He was found to have a superior temporal branch retinal vein occlusion associated with hypercholesterolemia. Conclusion Atypical antipsychotic drugs have metabolic side effects which require regular monitoring and prompt treatment.

  18. Occlusal Caries: Biological Approach for Its Diagnosis and Management

    DEFF Research Database (Denmark)

    Carvalho, JC; Dige, Irene; Machiulskiene, V;

    2016-01-01

    occlusal caries lesions in the permanent dentition may be treated by non-invasive fissure sealing. By extending the criteria for non-invasive treatments, traditional restoration of occlusal surfaces can be postponed or even avoided, and the dental health in children and adolescents can be improved....... Selective removal (incomplete) to soft dentin in deep carious lesions has greater success rates than stepwise excavation. Selective (complete) removal to firm dentin has a lower success rate due to increased pulp exposure....

  19. Relationship among malocclusion, number of occlusal pairs and mastication

    OpenAIRE

    Vanesa Rios-Vera; Alfonso Sánchez-Ayala; Plínio Mendes Senna; Gustavo Watanabe-Kanno; Altair Antoninha Del Bel Cury; Renata Cunha Matheus Rodrigues Garcia

    2010-01-01

    This study evaluated the relationship among malocclusion, number of occlusal pairs, masticatory performance, masticatory time and masticatory ability in completely dentate subjects. Eighty healthy subjects (mean age = 19.40 ± 4.14 years) were grouped according to malocclusion diagnosis (n = 16): Class I, Class Class II-2, Class III and Normocclusion (control). Number of occlusal pairs was determined clinically. Masticatory performance was evaluated by the sieving method, and the time used for...

  20. Multiple extra macular branch retinal vein occlusions in hyperhomocysteinemia

    Directory of Open Access Journals (Sweden)

    Abhijit Diwakar Gore

    2014-01-01

    Full Text Available Hyperhomocysteinemia is a well-known modifiable risk factor for thromboembolism. Retinal vascular occlusion in patients having hyperhomocysteinemia is a known entity, particularly in young patients. However, multiple extra macular branch retinal vein occlusion (BRVO is a rare condition, which can be a presentation of this disease. We present a patient who had multiple extra macular BRVO; on complete systemic workup, he was found to have raised homocysteine levels.

  1. Mineralization of human premolar occlusal fissures: a quantitative histochemical microanalysis

    OpenAIRE

    Campos, Antonio; Rodriguez, I. A.; Sanchez-Quevedo, M.C.; García, J. M.; Nieto-Albano, O.H.; Gómez de Ferraris, M. E.

    2000-01-01

    The mechanisms of cariogenesis in occlusal fissures remain elusive because of limited information about fissure structure and wall mineralization. The purpose of the present study was to determine the correlation between morphological patterns in occlusal fissures in human premolars and quantitative histochemical patterns of mineralization in the walls of these formations. We used scanning electron microscopy and quantitative X-ray microanalysis with the peak-t...

  2. Veno-occlusive disease of the colon - CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Rademaker, J. [Department of Radiology I, Medical School Hannover (Germany)

    1998-10-01

    Venous occlusion is a rare cause of ischemic bowel disease and is usually brought about by thrombosis that may occur as a complication of systemic disorders like systemic lupus erythematosus, Behcet disease or Churg-Strauss syndrome. This report describes a patient with veno-occlusive disease of the colon caused by lymphocytic phlebitis. Typical CT findings included homogeneous bowel wall thickening and vascular engorgement. (orig.) (orig.) With 1 fig., 4 refs.

  3. Sheathotomy in complicated cases of branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Crafoord, S.; Karlsson, N.; Cour, M. la

    2008-01-01

    Purpose: To report the clinical experience and results of using a microsurgical technique to decompress the arteriovenous connection in complicated branch retinal vein occlusion (BRVO) combined with haemorrhage, oedema an ischaemia. Methods: We carried out a retrospective, non-randomized, interve......Purpose: To report the clinical experience and results of using a microsurgical technique to decompress the arteriovenous connection in complicated branch retinal vein occlusion (BRVO) combined with haemorrhage, oedema an ischaemia. Methods: We carried out a retrospective, non...

  4. Full Body Pose Estimation During Occlusion using Multiple Cameras

    DEFF Research Database (Denmark)

    Fihl, Preben; Cosar, Serhan

    Automatic estimation of the human pose enables many interesting applications and has therefore achieved much attention in recent years. One of the most successful approaches for estimating unconstrained poses has been the pictorial structures framework. However, occlusions between interacting...... pose estimates in each view. The proposed method in shown to work under heavy occlusions but does not improve the pose estimates in the non-occluded cases in it's current form....

  5. Influence of occlusal splint thickness on the position of mandible

    Institute of Scientific and Technical Information of China (English)

    CHEN Yong-jin; Nagashima T; Nokubi T

    2005-01-01

    Objective: To investigate the influence of occlusal splint thickness on mandibular movement. Methods: Stabilization occlusal splints of 3, 5 and 7 mm thickness were respectively used during clenching from light contact in intercuspal position and the movement of condyles and incisor point were recorded in 5 healthy subjects. Results:The condyles moved anteriorly and superiorly without wearing occlusal splint. When wearing the occlusal splints the condyles displaced anteriorly and inferiorly. The distance of displacement increased gradually with raising the thickness of splint, though the significant difference was just found in right condyle in superior- inferior movement. The condyles went again on a path of anterior and superior direction when subjects clenched from the displaced position. In right condyle the displacement was significantly greater at 7 mm splint than that at 3 mm splint both in anterior-posterior and inferior-superior direction, while in left condyle only in anterior-posterior direction. Meanwhile, the incisal point movement was larger at 7 mm splint than at 3 mm splint in inferior-superior direction. In tapping movement there were no significant differences in condyle movement between the different thickness of occlusal splint. However, the coefficient of variation in total cycle time was the greatest when wearing the splint of 7 mm. Conclusion: Occlusal splint of 7 mm has greater effect than that of 3 mm on condyle movement, but no obvious difference with occlusal splint of 5 mm. When occlusal splint of 7 mm is inserted, the stability of condyle might be influenced during tapping movement.

  6. Isolated supraclinoid occlusive disease of the internal carotid artery.

    Science.gov (United States)

    Lagrèze, H L; Hartmann, A; Ries, F; Wappenschmidt, J; Hanisch, E

    1987-01-01

    Isolated supraclinoid occlusive disease of the internal carotid artery is a rare cause of cerebral ischemia. The authors of the only review of this subject concluded that it is caused predominantly by factors other than atherosclerosis. We examined 6 patients with isolated supraclinoid occlusive lesions. Five of them had one or more risk factors for atherosclerosis. Thus, the isolated stenosis of that part of the internal carotid artery does not seem to represent a particular pathologic entity.

  7. Cephalometric Approach to the Occlusal Vertical Dimension Reestablishment

    OpenAIRE

    João César Zielak; David Gulin Neto; Leonardo Fernandes da Cunha; Tatiana Miranda Deliberador; Allan Fernando Giovanini

    2014-01-01

    The occlusal vertical dimension (OVD) refers to the length of the face as determined by the amount of separation of the jaws. Its determination is important for the manufacture of restorations. However, defining the correct occlusal vertical dimension for edentulous patients is one of the most important steps for function and esthetics rehabilitation. Cephalometry is a standardized method of assessing dental and facial proportions and their interrelation. Additionally, cephalometric analysis ...

  8. Influence of Occlusal Interference on the Prevalence of Temporomandibular Disorders

    OpenAIRE

    Ćelić, R.; Pandurić, J.; Badel, T.; Kraljević, S.; Dulčić, N.

    2002-01-01

    The significance of occlusal interference in the etiology of temporomandibular disorders has been questioned in numerous recent articles. The aim of this study was to determine the prevalence of the clinical signs and symptoms of temporomandibular disorders in a young male nonpatient population and to investigate a possible association between the signs and symptoms of temporomandibular disorders and occlusal interference. A questionnaire including data from history and clinical functional ...

  9. Digital Artery Occlusion Secondary to Plastic Shopping Bag Trauma

    Science.gov (United States)

    Joy, R; Isaacs, JL; McCarthy, RJ

    2007-01-01

    Upper limb digital arterial occlusion is uncommon. We present the case of a 47-year-old man with an ischaemic right middle finger (dominant hand) due to trauma from carrying a heavy plastic shopping bag. Duplex scanning revealed no proximal source of emboli. An angiogram demonstrated occlusions in the medial and lateral digital arteries of the middle digit at the level of the proximal phalanx. Treatment with heparin and warfarin resulted in complete resolution of symptoms. PMID:18201465

  10. Impact of intra-aortic balloon counterpulsation with different balloon volumes on cardiac performance in humans.

    Science.gov (United States)

    Cohen, Marc; Fasseas, Panayotis; Singh, Varinder P; McBride, Ruth; Orford, James L; Kussmaul, William G

    2002-10-01

    Intra-aortic balloon (IAB) counterpulsation can augment the cardiac output. However, the effect of different IAB volumes on cardiac performance has not been adequately evaluated in humans. Eighty-two patients (52 males [63%]; mean age, 65 +/- 12 years; mean body surface area [BSA], 1.8 +/- 0.2 m(2)) had IAB counterpulsation for cardiogenic shock, refractory angina, and preoperatively for high-risk cardiac surgery. Cardiac hemodynamics were prospectively studied during IAB with inflation volumes of 32 vs. 40 cc. Hemodynamic data collected included aortic pressure, pulmonary artery pressure, systemic and mixed venous oxygen saturations, and cardiac output (by Fick). Transthoracic echocardiography (TTE) was used to obtain both velocity time integrals (VTIs) and the area of the left ventricular outflow tract (LVOT). Left ventricular stroke volume was then calculated as LVOT area x VTI. Cardiac output (CO) determined by the Fick method and VTI did not differ significantly (P = NS) between the two inflation volumes (y = 0.002 + 0.97x). In a subgroup of 33 patients with BSA

  11. Prefrontal Hemodynamic Changes Associated with Subjective Sense of Occlusal Discomfort

    Directory of Open Access Journals (Sweden)

    Yumie Ono

    2015-01-01

    Full Text Available We used functional near-infrared spectroscopy to measure prefrontal brain activity accompanying the physical sensation of oral discomfort that arose when healthy young-adult volunteers performed a grinding motion with mild occlusal elevation (96 μm. We simultaneously evaluated various forms of occlusal discomfort using the visual analogue scale (VAS and hemodynamic responses to identify the specific prefrontal activity that occurs with increased occlusal discomfort. The Oxy-Hb responses of selected channels in the bilateral frontopolar and dorsolateral prefrontal cortices increased in participants who reported increased severity of occlusal discomfort, while they decreased in those who reported no change or decreased occlusal discomfort during grinding. Moreover, the cumulative values of Oxy-Hb response in some of these channels were statistically significant predictive factors for the VAS scores. A generalized linear model analysis of Oxy-Hb signals in a group of participants who reported increased discomfort further indicated significant cerebral activation in the right frontopolar and dorsolateral prefrontal cortices that overlapped with the results of correlation analyses. Our results suggest that the increased hemodynamic responses in the prefrontal area reflect the top-down control of attention and/or self-regulation against the uncomfortable somatosensory input, which could be a possible marker to detect the subjective sense of occlusal discomfort.

  12. Occlusion, Orthodontic treatment, and temporomandibular disorders: a review.

    Science.gov (United States)

    McNamara, J A; Seligman, D A; Okeson, J P

    1995-01-01

    A review of the current literature regarding the interaction of morphologic and functional occlusal factors relative to TMD indicates that there is a relatively low association of occlusal factors in characterizing TMD. Skeletal anterior open bite, overjets greater than 6 to 7 mm, retruded cuspal position/intercuspal position slides greater than 4 mm, unilateral lingual crossbite, and five or more missing posterior teeth are the five occlusal features that have been associated with specific diagnostic groups of TMD conditions. The first three factors often are associated with TMJ arthropathies and may be the result of osseous or ligamentous changes within the temporomandibular articulation. With regard to the relationship of orthodontic treatment to TMD, the current literature indicates that orthodontic treatment performed during adolescence generally does not increase or decrease the odds of developing TMD later in life. There is no elevated risk of TMD associated with any particular type of orthodontic mechanics or with extraction protocols. Although a stable occlusion is a reasonable orthodontic treatment goal, not achieving a specific gnathologically ideal occlusion does not result in TMD signs and symptoms. Thus, according to the existing literature, the relationship of TMD to occlusion and orthodontic treatment is minor. Signs and symptoms of TMD occur in healthy individuals and increase with age, particularly during adolescence; thus, TM disorders that originate during various types of dental treatment may not be related to the treatment but may be a naturally occurring phenomenon.

  13. Occlusion of Internal Carotid Artery in Kimura's Disease

    Directory of Open Access Journals (Sweden)

    Tomonori Tamaki

    2010-01-01

    Full Text Available We describe a unique case of Kimura's disease in which cerebral infarction was caused by occlusion of the right internal carotid artery. A 25-year-old man with Kimura's disease was admitted to our hospital because of left hemiparesis. Computed tomography and magnetic resonance imaging of the head showed infarction in the right frontal and temporal lobes. Cerebral angiography demonstrated right internal carotid artery occlusion affecting the C1 segment, with moyamoya-like collateral vessels arising from the right opthalamic artery. Kimura's disease is a chronic disease characterized by the clinical triad of slowly enlarging subcutaneous masses with lymphoid hyperplasia in the head and neck. It often occurs in young Asian men. In our patient, the pathogenesis of internal carotid artery occlusion was unknown. There have only been a few case reports in which occlusion of the internal carotid artery was associated with autoimmune disease, and no previous cases of internal carotid occlusion associated with Kimura's disease have been reported. We suspected that occlusion of this patient's internal carotid artery may be caused by the autoimmune mechanism that underlies Kimura's disease.

  14. Using High Resolution Balloon Photography to Provide Topographic Data

    Science.gov (United States)

    Russell, K.; Bauer, T.

    2009-12-01

    For site-scale projects, the Bureau of Reclamation has used low altitude balloon photogrammetry to obtain high-resolution photographs and detailed topographic information. These data are collected in a fraction of the time and effort it would take to obtain a similar level of detail using traditional methods. This is accomplished at a significantly reduced cost compared to flying LiDAR or aerial photography, which can be prohibitively expensive for small or medium scale projects. Low altitude balloon photogrammetry is a process where overlapping photographs and ground survey control points are input into a photogrammetry software program (AdamTechnology 3DM Analyst Mine Mapping Suite) to produce orthophotographs and digital terrain model (DTM) elevation points. To acquire the photos a digital camera is attached to an 8-foot diameter helium balloon. The balloon is tethered and flown above the location of interest. The camera is controlled remotely while a live image is transmitted to a receiver on the ground. Ground survey control is established by using GPS equipment to survey ground targets placed within the area to be photographed. There are limitations to the process. Data collection is very weather dependent; too much wind causes the balloon to be unstable. Site conditions also determine the feasibility: power lines, trees, and steep embankments can cause difficulties maneuvering the balloon. Although some of the photographs show the underwater portion of the channel; there is little agreement between GPS points and the processed DTM elevations in the channel. The balloon has been used to survey large woody debris (LWD) structures and channel morphology in the Middle Fork John Day River (central Oregon) and monitoring debris after the removal of Chiloquin Dam (Sprague River, southern Oregon). Seventeen LWD structures were installed on the Middle Fork John Day River near John Day, OR in 2007 and 2008 to provide aquatic habitat. Balloon photos were obtained in

  15. Comparison Between Balloon-Assisted and Stent-Assisted Technique for Treatment of Unruptured Internal Carotid Artery Aneurysms

    Science.gov (United States)

    Park, Keun Young; Kim, Dong Joon

    2016-01-01

    Purpose To compare clinical and angiographic outcomes between balloon-assisted (BAC) and stent-assisted coiling for internal carotid artery unruptured aneurysms (ICA-UA). Materials and Methods A total of 227 ICA-UA in 190 patients were treated with BAC (120 patients, 141 ICA-UA) or SAC (70 patients, 86 ICA-UA. We compared characteristics of patients and ICA-UA, and clinical and angiographic outcomes between groups. Results Aneurysm size and neck diameter were greater for SAC than in BAC, but aneurysm volume and coil packing density were not different between groups. Immediate angiographic occlusion grade was better for BAC than for SAC. Periprocedural thromboembolic events were more frequent during SAC (11.6%) than BAC (2.4%) per aneurysm, but hemorrhagic events were the opposite (2.4% for BAC and none for SAC per aneurysm) (p resulting in a modified Rankin scale score of 4. Thus, overall treatment-related morbi-mortality rates were 1.7% in BAC and 2.9% in SAC. At imaging follow-up (BAC, 135 aneurysms [95.7%] for 28.3 months; SAC, 81 aneurysms [94.1%] for 23.9 months), BAC and SAC showed stable or improved occlusion in 94.1% and 95.0%, minor recurrence in 4.4% and 2.5%, and major recurrence in 1.5% and 2.5%, respectively. Conclusion Both BAC and SAC were safe and effective techniques for ICA-UA. There were no differences in morbi-mortality and recurrence rates between groups. PMID:27621946

  16. Dose reduction assessment in dynamic CT myocardial perfusion imaging in a porcine balloon-induced-ischemia model

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.

  17. The Advanced Scintillator Compton Telescope (ASCOT) balloon project

    Science.gov (United States)

    Bloser, Peter F.; Sharma, Tejaswita; Legere, Jason S.; Bancroft, Christopher M.; McConnell, Mark L.; Ryan, James M.; Wright, Alex M.

    2016-07-01

    We describe a project to develop new medium-energy gamma-ray instrumentation by constructing and flying a balloon-borne Compton telescope using advanced scintillator materials combined with silicon photomultiplier readouts. There is a need in high-energy astronomy for a medium-energy gamma-ray mission covering the energy range from approximately 0.4 - 20 MeV to follow the success of the COMPTEL instrument on CGRO. We believe that directly building on the legacy of COMPTEL, using relatively robust, low-cost, off-the-shelf technologies, is the most promising path for such a mission. Fortunately, high-performance scintillators, such as Lanthanum Bromide (LaBr3), Cerium Bromide (CeBr3), and p-terphenyl, and compact readout devices, such as silicon photomultipliers (SiPMs), are already commercially available and capable of meeting this need. We have conducted two balloon flights of prototype instruments to test these technologies. The first, in 2011, demonstrated that a Compton telescope consisting of an liquid organic scintillator scattering layer and a LaBr3 calorimeter effectively rejects background under balloon-flight conditions, using time-of-flight (ToF) discrimination. The second, in 2014, showed that a telescope using an organic stilbene crystal scattering element and a LaBr3 calorimeter with SiPM readouts can achieve similar ToF performance. We are now constructing a much larger balloon instrument, an Advanced Scintillator Compton Telescope (ASCOT) with SiPM readout, with the goal of imaging the Crab Nebula at MeV energies in a one-day flight. We expect a 4σ detection up to 1 MeV in a single transit. We present calibration results of the first detector modules, and updated simulations of the balloon instrument sensitivity. If successful, this project will demonstrate that the energy, timing, and position resolution of this technology are sufficient to achieve an order of magnitude improvement in sensitivity in the mediumenergy gamma-ray band, were it to be

  18. A Spreadsheet Simulation Tool for Terrestrial and Planetary Balloon Design

    Science.gov (United States)

    Raquea, Steven M.

    1999-01-01

    During the early stages of new balloon design and development, it is necessary to conduct many trade studies. These trade studies are required to determine the design space, and aid significantly in determining overall feasibility. Numerous point designs then need to be generated as details of payloads, materials, mission, and manufacturing are determined. To accomplish these numerous designs, transient models are both unnecessary and time intensive. A steady state model that uses appropriate design inputs to generate system-level descriptive parameters can be very flexible and fast. Just such a steady state model has been developed and has been used during both the MABS 2001 Mars balloon study and the Ultra Long Duration Balloon Project. Using Microsoft Excel's built-in iteration routine, a model was built. Separate sheets were used for performance, structural design, materials, and thermal analysis as well as input and output sheets. As can be seen from figure 1, the model takes basic performance requirements, weight estimates, design parameters, and environmental conditions and generates a system level balloon design. Figure 2 shows a sample output of the model. By changing the inputs and a few of the equations in the model, balloons on earth or other planets can be modeled. There are currently several variations of the model for terrestrial and Mars balloons, as well there are versions of the model that perform crude material design based on strength and weight requirements. To perform trade studies, the Visual Basic language built into Excel was used to create an automated matrix of designs. This trade study module allows a three dimensional trade surface to be generated by using a series of values for any two design variables. Once the fixed and variable inputs are defined, the model automatically steps through the input matrix and fills a spreadsheet with the resulting point designs. The proposed paper will describe the model in detail, including current

  19. Leptospirosis and Peripheral Artery Occlusive Disease

    Science.gov (United States)

    Chiu, Chun-Hsiang; Lin, Cheng-Li; Lee, Feng-You; Wang, Ying-Chuan; Kao, Chia-Hung

    2016-01-01

    Abstract Data on the association between peripheral artery occlusive disease (PAOD) and leptospirosis are limited. We conducted a retrospective cohort study for determining whether leptospirosis is one of the possible risk factors for PAOD. Patients diagnosed with leptospirosis by using 2000 to 2010 data from the Taiwan National Health Insurance Research Database. Patients with leptospirosis without a history of PAOD were selected. For each leptospirosis patient, 4 controls without a history of leptospirosis and PAOD were randomly selected and frequency-matched for sex, age, the year of the index date, and comorbidity diseases. The follow-up period was from the time of the initial diagnosis of leptospirosis to the diagnosis date of PAOD, or December 31, 2011. The Cox proportional hazard regression models were used for analyzing the risk of PAOD. During the follow-up period, the cumulative incidence of PAOD was higher among the patients from the leptospirosis cohort than among the nonleptospirosis cohort (log-rank test, P < 0.001). In total, 29 patients with PAOD from the leptospirosis cohort and 81 from the nonleptospirosis cohort were observed with the incidence rates of 2.1 and 1.3 per 1000 person-years, respectively, yielding a crude hazards ratio (HR) of 1.62 (95% confidence interval [CI] = 1.44–1.81) and adjusted HR (aHR) of 1.75 (95% CI = 1.58–1.95). The risk of PAOD was 1.75-fold higher in the patients with leptospirosis than in the general population. PMID:26986166

  20. Guiding occlusal development with functional appliances.

    Science.gov (United States)

    Nielsen, I L

    1996-10-01

    considerable individual response to treatment, and that the occlusal correction occurred through a combination of skeletal and dentoalveolar changes.

  1. Latin American Consensus on Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    Francisco J. Rodriguez

    2016-01-01

    Full Text Available The introduction of anti-VEGF agents has allowed unprecedented progress in the management and treatment of ophthalmologic conditions characterized by an increased vascular permeability and intraocular neovascularization. One of these conditions is retinal vein occlusion (RVO.  RVO is one of the most common causes of reduced vision due to retinal vascular disease. Without timely treatment, macular edema, macular ischemia, neovascularization and other potential sequelae of RVO can lead to photoreceptor cell death and consequently to irreversible vision loss.   Treatments for this indication that have been recently approved by several regulatory agencies throughout the world include: the VEGF inhibitor ranibizumab (Lucentis, Genentech, the VEGF and placental growth factor inhibitor aflibercept (Eylea, Regeneron Pharmaceuticals and Bayer HealthCare, and a slow release intravitreal implant of dexamethasone (Ozurdex, Allergan. In addition bevacizumab (Avastin, Genentech has been used extensively in an off-label manner.   These new treatments allow us to preserve vision for many RVO patients who could not have expected such favorable results just 5 or 6 years ago. However, not every treatment is effective for every patient, and whether one option is superior to another or a combination of options is superior to monotherapy, have yet to be definitively determined.   A growing body of literature with strong evidence supports the use of these new treatments. However, in several instances the literature is not conclusive to support unified management of RVO. This document is a summary analysis on RVO assembled by a group of specialists summoned by the Pan-American Vitreo-Retinal Society (SPRV to participate in this Latin American consensus.

  2. An analysis of the deployment of a pumpkin balloon at Mars

    Science.gov (United States)

    Rand, J. L.; Phillips, M. L.

    2004-01-01

    The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, where the radius used to determine the stress is determined by the volume of the balloon, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. A suitable superpressure balloon has been designed using this technology which will carry 2 kg in the atmosphere of Mars. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a 10 kg system suspended at the nadir of the balloon. As the system falls toward the surface of the planet, helium gas is transferred into the balloon, forming a partially inflated system very similar to an ascending zero pressure balloon. This analysis incorporates the flow of the planetary gas around the inflating balloon which alters the pressure distribution and shape. As a result, stresses are seen to increase beyond the design values which will require the balloon to be redesigned to accommodate this type of dynamic deployment.

  3. Dental occlusion influences knee muscular performances in asymptomatic females.

    Science.gov (United States)

    Grosdent, Stéphanie; O'Thanh, Roseline; Domken, Olivier; Lamy, Marc; Croisier, Jean-Louis

    2014-02-01

    Some authors claim that occlusal appliances can enhance athletic performance. Therefore, this study investigated the influence of dental occlusion on knee muscle strength performance. Twelve healthy female subjects (mean age, 24.1 ± 3.1 years) without temporomandibular joint dysfunction participated in this study. Isokinetic quadriceps and hamstring strength were assessed in relation to 3 randomized jaw conditions: mouth closed in maximum intercuspidation without splint, mouth closed on a balanced splint which optimized contact over the dental arch, mouth closed on a piece of resin of 1 mm which created an imbalanced occlusion. Tests were performed at 60 and 240°·s in concentric and 30°·s in eccentric exertions. Concentric performances did not show any significant difference between the 3 jaw conditions (p > 0.05). In contrast, in the eccentric trials related to quadriceps performance, significant differences (p ≤ 0.05) were observed between the resin condition and the 2 other modalities (without splint or with a balanced splint). The imbalanced occlusion created by the resin component corresponded to an average decrease of 9% in eccentric peak torque. The eccentric hamstring peak torques also showed a significant difference (p ≤ 0.05) between measurements with splint and with resin (7% decrease when occlusion was imbalanced). In conclusion, among asymptomatic females, artificial imbalanced occlusion induces immediate and significant alteration of knee eccentric muscle performances. Therefore, occlusion examination should be undertaken on a regular and frequent basis for high-level athletes. Moreover, for athletes using mouthguards, muscular performance assessments should be planned with and without the dental protection.

  4. Apical ballooning-like syndrome: Hypocalcemia? What else!

    Directory of Open Access Journals (Sweden)

    Maria Accadia

    2016-01-01

    Full Text Available Apical ballooning syndrome (ABS, also known as Takotsubo or stress cardiomyopathy, is characterised by acute, transient and severe LV dysfunction, mimicking myocardial infarction; it occurs, in most cases, in the absence of obstructive coronary disease and is precipitated by severe emotional or physical stress, but many other potential triggers has been identi ed in the last years. Although the pathogenesis of ABS remains unclear, the most common mechanisms suggested are coronary vasospam and an exaggerated sympathetic activation associated to high levels of plasma cathecolamine leading to cardiotoxicity.We describe two cases of Apical Ballooning like Syndrome that were triggered by severe, acute hypocalcemia, without evidence of coronary vasospasm and with normal hematic level of cathecolamines.

  5. Developing International Standards for Meteorological Balloon to Facilitate Industrial Progress

    Institute of Scientific and Technical Information of China (English)

    Deng Yizhi

    2011-01-01

    Meteorological balloon is made of natural rubber latex with a special process.On natural conditions,it carries the air sounding instrument into the high air to detect the meteorological elements in the air.As a means of delivery used in the aerological sounding,it is widely used in the meteorological,sailing,aeronautical,aerospace and other fields,and plays an extremely important role in the weather report,disaster prevention,disaster relief,guaranteeing ships and aircrafts to leave ports safely,and scientific research in relevant spaces,etc.Especially,the role of meteorological balloons is not ignorable in the forecast of extremely adverse weather frequently occurring around the world in recent years.

  6. MIPAS Ozone Validation by Stratospheric Balloon and Aircraft Measurements

    Science.gov (United States)

    Cortesi, U.; Blom, C. E.; Camy-Peyret, C.; Chance, K.; Davies, J.; Goutail, F.; Kuttippurath, J.; McElroy, C. T.; Mencaraglia, F.; Oelhaf, H.; Petritoli, A.; Pirre, M.; Pommereau, J. P.; Ravegnani, F.; Renard, J. B.; Strong, K.

    2004-08-01

    A number of in situ and remote sensing techniques for the measurement of upper tropospheric and stratospheric O3 content was employed during dedicated experiments of the ESABC programme, aiming at the validation of the ENVISAT chemistry payload. In this paper, we will be focusing on the validation of MIPAS off-line products, by presenting the results of the intercomparison between MIPAS O3 vertical profiles and aircraft and balloon correlative measurements. First priority is given to the validation of processor v4.61 data, but individual results of 2002 and 2003 balloon observations are also compared with MIPAS O3 non operational data. Some general remarks are finally expressed, along with specific recommendation to fully exploit the available ESABC validation dataset

  7. Apical ballooning-like syndrome: Hypocalcemia? What else!

    OpenAIRE

    Maria Accadia; Marianna Abitabile; Salvatore Rumolo; Scotto di Uccio Fortunato; Luigi Irace; Andrea Tuccillo; Giuseppe Mercogliano; Bernardino Tuccillo

    2016-01-01

    Apical ballooning syndrome (ABS), also known as Takotsubo or stress cardiomyopathy, is characterised by acute, transient and severe LV dysfunction, mimicking myocardial infarction; it occurs, in most cases, in the absence of obstructive coronary disease and is precipitated by severe emotional or physical stress, but many other potential triggers has been identi ed in the last years. Although the pathogenesis of ABS remains unclear, the most common mechanisms suggested are coronary vasospam an...

  8. The Extreme Universe Space Observatory Super Pressure Balloon Mission

    Science.gov (United States)

    Wiencke, Lawrence; Olinto, Angela; Adams, Jim; JEM-EUSO Collaboration

    2017-01-01

    The Extreme Universe Space Observatory on a super pressure balloon (EUSO-SPB) mission will make the first fluorescence observations of high energy cosmic ray extensive air showers by looking down on the atmosphere from near space. A long duration flight of at least 50 nights launched from Wanaka NZ is planned for 2017. We describe completed instrument, and the planned mission. We acknowledge the support of NASA through grants NNX13AH53G and NNX13AH55G.

  9. Astronomical observations with the University College London balloon borne telescope

    Science.gov (United States)

    Jennings, R. E.

    1974-01-01

    The characteristics of a telescope system which was developed for high altitude balloon astronomy are discussed. A drawing of the optical system of the telescope is provided. A sample of the signals recorded during one of the flights is included. The correlation between the infrared flux and the radio continuum flux is analyzed. A far infrared map of the radio and infrared peaks of selected stars is developed. The spectrum of the planet Saturn is plotted to show intensity as compared with wavenumber.

  10. Double-balloon enteroscopy in detecting small intestinal bleeding

    Institute of Scientific and Technical Information of China (English)

    ZHI Fa-chao; PAN De-shou; ZHOU Dian-yuan; XIAO Bing; JIANG Bo; WAN Tian-mo; GUO Yu; ZHOU Dan; WANG Li-hui; CHEN Jin-feng; XIE Lu

    2005-01-01

    @@ Digestive tract hemorrhage is a common disease of the digestive system, but about 0.4%-5% intestinal bleeding can not be detected with gastroscope or colonscope.1 Since the intestine is long, tortuous, far away from both ends of the digestive tract and unfixed in position, clinical diagnosis of the bleeding is relatively difficult. Yamamoto and Sugano2 reported the clinical application of double-balloon enteroscope at American DDW in 2003.

  11. Balloon Kyphoplasty: An Effective Treatment for Kummell Disease?

    Science.gov (United States)

    Kim, Pius

    2016-01-01

    Objective The purpose of this study was to evaluate the efficacy of balloon kyphoplasty for treating Kummel disease accompanying severe osteoporosis. Methods Twelve patients with single-level Kummell disease accompanied by severe osteoporosis were enrolled in this investigation. After postural reduction for 1 or 2 days, balloon kyphoplasty was performed on the collapsed vertebrae. Clinical results, radiological parameters, and related complications were assessed at 7 days, 1 month and 6 months after the procedure. Results Prior to kyphoplasty, the mean pain score (according to the visual analogue scale) was 8.0. Seven days after the procedure, this score improved to 2.5. Despite the significant improvement compared to preoperative value, the score increased to 4.0 at 6 months after the procedure. The mean preoperative vertebral height loss was 55.4%. Kyphoplasty reduced this loss to 31.6%, but it increased to 38.7% at 6 months after the procedure. The kyphotic angle improved significantly from 22.4°±4.9° (before the procedure) to 10.1°±3.8° after surgery, However, the improved angle was not maintained 6 months after the procedure. The mean correction loss for the kyphotic deformity was 7.2° at 6 months after the procedure. Three out of 12 patients sustained adjacent fractures after balloon kyphoplasty within 6 months. Conclusion Although balloon kyphoplasty for treating Kummell disease is known to provide stabilization and pain relief, it may be associated with the development of adjacent fractures and aggravated kyphosis. PMID:27799987

  12. Prime time for drug eluting balloons in SFA interventions?

    Science.gov (United States)

    Brodmann, M

    2014-08-01

    Peripheral arterial disease most commonly affects the femoropopliteal segment. Despite enormous improvements in device and treatment technology the long-term patency rate and clinical benefit of endovascular treatment in the respective vascular bed is not satisfying. Drug coated balloon technology as a treatment option in femoropopliteal disease has shown encouraging results in first-in-man trials, which have now been proven in large randomized controlled trials.

  13. NEW APPROACHES: A hot air balloon from dustbin liners

    Science.gov (United States)

    Weaver, Nicholas

    1998-07-01

    This article describes how a simple hot air balloon, inflated by a hair dryer, can be made out of household bin liners and Sellotape. It can be used at sixth-form level as an application of the ideal gas equation, = constant, and is rather more exciting than heated pistons. It gives a taste of a simple engineering design process, although the students do have to be reasonably adept at geometry and algebra.

  14. A Sensitivity Analysis of fMRI Balloon Model

    KAUST Repository

    Zayane, Chadia

    2015-04-22

    Functional magnetic resonance imaging (fMRI) allows the mapping of the brain activation through measurements of the Blood Oxygenation Level Dependent (BOLD) contrast. The characterization of the pathway from the input stimulus to the output BOLD signal requires the selection of an adequate hemodynamic model and the satisfaction of some specific conditions while conducting the experiment and calibrating the model. This paper, focuses on the identifiability of the Balloon hemodynamic model. By identifiability, we mean the ability to estimate accurately the model parameters given the input and the output measurement. Previous studies of the Balloon model have somehow added knowledge either by choosing prior distributions for the parameters, freezing some of them, or looking for the solution as a projection on a natural basis of some vector space. In these studies, the identification was generally assessed using event-related paradigms. This paper justifies the reasons behind the need of adding knowledge, choosing certain paradigms, and completing the few existing identifiability studies through a global sensitivity analysis of the Balloon model in the case of blocked design experiment.

  15. The Rocket Balloon (Rocketball): Applications to Science, Technology, and Education

    Science.gov (United States)

    Esper, Jaime

    2009-01-01

    Originally envisioned to study upper atmospheric phenomena, the Rocket Balloon system (or Rocketball for short) has utility in a range of applications, including sprite detection and in-situ measurements, near-space measurements and calibration correlation with orbital assets, hurricane observation and characterization, technology testing and validation, ground observation, and education. A salient feature includes the need to reach space and near-space within a critical time-frame and in adverse local meteorological conditions. It can also provide for the execution of technology validation and operational demonstrations at a fraction of the cost of a space flight. In particular, planetary entry probe proof-of-concepts can be examined. A typical Rocketball operational scenario consists of a sounding rocket launch and subsequent deployment of a balloon above a desired location. An obvious advantage of this combination is the additional mission 'hang-time' rendered by the balloon once the sounding rocket flight is completed. The system leverages current and emergent technologies at the NASA Goddard Space Flight Center and other organizations.

  16. Balloon Cell Urethral Melanoma: Differential Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    M. McComiskey

    2015-01-01

    Full Text Available Introduction. Primary malignant melanoma of the urethra is a rare tumour (0.2% of all melanomas that most commonly affects the meatus and distal urethra and is three times more common in women than men. Case. A 76-year-old lady presented with vaginal pain and discharge. On examination, a 4 cm mass was noted in the vagina and biopsy confirmed melanoma of a balloon type. Preoperative CT showed no distant metastases and an MRI scan of the pelvis demonstrated no associated lymphadenopathy. She underwent anterior exenterative surgery and vaginectomy also. Histology confirmed a urethral nodular malignant melanoma. Discussion. First-line treatment of melanoma is often surgical. Adjuvant treatment including chemotherapy, radiotherapy, or immunotherapy has also been reported. Even with aggressive management, malignant melanoma of the urogenital tract generally has a poor prognosis. Recurrence rates are high and the mean period between diagnosis and recurrence is 12.5 months. A 5-year survival rate of less than 20% has been reported in balloon cell melanomas along with nearly 20% developing local recurrence. Conclusion. To the best of our knowledge, this case is the first report of balloon cell melanoma arising in the urethra. The presentation and surgical management has been described and a literature review provided.

  17. The balloon-borne electron telescope with scintillating fibers (BETS)

    CERN Document Server

    Torii, S; Tateyama, N; Yoshida, K; Ouchi, Y; Yamagami, T; Saitô, Y; Murakami, H; Kobayashi, T; Komori, Y; Kasahara, K; Yuda, T; Nishimura, J

    2000-01-01

    we describe a new detector system developed for high-altitude balloon flights to observe the cosmic-ray electrons above 10 GeV. The balloon borne electron telescope with Scintillating (BETS) fibers instrument is an imaging calorimeter which is capable of selecting electrons against the large background of protons. The calorimeter is composed of a sandwich of scintillating optical-fiber belts and lead plates with a combination of three plastic scintillators for the shower trigger. The total thickness of lead is 40 mm (~7.1 r.l.) and the number of fiber belts is nine. In each belt, alternating layers are oriented in orthogonal (x and y) directions. Two sets of an intensified CCD camera are adopted for read-out of the scintillating fibers in the x and y direction, respectively. The accelerator beam tests were carried out to study the performance of detector for electrons in 1996 and for protons in 1997 at CERN-SPS. The instrument was successfully flown aboard high-altitude balloon in 1997 and 1998. It is demonst...

  18. Precision Attitude Control for the BETTII Balloon-Borne Interferometer

    Science.gov (United States)

    Benford, Dominic J.; Fixsen, Dale J.; Rinehart. Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. Operating at wavelengths of 30-90 microns, BETTII will obtain spatial and spectral information on science targets at angular resolutions down to less than half an arcsecond, a capability unmatched by other far-infrared facilities. This requires attitude control at a level ofless than a tenth of an arcsecond, a great challenge for a lightweight balloon-borne system. We have designed a precision attitude determination system to provide gondola attitude knowledge at a level of 2 milliarcseconds at rates up to 100Hz, with accurate absolute attitude determination at the half arcsecond level at rates of up to 10Hz. A mUlti-stage control system involving rigid body motion and tip-tilt-piston correction provides precision pointing stability to the level required for the far-infrared instrument to perform its spatial/spectral interferometry in an open-loop control. We present key aspects of the design of the attitude determination and control and its development status.

  19. Low Cost Balloon programme of Indian Centre for Space Physics

    Science.gov (United States)

    Chakrabarti, Sandip Kumar

    2016-07-01

    Indian Centre for Space Physics has launched 89 Missions to near space using single or multiple weather balloons or very light plastic balloons. Basic goal was to capitalize miniaturization of equipments in modern ages. Our typical payload of less than 4kg weight consists of GPS, video camera, cosmic ray detectors, Attitude measurement unit, sunsensor and most importantly a 50-100sqcm X-ray/Gamma-ray detector (usually a scintillator type). The main purpose of the latter is to study spectra of secondary cosmic ray spectra (till our ceiling altitude of 36-42km) over the years and their seasonal variation or variation with solar cycle. We also study solar X-ray spectra, especially of solar flares. We have detected a Gamma Ray Burst (GRB) and pulsars. Our observation of black hole candidates did not yield satisfactory result yet mainly because of poor collimation (~ 10 deg x 10 deg) by lead collimator which introduces strong background also. Our effort with multiple balloon flights enabled us to have long duration flights. We believe that our procedure is very futuristic and yet at an affordable cost.

  20. A Low Cost Weather Balloon Borne Solar Cell Calibration Payload

    Science.gov (United States)

    Snyder, David B.; Wolford, David S.

    2012-01-01

    Calibration of standard sets of solar cell sub-cells is an important step to laboratory verification of on-orbit performance of new solar cell technologies. This paper, looks at the potential capabilities of a lightweight weather balloon payload for solar cell calibration. A 1500 gr latex weather balloon can lift a 2.7 kg payload to over 100,000 ft altitude, above 99% of the atmosphere. Data taken between atmospheric pressures of about 30 to 15 mbar may be extrapolated via the Langley Plot method to 0 mbar, i.e. AMO. This extrapolation, in principle, can have better than 0.1 % error. The launch costs of such a payload arc significantly less than the much larger, higher altitude balloons, or the manned flight facility. The low cost enables a risk tolerant approach to payload development. Demonstration of 1% standard deviation flight-to-flight variation is the goal of this project. This paper describes the initial concept of solar cell calibration payload, and reports initial test flight results. .

  1. Occlusal Grinding Pattern during Sleep Bruxism and Temporomandibular Disorder

    Directory of Open Access Journals (Sweden)

    Yeni Wijaya

    2013-09-01

    Full Text Available Sleep Bruxism is a significant etiology of temporomandibular disorder (TMD and causes many dental or oral problems such as tooth wear or facet. There is no study analyzing the relationship between sleep bruxism and TMD. Objective: To investigate any relationship between occlusal grinding pattern during sleep bruxism and temporomandibular disorder. Methods: A cross-sectional study involving 30 sleep bruxism patients attended the Faculty Dentistry Universitas Indonesia Teaching Hospital (RSGMP FKG UI. Completion of 2 forms of ID-TMD index and questionnaire from American Academy of Sleep Medicine were done. BruxChecker was fabricated and used for two nights to record the occlusal grinding pattern. The occlusal grinding pattern was categorized into laterotrusive grinding (LG and mediotrusive side. Further divisons of LG were: incisor-canine (IC, incisor-caninepremolar (ICP and incisor-canine-premolar-molar (ICPM. Mediotrusive side was classified as mediotrusive contact (MC and mediotrusive grinding (MG. Results: It was found that occlusal grinding pattern in non-TMD subjects were IC+MC, in subjects with mild TMD were ICP+MG and in subjects with moderate TMD were ICP+MG and ICPM+MG. TMJ was more significantly affected by ICP and ICPM grinding pattern than that of IC. Conclusion: There was a significant relationship between occlusal grinding pattern during sleep bruxism and TMD.DOI: 10.14693/jdi.v20i2.149

  2. Mechanism of vaso-occlusion in sickle cell anemia

    Science.gov (United States)

    Lei, Huan; Karniadakis, George

    2012-11-01

    Vaso-occlusion crisis is one of the key hallmark of sickle cell anemia. While early studies suggested that the crisis is caused by blockage of a single elongated cell, recent experimental investigations indicate that vaso-occlusion is a complex process triggered by adhesive interactions among different cell groups in multiple stages. Based on dissipative particle dynamics, a multi-scale model for the sickle red blood cells (SS-RBCs), accounting for diversity in both shapes and cell rigidities, is developed to investigate the mechanism of vaso-occlusion crisis. Using this model, the adhesive dynamics of single SS-RBC was investigated in arterioles. Simulation results indicate that the different cell groups (deformable SS2 RBCs, rigid SS4 RBCs, leukocytes, etc.) exhibit heterogeneous adhesive behavior due to the different cell morphologies and membrane rigidities. We further simulate the tube flow of SS-RBC suspensions with different cell fractions. The more adhesive SS2 cells interact with the vascular endothelium and further trap rigid SS4 cells, resulting in vaso-occlusion in vessels less than 15 μm . Under inflammation, adherent leukocytes may also trap SS4 cells, resulting in vaso-occlusion in even larger vessels. This work was supported by the NSF grant CBET-0852948 and the NIH grant R01HL094270.

  3. Diagnosis of occlusal caries: Part I. Conventional methods.

    Science.gov (United States)

    McComb, D; Tam, L E

    2001-09-01

    Accurate diagnosis of the presence or absence of disease is a fundamental requirement in health care. The diagnosis of non-overt occlusal decay is challenging and can be highly subjective, and its inherent uncertainties can lead to widely differing treatment decisions. The development of more sensitive, specific and reproducible diagnostic tools for occlusal surfaces would contribute greatly to more precise planning of preventive and operative therapy. The purpose of this 2-part paper is to review current knowledge concerning conventional and new diagnostic methods for occlusal caries. Part I looks at established diagnostic methods for occlusal surfaces. Conventional visual, tactile and radiographic examinations provide less-than-ideal diagnostic sensitivity. Neither fissure discolouration (black or brown) nor the use of an explorer has been shown to improve diagnostic accuracy. However, the combination of careful visual examination with optimal radiographic examination affords better diagnostic performance. The best visual indicators involve precise features associated with the presence of disease, such as opaque fissure demineralization and the presence and extent of localized breakdown of the enamel. For best results, teeth should be clean, thoroughly dry and well illuminated. Part II will examine new and emerging technologies, including the DIAGNOdent laser fluorescence device, which are being developed for the diagnosis of occlusal decay.

  4. Radiological evaluation of multiple progressive intracranial arterial occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Whan; Choi, Byung Ihn; Ha, Sung Whan [Capital Armed Forces General Hospital, Seoul (Korea, Republic of)

    1980-12-15

    Multiple Progressive intracranial Arterial Occlusion (MPIAO) is a rare cerebrovascular disease and its clinical diagnosis is nearly impossible and diagnosis depends upon neuroradiological studies. Among neuroradiological studies, cerebral angiography is mandatory in diagnosis and in localization of stenotic or occlusive vascular lesion, visualization of collateral channels and aid the surgical management. Five cases MPIAO which were proved by cerebral angiography at Capital Armed Forces General Hospital during last 5 years are presented, with analysis of radiological findings as well as clinical assessment. The results are as follows; 1. Age distribution ranges from 23 to 46. For cases are male and one female. 2. Cardinal clinical symptoms are headache and vomiting, and neurological manifestations are hemiplegia and speech disturbance. 3. All cases show the characteristic angiographic findings of MPIAO which are occlusion or stenosis at the distal internal carotid artery, proximal part of anterior and middle cerebral arteries with fine collateral network in basal ganglia area, leptomeningeal anastomosis and transdural external-internal carotid anastomoses. The major region of occlusion or stenosis is first portion of anterior and middle cerebral arteries. In one case, the lesion is seen in cervical portion of internal carotid artery. There is no evidence of occlusion or stenosis in vertebral angiogram. 4. In 2 cases, computed tomography was done. One case shows the findings of cerebral infarction and the other intracerebral hematoma.

  5. Systemic abnormalities associated with retinal vein occlusion in young patients

    Science.gov (United States)

    Sinawat, Suthasinee; Bunyavee, Chavisa; Ratanapakorn, Tanapat; Sinawat, Supat; Laovirojjanakul, Wipada; Yospaiboon, Yosanan

    2017-01-01

    Objectives To study the systemic abnormalities associated with retinal vein occlusion in patients aged ≤50 years with a particular emphasis on atherosclerotic diseases and thrombophilic disorders. Methods Medical charts of patients, aged ≤50 years whose diagnoses were retinal vein occlusions during the period 1995–2015 were retrospectively reviewed. The primary outcome was the number of systemic abnormalities associated with these patients. Secondary outcomes included types of retinal vein occlusion and sites of occlusion. Results Atherosclerotic diseases were the most common systemic abnormalities associated with retinal vein occlusion and accounted for 55.1% of the patients in the study. Hypertension in 27.55%, diabetes mellitus in 16.33%, and 5.1% with dyslipidemia were noted. The number of thrombophilic disorders seemed to be less than expected and were noted in only 5.1%. Other systemic abnormalities included viral hepatitis infection, systemic lupus erythematosus, and acquired immunodeficiency syndrome. Oral contraceptives were used by some patients. Conclusion Atherosclerotic diseases remained the most commonly associated systemic diseases in the majority of these patients. Approach to these patients should include a screening for hypertension, diabetes mellitus, and lipid abnormalities. Thrombophilia should also be considered where no obvious atherosclerotic diseases are found or if the patient is <40 years old, a history of thrombosis or a family history of thrombosis is possible. PMID:28260858

  6. Transcatheter pulmonary valve perforation using chronic total occlusion wire in pulmonary atresia with intact ventricular septum

    Science.gov (United States)

    Bakhru, Shweta; Marathe, Shilpa; Saxena, Manish; Verma, Sudeep; Saileela, Rajan; Dash, Tapan K; Koneti, Nageswara Rao

    2017-01-01

    Background: Perforation of pulmonary valve using radiofrequency ablation in pulmonary atresia with intact ventricular septum (PA IVS) is a treatment of choice. However, significant cost of the equipment limits its utility, especially in the developing economies. Objective: To assess the feasibility, safety, and efficacy of perforation of pulmonary valve using chronic total occlusion (CTO) wires in patients with PA IVS as an alternative to radiofrequency ablation. Methods: This is a single-center, nonrandomized, retrospective study conducted during June 2008 to September 2015. Twenty-four patients with PA IVS were selected for the procedure during the study period. The median age and weight of the study population were 8. days and 2.65 kg, respectively. Four patients were excluded after right ventricular angiogram as they showed right ventricular-dependent coronary circulation. The pulmonary valve perforation was attempted using various types of CTO wires based on the tip load with variable penetrating characteristics. Results: The procedure was successful in 16 of twenty patients using CTO wires: Shinobi in nine, Miracle in four, CROSS-IT in two, and Conquest Pro in one. Two patients had perforation of right ventricular outflow tract (RVOT). Pericardiocentesis was required in one patient to relieve cardiac tamponade. Later, the same patient underwent successful hybrid pulmonary valvotomy. The other patient underwent ductus arteriosus (DA) stenting. Balloon atrial septostomy was needed in three cases with systemic venous congestion. Desaturation was persistent in five cases necessitating DA or RVOT stenting to augment pulmonary blood flow. There were two early and two late deaths. The mean follow-up was 22.66 ± 16 months. Three patients underwent one and half ventricle repair and one Blalock–Taussig shunt during follow-up. Conclusion: Perforation of the pulmonary valve can be done successfully using CTO wires in selected cases of pulmonary atresia with intact

  7. The Liege-balloon program. [balloon-borne instruments for high-spectral resolution observations of the sun

    Science.gov (United States)

    Zander, R.

    1974-01-01

    The Liege-balloon program is intended to make high-spectral resolution observations of the sun in the near- and intermediate infrared regions not accessible from the ground. A description of the equipment, followed by a summary of the data obtained till now is presented. Except for ozone whose maximum of concentration lies near 25 Km altitude, the residual mass distribution of the other mentioned molecules decreases with altitude. This is a self-explanatory argument for carrying out spectroscopic observations from platforms transcending the densest layers of the earth's atmosphere. The Liege balloon equipment is primarily intended for very high-resolution solar observations from about 27-30 Km altitude, in all spectral regions between 1.5 and 15.0 microns, not accessible from the ground.

  8. Double Balloon Cervical Ripening Catheter for Control of Massive Hemorrhage in a Cervical Ectopic Pregnancy

    Science.gov (United States)

    Zambrano, Nabila; Reilly, James; Moretti, Michael

    2017-01-01

    Cervical pregnancy can be complicated by perfuse vaginal bleeding. Mechanical compression directed at tamponing the cervical vessels can control hemostasis. There are several types of balloon catheters that have been described for cervical compression. However use of a double balloon catheter is a novel approach for cervical tamponade, as one balloon is positioned below the external cervical os and the second balloon is situated above in the internal cervical os. This compresses the cervix from internal os to external os between the two balloons, forming a “cervical sandwich.” We describe this method of cervical tamponade using a silicone double balloon cervical ripening catheter that rapidly controlled hemorrhage in a patient that failed conservative management with methotrexate. PMID:28261511

  9. Experimental investigation of undesired stable equilibria in pumpkin shape super-pressure balloon designs

    Science.gov (United States)

    Schur, W. W.

    2004-01-01

    Excess in skin material of a pneumatic envelope beyond what is required for minimum enclosure of a gas bubble is a necessary but by no means sufficient condition for the existence of multiple equilibrium configurations for that pneumatic envelope. The very design of structurally efficient super-pressure balloons of the pumpkin shape type requires such excess. Undesired stable equilibria in pumpkin shape balloons have been observed on experimental pumpkin shape balloons. These configurations contain regions with stress levels far higher than those predicted for the cyclically symmetric design configuration under maximum pressurization. Successful designs of pumpkin shape super-pressure balloons do not allow such undesired stable equilibria under full pressurization. This work documents efforts made so far and describes efforts still underway by the National Aeronautics and Space Administration's Balloon Program Office to arrive on guidance on the design of pumpkin shape super-pressure balloons that guarantee full and proper deployment.

  10. Vessel wall temperature estimation for novel short term thermal balloon angioplasty: study of thermal environment.

    Science.gov (United States)

    Kaneko, Kenji; Nakatani, Eriko; Futami, Hikaru; Ogawa, Yoshifumi; Arai, Tsunenori; Fukui, Masaru; Shimamura, Satoshi; Kawabata, Takashi

    2005-01-01

    We have been proposing novel thermal balloon angioplasty, photo-thermo dynamic balloon angioplasty (PT-DBA). PTDBA realized thermal injury and low pressure dilatation that can prevent restenosis in chronic phase. We aim to determine the most efficient heating condition suit to individual symptom with pre-operation thermal simulation. We analyzed the flow dynamics and heat convection inside the balloon, and investigated heat conduction of balloon film to establish the temperature estimation method among vessel wall. Compared with ex vivo temperature measurement experiment, we concluded that the factors need to be considered for the establishment would be the heat conduction of the flow inside PTDB, heat conduction at the balloon film, and contact thermal resistance between the balloon film and vessel wall.

  11. Transaortic Intra-Aortic Balloon Pump Catheter Insertion through a Separate Saphenous Vein Graft in Patients with Severe Aortoiliac Disease

    Directory of Open Access Journals (Sweden)

    Faruk Toktas

    2014-01-01

    Full Text Available Background. Intra-aortic balloon pump (IABP is the most widely used mechanical assist device for hemodynamic support in high risk patients undergoing cardiac surgery. The aim of our study was to confirm whether transaortic route is a suitable alternative to allow IABP insertion in patients with severe aortoiliac diseases. Methods. This study included 7 consecutive patients undergoing coronary artery bypass grafting for severe coronary artery disease associated with severe aortoiliac disease. These patients could not be weaned from cardiopulmonary bypass and required the IABP support, which were placed through the ascending aorta. IABP catheter was inserted indirectly through a separate saphenous vein graft anastomosed to the ascending aorta by an end-to-side manner under a partial occluding clamp and advanced to the desired position in the descending thoracic aorta and exteriorly brought into the subcutaneous tissues in the jugulum. Results. The procedure was successfully performed in all the patients. The mean duration of IABP support was 54.0±13.4 hours. There were no in-hospital mortality and complications related to transaortic route. IABP removal did not require repeat sternotomy. At postoperative 6th month, multislice CT examination showed thrombotic occlusion at the remnant of the saphenous vein graft. Conclusions. This technique is a simple, reliable, and reproducible option in patients with severe aortoiliac disease in whom retrograde femoral route is not possible.

  12. Thrombocytopenia in Patients with Gastric Varices and the Effect of Balloon-occluded Retrograde Transvenous Obliteration on the Platelet Count

    Directory of Open Access Journals (Sweden)

    W E Saad

    2014-01-01

    Full Text Available Objectives: Gastric varices primarily occur in cirrhotic patients with portal hypertension and splenomegaly and thus are probably associated with thrombocytopenia. However, the prevalence and severity of thrombocytopenia are unknown in this clinical setting. Moreover, one-third of patients after balloon-occluded retrograde transvenous obliteration (BRTO have aggravated splenomegaly, which potentially may cause worsening thrombocytopenia. The aim of the study is to determine the prevalence and degree of thrombocytopenia in patients with gastric varices associated with gastrorenal shunts undergoing BRTO, to determine the prognostic factors of survival after BRTO (platelet count included, and to assess the effect of BRTO on platelet count over a 1-year period. Materials and Methods: This is a retrospective review of 35 patients who underwent BRTO (March 2008-August 2011. Pre- and post-BRTO platelet counts were noted. Potential predictors of bleeding and survival (age, gender, liver disease etiology, platelet count, model for end stage liver disease [MELD]-score, presence of ascites or hepatocellular carcinoma were analyzed (multivariate analysis. A total of 91% (n = 32/35 of patients had thrombocytopenia (90% of patients in patients undergoing BRTO. However, BRTO (with occlusion of the gastrorenal shunt has little effect on the platelet count. Long-term outcomes of BRTO for bleeding gastric varices using sodium tetradecyl sulfate in the USA are impressive with a 4-year variceal rebleed rate and transplant-free survival rate of 9% and 76%, respectively. Platelet count is not a predictor of higher rebleeding or patient survival after BRTO.

  13. Early clinical outcome and complications related to balloon kyphoplasty

    Directory of Open Access Journals (Sweden)

    Martin Bergmann

    2012-06-01

    Full Text Available The treatment of painful osteoporotic vertebral compression fractures using transpedicular cement augmentation has grown significantly over the last two decades. The benefits of balloon kyphoplasty compared to conservative treatment remain controversial and are discussed in the literature. The complication rates of vertebroplasty and kyphoplasty are considered to be low. The focus of this study was the analysis of acute and clinically relevant complications related to this procedure. In our department, all patients treated between February 2002 and February 2011 with percutaneous cement augmentation (372 patients, 522 augmented vertebral bodies were prospectively recorded. Demographic data, comorbidities, fracture types, intraoperative data and all complications were documented. The pre- and postoperative pain-level and neurological status (Frankel-Score were evaluated. All patients underwent a standardized surgical procedure. Two hundred and ninety-seven patients were treated solely by balloon kyphoplasty; 216 females (72.7% and 81 males (27.3%. Average patient age was 76.21 years (±10.71, range 35-98 years. Average American Society Anestesiologists score was 3.02. According to the Orthopedic Trauma Association classification, there were 69 A 1.1 fractures, 177 A 1.2 fractures, 178 A 3.1.1 fractures and 3 A 3.1.3 fractures. Complications were divided into preoperative, intraoperative and postoperative events. There were 4 pre-operative complications: 3 patients experienced persistent pain after the procedure. In one case, the pedicles could not be visualized during the procedure and the surgery was terminated. One hundred and twenty-nine (40.06% of the patients showed intraoperative cement leaking outside the vertebras, one severe hypotension and tachycardia as reaction to the inflation of the balloons, and there was one cardiac arrest during surgery. Postoperative subcutaneous hematomas were observed in 3 cases, 13 patients developed a

  14. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  15. Five-millimeter balloon trocar site herniation: report of two cases and review of literature.

    Science.gov (United States)

    Kanis, Margaux J; Momeni, Mazdak; Zakashansky, Konstantin; Chuang, Linus; Hayes, Monica Prasad

    2013-01-01

    Trocar site herniation is a well-known potential complication of minimally invasive surgery. We present the cases of two herniations after use of 5-mm non-bladed balloon trocars. In both patients, surgical management was required, with no subsequent sequelae to date. The hernias were attributed to excessive fascial stretching and compression by the balloon. We recommend full-thickness closure of 5-mm ports if a balloon is used or if there was extensive intraoperative manipulation.

  16. Sinus Balloon Dilation as Treatment for Acute Sphenoid Sinusitis with Impaired Vision for a Child

    Directory of Open Access Journals (Sweden)

    Yin Zhao

    2016-01-01

    Full Text Available This paper is about sinus balloon dilatation in treatment of acute left sphenoid sinusitis with left impaired vision in a child. Balloon catheter dilatation (BCD of the sinus ostia is a new technique. It has been shown to be a minimally invasive technique to manage chronic sinusitis. However, this method is rarely used in the treatment of acute sinusitis. So far, we know of no reported cases of sinus balloon dilatation in treatment of this case, especially for children.

  17. Planetary Balloon-Based Science Platform Evaluation and Program Implementation

    Science.gov (United States)

    Dankanich, John W.; Kremic, Tibor; Hibbitts, Karl; Young, Eliot F.; Landis, Rob

    2016-01-01

    This report describes a study evaluating the potential for a balloon-based optical telescope as a planetary science asset to achieve decadal class science. The study considered potential science achievable and science traceability relative to the most recent planetary science decadal survey, potential platform features, and demonstration flights in the evaluation process. Science Potential and Benefits: This study confirms the cost the-benefit value for planetary science purposes. Forty-four (44) important questions of the decadal survey are at least partially addressable through balloon based capabilities. Planetary science through balloon observations can provide significant science through observations in the 300 nm to 5 m range and at longer wavelengths as well. Additionally, balloon missions have demonstrated the ability to progress from concept to observation to publication much faster than a space mission increasing the speed of science return. Planetary science from a balloon-borne platform is a relatively low-cost approach to new science measurements. This is particularly relevant within a cost-constrained planetary science budget. Repeated flights further reduce the cost of the per unit science data. Such flights offer observing time at a very competitive cost. Another advantage for planetary scientists is that a dedicated asset could provide significant new viewing opportunities not possible from the ground and allow unprecedented access to observations that cannot be realized with the time allocation pressures faced by current observing assets. In addition, flight systems that have a relatively short life cycle and where hardware is generally recovered, are excellent opportunities to train early career scientists, engineers, and project managers. The fact that balloon-borne payloads, unlike space missions, are generally recovered offers an excellent tool to test and mature instruments and other space craft systems. Desired Gondola Features: Potential

  18. [The role of occlusion and extraction in orthodontics. Historical overview].

    Science.gov (United States)

    Kucsera, Agnes; Struhár, Gabriella

    2012-03-01

    Occlusion is important in each unit of dentistry. The authors describe not only the meaning of normal occlusion and dysgnathy but also the historical background focusing on the most important orthodontists, their achievements and literary works. This article gives an overview of the development of orthodontics from the very beginning (ancient times) to nowadays. The most important figures of these periods are: P. Fauchard, F. C. Kneisel, E. H. Angle, C. Case (dark ages); C. F. Ballard, P. R. Begg, C. H. Tweed (golden ages); L. F. Andrews and R. H. Roth (contemporary period). Along these three eras development and changing of the extraction-principles are shown. Nowadays the orthodontists still use Angle's classification and orthodontic treatment with extraction is also accepted. However it is not a separate treatment method, but only used as complement treatment. The authors stress on the importance of normal occlusion, which should be result of every orthodontic, but also prothetic and gnathological treatment.

  19. Low-intensity exercise, vascular occlusion, and muscular adaptations.

    Science.gov (United States)

    Teramoto, Masaru; Golding, Lawrence A

    2006-01-01

    The study investigated the effects of low-intensity exercise on muscular fitness when combined with vascular occlusion. Nineteen college male and female students performed two sets of a 5-min step exercise using a 12-inch bench three times per week for 5 weeks. During the step exercise, blood flow to one leg was restricted (vascular occlusion) with a blood pressure cuff, while the other leg was not occluded. Muscular strength of the occluded leg was significantly increased over the nonoccluded leg (p Muscular endurance and muscle mass were improved after 5 weeks of training (p 0.05). Exercise with vascular occlusion has the potential to be an alternative form of training to promote muscular strength.

  20. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    KAUST Repository

    Schott, M.

    2013-06-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  1. Retinal vein occlusion during flare of multicentric Castleman's disease

    Directory of Open Access Journals (Sweden)

    Kozak I

    2013-08-01

    Full Text Available Igor Kozak,1,2 Erin G Reid31King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia; 2University of California San Diego, Jacobs Retina Center at the Shiley Eye Center, La Jolla, CA, USA; 3University of California San Diego, Moores Cancer Center, AIDS Malignancy Consortium, La Jolla, CA, USAAbstract: We report a case of successive bilateral retinal vein occlusion in a human immunodeficiency virus (HIV-positive male with multicentric Castleman's disease treated successfully with a single injection of intravitreal bevacizumab. Castleman's disease should be a differential diagnosis of occlusive retinovascular disease and, occasionally, ocular manifestation can lead to systemic diagnosis.Keywords: retinal vein occlusion, Castleman's disease, intravitreal bevacizumab

  2. Hierarchical Template Matching for Robust Visual Tracking with Severe Occlusions

    Institute of Scientific and Technical Information of China (English)

    Lizuo Jin; Tirui Wu; Feng Liu; Gang Zeng

    2012-01-01

    To tackle the problem of severe occlusions in visual tracking, we propose a hierarchical template-matching method based on a layered appearance model. This model integrates holistic- and part-region matching in order to locate an object in a coarse-to-fine manner. Furthermore, in order to reduce ambiguity in object localization, only the discriminative parts of an object' s appearance template are chosen for similarity computing with respect to their cornerness measurements. The similarity between parts is computed in a layer-wise manner, and from this, occlusions can be evaluated. When the object is partly occluded, it can be located accurately by matching candidate regions with the appearance template. When it is completely occluded, its location can be predicted from its historical motion information using a Kalman filter. The proposed tracker is tested on several practical image sequences, and the experimental results show that it can consistently provide accurate object location for stable tracking, even for severe occlusions.

  3. Development of ultra-thin polyethylene balloons for high altitude research upto mesosphere

    CERN Document Server

    Kumar, B Suneel; Ojha, D K; Peter, G Stalin; Vasudevan, R; Anand, D; Kulkarni, P M; Reddy, V Anmi; Rao, T V; Sreenivasan, S

    2014-01-01

    Ever since its inception four decades back, Balloon Facility of Tata Institute of Fundamental Research (TIFR), Hyderabad has been functioning with the needs of its user scientists at its focus. During the early nineties, when the X-ray astronomy group at TIFR expressed the need for balloons capable of carrying the X-ray telescopes to altitudes up to 42 km, the balloon group initiated research and development work on indigenous balloon grade films in various thickness not only for the main experiment but also in parallel, took up the development of thin films in thickness range 5 to 6 microns for fabrication of sounding balloons required for probing the stratosphere up to 42 km as the regular 2000 grams rubber balloon ascents could not reach altitudes higher than 38 km. By the year 1999, total indigenisation of sounding balloon manufacture was accomplished. The work on balloon grade ultra-thin polyethylene film in thickness range 2.8 to 3.8 microns for fabrication of balloons capable of penetrating mesosphere ...

  4. High-Altitude Ballooning Program at the Indian Institute of Astrophysics

    CERN Document Server

    Nayak, A; Safonova, M; Murthy, Jayant

    2013-01-01

    We have begun a program of high altitude ballooning at the Indian Institute of Astrophysics, Bangalore. Recent advances in balloons as well as in electronics have made possible scientific payloads at costs accessible to university departments. The primary purpose of this activity is to test low-cost ultraviolet (UV) payloads for eventual space flight, but to also explore phenomena occurring in the upper atmosphere, including sprites and meteorite impacts, using balloon-borne payloads. This paper discusses the results of three tethered balloon experiments carried out at the CREST campus of IIA, Hosakote and our plans for the future. We also describe the stages of payload development for these experiments.

  5. The effects of naris occlusion on mouse nasal turbinate development.

    Science.gov (United States)

    Coppola, David M; Craven, Brent A; Seeger, Johannes; Weiler, Elke

    2014-06-15

    Unilateral naris occlusion, a standard method for causing odor deprivation, also alters airflow on both sides of the nasal cavity. We reasoned that manipulating airflow by occlusion could affect nasal turbinate development given the ubiquitous role of environmental stimuli in ontogenesis. To test this hypothesis, newborn mice received unilateral occlusion or sham surgery and were allowed to reach adulthood. Morphological measurements were then made of paraffin sections of the whole nasal cavity. Occlusion significantly affected the size, shape and position of turbinates. In particular, the nasoturbinate, the focus of our quantitative analysis, had a more delicate appearance on the occluded side relative to the open side. Occlusion also caused an increase in the width of the dorsal meatus within the non-occluded and occluded nasal fossae, compared with controls, and the position of most turbinates was altered. These results suggest that a mechanical stimulus from respiratory airflow is necessary for the normal morphological development of turbinates. To explore this idea, we estimated the mechanical forces on turbinates caused by airflow during normal respiration that would be absent as a result of occlusion. Magnetic resonance imaging scans were used to construct a three-dimensional model of the mouse nasal cavity that provided the input for a computational fluid dynamics simulation of nasal airflow. The simulation revealed maximum shear stress values for the walls of turbinates in the 1 Pa range, a magnitude that causes remodeling in other biological tissues. These observations raise the intriguing possibility that nasal turbinates develop partly under the control of respiratory mechanical forces.

  6. Primary stenting as emergency therapy in acute basilar artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Spreer, Joachim; Arnold, Sebastian; Klisch, Joachim; Schumacher, Martin [Section of Neuroradiology, University Hospital Freiburg, Breisacher Strasse 64, 79106 Freiburg (Germany); Els, Thomas; Hetzel, Andreas; Huppertz, Hans-Juergen; Oehm, Eckhardt [Department of Neurology, University Hospital Freiburg, Freiburg (Germany)

    2002-09-01

    In three patients with acute occlusion of the basilar artery intra-arterial fibrinolysis resulted in only partial recanalization and revealed severe stenosis as the underlying cause. Application of micro-stents without previous dilatation resulted in vessel re-opening. Two patients had an excellent clinical outcome. One patient died 10 days after the stroke due to brainstem infarction. Emergency primary stent application may improve the outcome in acute basilar artery occlusion, if intra-arterial thrombolysis fails to re-establish a sufficient flow. (orig.)

  7. A Case of Branch Retinal Artery Occlusion following Uneventful Phacoemulsification

    Directory of Open Access Journals (Sweden)

    Daniel Dragnev

    2013-03-01

    Full Text Available We would like to present a case of branch retinal artery occlusion following uneventful phacoemulsification, possibly caused by sub-Tenon's anaesthesia. There were no predisposing general health problems. There are two possible mechanisms: (1 mechanical effect of the bolus anaesthetic; (2 pharmacologically mediated changes in the vascular calibre. The latter mechanism is much more probable, because of the vasoconstrictive properties of both medications used. This is the first reported case of branch retinal artery occlusion after sub-Tenon's anaesthesia with preservative-free medications.

  8. Stent-based mechanical thrombectomy in acute basilar artery occlusion.

    Science.gov (United States)

    Cohen, José E; Leker, Ronen R; Moscovici, Samuel; Attia, Moshe; Itshayek, Eyal

    2011-12-01

    Stent-based mechanical thrombectomy was recently proposed as an effective alternative to other mechanical techniques to achieve recanalization of large-vessel embolic occlusions in the anterior circulation. To our knowledge, there are no reports of the use of this technique in acute basilar artery occlusion (ABAO). We present a patient with complete endovascular recanalization of ABAO using a stent-based thrombectomy technique. Advantages and limitations of this technique in the management of ABAO are discussed. The stent-thrombectomy technique is promising, and will need further evaluation in posterior circulation stroke.

  9. Endovascular Sharp Recanalization for Calcified Femoropopliteal Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Hsuan-Li Huang

    2012-01-01

    Full Text Available Endovascular intervention of peripheral chronic total occlusion (CTO is technically challenging and time consuming. Various techniques and devices are used to facilitate lesion crossing and improve the success rate of the procedure. However, these new devices are quite expensive and not readily available. We report 2 cases of peripheral CTO wherein the occlusions were successfully crossed by using stiff end of Terumo glidewire. This sharp recanalization may be a useful technique for the recanalization of calcified peripheral CTOs when conventional techniques fail and new devices are not readily available, but it is accompanied by the risk of distal atheroembolism.

  10. [Physiopathology of macular edema in central vein occlusion].

    Science.gov (United States)

    Stanca, Horia T; Manea, Georgiana

    2012-01-01

    Retinal Vein Occlusions are vascular diseases affecting the Central Retinal Vein and its branches causing decreased retinal drainage resulting in significant clinical and functional pathological changes. RVO determines the increase of vascular permeability, with edema and hemorrhage and development of collateral vessels in a few weeks. Among the serious consequences of venous occlusion is the installation of macular edema to which depends long-term visual prognosis. Macular Edema is the accumulation of intraretinal serous fluid in the macular area caused by the breakdown of blood-retinal barrier.

  11. Mortality in patients with central retinal vein occlusion

    DEFF Research Database (Denmark)

    Bertelsen, Mette; Linneberg, Allan; Christoffersen, Nynne;

    2014-01-01

    PURPOSE: To assess mortality in patients with central retinal vein occlusion (CRVO). DESIGN: Registry-based cohort study. PARTICIPANTS AND CONTROLS: Four hundred thirty-nine photographically verified CRVO patients and a control cohort of 2195 unexposed subjects matched by age and gender and alive.......03-1.56) and in women 60 to 69 years of age (SMR, 1.94; 95% CI, 1.22-3.08). CONCLUSIONS: Central retinal vein occlusion was associated with an overall increase in mortality compared with controls that was attributed statistically to cardiovascular disorders and diabetes. We recommend treatment of hypertension...

  12. Mortality in patients with branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Christoffersen, Nynne; Gade, Else; Knudsen, Lars;

    2007-01-01

    PURPOSE: To assess the impact of branch retinal vein occlusion (BRVO), a condition related to arteriolar wall thickening, as a prognostic marker of mortality. DESIGN: Long-term follow-up study comparing cases with background population. PARTICIPANTS: Patients diagnosed with BRVO. METHODS: Diagnosis...... occlusion was found in 329 patients (173 women, 156 men) born between 1902 and 1956, who were 39 to 91 years old when diagnosed between 1973 and 1998. Follow-up was concluded on July 8, 2004, when 144 deaths were recorded in patients (74 women, 70 men), compared with an expected number of 145.5 deaths...

  13. Racial differences in the distribution of anterior circulation occlusive disease.

    Science.gov (United States)

    Gorelick, P B; Caplan, L R; Hier, D B; Parker, S L; Patel, D

    1984-01-01

    We compared clinical and angiographic features of 26 white and 45 black patients with symptomatic occlusive cerebrovascular disease. White patients had more transient ischemic attacks, carotid bruits, and more severe occlusive disease of the internal carotid artery origin. Blacks had more severe disease of the middle cerebral artery stem and supraclinoid internal carotid arteries. Differences were not explained by racial differences in the prevalence of hypertension, diabetes, hypercholesterolemia, or ischemic heart disease. Since the middle cerebral artery lesions in blacks do not correlate with other accepted epidemiologic, clinical, and laboratory markers of atherosclerosis, the lesions may arise from a disorder that differs from atherosclerosis.

  14. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    Science.gov (United States)

    Kwon, Chang-Il; Lehman, Glen A.

    2016-01-01

    Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs]) have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations. PMID:27000422

  15. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio [Dokkyo Medical University Koshigaya Hospital, Department of Neurosurgery, Koshigaya, Saitama (Japan)

    2014-12-15

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  16. Sinus bradycardia as a predictor of right coronary artery occlusion in patients with inferior myocardial infarction.

    Science.gov (United States)

    Serrano, C V; Bortolotto, L A; César, L A; Solimene, M C; Mansur, A P; Nicolau, J C; Ramires, J A

    1999-01-01

    Differentiation of right coronary artery (RCA) from left circumflex artery (LCxA) occlusion may be difficult since both can present an electrocardiographic pattern of inferior myocardial infarction (IMI). We studied 133 patients with IMI, 92 patients with RCA occlusion and 41 patients with LCxA occlusion. Risk factors such as previous MI, arterial hypertension, diabetes, smoking, and dislipemia, were similar for RCA and LCxA occlusions. Patients with RCA occlusion had a higher incidence of isolated IMI than patients with LCxA occlusion, 50% vs. 17%, respectively (P<0.001). Arterial hypotension was more prevalent (P<0.05) among patients with RCA (18%) rather than those with LCxA occlusion (2%). RCA occlusion presented an association with sinus bradycardia, an association not observed with LCxA occlusion (15% vs. 0%, respectively; P<0.01). Total atrioventricular block was only present among patients with RCA (18%). Proximal occlusions of the RCA presented lower heart rates (sinus bradycardia) than medial and distal occlusions (13% vs. 1% and 1%, respectively; P<0.0001 and P<0.001). Therefore, regarding patients with IMI: (1) sinus bradycardia is more frequent when the infarct-related artery is the RCA; (2) proximal occlusions of the right coronary predispose low heart rates; and (3) occlusion of the LCxA rarely induces sinus bradycardia.

  17. Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty. A study in the atherosclerotic rabbit.

    Science.gov (United States)

    Sarembock, I J; LaVeau, P J; Sigal, S L; Timms, I; Sussman, J; Haudenschild, C; Ezekowitz, M D

    1989-10-01

    To evaluate the effect of balloon size and inflation pressure on acute and subsequent outcome following balloon angioplasty (BA), 70 New Zealand White rabbits with bilateral femoral atherosclerosis were assigned to four groups: group 1, oversized balloon, low inflation pressure (n = 35 vessels; balloon size, 3.0 mm/inflation pressure, 5 atm); group 2, oversized balloon, high inflation pressure (n = 36; 3.0 mm/10 atm); group 3, appropriate size, low inflation pressure (n = 17; 2.5 mm/5 atm); and group 4, appropriate size balloon, high inflation pressure (n = 19; 2.5 mm/10 atm). Angiograms were obtained before, 10 minutes after, and 28 days after BA and read by two blinded observers using electronic calipers. The in vivo balloon-to-vessel ratio was measured for each group. There were eight non-BA controls. Rabbits were sacrificed either immediately (n = 34) or at 28 days after BA (n = 36), with the femoral vessels pressure perfused for histologic and morphometric analysis. The latter was performed at 28 days only. Absolute angiographic diameters increased in all groups immediately after BA (p less than 0.01). Acute angiographic success, defined as greater than 20% increase in luminal diameter, was higher using high inflation pressure (group 2, 32/36 [89%] and group 4, 16/19 [84%] vs. group 1, 23/35 [66%] and group 3, 9/17 [53%]; p less than 0.05). A 3.0-mm balloon resulted in significant oversizing irrespective of inflation pressure (balloon-to-vessel ratio, 1.5 +/- 0.1 vs. 1.1 +/- 0.1 to 1, for the 2.5-mm balloon). Vessels exposed to high inflation pressure had a significantly higher incidence of mural thrombus, dissection (p less than 0.01), and medial necrosis versus low pressure (p less than 0.05). At 28 days, the rates of restenosis (defined as greater than 50% loss of initial gain) were 14/20 (70%), 11/16 (69%), 5/10 (50%), and 5/10 (50%) for groups 1 through 4 (p = NS; a trend in favor of the groups using an oversized balloon). There was an increase in the

  18. NuMED CHEATHAM-PLATINUM STENT AND BALLOON IN BALLOON DELIVERY CATHETER FOR TREATMENT OF NATIVE COARCTATION OF THE AORTA

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ COARCTATION of the aorta (CoA) is a congenital heart defect involving a narrowing of the aorta. The narrowed segment called coarctation is most likely to happen in the segment just after the aortic arch. The narrowing can be removed by surgery or sometimes by a nonsurgical balloon dilation. However, aortic coarctation may recur even after successful surgery or balloon dilation. Fortunately, coarctation can now be treated with nonsurgical balloon dilation associated with implanting a stent using cardiac catheterization. Herein we reported our experience in a 19-year-old boy with CoA who underwent successful covered Cheatham-Platinum (CP) stent implantation for the coarctation.

  19. Modeling plaque fissuring and dissection during balloon angioplasty intervention.

    Science.gov (United States)

    Gasser, T Christian; Holzapfel, Gerhard A

    2007-05-01

    Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage.

  20. Biogenic nonmethane hydrocarbon emissions estimated from tethered balloon observations

    Science.gov (United States)

    Davis, K. J.; Lenschow, D. H.; Zimmerman, P. R.

    1994-01-01

    A new technique for estimating surface fluxes of trace gases, the mixed-layer gradient technique, is used to calculate isoprene and terpene emissions from forests. The technique is applied to tethered balloon measurements made over the Amazon forest and a pine-oak forest in Alabama at altitudes up to 300 m. The observations were made during the dry season Amazon Boundary Layer Experiment (ABLE 2A) and the Rural Oxidants in the Southern Environment 1990 experiment (ROSE I). Results from large eddy simulations of scalar transport in the clear convective boundary layer are used to infer fluxes from the balloon profiles. Profiles from the Amazon give a mean daytime emission of 3630 +/- 1400 micrograms isoprene sq m/h, where the uncertainty represents the standard deviation of the mean of eight flux estimates. Twenty profiles from Alabama give emissions of 4470 +/- 3300 micrograms isoprene sq m/h, 1740 +/- 1060 micrograms alpha-pinene sq m/h, and 790 +/- 560 micrograms beta-pinene sq m/h, respectively. These results are in agreement with emissions derived from chemical budgets. The emissions may be overestimated because of uncertainty about how to incorporate the effects of the canopy on the mixed-layer gradients. The large variability in these emission estimates is probably due to the relatively short sampling times of the balloon profiles, though spatially heterogeneous emissions may also play a role. Fluxes derived using this technique are representative of an upwind footprint of several kilometers and are independent of hydrocarbon oxidation rate and mean advection.

  1. BLAST: A balloon-borne, large-aperture, submillimetre telescope

    Science.gov (United States)

    Wiebe, Donald Victor

    BLAST is a balloon-borne large-aperture, submillimetre telescope, which makes large area (1--200 square degree) surveys of Galactic and extragalactic targets. Since BLAST observes in the stratosphere, it is able to make broad-band observations between 200 mum and 550 mum which are difficult or impossible to perform from the ground. BLAST has been designed to probe star formation both in the local Galaxy and in the high redshift (z = 1--4) universe. Because BLAST is flown on an unmanned stratospheric balloon platform, it has been designed to be able to operate autonomously, without needing operator intervention to perform its scientific goals. This thesis includes an overview of the design of the BLAST platform, with emphasis on the command and control systems used to operate the telescope. BLAST has been flown on two long-duration balloon flights. The first of these, from Esrange, Sweden in June of 2005, acquired ˜70 hours of primarily Galactic data. During the second flight, from Willy Field, Antarctica in December of 2006, BLAST acquired ˜225 hours of both Galactic and extragalactic data. Operational performance of the platform during these two flights is reviewed, with the goal of providing insight on how future flights can be improved. Reduction of the data acquired by these large-format bolometer arrays is a challenging procedure, and techniques developed for BLAST data reduction are reviewed. The ultimate goal of this reduction is the generation of high quality astronomical maps which can be used for subsequent portions of data analysis. This thesis treats, in detail, the iterative, maximum likelihood map maker developed for BLAST. Results of simulations performed on the map maker to characterise its ability to reconstruct astronomical signals are presented. Finally, astronomical maps produced by this map maker using real data acquired by BLAST are presented, with a discussion on non-physical map pathologies resulting from the data reduction pipeline and

  2. Mapping white matter diffusion and cerebrovascular reactivity in carotid occlusive disease

    NARCIS (Netherlands)

    Conklin, J.; Fierstra, J.; Crawley, A. P.; Han, J. S.; Poublanc, J.; Silver, F. L.; Tymianski, M.; Fisher, J. A.; Mandell, D. M.; Mikulis, D. J.

    2011-01-01

    Objective: To characterize the relationship between cerebrovascular reactivity (CVR) and white matter (WM) diffusion in patients with internal carotid artery (ICA) occlusive disease. Methods: In this exploratory observational study, 41 patients with severe stenosis or occlusion of the extracranial I

  3. Cineangiographic findings and balloon catheter angioplasty of pulmonic valvular stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Kyung Mo; Yoon, Yong Soo; Kim, In One; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-08-15

    Transluminal balloon valvuloplasty was performed in the treatment of congenital pulmonic valvular stenosis in 55 children, aged 4 months to 15 years. The right ventricular outflow tract pressure gradient decreased significantly immediately after the procedure from 87.18 {+-} 56mmHg to 29.62 {+-} 26.48mmHg ({rho} < 0.001). Technical success rate was 98% (54/55 patients) and failed case (1 patient) was due to severe fibrous thickening of valve. Complication occurred in one case, that is tricuspid regurgitation (Grade II) due to suspected rupture of chordae tendinae. The degree of pulmonary conus dilatation was closely related with age than the pressure gradient.

  4. Pointing System for the Balloon-Borne Astronomical Payloads

    CERN Document Server

    Nirmal, K; Mathew, Joice; Sarpotdar, Mayuresh; Suresh, Ambily; Prakash, Ajin; Safonova, Margarita; Murthy, Jayant

    2016-01-01

    We describe the development and implementation of a light-weight, fully autonomous 2-axis pointing and stabilization system designed for balloon-borne astronomical payloads. The system is developed using off-the-shelf components such as Arduino Uno controller, HMC 5883L magnetometer, MPU-9150 Inertial Measurement Unit (IMU) and iWave GPS receiver unit. It is a compact and rugged system which can also be used to take images/video in a moving vehicle, or in areal photography. The system performance is evaluated from the ground, as well as in conditions simulated to imitate the actual flight by using a tethered launch.

  5. Pointing system for the balloon-borne astronomical payloads

    Science.gov (United States)

    Nirmal, Kaipacheri; Sreejith, Aickara Gopinathan; Mathew, Joice; Sarpotdar, Mayuresh; Ambily, Suresh; Prakash, Ajin; Safonova, Margarita; Murthy, Jayant

    2016-10-01

    We describe the development and implementation of a light-weight, fully autonomous 2-axis pointing and stabilization system designed for balloon-borne astronomical payloads. The system is developed using off-the-shelf components such as Arduino Uno controller, HMC 5883L magnetometer, MPU-9150 inertial measurement unit, and iWave GPS receiver unit. It is a compact and rugged system which can also be used to take images/video in a moving vehicle or in real photography. The system performance is evaluated from the ground, as well as in conditions simulated to imitate the actual flight by using a tethered launch.

  6. Computing Optimum Heights for Balloon-Borne Radar

    Science.gov (United States)

    1993-11-01

    ducting, a " radar hole" against other raytrace niodels (IREPS, could develop. Although the radar beam. EREPS) that are considered accurate. The may be...TD-1369, Naval Ocean Systems Center, San Diego, CA, October 1985. ,quires, M.F., Caribbean Basin Radar Network Raytrace Study, USAPETAC/PR-91/005...IlI-AFETAC/PR-93IoO5 * AD-A286 832 COMPUTING OPTIMUM HEIGHTS for BALLOON-BORNE RADAR by Michael F. Squires IjxEA NOVEMBER 1993 DTIC QUAI’ii E’T" 2T

  7. Balloon-borne observations of mid-latitude hydrofluoric acid

    Science.gov (United States)

    Sen, B.; Toon, G. C.; Blavier, J.-F.; Szeto, J. T.; Fleming, E. L.; Jackman, C. H.

    1995-01-01

    Measurements of stratospheric hydrofluoric acid (HF) have been made by the JPL MkIV interferometer during high-altitude balloon flights. Infrared solar absorption spectra were acquired near 35 deg N at altitudes between local tropopause and 38 km. Volume mixing ratio profiles of HF derived from 4 flights (1990-93), in conjunction with simultaneously observed N2O profiles, indicate an average rate of HF increase of (5.5 +/- 0.3)% per year, in agreement with time-dependent, two-dimensional model simulations (6% per year) and ATMOS measurements.

  8. Background Measurements from Balloon-Borne CZT Detectors

    OpenAIRE

    Jenkins, Johnathan A; Narita, Tomohiko; Grindlay, Jonathan E.; Bloser, Peter F.; Stahle, Carl; Parker, Brad; Barthelmy, Scott

    2002-01-01

    We report detector characteristics and background measurements from two prototype imaging CZT detectors flown on a scientific balloon payload in May 2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals, each with a 4 $\\times$ 4 array of pixels tiling the anode. One is made from IMARAD horizontal Bridgman CZT, the other from eV Products high-pressure Bridgman material. Both detectors were mounted side-by-side in a flip-chip configuration and read out by a 32-channel IDE...

  9. Simulation of peeling-ballooning modes with pellet injection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S. Y. [College of Physical Science and Technology, Sichuan University, 610064 Chengdu (China); Key Laboratory of High Energy Density Physics and Technology of Ministry of Education, Sichuan University, Chengdu 610064 (China); Southwestern Institute of Physics, Chengdu 610041 (China); Huang, J.; Sun, T. T.; Tang, C. J. [College of Physical Science and Technology, Sichuan University, 610064 Chengdu (China); Key Laboratory of High Energy Density Physics and Technology of Ministry of Education, Sichuan University, Chengdu 610064 (China); Wang, Z. H. [Southwestern Institute of Physics, Chengdu 610041 (China)

    2014-11-15

    The influence of pellet ablation on the evolution of peeling-ballooning (P-B) modes is studied with BOUT++ code. The atoms coming from pellet ablation can significantly reshape the plasma pressure profile, so the behaviors of P-B modes and edge localized mode (ELM) are modified dramatically. This paper shows that the energy loss associated with an ELM increases substantially over that without the pellet, if the pellet is deposited at the top of the pedestal. On the contrary, for pellet deposition in the middle of the pedestal region the ELM energy loss can be less.

  10. Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study

    Science.gov (United States)

    Dogan, Arife; Bek, Bulent

    2014-01-01

    PURPOSE The occlusal splint has been used for many years as an effective treatment of sleep bruxism. Several methods have been used to evaluate efficiency of the occlusal splints. However, the effect of the occlusal splints on occlusal force has not been clarified sufficiently. The purpose of this study was to evaluate the effect of occlusal splints on maximum occlusal force in patients with sleep bruxism and compare two type of splints that are Bruxogard-soft splint and canine protected hard stabilization splint. MATERIALS AND METHODS Twelve students with sleep bruxism were participated in the present study. All participants used two different occlusal splints during sleep for 6 weeks. Maximum occlusal force was measured with two miniature strain-gage transducers before, 3 and 6 weeks after insertion of occlusal splints. Clinical examination of temporomandibular disorders was performed for all individuals according to the Craniomandibular Index (CMI) before and 6 weeks after the insertion of splints. The changes in mean occlusal force before, 3 and 6 weeks after insertion of both splints were analysed with paired sample t-test. The Wilcoxon test was used for the comparison of the CMI values before and 6 weeks after the insertion of splints. RESULTS Participants using stabilization splints showed no statistically significant changes in occlusal force before, 3, and 6 weeks after insertion of splint (P>.05) and participants using Bruxogard-soft splint had statistically significant decreased occlusal force 6 weeks after insertion of splint (P<.05). There was statistically significant improvement in the CMI value of the participants in both of the splint groups (P<.05). CONCLUSION Participants who used Bruxogard-soft splint showed decreases in occlusal force 6 weeks after insertion of splint. The use of both splints led to a significant reduction in the clinical symptoms. PMID:24843394

  11. Gender influence on occlusal characteristics in the primary dentition

    Directory of Open Access Journals (Sweden)

    Nisha Rani Yadav

    2014-01-01

    Full Text Available Objectives: The objective of this study was to assess and discuss the influence of gender on occlusal characteristics of primary dentition. Materials and Methods: In this study, cluster randomized sampling was done to select 4-6-year-old children from Government primary schools of Farukh Nagar block, Gurgaon, Haryana, India. Children were evaluated clinically for occlusal characteristics of primary dentition such as molar relation, Canine relation, overjet, overbite, openbite, scissors bite, and crossbite. Chi-square test was used to compare the occlusal characteristics of both genders. Results: Flush terminal plane, Class I Canine relation and both primate as well as developmental spaces were found to be prevalent in the study population, in percentages of 62.4%, 67.2%, and 37.6%, respectively. It was observed that females had more spacing, distal step molar relation and increased overjet as compared to males. Males had more Class II Canine relation, crowding, openbite, overbite, and incompetent lips as compared to females. Significant differences were found between males and females w.r.t various occlusal characteristics. Conclusion: Most of the children had gender influence on malocclusion, which indicates the need for early interception or correction of malocclusion traits based on the gender of the child.

  12. Economic aspects of the detection of occlusal dentine caries

    DEFF Research Database (Denmark)

    Norlund, Anders; Axelsson, Susanna; Dahlen, Gunnar

    2009-01-01

    OBJECTIVE: To evaluate the cost of true-positive occlusal dentine caries detection in permanent molars assessed by: (I) visual-tactile examination, (II) visual-tactile examination combined with bitewing radiographs, and (III) selective radiographic examination of patients with lesions detected cl...

  13. Occlusal status in Asian male adults : Prevalence and ethnic variation

    NARCIS (Netherlands)

    Soh, J; Sandham, John; Chin, Yeen

    2005-01-01

    The purpose of this study was to determine the occlusal status in young Asian male adults of three ethnic groups. Study models of a sample of male army recruits (N = 339, age 1722 years) with no history of orthodontic treatment were assessed. The ethnic proportions of the sample were Chinese 76.1% (

  14. Acute internal carotid artery occlusion after carotid endarterectomy

    Directory of Open Access Journals (Sweden)

    Masatoshi Yunoki

    2016-09-01

    Full Text Available We report two cases of acute carotid artery (CA occlusion following carotid endarterectomy (CEA. Case 1: a 58-year-old man was admitted with transient right-sided hemiparesis. Magnetic resonance imaging (MRI and MR angiography (MRA revealed cerebral infarction in the left cerebral hemisphere and left CA stenosis. Ten days after admission, he underwent CEA. 24 h after surgery, he developed right hemiplegia. MRI and MRA demonstrated a slightly enlarged infarction and left internal carotid artery (ICA occlusion. Emergency reoperation was performed and complete recanalization achieved. The patient made a clinically significant recovery. Case 2: a 65 year-old man underwent a right-sided CEA for an asymptomatic 80% CA stenosis. 48 h after surgery, his family noticed he was slightly disorientated. MRI and MRA revealed multiple infarctions and right ICA occlusion. He was treated with antiplatelet therapy without reoperation because sufficient cross-flow from the left ICA through the anterior communicating artery was demonstrated by angiography, and his neurological symptoms were mild. His symptoms gradually alleviated and he was discharged 14 days after surgery. With ICA occlusion after CEA, immediate re-operation is mandatory with severe neurological symptoms, whereas individualized judgement is needed when the symptoms are mild.

  15. Level selection in leg amputation for arterial occlusive disease

    DEFF Research Database (Denmark)

    Holstein, P

    1982-01-01

    In 102 leg amputations for arterial occlusion including 84 below-knee (BK), 16 above-knee (AD) and 2 through-knee (TK) amputations, the amputation level was determined by means of clinical criteria. The healing results and the selection of levels were then compared with sealed preoperative measur...

  16. Pedestrian Counting with Occlusion Handling Using Stereo Thermal Cameras

    DEFF Research Database (Denmark)

    Kristoffersen, Miklas Strøm; Dueholm, Jacob Velling; Gade, Rikke;

    2016-01-01

    for pedestrian counting based on clustering and tracking of the 3D point clouds. The method is tested on two five-minute video sequences captured at a public event with a moderate density of pedestrians and heavy occlusions. The counting performance is compared to the manually annotated ground truth and shows...

  17. Left atrial appendage occlusion with the AMPLATZER Amulet device

    DEFF Research Database (Denmark)

    Tzikas, Apostolos; Gafoor, Sameer; Meerkin, David;

    2016-01-01

    AIMS: This document aims to describe a standardised methodology for performing left atrial appendage occlusion (LAAO) using the AMPLATZER Amulet device, and to provide useful tips and tricks for operators with different levels of experience. METHODS AND RESULTS: Physicians who are experts in LAAO...

  18. Left atrial appendage occlusion for stroke prevention in atrial fibrillation

    DEFF Research Database (Denmark)

    Tzikas, Apostolos; Shakir, Samera; Gafoor, Sameer;

    2015-01-01

    Aims: To investigate the safety, feasibility, and efficacy of left atrial appendage occlusion (LAAO) with the AMPLATZER Cardiac Plug (ACP) for stroke prevention in patients with atrial fibrillation (AF). Methods and results: Data from consecutive patients treated in 22 centres were collected...

  19. Central retinal vein occlusion: A patient with systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Karadžić Jelena

    2016-01-01

    Full Text Available Introduction. Scleroderma (systemic sclerosis is a severe chronic connective tissue disease, which results in involvement of numerous internal organs. Changes in the eye are the consequences of organ-specific manifestations of scleroderma or adverse effects of immunosuppressive treatment applied. Case report. We reported a 42-year-old woman with systemic sclerosis and acute deterioration of vision in the left eye, with visual acuity 0.9. After thorough clinical examination, including fluorescein angiography and optical coherence tomography, the diagnosis of nonischemic central retinal vein occlusion was made. Further biochemical, rheumatological and immunological investigation, apart from inactive systemic sclerosis, showed normal findings. Therefore, the cause of central retinal vein occlusion could only be attributed to the microvascular changes in systemic sclerosis. After three months, visual acuity deteriorated to 0.6 due to the development of cystoid macular edema. The patient received intravitreal injection of bevacizumab and after a single dose visual acuity improved to 0.9. After a 6- month follow-up, macular edema resolved and visual acuity stabilized. Conclusion. According to our knowledge and current data from the literature, central retinal vein occlusion is a rare vision threatening manifestation of scleroderma. There are only few published case reports on central vein occlusion in scleroderma patients. Examination of the ocular fundus is recommended for evaluation of vascular disease in patients with systemic sclerosis.

  20. Sealing occlusal caries lesions in adults referred for restorative treatment

    DEFF Research Database (Denmark)

    Bakhshandeh, Azam; Qvist, Vibeke; Ekstrand, Kim R

    2012-01-01

    treatment by senior lecturers at School of Dentistry, Copenhagen, Denmark were included. In case the patient had more than one occlusal caries lesion, randomization between sealing and restoration was made; otherwise, the lesion was sealed. In total, 60 resin sealants and 12 composite restorations were made...