WorldWideScience

Sample records for balloon occlusion aortography

  1. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kumita, Shin-ichiro [Nippon Medical School, Department of Radiology, Center for Advanced Medical Technology, Tokyo (Japan); Kawamoto, Chiaki [Nippon Medical School, Department of Internal Medicine, Tokyo (Japan); Uchida, Eiji [Nippon Medical School, Department of Surgery, Tokyo (Japan)

    2017-06-15

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. (orig.)

  2. Percutaneous sharp recanalization of a membranous IVC occlusion with an occlusion balloon as a needle target

    Directory of Open Access Journals (Sweden)

    Michael D. Rivers-Bowerman, MD, MSc, FRCPC

    2017-09-01

    Full Text Available A 50-year-old male with right upper quadrant symptoms and hepatic dysfunction was found to have multiple dilated hepatic veins (HVs with intrahepatic collateralization and membranous occlusion of the intrahepatic inferior vena cava (IVC consistent with primary Budd–Chiari syndrome. Venacavograms depicted drainage of the intrahepatic collaterals through a left-sided HV entering the IVC above the level of the occlusion. Sharp recanalization of the membranous IVC occlusion was performed with an occlusion balloon as a needle target under echocardiographic monitoring followed by balloon angioplasty with restoration of IVC patency. Clinical, laboratory, and venographic procedural success has been demonstrated to 9 months with minimal residual stenosis.

  3. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  4. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  5. Transcranial Doppler US as an alternative to angiography and balloon occlusion in estimating risk of carotid occlusion

    International Nuclear Information System (INIS)

    Feaster, S.H.; Powers, A.; Laws, E.R.

    1990-01-01

    This paper demonstrates the reliability of transcranial Doppler (TCD) US in the evaluation of the adequacy of collateral vessel cerebral blood flow in patients being considered for carotid ligation or occlusion. TCD was utilized in 12 patients in an attempt to study collateral vessel blood flow during endovascular balloon occlusion of a carotid artery. This was correlated with TCD measurements performed during manual carotid compression and with cerebral angiography. Changes of blood flow velocity were measured in the ipsilateral MCA and ACA. Excellent correlation was noted between the TCD measurements during manual carotid compression and actual endovascular balloon occlusion. There was also qualitative agreement with the cross-compression angiogram

  6. Aortography

    International Nuclear Information System (INIS)

    Paulin, S.

    1986-01-01

    Aortography, the radiographic demonstration of the contrast filled central large vessel from which all organ systems of the human body derive their arterial blood supply, has a long history. In 1929, the very year when W. Forssmann reported that he had passed a catheter from an arm vein into his own right atrium, dos Santos and his colleagues reported the successful performance of abdominal aortography following direct puncture of this vessel with a needle. Angiographic study of the aorta may be performed in order to quantitate the degree of aortic valve incompetence, to delineate the topography of abnormal vascular pathways related to congenital malformations, or to search for congenital malformations, or to search for congenital or acquired vascular lesions that might be the cause of systemic hypertension

  7. Balloon Occlusion Types in the Treatment of Coronary Perforation during Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Xiangfei Wang

    2014-01-01

    Full Text Available Coronary artery perforation is an uncommon complication in patients with coronary heart disease undergoing percutaneous coronary intervention. However, pericardial tamponade following coronary artery perforation may be lethal, and prompt treatment is crucial in managing such patients. Balloon occlusion and the reversal of anticoagulant activity are the common methods used to prevent cardiac tamponade by reducing the amount of bleeding. Herein, we discuss the pros and cons of currently used occlusion types for coronary perforation. Optimal balloon occlusion methods should reduce the amount of bleeding and ameliorate subsequent myocardial ischemia injury, even during cardiac surgery.

  8. Efficacy of balloon temporary occlusion and intraoperative DSA in surgically difficult aneurysm

    International Nuclear Information System (INIS)

    Ezura, Masayuki; Mizoi, Kazuo; Yoshimoto, Takashi; Takahashi, Akira.

    1993-01-01

    A digital subtraction angiographic (DSA) apparatus has been installed in one of our operating rooms since April 1987. We performed intraoperative DSA in 42 aneurysmal surgeries in 38 patients and balloon temporary occlusion in 33 surgeries. The aneurysm was on an internal carotid artery in 26 cases and on the vertebro-basilar system in 16. A heparin-coated catheter (Anthron, Toray, Tokyo), 6 french in diameter, was inserted transfemorally and was put in a parent artery under general anesthesia. A balloon was temporarily inflated to determine inflation volume. The balloon catheter was soon deflated and was drawn back into the introducing catheter to avoid developing microembolus. The patients were not systemically heparinized but the introducing catheters were slowly flushed with heparinized saline during operation. Then a craniotomy was carried out. Next DSA was performed when temporary occlusion or confirmation of clipping was necessary. In cases of balloon temporary occlusion, the operating field was not obstructed as it is when a temporary clip is used, despite adequate flow reduction of the parent artery. After DSA for confirmation of clipping adjustment of it was performed in 12 cases out of 42. No complications occurred due to use of an introducing or a balloon catheter. We conclude that combined intravascular and neurosurgical approach, particularly for the large aneurysms with the difficulty of proximal control, can be a useful method of treatment. (author)

  9. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu [University of Virginia Health System, Department of Radiology and Medical Imaging (United States); Nambiar, Ashwin, E-mail: uvashwin@gmail.com [SUNY Downstate Medical Center, Department of Radiology (United States); Hagspiel, Lauren M., E-mail: lmh4gg@virginia.edu [University of Virginia, College of Arts and Sciences (United States); Ahmad, Ehab Ali, E-mail: ehabradiodiagnosis@yahoo.com [Minia University, Department of Radiology (Egypt); Bozlar, Ugur, E-mail: ubozlar@yahoo.com [Gulhane Military Medical Academy, Department of Radiology (Turkey)

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Five arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.

  10. Percutaneous Treatment of Intrahepatic Biliary Leak: A Modified Occlusion Balloon Technique

    Energy Technology Data Exchange (ETDEWEB)

    Nasser, Felipe; Rocha, Rafael Dahmer, E-mail: rafaeldrocha@gmail.com; Falsarella, Priscila Mina; Motta-Leal-Filho, Joaquim Maurício da; Azevedo, André Arantes; Valle, Leonardo Guedes Moreira; Cavalcante, Rafael Noronha; Garcia, Rodrigo Gobbo; Affonso, Breno Boueri; Galastri, Francisco Leonardo [Hospital Israelita Albert Einstein, Department of Interventional Radiology (Brazil)

    2016-05-15

    PurposeTo report a novel modified occlusion balloon technique to treat biliary leaks.MethodsA 22-year-old female patient underwent liver transplantation with biliary-enteric anastomosis. She developed thrombosis of the common hepatic artery and extensive ischemia in the left hepatic lobe. Resection of segments II and III was performed and a biliary-cutaneous leak originating at the resection plane was identified in the early postoperative period. Initial treatment with percutaneous transhepatic drainage was unsuccessful. Therefore, an angioplasty balloon was coaxially inserted within the biliary drain and positioned close to the leak.ResultsThe fistula output abruptly decreased after the procedure and stopped on the 7th day. At the 3-week follow-up, cholangiography revealed complete resolution of the leakage.ConclusionThis novel modified occlusion balloon technique was effective and safe. However, greater experience and more cases are necessary to validate the technique.

  11. Temporary balloon occlusion as therapy for uncontrollable arterial hemorrhage in multiply injured patients

    International Nuclear Information System (INIS)

    Rieger, J.; Linsenmaier, U.; Rock, C.; Pfeifer, K.J.; Euler, E.

    1999-01-01

    Purpose: Presentation of temporary balloon occlusion as an interventional radiological method for managing hemorrhage in multiply injured patients with uncontrollable loss of blood. Method: Temporary, non-selective arterial occlusion by introduction of a balloon catheter contralaterally to the source of bleeding has been performed since 1992 on 7 patients with multiple injuries, hemorrhagic shock requiring reanimation, and angiographic demonstration of an arterial hemorrhage in the supply region of the internal iliac artery with complex pelvic fracture. In each case a PTA balloon catheter was introduced transfemorally, non-selectively positioned proximal to the bleeding source, and left in place for 24-48 h under manometric control. Control angiographies were performed prior to catheter removal. Results: The bleeding was stopped immediately in all 7 patients. The hemodynamic stability made transport and thus further surgical management and/or a short-term treatment in the intensive-care station possible. Control angiographies confirmed that the bleeding had stopped in all patients. Conclusions: We recommend temporary balloon occlusion as a rapid and effective method for the management of bleeding in otherwise uncontrollable traumatic hemorrhages in the supply region of the internal iliac artery. (orig.) [de

  12. Clinical experience of cerebral protection with balloon occlusion during carotid artery stenting

    International Nuclear Information System (INIS)

    Jaeger, H.J.; Mathias, K.D.; Drescher, R.; Bockisch, G.; Hauth, E.; Demirel, E.; Gissler, H.M.; Witten/Herdecke Univ.

    2001-01-01

    Purpose: To asses the technical feasibility and the results of cerebral protection with the GuardWire Plus Temporary Occlusion and Aspiration System during carotid artery stenting for high-grade stenosis. Patients and Methods: In 20 patients 20 carotid artery stenoses were treated with stent placement under cerebral protection. A contralateral carotid occlusion was an exclusion criteria for the use of the protection device. In all cases only aspiration, but no flushing was used before deflation of the occlusion balloon. In 17 of 20 patients diffusion-weighted (DW-)MRT imaging of the brain was performed before and 24 hours after the procedure. Results: The stent implantation was successfully performed in all patients. In 3 patients neurologic symptoms occurred during the occlusion time. In these 3 patients the symptoms immediately disappeared after deflation of the balloon. In one case there was dilatation of the internal carotid artery at the site of the balloon inflation. In 3 of the 17 DW-MR images new ipsilateral cerebral lesions, in one case a new contralateral lesion occurred after the procedure. Conclusions: The cerebral protection procedure is technically feasible. The occlusion of the internal carotid artery was not tolerated by all patients. The DW-MR imaging demonstrated cerebral lesions indicating the occurrence of cerebral microemboli during the procedure. Further investigations are necessary to determine if the use of the cerebral protection device will improve the results of the carotid artery stenting for high-grade stenoses. (orig.) [de

  13. Acute occlusion of the coronary artery after transluminal balloon coronary angioplasty

    International Nuclear Information System (INIS)

    Savchenko, A.P.; Matchin, Yu.G.; Lyakishev, A.A.

    1995-01-01

    The research was aimed at elucidation of the relationship of the clinical and angiographic factors, on the one hand, and development of acute occlusion following transluminal balloon coronary angioplasty TBCA, on the other. TBCA was carried out in 162 patients. Eight (4.9 %) patients developed acute occlusion of the coronary artery, which was complicated by acute myocardial infarction in 50 % cases. 35 refs.; 4 tabs

  14. Balloon catheter disruption of thrombus in conjunction with thrombolysis for the treatment of acute middle cerebral artery occlusion

    International Nuclear Information System (INIS)

    Liu Zhensheng; Wang Wei; Zhang Xinjiang; Fu Changbiao; Zhou Longjiang

    2009-01-01

    Objective: To assess the feasibility, safety, and efficacy of balloon disruption of thrombus by using a deflated balloon catheter combined with intra-arterial thrombolysis for the treatment of acute middle cerebral artery (MCA) occlusion. Methods: Five consecutive patients with acute MCA occlusion underwent balloon disruption combined with intra-arterial thrombolysis. The microballoon was inflated in the distal carotid artery and then deflated and advanced just distal to the occlusion site in the MCA. Thereafter, intra- arterial thrombolysis of the MCA was applied and the maximum dosage of urokinase was 500,000 U. Results: Complete recanalization was achieved in 3 patients and partial recanalization in 2. All patients got favourable clinical outcome. There was no major intracerebral hemorrhage. Conclusion: The penetration of the MCA with a deflated balloon catheter combined with an intra-arterial thrombolysis may be a safe and effective treatment for acute ischemic stroke. (authors)

  15. Balloon Occlusion of the Contralateral Iliac Artery to Assist Recanalization of the Ipsilateral Iliac Artery in Total Aortoiliac Occlusion: A Technical Note

    Directory of Open Access Journals (Sweden)

    Abdel Aziz A. Jaffan

    2013-01-01

    Full Text Available Endovascular recanalization of chronic total aortoiliac occlusion is technically challenging. Inability to reenter the true aortic lumen, following retrograde iliac recanalization, is one of the most common causes of failure. We describe a case of a total aortoiliac occlusion where balloon occlusion of the right common iliac artery, following its recanalization from a brachial approach, was used to facilitate antegrade recanalization of the occluded contralateral left common iliac artery.

  16. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    International Nuclear Information System (INIS)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki; Ohishi, Sonomi; Nojiri, Yoko; Ogata, Hitoshi

    2001-01-01

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source

  17. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    Science.gov (United States)

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  18. The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

    International Nuclear Information System (INIS)

    Ilic, Nikola; Davidovic, Lazar; Koncar, Igor; Dragas, Marko; Markovic, Miroslav; Colic, Momcilo; Cinara, Ilijas

    2011-01-01

    Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographic evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.

  19. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  20. Outcome of Pregnancies After Balloon Occlusion of the Infrarenal Abdominal Aorta During Caesarean in 230 Patients With Placenta Praevia Accreta

    International Nuclear Information System (INIS)

    Wu, Qinghua; Liu, Zhuan; Zhao, Xianlan; Liu, Cai; Wang, Yanli; Chu, Qinjun; Wang, Xiaojuan; Chen, Zhimin

    2016-01-01

    PurposeTo explore the efficacy and safety of prophylactic temporary balloon occlusion of the infrarenal abdominal aorta during caesarean for the management of patients with placenta praevia accreta.MethodsTwo hundred and sixty-eight cases of placenta praevia accreta from January 2012 to June 2015 were retrospectively reviewed. Group A included two hundred and thirty patients who underwent prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section. Group B included thirty-eight patients who underwent caesarean without endovascular intervention. The parameters including operating room time, estimated blood loss, blood transfusion volume, PT (prothrombin time) during operation, days in the intensive care unit, and total hospital days were compared between the two groups.ResultsThe operating room time, estimated blood loss, PT, the incidence of hysterectomy, blood transfusion volume, postpartum haemorrhage, and days in intensive care unit were lower in group A than in group B, with statistical significance (P   0.05). No patient in the group with prophylactic temporary balloon occlusion of the infrarenal abdominal aorta was performed hysterectomy, while three patients in group B were performed hysterectomy because of uncontrollable haemorrhage.ConclusionsThe results indicate that prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section is safe and effective to control intraoperative blood loss and greatly decreases the risk of hysterectomy in patients with placenta praevia accreta.

  1. Physiologic Tolerance of Descending Thoracic Aortic Balloon Occlusion in a Swine Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-01-10

    Endovascular proximal control of ruptured abdominal aortic aneurysms: the internal aortic clamp. J Cardiovasc Surg (Torino) 2009;50(3):381. 14. Arthurs Z...Starnes B, See C, Andersen C. Clamp Before You Cut: Proximal Control of Ruptured Abdominal Aortic Aneurysms Using Endovascular Balloon Occlusion

  2. Caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation for the management of placenta accreta

    International Nuclear Information System (INIS)

    Duan, X.-H.; Wang, Y.-L.; Han, X.-W.; Chen, Z.-M.; Chu, Q.-J.; Wang, L.; Hai, D.-D.

    2015-01-01

    Aim: To determine the efficacy and safety of caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation (UAE) for the treatment of patients with placenta accreta. Materials and methods: This retrospective study involved 42 patients with placenta accreta. All patients underwent caesarean section combined with temporary aortic balloon occlusion followed by UAE through the right femoral approach. Results: All patients were confirmed to have placenta praevia and accreta, including five patients with placenta percreta, at the time of delivery. The technical success rate of the combined treatment was 97.6% (41/42). Forty-one patients underwent successful caesarean section with conservation of the uterus. Hysterectomy was required in one (3.1%) patient. The amount of blood loss and blood transfusion, and the operation time were was 586 ± 355 ml, 422 ± 83 ml and 65.5 ± 10.6 minutes, respectively. The mean postoperative hospital stay, occlusion time and fetal radiation dose were 5.5 ± 2.6 days, 22.4 ± 7.2 minutes and 4.2 ± 2.9 mGy, respectively. There were no significant changes before and 7 days after the endovascular procedure in creatinine levels (56.8 ± 13.8 μmol/l versus 63.4 ± 16.7 μmol/l, p = 0.09) or urea nitrogen (6.3 ± 2.5 μmol/l versus 7.4 ± 3.8 μmol/l, p = 0.17). There were no access-site complications after the endovascular procedure and no complications related to the intervention during follow-up. Conclusion: Temporary aortic balloon occlusion followed by UAE can effectively control postpartum haemorrhage during placental dissection, and reduce transfusion requirements, hysterectomy rate, and operation time in patients with placenta accreta. -- Highlights: •Aortic balloon occlusion can overcome the collateral flow from other arteries. •UAE can effectively manage secondary postpartum haemorrhage. •The aortic balloon can rapidly and easily insert. •The mean

  3. Outcome of Pregnancies After Balloon Occlusion of the Infrarenal Abdominal Aorta During Caesarean in 230 Patients With Placenta Praevia Accreta

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Qinghua, E-mail: qh-wu77@163.com [The First Affiliated Hospital of Zhengzhou University, Departments of Prenatal Diagnosis, and Obstetrics, Obstetric Critical Treatment Center of Henan Province (China); Liu, Zhuan, E-mail: liuchuan2015ck@163.com; Zhao, Xianlan, E-mail: zxl121292014@163.com; Liu, Cai, E-mail: liucai2015ck@163.com [The First Affiliated Hospital of Zhengzhou University, Obstetric Critical Treatment Center of Henan Province, Department of Obstetrics (China); Wang, Yanli, E-mail: wangyanli2015yfy@163.com; Chu, Qinjun, E-mail: chuqinjun2015@163.com [The First Affiliated Hospital of Zhengzhou University, Department of Anesthesiology (China); Wang, Xiaojuan, E-mail: wangxiaojun2015ck@163.com; Chen, Zhimin, E-mail: chenzhimin2015ck@163.com [The First Affiliated Hospital of Zhengzhou University, Obstetric Critical Treatment Center of Henan Province, Department of Obstetrics (China)

    2016-11-15

    PurposeTo explore the efficacy and safety of prophylactic temporary balloon occlusion of the infrarenal abdominal aorta during caesarean for the management of patients with placenta praevia accreta.MethodsTwo hundred and sixty-eight cases of placenta praevia accreta from January 2012 to June 2015 were retrospectively reviewed. Group A included two hundred and thirty patients who underwent prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section. Group B included thirty-eight patients who underwent caesarean without endovascular intervention. The parameters including operating room time, estimated blood loss, blood transfusion volume, PT (prothrombin time) during operation, days in the intensive care unit, and total hospital days were compared between the two groups.ResultsThe operating room time, estimated blood loss, PT, the incidence of hysterectomy, blood transfusion volume, postpartum haemorrhage, and days in intensive care unit were lower in group A than in group B, with statistical significance (P < 0.05). There was no significant difference in the Apgar scores of the neonates and the incidences of thrombosis in lower limbs between the two groups (P > 0.05). No patient in the group with prophylactic temporary balloon occlusion of the infrarenal abdominal aorta was performed hysterectomy, while three patients in group B were performed hysterectomy because of uncontrollable haemorrhage.ConclusionsThe results indicate that prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section is safe and effective to control intraoperative blood loss and greatly decreases the risk of hysterectomy in patients with placenta praevia accreta.

  4. Balloon-Assisted Occlusion of the Internal Iliac Arteries in Patients with Placenta Accreta/Percreta

    International Nuclear Information System (INIS)

    Bodner, Leonard J.; Nosher, John L.; Gribbin, Christopher; Siegel, Randall L.; Beale, Stephanie; Scorza, William

    2006-01-01

    Background. Placenta accreta/percreta is a leading cause of third trimester hemorrhage and postpartum maternal death. The current treatment for third trimester hemorrhage due to placenta accreta/percreta is cesarean hysterectomy, which may be complicated by large volume blood loss. Purpose. To determine what role, if any, prophylactic temporary balloon occlusion and transcatheter embolization of the anterior division of the internal iliac arteries plays in the management of patients with placenta accreta/percreta. Methods. The records of 28 consecutive patients with a diagnosis of placenta accreta/percreta were retrospectively reviewed. Patients were divided into two groups. Six patients underwent prophylactic temporary balloon occlusion, followed by cesarean section, transcatheter embolization of the anterior division of the internal iliac arteries and cesarean hysterectomy (n = 5) or uterine curettage (n = 1). Twenty-two patients underwent cesarean hysterectomy without endovascular intervention. The following parameters were compared in the two groups: patient age, gravidity, parity, gestational age at delivery, days in the intensive care unit after delivery, total hospital days, volume of transfused blood products, volume of fluid replacement intraoperatively, operating room time, estimated blood loss, and postoperative morbidity and mortality. Results. Patients in the embolization group had more frequent episodes of third trimester bleeding requiring admission and bedrest prior to delivery (16.7 days vs. 2.9 days), resulting in significantly more hospitalization time in the embolization group (23 days vs. 8.8 days) and delivery at an earlier gestational age than in those in the surgical group (32.5 weeks). There was no statistical difference in mean estimated blood loss, volume of replaced blood products, fluid replacement needs, operating room time or postoperative recovery time. Conclusion. Our findings do not support the contention that in patients with

  5. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    Science.gov (United States)

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  6. Resuscitative endovascular balloon occlusion of the aorta: promise, practice, and progress?

    Science.gov (United States)

    Perkins, Zane B; Lendrum, Robbie A; Brohi, Karim

    2016-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a minimally invasive damage control procedure for life-threatening abdominal or pelvic haemorrhage. The purpose of this review is to summarize the current understanding and experience with REBOA, outline potential future applications of this technology, and highlight priority areas for further research. REBOA is a feasible method of achieving temporary aortic occlusion and can be performed rapidly, with a high degree of success, in the emergency setting (including at the scene of injury) by appropriately trained clinicians. The procedure supports central perfusion, controls noncompressible haemorrhage, and may improve survival in certain profoundly shocked patient groups; but is also associated with significant risks, including ischaemic tissue damage and procedural complications. Evolutions of this strategy are being explored, with promising proof-of-concept studies in the fields of partial aortic occlusion and the combination of REBOA with extracorporeal support. Noncompressible torso haemorrhage is the leading cause of preventable trauma deaths. The majority of these deaths occur soon after injury, often before any opportunity for definitive haemorrhage control. For a meaningful reduction in trauma mortality, novel methods of rapid haemorrhage control are required.

  7. Evaluation of results and radiologic follow-up in detachable balloon occlusion therapy of the internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Chung, Sun Yang; Kim, Dong Ik; Lee, Kyu Chang; Huh, Seung Kon; Yoon, Pyeong Ho; Choi, Jin Young; Kim, Dong Jun

    1999-01-01

    The author has studied the clinical results of CT and MR findings of proximal carotid artery occlusion using detachable balloons in the treatement of unclippable internal carotid (IC) aneurysms. From 1987 to 1995, twenty-eight patients with IC aneurysms were treated by proximal artery occlusion with detachable balloons. Of these patients, 4 had aneurysms arising from the supraclinoid portion of the IC artery, 23 had aneuryms arising from cavernous portion of the IC artery, and one had aneurysm arising from cervical portion of the IC artery. Of the 28 patients, 7 patients without CT or MR examinations were excluded in this study. The mean follow-up period was 18.6 months. The causes of aneurysm formation were spontaneous in 17 cases and traumatic in 4 cases. Of 20 patients with aneurysms arising from supraclinoid and cavernous portion of the IC artery, 16 patients (80%) had cranial nerve symptoms by mass effect. Five patients had epistaxis (3 patient), carotid cavernous fistula (1 patient) or subarachnoid hemorrhage (1 patient) due to aneurysm rupture. Two patients, each with aneuryms arising from supraclinoid and cervical portion of carotid artery had 9th and 12th cranial nerve symptom. There were three instances of complication after permanent occlusion; two patients had subarachnoid and intracerebral hemorrhage by aneurysm rupture and expired. One patient had ischemia of posterior cerebral artery teritorry after one day. Delayed ischemic event did not occur during the follow-up period. All aneurysms of the carotid artery below the level of ophthalmic artery presented radiographic proof of complete thrombosis within two months. However, complete thrombosis of aneurysm was considerably delayed in two aneurysms arising from the supraclinoid portion of the carotid artery. In long-term follow-up study, completely thrombosed aneurysms decreased in size slowly. But incompletely thrombosed aneurysms did not decrease in size for a long time and began to contract after

  8. Evaluation of results and radiologic follow-up in detachable balloon occlusion therapy of the internal carotid artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Sun Yang; Kim, Dong Ik; Lee, Kyu Chang; Huh, Seung Kon; Yoon, Pyeong Ho; Choi, Jin Young; Kim, Dong Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-06-01

    The author has studied the clinical results of CT and MR findings of proximal carotid artery occlusion using detachable balloons in the treatement of unclippable internal carotid (IC) aneurysms. From 1987 to 1995, twenty-eight patients with IC aneurysms were treated by proximal artery occlusion with detachable balloons. Of these patients, 4 had aneurysms arising from the supraclinoid portion of the IC artery, 23 had aneuryms arising from cavernous portion of the IC artery, and one had aneurysm arising from cervical portion of the IC artery. Of the 28 patients, 7 patients without CT or MR examinations were excluded in this study. The mean follow-up period was 18.6 months. The causes of aneurysm formation were spontaneous in 17 cases and traumatic in 4 cases. Of 20 patients with aneurysms arising from supraclinoid and cavernous portion of the IC artery, 16 patients (80%) had cranial nerve symptoms by mass effect. Five patients had epistaxis (3 patient), carotid cavernous fistula (1 patient) or subarachnoid hemorrhage (1 patient) due to aneurysm rupture. Two patients, each with aneuryms arising from supraclinoid and cervical portion of carotid artery had 9th and 12th cranial nerve symptom. There were three instances of complication after permanent occlusion; two patients had subarachnoid and intracerebral hemorrhage by aneurysm rupture and expired. One patient had ischemia of posterior cerebral artery teritorry after one day. Delayed ischemic event did not occur during the follow-up period. All aneurysms of the carotid artery below the level of ophthalmic artery presented radiographic proof of complete thrombosis within two months. However, complete thrombosis of aneurysm was considerably delayed in two aneurysms arising from the supraclinoid portion of the carotid artery. In long-term follow-up study, completely thrombosed aneurysms decreased in size slowly. But incompletely thrombosed aneurysms did not decrease in size for a long time and began to contract after

  9. Balloon occlusion of the internal carotid artery in 40 cases of giant intracavernous aneurysm: Technical aspects, cerebral monitoring, and results

    International Nuclear Information System (INIS)

    Vazquez Anon, V.; Aymard, A.; Gobin, Y.P.; Casasco, A.; Rueffenacht, D.; Khayata, M.H.; Merland, J.J.; Abizanda, E.; Redondo, A.

    1992-01-01

    We have studied the results of carotid occlusion in the treatment of giant intracavernous carotid artery (ICA) aneurysms in 40 patients. Clinical, angiographic, Doppler and cerebral blood flow (CBF) criteria for tolerance of occlusion are discussed. The patients had headaches (47.5%), cranial nerve compression (87.5%), decreased visual acuity (20%), ruptured aneurysm (15%) and 5% were asymptomatic. Balloon occlusion tests were performed under light sedation anaesthesia; a successful test required perfect clinical tolerance and adequate angiographic collateral circulation in arterial, parenchymatous, and venous phases. Additional criteria included xenon 133 CBF measurements, and transcranial Doppler sonography of the middle cerebral artery. According to these criteria, 5 patients did not tolerate test occlusion and required an extra-intracranial (EC-IC) bypass. Mean follow-up was 4.7 years. All patients were radiologically cured of their aneurysm, and in 35 the symptoms resolved, although 3 had persistent ocular motor nerve palsies, and in 4 visual defects were unchanged. Complications were 1 permament and 3 transient neurological deficits. Balloon occlusion of the ICA is an effective, reliable form of treatment for intracavernous giant aneurysm and should replace surgical ligation of the cervical carotid artery. With CBF or Doppler monitoring, the risk of neurological deficit is diminished. EC-IC bypass prior to ICA occlusion is indicated if test occlusion is not tolerated. (orig.)

  10. Prophylactic balloon occlusion of internal iliac arteries in women with placenta accreta: Literature review and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dilauro, M.D.; Dason, S. [McMaster University, Michael G. DeGroote School of Medicine (Canada); Athreya, S., E-mail: sathreya@stjoes.ca [Diagnostic Imaging, St Joseph' s Healthcare Hamilton, Ontario (Canada)

    2012-06-15

    Aim: To review the literature on the use of prophylactic balloon occlusion alone and in conjunction with arterial embolization of the internal iliac arteries in women with placenta accreta. Materials and methods: The PubMed, MEDLINE, CINAHL, EMBASE, and Cochrane Library databases were searched for keywords related to this technique and its use in the avoidance of caesarean hysterectomy. The relevant published articles were selected and then searched for further references. Results: The literature search found 15 case reports and five studies for a total of 20 articles. The use of balloon catheters to prevent post-partum haemorrhage in women with placenta accreta is controversial with some investigators reporting reduced blood loss and transfusion requirements while others reporting no benefit. This procedure does not appear to reduce operative time or hospital stay. Some groups have described catheter-related complications, such as maternal thromboembolic events and the need for stent placement and/or arterial bypass. Thus far, there is no reported maternal or foetal mortality related to this procedure. Conclusion: Current evidence is based upon case reports and small retrospective studies. Larger studies or randomized controlled trials are essential in order to demonstrate the safety and efficacy of bilateral iliac balloon occlusion. The creation of a data registry would also facilitate the reporting of this technique.

  11. CT angiography. Abdominal CT using intravenous aortography for contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, J; Nakauma, Y; Egawa, J; Kawamura, M [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1980-04-01

    To obtain imaging effects close to those of abdominal aortography and investigate a technique with little invasion to patients, intravenous aortography was applied to contrast enhancement (CE) in abdominal CT, and its usefulness was discussed. Intravenous aortography could clearly visualize lesions with rich neovascularity such as hepatocellular carcinoma and renal cell carcinoma. Differing from a drip infusion method, this method has complexities in its technique that contrast medium is injected at once, blood circulation time which is represented by the time between the injection and the time when the patients feel bitterness (10 - 12 seconds) must be measured before CE, and scanning begins 2 seconds before the patients feel bitterness. However, the invasion to patients due to this method is slight, and the capacity of this method to visualize neovascularity is superior to CE by a drip infusion method. Therefore, qualitative diagnosis by CT will be improved by using this method together with a drip infusion method.

  12. Clinical application of preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta in the resection of sacral tumors

    International Nuclear Information System (INIS)

    Chen Wenhua; Wang Qi; He Zhongming; Zhou Jian; Wang Yimin; Wang Jie

    2012-01-01

    Objective: To investigate the clinical application of preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta in performing the surgical resection of sacral tumors. Methods: Conventional surgical excision of sacral tumors was employed in 24 patients with sacral tumors (control group), while preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta was carried out in 32 patients with sacral tumors (study group). The operation time, blood loss during the surgery and the one-year recurrence rate of both groups were documented, and the results were statistically analyzed. Results: Angiography showed that in the study group the sacral tumors were supplied by several vessels, and these feeding arteries were occluded separately. The tumors were successfully removed in all patients with the help of intraoperative balloon occlusion of the abdominal aorta. During the surgery, the surgical area was clearly exposed and the blood loss wa remarkably reduced. After the surgery, no ectopic vascular embolization, renal ischemia, limb ischemia or other complications occurred. Statistically significant difference in the operation time, blood loss during the surgery and the one-year recurrence rate existed between the two groups (P<0.05). Conclusion: Preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta can effectively shorten the operation time, reduce the blood loss during the surgery and provide a clear surgical field, and thus the surgical safety can be significantly ensured. (authors)

  13. Survey of 200 cases of the abdominal aortography

    International Nuclear Information System (INIS)

    Kim, Ki Jeung; Choi, Doo Suk; Hah, Hae Koo

    1972-01-01

    From 1962 to 1970 about 200 abdominal aortographies were performed in Department of Radiology of National Medical Center, Seoul, Korea, with percutaneous retrograde seldinger catheterization technique. The 200 cases of the abdominal aortography were analyzed as followings. 1) The sex ratio of all patients was 105 (52.5%) males to 95 (47.5%) females. And high incidence was noted in middle age group. (46 patients were from 30 years to 40 years of age) 2) Radiological findings were grouped as 62 (31%) vascular lesion, 113 (56.5%) visceral or other expanding lesions and 29 (14.5%) angiographically nonspecific findings. Total is over 200 due to double lesions in 4 patients. 3) The 62 vascular lesions were composed of 40 aortitis, 28 renal hypertension etc. a) The 40 aortitis was divided into 25 artherosclerotic and 15 nonspecific. The 15 nonspecific aortitis revealed segmental narrowing (2-4 cm) with collaterals. b) In 28 renal hypertension, 17 cases were combined with aortitis, but not in 11 cases (Pure renal hypertension), and 19 cases were unilateral. 4) The highest incidence in 113 (56.5%) visceral or other expanding lesions, was renal lesions (88 cases), and other lesions, such as 12 retroperitoneal masses, 9 liver and pancreatic masses were also noted. The 88 renal lesions were composed of 37 renal tbc, 17 hydronephrosis (excluding tbc hydro), Tumors, 10 cyst etc. a) The most significant findings of renal tuberculosis in renal arteriogrpahy was rarefaction of contrast staining in involved area which was noted in 32 cases (87%) out of 37 renal Tuberculosis. b) All 12 hypernephroma, 1 wilm's tumor, metastaic tumor from fibromyomata uteri revealed pathological vessels and tumor stainings, however these findings were not noted in 2 ureteral carcinoma involving renal pelvis. 5) No permanent complications arose after abdominal aortography. (Percutaneous retrograde seldinger catheterization technique) 6) Abdominal aortography and selective visceral injections gave more

  14. Survey of 200 cases of the abdominal aortography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Jeung; Choi, Doo Suk; Hah, Hae Koo [National Medical Center, Seoul (Korea, Republic of)

    1972-12-15

    From 1962 to 1970 about 200 abdominal aortographies were performed in Department of Radiology of National Medical Center, Seoul, Korea, with percutaneous retrograde seldinger catheterization technique. The 200 cases of the abdominal aortography were analyzed as followings. 1) The sex ratio of all patients was 105 (52.5%) males to 95 (47.5%) females. And high incidence was noted in middle age group. (46 patients were from 30 years to 40 years of age) 2) Radiological findings were grouped as 62 (31%) vascular lesion, 113 (56.5%) visceral or other expanding lesions and 29 (14.5%) angiographically nonspecific findings. Total is over 200 due to double lesions in 4 patients. 3) The 62 vascular lesions were composed of 40 aortitis, 28 renal hypertension etc. a) The 40 aortitis was divided into 25 artherosclerotic and 15 nonspecific. The 15 nonspecific aortitis revealed segmental narrowing (2-4 cm) with collaterals. b) In 28 renal hypertension, 17 cases were combined with aortitis, but not in 11 cases (Pure renal hypertension), and 19 cases were unilateral. 4) The highest incidence in 113 (56.5%) visceral or other expanding lesions, was renal lesions (88 cases), and other lesions, such as 12 retroperitoneal masses, 9 liver and pancreatic masses were also noted. The 88 renal lesions were composed of 37 renal tbc, 17 hydronephrosis (excluding tbc hydro), Tumors, 10 cyst etc. a) The most significant findings of renal tuberculosis in renal arteriogrpahy was rarefaction of contrast staining in involved area which was noted in 32 cases (87%) out of 37 renal Tuberculosis. b) All 12 hypernephroma, 1 wilm's tumor, metastaic tumor from fibromyomata uteri revealed pathological vessels and tumor stainings, however these findings were not noted in 2 ureteral carcinoma involving renal pelvis. 5) No permanent complications arose after abdominal aortography. (Percutaneous retrograde seldinger catheterization technique) 6) Abdominal aortography and selective visceral injections gave more

  15. [Iliac artery occlusion balloons for suspected placenta accreta during cesarean section].

    Science.gov (United States)

    Burgos Frías, N; Gredilla, E; Guasch, E; Gilsanz, F

    2014-02-01

    Massive obstetric hemorrhage still remains a major cause of maternal mortality and morbidity. The risk factors associated with this pathology must be identified in order to schedule the appropriate delivery with the necessary resources. A case is presented of an iliac artery occlusion with intravascular balloons for suspected placenta accreta during cesarean section. The perioperative treatment, as well as an analysis of the treatment options is described, along with their advantages and disadvantages, from the use of postpartum hemorrhage protocols, blood transfusion and procoagulant factors, and other maneuvers to control bleeding, until the hysterectomy. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  16. Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimatsu, Rika [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan); Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp [Kochi University, Department of Radiology (Japan); Ishikawa, Masaki; Kajiwara, Kenji [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan); Aikata, Hiroshi; Chayama, Kazuaki [Hiroshima University, Department of Gastroenterology and Metabolism, Institute of Biomedical and Health Sciences (Japan); Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan)

    2016-06-15

    PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumor enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.

  17. Super-selective Balloon Test Occlusion of the Posterior Communicating Artery in the Treatment of a Posterior Cerebral Artery Fusiform Aneurysm: a Case Report.

    Science.gov (United States)

    Isozaki, Makoto; Arai, Hiroshi; Neishi, Hiroyuki; Kitai, Ryuhei; Kikuta, Ken-Ichiro

    2016-10-01

    We report the case of a 49-year-old man with underlying hypertension who developed diplopia lasting 2 months. Magnetic resonance imaging and digital subtraction angiography showed multi-lobular unruptured aneurysms in the P2 portion of the posterior cerebral artery (PCA) migrating into the interpeduncular cistern of the midbrain. Because the shapes of the aneurysms were serpentine fusiform and the posterior communicating artery (PCoA) was the fetal type, we planned anastomosis of the occipital artery to the P4 portion of the PCA followed by endovascular obliteration of the parent artery including the aneurysms. Endovascular treatment was performed via a femoral approach one week after the anastomosis. Super-selective balloon test occlusion (BTO) of the PCoA was performed by using an occlusion balloon microcatheter before endovascular treatment. Occlusion of the proximal segment of the PCoA induced disturbance of consciousness of the patient. Occlusion of the distal segment other than the first point of the PCoA did not induce any neurological symptoms. The information from this super-selective BTO helped us to perform precise endovascular obliteration. The aneurysm was successfully obliterated, and the diplopia almost disappeared in a few months. Super-selective BTO of the PCoA might be a useful method for preventing ischemic complications due to occlusion of invisible perforators.

  18. Perioperative Internal Iliac Artery Balloon Occlusion, In the Setting of Placenta Accreta and Its Variants: The Role of the Interventional Radiologist.

    Science.gov (United States)

    Petrov, David A; Karlberg, Benjamin; Singh, Kamalpreet; Hartman, Matthew; Mittal, Pardeep K

    2017-11-10

    Placenta accreta and its variants (increta and percreta) are conditions of abnormal placentation that are encountered with increasing frequency. The spectrum of placenta accreta (including placenta increta and percreta) involves an abnormal attachment of the placental chorionic villi to the uterine myometrium. This abnormal attachment leads to increased adherence of the placenta to the uterus and abnormal placental-uterine separation at the time of delivery. Placental invasion into, or through the myometrium is associated with increased postpartum morbidity and mortality as a result of uterine hemorrhage during and following cesarean section. A multidisciplinary clinical approach to the treatment of patients with placenta accreta is recommended by the American College of Obstetricians and Gynecologists. As potential members of an interdisciplinary team, interventional radiologists can perform prophylactic internal iliac arterial balloon occlusion as an adjunctive therapy for reducing potentially life-threatening postpartum hemorrhage. The procedure involves placement of a balloon catheter into the internal iliac or common iliac arteries bilaterally prior to cesarean section. Following delivery, and prior to placental separation, the catheter balloons are inflated with a pre-determined volume of saline leading to transient occlusion of the internal iliac arteries and reduced uterine blood flow. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Extending the golden hour: Partial resuscitative endovascular balloon occlusion of the aorta in a highly lethal swine liver injury model.

    Science.gov (United States)

    Russo, Rachel M; Williams, Timothy K; Grayson, John Kevin; Lamb, Christopher M; Cannon, Jeremy W; Clement, Nathan F; Galante, Joseph M; Neff, Lucas P

    2016-03-01

    Combat-injured patients may require rapid and sustained support during transport; however, the prolonged aortic occlusion produced by conventional resuscitative endovascular balloon occlusion of the aorta (REBOA) may lead to substantial morbidity. Partial REBOA (P-REBOA) may permit longer periods of occlusion by allowing some degree of distal perfusion. However, the ability of this procedure to limit exsanguination is unclear. We evaluated the impact of P-REBOA on immediate survival and ongoing hemorrhage in a highly lethal swine liver injury model. Fifteen Yorkshire-cross swine were anesthetized, instrumented, splenectomized, and subjected to rapid 10% total blood loss followed by 30% liver amputation. Coagulopathy was created through colloid hemodilution. Randomized swine received no intervention (control), P-REBOA, or complete REBOA (C-REBOA). Central mean arterial pressure (cMAP), carotid blood flow, and blood loss were recorded. Balloons remained inflated in the P-REBOA and C-REBOA groups for 90 minutes followed by graded deflation. The study ended at 180 minutes from onset of hemorrhage or death of the animal. Survival analysis was performed, and data were analyzed using repeated-measures analysis of variance with post hoc pairwise comparisons. Mean survival times in the control, P-REBOA, and C-REBOA groups were, 25 ± 21, 86 ± 40, and 163 ± 20 minutes, respectively (p golden hour while maintaining cMAP and carotid flow at physiologic levels.

  20. Temporary balloon occlusion as therapy for uncontrollable arterial hemorrhage in multiply injured patients; Temporaere Ballonokklusion als Therapie unkontrollierbarer arterieller Blutungen bei Polytraumapatienten

    Energy Technology Data Exchange (ETDEWEB)

    Rieger, J.; Linsenmaier, U.; Rock, C.; Pfeifer, K.J. [Abt. fuer Radiologie, Klinikum Innenstadt, Ludwig-Maximilian-Univ., Muenchen (Germany); Euler, E. [Chirurgische Klinik und Poliklinik, Klinikum Innenstadt, Ludwig-Maximilian-Univ., Muenchen (Germany)

    1999-01-01

    Purpose: Presentation of temporary balloon occlusion as an interventional radiological method for managing hemorrhage in multiply injured patients with uncontrollable loss of blood. Method: Temporary, non-selective arterial occlusion by introduction of a balloon catheter contralaterally to the source of bleeding has been performed since 1992 on 7 patients with multiple injuries, hemorrhagic shock requiring reanimation, and angiographic demonstration of an arterial hemorrhage in the supply region of the internal iliac artery with complex pelvic fracture. In each case a PTA balloon catheter was introduced transfemorally, non-selectively positioned proximal to the bleeding source, and left in place for 24-48 h under manometric control. Control angiographies were performed prior to catheter removal. Results: The bleeding was stopped immediately in all 7 patients. The hemodynamic stability made transport and thus further surgical management and/or a short-term treatment in the intensive-care station possible. Control angiographies confirmed that the bleeding had stopped in all patients. Conclusions: We recommend temporary balloon occlusion as a rapid and effective method for the management of bleeding in otherwise uncontrollable traumatic hemorrhages in the supply region of the internal iliac artery. (orig.) [Deutsch] Ziel: Vorstellung der temporaeren Ballonokklusion als interventionell-radiologischer Methode zur Blutungskontrolle bei Polytraumapatienten mit unkontrollierbarem Blutverlust. Methode: Temporaerer, nicht-selektiver arterieller Gefaessverschluss mit kontralateral der Blutungsquellen eingefuehrten PTA-Ballonkathetern bei seit 1992 insgesamt 7 Patienten mit Polytrauma, reanimationspflichtigem haemorrhagischem Schock und angiographischem Nachweis einer arteriellen Blutung im Versorgungsgebiet der A. iliaca interna im Rahmen einer komplexen Beckenfraktur. Transfemoral wurde jeweils ein PTA-Ballonkatheter eingefuehrt, nicht selektiv proximal der Blutungsquelle

  1. The importance of plain radiographic signs for emergency aortography in blunt chest trauma

    International Nuclear Information System (INIS)

    Schumacher, K.A.; Trost, K.; Bargon, G.

    1983-01-01

    A retrospective study of plain radiographic findings in 11 patients with traumatic rupture of the aorta was conducted, and the results compared with the incidence of numerous chest x-rays signs previously described in 294 cases of angiographically proven thoracic aorta dissection. It is concluded that positive plain radiographic signs obtained from patients with blunt chest trauma reveal high sensitivity and may thus be used as an indication for emergency aortography. However, since this procedure lacks 100% specificity even those patients with normal x-ray findings but clinically and/or anamnestically adequate thoracic trauma should be submitted to aortography. (orig.) [de

  2. Combined Use of an Occlusion Balloon Catheter and a Microcatheter for Embolization of the Unselectable Right Inferior Phrenic Artery Supplying Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Miyayama, Shiro; Matsui, Osamu; Taki, Keiichi; Minami, Tetsuya; Ito, Chiharu; Shinmura, Rieko; Takamatsu, Shigeyuki; Kobayashi, Miki; Notsumata, Kazuo

    2004-01-01

    We report the combined use of an occlusion balloon catheter and a microcatheter for transcatheter arterial embolization (TAE) of hepatocellular carcinoma (HCC) fed by the unselectable right inferior phrenic artery (IPA). In one case, HCC was fed by the reconstructed right IPA via a small branch arising from the proximate portion of the celiac artery. In another, the tumor was fed by the right IPA that had been previously embolized with coils. TAE was successfully performed through a microcatheter placed in the celiac artery immediately proximal to the occluding balloon catheter of the celiac trunk and coil embolization of the left gastric artery

  3. Successful Reversal of Chronic Incapacitating Post-TIPS Encephalopathy by Balloon Occlusion of the Stent

    Directory of Open Access Journals (Sweden)

    Daphna Fenyves

    1994-01-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS placement is a new technique allowing decompression of the portal system without the need for abdominal surgery or general anesthetic. This promising procedure appears safe, and is being evaluated in the context of life threatening uncontrollable variceal hemorrhage as well as ascites refractory to medical treatment. Following TIPS, portal flow diversion is associated with hepatic encephalopathy in up to 25% of patients. This is most often mild and treatable but may become uncontrollable, incapacitating and even life threatening in up to 3 to 5% of cases. The authors present two patients in whom such life threatening encephalopathy and stupor was reversed by transjugular balloon occlusion of the TIPS.

  4. Spiral CT aortography: an efficient technique for the diagnosis of traumatic aortic injury

    International Nuclear Information System (INIS)

    Wicky, S.; Capasso, P.; Meuli, R.; Schnyder, P.; Fischer, A.; Segesser, L. von

    1998-01-01

    The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients. (orig.)

  5. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka; Konishi, Takahiro; Uchikawa, Yoko [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan); Fukuda, Kuniaki [University of Tsukuba Hospital, Department of Gastroenterology (Japan); Minami, Manabu [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-04-15

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

  6. Low-pressure balloon angioplasty with adjuvant pharmacological therapy in patients with acute ischemic stroke caused by intracranial arterial occlusions

    International Nuclear Information System (INIS)

    Nogueira, Raul G.; Schwamm, Lee H.; Buonanno, Ferdinando S.; Koroshetz, Walter J.; Yoo, Albert J.; Rabinov, James D.; Pryor, Johnny C.; Hirsch, Joshua A.

    2008-01-01

    The use of coronary balloons in the cerebral vasculature is limited due to their poor trackability and increased risk of vessel injury. We report our experience using more compliant elastomer balloons for thrombus resistant to intraarterial (IA) pharmacological and mechanical thrombolysis in acute stroke. We retrospectively analyzed 12 consecutive patients with an occluded intracranial artery treated with angioplasty using a low-pressure elastomer balloon. Angiograms were graded according to the Thrombolysis in Cerebral Infarction (TICI) and Qureshi grading systems. Outcomes were categorized as independent (modified Rankin scale, mRS, score ≤2), dependent (mRS score 3-5), or dead (mRS score 6). Included in the study were 12 patients (mean age 66±17 years, range 31-88 years; mean baseline National Institutes of Health stroke scale score 17±3, range 12-23). The occlusion sites were: internal carotid artery (ICA) terminus (five patients, including two concomitant cervical ICA occlusions), M1 segment (two patients), and basilar artery (two patients). Pharmacological treatment included intravenous (IV) t-PA only (two patients), IA urokinase only (nine patients), both IV t-PA and IA urokinase (one patient), and IV and/or IA eptifibatide (eight patients). Mean time to treatment was 5.9±3.9 h (anterior circulation) and 11.0±7.2 h (posterior circulation). Overall recanalization rate (TICI grade 2/3) was 91.6%. Procedure-related morbidity occurred in one patient (distal posterior inferior cerebellar artery embolus). There were no symptomatic hemorrhages. Outcomes at 90 days were independent (five patients), dependent (three patients) and dead (four patients, all due to progression of stroke with withdrawal of care). Angioplasty of acutely occluded intracranial arteries with low-pressure elastomer balloons results in high recanalization rates with an acceptable degree of safety. Prior use of thrombolytics may increase the chances of recanalization, and glycoprotein IIb

  7. Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood–Brain Barrier Disruption

    International Nuclear Information System (INIS)

    Ogami, Ryo; Nakahara, Toshinori; Hamasaki, Osamu; Araki, Hayato; Kurisu, Kaoru

    2011-01-01

    Purpose: A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood–brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Methods: Nineteen patients—5 acute-phase and 14 scheduled—underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors were examined. Results: CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Conclusions: Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.

  8. Balloon occlusion retrograde transvenous obliteration of gastric varices in two-cirrhotic patients with portal vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Borhei, Peyman; Kim, Seung Kwon; Zukerman, Darryl A [Interventional Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis (United States)

    2014-02-15

    This report describes two non-cirrhotic patients with portal vein thrombosis who underwent successful balloon occlusion retrograde transvenous obliteration (BRTO) of gastric varices with a satisfactory response and no complications. One patient was a 35-year-old female with a history of Crohn's disease, status post-total abdominal colectomy, and portal vein and mesenteric vein thrombosis. The other patient was a 51-year-old female with necrotizing pancreatitis, portal vein thrombosis, and gastric varices. The BRTO procedure was a useful treatment for gastric varices in non-cirrhotic patients with portal vein thrombosis in the presence of a gastrorenal shunt.

  9. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    Science.gov (United States)

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Post-TIPS Hepatic Encephalopathy Treated by Occlusion Balloon-Assisted Retrograde Embolization of a Coexisting Spontaneous Splenorenal Shunt

    International Nuclear Information System (INIS)

    Shioyama, Yasukazu; Matsueda, Kiyoshi; Horihata, Koushi; Kimura, Masashi; Nishida, Norifumi; Kishi, Kazushi; Terada, Masaki; Sato, Morio; Yamada, Ryusaku

    1996-01-01

    A 51-year-old man with posthepatitis cirrhosis underwent a transjugular intrahepatic portosystemic shunt (TIPS) for bleeding of recurrent esophageal varices. The patient had a coexisting, spontaneous, splenorenal shunt. He subsequently developed hepatic encephalopathy, presumably due to excessive portosystemic shunting. Since medical management resulted in no significant improvement, the splenorenal shunt was embolized from the jugular vein approach via renal vein access during temporary balloon occlusion. Within a few days, the patient's hepatic encephalopathy resolved. Twelve months later the patient showed no recurrence of encephalopathy and had maintained a patent TIPS

  11. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  12. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    International Nuclear Information System (INIS)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong

    2017-01-01

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT

  13. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong [Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-06-15

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT.

  14. The future of resuscitative endovascular balloon occlusion in combat operations.

    Science.gov (United States)

    Smith, Shane A; Hilsden, R; Beckett, A; McAlister, V C

    2017-08-09

    Damage control resuscitation and early thoracotomy have been used to increase survival after severe injury in combat. There has been a renewed interest in resuscitative endovascular balloon occlusion of the aorta (REBOA) in both civilian and military medical practices. REBOA may result in visceral and limb ischaemia that could be harmful if use of REBOA is premature or prolonged. The purpose of this paper is to align our experience of combat injuries with the known capability of REBOA to suggest an implementation strategy for the use of REBOA in combat care. It may replace the resuscitative effect of thoracotomy; can provide haemostasis of non-compressible torso injuries such as the junctional and pelvic haemorrhage caused by improvised explosive devices. However, prehospital use of REBOA must be in the context of an overall surgical plan and should be restricted to deployment in the distal aorta. Although REBOA is technically easier than a thoracotomy, it requires operator training and skill to add to the beneficial effect of damage control resuscitation and surgery. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Stunning and Right Ventricular Dysfunction Is Induced by Coronary Balloon Occlusion and Rapid Pacing in Humans: Insights From Right Ventricular Conductance Catheter Studies.

    Science.gov (United States)

    Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P

    2017-06-06

    We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  16. Balloon test occlusion of the internal carotid artery with stable xenon/CT cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Erba, S.M.; Horton, J.A.; Latchaw, R.E.; Yonas, H.; Sekhar, L.; Schramm, V.; Pentheny, S.

    1988-01-01

    We describe a technique to predict preoperatively the safety of permanently occluding an internal carotid artery. The method was performed by imaging stable xenon cerebral blood flow (CBF) with the internal carotid artery both open and temporarily occluded with a nondetachable balloon on a double lumen Swan-Ganz catheter. Patients were those in whom we planned to sacrifice the internal carotid artery (those with giant or inaccessible aneurysms) or those in whom such a sacrifice was at least likely (those with skull base tumors). Patients were divided into three groups on the basis of a comparison of occluded and nonoccluded CBF values. Group-I patients had no significant change in CBF with internal carotid artery occlusion; group-II patients showed a symmetric decrease in CBF; and group-III patients had an asymmetric decrease in CBF, always greater on the occluded side. A fourth group clinically failed to tolerate even brief carotid occlusion. The internal carotid artery in one patients from group III was sacrificed at surgery: the size and shape of his postoperative infarct corresponded almost exactly to the area of asymmetrically decreased CBF on his occluded study. The data suggest that if surgery is likely to result in permanent occlusion of the internal carotid artery, then patients who are at risk for delayed neurologic injury due to a compromised cerebral blood flow should have arterial bypass grafts before such surgery is performed

  17. Localized-low attenuation of the lung on thin-section CT in experimentally induced pulmonary arterial occlusion with balloon catheter in pigs

    International Nuclear Information System (INIS)

    Lee, Hyun Ju; Goo, Jin Mo; Im, Jung Gi; Kim, Ji Hye

    2008-01-01

    To determine whether a localized low-attenuation (LLA) is induced on a thin-section CT (TSCT) during an acute pulmonary arterial occlusion in pigs. In eight pigs, 14 sites of the descending pulmonary artery were obstructed using balloon catheters. The lung TSCTs were obtained immediately after pulmonary artery obstruction (n=13), 10 min (n=10), 30 min (n=14) and 60 min (n=14) after pulmonary artery obstruction at the end of expiration. The TSCTs were also obtained after balloon-deflation at the end of expiration (n=11) and with the balloon-reinflation at inspiration (n=6). Of the 14 sites of pulmonary artery obstruction, 11 (79%) showed LLA. However, LLA progressively became fainter or disappeared on a follow-up CT in seven sites. When the balloon was deflated, 10 of the 11 sites measured showed no change in lung attenuation. After full inspiration, LLA disappeared in three of the six sites. The corresponding areas of LLA on the CT showed a statistically significant increase compared to the baseline CT immediately after inflation (ρ =0.021) and 30 minutes after inflation (ρ = 0.041), and after balloon deflation (ρ = 0.036). LLA was induced by acute pulmonary artery obstruction. However, LLA, gradually faded over the 60 minutes following obstruction. LLAs were maintained despite the restoration of pulmonary arterial flow, but disappeared as a result of a full inspiration. Thus, LLA might be caused by air trapping

  18. Giant High-Flow Type Pulmonary Arteriovenous Malformation: Coil Embolization with Flow Control by Balloon Occlusion and an Anchored Detachable Coil

    International Nuclear Information System (INIS)

    Kanematsu, Masayuki; Kondo, Hiroshi; Goshima, Satoshi; Tsuge, Yusuke; Watanabe, Haruo; Moriyama, Noriyuki

    2012-01-01

    Pulmonary arteriovenous malformations (PAVMs) are often treated by pushable fibered or non-fibered microcoils, using an anchor or scaffold technique or with an Amplatzer plug through a guiding sheath. When performing percutaneous transcatheter microcoil embolization, there is a risk of coil migration, particularly with high-flow type PAVMs. The authors report on a unique treatment in a patient with a giant high-flow PAVM whose nidus had a maximum diameter of 6 cm. A detachable coil, not detached from a delivery wire (an anchored detachable coil), was first placed in the feeding artery under flow control by balloon occlusion, and then multiple microcoils were packed proximally to the anchored detachable coil. After confirming the stability of the microcoils during a gradual deflation of the balloon, we finally released the first detachable coil. The nidus was reduced in size to 15 mm at one year postoperatively.

  19. Double-Balloon Catheter for Isolated Liver Perfusion: An Experimental Study

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Bergqvist, Lennart; Harnek, Jan

    2001-01-01

    Purpose: Further development of a previously described interventional method for isolated liver perfusion (ILP) with a new double-lumen balloon catheter, and evaluation of the side-effects of such isolation.Methods: In six pigs a double-balloon occlusion catheter was placed via the transjugular approach with its tip in the portal vein. One of the balloons was positioned in the inferior vena cava (IVC), cranial to the origin of the hepatic veins and the other balloon in the portal vein. By the transfemoral approach, a single-balloon occlusion catheter was placed in the IVC caudal to the origin of the hepatic veins. A third catheter was placed by the transfemoral route with the occlusion balloon in the proper hepatic artery. After inflation of all balloons 99 Tc m -labelled human serum albumin was recirculated through the liver. The isolation was evaluated by repeated measurement of radioactivity levels in peripheral blood. Laboratory tests of liver and pancreas function, and hemoglobin, were taken before, at the end of, and 3 days after the procedure. Blood gases were tested at the beginning and end of the procedure.Results: One pig died during the procedure due to technical failure and was excluded from the study. In the other pigs leakage from the isolated liver to the systemic circulation increased slowly, up to 9.7% (mean) during 30 min of recirculation of the perfusate through the liver. Laboratory tests were normal in all pigs except insignificant acidosis directly after the procedure and the slight elevation of s-ALAT after 3 days.Conclusions: Only minor leakage from the liver to the systemic circulation was noted during ILP performed with a new, double-balloon catheter. There were no serious side effects

  20. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  1. Dolichoectasia (fusiform aneurysm) of the vertebral artery: Radiologic diagnosis and treatment with detachable balloon in two cases

    International Nuclear Information System (INIS)

    Tan, W.S.; Wilbur, A.C.; Jafar, J.; Abejo, R.; Kumasaki, D.; Crowell, R.; Spigos, D.G.

    1987-01-01

    Two men, aged 50 and 40 years, were treated for intracranial vertebral artery dolichoectasia using angiographic transcatheter balloon occlusion of the ipsilateral vertebral artery. Radiologic balloon occlusion was selected as an alternative to surgical ligation of the vertebral artery. Both patients had clinical signs and symptoms related to compression of both the brain stem and multiple cranial nerves. Both patients underwent occlusion of the ipsilateral vertebral artery with detachable balloons positioned at the C-1 level, below the lesions but above potential collateral pathways from the thyrocervical trunk. There were no procedural complications, and each patient has shown clinical improvement during follow-up periods of 12 months and 6 months, respectively

  2. Temporary balloon occlusion of the common hepatic artery for administration of yttrium-90 resin microspheres in a patient with patent hepatoenteric collaterals.

    Science.gov (United States)

    Mahvash, Armeen; Zaer, Navid; Shaw, Colette; Chasen, Beth; Avritscher, Rony; Murthy, Ravi

    2012-02-01

    The most common serious complication of yttrium-90 ((90)Y) therapy is gastrointestinal ulceration caused by extrahepatic microsphere dispersion. The authors describe the use of a balloon catheter for temporary occlusion of the common hepatic artery to reverse hepatoenteric flow for lobar administration of resin microspheres when coil embolization of a retroportal artery was impossible. At 9 months after treatment, the patient had no gastrointestinal side effects and showed a partial response. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  3. Clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy for large impacted proximal ureteral calculi: a prospective, randomized study.

    Science.gov (United States)

    Qi, Shiyong; Li, Yanni; Liu, Xu; Zhang, Changwen; Zhang, Hongtuan; Zhang, Zhihong; Xu, Yong

    2014-09-01

    To evaluate the clinical efficacy, safety, and costs of percutaneous occlusive balloon catheter-assisted ureteroscopic lithotripsy (POBC-URSL) for large impacted proximal ureteral calculi. 156 patients with impacted proximal ureteral stones ≥1.5 cm in size were randomized to ureteroscopic lithotripsy (URSL), POBC-URSL, and percutaneous nephrolithotomy (PNL) group between May 2010 and May 2013. For URSL, the calculi were disintegrated with the assistance of anti-retropulsion devices. POBC-URSL was performed with the assistance of an 8F percutaneous occlusive balloon catheter. PNL was finished with the combination of an ultrasonic and a pneumatic lithotripter. A flexible ureteroscope and a 200 μm laser fiber were used to achieve stone-free status to a large extent for each group. Variables studied were mean operative time, auxiliary procedure, postoperative hospital stay, operation-related complications, stone clearance rate, and treatment costs. The mean lithotripsy time for POBC-URSL was shorter than URSL, but longer than PNL (42.6±8.9 minutes vs 66.7±15.3 minutes vs 28.1±6.3 minutes, p=0.014). The auxiliary procedure rate and postoperative fever rate for POBC-URSL were significantly lower than URSL and comparable to PNL (pPNL (98.1% vs 75.0% vs 96.2%, pPNL group and similar to URSL group (p=0.016, pPNL.

  4. Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Kjeldsen, Anette D.

    2008-01-01

    Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available anymore, but use of these balloons for embolization of pulmonary arteriovenous malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing the pulmonary arteriovenous malformation. No case of recanalization has been discovered, and these results seem to justify a reduced number of controls of these balloon-embolized malformations

  5. Percutaneous endovascular therapy for symptomatic chronic total occlusion of the left subclavian artery.

    Science.gov (United States)

    Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan

    2018-03-16

    Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.

  6. Modified jailed balloon technique for bifurcation lesions.

    Science.gov (United States)

    Saito, Shigeru; Shishido, Koki; Moriyama, Noriaki; Ochiai, Tomoki; Mizuno, Shingo; Yamanaka, Futoshi; Sugitatsu, Kazuya; Tobita, Kazuki; Matsumi, Junya; Tanaka, Yutaka; Murakami, Masato

    2017-12-04

    We propose a new systematic approach in bifurcation lesions, modified jailed balloon technique (M-JBT), and report the first clinical experience. Side branch occlusion brings with a serious complication and occurs in more than 7.0% of cases during bifurcation stenting. A jailed balloon (JB) is introduced into the side branch (SB), while a stent is placed in the main branch (MB) as crossing SB. The size of the JB is half of the MB stent size. While the proximal end of JB attaching to MB stent, both stent and JB are simultaneously inflated with same pressure. JB is removed and then guidewires are recrossed. Kissing balloon dilatation (KBD) and/or T and protrusion (TAP) stenting are applied as needed. Between February 2015 and February 2016, 233 patients (254 bifurcation lesions including 54 left main trunk disease) underwent percutaneous coronary intervention (PCI) using this technique. Procedure success was achieved in all cases. KBD was performed for 183 lesions and TAP stenting was employed for 31 lesions. Occlusion of SV was not observed in any of the patients. Bench test confirmed less deformity of MB stent in M-JBT compared with conventional-JBT. This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting. © 2017 Wiley Periodicals, Inc.

  7. Onyx HD-500 embolization of intracranial aneurysms: modified technique using continuous balloon inflation under conscious sedation.

    Science.gov (United States)

    Rahme, Ralph; Grande, Andrew; Jimenez, Lincoln; Abruzzo, Todd A; Ringer, Andrew J

    2014-08-01

    The conventional technique of intracranial aneurysm embolization using Onyx HD-500 (ev3 Neurovascular, Irvine, CA, USA) involves repetitive balloon inflation-deflation cycles under general anesthesia. By limiting parent artery occlusion to 5 minutes, this cyclic technique is thought to minimize cerebral ischemia. However, intermittent balloon deflation may lengthen procedure time and allow balloon migration, resulting in intimal injury or Onyx leakage. We report our experience using a modified technique of uninterrupted Onyx injection with continuous balloon occlusion under conscious sedation. All Onyx embolization procedures for unruptured aneurysms performed by the senior author (A.J.R.) between September 2008 and April 2010 were retrospectively reviewed. Demographic, clinical, angiographic, and procedural data were recorded. Twenty-four embolization procedures were performed in 21 patients with 23 aneurysms, including four recurrences. Twenty aneurysms (87%) involved the paraclinoid or proximal supraclinoid internal carotid artery. Size ranged from 2.5 to 24mm and neck diameter from 2 to 8mm. The modified technique was employed in 19 cases. All but one patient (94.4%) tolerated continuous balloon inflation. Complete occlusion was achieved in 20 aneurysms (83.3%) and subtotal occlusion in three (12.5%). Stable angiographic results were seen in 85%, 94%, 94%, and 100% of patients at 6, 12, 24, and 36months, respectively. There were no deaths. Permanent non-disabling neurological morbidity occurred in one patient (4.2%). Minor, transient, and/or angiographic complications were seen in three patients (12.5%), none related to the technique itself. Onyx embolization of unruptured intracranial aneurysms can be safely and effectively performed using continuous balloon inflation under conscious sedation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    Science.gov (United States)

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  9. Femoro-popliteal artery occlusions treated by percutaneous transluminal angioplasty and enclosed thrombolysis

    DEFF Research Database (Denmark)

    Tønnesen, K H; Holstein, P; Andersen, E

    1991-01-01

    dilatation of femoro-popliteal occlusions, the balloons were inflated on both sides of the lesion. The dilated segment was then isolated from the circulation. Through a sideport between the balloons 5 mg of tissue type plasminogen activator and 1000 IU of heparin were installed within the segment for 30 min...

  10. Incidentally diagnosed Takayasu arteritis on thyroid ultrasonography showing prominent collateral vessels of thyroidal arteries and common carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Se Jin; Kim, Eun Kyung [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    We report a case of middle-aged woman incidentally diagnosed with Takayasu arteritis during the ultrasonography of a thyroid gland nodule. Prominent collaterals of the thyroidal arteries and a thin common carotid artery with mural thickening and deficient intraluminal flow signals were initially depicted on the ultrasonography with color Doppler. Subsequent magnetic resonance angiography and computed tomography aortography confirmed the diagnosis with the imaging features of a bilateral long segment common carotid artery occlusion and segmental stenosis of the left subclavian artery in addition to the suggestive physical findings.

  11. German Center Subanalysis of the LEVANT 2 Global Randomized Study of the Lutonix Drug-Coated Balloon in the Treatment of Femoropopliteal Occlusive Disease.

    Science.gov (United States)

    Scheinert, Dierk; Schmidt, Andrej; Zeller, Thomas; Müller-Hülsbeck, Stefan; Sixt, Sebastian; Schröder, Henrik; Weiss, Norbert; Ketelsen, Dominik; Ricke, Jens; Steiner, Sabine; Rosenfield, Kenneth

    2016-06-01

    To report a subanalysis of the German centers enrolling patients in the prospective, global, multicenter, randomized LEVANT 2 pivotal trial (ClinicalTrials.gov identifier NCT01412541) of the Lutonix drug-coated balloon (DCB) for the treatment of femoropopliteal occlusive disease. Among the 476 patients in LEVANT 2, 126 patients (mean age 67.1±9.6 years; 79 men) were enrolled at the 8 participating German sites between August 2011 and July 2012 and were randomized 2:1 to treatment with the Lutonix DCB (n=83) vs an uncoated balloon during percutaneous transluminal angioplasty (PTA, n=43). All patients had intermittent claudication or rest pain (Rutherford categories 2-4). Average lesion length was 58 mm and average treated length was 100 mm. Severe calcification was present in 11% of lesions, and 23% were total occlusions. The efficacy outcome was primary patency at 12 months, and the safety outcome was 12-month freedom from a composite of perioperative death, index limb-related death, amputation (below or above the ankle), and index limb revascularization. Secondary endpoints included target lesion revascularization (TLR), major adverse events, and functional outcomes. Demographic, clinical, and lesion characteristics were matched between Lutonix DCB and PTA groups, as were the final percent diameter stenosis (19%) and procedure success (91%). By Kaplan-Meier analysis, the 12-month primary patency rate was 80% vs 58% (p=0.015) and the composite safety endpoint rate was 94% vs 72% (p=0.001), respectively. Freedom from TLR was higher for DCBs (96%) vs PTA (82%, p=0.012). Major adverse events were similar for both groups. The benefit favoring DCB over PTA was observed in German men and women. Compared to the non-German LEVANT 2 cohort, there was a shorter time between insertion and inflation of treatment balloons (21.8 vs 39.5 seconds, pGerman cohort. Balloons were inflated to higher pressures (9.0 vs 7.7 atm, pGerman cohort had a higher baseline stenosis, final

  12. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H. [Robert Janker Klinik, Bonn (Germany); Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany); Miloslavski, E.; Lowens, S.; Reinartz, J. [Robert Janker Klinik, Bonn (Germany); Liebig, T.; Kuehne, D. [Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany)

    2005-03-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  13. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    International Nuclear Information System (INIS)

    Henkes, H.; Miloslavski, E.; Lowens, S.; Reinartz, J.; Liebig, T.; Kuehne, D.

    2005-01-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  14. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J. [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom); Broderick, Nigel [Nottingham University Hospitals, Radiology Department, Nottingham (United Kingdom); Gabra, Hany O.; Elliott, Martin J. [Great Ormond Street Hospital for Children, Department of Cardiothoracic Surgery, London (United Kingdom)

    2010-05-15

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  15. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    International Nuclear Information System (INIS)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J.; Broderick, Nigel; Gabra, Hany O.; Elliott, Martin J.

    2010-01-01

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  16. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom); Broderick, Nigel [Nottingham University Hospitals, Radiology Department, Nottingham (United Kingdom); Gabra, Hany O; Elliott, Martin J [Great Ormond Street Hospital for Children, Department of Cardiothoracic Surgery, London (United Kingdom)

    2010-05-15

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  17. Defining degree of aortic occlusion for partial-REBOA: A computed tomography study on large animals.

    Science.gov (United States)

    Reva, Viktor A; Matsumura, Yosuke; Samokhvalov, Igor M; Pochtarnik, Alexander A; Zheleznyak, Igor S; Mikhailovskaya, Ekaterina M; Morrison, Jonathan J

    2018-04-20

    Partial resuscitative endovascular balloon occlusion of the aorta (P-REBOA) is a modified REBOA technique designed to help ameliorate ischemia-reperfusion injury. The balloon is partially deflated, allowing a proportion of aortic flow distal to the balloon. The aim of this study is to use an ovine model of haemorrhagic shock to correlate the degree of occlusion to several hemodynamic indices. Six sheep weighing 35-46 kg underwent a controlled venous haemorrhage inside a CT scanner until the systolic arterial pressure (AP) dropped to fashion (proximal: r 2  = 0.85, p trend (r 2  = 0.90, p < 0.001). The relationship between percentage occlusion and IBP was sigmoid. MAP values became significantly different at 40-49% occlusion and more (p < 0.01). Furthermore, a drop in the distal pulse pressure from 7.0 (5.5-16.5) to 2.0 (1.5-5.0) mmHg was observed at 80% occlusion. All animals had femoral pulse pressure <5 mmHg at 80% of occlusion and more, which also coincided with the observed loss of pulsatility of the femoral wave-form. Serial CT angiography at an ovine model of haemorrhagic shock demonstrates a correlation between the femoral MAP, F/C pressure gradient and degree of zone I P-REBOA during the staged partial aortic occlusion. These parameters should be considered potential parameters to define the degree of P-REBOA during animal research and clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Electrophysiological and Histological Evaluation of Acute Efficacy and Safety of Balloon Occlusive Ablation at Superior Vena Cava-Right Atrial Junction

    Directory of Open Access Journals (Sweden)

    Kazushi Tanaka, MD

    2007-01-01

    Full Text Available We evaluated efficacy and safety of occlusive radiofrequency catheter ablation (o-RFA using our thermal balloon catheter (TBC at superior vena cava (SVC-right atrial (RA junction (SVCJ compared to that of RFA with a standard-tip catheter. Methods: To electrically isolate (SVCI SVC from RA in 10 pigs (group 1, the initial o-RFA at a balloon surface temperature of 53.9 ± 3.0°C for 3–5 min (13.56 MHz was achieved at the SVCJ completely obstructed with an inflated balloon. If unsuccessful, subsequent o-RFA was repeated in a ࣘ5°C increments until reaching either SVCI or sinus arrest. Before and after each o-RFA, stimulation protocol from the RA was performed. Additionally, in 5 different pigs (group 2, RFA at 55°C (ࣘ50 W for 1 min with a 4 mm-tip catheter was achieved at multiple sites along the SVCJ. Finally, the neighboring tissues of the SVCJ were histologically investigated. Results: In group 1, successful SVCI could be easily accomplished at the final temperature of 57.2 ± 2.4°C; however, in 3 pigs, a new atrial tachycardia was induced after o-RFA at <55°C and in 2 pigs sinus arrest occurred during o-RFA at 60°C. Histologically, transmural and circumferential contraction band necrosis was mainly confirmed around the SVCJ without damage to collateral tissue. In group 2, coagulation necrosis occupied almost all the ablative lesions, leading to severe degeneration of collateral tissue. Conclusion: O-RFA at the SVCJ may be more feasible and safer than RFA.

  19. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    Science.gov (United States)

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  20. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  1. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  2. Long-term Luminal Renarrowing After Successful Elective Coronary Angioplasty of Total Occlusions : A Quantitative Angiographic Analysis

    NARCIS (Netherlands)

    A.G. Violaris (Andonis); R. Melkert (Rein); P.W.J.C. Serruys (Patrick)

    1995-01-01

    textabstractBackground The long-term angiographic outcome after successful dilatation of coronary occlusions remains unclear. The objective of this study was to examine long-term restenosis after successful balloon dilatation of coronary occlusions at a predetermined time interval with quantitative

  3. Feasibility and efficacy of balloon-based neuroprotection during carotid artery stenting in a single-center setting.

    Science.gov (United States)

    Schlüter, Michael; Tübler, Thilo; Mathey, Detlef G; Schofer, Joachim

    2002-09-04

    We sought to prospectively assess the feasibility and in-hospital efficacy of the PercuSurge GuardWire temporary balloon-occlusive system for neuroprotection during carotid angioplasty and stenting (CAS).Carotid angioplasty and stenting harbors a risk of distal embolization. Cerebral protection devices are currently under clinical investigation.Ninety-six consecutive patients with carotid bifurcation disease underwent a total of 102 CAS procedures with the intention to use the GuardWire for neuroprotection. GuardWire deployment was achieved in 99 procedures performed in 93 patients (97%). Device failure (n = 3) and severe neurologic responses to balloon occlusion of the targeted carotid artery (n = 2) accounted for five additional procedures that were essentially concluded without neuroprotection, for a total of 94 procedures completed as intended in 88 patients (92% procedural feasibility rate). Carotid angioplasty and stenting was performed successfully in 94 patients (100 procedures). There were no in-hospital deaths; but three patients (3.1%) sustained strokes, and two patients experienced transient ischemic attacks, for a total periprocedural complication rate of 5.2%. One major stroke occurred with the GuardWire in place, whereas two minor strokes were observed in patients in whom the device could not be deployed. Thus, successful neuroprotected CAS without major neurologic events was achieved in 87 patients (91%). The GuardWire temporary balloon-occlusive system is feasible as an adjunct to CAS in the majority of patients. It is associated with a 3.1% rate of major periprocedural neurologic complications. Adverse neurologic reactions to balloon occlusion may prohibit effective use of the system in about 2% of patients.

  4. Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

    Energy Technology Data Exchange (ETDEWEB)

    Hörer, Tal M., E-mail: tal.horer@orebroll.se [Örebro University, Department of Cardiothoracic and Vascular Surgery, Örebro University Hospital (Sweden); Hebron, Dan [Hillel Yaffe Medical Center, Department of Radiology (Israel); Swaid, Forat [Bnai-Zion Medical Center, Department of General Surgery (Israel); Korin, Alexander [Hillel Yaffe Medical Center, Trauma Unit (Israel); Galili, Offer [Hillel Yaffe Medical Center, Department of Vascular Surgery (Israel); Alfici, Ricardo [Hillel Yaffe Medical Center, Surgical Division (Israel); Kessel, Boris [Hillel Yaffe Medical Center, Trauma Unit (Israel)

    2016-02-15

    PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach.

  5. Aorta Balloon Occlusion in Trauma: Three Cases Demonstrating Multidisciplinary Approach Already on Patient’s Arrival to the Emergency Room

    International Nuclear Information System (INIS)

    Hörer, Tal M.; Hebron, Dan; Swaid, Forat; Korin, Alexander; Galili, Offer; Alfici, Ricardo; Kessel, Boris

    2016-01-01

    PurposeTo describe the usage of aortic balloon occlusion (ABO), based on a multidisciplinary approach in severe trauma patients, emphasizing the role of the interventional radiologist in primary trauma care.MethodsWe briefly discuss the relevant literature, the technical aspects of ABO in trauma, and a multidisciplinary approach to the bleeding trauma patient. We describe three severely injured trauma patients for whom ABO was part of initial trauma management.ResultsThree severely injured multi-trauma patients were treated by ABO as a bridge to surgery and embolization. The procedures were performed by an interventional radiologist in the early stages of trauma management.ConclusionsThe interventional radiologist and the multidisciplinary team approach can be activated already on severe trauma patient arrival. ABO usage and other endovascular methods are becoming more widely spread, and can be used early in trauma management, without delay, thus justifying the early activation of this multidisciplinary approach

  6. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    International Nuclear Information System (INIS)

    Murdoch, Dale; McAulay, Laura; Walters, Darren L.

    2014-01-01

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy

  7. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, Dale, E-mail: dale_murdoch@health.qld.gov.au [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia); McAulay, Laura [The Prince Charles Hospital, Brisbane (Australia); Walters, Darren L. [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia)

    2014-11-15

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy.

  8. Segmentally enclosed thrombolysis in percutaneous transluminal angioplasty for femoropopliteal occlusions

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Nielsen, J D

    1991-01-01

    Segmentally enclosed thrombolysis (SET) was performed immediately following 34 percutaneous transluminal angioplasties (PTAs) for femoropopliteal occlusions. The dilated segment was sealed off with a double balloon catheter, and recombinant tissue plasminogen activator (rt-PA) 1 mg/ml and heparin...

  9. Selective occlusion of a carotid sinus cavernous fistula after transsphenoidal hypophysectomy

    International Nuclear Information System (INIS)

    Lins, E.; Dietrich, U.; Wappenschmidt, J.

    1987-01-01

    A case of carotid cavernous sinus fistula following transsphenoidal hypophysectomy is reported. A selective occlusion of the fistula with patency of the carotid artery was achieved by means of a detachable balloon catheter. (orig.) [de

  10. Resuscitative Endovascular Balloon Occlusion of the Aorta and Resuscitative Thoracotomy in Select Patients with Hemorrhagic Shock: Early Results from the American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery Registry.

    Science.gov (United States)

    Brenner, Megan; Inaba, Kenji; Aiolfi, Alberto; DuBose, Joseph; Fabian, Timothy; Bee, Tiffany; Holcomb, John B; Moore, Laura; Skarupa, David; Scalea, Thomas M

    2018-05-01

    Aortic occlusion is a potentially valuable tool for early resuscitation in patients nearing extremis or in arrest from severe hemorrhage. The American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery registry identified trauma patients without penetrating thoracic injury undergoing aortic occlusion at the level of the descending thoracic aorta (resuscitative thoracotomy [RT] or zone 1 resuscitative endovascular balloon occlusion of the aorta [REBOA]) in the emergency department (ED). Survival outcomes relative to the timing of CPR need and admission hemodynamic status were examined. Two hundred and eighty-five patients were included: 81.8% were males, with injury due to penetrating mechanisms in 41.4%; median age was 35.0 years (interquartile range 29 years) and median Injury Severity Score was 34.0 (interquartile range 18). Resuscitative thoracotomy was used in 71%, and zone 1 REBOA in 29%. Overall survival beyond the ED was 50% (RT 44%, REBOA 63%; p = 0.004) and survival to discharge was 5% (RT 2.5%, REBOA 9.6%; p = 0.023). Discharge Glasgow Coma Scale score was 15 in 85% of survivors. Prehospital CPR was required in 60% of patients with a survival beyond the ED of 37% and survival to discharge of 3% (all p > 0.05). Patients who did not require any CPR before had a survival beyond the ED of 70% (RT 48%, REBOA 93%; p American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Data and methods to estimate fetal dose from fluoroscopically guided prophylactic hypogastric artery balloon occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Solomou, G.; Stratakis, J. [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Heraklion, Crete 71003 (Greece); Perisinakis, K.; Tsetis, D.; Damilakis, J., E-mail: john.damilakis@med.uoc.gr [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Heraklion, Crete 71003, Greece and Department of Medical Physics, University Hospital of Heraklion, P.O. Box 1352, Heraklion, Crete 71110 (Greece)

    2016-06-15

    Purpose: To provide data for estimation of fetal radiation dose (D{sub F}) from prophylactic hypogastric artery balloon occlusion (HABO) procedures. Methods: The Monte-Carlo-N-particle (MCNP) transport code and mathematical phantoms representing a pregnant patient at the ninth month of gestation were employed. PA, RAO 20° and LAO 20° fluoroscopy projections of left and right internal iliac arteries were simulated. Projection-specific normalized fetal dose (NFD) data were produced for various beam qualities. The effects of projection angle, x-ray field location relative to the fetus, field size, maternal body size, and fetal size on NFD were investigated. Presented NFD values were compared to corresponding values derived using a physical anthropomorphic phantom simulating pregnancy at the third trimester and thermoluminescence dosimeters. Results: NFD did not considerably vary when projection angle was altered by ±5°, whereas it was found to markedly depend on tube voltage, filtration, x-ray field location and size, and maternal body size. Differences in NFD < 7.5% were observed for naturally expected variations in fetal size. A difference of less than 13.5% was observed between NFD values estimated by MCNP and direct measurements. Conclusions: Data and methods provided allow for reliable estimation of radiation burden to the fetus from HABO.

  12. Treatment of Angio-Seal-Related Femoral Artery Occlusion Using Directional Atherectomy-Primary Results and Midterm Follow-Up.

    Science.gov (United States)

    Babaev, Anvar; Gokhale, Rohit; Zavlunova, Susanna; Attubato, Michael

    2016-11-01

    We describe a novel approach for the endovascular treatment of femoral artery occlusion as a result of Angio-Seal closure device deployment. Angio-Seal is the most commonly used vascular closure device following percutaneous coronary and peripheral catheterizations worldwide. A rare complication of Angio-Seal deployment is an occlusion of the femoral artery leading to limb ischemia requiring revascularization. Given its unique ability to cut both atherosclerotic plaque and the Angio-Seal anchor with a collagen plug at operator-directed planes, TurboHawk/HawkOne atherectomy device can be a fast and effective approach to treat Angio-Seal-associated femoral artery occlusions. We studied 13 consecutive patients who developed Angio-Seal-associated femoral artery occlusions that occurred from 3 hours to several weeks after catheterization. These patients were successfully treated with TurboHawk/HawkOne directional atherectomy followed by balloon angioplasty with no complications. During a mean follow-up period of 20.4 ± 17.3 months, 12 patients remained claudication free with no evidence of obstructive arterial disease of the treated segment on imaging studies. One patient developed restenosis that was treated with repeat atherectomy and balloon angioplasty following which he was asymptomatic at follow-up. The use of directional atherectomy followed by balloon angioplasty is a quick, safe, and effective endovascular approach to treating Angio-Seal-associated femoral artery occlusions. It is associated with an excellent success rate, no complications, and good midterm outcomes.

  13. Embolization of carotid-cavernous fistula using a silicone balloon and a tracker-catheter system

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Cho, Kil Ho; Park, Bok Hwan

    1992-01-01

    With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in case of small fistula, pseudo aneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitation, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients (silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing

  14. Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten

    Energy Technology Data Exchange (ETDEWEB)

    Landwehr, P; Lackner, K [Wuerzburg Univ. (Germany, F.R.). Inst. fuer Roentgendiagnostik; Goetz, R [Wuerzburg Univ. (Germany, F.R.). Abt. fuer Nephrologie

    1990-09-01

    On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

  15. Cerebral Perfusion Long Term after Therapeutic Occlusion of the Internal Carotid Artery in Patients Who Tolerated Angiographic Balloon Test Occlusion

    NARCIS (Netherlands)

    Gevers, S.; Heijtel, D.; Ferns, S. P.; van Ooij, P.; van Rooij, W. J.; van Osch, M. J.; van den Berg, R.; Nederveen, A. J.; Majoie, C. B.

    2012-01-01

    BACKGROUND AND PURPOSE: Therapeutic carotid occlusion is an established technique for treatment of large and giant aneurysms of the (CA, in patients with synchronous venous filling on angiography during BTO. Concern remains that hemodynamic alterations after permanent occlusion will predispose the

  16. The Effect of Infrarenal Aortic Balloon Occlusion on Weaning from Supraceliac Aortic Balloon Occlusion in a Porcine Model (Sus scrofa) of Hemorrhagic Shock

    Science.gov (United States)

    2017-06-15

    all animals , and continued for six hours. Half of the animals were randomly assigned to Zone-3 REBOA for an additional 45 minutes following Zone-1...concentration or resuscitation requirements.Conclusion: In an animal model of hemorrhagic shock and Zone-1 REBOA, subsequent Zone-3 aortic occlusion did not add

  17. Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Ming; Chu, Sung-Yu; Hsu, Ming-Yi [Chang Gung University, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Taoyuan (China); Liao, Ying-Lan [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Tsai, Hui-Yu [Chang Gung University, Department of Medical Imaging and Radiological Sciences, College of Medicine, Taoyuan (China); Chang Gung University, Healthy Aging Research Center, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China)

    2014-02-15

    To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDI{sub vol}), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. The low-tube-voltage protocol showed 23-31 % higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48 % reduction in CTDI{sub vol} and an 80 % increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. (orig.)

  18. Aggressive nonsurgical management of acute coronary artery occlusions developing immediately after percutaneous transluminal coronary angioplasty (PTCA)

    International Nuclear Information System (INIS)

    Levin, D.C.; Meyerovitz, M.; Boxt, L.; Taus, R.; Ganz, P.; Friedman, P.; Selwyn, A.

    1986-01-01

    In 368 consecutive percutaneous transluminal coronary angiography (PTCA) procedures, acute occlusion of the dilated artery developed within the first hour after the procedure in 24 cases (6.5%). Four patients underwent emergency bypass surgery. In 17 of the remaining 20 patients, repeat balloon dilation was immediately attempted, and was successful in 11 instances (65%). Five of the six cases in which repeat balloon dilation was not successful responded well to surgical or medical therapy. The author conclude that acute occlusions of dilated coronary arteries shortly after PTCA do not automatically necessitate emergency bypass. Approximately two thirds of such cases can be managed by repeat dilation, converting a potential complication into a successful outcome

  19. Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.

    Science.gov (United States)

    Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y

    1994-09-01

    One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.

  20. A complex dissected chronic occlusion: targeted balloon dilatation of false lumen to access true lumen, combined localized subintimal tracking and reentry, parallel wire, contralateral injection and a useful antegrade lumen re-entry technique

    Directory of Open Access Journals (Sweden)

    James W. Tam

    2012-02-01

    Full Text Available Chronic total occlusion (CTO angioplasty is one of the most challenging procedures remaining for the interventional operator. Recanalizing CTOs can improve exercise capacity, symptoms, left ventricular function and possibly reduce mortality. Multiple strategies such as escalating wire, parallel wire, seesaw, contralateral injection, subintimal tracking and re-entry (STAR, retrograde wire techniques (controlled antegrade retrograde subintimal tracking, CART, reverse CART, confluent balloon, rendezvous in coronary, and other techniques have all been described. Selection of the most appropriate approach is based on assessment of vessel course, length of occluded segment, presence of bridging collaterals, presence of bifurcating side branches at the occlusion site, and other variables. Today, with significant operator expertise and the use of available techniques, the literature reports a 50-95% success rate for recanalizing CTOs.

  1. Laser Recanalization of Central Venous Occlusion to Salvage a Threatened Arteriovenous Fistula.

    Science.gov (United States)

    Rambhia, Sagar; Janko, Matthew; Hacker, Robert I

    2018-07-01

    Central venous occlusion is conventionally managed with balloon angioplasty, stent extension, or sharp recanalization. Here, we describe recanalization of a chronically occluded innominate vein using excimer laser after conventional techniques were unsuccessful. Patient clinical improvement and fistula patency have been sustained 2 years postintervention. This technique may provide new hemodialysis access options for patients who would not otherwise be candidates for hemodialysis access on the ipsilateral side of a central venous occlusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Anesthetic management of cesarean section in cases of placenta accreta, with versus without abdominal aortic balloon occlusion: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Chu, Qinjun; Shen, Dan; He, Long; Wang, Hongwei; Zhao, Xianlan; Chen, Zhimin; Wang, Yanli; Zhang, Wei

    2017-05-26

    Placenta accreta (PA), a severe complication during delivery, is closely linked with massive hemorrhage which could endanger the lives of both mother and baby. Moreover, the incidence of PA has increased dramatically with the increasing rate of cesarean deliveries in the past few decades. Therefore, studies evaluating the effects of different perioperative managements based on different modalities in the treatment of PA are necessary. Among the numerous treatment measures, prophylactic abdominal aortic balloon occlusion (AABO) in combination with cesarean section for PA seems to be more advantageous than others. However, up to now, all studies on AABO were almost retrospective. Current evidence is insufficient to recommend for or against routinely using the AABO technology for control intraoperative hemorrhage in patients with PA. Thus, we hope to carry out a prospective, randomized controlled trial (RCT) study to confirm the effectiveness of the AABO technology in patients with PA. This trial is an investigator-initiated, prospective RCT that will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. A total of 170 parturients with PA undergoing cesarean section will be randomized to receive either AABO in combination with cesarean section or the traditional hysterectomy following cesarean section. The primary outcome is estimated blood loss. The most important secondary outcome is the occurrence of cesarean hysterectomy during delivery; others include blood transfusion volume, operating time, neonate's Apgar scores (collected at 1, 5 and 10 min), length of stay in intensive care unit, total hospital stay, and balloon occlusion-relative data. This prospective trial will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. It may provide strong evidence

  3. Resuscitative endovascular balloon occlusion of the aorta with a low profile, wire free device: A game changer?

    Directory of Open Access Journals (Sweden)

    James N. Bogert

    2017-02-01

    Full Text Available A 24 year old male arrived to our hospital after a motor cycle crash with evidence of a traumatic brain injury and in hemorrhagic shock not responsive to volume administration. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA was performed in a timely fashion using a new, low profile, wire free device. This lead to rapid reversal of hypotension while his bleeding source was sought and controlled.Recently, REBOA has emerged as an adjunct in the hypotensive trauma patient with noncompressible torso hemorrhage. As first described, this procedure makes use of commonly available vascular surgery and endovascular products requiring large introducer sheaths (12–14 French and long guidewires. Concerns regarding this technique center around the safety and feasibility of using such equipment in the emergency setting outside an angiography suite. This has likely limited widespread adoption of this technique. To address these concerns, newer products designed to be placed through a smaller sheath (7 French and without the use of guidewires have been developed. Here we report on our first clinical use of such a device that we believe represents a significant advance in the care of the trauma patient. Keywords: REBOA, Resuscitation, Hemorrhage, Endovascular

  4. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Sabharwal, Tarun, E-mail: tarun_sabharwal@yahoo.co.uk [Guy' s and St. Thomas' Hospitals, NHS Foundation Trust, Department of Radiology (United Kingdom)

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  5. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    International Nuclear Information System (INIS)

    Krokidis, Miltiadis; Spiliopoulos, Stavros; Katsanos, Konstantinos; Sabharwal, Tarun

    2013-01-01

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  6. Cool excimer laser-assisted angioplasty (CELA) and tibial balloon angioplasty (TBA) in management of infragenicular arterial occlusion in critical lower limb ischemia (CLI).

    Science.gov (United States)

    Sultan, Sherif; Tawfick, Wael; Hynes, Niamh

    2013-04-01

    We aim to compare cool excimer laser-assisted angioplasty (CELA) versus tibial balloon angioplasty (TBA) in patients with critical limb ischemia (CLI) with tibial artery occlusive disease. The primary end point is sustained clinical improvement (SCI) and amputation-free survival (AFS). The secondary end points are binary restenosis, target extremity revascularization (TER), and cost-effectiveness. From June 2005 to October 2010, 1506 patients were referred with peripheral vascular disease and 572 with CLI. A total of 80 patients underwent 89 endovascular revascularizations (EVRs) for tibial occlusions, 47 using TBA and 42 using CELA. All patients were Rutherford category 4 to 6. Three-year SCI was enhanced with CELA (81%) compared to TBA (63.8%; P = .013). Three-year AFS significantly improved with CELA (95.2%) versus TBA (89.4%; P = .0165). Three-year freedom from TER was significantly improved with CELA (92.9%) versus 78.7% TBA (P = .026). Three-year freedom from MACE was comparable in both the groups (P = .455). Patients with CELA had significantly improved quality time without symptoms of disease or toxicity of treatment (Q-TWiST) at 3 years (10.5 months; P = .048) with incremental cost of €2073.19 per quality-adjusted life year gained. Tibial EVR provides exceptional outcome in CLI. The CELA has superior SCI, AFS, and freedom from TER, with improved Q-TWiST and cost-effectiveness.

  7. Significance of preoperative cerebral blood flow measurements in endovascular occlusion of the internal carotid and middle cerebral arteries

    International Nuclear Information System (INIS)

    Laurent, A.; Weitzner, I.; Luft, A.; Merland, J.J.

    1988-01-01

    Cerebral blood flow (CBF) measurements during 12 endovascular balloon occlusions (ten internal carotid and two middle cerebral arteries) with good clinical and angiographic tolerance were done with repeated boluses of Xe-133 injected directly into the ipsi- and contralateral carotid systems, during the occlusion and repeated measurements with detectors on both sides (before occlusion and 5-30 minutes after occlusion). In two cases of unchanged and four of increased CBF, one reversible deficit was probably due to an embolus. In six cases of decreased CBF, two deficits occurred, characterized by a greater than 25% decrease. It seems to represent a good predictive value for intolerance to occlusion

  8. Complex Coronary Interventions with the Novel Mozec™ CTO Balloon: The MOZART Registry.

    Science.gov (United States)

    Lupi, Alessandro; Rognoni, Andrea; Schaffer, Alon; Secco, Gioel G; Bongo, Angelo S

    2015-01-01

    Mozec™ CTO is a novel semicompliant rapid-exchange PTCA balloon catheter with specific features dedicated to treat complex coronary lesions like chronic total occlusions (CTOs). However, no data have been reported about the performance of this device in an all-comers population with complex coronary lesions. We evaluated the safety and success rate of Mozec™ CTO balloon in 41 consecutive patients with chronic stable angina and complex coronary lesions (15 severe calcified coronary stenoses, 15 bifurcation lesions with planned two-stent intervention, and 11 CTOs). Safety was assessed reporting the balloon burst rate after inflation exceeding the rated burst pressure (RBP) according to the manufacturer's reference table. Success was defined as the possibility to advance the device further the target lesion. The Mozec™ CTO balloon showed an excellent performance with a 93.3% success in crossing tight and severely calcified lesions (14/15 pts), a 93.3% success in engaging jailed side branches after stent deployment across bifurcations (14/15 pts), and a 90.9% success in crossing CTO lesions (10/11 pts). The burst rate at RBP of the Mozec™ CTO balloon was 6.7% (1/15 balloons) in the tight and severely calcified lesions, 6.7% (1/15 balloons) when dilating jailed vessels, and 9.1% (1/11 balloons) in CTOs. The novel Mozec™ CTO balloon dilatation catheter showed promising results when employed to treat complex lesions in an all-comers population. Further studies should clarify if this kind of balloon might reduce the need of more costly devices like over-the-wire balloons and microcatheters for complex lesions treatment.

  9. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, F.A.B.; Spithoven, J.H.; Zeebregts, C.J.A.; Scharn, D.M.; Reijnen, M.M.

    2015-01-01

    PURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  10. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, Frederike A. B.; Spithoven, J. Hans; Zeebregts, Clark J.; Scharn, Dirk M.; Reijnen, Michel M. P. J.

    Purpose: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. Materials and Methods: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  11. Balloon-occluded Retrograde Transvenous Obliteration (BRTO): Technique and Intraprocedural Imaging

    Science.gov (United States)

    Sabri, Saher S.; Saad, Wael E. A.

    2011-01-01

    Balloon-occluded retrograde transvenous obliteration (BRTO) is an endovascular technique used as a therapeutic adjunct or alternative to transjugular intrahepatic shunts (TIPS) in the management of gastric varices. Occlusion balloons are strategically placed to modulate flow within the gastrorenal or gastrocaval shunt to allow stagnation of the sclerosant material within the gastric varix. The approach and complexity of the procedure depends on the anatomic classification of inflow and outflow veins of the varix. Ethanolamine oleate has been described as the main sclerosant used in this procedure. Recently, foam sclerosants have gained popularity as alternative embolization agents, which provide the advantage of better variceal wall contact and potentially less dose of sclerosant. PMID:22942548

  12. An Intestinal Occlusion Device for Prevention of Small Bowel Distention During Transgastric Natural Orifice Transluminal Endoscopic Surgery

    OpenAIRE

    Tomasko, Jonathan M.; Mathew, Abraham; Moyer, Matthew T.; Haluck, Randy S.; Pauli, Eric M.

    2013-01-01

    Background and Objectives: Bowel distention from luminal gas insufflation reduces the peritoneal operative domain during natural orifice transluminal endoscopic surgery (NOTES) procedures, increases the risk for iatrogenic injury, and leads to postoperative patient discomfort. Methods: A prototype duodenal occlusion device was placed in the duodenum before NOTES in 28 female pigs. The occlusion balloon was inflated and left in place during the procedure, and small bowel distension was subject...

  13. Power Doppler Imaging in Acute Renal Vein Occlusion and Recanalization: a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, So-Young; Kim, In-One; Kim, Young-Il; Lee, Kyoung Ho; Lee, Min Woo; Youn, Byung Jae; Kim, Woo Sun; Yeon, Kyung Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-04-15

    Objective : To evaluate the dynamic changes of the power Doppler (PD) in acute renal vein occlusion and recanalization in a canine model. Materials and Methods : We performed a PD of the kidney during graded renal vein occlusion and recanalization induced by balloon inflation and deflation in nine dogs. The PD images were transferred to a personal computer, and the PD signals were quantified. Result : We observed the temporal change of the PD signal during renal vein occlusion and recanalization, with a decrease in the PD signal during occlusion and an increase during recanalization. The mean PD signal decreased gradually as the renal vein was occluded, and conversely increased gradually with sequential relief of occlusion. The sequential change of the mean value of the PD signal was statistically significant. Conclusion : The PD can detect a change in renal blood flow during acute renal vein occlusion and recanalization in a canine model. The PD may be used as a helpful tool for the early detection of acute renal vein thrombosis and the monitoring of renal perfusion.

  14. Power Doppler Imaging in Acute Renal Vein Occlusion and Recanalization: a Canine Model

    International Nuclear Information System (INIS)

    Yoo, So-Young; Kim, In-One; Kim, Young-Il; Lee, Kyoung Ho; Lee, Min Woo; Youn, Byung Jae; Kim, Woo Sun; Yeon, Kyung Mo

    2008-01-01

    Objective : To evaluate the dynamic changes of the power Doppler (PD) in acute renal vein occlusion and recanalization in a canine model. Materials and Methods : We performed a PD of the kidney during graded renal vein occlusion and recanalization induced by balloon inflation and deflation in nine dogs. The PD images were transferred to a personal computer, and the PD signals were quantified. Result : We observed the temporal change of the PD signal during renal vein occlusion and recanalization, with a decrease in the PD signal during occlusion and an increase during recanalization. The mean PD signal decreased gradually as the renal vein was occluded, and conversely increased gradually with sequential relief of occlusion. The sequential change of the mean value of the PD signal was statistically significant. Conclusion : The PD can detect a change in renal blood flow during acute renal vein occlusion and recanalization in a canine model. The PD may be used as a helpful tool for the early detection of acute renal vein thrombosis and the monitoring of renal perfusion

  15. Revascularization Techniques for Acute Basilar Artery Occlusion : Technical Considerations and Outcome in the Setting of Severe Posterior Circulation Steno-Occlusive Disease.

    Science.gov (United States)

    Siebert, Eberhard; Bohner, Georg; Zweynert, Sarah; Maus, Volker; Mpotsaris, Anastasios; Liebig, Thomas; Kabbasch, Christoph

    2018-04-12

    To describe the clinical and radiological characteristics, frequency, technical aspects and outcome of endovascular treatment of acute basilar artery occlusion (ABO) in the setting of vertebrobasilar steno-occlusive disease. Retrospective analysis of databases of two universitary stroke centers including all consecutive patients from January 2013 until May 2017 undergoing thrombectomy for a) acute stroke due to basilar artery occlusion and either significant basilar artery stenosis or vertebral artery stenosis/occlusion as well as b) presumed embolic basilar artery occlusions. Demographics, stroke characteristics, time metrics, recanalization results and outcome were recorded. Interventional strategies were evaluated concerning the thrombectomy technique, additional angioplasty, type of approach with respect to lesion pattern (ipsilateral to steno-occlusive VA lesion: dirty road or contralateral: clean road) and sequence of actions. Out of 157 patients treated for ABO 38 (24.2%) had associated significant vertebrobasilar steno-occlusive lesions. An underlying significant basilar artery stenosis was present in 23.7% and additionally significant steno-occlusive vertebral lesions were present in 81.5%. Thrombectomy was performed with primary aspiration in 15.8% and with stent-retrievers in 84.2%. Successful revascularization (TICI 2b-3) was achieved in 86.8%. In 52.6% additional stent angioplasty was performed, in 7.9% balloon angioplasty only. The clean road approach was used in 22.5% of cases, the dirty road in 77.4%. Final modified Rankin scale (mRS) was 0-2 in 6 patients (15.8%) and 3-5 in 32 (84.2%). The in-hospital mortality was 36.8%. There were no statistically significant differences in outcome compared to presumed cases of embolisms. Endovascular treatment of ABO with underlying significant vertebrobasilar steno-occlusive lesions is effective and reasonably safe. Specific procedural strategies apply depending on individual patient pathology and anatomy

  16. REBOA at Role 2 Afloat: resuscitative endovascular balloon occlusion of the aorta as a bridge to damage control surgery in the military maritime setting.

    Science.gov (United States)

    Rees, Paul; Waller, B; Buckley, A M; Doran, C; Bland, S; Scott, T; Matthews, J

    2018-05-01

    Role 2 Afloat provides a damage control resuscitation and surgery facility in support of maritime, littoral and aviation operations. Resuscitative endovascular balloon occlusion of the aorta (REBOA) offers a rapid, effective solution to exsanguinating haemorrhage from pelvic and non-compressible torso haemorrhage. It should be considered when the patient presents in a peri-arrest state, if surgery is likely to be delayed, or where the single operating table is occupied by another case. This paper will outline the data in support of endovascular haemorrhage control, describe the technique and explore how REBOA could be delivered using equipment currently available in the Royal Navy Role 2 Afloat equipment module. Also discussed are potential future directions in endovascular resuscitation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Vertebral Arteriovenous Fistula Presenting as Cervical Myelopathy: A Rapid Recovery with Balloon Embolization

    International Nuclear Information System (INIS)

    Modi, Manish; Bapuraj, J. Rajiv; Lal, Anupam; Prabhakar, S.; Khandelwal, N.

    2010-01-01

    A 24-year-old male presented with progressive cervical myelopathy of 2 months' duration. Magnetic resonance imaging of the cervical spine and angiography revealed a large arteriovenous fistula arising from the left vertebral artery. The present case highlights the clinical features and dramatic recovery following endovascular balloon occlusion of a giant cervical arteriovenous fistula.

  18. Evaluation of the fetal dose during prophylactic placement of internal iliac artery balloon occlusion catheters in placenta accreta

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sik [Dept. of Radiology, Gachon University Gil hospital, Incheon (Korea, Republic of); Ahn, Sung Min [Dept. of Radiological Science, Gachon University, Incheon (Korea, Republic of)

    2016-09-15

    Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38∼8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49∼18.27 mGy.

  19. Thrombus aspiration catheter is a Dottering balloon

    Directory of Open Access Journals (Sweden)

    D. Sheshagiri Rao

    2016-07-01

    Full Text Available Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate?

  20. Dual Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varix Draining into the Left Adrenal Vein and Left Inferior Phrenic Vein

    International Nuclear Information System (INIS)

    Nishida, Norifumi; Ninoi, Teruhisa; Kitayama, Toshiaki; Yamamoto, Akira; Sakai, Yukimasa; Sato, Kimihiko; Hamuro, Masao; Nakamura, Kenji; Inoue, Yuichi; Yamada, Ryusaku

    2004-01-01

    A 66-year-old woman with a gastric varix, draining into a dilated left adrenal vein and a left inferior phrenic vein, was treated with dual balloon-occluded retrograde transvenous obliteration (B-RTO). Under balloon occlusion of the left adrenal vein and the left inferior phrenic vein, retrograde injection of a sclerosant (5% ethanolamine oleate) into the gastric varix was performed. Two weeks later, disappearance of flow in the gastric varix was confirmed on endoscopic ultrasound examination

  1. Symptomatic portal vein occlusion: treated by interventional radiological techniques

    International Nuclear Information System (INIS)

    Wang Maoqiang; Gu Xiaofang; Guan Jun; Wang Zhongpu; Liu Fengyong; Wang Zhiqiang

    2004-01-01

    Objective: To evaluate the efficacy and safety of the interventional radiological techniques for management of symptomatic portal vein (PV) occlusion. Methods: Nine patients with PV trunk occlusion were treated using interventional procedures. Four patients presented with abdominal pain, distention, and malabsorption; five presented with portal hypertension and repeated bleeding from esophagogastric varices. The etiologic factors were identified in all 9 patients, including post-transplantation of the liver in 2, hepatocellular carcinoma (HCC) associated with PV tumor thrombus in 3, post abdominal operative state in 1, and PV thrombosis in 3 cases. The portal access was established via a percutaneous transhepatic route in 4, and via a transjugular intrahepatic portosystemic shunt ( TIPS) approach in 5 patients. The interventional procedures included stent placement in 4, balloon angioplasty in 6, and catheter directed pharmacologic and mechanical thrombolysis in 7 patients. Results: The technical success was achieved in all cases. No complications related to the procedure occurred. Portal flow was reestablished in all patients after the procedures. Clinical improvement was seen in 3 patients with symptomatic PV thrombosis, characterized by progressive reduction of abdominal pain, distention, and diarrhea. Follow-up time ranged from 4 to 36 months. One patient with HCC died of multiple organs metastases at 11 months after the treatment . One patient died of intraabdominal sepsis and multiple organs failure 12 days after the procedure even though the antegrade flow was re-established in the main trunk of the PV. Patency of the PV trunk was confirmed by follow-up color Doppler ultrasound scan in the rest 7 patients, without recurrence of variceal bleeding or PV thrombus. Conclusions: Interventional minimally invasive procedures, including balloon angioplasty, stent placement, catheter directed local pharmacologic and mechanical thrombolysis, are safe and effective in

  2. Balloon-occluded retrograde transvenous obliteration of gastric varix draining via the left inferior phrenic vein into the left hepatic vein

    International Nuclear Information System (INIS)

    Ibukuro, Kenji; Mori, Koichi; Tsukiyama, Toshitaka; Inoue, Yoshihiro; Iwamoto, Yukako; Tagawa, Kazumi

    1999-01-01

    We encountered a patient with gastric varix draining not via the usual left suprarenal vein but via the left inferior phrenic vein joining the left hepatic vein. Transfemoral balloon-occluded retrograde transvenous obliteration (BRTO) of the varix was performed under balloon occlusion of the left inferior phrenic vein via the left hepatic vein and retrograde injection of the sclerosing agent (5% of ethanolamine oleate) into the gastric varix. Disappearance of the gastric varix was confirmed on endoscopic examination 2 months later.

  3. Edge Stenosis After Covered Stenting for Long Superficial Femoral Artery Occlusive Disease: Risk Factor Analysis and Prevention With Drug-Coated Balloon Angioplasty.

    Science.gov (United States)

    Lin, Ting-Chao; Huang, Chun-Yang; Chen, Po-Lin; Lee, Chiu-Yang; Shih, Chun-Che; Chen, I-Ming

    2018-06-01

    To report a retrospective analysis of risk factors for edge restenosis after Viabahn stent-graft treatment of superficial femoral artery (SFA) occlusive disease and determine any protective effect of drug-coated balloons (DCBs) used at the time of stent-graft implantation. Between October 2011 and July 2016, 110 patients (mean age 73.3±7.6 years; 78 men) were treated with the Viabahn stent-graft for long SFA occlusions. Thirty-eight (34.5%) patients had DCB reinforcement at the distal edge of the stent-graft. For analysis, the population was divided into groups of no edge stenosis patients (n=88; mean lesion length 22.4±4.2 cm) and edge stenosis patients (n=22; mean lesion length 23.5±5.7 cm). The clinical outcomes, ankle-brachial indices, computed tomography angiography findings, and patency were compared at a minimum of 12 months. Logistic regression analysis was employed to determine risk factors for edge stenosis; the results are presented as the odds ratio (OR) and 95% confidence interval. No differences in clinical or procedural characteristics were identified except the higher incidence of diabetes (p=0.008) and greater need for retrograde access (p=0.033) in the edge stenosis group. DCB reinforcement reduced the incidence of edge stenosis (p=0.021) and target lesion revascularization (TLR; p=0.010) and resulted in a significantly higher 1-year primary patency rate (92.1% vs 76.4%, p=0.042). However, multivariate analysis revealed only poor distal runoff (OR 0.31, 95% CI 0.11 to 0.83, p=0.020) as a predictor of edge stenosis. The risk of edge stenosis after Viabahn implantation was higher in patients with poor distal runoff. DCB reinforcement over the distal edge reduced edge stenosis, decreased 1-year TLR, and improved 1-year primary patency.

  4. Double-Balloon-Assisted n-Butyl-2-Cyanoacrylate Embolization of Intrahepatic Arterioportal Shunt Prior to Chemoembolization of Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp; Shibata, Eisuke; Ohtomo, Kuni [University of Tokyo, Department of Radiology, Graduate School of Medicine (Japan)

    2016-10-15

    A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for other than intrahepatic arterioportal shunt.

  5. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    Science.gov (United States)

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  6. Successful penetration and bougie dilatation with Brockenbrough needle for severely calcified occlusion in superficial femoral artery.

    Science.gov (United States)

    Makita, Toshio; Suzuki, Kenji; Takizawa, Kaname; Ootomo, Tatsushi; Inoue, Naoto; Meguro, Taiichirou

    2014-04-01

    A 75-year-old hemodialysis patient with right critical limb ischemia received endovascular therapy for a chronic total occlusion (CTO) in a diffusely calcified superficial femoral artery (SFA). During a retrograde approach, a Brockenbrough needle (BN) was able to penetrate the calcified hard plaque formed in the middle segment of the CTO. Moreover, bougie dilatation with the BN allowed balloon crossing and stent deployment, even after failure to pass a 2.0-mm monorail balloon across the plaque. These results suggest that the BN offers a new therapeutic option in the penetration and modification of severely calcified CTO in SFA.

  7. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  8. Subintimal Recanalization of Long Superficial Femoral Artery Occlusions Through the Retrograde Popliteal Approach

    International Nuclear Information System (INIS)

    Yilmaz, Saim; Sindel, Timur; Ceken, Kagan; Alimoglu, Emel; Lueleci, Ersin

    2001-01-01

    Purpose: To investigate the value of the retrograde popliteal artery approach for the percutaneous intentional extraluminal recanalization (PIER) of long superficial femoral artery (SFA) occlusions.Methods: During a period of 17 months, PIER through ultrasound-guided retrograde popliteal artery puncture was performed for 39 long SFA occlusions in 37 patients. In six patients, six additional iliac artery stenoses were also treated via the popliteal approach.Results: The procedure was technically successful in 32 (82%) of 39 SFA occlusions; in 29, lesions were treated with balloon angioplasty alone, and in three, stents were also used. Cumulative patency rate was 66% at 6 months, 62% at 1 year, and 59% at 18 months. Additional iliac artery stenoses were successfully treated in the same session. Complications included two minor hematomas and two SFA ruptures, which required no treatment.Conclusion: PIER through retrograde popliteal puncture is a safe and effective method in the treatment of long femoropopliteal occlusions, with a high technical success, low complication rate and a reasonable short-term patency rate. The technique offers an alternative in cases where standard PIER is unsuccessful or contraindicated

  9. Endovascular management of inferior vena cava filter thrombotic occlusion.

    Science.gov (United States)

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  10. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  11. Clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting

    Directory of Open Access Journals (Sweden)

    Xiang-yu CAO

    2016-12-01

    Full Text Available Objective To explore the clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting to predict the reflux of perforator veins after operation. Methods A total of 93 patients (including 51 with cerebral venous sinus stenosis and intracranial hypertension and 42 with intractable pulsatile tinnitus caused by cerebral venous sinus stenosis who were treated by stent implantation were analyzed retrospectively. Among those patients, the diameter of transverse and sigmoid sinuses of 63 cases were measured based on angiography, and stent was selected according to the measurement result. The other 30 cases were given angiography on ipsilateral carotid artery or vertebral artery when the balloon was dilated in the venous sinus to confirm the reflux of perforator veins. If the venous reflux decreased in the angiography, stent with diameter 1-2 mm less than that of venous sinus could be selected.  Results The success rate of stenting was 100% (93/93. In 63 cases, 45 cases were planted 9 mm × 40 mm stents, 15 were planted 8 mm × 40 mm stents, 3 were planted 7 mm × 40 mm stents. The average diameter of stents was (8.67 ± 0.68 mm. There were 11 cases (17.46% with slow perforator venous reflux after operation. In the other 30 cases, 3 cases were planted 8 mm × 40 mm stents, 11 were planted 7 mm × 40 mm stents, and 16 were planted 6 mm × 40 mm stents. The average diameter of stents was (7.57 ± 0.67 mm. There was only one case (3.33% with slow perforator venous reflux after operation. The difference of stent diameter between 2 groups was statistically significant (t = 15.632, P = 0.001. The occurrence rate of perforator vein occlusion after operation between 2 groups was significantly different (adjusted χ 2 = 60.065, P = 0.001.  Conclusions Perforator vein occlusion after cerebral venous sinus stenting is common complication. Balloon dilatation angiography could predict the possibility of perforator vein

  12. Clinical observations on the effect of carotid artery occlusion on cerebral blood flow mapped by xenon computed tomography and its correlation with carotid artery back pressure

    International Nuclear Information System (INIS)

    Steed, D.L.; Webster, M.W.; DeVries, E.J.; Jungreis, C.A.; Horton, J.A.; Sehkar, L.; Yonas, H.

    1990-01-01

    Xenon computed tomographic cerebral blood flow mapping was correlated with internal carotid artery stump pressures and clinical neurologic assessment during temporary internal carotid artery occlusion. One hundred fourteen patients with skull base tumors or intracranial aneurysms potentially requiring carotid resection or ligation underwent angiography, xenon CT cerebral blood flow mapping, and internal carotid artery blood pressure monitoring. The internal carotid artery was then temporarily occluded with a balloon catheter, stump pressure was measured through the catheter, and the xenon CT cerebral blood flow mapping was repeated. Adequate xenon CT cerebral blood flow was defined as greater than 30 cc/100 gm/min. All patients had normal xenon CT cerebral blood flow before internal carotid artery occlusion. During internal carotid artery occlusion, xenon CT cerebral blood flow was found to be normal (group I, 40 patients), globally reduced but still within the normal range (group II, 50 patients), or low in the distribution of the ipsilateral middle cerebral artery (group III, 13 patients). With balloon occlusion, an immediate neurologic deficit developed in 11 patients (9%) requiring deflation of the balloon preceding xenon CT cerebral blood flow measurement (group IV). In group I internal carotid artery blood pressure was 128 mm Hg. (range 85 to 171 mm Hg) with stump pressure 86 mm Hg (range 46 to 125 mm Hg). In group II internal carotid artery blood pressure was 130 mm Hg. (range 78 to 199 mm Hg), with stump pressure 86 mm Hg (range 31 to 150 mm Hg)

  13. An attempt of thallium-201 myocardial perfusion imaging during transient coronary arterial occlusion by PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Katahira, Toshio

    1989-01-01

    To evaluate the myocardial perfusion during transient coronary occlusion, we attempted to obtain the myocardial scintigraphy during percutaneous transluminal coronary angioplasty (PTCA). Tl-201 was injected at the last inflation of angioplastic balloon and occlusion was kept on for 60 sec. Planar images or SPECT were obtained immediately after PTCA. With this protocol, myocardial perfusion defects were observed during PTCA and fully redistributed 3 hours after Tl injection. Extent of ischemic lesions were almost same as that observed during exercise in two cases without collateral vessels. In a case with well visualized collateral vessels, perfusion defect was smaller in PTCA images than that in exercise stressed images. We conclude that intravenous injection of Tl-201 during PTCA is useful to assess the alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedure. (author)

  14. Diffusion-weighted magnetic resonance imaging in carotid angioplasty and stenting with balloon embolic protection devices

    International Nuclear Information System (INIS)

    Asakura, Fumio; Kawaguchi, Kenji; Sakaida, Hiroshi; Toma, Naoki; Matsushima, Satoshi; Kuraishi, Keita; Tanemura, Hiroshi; Miura, Yoichi; Taki, Waro; Maeda, Masayuki

    2006-01-01

    We compared the results of two procedures to protect against distal embolism caused by embolic debris from carotid angioplasty with stent deployment (CAS) using diffusion-weighted magnetic resonance imaging (MRI). The study group comprised 39 men and 3 women (42 and 3 CAS procedures, respectively) with severe carotid stenosis (average age 70.0±6.6 years). During 20 CAS procedures the internal carotid artery was protected with a single balloon. A PercuSurge GuardWire was used for temporary occlusion. During 25 CAS procedures the internal and external carotid arteries were simultaneously temporarily occluded with a PercuSurge GuardWire and a Sentry balloon catheter, respectively. Diffusion-weighted MRI was performed 1 to 3 days after CAS. Data from 26 patients undergoing conventional angiography for diagnosis of cerebral ischemic disease, cerebral aneurysm or brain tumors were included as controls. Diffusion-weighted MRI after conventional diagnostic angiography showed ischemic spots in 3 of the 26 controls (11.5%). Ischemic spots were observed during 11 of 20 CAS procedures with the internal carotid artery protected with a single balloon (55.0%), and were observed during 9 of 25 CAS procedures with both the internal and external carotid arteries protected (36.0%). This difference was significant (P=0.0068). Ischemic lesions appeared not only ipsilateral to the carotid stenosis but also in the contralateral carotid artery (31.9%) and vertebrobasilar territory (25.3%). Better protection was obtained with simultaneous double occlusion of both the internal and external carotid artery than with single protection of the internal carotid artery during CAS. (orig.)

  15. Balloon Blocking Technique (BBT) for Superselective Catheterization of Inaccessible Arteries with Conventional and Modified Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp, E-mail: mori-h33@xa2.so-net.ne.jp [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp [Kyoto Prefectural University of Medicine, Department of Radiology, North Medical Center (Japan); Ito, Takaaki, E-mail: takaaki@koto.kpu-m.ac.jp [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Hayashi, Natsuko, E-mail: hayashin@koto.kpu-m.ac.jp [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science (Japan); Sato, Osamu, E-mail: osamu-sato@kyoto1-jrc.org [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan)

    2016-06-15

    PurposeThe purpose of the study was to retrospectively evaluate the efficacy and safety of the balloon blocking technique (BBT).Materials and MethodsThe BBT was performed in six patients (all males, mean 73.5 years) in whom superselective catheterization for transcatheter arterial embolization by the conventional microcatheter techniques had failed due to anatomical difficulty, including targeted arteries originating steeply or hooked from parent arteries. All BBT procedures were performed using Seldinger’s transfemoral method. Occlusive balloons were deployed and inflated at the distal side of the target artery branching site in the parent artery via transfemoral access. A microcatheter was delivered from a 5-F catheter via another femoral access and was advanced over the microguidewire into the target artery, under balloon blockage of advancement of the microguidewire into non-target branches. After the balloon catheter was deflated and withdrawn, optimal interventions were performed through the microcatheter.ResultsAfter success of accessing the targeted artery by BBT, optimal interventions were accomplished in all patients with no complications other than vasovagal hypotension, which responded to nominal therapy.ConclusionThe BBT may be useful in superselective catheterization of inaccessible arteries due to anatomical difficulties.

  16. Interventional Radiological Treatment of Perihepatic Vascular Stenosis or Occlusion in Pediatric Patients After Liver Transplantation

    International Nuclear Information System (INIS)

    Uller, Wibke; Knoppke, Birgit; Schreyer, Andreas G.; Heiss, Peter; Schlitt, Hans J.; Melter, Michael; Stroszczynski, Christian; Zorger, Niels; Wohlgemuth, Walter A.

    2013-01-01

    Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysis (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown

  17. Indication, procedure, and choice of the embolisation material in transcatheteral vascular occlusion

    International Nuclear Information System (INIS)

    Vogel, H.; Niemeier, J.; Hamburg Univ.

    1985-01-01

    If it is planned to effect transcatheteral occlusion of vessels, it must be examined whether the relevant vessel should be occluded permanently or temporarily and whether the occlusion should be located centrally in the vascular trunk or in a major twig, or peripherally in the region of the capillaries, arterioles and small vessels. Temporary occlusion with fibrospum is usually sufficient for treating a haemorrhage. Ethibloc or Bucrylate can be employed to shut off an organ and to achieve partial organ necrosis. Arteriovenous connections with a large vascular lumen can be occluded by means of metal particles. Peripherally occluding substances should not be used for embolisations in the gastrointestinal range because of the risk of local necrosis and possible dangerous infection resulting therefrom. To the present day hardly any indications have been found for the use of absolute alcohol. Bucrylate has the drawback, compared against Ethibloc, that the catheter may adhere to the vascular wall. Vessels with a low flow rate should be occluded either by means of balloon catheter or a coaxial catheter system because of the risk of reflux. (orig.) [de

  18. Enterprise stent in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Ji, Yong; Ding, Xuan; Zang, Yizheng; Wang, Chengwei

    2017-11-01

    To investigate the safety and effectiveness of recanalization in non-acute occlusion of intracranial internal carotid arteries using the flexible Enterprise self-expanding stent. From June 2014 to June 2016, 12 consecutive patients with non-acute occlusion of intracranial internal carotid arteries received endovascular recanalization with Enterprise stenting. All patients received medication for anti-platelet aggregation therapy before and after the operation. The perioperative complications and recanalization efficacy were evaluated with the modified Rankin scoring system and digital subtraction angiography (DSA) follow-up, respectively. Endovascular recanalization was successfully performed in 10 out of 12 patients with Enterprise stenting. Stent implantation following balloon dilatation failed in one patient because the lumen diameter was too small. Another recanalization failed because the guide wire could not pass through the occlusion. No perioperative mortality was observed. One case of acute thrombosis and one case of intraoperative carotid spasm occurred, but these were resolved with thrombolytic therapy by microcatheter exposure treatment and antispasmodic medications, respectively. DSA follow-up in seven patients revealed no re-occlusion. One stroke event occurred in the 10 patients who completed the follow-up. A meaningful improvement in the modified Rankin score during follow-up was suggested by Wilcoxon signed-rank test results. The Enterprise stent was shown to be safe and efficient in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion. However, the long-term outcomes need to be further investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The modified pulse-spray method using Urokinase in subacute and chronic thrombotic arterial occlusion

    International Nuclear Information System (INIS)

    Kim, Youn Kil; Hahn, Seong Tae; Baek, Jee Hee; Kim, Choon Yul; Shinn, Kyung Sub

    1996-01-01

    To evaluate the effectiveness and safety of the modified pulse-spray method using Urokinase(UK) in subacute and chronic thrombotic arterial occlusion. Modified pulse-spray methods using UK were performed in seven patients with subacute (1 week-1month) to chronic (1month-5years) occlusive symptoms such as limb pain, claudication and impotence. Angiographic examination revealed thrombotic occlusion of the aorta, common iliac arteries, brachial arterio-venous hemodialysis graft and femoro-popliteal bypass graft. The patients underwent thrombolysis using modified pulse-spray and additional constant infusion of UK. In the presence of underlying stenosis or organized clots, balloon angioplasty or stent placement was performed. Complete lysis was obtained in five of seven patients. For initial lysis, the mean dose of UK was 420,000 units, and the mean modified pulse-spray time was 50 minutes. Mean total dose of UK and mean total time for complete lysis were 800,000 units and 161 minutes, respectively. Thrombolysis of the femoro-popliteal bypass graft failed due to severe occlusion of the distal anastomosis. Partial lysis was achieved in one patient with aorto-illac occlusion, but further thrombolysis was stopped due to bleeding at the puncture site. The modified pulse-spray method using UK is effective in treating subacute and chronic arterial thrombotic occlusion. It augments the speed, safety and efficacy of thrombolysis. When underlying stenosis or organized clots remain after thrombolysis, ballon angioplasty or stent placement would be helpful

  20. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    International Nuclear Information System (INIS)

    Zhang, Qingqiao; Huang, Qianxin; Shen, Bin; Sun, Jingmin; Wang, Xiaolong; Liu, Hongtao

    2015-01-01

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or two hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion

  1. Percutaneous mechanical atherectomy for treatment of peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Buecker, A.; Minko, P.; Massmann, A.; Katoh, M.

    2010-01-01

    Peripheral arterial occlusive disease (PAOD) is still an extremely important politico-economic disease. Diverse treatment procedures exist but the pillars of therapy are changes in lifestyle, such as nicotine abstinence and walking exercise as well as drug therapy. Further therapy options are considered after conventional procedures have been exhausted. These further options consist of improvement of the blood supply by surgical or minimally invasive procedures. The latter therapy options include balloon dilatation and stenting as the most widely used techniques. More recent techniques also used are cryoplasty, laser angioplasty, drug-coated stents or balloons as well as brachytherapy or atherectomy, whereby this list makes no claims to completeness. The multitude of different treatment methods emphatically underlines the fact that no resounding success can be achieved with one single method. The long-term results of both balloon dilatation and stenting techniques show a need for improvement, which elicited the search for additional methods for the treatment of PAOD. Atherectomy represents such an alternative method for treatment of PAOD. Basically, the term atherectomy means the removal of atheroma tissue. For percutaneous atherectomy, in contrast to surgical procedures, it is not necessary to create surgically access to the vessel but accomplishes the atherectomy by means of dedicated systems via a minimally invasive access. There are two basic forms of mechanical atherectomy: directional and rotational systems. (orig.) [de

  2. Novel experience of laser-assisted 'inside-out' central venous access in a patient with bilateral subclavian vein occlusion requiring pacemaker implantation.

    Science.gov (United States)

    Aye, Thandar; Phan, Thanh Trung; Muir, Douglas Findlay; Linker, Nicholas John; Hartley, Richard; Turley, Andrew John

    2017-10-01

    This new laser facilitated 'inside-out' technique was used for transvenous pacemaker insertion in a pacemaker-dependent patient with bilateral subclavian occlusion and a failed epicardial system who is not suitable for a transfemoral approach. Procedure was undertaken under general anaesthesia with venous access obtained from right femoral vein and left axillary vein. 7F multipurpose catheter was used to enter proximal edge of the occluded segment of subclavian vein via femoral approach, which then supported stiff angioplasty wires and microcatheters to tunnel into the body of occlusion. When encountered with impenetrable resistance, 1.4 mm Excimer laser helped delivery of a Pilot 200 wire, which then progressed towards the distal edge of occlusion. Serial balloon dilatations allowed wire tracked into subintimal plane, advanced towards left clavicle using knuckle wire technique, which was then externalized with blunt dissection from infraclavicular pocket area. It was later changed to Amplatz superstiff wire exiting from both ends to form a rail, which ultimately allowed passage of pacing leads after serial balloon dilatation from clavicular end. Our hybrid 'inside-out' technique permitted transvenous pacemaker insertion without complication and this is, to our knowledge, the first case using laser in this context. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  3. Clinical impact and risk stratification of balloon angioplasty for femoropopliteal disease in nitinol stenting era: Retrospective multicenter study using propensity score matching analysis

    Directory of Open Access Journals (Sweden)

    Taketsugu Tsuchiya

    2016-07-01

    Full Text Available Objective: Nitinol stenting could bring the better outcome in endovascular therapy for femoropopliteal disease. However, it might be expected that recent marked advances in both device technology and operator technique had led to improved efficacy of balloon angioplasty even in this segment. The aims of this study were to evaluate the clinical impact of balloon angioplasty for femoropopliteal disease and make risk stratification clear by propensity score matching analysis. Methods: Based on the multicenter retrospective data, 2758 patients (balloon angioplasty: 729 patients and nitinol stenting: 2029 patients, those who underwent endovascular therapy for femoropopliteal disease, were analyzed. Results: The propensity score matching procedure extracted a total of 572 cases per group, and the primary patency rate of balloon angioplasty and nitinol stenting groups after matching was significantly the same (77.2% vs 82.7% at 1 year; 62.2% vs 64.3% at 3 years; 47.8% vs 54.3% at 5 years. In multivariate Cox hazard regression analysis, significant predictors for primary patency were diabetes mellitus, regular dialysis, cilostazol use, chronic total occlusion, and intra-vascular ultra-sonography use. The strategy of balloon angioplasty was not evaluated as a significant predictor for the primary patency. After risk stratification using five items (diabetes mellitus, regular dialysis, no use of intra-vascular ultra-sonography, chronic total occlusion, and no use of cilostazol: the DDICC score, the estimated primary patency rates of each group (low, DDICC score 0–2; moderate, DDICC score 3; high risk, DDICC score 4–5 were 88.6%, 78.3%, and 63.5% at 1 year; 75.2%, 60.7%, and 39.8% at 3 years; and 66.0%, 47.1%, and 26.3% at 5 years (p < 0.0001. The primary patency rate of balloon angioplasty and nitinol stenting groups was significantly the same in each risk stratification. Conclusion: This study suggests that balloon angioplasty does

  4. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  5. [Complete denture occlusion considered from occlusal contacts during mastication].

    Science.gov (United States)

    Suzuki, Tetsuya

    2004-12-01

    Few reports describe the functional superiority of full balanced occlusion to that of lingualized occlusion. Recently, a bilateral balanced scheme has been much more generally applied than a unilateral balanced scheme in lingualized occlusion as well as in full balanced occlusion. Occlusal contacts on the non-chewing side occur earlier than on the chewing side;in the order of second molar, first molar, and then premolars. The contact on the balancing side contributes to the prevention of denture dislocation and guidance from eccentric positions to the centric occlusal position during mastication. Therefore, bilateral balanced occlusion was shown to be effective for denture stability during mastication with complete dentures. Today's typical edentulous patients have greater mean age than in the past, and thus are seen with severe alveolar bone resorption, thin mucosa and sometimes abnormalities of the maxillomandibular relation. Their occlusal positions are often unstable and changeable after insertion of complete dentures. Because lingualized occlusion allows for easier accommodation and correction, lingualized occlusion is more suitable for such cases than full balanced occlusion, which requires a strict occlusal relationship. In light of the standard Japanese diet, there is some doubt about why lingualized occlusion might be suitable for Japanese edentulous patients in terms of the sense of mastication. A method of evaluating the sense of mastication needs to be established.

  6. Energy from solar balloons

    Energy Technology Data Exchange (ETDEWEB)

    Grena, Roberto [C. R. Casaccia, via Anguillarese 301, 00123 Roma (Italy)

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  7. [Relationship between Occlusal Discomfort Syndrome and Occlusal Threshold].

    Science.gov (United States)

    Munakata, Motohiro; Ono, Yumie; Hayama, Rika; Kataoka, Kanako; Ikuta, Ryuhei; Tamaki, Katsushi

    2016-03-01

    Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.

  8. Technical note: subclavian artery misplacement of a 12F Shaldon catheter: percutaneous repair with a local closure device under temporary balloon tamponade; Technische Mitteilung: Entfernung eines fehlplatzierten 12F Shaldon Katheters aus der A. subclavia und Abdichtung mittels Verschlusssystem bei temporaerer Ballonblockade

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Katoh, M.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Fussen, R. [Anaesthesiologische Klinik, Medizinisches Zentrum Kreis Aachen GmbH (Germany)

    2006-06-15

    A case of subsequent percutaneous repair using a local closure device with a collagen block (VasoSeal {sup registered}) and temporary balloon tamponade after inadvertent subclavian artery misplacement of a 12F Shaldon catheter is reported. Balloon occlusion safely prevented displacement of collagen into the vascular lumen by occluding the 12F entry site. Furthermore, collagen-induced coagulation was facilitated. (orig.)

  9. Reliable porcine coronary model of chronic total occlusion using copper wire stents and bioabsorbable levo-polylactic acid polymer.

    Science.gov (United States)

    Sim, Doo Sun; Jeong, Myung Ho; Cha, Kyoung Rae; Park, Suk Ho; Park, Jong Oh; Shin, Young Min; Shin, Heungsoo; Hong, Young Joon; Ahn, Youngkeun; Schwartz, Robert S; Kang, Jung Chaee

    2012-12-01

    Chronic total occlusion (CTO) remains a challenge in interventional cardiology. We investigated the feasibility and reliability of copper wire stents and levo-polylactic acid (l-PLA) as a means of CTO induction in a porcine model. In one group of 20 swine, copper stents were crimped on a 3.0mm angioplasty balloon and inserted into the mid-left anterior descending coronary artery (LAD). In the other group of 20 swine, l-PLA was wrapped on a guidewire and pushed into the distal LAD with a 3.0mm balloon catheter to induce embolization. Of 20 swine which underwent copper stent implantation, 13 died of stent thrombosis. In the remaining 7 swine, total or near total occlusion with collateral circulation was observed at 5 weeks. Of 20 swine which underwent l-PLA embolization, 4 died of ventricular fibrillation during or shortly after the procedure. Serial histopathologic studies showed complete absorption of the polymer with replacement by fibrotic tissue approximately 4 weeks following the polymer implantation. CTO could be reliably induced in porcine coronary arteries by copper stents and l-PLA. These models may support investigation of new percutaneous devices to facilitate CTO interventions. Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  10. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    Science.gov (United States)

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion

  11. Nursing assistance for spring coil occlusion for the treatment of intracranial giant internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Ma Yugang; Mao Yanjun; Yuan Yili; Hu Yaqin; Liu Jing; Xi Juan

    2010-01-01

    Objective: To discuss the importance of balloon occlusion test before interventional treatment of the intracranial giant internal carotid artery aneurysms and to sum up the nursing experience in assisting the procedure. Methods: Proper perioperative nursing measures were carried out for 12 patients, who suffered from intracranial giant internal carotid artery aneurysm and underwent spring coil occlusion treatment. Nursing measures included mental care, observation of the vital signs, prevention of the complications, etc. Results: Neither death nor exacerbation of the condition occurred in all the 12 patients. The patients were discharged from the hospital with a mean hospitalization of nine days. During a follow-up period ranged from 4 months to one year, seven patients had no disagreeable feeling, one patient complained of discomfort but no abnormality was found on follow-up DSA, and disappearance of the aneurysm was observed in 4 patients. Conclusion: The monitoring of the vital signs, the prevention of the complications and the standard nursing care are the key points for ensuring a successful operation in treating intracranial giant internal carotid artery aneurysms with spring coil occlusion. (authors)

  12. Occlusal stability.

    Science.gov (United States)

    Wiens, Jonathan P; Priebe, Jennifer W

    2014-01-01

    Occlusion is the foundation for clinical success in fixed, removable, and implant prosthodontic treatment. Understanding those principles is critical when restoring a patient's occlusion. Many philosophies, devices, and theories of occlusion have evolved based on anecdotal clinical observations and applied geometric perceptions. The literature has reported these classic and contemporary occlusal concepts. As evidence-based dentistry emerged, it championed scrutiny of previously held beliefs, resulting in the abandonment of many pragmatic, yet beneficial occlusal procedures. The impetus toward scientific discovery, whereby factual information might be universally applied in dental education and clinical practice, has renewed interest in occlusal studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Percutaneous balloon dilatation for transplant ureteral strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Chul [Chungnam National University School of Medicine, Taechun (Korea, Republic of); Banner, Marc P [University of Pennsylvania School of Medicine, Philadelphia (United States)

    1993-09-15

    We report 10 kidney allografted patients treated for 11 ureteral strictures with standard endourlogic balloon catheter dilatation and internal stenting between August 1979 and December 1991. They have been followed until 2 to 140 months (mean 42). We compared and analyzed the 6 successful strictures (54%) and 5 unsuccessful strictures. There was no statistically significant difference of demographic, clinical and radiologic interventional techniques between two groups. But there was slightly higher success rate in abruptly narrowed shorter fibrotic strictures in ureteroneocystomy sites than smoothly taped longer ones in other sites of the ureter. Longterm stenting by the transplantation team with cystoscopic removal of internal ureteral stents by urologists resulted in 3 cases of stent occlusion, encrustation or fracture. Exact early diagnosis of ureteral stricture with continued close follow up and proper radiologic interventional procedure with optimal stenting period may increase the success rate and still provide an alternative to surgery.

  14. Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward; Patel, Rahul S.; Scott Nowakowski, F.; Lookstein, Robert A.; Fischman, Aaron M. [Icahn School of Medicine at Mount Sinai, Interventional Radiology Section, Department of Radiology (United States)

    2016-06-15

    PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

  15. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  16. Percutaneous Management of Occlusive Arterial Disease Associated with Vasculitis: A Single Center Experience

    International Nuclear Information System (INIS)

    Both, M.; Jahnke, T.; Reinhold-Keller, E.; Reuter, M.; Grimm, J.; Biederer, J.; Brossmann, J.; Gross, W.L.; Heller, M.; Mueller-Huelsbeck, S.

    2003-01-01

    The purpose of this study was to evaluate the safety and effectiveness of percutaneous transluminal angioplasty for occlusive arterial disease associated with vasculitis. Eleven patients(10 women, 1 man; ages 35-82 years) with the diagnosis of vasculitis of the large vessels underwent interventional treatment during intraarterial angiography. The causes included giant cell arteritis(n = 8) and Takayasu arteritis (n = 3).Thirty-three occlusive lesions (including brachiocephalic and renalarteries, and arteries of upper and lower extremities) were treated with balloon angioplasty and/or stent placement. Follow-up included clinical examination, angiography, and color duplex ultrasound.Technical success was 100% (25/25) for stenoses and 50% (4/8) for occlusive lesions, representing all lesions combined from different anatomic locations. Dissection (n = 3) and arterial rupture with retroperitoneal hematoma (n = 1) was found in three patients. During follow-up (mean 12 months), restenoses(n = 8) and re-restenoses (n = 1)occurred in 8 vascular areas. Three of these lesions were treated with repeated PTA (n = 4). The cumulative primary clinical success rate was 67.6%, cumulative secondary success rate 74.4%, and cumulative tertiary success rate 75.9%. Interventional therapy in systemic vasculitis provides promising results in technical success rates and followup. Angioplasty may result in arterial injury, but the rate of complications is low

  17. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    International Nuclear Information System (INIS)

    Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.

    2013-01-01

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  18. Balloon sinuplasty

    OpenAIRE

    Ahmad, Zahoor

    2010-01-01

    Balloon sinuplasty is a technique in endoscopic sinus surgery that involves minimally invasive procedures to dilate the obstructed or stenosed anatomical sinus pathways. Procedure is derived from the well-recognized techinique of angioplasty. This article highlights the procedural methods with review of literature and my personal experience in balloon sinupalsty.

  19. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  20. Investigation of hot air balloon fatalities.

    Science.gov (United States)

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  1. Balloon angioplasty of infrapopliteal artery in chronic lower limb ischemia with diabetes

    International Nuclear Information System (INIS)

    Wang Jianbo; Zhao Jungong; Zhu Yueqi; Li Minghua; Cheng Yingsheng; Cheng Yongde; Wang Jue

    2008-01-01

    Objective: To evaluate the technique, successful rate and perioperative complications together with the therapy and prevention of using PTA in treating diabetic patients with infrapopliteal arterial diseases. Methods: Angiographic and clinical data of 27 patients with diabetic lower limb ischemia treated by PTA from January 2006 to May 2007 were retrospectively reviewed. Rutherf0rd-Becker categories and ankle- brachial index(ABI)were evaluated before and after the treatment. The effects were compared between different lesion types (stenosis or occlusion)and between different ways of balloon technique. The complications were also analyzed, together with the primary, discussion of the therapy and prevention. Results: 24 patients showed improvement of ischemic symptoms, and 3 cases fell in failure. The intra-procedural main complications included acute thrombosis, vascular wall perforation, distal emboli resulting from plaque falling off and dissection. There were statistically significant differences between the effects of two type lesions and between different balloon methods. Conclusions: 1. The condition of lower limb arteries should be assessed carefully before operation. 2. PTA shows safe and good clinical result and ought to be recommended in treating diabetic patients with peripheral arterial diseases, especially the lower extremity ischemia. (authors)

  2. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  3. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  4. Variations in pulmonary artery occlusion pressure to estimate changes in pleural pressure.

    Science.gov (United States)

    Bellemare, Patrick; Goldberg, Peter; Magder, Sheldon A

    2007-11-01

    A readily available assessment of changes in pleural pressure would be useful for ventilator and fluid management in critically ill patients. We examined whether changes in pulmonary artery occlusion pressure (Ppao) adequately reflect respiratory changes in pleural pressure as assessed by changes in intraesophageal balloon pressure (Peso). We studied patients who had a pulmonary catheter and esophageal balloon surrounding a nasogastric tube as part of their care (n=24). We compared changes in Ppao (dPpao) to changes in Peso (dPeso) by Bland-Altman and regression analysis. Adequacy of balloon placement was assessed by performing Mueller maneuvers and adjusting the position to achieve a ratio of dPeso to change in tracheal pressure (dPtr) of 0.85 or higher. This was achieved in only 14 of the 24 subjects. We also compared dCVP to dPeso. The dPpao during spontaneous breaths and positive pressure breaths gave a good estimate of Peso but generally underestimated dPeso (bias=2.2 +8.2 and -3.9 cmH2O for the whole group). The dCVP was not as good a predictor (bias=2.9 +10.3 and -4.6). In patients who have a pulmonary artery catheter in place dPpao gives a lower estimate of changes in pleural pressure and may be more reliable than dPeso. The dCVP is a less reliable predictor than changes in pleural pressure.

  5. Interventional therapy of atherosclerotic renal artery occlusion

    International Nuclear Information System (INIS)

    Li Jian; Xu Ke; Xiao Liang

    2009-01-01

    Objective: To investigate the effectiveness of interventional therapy for the atherosclerotic renal artery occlusion (ARAO). Methods: During the period of June 2001-Dec. 2007, 16 patients with ARAO (total of 16 occluded arteries) underwent interventional managements, including percutaneous endovascular renal artery revascularization, balloon dilatation angioplasty and stent placement. Follow-up survey was made at regular intervals. The patent condition of the renal artery was evaluated with ultrasonography and digital subtraction angiography. The blood pressure and the renal function were determined and the data were statistically analyzed in order to assess the intermediate and long-term effect of the interventional therapy. Results: Of 16 patients, technical success was achieved in 15 (93.8%) and failure occurred in one. During a follow-up period of 9 - 24 months, 3 patients died. According to the data obtained at each patient's last follow-up survey, the hypertension fell to normal in 3 (25.0%), was improved in 7 (58.3%) and showed no marked change in 2 patients (16.7%), with a clinical efficacy of 83.3% (10 / 12). The renal function was improved in 2 (16.7%), stabilized in 6 (50%) and deteriorated in 4 patients (33.3%), with an effective rate of 66.7% (8 / 12). Conclusion: For the treatment of atherosclerotic renal artery occlusion, the interventional therapy carries high successful rate and can effectively lower the blood pressure level, in addition, it can also protect the renal function in a certain degree. (authors)

  6. Patients with restored occlusions. Part III: The effect of occlusal splint therapy and occlusal adjustments on TMJ dysfunction.

    Science.gov (United States)

    Lederman, K H; Clayton, J A

    1983-07-01

    An earlier study of 50 patients with occlusions restored by fixed partial dentures indicated a high percent (68%) of TMJ dysfunction. Occlusal interferences can play a significant role in causing TMJ dysfunction. To determine the significance of occlusal interferences, occlusal splints were placed in 10 of these restored patients who had moderate to severe dysfunction. The PRI was used to detect the presence or absence of TMJ dysfunction. The PRI TMJ dysfunction scores were reduced in all 10 patients after use of the occlusal splint. Five of the patients achieved reproducible tracings (no TMJ dysfunction) during the experiment time of 7 months. The occlusion of two patients was adjusted to eliminate the need for the occlusal splint. Patients who wore the splint 24 hours a day showed a significant (0.0004 level) reduction in TMJ dysfunction. Those patients who did not wear the splint regularly or had high levels of stress had PRI scores that varied. This finding indicates that the occlusal splint is not a treatment, as its removal permits reactivation of the occlusal interference. Resolution of dysfunction did not occur until occlusal interferences were removed. The changes in PRI scores to different dysfunction categories (none, slight, moderate, and severe) for the experimental group were significant at the 0.01 level. A control group of five patients had similar pantographic tracings but no other treatment. Their PRI scores varied, but there was no significant change in PRI scores or dysfunction categories. It was concluded that occlusal interferences were active causes of TMJ dysfunction in 10 of 36 patients in a population with restored occlusions.

  7. Technique, Complication, and Long-Term Outcome for Endovascular Treatment of Iliac Artery Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri

    2010-01-01

    The aim of this study was to report technical details, procedure-related complications, and results of endovascular treatment in chronic iliac artery occlusion. Between 2001 and 2008, endovascular treatments of 127 chronic iliac artery occlusions in 118 patients (8 women and 110 men; mean age, 59 years) were retrospectively reviewed. The study was based on Ad Hoc Committee on Reporting Standards (Society for Vascular Surgery/International Society for Cardiovascular Surgery Standards). All occlusions were treated with stent placement with or without preliminary balloon angioplasty. Kaplan-Meier estimators were used to determine patency rates. Univariate and multivariate analyses were performed to determine variables affecting successful recanalization, major complications, early stent thrombosis (≤30 days), and primary and secondary patency rates. Initial technical success was achieved in 117 (92%) procedures. Successful recanalization was obtained by antegrade approach in 69 of 77 (90%) procedures and by retrograde approach in 52 of 105 (50%) procedures (p < 0.001). Complications were encountered in 28 (24%) patients [minor in 7 patients (6%) and major in 22 patients (19%)]. One death occurred in the operative period secondary to iliac artery rupture. Early stent thrombosis was seen in eight (7%) patients. Presence of critical limb ischemia (p = 0.03), subintimal recanalization (p = 0.03), and major complication (p = 0.02) were the independent predictors of early stent thrombosis on multivariate analysis. Primary and secondary patency rates at 5 years were 63 and 93%, respectively. Presence of critical limb ischemia, TASC type C iliac lesions, combined occlusions of both common and external iliac arteries, and major complications were associated with decreased patency rates on univariate analysis, whereas these factors were not independent predictors of stent patency on multivariate analysis. In conclusion, endovascular treatment of iliac artery occlusion has a

  8. The GuideLiner catheter: A supportive tool in percutaneous coronary intervention of chronic total occlusion

    Directory of Open Access Journals (Sweden)

    Jan-Erik Guelker

    2018-04-01

    Full Text Available Background: Failure of delivering a stent or a balloon across the target lesion during percutaneous coronary intervention (PCI of chronic total occlusion (CTO, especially in arteries with calcified tortuous anatomy, is often due to insufficient backup support from the guiding catheter. The purpose of this study was to assess the feasibility of the GuideLiner (GL catheter use. Methods: We examined 18 patients and used the GL catheter to overcome poor support and excessive friction in standardized antegrade and retrograde CTO procedures. The GL is a coaxial, monorail guiding catheter extension delivered through a standard guiding catheter and is available in different sizes. Results: Almost all lesions were classified as severely calcified (94.4 ± 0.24%. The Japanese CTO score reflecting lesion complexity was 3.56 ± 0.78. All procedures were performed femorally; the retrograde approach was used in 27.8 ± 0.46% of cases. The overall success rate was 88.9 ± 0.32%; there were no relevant complications. Conclusions: The GL catheter is an adjunctive interventional device which enhances and amplifies CTO-PCI. Its use is indicated in cases in which back-up force needs to be strengthened to pass a CTO despite advanced calcification. It can be recommended as an important additional tool in advanced interventional cardiology such as antegrade and retrograde CTO-PCI if other techniques like anchor balloon or anchor wire are not possible. Keywords: Chronic total occlusion, GuideLiner catheter, Percutaneous coronary intervention, Severe calcification

  9. Scientific Ballooning in India - Recent Developments

    Science.gov (United States)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  10. Coil embolization of a false aneurysm with aorto-cutaneous fistula after prosthetic graft replacement of the ascending aorta

    International Nuclear Information System (INIS)

    Miguel, Bruno; Camilleri, Lionel; Gabrillargues, Jean; Macheda, Bruno; Kubota, Hiroshi; Ravel, Anne; Riberolles, Charles de; Boyer, Louis

    2000-01-01

    Aim: To report palliative embolization of a false aneurysm over the distal suture line of an ascending aorta graft replacement. Material and Method: A 78-year-old male patient was admitted for increasing bleeding of a chronic Manubrium ulceration, 20 months after coronary artery bypass complicated by perioperative ascending aorta dissection requiring prosthetic graft replacement. One month later, he underwent epiploplasty for a mediastinitis followed by long-term antibiotic therapy. Five months later, he presented with a Manubrium ulceration of the sternotomy. Spiral computerized tomography (CT) and aortography revealed a 20 mm anterior peri-prosthetic false aneurysm with a wide neck. Advanced age, active mediastinitis and patient's objection led us to perform percutaneous occlusion according to the Moret remodeling technique while protecting the coils release with balloon catheter inflation. Results: No post-operative complication was observed and at 1-year follow-up the patient was doing well with no recurrent bleeding. Magnetic resonance imaging (MRI) and spiral CT controls confirmed coils stability without any internal flow. Conclusion: Percutaneous coils embolization of a large false aneurysm in the ascending aorta can be a palliative treatment in a surgically unsuited patient

  11. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self

  12. Volume-rendered hemorrhage-responsible arteriogram created by 64 multidetector-row CT during aortography: utility for catheterization in transcatheter arterial embolization for acute arterial bleeding.

    Science.gov (United States)

    Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi

    2014-01-01

    Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.

  13. Scientific ballooning in India Recent developments

    Science.gov (United States)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  14. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  15. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  16. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  17. Impairment of left ventricular function during coronary angioplastic occlusion evaluated with a nonimaging scintillation probe.

    Science.gov (United States)

    Hartmann, A; Maul, F D; Zimny, M; Klepzig, H; Vallbracht, C; Kneissl, H G; Schräder, R; Hör, G; Kaltenbach, M

    1991-09-01

    Impairment of left ventricular function during controlled myocardial ischemia induced by coronary angioplasty has been reported from angiographic and echocardiographic studies. Ejection fraction, peak ejection, peak filling rates, and end-systolic and end-diastolic volumes were investigated before, during and after coronary occlusion on-line with a nonimaging scintillation probe. The study consisted of 18 patients (mean age 59 +/- 10 years) with coronary artery stenosis of greater than 70%. During balloon inflation of 60 seconds' duration, coronary occlusion pressure was 31.6 +/- 12 mm Hg. There was no significant change in heart rate. Delay between first and second dilatation was 109 +/- 63 seconds. Ejection fraction decreased from 53 +/- 16 to 40 +/- 12% (first dilatation, p less than 0.01) and to 39 +/- 14% (second dilatation, p less than 0.01) and recovered to 51 +/- 16% 5 minutes after the second dilatation. Peak ejection rate was significantly reduced during the first and second balloon inflations. Peak filling rate decreased from 2.5 +/- 0.8 to 2.0 +/- 0.7 end-diastolic volume.s-1 (first dilatation, p less than 0.01) and to 1.8 +/- 0.7 end-diastolic volume.s-1 (second dilatation, p less than 0.01) and remained reduced at 2.2 +/- 0.7 end-diastolic volume.s-1 (p = not significant) at 5 minutes after the second dilatation. End-systolic and end-diastolic volumes increased significantly during the first and second dilatations and returned to normal after dilatation. It is concluded that short, controlled myocardial ischemia during coronary angioplasty leads to a decrease in systolic and diastolic left ventricular function. Sequential dilatations do not further decrease function if a sufficient interval is kept.

  18. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    Burnett, T.; Iwai, J.; Lord, J.J.; Strausz, S.; Wilkes, R.J.; Dake, S.; Oda, H.; Miyamura, O.; Fuki, M.; Jones, W.V.; Gregory, J.; Hayashi, T.; Takahashi, U.; Tominaga, Y.; Wefel, J.P.; Fountain, W.; Derrickson, J.; Parnell, T.A.; Roberts, E.; Tabuki, T.; Watts, J.W.

    1989-01-01

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  19. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  20. Technologies developed by CNES balloon team

    Science.gov (United States)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  1. Endovascular recanalization of acute intracranial vertebrobasilar artery occlusion using local fibrinolysis and additional balloon angioplasty

    International Nuclear Information System (INIS)

    Kashiwagi, Junji; Okahara, Mika; Kiyosue, Hiro; Tanoue, Shuichi; Sagara, Yoshiko; Mori, Hiromu; Hori, Yuzo; Abe, Toshi

    2010-01-01

    Vertebrobasilar artery occlusion (VBO) produces high mortality and morbidity due to low recanalization rate utilization in endovascular therapy. The use of percutaneous transluminal angioplasty (PTA) to improve recanalization rate additional to local intra-arterial fibrinolysis (LIF) was investigated in this study. Results obtained following recanalization therapy in acute intracranial VBO are reported. Eighteen consecutive patients with acute VBO underwent LIF with or without PTA, from August 2000 to May 2006. Eight patients were treated using LIF alone, and ten required additional PTA. Rate of recanalization, neurological status before treatment, and clinical outcomes were evaluated. Of 18 patients, 17 achieved recanalization. One procedure-related complication of subarachnoid hemorrhage occurred. Overall survival rate was 94.4% at discharge. Seven patients achieved good outcomes [modified Rankin scale (mRS) 0-2], and the other 11 had poor outcomes (mRS 3-6). Five of six patients who scored 9-14 on the Glasgow Coma Scale (GCS) before treatment displayed good outcomes, whereas ten of 12 patients who scored 3-8 on the GCS showed poor outcomes. GCS prior to treatment showed a statistically significant correlation to outcomes (p < 0.05). Moreover, the National Institutes of Health Stroke Scale (NIHSS) before treatment correlated well with mRS (correlation coefficient 0.487). No statistical difference between the good and poor outcome groups was observed for the duration of symptoms, age, etiology, and occlusion site. Endovascular recanalization can reduce mortality and morbidity of acute VBO. Good GCS and NIHSS scores prior to treatment can predict the efficacy of endovascular recanalization. (orig.)

  2. Occlusal risk factors associated with temporomandibular disorders in young adults with normal occlusions.

    Science.gov (United States)

    Wang, Chen; Yin, Xinmin

    2012-10-01

    The aim of this study was to characterize occlusal stability in young adults with temporomandibular disorder (TMD). Thirty-one patients (aged 19-31 years) with complete natural dentition and Angle class I occlusion who exhibited TMD were compared with 31 age- and sex-matched healthy control subjects. The occlusal registrations were performed using the T-Scan II occlusal imaging and analysis system. Center of occlusal force, asymmetry index of occlusal force, maximal movement of COF, premature contacts, clusion time, and disclusion time were recorded. Compared with control subjects, TMD subjects had a significantly higher frequency of premature contacts (16/32, 50.0%) and greater bilateral asymmetry in the occlusal force. Furthermore, prolonged clusion time and disclusion time also were observed in TMD subjects. These results suggest that a significant association exists between occlusal stability and TMD in young adults. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Two Tethered Balloon Systems

    Science.gov (United States)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  4. Recent Developments in Scientific Research Ballooning

    International Nuclear Information System (INIS)

    Jones, W. Vernon

    2007-01-01

    The National Aeronautics and Space Administration (NASA) Balloon Program is committed to meeting the need for extended duration scientific investigations by providing advanced balloon vehicles and support systems. A sea change in ballooning capability occurred with the inauguration of 8 - 20 day flights around Antarctica in the early 1990's. The attainment of 28-31 day flights and a record-breaking 42-day flight in, respectively, two and three circumnavigations of the continent has greatly increased the expectations of the scientific users. A new super-pressure balloon is currently under development for future flights of 60-100 days at any latitude, which would bring another sea change in scientific research ballooning

  5. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  6. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  7. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  8. Solar research with stratospheric balloons

    Science.gov (United States)

    Vázquez, Manuel; Wittmann, Axel D.

    Balloons, driven by hot air or some gas lighter than air, were the first artificial machines able to lift payloads (including humans) from the ground. After some pioneering flights the study of the physical properties of the terrestrial atmosphere constituted the first scientific target. A bit later astronomers realized that the turbulence of the atmospheric layers above their ground-based telescopes deteriorated the image quality, and that balloons were an appropriate means to overcome, total or partially, this problem. Some of the most highly-resolved photographs and spectrograms of the sun during the 20th century were actually obtained by balloon-borne telescopes from the stratosphere. Some more recent projects of solar balloon astronomy will also be described.

  9. Abdominal cavity balloon for preventing a patient's bleeding

    OpenAIRE

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po sitioning the balloon.

  10. Development of a posterior cerebral artery aneurysm subsequent to occlusion of the contralateral internal carotid artery for giant cavernous aneurysm

    International Nuclear Information System (INIS)

    Wolf, R.L.; Hurst, R.W.; Imbesi, S.G.; Galetta, S.L.; Sinson, G.P.; Grossman, R.I.

    2002-01-01

    We report a case of a patient who developed a left posterior cerebral artery aneurysm 5 years after balloon occlusion of the right internal carotid artery for a giant cavernous aneurysm. The location of the new aneurysm was outside of the primary collateral pathways to the contralateral, proximally occluded, anterior circulation, illustrating the complexity of hemodynamic factors contributing to the development of intracranial saccular aneurysms. The appearance of an aneurysm in this setting supports the hypothesis that degenerative factors and hemodynamic stresses are important in the etiology of intracranial aneurysms. (orig.)

  11. Calculating Payload for a Tethered Balloon System

    Science.gov (United States)

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  12. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  13. Optimization of the static occlusion by "occlusal surface settling" in the Cerec 3D software.

    Science.gov (United States)

    Späth, C; Kordass, B

    2006-04-01

    The adjustment of the static occlusion can be automated in computer-based systems. The Cerec 3D software makes it possible to take preformed occlusal surfaces from a database and adapt them to the antagonist. In this adaptation (settling), the CAD occlusal surface "settles" as whole or each cusp individually into the occlusal surface of the antagonist until stable occlusion is reached. Two occlusal surface shapes were compared: Vita Physiodens and Lee Culp. An index was formed from the number, quality, and position of the occlusal contacts for 35 model cases (25 molars, 10 premolars). With regard to the settling of the total occlusal surfaces, there were no differences between the two occlusal surface shapes. In "cusp settling" of the molars, Vita Physiodens performed significantly better. In the comparison of the 1st with the 3rd settling process, significant improvements occurred the 3rd time in many cases when settling individual cusps, but in clearly fewer cases in the settling process of the total occlusal surface. The Lee Culp tooth occlusion improved especially after the 3rd settling process of individual cusps. It is therefore expedient to combine both settling versions with one another.

  14. Stent Recanalization of Chronic Portal Vein Occlusion in a Child

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Solvig, Jan; Schroder, Henrik

    2000-01-01

    An 8-year-old boy with a 21/2 year history of portal hypertension and repeated bleedings from esophageal varices, was referred for treatment. The 3.5-cm-long occlusion of the portal vein was passed and the channel created was stabilized with a balloon-expandable stent; a portosystemic stent-shunt was also created. The portosystemic shunt closed spontaneously within 1 month, while the recanalized segment of the portal vein remained open. The pressure gradient between the intrahepatic and extrahepatic portal vein branches dropped from 17 mmHg to 0 mmHg. The pressure in the portal vein dropped from 30 mmHg to 17 mmHg and the bleedings stopped. The next dilation of the stent was performed 12 months later due to an increased pressure gradient; the gastroesophageal varices disappeared completely. Further dilation of the stent was planned after 2, 4, and 6 years

  15. Ballooning stable high beta tokamak equilibria

    International Nuclear Information System (INIS)

    Tuda, Takashi; Azumi, Masafumi; Kurita, Gen-ichi; Takizuka, Tomonori; Takeda, Tatsuoki

    1981-04-01

    The second stable regime of ballooning modes is numerically studied by using the two-dimensional tokamak transport code with the ballooning stability code. Using the simple FCT heating scheme, we find that the plasma can locally enter this second stable regime. And we obtained equilibria with fairly high beta (β -- 23%) stable against ballooning modes in a whole plasma region, by taking into account of finite thermal diffusion due to unstable ballooning modes. These results show that a tokamak fusion reactor can operate in a high beta state, which is economically favourable. (author)

  16. Scientific ballooning. Proceedings of the symposium on the scientific use of balloons and related technical problems, Innsbruck, Austria, May 29-June 10, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Riedler, W

    1979-01-01

    The book includes works on operational and technical aspects of balloon launching I and II, cooperative balloon campaigns, and new developments in scientific use of balloons. The specific topics discussed are coordinated balloon and rocket measurements of stratospheric wind shears and turbulence, ballooning in Japan and India, magnetospheric processes investigated with data taken from balloon flights, and remote sensing of middle atmosphere winds from balloon platforms.

  17. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  18. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  19. Esophageal achalasia : results of balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-08-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia.

  20. Esophageal achalasia : results of balloon dilation

    International Nuclear Information System (INIS)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young

    1996-01-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia

  1. Endovascular interventions for patients with serious symptoms caused by embolic carotid T occlusion

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Mori, Takahisa; Imai, Keisuke; Izumoto, Hajime

    2011-01-01

    The efficacy of endovascular interventions based on magnetic resonance (MR) imaging for acute ischemic stroke caused by embolic carotid T occlusion was assessed. Endovascular intervention was performed in 10 of 751 consecutive acute ischemic stroke patients admitted to our institution between April 2001 and July 2003. Indications were: presentation within 6 hours of onset of cardioembolic stroke; National Institute of Health Stroke Scale (NIHSS) score ≥10 on admission; absence of extensive signal hyperintenity on diffusion-weighted imaging; and carotid T occlusion on angiography. Localized intra-arterial thrombolysis using urokinase and/or mechanical clot disruption using micro-balloon catheter were performed. Radiographic findings, ΔNIHSS defined as NIHSS on day 7- NIHSS on admission, 3-month modified Rankin scale (mRS), 3-month mortality, and symptomatic intracranial hemorrhage (ICH) were evaluated. Partial recanalization was achieved in 5 of 10 patients, but no recanalization was obtained in 5 patients. No significant differences in 3-month mRS (0-2) or symptomatic ICH were identified between these groups. However, the partial recanalization group showed significantly better clinical outcomes (median 3-month mRS 3 vs. 6, p=0.009) and lower mortality rate at 90 days (0% vs. 80%, p=0.047) with significantly greater ΔNIHSS (-8 vs. +6, p=0.009). Endovascular intervention based on MR imaging resulting in partial recanalization may reduce poor outcomes and mortality in patients with embolic carotid T occlusion. Improvement of the outcomes of such patients requires more efficient methods such as clot retrieval therapy. (author)

  2. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  3. Early Cosmic Ray Research with Balloons

    Science.gov (United States)

    Walter, Michael

    2013-06-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  4. Early Cosmic Ray Research with Balloons

    International Nuclear Information System (INIS)

    Walter, Michael

    2013-01-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster

  5. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  6. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  7. Minocycline Effectively Protects the Rabbit's Spinal Cord From Aortic Occlusion-Related Ischemia.

    Science.gov (United States)

    Drenger, Benjamin; Fellig, Yakov; Ben-David, Dror; Mintz, Bella; Idrees, Suhel; Or, Omer; Kaplan, Leon; Ginosar, Yehuda; Barzilay, Yair

    2016-04-01

    To identify the minocycline anti-inflammatory and antiapoptotic mechanisms through which it is believed to exert spinal cord protection during aortic occlusion in the rabbit model. An animal model of aortic occlusion-related spinal cord ischemia. Randomized study with a control group and pre-ischemia and post-ischemia escalating doses of minocycline to high-dose minocycline in the presence of either hyperglycemia, a pro-apoptotic maneuver, or wortmannin, a specific phosphatidylinositol 3-kinase antagonist. Tertiary medical center and school of medicine laboratory. Laboratory animals-rabbits. Balloon obstruction of infrarenal aorta introduced via femoral artery incision. Severe hindlimb paralysis (mean Tarlov score 0.36±0.81 out of 3) was observed in all the control group animals (9 of 11 with paraplegia and 2 of 11 with paraparesis) compared with 11 of 12 neurologically intact animals (mean Tarlov score 2.58±0.90 [p = 0.001 compared with control]) in the high-dose minocycline group. This protective effect was observed partially during a state of hyperglycemia and was completely abrogated by wortmannin. Minocycline administration resulted in higher neurologic scores (p = 0.003) and a shift to viable neurons and more apoptotic-stained nuclei resulting from reduced necrosis (p = 0.001). In a rabbit model of infrarenal aortic occlusion, minocycline effectively reduced paraplegia by increasing the number of viable neurons in a dose-dependent manner. Its action was completely abrogated by inhibiting the phosphatidylinositol 3-kinase pathway and was inhibited partially by the pro-apoptotic hyperglycemia maneuver, indicating that the activation of cell salvage pathways and mitochondrial sites are possible targets of minocycline action in an ischemic spinal cord. Copyright © 2016. Published by Elsevier Inc.

  8. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  9. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  10. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Anderson localization and ballooning eigenfunctions

    International Nuclear Information System (INIS)

    Dewar, R.L.; Cuthbert, P.

    1999-01-01

    In solving the ballooning eigenvalue for a low-aspect-ratio stellarator equilibrium it is found that the quasiperiodic behaviour of the equilibrium quantities along a typical magnetic field line can lead to localization of the ballooning eigenfunction (Anderson localization) even in the limit of zero shear. This localization leads to strong field-line dependence of the ballooning eigenvalue, with different branches attaining their maximum growth rates on different field lines. A method is presented of estimating the field-line dependence of various eigenvalue branches by using toroidal and poloidal symmetry operations on the shear-free ballooning equation to generate an approximate set of eigenfunctions. These zero-shear predictions are compared with accurate numerical solutions for the H-1 Heliac and are shown to give a qualitatively correct picture, but finite shear corrections will be needed to give quantitative predictions

  12. Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART)

    International Nuclear Information System (INIS)

    Zorger, N.; Lenhart, M.; Strotzer, M.; Paetzel, C.; Hamer, O.; Feuerbach, S.; Link, J.

    2002-01-01

    Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p [de

  13. Effect of occlusion amblyopia after prescribed full-time occlusion on long-term visual acuity outcomes.

    Science.gov (United States)

    Longmuir, Susannah; Pfeifer, Wanda; Scott, William; Olson, Richard

    2013-01-01

    To investigate the incidence and characteristics of occlusion amblyopia with prescribed full-time patching and determine its effect on long-term visual acuity outcomes. The records of patients younger than 10 years diagnosed as having amblyopia between 1970 and 2000 were retrospectively reviewed. Patients were prescribed full-time occlusion and observed until completion of therapy. Of 597 patients treated for amblyopia by full-time patching, 115 were diagnosed as having occlusion amblyopia (19.3%). Seventy-five percent (86 of 115) developed occlusion amblyopia during the first episode of full-time patching. Occlusion amblyopia occurred more frequently in children prescribed full-time patching at an earlier age (P = .0002), with an odds ratio of 8.56 (95% confidence interval: 2.73, 26.84) in children younger than 36 months and 2.66 (95% confidence interval: 0.96, 7.37) in children between 36 and 59 months old. Seven of the patients with occlusion amblyopia did not reverse fixation and continued to fixate with the initially amblyopic eye after treatment. Final visual acuity in these eyes with occlusion amblyopia was 20/30 or better. After cessation of treatment, the final interocular difference in visual acuity was less in patients with a history of occlusion amblyopia (P = .003). Occlusion amblyopia occurred at all ages, but the incidence decreased with increasing age. Patients who developed occlusion amblyopia with prescribed full-time occlusion had less interocular visual acuity difference than patients who did not, suggesting that development of occlusion amblyopia can indicate the potential for the development of better vision in the originally amblyopic eye. Copyright 2013, SLACK Incorporated.

  14. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  15. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    Science.gov (United States)

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  16. Recent activities on the scientific ballooning in Japan

    International Nuclear Information System (INIS)

    Nisimura, J.; Hirosawa, H.

    1984-01-01

    Scientific ballooning is Japan has been organized by the Institute of Space and Astronautical Science, and about 15 balloons have been launched each year from Sanriku Balloon Center that belongs to this Institute. The balloon center is located in the northern part of Japan. The observations cover the field of X-ray, gamma-ray, infrared astronomy, cosmic rays, and atmospheric science. Systems of lon duration flights such as 'Boomerang Balloons', and fine attitude control systems were developed and widely applied to the scientific observations. International collaborative works were performed in Australia and Indonesia last year. Some details of these activities are reported and possible future collaborations with Braziian balloon group are also discussed. (Author) [pt

  17. The French balloon and sounding rocket space program

    Science.gov (United States)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  18. TMBM: Tethered Micro-Balloons on Mars

    Science.gov (United States)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  19. Overview of the NASA balloon R&D program

    Science.gov (United States)

    Smith, I. Steve, Jr.

    1994-01-01

    The catastrophic balloon failure during the first half of the 1980's identified the need for a comprehensive and continuing balloon research and development (R&D) commitment by NASA. Technical understanding was lacking in many of the disciplines and processes associated with scientific ballooning. A comprehensive balloon R&D plan was developed in 1986 and implemented in 1987. The objectives were to develop the understanding of balloon system performance, limitations, and failure mechanisms. The program consisted of five major technical areas: structures, performance and analysis, materials, chemistry and processing, and quality control. Research activitites have been conducted at NASA/Goddard Space Flight Center (GSFC)-Wallops Flight Facility (WFF), other NASA centers and government facilities, universities, and the balloon manufacturers. Several new and increased capabilities and resources have resulted from this activity. The findings, capabilities, and plan of the balloon R&D program are presented.

  20. Balloon pulmonary valvotomy – Not just a simple balloon dilatation

    Directory of Open Access Journals (Sweden)

    Subhendu Mohanty

    2014-07-01

    Full Text Available Balloon pulmonary valvotomy is the preferred mode of treatment in patients with isolated pulmonary valvar stenosis and has shown good long term results. It is generally considered a safe procedure with few complications. There have been however, case reports of potentially fatal acute severe pulmonary edema occurring after the procedure in some patients. The cause of this complication and its pathophysiology is still not clear. Its occurrence is also infrequent with less than 5 cases reported till now. We report a case of pulmonary valvar stenosis which developed acute severe refractory pulmonary edema immediately after balloon pulmonary valvotomy.

  1. Occlusal stability in shortened dental arches.

    Science.gov (United States)

    Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F

    2001-02-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.

  2. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    Gorham, Peter W.

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  3. Laser welding of balloon catheters

    Science.gov (United States)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  4. NASA Langley Research Center tethered balloon systems

    Science.gov (United States)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  5. Heat Transfer Model for Hot Air Balloons

    Science.gov (United States)

    Llado-Gambin, Adriana

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.

  6. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  7. Gigantic balloon type artificial lightning generator

    Energy Technology Data Exchange (ETDEWEB)

    Horii; kenji

    1988-09-05

    This paper outlines a hot-air balloon type Van de Graaf 50-MV generator which can generate a 50,000,000 V, 0.2 to 0.3 coulomb artificial lightning comparable to natural lightning discharge and reports the results of investigation on discharging experiments conducted using this apparatus. The subjects covered are as follows: (1) Outline of the hot-air balloon type Van de Graaf 50-MV generator, (2) electric characteristics of the Van de Graaf 50-MV generator, (3) charge transfer with film and balloon charging, (4) the load of the balloon and buoyancy calculation, (5) leakage of charges, (6) study of charging experiments, and (7) evaluation of the apparatus and its method and problems to be solved. (4 figs, 4 tabs, 4 refs)

  8. Evaluation of bone loss due to primary occlusal trauma in two experimental models of occlusal overload

    OpenAIRE

    LOPES, Ana Cristina Távora de Albuquerque; TÉO, Mirela Anne Quartaroli; CORRÊA, Mônica Grazieli; ISHIKIRIAMA, Bella Luna Colombini; CAMPOS, Mirella Lindoso Gomes

    2016-01-01

    Abstract Introduction Primary occlusal trauma (OT) is an injury of the periodontium with normal height as a result of occlusal forces which exceed their adaptive capacity. Objective To evaluate, histometrically, the alveolar bone loss in the furcation region of rats experimentally submitted to 2 models of occlusal overload. Material and method 45 animals randomly divided into 3 groups: Occlusal Interference (OI, n = 15) - fixing an orthodontic wire segment on the occlusal surface of the fi...

  9. Balloon cell nevus of the iris.

    Science.gov (United States)

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  10. TIPS Placement via Combined Transjugular and Transhepatic Approach for Cavernous Portal Vein Occlusion: Targeted Approach

    Directory of Open Access Journals (Sweden)

    Natanel Jourabchi

    2013-01-01

    Full Text Available Purpose. We report a novel technique which aided recanalization of an occluded portal vein for transjugular intrahepatic portosystemic shunt (TIPS creation in a patient with symptomatic portal vein thrombosis with cavernous transformation. Some have previously considered cavernous transformation a contraindication to TIPS. Case Presentation. 62-year-old man with chronic pancreatitis, portal vein thrombosis, portal hypertension and recurrent variceal bleeding presents with melena and hematemesis. The patient was severely anemic, hemodynamically unstable, and required emergent portal decompression. Attempts to recanalize the main portal vein using traditional transjugular access were unsuccessful. After percutaneous transhepatic right portal vein access and navigation of a wire through the occluded main portal vein, an angioplasty balloon was inflated at the desired site of shunt takeoff. The balloon was targeted and punctured from the transjugular approach, and a wire was passed into the portal system. TIPS placement then proceeded routinely. Conclusion. Although occlusion of the portal vein increases difficulty of performing TIPS, it should not be considered an absolute contraindication. We have described a method for recanalizing an occluded portal vein using a combined transhepatic and transjugular approach for TIPS. This approach may be useful to relieve portal hypertension in patients who fail endoscopic and/or surgical therapies.

  11. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  12. Vertical sounding balloons for stratospheric photochemistry

    Science.gov (United States)

    Pommereau, J. P.

    The use of vertical sounding balloons for stratospheric photochemistry studies is illustrated by the use of a vertical piloted gas balloon for the search of NO2 diurnal variations. It is shown that the use of montgolfieres (hot air balloons) can enhance the vertical sounding technique. Particular attention is given to a sun-heated montgolfiere and to the more sophisticated infrared montgolfiere that is able to perform three to four vertical excursions per day and to remain aloft for weeks or months.

  13. Vertebrobasilar Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Schoen, Jessica

    2011-05-01

    Full Text Available The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. [West J Emerg Med. 2011;12(2:233-239.

  14. Boston's balloon dilatation for treatment of cardiac achalasia

    International Nuclear Information System (INIS)

    Yin Jianguo; Song Jinwen; Yang Yan; Liu Xiaohong; Fu Zhiming; Zhang Yaqin

    2001-01-01

    Objective: To review and summarize effectiveness and method of the Boston's balloon dilation in cardiac achalasia. Methods: The intensified guide wire was inserted into stomach through mouth cavity under TV control. The Boston's balloon was inserted to the cardiac stricture through the guide wire and dilatated with 15% contrast medium with to a maximum diameter for five minutes and then the balloon was dilatated again for 3-5 minutes, all together for 3-4 times. The severe stricture must be pre-dilatated with 20-25 mm diameter balloon. Results: The balloon insertion was technically successful in all 26 patients. The once success of balloon dilation was achieved in 24 patients and twice in other 2. Follow-up time was from 2 weeks to 31 months (mean 10.6 months). Recurrent stenosis had not occurred in all patients. Remission rate of dysphagia was 100%. Esophageal reflux occurred in 3 patients. Conclusions: The Boston's balloon dilatation is simple and effective for treatment of cardiac achalasia. The method sometimes may replace surgical procedure

  15. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  16. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  17. Development of a Super-Pressure Balloon with an Improved Design

    Science.gov (United States)

    Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya

    A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.

  18. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  19. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  20. Primary stent placement for recanalization of iliac artery occlusions: Using a self-expanding spiral stent

    International Nuclear Information System (INIS)

    Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun

    1999-01-01

    Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.

  1. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    Science.gov (United States)

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Maximizing mandibular prosthesis stability utilizing linear occlusion, occlusal plane selection, and centric recording.

    Science.gov (United States)

    Williamson, Richard A; Williamson, Anne E; Bowley, John; Toothaker, Randy

    2004-03-01

    The stability of mandibular complete dentures may be improved by reducing the transverse forces on the denture base through linear (noninterceptive) occlusion, selecting an occlusal plane that reduces horizontal vectors of force at occlusal contact, and utilizing a central bearing intraoral gothic arch tracing to record jaw relations. This article is intended to acquaint the reader with one technique for providing stable complete denture prostheses using the aforementioned materials, devices, and procedures.

  3. Contralateral Occlusion Test: The effect of external ear canal occlusion on hearing thresholds.

    Science.gov (United States)

    Reis, Luis Roque; Fernandes, Paulo; Escada, Pedro

    Bedside testing with tuning forks may decrease turnaround time and improve decision making for a quick qualitative assessment of hearing loss. The purpose of this study was to quantify the effects of ear canal occlusion on hearing, in order to decide which tuning fork frequency is more appropriate to use for quantifying hearing loss with the Contralateral Occlusion Test. Twenty normal-hearing adults (forty ears) underwent sound field pure tone audiometry with and without ear canal occlusion. Each ear was tested with the standard frequencies. The contralateral ear was suppressed with by masking. Ear occlusion was performed by two examiners. Participants aged between 21 and 30 years (25.6±3.03 years) showed an increase in hearing thresholds with increasing frequencies from 19.94dB (250Hz) to 39.25dB (2000Hz). The threshold difference between occluded and unoccluded conditions was statistically significant and increased from 10.69dB (250Hz) to 32.12dB (2000Hz). There were no statistically significant differences according to gender or between the examiners. The occlusion effect increased the hearing thresholds and became more evident with higher frequencies. The occlusion method as performed demonstrated reproducibility. In the Contralateral Occlusion Test, 256Hz or 512Hz tuning forks should be used for diagnosis of mild hearing loss, and a 2048Hz tuning fork should be used for moderate hearing loss. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  4. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  5. Balloon launching station, Mildura, Victoria

    International Nuclear Information System (INIS)

    The Mildura Balloon Launching Station was established in 1960 by the Department of Supply (now the Department of Manufacturing Industry) on behalf of the United States Atomic Energy Commission (USAEC) to determine the content of radioactive material in the upper atmosphere over Australia. The Station location and layout, staffing, balloon launching equipment, launching, tracking and recovery are described. (R.L.)

  6. Efficacy and safety of balloon-occluded retrograde transvenous obliteration with sodium tetradecyl sulfate liquid sclerotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Park, Sang Woo; Kwon, So Young; Cheo, Won Hyeok; Cheon, Young Koog; Shim, Chan Sup; Lee, Tae Yoon; Kim, Jeong Han [Digestive Disease Center, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    To evaluate the efficacy and safety of balloon-occluded retrograde transvenous obliteration (BRTO) with sodium tetradecyl sulfate (STS) liquid sclerotherapy of gastric varices. Between February 2012 and August 2014, STS liquid sclerotherapy was performed in 17 consecutive patients (male:female = 8:9; mean age 58.6 years, range 44-86 years) with gastric varices. Retrograde venography was performed after occlusion of the gastrorenal shunt using a balloon catheter and embolization of collateral draining veins using coils or gelfoam pledgets, to evaluate the anatomy of the gastric varices. We prepared 2% liquid STS by mixing 3% STS and contrast media in a ratio of 2:1. A 2% STS solution was injected into the gastric varices until minimal filling of the afferent portal vein branch was observed (mean 19.9 mL, range 6-33 mL). Patients were followed up using computed tomography (CT) or endoscopy. Technical success was achieved in 16 of 17 patients (94.1%). The procedure failed in one patient because the shunt could not be occluded due to the large diameter of gastrorenal shunt. Complete obliteration of gastric varices was observed in 15 of 16 patients (93.8%) with follow-up CT or endoscopy. There was no rebleeding after the procedure. There was no procedure-related mortality. BRTO using STS liquid can be a safe and useful treatment option in patients with gastric varices.

  7. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  8. [Balloon cell nevi of the conjunctiva (author's transl)].

    Science.gov (United States)

    Schlageter, P E; Daicker, B

    1975-06-01

    The clinical and histological features of three cases of conjunctival balloon cell nevi are described. This peculiar form of nevus is very rare in the conjunctiva. The findings are compared with the descriptions in the literature of dermal balloon cell nevi. They demonstrate, that the conjunctival and dermal tumours are of idential histological structure. The proliferations of the conjunctival epithelium often found in conjunctival nevi do not modify the balloon cell nevi. These can not be diagnosed clinically. The problems of the pathogenesis of the balloon cell nevi are discussed.

  9. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  10. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    Science.gov (United States)

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  11. Retained intraaortic balloon. Case report and review of the literature.

    Science.gov (United States)

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  12. Upper gastrointestinal strictures: The results of balloon dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Woo; Lim, Hyo Keun; Choo, In Wook; Bae, Sang Hoon; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of); Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Balloon catheter dilatation of upper gastrointestinal strictures is an accepted mode of therapy. The authors report the balloon dilatation in 11 consecutive patients. The lesions treated included 10 benign strictures, and 1 esophageal cancer. Esophageal balloon were ranged from 2 mm in diameter, 4 cm in length, to 30 mm in diameter, 8 cm in length. Inflation was held for from 30 to 60 seconds and then repeated two or three times during each session. The balloons were inflated to pressure of from 2 to 12 atmospheres. There were from 1 to 13 dilatations. Two esophageal perforations were occurred in one esophagitis patient and other lye stricture patient. Two perforations were not required any surgical repair. All dilatation were performed without anesthesia. All strictures were responded immediately to dilatation. Prolonged course of treatment were needed with chronic severe esophagitis, lye stricture, gastrojejunostomy with chemotherapy, as a result, all patients, except esophageal cancer, could take regular diet after balloon catheter dilatation. Balloon catheter dilatation of upper gastrointestinal stenosis was effective and safe. It should be considered before other methods of treatment applicable.

  13. One-year clinical evaluation of nanohybrid resin composite in the restoration of occlusal and proximo-occlusal cavities in Nigeria

    Directory of Open Access Journals (Sweden)

    Lillian Lami Enone

    2017-01-01

    Full Text Available Background: This study aimed to evaluate the clinical performance of nanocomposites in a Nigerian adult population. Resin composites are becoming the preferred direct restorative material in restoring occlusal and proximo-occlusal cavities due to their aesthetic properties and good clinical service. Materials and Methods: This was a clinical study evaluating the clinical performance of a nanohybrid resin composite in the restoration of occlusal and proximo-occlusal cavities in Nigerian adults. This study was done in the Conservative Dentistry Clinic of the Lagos State University Teaching Hospital, Ikeja, from April 2014 to September 2015. The restorations were evaluated immediately at baseline, 3, 6 and 12 months postoperatively for colour match, marginal discolouration, surface roughness, anatomical form, marginal adaptation, retention, post-operative sensitivity and secondary caries using the modified USPHS criteria. Statistical analysis was performed using Fisher's exact test and a 5% level of significance was considered statistically significant. Results: Males had more proximo-occlusal (26.7 than occlusal (6.7 cavities while the females (43.3 had more occlusal cavities. The nanohybrid occlusal restorations had 100% alpha scores at baseline for anatomical form which dropped to 93.3% at 12 months with 6.7% of the restorations scoring Bravo, whereas all nanohybrid proximo-occlusal restorations had 100% alpha scores from baseline to the 12-month review. All occlusal and proximo-occlusal restorations evaluated for surface texture and marginal adaptation had alpha scores at baseline which dropped to 93.3% at 12 months. Conversely, all nanohybrid occlusal and proximo-occlusal restorations scored 100% for colour match and retention, sensitivity and secondary caries from baseline to 12 months. Conclusion: The clinical performance of natural elegance nanohybrid resin composite (Henry Schein® was satisfactory in the restoration of occlusal and

  14. Percutaneous balloon dilation of pulmonary stenosis

    International Nuclear Information System (INIS)

    Hua Yangde; Huang Ming; Li Jinkang; Qian Jinqing; Chen Xiuyu; Yang Siyuan

    2003-01-01

    Objective: Review our experience of balloon dilation of valvular pulmonary stenosis in 32 cases. Methods: Totally 32 cases of pulmonary stenosis admitted from 1995-2001 with age of 1.5-13 yrs mean 6.8. Diagnosis was made by clinical manifestations, EKG, ECHO and angiocardiography. Results: Before dilation, the mean systolic pressure of right ventricle was (93.5 ± 28.5) mmHg, after the procedure it reduced to (42 ± 9.0) mmHg. The pressure gradient between right ventricle and pulmonary artery before dilation was (76 ± 30) mmHg and become (24.5 ± 8.5) mmHg after dilation. The gradient pressure after dilation was less than 25 mmHg in 90.6% cases. A case of Noonan syndrome showed no response to balloon dilation and died during valvulectomy from accompanying left ventricular cardiomyopathy. Conclusions: Balloon dilation of valvular pulmonary stenosis is effective and safe. The selection of proper diameter of pulmonary valvular rings and sized of the balloon are the major factors

  15. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  16. Balloon dilatation of ureteric strictures.

    Directory of Open Access Journals (Sweden)

    Punekar S

    2000-01-01

    Full Text Available AIMS: Evaluation of dilatation as a minimally invasive technique for the treatment of ureteric strictures. MATERIAL AND METHODS: We evaluated this technique in 16 patients with ureteric and secondary pelviureteric junction strictures from June 1998. Of these, 7 were men and 9 were women. The age range was from 14 to 40 years. RESULTS: Balloon dilatation was successful in 69% of patients. Strictures secondary to previous surgery had nearly 100% success. Of the 8 cases diagnosed as genitourinary tuberculosis, success rate was 50%. CONCLUSIONS: Factors affecting success of balloon dilatation are: a age of the stricture b length of the stricture and c etiology of the stricture. In a select group of patients with fresh post-operative or post-inflammatory strictures, balloon dilatation may be an attractive alternative to surgery.

  17. Recurrence of amblyopia after occlusion therapy.

    Science.gov (United States)

    Bhola, Rahul; Keech, Ronald V; Kutschke, Pamela; Pfeifer, Wanda; Scott, William E

    2006-11-01

    To determine the stability of visual acuity (VA) after a standardized occlusion regimen in children with strabismic and/or anisometropic amblyopia. Retrospective, population-based, consecutive observational case series. Four hundred forty-nine patients younger than 10 years who underwent an occlusion trial for amblyopia and were observed until there was a recurrence of amblyopia or for a maximum of 1 year after decrease or cessation of occlusion therapy. We performed a retrospective chart review of all patients treated by occlusion therapy for strabismic and/or anisometropic amblyopia at our institution over a 34-year period. Of the 1621 patients identified in our database, 449 met the eligibility criteria and were included in this study. Patients having at least a 2 logarithm of the minimum angle of resolution (logMAR)-level improvement in VA by optotypes or a change from unmaintained to maintained fixation preference during the course of occlusion therapy were included. A recurrence of amblyopia was defined as > or =2 logMAR levels of VA reduction or reversal of fixation preference within 1 year after a decrease or cessation of occlusion therapy. Recurrence of amblyopia after a decrease or cessation of occlusion therapy and its relationship with patient age and VA of the amblyopic eye at the time of decrease or cessation of occlusion therapy. Of 653 occlusion trials, 179 (27%) resulted in recurrence of amblyopia. The recurrence was found to be inversely correlated with patient age. There was no statistically significant association between the recurrence of amblyopia and VA of the amblyopic eye at the end of maximal occlusion therapy. There is a clinically important risk of amblyopia recurrence when occlusion therapy is decreased before the age of 10 years. The risk of recurrence is inversely correlated with age (P<0.0001).

  18. Plasma Glucose Level Is Predictive of Serum Ammonia Level After Retrograde Occlusion of Portosystemic Shunts.

    Science.gov (United States)

    Ishikawa, Tsuyoshi; Aibe, Yuki; Matsuda, Takashi; Iwamoto, Takuya; Takami, Taro; Sakaida, Isao

    2017-09-01

    The purpose of this study was to evaluate predictors of reduction in ammonia levels by occlusion of portosystemic shunts (PSS) in patients with cirrhosis. Forty-eight patients with cirrhosis (21 women, 27 men; mean age, 67.8 years) with PSS underwent balloon-occluded retrograde transvenous obliteration (BRTO) at one institution between February 2008 and June 2014. The causes of cirrhosis were hepatitis B in one case, hepatitis C in 20 cases, alcohol in 15 cases, nonalcoholic steatohepatitis in eight cases, and other conditions in four cases. The Child-Pugh classes were A in 24 cases, B in 23 cases, and C in one case. The indication for BRTO was gastric varices in 40 cases and hepatic encephalopathy in eight cases. Testing was conducted before and 1 month after the procedure. Statistical analyses were performed to identify predictors of a clinically significant decline in ammonia levels after BRTO. Occlusion of PSS resulted in a clinically significant decrease in ammonia levels accompanied by increased portal venous flow and improved Child-Pugh score. Univariate analyses showed that a reduction in ammonia levels due to BRTO was significantly related to lower plasma glucose levels, higher RBC counts, and higher hemoglobin concentration before the treatment. Furthermore, multivariate logistic regression identified preoperative plasma glucose level as the strongest independent predictor of a significant ammonia reduction in response to BRTO. In addition, although BRTO resulted in significantly declined ammonia levels in patients with normal glucose tolerance before the procedure, ammonia levels were not significantly decreased after shunt occlusion in patients with diabetes mellitus or impaired glucose tolerance before BRTO, according to 75-g oral glucose tolerance test results. Preoperative plasma glucose level is a useful predictor of clinically significant ammonia reduction resulting from occlusion of PSS in patients with cirrhosis. Even if PSS are present, control

  19. Evaluation of bone loss due to primary occlusal trauma in two experimental models of occlusal overload

    Directory of Open Access Journals (Sweden)

    Ana Cristina Távora de Albuquerque LOPES

    Full Text Available Abstract Introduction Primary occlusal trauma (OT is an injury of the periodontium with normal height as a result of occlusal forces which exceed their adaptive capacity. Objective To evaluate, histometrically, the alveolar bone loss in the furcation region of rats experimentally submitted to 2 models of occlusal overload. Material and method 45 animals randomly divided into 3 groups: Occlusal Interference (OI, n = 15 - fixing an orthodontic wire segment on the occlusal surface of the first lower molar; Occlusal Overload (OO, n = 15 - wearing of the cusps of the lower contralateral molars, the second and third molars next to the first molar that had its dimensions maintained; Negative Control (NC, n = 15 - evaluation of the initial dimensions of the periodontal ligament (PL. Five animals / group were sacrificed after 14, 21 and 28 days. Result Intergroup evaluation showed significant bone loss in OI (p0.05. The thickness of the PL remained stable in NC (p>0.05. Conclusion OI and OO were effective in the experimental reproduction of OT, and OI promoted greater alveolar bone loss compared to OO, showing that the impact of occlusal overload in OI increased the extent of the OT injury.

  20. Occlusion effects, Part I

    DEFF Research Database (Denmark)

    Hansen, Mie Østergaard

    annoyances and the objective measurements were analysed. Persons suffering from tinnitus behaved differently than person without tinnitus. The latter group showed significant relations between the measured occlusion effect, hearing loss and the personal of occlusion. The actual sensation level is also...

  1. Properties of ballooning modes in the Heliotron configurations

    International Nuclear Information System (INIS)

    Nakajima, N.; Hudson, S.R.; Hegna, C.C.

    2005-01-01

    The stability of ballooning modes is influenced by the local and global magnetic shear and local and global magnetic curvature so significantly that it is fairly difficult to get those general properties in the three dimensional configurations with strong flexibility due to the external coil system. In the case of the planar axis heliotron configurations allowing a large Shafranov shift, like LHD, properties of the high-mode-number ballooning modes have been intensively investigated. It has been analytically shown that the local magnetic shear comes to disappear in the stellarator-like global magnetic shear region, as the Shafranov shift becomes large. Based on this mechanism and the characteristics of the local and global magnetic curvature, it is numerically shown that the destabilized ballooning modes have strong three-dimensional properties (both poloidal and toroidal mode couplings) in the Mercier stable region, and that those are fairly similar to ballooning modes in the axisymmetric system in the Mercier unstable region. As is well known, however, no quantization condition is applicable to the ballooning modes in the three-dimensional system without symmetry, and so the results of the high-mode-number ballooning modes in the covering space had to be confirmed in the real space. Such a confirmation has been done in the Mercier stable region and also in the Mercier unstable region by using three dimensional linearized ideal MHD stability code cas3d. Confirming the relation between high-mode-number ballooning analyses by the global mode analyses, the method of the equilibrium profile variations has been developed in the tree dimensional system, giving dt/dψ - dP/dψ stability diagram corresponding to the s - α diagram in tokamaks. This method of profile variation are very powerful to investigate the second stability of high-mode-number ballooning modes and has been more developed. Recently it has been applied to the plasma in the inward-shifted LHD

  2. [Temporomandibular joint, occlusion and bruxism].

    Science.gov (United States)

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. Analysis of Flight of Near-Space Balloon

    Science.gov (United States)

    Miller, Zech; Evans, Austin; Seyfert, James; Leadlove, Kyle; Gumina, Kaitlyn; Martell, Eric

    2015-04-01

    In December 2014, the Electronics class at Millikin University launched a balloon designed to travel into the near-space region of the atmosphere. The balloon was equipped with an instrumentation package including a camera, accelerometer, barometric pressure sensor, temperature probes, as well as a system for tracking using an Automatic Packet Reporting System (APRS). The balloon was launched from Decatur, IL, and landed in Marysville, OH, nearly 320 miles away. The students then analyzed the data from the flight and compared results to expectations.

  4. Heat Transfer Model for Hot Air Balloons

    OpenAIRE

    Lladó Gambín, Adriana

    2016-01-01

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the mod...

  5. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  6. Treatment of temporomandibular disorder using occlusal splint

    Directory of Open Access Journals (Sweden)

    Agus Dahlan

    2009-03-01

    Full Text Available Background: Patient suffering from occlusal abnormality is usually detected months or even years when the acute patient visits a dentist, and generally the patient does not receive direct treatment upon his complaints since minimum information is available on this type of treatment. In general, the dentist provides medication only or conducts incorrect selective grinding where in fact, the patient does not feel better from the previous conditions. Purpose: The objective of this study is to discuss the treatment on the dysfunctional temporomandibular joint followed by orofacial pain caused by occlusal disorder using occlusal splint. Case: In this case, a forty three years old male having trouble with the joint on the left jaw followed by orofacial pain caused by occlusal disorder. Case Management: Initial treatment with occlusal splint makes the patient comfortable and recovers from his complaints since the patient could restructure the chewing muscles. This treatment will be more successful if the dentist has the knowledge to use and choose occlusal splint method properly. Occlusal Splint could be used as a supporting therapy and consideration as one of the therapies to avoid the unwanted side effects. The use of occlusal splint is meant as an alternative of the main therapy in overcoming the problem of occlusal splint. Conclusion: Finally, therapy with occlusal splint is very effective as an alternative treatment to handle the dysfunction of temporomandibular joint caused by occlusion.

  7. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  8. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  9. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  10. Introduction (Special Issue on Scientific Balloon Capabilities and Instrumentation)

    Science.gov (United States)

    Gaskin, Jessica A.; Smith, I. S.; Jones, W. V.

    2014-01-01

    In 1783, the Montgolfier brothers ushered in a new era of transportation and exploration when they used hot air to drive an un-tethered balloon to an altitude of 2 km. Made of sackcloth and held together with cords, this balloon challenged the way we thought about human travel, and it has since evolved into a robust platform for performing novel science and testing new technologies. Today, high-altitude balloons regularly reach altitudes of 40 km, and they can support payloads that weigh more than 3,000 kg. Long-duration balloons can currently support mission durations lasting 55 days, and developing balloon technologies (i.e. Super-Pressure Balloons) are expected to extend that duration to 100 days or longer; competing with satellite payloads. This relatively inexpensive platform supports a broad range of science payloads, spanning multiple disciplines (astrophysics, heliophysics, planetary and earth science.) Applications extending beyond traditional science include testing new technologies for eventual space-based application and stratospheric airships for planetary applications.

  11. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  12. Taking the Hot Air Out of Balloons.

    Science.gov (United States)

    Brinks, Virgil L.; Brinks, Robyn L.

    1994-01-01

    Describes how a teacher can give their students the challenge of designing and building model balloons or blimps. The project helps students learn the basics of balloon flight and what it really means to be "lighter than air." (PR)

  13. Hydrogel based occlusion systems

    NARCIS (Netherlands)

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A.; Mendes, E.; Neves, H.P.; Herijgers, P.; Verbrugghe, Y.; Shacham, Y.; Engel, L.; Krylov, V.

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a

  14. Paraplegia following intraaortic balloon circulatory assistance

    Directory of Open Access Journals (Sweden)

    Benício Anderson

    1999-01-01

    Full Text Available Intraaortic balloon counterpulsation is frequently used in patients experiencing severe ventricular dysfunction following maximal drug therapy. However, even with the improvement of percutaneous insertion techniques, the procedure has always been followed by vascular, infectious, and neurological complications. This article describes a case of paraplegia due to intraaortic balloon counterpulsation in the postoperative period of cardiac surgery.

  15. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  16. Reduction of prostate intrafraction motion using gas-release rectal balloons

    International Nuclear Information System (INIS)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy

    2012-01-01

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5Σ+ 0.7σ to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior–inferior (SI) and anterior–posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left–right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  17. Reduction of prostate intrafraction motion using gas-release rectal balloons

    Energy Technology Data Exchange (ETDEWEB)

    Su Zhong; Zhao Tianyu; Li Zuofeng; Hoppe, Brad; Henderson, Randy; Mendenhall, William; Nichols, R. Charles; Marcus, Robert; Mendenhall, Nancy [Department of Radiation Oncology, University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States)

    2012-10-15

    Purpose: To analyze prostate intrafraction motion using both non-gas-release (NGR) and gas-release (GR) rectal balloons and to evaluate the ability of GR rectal balloons to reduce prostate intrafraction motion. Methods: Twenty-nine patients with NGR rectal balloons and 29 patients with GR balloons were randomly selected from prostate patients treated with proton therapy at University of Florida Proton Therapy Institute (Jacksonville, FL). Their pretreatment and post-treatment orthogonal radiographs were analyzed, and both pretreatment setup residual error and intrafraction-motion data were obtained. Population histograms of intrafraction motion were plotted for both types of balloons. Population planning target-volume (PTV) margins were calculated with the van Herk formula of 2.5{Sigma}+ 0.7{sigma} to account for setup residual errors and intrafraction motion errors. Results: Pretreatment and post-treatment radiographs indicated that the use of gas-release rectal balloons reduced prostate intrafraction motion along superior-inferior (SI) and anterior-posterior (AP) directions. Similar patient setup residual errors were exhibited for both types of balloons. Gas-release rectal balloons resulted in PTV margin reductions from 3.9 to 2.8 mm in the SI direction, 3.1 to 1.8 mm in the AP direction, and an increase from 1.9 to 2.1 mm in the left-right direction. Conclusions: Prostate intrafraction motion is an important uncertainty source in radiotherapy after image-guided patient setup with online corrections. Compared to non-gas-release rectal balloons, gas-release balloons can reduce prostate intrafraction motion in the SI and AP directions caused by gas buildup.

  18. New concepts for interplanetary balloons and blimps, particularly for Titan

    Science.gov (United States)

    Nott, J.

    This paper proposes novel approaches for balloons for planets Titan BALLUTE A balloon or blimp arriving at a planet or moon with an atmosphere might inflate falling under a parachute or after landing Neither is ideal In both cases the envelope must include qualities needed for inflation as well as those for flight A ballute BALLoon parachUTE could be used thus a ballute is like a hot air balloon with a large mouth Initially it fills by ram pressure descending through an atmosphere As proposed it would then be heated by solid propellant It would stop descending and float level with hot air lift It is now a perfect location for inflation without wind or movement through the atmosphere and away from the uncertainties of the surface A ballute could be used over several bodies in the solar system BALLOONS FOR LOW TEMPERATURES Flight in very low temperatures is also discussed Conditions are so different that it is useful to examine basic factors These apply for any planet with low temperature and weather calm enough for balloons or blimps First for terrestrial hot air balloons thermal radiation is usually the dominant way heat is lost But radiation rises with the 4th power of absolute temperature At Titan radiation will be one or two orders of magnitude smaller Also the dense atmosphere allows small balloons small temperature differences So convection is small It appears a hot air balloon can easily be heated by a radioactive source likely carried to make electricity Pinholes are not important in such a balloon

  19. Ballooning modes or Fourier modes in a toroidal plasma?

    International Nuclear Information System (INIS)

    Connor, J.W.; Taylor, J.B.

    1987-01-01

    The relationship between two different descriptions of eigenmodes in a torus is investigated. In one the eigenmodes are similar to Fourier modes in a cylinder and are highly localized near a particular rational surface. In the other they are the so-called ballooning modes that extend over many rational surfaces. Using a model that represents both drift waves and resistive interchanges the transition from one of these structures to the other is investigated. In this simplified model the transition depends on a single parameter which embodies the competition between toroidal coupling of Fourier modes (which enhances ballooning) and variation in frequency of Fourier modes from one rational surface to another (which diminishes ballooning). As the coupling is increased each Fourier mode acquires a sideband on an adjacent rational surface and these sidebands then expand across the radius to form the extended mode described by the conventional ballooning mode approximation. This analysis shows that the ballooning approximation is appropriate for drift waves in a tokamak but not for resistive interchanges in a pinch. In the latter the conventional ballooning effect is negligible but they may nevertheless show a ballooning feature. This is localized near the same rational surface as the primary Fourier mode and so does not lead to a radially extended structure

  20. Aviation investigation report : hard landing : fuel leak and fire[Sundance Balloons International Firefly 12B (hot air balloon) C-FNVM, Winnipeg, Manitoba, 15 nm NE, 11 August 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-08-15

    This investigation report discussed an incident in Winnipeg in which a hot air balloon attempting to land during strong winds was dragged on its side for approximately 700 feet. The balloon's burners struck the ground as the balloon came to a stop, after which a propane leak occurred. An intense, uncontrolled fire ensued as balloon passengers were exiting from the partially-inverted basket. The pilot and 2 passengers suffered serious injuries, while another 4 passengers suffered minor injuries. The balloon's 2 propane tanks and a fire extinguisher canister exploded during the fire, which destroyed the balloon's basket. The rigging of the balloon was examined and no failures were discovered. Pressure tests showed that the balloon's hoses started leaking at the crimped sleeve fittings at 150 psi. While the pilot had been informed of potentially heavy winds and thunderstorms, changes in wind speed and direction occurred earlier than the forecasted time of 10:00. It was concluded that standards are needed to ensure balloon cabin safety. Balloon operators do not currently require the use of protective helmets or gloves in case of dragged landings. A review will be conducted to address the issue of proposed emergency fuel shut-offs for balloons carrying fare-paying passengers. 2 figs.

  1. Postural stability and occlusal status among Japanese elderly.

    Science.gov (United States)

    Song-Yu, Xuan; Rodis, Omar M M; Ogata, Sagiri; Can-Hu, Jin; Nishimura, Michiko; Matsumura, Seishi

    2012-06-01

    There are still no data available on the relationship between postural stability and occlusal status among the elderly. To examine relationships between postural stability and occlusal status through a cohort study among elderly Japanese. Oral examination, occlusal status, postural stability and a questionnaire were conducted and given to 87 community-dwelling Japanese at enrolment. The average occlusal pressure of the female group was statistically higher than the male group while average occlusal pressure and postural stability length were lesser in the group with more remaining teeth. Postural stability area and number of remaining teeth showed statistically significant correlations. Postural stability length was lesser in the group with strong occlusal force. Furthermore, the number of decayed teeth was fewer in the good hygiene group. This study identified a close relationship between occlusal status and postural stability of Japanese older individuals. Occlusal hypofunction was observed more in those with occlusal problems, and a decrease in their occlusal functions resulted in postural instability. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  2. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  3. Balloon catheter dilation of benign esophageal stenosis in children

    International Nuclear Information System (INIS)

    Fan Guoping; Yu Juming; Zhong Weixing; Zhu Ming; Wu Yeming; Shi Chengren

    2001-01-01

    Objective: To evaluate the methods and effect of balloon catheter dilation of benign esophageal stenosis in children. Methods: 9 cases had an anastomotic stenosis after surgical correction of esophageal atresia; 11 cases of esophageal stenosis due to ingestion of caustics; one case had an lower esophageal stenosis after Nissen surgery and one case after gastro-esophagoplasty. Age ranged from 17 days to 7 years. Each case had a barium esophagram before balloon dilation. The balloon size varied from 3 to 10 mm in diameter. Results: 21 cases were successful after dilation of balloon catheter. There were no esophageal perforation and complications. The satisfactory results maintained from six months to thirty months. Conclusions: Balloon catheter dilation is a simple, safe and reliable method for the treatment of benign esophageal strictures in children as the first choice

  4. Static and quasi-static analysis of lobed-pumpkin balloon

    Science.gov (United States)

    Nakashino, Kyoichi; Sasaki, Makoto; Hashimoto, Satoshi; Saito, Yoshitaka; Izutsu, Naoki

    The present study is motivated by the need to improve design methodology for super pressure balloon with 3D gore design concept, currently being developed at the Scientific Balloon Center of ISAS/JAXA. The distinctive feature of the 3-D gore design is that the balloon film has excess materials not only in the circumferential direction but also in the meridional direction; the meridional excess is gained by attaching the film boundaries to the corresponding tendons of a shorter length with a controlled shortening rate. The resulting balloon shape is a pumpkin-like shape with large bulges formed between adjacent tendons. The balloon film, when fully inflated, develops wrinkles in the circumferential direction over its entire region, so that the stresses in the film are limited to a small amount of uniaxial tension in the circumferential direction while the high meridional loads are carried by re-enforced tendons. Naturally, the amount of wrinkling in the film is dominated by the shortening rate between the film boundaries and the tendon curve. In the 3-D gore design, as a consequence, the shortening rate becomes a fundamental design parameter along with the geometric parameters of the gore. In view of this, we have carried out a series of numerical study of the lobed-pumpkin balloon with varying gore geometry as well as with varying shortening rate. The numerical simula-tions were carried out with a nonlinear finite element code incorporating the wrinkling effect. Numerical results show that there is a threshold value for the shortening rate beyond which the stresses in the balloon film increases disproportionately. We have also carried out quasi-static simulations of the inflation process of the lobed-pumpkin balloon, and have obtained asymmetric deformations when the balloon films are in uniaxial tension state.

  5. An Overview of Current and Future Stratospheric Balloon Mission Capabilities

    Science.gov (United States)

    Smith, Michael

    The modern stratospheric balloon has been used for a variety of missions since the late 1940's. Capabilities of these vehicles to carry larger payloads, fly to higher altitudes, and fly for longer periods of time have increased dramatically over this time. In addition to these basic performance metrics, reliability statistics for balloons have reached unprecedented levels in recent years. Balloon technology developed in the United States in the last decade has the potential to open a new era in economical space science using balloons. As always, the advantage of the balloon platform is the fact that missions can be carried out at a fraction of the cost and schedule of orbital missions. A secondary advantage is the fact that instruments can be re-flown numerous times while upgrading sensor and data processing technologies from year to year. New mission capabilities now have the potential for enabling ground breaking observations using balloons as the primary platform as opposed to a stepping stone to eventual orbital observatories. The limit of very high altitude balloon missions will be explored with respect to the current state of the art of balloon materials and fabrication. The same technological enablers will also be applied to possibilities for long duration missions at mid latitudes with payloads of several tons. The balloon types and their corresponding mission profiles will be presented in a performance matrix that will be useful for potential scientific users in planning future research programs.

  6. An analysis of the deployment of a pumpkin balloon at Mars

    Science.gov (United States)

    Rand, J. L.; Phillips, M. L.

    2004-01-01

    The design of large superpressure balloons has received significant attention in recent years due to the successful demonstration of various enabling technologies and materials. Of particular note is the "pumpkin" shaped balloon concept, which allows the stress in the envelope to be limited by the surface geometry. Unlike a sphere, where the radius used to determine the stress is determined by the volume of the balloon, the pumpkin utilizes a system of meridional tendons to react the loading in one direction, and form a number of lobes, which limit the stress in the circumferential direction. A suitable superpressure balloon has been designed using this technology which will carry 2 kg in the atmosphere of Mars. The deployment of this balloon is assumed to occur while falling on a decelerator suitably designed for the Mars atmosphere. The inflation is accomplished by a 10 kg system suspended at the nadir of the balloon. As the system falls toward the surface of the planet, helium gas is transferred into the balloon, forming a partially inflated system very similar to an ascending zero pressure balloon. This analysis incorporates the flow of the planetary gas around the inflating balloon which alters the pressure distribution and shape. As a result, stresses are seen to increase beyond the design values which will require the balloon to be redesigned to accommodate this type of dynamic deployment.

  7. False coronary dissection with the new Monorail angioplasty balloon catheter.

    Science.gov (United States)

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  8. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1988-01-01

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  9. A new method of evaluating posterior occlusion and its relation to posttreatment occlusal changes.

    Science.gov (United States)

    Parkinson, C E; Buschang, P H; Behrents, R G; Throckmorton, G S; English, J D

    2001-11-01

    The purpose of this study was to assess the relationship between posterior occlusion and posttreatment changes in other occlusal variables. Pretreatment (T1), posttreatment (T2), and postretention (T3) records were obtained for 49 Class I (n = 23) and Class II (n = 26) extraction cases. Overbite, overjet, mandibular incisor irregularity, right and left molar deviations, midline deviation, and mandibular arch length were measured, and occlusal registrations were made of each set of dental casts. The proximity of posterior occlusal surfaces was measured as the contact or near-contact areas at or below 300 microm thickness, based on the optical densities of scanned images of the posterior occlusal registrations. The treatment changes for overbite, overjet, right and left molar deviation, and arch length were significantly greater in the Class II group, and the reductions in incisor irregularity were greater in the Class I group. No other class differences were found. Overbite, overjet, and incisor irregularity increased after treatment, and arch length continued to decrease, with no significant class differences. Contact and near-contact areas at or below 300 microm constituted 7% of the functional occlusal table for both classes at the end of treatment, having decreased significantly in both groups (21% in Class I and 29% in Class II) during treatment. Because contact and near-contact areas increased in some patients and decreased in others, there were no significant posttreatment changes. Negative correlations were found between contact and near-contact areas at T2 and changes in overjet from T2 to T3, and between contact and near-contact areas at T3 and changes in overbite from T2 to T3. No relationships were found between posterior contact and near-contact area and incisor irregularity. We concluded that (1) the area of actual and near contacts at or below 300 microm decreased significantly with treatment, indicating that, despite excellent treatment results by

  10. Influence of mandibular fixation method on stability of the maxillary occlusal plane after occlusal plane alteration.

    Science.gov (United States)

    Yosano, Akira; Katakura, Akira; Takaki, Takashi; Shibahara, Takahiko

    2009-05-01

    In this study, we investigated how method of mandibular fixation influenced longterm postoperative stability of the maxilla in Class III cases. In particular, we investigated change in the maxillary occlusal plane after Occlusal Plane Alteration. Therefore, we focused on change in the palatal plane to evaluate stability of the maxillary occlusal plane, as the position of the palatal plane affects the maxillary occlusal plane. This study included 16 patients diagnosed with mandibular protrusion. Alteration of the occlusal plane was achieved by clockwise rotation of the maxilla by Le Fort I osteotomy and mandibular setback was performed by bilateral sagittal split ramus osteotomy. We analyzed and examined lateral cephalometric radiographs taken at 1 month, 3 months, 6 months, and 1 year after surgery. Stability achieved by two methods of mandibular fixation was compared. In one group of patients (group S) titanium screws were used, and in the other group (group P) titanium-locking mini-plates were used. No significant displacement was recognized in group S, whereas an approximately 0.7mm upward vertical displacement was recognized in the anterior nasal spine in group P. As a result, not only the angle of the palatal plane and S-N plane, but also occlusal plane angle in group P showed a greater decrease than that in group S. The results suggest that fixing the mandible with screws yielded greater stability of the maxilla and maxillary occlusal plane than fixing the mandible with titanium plates.

  11. Numerical research on the thermal performance of high altitude scientific balloons

    International Nuclear Information System (INIS)

    Dai, Qiumin; Xing, Daoming; Fang, Xiande; Zhao, Yingjie

    2017-01-01

    Highlights: • A model is presented to evaluate the IR radiation between translucent surfaces. • Comprehensive ascent and thermal models of balloons are established. • The effect of IR transmissivity on film temperature distribution is unneglectable. • Atmospheric IR radiation is the primary thermal factor of balloons at night. • Solar radiation is the primary thermal factor of balloons during the day. - Abstract: Internal infrared (IR) radiation is an important factor that affects the thermal performance of high altitude balloons. The internal IR radiation is commonly neglected or treated as the IR radiation between opaque gray bodies. In this paper, a mathematical model which considers the IR transmissivity of the film is proposed to estimate the internal IR radiation. Comprehensive ascent and thermal models for high altitude scientific balloons are established. Based on the models, thermal characteristics of a NASA super pressure balloon are simulated. The effects of film IR property on the thermal behaviors of the balloon are discussed in detail. The results are helpful for the design and operation of high altitude scientific balloons.

  12. Occlusion Handling in Videos Object Tracking: A Survey

    International Nuclear Information System (INIS)

    Lee, B Y; Liew, L H; Cheah, W S; Wang, Y C

    2014-01-01

    Object tracking in video has been an active research since for decades. This interest is motivated by numerous applications, such as surveillance, human-computer interaction, and sports event monitoring. Many challenges related to tracking objects still remain, this can arise due to abrupt object motion, changing appearance patterns of objects and the scene, non-rigid object structures and most significant are occlusion of tracked object be it object-to-object or object-to-scene occlusions. Generally, occlusion in object tracking occur under three situations: self-occlusion, inter-object occlusion by background scene structure. Self-occlusion occurs most frequently while tracking articulated objects when one part of the object occludes another. Inter-object occlusion occurs when two objects being tracked occlude each other whereas occlusion by the background occurs when a structure in the background occludes the tracked objects. Typically, tracking methods handle occlusion by modelling the object motion using linear and non-linear dynamic models. The derived models will be used to continuously predicting the object location when a tracked object is occluded until the object reappears. Example of these method are Kalman filtering and Particle filtering trackers. Researchers have also utilised other features to resolved occlusion, for example, silhouette projections, colour histogram and optical flow. We will present some result from a previously conducted experiment when tracking single object using Kalman filter, Particle filter and Mean Shift trackers under various occlusion situation in this paper. We will also review various other occlusion handling methods that involved using multiple cameras. In a nutshell, the goal of this paper is to discuss in detail the problem of occlusion in object tracking and review the state of the art occlusion handling methods, classify them into different categories, and identify new trends. Moreover, we discuss the important

  13. Occlusion Handling in Videos Object Tracking: A Survey

    Science.gov (United States)

    Lee, B. Y.; Liew, L. H.; Cheah, W. S.; Wang, Y. C.

    2014-02-01

    Object tracking in video has been an active research since for decades. This interest is motivated by numerous applications, such as surveillance, human-computer interaction, and sports event monitoring. Many challenges related to tracking objects still remain, this can arise due to abrupt object motion, changing appearance patterns of objects and the scene, non-rigid object structures and most significant are occlusion of tracked object be it object-to-object or object-to-scene occlusions. Generally, occlusion in object tracking occur under three situations: self-occlusion, inter-object occlusion by background scene structure. Self-occlusion occurs most frequently while tracking articulated objects when one part of the object occludes another. Inter-object occlusion occurs when two objects being tracked occlude each other whereas occlusion by the background occurs when a structure in the background occludes the tracked objects. Typically, tracking methods handle occlusion by modelling the object motion using linear and non-linear dynamic models. The derived models will be used to continuously predicting the object location when a tracked object is occluded until the object reappears. Example of these method are Kalman filtering and Particle filtering trackers. Researchers have also utilised other features to resolved occlusion, for example, silhouette projections, colour histogram and optical flow. We will present some result from a previously conducted experiment when tracking single object using Kalman filter, Particle filter and Mean Shift trackers under various occlusion situation in this paper. We will also review various other occlusion handling methods that involved using multiple cameras. In a nutshell, the goal of this paper is to discuss in detail the problem of occlusion in object tracking and review the state of the art occlusion handling methods, classify them into different categories, and identify new trends. Moreover, we discuss the important

  14. Adjustable continence balloons

    DEFF Research Database (Denmark)

    Kjær, Line; Fode, Mikkel; Nørgaard, Nis

    2012-01-01

    Abstract Objective. This study aimed to evaluate the results of the Danish experience with the ProACT urinary continence device inserted in men with stress urinary incontinence. Material and methods. The ProACT was inserted in 114 patients. Data were registered prospectively. The main endpoints...... in urinary leakage > 50% was seen in 72 patients (80%). Complications were seen in 23 patients. All of these were treated successfully by removal of the device in the outpatient setting followed by replacement of the device. Another eight patients had a third balloon inserted to improve continence further....... Fourteen patients (12%) ended up with an artificial sphincter or a urethral sling. Sixty patients (63%) experienced no discomfort and 58 (61%) reported being dry or markedly improved. Overall, 50 patients (53%) reported being very or predominantly satisfied. Conclusions. Adjustable continence balloons seem...

  15. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio

    2014-01-01

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  16. Analysis of current diffusive ballooning mode

    International Nuclear Information System (INIS)

    Yagi, M.; Azumi, M.; Itoh, K.; Itoh, S.; Fukuyama, A.

    1993-04-01

    The current diffusive ballooning mode is analysed in the tokamak plasma. This mode is destabilized by the current diffusivity (i.e., the electron viscosity) and stabilized by the thermal conductivity and ion viscosity. By use of the ballooning transformation, the eigenmode equation is solved. Analytic solution is obtained by the strong ballooning limit. Numerical calculation is also performed to confirm the analytic theory. The growth rate of the mode and the mode structure are analysed. The stability boundary is derived in terms of the current diffusivity, thermal conductivity, ion viscosity and the pressure gradient for the given shear parameter. This result is applied to express the thermal conductivity in terms of the pressure gradient, magnetic configurational parameters (such as the safety factor, shear and aspect ratio) and the Prandtl numbers. (author)

  17. Design and evaluation of a continuum robot with extendable balloons

    Directory of Open Access Journals (Sweden)

    E. Y. Yarbasi

    2018-02-01

    Full Text Available This article presents the design and preliminary evaluation of a novel continuum robot actuated by two extendable balloons. Extendable balloons are utilized as the actuation mechanism of the robot, and they are attached to the tip from their slack sections. These balloons can extend very much in length without having a significant change in diameter. Employing two balloons in an axially extendable, radially rigid flexible shaft, radial strain becomes constricted, allowing high elongation. As inflated, the balloons apply a force on the wall of the tip, pushing it forward. This force enables the robot to move forward. The air is supplied to the balloons by an air compressor and its flow rate to each balloon can be independently controlled. Changing the air volumes differently in each balloon, when they are radially constricted, orients the robot, allowing navigation. Elongation and force generation capabilities and pressure data are measured for different balloons during inflation and deflation. Afterward, the robot is subjected to open field and maze-like environment navigation tests. The contribution of this study is the introduction of a novel actuation mechanism for soft robots to have extreme elongation (2000 % in order to be navigated in substantially long and narrow environments.

  18. Occlusion-Aware View Interpolation

    Directory of Open Access Journals (Sweden)

    Ince Serdar

    2008-01-01

    Full Text Available Abstract View interpolation is an essential step in content preparation for multiview 3D displays, free-viewpoint video, and multiview image/video compression. It is performed by establishing a correspondence among views, followed by interpolation using the corresponding intensities. However, occlusions pose a significant challenge, especially if few input images are available. In this paper, we identify challenges related to disparity estimation and view interpolation in presence of occlusions. We then propose an occlusion-aware intermediate view interpolation algorithm that uses four input images to handle the disappearing areas. The algorithm consists of three steps. First, all pixels in view to be computed are classified in terms of their visibility in the input images. Then, disparity for each pixel is estimated from different image pairs depending on the computed visibility map. Finally, luminance/color of each pixel is adaptively interpolated from an image pair selected by its visibility label. Extensive experimental results show striking improvements in interpolated image quality over occlusion-unaware interpolation from two images and very significant gains over occlusion-aware spline-based reconstruction from four images, both on synthetic and real images. Although improvements are obvious only in the vicinity of object boundaries, this should be useful in high-quality 3D applications, such as digital 3D cinema and ultra-high resolution multiview autostereoscopic displays, where distortions at depth discontinuities are highly objectionable, especially if they vary with viewpoint change.

  19. Occlusion-Aware View Interpolation

    Directory of Open Access Journals (Sweden)

    Janusz Konrad

    2009-01-01

    Full Text Available View interpolation is an essential step in content preparation for multiview 3D displays, free-viewpoint video, and multiview image/video compression. It is performed by establishing a correspondence among views, followed by interpolation using the corresponding intensities. However, occlusions pose a significant challenge, especially if few input images are available. In this paper, we identify challenges related to disparity estimation and view interpolation in presence of occlusions. We then propose an occlusion-aware intermediate view interpolation algorithm that uses four input images to handle the disappearing areas. The algorithm consists of three steps. First, all pixels in view to be computed are classified in terms of their visibility in the input images. Then, disparity for each pixel is estimated from different image pairs depending on the computed visibility map. Finally, luminance/color of each pixel is adaptively interpolated from an image pair selected by its visibility label. Extensive experimental results show striking improvements in interpolated image quality over occlusion-unaware interpolation from two images and very significant gains over occlusion-aware spline-based reconstruction from four images, both on synthetic and real images. Although improvements are obvious only in the vicinity of object boundaries, this should be useful in high-quality 3D applications, such as digital 3D cinema and ultra-high resolution multiview autostereoscopic displays, where distortions at depth discontinuities are highly objectionable, especially if they vary with viewpoint change.

  20. Dynamic myocardial perfusion in a porcine balloon-induced ischemia model using a prototype spectral detector CT

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Fares, Anas; Levi, Jacob; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2015-03-01

    Myocardial CT perfusion (CTP) imaging is an application that should greatly benefit from spectral CT through the significant reduction of beam hardening (BH) artifacts using mono-energetic (monoE) image reconstructions. We used a prototype spectral detector CT (SDCT) scanner (Philips Healthcare) and developed advanced processing tools (registration, segmentation, and deconvolution-based flow estimation) for quantitative myocardial CTP in a porcine ischemia model with different degrees of coronary occlusion using a balloon catheter. The occlusion severity was adjusted with fractional flow reserve (FFR) measurements. The SDCT scanner is a single source, dual-layer detector system, which allows simultaneous acquisitions of low and high energy projections, hence enabling accurate projection-based material decomposition and effective reduction of BH-artifacts. In addition, the SDCT scanner eliminates partial scan artifacts with fast (0.27s), full gantry rotation acquisitions. We acquired CTP data under different hemodynamic conditions and reconstructed conventional 120kVp images and projection-based monoenergetic (monoE) images for energies ranging from 55keV-to-120keV. We computed and compared myocardial blood flow (MBF) between different reconstructions. With balloon completely deflated (FFR=1), we compared the mean attenuation in a myocardial region of interest before iodine arrival and at peak iodine enhancement in the left ventricle (LV), and we found that monoE images at 70keV effectively minimized the difference in attenuation, due to BH, to less than 1 HU compared to 14 HU with conventional 120kVp images. Flow maps under baseline condition (FFR=1) were more uniform throughout the myocardial wall at 70keV, whereas with 120kVp data about 12% reduction in blood flow was noticed on BH-hypoattenuated areas compared to other myocardial regions. We compared MBF maps at different keVs under an ischemic condition (FFR < 0.7), and we found that flow

  1. Application of conjugated heparin-albumin microparticles with laser-balloon angioplasty: a potential method for reducing adverse biologic reactivity after angioplasty

    Science.gov (United States)

    Kundu, Sourav K.; McMath, Linda P.; Zaidan, Jonathan T.; Spears, J. Richard

    1991-05-01

    Laser-balloon angioplasty (LBA) may potentially be used for local application of pharmacologically active agents which will reduce thrombogenic and proliferative responses after the angioplasty. In this study, the feasibility of applying covalently conjugated heparin- albumin microparticles onto arterial luminal surface was demonstrated. The covalent linkages were formed by reaction with 1-ethyl-3-dimethyl-aminopropyl-carbodiimide (EDC), and the resultant conjugates were used for preparation of microparticles by employing standard emulsification and heat-crosslinking techniques. The heparin release rate from the microparticles was found to be dependent upon the degree of crosslinking. When a thin coagulum of a suspension of microparticles was formed with heat on a glass surface, the treated surface demonstrated resistance to clot formation in contact with non-anticoagulated blood. A suspension of the microparticles applied during laser-balloon angioplasty onto the luminal surface of dog carotid and femoral arteries showed persistence for up to one week without thrombus formation or occlusion of the vessel. Since the rate of biodegradation is primarily dictated by the extent of crosslinking, an optimal degree of thermal denaturation will permit longer persistence of the carrier while allowing adequate release of the entrapped pharmacologic agent. A variety of antithrombotic and antiinflammatory agents are being considered as candidate bioprotective materials for local application after angioplasty.

  2. Innovations in Balloon Catheter Technology in Rhinology.

    Science.gov (United States)

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Fluorescence Lyman-Alpha Stratospheric Hygrometer (FLASH): application on meteorological balloons, long duration balloons and unmanned aerial vehicles.

    Science.gov (United States)

    Lykov, Alexey; Khaykin, Sergey; Yushkov, Vladimir; Efremov, Denis; Formanyuk, Ivan; Astakhov, Valeriy

    The FLASH instrument is based on the fluorescent method, which uses H2O molecules photodissociation at a wavelength lambda=121.6 nm (Lalpha - hydrogen emission) followed by the measurement of the fluorescence of excited OH radicals. The source of Lyman-alpha radiation is a hydrogen discharge lamp while the detector of OH fluorescence at 308 -316 nm is a photomultiplier run in photon counting mode. The intensity of the fluorescent light as well as the instrument readings is directly proportional to the water vapor mixing ratio under stratospheric conditions with negligible oxygen absorption. Initially designed for rocket-borne application, FLASH has evolved into a light-weight balloon sonde (FLASH-B) for measurements in the upper troposphere and stratosphere on board meteorological and small plastic balloons. This configuration has been used in over 100 soundings at numerous tropical mid-latitude and polar locations within various international field campaigns. An airborne version of FLASH instrument is successfully utilized onboard stratospheric M55-Geophysica aircraft and tropospheric airborne laboratory YAK42-Roshydromet. The hygrometer was modified for application onboard stratospheric long-duration balloons (FLASH-LDB version). This version was successfully used onboard CNES super-pressure balloon launched from SSC Esrange in March 2007 and flown during 10 days. Special design for polar long duration balloon PoGOLite was created for testing work during polar day in June 2013. Installation and measurement peculiarities as well as observational results are presented. Observations of water vapour using FLASH-B instrument, being of high quality are rather costly as the payload recovery is often complicated and most of the time impossible. Following the goal to find a cost-efficient solution, FLASH was adapted for use onboard Unmanned Aerial Vehicles (UAV). This solution was only possible thanks to compactness and light-weight (0.5 kg) of FLASH instrument. The

  4. Rectal Balloon for the Immobilization of the Prostate Internal Motion

    International Nuclear Information System (INIS)

    Lee, Sang Kyu; Beak, Jong Geal; Kim, Joo Ho; Jeon, Byong Chul; Cho, Jeong Hee; Kim, Dong Wook; Song, Tae Soo; Cho, Jae Ho; Na, Soo Kyong

    2005-01-01

    The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning same repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal balloon position and verified the isodose distribution of rectum wall at closed prostate. Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficient for treated prostate cancer patients.

  5. Application of photogrammetry for analysis of occlusal contacts.

    Science.gov (United States)

    Shigeta, Yuko; Hirabayashi, Rio; Ikawa, Tomoko; Kihara, Takuya; Ando, Eriko; Hirai, Shinya; Fukushima, Shunji; Ogawa, Takumi

    2013-04-01

    The conventional 2D-analysis methods for occlusal contacts provided limited information on tooth morphology. This present study aims to detect 3D positional information of occlusal contacts from 2D-photos via photogrammetry. We propose an image processing solution for analysis of occlusal contacts and facets via the black silicone method and a photogrammetric technique. The occlusal facets were reconstructed from a 2D-photograph data-set of inter-occlusal records into a 3D image via photogrammetry. The configuration of the occlusal surface was reproduced with polygons. In addition, the textures of the occlusal contacts were mapped to each polygon. DIFFERENCE FROM CONVENTIONAL METHODS: Constructing occlusal facets with 3D polygons from 2D-photos with photogrammetry was a defining characteristic of this image processing technique. It allowed us to better observe findings of the black silicone method. Compared with conventional 3D analysis using a 3D scanner, our 3D models did not reproduce the detail of the anatomical configuration. However, by merging the findings of the inter-occlusal record, the deformation of mandible and the displacement of periodontal ligaments under occlusal force were reflected in our model. EFFECT OR PERFORMANCE: Through the use of polygons in the conversion of 2D images to 3D images, we were able to define the relation between the location and direction of the occlusal contacts and facets, which was difficult to detect via conventional methods. Through our method of making a 3D polygon model, the findings of inter-occlusal records which reflected the jaw/teeth behavior under occlusal force could be observed 3-dimensionally. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Development of radioactive 166Ho-coated balloon and its dose estimation

    International Nuclear Information System (INIS)

    Park, K. B.; Kim, K. H.; Hong, Y. D.; Park, E. W.

    2000-01-01

    The use of balloon with radioisotope is a promising method to prevent restenosis after transluminal coronary arterial angioplasty or stent implantation. In this study, we have developed a new radioactive coated balloon, which is prepared by coating the surface of existing balloon with 166 Ho instead of being filled with beta sources which emit high energy beta-particles for the purpose of the delivery of sufficient radiation to the vessel wall. To estimate the safety of 166 Ho-coated balloon, leaching test and radiation resistance test of the balloon were performed. The absorbed dose distributions around the 166 Ho-coated balloon were estimated by means of Monte Carlo simulation and the initial activities for optimal therapeutic regimen were determined on the basis of this results

  7. Current possibilities in occlusal caries management

    Directory of Open Access Journals (Sweden)

    Hrvoje Jurić

    2013-11-01

    Full Text Available Dental caries is a multifactorial disease that affects most populations throughout the world and it is still the primary cause of oral pain and tooth loss. The occlusal surfaces of posterior teeth are the most vulnerable sites for dental caries due to their anatomy. Therefore, the aim of the following article is to summarize current knowledge on occlusal caries development and the possibilities of its prevention. Although the overall caries rate today has fallen for populations in industrialized countries, the rate of occlusal surface caries has not decreased. This may be explained with fact that topically applied fluorides and their mode of action prevent caries better on smooth than on occlusal surfaces. As we know, tooth decay of first permanent molars causes a great deal of different short and long term difficulties for patients. Therefore, there is a continuous need for implementation of programs for caries prevention in permanent teeth. Nowadays, we like to treat our patients by minimally invasive methods. A very important step in our effective preventive treatment is sealing pits and fissures as a cornerstone of occlusal caries management. Reliable assessment of caries activity is also very important for defining treatment needs and plans. A very important decision, which should be made during occlusal caries management, is the selection of restorative material according to the treatment plan. Conclusion. Current possibilities in occlusal caries prevention and management are very effective. Therefore, dentists today do not have any excuse for avoiding the philosophy of Minimally Invasive Dentistry, especially when we talk about caries management of occlusal surfaces in permanent molars.

  8. Occlusion of Heubner's artery

    International Nuclear Information System (INIS)

    Sato, Manabu; Kidooka, Minoru

    1982-01-01

    A case of occlusion of the left Heubner's artery in a right-handed, 51-year-old man is reported. Cardinal clinical features were transient right hemiparesis and mental disturbance, especially intellectual defect. Low density areas were found at CT in the globus pallidus, putamen, anterior limb of the internal capsule and a part of the caudate nucleus. It is well known that the occlusion of the Heubner's artery causes transient motor paresis of upper extremity on the contralaterl side. However, in the case where the Heubner's artery is remarkably well developed when compared with the medial striate arteries as was the case in this patient, it should be noted that the occlusion of the Heubner's artery may well causes grave mental disturbance, in addition. (author)

  9. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  10. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    Directory of Open Access Journals (Sweden)

    Chiwata Ichiro

    2010-03-01

    Full Text Available Abstract Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs. However, a recent report described a discrepancy between the habitual occlusal position (HOP and the bite plate-induced occlusal position (BPOP and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI and the Helkimo Clinical Dysfunction Index (CDI before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p 0.1. Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted.

  11. Gastric emptying and intragastric balloon in obese patients.

    Science.gov (United States)

    Bonazzi, P; Petrelli, M D; Lorenzini, I; Peruzzi, E; Nicolai, A; Galeazzi, R

    2005-01-01

    Intragastric balloons have been proposed to induce weight loss in obese subjects. The consequences of the balloon on gastric physiology remain poorly studied. We studied the influence of an intragastric balloon on gastric emptying in obese patients. 12 patients were included in the study, with BMI (mean +/- SD) of 38.51 +/- 4.32 kg/m2. The balloon was inserted under light anaesthesia and endoscopic control, inflated with 700 ml saline, and removed 6 months later. Body weight and gastric emptying (T1/2 and T lag) using 13C-octanoic acid breath test were monitored before balloon placement, during its permanence and 2 months after removal. Mean weight loss was: 6.2 +/- 2.3 kg after one month; 12.4 +/- 5.8 kg after 3 months; 14.4 +/- 6.6 kg after 6 months and 10.1 +/- 4.3 kg two months after BIB removal. Gastric emptying rates were significantly decreased in the first periods with balloon in place, and returned to pre-implantation values after balloon removal. T1/2 was: 87 +/- 32 min before BIB positioning, 181 +/- 91 min after 1 month, 145 +/- 99 min after 3 months, 104 +/- 50 min after 6 months and 90 +/- 43 min 2 months after removal. T lag was 36 +/- 18 min before BIB positioning, 102 +/- 82 min after 1 month, 77 +/- 53 min after 3 months, 59 +/- 28 min after 6 months and 40 +/- 21 min. 2 months after removal. BIB in obese patients seems to be a good help in following the hypo caloric diet, especially during the first three months when the gastric emptying is slower and the sense of repletion is higher. After this period gastric emptying starts to return to normal and the stomach adapts to BIB loosing efficacy in weight loss.

  12. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1994-12-15

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study.

  13. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    International Nuclear Information System (INIS)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon

    1994-01-01

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study

  14. [Clinical application of ultrasound guided Fogarty balloon catheter in arterial crisis].

    Science.gov (United States)

    Li, Xiaodong; Wang, Pei; Yu, Changyu; Yan, Xiaowei; Yin, Jing

    2017-10-01

    To explore the effectiveness of arterial crisis after replantation of limb treated by ultrasound guided Fogarty balloon catheter. Between January 2012 and July 2016, 27 patients suffered from arterial crisis after replantation of limb were treated with ultrasound guided Fogarty balloon catheter combined with thrombolytic anticoagulant. There were 18 males and 9 females with the age of 19-51 years (mean, 32 years). The limb mutilation position was at knee joint in 3 cases, lower limb in 9 cases, ankle joint in 6 cases, elbow joint in 2 cases, forearm in 4 cases, and wrist joint in 3 cases. The arterial crisis happened at 2.5-18 hours (mean, 7.5 hours) after limb replantation surgery. Color doppler ultrasonography was used to diagnose the arterial thrombosis, finally the anastomotic thrombosis were found in 16 cases, non-anastomotic thrombosis in 7 cases, and combined thrombosis in 4 cases. All the thrombosis were deteced in the arteries with the length of 0.8-3.9 cm. No complication such as vascular perforation, rupture, air embolism, thromboembolism, wound infection, or sepsis happened after operation. Arterial crisis occurred again in 3 cases at 1.5-13.5 hours after limb replantation and treated by arterial exploration, 1 case was treated successfully; 2 cases had arterial occlusion and partial necrosis of limb, and got amputation treatment at last. The rest 24 cases survived with the incision healing by first stage. In the 24 cases, 1 case suffered from acute myonephropathic metabolic syndrome and corrected after hemodialysis; 1 case suffered from acute liver functional damage and corrected by comprehensive treatment of internal medicine. The 24 patients were followed up 7-38 months (mean, 11 months). At last follow-up, blood supply of the limb was good with normal skin temperature and improved sense of feeling, activity, and swelling. According to Chinese Medical Association of hand surgery to the upper extremity function assessment standard, the results were

  15. Ballooning Stability of the Compact Quasiaxially Symmetric Stellarator

    International Nuclear Information System (INIS)

    Redi, M.H.; Canik, J.; Dewar, R.L.; Johnson, J.L.; Klasky, S.; Cooper, W.A.; Kerbichler, W.

    2001-01-01

    The magnetohydrodynamic (MHD) ballooning stability of a compact, quasiaxially symmetric stellarator (QAS), expected to achieve good stability and particle confinement is examined with a method that can lead to estimates of global stability. Making use of fully 3D, ideal-MHD stability codes, the QAS beta is predicted to be limited above 4% by ballooning and high-n kink modes. Here MHD stability is analyzed through the calculation and examination of the ballooning mode eigenvalue isosurfaces in the 3-space [s, alpha, theta(subscript ''k'')]; s is the edge normalized toroidal flux, alpha is the field line variable, and theta(subscript ''k'') is the perpendicular wave vector or ballooning parameter. Broken symmetry, i.e., deviations from axisymmetry, in the stellarator magnetic field geometry causes localization of the ballooning mode eigenfunction, with new types of nonsymmetric, eigenvalue isosurfaces in both the stable and unstable spectrum. The isosurfaces around the most unstable points i n parameter space (well above marginal) are topologically spherical. In such cases, attempts to use ray tracing to construct global ballooning modes lead to a k-space runaway. Introduction of a reflecting cutoff in k(perpendicular) to model numerical truncation or finite Larmor radius (FLR) yields chaotic ray paths ergodically filling the allowed phase space, indicating that the global spectrum must be described using the language of quantum chaos theory. However, the isosurface for marginal stability in the cases studied are found to have a more complex topology, making estimation of FLR stabilization more difficult

  16. Balloon dilatation of the prostatic urethra

    International Nuclear Information System (INIS)

    Lee, Yeon Soo; Shim, Hyung Jin; Cha, Kyung Soo; Hong, Ju Hee; Lim, Myung Ah; Kim, Cheol Soo

    1991-01-01

    We analyzed the result of transurethral balloon dilatation in 11 patients with benign prostatic hypertrophy. The procedures were performed under intravenous sedation and local anesthesia with double lumen balloon catheter at 4 atmosphere for 10 minutes. After dilatation, the prostatism symptom scores improved in 10 out of 11 patients and the mean diameter of the prostatic urethra significantly increased form 4.3 mm to 10.2 mm (ρ < 0.005). The procedures were successful not only in lateral lobe hypertrophy but also in median lobe hypertrophy of the prostate. Postdilatation MRI of 1 patient showed an intact prostatic capsule and no periprostatic hematoma. Complications did not develop except in 1 patient with mild hematuria and incontinence. These preliminary results suggest that transurethral balloon dilatation can be an effective and safe treatment modality for benign prostatic hypertrophy

  17. Wind-Driven Montgolfiere Balloons for Mars

    Science.gov (United States)

    Jones, Jack A.; Fairbrother, Debora; Lemieux, Aimee; Lachenmeier, Tim; Zubrin, Robert

    2005-01-01

    Solar Montgolfiere balloons, or solar-heated hot air balloons have been evaluated by use on Mars for about 5 years. In the past, JPL has developed thermal models that have been confirmed, as well as developed altitude control systems to allow the balloons to float over the landscape or carry ground sampling instrumentation. Pioneer Astronautics has developed and tested a landing system for Montgolfieres. JPL, together with GSSL. have successfully deployed small Montgolfieres (<15-m diameter) in the earth's stratosphere, where conditions are similar to a Mars deployment. Two larger Montgolfieres failed, however, and a series of larger scale Montgolfieres is now planned using stronger, more uniform polyethylene bilaminate, combined with stress-reducing ripstitch and reduced parachute deceleration velocities. This program, which is presently under way, is a joint effort between JPL, WFF, and GSSL, and is planned for completion in three years.

  18. Aerial Deployment and Inflation System for Mars Helium Balloons

    Science.gov (United States)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  19. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    Science.gov (United States)

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  20. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  1. Spectrum of ballooning instabilities in a stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, W A [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Singleton, D B [Australian National Univ., ANU Supercomputing Facility, Canberra (Australia); Dewar, R L [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1995-08-01

    The recent revival of interest in the application of the `ballooning formalism` to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs.

  2. Spectrum of ballooning instabilities in a stellarator

    International Nuclear Information System (INIS)

    Cooper, W.A.; Singleton, D.B.; Dewar, R.L.

    1995-08-01

    The recent revival of interest in the application of the 'ballooning formalism' to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs

  3. Effect of glove occlusion on the skin barrier

    DEFF Research Database (Denmark)

    Tiedemann, Daniel; Clausen, Maja Lisa; John, Swen Malthe

    2016-01-01

    that the negative effect of occlusion in itself is limited, and that only extensive and long-term occlusion will cause barrier impairment. However, studies investigating combined effect of occlusion and exposure to soaps/detergents indicate that occlusion significantly enhances the skin barrier damage caused...... by detergents/soaps in a dose-response fashion....

  4. A balloon-borne experiment to investigate the Martian magnetic field

    Science.gov (United States)

    Schwingenschuh, K.; Feldhofer, H.; Koren, W.; Jernej, I.; Stachel, M.; Riedler, W.; Slamanig, H.; Auster, H.-U.; Rustenbach, J.; Fornacon, H. K.; Schenk, H. J.; Hillenmaier, O.; Haerendel, G.; Yeroshenko, Ye.; Styashkin, V.; Zaroutzky, A.; Best, A.; Scholz, G.; Russell, C. T.; Means, J.; Pierce, D.; Luhmann, J. G.

    1996-03-01

    The Space Research Institute of the Austrian Academy, of Sciences (Graz, Austria) in cooperation with MPE (Berlin, Germany), GFZ Potsdam (Obs. Niemegk, Germany) IZMIRAN/IOFAN (Moscow, Russian) and IGPP/UCLA (Los Angeles, USA) is designing the magnetic field experiment MAGIBAL (MAGnetic field experiment aboard a martian BALloon) to investigate the magnetic field on the surface of Mars. The dual sensor fluxgate magnetometer is part of the MARS-98/MARS-TOGETHER balloon payload. During a ten days period the balloon will float over a distance of about 2000 km at altitudes between 0 and 4 km. Due to the limited power and telemetry allocation the magnetometer can transmit only one vector per ten seconds and spectral information in the frequency range from 2 - 25 Hz. The dynamic range is +/- 2000 nT. The main scientific objectives of the experiment are: • Determination of the magnetism of the Martian rocks • Investigation of the leakage of the solar wind induced magnetosphere using the correlation between orbiter and balloon observations • Measurement of the magnetic field profile between the orbiter and the surface of Mars during the descent phase of the balloon. Terrestrial test flights with a hot air balloon were performed in order to test the original MAGIBAL equipment under balloon flight conditions.

  5. Usefulness of cutting balloon angioplasty for the treatment of congenital heart defects.

    Science.gov (United States)

    Kusa, Jacek; Mazurak, Magdalena; Skierska, Agnieszka; Szydlowski, Leslaw; Czesniewicz, Pawel; Manka, Lukasz

    2018-01-01

    Patients with complex congenital heart defects may have different hemodynamic prob-lems which require a variety of interventional procedures including angioplasty which involves using high-pressure balloons. After failure of conventional balloon angioplasty, cutting balloon angioplasty is the next treatment option available. The purpose of this study was to evaluate the safety and efficacy of cutting balloon angioplasty in children with different types of congenital heart defects. Cutting balloon angioplasty was performed in 28 children with different congenital heart defects. The indication for cutting balloon angioplasty was: pulmonary artery stenosis in 17 patients, creating or dilatation of interatrial communication in 10 patients, and stenosis of left subclavian artery in 1 patient. In the pulmonary arteries group there was a significant decrease in systolic blood pressure (SBP) in the proximal part of the artery from the average 74.33 ± 20.4 mm Hg to 55 ± 16.7 mm Hg (p cutting balloon angioplasty was performed after an unsuccessful classic Rashkind procedure. After cutting balloon angioplasty there was a significant widening of the interatrial communication. Cutting balloon angioplasty is a feasible and effective treatment option in different con-genital heart defects.

  6. Knowledge of chronic total occlusion among Polish interventional cardiologists.

    Science.gov (United States)

    Bryniarski, Krzysztof L; Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Surowiec, Sławomir; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek

    2015-01-01

    Chronic total occlusion (CTO) recanalization is indicated in patients with symptoms and evidence of ischemia, but in most cases those types of lesions are still treated medically. In the last few years CTO angioplasty technique has changed dramatically due to considerable advances in techniques and dedicated equipment. An attempt to assess the state of knowledge of technical aspects of CTO angioplasty of coronary arteries among Polish interventional cardiologists. Questionnaire survey performed during two major Polish invasive cardiology workshops. In the study there participated 113 physicians with an average length of work experience of 13 years, most of them cardiologists certified as independent primary operators. The majority of respondents recognized the need of prevention of thrombotic complications through control of activated coagulation time during the CTO procedures. Prevention of renal complications and X-ray protection are also recognized as a significant part of the procedures. The benefits from the use of over-the-wire microcatheters and balloons, the proper choice of dedicated guidewires, contralateral injections and retrograde technique are underestimated. Despite satisfactory knowledge about indications and qualification for the CTO procedure, the awareness of procedural aspects (particularly the retrograde technique) as well as the dedicated CTO equipment among Polish interventional cardiologists is still insufficient.

  7. [High-frequency components of occlusal sound in sliding movement].

    Science.gov (United States)

    Nagai, K

    1990-03-01

    We postulated that high-frequency components of the occlusal sound occurring due to the characteristic vibration of teeth can be useful data for confirmation of the stability in occlusion, and studied the high-frequency components in the cases both of an experimental sliding movement and a normal occlusion. The results obtained were as follows. 1. A study on high-frequency components of the occlusal sound in an experimental sliding movement. 1) A study on wave type of the occlusal sound revealed one damped oscillation in an impact form and two in a slide form. 2) Spectrum analysis of the damped oscillation showed a similar spectrum pattern with a peak existing between 16KHz or more and 17KHz or less in both impact and slide cases. 2. A study on high-frequency components of the occlusal sound in a normal occlusion case. 1) The wave type in occlusal sound we have observed in a normal occlusion group and in a prosthetic or operative group was as follows: One damped oscillation shown in an impact form and two damped oscillation in a slide form which were the same as those shown in the case where an interference device was attached. 2) Duration of the sliding movement was short in a normal occlusion group, but was prolonged in a prosthetic or operative group. 3) The incidence of the wave type in occlusal sound was 56.7% in a prosthetic or operative group as compared to 87.8% in a normal occlusion group in an impact form. In contrast, the incidence was 43.3% in a prosthetic or operative group as compared to 12.2% in a normal occlusion group in a slide form. Such difference in the incidence between the wave types suggested that high-frequency components of occlusal sound can be an index for judgement of the stability in occlusion.

  8. Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study

    International Nuclear Information System (INIS)

    He, Xu; Shin, Ji Hoon; Kim, Hyo Cheol; Woo, Cheol Woong; Woo, Sung Ha; Choi, Won Chan; Kim, Jong Gyu; Lim, Jin Oh; Kim, Tae Hyung; Yoon, Chang Jin; Song, Ho Young; Kang, Wee Chang

    2005-01-01

    We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group II was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms (ρ < 0.001). A significant difference was also found between group III and IV for both phantoms (ρ < 0.001). The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body

  9. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Prabhudesai, V.; Mitra, K.; West, D. J.; Dean, M. R. E.

    2003-01-01

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome

  10. Stabilization of ballooning modes with sheared toroidal rotation

    International Nuclear Information System (INIS)

    Miller, R.L.; Waelbroeck, F.L.; Hassam, A.B.; Waltz, R.E.

    1995-01-01

    Stabilization of magnetohydrodynamic ballooning modes by sheared toroidal rotation is demonstrated using a shifted circle equilibrium model. A generalized ballooning mode representation is used to eliminate the fast Alfven wave, and an initial value code solves the resulting equations. The s-α diagram (magnetic shear versus pressure gradient) of ballooning mode theory is extended to include rotational shear. In the ballooning representation, the modes shift periodically along the field line to the next point of unfavorable curvature. The shift frequency (dΩ/dq, where Ω is the angular toroidal velocity and q is the safety factor) is proportional to the rotation shear and inversely proportional to the magnetic shear. Stability improves with increasing shift frequency and direct stable access to the second stability regime occurs when this frequency is approximately one-quarter to one-half the Alfven frequency, ω A =V A /qR. copyright 1995 American Institute of Physics

  11. Ozone profiles from tethered balloon measurements in an urban plume experiment

    Science.gov (United States)

    Youngbluth, O., Jr.; Storey, R. W.; Clendenin, C. G.; Jones, S.; Leighty, B.

    1981-01-01

    NASA Langley Research Center used two tethered balloon systems to measure ozone in the general area of Norfolk, Va. The large balloon system which has an altitude range of 1,500 meters was located at Wallops Island, Va., and the smaller balloon which has an altitude range of 900 meters was located at Chesapeake, Va. Each balloon system measured ozone, temperature, humidity, wind speed, and wind direction from ground to its maximum altitude. From these measurements and from the location of the balloon sites, areas of ozone generation and ozone transport may be inferred. The measurements which were taken during August 1979 are discussed as well as the measurement techniques.

  12. Under X-ray guidance stent implantation through retrograde popliteal artery puncturing for the treatment of superficial femoral artery occlusion: the initial results in nine cases

    International Nuclear Information System (INIS)

    He Xu; Gu Jianping; Lou Wensheng; Chen Liang; Chen Guoping; Su Haobo; Song Jinhua; Wang Tao; Xu Ke

    2011-01-01

    Objective: To discuss the application of retrograde popliteal artery puncturing under X-ray guidance in the interventional therapy for superficial femoral artery occlusion. Methods: Retrograde popliteal artery puncturing under X-ray guidance was carried out in nine patients with long-segment occlusion of superficial femoral artery as antegrade recanalization via femoral artery approach had failed in them. After retrograde route was successfully established, the balloon dilation and subsequent stent placement for occluded vessel were performed. Results: The technical success was obtained in all patients. The occluded superficial femoral arteries were reopened and the symptoms of intermittent claudication disappeared. No serious complications such as injuries of adjacent nerves or vessels occurred. The ankle-brachial index (ABI) increased from preoperative (0.38±0.13) to postoperative (0.92±0.11) with the difference being statistically significant (P<0.01). A follow-up period lasting for 2-16 months was conducted. Eleven months after the treatment, intermittent claudication recurred in one case, and CT angiography showed that the distal part of the stent was narrowed. The symptoms were improved after percutaneous transcatheter angioplasty was performed again. Conclusion: Retrograde popliteal artery puncturing under X-ray guidance is an effective and safe technique for the treatment of superficial femoral artery long-segment occlusion with stent placement, especially for patients in whom antegrade recanalization via femoral artery approach fails. (authors)

  13. Balloon-Borne Infrasound Detection of Energetic Bolide Events

    Science.gov (United States)

    Young, Eliot F.; Ballard, Courtney; Klein, Viliam; Bowman, Daniel; Boslough, Mark

    2016-10-01

    Infrasound is usually defined as sound waves below 20 Hz, the nominal limit of human hearing. Infrasound waves propagate over vast distances through the Earth's atmosphere: the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization) has 48 installed infrasound-sensing stations around the world to detect nuclear detonations and other disturbances. In February 2013, several CTBTO infrasound stations detected infrasound signals from a large bolide that exploded over Chelyabinsk, Russia. Some stations recorded signals that had circumnavigated the Earth, over a day after the original event. The goal of this project is to improve upon the sensitivity of the CTBTO network by putting microphones on small, long-duration super-pressure balloons, with the overarching goal of studying the small end of the NEO population by using the Earth's atmosphere as a witness plate.A balloon-borne infrasound sensor is expected to have two advantages over ground-based stations: a lack of wind noise and a concentration of infrasound energy in the "stratospheric duct" between roughly 5 - 50 km altitude. To test these advantages, we have built a small balloon payload with five calibrated microphones. We plan to fly this payload on a NASA high-altitude balloon from Ft Sumner, NM in August 2016. We have arranged for three large explosions to take place in Socorro, NM while the balloon is aloft to assess the sensitivity of balloon-borne vs. ground-based infrasound sensors. We will report on the results from this test flight and the prospects for detecting/characterizing small bolides in the stratosphere.

  14. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  15. The role of scientific ballooning for exploration of the magnetosphere

    International Nuclear Information System (INIS)

    Block, L.P.; Lazutin, L.L.; Riedler, W.

    1984-11-01

    The magnetosphere is explored in situ by satellites, but measurements near the low altitude magnetospheric boundary by rockets, balloons and groundbased instruments play a very significant role. The geomagnetic field provides a frame with anisotropic wave and particle propagation effects, enabling remote sensing of the distant magnetosphere by means of balloon-borne and groundbased instruments. Examples will be given of successful studies, with coordinated satellite and balloon observations, of substorm, pulsation and other phenomena propagating both along and across the geomagnetic field. Continued efforts with sophisticated balloon-borne instrumentations should contribute substantially to our understanding of magnetospheric physics. (Author)

  16. Montgolfiere balloon missions from Mars and Titan

    Science.gov (United States)

    Jones, Jack A.

    2005-01-01

    Montgolfieres, which are balloons that are filled with heated ambient atmospheric gas, appear promising for the exploration of Mars as well as of Saturn's moon, Titan. On Earth, Montgolfieres are also known as 'hot air balloons'. Commercial versions are typically heated by burning propane, although a number of radiant and solar-heated Montgolfieres have been flown on earth by CNES.

  17. Location and data collection for long stratospheric balloon flights

    Science.gov (United States)

    Malaterre, P.

    Stratospheric balloons capable of taking a 30 kg scientific payload to an altitude of 22 to 30 km for 1 month or more were developed. In-flight experiments were used to qualify the designs of a pumpkin shaped superpressure balloon and an infrared hot air balloon. Tracking of the flights (location and transmission of the parameters measured on board) was achieved using a telemetry gondola including an ARGOS beacon adapted for operation in the low temperatures encountered.

  18. Transmural coil embolization—alternative technique for management of arterial perforation during subintimal angioplasty

    Directory of Open Access Journals (Sweden)

    Karthikeyan Damodharan

    2016-01-01

    Full Text Available Subintimal angioplasty of lower limb arterial occlusion carries a relatively higher risk of vessel perforation compared to transluminal angioplasty. Vessel perforation is a potentially life threatening complication which requires prompt recognition and management. They are usually managed by endovascular techniques such as low-pressure balloon tamponade, covered stents, and coil embolization of the ruptured artery. We describe a technique of treating vessel perforation following balloon angioplasty. Patient developed a large perforation of the proximal superficial femoral artery (SFA after balloon inflation during subintimal angioplasty of complete SFA occlusion. Following failure of balloon tamponade in sealing the perforation, we successfully treated it by deploying an embolization coil at the site of perforation through the vessel wall followed by balloon tamponade. Our technique could be a useful relatively inexpensive alternative treatment option in the management of vessel perforation compared to covered stents.

  19. Euso-Balloon: A pathfinder mission for the JEM-EUSO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Osteria, Giuseppe, E-mail: osteria@na.infn.it [Istituto Nazionale di Fisica Nucleare Sezione di Napoli, Naples (Italy); Scotti, Valentina [Istituto Nazionale di Fisica Nucleare Sezione di Napoli, Naples (Italy); Università di Napoli Federico II, Dipartimento di Fisica, Naples (Italy)

    2013-12-21

    EUSO-Balloon is a pathfinder mission for JEM-EUSO, the near-UV telescope proposed to be installed on board the ISS in 2017. The main objective of this pathfinder mission is to perform a full scale end-to-end test of all the key technologies and instrumentation of JEM-EUSO detectors and to prove the entire detection chain. EUSO-Balloon will measure the atmospheric and terrestrial UV background components, in different observational modes, fundamental for the development of the simulations. Through a series of flights performed by the French Space Agency CNES, EUSO-Balloon also has the potential to detect Extensive Air Showers (EAS) from above. EUSO-Balloon will be mounted in an unpressurized gondola of a stratospheric balloon. We will describe the instrument and the electronic system which performs instrument control and data management in such a critical environment.

  20. 78 FR 18533 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Science.gov (United States)

    2013-03-27

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... Hot Air Balloons Ltd female ACME threaded hose connectors, part numbers HS6139 and HS6144, installed... follows: * * * * * (c) Applicability This AD applies to Lindstrand Hot Air Balloons Ltd female ACME...

  1. 77 FR 64763 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Science.gov (United States)

    2012-10-23

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... propose to adopt a new airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female... identified in this proposed AD, contact Lindstrand Hot Air Balloons Ltd., Maesbury Road, Oswestry, Shropshire...

  2. 78 FR 9785 - Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances

    Science.gov (United States)

    2013-02-12

    ... Airworthiness Directives; Lindstrand Hot Air Balloons Ltd Appliances AGENCY: Federal Aviation Administration... airworthiness directive (AD) for certain Lindstrand Hot Air Balloons Ltd female ACME threaded hose connectors...., Washington, DC 20590. For service information identified in this AD, contact Lindstrand Hot Air Balloons Ltd...

  3. Intrarectal pressures and balloon expulsion related to evacuation proctography.

    Science.gov (United States)

    Halligan, S; Thomas, J; Bartram, C

    1995-01-01

    Seventy four patients with constipation were examined by standard evacuation proctography and then attempted to expel a small, non-deformable rectal balloon, connected to a pressure transducer to measure intrarectal pressure. Simultaneous imaging related the intrarectal position of the balloon to rectal deformity. Inability to expel the balloon was associated proctographically with prolonged evacuation, incomplete evacuation, reduced anal canal diameter, and acute anorectal angulation during evacuation. The presence and size of rectocoele or intussusception was unrelated to voiding of paste or balloon. An independent linear combination of pelvic floor descent and evacuation time on proctography correctly predicted maximum intrarectal pressure in 74% of cases. No patient with both prolonged evacuation and reduced pelvic floor descent on proctography could void the balloon, as maximum intrarectal pressure was reduced in this group. A prolonged evacuation time on proctography, in combination with reduced pelvic floor descent, suggests defecatory disorder may be caused by inability to raise intrarectal pressure. A diagnosis of anismus should not be made on proctography solely on the basis of incomplete/prolonged evacuation, as this may simply reflect inadequate straining. PMID:7672656

  4. Neuromuscular dentistry: Occlusal diseases and posture.

    Science.gov (United States)

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture.

  5. Ballooning stability analysis of JET H-mode discharges

    International Nuclear Information System (INIS)

    O'Brien, D.P.; Galvao, R.; Keilhacker, M.; Lazzaro, E.; Watkins, M.L.

    1989-01-01

    Previous studies of the stability of a large aspect ratio model equilibrium to ideal MHD ballooning modes have shown that across the bulk of the plasma there exist two marginally stable values of the pressure gradient parameter α. These define an unstable zone which separates the first (small α) stable region from the second (large α) stable region. Close to the separatrix, however, the first and second regions can coalesce when the surface averaged current density, Λ, exceeds a critical value. The plasma in this region is then stable to ballooning modes at all values of the pressure gradient. In this paper we extend these results to JET H-mode equilibria using a finite aspect ratio ballooning formalism, and assess the relevance of ideal ballooning stability in these discharges. In particular we analyse shot 15894 at time 56 sec. which is 1.3 s into the H-phase. (author) 4 refs., 4 figs

  6. Time management in acute vertebrobasilar occlusion.

    Science.gov (United States)

    Kamper, Lars; Rybacki, Konrad; Mansour, Michael; Winkler, Sven B; Kempkes, Udo; Haage, Patrick

    2009-03-01

    Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in 77% of patients. The overall mortality was 55%. Major complications were intracranial hemorrhage and peripheral embolism. The time period from symptom onset to intervention showed a strong correlation with the postinterventional NIHSS as well as the patient's age, with the best results in a 4-h interval. Multivariate statistics revealed similarities among the patients. Evaluation of time management in acute VBO by multivariate statistics is a helpful tool for definition of similarities in this patient group. Similarly to the door-to-balloon time for acute coronary interventions, the chances for a good outcome depend on a short time interval between symptom onset and intervention. While the only manipulable time period starts with hospital admission, our results emphasize the necessity of efficient intrahospital workflow.

  7. Time Management in Acute Vertebrobasilar Occlusion

    International Nuclear Information System (INIS)

    Kamper, Lars; Rybacki, Konrad; Mansour, Michael; Winkler, Sven B.; Kempkes, Udo; Haage, Patrick

    2009-01-01

    Acute vertebrobasilar occlusion (VBO) is associated with a high risk of stroke and death. Although local thrombolysis may achieve recanalization and improve outcome, mortality is still between 35% and 75%. However, without recanalization the chance of a good outcome is extremely poor, with mortality rates of 80-90%. Early treatment is a fundamental factor, but detailed studies of the exact time management of the diagnostic and interventional workflow are still lacking. Data on 18 patients were retrospectively evaluated. Time periods between symptom onset, admission to hospital, time of diagnosis, and beginning of intervention were correlated with postinterventional neurological status. The Glasgow Coma Scale and National Institute of Health Stroke Scale (NIHSS) were used to examine patients before and after local thrombolysis. Additionally, multivariate statistics were applied to reveal similarities between patients with neurological improvement. Primary recanalization was achieved in 77% of patients. The overall mortality was 55%. Major complications were intracranial hemorrhage and peripheral embolism. The time period from symptom onset to intervention showed a strong correlation with the postinterventional NIHSS as well as the patient's age, with the best results in a 4-h interval. Multivariate statistics revealed similarities among the patients. Evaluation of time management in acute VBO by multivariate statistics is a helpful tool for definition of similarities in this patient group. Similarly to the door-to-balloon time for acute coronary interventions, the chances for a good outcome depend on a short time interval between symptom onset and intervention. While the only manipulable time period starts with hospital admission, our results emphasize the necessity of efficient intrahospital workflow.

  8. Epulis and pyogenic granuloma with occlusal interference

    Directory of Open Access Journals (Sweden)

    Widowati Witjaksono

    2005-06-01

    Full Text Available In dental clinic of Hospital University Science Malaysia (HUSM, there were cases with Localized Gingival Enlargement (LGE in the oral cavity with occlusal interference. In this study, three cases were observed. They were a 13 - year- old female with fibrous lge around 31 and 32 with occlusal interference in protrusive movement due to X bite, a 15 - year – old female with pyogenic granuloma near 11 & 21 with occlusal interference due to deep bite; and a 24 – year – old female who was eight months in pregnancy with pyogenic granuloma on the 34-35 and severe generalized pregnancy gingivitis with occlusal interference in centric occlusion and lateral movement. Clinical and histopathological diagnosis of the first case showed fibrous epulis, whereas the second and third cases disclosed pyogenic granuloma. Chronic trauma of the gingiva due to occlusal interference was assumed to be the cause of those LGE in case 1 and 2, while in case 3 poor oral hygiene and chronic trauma were assumed to be the etiologic factors.

  9. Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation.

    Science.gov (United States)

    Ghosh, Justin; Sepahpour, Ali; Chan, Kim H; Singarayar, Suresh; McGuire, Mark A

    2013-05-01

    Persistent phrenic nerve palsy is the most frequent complication of cryoballoon ablation for atrial fibrillation and can be disabling. To describe a technique-immediate balloon deflation (IBD)-for the prevention of persistent phrenic nerve palsy, provide data for its use, and describe in vitro simulations performed to investigate the effect of IBD on the atrium and pulmonary vein. Cryoballoon procedures for atrial fibrillation were analyzed retrospectively (n = 130). IBD was performed in patients developing phrenic nerve dysfunction (n = 22). In vitro simulations were performed by using phantoms. No adverse events occurred, and all patients recovered normal phrenic nerve function before leaving the procedure room. No patient developed persistent phrenic nerve palsy. The mean cryoablation time to onset of phrenic nerve dysfunction was 144 ± 64 seconds. Transient phrenic nerve dysfunction was seen more frequently with the 23-mm balloon than with the 28-mm balloon (11 of 39 cases vs 11 of 81 cases; P = .036). Balloon rewarming was faster following IBD. The time to return to 0 and 20° C was shorter in the IBD group (6.7 vs 8.9 seconds; P = .007 and 16.7 vs 37.6 seconds; Pphrenic nerve palsy. Simulations suggest that IBD is unlikely to damage the atrium or pulmonary vein. Copyright © 2013 Heart Rhythm Society. All rights reserved.

  10. Hot air balloon engine

    Energy Technology Data Exchange (ETDEWEB)

    Edmonds, Ian [Solartran Pty Ltd, 12 Lentara Street, Kenmore, Brisbane 4069 (Australia)

    2009-04-15

    This paper describes a solar powered reciprocating engine based on the use of a tethered hot air balloon fuelled by hot air from a glazed collector. The basic theory of the balloon engine is derived and used to predict the performance of engines in the 10 kW to 1 MW range. The engine can operate over several thousand metres altitude with thermal efficiencies higher than 5%. The engine thermal efficiency compares favorably with the efficiency of other engines, such as solar updraft towers, that also utilize the atmospheric temperature gradient but are limited by technical constraints to operate over a much lower altitude range. The increased efficiency allows the use of smaller area glazed collectors. Preliminary cost estimates suggest a lower $/W installation cost than equivalent power output tower engines. (author)

  11. Advanced Onboard Energy Storage Solution for Balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced Balloon Programs at NASA are looking for a potential 100 day missions at mid-altitudes. These balloons would be powered by solar panels to take advantage of...

  12. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  13. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.; Martin, Tobias; Grosset, A. V Pascal; Brownlee, Carson; Hollt, Thomas; Brown, Benjamin P.; Smith, Sean T.; Hansen, Charles D.

    2012-01-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  14. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  15. Magnetic Resonance Imaging of Transient Left Ventricular Apical Ballooning Related to Emotional Stress: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mu Sook; Choi, Byoung Wook; Choe, Kyu Ok; Chung, Namsik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-02-15

    Transient left ventricular apical ballooning is characterized by transient wall motion abnormalities involving the left ventricular apex and mid-ventricle in the absence of coronary arterial occlusion. A 66-year-old woman presented to the emergency department with chest pain that mimicked acute myocardial infarction. An aortogram showed akinesis from the mid to apical left ventricle with sparing of the basal segments. Four days later, she underwent MRI, which demonstrated characteristic apical contractile dysfunction, the same as the aortogram, without evidence of myocardial infarction on the MRI. Two weeks later, her symptoms were resolved and follow-up echocardiography showed normal ventricular function. We suggest that MRI might be an integrated imaging diagnostic tool for the diagnosis of this syndrome, which demonstrated characteristic apical contractile dysfunction with performing cine MRI, the absence of significant coronary artery stenosis with performing coronary MR angiography and the absence of myocardial infarction with performing contrast enhanced delayed MRI.

  16. Magnetic Resonance Imaging of Transient Left Ventricular Apical Ballooning Related to Emotional Stress: a Case Report

    International Nuclear Information System (INIS)

    Lee, Mu Sook; Choi, Byoung Wook; Choe, Kyu Ok; Chung, Namsik

    2007-01-01

    Transient left ventricular apical ballooning is characterized by transient wall motion abnormalities involving the left ventricular apex and mid-ventricle in the absence of coronary arterial occlusion. A 66-year-old woman presented to the emergency department with chest pain that mimicked acute myocardial infarction. An aortogram showed akinesis from the mid to apical left ventricle with sparing of the basal segments. Four days later, she underwent MRI, which demonstrated characteristic apical contractile dysfunction, the same as the aortogram, without evidence of myocardial infarction on the MRI. Two weeks later, her symptoms were resolved and follow-up echocardiography showed normal ventricular function. We suggest that MRI might be an integrated imaging diagnostic tool for the diagnosis of this syndrome, which demonstrated characteristic apical contractile dysfunction with performing cine MRI, the absence of significant coronary artery stenosis with performing coronary MR angiography and the absence of myocardial infarction with performing contrast enhanced delayed MRI

  17. Potential advantages of treatment of transplanted saphenous vein aorto-coronary artery bypass grafts with beta irradiation to prevent graft occlusion.

    Science.gov (United States)

    Smith, R G

    1997-01-01

    Intimal proliferation or Neointimal hyperplasia (NIH) is a vascular lesion that often arises in arteries after balloon angioplasty or other vessel wall injuries. FIH is a vascular lesion that develops in autologous saphenous vein grafts (SVG) after transplantation into the aorto-coronary circulation or the peripheral vascular circulation. FIH shares elements of smooth muscle migration, proliferation and fibrous tissue deposition in common with nibrointimal proliferation (NIH). Either NIH of a coronary artery or FIH of a SVG obstruct the vascular lumen and result in myocardial dysfunction. Local radiotherapy has been used for several decades to reduce the post-operative recurrence of the fibrovascular proliferations of pterygia and keloids. Similarly, in animal and human experiments, endovascular radiotherapy has been shown to reduce arterial smooth muscle proliferation. Consideration of the similarities of vascular smooth muscle cell proliferation in NIH and FIH leads one to suggest that endovascular beta irradiation can reduce FIH as well as it reduces NIH. The goal of such treatment is to achieve a clinically significant decrease in the morbidity and mortality resulting from SVG occlusions. The potential for large reduction of the consequences of SVG occlusion, the very large number of patients at risk, and the simplicity of the proposed intervention encourages prompt scientific evaluation of this technique.

  18. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  19. MHD simulation of high wavenumber ballooning-like modes in LHD

    International Nuclear Information System (INIS)

    Miura, H.; Nakajima, N.

    2008-10-01

    Dynamical growths of high-wavenumber ballooning modes are studied through full-3D nonlinear MHD simulations of the Large Helical Device. The growths of the ballooning modes are identified by studying the growth rates and the radial profiles of the Fourier coefficients of fluctuation variables. The mechanisms to weaken the growth of instability, such as the local fattening of the pressure and the energy release to the parallel kinetic energy, are found being insufficient to suppress the high-wavenumber ballooning modes. Consequently, the mean pressure profile is totally modified when the evolutions of the ballooning modes are saturated. The numerical results reveal that we need some mechanisms which do not originate from an ideal MHD to achieve a mild, saturated behaviors beyond the growths of unstable high ballooning modes in the helical device. The parallel heat conductivity is proposed as one of possible non-ideal mechanisms. (author)

  20. Ballooning Interest in Science.

    Science.gov (United States)

    Kim, Hy

    1992-01-01

    Presents an activity in which students construct model hot air balloons to introduce the concepts of convection current, the principles of Charles' gas law, and three-dimensional geometric shapes. Provides construction and launching instructions. (MDH)

  1. Exponential Growth of Nonlinear Ballooning Instability

    International Nuclear Information System (INIS)

    Zhu, P.; Hegna, C. C.; Sovinec, C. R.

    2009-01-01

    Recent ideal magnetohydrodynamic (MHD) theory predicts that a perturbation evolving from a linear ballooning instability will continue to grow exponentially in the intermediate nonlinear phase at the same linear growth rate. This prediction is confirmed in ideal MHD simulations. When the Lagrangian compression, a measure of the ballooning nonlinearity, becomes of the order of unity, the intermediate nonlinear phase is entered, during which the maximum plasma displacement amplitude as well as the total kinetic energy continues to grow exponentially at the rate of the corresponding linear phase.

  2. Biomechanics of occlusion--implications for oral rehabilitation.

    Science.gov (United States)

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. © 2015 John Wiley & Sons Ltd.

  3. Dental occlusion and temporomandibular disorders.

    Science.gov (United States)

    Stone, J Caitlin; Hannah, Andrew; Nagar, Nathan

    2017-10-27

    Data sourcesMedline, Scopus and Google Scholar.Study selectionTwo reviewers selected studies independently. English language clinical studies assessing the association between temporomandibular disorders (TMD) and features of dental occlusion were considered.Data extraction and synthesisStudy quality was assessed based on the Newcastle-Ottawa Scale (NOS) and a narrative synthesis was presented.ResultsIn all 25 studies (17 case-control, eight comparative) were included. Overall there was a high variability between occlusal features and TMD diagnosis. Findings were consistent with a lack of clinically relevant association between TMD and dental occlusion. Only two studies were associated with TMD in the majority (≥50%) of single variable analyses in patient populations. Only mediotrusive interferences are associated with TMD in the majority of multiple variable analyses.ConclusionsThe findings support the absence of a disease-specific association, there is no ground to hypothesise a major role for dental occlusion in the pathophysiology of TMDs. Dental clinicians are thus encouraged to move forward and abandon the old-fashioned gnathological paradig.

  4. An investigation of electrostatically deposited radionuclides on latex balloons

    International Nuclear Information System (INIS)

    Price, T.; Caly, A.

    2012-01-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  5. An investigation of electrostatically deposited radionuclides on latex balloons

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.; Caly, A., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2012-07-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  6. Cutting balloon and high-pressure balloon dilation for palliative treatment of congenital double-chambered right ventricle and primary infundibular stenosis in a Golden retriever dog.

    Science.gov (United States)

    Schober, Karsten E; Rhinehart, Jaylyn; Kohnken, Rebecca; Bonagura, John D

    2017-12-01

    Combined cutting balloon and high-pressure balloon dilation was performed in a dog with a double-chambered right ventricle and severe infundibular stenosis of the right ventricular outflow tract. The peak systolic pressure gradient across the stenosis decreased by 65% after dilation (from 187 mmHg before to 66 mmHg after) affirming the intervention as successful. However, early re-stenosis occurred within 3 months leading to exercise intolerance, exercise-induced syncope, and right-sided congestive heart failure. Cutting balloon followed by high-pressure balloon dilation provided temporary but not long-term relief of right ventricular obstruction in this dog. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A comparison of Selective Aortic Arch Perfusion and Resuscitative Endovascular Balloon Occlusion of the Aorta for the management of hemorrhage-induced traumatic cardiac arrest: A translational model in large swine.

    Directory of Open Access Journals (Sweden)

    Ed B G Barnard

    2017-07-01

    Full Text Available Survival rates remain low after hemorrhage-induced traumatic cardiac arrest (TCA. Noncompressible torso hemorrhage (NCTH is a major cause of potentially survivable trauma death. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA at the thoracic aorta (Zone 1 can limit subdiaphragmatic blood loss and allow for IV fluid resuscitation when intrinsic cardiac activity is still present. Selective Aortic Arch Perfusion (SAAP combines thoracic aortic balloon hemorrhage control with intra-aortic oxygenated perfusion to achieve return of spontaneous circulation (ROSC when cardiac arrest has occurred.Male Yorkshire Landrace cross swine (80.0 ± 6.0 kg underwent anesthesia, instrumentation for monitoring, and splenectomy. TCA was induced by laparoscopic liver lobe resection combined with arterial catheter blood withdrawal to achieve a sustained systolic blood pressure <10 mmHg, cardiac arrest. After 3 min of arrest, swine were allocated to one of three interventions: (1 REBOA plus 4 units of IV fresh whole blood (FWB, (2 SAAP with oxygenated lactated Ringer's (LR, 1,600 mL/2 min, or (3 SAAP with oxygenated FWB 1,600 mL/2 min. Primary endpoint was survival to the end of 60 min of resuscitation, a simulated prehospital phase. Thirty animals were allocated to 3 groups (10 per group-5 protocol exclusions resulted in a total of 35 animals being used. Baseline measurements and time to cardiac arrest were not different amongst groups. ROSC was achieved in 0/10 (0%, 95% CI 0.00-30.9 REBOA, 6/10 (60%, 95% CI 26.2-87.8 SAAP-LR and 10/10 (100%, 95% CI 69.2-100.0 SAAP-FWB animals, p < 0.001. Survival to end of simulated 60-minute prehospital resuscitation was 0/10 (0%, 95% CI 0.00-30.9 for REBOA, 1/10 (10%, 95% CI 0.25-44.5 for SAAP-LR and 9/10 (90%, 95% CI 55.5-99.7 for SAAP-FWB, p < 0.001. Total FWB infusion volume was similar for REBOA (2,452 ± 0 mL and SAAP-FWB (2,250 ± 594 mL. This study was undertaken in laboratory conditions, and as such may have

  8. Iridium: Global OTH data communications for high altitude scientific ballooning

    Science.gov (United States)

    Denney, A.

    While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several

  9. Endovascular diagnostics and treatment of stenosis, acute thrombosis and chronic occlusion of arteries and upper limbs

    International Nuclear Information System (INIS)

    Tonev, I.; Zechirov, B.; Stanoev, D.; Velikov, C.; Smilkova, D.

    2015-01-01

    involving the upper limbs. Unidentified heaviness in right forearm and pain in right elbow during physical activity. A difference in blood pressure of the two arms of 60 mm Hg was measured. During diagnostic angiography, an occlusion of Truncus brachiocephalicus was identified. Utilizing dual arterial access – through right radial artery and right femoral artery, revascularization of the occlusion was performed and normal blood flow in arteria subclavian and arteria carotis was recovered. Case 3: Revascularization of distal segment of arteria radialis in acute post-traumatic occlusion. M.I., 46 years old. Two hours before hospitalization, after manual labor, causing trauma to the tissue of the palm, the patient experienced sharp pain and bruising of the first, second and third fingers of the hand. Using echodoppler, a lack of blood flow to distal segment of arteria radialis was identified. After diagnostic angiography, the artery was revascularized through balloon dilatation. Clinical symptoms disappear immediately after the revascularization

  10. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  11. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    Pretolesi, F.; Derchi, L.E.; Redaelli, G.; Papagni, L.

    2001-01-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  12. Ballooning-mirror instability and internally driven Pc 4--5 wave events

    International Nuclear Information System (INIS)

    Cheng, C.Z.; Qian, Q.; Takahashi, K.; Lui, A.T.Y.

    1994-03-01

    A kinetic-MHD field-aligned eigenmode stability analysis of low frequency ballooning-mirror instabilities has been performed for anisotropic pressure plasma sin the magnetosphere. The ballooning mode is mainly a transverse wave driven unstable by pressure gradient in the bad curvature region. The mirror mode with a dominant compressional magnetic field perturbation is excited when the product of plasma beta and pressure anisotropy (P perpendicular /P parallel > 1) is large. From the AMPTE/CCE particle and magnetic field data observed during Pc 4--5 wave events the authors compute the ballooning-mirror instability parameters and perform a correlation study with the theoretical instability threshold. They find that compressional Pc 5 waves approximately satisfy the ballooning-mirror instability condition, and transverse Pc 4--5 waves are probably related to resonant ballooning instabilities with small pressure anisotropy

  13. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  14. Fluoroscopy-guided balloon dilation in patients with Eustachian tube dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho-Young [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Park, Hong Ju; Kang, Woo Seok [University of Ulsan College of Medicine, Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, Seoul (Korea, Republic of); Park, Jung-Hoon [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); University of Ulsan College of Medicine, Department of Biomedical Engineering Research Center, Asan Medical Center, Seoul (Korea, Republic of); Wang, Zhe [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Tianjin Medical University General Hospital, Department of Radiology (China)

    2018-03-15

    To prospectively evaluate the technical feasibility and safety of fluoroscopy-guided balloon dilation in patients with Eustachian tube (ET) dysfunction. Patients who could not do a Valsalva manoeuvre for more than 6 months and diagnosed with chronic otitis media or ET dysfunction were prospectively enrolled. A 0.035-in. guide wire and 6-mm long balloon catheter with a diameter of 2 mm were used to dilate the cartilaginous portion of the ET under fluoroscopic guidance. The balloon was inflated by manual injection twice for 1 min each time. Clinical outcomes were assessed by the patient's ability to perform a Valsalva manoeuvre, and symptoms were assessed using the 7-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) score. Balloon dilation was attempted in a total of ten adult patients from October 2016 to March 2017. Technical success was achieved in all procedures (10/10). Ninety percent (9/10) of the balloons were fully dilated without waist deformity. There were no major complications. All patients were able to perform a Valsalva manoeuvre at the time of their last visit and/or improvement of at least one ETDQ-7 score. Fluoroscopy-guided balloon dilation seems to be technically feasible and safe in the treatment of ET dysfunction. (orig.)

  15. Occlusion classifiers for picture rate conversion

    NARCIS (Netherlands)

    Bartels, C.L.L.; Haan, de G.; Rabbani, Majid

    2009-01-01

    Occlusion detection is an essential ingredient in high quality picture rate up-conversion and view interpolation applications. Many integrated approaches to occlusion detection and classification have been proposed, particularly in the stereo literature. However, due to their high complexity and

  16. Unconventional ballooning structures for toroidal drift waves

    International Nuclear Information System (INIS)

    Xie, Hua-sheng; Xiao, Yong

    2015-01-01

    With strong gradients in the pedestal of high confinement mode (H-mode) fusion plasmas, gyrokinetic simulations are carried out for the trapped electron and ion temperature gradient modes. A broad class of unconventional mode structures is found to localize at arbitrary poloidal positions or with multiple peaks. It is found that these unconventional ballooning structures are associated with different eigen states for the most unstable mode. At weak gradient (low confinement mode or L-mode), the most unstable mode is usually in the ground eigen state, which corresponds to a conventional ballooning mode structure peaking in the outboard mid-plane of tokamaks. However, at strong gradient (H-mode), the most unstable mode is usually not the ground eigen state and the ballooning mode structure becomes unconventional. This result implies that the pedestal of H-mode could have better confinement than L-mode

  17. Experimental examinations with a new percutaneously insertable, expandable vascular endoprosthesis

    International Nuclear Information System (INIS)

    Strecker, E.P.; Berg, G.; Weber, H.; Bohl, M.; Dietrich, B.; Freiburg Univ.; Karlsruhe Univ.

    1987-01-01

    Restenosis and occlusion are the most common reasons why transluminal balloon angioplasty may fail to provide long-term benefit. To prevent restonosis and occlusion of diseased arteries after angioplasty an arterial endoprosthesis has been developed which is positioned to the balloon of an angioplasty catheter and which consists of a stainless steel pliable and elastic tube. With the inflation of the balloon the endoprosthesis will dilate and give the arterial wall a new mechanical support. This new device has been implanted in 12 experimental dogs in arteries of different size and lumen. The longest patency rate of nine months was observed with the completely developed method. (orig.) [de

  18. The development of coastal diffusion observation method with a captive balloon

    International Nuclear Information System (INIS)

    Fukuda, Masaaki; Yamada, Masaharu

    1980-03-01

    Apparatus whereby the dye cloud in a coastal area in diffusion experiment can be photographed was developed. It consists of a vinyl balloon two meters in diameter, a photographic device with the camera shutter released by wireless signals from the ground, and a winch to raise or lower the balloon. A maximum height of the balloon for taking photographs is 1000 m. During the single balloon flight, thirty photographs can be taken. With the balloon at a certain height, dye as the tracer in diffusion experiment is released at sea surface or a certain sea depth by dye-throwing means or pump, and then taking the photographs is started. Movement and diffusion of the dye are analyzed by means of the photographs taken. The apparatus is simple in mechanism and easy to transport. Dye experiment is possible in the surfe zone where a boat cannot enter. It is impossible, however, to raise the balloon in strong wind or sea breeze. Typical results of the dye diffusion experiment with the apparatus are given. (author)

  19. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    Science.gov (United States)

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  20. Operated DeBakey type III dissecting aortic aneurysm: review of 12 cases

    International Nuclear Information System (INIS)

    Moon, Hi Eun; Lee, Ghi Jai; Oh, Sang Joon; Yoon, Sei Ra; Shim, Jae Chan; Kim, Ho Kyun; Han, Chang Yul

    1995-01-01

    We evaluated the indications of operation and radiologic findings in 12 operated DeBakey type III aortic dissections. We retrospectively reviewed radiologic findings of 12 operated DeBakey type III aortic dissections, using CT, MRI, or aortography, and correlations were made with clinical course of the patients. Three cases were uncomplicated dissections. There were aneurysm rupture in 4 cases, impending rupture in 4 cases, occlusion of common iliac artery in 2 cases, occlusion of renal artery in 1 case, and compression of bronchus and esophagus by dilated aorta in 1 case. Associated clinical sign and symptoms were chest and back pain in 12 cases, claudication in 3 cases, dyspnea and dysphagia in 1 case, hoarseness in 1 case, and hemoptysis in 1 case. Post-operative complications were death from aneurysm rupture in 1 case, paraplegia in 2 cases, acute renal failure in 3 cases, and hemopericardium in 1 case. Although medical therapy is preferred in management of DeBakey type III aortic dissection, surgical treatment should be considered in patients with radiological findings of aortic rupture, impending rupture, occlusion of aortic major branches

  1. Hot air balloons fill gap in atmospheric and sensing platforms

    Science.gov (United States)

    Watson, Steven M.; Price, Russ

    Eric Edgerton was having a problem he could not solve: how to noninvasively collect in situ incinerator plume data. So he called in the Air Force and learned about its Atmospheric and Sensor Test Platform program; its platform is a manned hot air balloon. Many investigators are discovering the advantages of hot air balloons as stable, inexpensive platforms for performing in situ atmospheric measurements. Some are also using remote sensing capabilities on the balloon platforms.

  2. The role of "rescue saccades" in tracking objects through occlusions.

    Science.gov (United States)

    Zelinsky, Gregory J; Todor, Andrei

    2010-12-29

    We hypothesize that our ability to track objects through occlusions is mediated by timely assistance from gaze in the form of "rescue saccades"-eye movements to tracked objects that are in danger of being lost due to impending occlusion. Observers tracked 2-4 target sharks (out of 9) for 20 s as they swam through a rendered 3D underwater scene. Targets were either allowed to enter into occlusions (occlusion trials) or not (no occlusion trials). Tracking accuracy with 2-3 targets was ≥ 92% regardless of target occlusion but dropped to 74% on occlusion trials with four targets (no occlusion trials remained accurate; 83%). This pattern was mirrored in the frequency of rescue saccades. Rescue saccades accompanied approximatlely 50% of the Track 2-3 target occlusions, but only 34% of the Track 4 occlusions. Their frequency also decreased with increasing distance between a target and the nearest other object, suggesting that it is the potential for target confusion that summons a rescue saccade, not occlusion itself. These findings provide evidence for a tracking system that monitors for events that might cause track loss (e.g., occlusions) and requests help from the oculomotor system to resolve these momentary crises. As the number of crises increase with the number of targets, some requests for help go unsatisfied, resulting in degraded tracking.

  3. Catching Comet's Particles in the Earth's Atmosphere by Using Balloons

    Science.gov (United States)

    Potashko, Oleksandr; Viso, Michel

    The project is intended to catch cometary particles in the atmosphere by using balloons. The investigation is based upon knowledge that the Earth crosses the comet’s tails during the year. One can catch these particles at different altitudes in the atmosphere. So, we will be able to gradually advance in the ability to launch balloons from low to high altitudes and try to catch particles from different comet tails. The maximum altitude that we have to reach is 40 km. Both methods - distance observation and cometary samples from mission Stardust testify to the presence of organic components in comet’s particles. It would be useful to know more details about this organic matter for astrobiology; besides, the factor poses danger to the Earth. Moreover, it is important to prove that it is possible to get fundamental scientific results at low cost. In the last 5 years launching balloons has become popular and this movement looks like hackers’ one - as most of them occur without launch permission to airspace. The popularity of ballooning is connected with low cost of balloon, GPS unit, video recording unit. If you use iPhone, you have a light solution with GPS, video, picture and control function in one unit. The price of balloon itself begins from $50; it depends on maximum altitude, payload weight and material. Many university teams realized balloon launching and reached even stratosphere at an altitude of 33 km. But most of them take only video and picture. Meanwhile, it is possible to carry out scientific experiments by ballooning, for example to collect comet particles. There is rich experience at the moment of the use of mineral, chemical and isotopic analysis techniques and data of the comet’s dust after successful landing of StarDust capsule with samples in 2006. Besides, we may use absolutely perfect material to catch particles in the atmosphere, which was used by cosmic missions such as Stardust and Japanese Hayabusa. As to balloon launches, we could use

  4. Clinical Aspects of Combination of Ceramic and Acrylic Occlusal Surfaces

    Directory of Open Access Journals (Sweden)

    Z. Ozhohan

    2017-03-01

    Full Text Available The objective of the research was to develop and substantiate the methods of constructing the occlusal surfaces when manufacturing aesthetic fixed restorations through the combination of different materials. Materials and methods. The study included 65 patients with ceramic and acrylic occlusal surfaces of aesthetic fixed dental prostheses. Group I included 21 patients with a combination of ceramic and acrylic occlusal surfaces. Group II included 22 patients with a combination of ceramic occlusal surfaces. Group III included 22 patients with a combination of acrylic occlusal surfaces. The patients were observed 3, 6 and 12 months after prosthetic repair. Results. The greatest increase in the occlusal contact surface area of fixed restorations was observed in Group I, that is, when combining dental prostheses with ceramic and acrylic occlusal surfaces. Considering uneven abrasion of the occlusal surfaces, we do not recommend to combine different materials when veneering the occlusal surface of the antagonistic teeth. Conclusions. This study demonstrated the important role of the correct combination of materials when veneering the occlusal surfaces. Physical and chemical properties of materials, namely the abrasion resistance play a significant role in the long-term denture functioning. The smallest increase in the occlusal contact surface area was observed in Group II when combining ceramic occlusal surfaces. It was due to a good abrasion resistance of ceramics as compared to acrylic resin as well as the presence of the glazed layer which prevents the premature abrasion of the occlusal surfaces of the antagonistic teeth due to lower surface roughness. The combination of acrylic resin and ceramics when constructing the occlusal surfaces of fixed restorations in Group I demonstrated the highest rate of the increase in the occlusal contact surface area – 9.93%. It was due to a low hardness of acrylic resin and its high surface roughness. In

  5. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  6. The prevalence of questionable occlusal caries

    DEFF Research Database (Denmark)

    Makhija, Sonia K; Gilbert, Gregg H; Funkhouser, Ellen

    2012-01-01

    Questionable occlusal caries (QOC) can be defined as clinically suspected caries with no cavitation or radiographic evidence of occlusal caries. To the authors' knowledge, no one has quantified the prevalence of QOC, so this quantification was the authors' objective in conducting this study...

  7. Computed tomography in basilar artery occlusion in childhood

    International Nuclear Information System (INIS)

    Mori, Koreaki; Miwa, Soichi; Handa, Hajime

    1978-01-01

    A case of basilar artery occlusion in a 13-year-old boy is presented. Eighteen other cases of such occlusion in childhood in the relevant literature were analyzed, and then all nineteen cases were compared to adult cases. In comparison with adult cases, the following points were clear: (1) In children as well as in adults, basilar artery occlusion is more common in males. (2) As is well known, arteriosclerosis is the commonest cause in adults. In children, however, idiopathic and/or congenital occlusion are more common causes. (3) The main clinical manifestations in childhood as well as in maturity are consciousness disturbance, hemiplegia or quadriplegia, and pupillary abnormalities. (4) An occlusion of the proximal third of the basilar artery is common in adults, whereas an occlusion of the middle third is common in childhood. (5) Diagnosis is based on clinical manifestations, cerebral angiography, and computed tomography. (6) In contrast to the poor prognosis in adults, the prognosis is fairly in children. (author)

  8. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    Science.gov (United States)

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  9. Assessment of effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion using self-expanding Jaguar SM stents

    International Nuclear Information System (INIS)

    Kordecki, Kazimierz; Łukasiewicz, Adam; Nowicki, Mirosław; Lewszuk, Andrzej; Kowalewski, Radosław; Panek, Bogusław; Zawadzki, Michał; Michalak, Paweł; Gacko, Marek; Łebkowska, Urszula

    2012-01-01

    The goal of this work was to assess the effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion classified according to TASC using a self-expanding stent Jaguar SM. The study group included 95 patients (61 men and 34 women) who underwent treatment for stenosis or occlusion of lower limb arteries at the Department of Radiology of the University Hospital in Bialystok and the Diagnostic Radiology Department of the Central Clinical Hospital of the Ministry of Interior (MSWiA) in Warsaw between 2005 and 2007. All arterial lesions were of atherosclerotic etiology. The shortest stenotic fragment was 10 mm long and the longest occluded arterial fragment did not exceed 90 mm. Morphological classification of iliac artery lesions in treated patients was performed according to TASC II classification and included 10 patients with type A, 39 cases of type B, 36 with type C and 10 patients with type D lesions. Endovascular procedure failed to restore flow in five patients with TASC type D lesions, who were later referred for surgery. One patient suffered a complication – vessel perforation during predilatation, and had a stentgraft implanted. In 95% of patients stents were expanded using a balloon after implantation. Good results were achieved in practically all patients who underwent stent implantation. Patients were subjected to follow-up clinical and imaging evaluation during next 1–24 months. Success rate of the performed procedures as well as in a 30-day observation period was 100% in case of stenosis and 80% in case of vessel occlusion. A follow-up after 12 and 24 months showed patency of treated vessels in 84% and 76% of patients, respectively

  10. A study on occlusal stability in shortened dental arches.

    Science.gov (United States)

    Sarita, Paulo T N; Kreulen, Cees M; Witter, Dick J; van't Hof, Martin; Creugers, Nico H J

    2003-01-01

    The aim of this study was to verify the hypothesis that shortened dental arches constitute a risk to occlusal stability. Using cluster samples, 725 subjects with shortened dental arches comprising intact anterior regions and zero to eight occluding pairs of posterior teeth and 125 subjects with complete dental arches were selected. Subjects with shortened dental arches were classified into eight categories according to arch length and symmetry. Parameters for occlusal stability were interdental spacing, occlusal tooth wear, occlusal contact of incisors in intercuspal position, and vertical and horizontal overlap. Additionally, tooth mobility and overeruption of unopposed teeth were assessed. Influence of independent variables (dental arch category, age, gender, and residence) on the parameters for occlusal stability was assessed by one-way ANOVA and Tukey's multiple range tests. Extreme shortened dental arches (zero to two pairs of occluding premolars) had significantly more interdental spacing, occlusal contact of incisors, and vertical overlap compared to complete dental arches. Occlusal wear and prevalence of mobile teeth were highest in these categories. The category with three to four occluding premolars had significantly more interdental spacing and, for the older age group, more anterior teeth in occlusal contact compared to complete dental arches. Age was consistently associated with increased changes in occlusal integrity. Signs of increased risk to occlusal stability seemed to occur in extreme shortened dental arches, whereas no such evidence was found for intermediate categories of shortened dental arches.

  11. Detection of Artificially Generated Seismic Signals Using Balloon-Borne Infrasound Sensors

    Science.gov (United States)

    Krishnamoorthy, Siddharth; Komjathy, Attila; Pauken, Michael T.; Cutts, James A.; Garcia, Raphael F.; Mimoun, David; Cadu, Alexandre; Sournac, Anthony; Jackson, Jennifer M.; Lai, Voon Hui; Bowman, Daniel C.

    2018-04-01

    We conducted an experiment in Pahrump, Nevada, in June 2017, where artificial seismic signals were created using a seismic hammer, and the possibility of detecting them from their acoustic signature was examined. In this work, we analyze the pressure signals recorded by highly sensitive barometers deployed on the ground and on tethers suspended from balloons. Our signal processing results show that wind noise experienced by a barometer on a free-flying balloon is lower compared to one on a moored balloon. This has never been experimentally demonstrated in the lower troposphere. While seismoacoustic signals were not recorded on the hot air balloon platform owing to operational challenges, we demonstrate the detection of seismoacoustic signals on our moored balloon platform. Our results have important implications for performing seismology in harsh surface environments such as Venus through atmospheric remote sensing.

  12. Association between duration of coronary occlusion and high-intensity signal on T1-weighted magnetic resonance imaging among patients with angiographic total occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Sakaguchi, Mikumo; Shimada, Kenei [Osaka City University Graduate School of Medicine, Department of Cardiovascular Medicine, Abeno-ku, Osaka (Japan)

    2017-09-15

    To evaluate the association between duration of the coronary occlusion and high-intensity signal (HIS) on noncontrast T1-weighted imaging using a 1.5-T magnetic resonance imager among patients with angiographic coronary total occlusion. The signal intensity of the coronary target area divided by the signal intensity of the left ventricular muscle near the target area at each site (TMR) was measured. Areas with a TMR >1.0 were defined as HIS. Thirty five lesions from 33 patients were divided into the following three groups: subacute occlusion (up to 3 months; n = 7), short-duration chronic total occlusion (SD-CTO: 3-6 months; n = 9) and long-duration CTO (LD-CTO: ≥6 months; n = 19). All subacute occlusion lesions showed a HIS within the occlusion site. Among patients with CTO, the frequency of a HIS within the occlusion site was significantly higher in SD-CTO than in LD-CTO lesions (p = 0.013). In multivariate analyses, only an occlusion duration of less than 6 months was an independent factor associated with the presence of HIS (odds ratio 7.6, 95% CI 1.1-54.5; p = 0.044). The presence of a HIS in the occlusion site was associated more with SD-CTO than with LD-CTO among patients with CTO. (orig.)

  13. Association between duration of coronary occlusion and high-intensity signal on T1-weighted magnetic resonance imaging among patients with angiographic total occlusion

    International Nuclear Information System (INIS)

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Sakaguchi, Mikumo; Shimada, Kenei

    2017-01-01

    To evaluate the association between duration of the coronary occlusion and high-intensity signal (HIS) on noncontrast T1-weighted imaging using a 1.5-T magnetic resonance imager among patients with angiographic coronary total occlusion. The signal intensity of the coronary target area divided by the signal intensity of the left ventricular muscle near the target area at each site (TMR) was measured. Areas with a TMR >1.0 were defined as HIS. Thirty five lesions from 33 patients were divided into the following three groups: subacute occlusion (up to 3 months; n = 7), short-duration chronic total occlusion (SD-CTO: 3-6 months; n = 9) and long-duration CTO (LD-CTO: ≥6 months; n = 19). All subacute occlusion lesions showed a HIS within the occlusion site. Among patients with CTO, the frequency of a HIS within the occlusion site was significantly higher in SD-CTO than in LD-CTO lesions (p = 0.013). In multivariate analyses, only an occlusion duration of less than 6 months was an independent factor associated with the presence of HIS (odds ratio 7.6, 95% CI 1.1-54.5; p = 0.044). The presence of a HIS in the occlusion site was associated more with SD-CTO than with LD-CTO among patients with CTO. (orig.)

  14. Occlusion Issues in Early Renaissance Art

    Directory of Open Access Journals (Sweden)

    Barbara Gillam

    2011-12-01

    Full Text Available Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surface overlap is often achieved by implementing the principle that an occluding surface occludes anything behind it, so that occlusion perception is enhanced by a lack of relationship of occluding contour to occluded contours. Some well-known figure-ground principles are also commonly used to stratify adjoined figures. Global factors that assist this stratification include the placement of figures on a ground plane, a high viewpoint, and figure grouping. Artists of this period seem to have differed on whether to occlude faces and heads, often carefully avoiding doing so. Halos were either eliminated selectively or placed oddly to avoid such occlusions. Finally, I argue that the marked intransitivity in occlusion by architecture in the paintings of Duccio can be related to the issue of perceptual versus cognitive influences on the visual impact of paintings.

  15. Test ventilation with smoke, bubbles, and balloons

    International Nuclear Information System (INIS)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs

  16. Trace gas measurements from tethered balloon platforms

    Science.gov (United States)

    Bandy, Alan R.; Bandy, Terese L.; Youngbluth, Otto; Owens, Thomas L.

    1987-01-01

    Instrumentation and chemical sampling and analysis procedures are described for making measurements of atmospheric carbon disulfide in the concentration range 1-1000 pptv from tethered balloon platforms. Results of a study on the CS2 composition of air downward of a saltwater marsh are reported. A method for obtaining the necessary data for solving the budget equations for surface fluxes, chemical formation rates and chemical destruction rates using data acquired from tethered balloon platforms is presented.

  17. Modeling self-occlusions in dynamic shape and appearance tracking

    KAUST Repository

    Yang, Yanchao

    2013-12-01

    We present a method to track the precise shape of a dynamic object in video. Joint dynamic shape and appearance models, in which a template of the object is propagated to match the object shape and radiance in the next frame, are advantageous over methods employing global image statistics in cases of complex object radiance and cluttered background. In cases of complex 3D object motion and relative viewpoint change, self-occlusions and disocclusions of the object are prominent, and current methods employing joint shape and appearance models are unable to accurately adapt to new shape and appearance information, leading to inaccurate shape detection. In this work, we model self-occlusions and dis-occlusions in a joint shape and appearance tracking framework. Experiments on video exhibiting occlusion/dis-occlusion, complex radiance and background show that occlusion/dis-occlusion modeling leads to superior shape accuracy compared to recent methods employing joint shape/appearance models or employing global statistics. © 2013 IEEE.

  18. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  19. Preoperative optimization of multi-organ failure following acute myocardial infarction and ischemic mitral regurgitation by placement of a transthoracic intra-aortic balloon pump.

    Science.gov (United States)

    Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M

    2010-10-01

    The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by

  20. Balloon catheter dilatation of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures.

  1. Balloon catheter dilatation of esophageal strictures

    International Nuclear Information System (INIS)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon

    1990-01-01

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures

  2. Performance of the EUSO-Balloon electronics

    International Nuclear Information System (INIS)

    Barrillon, P.; Dagoret, S.; Miyamoto, H.; Moretto, C.; Bacholle, S.; Blaksley, C; Gorodetzky, P.; Jung, A.; Prévôt, G.; Prat, P.; Bayer, J.; Blin, S.; Taille, C. De La; Cafagna, F.; Fornaro, C.; Karczmarczyk, J.; Tanco, G. Medina; Osteria, G.; Perfetto, F.; Park, I.

    2016-01-01

    The 24th of August 2014, the EUSO-Balloon instrument went for a night flight for several hours, 40 km above Timmins (Canada) balloon launching site, concretizing the hard work of an important part of the JEM-EUSO collaboration started 3 years before. This instrument consists of a telescope made of two lenses and a complex electronic chain divided in two main sub-systems: the PDM (Photo Detector Module) and the DP (Data Processor). Each of them is made of several innovative elements developed and tested in a short time. This paper presents their performances before and during the flight

  3. JUBA (Joint UAS-Balloon Activities) Final Campaign Report.

    Energy Technology Data Exchange (ETDEWEB)

    Dexheimer, Darielle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Apple, Monty [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Callow, Diane Schafer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Longbottom, Casey Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Novick, David K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wilson, Christopher W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, JUBA was a collaborative exercise between SNL Orgs. 6533 & 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and UAS on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the ARM AMF3 site at Oliktok Point, Alaska. The Restricted Airspace occupies a 2 nautical mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 – 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability.

  4. External caps: An approach to stress reduction in balloons

    Science.gov (United States)

    Hazlewood, K. H.

    Recent findings of the catastrophic balloon failures investigation in the U.S.A. indicate that very large gross inflations, in balloons using present design philosophy, over-stress currently available materials. External caps are proposed as an economic approach to reducting those stresses to an acceptable level.

  5. Influence of denture adhesives on occlusion and disocclusion times.

    Science.gov (United States)

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (PAdhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Predictors of early stent occlusion among plastic biliary stents.

    Science.gov (United States)

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  7. Balloon dacryocystoplasty: Incomplete versus complete obstruction of the nasolacrimal system

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Sang Hoon; Han, Young Min; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul; Song, Ho Young

    1993-01-01

    Balloon dilatation of nasolacrimal drainage apparatus was attempted for the treatment of stenoses or obstructures of the nasolacrimal system in 49 eyes of 41 consecutive patients with complete obstructions and 16 eyes of 14 patients with incomplete obstructions. These two groups were compared with regards to the effectiveness of balloon dacryocystoplasty. All patients suffered from severe epiphora had already undergone multiple probings. A 0.018 inch hair or ball guide wire was introduced through the superior punctum into the inferior meatus of the nasal cavity and pulled out through the nasal aperture using a hemostat under nasal endoscopy. A deflated angiography balloon catheter was then introduced in a retrograde direction and dilated under fluoroscopic control. No major complications occurred in any of the patients. At 7 days after balloon dilatation, 25 of 49 eyes with complete obstruction demonstrated improvement in epiphora (initial success rate: 51.0%) and among them 17 eyes showed complete resolution of symptoms. Reocclusion occurred in 12 of the 25 eyes with initial improvement at the 2 months follow up. For the 16 eyes with incomplete obstruction, and improvement of epiphora was attained in 11 eyes (initial success rate 68.8%): 5 of these eyes showed complete resolution of epiphora, and 3 was failed to maintain initial improvement at the 2 month follow up. Although this study demonstrate that results of balloon dacryocystoplasty are not encouraging because of the high failure and recurrence rate, balloon dacryocystoplasty is a simple and safe nonsurgical technique that can be used to treat for obstructions of the nasolacrimal system. In addition, balloon dacryocystoplasty shows better results in incomplete obstruction than in complete obstruction than complete obstruction of the nasolacrimal system

  8. OCT evaluation of directional atherectomy compared to balloon angioplasty

    International Nuclear Information System (INIS)

    Marmagkiolis, Konstantinos; Lendel, Vasili; Cilingiroglu, Mehmet

    2015-01-01

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  9. OCT evaluation of directional atherectomy compared to balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Marmagkiolis, Konstantinos [Citizens Memorial Hospital Heart and Vascular Institute, Bolivar, MO (United States); Lendel, Vasili [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2015-09-15

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  10. The effect of pressure anisotropy on ballooning modes in tokamak plasmas

    Science.gov (United States)

    Johnston, A.; Hole, M. J.; Qu, Z. S.; Hezaveh, H.

    2018-06-01

    Edge Localised Modes are thought to be caused by a spectrum of magnetohydrodynamic instabilities, including the ballooning mode. While ballooning modes have been studied extensively both theoretically and experimentally, the focus of the vast majority of this research has been on isotropic plasmas. The prevalence of pressure anisotropy in modern tokamaks thus motivates further study of these modes. This paper presents a numerical analysis of ballooning modes in anisotropic equilibria. The investigation was conducted using the newly-developed codes HELENA+ATF and MISHKA-A, which adds anisotropic physics to equilibria and stability analysis. We have examined the impact of anisotropy on the stability of an n = 30 ballooning mode, confirming results conform to previous calculations in the isotropic limit. Growth rates of ballooning modes in equilibria with different levels of anisotropy were then calculated using the stability code MISHKA-A. The key finding was that the level of anisotropy had a significant impact on ballooning mode growth rates. For {T}\\perp > {T}| | , typical of ICRH heating, the growth rate increases, while for {T}\\perp < {T}| | , typical of neutral beam heating, the growth rate decreases.

  11. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment

    International Nuclear Information System (INIS)

    Saini, Amarjit S.; Zhang, Geoffrey G.; Finkelstein, Steven E.; Biagioli, Matthew C.

    2011-01-01

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken with each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 ± 0.002 for contrast/saline solution and 0.808 ± 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 ± 0.010 and 0.781 ± 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.

  12. A balloon-borne prototype for demonstrating the concept of JEM-EUSO

    Science.gov (United States)

    von Ballmoos, P.; Santangelo, A.; Adams, J. H.; Barrillon, P.; Bayer, J.; Bertaina, M.; Cafagna, F.; Casolino, M.; Dagoret, S.; Danto, P.; Distratis, G.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Evrard, J.; Gorodetzky, Ph.; Haungs, A.; Jung, A.; Kawasaki, Y.; Medina-Tanco, G.; Mot, B.; Osteria, G.; Parizot, E.; Park, I. H.; Picozza, P.; Prévôt, G.; Prieto, H.; Ricci, M.; Rodríguez Frías, M. D.; Roudil, G.; Scotti, V.; Szabelski, J.; Takizawa, Y.; Tusno, K.

    2014-05-01

    EUSO-BALLOON has been conceived as a pathfinder for JEM-EUSO, a mission concept for a space-borne wide-field telescope monitoring the Earth's nighttime atmosphere with the objective of recording the ultraviolet light from tracks initiated by ultra-high energy cosmic rays. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-BALLOON will serve as a test-bench for the key technologies of JEM-EUSO. EUSO-BALLOON shall perform an end-to-end test of all subsystems and components, and prove the global detection chain while improving our knowledge of the atmospheric and terrestrial ultraviolet background. The balloon-instrument also has the potential to detect for the first time UV-light generated by atmospheric air-shower from above, marking a milestone in the development of UHECR science, and paving the way for any future large scale, space-based ultra-high energy cosmic ray observatory.

  13. [Case report of occlusal treatment with full mouth reconstruction].

    Science.gov (United States)

    Oizumi, Makoto

    2008-07-01

    A 70-year-old woman presented with a complaint of masticatory pain and disturbance. She had collapse of occlusal support and vertical dimension decrease. This case used provisional restoration for increasing vertical dimension and reconstruction of anterior guidance. After confirming occlusal stability, she was treated with fixed prosthesis and removable partial dentures. This patient was followed for 6 and a half years with no prosthetic complications, because the reconstruction of bilateral occlusal support and anterior guidance were performed. It is important to reconstruct the occlusal support and anterior guidance in cases of prosthetic treatment of occlusal collapse.

  14. [Occlusal schemes of complete dentures--a review of the literature].

    Science.gov (United States)

    Tarazi, E; Ticotsky-Zadok, N

    2007-01-01

    Occlusal scheme is defined as the form and the arrangement of the occlusal contacts in natural and artificial dentition. The choice of an occlusal scheme will determine the pattern of occlusal contacts between opposing teeth during centric relation and functional movement of the mandible. With dentures, the quantity and the intensity of these contacts determine the amount and the direction of the forces that are transmitted through the bases of the denture to the residual ridges. That is why the occlusal scheme is an important factor in the design of complete dentures. Three occlusal schemes are viewed in this review: bilateral balanced occlusion, monplane occlusion, and linear occlusion scheme. Each scheme represents a different concept of occlusion. Comparisons between these schemes are also reviewed and analyzed. The reasoning underlying the bilateral balanced occlusion scheme is that stability of the dentures is attained when bilateral contacts exist throughout all dynamic and static states of the denture during function. Anatomic teeth are used: the upper anterior teeth are set to satisfy aesthetics, and the posterior teeth are arranged in a compensatory curve and a medial curve. This scheme is adequate for well developed residual ridges, with skeletal class I relation. With highly resorbed residual ridges, the vectors of force that are transmitted through anatomic cusps will dislodge the lower denture and thus impair the comfort and efficiency of mastication experienced by the patient. In order to accommodate to the special needs posed by highly resorbed residual ridges and skeletal relations that are not class I, the monoplane scheme of occlusion was designed. This scheme consists of non anatomic (cuspless) teeth, which are set so that the anterior teeth provide the aesthetics, the premolars and the first molars are used for chewing, and the second molars do not occlude (although sometimes they are specifically used to establish bilateral contacts in lateral

  15. MHD Ballooning Instability in the Plasma Sheet

    International Nuclear Information System (INIS)

    Cheng, C.Z.; Zaharia, S.

    2003-01-01

    Based on the ideal-MHD model the stability of ballooning modes is investigated by employing realistic 3D magnetospheric equilibria, in particular for the substorm growth phase. Previous MHD ballooning stability calculations making use of approximations on the plasma compressibility can give rise to erroneous conclusions. Our results show that without making approximations on the plasma compressibility the MHD ballooning modes are unstable for the entire plasma sheet where beta (sub)eq is greater than or equal to 1, and the most unstable modes are located in the strong cross-tail current sheet region in the near-Earth plasma sheet, which maps to the initial brightening location of the breakup arc in the ionosphere. However, the MHD beq threshold is too low in comparison with observations by AMPTE/CCE at X = -(8 - 9)R(sub)E, which show that a low-frequency instability is excited only when beq increases over 50. The difficulty is mitigated by considering the kinetic effects of ion gyrorad ii and trapped electron dynamics, which can greatly increase the stabilizing effects of field line tension and thus enhance the beta(sub)eq threshold [Cheng and Lui, 1998]. The consequence is to reduce the equatorial region of the unstable ballooning modes to the strong cross-tail current sheet region where the free energy associated with the plasma pressure gradient and magnetic field curvature is maximum

  16. Double balloon esophageal catheter for diagnosis of tracheo-esophageal fistula

    International Nuclear Information System (INIS)

    Kiyan, Guersu; Dagli, Tolga E.; Tugtepe, Halil; Kodalli, Nihat

    2003-01-01

    Congenital H-type and recurrent tracheo-esophageal fistulas (TEF) are always difficult to diagnose. For a more accurate diagnosis we designed a new double balloon catheter, which is a modification of esophageal dilatation balloon. The catheter has two balloons to occlude the esophagus proximal and distal to the fistula. The fistula can be identified by passing of the contrast material to the tracheal tree, which was injected into the esophageal segment between the inflated balloons. To prove the efficiency of this catheter, a TEF was created surgically in a New Zealand rabbit. On the postoperative fourteenth day the catheter was tried and the fistula could be visualized easily by injecting the contrast material. We think this technique may be of use in the diagnosis of TEF in children. (orig.)

  17. Occlusal stability in shortened dental arches.

    NARCIS (Netherlands)

    Witter, D.J.; Creugers, N.H.J.; Kreulen, C.M.; Haan, A. de

    2001-01-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a

  18. The UK sounding rocket and balloon programme

    International Nuclear Information System (INIS)

    Delury, J.T.

    1980-01-01

    The UK civil science balloon and rocket programmes for 1979/80/81 are summarised and the areas of scientific interest for the period 1981/85 mentioned. In the main the facilities available are 10 in number balloons up to 40 m cu ft launched from USA or Australia and up to 10 in number 7 1/2'' diameter Petrel rockets. This paper outlines the 1979 and 1980 programmes and explains the longer term plans covering the next 5 years. (Auth.)

  19. Second-generation endometrial ablation technologies: the hot liquid balloons.

    Science.gov (United States)

    Vilos, George A; Edris, Fawaz

    2007-12-01

    Hysteroscopic endometrial ablation (HEA) was introduced in the 1980s to treat menorrhagia. Its use required additional training, surgical expertise and specialized equipment to minimize emergent complications such as uterine perforations, thermal injuries and excessive fluid absorption. To overcome these difficulties and concerns, thermal balloon endometrial ablation (TBEA) was introduced in the 1990s. Four hot liquid balloons have been introduced into clinical practice. All systems consist of a catheter (4-10mm diameter), a silicone balloon and a control unit. Liquids used to inflate the balloons include internally heated dextrose in water (ThermaChoice, 87 degrees C), and externally heated glycine (Cavaterm, 78 degrees C), saline (Menotreat, 85 degrees ) and glycerine (Thermablate, 173 degrees C). All balloons require pressurization from 160 to 240 mmHg for treatment cycles of 2 to 10 minutes. Prior to TBEA, preoperative endometrial thinning, including suction curettage, is optional. Several RCTs and cohort studies indicate that the advantages of TBEA include portability, ease of use and short learning curve. In addition, small diameter catheters requiring minimal cervical dilatation (5-7 mm) and short duration of treatment cycles (2-8 min) allow treatment under minimal analgesia/anesthesia requirements in a clinic setting. Following TBEA serious adverse events, including thermal injuries to viscera have been experienced. To minimize such injuries some surgeons advocate the use of routine post-dilatation hysteroscopy and/or ultrasonography to confirm correct intrauterine placement of the balloon prior to initiating the treatment cycle. After 10 years of clinical practice, TBEA is thought to be the preferred first-line surgical treatment of menorrhagia in appropriately selected candidates. Economic modeling also suggested that TBEA may be more cost-effective than HEA.

  20. Scientific ballooning. Proceedings. PSB Meeting of the COSPAR Panel on Technical Problems Related to Scientific Ballooning which was held during the Thirtieth COSPAR Scientific Assembly, Hamburg (Germany), 11 - 21 Jul 1994.

    Science.gov (United States)

    Riedler, W.; Torkar, K.

    1996-05-01

    This issue is grouped into sections on materials, design, performance and analysis of balloons, reviews of major national and international balloon programmes, novel instrumentation and systems for scientific ballooning, and selected recent scientific observations.

  1. High Altitude Infrasound Measurements using Balloon-Borne Arrays

    Science.gov (United States)

    Bowman, D. C.; Johnson, C. S.; Gupta, R. A.; Anderson, J.; Lees, J. M.; Drob, D. P.; Phillips, D.

    2015-12-01

    For the last fifty years, almost all infrasound sensors have been located on the Earth's surface. A few experiments consisting of microphones on poles and tethered aerostats comprise the remainder. Such surface and near-surface arrays likely do not capture the full diversity of acoustic signals in the atmosphere. Here, we describe results from a balloon mounted infrasound array that reached altitudes of up to 38 km (the middle stratosphere). The balloon drifted at the ambient wind speed, resulting in a near total reduction in wind noise. Signals consistent with tropospheric turbulence were detected. A spectral peak in the ocean microbarom range (0.12 - 0.35 Hz) was present on balloon-mounted sensors but not on static infrasound stations near the flight path. A strong 18 Hz signal, possibly related to building ventilation systems, was observed in the stratosphere. A wide variety of other narrow band acoustic signals of uncertain provenance were present throughout the flight, but were absent in simultaneous recordings from nearby ground stations. Similar phenomena were present in spectrograms from the last balloon infrasound campaign in the 1960s. Our results suggest that the infrasonic wave field in the stratosphere is very different from that which is readily detectable on surface stations. This has implications for modeling acoustic energy transfer between the lower and upper atmosphere as well as the detection of novel acoustic signals that never reach the ground. Our work provides valuable constraints on a proposed mission to detect earthquakes on Venus using balloon-borne infrasound sensors.

  2. Influence of the quality of the finished occlusion on postretention occlusal relapse.

    Science.gov (United States)

    de Freitas, Karina Maria Salvatore; Janson, Guilherme; de Freitas, Marcos Roberto; Pinzan, Arnaldo; Henriques, José Fernando Castanha; Pinzan-Vercelino, Célia Regina Maio

    2007-10-01

    In this study, we aimed to evaluate the influence of the quality of the finished occlusion on postretention occlusal stability. The sample comprised 87 patients with Class I malocclusion, treated with extraction of the 4 first premolars and edgewise mechanics; they were divided into 2 groups, according to the quality of their finished occlusions. Group 1 included 44 subjects (23 boys, 21 girls) with posttreatment peer assessment rating (PAR) scores from 0 to 5. The mean pretreatment age was 13.74 years (SD 2.14). The mean treatment time was 1.92 years (SD 0.57), the mean retention time was 1.75 years (SD 0.96), and the mean time of posttreatment evaluation was 5.17 years (SD 1.82). Group 2 included 43 subjects (22 boys, 21 girls) with posttreatment PAR scores greater than 5. The mean initial age was 13.34 years (SD 1.35). The mean treatment time was 2.20 years (SD 0.66), the mean retention time was 1.77 years (SD 0.78), and the mean posttreatment evaluation was 5.47 years (SD 1.60). The PAR and the Little irregularity indexes were measured on the dental casts at pretreatment, posttreatment, and postretention. Intergroup comparisons were made with independent t tests, and the Pearson correlation coefficient was applied to the PAR score for the whole sample at the times evaluated. Well-finished patients had lower posttreatment and postretention PAR scores and greater changes during the treatment and posttreatment periods than did the poorly finished patients. For the Little irregularity index, the only difference between the groups was at the posttreatment stage; group 1 had a smaller irregularity score than group 2. The correlation coefficients showed that the greater the treatment changes, the smaller the posttreatment PAR score and the greater the relapse. But the higher the posttreatment PAR score, the higher the postretention PAR score. It was concluded that the greater the quality of the orthodontic finished occlusion, the greater are the treatment changes and

  3. Analysis of current diffusive ballooning mode in tokamaks

    International Nuclear Information System (INIS)

    Uchida, M.; Fukuyama, A.; Itoh, S.-I.; Yagi, M.

    1999-12-01

    The effect of finite gyroradius on the current diffusive ballooning mode is examined. Starting from the reduced MHD equations including turbulent transports, coupling with drift motion and finite gyroradius effect of ions, we derive a ballooning mode equation with complex transport coefficients. The eigenfrequency, saturation level and thermal diffusivity are evaluated numerically from the marginal stability condition. Preliminary results of their parameter dependence is presented. (author)

  4. [Gnathosonics study of the occlusal stability of orthodontic patients].

    Science.gov (United States)

    Jiang, Ruo-Ping; Tyson, Kenneth W

    2008-02-18

    To analysis the stability of the occlusion before and after the orthodontic treatment by gnathosonics; To evaluate the reliability of the stethoscope method by comparing the subjective(stethoscopy) and objective(digital occlusal sound recording) methods of checking the occlusal sound. Sixty-four new patients with malocclusion were selected as the before treatment group, these patients were not subject to any previous orthodontic treatment, facial surgery or injury; the treatment complete group included 15 patients who were just debonded the fixed appliance. Both stethoscope and digital occlusal sound recording were used to evaluate the occlusal sound. The occlusal stability before and after orthodontic treatment was compared depending on the results from the objective examination. The stability of the occlusion between different types of malocclusion before treatment was compared also. The veracity and reliability of the stethoscope method were analysis using the objective method as the golden standard. (1) 43.75%(28/64) of the 64 new patients showed unstable occlusal sound. ANOVA test showed that there were no statistically significant differences between the unstable rates in different type of malocclusion. (2) 40% (6/15) of the 15 treatment complete patients had unstable occlusions. (3) There were no statistically significant differences between the unstable rate pre- and post-treatment. (4) The veracity of the stethoscopes was 81.01% (64/79). (5) Kappa test showed that the stethoscopes and the digital recording method were consistent; the Kappa value was 0.488, Pocclusion rate between the two groups, and between the different types of malocclusion before treatment. (2) Using stethoscopes method to check the occlusal sound is reliable. The veracity could be improved significantly with increased experiences.

  5. Morphological characteristics of chronic total occlusion. Predictors of different strategies for long-segment femoral arterial occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Li-Ming; Zhu, Yue-Qi; Zhang, Pei-Lei; Lu, Hai-Tao; Zhao, Jun-Gong [Shanghai Jiaotong University Affiliated Sixth People' s Hospital, Department of Diagnostic and Interventional Radiology, Shanghai (China); Liu, Fang [Shanghai Jiaotong University Affiliated Sixth People' s Hospital, Department of Endocrinology, Shanghai (China)

    2018-03-15

    To investigate morphological characteristics used to predict recanalisation strategies in long-segment (>10 cm) femoral chronic total occlusion (LSF-CTO) angioplasty. We retrospectively evaluated a range of morphological CTA and DSA features in patients who underwent recanalisation of LSF-CTO. The stage of CTO was classified into early (3-12 months) and late (>12 months) according to estimated duration. Characteristics including stump morphology, lesion length and calcification, proximal side branches, collaterals circulation, runoff vessels and concomitant arterial occlusion were used as predictors, and multivariate logistic regression analysis was performed to identify variables associated with late-stage CTO and retrograde technique. A total of 119 patients with 137 CTOs in 137 limbs were enrolled. Overall, successful recanalisation was achieved in 122 CTOs (89.1%). Flush occlusion [odds ratio (OR) 2.958; 95% confidence interval (CI) 1.172-7.465; p = 0.022], large collateral (OR 2.778; 95% CI 1.201-6.427; p = 0.017) and TransAtlantic Inter-Society Consensus II class D (TASC D) lesion (OR 1.743; 95% CI 1.019-2.981; p = 0.042) were predictors for late-stage CTO. Flush occlusion (OR 75.278; 95% CI 10.664-531.384; p < 0.001) and large collateral (OR 23.213; 95% CI 3.236-166.523; p = 0.002) were associated with high likelihood for retrograde approach. Flush occlusion and large collateral were associated with a CTO at late-stage which may require retrograde recanalisation. (orig.)

  6. Robotic weather balloon launchers spread in Alaska

    Science.gov (United States)

    Rosen, Julia

    2018-04-01

    Last week, things began stirring inside the truck-size box that sat among melting piles of snow at the airport in Fairbanks, Alaska. Before long, the roof of the box yawned open and a weather balloon took off into the sunny afternoon, instruments dangling. The entire launch was triggered with the touch of a button, 5 kilometers away at an office of the National Weather Service (NWS). The flight was smooth, just one of hundreds of twice-daily balloon launches around the world that radio back crucial data for weather forecasts. But most of those balloons are launched by people; the robotic launchers, which are rolling out across Alaska, are proving to be controversial. NWS says the autolaunchers will save money and free up staff to work on more pressing matters. But representatives of the employee union question their reliability, and say they will hasten the end of Alaska's remote weather offices, where forecasting duties and hours have already been slashed.

  7. Concepts of occlusion in prosthodontics: A literature review, part I

    Directory of Open Access Journals (Sweden)

    V Rangarajan

    2015-01-01

    Full Text Available Occlusion and its relationship to the function of the stomatognathic system have been widely studied in dentistry since many decades. This series of articles describe about occlusion in the complete denture, fixed partial denture, and implants. Part I and II of this articles series describe concepts and philosophies of occlusion in complete denture. So far, available research has not concluded a superior tooth form or occlusal scheme to satisfy the requirements of completely edentulous patients with respect to comfort, mastication, phonetics, and esthetics. Since then, several balanced and nonbalanced articulation concepts were proposed in the literature. A balanced articulation appears to be most appropriate because of tooth contacts observed during nonfunctional activities of patients. This article discusses about evolution of different concepts of occlusion and occlusal schemes in complete denture occlusion.

  8. Depicting Occlusion in Early Renaissance Art

    Directory of Open Access Journals (Sweden)

    Barbara Gillam

    2011-05-01

    Full Text Available The artist attempting to give the impression of three-dimensional relationships must convey somehow that one surface is in front of another. There is a large and venerable literature in Psychology on this subject, showing how figure-ground, border ownership and amodal completion and continuation are determined but there is almost no discussion of how artist's have recruited these and other principles to create convincing impressions of occlusion. Even Gombrich (Art & Illusion 1960 only considers the situation in which a figure has to be imagined from very partial cues, not how juxtaposed elements in art are parsed perceptually into occluding and occluded surfaces. In this paper I shall discuss approaches to occlusion present in early Renaissance art and the degree to which the principles now well-known to Psychologists were discovered and used, as artists increasingly depicted naturalistic scenes. Among the preoccupations of these artists, as indicated by their work, were whether and how much to occlude faces (and the related issue of the management of haloes, occlusion of and by architectural features, and the importance or otherwise of transitivity in occlusion relationships within the scene. They also clearly used the ground plane, high viewpoints and arrangements of contour terminations, as well as more conventional figural cues, to disambiguate perceived occlusion or to avoid the confusion of multiple surfaces.

  9. Retrieving Balloon Data in Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Ultra Long Duration Balloon (ULDB) program will soon make flights lasting up to 100 days. Some flights may generate high data rates and retrieving this data...

  10. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  11. Endovascular obliteration of bleeding duodenal varices in patients with liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Zamora, Carlos Armando; Sugimoto, Koji; Tsurusaki, Masakatsu; Izaki, Kenta; Fukuda, Tetsuya; Matsumoto, Shinichi; Kawasaki, Ryota; Taniguchi, Takanori; Sugimura, Kazuro [Kobe University School of Medicine, Department of Radiology, Kobe-shi, Hyogo-ken (Japan); Kuwata, Yoichiro [Nishi-Kobe Medical Center, Department of Radiology, Kobe-shi, Hyogo-ken (Japan); Hirota, Shozo [Hyogo Medical College, Department of Radiology, Nishinomiya-shi, Hyogo-ken (Japan)

    2006-01-01

    The purpose of this paper is to describe our experience with endovascular obliteration of duodenal varices in patients with liver cirrhosis and portal hypertension. Balloon-occluded transvenous retrograde and percutaneous transhepatic anterograde embolizations were performed for duodenal varices in five patients with liver cirrhosis, portal hypertension, and decreased liver function. All patients had undergone previous endoscopic treatments that failed to stop bleeding and were poor surgical candidates. Temporary balloon occlusion catheters were used to achieve accumulation of an ethanolamine oleate-iopamidol mixture inside the varices. Elimination of the varices was successful in all patients. Retrograde transvenous obliteration via efferent veins to the inferior vena cava was enough to achieve adequate sclerosant accumulation in three patients. A combined anterograde-retrograde embolization was used in one patient with balloon occlusion of afferent and efferent veins. Transhepatic embolization through the afferent vein was performed in one patient under balloon occlusion of both efferent and afferent veins. There was complete variceal thrombosis and no bleeding was observed at follow-up. No major complications were recorded. Endovascular obliteration of duodenal varices is a feasible and safe alternative procedure for managing patients with portal hypertension and hemorrhage from this source. (orig.)

  12. Relationship of Occlusal Schemes with the Occurrence of Temporomandibular Disorders

    Directory of Open Access Journals (Sweden)

    Dina H. Sugiaman

    2013-07-01

    Full Text Available Masticatory system is a complex functional unit of the body responsible for mastication, speech, and deglutition process. Temporomandibular disorders (TMD is used to describe all functional disturbances of the masticatory system. The etiology of TMD is multifactorial, such as occlusal disharmony and emotional stress. The relationship between occlusion and TMD has been highly debated in dentistry, one of the occlusal factors is the occlusal scheme. Occlusal schemes are defined as bilateral canine guidance, unilateral canine guidance, group function and balanced occlusion. However, studies about the relationship of occlusal schemes and the occurrence of the TMD are still limited and remained controversial. Objective: To investigate the relationship of occlusal schemes witht he occurrence of TMD. Methods: A cross-sectional study was conducted at the Faculty of Dentistry, Uniiversitas Indonesia. A total of 127 students were included in this study. Subjects were examined based on Clinical Helkimo Index and divided into TMD and non-TMD groups. Subjects were categorized as non-TMD groups if the value of the clinical Helkimo index was 0 and as TMD group when the value ranged between 1-25. Results: Balanced occlusion schemes has a greater risk of TMD occurrence with odds ratio value 5.6 and 95% confidence interval 1.188 to 26.331 (p=0.021. Conclusion: Balanced occlusion has a significant relationship with the occurrence of TMD.

  13. SBARMO-79 a multi-balloon campaign in the auroral zone

    International Nuclear Information System (INIS)

    Tanskanen, P.; Kangas, J.; Bjordal, J.; Bronstad, K.; Block, L.P.; Holtet, T.

    1982-01-01

    A joint European International Magnetospheric Study (IMS) balloon campaign was conducted within the framework of the Scientific Ballooning and Radiation Monitoring Organization (SBARMO). The campaign was carried out during the time from May 30 to July 10, 1979. A total of 29 successful balloon launches were made from four launch sites located in Norway and in Finland. The campaign has the objective to provide information for a better understanding of temporal and spatial variations of magnetospheric processes, giving particular attention to the coupling between the magnetosphere and the ionosphere

  14. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  15. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    International Nuclear Information System (INIS)

    Lopera, Jorge E.; Alvarez, Alex; Trimmer, Clayton; Josephs, Shellie; Anderson, Matthew; Dolmatch, Bart

    2009-01-01

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm 3 , respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

  16. Contemporary treatment of patients with chronic total occlusion: critical appraisal of different state-of-the-art techniques and devices.

    Science.gov (United States)

    García-García, Héctor M; Kukreja, Neville; Daemen, Joost; Tanimoto, Shuzou; van Mieghem, Carlos; Gonzalo, Nieves; van Weenen, Sander; van der Ent, Martin; Sianos, Georgios; de Feyter, Pim; Serruys, Patrick W

    2007-08-01

    To describe the contemporary approach of chronic total occlusion (CTO) treatment of patients at the Thoraxcenter, Rotterdam, The Netherlands. Additionally, to make a critical appraisal of the performance of state-of-the-art CTO dedicated guidewires and devices in a prospective registry of patients. During 20 months, a total of 160 consecutive patients (165 CTOs) were enrolled. The mean age was 61.5+/-11.1 years and 83.6% were male. In 91.5% of the patients this was the first attempt to open the CTO and 93.8% were de novo. The overall success rate was 60.6%. A median of 1 guiding catheter was used per case (Range: 1 to 9) and a median of 4 guidewires (Range: 1 to 11; 13 different types). 74.5% patients required more than one guidewire/device for the treatment of the CTO. The guidewires that most frequently crossed the CTO were the following: PT Graphix intermediate 33.0%, Miracle 3 g 27.4% and Crosswire NT 25.5%. The only device tested as a first option for the treatment of the CTOs was the CROSSER. Overall, the CROSSER system was used in 23 (13.9%) patients with a success rate of 60.9%. The Point 9(R) X-80 Laser catheter was used in 10 (6.1%) patients with a success rate of 60%. Another 3 patients were treated with the Point 7(R) laser catheter. Both were used either to facilitate the crossing of the balloon, or to treat primarily in-stent restenosis occlusions. The SafeCross(R) System was used in 15 (9.1%) patients and the success rate in these patients was 46.7%. The most common strategy used in this registry was the use of an over-the-wire balloon in 81.5% of the cases. The parallel wire technique was used in 27.3% of the cases and in 12.7% was converted into a "see-saw" technique. When a large false lumen was created, re-entry into the true lumen was attempted in 21.2% of the cases, by means of IVUS guided approach and/or the use of stiffer guidewires, such as a Confianza guidewire. Retrograde recanalisation was attempted in 10 cases (6.1%), in three cases a

  17. Part-time occlusion therapy for amblyopia in older children.

    Science.gov (United States)

    Singh, Inderpreet; Sachdev, Nishant; Brar, Gagandeep S; Kaushik, Sushmita

    2008-01-01

    To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57), strabismic (25) and mixed (18) unilateral amblyopia were randomized (simple randomization) into four groups (25 each) to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. All four groups showed significant visual improvement after 18 weeks of occlusion therapy ( P amblyopia therapy with 11 eyes (44%), 17 eyes (68%), 22 eyes (88%) and 23 eyes (92%) being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80), there was no significant difference in visual outcome among the four groups ( P =0.083). However, in severe amblyopia (vision 20/100 or worse), six hours ( P =0.048) and full-time occlusion ( P =0.027) treatment were significantly more effective than two hours occlusion. All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy.

  18. Hydrocolloid occlusion for the treatment of neurovascular corns

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Beck, Jan Walther; Reumert, L N

    1991-01-01

    The goal of this study was to determine the effect of hydrocolloid occlusion on neurovascular corns. The design was an observer-blinded, randomized, controlled study. Thirty consecutive patients participated in the trial. The patients received curettage alone or curettage with hydrocolloid...... occlusion. Six treatments were given over 12 weeks. A follow-up examination was performed 3 months after termination of the trial. Outcome measures were the size of the corns, a discomfort score, and an overall judgment of the trial. The results demonstrated no benefit of occlusion for symptoms or signs...... of neurovascular corns. The patients treated with occlusion were, however, generally more satisfied than the conventional group....

  19. Radiation Retinopathy Associated with Central Retinal Vein Occlusion

    Institute of Scientific and Technical Information of China (English)

    Yan; Liu; FengWen

    2007-01-01

    Purpose: To report a case of radiation retinopathy associated with central retinal vein occlusion.Methods: The clinical features and fundus fluorescein angiography of this case were analyzed.Results: The patient had been treated with radiotherapy for her nasopharyngeal carcinoma, and presented with sudden visual loss in the left eye. The funduscopic examination and fluorescein angiography showed the features of radiation retinopathy in both eyes, and central retinal vein occlusion in the left eye.Conclusions: Radiation retinopathy can be associated with central retinal vein occlusion in the same eye, and it seems that the endothelial cell loss caused by radiation retinopathy may lead to retinal vein occlusion.

  20. A local network integrated into a balloon-borne apparatus

    Science.gov (United States)

    Imori, Masatosi; Ueda, Ikuo; Shimamura, Kotaro; Maeno, Tadashi; Murata, Takahiro; Sasaki, Makoto; Matsunaga, Hiroyuki; Matsumoto, Hiroshi; Shikaze, Yoshiaki; Anraku, Kazuaki; Matsui, Nagataka; Yamagami, Takamasa

    A local network is incorporated into an apparatus for a balloon-borne experiment. A balloon-borne system implemented in the apparatus is composed of subsystems interconnected through a local network, which introduces modular architecture into the system. The network decomposes the balloon-borne system into subsystems, which are similarly structured from the point of view that the systems is kept under the control of a ground station. The subsystem is functionally self-contained and electrically independent. A computer is integrated into a subsystem, keeping the subsystem under the control. An independent group of batteries, being dedicated to a subsystem, supplies the whole electricity of the subsystem. The subsystem could be turned on and off independently of the other subsystems. So communication among the subsystems needs to be based on such a protocol that could guarantee the independence of the individual subsystems. An Omninet protocol is employed to network the subsystems. A ground station sends commands to the balloon-borne system. The command is received and executed at the system, then results of the execution are returned to the ground station. Various commands are available so that the system borne on a balloon could be controlled and monitored remotely from the ground station. A subsystem responds to a specific group of commands. A command is received by a transceiver subsystem and then transferred through the network to the subsystem to which the command is addressed. Then the subsystem executes the command and returns results to the transceiver subsystem, where the results are telemetered to the ground station. The network enhances independence of the individual subsystems, which enables programs of the individual subsystems to be coded independently. Independence facilitates development and debugging of programs, improving the quality of the system borne on a balloon.

  1. Volumetric ambient occlusion for real-time rendering and games.

    Science.gov (United States)

    Szirmay-Kalos, L; Umenhoffer, T; Toth, B; Szecsi, L; Sbert, M

    2010-01-01

    This new algorithm, based on GPUs, can compute ambient occlusion to inexpensively approximate global-illumination effects in real-time systems and games. The first step in deriving this algorithm is to examine how ambient occlusion relates to the physically founded rendering equation. The correspondence stems from a fuzzy membership function that defines what constitutes nearby occlusions. The next step is to develop a method to calculate ambient occlusion in real time without precomputation. The algorithm is based on a novel interpretation of ambient occlusion that measures the relative volume of the visible part of the surface's tangent sphere. The new formula's integrand has low variation and thus can be estimated accurately with a few samples.

  2. Paraspinal arteriovenous malformation Onyx embolization via an Ascent balloon.

    Science.gov (United States)

    Martínez-Galdámez, Mario; Rodriguez-Arias, Carlos A; Utiel, Elena; Arreba, Emilio; Gonzalo, Miguel; Arenillas, Juan F

    2014-04-01

    Purely extradural lumbar spinal arteriovenous malformations (AVMs) are rare lesions that have diverse presentations and imaging features. The treatment of a symptomatic high flow paraspinal AVM with multiple feeders remains a challenge. We report the first use of an Ascent balloon (dual lumen balloon catheter) to deliver Onyx with excellent penetration to a paraspinal AVM.

  3. Experimental investigation of undesired stable equilibria in pumpkin shape super-pressure balloon designs

    Science.gov (United States)

    Schur, W. W.

    2004-01-01

    Excess in skin material of a pneumatic envelope beyond what is required for minimum enclosure of a gas bubble is a necessary but by no means sufficient condition for the existence of multiple equilibrium configurations for that pneumatic envelope. The very design of structurally efficient super-pressure balloons of the pumpkin shape type requires such excess. Undesired stable equilibria in pumpkin shape balloons have been observed on experimental pumpkin shape balloons. These configurations contain regions with stress levels far higher than those predicted for the cyclically symmetric design configuration under maximum pressurization. Successful designs of pumpkin shape super-pressure balloons do not allow such undesired stable equilibria under full pressurization. This work documents efforts made so far and describes efforts still underway by the National Aeronautics and Space Administration's Balloon Program Office to arrive on guidance on the design of pumpkin shape super-pressure balloons that guarantee full and proper deployment.

  4. Clinical application of Inoue-balloon in percutaneous transluminal angioplasty for Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Mei Jian; Qu Jian; Zhu Yaoqing; Wang Lei; Liu Cheng

    2007-01-01

    Objective: To investigate the feasibility and effect of recanalization of inferior vena cava with percutaneous transluminal angioplasty(PTA)by Inoue-balloon. Methods: Eighty-nine patients with Budd-chiari syndrome (BCS )were treated with PTA by Inoue-balloon. Results: After PTA, the median (interquartile range)diameter of hepatic segment inferior vena cava increased from 0.00 (0.20-0.00) cm to 1.90 (2.00 1.47)cm; (P < 0.001), and the mean pressure of inferior vena cava reduced from (20.63 ± 7.22) mmHg to (12.13 ± 5.60) mmHg; (P < 0.001); with only less serious complications as rupture in two cases and without need of prior minor diameter balloon dilation in Inoue-balloon PTA. Conclusion: The advantages of Inoue- balloon PTA for BCS are more reliable and facile than those of polyethylene balloon, and may take the place in the foreseen future. (authors)

  5. Impact of contrast agent viscosity on coronary balloon deflation times: bench testing results.

    Science.gov (United States)

    Mogabgab, Owen; Patel, Vishal G; Michael, Tesfaldet T; Kotsia, Anna; Christopoulos, George; Banerjee, Subhash; Brilakis, Emmanouil S

    2014-04-01

    To assess the impact of viscosity on angioplasty balloon deflation times. Lower contrast viscosity could result in more rapid coronary balloon deflation times. We performed a bench comparison of coronary balloon deflation times using 2 contrast agents with different viscosity (ioxaglate and iodixanol), 3 contrast dilutions, and 2 inflation syringe filling volumes. Ten identical pairs of coronary angioplasty balloons were used to conduct each comparison after balloon inflation to 12 atmospheres. Simultaneous deflations were performed under cineangiography. The time to full contrast extraction and the area of contrast remaining after 5 seconds of deflation (quantified by opaque pixel count) were compared between groups. The mean time to full contrast extraction during balloon deflation was 8.3 ± 2.5 seconds for ioxaglate (lower viscosity) versus 10.1 ± 2.9 seconds for iodixanol (higher viscosity) (17.4% decrease, P = 0.005), with a 35.6% (P = 0.004) reduction in contrast area at 5 seconds. Compared to 1:1 ioxaglate-saline mixture, 1:2 and 1:3 ioxaglate/saline mixes resulted in 26.7% (P deflation time, respectively, but at the expense of decreased balloon opacity. Filling the inflation syringe with 5 versus 15 ml of contrast/saline solution was associated with 7.5% decrease in balloon deflation time (P = 0.005), but no difference in contrast area at 5 seconds (P = 0.749). Use of a lower viscosity contrast agent and higher contrast dilution significantly reduced coronary balloon deflation times, whereas use of lower syringe filling volume had a modest effect. Rapid coronary balloon deflation could improve the safety of interventional procedures. © 2014 Wiley Periodicals, Inc.

  6. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    Directory of Open Access Journals (Sweden)

    Hee Young Cho

    Full Text Available The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation.We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL.Sixty-four patients (46.7% required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1% had placenta previa totalis. The overall success rate was 75% (48/64 for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05. The drainage amount over 1 hour was 500 mL (20-1200 mL in the balloon failure group and 60 mL (5-500 mL in the balloon success group (p<0.01.Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  7. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial.

    Science.gov (United States)

    Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong

    2016-06-25

    The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.

  8. Balloon dilatation for the treatment of stricture of gastrojejunostomy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yeon Hwa [Lee Rha Hospital, Chungju (Korea, Republic of); Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Han, Young Min; Chon, Su Bin; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul [Chonbuk National University College of Medicine, Chungju (Korea, Republic of)

    1993-07-15

    Enteroenteric anastomotic strictures of UGI tract are common and require treatment if significant obstruction occurs. We performed fluoroscopic guided balloon dilatation in 6 patients who had symptomatic stricture of gastrojejunostomy. The stricture was successfully resolved in 4 patients with benign stricture. But 2 patients with malignant stricture had recurrence of obstructive symptoms 2 weeks later, and they required a stent. Asymptomatic balloon rupture was seen in one patients, but other procedural complications did not occur. We found that fluoroscopic guided balloon dilatation is an effective and safe method in the treatment of anastomotic stricture of gastrojejunostomy. We also found transient effect in malignant gastrojejunal anastomotic strictures, which required an interventional procedure, such as placement of a stent.

  9. US Daily Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Pilot Balloon observational forms for the United States. Taken by Weather Bureau and U.S. Army observers. Period of record 1918-1960. Records scanned from the NCDC...

  10. Stability analysis and trend study of a balloon tethered in a wind, with experimental comparisons

    Science.gov (United States)

    Redd, L. T.; Bland, S. R.; Bennett, R. M.

    1973-01-01

    A stability analysis and trend study for a balloon tethered in a steady wind are presented. The linearized, stability-derivative type analysis includes balloon aerodynamics, buoyancy, mass (including apparent mass), and static forces resulting from the tether cable. The analysis has been applied to a balloon 7.64 m in length, and the results are compared with those from tow tests of this balloon. This comparison shows that the analysis gives reasonable predictions for the damping, frequencies, modes of motion, and stability boundaries exhibited by the balloon. A trend study for the 7.64-m balloon was made to illustrate how the stability boundaries are affected by changes in individual stability parameters. The trends indicated in this study may also be applicable to many other tethered-balloon systems.

  11. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    This paper presents a study of pumpkin-shaped superpressure balloons consisting of gores made from a thin polymeric film attached to high stiffness meridional tendons This type of design is being used for the NASA ULDB balloons The gore film shows considerable time-dependent stress relaxation whereas the behaviour of the tendons is essentially time-independent Upon inflation and pressurization the instantaneous i e linear-elastic strain and stress distributions in the film show significantly higher values in the meridional direction However over time and due to the biaxial visco-elastic stress relaxation of the the gore material the em hoop strains increase and the em meridional stresses decrease whereas the em remaining strain and stress components remain substantially unchanged These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission both in terms of the material performance and the overall stability of the shape of the balloon An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter 48 gore pumpkin balloon is presented The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature The results show good correlation with a numerical study using the ABAQUS finite-element package that includes a widely used model of

  12. Clinical Study of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for Severe Pelvic Fracture and Intra Abdominal Hemorrhagic Shock using Continuous Vital Signs

    Science.gov (United States)

    2016-03-01

    aorta extending from the lowest renal artery to the aortic bifurcation. Despite the anatomic plausibility of Stannard’s technical description, it is...resuscitative thoracotomy. Zone II is the paravisceral segment and was proposed as a potential no-occlusion zone, while Zone III represents the infra- renal ...not a clinical report, simply an anatomic recommendation based on zones of aortic perfusion. The rationale behind REBOA follows the understanding

  13. Fasting and meal-induced CCK and PP secretion following intragastric balloon treatment for obesity.

    Science.gov (United States)

    Mathus-Vliegen, Elisabeth M H; de Groot, Gerrit H

    2013-05-01

    Satiety is centrally and peripherally mediated by gastrointestinal peptides and the vagal nerve. We aimed to investigate whether intragastric balloon treatment affects satiety through effects on fasting and meal-stimulated cholecystokinin (CCK) and pancreatic polypeptide (PP) secretion. Patients referred for obesity treatment were randomised to 13 weeks of sham treatment followed by 13 weeks of balloon treatment (group 1; sham/balloon) or to twice a 13-week period of balloon treatment (group 2; balloon/balloon). Blood samples were taken for fasting and meal-stimulated CCK and PP levels at the start (T0) and after 13 (T1) and 26 (T2) weeks. Patients filled out visual analogue scales (VAS) to assess satiety. Forty-two patients (35 females, body weight 125.1 kg, BMI 43.3 kg/m(2)) participated. In group 1, basal CCK levels decreased but meal-stimulated response remained unchanged after 13 weeks of sham treatment. In group 2, basal and meal-stimulated CCK levels decreased after 13 weeks of balloon treatment. At the end of the second 13-week period, when group 1 had their first balloon treatment, they duplicated the initial 13-week results of group 2, whereas group 2 continued their balloon treatment and reduced meal-stimulated CCK release. Both groups showed reduced meal-stimulated PP secretions at T1 and T2 compared to T0. Changes in diet composition and VAS scores were similar. Improvements in glucose homeostasis partly explained the PP results. The reduced CCK and PP secretion after balloon positioning was unexpected and may reflect delayed gastric emptying induced by the balloon. Improved glucose metabolism partly explained the reduced PP secretion. Satiety and weight loss were not adversely influenced by these hormonal changes.

  14. Part-time occlusion therapy for amblyopia in older children

    Directory of Open Access Journals (Sweden)

    Singh Inderpreet

    2008-01-01

    Full Text Available Aim: To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Materials and Methods: Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57, strabismic (25 and mixed (18 unilateral amblyopia were randomized (simple randomization into four groups (25 each to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Statistical Analysis: Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. Results: All four groups showed significant visual improvement after 18 weeks of occlusion therapy ( P < 0.001. Seventy-three (73% of the total 100 eyes responded to amblyopia therapy with 11 eyes (44%, 17 eyes (68%, 22 eyes (88% and 23 eyes (92% being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80, there was no significant difference in visual outcome among the four groups ( P =0.083. However, in severe amblyopia (vision 20/100 or worse, six hours ( P =0.048 and full-time occlusion ( P =0.027 treatment were significantly more effective than two hours occlusion. Conclusion: All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy.

  15. Balloon dilation of congenital supravalvular pulmonic stenosis in a dog.

    Science.gov (United States)

    Treseder, Julia R; Jung, SeungWoo

    2017-03-30

    Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a case of supravalvular pulmonic stenosis diagnosed echocardiographically and angiographically in which a significant reduction in pressure gradient was achieved with balloon dilation alone is presented.

  16. [Occlusal anomalies in the deciduous and mixed bites].

    Science.gov (United States)

    Legovic, M; Mady, L

    1998-01-01

    In 311 examines (177 boys and 134 girls) with primary dentition and 535 examinees (285 boys and 250 girls) with mixed dentition in Istria--Croatia, the frequency of orthodontic and occlusive anomalies in regard of space plane and premature extraction of c, m1 and m2 are investigated. The orthodontic anomalies are defected in 46.95%, premature loss in 11.25% and occlusive anomalies in 40.85% of examinees with primary dentition, while in mixed dentition the 58.69% of examinees have orthodontic anomaly, the 17.20% premature loss and the 48.97% of examinees have occlusal anomaly. In both phases of dentition the most frequent are occlusive anomalies in the following planes: sagittal, vertical and sagittal-vertical.

  17. Occlusal plane location in edentulous patients: a review.

    Science.gov (United States)

    Shetty, Sanath; Zargar, Nazia Majeed; Shenoy, Kamalakanth; Rekha, V

    2013-09-01

    Occlusal plane orientation is an important factor in the construction of a complete denture. Occlusal plane could be oriented using landmarks in the mandibular arch as well as in the maxillary arch. In the mandibular arch there are few landmarks which could be used to orient the occlusal plane like the retromolar pad, corner of the lips (lower lip length) whereas the maxillary arch has a number of landmarks, of which the ala-tragal line is the most commonly used and the same being the most controversial. In the following article different landmarks and its accuracy for orientating the occlusal plane in an edentulous subject as studied by various authors has been discussed.

  18. Titan Balloon Convection Model, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  19. [Study on retention and stability of linear occlusal complete dentures].

    Science.gov (United States)

    Zhang, Ping; Xu, Jun

    2003-01-01

    To learn retention and stability of linear occlusal complete dentures by investigating the subjective feelings of patient and the value of retention force. Static retention forces of maxillary and mandibular dentures were measured for 25 patients wearing linear occlusal dentures by using Hz-1 retention dynamometer. The subjective feelings of patients in functional state were gained simultaneously through questionnaire. Linear occlusal dentures demonstrate good retention in static and dynamic state. Among patients with severe resorption of residual ridge (RRR), mandibular linear occlusal dentures (shown good retentive subjective feelings) demonstrate significantly smaller retention force than those with slight or medium degree of RRR. There is no correlation between the subjective feelings and the values of retention forces of mandibular dentures. The subjective feelings of patients wearing new linear occlusal dentures are much better than that of old anatomic occlusal dentures. Linear occlusal dentures improve the performances of dentures by enhancing their stability during mastication movement.

  20. A randomised comparison of Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion: rationale and design of the CIT-RESOLVE trial.

    Science.gov (United States)

    Zhang, Dong; Yin, Dong; Song, Chenxi; Zhu, Chengang; Kirtane, Ajay J; Xu, Bo; Dou, Kefei

    2017-06-12

    The intentional strategy (aggressive side branch (SB) protection strategy: elective two-stent strategy or jailed balloon technique) is thought to be associated with lower SB occlusion rate than conventional strategy (provisional two-stent strategy or jailed wire technique). However, most previous studies showed comparable outcomes between the two strategies, probably due to no risk classification of SB occlusion when enrolling patients. There is still no randomised trial compared the intentional and conventional strategy when treating bifurcation lesions with high risk of SB occlusion. We aim to investigate if intentional strategy is associated with significant reduction of SB occlusion rate compared with conventional strategy in high-risk patients. The Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion (CIT-RESOLVE) is a prospective, randomised, single-blind, multicentre clinical trial comparing the rate of SB occlusion between the intentional strategy group and the conventional strategy group (positive control group) in a consecutive cohort of patients with high risk of side branch occlusion defined by V-RESOLVE score, which is a validated angiographic scoring system to evaluate the risk of SB occlusion in bifurcation intervention and used as one of the inclusion criteria to select patients with high SB occlusion risk (V-RESOLVE score ≥12). A total of 21 hospitals from 10 provinces in China participated in the present study. 566 patients meeting all inclusion/exclusion criteria are randomised to either intentional strategy group or conventional strategy group. The primary endpoint is SB occlusion (defined as any decrease in thrombolysis in myocardial infarction flow grade or absence of flow in SB after main vessel stenting). All patients are followed up for 12-month postdischarge. The protocol has been approved by all local ethics committee. The ethics committee have

  1. Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Jambon, E.; Petitpierre, F. [Pellegrin Hospital, Department of Radiology (France); Brizzi, V.; Dubuisson, V. [Pellegrin Hospital, Department of Surgery (France); Bras, Y. Le; Grenier, N.; Cornelis, F., E-mail: cornelisfrancois@gmail.com [Pellegrin Hospital, Department of Radiology (France)

    2017-02-15

    PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

  2. Experimental occlusal interference induces long-term masticatory muscle hyperalgesia in rats.

    Science.gov (United States)

    Cao, Ye; Xie, Qiu-Fei; Li, Kai; Light, Alan R; Fu, Kai-Yuan

    2009-08-01

    Temporomandibular joint or related masticatory muscle pain represents the most common chronic orofacial pain condition. Patients frequently report this kind of pain after dental alterations in occlusion. However, lack of understanding of the mechanisms of occlusion-related temporomandibular joint and muscle pain prevents treating this problem successfully. To explore the relationship between improper occlusion (occlusal interference) and masticatory muscle pain, we created an occlusal interference animal model by directly bonding a crown to a maxillary molar to raise the masticating surface of the tooth in rats. We raised the occlusal surface to three different heights (0.2, 0.4, and 0.6mm), and for one month we quantitatively measured mechanical nociceptive thresholds of the temporal and masseter muscles on both sides. Results showed a stimulus-response relationship between the height of occlusal interference and muscle hyperalgesia. Removal of the crown 6 days after occlusal interference showed that the removal at this time could not terminate the 1 month duration of mechanical hyperalgesia in the masticatory muscles. Lastly, we systemically administered NMDA antagonist MK801 (0.2, 0.1, and 0.05 mg/kg) to the treated rats and found that MK801 dose dependently attenuated the occlusal interference-induced hyperalgesia. These findings suggest that occlusal interference is directly related to masticatory muscle pain, and that central sensitization mechanisms are involved in the maintenance of the occlusal interference-induced mechanical hyperalgesia.

  3. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    International Nuclear Information System (INIS)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Young Wook; Kim, Dong Ik

    2011-01-01

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  4. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, R., E-mail: iezzir@virgilio.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Di Stasi, C.; Simeone, A.; Bonomo, L. [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy)

    2011-07-15

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  5. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    International Nuclear Information System (INIS)

    Iezzi, R.; Di Stasi, C.; Simeone, A.; Bonomo, L.

    2011-01-01

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  6. Collation of chewing efficiency and dentures with diverse occlusal schemes

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Peddinti

    2017-01-01

    Full Text Available Background: Rehabilitation of an edentulous patient nurtures satisfaction and this lies in the chewing ability provided by the prosthesis. Aim: To evaluate and compare the masticatory efficiencies of complete dentures with different occlusal schemes. Materials and Methods: Fourteen completely edentulous patients from the age group of 50-70 years were selected according to the inclusion criteria followed in this study. The dentures were made with three different occlusal schemes, i.e., anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion and stored in water till the date of denture insertion. Post-insertion instructions were given to the patients at the time of delivery of the dentures. Patients were recalled after seven days and then masticatory efficiency was performed. The test was performed using boiled peanuts and Sieve system. Statistical Analysis: One-way analysis of variance (ANOVA test and unpaired t-test were carried out. Results: The obtained masticatory efficiency values with anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion LO were analyzed using one-way ANOVA test and unpaired “t” test. The tests showed that lingualized scheme had highest masticatory efficiency. Conclusion: Within the scope of this study, it can be concluded that the masticatory efficiency will be generally higher in patients provided with complete dentures fabricated using the lingualized occlusal scheme.

  7. Compliance with occlusion therapy for childhood amblyopia.

    Science.gov (United States)

    Wallace, Michael P; Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2013-09-17

    Explore compliance with occlusion treatment of amblyopia in the Monitored and Randomized Occlusion Treatment of Amblyopia Studies (MOTAS and ROTAS), using objective monitoring. Both studies had a three-phase protocol: initial assessment, refractive adaptation, and occlusion. In the occlusion phase, participants were instructed to dose for 6 hours/day (MOTAS) or randomized to 6 or 12 hour/day (ROTAS). Dose was monitored continuously using an occlusion dose monitor (ODM). One hundred and fifty-two patients (71 male, 81 female; 122 Caucasian, 30 non-Caucasian) of mean ± SD age 68 ± 18 months participated. Amblyopia was defined as an interocular acuity difference of at least 0.1 logMAR and was associated with anisometropia in 50, strabismus in 44, and both (mixed) in 58. Median duration of occlusion was 99 days (interquartile range 72 days). Mean compliance was 44%, mean proportion of days with no patch worn was 42%. Compliance was lower (39%) on weekends compared with weekdays (46%, P = 0.04), as was the likelihood of dosing at all (52% vs. 60%, P = 0.028). Compliance was lower when attendance was less frequent (P amblyopia type, and severity were not associated with compliance. Mixture modeling suggested three subpopulations of patch day doses: less than 30 minutes; doses that achieve 30% to 80% compliance; and doses that achieve around 100% compliance. This study shows that compliance with patching treatment averages less than 50% and is influenced by several factors. A greater understanding of these influences should improve treatment outcome. (ClinicalTrials.gov number, NCT00274664).

  8. Single-centre comparison of a novel single-step balloon inflation ...

    African Journals Online (AJOL)

    Objective. A new second-generation balloon dilatation device for percutaneous nephrolithotomy (PCNL) has been launched, promising to challenge the traditional Amplatz serial dilators (ASDs). This device allows for the polyurethane sheath to be deployed on balloon inflation. Our primary objective in this pilot study was to ...

  9. Modeling the ascent of sounding balloons: derivation of the vertical air motion

    Directory of Open Access Journals (Sweden)

    A. Gallice

    2011-10-01

    Full Text Available A new model to describe the ascent of sounding balloons in the troposphere and lower stratosphere (up to ∼30–35 km altitude is presented. Contrary to previous models, detailed account is taken of both the variation of the drag coefficient with altitude and the heat imbalance between the balloon and the atmosphere. To compensate for the lack of data on the drag coefficient of sounding balloons, a reference curve for the relationship between drag coefficient and Reynolds number is derived from a dataset of flights launched during the Lindenberg Upper Air Methods Intercomparisons (LUAMI campaign. The transfer of heat from the surrounding air into the balloon is accounted for by solving the radial heat diffusion equation inside the balloon. In its present state, the model does not account for solar radiation, i.e. it is only able to describe the ascent of balloons during the night. It could however be adapted to also represent daytime soundings, with solar radiation modeled as a diffusive process. The potential applications of the model include the forecast of the trajectory of sounding balloons, which can be used to increase the accuracy of the match technique, and the derivation of the air vertical velocity. The latter is obtained by subtracting the ascent rate of the balloon in still air calculated by the model from the actual ascent rate. This technique is shown to provide an approximation for the vertical air motion with an uncertainty error of 0.5 m s−1 in the troposphere and 0.2 m s−1 in the stratosphere. An example of extraction of the air vertical velocity is provided in this paper. We show that the air vertical velocities derived from the balloon soundings in this paper are in general agreement with small-scale atmospheric velocity fluctuations related to gravity waves, mechanical turbulence, or other small-scale air motions measured during the SUCCESS campaign (Subsonic Aircraft: Contrail and Cloud Effects

  10. High Altitude Balloons as a Platform for Space Radiation Belt Science

    Science.gov (United States)

    Mazzino, L.; Buttenschoen, A.; Farr, Q.; Hodgson, C.; Johnson, W.; Mann, I. R.; Rae, J.; University of Alberta High Altitude Balloons (UA-HAB)

    2011-12-01

    The goals of the University of Alberta High Altitude Balloons Program (UA-HAB) are to i) use low cost balloons to address space radiation science, and ii) to utilise the excitement of "space mission" involvement to promote and facilitate the recruitment of undergraduate and graduate students in physics, engineering, and atmospheric sciences to pursue careers in space science and engineering. The University of Alberta High Altitude Balloons (UA-HAB) is a unique opportunity for University of Alberta students (undergraduate and graduate) to engage in the hands-on design, development, build, test and flight of a payload to operate on a high altitude balloon at around 30km altitude. The program development, including formal design and acceptance tests, reports and reviews, mirror those required in the development of an orbital satellite mission. This enables the students to gain a unique insight into how space missions are flown. UA-HAB is a one and half year program that offers a gateway into a high-altitude balloon mission through hands on experience, and builds skills for students who may be attracted to participate in future space missions in their careers. This early education will provide students with the experience necessary to better assess opportunities for pursuing a career in space science. Balloons offer a low-cost alternative to other suborbital platforms which can be used to address radiation belt science goals. In particular, the participants of this program have written grant proposal to secure funds for this project, have launched several 'weather balloon missions', and have designed, built, tested, and launched their particle detector called "Maple Leaf Particle Detector". This detector was focussed on monitoring cosmic rays and space radiation using shielded Geiger tubes, and was flown as one of the payloads from the institutions participating in the High Altitude Student Platform (HASP), organized by the Louisiana State University and the Louisiana

  11. Object tracking by occlusion detection via structured sparse learning

    KAUST Repository

    Zhang, Tianzhu

    2013-06-01

    Sparse representation based methods have recently drawn much attention in visual tracking due to good performance against illumination variation and occlusion. They assume the errors caused by image variations can be modeled as pixel-wise sparse. However, in many practical scenarios these errors are not truly pixel-wise sparse but rather sparsely distributed in a structured way. In fact, pixels in error constitute contiguous regions within the object\\'s track. This is the case when significant occlusion occurs. To accommodate for non-sparse occlusion in a given frame, we assume that occlusion detected in previous frames can be propagated to the current one. This propagated information determines which pixels will contribute to the sparse representation of the current track. In other words, pixels that were detected as part of an occlusion in the previous frame will be removed from the target representation process. As such, this paper proposes a novel tracking algorithm that models and detects occlusion through structured sparse learning. We test our tracker on challenging benchmark sequences, such as sports videos, which involve heavy occlusion, drastic illumination changes, and large pose variations. Experimental results show that our tracker consistently outperforms the state-of-the-art. © 2013 IEEE.

  12. Long duration balloon flights in the middle stratosphere

    Science.gov (United States)

    Malaterre, P.

    1993-02-01

    Research and development performed by the French Space Agency (CNES) over the past 10 years has given the scientific community the Infrared Montgolfiere, a balloon capable of lifting 50-kg payloads into the stratosphere for periods of several weeks. The Infrared Montgolfiere is a hot air balloon that captures infrared radiation using the earth as a heat source. Thirty flights have been launched so far, some lasting more than sixty days and circling the globe twice.

  13. Mesenteric vascular occlusion: Comparison of ancillary CT findings between arterial and venous occlusions and independent CT findings suggesting life-threatening events

    International Nuclear Information System (INIS)

    Wong, Yon Cheong; Wu, Cheng Hsien; Wang, Li Jen; Chen, Huan Wu; Lin, Being Chuan; Huang, Chen Chih

    2013-01-01

    To compare the ancillary CT findings between superior mesenteric artery thromboembolism (SMAT) and superior mesenteric vein thrombosis (SMVT), and to determine the independent CT findings of life-threatening mesenteric occlusion. Our study was approved by the institution review board. We included 43 patients (21 SMAT and 22 SMVT between 1999 and 2008) of their median age of 60.0 years, and retrospectively analyzed their CT scans. Medical records were reviewed for demographics, management, surgical pathology diagnosis, and outcome. We compared CT findings between SMAT and SMVT groups. Multivariate analysis was conducted to determine the independent CT findings of life-threatening mesenteric occlusion. Of 43 patients, 24 had life-threatening mesenteric occlusion. Death related to mesenteric occlusion was 32.6%. A thick bowel wall (p < 0.001), mesenteric edema (p < 0.001), and ascites (p = 0.009) were more frequently associated with SMVT, whereas diminished bowel enhancement (p = 0.003) and paralytic ileus (p = 0.039) were more frequent in SMAT. Diminished bowel enhancement (OR = 20; p = 0.007) and paralytic ileus (OR = 16; p = 0.033) were independent findings suggesting life-threatening mesenteric occlusion. The ancillary CT findings occur with different frequencies in SMAT and SMVT. However, the independent findings indicating life-threatening mesenteric occlusion are diminished bowel wall enhancement and paralytic ileus.

  14. Use of Cutting Balloon in the Treatment of Urethral Stricture: A Novel Technique

    International Nuclear Information System (INIS)

    Yildirim, Erkan; Cicek, Tufan; Istanbulluoglu, Okan; Ozturk, Bulent

    2009-01-01

    The peripheral cutting balloon has been used to treat various nonvascular strictures as well as vascular stenosis. In this article, we describe for the first time the use of the cutting balloon in the treatment of patients with urethral stricture. Four patients with bulbar urethral stricture were included in the study. All strictures were successfully dilated with the cutting balloon, and patients were free of symptoms at 6-month follow-up. Cutting-balloon dilatation is a safe, easy-to-perform, and effective treatment for patients with tight urethral strictures.

  15. Viscoresistive g-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Paris, R.B.

    1980-01-01

    The resistive G-mode and its particular form, the resistive ballooning mode, are treated as limits of a single simple model. MHD theory including parallel and perpendicular viscosity, finite shear, and finite beta is employed to study their linear stability

  16. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  17. Safety and effectiveness of gastric balloons associated with hypocaloric diet for the treatment of obesity.

    Science.gov (United States)

    de Castro, Maria Luisa; Morales, Maria Jose; Martínez-Olmos, Miguel A; Pineda, Juan R; Cid, Lucia; Estévez, Pamela; del-Campo, Victor; Rodríguez-Prada, J Ignacio

    2013-10-01

    intragastric balloons provide early satiety and thereby induce short-term weight loss. The aim of this study was to evaluate safety and short and medium-term effectiveness of gastric balloons associated to hypocaloric diet in obesity. from May 2004 to June 2011 91 obese patients, body mass index (BMI) 45.2 +/- 7.2 kg/m2 were prospectively followed after endoscopic implantation of a gastric balloon associated to restricted diet. Successful therapy was defined as percent loss of total weight (%LTW) > or = 5 % at six months after balloon placement and 6 and 12 months after their withdrawal. All analyses followed intention-to treat principles considering significant p-values or = 5 %. Short-term and medium-term effectiveness was negatively associated to obesity in first-grade relatives (p = 0.003 and p = 0.04). Higher weight loss 6 months after balloon placement independently predicted medium-term effectiveness (p = 0.0001). Mortality was absent but there were two spontaneous deflations of air-filled balloons and severe withdrawal difficulties in 8 patients, leading to surgery in one case. Retrieval complications associated to air-filled balloons (p = 0.0005). in obesity, effectiveness of gastric balloons associated to hypocaloric diet decreases over time.Complications occurred mainly in the retrieval endoscopic procedure and related to air-filled balloons.

  18. EUSO-BALLOON a pathfinder for detecting UHECR's from the edge of space

    Directory of Open Access Journals (Sweden)

    Scotti V.

    2013-06-01

    Full Text Available EUSO-Balloon has been conceived as a pathfinder mission for JEM-EUSO, to perform an end-to-end test of the subsystems and components, and to prove the global detection chain while improving our knowledge of the atmospheric and terrestrial UV background. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-BALLOON will serve as an evolutive test-bench for all the key technologies of JEM-EUSO. EUSO-Balloon also has the potential to detect Extensive Air Showers from above, marking a key milestone in the development of UHECR science, and paving the way for any future large scale, space-based UHECR observatory.

  19. Balloon-borne stratospheric BrO measurements: comparison with Envisat/SCIAMACHY BrO limb profiles

    Directory of Open Access Journals (Sweden)

    M. Dorf

    2006-01-01

    Full Text Available For the first time, results of four stratospheric BrO profiling instruments, are presented and compared with reference to the SLIMCAT 3-dimensional chemical transport model (3-D CTM. Model calculations are used to infer a BrO profile validation set, measured by 3 different balloon sensors, for the new Envisat/SCIAMACHY (ENVIronment SATellite/SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY satellite instrument. The balloon observations include (a balloon-borne in situ resonance fluorescence detection of BrO (Triple, (b balloon-borne solar occultation DOAS measurements (Differential Optical Absorption Spectroscopy of BrO in the UV, and (c BrO profiling from the solar occultation SAOZ (Systeme d'Analyse par Observation Zenithale balloon instrument. Since stratospheric BrO is subject to considerable diurnal variation and none of the measurements are performed close enough in time and space for a direct comparison, all balloon observations are considered with reference to outputs from the 3-D CTM. The referencing is performed by forward and backward air mass trajectory calculations to match the balloon with the satellite observations. The diurnal variation of BrO is considered by 1-D photochemical model calculation along the trajectories. The 1-D photochemical model is initialised with output data of the 3-D model with additional constraints on the vertical transport, the total amount and photochemistry of stratospheric bromine as given by the various balloon observations. Total [Bry]=(20.1±2.5 pptv obtained from DOAS BrO observations at mid-latitudes in 2003, serves as an upper limit of the comparison. Most of the balloon observations agree with the photochemical model predictions within their given error estimates. First retrieval exercises of BrO limb profiling from the SCIAMACHY satellite instrument on average agree to around 20% with the photochemically-corrected balloon observations of the remote sensing instruments (SAOZ

  20. Endoscopic minor papilla balloon dilation for the treatment of symptomatic pancreas divisum.

    Science.gov (United States)

    Yamamoto, Natsuyo; Isayama, Hiroyuki; Sasahira, Naoki; Tsujino, Takeshi; Nakai, Yousuke; Miyabayashi, Koji; Mizuno, Suguru; Kogure, Hirofumi; Sasaki, Takashi; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2014-08-01

    A subpopulation of patients with pancreas divisum experience symptomatic events such as recurrent acute pancreatitis and chronic pancreatitis. Minor papilla sphincterotomy has been reported as being an effective treatment. The aim of this study was to evaluate the safety and efficacy of endoscopic balloon dilation for the minor papilla. Between 2000 and 2012, 16 patients were retrospectively included in this study. After endoscopic balloon dilation for the minor papilla was received, a pancreatic stent or a nasal pancreatic drainage catheter was placed for 1 week. If a stricture or obstruction was evident, it was treated with balloon dilation followed by long-term stent placement (1 year). When an outflow of pancreatic juice was disturbed by a pancreatic stone, endoscopic stone extraction was performed. Balloon dilation and stent placement were achieved and were successful in all the cases (16/16; 100%). Clinical improvement was achieved in 7 (84.7%) of the 9 patients with recurrent acute pancreatitis and in 6 (85.7%) of the 7 patients with chronic pancreatitis. Early complications were observed in 1 (6.3%) patient. Pancreatitis or bleeding related to balloon dilation was not observed. Endoscopic balloon dilation for the minor papilla is feasible for the management of symptomatic pancreas divisum.

  1. Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography.

    LENUS (Irish Health Repository)

    Manning, Brian J

    2012-02-01

    OBJECTIVES: Cumulative radiation dose, cost, and increased demand for computed tomography aortography (CTA) suggest that duplex ultrasonography (DU) may be an alternative to CTA-based surveillance. We compared CTA with DU during endovascular aneurysm repair (EVAR) follow-up. METHODS: Patients undergoing EVAR had clinical and radiological follow-up data entered in a prospectively maintained database. For the purpose of this study, the gold standard test for endoleak detection was CTA, and an endoleak detected on DU alone was assumed to be a false positive result. DU interpretation was performed independently of CTA and vice versa. RESULTS: One hundred thirty-two patients underwent EVAR, of whom 117 attended for follow-up ranging from six months to nine years (mean, 32 months). Adequate aneurysm sac visualisation on DU was not possible in 1.7% of patients, predominantly due to obesity. Twenty-eight endoleaks were detected in 28 patients during follow-up. Of these, 24 were initially identified on DU (four false negative DU examinations), and eight had at least one negative CTA with a positive DU prior to diagnosis. Twenty-three endoleaks were type II in nature and three of these patients had increased sac size. There was one type I and four type III endoleaks. Two of these (both type III) had an increased sac size. Of 12 patients with increased aneurysm size of 5 mm or more at follow-up, five had an endoleak visible on DU, yet negative CTA and a further five had endoleak visualisation on both DU and CTA. Of six endoleaks which underwent re-intervention, all were initially picked up on DU. One of these endoleaks was never demonstrated on CTA and a further two had at least one negative CTA prior to endoleak confirmation. Positive predictive value for DU was 45% and negative predictive value 94%. Specificity of DU for endoleak detection was 67% when compared with CTA, because of the large number of false positive DU results. Sensitivity for DU was 86%, with all

  2. Severe Sunburn After a Hot Air Balloon Ride: A Case Report and Literature Review.

    Science.gov (United States)

    Ozturk, Sinan; Karagoz, Huseyin

    2015-01-01

    Hot air balloon tours are very popular among travelers worldwide. Preventable burn injuries associated with hot air balloon rides have been reported during crashes into power lines, in propane burner explosions, and following contact with the propane burner tanks. We present a case of severe repeated sunburn, which poses another risk of preventable injury during hot air balloon rides, and briefly discuss the injury epidemiology of hot air balloon rides. © 2015 International Society of Travel Medicine.

  3. The Micro-Instrumentation Package: A Solution to Lightweight Ballooning

    Science.gov (United States)

    Juneau, Jill

    This paper discusses the design and testing of an over the horizon (OTH) light weight telemetry and termination system that can be used for small ballooning payloads. Currently, the Columbia Scientific Balloon Facility (CSBF) provides telemetry for the science payload by integrating one of two types of support packages. The type of support package integrated depends on whether the flight will stay in range of line of sight (LOS) or will exceed LOS requiring the use of over the horizon (OTH) telemetry. The weights of these systems range from 100 pounds to 350 pounds depending upon the use of redundant systems, equipment for high data rates, and batteries and/or solar panels for power requirements. These weight values are not as significant for larger payloads but can be crippling for smaller payloads. In addition, these support package systems are fairly expensive, placing a high importance on recovery. A lightweight and inexpensive telemetry system could be beneficial for various reasons. First, it would allow scientists to fly lightweight payloads on large balloons reaching even higher altitudes. Second, scientists could fly lightweight payloads on less expensive balloons such as meteorological balloons. Depending on the payload, these flights could be fairly inexpensive and even disposable. Third, a compact telemetry system on any balloon will free up more room for the science portion of the payload. In response, a compact telemetry/termination system called the Micro-Instrumentation Package (MIP) was developed. The MIP provides uplink and downlink communications, an interface to the science, housekeeping information including global positioning system (GPS) position, and relays. Instead of a power-hungry microprocessor, the MIP's central consists of a microcontroller. Microcontrollers are lower power, easily programmed, and can be purchased for less than ten dollars. For uplink and downlink telemetry, the MIP uses an LOS serial transceiver and an Iridium unit

  4. Balloon catheter dilatation of esophageal strictures in children and an infant

    International Nuclear Information System (INIS)

    Yeon, Kyung Mo; Choe, Yeon Hyeon; Kim, In One

    1986-01-01

    Severe postoperative strictures in two children and an infant and mild postoperative stricture in a child were treated with balloon catheter. A child with post-fundoplication stricture showed symptomatic improvement. Anastomotic strictures after esophageal atresia repair in an infant and a child were successfully dilated with improved luminal diameter and symptoms. In a child with mild postoperative stricture, balloon dilatation was performed to prevent stricture of the anastomotic site. Radiological esophageal dilatation using balloon catheters is a safe effective method for dilating symptomatic esophageal strictures which obviates surgery and allows subsequent standard bougienage.

  5. High n ballooning modes in highly elongated tokamaks

    International Nuclear Information System (INIS)

    An, C.H.; Bateman, G.

    1980-02-01

    An analytic study of stability against high n ballooning modes in highly elongated axisymmetric plasmas is presented and compared with computational results. From the equation for the marginal pressure gradient, it is found that the local shear plays an important role on the stability of elongated and shifted plasma, and that high elongation deteriorates the stability by decreasing the stabilizing effects of field line bending and local shear. The net contribution of the local shear to stability decreases with elongation and shift for strongly ballooning modes (eigenfunctions strongly localized near the outer edge of the toroidal flux surfaces) but increases for interchange modes (eigenfunctions more uniform along the flux surfaces). The computational study of high n ballooning modes in a highly elongated plasma reveals that lowering the aspect ratio and broadening the pressure profile enhance the marginal beta for β/sub p/ less than unity but severely reduce the marginal beta for β/sub p/ larger than unity

  6. Malignant Esophagogastric Junction Obstruction: Efficacy of Balloon Dilation Combined with Chemotherapy and/or Radiation Therapy

    International Nuclear Information System (INIS)

    Ko, Gi-Young; Song, Ho-Young; Hong, Heuk-Jin; Sung, Kyu-Bo; Seo, Tae-Seok; Yoon, Hyun-Ki

    2003-01-01

    Purpose: To assess the efficacy of balloon dilation combined with chemotherapy and/or radiation therapy for palliation of dysphagia due to malignant esophagogastric junction strictures. Methods: Fluoroscopically guided balloon dilation was attempted in 20 patients. The causes of strictures were gastric adenocarcinoma (n = 10) and esophageal squamous cell carcinoma (n = 10). Scheduled chemotherapy and/or radiation therapy followed balloon dilation in all patients. Results: There were no technical failures or major complications. After balloon dilation, 15 (75%) patients showed improvement of dysphagia. No patient complained of reflux esophagitis during the follow-up period. Among the 15 patients, seven needed no further treatment for palliation of dysphagia until their deaths. The remaining eight patients underwent repeat balloon dilation(n = 4) or stent placement (n = 4)3-43 weeks (mean 15 weeks) after the initial balloon dilation because of recurrent dysphagia. Conclusion: Balloon dilation combined with chemotherapy and/or radiation therapy seems to be an easy and reasonably effective palliative treatment for malignant esophagogastric strictures

  7. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De

    1990-01-01

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  8. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  9. GRAINE balloon experiment in 2015

    Directory of Open Access Journals (Sweden)

    Rokujo Hiroki

    2017-01-01

    Full Text Available Observations of cosmic gamma rays are important for studying high energy phenomena in the universe. Since 2008, the Large Area Telescope on the Fermi satellite has surveyed the whole gamma-ray sky in the sub-GeV/GeV energy region, and accumurated a large amount of data. However, observations at the low galactic latitude remains difficult because of a lack of angular resolution, increase of background flux originating from galactic diffuse gamma rays, etc. The Gamma-Ray Astro-Imager with Nuclear Emulsion (GRAINE is a gamma-ray observation project with a new balloon-borne emulsion gamma-ray telescope. Nuclear emulsion is a high-resolution 3D tracking device. It determines the incident angle with 0.1∘ resolution for 1 GeV gamma rays (1.0∘ for 100 MeV, and has linear polarization sensitivity. GRAINE aims at precise observation of gamma-ray sources, especially in the galactic plane, by repeating long-duration balloon flights with large-aperture-area (10 m2 high-resolution emulsion telescopes. In May 2015, we performed a balloon-borne experiment in Alice Springs, Australia, in order to demonstrate the imaging performance of our telescope. The emulsion telescope that has an aperture area of 0.4 m2 was employed in this experiment. It observed the Vela pulsar (the brightest gamma-ray source in the GeV sky at an altitude of 37 km for 6 hours out of the flight duration of 14 hours. In this presentation, we will report the latest results and the status of the GRAINE project.

  10. Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Kjeldsen, Anette D

    2008-01-01

    ) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available...

  11. Preprosthetic therapy utilizing a temporary occlusal acrylic splint: a case report.

    Science.gov (United States)

    Badel, Tomislav; Kraljeviç, Sonja; Panduriç, Josip; Marotti, Miljenko

    2004-05-01

    This case report describes the complex occlusal rehabilitation of a patient with signs and symptoms of temporomandibular disorders with utilization of an occlusal acrylic splint as a means of initial treatment for neuromuscular reprogramming and repositioning of the condyle within the mandibular fossa for occlusal stability, thus allowing adaptation to a new occlusal vertical dimension.

  12. Intravitreal triamcinolone acetonide injections in the treatment of retinal vein occlusions.

    Science.gov (United States)

    Roth, Daniel B; Cukras, Catherine; Radhakrishnan, Ravi; Feuer, William J; Yarian, David L; Green, Stuart N; Wheatley, Harold M; Prenner, Jonathan

    2008-01-01

    To report the visual acuity response after intravitreal triamcinolone injection in patients with macular edema due to retinal vein occlusions. Retrospective nonrandomized interventional series of 172 consecutive patients with macular edema due to retinal vein occlusions who were treated with intravitreal triamcinolone acetonide injection. Patients underwent Snellen visual acuity testing and ophthalmoscopic examination at baseline and 1, 3, 6, and 12 months after intravitreal triamcinolone acetonide injection. All subtypes of retinal vein occlusions showed significant improvements in mean visual acuity 1 month after injection. This improvement in visual acuity was maintained over the 12-month period for all but the central retinal vein occlusion group. Seventy-one (41.3%) of the 172 patients received more than one intravitreal triamcinolone injection for unresolved or recurrent macular edema. This study demonstrates a benefit associated with intravitreal triamcinolone acetonide injection for retinal vein occlusions that was maintained by patients with branch retinal vein occlusions and hemiretinal vein occlusions over a 12-month period. Visual acuity improvement was not maintained in patients with central retinal vein occlusions with this course of treatment.

  13. Femoral artery recanalisation with percutaneous angioplasty and segmentally enclosed plasminogen activator

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Bülow, J

    1989-01-01

    To establish whether re-occlusion of the femoral artery could be prevented, in 6 consecutive patients undergoing percutaneous transluminal angioplasty (PTA) for superficial femoral artery occlusion the recanalised segment was isolated, with a 7-French double-balloon catheter. 5 mg recombined huma...

  14. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  15. Does compliance with amblyopia management improve following supervised occlusion treatment?

    Science.gov (United States)

    El-Ghrably, I A; Longville, D; Gnanaraj, L

    2007-01-01

    To demonstrate improvement in compliance following supervised occlusion therapy for amblyopia in children who had failed to respond to outpatient treatment. Retrospective review of the visual outcome of 30 children who were admitted to an ophthalmology ward for 1-day intensive supervised occlusion. These children had documented poor compliance and previously failed to respond to the outpatient occlusion treatment. During their stay a trained ophthalmology nurse educated parents regarding amblyopia and the benefits of occlusion therapy. Visual acuity (VA) of the amblyopic and fellow eyes was recorded on admission, discharge, and at each subsequent visit. The compliance was recorded from parent's history and also indirectly by noticing improvement in vision. The mean supervised occlusion was 7.4 hours (range 4-12 hours). The compliance with occlusion therapy improved in 23 children (77%) after discharge. The mean duration of occlusion after discharge improved to 4 hours (range 1-12 hours). The mean follow-up was 18 months (range 4-24 months). Though there was no dramatic improvement in VA at discharge there was a statistically significant improvement in VA between admission and last recorded VA (pocclusion following discharge, 21 (91%) gained at least one line of acuity in their amblyopic eye on the last assessment of their VA and five of them achieved 6/12. Of the seven children who did not comply with occlusion following discharge, only one patient gained one line improvement in his amblyopic eye. This study shows that supervised occlusion treatment and parental education was effective in children who had initially failed traditional outpatient treatment.

  16. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Solid State Inflation Balloon Active Deorbiter

    Data.gov (United States)

    National Aeronautics and Space Administration — The Solid State Inflation Balloon (SSIB) is a simple, reliable, low-cost, non-propulsive system for deliberate deorbit and control of downrange point-of-impact that...

  18. Isolated Liver Perfusion Using Percutaneous Methods:[ql An Experimental Study in the Pig

    International Nuclear Information System (INIS)

    Harnek, Jan; Cwikiel, Wojciech; Bergqvist, Lennart; Persson, Bo; Stridbeck, Hans

    1996-01-01

    Purpose: To develop a method for isolated perfusion of the liver using radiological methods. Methods: Twenty-one pigs, weighing about 20 kg, were divided into three groups. By transjugular and transfemoral approaches two occlusion balloons were placed in the inferior vena cava cranial and caudal, respectively, to the origin of the hepatic veins. One occlusion balloon was placed transfemorally in the common hepatic artery. Another occlusion balloon was inserted in the main branch of the portal vein via the transjugular-transhepatic approach in 11 pigs (groups 1 and 2), and in 10 pigs (group 3) by a percutaneous transhepatic route. After inflation of the balloons, patency of the isolated liver circulation was evaluated by recirculation of 99 Tc m -labelled human albumin during 30 min. Blood tests were obtained after 1, 3, 5, 10, 15, and 30 min to evaluate leakage from the liver to the systemic circulation. Results: Increasing leakage to the systemic circulation from the isolated liver circulation was observed in groups 1 and 2. In the third group the leakage was less than 10%. Conclusion: In an experimental animal model, isolated perfusion of the liver with minor leakage to the systemic circulation may be achieved using radiological methods

  19. QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALLOONING MODES

    International Nuclear Information System (INIS)

    LAO, LL; SNYDER, PB; LEONARD, AW; OSBORNE, TH; PETRIE, TW; FERRON, JR; GROEBNER, RJ; HORTON, LD; KAMADA, Y; MURAKAMI, M; OIKAWA, T; PEARLSTEIN, LD; SAARELMA, S; STJOHN, HE; THOMAS, DM; TURNBULL, AD; WILSON, HR

    2002-01-01

    OAK A271 QUANTITATIVE TESTS OF ELMS AS INTERMEDIATE N PEELING-BALLOONING MODES. Two of the major issues crucial for the design of the next generation tokamak burning plasma devices are the predictability of the edge pedestal height and control of the divertor heat load in H-mode configurations. Both of these are strongly impacted by edge localized modes (ELMs) and their size. A working model for ELMs is that they are intermediate toroidal mode number, n ∼ 5-30, peeling-ballooning modes driven by the large edge pedestal pressure gradient P(prime) and the associated large edge bootstrap current density J BS . the interplay between P(prime) and J BS as a discharge evolves can excite peeling-ballooning modes over a wide spectrum of n. The pedestal current density plays a dual role by stabilizing the high n ballooning modes via opening access to second stability but providing free energy to drive the intermediate n peeling modes. This makes a systematic evaluation of this model particularly challenging. This paper describes recent quantitative tests of this model using experimental data from the DIII-D and the JT-60U tokamaks. These tests are made possible by recent improvements to the ELITE MHD stability code, which allow an efficient evaluation of the unstable peeling-ballooning modes, as well as by improvements to other diagnostic and analysis techniques. Some of the key testable features of this model are: (1) ELMs are triggered when the growth rates of intermediate n MHD modes become significantly large; (2) ELM sizes are related to the radial widths of the unstable modes; (3) the unstable modes have a strong ballooning character localized in the outboard bad curvature region; (4) at high collisionality, ELM size generally becomes smaller because J BS is reduced

  20. Criteria for Second Stability for Ballooning Modes in Stellarators

    International Nuclear Information System (INIS)

    Hudson, S.R.; Hegna, C.C.

    2004-01-01

    An expression determining how variations in the pressure-gradient and average magnetic shear affect ballooning stability for a stellarator equilibrium is presented. The procedure for determining the marginal stability boundaries, for each field line, depends only on the equilibrium and a single ballooning eigenfunction calculation. This information is sufficient to determine if increasing pressure-gradient is stabilizing or destabilizing and to predict whether the configuration possess a second stable region