WorldWideScience

Sample records for balloon endoscope facilitates

  1. The Evaluation of Endoscopic Balloon Dilation Treatment for

    Directory of Open Access Journals (Sweden)

    Shokri-Shirvani Javad

    2009-10-01

    Full Text Available Balloon dilatation of stricture is one of the new treatment methods among patients with gastric outlet obstruction (GOO. However, the prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that would affect its success rate patients with benign etiology for GOO. Forty-five patients with the symptoms of benign GOO were randomly selected. Gastric outlet was delineated using double channel videoendoscopy. The information of initial balloon dilation was collected from recorded files. Balloon dilatation was repeated during the mean follow up of 9.9 ± 5.8 months. The severity of gastric pain was measured immediately before balloon dilatation and one month after procedure and was rated on a 10 cm visual analogue scale. The mean age of patients was 43.7 ± 18.1 years and 86.7% of them were men. Furthermore, 71.1% were H pylori positive. Response rate to endoscopic balloon dilatation was 80% and 8 patients underwent surgical resection. Weight loss was more frequent in non-responding group. The pain severity was significantly reduced more in responding subjects. No meaningful relationships were found between the responses to balloon dilatation and positive H pylori and cigarette smoking. Endoscopic balloon dilation is safe and effective for most patients with benign gastric outlet obstruction and has favorable long-term outcome.

  2. The Evaluation of Endoscopic Balloon Dilation Treatment for Benign

    Directory of Open Access Journals (Sweden)

    H. Ghofrani

    2008-04-01

    Full Text Available Background and ObjectiveBalloon dilatation of stricture is one of the new treatment methods for patients with Gastric Outlet Obstruction (GOO. Prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that could affect method advantage among patients with benign etiology for GOO. Methods Forty-five patients with symptoms of benign GOO were randomly selected. The mean age of patients was 43.7±18.1 years and 86.7% of them were men. Gastric outlet was delineated using double channel videoendoscopy. The severity of gastric pain was measured by VAS test immediately before and one month after balloon dilatation. Patients were followed after procedure weekly (for the first month and then monthly. Balloon dilatation was repeated for 27% patients during the follow up period.ResultsPatients were followed for 9.9±5.8 months. Furthermore, 71.1% were H. pylori positive. Positive response percent to endoscopic balloon dilatation was 80% and eight patients were took under surgical resection. Weight loss was seen frequently in the non-respondent group. The pain severity was significantly reduced in respondent subjects. No meaningful correlations were found between the response to balloon dilatation and positive H. pylori and cigarette smoking.ConclusionEndoscopic balloon dilatation is a safe and effective method for treating most of patients with benign gastric outlet obstruction and has favorable long-term outcome. Keywords: Endoscopy, Gastric Outlet Obstruction (GOO, Balloon Dilatation

  3. Endoscopic balloon dilatation for Crohn's strictures of the gastrointestinal tract is feasible

    DEFF Research Database (Denmark)

    Karstensen, John Gásdal; Hendel, Jakob; Vilmann, Peter

    2012-01-01

    Despite optimized medical treatment, Crohn´s disease can cause gastrointestinal (GI) strictures, which requires surgical intervention. Lately, endoscopic balloon dilatation has been established as an alternative to surgery. In the following, we report our experiences with endoscopic dilatation...

  4. Balloon sinuplasty: a new concept in the endoscopic nasal surgery

    Directory of Open Access Journals (Sweden)

    Nogueira Júnior, João Flávio

    2008-12-01

    Full Text Available Introduction: Sinus diseases affect millions of people annually. Clinical treatment is effective in most patients, but in case of failure of this therapy the functional endoscopic surgery is currently the treatment choice for surgical treatment. The objective of the functional endoscopic surgery is to increase the aeration and drainage of the involved paranasal sinuses, which allows for the adequate functioning of the nasal mucosa mucociliary clearance. However, this method still has some limitations, mainly because it removes the nasal mucosa and bone tissue, and it may lead to physiologic alterations of the nasosinusal mucosa and cicatricial fibrosis. Many of these patients could be benefited from less invasive methods, with larger nasal mucosa preservation. Since 2006, an even less invasive procedure was remarked in our specialty: the balloon dilatation of the paranasal sinus ostia. Objective: The objective of this article is to define the concept of sinuplasty, its action mechanism, and present the necessary material for the procedures performance; to describe the techniques with the equipment in a nasosinusal endoscopic surgery simulator model and review the current literature about the indications, complications, results, and follow-up of patients submitted to this procedure. Balloon sinuplasty is safe and appears to be effective in the improvement of the quality of life of patients not responsive to conventional clinical therapy. New applications and indications for this equipment should be described and researched.

  5. Endoscopic Papillary Balloon Dilation with Large Balloon after Limited Sphincterotomy for Retrieval of Choledocholithiasis

    Science.gov (United States)

    Bang, Seungmin; Kim, Myoung Hwan; Park, Jeong Youp; Park, Seung Woo; Song, Si Young

    2006-01-01

    Endoscopic papillary balloon dilation (EBD) for choledocholithiasis is known to be comparable to endoscopic sphincterotomy (EST) especially in cases of small stones. With larger stones, EBD with conventional balloon, which have a diameter of 6-8 mm, was reported as less effective for extraction of stones. We evaluated the efficacy and complications of EBD with large balloons (10-15 mm) after limited EST for retrieval of choledocholithiasis. From February 2005, we have performed EBD with limited EST for retrieval of common bile duct (CBD) stones. The patients who admitted with hyperamylasemia and gallstone pancreatitis were excluded. In cases without CBD dilation, EPBD with 12 mm for 40 seconds was performed. And in cases with CBD dilation, we dilated the sphincters with 15 mm sized balloon for 40 seconds. Total 22 patients (11 of male) were performed EBD with limited EST for retrieval of CBD stones. The median diameter of the stones was 10 mm (5-25 mm). Ten cases had multiple stones and 6 cases periampullary diverticuli. Successful stone removal in the initial session of ERCP with EBD was accomplished in 16 patients (72.7%). And complete retrieval of bile duct stones was achieved in all patients with repeated ERCP. In the aspect of complications, any episodes of perforation, bleeding was not developed. Only one case of mild grade of post-procedural pancreatitis was noted. However, post-procedural hyperamylasemia was developed in 16 cases (68.2%). EBD with larger balloon seems to be a feasible and safe alternative technique for conventional EST in CBD stone extraction. PMID:17191309

  6. Current status of endoscopic balloon dilation for Crohn's disease

    Directory of Open Access Journals (Sweden)

    Fumihito Hirai

    2017-04-01

    Full Text Available The therapeutic target in Crohn's disease (CD has been raised to the achievement of mucosal healing. Although effective treatments that target cytokines and other molecules has been widely used for CD, intestinal strictures are still a major cause of surgery. Endoscopic balloon dilation (EBD is known to be an effective and safe intervention for intestinal strictures in CD. Since frequent intestinal resection often results in short bowel syndrome and can decrease the quality of life, EBD can help avoid surgery. EBD with a conventional colonoscope for Crohn's strictures of the colon and ileo-colonic anastomosis has established efficacy and safety. In addition, EBD using balloon-assisted enteroscopy has recently been applied for small bowel Crohn's strictures. Although the evidence is not strong, EBD may become an alternative to surgery in small bowel strictures in CD. EBD and other new methods such as self-expanding stent implantation for Crohn's strictures may be useful and safe; however, it is important to address several issues regarding these interventions and to establish a protocol for combined therapies.

  7. Endoscopic papillary balloon dilatation versus endoscopic sphincterotomy in the treatment for choledocholithiasis: a meta-analysis.

    Science.gov (United States)

    Liu, Yangyang; Su, Peizhu; Lin, Siheng; Xiao, Kun; Chen, Pingyan; An, Shengli; Zhi, Fachao; Bai, Yang

    2012-03-01

    Endoscopic papillary balloon dilatation (EPBD) and endoscopic sphincterotomy (EST) are two common nonsurgical treatments endoscopic retrograde cholangiopancreatography (ERCP) for choledocholithiasis. The aim of this study was to compare the efficacy and safety of EPBD and EST in the treatment for choledocholithiasis, confining the analysis to work reported in the last decade. The rate of overall postoperative complications was chosen as the primary outcome, and 10 other outcomes were secondary outcomes. Relative risk (RR) or Peto odds ratio (OR) were computed as the measures of pooled effects. We planned sensitivity analyses a priori for examining the change in robustness of the sensitivity to excluding studies with some inappropriate objects, technique defects or without full-text acquisition. For complete stone removal, EPBD was similar to EST (95% vs. 96%, P = 0.36) and overall postoperative complications (14.0% vs. 11.7%, P = 0.53). The incidence of post-ERCP cholangitis (2.5% vs. 1.8%, P = 0.40), basket impaction (0.9% vs. 0%, P = 0.16) and perforation (0.0% vs. 0.4%, P = 0.17) were equivalent between EPBD and EST. On the other hand, EPBD caused more post-ERCP pancreatitis (PEP) (9.4% vs. 3.3%, P stone extraction, though it requires more endoscopic mechanical lithotripsy (EML). EPBD may outweigh EST for patients with coagulopathy; however, it may cause more PEP. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

  8. Balloon catheter versus basket catheter for endoscopic bile duct stone extraction: a multicenter randomized trial.

    Science.gov (United States)

    Ishiwatari, Hirotoshi; Kawakami, Hiroshi; Hisai, Hiroyuki; Yane, Kei; Onodera, Manabu; Eto, Kazunori; Haba, Shin; Okuda, Toshinori; Ihara, Hideyuki; Kukitsu, Takehiro; Matsumoto, Ryusuke; Kitaoka, Keisuke; Sonoda, Tomoko; Hayashi, Tsuyoshi

    2016-04-01

    Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent. We therefore conducted a multicenter prospective randomized trial to compare catheter performance. We enrolled patients with a BDS diameter ≤ 10 mm and common bile duct diameter ≤ 15 mm. Participants were randomly assigned to groups that were treated with basket or balloon catheters between October 2013 and September 2014. The primary endpoint was the rate of complete clearance of the duct; the secondary endpoints were the rate and time to complete clearance in one endoscopic session. We initially enrolled 172 consecutive patients; 14 were excluded after randomization. The complete clearance rates were 92.3 % (72/78) in the balloon group and 80.0 % (64 /80) in the basket group. The difference in the rates between the two groups was 12.3 percentage points, indicating non-inferiority of the balloon method (non-inferiority limit -10 %; P < 0.001 for non-inferiority). Moreover, the balloon was superior to the basket (P = 0.037). The rate of complete clearance in one endoscopic session was 97.4 % using the balloon and 97.5 % using the basket (P = 1.00). The median times to complete clearance in one endoscopic session were 6.0 minutes (1 - 30) and 7.8 minutes (1 - 37) in the balloon and basket groups, respectively (P = 0.15). For extraction of BDSs ≤ 10 mm, complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter.University Hospital Medical Information Network Trials Registry: UMIN000011887. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Endoscopic large balloon sphincteroplasty is a useful, safe adjunct for difficult to treat choledocholithiasis.

    Science.gov (United States)

    Turner, Greg A; Ing, Andrew J; Connor, Saxon J

    2016-05-01

    The aim of this study was to assess the safety and efficacy of large balloon sphincteroplasty when used in conjunction with endoscopic biliary sphincterotomy during endoscopic retrograde cholangiopancreatography (ERCP) for therapy of choledocholithiasis. A retrospective audit of all ERCP's performed for choledocholithiasis between January 2012 and October 2013 at one institution was performed. Procedures that utilized large balloon sphincteroplasty were compared with those underwent standard endoscopic stone extraction. Outcomes including stone clearance rate for the individual procedure type, post-ERCP complications and need for surgical exploration of the bile duct were documented. A total of 346 procedures on 306 patients that met the inclusion criteria were identified. Fifty-four (15.6%) procedures included large balloon sphincteroplasty and were compared with 292 (84.4%) procedures that used standard balloon extraction techniques. Despite those patients in the large balloon sphincteroplasty group having a higher rate of previous ERCP (33.3% versus 19.5%, P = 0.031) and a larger proportion of patients with stones greater than 10 mm (40.3% versus 11.3%, P choledocholithiasis. The current study demonstrated large balloon sphincteroplasty did not result in more complications despite a tendency to being used for larger stones. © 2014 Royal Australasian College of Surgeons.

  10. Transantral, endoscopically guided balloon dilatation of the ostiomeatal complex for chronic rhinosinusitis under local anesthesia.

    Science.gov (United States)

    Stankiewicz, James; Tami, Thomas; Truitt, Theodore; Atkins, James; Liepert, Douglas; Winegar, Bradford

    2009-01-01

    A multicenter study (BREATHE I - Entellus Medical, Inc.) was performed to assess the safety and outcomes of a new, less invasive system that uses direct endoscopic visualization to facilitate balloon dilation of the maxillary sinus ostia and ethmoid infundibulum. General anesthesia was avoided in most subjects to assess feasibility of performing transantral ostial dilatation in an office setting. Subjects with chronic rhinosinusitis of the maxillary sinuses alone or maxillary and anterior ethmoid sinuses underwent baseline evaluation including CT imaging and symptom assessment using the Sino-Nasal Outcome Test (SNOT 20). Subjects underwent transantral balloon dilation and follow-up evaluation at 1 week, 3 months, and 6 months post-procedure. Thirty subjects were treated at three centers. Fifty-five of 58 maxillary ostia were successfully treated for a procedural completion rate of 94.8%. Ninety-seven percent of the procedures were completed under local anesthesia with or without minimal intravenous sedation. There were no device-related serious adverse events or unanticipated adverse device effects. The mean overall SNOT 20 score at baseline was 2.9 +/- 1.0. Mean overall SNOT 20 scores at 1-week, 3-month, and 6-month follow-up were 0.8 +/- 0.8, 0.7 +/- 0.8, and 0.8 +/- 0.9 respectively. Patency at 3-months as confirmed by CT imaging was 95.8%. These results indicate that transantral balloon dilation of the ostiomeatal complex under local anesthesia appears to be a safe technique for managing isolated maxillary or maxillary and anterior ethmoid sinusitis and can potentially be performed safely in an office setting.

  11. Nonradiation ERCP with endoscopic biliary sphincterotomy plus papillary balloon dilation for the treatment of choledocholithiasis during pregnancy.

    Science.gov (United States)

    Ersoz, Galip; Turan, Ilker; Tekin, Fatih; Ozutemiz, Omer; Tekesin, Oktay

    2016-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is currently the treatment of choice for symptomatic choledocholithiasis in pregnant patients. We aimed to present our experience with pregnant patients who underwent nonradiation ERCP and to evaluate the safety and efficacy of a new technique. A retrospective analysis of nonradiation ERCP in 22 pregnant patients with symptomatic choledocholithiasis between January 2002 and December 2013 was performed. The bile aspiration technique with wire-guided sphincterotome was used to confirm selective biliary cannulation. Transpapillary pancreatic septotomy was performed in cases with difficult biliary cannulation (n = 3). After endoscopic biliary sphincterotomy, endoscopic papillary balloon dilation was performed with a 6- or 8-mm dilation balloon in all patients to reduce the risk of recurrent cholangitis because of residual or additional stones. Stones were extracted by balloon sweeping after dilation. All patients were followed for 6 months after the ERCP procedure. Biliary cannulation was achieved in all patients. Endoscopic papillary balloon dilation was performed with a 6-mm balloon in 17 patients and an 8-mm balloon in five patients. The stones were extracted in 18 of the 22 patients by balloon sweeping, but no stones were extracted in the remaining four patients. There were two cases of mild post-ERCP pancreatitis. All patients delivered at term, and none experienced recurrence of choledocholithiasis and/or cholangitis during the 6-month follow-up. Endoscopic biliary sphincterotomy plus endoscopic papillary balloon dilation in nonradiation ERCP is a safe and effective treatment method for symptomatic choledocholithiasis during pregnancy.

  12. The Evaluation of Endoscopic Balloon Dilation Treatment for Benign Gastric Outlet Obstruction

    Directory of Open Access Journals (Sweden)

    J Sokri Shirvani

    2012-05-01

    Full Text Available

    Background and Objective

    Balloon dilatation of stricture is one of the new treatment methods for patients with Gastric Outlet Obstruction (GOO. Prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that could affect method advantage among patients with benign etiology for GOO.

     

    Methods

     Forty-five patients with symptoms of benign GOO were randomly selected. The mean age of patients was 43.7±18.1 years and 86.7% of them were men. Gastric outlet was delineated using double channel videoendoscopy. The severity of gastric pain was measured by VAS test immediately before and one month after balloon dilatation. Patients were followed after procedure weekly (for the first month and then monthly. Balloon dilatation was repeated for 27% patients during the follow up period.

     

    Results

    Patients were followed for 9.9±5.8 months. Furthermore, 71.1% were H. pylori positive. Positive response percent to endoscopic balloon dilatation was 80% and eight patients were took under surgical resection. Weight loss was seen frequently in the non-respondent group. The pain severity was significantly reduced in respondent subjects. No meaningful correlations were found between the response to balloon dilatation and positive H. pylori and cigarette smoking.

     

    Conclusion

    Endoscopic balloon dilatation is a safe and effective method for treating most of patients with benign gastric outlet obstruction and has favorable long-term outcome. 

  13. The Diagnostic Value of Endoscopic Balloon Catheter Usage for Detecting Early-Stage Primary Sclerosing Cholangitis in Endoscopic Retrograde Cholangiopancreatography: A Case Report

    Science.gov (United States)

    Ozdil, Burhan; Cosar, Arif; Kece, Can; Sandikci, Macit; Akkiz, Hikmet

    2010-01-01

    A 34-year-old woman was admitted to our clinic with abdominal pain, jaundice and pruritus. Endoscopic retrograde cholangiopancreatography was performed for cholestasis. Endoscopic retrograde cholangiopancreatography (ERCP) was judged as normal, after a standard ERCP cannula was used for the cholangiogram. However, marked canalicular irregularities were identified in cholangiography when pressurized contrast agent was administrated via balloon catheter. This cholangiographic view was thought to reveal an early-stage alteration of sclerosing cholangitis. Primary sclerosing cholangitis (PSC) is a chronic cholestatic liver disease characterized by destruction and fibrosis of the bile ducts. The diagnosis of PSC is based on typical cholangiographic findings, supported by nonspecific clinical signs and symptoms, cholestatic liver biochemical tests, and liver biopsy. Cholangiography is considered to be the gold standard for the diagnosis of PSC. The diagnosis is easy when diffuse multifocal biliary strictures, the hallmarks of the disease, resulting in a ‘beaded’ appearance on ERCP is detected. However, it may reveal a normal image in an early stage of the disease when bile duct changings are not prominent. We think that balloon catheter ERCP appears to facilitate the diagnosis of early-stage primary sclerosing cholangitis. PMID:21103219

  14. The Diagnostic Value of Endoscopic Balloon Catheter Usage for Detecting Early-Stage Primary Sclerosing Cholangitis in Endoscopic Retrograde Cholangiopancreatography:A Case Report

    Directory of Open Access Journals (Sweden)

    Burhan Ozdil

    2010-02-01

    Full Text Available A 34-year-old woman was admitted to our clinic with abdominal pain, jaundice and pruritus. Endoscopic retrograde cholangiopancreatography was performed for cholestasis. Endoscopic retrograde cholangiopancreatography (ERCP was judged as normal, after a standard ERCP cannula was used for the cholangiogram. However, marked canalicular irregularities were identified in cholangiography when pressurized contrast agent was administrated via balloon catheter. This cholangiographic view was thought to reveal an early-stage alteration of sclerosing cholangitis. Primary sclerosing cholangitis (PSC is a chronic cholestatic liver disease characterized by destruction and fibrosis of the bile ducts. The diagnosis of PSC is based on typical cholangiographic findings, supported by nonspecific clinical signs and symptoms, cholestatic liver biochemical tests, and liver biopsy. Cholangiography is considered to be the gold standard for the diagnosis of PSC. The diagnosis is easy when diffuse multifocal biliary strictures, the hallmarks of the disease, resulting in a ‘beaded’ appearance on ERCP is detected. However, it may reveal a normal image in an early stage of the disease when bile duct changings are not prominent. We think that balloon catheter ERCP appears to facilitate the diagnosis of early-stage primary sclerosing cholangitis.

  15. Biliary transpapillary endoscopic balloon dilation for treating choledocholithiasis.

    Science.gov (United States)

    Daniel, Lubia B; Favaro, Gabriel M; Filho, Tiago F V; Cunha, Marco A B; AparÍcio, Dayse S P; Uemura, Ricardo S; Furuya, Carlos K; Artifon, Everson L A

    2015-01-01

    To evaluate the efficacy and safety of transpapillary papilloplasty in patients with choledocholithiasis. All endoscopic retrograde cholangiopancreatography (ERCP) procedures performed at Hospital Ana Costa, in the city of Santos, Brazil, over the last five years were retrospectively evaluated using the hospital's information database. The success of the procedure and complications due to residual calculi, pancreatitis, bleeding and perforation were evaluated. From January 2010 to May 2014, 1860 ERCP procedures were performed. Fifty-five patients were evaluated here. Their ages ranged from 12 to 98 years (mean, 66.3; standard deviation, 19.34; median, 71). Thirty-two patients (58.2%) were women. Sixteen (29.1%) presented giant choledocholithiasis, with calculi larger than 12 mm. Twenty-seven (49.1%) had mul-tiple choledocholithiasis. In view of the therapeutic efficacy and low complication rate among our patients, we can conclude that endoscopic papilloplasty is a safe and effective method for endoscopic treatment of choledocolithiasis in selected cases.

  16. Is endoscopic papillary large balloon dilation safe for treating large CBD stones?

    Science.gov (United States)

    Shim, Chan Sup; Kim, Ji Wan; Lee, Tae Yoon; Cheon, Young Koog

    2016-01-01

    In recent years, endoscopic papillary large balloon dilation (EPLBD) with endoscopic sphincterotomy (EST) has been shown to be an effective technique for the removal of large or difficult common bile duct (CBD) stones, as an alternative to EST. Reviewing the literature published since 2003, it is understood that EPLBD has fewer associated overall complications than EST. Bleeding occurred less frequently with EPLBD than with EST. There was no significant difference in postendoscopic retrograde cholangiopancreatography pancreatitis or perforation. Recent accumulated results of EPLBD with or even without EST suggest that it is a safe and effective procedure for the removal of large or difficult bile duct stones without any additional risk of severe adverse events, when performed under appropriate guidelines. Since use of a larger balloon can tear the sphincter as well as the bile duct, possibly resulting in bleeding and perforation, a balloon size that is equal to or smaller in diameter than the diameter of the native distal bile duct is recommended. The maximum transverse diameter of the stone and the balloon-stone diameter ratio have a tendency to affect the success or failure of complete removal of stones by large balloon dilation to prevent adverse effects such as perforation and bleeding. One should take into account the size of the native bile duct, the size and burden of stones, the presence of stricture of distal bile duct, and the presence of the papilla in or adjacent to a diverticulum. Even though the results of EPLBD indicate that it is a relatively safe procedure in patients with common duct stones with a dilated CBD, the recommended guidelines should be followed strictly for the prevention of major adverse events such as bleeding and perforation.

  17. Effects Comparison between Endoscopic Papillary Large Balloon Dilatation and Endoscopic Sphincterotomy for Common Bile Duct Stone Removal

    Directory of Open Access Journals (Sweden)

    Yandong Guo

    2015-01-01

    Full Text Available Endoscopic sphincterotomy (EST is a treatment of choice for stone extraction and is now most frequently used. The study was to compare the efficacy of endoscopic papillary large balloon dilatation (EPLBD and endoscopic sphincterotomy (EST for common bile duct stone removal. Trials comparing the effects between EPLBD and EST treatment were searched according to the study protocol. Overall stone removal rate, complete removal rate in 1st session, treatment duration, mechanical lithotripsy using rate, and overall complication rate were compared using risk ratio (RR and mean difference (MD and their 95% confidence interval (CI via RevMan 5.2 software. For overall stone removal rate, two therapies showed similar effect, but EPLBD showed better overall stone removal rate for stone >10 mm in diameter. For complete stone removal rate in 1st session, no difference was found, even for those with stone >10 mm in diameter; EPLBD showed longer treatment duration, higher mechanical lithotripsy using rate obvious overall complications rate, and more serious bleeding, whereas there were no significant differences for perforation, hyperamylasemia, pancreatitis, and cholecystitis/cholangitis. EPLBD showed better efficacy in certain conditions compared to EST, however with shortcomings, such as more duration, higher mechanical lithotripsy using rate, more serious overall complications rate, and bleeding.

  18. Successful Treatment of Early-Stage Jejunum Adenocarcinoma by Endoscopic Mucosal Resection Using Double-Balloon Endoscopy: A Case Report

    Directory of Open Access Journals (Sweden)

    Hirobumi Suzuki

    2012-01-01

    Full Text Available Small bowel adenocarcinoma (SBA has generally been considered to have a poor prognosis because of nonspecific presentations and difficulties in detection of the disease. The advent of capsule endoscopy (CE and double-balloon endoscopy (DBE makes it possible to access to the small intestine for endoscopic interventions. We describe a successful case of early jejunum adenocarcinoma completely resected by endoscopic mucosal resection (EMR using double-balloon endoscopy (DBE. Early diagnosis and EMR using new technologies such as CE and DBE may improve the recognition of this disease that, at present, has a poor prognosis.

  19. Endoscopic Papillary Large Balloon Dilation Versus Endoscopic Sphincterotomy for Retrieval of Large Choledocholithiasis: A Prospective Randomized Trial.

    Science.gov (United States)

    Omar, Mohammed A; Abdelshafy, Mohamed; Ahmed, Mohamed Yousef; Rezk, Asmaa Gaber; Taha, Abdallah M; Hussein, Hamdy M

    2017-07-01

    Endoscopic sphincterotomy (ES) is the standard technique for common bile duct (CBD) stone removal. Recently, endoscopic papillary large balloon dilation (EPLBD) has been shown to be a safe and effective technique for the removal of large CBD stone. The aim of this study was to determine the therapeutic outcomes and safety of EPLBD compared with ES for large CBD stone extraction. One hundred twenty-four patients with large bile duct stones were randomized into two groups, the first group included 61 patients subjected to EPLBD and the second group included 63 patients who underwent ES. We compared the success rate of stone removal, frequency of mechanical lithotripsy requirement, morbidity, and mortality. Baseline characteristics were not significantly different. The overall ductal clearance rate was ultimately similar between the EPLBD group (96.7%) and the ES group (93.7%) (P = .53), the one session ductal clearance rate was significantly different (86.9% versus 71.4%; P = .01). Requirement of mechanical lithotripsy was significantly different between the EPLBD and ES group (9.8% versus 17.5%, P = .04). There were no differences in complication rates between the EPLBD and ES group; pancreatitis, 4.9% versus 6.3%; minor hemorrhage, 1.6% versus 6.3%; acute cholangitis, 3.3% versus 1.9%; and recurrent stones, 3.3% versus 3.2%. The therapeutic outcomes of EPLBD for removal of large bile duct stones are better than those of ES with comparable complication rate. EPLBD is also recommended for removal of large CBD stone in patients with an underlying coagulopathy or need for anticoagulation following endoscopic retrograde cholangiopancreaticography.

  20. Comparison of endoscopic papillary balloon dilation and sphincterotomy in young patients with CBD stones and gallstones.

    Science.gov (United States)

    Seo, Yu Ri; Moon, Jong Ho; Choi, Hyun Jong; Kim, Dong Choon; Ha, Ji Su; Lee, Tae Hoon; Cha, Sang-Woo; Cho, Young Deok; Park, Sang-Heum; Kim, Sun-Joo

    2014-05-01

    Endoscopic biliary sphincterotomy (EBS) results in permanent loss of sphincter function and its long-term complications are unknown. Endoscopic papillary balloon dilation (EPBD) is an alternative procedure that preserves sphincter function, although it is associated with a higher risk of pancreatitis than is EBS. The aim of this study was to evaluate the safety and outcomes of EPBD with limited indications for removal of common bile duct (CBD) stones combined with gallstones in patients younger than 40 years. Young (age CBD stones combined with gallstones on imaging studies were enrolled in this study. A total of 132 patients were randomly divided into the EPBD group (n = 62) or the EBS group (n = 70) for extraction of CBD stones. The ballooning size of EPBD ranged from 6 to 10 mm. Complete bile duct clearance was achieved in 98.4 % (61/62) of the EPBD group and 100 % (70/70) of the EBS group. Mechanical lithotripsy was required in 8.1 % (5/62) of the EPBD group and 8.6 % (6/70) of the EBS group. The early complication rates were 8.1 % (5/62) (five pancreatitis) in the EPBD group and 11.4 % (8/70) (five [7.1 %] pancreatitis, two bleeding and one perforation) in the EBS group. The recurrence rates of CBD stones were 1.6 % (1/62) in the EPBD group and 5.7 % (4/70) in the EBS group. EPBD with limited indications was safe and effective as EBS for removal of CBD stones combined with gallstones in young patients who had a longer life expectancy.

  1. The role of endoscopic therapy in obesity management: intragastric balloons and aspiration therapy.

    Science.gov (United States)

    Kumar, Nitin; Sullivan, Shelby; Thompson, Christopher C

    2017-01-01

    Weight management is increasingly incorporating endoscopic bariatric therapy (EBT). As the global burden of obesity and its comorbidities has increased, it is evident that novel therapeutic approaches will be necessary to address the obesity epidemic. EBTs offer greater efficacy than diet and lifestyle modification and lower invasiveness than bariatric surgery. The US Food and Drug Administration has approved two intragastric balloons and aspiration therapy for the treatment of obesity: Apollo Orbera is indicated for the treatment of Class I and Class II obesity, Re Shape Integrated Dual Balloon system is indicated for the same range with a comorbidity, and Aspire Bariatrics AspireAssist is approved for patients with a body mass index of 35-55 kg/m 2 . These devices have proven safe and effective in clinical trials and are gaining commercial acceptance in the USA; the Orbera has been used extensively outside the USA for over 20 years. These devices will need to be delivered in the context of a multidisciplinary weight loss program, integrating comprehensive care of obesity. Patient selection is important, and ensuring appropriate patient expectations and understanding of alternatives such as pharmacologic therapy and surgery is essential. With several EBTs on the horizon, patients with obesity will have an even broader array of safe and effective options for weight management in the future.

  2. The Efficacy of Endoscopic Papillary Balloon Dilation for Patients with Acute Biliary Pancreatitis

    Directory of Open Access Journals (Sweden)

    Wei-Chih Sun

    2015-01-01

    Full Text Available Background. No study investigated the efficacy and safety of endoscopic papillary balloon dilation (EPBD for the treatment of acute biliary pancreatitis (ABP. Method. We retrospectively reviewed the effects of EPBD on patients with ABP from February 2003 to December 2012. The general data, findings of image studies, details of the procedure, and outcomes after EPBD were analyzed. Result. Total 183 patients (male/female: 110/73 were enrolled. The mean age was 65.9 years. Among them, 155 patients had mild pancreatitis. The meantime from admission to EPBD was 3.3 days. Cholangiogram revealed filling defects inside the common bile duct (CBD in 149 patients. The mean dilating balloon size was 10.5 mm and mean duration of the dilating procedure was 4.3 minutes. Overall, 124 patients had gross stones retrieved from CBD. Four (2.2% adverse events and 2 (1.1% intraprocedure bleeding incidents but no procedure-related mortality were noted. Bilirubin and amylase levels significantly decreased after EPBD. On average, patients resumed oral intake within 1.4 days. The clinical parameters and outcomes were similar in patients with different severity of pancreatitis. Conclusion. EPBD can be effective and safe for the treatment of ABP, even in patients presenting with severe disease.

  3. Endoscopic partial sphincterotomy coupled with large balloon papilla dilation – Single stage approach for management of extra-hepatic bile ducts macro-lithiasis

    Directory of Open Access Journals (Sweden)

    Gianfranco Donatelli

    2014-01-01

    We conclude that endoscopic partial sphincterotomy plus large papillary balloon dilation seems a promising, effective and safe approach to treat giant extrahepatic biliary calculi, if performed after correct patient selection and under established guidelines.

  4. Elimination of Postoperative Pyloric Stricture by Endoscopic Electrocauterization and Balloon Dilatation in an Infant With Congenital Antral Web

    Directory of Open Access Journals (Sweden)

    Hsun-Chin Chao

    2011-04-01

    Full Text Available We, herein, report a male infant who presented with recurrent pyloric stricture after two surgeries (web excision and antropyloroplasty, which were done, respectively, at 5 days of age for congenital antral web and 6 months of age for the subsequent pyloric stricture. The patient suffered from anorexia, progressed vomiting, and weight loss gradually after the first and second surgeries, and then, endoscopy revealed severe pyloric deformity and stricture. Poor inflation was noted during endoscopic balloon dilatation because of tight pylorus; a subsequent electrocauterization and balloon dilatation were done, and the patient’s clinical symptoms improved significantly 2 weeks later. A follow-up endoscopy was performed 1 month and 12 months after endoscopic therapy, showing steady regression of pyloric stricture. The patient had adequate diet intake and growth in the later 12 months.

  5. Endoscopic ultrasound with double-balloon endoscopy for the diagnosis of inverted Meckel’s diverticulum: a case report

    Directory of Open Access Journals (Sweden)

    Araki Akihiro

    2012-09-01

    Full Text Available Abstract Introduction Inverted Meckel’s diverticulum has usually been misdiagnosed in the cases based on computed tomography images presented in the literature. The final diagnosis was made intra-operatively or by pathology reports after surgery. Despite this, preoperative diagnosis could be made successfully by using endoscopic ultrasound with double-balloon endoscopy prior to surgery. Case presentation A 60-year-old Japanese woman with severe anemia complained of several episodes of black stool over the preceding 2 years. Abdominal computed tomography showed a 3.0-cm low-density tumor in the ileum, suggesting a diagnosis of intestinal lipoma. Examination of the tumor by endoscopic ultrasound with double-balloon endoscopy revealed a hypo-echoic layer corresponding to the muscularis propria, and a hyper-echoic layer corresponding to the fat tissue. These findings, which suggested that the tumor included areas outside the intestinal serosa, are not typical for a lipoma, despite the existence of a hyper-echoic layer corresponding to fatty tissue. We then considered a diagnosis of inverted Meckel’s diverticulum. Conclusion Lipoma and inverted Meckel’s diverticulum are difficult to differentially diagnose by computed tomography. Polypectomy is the preferred therapeutic approach when a lipoma is present; however, polypectomy in a patient with Meckel’s diverticulum requires full-thickness resection. Situations where polypectomy is performed without preparing for full-thickness resection can be avoided by first making a precise diagnosis using double-balloon endoscopy and endoscopic ultrasound.

  6. Does preserved sphincter of Oddi function prevent common bile duct stones recurrence in patients after endoscopic papillary balloon dilation?

    Directory of Open Access Journals (Sweden)

    Tzung-Jiun Tsai

    2018-04-01

    Full Text Available Background: Whether preserving sphincter of Oddi (SO function by endoscopic papillary balloon dilation (EPBD is beneficial for preventing recurrent common bile duct stone disease (CBDS is controversial. The aim of this study was to measure sphincter of Oddi (SO function by using SO manometry, and to evaluate the association with recurrent CBDS. Methods: Patients with suspected CBDS who underwent successful EPBD were included. These patients underwent SO manometry at two months after EPBD with bile duct clearance. They were regularly followed for recurrent CBDS. Results: From January 2000 to December 2009, 185 patients received EPBD and SO manometry was included. There were 64% male with mean age of 65 ± 15.6 years. Mean ballooning inflation size was 1.1 ± 0.19 cm and mean ballooning time was 4.5 ± 0.85 min 55.7% had a sphincter of Oddi basal pressure (SOBP of 0 mmHg, 16.2%  40 mmHg. In multivariate analysis, EPBD with balloon ≥1.2 cm was the only factor for loss of SO function. Moreover, patients with preserved SO function had higher stone recurrence rate (15% vs. 5%, p = 0.034. Conclusion: EPBD using balloon ≥1.2 cm is a major factor for loss of SO function, which seems to reduce the risk of recurrent CBD stones. Keywords: Common bile duct stone, Endoscopic papillary balloon dilation, Sphincter of Oddi manometry

  7. Endoscopic papillary large balloon dilation alone without sphincterotomy for the treatment of large common bile duct stones

    Directory of Open Access Journals (Sweden)

    Chen Wen-Chi

    2011-06-01

    Full Text Available Abstract Background Lethal pancreatitis has been reported after treatment for common bile duct stones using small endoscopic papillary balloon dilation. Methods We retrospectively evaluated the safety and efficacy of using large balloon dilation alone without the use of sphincterotomy for the treatment of large common bile duct stones in Kaohsiung Veterans General Hospital. Success rate of stone clearance, procedure-related adverse events and incidents, frequency of mechanical lithotripsy use, and recurrent stones were recorded. Results A total of 247 patients were reviewed in the current study. The mean age of the patients was 71.2 years. Most of them had comorbidities. Mean stone size was 16.4 mm. Among the patients, 132 (53.4% had an intact gallbladder and 121 (49% had a juxtapapillary diverticulum. The mean size of dilating balloon used was 13.2 mm. The mean duration of the dilating procedure was 4.7 min. There were 39 (15.8% patients required the help of mechanical lithotripsy while retrieving the stones. The final success rate of complete retrieval of stones was 92.7%. The rate of pancreatic duct enhancement was 26.7% (66/247. There were 3 (1.2% adverse events and 6 (2.4% intra-procedure bleeding incidents. All patients recovered completely after conservative and endoscopic treatment respectively, and no procedure-related mortality was noted. 172 patients had a follow-up duration of more than 6 months and among these, 25 patients had recurrent common bile duct stones. It was significantly correlated to the common bile duct size (p = 0.036 Conclusions Endoscopic papillary large balloon dilation alone is simple, safe, and effective in dealing with large common bile duct stones in relatively aged and debilitated patients.

  8. Analysis of the Risk Factors of Surgery after Endoscopic Balloon Dilation for Small Intestinal Strictures in Crohn's Disease Using Double-balloon Endoscopy.

    Science.gov (United States)

    Nishida, Yu; Hosomi, Shuhei; Yamagami, Hirokazu; Yukawa, Tomomi; Nagami, Yasuaki; Tanaka, Fumio; Kamata, Noriko; Tanigawa, Tetsuya; Shiba, Masatsugu; Watanabe, Toshio; Tominaga, Kazunari; Fujiwara, Yasuhiro; Arakawa, Tetsuo

    2017-09-01

    Objective Balloon-assisted endoscopy enables access to and treatment of strictures in the small intestine using endoscopic balloon dilation (EBD); however, the long-term outcomes of EBD have not been sufficiently evaluated. This study evaluated the long-term outcomes of EBD in Crohn's disease to identify the risk factors associated with the need for subsequent surgical intervention. Methods We retrospectively analyzed patients with Crohn's disease who had undergone EBD with double-balloon endoscopy (DBE) for small intestinal strictures at a single center between 2006 and 2015. The long-term outcomes were assessed based on the cumulative surgery-free rate following initial EBD. Results Seventy-two EBD with DBE sessions and 112 procedures were performed for 37 patients during this period. Eighteen patients (48.6%) required surgery during follow-up. Significant factors associated with the need for surgery in a multivariate analysis were multiple strictures (adjusted hazard ratio, 14.94; 95% confidence interval, 1.91-117.12; p=0.010). One patient (6.7%) required surgery among 15 who had single strictures compared to 17 (77.3%) among 22 patients with multiple strictures. Conclusion In a multivariate analysis, the presence of multiple strictures was a significant risk factor associated with the need for surgery; therefore, a single stricture might be a good indication for EBD using DBE for small intestinal strictures in Crohn's disease patients.

  9. Endoscopic papillary balloon dilatation in comparison with endoscopic sphincterotomy for the treatment of large common bile duct stone

    Directory of Open Access Journals (Sweden)

    Mahammad Minakari

    2013-01-01

    Conclusions: EPBD with 15-mm dilator balloon appears to be equally safe and effective compared with EST for removal of large CBD stones. So because of low complication and high success rate we recommend EPBD as the preferred method for removal of large (10-20 mm CBD stones.

  10. Endoscopic balloon dilatation as treatment of gastric outlet obstruction in infancy and childhood

    NARCIS (Netherlands)

    Heymans, H. S.; Bartelsman, J. W.; Herweijer, T. J.

    1988-01-01

    The application of balloon dilatation as treatment of gastric outlet obstruction is described. In two infants after inadequate pyloromyotomy and in an 11-year-old boy with surgical damage to the vagus, balloon dilatation was successful and considered a good alternative to surgery in these conditions

  11. Adjustable intragastric balloons: a 12-month pilot trial in endoscopic weight loss management

    NARCIS (Netherlands)

    Machytka, Evzen; Klvana, Pavel; Kornbluth, Asher; Peikin, Steven; Mathus-Vliegen, Lisbeth E. M.; Gostout, Christopher; Lopez-Nava, Gontrand; Shikora, Scott; Brooks, Jeffrey

    2011-01-01

    Intragastric balloons are associated with (1) early period intolerance, (2) diminished effect within 3-4 months, and (3) bowel obstruction risk mandating removal at 6 months. The introduction of an adjustable balloon could improve comfort and offer greater efficacy. A migration prevention function,

  12. Endoscopic papillary balloon dilation for a 7-year-old girl with choledocholithiasis.

    Science.gov (United States)

    Sogo, Tsuyoshi; Kondo, Takeo; Tsunoda, Tomoyuki; Murayama, Akitoshi; Komatsu, Haruki; Inui, Ayano; Fujisawa, Tomoo

    2013-04-01

    A 7-year-old girl was referred to our hospital for severe abdominal pain and elevated serum levels of amylase and aminotransferase. Radiological examinations revealed choledocholithiasis. EPBD was performed under intravenous anesthesia using midazolam and ketamine chloride. After fluoroscopic confirmation of a bile duct stone, a dilation balloon (30 mm-long, 8 mm-diameter) was passed over the guidewire and placed across the papilla. The balloon was gradually inflated until the notch created by the papillary sphincter disappeared. At 4 atm, the notch disappeared and the pressure was maintained for 15 s. Stone extraction was performed by using a retrieval balloon catheter. Abdominal pain disappeared immediately after EPBD, and she resumed oral intake 2 days after EPBD. In conclusion, EPBD may be a safe and effective technique for the treatment of choledocholithiasis in pediatric patients. EPDB should be selected as a treatment for pediatric choledocholithiasis in view of its advantages of preserving papillary function. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  13. The role of endoscopic therapy in obesity management: intragastric balloons and aspiration therapy

    OpenAIRE

    Kumar, Nitin; Sullivan, Shelby; Thompson, Christopher C

    2017-01-01

    Nitin Kumar,1 Shelby Sullivan,2 Christopher C Thompson3 1Bariatric Endoscopy Institute, Addison, IL, 2Gastroenterology Bariatric and Metabolic Program, University of Colorado School of Medicine, Denver, CO, 3Gastroenterology and Therapeutic Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA Abstract: Weight management is increasingly incorporating endoscopic bariatric therapy (EBT). As the global burden of obesity and its comorbidities has increased, it...

  14. Bilio-entero-gastrostomy: prospective assessment of a modified biliary reconstruction with facilitated future endoscopic access

    Directory of Open Access Journals (Sweden)

    Hamad Mostafa A

    2012-06-01

    Full Text Available Abstract Background Hepaticojejunostomy (HJ is the classical reconstruction for benign biliary stricture. Endoscopic management of anastomotic complications after hepaticojejunostomy is extremely difficult. In this work we assess a modified biliary reconstruction in the form of bilio-entero-gastrostomy (BEG regarding the feasibility of endoscopic access to HJ and management of its stenosis if encountered. Methods From October 2008 till February 2011 all patients presented to the authors with benign biliary stricture who needed bilio-enteric shunt were considered. For each patient bilio-entero-gastrostomy (BEG of either type I, II or III was constructed. In the fourth week postoperatively, endoscopy was performed to explore the possibility to access the biliary anastomosis and perform cholangiography. Results BEG shunt was performed for seventeen patients, one of whom, with BEG type I, died due to myocardial infarction leaving sixteen patients with a diagnosis of postcholecystectomy biliary injury (9, inflammatory stricture with or without choledocholithiasis (5 and strictured biliary shunt (2. BEG shunts were either type I (3, type II (3 or type III (10. Endoscopic follow up revealed successful access to the anastomosis in 14 patients (87.5%, while the access failed in one type I and one type II BEG (12.5%. Mean time needed to access the anastomosis was 12.6 min (2-55 min. On a scale from 1–5, mean endoscopic difficulty score was 1.7. One patient (6.25%, with BEG type I, developed anastomotic stricture after 18 months that was successfully treated endoscopically by stenting. These preliminary results showed that, in relation to the other types, type III BEG demonstrated the tendency to be surgically simpler to perform, endoscopicall faster to access, easier and with no failure. Conclusions BEG, which is a modified biliary reconstruction, facilitates endoscopic access of the biliary anastomosis, offers management option for its

  15. Utility of newly developed short-type double-balloon endoscopy for endoscopic retrograde cholangiography in postoperative patients.

    Science.gov (United States)

    Shimatani, Masaaki; Tokuhara, Mitsuo; Kato, Kota; Miyamoto, Sachi; Masuda, Masataka; Sakao, Masayuki; Fukata, Norimasa; Miyoshi, Hideaki; Ikeura, Tsukasa; Takaoka, Makoto; Okazaki, Kazuichi

    2017-07-01

    The utility of conventional short-type double-balloon endoscopy (DBE) for pancreatobiliary disease in patients with postoperative anatomy had been widely acknowledged and accepted. However, some technical difficulties yet remained. In an attempt to solve these problems, the new short-type DBE (N-short DBE) was uniquely designed for therapeutic endoscopic retrograde cholangiography (ERC) in postoperative patients. The aim of this study was to evaluate the usefulness of N-short DBE for ERC in postoperative patients. From August 2015 to April 2016, ERC using N-short DBE (DB-ERC) was performed in 100 postoperative patients (112 procedures). We retrospectively studied the success rate of reaching the blind end, the median time to reach the blind end, the diagnostic success rate, the therapeutic success rate, the median time to complete ERC-related interventions, the overall success rate, the median time to complete DB-ERC, and adverse events. The success rate of reaching the blind end was 99.1%. The median time to reach the blind end was 10 min (interquartile range [IQR], 6-19 min). The diagnostic success rate was 98.2%. The therapeutic success rate was 100%. The median time to complete ERC-related interventions was 36 min (IQR, 22-62 min). The overall DB-ERC success rate was 97.3%. The median time to complete DB-ERC was 54 min (IQR, 37-73 min). The occurrence of adverse events was 2.7%. The N-short DBE for ERC in postoperative patients is useful and safe. DB-ERC is promising therapeutic modality in such patients and should be selected as the first-line policy. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  16. Effectiveness of CO2-insufflated endoscopic submucosal dissection with the duodenal balloon occlusion method for early esophageal or gastric cancer: a randomized case control prospective study

    Directory of Open Access Journals (Sweden)

    Mori Hirohito

    2012-04-01

    Full Text Available Abstract Background Endoscopic submucosal dissection (ESD has typically been performed using air insufflation. Recently, however, insufflation of CO2 has been increasingly used to avoid complications. This prospective study was designed to compare the CO2 concentration, intestinal volume, and acid–base balance using the duodenal balloon procedure. Methods From June 2010 to February 2011, we enrolled 44 patients with esophageal or gastric cancer and randomly allocated them into two groups. We compared 22 patients undergoing CO2-insufflated ESD with a balloon placed into the duodenal bulb (duodenal balloon group and 22 patients undergoing regular CO2-insufflated ESD (regular group. Three-dimensional computed tomography was performed before and after the procedure to measure intestinal volume. CO2 concentrations were measured every 10 minutes. The visual analogue system (VAS scores for postoperative symptoms were recorded, and pH was measured immediately after the procedure. This was a prospective case control study randomized by the sealed envelope method. Results Intestinal CO2 gas volume before and after ESD was lower in the duodenal balloon group than in the regular group (P = 0.00027. The end-tidal CO2 level was significantly lower in the duodenal balloon group than in the regular group (P = 0.0001. No significant differences in blood ΔpH were found between the two groups. The VAS score for the occurrence of nausea due to abdominal distension after ESD indicated a significant difference (P = 0.031. Conclusions ESD using the duodenal balloon occlusion method is effective for reduction of post-ESD intestinal CO2 gas volume, resulting in a lower total amount of CO2 insufflation during ESD and reducing harmful influences on the human body to some extent.

  17. Single- and double-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y plus hepaticojejunostomy anastomosis and Whipple resection.

    Science.gov (United States)

    Itokawa, Fumihide; Itoi, Takao; Ishii, Kentaro; Sofuni, Atsushi; Moriyasu, Fuminori

    2014-04-01

    In patients with Roux-en-Y hepaticojejunostomy (HJ with R-Y) and Whipple resection, endoscopic retrograde cholangiopancreatography (ERCP) can be challenging. We report our experience with ERCP using balloon-assisted enteroscopy (BAE) (BAE-ERCP) in patients with HJ with R-Y, and Whipple resection. BAE-ERCP procedures were carried out in 62 patients (HJ with R-Y:Whipple resection=34:28). Overall, the rates of reaching the anastomosis were 85.3% (29/34) in HJ with R-Y and 96.4% (27/28) in Whipple resection. In terms of HJ with R-Y, insertion success rate by standard single-balloon enteroscopy (SBE) was 89.3% (25/28). Insertion success rate by short BAE, including SBE and double-balloon enteroscopy (DBE), was 50% (3/6). There was a statistically significant difference of insertion success rate between standard long BE and short BE (P=0.021). However, in the Whipple patients, insertion success rate by standard and short SBE was 93.8% (15/16) and 91.7% (11/12), respectively. Initial insertion success rate by short BAE in Whipple patients was significantly higher than in HJ with R-Y (91.7% vs 50%, P=0.045). Therapeutic interventions included dilation of anastomosis stricture, stone extraction, endoscopic mechanical lithotripsy, biliary stent placement, stent extraction, endoscopic nasobiliary drainage, direct cholangioscopy, and electrohydraulic lithotripsy. Our HJ with R-Y series and Whipple series treatment success rate was 90% (18/20) and 95.0% (19/20), respectively. BAE-ERCP enabled ERCP to be carried out in patients with HJ. It is considered safe and feasible. Further experience and device improvement are needed. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  18. Large Balloon Dilatation Versus Mechanical Lithotripsy After Endoscopic Sphincterotomy in the Management of Large Common Bile Duct Stones in Cirrhotic Patients: A Randomized Study.

    Science.gov (United States)

    Radwan, Mohamed I; Emara, Mohamed H; Ibrahim, Ibrahim M; Moursy, Mahmoud E

    2018-03-07

    Removal of large common bile duct (CBD) stones is one of the challenges faced during endoscopic retrograde cholangiopancreatography, and it seems more difficult in cirrhotic patients because of suspected higher rates of adverse events, especially bleeding diathesis. This study aimed at comparing the success rate and complications between mechanical lithotripsy (ML) and large balloon dilation (LBD) after endoscopic sphincterotomy in patients with liver cirrhosis. Ninety-eight cirrhotic patients with calcular obstructive jaundice were included and randomly divided into 2 groups: group A comprising 49 patients treated by LBD and group B comprising 49 patients treated by ML. All patients underwent sphincterotomy initially. All patients were subjected to thorough history taking and complete clinical examination. Pancreatic enzyme concentrations were measured 4 hours before and 24 hours after the procedure, and complete blood cell count and liver function tests were performed before and the morning after the procedure. Before and during endoscopic retrograde cholangiopancreatography, stone size and number were verified. The success rate for CBD clearance was 98% and 93.8% for LBD and ML, respectively. The rate of adverse events in this study was 10.2% (10/98), and bleeding was the commonest reported complication (5/10). Group B developed more (16.3%) adverse events than group A (4.1%), and the difference was statistically significant (P=0.04). Endoscopic sphincterotomy followed by LBD is a safe and effective treatment for large CBD stones in cirrhotic patients in comparison with sphincterotomy followed by ML.

  19. Microcatheter balloon pinning technique to facilitate wiring of a left circumflex chronic total occlusion.

    Science.gov (United States)

    Oguayo, Kevin N; Oguayo, Chris C; Vallabhan, Ravi; Choi, James W

    2017-12-01

    Coronary chronic total occlusions (CTOs) are commonly encountered during diagnostic angiograms. With recent advances, especially in experienced centers, success rates with CTO percutaneous coronary intervention (PCI) have approached 80% or higher. It is important to note that despite these advancements in techniques, CTOs remain difficult to treat. We present a case of a left circumflex artery (LCX) CTO that was successfully revascularized using a microcatheter balloon pinning technique that allowed additional wire support. A 77-year-old woman status post-two-vessel coronary artery bypass graft surgery presented with new onset angina at rest and was found to have a patent graft to the left anterior descending artery, and an unrevascularized proximal LCX CTO. PCI was attempted with a microcatheter using an antegrade approach. This approach was unsuccessful due to the lack of support and the left circumflex angle. As a result, we used a balloon to pin the microcatheter to the wall of the left main to allow for successful wiring of the LCX. A stent was successfully deployed in the LCX, and the patient was discharged from the hospital 2 days later. At follow-up, the patient was asymptomatic and returned to her usual activity. After conducting a thorough literature search, it appears that this is the first case that a microcatheter has been pinned with a balloon. We believe that in LCX CTOs that require support, the microcatheter pinning technique can provide adequate support in wiring CTO's. LCX CTOs can be very difficult to treat, we present a case of a LCX CTO that required the use of the microcatheter balloon pinning technique to allow additional wire support for successful wiring and ultimately treatment. © 2017 John Wiley & Sons Ltd.

  20. Laparoscopic Heller's cardiomyotomy achieved lesser recurrent dysphagia with better quality of life when compared with endoscopic balloon dilatation for treatment of achalasia.

    Science.gov (United States)

    Chan, S M; Chiu, P W Y; Wu, J C Y; Kwan, S M; Kwong, P Y; Lam, K W; Lo, K K; Tee, M K M; Wong, C P; Teoh, A Y B; Wong, S K H; Ng, E K W

    2013-04-01

    Achalasia is a rare primary motility disorder of esophagus; treatments include endoscopic balloon dilatation (EBD) and laparoscopic Heller's cardiomyotomy (LC). This study compared EBD versus LC for treatment of achalasia with focus on quality of life (QoL) and prevalence of post-treatment gastroesophageal reflux disease. This was a retrospective cohort study of all patients diagnosed with achalasia older than 16 treated with either EBD or LC from January 1998 to April 2008. Patients' demographic data, comorbidities, postintervention GERD symptoms, QoL, recurrence of dysphagia, reintervention rate, hospital stay, and time to resumption of diet were collected. Sixty-eight patients were recruited into the study (EBD n= 50; LC n= 18). A significant improvement in QoL was found in patients undergoing LC (0.917 vs. 0.807, P= 0.006). A higher proportion of patients treated with EBD developed post-treatment gastroesophageal reflux symptoms (60.5% vs. 43.8%) when compared with LC, although statistically insignificant (P= 0.34). Patients treated with balloon dilatation had a greater percentage of recurrence of dysphagia (55.1% vs. 26.7%; P= 0.235) and need of reintervention (42.1% vs. 9.1%; P= 0.045). However, these patients had a shorter median hospital stay (1d [range 0-4]) and earlier resumption of diet (0d [range 0-3]). Although EBD is associated with a quicker perioperative recovery, LC accomplished a better QoL, lower incidence of recurrence of dysphagia, and need of reintervention after treatment for achalasia. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  1. Successful retrieval of retained video capsule endoscope using double balloon enteroscope: A case report and review of literature

    Directory of Open Access Journals (Sweden)

    Sudhir Jagdishprasad Gupta

    2017-01-01

    Full Text Available Video capsule endoscopy is now the first-line tool in evaluating and diagnosing obscure gastrointestinal bleeding, inflammatory bowel disease, and small bowel neoplasms. Capsule retention is an uncommon but clinically significant complication. How to best retrieve these retained capsules is currently being debated. In this case report, we describe a retained capsule successfully retrieved using double-balloon enteroscopy. This case also highlights the fact that capsule retention can occur even in the absence of signs and symptoms suggestive of intestinal obstruction.

  2. Design and application of a new series of gallbladder endoscopes that facilitate gallstone removal without gallbladder excision

    Science.gov (United States)

    Qiao, Tie; Huang, Wan-Chao; Luo, Xiao-Bing; Zhang, Yang-De

    2012-01-01

    In recent years, some Chinese doctors have proposed a new concept, gallstone removal without gallbladder excision, along with transition of the medical model. As there is no specialized endoscope for gallstone removal without gallbladder excision, we designed and produced a new series of gallbladder endoscopes and accessories that have already been given a Chinese invention patent (No. ZL200810199041.2). The design of these gallbladder endoscopes was based on the anatomy and physiology of the gallbladder, characteristics of gallbladder disease, ergonomics, and industrial design. This series of gallbladder endoscopes underwent clinical trials in two hospitals appointed by the State Administration of Traditional Chinese Medicine. The clinical trials showed that surgeries of gallstones, gallbladder polyps, and cystic duct calculus could be smoothly performed with these products. In summary, this series of gallbladder endoscopes is safe, reliable, and effective for gallstone removal without gallbladder excision. This note comprehensively introduces the research and design of this series of gallbladder endoscopes.

  3. Efficacy and safety of endoscopic papillary balloon dilation for the removal of bile duct stones: Data from a “real-life” multicenter study on Dilation-Assisted Stone Extraction

    Science.gov (United States)

    Di Mitri, Roberto; Mocciaro, Filippo; Pallio, Socrate; Pecoraro, Giulia Maria; Tortora, Andrea; Zulli, Claudio; Attardo, Simona; Maurano, Attilio

    2016-01-01

    AIM To report data on Dilation-Assisted Stone Extraction (DASE) use in clinical practice and its efficacy and safety trough three Italian referral centers for biliopancreatic diseases treatment. METHODS From January 2011 to December 2015 we collected data on 120 patients treated with DASE. Technical success was obtained when the endoscopist was able to place the balloon trough the papilla inflating the balloon until the final diameter for an adequate time (at least 30 s). Clinical success was obtained after complete stone removal (no remaining stones were visible at the cholangiogram). RESULTS Forty-nine male (40.8%) and 71 female (59%) were enrolled. The mean age was 67.8 years ± 15.7. The mean common bile duct (CBD) dilation was 19.2 mm ± 3.9 and the mean size of stones 15.8 ± 2.9. DASE was applied as first approach in 38% (62% after initial failure of stones extraction). Technical and clinical success was of 91% and 87% respectively. In those in which DASE failed alternative treatment were adopted. After DASE 18% of patients experienced a complication (bleeding 9%, pancreatitis 8%, perforation 0.8%). At univariable analysis, elective endoscopic retrograde cholangiopancreatography (P = 0.031), DASE as first approach (P = 0.032), and cannulation of major papilla followed by guidewire insertion (P = 0.004) were related to low risk of complications. Pre-cut was related to an increased risk of complications (P = 0.01). CONCLUSION DASE allowed a higher first-session success rate and can be consider a valid alternative to endoscopic sphincterotomy not only for bigger CBD stones. PMID:27803771

  4. New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery.

    Science.gov (United States)

    Yozu, Ryohei; Okamoto, Kazuma; Kudo, Mikihiko; Nonaka, Hidenori; Adams, David H

    2012-04-01

    and suture technique was used in 56 cases. Newly innovated mini-mitral valve surgical instruments and techniques facilitate both direct-vision and endoscopic-assisted approaches and accomplish a favorable surgical outcome even in the complex pathology of mitral valve insufficiency. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  5. Facilitering

    DEFF Research Database (Denmark)

    Ravn, Ib

    2012-01-01

    Facilitering (af latin facilis: gørbart, let at gøre) er den teknik at gøre det lettere for en forsamlet gruppe mennesker at udrette det, den ønsker. Facilitator er en slags mødeleder eller ordstyrer, der bistår gruppen ved at styre formen på deltagernes samtale og interaktion snarere end indholdet...

  6. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  7. Endoscopic approaches to treatment of achalasia

    OpenAIRE

    Stavropoulos, Stavros N.; Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.

    2013-01-01

    Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infir...

  8. ERCP with the Balloon-Assisted Enteroscopy Technique : A Systematic Review

    NARCIS (Netherlands)

    Koornstra, Jan J.; Fry, Lucia; Moenkemueller, Klaus

    2008-01-01

    Background: Endoscopic retrograde cholangiopancreatography (ERCP) is generally difficult with conventional instruments in patients with surgically altered gastrointestinal anatomy. Balloon-assisted enteroscopy is a relatively new technique that allows for access to the papilla of Vater or a

  9. Endoscopic approaches to treatment of achalasia

    Science.gov (United States)

    Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.

    2013-01-01

    Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infirm older people, and PD may approach treatment results attained with myotomy. However, PD may need to be repeated. Small balloon dilation and endoscopic stent placement for achalasia have only been used in select centers. Per oral endoscopic myotomy is a newer endoscopic modality that will likely change the treatment paradigm for achalasia. It arose from the field of natural orifice transluminal endoscopic surgery and represents a scarless endoscopic approach to Heller myotomy. This is a technique that requires extensive training and preparation and thus there should be rigorous accreditation and monitoring of outcomes to ensure safety and efficacy. PMID:23503707

  10. Endoscopic retrograde cholangiopancreatography and endoscopic ...

    African Journals Online (AJOL)

    An approach to suspected gallstone pancreatitis'based on endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (ES) was adopted in 1976 and was followed in 29 patients. ERCp became the routine method of early biliary tract assessment when gallstone pancreatitis was suspected on ...

  11. Endoscopic Treatment of Gastric Outlet Obstruction Secondary to Accidental Acid Ingestion in a Child.

    Science.gov (United States)

    Andrade, Mateus; Sawamura, Regina; Cupo, Palmira; Del Ciampo, Ieda R Lopes; Fernandes, Maria I M

    2016-01-01

    Accidental corrosive ingestion is not rare in pediatric patients in developing countries. We report a case of gastric outlet obstruction after the accidental ingestion of an acidic substance by a child who was successfully treated with endoscopic balloon dilatation.

  12. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  13. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  14. Balloon Command-Control

    Science.gov (United States)

    1977-01-07

    Continuo on reverse side Ii nocosom7’ and identify by block numnber) P cientific Balloons; Balloon flights; Telemetry; Balloon Control; plight Termination... improvements in the ground station which should result in a truly simplified operation. The final modification to the decoder board which appears... improve the sweep range nnd sweep rate, however, the wave shape is still not as good as achieved using an exter..al sine wave oscillator manually

  15. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  16. The Japanese Balloon Program

    Science.gov (United States)

    Nishimura, J.

    The Japanese scientific ballooning program has been organized by ISAS since the institute was founded in mid 1960s. Since then, the balloon group of ISAS has been engaged in the development of the balloon technologies and scientific observations in collaboration with scientists and engineers in other universities and organizations. Here, I describe several subjects of recent activities, the details of some items will also be reported in the separate papers in this meeting.Preparation of a new mobile receiving station.Balloons of made of the EVAL (Ethylene-Vinyl-Alcohol) films. EVAL film has specific Infra-red absorption bands, and is expected to be useful for saving the ballast for a long duration flight.A high altitude balloon with thin polyethylene films achieving at an altitude of above 50km. Further improvement of this type of balloons is continued by inventing how to extrude thin films less than 5 microns of thickness.Recent achievement of Antarctica Flights under the collaboration of ISAS and National Polar Institute.Other new efforts to long duration flights such as satellite link boomerang balloon systems and others.New balloon borne scientific instrumentation for observations of high energy electrons and Anti-protons in cosmic-rays.

  17. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  18. Modified Hydrogen Balloon Explosion.

    Science.gov (United States)

    Lawrence, Stephen S.

    1995-01-01

    Describes the technique of exploding an oxygen-hydrogen balloon using two balloons and having students observe the formation of water droplets. Suggests that the Socratic Method can be used to start discussions related to stochiometry, states of matter, and gas laws. (DDR)

  19. Endoscopic dacryocystorhinostomy

    Directory of Open Access Journals (Sweden)

    Milojević Milanko

    2010-01-01

    Full Text Available Background/Aim. Intensive epiphora (lacrimal apparatus disease can make difficult daily routine and cause ocular refraction disturbances. In most cases ethiology is unknown, rarely occurs after nose surgical procedures, face fractures, in Wegener granulomatosis, sarcoidosis and malignancies. The aim of this study was to evaluate efficacy of endonasal endoscopic surgical procedure with the conventional surgical instruments in treatment of nasolacrimal obstructions. Methods. This retrospective study included 12 female patients with endonasal endoscopic surgical procedure from Otorhinological and Ophtalmological Departments of Military Medical Academy, Belgrade from September 2007 to April 2009. Preoperative nasal endoscopy was performed in order to reveal concomitant pathological conditions and anatomic anomalies which could make surgical procedure impossible. Computerized tomography was performed only in suspect nose diseases. Surgical endonasal endoscopic procedure was performed by otorhinolaryngologist and ophtalmologist in all patients. The patients had regular controls from 2 to 20 months. Results. A total of 12 female patients, age 34-83 years, were included in our study. Epiphora was a dominant symptom in all patients. In two patients deviation of nasal septum was found, and in other one conha bulosa at the same side as chronic dacryocystitis. All patients were subjected to endonasal dacryocystorhinostomy (DCR by endoscopic surgical technique using conventional instruments. Concomitantly with DCR septoplastics in two patients and lateral lamictetomy in one patient were performed. There were no complications intraoperatively as well as in the immediate postoperative course. In two patients the need for reoperation occurred. Conclusion. Endoscopic DCR is minimally invasive and efficacious procedure for nasolacrymal obstructions performed by otorhinolaryngologist and ophtalmologist. Postoperative recovery is very fast.

  20. Ureteric angioplasty balloon placement to increase localised dosage of BCG for renal pelvis TCC.

    LENUS (Irish Health Repository)

    Forde, J C

    2012-03-01

    Endoscopic percutaneous resection of a renal pelvis transitional cell carcinoma (TCC) is a viable treatment option in those who would be rendered dialysis dependent following a nephroureterectomy. We report endoscopic percutaneous resection of an upper tract TCC recurrence in a single functioning kidney followed by antegrade renal pelvis BCG instillation with novel placement of inflated angioplasty balloon in the ureter to help localise its effect.

  1. Endoscopic tattooing.

    Science.gov (United States)

    Kethu, Sripathi R; Banerjee, Subhas; Desilets, David; Diehl, David L; Farraye, Francis A; Kaul, Vivek; Kwon, Richard S; Mamula, Petar; Pedrosa, Marcos C; Rodriguez, Sarah A; Wong Kee Song, Louis-Michel; Tierney, William M

    2010-10-01

    The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through January 2010 for articles related to endoscopic tattooing by using the Keywords tattooing, colonic, endoscopic, India ink, indocyanine green in different search term combinations. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by

  2. Safety and effectiveness of gastric balloons associated with hypocaloric diet for the treatment of obesity

    Directory of Open Access Journals (Sweden)

    M.ª Luisa de Castro

    2013-10-01

    Full Text Available Introduction: intragastric balloons provide early satiety and thereby induce short-term weight loss. The aim of this study was to evaluate safety and short and medium-term effectiveness of gastric balloons associated to hypocaloric diet in obesity. Material and methods: from May 2004 to June 2011 91 obese patients, body mass index [BMI] 45.2 ± 7.2 kg/m² were prospectively followed after endoscopic implantation of a gastric balloon associated to restricted diet. Successful therapy was defined as percent loss of total weight (%LTW ≥ 5% at six months after balloon placement and 6 and 12 months after their withdrawal. All analyses followed intention-to treat principles considering significant p-values < 0.05. Results: we placed 73 fluid-filled balloons (80.2% and 18 air-filled ones (19.8%. Compared to baseline values, at 6-month 73.7% subjects succeeded, showing significant reductions in weight (13.3 ± 8.8 kg, BMI (5 ± 3.4 kg/m² (p < 0.0001, with% LTW 11 ± 7%. Six and twelve months after retrieval 45.1% and 28.6% patients reached% LTW ≥ 5%. Short-term and medium-term effectiveness was negatively associated to obesity in first-grade relatives (p = 0.003 and p = 0.04. Higher weight loss 6 months after balloon placement independently predicted medium-term effectiveness (p = 0.0001. Mortality was absent but there were two spontaneous deflations of air-filled balloons and severe withdrawal difficulties in 8 patients, leading to surgery in one case. Retrieval complications associated to air-filled balloons (p = 0.0005. Conclusions: in obesity, effectiveness of gastric balloons associated to hypocaloric diet decreases over time. Complications occurred mainly in the retrieval endoscopic procedure and related to air-filled balloons.

  3. Endoscopic Microscopy

    Directory of Open Access Journals (Sweden)

    Konstantin Sokolov

    2002-01-01

    Full Text Available In vivo endoscopic optical microscopy provides a tool to assess tissue architecture and morphology with contrast and resolution similar to that provided by standard histopathology – without need for physical tissue removal. In this article, we focus on optical imaging technologies that have the potential to dramatically improve the detection, prevention, and therapy of epithelial cancers. Epithelial pre-cancers and cancers are associated with a variety of morphologic, architectural, and molecular changes, which currently can be assessed only through invasive, painful biopsy. Optical imaging is ideally suited to detecting cancer-related alterations because it can detect biochemical and morphologic alterations with sub-cellular resolution throughout the entire epithelial thickness. Optical techniques can be implemented non-invasively, in real time, and at low cost to survey the tissue surface at risk. Our manuscript focuses primarily on modalities that currently are the most developed: reflectance confocal microscopy (RCM and optical coherence tomography (OCT. However, recent advances in fluorescence-based endoscopic microscopy also are reviewed briefly. We discuss the basic principles of these emerging technologies and their current and potential applications in early cancer detection. We also present research activities focused on development of exogenous contrast agents that can enhance the morphological features important for cancer detection and that have the potential to allow vital molecular imaging of cancer-related biomarkers. In conclusion, we discuss future improvements to the technology needed to develop robust clinical devices.

  4. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  5. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  6. Endoscopic Dilatation versus Oesophageal Stent in Benign Oesophageal Stricture

    Directory of Open Access Journals (Sweden)

    Hadyanto Caputra

    2016-09-01

    Full Text Available Aim: Oesophageal stricture is one of the causes of dysphagia. It is a condition in which the lumen of oesophagus is narrowed by fibrotic tissue in the oesophageal wall. It is usually caused by inflammation or any other cause that leads to necrotizing of tissue. It is mainly differentiated into benign or malignant. The aim of this article is to answer the clinical question on the effectiveness of oesophageal stenting compared to endoscopic dilatation in patient with benign oesophageal stricture due to ingestion of corrosive substances, who had undergone several endoscopic dilatations. Method: We conducted search of relevant articles using PubMed search engine to answer the clinical question. Keywords being used during the search process were: ("oesophageal stricture"[All Fields] OR "oesophageal stenosis"[All Fields] AND (("dilatation"[All Fields] AND ("stents"[MeSH Terms] OR "stents"[All Fields] OR "stent"[All Fields]. Results were further converged by adding specific filters, which were full text articles and clinical trial. Results: The chosen article was further appraised in order to identify its validity and eligibility to answer the clinical question. We chose to use CONSORT (statement to improve the quality of reporting of RCTs to facilitate the critical appraisal and interpretation of RCTs. Conclusion: Stenting was associated with greater dysphagia, co-medication and adverse events. No randomized controlled trials which compared biodegradable stents with other stents or with balloon dilatation was identified. Lack of adequately robust evidence for effectiveness and cost-effectiveness formed the rationale of this trial.

  7. GI endoscopes.

    Science.gov (United States)

    Varadarajulu, Shyam; Banerjee, Subhas; Barth, Bradley A; Desilets, David J; Kaul, Vivek; Kethu, Sripathi R; Pedrosa, Marcos C; Pfau, Patrick R; Tokar, Jeffrey L; Wang, Amy; Wong Kee Song, Louis-Michel; Rodriguez, Sarah A

    2011-07-01

    The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through September 2010 for articles related to endoscopy by using the key words "gastroscope," "colonoscope," "echoendoscope," "duodenoscope," "choledochoscope," "ultraslim endoscope," "variable stiffness colonoscope," and "wide-angle colonoscope." Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment. Copyright © 2011 American Society for Gastrointestinal

  8. Therapeutic balloon-assisted enteroscopy

    NARCIS (Netherlands)

    H. Aktas (Huseyin); P.B.F. Mensink (Peter)

    2009-01-01

    textabstractSince the introduction of the first balloon-based enteroscopic technique in 2001, therapeutic balloon-assisted enteroscopy (BAE) using either the single or double balloon enteroscopy technique (respectively SBE and DBE) has evolved rapidly. Argon plasma coagulation (APC), polypectomy,

  9. Endoscopic sphincterotomy with sphincteroplasty for the management of choledocholithiasis: a single-centre experience.

    Science.gov (United States)

    Ho, Simon; Rayzan, Daniel; Fox, Adrian; Kalogeropoulos, George; Mackay, Sean; Hassen, Sayed; Banting, Simon; Cade, Richard

    2017-09-01

    Balloon dilatation of the ampulla at endoscopic retrograde cholangiopancreatography (ERCP) is increasingly utilized in the management of large bile duct stones. The aim of this study was to review and compare the outcomes of using endoscopic sphincterotomy with endoscopic balloon dilatation (sphincteroplasty) in a combined approach as a single-stage (immediate) or a two-stage procedure (delayed). A retrospective review of medical records for all patients undergoing ERCP and balloon dilatation for choledocholithiasis between January 2010 and December 2012 was undertaken. Outcomes measured included patient demographics, stone size, degree of dilatation performed, success of stone extraction, number of procedures required for duct clearance and procedure-related complications. One hundred and thirty-six ERCPs were performed with balloon sphincteroplasty. One hundred and four had a previous sphincterotomy with a delayed balloon dilatation and 32 had sphincterotomy with immediate dilatation. The overall clearance rate of the common bile duct for immediate and delayed groups was 93% (28/30) and 93% (81/87), respectively. Bile duct clearance after the first procedure was achieved in 70% (21/30) of patients in the immediate group and 74% (64/87) in the delayed group. There were six complications in the delayed group and four in the immediate group. The most frequently used balloon size was 10 mm for both groups with mean sizes of 10.34 (2.93) and 11.73 (2.87) in the immediate and delayed groups, respectively. Our study suggests that use of a combined approach is safe and effective and may provide benefits over using endoscopic balloon dilatation or endoscopic sphincterotomy alone in the treatment of choledocholithiasis. © 2015 Royal Australasian College of Surgeons.

  10. Assessing mechanical properties with intravascular or endoscopic optical coherence tomography

    Science.gov (United States)

    Lamouche, G.; Azarnoush, H.; Vergnole, S.; Pazos, V.; Bisaillon, C.-E.; Debergue, P.; Boulet, B.; Diraddo, R.

    2011-03-01

    We explore the potential of intravascular or endoscopic optical coherence tomography (OCT) to extract relevant mechanical properties of a tissue deformed by an inflating balloon. Tubular OCT phantoms with different mechanical properties are fabricated. The phantoms are deformed by an inflating balloon, and the deformation is monitored with OCT. A quantitative description of the phantom deformation is obtained by segmenting the OCT images. Two strategies to extract the mechanical properties from this quantitative data are presented: by comparing to a finite-element simulation and by performing a mechanical analysis.

  11. Adjustable continence balloons

    DEFF Research Database (Denmark)

    Kjær, Line; Fode, Mikkel; Nørgaard, Nis

    2012-01-01

    . Fourteen patients (12%) ended up with an artificial sphincter or a urethral sling. Sixty patients (63%) experienced no discomfort and 58 (61%) reported being dry or markedly improved. Overall, 50 patients (53%) reported being very or predominantly satisfied. Conclusions. Adjustable continence balloons seem...

  12. Medical Devices for Obesity Treatment: Endoscopic Bariatric Therapies.

    Science.gov (United States)

    Vargas, Eric J; Rizk, Monika; Bazerbachi, Fateh; Abu Dayyeh, Barham K

    2018-01-01

    Endoscopic bariatric therapies (EBTs) are effective tools for the management of obesity. By mimicking restrictive and bypass surgery physiology, they provide a safe and effective treatment option with the added capabilities of reaching a broader population. Multiple efficacious medical devices, such as intragastric balloons, endoscopic suturing/plication devices, and bypass liners, at various stages of development are available in the United States. EBTs represent the newest addition to a multidisciplinary approach in obesity management. This article reviews several devices' safety and efficacy for primary care providers in the era of evolving obesity treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Endoscopic dacryocystrhinostomy.

    Science.gov (United States)

    Araujo Filho, Bernardo Cunha; Voegels, Richard Louis; Butugan, Ossamu; Pinheiro Neto, Carlos Diogenes; Lessa, Marcus Miranda

    2005-01-01

    Endonasal endoscopic dacryocystorhinostomy (EN-DCR) is now a well-established procedure to relieve nasolacrimal duct obstruction, becoming its domain for the ENT surgeons indispensable. The aim of the present study is to report the experience of the Otorhinolaryngology Department of the University of São Paulo Medical School in the management of the obstruction of the drainage of the nasolacrimal system by EN-DCR, comparing with the results in literature. clinical retrospective. We reviewed the medical records of 17 patients (17 eyes) that were submitted to EN-DCR between april 2001 and july 2004. We analysed: sex, age at the time of diagnosis, etiology, clinical findings, surgical technique, use of silicone tubes, follow-up and complications. Eight men and nine women, the age range was from 29 to 79 years (mean 42.6413.1 years), mean follow-up time: 15 months, presented a lacrimal clinic with epiphora. Powered DCR was performed in 06 cases and YAG LASER in 01 patient. Silicone tubes were used in all cases and left in place mean 7.9 weeks. The surgical success rate was 82,3%. EN-DCR showed one safe technique, with advantages in relation to the external technique. So ophthalmologists and ENT physicians must work in harmony to offer more benefits to its patients.

  14. Endoscopic Approach for Major Complications of Bariatric Surgery.

    Science.gov (United States)

    Joo, Moon Kyung

    2017-01-01

    As lifestyle and diet patterns have become westernized in East Asia, the prevalence of obesity has rapidly increased. Bariatric surgeries, such as Roux-en-Y gastric bypass (RYGB), sleeve gastrectomy (SG), and laparoscopic adjustable gastric banding (LAGB), are considered the first-line treatment option in patients with severe obesity. However, postoperative complications have increased and the proper management of these complications, including the use of endoscopic procedures, has become important. The most serious complications, such as leaks and fistulas, can be treated with endoscopic stent placement and injection of fibrin glue, and a novel full-thickness closure over-the-scope clip (OTSC) has been used for treatment of postoperative leaks. Stricture at the gastrojejunal (GJ) anastomosis site after RYGB or incisura angularis in SG can be managed using stents or endoscopic balloon dilation. Dilation of the GJ anastomosis or gastric pouch may lead to failure of weight loss, and the use of endoscopic sclerotherapy, novel endoscopic suturing devices, and OTSCs have been attempted. Intragastric migration of the gastric band can be successfully treated using various endoscopic tools. Endoscopy plays a pivotal role in the management of post-bariatric complications, and close cooperation between endoscopists and bariatric surgeons may further increase the success rate of endoscopic procedures.

  15. Gastric Outlet Obstruction After Esophagectomy: Retrospective Analysis of the Effectiveness and Safety of Postoperative Endoscopic Pyloric Dilatation.

    Science.gov (United States)

    Maus, Martin K H; Leers, Jessica; Herbold, Till; Bludau, Marc; Chon, Seung-Hun; Kleinert, Robert; Hescheler, Daniel A; Bollschweiler, Elfriede; Hölscher, Arnulf H; Schäfer, Hartmut; Alakus, Hakan

    2016-10-01

    Delayed gastric emptying after esophagectomy with gastric replacement can pose a significant postoperative problem, often leading to aspiration and pneumonia. The present study analyzes retrospectively the effectiveness of endoscopic pyloric dilatation for post-surgical gastric outlet obstruction. Between March 2006 and March 2010, 403 patients underwent a transthoracic en-bloc esophagectomy and reconstruction with a gastric tube and intrathoracic esophagogastrostomy. In patients with postoperative symptoms of an outlet dysfunction and the confirmation by endoscopy, pyloric dilatations were performed without preference with either 20- or 30-mm balloons. A total of 89 balloon dilatations of the pylorus after esophagectomy were performed in 60 (15.6 %) patients. In 21 (35 %) patients, a second dilatation of the pylorus was performed. 55 (61.8 %) dilatations were performed with a 30-mm balloon and 34 (38.2 %) with a 20-mm balloon. The total redilatation rate for the 30-mm balloon was 20 % (n = 11) and 52.9 % (n = 18) for the 20-mm balloon (p gastric emptying leading to postoperative complications after esophagectomy. Endoscopic pyloric dilatation after esophagectomy is a safe procedure for treatment of gastric outlet obstruction. The use of a 30-mm balloon has the same safety profile but a 2.5 lower redilatation rate compared to the 20-mm balloon. Thus, the use of 20-mm balloons has been abandoned in our clinic.

  16. Navigated retrograde endoscopic myotomy (REM) for the treatment of therapy-resistant achalasia.

    Science.gov (United States)

    Pham, K D; Havre, R F; Langø, T; Hofstad, E F; Tangen, G A; Mårvik, R; Pham, T; Gilja, O H; Hatlebakk, J G; Viste, A

    2017-11-16

    In achalasia, muscle spasm may involve the proximal esophagus. When the muscle spasm is located in the proximal esophagus, conventional per oral endoscopic myotomy (POEM) may not be sufficient to relieve symptoms. In this paper, we describe retrograde endoscopic myotomy (REM) as a novel approach to perform myotomy of the proximal esophagus, with the application of a navigation tool for anatomical guidance during REM. We aim to evaluate the feasibility and safety of REM and usefulness of the navigation during REM. A 42-year-old male with type III achalasia who was treated with laparoscopic myotomy with fundoplication, multiple pneumatic balloon dilations, Botox injections and anterior POEM of the middle and distal esophagus without symptomatic effect. Repeated high-resolution- manometry (HRM) revealed occluding contractions of high amplitude around and above the aortic arch. A probe-based real-time electromagnetic navigation platform was used to facilitate real-time anatomical orientation and to evaluate myotomy position and length during REM. The navigation system aided in identifying the major structures of the mediastinum, and position and length of the myotomy. Twelve weeks after REM, the Eckardt score fell from seven at baseline seven to two. We also observed improvement with reduction of the pressure at the level of previous spasms in the proximal esophagus from 124 mmHg to 8 mmHg on HRM. REM makes the proximal esophagus accessible for endoscopic myotomy. Potential indication for REM is motility disorders in the proximal esophagus and therapy failure after POEM. © 2017 John Wiley & Sons Ltd.

  17. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  18. Direct peroral cholangioscopy using an ultrathin endoscope: making technique easier

    Directory of Open Access Journals (Sweden)

    Javier Sola-Vera

    2014-01-01

    Full Text Available Background: Cholangioscopy is a useful tool for the study and treatment of biliary pathology. Ultrathin upper endoscopes allow direct peroral cholangioscopy (DPC but have some drawbacks. Objective: The aim of the study was to evaluate the success rate of DPC with an ultrathin endoscope using a balloon catheter to reach the biliary confluence. Material and methods: Prospective observational study. An ultrathin endoscope (Olympus XP180N, outer diameter 5.5 mm, working channel 2 mm was used. To access the biliary tree, free-hand technique was used. To reach the biliary confluence an intraductal balloon catheter (Olympus B5-2Q diameter 1.9 mm and a 0.025 inch guide wire was used. In all cases sphincterotomy and/or sphincteroplasty was performed. The success rate was defined as the percentage of cases in which the biliary confluence could be reached with the ultrathin endoscope. Results: Fifteen patients (8 men/7 women were included. Mean age was 77.7 ± 10.8 years (range 45-91. The indications for cholangioscopy were suspected bile duct stones (n = 9, electrohydraulic lithotripsy for the treatment of difficult choledocholithiasis (n = 5 and evaluation of biliary stricture (n = 1. Access to the bile duct was achieved in 14/15 cases (93.3 %. Biliary confluence was reached in 13/15 cases (86.7 %. One complication was observed in one patient (oxigen desaturation. Conclusions: DPC with an ultrathin endoscope can be done with the free-hand technique. Intraductal balloon-guided DPC allows full examination of the common bile duct in most cases.

  19. Endoscopic third ventriculostomy

    Directory of Open Access Journals (Sweden)

    Yad Ram Yadav

    2012-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is considered as a treatment of choice for obstructive hydrocephalus. It is indicated in hydrocephalus secondary to congenital aqueductal stenosis, posterior third ventricle tumor, cerebellar infarct, Dandy-Walker malformation, vein of Galen aneurism, syringomyelia with or without Chiari malformation type I, intraventricular hematoma, post infective, normal pressure hydrocephalus, myelomeningocele, multiloculated hydrocephalus, encephalocele, posterior fossa tumor and craniosynostosis. It is also indicated in block shunt or slit ventricle syndrome. Proper Pre-operative imaging for detailed assessment of the posterior communicating arteries distance from mid line, presence or absence of Liliequist membrane or other membranes, located in the prepontine cistern is useful. Measurement of lumbar elastance and resistance can predict patency of cranial subarachnoid space and complex hydrocephalus, which decides an ultimate outcome. Water jet dissection is an effective technique of ETV in thick floor. Ultrasonic contact probe can be useful in selected patients. Intra-operative ventriculo-stomography could help in confirming the adequacy of endoscopic procedure, thereby facilitating the need for shunt. Intraoperative observations of the patent aqueduct and prepontine cistern scarring are predictors of the risk of ETV failure. Such patients may be considered for shunt surgery. Magnetic resonance ventriculography and cine phase contrast magnetic resonance imaging are effective in assessing subarachnoid space and stoma patency after ETV. Proper case selection, post-operative care including monitoring of ICP and need for external ventricular drain, repeated lumbar puncture and CSF drainage, Ommaya reservoir in selected patients could help to increase success rate and reduce complications. Most of the complications develop in an early post-operative, but fatal complications can develop late which indicate an importance of

  20. Update on endoscopic management of gastric outlet obstruction in children.

    Science.gov (United States)

    Chao, Hsun-Chin

    2016-10-16

    Endoscopic balloon dilatation (EBD) and surgical intervention are two most common and effective treatments for gastric outlet obstruction. Correction of gastric outlet obstruction without the need for surgery is an issue that has been tried to be resolved in these decades; this management has developed with EBD, advanced treatments like local steroid injection, electrocauterization, and stent have been added recently. The most common causes of pediatric gastric outlet obstruction are idiopathic hypertrophic pyloric stenosis, peptic ulcer disease followed by the ingestion of caustic substances, stenosis secondary to surgical anastomosis; antral web, duplication cyst, ectopic pancreas, and other rare conditions. A complete clinical, radiological and endoscopic evaluation of the patient is required to make the diagnosis, with complimentary histopathologic studies. EBD are used in exceptional cases, some with advantages over surgical intervention depending on each patient in particular and on the characteristics and etiology of the gastric outlet obstruction. Local steroid injection and electrocauterization can augment the effect of EBD. The future of endoscopic treatment seems to be aimed at the use of endoscopic electrocauterization and balloon dilatations.

  1. Update on endoscopic management of gastric outlet obstruction in children

    Science.gov (United States)

    Chao, Hsun-Chin

    2016-01-01

    Endoscopic balloon dilatation (EBD) and surgical intervention are two most common and effective treatments for gastric outlet obstruction. Correction of gastric outlet obstruction without the need for surgery is an issue that has been tried to be resolved in these decades; this management has developed with EBD, advanced treatments like local steroid injection, electrocauterization, and stent have been added recently. The most common causes of pediatric gastric outlet obstruction are idiopathic hypertrophic pyloric stenosis, peptic ulcer disease followed by the ingestion of caustic substances, stenosis secondary to surgical anastomosis; antral web, duplication cyst, ectopic pancreas, and other rare conditions. A complete clinical, radiological and endoscopic evaluation of the patient is required to make the diagnosis, with complimentary histopathologic studies. EBD are used in exceptional cases, some with advantages over surgical intervention depending on each patient in particular and on the characteristics and etiology of the gastric outlet obstruction. Local steroid injection and electrocauterization can augment the effect of EBD. The future of endoscopic treatment seems to be aimed at the use of endoscopic electrocauterization and balloon dilatations. PMID:27803770

  2. Biliary fascioliasis: Management in a child using endoscopic retrograde cholangio pancreatography

    Directory of Open Access Journals (Sweden)

    Sandesh V Parelkar

    2013-01-01

    Full Text Available A 9-year-old boy presented with right upper abdominal pain and fever. The radiologic investigations revealed multiple cholangitic abscesses with cholangitis and worms in common bile duct. Endoscopic retrograde cholangio pancreatographic (ERCP sphincterotomy, basketing, ballooning and extraction of Fasciola hepatica worms from the common bile duct were done.

  3. Biliary fascioliasis: Management in a child using endoscopic retrograde cholangio pancreatography

    Science.gov (United States)

    Parelkar, Sandesh V.; Oak, Sanjay N.; Maydeo, Amit; Sanghvi, Beejal V.; Joshi, Prashant B.; Chaubal, Nitin; Patil, Rajasekhara T.; Sahoo, Subrat K.; Lal, Patel Jiwan; Sampath, Nandita; Koticha, Avani

    2013-01-01

    A 9-year-old boy presented with right upper abdominal pain and fever. The radiologic investigations revealed multiple cholangitic abscesses with cholangitis and worms in common bile duct. Endoscopic retrograde cholangio pancreatographic (ERCP) sphincterotomy, basketing, ballooning and extraction of Fasciola hepatica worms from the common bile duct were done. PMID:23599579

  4. 28. Critical pulmonary valve stenosis: Medical management beyond balloon dilation

    Directory of Open Access Journals (Sweden)

    Muhammad Arif Khan

    2015-10-01

    Conclusion: Phentolamine and/or Captopril have a therapeutic role in neonates with critical PVS who remain oxygen dependent after balloon dilation. Both medicationslead to vasodilatation of pulmonary and systemic vascularity. They facilitate inflowto the right ventricle. Right to left shunt across a PFO or/ ASD minimizesand saturation improves leading to a significantreduction in length of hospitalization.

  5. VVER ballooning experiments

    International Nuclear Information System (INIS)

    Gyoeri, Cs.; Hozer, Z.; Maroti, L.; Matus, L.

    1998-01-01

    A series of ballooning experiments was performed at the KFKI-AEKI in order to compare the mechanical behaviour and strength of Zircaloy-4 and Zr1%Nb claddings. The effects of temperature, oxidation and iodine absorption on deformation and burst pressure was investigated in almost 100 biaxial tests. Numerical post-test analyses have also been performed with the stand-alone fuel module of the French CATHARE code and the US fuel behaviour code FRAP-T6. Comparing the experimental and the analytical results, relevant differences of high temperature strength due to different α-β phase transition temperature were revealed between the investigated cladding materials. (author)

  6. Aerodynamics of a Party Balloon

    Science.gov (United States)

    Cross, Rod

    2007-01-01

    It is well-known that a party balloon can be made to fly erratically across a room, but it can also be used for quantitative measurements of other aspects of aerodynamics. Since a balloon is light and has a large surface area, even relatively weak aerodynamic forces can be readily demonstrated or measured in the classroom. Accurate measurements…

  7. Treatment of urethral strictures with balloon dilation: A forgotten tale

    Directory of Open Access Journals (Sweden)

    Konstantinos Stamatiou

    2015-09-01

    Full Text Available Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization and dilation, urethroplasty and endoscopic internal urethrotomy as well. Although treatment option depends on the type, length and aetiology of stricture, the choice can be influenced to varying degrees by the simplicity of the method, the preferences of the patient the available accoutrements and the patient health condition. Both urethroplasty and endoscopic internal urethrotomy require anaesthesia and thus are not suitable for many elder and unfit for surgical treatment patients. On the other hand, dilations are easy to perform in every day clinical practice however they have been associated with iatrogenic urethral trauma. In contrast, balloon dilation under vision dilates by radial application of forces against the stricture, avoiding the potentially shearing forces associated with sequential rigid dilation. Since it reduces the possibility of an iatrogenic urethral trauma and the subsequent spongiofibrosis may lead into improved therapeutic outcomes. In this report we describe a technique for the treatment of urethral strictures with balloon dilation in elder and unfit for surgical treatment patients.

  8. [BALLOON DILATATION IN COMBINATION WITH A DOSED PAPILLOTOMY IN THE TREATMENT OF DIFFICULT FORMS OF CHOLEDOCHOLITHIASIS].

    Science.gov (United States)

    Shapovalova, E I; Grubnik, V V; Tkachenko, A I; Gerasimov, D V; Romak, R P

    2016-04-01

    Results of treatment was studied in 2008 - 2015 yrs in 57 patients, suffering "difficult stones" (choledocholithiasis), in whom a dosed papillotomy in combination with the balloon dilatation. The advantages of application of combined dosed endoscopic papillosphincterotomy and balloon dilatation, comparing with complete endoscopic papillosphincterotomy, while treating "difficult stones" of common biliary duct, were established. Application of the procedure have guaranteed a good access through the duodenal papilla magna and have permitted to perform the calculi extraction in a less traumatic way, what have promoted its function preservation, and reduction of a postoperative complications rate, the patients' stationary treatment duration, and the remote complications rate. Using questionnaire SF-36, the quality of life was analyzed in patients, in whom in remote period the duodenal papilla magna function was preserved.

  9. Air Force Cambridge Research Laboratories balloon operations

    Science.gov (United States)

    Danaher, T. J.

    1974-01-01

    The establishment and functions of the AFCRL balloon operations facility are discussed. The types of research work conducted by the facility are defined. The facilities which support the balloon programs are described. The free balloon and tethered balloon capabilities are analyzed.

  10. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  11. The University of Alberta High Altitude Balloon Program

    Science.gov (United States)

    Johnson, W.; Buttenschoen, A.; Farr, Q.; Hodgson, C.; Mann, I. R.; Mazzino, L.; Rae, J.; University of Alberta High Altitude Balloon Team

    2011-12-01

    The University of Alberta High Altitude Balloon (UA-HAB) program is a one and half year program sponsored by the Canadian Space Agency (CSA) that offers hands on experience for undergraduate and graduate students in the design, build, test and flight of an experimental payload on a high altitude balloon platform. Utilising low cost weather balloon platforms, and through utilisation of the CSA David Florida Laboratory for thermal-vacuum tests , in advance of the final flight of the payload on a NASA high altitude balloon platform. Collectively the program provided unique opportunities for students to experience mission phases which parallel those of a space satellite mission. The program has facilitated several weather balloon missions, which additionally provide educational opportunities for university students and staff, as well as outreach opportunities among junior and senior high school students. Weather balloon missions provide a cheap and quick alternative to suborbital missions; they can be used to test components for more expensive missions, as well as to host student based projects from different disciplines such as Earth and Atmospheric Sciences (EAS), Physics, and Engineering. In addition to extensive skills development, the program aims to promote recruitment of graduate and undergraduate students into careers in space science and engineering. Results from the UA-HAB program and the flight of the UA-HAB shielded Gieger counter payload for cosmic ray and space radiation studies will be presented. Lessons learned from developing and maintaining a weather balloon program will also be discussed. This project is undertaken in partnership with the High Altitude Student Platform, organized by Louisiana State University and the Louisiana Space Consortium (LaSpace), and sponsored by NASA, with the financial support of the Canadian Space Agency.

  12. Endoscopic approach for management of biliary strictures in liver transplant recipients: A systematic review and meta-analysis.

    Science.gov (United States)

    Aparício, Dayse Pereira da Silva; Otoch, José Pinhata; Montero, Edna Frasson de Souza; Khan, Muhammad Ali; Artifon, Everson Luiz de Almeida

    2017-10-01

    The most common biliary complication after liver transplantation is anastomotic stricture (AS) and it can occur isolated or in combination with other complications. Liver graft from a cadaveric donor or a living donor has an influence on the incidence of biliary strictures as well as on the response to endoscopic treatment. Endoscopic treatment using balloon dilation and insertion of biliary stents by endoscopic retrograde cholangiopancreatography (ERCP) is the initial approach to these complications. The aim of this article is to compare different endoscopic techniques to treat post-liver transplantation biliary strictures. The search was carried out on MEDLINE, EMBASE, Scielo-LILACS and Cochrane Library databases through June 2015. A total of 1100 articles were retrieved. Ten clinical trials were analyzed, and seven were included in the meta-analysis. The endoscopic treatment of AS was equally effective when compared the use of fully covered self-expandable metal stents (FCSEMS) vs. plastic stents, but the use of FCSEMS was associated with a lower complication risk. The treatment of AS with balloon dilation or balloon dilation associated with plastic stents presented similar results. Deceased donor liver transplantation reduced the risk of biliary stenosis and the endoscopic treatment in these patients was more effective when compared with Living donor liver transplantation.

  13. Ureteropelvic junction obstruction and ureteral strictures treated by simple high-pressure balloon dilation

    DEFF Research Database (Denmark)

    Osther, P J; Geertsen, U; Nielsen, H V

    1998-01-01

    congenital UPJO, previous stones, sequelae of endoscopic and open surgery, radiotherapy, and urinary tract reconstruction. A retrograde ureteroscopic approach was used. Evaluation included clinical and radiographic examinations and renal scintigraphy with diuretic wash-out. The procedure was repeated in 21......%, and in strictures secondary to reconstructive and ureteroscopic surgery, with a success rate of 91%. In congenital UPJO, the results were less encouraging: in patients with a symptom debut after the age of 18 years, balloon dilation was successful in 57% of cases; in patients with symptom debut before the age of 18...... years, success was achieved in only 25% of cases. There were no major complications. It was concluded that simple high-pressure balloon dilation is a safe and reasonably effective technique for the management of most ureteral strictures and congenital UPJO with symptom debut in adult life. Balloon...

  14. Endoscopic injection therapy

    Directory of Open Access Journals (Sweden)

    Sang Woon Kim

    2017-06-01

    Full Text Available Since the U.S. Food and Drug Administration approved dextranomer/hyaluronic acid copolymer (Deflux for the treatment of vesicoureteral reflux, endoscopic injection therapy using Deflux has become a popular alternative to open surgery and continuous antibiotic prophylaxis. Endoscopic correction with Deflux is minimally invasive, well tolerated, and provides cure rates approaching those of open surgery (i.e., approximately 80% in several studies. However, in recent years a less stringent approach to evaluating urinary tract infections (UTIs and concerns about long-term efficacy and complications associated with endoscopic injection have limited the use of this therapy. In addition, there is little evidence supporting the efficacy of endoscopic injection therapy in preventing UTIs and vesicoureteral reflux-related renal scarring. In this report, we reviewed the current literature regarding endoscopic injection therapy and provided an updated overview of this topic.

  15. Endoscopic injection therapy

    Science.gov (United States)

    Kim, Sang Woon; Lee, Yong Seung

    2017-01-01

    Since the U.S. Food and Drug Administration approved dextranomer/hyaluronic acid copolymer (Deflux) for the treatment of vesicoureteral reflux, endoscopic injection therapy using Deflux has become a popular alternative to open surgery and continuous antibiotic prophylaxis. Endoscopic correction with Deflux is minimally invasive, well tolerated, and provides cure rates approaching those of open surgery (i.e., approximately 80% in several studies). However, in recent years a less stringent approach to evaluating urinary tract infections (UTIs) and concerns about long-term efficacy and complications associated with endoscopic injection have limited the use of this therapy. In addition, there is little evidence supporting the efficacy of endoscopic injection therapy in preventing UTIs and vesicoureteral reflux-related renal scarring. In this report, we reviewed the current literature regarding endoscopic injection therapy and provided an updated overview of this topic. PMID:28612059

  16. Diagnostic and therapeutic double-balloon enteroscopy after small bowel Roux-en-Y reconstructive surgery.

    Science.gov (United States)

    Moreels, Tom G; Hubens, Guy J; Ysebaert, Dirk K; Op de Beeck, Bart; Pelckmans, Paul A

    2009-01-01

    Roux-en-Y reconstruction excludes the afferent limb and the biliopancreatic system from conventional endoscopic access. Postoperative problems in these excluded gastrointestinal systems are therefore often dealt with surgically. We investigated the usefulness of the therapeutic double-balloon enteroscope to perform interventional endoscopic procedures in the excluded segment of the gastrointestinal tract after Roux-en-Y reconstruction. 30 procedures were performed in 22 patients with Roux-en-Y reconstruction after enterobiliary anastomosis, gastrectomy or bariatric gastric bypass. All procedures were performed with the therapeutic double-balloon enteroscope, under general anesthesia and with fluoroscopic control. ERCP at the enterobiliary anastomosis was successful in 90% (n = 10) of the procedures. ERCP at the intact papilla was successful in 60% (n = 5). Enterocutaneous fistula closure after (sub)total gastrectomy was performed in 2 procedures. Successful diagnostic procedures encompassed intubation of the excluded stomach after bariatric gastric bypass (89%, n = 9) or the afferent limb after Roux-en-Y reconstruction (75%, n = 4). The overall success rate in accessing the aimed excluded segment with the double-balloon enteroscope was 87%. Interventional procedures were able to avoid surgery in 65%. One retroperitoneal perforation occurred during ERCP which was conservatively treated. Excluded gastrointestinal segments after Roux-en-Y reconstruction can be accessed with a substantial success rate using double-balloon enteroscopy. Therapeutic interventions like ERCP can prevent surgery in the majority of patients. Copyright 2009 S. Karger AG, Basel.

  17. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  18. US Daily Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Pilot Balloon observational forms for the United States. Taken by Weather Bureau and U.S. Army observers. Period of record 1918-1960. Records scanned from the NCDC...

  19. Retrieving Balloon Data in Flight

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Ultra Long Duration Balloon (ULDB) program will soon make flights lasting up to 100 days. Some flights may generate high data rates and retrieving this data...

  20. US Monthly Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Monthly winds aloft summary forms summarizing Pilot Balloon observational data for the United States. Generally labeled as Form 1114, and then transitioning to Form...

  1. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  2. Intragastric balloon treatment of obesity must be combined with bariatric surgery: a pilot study in Turkey.

    Science.gov (United States)

    Saruç, Murat; Böler, Deniz; Karaarslan, Mehmet; Baysal, Çağlar; Rasa, Kemal; Çakmakçi, Metin; Uras, Cihan; Tözün, Nurdan

    2010-12-01

    The treatment of morbid obesity by intragastric balloon (BioEnterics) placement is a safe and effective procedure. Cultural, social and economical factors are known to have an impact on the outcome of therapeutic interventions. This study aimed to evaluate the effect of this method on weight loss and long-term outcome following balloon removal in a cohort of Turkish patients. Twenty-five patients (11 male, 14 female) who selected BioEnterics intragastric balloon method for weight loss over surgery were included in the study. Their mean age was 35.2±13.4 and mean body mass index was 43.5±8.7 kg/m2. Patients who had any contraindication for endoscopic BioEnterics intragastric balloon placement were excluded. BioEnterics intragastric balloon was performed under deep sedation with propofol, and all patients were placed on a 1000 kcal/day diet for six months. Patients were reevaluated six months following balloon removal. Excess weight loss of greater than 25% was considered as end of treatment success. Maintenance of excess weight loss greater than 25% at the end of a six-month follow-up period was considered as long-term success. Results were reported as mean body mass index and mean %excess weight loss±SD. Statistical analysis was done using SPSS computer program. One patient was excluded from the study because of psychological intolerance (1/25) prompting early balloon removal. Twenty-four patients completed both the initial phase and the follow-up period. At the end of the initial six months, the mean body mass index was 35.7±4.6 kg/m2 and mean excess weight loss was 46.9±11.3%. Although 22 out of 24 patients (91.6%) had achieved end of treatment success, the mean body mass index was back to 41.9±7.7 kg/m2 at the end of the follow-up period. Only two patients were able to maintain excess weight loss of 25% at the completion of the study, resulting in a long-term success rate of 8.3%. BioEnterics intragastric balloon is a safe and effective but temporary

  3. NSAIDs-Related Pyloroduodenal Obstruction and Its Endoscopic Management

    Directory of Open Access Journals (Sweden)

    Mohd Talha Noor

    2011-01-01

    Full Text Available Endoscopic balloon dilatation (EBD has important role in the management of benign gastric outlet obstruction. Although there are many reports on the role of EBD in the management of corrosive-induced and peptic benign GOO, there is scanty data on its role in the management of NSAID-induced GOO. We report 10 cases of NSAID-induced pyloroduodenal obstruction and their endoscopic management. The most common site of involvement was duodenum (5/10 followed by both pylorus and duodenum (4/10 and pylorus (1/10. Most of the strictures were short web-like, and the mean (SD number of stricture was 2.0 (0.94. Endoscopic balloon dilatation was successful in 90% (9/10 cases requiring mean (SD of 2.0 (1.6 sessions of dilatation to achieve target diameter of 15 mm and mean (SD of 5.3 (2.7 sessions to maintain it over a treatment period of 4.5 months (IQR 2–15 months. There was no procedure-related complication or mortality.

  4. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis--Report of 7 Consecutive Patients with Serial ERC Approach.

    Directory of Open Access Journals (Sweden)

    Marija Stojkovic

    2016-02-01

    Full Text Available Biliary vessel pathology due to alveolar echicococcosis (AE results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography balloon dilation for AE biliary pathology.Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed.Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed "sustained clinical success" and four patients "assisted therapeutic success," of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS. There was no loss to follow up. No major complications were observed.Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current ERC guidelines and is minimally disruptive

  5. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis – Report of 7 Consecutive Patients with Serial ERC Approach

    Science.gov (United States)

    Stojkovic, Marija; Junghanss, Thomas; Veeser, Mira; Weber, Tim F.; Sauer, Peter

    2016-01-01

    Background and Aims Biliary vessel pathology due to alveolar echicococcosis (AE) results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography) balloon dilation for AE biliary pathology. Methods Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed. Results Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed “sustained clinical success” and four patients “assisted therapeutic success,” of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS). There was no loss to follow up. No major complications were observed. Conclusions Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current

  6. Endoscopic Treatment of Biliary Stenosis in Patients with Alveolar Echinococcosis--Report of 7 Consecutive Patients with Serial ERC Approach.

    Science.gov (United States)

    Stojkovic, Marija; Junghanss, Thomas; Veeser, Mira; Weber, Tim F; Sauer, Peter

    2016-02-01

    Biliary vessel pathology due to alveolar echicococcosis (AE) results in variable combinations of stenosis, necrosis and inflammation. Modern management strategies for patients with cholestasis are desperately needed. The aim is proof of principle of serial ERC (endoscopic retrograde cholangiography) balloon dilation for AE biliary pathology. Retrospective case series of seven consecutive patients with AE-associated biliary pathology and ERC treatment in an interdisciplinary endoscopy unit at a University Hospital which hosts a national echinococcosis treatment center. The AE patient cohort consists of 106 patients with AE of the liver of which 13 presented with cholestasis. 6/13 received bilio-digestive anastomosis and 7/13 patients were treated by ERC and are reported here. Biliary stricture balloon dilation was performed with 18-Fr balloons at the initial and with 24-Fr balloons at subsequent interventions. If indicated 10 Fr plastic stents were placed. Six patients were treated by repeated balloon dilation and stenting, one by stenting only. After an acute phase of 6 months with repeated balloon dilation, three patients showed "sustained clinical success" and four patients "assisted therapeutic success," of which one has not yet reached the six month endpoint. In one patient, sustained success could not be achieved despite repeated insertion of plastic stents and balloon dilation, but with temporary insertion of a fully covered self-expanding metal stent (FCSEMS). There was no loss to follow up. No major complications were observed. Serial endoscopic dilation is a standard tool in the treatment of benign biliary strictures. Serial endoscopic intervention with balloon dilation combined with benzimidazole treatment can re-establish and maintain biliary duct patency in AE associated pathology and probably contributes to avoid or postpone bilio-digestive anastomosis. This approach is in accordance with current ERC guidelines and is minimally disruptive for patients.

  7. Comparison between double-balloon and single-balloon enteroscopy in therapeutic ERC after Roux-en-Y entero-enteric anastomosis.

    Science.gov (United States)

    Moreels, Tom G; Pelckmans, Paul A

    2010-09-16

    To compare the efficacy of double-balloon enteroscopy (DBE) and single-balloon enteroscopy (SBE) in therapeutic endoscopic retrograde cholangiography (ERC) in patients with Roux-en-Y entero-enteric anastomosis. Retrospective analysis of our patient cohort revealed 4 patients with enterobiliary anastomosis and Roux-en-Y entero-enteric anastomosis who underwent repeated ERC with DBE and SBE because of recurrent cholangitis. A total of 38 endoscopic retrograde cholangiopancreatography procedures were performed in 25 patients with Roux-en-Y entero-enteric anastomosis. DBE was used in 29 procedures and SBE in 9. The 4 patients who underwent repeated ERC with DBE and SBE suffered from recurrent cholangitis due to stenosis of the enterobiliary anastomosis. ERC was performed repeatedly to achieve balloon dilation with/without biliary stone extraction and multiple stent placement at the level of the enterobiliary anastomosis. In all 4 patients DBE and SBE were equally successful. Compared to DBE, SBE was equally effective in passing the Roux-en-Y entero-enteric anastomosis, reaching the enterobiliary anastomosis and performing therapeutic ERC. This retrospective comparison shows that DBE and SBE are equally successful in the performance of therapeutic ERC at the level of the enterobiliary anastomosis after Roux-en-Y entero-enteric anastomosis.

  8. Esophageal per oral endoscopic myotomy (POEM) for achalasia: first case reported in Eastern Europe.

    Science.gov (United States)

    Tantau, Marcel; Tantau, Alina

    2013-12-01

    Traditional endoscopic treatment of achalasia consists of endoscopic balloon dilatation with the inconvenience of the recurrence of symptoms and the necessity of repeated sessions. Surgical laparoscopic procedure has been advocated to be more efficient especially in young patients because it sections the lower oesophageal sphincter via a transabdominal approach. The long term most severe complication has been refractory reflux oesophagitis due mainly to the alteration of the oesogastric antireflux anatomy (Hiss angle). Surgical myotomy was clasically associated with an antireflux procedure. Peroral endoscopic myotomy (POEM) via a mucosal orifice is as efficient as surgical myotomy but the antireflux anatomy of gastroesophageal junction is not altered, so the reflux symptoms are reduced. Second, POEM is mini invasive in comparison with laparoscopic surgery. The paper presents our first and successful case of this endoscopic surgical procedure in a 41 year old patient.

  9. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  10. Environmental effects of the US Antarctic Program`s use of balloons in Antarctica

    Energy Technology Data Exchange (ETDEWEB)

    McCold, L.N.; Eddlemon, G.K.; Blasing, T.J.

    1995-06-01

    The USAP uses balloons in Antarctica to conduct scientific research, to facilitate safe air transport, and to provide data for global weather predictions. However, there is the possibility that balloons or their payloads may adversely affect Antarctic fauna or flora. The purpose of this study is to provide background information upon which the USAP may draw when complying with its responsibilities under the National Environmental Policy Act of 1969, the Antarctic Treaty, and the Madrid Protocol.

  11. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-01-01

    The NASA Balloon Program (BP) is examined in an overview of design philosophy, R&D activities, flight testing, and the development of a long-duration balloon for Antarctic use. The Balloon Recovery Program was developed to qualify the use of existing films and to design improved materials and seals. Balloon flights are described for studying the supernova SN1987a, and systems were developed to enhance balloon campaigns including mobile launch vehicles and tracking/data-acquisition systems. The technical approach to long-duration ballooning is reviewed which allows the use of payloads of up to 1350 kg for two to three weeks. The BP is responsible for the development of several candidate polyethylene balloon films as well as design/performance standards for candidate balloons. Specific progress is noted in reliability and in R&D with respect to optimization of structural design, resin blending, and extrusion.

  12. Acoustic Detection from Aerial Balloon Platform

    National Research Council Canada - National Science Library

    Reiff, C; Pham, T; Scanlon, M; Noble, J; Van Landuyt, A; Petek, J; Ratches, J

    2004-01-01

    ... such as unmanned aerial vehicles (UAVs) and balloons. Our most immediate collaboration focuses on the use of acoustic sensors on small balloons and/or aerostats at several elevations and on the ground with the primary goals...

  13. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  14. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  15. Per-oral endoscopic myotomy: emerging indications and evolving techniques.

    Science.gov (United States)

    Minami, Hitomi; Inoue, Haruhiro; Haji, Amyn; Isomoto, Hajime; Urabe, Shigetoshi; Hashiguchi, Keiichi; Matsushima, Kayoko; Akazawa, Yuko; Yamaguchi, Naoyuki; Ohnita, Ken; Takeshima, Fuminao; Nakao, Kazuhiko

    2015-01-01

    Esophageal achalasia is a benign esophageal motility disorder resulting from an impaired relaxation of the lower esophageal sphincter. The principles of treatment involve disruption of the sphincter at the esophagogastric junction. Treatment techniques include balloon dilatation, botulinum toxin injection, and surgical myotomy. In 2008, per-oral endoscopic myotomy (POEM) was introduced by Inoue et al. as an endoscopic myotomy with no skin incision. The procedure has been well accepted and widely applied owing to its minimal invasiveness and high cure rates. Moreover, there have been discussions on wider indications for POEM and new technical developments have been reported. The present article reviews the historical background and present status of POEM, as well as future prospects for its application in the treatment of esophageal achalasia. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  16. [Lugol's solution in endoscopic diagnosis of early esophageal cancer].

    Science.gov (United States)

    Wang, G; Zhou, M; Cong, Q

    1995-07-01

    About 1500 high-risk subjects of esophageal cancer were found during screening by balloon cytology and all of them were examined endoscopically. Among them, 120 were considered as having early esophageal cancer and precancerous lesions. During the examination, Lugol's solution staining was used and guiding biopsy was taken. 98 subjects with unstained lesions were found, and biopsy showed early esophageal cancer in 60 (61.2%) and moderate and severe dysplasia in 38 (38.8%). It is usually extremely difficult to detect and localize the very early esophageal mucosal and submucosal carcinoma. But endoscopic examination and using Lugol's solution staining with multiple spots biopsy from unstained area are of great assistance. Minute malignant lesions may not be overlooked.

  17. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  18. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    Science.gov (United States)

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  19. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  20. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  1. Balloon dilatation biopsy of the biliary stricture through the percutaneous transhepatic biliary drainage tract: Feasibility and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Ji Hoon; Ryeom, Hun Kyu; Jang, Yun Jin; Kim, Gab Chul; Cho, Seung Hyun; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2016-01-15

    To evaluate the feasibility and diagnostic accuracy of the balloon dilatation biopsy for the biliary stricture through the percutaneous transhepatic biliary drainage (PTBD) tract. The study included 35 patients who underwent balloon dilatation biopsy for the biliary stricture through the PTBD tract. Balloon dilatation was done with a balloon catheter of 10-mm or 12-mm diameter. Soft tissue adherent to the retrieved balloon catheter and soft tissue components separated by gauze filtration of evacuated bile were sampled for histopathologic examination. The results were compared with the final diagnosis which was made by clinical and imaging follow-up for mean 989 days (n = 34) and surgery with histopathologic examination (n = 1). Procedure-related complications and diagnostic accuracy were assessed. Tissues suitable for histopathologic examination were obtained in 31 out of 35 patients (88.6%). In 3 patients, self-limiting hemobilia was noted. No major complication was noted. The sensitivity, specificity, diagnostic accuracy, positive and negative predictive values for diagnosis of malignant stricture were 70.0%, 100%, 90.3%, 100%, and 87.5%, respectively. Balloon dilatation biopsy of the biliary stricture through the PTBD tract is a feasible and accurate diagnostic method. It can be a safe alternative to the endoscopic retrograde cholangiography biopsy or forceps biopsy through the PTBD tract.

  2. Scientific ballooning: Past, present and future

    Science.gov (United States)

    Jones, W. Vernon

    2013-02-01

    Balloons have been used for scientific research since they were invented in France more than 200 years ago. Cosmic rays were discovered 100 years ago with an experiment flown on a manned balloon. A major change in balloon design occurred in 1950 with the introduction of the socalled natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for the past half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing a super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. Ultra-long-duration balloon (ULDB) flights enabled by constant-volume balloons should result in an even greater sea change in scientific ballooning than the inauguration of long-duration balloon (LDB) flights in Antarctica during the 1990-91 austral summer.

  3. Endoscopic computerized tomography guided percutaneous trans-gastric drainage: A case report on this hybrid approach

    OpenAIRE

    Tsutsui, Nobuhiro; Suzuki, Yutaka; Saito, Nobuhiro; Ohdaira, Hironori; Yamanouchi, Eigoro; Yoshida, Masashi

    2016-01-01

    Percutaneous drainage, percutaneous transgastric drainage, and endoscopic ultrasound (EUS)-guided transgastric drainage are primarily utilized for drainage of fluid collections dorsal to the stomach. Percutaneous transgastric drainage is performed with computed tomography (CT) guidance, but it requires inflation of a balloon in the stomach, and gastric peristalsis makes it difficult to ensure a reliable puncture route via the stomach. Using endoscopy-assisted CT-guidance, we were able to safe...

  4. Tertiary center experience with primary endoscopic laryngoplasty in pediatric acquired subglottic stenosis and literature review

    Directory of Open Access Journals (Sweden)

    Jaber Alshammari

    2017-03-01

    Conclusion: Our study showed that primary endoscopic management was successful in 82.3% of cases of acquired subglottic stenosis including those with high grade stenosis and long segment of more than 12 mm in terms of the craniocaudal length. CO2 laser was an important tool to convert mature hard stenotic segment into a soft one. The latter yielded to the lateral pressure created by balloon dilatation better.

  5. Endoscopic management of colorectal adenomas.

    Science.gov (United States)

    Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur

    2017-01-01

    Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy.

  6. Development of scientific ballooning in Japan

    Science.gov (United States)

    Nishimura, Jun

    On the occasion of the 50th Anniversary Celebration of COSPAR of this year of 2008, it is worthwhile to summarize the results of the Scientific ballooning in early days in connection with the recent developments in various countries. Nishina Laboratories, Riken, had started the observations of cosmic rays with rubber balloons as early as 1942. However it was interrupted soon by the war II. After the war, new research group started in collaboration with several universities with nuclear emulsions put on the rubber balloons in 1950, and then soon after the group manufactured by themselves and launched the first plastic balloon in 1953. Based on additional technologies during a few years developed by these group, the Institute of Nuclear Study, INS, the University of Tokyo, organized the large campaign of 14 emulsion chambers and a pellicle stack with 8 plastic balloons in 1956. It is to be noted that the project was one of the largest in the world standard in those days. By the experience of this campaign, the importance of the balloon technologies was more recognized, and INS organized the group to study the balloon technologies, and had established some developments. The systematic study of scientific ballooning has started, when the scientific ballooning laboratory was founded in 1965, in the new Institute of ISAS, the University of Tokyo. The permanent balloon base of "Sanriku Balloon Center" was founded in 1971. This group has expended all efforts for the scientific ballooning, launching 10-20 balloons in each year with new inventions such as the studies of; Technologies to manufacture the reliable plastic balloons, New Balloon materials, New instrumentations for scientific ballooning, Systems of long duration flights including Antarctica flights, International collaboratiom, etc. Up to now almost 600 plastic balloons were launched during past 50 years. Then the scientific balloonings have played important and indispensable roles for the development of space

  7. Comparison of microscopic and endoscopic view of the internal acoustic meatus: A cadaveric study.

    Science.gov (United States)

    Montibeller, Guilherme Ramina; Hendrix, Philipp; Fries, Fabian N; Becker, Kurt W; Oertel, Joachim

    2018-04-01

    The endoscope is thought to provide an improved exposure of the internal acoustic meatus after retrosigmoid craniotomy for microsurgical resection of intrameatal tumors. The aim of this study is to quantify the differences in internal acoustic meatus (IAM) exposure comparing microscopic and endoscopic visualization. A retrosigmoid approach was performed on 5 cadaver heads. A millimeter gauge was introduced into the internal acoustic meatus, and examinations with a surgical microscope and 0°, 30° and 70° rigid endoscopes were performed. The extent of IAM depth visualized with the microscope and the different angled endoscopes were analyzed. The microscopic view allowed an average IAM depth visualization of 2.8 mm. The endoscope allowed an improved exposure of IAM in all cases. The 0°, 30° and 70° endoscopes permitted an exposure that was respectively 96% (5.5 mm), 139% (6.7 mm) and 200% (8.4 mm) more lateral than the microscopic view. Angled optics, however, provided an image distortion, specifically the 70° endoscope. The endoscope provides a superior visualization of the IAM compared to the microscope when using a retrosigmoid approach. The 30° endoscope represented an ideal compromise of superior visualization with marginal image distortion. Additional implementation of the endoscope into microsurgery of intrameatal tumors likely facilitates complete tumor removal and might spare facial and vestibulocochlear function. Clin. Anat. 31:398-403, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. [Large balloon dilation for removal of choledocholithiasis difficult to extract: clinical experience].

    Science.gov (United States)

    Marin Calderón, Luis; Vera Calderón, Augusto; Gómez Correa, Aldo; Cervera Reyes, Zenon; Dávalos Moscol, Milagros; Alva Alva, Edgar; Palacios Salas, Fernando; Díaz Ríos, Ramiro; Guzmán Calderón, Edson; García Chihuan, Grisley

    2016-01-01

    The aim of this study was to report the initial experience of the combined use of biliary sphincterotomy plus balloon dilatation of the papilla for management of large stones. Design: Retrospective, descriptive. This study included 18 patients in whom a hydrostatic dilatation of the papilla with large balloons was performed between June 2012 and April 2014. Patients had multiple large stones, tapered distal common bile duct, previous sphincterotomy, or peri/ intradiverticular papilla. CRE™ dilatation balloons with diameters ranging from 12 to 20 mm were used. Data were recorded as successful procedure, use of lithotripsy and complications during the procedure. The average age was 66.1 years. There was a predominance of the female gender (66.7%). The average size of the bile duct stones was 16.7 mm. The main indications were: giant choledocholithiasis (12 patients, 66.7%) and tapered distal common bile duct (6 patients, 33.3%). The dilatation balloons diameter used were: 15 mm (8 patients, 44.4%), 18 mm (5 patients, 27.8%), 12 mm (3 patients, 16.7%) and 20 mm (2 patients, 11.1%). Complete stone clearance was achieved in 15 patients (83.3%). Lithotripsy was performed in 4 patients (22.2%). There were 3 patients in whom the removal with balloon was unsuccessful, performed surgical management. It was reported 1 case of mild acute pancreatitis (5.5%). The results show that endoscopic papillary large balloon dilation after sphincterotomy is a safe and effective technique for treatment of difficult bile duct stones.

  9. Palliation of malignant gastric outlet obstruction with simultaneous endoscopic insertion of afferent and efferent jejunal limb enteral stents in patients with recurrent malignancy.

    Science.gov (United States)

    Soo, Isaac; Gerdes, Hans; Markowitz, Arnold J; Mendelsohn, Robin B; Ludwig, Emmy; Shah, Pari; Schattner, Mark A

    2016-02-01

    Patients with prior pancreaticobiliary or distal gastric cancer treated surgically may have local anastomotic recurrence with obstruction of the afferent and efferent jejunal limbs. This report describes the efficacy and safety of simultaneous endoscopic insertion of self-expanding metal stents into the afferent and efferent jejunal limbs in patients with gastric outlet obstruction (GOO) of post-surgical anatomy for palliation of recurrent malignancy. Patients were identified from an endoscopic database at a specialized cancer center between September 2007 and March 2014. Technical success was defined as single-session insertion of afferent and efferent jejunal limb enteral stents. Clinical success was defined as immediate symptom relief and ability to advance diet. A durable response was defined as symptom relief of at least 60 days or until hospice placement or death. Twenty-three patients were identified who underwent insertion of two 22-mm-diameter uncovered duodenal stents. Stent length varied from 60 to 120 mm. Stents were placed under endoscopic and fluoroscopic guidance. Three patients required balloon dilation to facilitate stent insertion. Average procedure time was 58.8 min (range 28-120). Technical success was achieved in 23/24 (96%) patients. Clinical success was achieved in 19/23 (83%) patients. Following initial stent insertion and prior to subsequent re-intervention, 11/19 (58%) patients had a durable response with a median duration of 70 days (range 4-315). Eight (42%) patients underwent subsequent re-intervention at a median of 22 days (range 11-315). Five patients had stent revision and were able to tolerate oral intake. Two patients had percutaneous endoscopic gastrostomy/jejunostomy insertion. One patient required surgical diversion for persistent obstruction. Complications included stent migration and post-stent insertion bacteremia due to food bolus obstruction. Recurrent malignant GOO in patients with post-surgical anatomy treated with

  10. PEBS - Positron Electron Balloon Spectrometer

    CERN Document Server

    von Doetinchem, P.; Kirn, T.; Yearwood, G.Roper; Schael, S.

    2007-01-01

    The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was needed to design a detector which could increase the existing data by more than a factor of 100. Using silicon photomultipliers for the readout of a scintillating fiber tracker and of an imaging electromagnetic calorimeter, the PEBS detector features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total weight of 1500 kg and a power consumption of 600 W. The experiment is intended to measure cosmic ray particle spectra for a period of up to 20 days at an altitude of 40 km circulating the North or South Pole. A full Geant 4 simulation of the detector concept has been developed and key elements have been verified in a testbeam in October 2006 at CERN.

  11. Automated endoscope reprocessors.

    Science.gov (United States)

    Desilets, David; Kaul, Vivek; Tierney, William M; Banerjee, Subhas; Diehl, David L; Farraye, Francis A; Kethu, Sripathi R; Kwon, Richard S; Mamula, Petar; Pedrosa, Marcos C; Rodriguez, Sarah A; Wong Kee Song, Louis-Michel

    2010-10-01

    The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through February 2010 for articles related to automated endoscope reprocessors, using the words endoscope reprocessing, endoscope cleaning, automated endoscope reprocessors, and high-level disinfection. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Left ventricular apical ballooning syndrome

    International Nuclear Information System (INIS)

    Rahman, N.; Tai, J.; Soofi, A.

    2007-01-01

    The transient left ventricular apical ballooning syndrome, also known as Takotsubo cardiomyopathy, is characterized by transient left ventricular dysfunction in the absence of obstructive epicardial coronary disease. Although the syndrome has been reported in Japan since 1990, it is rare in other regions. Rapid recognition of the syndrome can modify the diagnostic and therapeutic attitude i.e. avoiding thrombolysis and performing catheterization in the acute phase. (author)

  13. Gastric Ulcer Hemorrhage - a Potential Life-Threatening Complication of Intragastric Balloon Treatment of Obesity

    Directory of Open Access Journals (Sweden)

    Aleksandra Mojkowska

    2017-04-01

    Full Text Available Background: Some morbidly obese patients do not qualify for bariatric surgery due to general health contraindications. Intragastric balloon treatment might be a therapeutic option in the above-mentioned cases. It can prime super-obese patients with end-stage disease for bariatric surgery. As a neoadjuvant therapy before surgery, it leads to a downstage of the disease by preliminary weight reduction, to an improvement in general health and, in summary, to a reduction of the perioperative risk. It is generally considered to be a safe method. However, due to the wide range of possible complications and unusual symptoms after intragastric balloon treatment, an interdisciplinary, instead of only a surgical or endoscopic, treatment and follow-up might be recommended in these patients. Case Report: We here describe a potential life-threatening complication in the form of gastric bleeding as a consequence of intragastric balloon treatment and simultaneous aspirin taking and Helicobacter pylori infection. Conclusion: There have been reports of some complications of intragastric balloon treatment. However, to the best of our knowledge there were no reports concerning life-threatening hemorrhage from gastric ulcer.

  14. Design of an everting balloon to deploy a microendoscope to the fallopian tubes

    Science.gov (United States)

    Keenan, Molly; Howard, Caitlin; Tate, Tyler; McGuiness, Ian; Sauer-Budge, Alexis; Black, John; Utzinger, Urs; Barton, Jennifer K.

    2016-02-01

    The 5-year survival rate for ovarian cancer is only 45% largely due to lack of effective screening methods. Current methods include palpation, transvaginal ultrasound, and the CA-125 blood test. Finding disease reliably and at an early stage increase survival to 92%. We have designed and built a 0.7 mm endoscope for the early detection of ovarian cancer. Inserted transvaginally through the working channel of a hysteroscope, the falloposcope creates a minimally invasive procedure for the screening of high risk women. To improve the ease-of-use and safety of falloposcope deployment, we are working to create an everting balloon. Currently, the falloposcope would require a skilled user to operate due to the challenging anatomy of the fallopian tubes - a small opening from the uterus (< 1 mm), tortuous path, and delicate lumenal features. A balloon delivery system would gently open the fallopian tube and guide the falloposcope down the center of lumen. We show balloon design and discuss integration with the falloposcope prototype. We test possible mechanical damage to the tissue due to scraping, puncture, or overstretching. Successful introduction of the everting balloon to simplify falloposcope delivery could expand screening beyond specialized centers to smaller clinical locations.

  15. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  16. Ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Huysmans, G.T.A.; Goedbloed, J.P.; Galvao, R.M.O.; Lazzaro, E.; Smeulders, P.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, extremely large pressure gradients have been produced in the plasma core through pellet injections in the current rise phase followed by strong additional heating. In the second type, the total pressure of the discharge is approaching the Troyon limit. The stability of these discharges with respect to the ideal MHD ballooning modes has been studied with the stability code HBT. The equilibria are reconstructed with the IDENTC code using the external magnetic measurements and the experimental pressure profile. The results show that the evaluated high beta discharge is unstable in the central region of the plasma. This instability is related to the low shear and not to a large pressure gradient, as expected at the Troyon limit. In the pellet discharges the regions with the large pressure gradients are unstable to ballooning modes at the time of the beta decay, which ends the period of enhanced performance. The maximum pressure gradient in these discharges is limited by the boundary of the first region of stability. The observed phenomena at the beta decay are similar to those observed at the beta limit in DIII-D and TFTR. (author)

  17. Stricture Occurring after Endoscopic Submucosal Dissection for Esophageal and Gastric Tumors

    Science.gov (United States)

    Kim, Gwang Ha; Jang, Jae Young; Shin, Sung Kwan; Choi, Kee Don; Lee, Jun Haeng; Kim, Sang Gyun; Sung, Jae Kyu; Choi, Suck Chei; Jeon, Seong Woo; Jang, Byung Ik; Huh, Kyu Chan; Chang, Dong Kyung; Jung, Sung-Ae; Keum, Bora; Cho, Jin Woong; Choi, Il Ju; Jung, Hwoon-Yong

    2014-01-01

    Endoscopic submucosal dissection (ESD) is a widely accepted treatment for early gastric and esophageal cancer. Compared to endoscopic mucosal resection, ESD has the advantage of enabling en bloc removal of tumors regardless of their size. However, ESD can result in a large artificial ulcer, which may lead to a considerable deformity. Circumferential mucosal defects of more than three-fourths the esophageal circumference, long longitudinal mucosal defects (>30 mm), and lesions in the upper esophagus are significant risk factors for the development of post-ESD strictures of the esophagus. In the stomach, a circumferential mucosal defects more than three-fourths in extent and longitudinal mucosal defects >5 cm are risk factors of post-ESD stricture. If scheduled early, regular endoscopic balloon dilation is effective in controlling and preventing post-ESD stricture. Moreover, intralesional steroid injections or oral steroids can achieve remission of dysphagia or reduce the need for repeated endoscopic balloon dilation. However, further study is needed to improve the prevention of stricture formation. PMID:25505717

  18. Endoscopic management of bile duct stones in patients with surgically altered anatomy.

    Science.gov (United States)

    Nakai, Yousuke; Kogure, Hirofumi; Yamada, Atsuo; Isayama, Hiroyuki; Koike, Kazuhiko

    2018-04-01

    Bile duct stones in patients with surgically altered anatomy still pose a challenge to endoscopists. For successful endoscopic management of bile duct stones, there are multiple hurdles: Intubation to the afferent limb, biliary cannulation, ampullary intervention and stone extraction. The major advancement in this area is the development of dedicated device-assisted endoscopes for endoscopic retrograde cholangiopancreatography (ERCP). In patients with Billroth II reconstruction, a high technical success rate is reported using a duodenoscope but can be complicated by a potentially high perforation rate. In patients with Roux-en-Y reconstruction, device-assisted ERCP shows high technical success and low adverse event rates. Meanwhile, endoscopic papillary large balloon dilation enables safe and effective stone extraction with less use of endoscopic mechanical lithotripsy in patients with a dilated distal bile duct, but intraductal lithotripsy is sometimes necessary for management of very large bile duct stones. In cases with difficult stones, alternative approaches such as laparoscopy-assisted ERCP and endoscopic ultrasound (EUS)-guided intervention are increasingly reported with preliminary but promising results. However, comparative studies are still lacking in this area and prospective randomized controlled trials are warranted in terms of safety, efficacy and cost-effectiveness. © 2018 Japan Gastroenterological Endoscopy Society.

  19. Endoscope-magnetic tracker calibration via trust region optimization

    Science.gov (United States)

    Sargent, Dusty

    2010-02-01

    Minimally invasive surgical techniques and advanced imaging systems are gaining prevalence in modern clinical practice. Using miniaturized magnetic trackers in combination with these procedures can help physicians with the orientation and guidance of instruments in graphical displays, navigation during surgery, 3D reconstruction of anatomy, and other applications. Magnetic trackers are often used in conjunction with other sensors or instruments such as endoscopes and optical trackers. In such applications, complex calibration procedures are required to align the coordinate systems of the different devices in order to produce accurate results. Unfortunately, current calibration procedures developed for augmented reality are cumbersome and unsuitable for repeated use in a clinical setting. This paper presents an efficient automated endoscope-tracker calibration algorithm for clinical applications. The algorithm is based on a state-of-the-art trust region optimization method and requires minimal intervention from the endoscope operator. The only required input is a short video of a calibration grid taken with the endoscope and attached magnetic tracker prior to the procedure. The three stage calibration process uses a traditional camera calibration to determine the intrinsic and extrinsic parameters of the endoscope, and then the endoscope is registered in the tracker's reference frame using a novel linear estimation method and a trust region optimization algorithm. This innovative method eliminates the need for complicated calibration procedures and facilitates the use of magnetic tracking devices in clinical settings.

  20. Choledocholithiasis diagnostics – endoscopic ultrasound or endoscopic retrograde cholangiopancreatography?

    Directory of Open Access Journals (Sweden)

    Jarosław Leszczyszyn

    2014-06-01

    Full Text Available It is estimated that 3.4% of patients qualified for cholecystectomy due to cholelithiasis have a coexisting choledocholithiasis. For decades, endoscopic ascending retrograde cholangiopancreatography has been the golden diagnostic standard in cases of suspected choledocholithiasis. The method is associated with a relatively high rate of complications, including acute pancreatitis, the incidence of which is estimated to range between 0.74% and 1.86%. The mechanism of this ERCP-induced complication is not fully understood, although factors increasing the risk of acute pancreatitis, such as sphincter of Oddi dysfunction, previous acute pancreatitis, narrow bile ducts or difficult catheterization of Vater’s ampulla are known. It has been suggested to discontinue the diagnostic endoscopic retrograde ascending cholangiopancreatography and replace it with endoscopic ultrasonography due to possible and potentially dangerous complications. Endoscopic ultrasonography has sensitivity of 94% and specificity of 95% regardless of gallstone diameter, as opposed to magnetic resonance cholangiography. However, both of these parameters depend on the experience of the performing physician. The use of endoscopic ultrasonography allows to limit the number of performed endoscopic retrograde cholangiopancreatography procedures by more than 2/3. Ascending endoscopic retrograde cholangiopancreatography combined with an endoscopic incision into the Vater’s ampulla followed by a mechanical evacuation of stone deposits from the ducts still remains a golden standard in the treatment of choledocholithiasis. Despite some limitations such as potentially increased treatment costs as well as the necessity of the procedure to be performed by a surgeon experienced in both endoscopic retrograde cholangiopancreatography as well as endoscopic ultrasonography, the diagnostic endoscopic ultrasonography followed by a simultaneous endoscopic retrograde cholangiopancreatography

  1. Titan Balloon Convection Model, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  2. Current trends of balloon laryngoplasty in Thailand.

    Science.gov (United States)

    Moungthong, Greetha; Bunbanjerdsuk, Sacarin; Wright, Nida; Sathavornmanee, Thanakrit; Setabutr, Dhave

    2017-06-01

    To describe the current trend in balloon laryngoplasty usage and experience by practicing otolaryngologists in Thailand. Anonymous 11 question online and paper survey of otolaryngologists on their current balloon laryngoplasty practices. Current practices and experience in balloon laryngoplasty were queried with multiple choice and open-ended questions. Laser use is the most commonly utilized instrument to treat airway stenosis in Thailand. 86% of respondents do not have experience with balloon dilatation; yet, almost half (47.6%) report they perform a minimum of five airway surgeries per year. Most respondents had been in practice for less than 6 years (41%) and reported that they did not have exposure to balloon use during residency training. The largest barrier reported for the use of balloon instrumentation in the airway is inexperience (44.4%) followed by cost (38.3%), yet most feel that treatment in airway stenosis could benefit by usage of balloons (95.5%). Most otolaryngologists in Thailand do not have experience with the use of balloon dilatation and lack of exposure remains the largest barrier to its use. Otolaryngologists in Thailand feel that increased usage of balloons in the airway could improve airway stenosis treatment in the country.

  3. [GERD: endoscopic antireflux therapies].

    Science.gov (United States)

    Caca, K

    2006-08-02

    A couple of minimally-invasive, endoscopic antireflux procedures have been developed during the last years. Beside endoscopic suturing these included injection/implantation technique of biopolymers and application of radiofrequency. Radiofrequency (Stretta) has proved only a very modest effect, while implantation techniques have been abandoned due to lack of long-term efficacy (Gatekeeper) or serious side effects (Enteryx). While first generation endoluminal suturing techniques (EndoCinch, ESD) demonstrated a proof of principle their lack of durability, due to suture loss, led to the development of a potentially durable transmural plication technique (Plicator). In a prospective-randomized, sham-controlled trial the Plicator procedure proved superiority concerning reflux symptoms, medication use and esophageal acid exposure (24-h-pH-metry). While long-term data have to be awaited to draw final conclusions, technical improvements will drive innovation in this field.

  4. [Functional endoscopic sinus surgery].

    Science.gov (United States)

    Han, D M

    1992-01-01

    Eighty-two cases of functional endoscopic sinus surgery were analyzed. It include 62 males and 20 females; the oldest was 72 years of age and the youngest eight years of age. A hard endoscope with a diameter of 4mm and the CCD micro-videorecorder produced by Circon and Olympus Company were used. Operations were done under general anesthesia in all cases. Twenty-three cases (28.1%) recovered in one stage and recovery was delayed in 28 cases (34.2%); late inflammation occurred in 23 cases (28.1%); 8 cases failed (9.8%). The cure rate was 62.2%. Two cases (2.4%) had operative complications namely injury to the lamina papyracea and anterior ethmoidal artery, all recovered uneventfully.

  5. Novel methods for endoscopic training.

    Science.gov (United States)

    Gessner, C E; Jowell, P S; Baillie, J

    1995-04-01

    The development of past, present, and future endoscopic training methods is described. A historical perspective of endoscopy training guidelines and devices is used to demonstrate support for the use of novel endoscopic training techniques. Computer simulation of endoscopy, interactive learning, and virtual reality applications in endoscopy and surgery are reviewed. The goals of endoscopic simulation and challenges facing investigators in this field are discussed, with an emphasis on current and future research.

  6. Endoscopic tissue diagnosis of cholangiocarcinoma.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2008-09-01

    The extremely poor outcome in patients with cholangiocarcinoma, in large part, reflects the late presentation of these tumors and the challenging nature of establishing a tissue diagnosis. Establishing a diagnosis of cholangiocarcinoma requires obtaining evidence of malignancy from sampling of the epithelium of the biliary tract, which has proven to be challenging. Although endoscopic ultrasound-guided fine needle aspiration performs slightly better than endoscopic retrograde cholangiopancreatography in diagnosing cholangiocarcinoma, both endoscopic approaches demonstrate disappointing performance characteristics.

  7. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  8. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De

    1990-01-01

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  9. Successful Endoscopic Treatment of Severe Pancreaticojejunostomy Strictures by Puncturing the Anastomotic Site with an EUS-guided Guidewire

    Science.gov (United States)

    Nabeshima, Tatsuhide; Kanno, Atsushi; Masamune, Atsushi; Hayashi, Hiroki; Hongo, Seiji; Yoshida, Naoki; Nakano, Eriko; Miura, Shin; Hamada, Shin; Kikuta, Kazuhiro; Kume, Kiyoshi; Hirota, Morihisa; Unno, Michiaki; Shimosegawa, Tooru

    2017-01-01

    Pancreaticojejunostomy stricture (PJS) is a late complication of pancreaticoduodenectomy. The endoscopic treatment of PJS is very challenging due to the difficulty of locating the small anastomotic site and passing the stricture using a guidewire. We herein report two cases of severe PJS. These patients could not be treated using only double-balloon endoscopy or endoscopic ultrasound-guided puncture of the main pancreatic duct because of severe stenosis at the anastomotic site. However, we could treat them by the rendezvous technique using the rigid part of the guidewire to penetrate PJS. This method was useful and safe for treating severe PJS. PMID:29151507

  10. Simulation of stratospheric balloon environment

    International Nuclear Information System (INIS)

    Sable, C.

    1974-01-01

    The behavior of materials used for the construction of stratospheric balloons is studied at DERTS by means of irradiations performed in reals time and simulating the exact flight environment. Two chambers were designed in the laboratory and are described together with the experimental procedure. In order to reduce cost and save time, it is worth accelerating the simulation when only a preliminary evaluation of the sample's properties is required. For this reason, a systematic study was undertaken in order to evaluate the respective effects of different parameters on the material degradation. The results of this study are given [fr

  11. Pure NOTES rectosigmoid resection: transgastric endoscopic IMA dissection and transanal rectal mobilization in animal models.

    Science.gov (United States)

    Park, Sun Jin; Lee, Kil Yeon; Choi, Sung Il; Kang, Byung Mo; Huh, Chang; Choi, Dong Hyun; Lee, Chang Kyun

    2013-07-01

    We report a pure natural orifice translumenal endoscopic surgery (NOTES(®); American Society for Gastrointestinal Endoscopy [Oak Brook, IL] and the Society of American Gastrointestinal and Endoscopic Surgeons [Los Angeles, CA]) rectosigmoidectomy in animal models using transgastric endoscopic inferior mesenteric artery (IMA) dissection and transanal rectal mobilization. Ten live animals (2 pigs weighing 35-40 kg each and 8 dogs weighing 25-30 kg each) were used. A gastrotomy was made using a needle-knife puncture and the balloon dilatation technique or following the creation of a submucosal tunnel. A circular stapler shaft was transanally inserted up to the sigmoid colon for spatial orientation and traction of the mesocolon. The IMA was endoscopically dissected using a Coagrasper™ (Olympus, Tokyo, Japan) and then clipped. Endoscopic division of the sigmoid mesocolon was conducted laterally toward the marginal artery. Transanal full-thickness circumferential rectal and mesorectal dissections were performed, and a colorectal anastomosis was performed using a circular stapler with a single stapling technique. During the transanal approach, the gastrotomy was closed using four endoscopic clips. Endoscopic dissection of the IMA was successful in all cases, but minor bleedings occurred in 3 cases. The mean time from dissection and clipping to division of the IMA was 36.7 minutes (range, 25-45 minutes). The mean operation time was 180.5 minutes (range, 145-210 minutes). There were no intraoperative complications or hemodynamic instability. The mean length of the resected specimen was 11.2 cm (range, 9-17 cm). A pure NOTES approach to rectosigmoid resection using transgastric endoscopic IMA dissection is technically feasible in animal models.

  12. Balloon dilatation of iatrogenic urethral strictures

    International Nuclear Information System (INIS)

    Acunas, B.; Acunas, G.; Gokmen, E.; Celik, L.

    1988-01-01

    Balloon dilatation of the urethra was performed in five patients with iatrogenic urethral strictures. The urethral strictures were successfully negotiated and dilated in all patients. Redilatation became necessary in a period ranging from 3 to 10 months. The authors believe that balloon dilatation of the urethra can be safely and successfully performed; the procedure produces minimal trauma and immediate relief of symptoms. (orig.)

  13. Percutaneous balloon dilatation for benign hepaticojejunostomy strictures

    NARCIS (Netherlands)

    Vos, P. M.; van Beek, E. J.; Smits, N. J.; Rauws, E. A.; Gouma, D. J.; Reeders, J. W.

    2000-01-01

    BACKGROUND: Percutaneous balloon dilatation of biliary tract strictures is generally accepted as a safe and inexpensive procedure. The effectiveness in selected groups of patients remains under discussion. The purpose of this study was to evaluate the results of percutaneous balloon dilatation in

  14. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  15. Balloon-occluded retrograde transvenous obliteration for gastric variceal bleeding patient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Seong, Chang Kyu; Kim, Yong Joo; Park, Noh Hyuk [Kyungpook National University School of Medicine, Daegu (Korea, Republic of); Shin, Tae Beom [Dong-A University Medical Center, Pusan (Korea, Republic of); Choi, Jin Soo [Soonchunhyang University College of Medicine, Asan (Korea, Republic of)

    2003-03-01

    To evaluate the technical feasibility and clinical efficacy of balloon-occluded retrograde transvenous obliteration (BRTO) in the treatment of gastric variceal bleeding. Between September 2001 and March 2002, ten patients with gastric variceal bleeding and gastrorenal shunt, underwent BRTO. Three of the ten also had hepatic encephalopathy. To evaluated the gastrorenal shunt and exclude portal vein thrombosis, all patients underwent pre-procedural CT scanning. An occlusion balloon catheter was inserted from the right internal jugular vein and on ballooning was wedged into the left adrenal vein. A sclerosing agent (5% ethanolamine oleate-lipiodol mixture) was injected until the varices were completely filled. In four patients, the collateral veins seen at balloon-occluded adrenal venography were embolized with coils prior to sclerotherapy. Post-procedural follow-up CT (n=3) or endoscopy (n=8) was performed 1-4 weeks later, and both before and after the procedure, hepatic function was also monitored. Treatment was successful in nine cases: the failure involed rupture of the occlusion balloon during inflation, and a transjugular intrahepatic portosystemic shunt was performed. The cessation of bleeding was confirmed endoscopically or clinically; in three patients, follow-up CT showed complete obliteration of the varices. Hepatic function improved in eight patients, but three weeks after the procedure, one expired due to progressive infiltrative hepatoma. The clinical symptoms of the three patients with hepatic encephalopathy showed remarkable improvement. Although more extensive studies and long-term follow up are needed to overcome the limitations of our study, we believe that BRTO is a technically feasible and clinically effective treatment for gastric varices and hepatic encephalopathy.

  16. Balloon Laryngoplasty for Subglottic Stenosis Caused by Orotracheal Intubation at a Tertiary Care Pediatric Hospital

    Directory of Open Access Journals (Sweden)

    Avelino, Melissa Gomes Ameloti

    2014-01-01

    Full Text Available Introduction In recent years, there has been a reduction in mortality rates in neonatal intensive care units (NICUs due to the impact of modern technological advances in the perinatal field. As a consequence, prolonged orotracheal intubation is used more frequently, and there has been an increase in acquired subglottic stenosis (SGS in children. Subglottic stenosis is a narrowing of the endolarynx and one of the most common causes of stridor and respiratory distress in children. The laryngoplasty balloon has proven effective in dealing with stenosis both as primary and secondary treatments, after open surgery, with the added advantage of being less invasive and not requiring external access. Materials and Methods This study involved children from pediatric intensive care units or NICUs suffering from respiratory distress and who presented an endoscopic diagnosis of Myer and Cotton grade I to III SGS. These patients underwent balloon laryngoplasty with different numbers of interventions depending on the response in each individual case. Results All the patients responded satisfactorily to the balloon laryngoplasty. None required tracheostomy after treatment and all remained asymptomatic even after 6-month follow-up. One patient required just 1 dilation, 4 required 2, 3 underwent the procedure 3 times, and another had 5 dilations. Conclusion The experience presented here is that of balloon laryngoplasty post–orotracheal intubation SGS with very satisfactory results at a tertiary care pediatric hospital. Although the number of patients is limited, our incidence corroborates other studies that demonstrate the efficacy and safety of balloon dilatation in the treatment of SGS.

  17. Endoscopic diagnosis and treatment of biliary obstruction due to acute cholangitis and acute pancreatitis secondary to Fasciola hepatica infection.

    Science.gov (United States)

    Dolay, Kemal; Hasbahçeci, Mustafa; Hatipoğlu, Engin; Ümit Malya, Fatma; Akçakaya, Adem

    2018-01-01

    In the differential diagnosis of biliary obstruction with unknown etiology, biliary fascioliasis should be considered in endemic and nonendemic regions. After diagnostic evaluation, endoscopic retrograde cholangiopancreatography (ERCP) was performed for etiological evaluation and/or treatment of biliary obstruction in five patients with a mean age of 55.8 years. Endoscopic sphincterotomy and cholangiogram revealed linear filling defects in the biliary system. Fasciola hepatica parasites were extracted using balloon and basket catheters in two and three patients, respectively. No morbidity or mortality was observed. F. hepatica infection should be considered as a differential diagnosis of biliary obstruction with unknown etiology in endemic and non-endemic regions. ERCP can be the standard diagnostic and/or therapeutic procedure in cases of biliary obstruction due to fascioliasis. Due to slippery and gel-like characteristics of the parasite, use of a basket catheter in semi-opened position may be required in case of unsuccessful extraction using a balloon catheter.

  18. Endoscopic capacity in West Africa.

    African Journals Online (AJOL)

    patients who received endoscopy, 7 required endoscopic intervention with 6 having gastric or esophageal varices. Currently the ... are living longer3. Chronic GI illnesses, such as non-infec- tious gastric ulcer disease, cancer, dyspepsia and cirrhosis, are on the rise and have created an increased demand for endoscopic ...

  19. Endoscopic transmission of Helicobacter pylori

    NARCIS (Netherlands)

    Tytgat, G. N.

    1995-01-01

    The contamination of endoscopes and biopsy forceps with Helicobacter pylori occurs readily after endoscopic examination of H. pylori-positive patients. Unequivocal proof of iatrogenic transmission of the organism has been provided. Estimates for transmission frequency approximate to 4 per 1000

  20. Robot-assisted endoscopic surgery

    NARCIS (Netherlands)

    Ruurda, J.P.

    2003-01-01

    During the last three years, robot-assisted surgery systems are increasingly being applied in endoscopic surgery. They were introduced with the objective to overcome the challenges of standard endoscopic surgery. With the improvements in manipulation and visualisation that robotic-assistance offers,

  1. Advanced esophageal cancer and esophageal stenosis endoscopic treatment

    International Nuclear Information System (INIS)

    Piazze, A. E mail: apiazze@hc.edu.uy

    2005-01-01

    Advanced esophageal cancer (AEC) is diagnosed during those stages in which surgery is possible, it is palliative for disphagia, with high morbimortality.In inoperable or irresectable cases, resorting to alternative treatment such as radiotherapy or endoscopy may palliate dsphagia.Endoscopically it is possible to place a transtumoral nasogastric catheter (NGC) for preoperative nutrition or branchial therapy (intratumoral iridium).It is possible to dilate the tumor and place and indwelling plastic or auto expandable prosthesis or to inject absolute intratumoral alcohol.There is and evaluation of results and morbimortality of personal case material through the retrospective study of 54 patients in whom 120 procedures such as those referred to above were carried out.The series includes 41 men and 13 women (3-1), 79.5% of which were of ages between 61 and 90.Optic fiber endoscopes or video endoscopes, coaxial dilators, hydro-pneumatic balloons, metallic guides and non industrial and autoexpandable plastic prosthesis were used; 34.1% of procedures were performed under used; 34.1% of procedures were performed under radioscopy.Eleven patient (8 for nutritional purposes and 3 for brachiotherapy)form part of Groups 1 and 2 of NGC.Group 3 consist of:dilations of radicular stenosis with or without neopasic recurrence, or neoplasic infiltration of esophagus, 6 patient; Group 4: 14 patients for the purpose of dilation of esophageal neoplasm; Group 5:prosthesis, 12 patients; Group 6: 11 patients with anastomotic stenosis.In patients in Group 1-2-3 solution was achieved.In Group 3 there was 1 perforation.In Group 4, out of 14 patient 13 were dilated.In Group 5 it proved impossible to place prosthesis in 2 patient, (3.7%).The conclusion arrived at is that various endoscopic techniques may palliate disphagia in patient with AEC, collaborate with preoperative nutrition through enteral path, with brachioterapy or by treating post surgical stenosis, with low mortality

  2. Optimal patient positioning for ligamentotaxis during balloon kyphoplasty of the thoracolumbar and lumbar spine.

    LENUS (Irish Health Repository)

    Cawley, D T

    2011-06-01

    Percutaneous balloon kyphoplasty aims to restore vertebral height, correct angular deformity and stabilize the spine in the setting of vertebral compression fractures. The patient is positioned prone with supports under the iliac crests and upper thorax to allow gravity to extend the spine. In the treatment of lumbar fractures, we evaluated patient positioning with the contribution of hip extension to increase anterior ligamentotaxis, thus facilitating restoration of vertebral height. Our positioning technique created a mean anterior height increase from 72% to 78% of the average height of the cranial and caudal vertebrae (p=0.037). Balloon inflation did not significantly further increase anterior or posterior vertebral height, or Cobb angle.

  3. [Robotic and systems technology for advanced endoscopic procedures].

    Science.gov (United States)

    Arezzo, A; Testa, T; Schurr, M O; Buess, G F; De Gregori, M

    2001-01-01

    The advent of endoscopic techniques changed surgery in many regards. This paper intends to describe an overview about technologies to facilitate endoscopic surgery. The systems described have been developed for the use in general surgery, but an easy application also in other fields of endoscopic surgery seems realistic. The introduction of system technology and robotic technology enables today to design a highly ergonomic solo-surgery platform. This consists of a system of devices for endoscopic surgery (HF, light source, etc...) with which the surgeon interacts directly, positioning systems for optic and instruments that the surgeon drives as the likes without assistance, and a chair to increase the comfort of the surgeon during surgery. The system of endoscopic devices named OREST (Dornier, München) designed already in 1992 opened the way to a number of systems available today that allow to the surgeon a direct control of the instrumentation. A considerable step ahead in endoscopic technology is the introduction of robotic technology to design assisting systems for solo-surgery and microsurgical instrument manipulators. Results of a number of experimental trials on combinations of different positioning devices are presented and commented. A further step in the employment of robotic technology is the design of "master-slave manipulators" to provide the surgeon with additional degrees of freedom of instrumentation. In 1996 a first prototype of an endoscopic manipulator system, named ARTEMIS, designed in cooperation with the Research Center in Karlsruhe, could be used in experimental applications. Clinical use of the system, however, will require further development of the arm mechanics and the control system. The combination with the implementation of telecommunication technology will open new frontiers, such as teleconsulting, teleassistance and telemanipulation.

  4. Endoscopic resection of subepithelial tumors.

    Science.gov (United States)

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel

    2014-12-16

    Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods.

  5. Intragastric balloon in the emergency department: an unusual cause of gastric outlet obstruction.

    Science.gov (United States)

    Khalaf, Natalia I; Rawat, Anish; Buehler, Greg

    2014-04-01

    Obesity has become a worldwide epidemic and is associated with significant morbidity and mortality. Many strategies to promote weight loss, including medications and surgical techniques, have been developed; however, few have proven effective. As the rates of obesity and associated complications continue to climb, there is growing pressure on the medical community to develop less invasive procedures that can provide lasting weight loss results. One surgical treatment for obesity, available in several countries but not yet approved for use in the United States, is the intragastric balloon (IGB). The IGB is a temporary, space-occupying device placed endoscopically into the stomach to decrease gastric volume and provide a sense of early satiety. Our objective is to highlight potential complications of this device that emergency physicians should be familiar with, in particular, gastric outlet obstruction. We report the case of a morbidly obese 63-year-old Middle Eastern man who presented to an emergency department in Texas with mechanical gastric outlet obstruction 2 months after IGB placement. After three endoscopic attempts, the balloon was successfully removed and the obstruction relieved. With an increasingly mobile and obese global population, emergency physicians should be aware of weight loss procedures such as the IGB and appropriate time-sensitive management of high-risk complications. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Wireless capsule endoscopy and double-balloon enteroscopy for the diagnosis of obscure gastrointestinal bleeding.

    Science.gov (United States)

    Gerson, Lauren B; Van Dam, Jacques

    2004-09-01

    Standard endoscopic examination (upper gastrointestinal endoscopy and colonoscopy) fails to detect the cause of gastrointestinal hemorrhage in approximately 5% of patients. Before the availability of wireless capsule endoscopy and double-balloon enteroscopy, imaging modalities for the small intestine distal to the ligament of Treitz included barium contrast examination and/or enteroclysis, push, passive, or intraoperative enteroscopy, technetium 99m labeled sulfur colloid scanning, angiography, and computed tomography, although the diagnostic yield of all of these imaging modalities was low. In 2001, wireless capsule endoscopy became available for the evaluation of patients with probable small intestinal hemorrhage. Advantages of wireless capsule endoscopy include that the procedure is noninvasive, requires no sedation, and does not expose the patient to ionizing radiation. In patients with obscure gastrointestinal hemorrhage, studies have demonstrated an additional 25 to 50% diagnostic yield using wireless capsule endoscopy when compared to other diagnostic modalities. The major limitations of capsule endoscopy were its inability to obtain a biopsy, precisely localize a lesion, or perform therapeutic endoscopy. In 2001, the double-balloon enteroscope was introduced. This new endoscopic technique provides the gastroenterologist with an opportunity for further evaluation and treatment of abnormalities detected on wireless capsule endoscopy or other small intestinal imaging studies.

  7. Endoscopic Findings of Upper Gastrointestinal Involvement in Primary Vasculitis.

    Science.gov (United States)

    Gong, Eun Jeong; Kim, Do Hoon; Chun, Joo Hyun; Ahn, Ji Yong; Choi, Kwi-Sook; Jung, Kee Wook; Lee, Jeong Hoon; Choi, Kee Don; Song, Ho June; Lee, Gin Hyug; Jung, Hwoon-Yong; Kim, Jin Ho; Song, In Hye; Kim, Yong-Gil

    2016-07-15

    Gastrointestinal involvement in vasculitis may result in life-threatening complications. However, its variable clinical presentations and endoscopic features, and the rarity of the disease, often result in delayed diagnosis. Clinical characteristics, endoscopic features, and histopathological findings were reviewed from medical records. Of 6,477 patients with vasculitis, 148 were diagnosed as primary vasculitis with upper gastrointestinal involvement. Of these, 21 cases (14.2%) were classified as large-vessel vasculitis, 17 cases (11.5%) as medium-vessel vasculitis, and 110 cases (74.3%) as small-vessel vasculitis. According to the specific diagnosis, IgA vasculitis (Henoch-Schönlein purpura) was the most common diagnosis (56.8%), followed by Takayasu arteritis (14.1%), microscopic polyangiitis (10.1%), and polyarteritis nodosa (6.8%). Gastrointestinal symptoms were present in 113 subjects (76.4%), with abdominal pain (78.8%) the most common symptom. Erosion and ulcers were striking endoscopic features, and the second portion of the duodenum was the most frequently involved site. Biopsy specimens were obtained from 124 patients, and only eight (5.4%) presented histopathological signs of vasculitis. Diagnosis of vasculitis involving the upper gastrointestinal tract is difficult. Because of the widespread use of endoscopy, combining clinical features with endoscopic findings may facilitate making appropriate diagnoses; however, the diagnostic yield of endoscopic biopsy is low.

  8. Late complications of percutaneous tracheostomy using the balloon dilation technique.

    Science.gov (United States)

    Araujo, J B; Añón, J M; García de Lorenzo, A; García-Fernandez, A M; Esparcia, M; Adán, J; Relanzon, S; Quiles, D; de Paz, V; Molina, A

    2018-04-01

    The purpose of this study was to determine the late complications in critically ill patients requiring percutaneous tracheostomy (PT) using the balloon dilation technique. A prospective, observational cohort study was carried out. Two medical-surgical intensive care units (ICU). All mechanically ventilated adult patients consecutively admitted to the ICU with an indication of tracheostomy. All patients underwent PT according to the Ciaglia Blue Dolphin ® method, with endoscopic guidance. Survivors were interviewed and evaluated by fiberoptic laryngotracheoscopy and tracheal computed tomography at least 6 months after decannulation. Intraoperative, postoperative and long-term complications and mortality (in-ICU, in-hospital) were recorded. A total of 114 patients were included. The most frequent perioperative complication was minor bleeding (n=20) and difficult cannula insertion (n=19). Two patients had severe perioperative complications (1.7%) (major bleeding and inability to complete de procedure in one case and false passage and desaturation in the other). All survivors (n=52) were evaluated 211±28 days after decannulation. None of the patients had symptoms. Fiberoptic laryngotracheoscopy and computed tomography showed severe tracheal stenosis (>50%) in 2patients (3.7%), both with a cannulation period of over 100 days. Percutaneous tracheostomy using the Ciaglia Blue Dolphin ® technique with an endoscopic guide is a safe procedure. Severe tracheal stenosis is a late complication which although infrequent, must be taken into account due to its lack of clinical expressiveness. Evaluation should be considered in those tracheostomized critical patients who have been cannulated for a long time. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  9. Trajectory Control For High Altitude Balloons

    Science.gov (United States)

    Aaron, K.; Nock, K.; Heun, M.; Wyszkowski, C.

    We will discuss the continuing development of the StratoSailTM Balloon Trajectory Control System presented at the 33rd COSPAR in 2000. A vertical wing suspended on a 15-km tether from a high altitude balloon uses the difference in wind velocity between the altitude of the balloon and the altitude of the wing to create an aerodynamic sideforce. This sideforce, transmitted to the balloon gondola via the tether, causes the balloon to move laterally. Although the balloon's resultant drift velocity is quite small (a few meters per second), the effect becomes significant over long periods of time (hours to days). Recently, a full-scale wing, rudder and boom assembly has been fabricated, a winch system testbed has been completed, and a lightweight tether with reduced susceptibility to ultraviolet damage has been developed. The development effort for this invention, with pending international patents, has been funded by the NASA/SBIR program in support of the Ultra Long Duration Balloon (ULDB) program.

  10. 14 CFR 61.115 - Balloon rating: Limitations.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Balloon rating: Limitations. 61.115 Section... rating: Limitations. (a) If a person who applies for a private pilot certificate with a balloon rating... operate a gas balloon. (b) If a person who applies for a private pilot certificate with a balloon rating...

  11. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  12. Abdominal cavity balloon for preventing a patient's bleeding

    NARCIS (Netherlands)

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po

  13. High-quality endoscope reprocessing decreases endoscope contamination.

    Science.gov (United States)

    Decristoforo, P; Kaltseis, J; Fritz, A; Edlinger, M; Posch, W; Wilflingseder, D; Lass-Flörl, C; Orth-Höller, D

    2018-02-24

    Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes, have been described. The rate of microbial endoscope contamination varies dramatically in literature. The aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture-based and molecular-based analyses. The contamination rate of GI endoscopes was 1.3%-4.6% according to the national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene-relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples failing in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly Pseudomonas oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n = 9, 17.6%) mainly due to technical faults, phase II revealed lapses (n = 6, 11.5%) only on account of microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  15. A comparative study of internally and externally capped balloons using small scale test balloons

    Science.gov (United States)

    Bell, Douglas P.

    1994-01-01

    Caps have been used to structurally reinforce scientific research balloons since the late 1950's. The scientific research balloons used by the National Aeronautics and Space Administration (NASA) use internal caps. A NASA cap placement specification does not exist since no empirical information exisits concerning cap placement. To develop a cap placement specification, NASA has completed two in-hangar inflation tests comparing the structural contributions of internal caps and external caps. The tests used small scale test balloons designed to develop the highest possible stresses within the constraints of the hangar and balloon materials. An externally capped test balloon and an internally capped test balloon were designed, built, inflated and simulated to determine the structural contributions and benefits of each. The results of the tests and simulations are presented.

  16. Microscopic polyangiitis complicated with ileal involvement detected by double-balloon endoscopy: a case report.

    Science.gov (United States)

    Fukushima, Masashi; Inoue, Satoko; Ono, Yuichiro; Tamaki, Yoshitaka; Yoshimura, Hajime; Imai, Yukihiro; Inokuma, Tetsuro

    2013-03-02

    Microscopic polyangiitis is characterized by pauci-immune, necrotizing small-vessel vasculitis and an anti-neutrophil cytoplasmic antibody-associated vasculitis. Although gastrointestinal involvement in microscopic polyangiitis is not rare, endoscopic observation of it is extremely rare. To the best of our knowledge, this is the first case report of small intestinal involvement in microscopic polyangiitis detected and followed up by double-balloon endoscopy. A 70-year-old Japanese woman was transferred to our hospital for close examination of suspected small intestinal lymphoma. Retrograde double-balloon endoscopy revealed various forms of ulcers with redness and edema in the ileum. Histological findings suggested ischemic changes. Because mononeuritis multiplex and a fever spike appeared later, vasculitis was suspected. The perinuclear anti-neutrophil cytoplasmic antibody titer was elevated. Nerve biopsy results suggested vasculitis. From these findings, microscopic polyangiitis was diagnosed. It was suggested that microscopic polyangiitis caused the intestinal involvement. Intravenous pulse cyclophosphamide and oral predonisolone were started. After treatment, perinuclear anti-neutrophil cytoplasmic antibodies decreased to the normal range. Retrograde double-balloon endoscopy after treatment showed ulcer scars and no ulcer. The cause of gastrointestinal involvement in microscopic polyangiitis is ischemia due to vasculitis. It is difficult to diagnose small-vessel vasculitis by endoscopic biopsy. Although histological evidence of microscopic polyangiitis is important, the treatment should not be delayed by repeating the biopsy, because such delay can result in adverse sequela.This case report shows that microscopic polyangiitis should be considered as a differential diagnosis when small intestinal changes like those in the present case are observed by endoscopy.

  17. Double-scope per oral endoscopic myotomy (POEM): a prospective randomized controlled trial.

    Science.gov (United States)

    Grimes, Kevin L; Inoue, Haruhiro; Onimaru, Manabu; Ikeda, Haruo; Tansawet, Amarit; Bechara, Robert; Tanaka, Shinwa

    2016-04-01

    Since its introduction in 2010, per oral endoscopic myotomy (POEM) has offered an alternative to laparoscopic Heller myotomy for the treatment of achalasia. A gastric myotomy length of 3 cm has been recommended; however, it can be difficult to ensure that adequate submucosal dissection has been performed during the procedure. Commonly accepted endoscopic markers of the gastric side can be inaccurate, particularly in patients with prior endoscopic treatments, such as balloon dilation or Botox injection of the lower esophageal sphincter. We hypothesized that the use of a second endoscope would result in a more complete gastric myotomy. One hundred consecutive achalasia patients were randomized into single- and double-scope POEM groups. In the treatment group, a second endoscope was used to obtain a retroflexed view of the gastric cardia, while the dissecting scope transilluminated from the end of the submucosal tunnel. Prospectively collected data were analyzed, including myotomy lengths, procedure times, adverse events, and clinical outcomes. POEM was completed with high rates of technical (98-100%) and clinical success (93-97%) in both groups, with a low rate of serious adverse events (2%). The second endoscope resulted in a 17 min increase in procedure time (94 vs. 77 min), myotomy extension in 34% of cases, and an increase in the average gastric myotomy length from 2.6 to 3.2 cm (p = 0.01). A second endoscope is useful for ensuring a complete gastric myotomy during POEM. With minimal increase in procedure time and no increase in morbidity, it may be particularly useful in cases of sigmoid esophagus or otherwise altered anatomy that makes identification of the gastroesophageal junction difficult.

  18. Endoscopic transpapillary stenting or conservative treatment for pancreatic fistulas in necrotizing pancreatitis: multicenter series and literature review

    NARCIS (Netherlands)

    Bakker, O.J.; Baal, M.C. van; Santvoort, H.C. van; Besselink, M.G.; Poley, J.W.; Heisterkamp, J.; Bollen, T.L.; Gooszen, H.G.; Eijck, C.H. van

    2011-01-01

    OBJECTIVE: Endoscopic transpapillary stenting (ETS) of the pancreatic duct facilitates ductal outflow and may reduce time to pancreatic fistula closure. However, data on the feasibility of ETS in patients with necrotizing pancreatitis are scarce. BACKGROUND: Pancreatic fistulas often occur after

  19. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    Science.gov (United States)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  20. Balloon dilatation in patients with gastric outlet obstruction related to peptic ulcer disease.

    Science.gov (United States)

    Hamzaoui, Lamine; Bouassida, Mahdi; Ben Mansour, Imed; Medhioub, Mouna; Ezzine, Heykal; Touinsi, Hassen; Azouz, Mohamed M

    2015-01-01

    Gastric outlet obstruction (GOO) is a rare complication of peptic ulcer disease (PUD). The endoscopic balloon dilatation (EBD) associated with medical treatment of Helicobacter pylori is a successful method in the management of pyloric stenosis. The aim of this study was to describe epidemiological, clinical, and endoscopic characteristics of GOO related to PUD and to evaluate the effectiveness, safety, and outcome of EBD. In a retrospective study of patients seen between 1999 and 2009 with symptoms of GOO secondary to PUD, pyloro-bulbar stenosis was confirmed by endoscopic examination. Balloon dilatation was performed when obstruction persisted after treatment with double-dose proton-pump inhibitor (PPI) intravenously for 7-10days. The H. pylori status was assessed with histology, and eradication therapy was prescribed for infection. A total of 45 consecutive patients (38 males, 7 females median age, 51.9years; range, 20-58years) with symptoms of GOO secondary to PUD underwent EBD. Median follow-up time of the 45 patients was 32months (range, 4-126months). The immediate success rate of the procedure was 95.5%. Clinical remission was noted in 84.4% of the patients. Remission without relapse was observed in 55.8%, 30months after the dilatation. Pyloric stenosis relapsed in 15 patients (39.5%) after a median period of 22.9months. The dilatation was complicated in three patients (6.7%, two perforations and one bleeding). A total of 13 patients (29%) underwent surgery. H. pylori was found to be positive in 97.7% of the patients, and was eradicated in 78.4% of them. Smoking and failure of H. pylori eradication were associated with the relapse of the stenosis. EBD is a simple, effective, and safe therapy for the GOO related to PUD, producing short- and long-term remission. Copyright © 2015 Arab Journal of Gastroenterology. Published by Elsevier B.V. All rights reserved.

  1. Hepatic applications of endoscopic ultrasound

    DEFF Research Database (Denmark)

    Srinivasan, Indu; Tang, Shou-Jiang; Vilmann, Andreas S

    2015-01-01

    The diagnosis and staging of various gastrointestinal malignancies have been made possible with the use of endoscopic ultrasound, which is a relatively safe procedure. The field of endoscopic ultrasound is fast expanding due to advancements in therapeutic endoscopic ultrasound. Though various...... studies have established its role in gastrointestinal malignancies and pancreatic conditions, its potential in the field of hepatic lesions still remains vastly untapped. In this paper the authors attempt to review important and landmark trials, case series and case studies involving hepatic applications...

  2. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  3. Magnetometer for Balloons and UAVs Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR project will investigate a new, low-cost approach to atomic magnetometry that is suited for operation from UAVs and research balloons. Atomic...

  4. Solid State Inflation Balloon Active Deorbiter

    Data.gov (United States)

    National Aeronautics and Space Administration — The Solid State Inflation Balloon (SSIB) is a simple, reliable, low-cost, non-propulsive system for deliberate deorbit and control of downrange point-of-impact that...

  5. Shielded Mars Balloon Launcher (SMBL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences, along with its partner Vertigo Industries, proposes a novel approach to deployment of balloon-based payloads into the Martian atmosphere....

  6. Evaluation of the Distribution of Paclitaxel After Application of a Paclitaxel-Coated Balloon in the Rabbit Urethra.

    Science.gov (United States)

    Barbalias, Dimitrios; Lappas, Georgios; Ravazoula, Panagiotia; Liourdi, Despoina; Kyriazis, Iason; Liatsikos, Evangelos; Kallidonis, Panagiotis

    2018-03-02

    Urethral strictures are a common urologic problem that could require complex reconstructive procedures. Urethral dilatation represents a frequent practiced intervention associated with high recurrence rates. Drug-coated percutaneous angioplasty balloons (DCBs) with cytostatic drugs have been effectively used for the prevention of vascular restenosis after balloon dilatation. To reduce restenosis rates of urethral dilatation, these balloons could be used in the urethra. Nevertheless, the urothelium is different than the endothelium and these drugs may not be distributed to the outer layers of the urethra. Thus, an experiment was performed to evaluate the distribution of paclitaxel (PTX) in the rabbit urethra after the inflation of a PTX-coated balloon (PCB). Eleven rabbits underwent dilatation of the posterior urethra with common endoscopic balloons after urethrography. Nine of these rabbits were additionally treated with PCB. The urethras of the two control animals were removed along with three more dilated with PCB urethras immediately after the dilatation. The remaining of the urethras were removed after 24 (n = 3) and 48 hours (n = 3). The posterior segments of the urethras were evaluated with hematoxylin and eosin staining as well as with immunohistochemistry with polyclonal anti-PTX antibody. The two control specimens showed denudation of the urothelium after balloon dilatations and no PTX was observed. All specimens from dilated PCB urethras showed distribution of PTX to all layers of the urethra. The specimens that were immediately removed exhibited denudation of the urothelium without any inflammation. The specimens removed at 24 and 48 hours showed mild acute inflammation. PTX was distributed to the urothelial, submucosal, and smooth muscle layers of the normal rabbit urethra immediately after dilatation with a DCB. PTX and mild inflammation were present at the site 24 and 48 hours after the dilatation.

  7. Test ventilation with smoke, bubbles, and balloons

    International Nuclear Information System (INIS)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs

  8. Significance of balloon pressure recording during angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zollikofer, C.L.; Salomonowitz, E.; Frick, M.P.; Castaneda-Zuniga, W.R.; Amplatz, K.; Bruehlmann, W.F.

    1985-05-01

    During angioplasty of artificial stenoses, atherosclerotic human cadaver arteries, and normal canine arteries, pressure and volume of the dilatation balloons were continuously recorded. We found that a sudden yield of a lesion corresponded to a sudden drop in the pressure curve and an increase of the balloon volume. Volume monitoring was insensitive, but pressure recording was very precise. Continuous pressure recording, using a non-compliant inflation system, correctly demonstrated small breaks and ruptures of atherosclerotic vessels, changes not seen on fluoroscopy.

  9. Endoscopic retrograde cholanglopancreatography

    International Nuclear Information System (INIS)

    Horii, S.C.; Garra, B.S.; Zeman, R.K.; Krasner, B.H.; Lo, S.C.B.; Davros, W.J.; Silverman, P.M.; Cattau, E.L.; Fleischer, D.E.; Benjamin, S.B.S.B.

    1989-01-01

    As part of the clinical evaluation of image management and communications system (IMACS), the authors undertook a prospective study to compare conventional film versus digitized film viewed on a workstation. Twenty-five each of normal and abnormal endoscopic retrograde cholangiopancreatographic (ERCP) studies were digitized with a 1,684 x 2,048-pixel matrix and evaluated in a single-blind fashion on the workstation. The resulting interpretations were then compared with those resulting from interpretation of film (spot film and 100-mm photospot) images. They report that no significant differences were found in ability to see anatomic detail or pathology. A second study involved performing 10 ERCP studies in a lithotripsy suite equipped with biplane digital fluoroscopy. The digital video displays were comparable in quality to that of film. Progress is being made in using the IMACS for archiving and retrieval of all current ERCP images

  10. Revision endoscopic sinonasal surgery.

    Science.gov (United States)

    Cantillano, Pablo; Rubio, Fabián; Naser, Alfredo; Nazar, Rodolfo

    Endoscopic sinonasal surgery is the procedure of choice in the treatment of chronic rhinosinusitis and sinonasal polyposis refractory to medical treatment, with high rates of success (76% to 97.5%). However, 2.5%-24% of those patients will require revision surgery (RESS). In this study, we present the clinical, anatomical, radiological and histological features of patients receiving RESS in our centre during a 3-year period. A retrospective review of clinical, anatomical, radiological and histopathological data of patients receiving revision endoscopic sinonasal surgery between 2012 and 2014 was carried out. From 299 surgery procedures performed, 27 (9%) were revision surgeries. The mean patient age was 46 years, with a male/female ratio of 1.4/1. The most frequent preoperative and postoperative diagnosis was chronic polypoid rhinosinusitis. The mean time since the previous surgery was 6.1 years, with 11.9 months of mean follow-up since that surgery. Stenotic antrostomy was found during revision in 81.5% of the patients and incomplete anterior ethmoidectomy and persistent uncinate process, in 59.3%. In radiology, 70.4% of patients had persistent anterior ethmoidal cells. Antrostomy or widening of antrostomy was performed in 96.3% of cases and anterior ethmoidectomy or completion of it was performed in 66.7%. Polyps, stenotic antrostomy and incomplete ethmoidectomy were the most frequent causes of revision surgery, in concordance with the procedures performed. The patients had long periods of time without follow-up between surgeries. Further investigation is necessary to generate measures to reduce the number of revision surgeries. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  11. Usefulness of Double-Balloon Endoscopy in the Postoperative Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    Masaki Endo

    2011-01-01

    Full Text Available Background. The small intestine has been considered to be a highly difficult organ to visualize in imaging examinations due to its anatomical location compared with the stomach and the colon. In recent years, many imaging modalities have become available, such as CT enterography, MR enterography, capsule endoscopy (CE, and double-balloon endoscopy (DBE. Patients and Methods. DBE was performed in the postoperative intestines of 91 patients (128 DBE examinations at Iwate Medical University between 2004 and 2010. There were 61 male and 30 female patients, and their mean age was 69.7 years (range: 30–80 years. Results. A total of 124 DBE examinations were performed with endoscope insertion into the reconstructed intestines. The endoscope reached the blind end in 115 of 124 examinations, (92.7%. There were 17 patients with obscure gastrointestinal bleeding in whom 30 DBE examinations were performed. The bleeding site was identified in 12 patients (70.6%. Nine patients underwent endoscopic treatment. Hemostasis was achieved in all patients. Conclusion. DBE is very useful modality for the assessment and application of endotherapy to areas of the small bowel which have been altered by surgery.

  12. Endoscopic ultrasound and pancreas divisum

    DEFF Research Database (Denmark)

    Rana, Surinder S; Gonen, Can; Vilmann, Peter

    2012-01-01

    cholangiopancreatography is the gold standard for its diagnosis, but is invasive and associated with significant adverse effects. Endoscopic ultrasound (EUS) allows the detailed evaluation of the pancreaticobiliary ductal system without injecting contrast in these ducts. Moreover, it provides detailed images...

  13. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  14. Transcrestal sinus lift and implant placement using the sinus balloon technique

    Science.gov (United States)

    Galán-Gil, Sónnica; Carrillo-García, Celia; Peñarrocha-Diago, David; Peñarrocha-Diago, Miguel

    2012-01-01

    Objective: A description is made of transcrestal sinus lift using the sinus balloon technique, evaluating the bone height achieved and implant success one year after prosthetic loading. Material and method: Between January and July 2007, transcrestal sinus lift using the sinus balloon technique for dental implant placement was carried out in 6 patients. A panoramic X-ray study and maxillary computed tomography scan were carried out before the operation, in order to discard possible sinus pathology. During the intervention, the integrity of the sinus membrane was evaluated using a Medi Pack Pal endoscope (Farol Store and Co., Tuttlingen, Germany), and the intraoperative complications were analyzed. The dental implants were placed in the same surgical step in the presence of 3 mm or more of residual bone. Following the operation, panoramic X-rays were used to assess the bone height gained. One year after prosthetic loading, the implant success rate was determined based on the criteria of Buser. Results: One patient was excluded due to Schneider’s membrane perforation as confirmed by endoscopy. Trans-crestal sinus lift was carried out in 5 males with a mean age of 41.6 years (range 27-51), without antecedents of sinus disease. There were no intraoperative complications. In four patients the implants were placed simultaneous to sinus lift, while in another case implant placement was postponed due to insufficient remaining bone height. The mean gain in height after the operation was 8.7 mm. One year after prosthetic loading, the implant success rate was 100%. Conclusions: Transcrestal sinus lift using the sinus balloon technique is a minimally invasive procedure. In 5 patients the bone height gained proved sufficient to allow implant placement even in the presence of 3 mm of residual bone. Key words: Sinus lift, balloon, sinus complications. PMID:22157670

  15. [Coronary angioplasty using double balloon in artery of large calibre (hugging balloons)].

    Science.gov (United States)

    Centemero, M P; Cano, M N; Maldonado, G; de Almeida, J D; Sousa, A G; Sousa, J E

    1993-07-01

    In this case report the transluminal coronary angioplasty was performed in a oversized right coronary artery with a severe lesion with thrombus inside, using the Hugging balloon technique (two dilatation balloon catheters used simultaneously). This technique achieved minimal residual lesion and had a favorable clinical outcome of the patient.

  16. Hemosuccus Pancreaticus in the Era of Capsule Endoscopy and Double Balloon Enteroscopy Complicated by Multifocal Mycobacterium chelonae/abscessus Infection

    Directory of Open Access Journals (Sweden)

    Shabana F. Pasha

    2007-08-01

    Full Text Available Hemosuccus pancreaticus is a rare etiology of obscure gastrointestinal bleeding characterized by bleeding into the pancreatic duct. The diagnosis may be delayed for months to years, due to the episodic nature of bleeding and failure to consider the diagnosis. Patients often undergo multiple endoscopies and radiologic evaluations prior to diagnosis. Incidental gastrointestinal findings may lead to unnecessary endoscopic and surgical interventions. This report describes a patient with hemosuccus pancreaticus diagnosed in the era of video capsule endoscopy and double balloon enteroscopy, whose management was complicated by multifocal Mycobacteria chelonae/abscessus infection.

  17. Endoscopic vs. tactile evaluation of subgingival calculus.

    Science.gov (United States)

    Osborn, Joy B; Lenton, Patricia A; Lunos, Scott A; Blue, Christine M

    2014-08-01

    Endoscopic technology has been developed to facilitate imagery for use during diagnostic and therapeutic phases of periodontal care. The purpose of this study was to compare the level of subgingival calculus detection using a periodontal endoscope with that of conventional tactile explorer in periodontitis subjects. A convenience sample of 26 subjects with moderate periodontitis in at least 2 quadrants was recruited from the University of Minnesota School of Dentistry to undergo quadrant scaling and root planing. One quadrant from each subject was randomized for tactile calculus detection alone and the other quadrant for tactile detection plus the Perioscope ™ (Perioscopy Inc., Oakland, Cali). A calculus index on a 0 to 3 score was performed at baseline and at 2 post-scaling and root planing visits. Sites where calculus was detected at visit 1 were retreated. T-tests were used to determine within-subject differences between Perioscope™ and tactile measures, and changes in measures between visits. Significantly more calculus was detected using the Perioscope™ vs. tactile explorer for all 3 subject visits (pcalculus detection from baseline to visit 1 were statistically significant for both the Perioscope™ and tactile quadrants (pcalculus detection from visit 1 to visit 2 was only significant for the Perioscope™ quadrant (pcalculus at this visit. It was concluded that the addition of a visual component to calculus detection via the Perioscope™ was most helpful in the re-evaluation phase of periodontal therapy. Copyright © 2014 The American Dental Hygienists’ Association.

  18. Identifying DNA Methylation Biomarkers for Non-Endoscopic Detection of Barrett’s Esophagus

    Science.gov (United States)

    Moinova, Helen R.; LaFramboise, Thomas; Lutterbaugh, James D.; Chandar, Apoorva Krishna; Dumot, John; Faulx, Ashley; Brock, Wendy; De la Cruz Cabrera, Omar; Guda, Kishore; Barnholtz-Sloan, Jill S.; Iyer, Prasad G.; Canto, Marcia I.; Wang, Jean S.; Shaheen, Nicholas J.; Thota, Prashanti N.; Willis, Joseph E.; Chak, Amitabh; Markowitz, Sanford D.

    2018-01-01

    We report a biomarker-based non-endoscopic method for detecting Barrett’s esophagus (BE), based on detecting methylated DNAs retrieved via a swallowable balloon-based esophageal sampling device. BE is the precursor of, and a major recognized risk factor for, developing esophageal adenocarcinoma (EAC). Endoscopy, the current standard for BE detection, is not cost-effective for population screening. We performed genome-wide screening to ascertain regions targeted for recurrent aberrant cytosine methylation in BE, identifying high-frequency methylation within the CCNA1 locus. We tested CCNA1 DNA methylation as a BE biomarker in cytology brushings of the distal esophagus from 173 individuals with or without BE. CCNA1 DNA methylation demonstrated an area under the curve (AUC)=0.95 for discriminating BE-related metaplasia and neoplasia cases versus normal individuals, performing identically to methylation of VIM DNA, an established BE biomarker. When combined, the resulting two biomarker panel was 95% sensitive and 91% specific. These results were replicated in an independent validation cohort of 149 individuals, who were assayed using the same cutoff values for test positivity established in the training population. To progress toward non-endoscopic esophageal screening, we engineered a well-tolerated, swallowable, encapsulated balloon device able to selectively sample the distal esophagus within 5 minutes. In balloon samples from 86 individuals, tests of CCNA1 plus VIM DNA methylation detected BE metaplasia with 90.3% sensitivity and 91.7% specificity. Combining the balloon sampling device with molecular assays of CCNA1 plus VIM DNA methylation enables an efficient, well-tolerated, sensitive, and specific method of screening at-risk populations for BE. PMID:29343623

  19. High efficacy with deep nurse-administered propofol sedation for advanced gastroenterologic endoscopic procedures

    DEFF Research Database (Denmark)

    Jensen, Jeppe Thue; Hornslet, Pernille; Konge, Lars

    2016-01-01

    BACKGROUND AND STUDY AIMS: Whereas data on moderate nurse-administered propofol sedation (NAPS) efficacy and safety for standard endoscopy is abundant, few reports on the use of deep sedation by endoscopy nurses during advanced endoscopy, such as Endoscopic Retrograde Cholangiopancreatography (ERCP......) and Endoscopic Ultrasound (EUS) are available and potential benefits or hazards remain unclear. The aims of this study were to investigate the efficacy of intermittent deep sedation with propofol for a large cohort of advanced endoscopies and to provide data on the safety. PATIENTS AND METHODS: All available...... data from patients sedated with intermittent deep NAPS for ERCP, EUS or double balloon enteroscopy (DBE, since the method was implemented in May 2007 through December 2012 were included for evaluation in a retrospective case-control design. RESULTS: Data from 1899 patients undergoing 1899 procedures...

  20. Side effects of endoscopic variceal ligation by using Indonesian Endoscopic Ligator versus Endoscopic Variceal Sclerotherapy.

    Science.gov (United States)

    Simadibrata, Marcellus; Syam, Ari F; Fauzi, Achmad; Abdullah, Murdani; Rani, Abdul A

    2011-01-01

    to investigate the side effects and survival of endoscopic variceal ligation by using Indonesian Endoscopic Ligator versus Endoscopic Variceal Sclerotherapy. we studied the medical records and endoscopy reports of patients who underwent endoscopic variceal ligation (EVL) or endoscopic sclerotherapy (EST) from January 2003 until December 2006. EST was done using ethoxysclerol injection; and ligation was done using a home-made Indonesian endoscopic ligating device. Patient characteristics, side effects of EVL and EST, as well as survival and length of stay were collected. Data of side effects was analyzed by chi-square test. there were no statistically significant differences of patients characteristics among both groups. The side effects in EVL group (29.2%) were less frequent than the EST group (60.9%) (p = 0.009). The death side effect in the EVL group (1.0%) was less frequent than in the EST group (21.7%) (pEVL and EST were 91.7% and 16.7%, respectively (pEVL had fewer side effects than EST in the treatment of esophageal varices bleeding. Death in the EVL group was lower than in the EST group.

  1. The last innovation in achalasia treatment; per-oral endoscopic myotomy.

    Science.gov (United States)

    Aslan, Fatih; Akpınar, Zehra; Alper, Emrah; Atay, Aynur; Yurtlu, Derya Aslan; Çekiç, Cem; Bor, Serhat; Ünsal, Belkis

    2015-05-01

    Per-oral endoscopic myotomy (POEM) is a minimally invasive endoscopic treatment option for patients with achalasia and has been performed since 2010. It is less invasive than Heller myotomy and its use is spreading rapidly worldwide. We present our results of POEM that, to the best of our knowledge, are the first cases in Turkey. We enrolled patients between May 2014 and September 2014; 8 patients with achalasia whose complaints recurred after pneumatic balloon dilatation underwent POEM. The procedure was performed under general anesthesia at the endoscopy unit of the gastroenterology clinic. Demographic data was recorded before the procedure, and the results of the procedure were recorded prospectively. The median age of the patients was 42.5 (30-72) years. Preoperative and postoperative median Eckardt scores were 10 (8-12) and 1 (0-2), respectively. The median total duration of the procedure was 101 (71-158) min, and the median myotomy length was 13.5 (10-16) cm. Postoperative oral intake started on median day 1 (1-2) and the length of hospital stay was 4 (3-6) days. In 2 patients, capnoperitoneum developed during the procedure and was treated with a Veress needle. POEM is a safe endoscopic treatment modality for patients with achalasia in centers that are experienced in advanced endoscopic techniques.

  2. Antibiotic prophylaxis for patients undergoing elective endoscopic ...

    African Journals Online (AJOL)

    Antibiotic prophylaxis for patients undergoing elective endoscopic retrograde cholangiopancreatography. M Brand, D Bisoz. Abstract. Background. Antibiotic prophylaxis for endoscopic retrograde cholangiopancreatography (ERCP) is controversial. We set out to assess the current antibiotic prescribing practice among ...

  3. Endoscopic Transaxillary Near Total Thyroidectomy

    Science.gov (United States)

    Ejeh, Ijeoma Acholonu; Speights, Fredne; Rashid, Qammar N.; Ideis, Mustafa

    2006-01-01

    Background: Since first reported in 1996, endoscopic minimally invasive surgery of the cervical region has been shown to be safe and effective in the treatment of benign thyroid and parathyroid disease. The endoscopic transaxillary technique uses a remote lateral approach to the thyroid gland. Because of the perceived difficulty in accessing the contralateral anatomy of the thyroid gland, this technique has typically been reserved for patients with unilateral disease. Objectives: The present study examines the safety and feasibility of the transaxillary technique in dissecting and assessment of both thyroid lobes in performing near total thyroidectomy. Methods: Prior to this study we successfully performed endoscopic transaxillary thyroid lobectomy in 32 patients between August 2003 and August 2005. Technical feasibility in performing total thyroidectomy using this approach was accomplished first utilizing a porcine model followed by three human cadaver models prior to proceeding to human surgery. After IRB approval three female patients with histories of enlarging multinodular goiter were selected to undergo endoscopic near total thyroidectomy. Results: The average operative time for all models was 142 minutes (range 57–327 min). The three patients in this study had clinically enlarging multinodular goiters with an average size of 4 cm. The contralateral recurrent laryngeal nerve and parathyroid glands were identified in all cases. There was no post-operative bleeding, hoarseness or subcutaneous emphysema. Conclusion: Endoscopic transaxillary near total thyroidectomy is feasible and can be performed safely in human patients with bilateral thyroid disease. PMID:16882421

  4. [Endoscopic full-thickness resection].

    Science.gov (United States)

    Meier, B; Schmidt, A; Caca, K

    2016-08-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.

  5. Endoscopic corpus callosotomy and hemispherotomy.

    Science.gov (United States)

    Sood, Sandeep; Marupudi, Neena I; Asano, Eishi; Haridas, Abilash; Ham, Steven D

    2015-12-01

    Corpus callosotomy and hemispherotomy are conventionally performed via a large craniotomy with the aid of a microscope for children with intractable epilepsy. Primary technical considerations include completeness of disconnection and blood loss. The authors describe an endoscopic technique performed through a microcraniotomy for these procedures. Four patients with drop attacks and 2 with intractable seizures related to a neonatal stroke underwent endoscopic complete corpus callosotomy and hemispherotomy, respectively. The surgeries were performed through a 2- to 3-cm precoronal microcraniotomy. Interhemispheric dissection to the corpus callosum was done using the standard technique. Subsequently, the bimanual technique with a suction device mounted on an endoscope was used to perform a complete corpus callosotomy, including interforniceal and anterior commissure disconnection. In patients who had hemispherotomy, the fornix was resected posteriorly and lateral disconnection was done by unroofing the temporal horn. Anteriorly, endoscopic corticectomy was done along the ipsilateral anterior cerebral artery to reach the bifurcation of the internal carotid artery to complete the anterior disconnection. Postoperative MRI and diffusion tensor imaging (DTI) of the brain were performed to confirm complete disconnection. The procedure was accomplished successfully in all patients, with excellent visualization secured. None of the patients required a blood transfusion. Postoperative MRI and DTI confirmed completeness of the disconnection. Patients who underwent corpus callosotomy had complete resolution of drop attacks at a mean follow-up of 6 months, and patients who underwent hemispherotomy became seizure free. Endoscopic corpus callosotomy and hemispherotomy are surgically feasible procedures associated with minimal blood loss, minimal risk, and excellent visualization.

  6. Facilitating innovations

    NARCIS (Netherlands)

    Buurma, J.S.; Visser, A.J.; Migchels, G.

    2011-01-01

    Many innovations involve changes which transcend the individual business or are only achievable when various businesses and/or interested parties take up the challenge together. In System Innovation Programmes, the necessary innovations are facilitated by means of workshops related to specific areas

  7. Advanced Onboard Energy Storage Solution for Balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced Balloon Programs at NASA are looking for a potential 100 day missions at mid-altitudes. These balloons would be powered by solar panels to take advantage of...

  8. Crash in Australian outback ends NASA ballooning season

    Science.gov (United States)

    Harris, Margaret

    2010-06-01

    NASA has temporarily suspended all its scientific balloon launches after the balloon-borne Nuclear Compton Tele scope (NCT) crashed during take-off, scattering a trail of debris across the remote launch site and overturning a nearby parked car.

  9. Spectrum of ballooning instabilities in a stellarator

    International Nuclear Information System (INIS)

    Cooper, W.A.; Singleton, D.B.; Dewar, R.L.

    1995-08-01

    The recent revival of interest in the application of the 'ballooning formalism' to low-frequency plasma instabilities has prompted a comparison of the Wentzel-Brillouin-Kramers (WKB) ballooning approximation with an (in principle) exact normal mode calculation for a three-dimensional plasma equilibrium. Semiclassical quantization, using the ideal magnetohydrodynamic (MHD) ballooning eigenvalue to provide a local dispersion relation, is applied to a ten-field period stellarator test case. Excellent qualitative agreement, and good quantitative agreement is found with predictions from the TERPSICHORE code for toroidal mode numbers from 1 to 14 and radial mode numbers from 0 to 2. The continuum bands predicted from three-dimensional WKB theory are too narrow to resolve. (author) 3 figs., 24 refs

  10. [Intraaortic balloon pumping( IABP) in Japan].

    Science.gov (United States)

    Ono, Tomoyuki; Tanoue, Yoshihisa; Tominaga, Ryuji

    2014-07-01

    The intraaortic balloon pumping (IABP) is the most widely used circulatory assist device. IABP increases coronary perfusion in diastolic phase by the inflation of the balloon in the descending aorta (diastolic augmentation) and reduces afterload in systolic phase by the deflation of the balloon( systolic unloading). IABP improves the hemodynamic condition of patients who fall into acute heart failure and/or cardiogenic shock. Six-type IABP system can be used in Japan. The IABP-SHOCK II trial shows that there is no significant difference in mortality between optimal medical treatment with IABP and without IABP in addition to early revascularization. Clinical backgrounds in Japan are different from those in IABP-SHOCK II trial, and the further prospective studies of IABP in Japan thus called for.

  11. Endoscopic Treatment for Early Gastric Cancer

    OpenAIRE

    Kim, Sang Gyun

    2011-01-01

    Endoscopic resection has been accepted as a curative modality for early gastric cancer (EGC). Since conventional endoscopic mucosal resection (EMR) has been introduced, many improvements in endoscopic accessories and techniques have been achieved. Recently, endoscopic submucosal dissection (ESD) using various electrosurgical knives has been performed for complete resection of EGC and enables complete resection of EGC, which is difficult to completely resect in the era of conventional EMR. Cur...

  12. Endoscopic Palliation for Pancreatic Cancer

    Directory of Open Access Journals (Sweden)

    Mihir Bakhru

    2011-04-01

    Full Text Available Pancreatic cancer is devastating due to its poor prognosis. Patients require a multidisciplinary approach to guide available options, mostly palliative because of advanced disease at presentation. Palliation including relief of biliary obstruction, gastric outlet obstruction, and cancer-related pain has become the focus in patients whose cancer is determined to be unresectable. Endoscopic stenting for biliary obstruction is an option for drainage to avoid the complications including jaundice, pruritus, infection, liver dysfunction and eventually failure. Enteral stents can relieve gastric obstruction and allow patients to resume oral intake. Pain is difficult to treat in cancer patients and endoscopic procedures such as pancreatic stenting and celiac plexus neurolysis can provide relief. The objective of endoscopic palliation is to primarily address symptoms as well improve quality of life.

  13. Performance of the EUSO-Balloon electronics

    International Nuclear Information System (INIS)

    Barrillon, P.; Dagoret, S.; Miyamoto, H.; Moretto, C.; Bacholle, S.; Blaksley, C; Gorodetzky, P.; Jung, A.; Prévôt, G.; Prat, P.; Bayer, J.; Blin, S.; Taille, C. De La; Cafagna, F.; Fornaro, C.; Karczmarczyk, J.; Tanco, G. Medina; Osteria, G.; Perfetto, F.; Park, I.

    2016-01-01

    The 24th of August 2014, the EUSO-Balloon instrument went for a night flight for several hours, 40 km above Timmins (Canada) balloon launching site, concretizing the hard work of an important part of the JEM-EUSO collaboration started 3 years before. This instrument consists of a telescope made of two lenses and a complex electronic chain divided in two main sub-systems: the PDM (Photo Detector Module) and the DP (Data Processor). Each of them is made of several innovative elements developed and tested in a short time. This paper presents their performances before and during the flight

  14. Exponential Growth of Nonlinear Ballooning Instability

    International Nuclear Information System (INIS)

    Zhu, P.; Hegna, C. C.; Sovinec, C. R.

    2009-01-01

    Recent ideal magnetohydrodynamic (MHD) theory predicts that a perturbation evolving from a linear ballooning instability will continue to grow exponentially in the intermediate nonlinear phase at the same linear growth rate. This prediction is confirmed in ideal MHD simulations. When the Lagrangian compression, a measure of the ballooning nonlinearity, becomes of the order of unity, the intermediate nonlinear phase is entered, during which the maximum plasma displacement amplitude as well as the total kinetic energy continues to grow exponentially at the rate of the corresponding linear phase.

  15. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  16. Outcomes of intragastric balloon placements in a private practice setting

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth M. H.; Alders, Peter R. H.; Chuttani, Ram; Scherpenisse, Joost

    2015-01-01

    Intragastric balloons are used as a treatment for obesity. Much of the data collected on balloons has been in the context of clinical trials in academic medical centers or as a bridge to bariatric surgery in obesity centers. The aim of this study was to investigate the efficacy and safety of balloon

  17. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...

  18. Playing facilitator

    DEFF Research Database (Denmark)

    Houmøller, Ellen; Marchetti, Emanuela

    2015-01-01

    workshops based on two classic role-play games: The Silent Game (Brandt, 2006) and The Six Thinking Hats (de Bono, 1985). These games were created to support students in learning design thinking in groups and are assigned positive values in literature, hence we expected a smooth process. However, our......t: This paper presents reflections on the role of teachers as facilitators, in a context of role-play targeting learning of design thinking skills. Our study was conducted according to the method of visual ethnography. We acted as facilitators for 50 students through the yearly six-day competitive...... event called InnoEvent, addressed to students in the fields of multimedia and healthcare. Being interested in studying games and role-play as tools to support independent learning in the field of design thinking and team-building, following Dewey’s (1938) theory of learning experience, we ran two...

  19. A systematic review of left ventricular cardio-endoscopic surgery.

    Science.gov (United States)

    Soylu, Erdinc; Kidher, Emaddin; Ashrafian, Hutan; Stavridis, George; Harling, Leanne; Athanasiou, Thanos

    2017-05-25

    Better visualisation, accurate resection and avoidance of ventriculotomy associated with use of endoscopic devices during intracardiac surgery has led to increasing interest in their use. The possibility of combining a cardio-endoscopic technique with either minimally invasive or totally endoscopic cardiac surgery provides an incentive for its further development. Several devices have been used, however their uptake has been limited due to uncertainty around their impact on patient outcomes. A systematic review of the literature identified 34 studies, incorporating 54 subjects undergoing treatment of left ventricular tumours, thrombus or hypertrophic myocardium using a cardio-endoscopic technique. There were no mortalities (0%; 0/47). In 12 studies, the follow-up period was longer than 30 days. There were no post-operative complications apart from one case of atrial fibrillation (2.2%; 1/46). Complete resection of left ventricular lesion was achieved in all cases (100%; 50/50). These successful results demonstrate that the cardio-endoscopic technique is a useful adjunct in resection of left ventricular tumours, thrombus and hypertrophic myocardium. This approach facilitates accurate resection of pathological tissue from left ventricle whilst avoiding exposure related valvular damage and adverse effects associated with ventriculotomy. Future research should focus on designing adequately powered comparative randomised trials focusing on major cardiac and cerebrovascular morbidity outcomes in both the short and long-term. In this way, we may have a more comprehensive picture of both the safety and efficacy of this technique and determine whether such devices could be safely adopted for routine use in minimal access or robotic intra-cardiac surgery.

  20. Reduction effect of bacterial counts by preoperative saline lavage of the stomach in performing laparoscopic and endoscopic cooperative surgery.

    Science.gov (United States)

    Mori, Hirohito; Kobara, Hideki; Tsushimi, Takaaki; Fujihara, Shintaro; Nishiyama, Noriko; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Tani, Joji; Miyoshi, Hisaaki; Morishita, Asahiro; Masaki, Tsutomu

    2014-11-14

    To investigate the effects of gastric lavage with 2000 mL of saline in laparoscopic and endoscopic cooperative surgery. Twenty two patients who were diagnosed with a gastric gastrointestinal stromal tumor were enrolled. In former term, irrigations of the stomach were conducted whenever it was necessary, not systematically (Non systemic lavage group). In latter term, the stomach was thoroughly cleaned with 2000 mL of saline using an endoscope with a water jet, and Duodenal balloon occlusion was conducted to prevent refluxed bile and pancreatic juice (Systemic lavage+balloon occlusion group). The gastric wall was sprayed with 20 mL of distilled water, and 20 mL of gastric juice was collected in a sterile tube and submitted for culture. 20 mL of ascites was also collected from the laparoscopic ports and submitted for culture. We compared WBC, CRP, BT between two groups, and verify the reduction effect of bacterial counts in Systemic lavage+balloon occlusion group. WBC count before, 1 d after, and 3 d after laparoscopic and endoscopic cooperative surgery (LECS) were 5060 (95%CI: 4250-9640), 12140 (6050-14110), and 6910 (5320-12520) in Non systemic lavage group, 4400 (3660-7620), 8910 (6480-10980), and 5950 (4840-7860) in Systemic lavage+balloon occlusion group. Significant differences between two groups at the day after LECS (P = 0.029) and the 3 d after LECS (P = 0.042). CRP levels in Non systemic lavage group and in Systemic lavage+balloon occlusion group were significantly different at the day after LECS (P = 0.005) and the 3 d after LECS (P = 0.028). BTs (°C) in Non systemic lavage group and in Systemic lavage+balloon occlusion group were also significantly different at the day after LECS (P = 0.004) and the 3 d after LECS (P = 0.006). In a logarithmic comparison, bacterial load before gastric lavage, after lavage, and ascites culture were 6.08 (95%CI: 4.04-6.97), 0.48 (0-0.85), and 0.21 (0-0.56). The bacterial counts before and after gastric lavage were

  1. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  2. ENDOSCOPIC BALLOON DILATATION OF ACQUIRED AIRWAY STENOSIS IN NEWBORN-INFANTS - A PROMISING TREATMENT

    NARCIS (Netherlands)

    ELKERBOUT, SC; VANLINGEN, RA; GERRITSEN, J; ROORDA, RJ

    Acquired stenosis of the trachea or bronchus in newborn infants is a possible complication of perinatal intubation and mechanical ventilation. Although the exact pathophysiology is unknown, stenosis formation seems to be initiated by pressure necrosis. Prematurity is thought to be an important risk

  3. Viscoresistive g-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Paris, R.B.

    1980-01-01

    The resistive G-mode and its particular form, the resistive ballooning mode, are treated as limits of a single simple model. MHD theory including parallel and perpendicular viscosity, finite shear, and finite beta is employed to study their linear stability

  4. Treatment of tuberculous bronchostenosis: balloon bronchoplasty

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Im, Jung Gi; Han, Joon Koo; Park, Jae Hyung

    1993-01-01

    The purpose of this study is to evaluate the efficacy of the balloon bronchoplasty in the treatment of the tuberculous bronchostenosis. Balloon bronchoplasty was performed in thirteen patients with stenosis of the left main bronchus (two with combined left upper and lower lobar bronchostenosis) using a inflatable balloon catheter under a fluoroscopic guide. We analysed the changes in the severity of dyspnea and wheezing, serial FEV1/FVC as a parameter of the airflow obstruction, and bronchial diameter and lung volume on chest radiographs. The extent of pulmonary tuberculosis was correlated with the improvement of FEV1/ FVC. There was an improvement of dyspnea in 69% (9/13), decrease of wheezing in 69% (9/13), significant increase of FEV1/FVC in 18% (2/11). The increase of the bronchial diameter and lung volume were seen in 84% (11/13) and 53% (7/13), respectively. The significant increase of FEV1/FVC was seen in 28% (2/7) of the patients with lung involvement of tuberculous less than one third of left upper lobe, whereas there was no increase in those of more than one third. The was no complication except transient leukocytosis, fever and blood-tinged sputum. In conclusion, balloon bronchoplasty is effective in the treatment of medically intractable tuberculous bronchostenosis, and can be considered as an initial method of treatment

  5. Low dose intravaginal misoprostol versus intracervical balloon ...

    African Journals Online (AJOL)

    Background:The efficacy and safety of low dose misoprostol as a ripening agent compared to the widely used balloon catheter in developing countries is undetermined. Objective:To compare the safety and efficacy of a low dose intravaginal misoprostol and intracervical Foley's catheter for cervical ripening. Design:A ...

  6. Double-balloon endoscopy: Who needs it?

    DEFF Research Database (Denmark)

    Hendel, J.W.; Vilmann, P.; Jensen, T.

    2008-01-01

    Objective. Double-balloon endoscopy (DBE) made the small bowel accessible to inspection and therapy in its entirety. However, DBE is a time-consuming procedure that requires a highly skilled endoscopist, several nurses and - more often than not - anesthesiological support. This makes the selection...

  7. Endoscopic ultrasound-guided hepaticogastrostomy and antegrade clearance of biliary lithiasis in patients with surgically-altered anatomy.

    Science.gov (United States)

    Hosmer, Amy; Abdelfatah, Mohamed M; Law, Ryan; Baron, Todd H

    2018-02-01

    Endoscopic retrograde cholangiography (ERC) in patients with complex surgically-altered anatomy (SAA) is technically demanding and has limitations. Developments in EUS-guided procedures allow alternative approaches for patients with altered gastrointestinal anatomy and biliary lithiasis.  Single-center, retrospective review of prospectively entered patients with SAA who underwent EUS-guided hepaticogastrostomy (HGS) followed by an interval antegrade endoscopic clearance of biliary lithiasis.  9 patients with Roux-en-Y anatomy underwent HGS to allow clearance of biliary lithiasis after a mean of 2.5 procedures. Technical success was achieved in 100 % of patients utilizing subsequent antegrade endoscopic techniques after HGS including: balloon sweep (9), transpapillary balloon dilation (8), cholangioscopy with electrohydraulic lithotripsy (4), and mechanical lithotripsy (1). HGS stents were removed in all patients. 1 adverse event (cholangitis) occurred after cholangioscopy and prolonged intraductal electrohydraulic lithotripsy.  EUS-guided antegrade therapy for the management of biliary lithiasis in patients with altered gastrointestinal anatomy appears efficacious with a low risk of adverse events. These preliminary results suggest this approach should be considered at centers with available expertise.

  8. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    Science.gov (United States)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  9. enter endoscopic third ventriculostomy (ETV)

    African Journals Online (AJOL)

    Ventriculoperitoneal 78. Point of View: Exit ventriculoperitoneal shunt; enter endoscopic third ventriculostomy (ETV): contemporary views on hydrocephalus and their implications on management. Abstract. Hydrocephalus has been known to affect humans since the birth of human medicine as it is described by Hippocrates.

  10. Peroral endoscopic myotomy for achalasia

    NARCIS (Netherlands)

    Bredenoord, A. J.; Rösch, T.; Fockens, P.

    2014-01-01

    Treatment of achalasia is complicated by symptom recurrence and a significant risk for severe complications. Endoscopic myotomy was developed in the search for a highly efficacious treatment with lower risks. Since its introduction in 2010, several centers have adopted the technique and published

  11. Endoscopic treatment of orbital tumors.

    Science.gov (United States)

    Signorelli, Francesco; Anile, Carmelo; Rigante, Mario; Paludetti, Gaetano; Pompucci, Angelo; Mangiola, Annunziato

    2015-03-16

    Different orbital and transcranial approaches are performed in order to manage orbital tumors, depending on the location and size of the lesion within the orbit. These approaches provide a satisfactory view of the superior and lateral aspects of the orbit and the optic canal but involve risks associated with their invasiveness because they require significant displacement of orbital structures. In addition, external approaches to intraconal lesions may also require deinsertion of extraocular muscles, with subsequent impact on extraocular mobility. Recently, minimally invasive techniques have been proposed as valid alternative to external approaches for selected orbital lesions. Among them, transnasal endoscopic approaches, "pure" or combined with external approaches, have been reported, especially for intraconal lesions located inferiorly and medially to the optic nerve. The avoidance of muscle detachment and the shortness of the surgical intraorbital trajectory makes endoscopic approach less invasive, thus minimizing tissue damage. Endoscopic surgery decreases the recovery time and improves the cosmetic outcome not requiring skin incisions. The purpose of this study is to review and discuss the current surgical techniques for orbital tumors removal, focusing on endoscopic approaches to the orbit and outlining the key anatomic principles to follow for safe tumor resection.

  12. Colonic perforation following endoscopic retrograde ...

    African Journals Online (AJOL)

    We highlight a potentially lethal complication of acute severe pancreatitis that may not be suspected in severely ill patients. A 41-year-old woman developed acute severe pancreatitis following endoscopic retrograde cholangiopancreatography (ERCP) for suspected choledocholithiasis. When her condition deteriorated ...

  13. An effective and safe gastric endoscopic submucosal dissection in the right lateral position using an inverted overtube.

    Science.gov (United States)

    Mori, Hirohito; Rafiq, Kazi; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Yachida, Tatsuo; Ayagi, Maki; Tani, Joji; Miyoshi, Hisaaki; Masaki, Tsutomu

    2014-02-14

    Previously, we reported the efficacy of a newly developed inverted overtube in shortening the hemostatic time and obtaining a clear endoscopic view in emergency endoscopic hemostasis. This device also helped us to perform gastric endoscopic submucosal dissection (ESD) more safely by changing the direction of gravity in the right lateral position. To perform a safe ESD, it is important to make an appropriate angle and distance between the electric knife and the gastric mucosa. In this position, the distance to gastric mucosa is reduced, and the angle of the electric knife changes from vertical to somewhat oblique, facilitating safer cutting.

  14. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  15. Assessment of Predictive Response Factors to Intragastric Balloon Therapy for the Treatment of Obesity.

    Science.gov (United States)

    Madeira, Eduardo; Madeira, Miguel; Guedes, Erika Paniago; Mafort, Thiago Thomaz; Neto, Leonardo Vieira; de Oliveira Moreira, Rodrigo; de Pinho, Paulo Roberto Alves; Lopes, Agnaldo José; Farias, Maria Lucia Fleiuss

    2016-03-01

    Obesity is a worldwide epidemic that is difficult to control with non-invasive treatments, which usually present poor results. In this context, the intragastric balloon (IGB) is an important tool that presents a mean body weight loss (BWL) estimated at approximately 12%, although individual responses are highly variable. This study assesses whether there are factors that can predict responses to IGB therapy either before or early after placement of the device. A total of 50 obese patients underwent insertion of IGB placed endoscopically, and patients were monitored for 6 months. The evaluated predictive factors involved general characteristics and psychological, social, and dyspeptic aspects, and the preliminary results obtained in the first month after balloon placement. The mean weight loss was 11.5%, and 48% of the participants presented BWL >10%. Among the factors analyzed before IGB placement, only advanced age (P = .04) and higher scores obtained in the social relationships domain of a shorter version of the World Health Organization's Quality of Life questionnaire (P = .02) were significant. Analysis of the factors evaluated after IGB placement revealed that the BWL amounts observed in week 2 (P = .001) and week 4 (P < .001) and the intensity of dyspeptic symptoms in week 2 (P < .001) were positive predictive factors. The assessment of predictive factors may help to manage patients with IGB.

  16. Postoperative vesicoureteral reflux after high-pressure balloon dilation of the ureterovesical junction in primary obstructive megaureter. Incidence, management and predisposing factors.

    Science.gov (United States)

    García-Aparicio, Luis; Blázquez-Gómez, Eva; de Haro, Irene; Garcia-Smith, Natalie; Bejarano, Miguel; Martin, Oriol; Rodo, Joan

    2015-12-01

    To describe the incidence, predisposing factors and management of postoperative vesicoureteral reflux (VUR) after high-pressure balloon dilation to treat primary obstructive megaureter (POM). We have reviewed patients that underwent endoscopic treatment for POM from May 2008 to November 2013. All patients were evaluated with renal ultrasound, voiding cystourethrography and diuretic renogram. Endoscopic treatment was done with high-pressure balloon dilation of the ureterovesical junction under general anesthesia; a double-J stenting was done in all patients. Follow-up was performed with ultrasonography, voiding cystourethrography and a diuretic renogram in all patients. Fifteen boys and five girls with a mean age of 14.18 months (3-103) were reviewed. A total of 22 ureters underwent HPBD to treat POM. Ureterohydronephrosis improves in 19 ureters. After endoscopic treatment, six ureters developed VUR. Four ureters were managed surgically, and in the other two, VUR disappeared in a second cystogram. The presence of parameatal diverticulum in the preoperative cystography and those patients with bilateral POM are factors related to postoperative VUR (p < 0.05). Urinary tract infection after HPBD was observed in four patients, but only one of them was affected with VUR.

  17. A creative analysis of the role of practice development facilitators in ...

    African Journals Online (AJOL)

    Eleven participants from public and private healthcare services reached consensus on seven clusters: theory-practice application, facilitation of learning, increasing collaboration, effective communication, facilitation of change, time management and role modelling. The clusters were visually represented as a hot air balloon.

  18. Prospective evaluation of an indwelling esophageal balloon dilatation feeding tube for treatment of benign esophageal strictures in dogs and cats.

    Science.gov (United States)

    Tan, Desmond K; Weisse, Chick; Berent, Allyson; Lamb, Kenneth E

    2018-03-01

    Despite multiple dilatation procedures, benign esophageal strictures (BES) remain a recurring cause of morbidity and mortality in dogs and cats. Investigate the use of an indwelling Balloon Dilatation esophagostomy tube (B-Tube) for treatment of BES in dogs and cats. Nine dogs and 3 cats. Animals with BES were recruited for our prospective study. Endoscopic and fluoroscopic evaluation of the esophagus and balloon dilatation were performed under general anesthesia, followed by placement of an indwelling B-Tube. The animals' owners performed twice daily at-home inflations for approximately 6 weeks. Repeat endoscopy was performed before B-Tube removal. Animals were reevaluated for changes in modified dysphagia score (MDS) after B-Tube removal. The B-Tube management was relatively well tolerated and effective in maintaining dilatation of a BES while in place. These animals underwent a median of 2 anesthetic episodes and were monitored for a median of 472 days (range, 358-1736 days). The mean MDS before treatment was 3.1 ± 0.5/4.0 and final follow-up MDS were significantly (P dog died. The B-Tube offers an effective, and more economical method, and often decreased anesthetic time to repeated balloon dilatation procedures for the treatment of BES in dogs and cats. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  19. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  20. Novel method to prevent gastric antral strictures after endoscopic submucosal dissection: using triamcinolone.

    Science.gov (United States)

    Nishiyama, Noriko; Mori, Hirohito; Kobara, Hideki; Rafiq, Kazi; Fujihara, Shintaro; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Oryu, Makoto; Masaki, Tsutomu

    2014-09-07

    Endoscopic submucosal dissection (ESD) of large gastric lesions often leads to severe gastric strictures, especially in cases of large ESD in the antrum of the stomach. It has recently been reported that balloon dilation, mucosal incision, and local steroid injections can successfully treat gastric strictures. However, there are some complications with existing methods and decreasing the quality of life. We have developed a novel method to prevent severe gastric strictures that does not involve balloon dilation, mucosal incision, or steroid injections after circumferential ESD. Our original method involves the submucosal injection of a mixed solution composed of triamcinolone acetonide and a general solution of glycerol, hyaluronic acid, and a small amount of indigo carmine and epinephrine during the ESD procedure; this mixture is called a mixed solution of triamcinolone (MST). According to standard ESD procedures, several milliliters of MST are injected into the submucosal layer for the purpose of elevating the submucosa during ESD resulting in prevention of severe strictures. Our method using MST take several advantages such as MST method suppress inflammation in ulcer from initial phase, prevention of stricture without obstructive symptoms, and does not require several ballooning. Therefore, MST method is safe and gentle, shorten the hospitalization duration. Here, we described two cases in which we prevented severe strictures of the gastric antrum after completing a circumferential ESD using MST without any complications.

  1. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J. [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom); Broderick, Nigel [Nottingham University Hospitals, Radiology Department, Nottingham (United Kingdom); Gabra, Hany O.; Elliott, Martin J. [Great Ormond Street Hospital for Children, Department of Cardiothoracic Surgery, London (United Kingdom)

    2010-05-15

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  2. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  3. Development of the local magnification method for quantitative evaluation of endoscope geometric distortion

    Science.gov (United States)

    Wang, Quanzeng; Cheng, Wei-Chung; Suresh, Nitin; Hua, Hong

    2016-05-01

    With improved diagnostic capabilities and complex optical designs, endoscopic technologies are advancing. As one of the several important optical performance characteristics, geometric distortion can negatively affect size estimation and feature identification related diagnosis. Therefore, a quantitative and simple distortion evaluation method is imperative for both the endoscopic industry and the medical device regulatory agent. However, no such method is available yet. While the image correction techniques are rather mature, they heavily depend on computational power to process multidimensional image data based on complex mathematical model, i.e., difficult to understand. Some commonly used distortion evaluation methods, such as the picture height distortion (DPH) or radial distortion (DRAD), are either too simple to accurately describe the distortion or subject to the error of deriving a reference image. We developed the basic local magnification (ML) method to evaluate endoscope distortion. Based on the method, we also developed ways to calculate DPH and DRAD. The method overcomes the aforementioned limitations, has clear physical meaning in the whole field of view, and can facilitate lesion size estimation during diagnosis. Most importantly, the method can facilitate endoscopic technology to market and potentially be adopted in an international endoscope standard.

  4. Angry Birds realized: water balloon launcher for teaching projectile motion with drag

    International Nuclear Information System (INIS)

    Edwards, Boyd F; Sam, David D; Christiansen, Michael A; Booth, William A; Jessup, Leslie O

    2014-01-01

    A simple, collapsible design for a large water balloon slingshot launcher features a fully adjustable initial velocity vector and a balanced launch platform. The design facilitates quantitative explorations of the dependence of the balloon range and time of flight on the initial speed, launch angle, and projectile mass, in an environment where quadratic air drag is important. Presented are theory and experiments that characterize this drag, and theory and experiments that characterize the nonlinear elastic energy and hysteresis of the latex tubing used in the slingshot. The experiments can be carried out with inexpensive and readily available tools and materials. The launcher provides an engaging way to teach projectile motion and elastic energy to students of a wide variety of ages. (paper)

  5. Scoping the scope: endoscopic evaluation of endoscope working channels with a new high-resolution inspection endoscope (with video).

    Science.gov (United States)

    Barakat, Monique T; Girotra, Mohit; Huang, Robert J; Banerjee, Subhas

    2018-02-06

    Outbreaks of transmission of infection related to endoscopy despite reported adherence to reprocessing guidelines warrant scrutiny of all potential contributing factors. Recent reports from ambulatory surgery centers indicated widespread significant occult damage within endoscope working channels, raising concerns regarding the potential detrimental impact of this damage on the adequacy of endoscope reprocessing. We inspected working channels of all 68 endoscopes at our academic institution using a novel flexible inspection endoscope. Inspections were recorded and videos reviewed by 3 investigators to evaluate and rate channel damage and/or debris. Working channel rinsates were obtained from all endoscopes, and adenosine triphosphate (ATP) bioluminescence was measured. Overall endoscope working channel damage was rated as minimal and/or mild and was consistent with expected wear and tear (median 1.59 on our 5-point scale). Our predominant findings included superficial scratches (98.5%) and scratches with adherent peel (76.5%). No channel perforations, stains, or burns were detected. The extent of damage was not predicted by endoscope age. Minor punctate debris was common, and a few small drops of fluid were noted in 42.6% of endoscopes after reprocessing and drying. The presence of residual fluid predicted higher ATP bioluminescence values. The presence of visualized working channel damage or debris was not associated with elevated ATP bioluminescence values. The flexible inspection endoscope enables high-resolution imaging of endoscope working channels and offers endoscopy units an additional modality for endoscope surveillance, potentially complementing bacterial cultures and ATP values. Our study, conducted in a busy academic endoscopy unit, indicated predominately mild damage to endoscope working channels, which did not correlate with elevated ATP values. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights

  6. Evolution of scientific ballooning and its impact on astrophysics research

    Science.gov (United States)

    Jones, William Vernon

    2014-05-01

    As we celebrate the centennial year of the discovery of cosmic rays on a manned balloon, it seems appropriate to reflect on the evolution of ballooning and its scientific impact. Balloons have been used for scientific research since they were invented in France more than 200 years ago. Ballooning was revolutionized in 1950 with the introduction of the so-called natural shape balloon with integral load tapes. This basic design has been used with more or less continuously improved materials for scientific balloon flights for more than a half century, including long-duration balloon (LDB) flights around Antarctica for the past two decades. The U.S. National Aeronautics and Space Administration (NASA) is currently developing the next generation super-pressure balloon that would enable extended duration missions above 99.5% of the Earth's atmosphere at any latitude. The Astro2010 Decadal Survey report supports super-pressure balloon development and the giant step forward it offers with ultra-long-duration balloon (ULDB) flights at constant altitudes for about 100 days.

  7. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  8. [Endoscopic surgery of hemorrhagic stroke].

    Science.gov (United States)

    Dash'ian, V G; Korshikova, A N; Godkov, I M; Krylov, V V

    2014-01-01

    Objectives. Demonstration and analysis of possibilities of video-endoscopy in the surgical treatment of hypertensive hemorrhages Materials and methods. We analyzed the results of surgical treatment of 35 patients with hypertensive intracranial hematomas which were removed using endoscopic method. Twenty-eight patients had putamen, 3 thalamic, 3 cerebellar and 1 subcortical hematoma; the volume of hematomas ranged from 14 to 84 cm3. Results. Neurological lesions completely disappeared in 7 patients, 6 patients had moderate and 17 severe disability. Five (14%) patients died. Outcome of treatment was significantly (psurgery, localization of the hemorrhage, presence and degree of transverse brain dislocation, repeated hemorrhages. Risk factors for poor outcome were depressed consciousness, recurrent hemorrhages, the transverse dislocation >6 mm and deep intracranial hematoma. Conclusions. The efficacy of endoscopic aspiration of hematomas is comparable to open surgical interventions but less traumatic.

  9. Retrograde prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    The authors performed retrograde prostatic urethroplasty in 18 patients using a 25-mm urethroplasty balloon catheter. The procedure was performed on an outpatient basis under local anesthesia. Voiding cystourethrography, retrograde urethrography, rectal US, and MRE imaging were performed before and immediately after the procedure and at 2 weeks and 3, 6, 12, and 18 months. Long-term results at 18 months and possible clinical implications are discussed

  10. Endoscopic Management of Posterior Epistaxis

    OpenAIRE

    Paul, J.; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-01-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26–50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of ...

  11. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  12. Long Duration Balloon Charge Controller Stack Integration

    Science.gov (United States)

    Clifford, Kyle

    NASA and the Columbia Scientific Balloon Facility are interested in updating the design of the charge controller on their long duration balloon (LDB) in order to enable the charge controllers to be directly interfaced via RS232 serial communication by a ground testing computers and the balloon's flight computer without the need to have an external electronics stack. The design involves creating a board that will interface with the existing boards in the charge controller in order to receive telemetry from and send commands to those boards, and interface with a computer through serial communication. The inputs to the board are digital status inputs indicating things like whether the photovoltaic panels are connected or disconnected; and analog inputs with information such as the battery voltage and temperature. The outputs of the board are 100ms duration command pulses that will switch relays that do things like connect the photovoltaic panels. The main component of this design is a PIC microcontroller which translates the outputs of the existing charge controller into serial data when interrogated by a ground testing or flight computer. Other components involved in the design are an AD7888 12-bit analog to digital converter, a MAX3232 serial transceiver, various other ICs, capacitors, resistors, and connectors.

  13. Intragastric balloon for treatment-resistant obesity: safety, tolerance, and efficacy of 1-year balloon treatment followed by a 1-year balloon-free follow-up

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth M. H.; Tytgat, Guido N. J.

    2005-01-01

    Background: Prior efforts to treat obesity with intragastric balloons were thwarted by high complication rates. Therefore, fundamental requirements for optimal balloon designs were defined. The aim of the present study was to investigate the effectiveness, the safety; and the tolerance of a new

  14. Endoscopic Aspects of Gastric Syphilis

    Directory of Open Access Journals (Sweden)

    Mariana Souza Varella Frazão

    2012-01-01

    Full Text Available Introduction. Considered as a rare event, gastric syphilis (GS is reported as an organic form of involvement. Low incidence of GS emphasizes the importance of histopathological analysis. Objective. We aim to characterize GS endoscopic aspects in an immunocompetent patient. Case Report. A 23-year-old man presented with epigastric pain associated with nausea, anorexia, generalized malaise and 11 kg weight loss that started 1 month prior to his clinical consultation. Physical examination was normal except for mild abdominal tenderness in epigastrium. Endoscopy observed diminished gastric expandability and diffuse mucosal lesions, from cardia to pylorus. Gastric mucosa was thickened, friable, with nodular aspect, and associated with ulcers lesions. Gastric biopsies were performed, and histopathological analysis resulted in dense inflammatory infiltration rich in plasmocytes. Syphilis serologies were positive for VDRL and Treponema pallidum reagents. Immunohistochemical tests were positive for Treponema pallidum and CD138. The patient was treated with penicillin, leading to resolution of his clinical complaints and endoscopic findings. Conclusion. Diagnosis suspicion of GS is important in view of its nonspecific presentation. Patients with gastric symptoms that mimic neoplastic disease should be investigated thoroughly based on the fact that clinical, endoscopic, and histological findings can easily be mistaken for lymphoma or plastic linitis.

  15. Endoscopic treatment of esophageal achalasia

    Science.gov (United States)

    Esposito, Dario; Maione, Francesco; D’Alessandro, Alessandra; Sarnelli, Giovanni; De Palma, Giovanni D

    2016-01-01

    Achalasia is a motility disorder of the esophagus characterized by dysphagia, regurgitation of undigested food, chest pain, weight loss and respiratory symptoms. The most common form of achalasia is the idiopathic one. Diagnosis largely relies upon endoscopy, barium swallow study, and high resolution esophageal manometry (HRM). Barium swallow and manometry after treatment are also good predictors of success of treatment as it is the residue symptomatology. Short term improvement in the symptomatology of achalasia can be achieved with medical therapy with calcium channel blockers or endoscopic botulin toxin injection. Even though few patients can be cured with only one treatment and repeat procedure might be needed, long term relief from dysphagia can be obtained in about 90% of cases with either surgical interventions such as laparoscopic Heller myotomy or with endoscopic techniques such pneumatic dilatation or, more recently, with per-oral endoscopic myotomy. Age, sex, and manometric type by HRM are also predictors of responsiveness to treatment. Older patients, females and type II achalasia are better after treatment compared to younger patients, males and type III achalasia. Self-expandable metallic stents are an alternative in patients non responding to conventional therapies. PMID:26839644

  16. Endoscopic management of posterior epistaxis.

    Science.gov (United States)

    Paul, J; Kanotra, Sohit Paul; Kanotra, Sonika

    2011-04-01

    The traditional method of management of posterior epistaxis has been with anteroposterior nasal packing. Apart from the high failure rate of 26-50% reported in various series, nasal packing is associated with marked discomfort and several complications. In order to avoid nasal packing, we started doing endoscopic cauterization in cases of posterior epistaxis. A total of 23 patients with posterior epistaxis were subjected to nasal endoscopy with the intent to stop bleeding by cauterization of the bleeding vessel. Of these, in four cases unsuspected diagnosis was made. Of the remaining 19, in three patients, the bleeding point could not be localized accurately and these patients were managed by anteroposterior packing. The rest of the 16 patients were managed by endoscopic cauterization. In four patients, there was recurrence of bleeding within 24 h. In one of these, cauterization controlled the bleeding while in the rest nasal packing had to be resorted to. Thus, of the 23 patients of posterior epistaxis subjected to nasal endoscopy, we could avoid nasal packing in 17 (74%). To conclude, endoscopic nasal cauterization is recommended as the first line to treatment in all cases of posterior epistaxis. This will not only prevent the uncomfortable and potentially dangerous nasal packing but also help in finding the underlying pathology.

  17. Endoscopically removed giant submucosal lipoma

    Directory of Open Access Journals (Sweden)

    Jovanović Ivan

    2007-01-01

    Full Text Available Background. Although uncommon, giant submucosal colon lipomas merit attention as they are often presented with dramatic clinical features such as bleeding, acute bowel obstruction, perforation and sometimes may be mistaken for malignancy. There is a great debate in the literature as to how to treat them. Case report. A patient, 67-year old, was admitted to the Clinic due to a constipation over the last several months, increasing abdominal pain mainly localized in the left lower quadrant accompanied by nausea, vomiting and abdominal distension. Physical examination was unremarkable and the results of the detailed laboratory tests and carcinoembryonic antigen remained within normal limits. Colonoscopy revealed a large 10 cm long, and 4 to 5 cm in diameter, mobile lesion in his sigmoid colon. Conventional endoscopic ultrasound revealed 5 cm hyperechoic lesion of the colonic wall. Twenty MHz mini-probe examination showed that lesion was limited to the submucosa. Since polyp appeared too large for a single transaction, it was removed piecemeal. Once the largest portion of the polyp has been resected, it was relatively easy to place the opened snare loop around portions of the residual polyp. Endoscopic resection was carried out safely without complications. Histological examination revealed the common typical histological features of lipoma elsewhere. The patient remained stable and eventually discharged home. Four weeks later he suffered no recurrent symptoms. Conclusion. Colonic lipomas can be endoscopically removed safely eliminating unnecessary surgery.

  18. Direct percutaneous endoscopic jejunostomy in pediatric age with a pexies triangulation system: report of a case and literature review

    Directory of Open Access Journals (Sweden)

    Fernando Alberca-de-las-Parras

    2015-04-01

    Full Text Available Direct percutaneous endoscopic jejunostomy (DPEJ is an infrequent procedure as it is not always easy to obtain transillumination, being this the main reason for failure of this technique. In patients with previous surgery, this procedure is more complex and there are only 6 reported cases in pediatric population. In our case, we provide the use of an endoscopic triangulation system with "T" pexies not used before in these cases. With this technique, we guarantee not to replace the introduction system afterwards, obtaining the placement of a balloon fixation system initially. We also provide several improvements that helped us developing the procedure: Placement of the jejunostomy through a gastrostomy; use of water column to avoid penetration in hollow viscus; use of a guide wire, and a triangulation pexy system.

  19. Management of Nodular Neoplasia in Barrett's Esophagus: Endoscopic Mucosal Resection and Endoscopic Submucosal Dissection

    NARCIS (Netherlands)

    Belghazi, Kamar; Bergman, Jacques J. G. H. M.; Pouw, Roos E.

    2017-01-01

    Endoscopic resection has proven highly effective and safe in the removal of focal early neoplastic lesions in Barrett's esophagus and is considered the cornerstone of endoscopic treatment. Several techniques are available for endoscopic resection in Barrett's esophagus. The most widely used

  20. Asymptomatic Esophageal Varices Should Be Endoscopically Treated

    Directory of Open Access Journals (Sweden)

    Nib Soehendra

    1998-01-01

    Full Text Available Endoscopic treatment has generally been accepted in the management of bleeding esophageal varices. Both the control of acute variceal bleeding and elective variceal eradication to prevent recurrent bleeding can be achieved via endoscopic methods. In contrast to acute and elective treatment, the role of endoscopic therapy in asymptomatic patients who have never had variceal bleeding remains controversial because of the rather disappointing results obtained from prophylactic sclerotherapy. Most published randomized controlled trials showed that prophylactic sclerotherapy had no effect on survival. In some studies, neither survival rate nor bleeding risk was improved. In this article, the author champions the view that asymptomatic esophageal varices should be endoscopically treated.

  1. Endoscopic full-thickness resection: Current status.

    Science.gov (United States)

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-08-21

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.

  2. The impact of balloon catheter dilation on frequency of sinus surgery in the United States

    Directory of Open Access Journals (Sweden)

    Holy CE

    2014-04-01

    Full Text Available Chantal E Holy,1 John M Ellison,1 Charles Schneider,1 Howard L Levine2,3 1Health Economics and Reimbursement, 2Medical Affairs, Acclarent Inc., a Johnson & Johnson Company, Menlo Park, CA, USA; 3Cleveland Nasal-Sinus and Sleep Center, Cleveland, OH, USA Purpose: Endoscopic sinus surgery for patients with chronic rhinosinusitis (CRS unresponsive to medical therapy has traditionally been performed under general anesthesia and in the operating room. Balloons for catheter dilation of paranasal sinuses were introduced in 2005, allowing sinus surgery to be safely performed either in the operating room or the office care setting, under local anesthesia. This change in care setting has raised concerns of overuse or expanded indications for sinus surgery. This study was thus designed to evaluate changes in surgical volumes in the United States, for the period 2006–2011, and to evaluate the impact of the sinus balloons on surgical practice. Methods: The MarketScan® Commercial Claims and Encounter Database was queried for the period 2006 to 2011 using CRS International Classification of Diseases, Ninth Revision codes (473.X and sinus surgery US-based Common Procedural Terminology (CPT codes (endoscopic sinus surgery: CPT codes 31254–31294 and 31299; balloon catheter dilation: CPT codes 31295–31297. MarketScan's projection methodology was applied to estimate the nationwide prevalence of CRS and the incidence of sinus surgery. Procedural case mix and total average payment per surgery were analyzed. Results: From 2006 to 2011, the yearly prevalence of CRS and sinus surgery volume remained flat with ~430 patients with CRS per 100,000 in the employer-sponsored insured population, of which ~117/100,000 underwent surgery. In 2006, 2.69 paranasal sinuses (95% confidence interval [95% CI]: 2.65–2.71 were treated during each individual sinus surgery, with an additional 1.11 nasal procedures (95% CI: 1.08–1.13 performed concurrently. By 2011, the

  3. Energetic funnel facilitates facilitated diffusion.

    Science.gov (United States)

    Cencini, Massimo; Pigolotti, Simone

    2018-01-25

    Transcription factors (TFs) are able to associate to their binding sites on DNA faster than the physical limit posed by diffusion. Such high association rates can be achieved by alternating between three-dimensional diffusion and one-dimensional sliding along the DNA chain, a mechanism-dubbed facilitated diffusion. By studying a collection of TF binding sites of Escherichia coli from the RegulonDB database and of Bacillus subtilis from DBTBS, we reveal a funnel in the binding energy landscape around the target sequences. We show that such a funnel is linked to the presence of gradients of AT in the base composition of the DNA region around the binding sites. An extensive computational study of the stochastic sliding process along the energetic landscapes obtained from the database shows that the funnel can significantly enhance the probability of TFs to find their target sequences when sliding in their proximity. We demonstrate that this enhancement leads to a speed-up of the association process. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  4. Endoscopic band ligation and endoscopic hemoclip placement for patients with Mallory-Weiss syndrome and active bleeding

    OpenAIRE

    Cho, Young-Seok; Chae, Hiun-Suk; Kim, Hyung-Keun; Kim, Jin-Soo; Kim, Byung-Wook; Kim, Sung-Soo; Han, Sok-Won; Choi, Kyu-Yong

    2008-01-01

    AIM: To compare the hemostatic efficacy and safety of two mechanical endoscopic methods: endoscopic band ligation (EBL) and endoscopic hemoclip placement (EHP) in patients with actively bleeding Mallory-Weiss syndrome (MWS).

  5. Developing Modularized Virtual Reality Simulators for Natural Orifice Translumenal Endoscopic Surgery (NOTES).

    Science.gov (United States)

    Ahn, Woojin; Dorozhkin, Denis; Schwaitzberg, Steven; Jones, Daniel B; De, Suvranu

    2016-01-01

    Natural orifice translumenal endoscopic surgery (NOTES) procedures are rapidly being developed in diverse surgical fields. We are developing a Virtual Translumenal Endoscopic Surgery Trainer (VTEST™) built on a modularized platform that facilitates rapid development of virtual reality (VR) NOTES simulators. Both the hardware interface and software components consist of independent reusable and customizable modules. The developed modules are integrated to build a VR-NOTES simulator for training in the hybrid transvaginal NOTES cholecystectomy. The simulator was demonstrated and evaluated by expert NOTES surgeons at the 2015 Natural Orifice Surgery Consortium for Assessment and Research (NOSCAR) summit.

  6. Anesthesia for Routine and Advanced Upper Gastrointestinal Endoscopic Procedures.

    Science.gov (United States)

    Sharp, Christopher D; Tayler, Ezekiel; Ginsberg, Gregory G

    2017-12-01

    This article aims to detail the breadth and depth of advanced upper gastrointestinal endoscopic procedures. It will focus on sedation and airway management concerns pertaining to this emerged and emerging class of minimally invasive interventions. The article will also cover endoscopic hemostasis, endoscopic resection, stenting and Barrett eradication therapy plus endoscopic ultrasound. It additionally will address the nuances of endoscopic retrograde cholangiopancreatography and new natural orifice transluminal endoscopic surgery procedures including endoscopic cystgastrostomy and the per-oral endoscopic myotomy procedure. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Superpressure Balloon Design Using Nonlinear Viscoelasticity

    Science.gov (United States)

    Rand, James; Rand, James; Wakefield, David

    Stratospheric balloon platforms are used extensively by scientists for a variety of purposes. The typical balloon used today is the zero pressure natural shape fabricated from a thin film of linear low density polyethylene. This material has been found to possess a variety of desirable characteristics suitable to this environment. This film will remain ductile at very low temperatures which will permit it to develop large strains if necessary to satisfy equilibrium considerations. However, in order to achieve long duration flight without significant changes in altitude, the balloon should be pressurized to the extent necessary to maintain constant volume during typical variations in temperature. In the past, pressurized balloons were fabricated from other materials in order to achieve significant increases in strength. Thin films of polyester or polyimide have been used to make relatively small spheres capable of long duration flight. Unfortunately, these materials do not have the ductility of polyethylene at low temperature and are somewhat more fragile and subject to damage. In recent years various organizations have attempted to use the characteristic shape of a pumpkin to limit the stresses in a balloon envelope to that which can be accommodated by laminated fabric materials. While developing the design, analysis and construction techniques for this type of system, the use of polyethylene has been successfully demonstrated to provide a reliable envelope. This shape is achieved by using high strength members in the meridional direction to carry the very high loads generated by the pressure. These so called "tendons" have very low elongation and serve to limit the deformation of the film in that direction. However, earlier designs attempted to limit the stresses in the circumferential direction by using a lobe angle to control the stress. Unfortunately this has led to a number of stability problems with this type of balloon. In order to control the stability of

  8. Endoscopic Stenting and Clipping for Anastomotic Stricture and Persistent Tracheoesophageal Fistula after Surgical Repair of Esophageal Atresia in an Infant

    Directory of Open Access Journals (Sweden)

    Mohammed Amine Benatta

    2014-01-01

    Full Text Available Anastomotic stricture (AS and recurrent tracheoesophageal fistula (TEF are two complications of surgical repair of esophageal atresia (EA. Therapeutic endoscopic modalities include stenting, tissue glue, and clipping for TEF and endoscopic balloon dilation bougienage and stenting for esophageal strictures. We report herein a two-month infant with both EA and TEF who benefited from a surgical repair for EA, at the third day of life. Two months later he experienced deglutition disorders and recurrent chest infections. The esophagogram showed an AS and a TEF confirmed with blue methylene test at bronchoscopy. A partially covered self-expanding metal type biliary was endoscopically placed. Ten weeks later the stent was removed. This allows for easy passage of the endoscope in the gastric cavity but a persistent recurrent fistula was noted. Instillation of contrast demonstrated a fully dilated stricture but with a persistent TEF. Then we proceeded to placement of several endoclips at the fistula site. The esophagogram confirmed the TEF was obliterated. At 12 months of follow-up, he was asymptomatic. Stenting was effective to alleviate the stricture but failed to treat the TEF. At our knowledge this is the second case of successful use of endoclips placement to obliterate recurrent TEF after surgical repair of EA in children.

  9. [Balloon cell nevi of the conjunctiva (author's transl)].

    Science.gov (United States)

    Schlageter, P E; Daicker, B

    1975-06-01

    The clinical and histological features of three cases of conjunctival balloon cell nevi are described. This peculiar form of nevus is very rare in the conjunctiva. The findings are compared with the descriptions in the literature of dermal balloon cell nevi. They demonstrate, that the conjunctival and dermal tumours are of idential histological structure. The proliferations of the conjunctival epithelium often found in conjunctival nevi do not modify the balloon cell nevi. These can not be diagnosed clinically. The problems of the pathogenesis of the balloon cell nevi are discussed.

  10. Advanced Li batteries for terrestrial balloons, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — For future advanced terrestrial balloon missions, NASA requires energy dense and power dense energy storage solutions significantly exceeding the performance of...

  11. Hyperspectral Polarimeter for Monitoring Balloon Strain, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously unattainable...

  12. Deflation of gastric band balloon in pregnancy for improving outcomes.

    Science.gov (United States)

    Jefferys, Amanda E; Siassakos, Dimitrios; Draycott, Tim; Akande, Valentine A; Fox, Robert

    2013-04-30

    In line with the rise in the prevalence of obesity, an increasing number of women of childbearing age are undergoing laparoscopic adjustable gastric banding (LAGB), resulting in an increasing number of pregnancies with a band in place. Currently, there is no consensus on optimal band management in pregnancy. Some clinicians advocate leaving the band balloon inflated to reduce gestational weight gain and associated adverse perinatal outcomes. However, there are concerns that maintaining balloon inflation during pregnancy might increase the risk of band complications and adversely affect fetal development and/or growth as a result of reduced nutritional intake. To compare maternal and perinatal outcomes for elective gastric band balloon deflation versus intention to maintain balloon inflation during pregnancy. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2012) and the Web of Science database (1940 to September 2012). Randomised-controlled trials comparing elective deflation of the gastric band balloon with intention to maintain balloon inflation in pregnant women who have undergone LAGB. Two review authors independently assessed studies for inclusion. No studies met the criteria for inclusion in the review. To date no randomised controlled trials exist that compare elective deflation of the gastric band balloon in pregnancy versus intention to maintain balloon inflation. Further research is needed to define the optimum management of the gastric band balloon in pregnancy.

  13. An Overview of Current and Future Stratospheric Balloon Mission Capabilities

    Science.gov (United States)

    Smith, Michael

    The modern stratospheric balloon has been used for a variety of missions since the late 1940's. Capabilities of these vehicles to carry larger payloads, fly to higher altitudes, and fly for longer periods of time have increased dramatically over this time. In addition to these basic performance metrics, reliability statistics for balloons have reached unprecedented levels in recent years. Balloon technology developed in the United States in the last decade has the potential to open a new era in economical space science using balloons. As always, the advantage of the balloon platform is the fact that missions can be carried out at a fraction of the cost and schedule of orbital missions. A secondary advantage is the fact that instruments can be re-flown numerous times while upgrading sensor and data processing technologies from year to year. New mission capabilities now have the potential for enabling ground breaking observations using balloons as the primary platform as opposed to a stepping stone to eventual orbital observatories. The limit of very high altitude balloon missions will be explored with respect to the current state of the art of balloon materials and fabrication. The same technological enablers will also be applied to possibilities for long duration missions at mid latitudes with payloads of several tons. The balloon types and their corresponding mission profiles will be presented in a performance matrix that will be useful for potential scientific users in planning future research programs.

  14. Severity of post-ERCP pancreatitis directly proportional to the invasiveness of endoscopic intervention: a pilot study in a canine model.

    Science.gov (United States)

    Buscaglia, J M; Simons, B W; Prosser, B J; Ruben, D S; Giday, S A; Magno, P; Clarke, J O; Shin, E J; Kalloo, A N; Kantsevoy, S V; Gabrielson, K L; Jagannath, S B

    2008-06-01

    Pancreatitis complicates 1% - 22% of endoscopic retrograde cholangiopancreatography procedures. The study aims were to develop a reproducible animal model of post-ERCP pancreatitis (PEP), and investigate the impact of endoscopic technique on severity of PEP. ERCP was carried out in six male hound dogs. Pancreatitis was induced by one of three escalating methods: 1) pancreatic acinarization with 20 - 30 mL of contrast; 2) acinarization + ductal balloon occlusion + sphincterotomy; 3) acinarization + intraductal synthetic bile injection + ductal balloon occlusion + sphincterotomy. Dogs 5 and 6 received a pancreatic stent. Necropsy was performed on postoperative day 5. All pancreatic specimens were graded by two blinded pathologists according to a validated scoring system. All dogs were compared with three control dogs. Dogs 1 - 4 developed clinical pancreatitis and hyperamylasemia (11 736 vs. 722 U/L, P = 0.02). Total injury scores were significantly elevated compared with controls (6.85 vs. 1.06, P = 0.004). There was significant increase in acinar cell necrosis (0.86 vs. 0.06, P = Dogs 5 and 6 developed clinical pancreatitis without significant hyperamylasemia; total injury scores were elevated compared with controls (4.83 vs. 1.06, P = 0.01), but lower than in Dogs 1 - 4 (4.83 vs. 6.85, P = 0.25). There was escalating severity of pancreatic injury from Dogs 1 to 4 correlating with the method of endoscopic injury used. Severity of PEP is directly proportional to invasiveness of endoscopic intervention. Pancreatic acinarization, even without balloon occlusion and sphincterotomy, can be used as a reliable animal model for future studies investigating therapy and prevention of disease.

  15. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with

  16. Endoscopic ultrasound-guided endoscopic necrosectomy of the pancreas: is irrigation necessary?

    Science.gov (United States)

    Jürgensen, Christian; Neser, Frank; Boese-Landgraf, Joachim; Schuppan, Detlef; Stölzel, Ulrich; Fritscher-Ravens, Annette

    2012-05-01

    Findings have shown endoscopic necrosectomy to be beneficial for patients with symptomatic pancreatic necrosis accessible for an endoscopic approach. The available studies show that endoscopic necrosectomy requires a multitude of subsequent procedures including repeat irrigation for removal of the necrotic material. This study aimed to investigate the need for additional irrigation in patients with necrotizing pancreatitis treated by endoscopic necrosectomy. The study enrolled 35 consecutive patients (27 men) with a median age of 59 years who had pancreatic necrosis treated with endoscopic necrosectomy. Endoscopic ultrasound-guided internal drainage and consecutive endoscopic necrosectomy was combined with interval multistenting of the cavity. Neither endoscopic nor external irrigation was part of the procedure. An average of 6.2 endoscopy sessions per patient were needed for access, necrosectomy, and stent management. The in-hospital mortality rate was 6% (2/35), including one procedure-related death resulting from postinterventional aspiration. The immediate morbidity rate was 9% (3/35). It was possible to achieve clinical remission for all the surviving patients with no additional surgery needed for management of the necroses. The median follow-up period was 23 months. Neither endoscopic nor external flushing is needed for successful endoscopic treatment of symptomatic necroses. Even without irrigation, the outcome for patients treated with endoscopic necrosectomy is comparable to that described in the published data.

  17. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    Science.gov (United States)

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  18. Quantitative angiographic comparison of elastic recoil after coronary excimer laser-assisted balloon angioplasty and balloon angioplasty alone.

    Science.gov (United States)

    Strikwerda, S; van Swijndregt, E M; Melkert, R; Serruys, P W

    1995-02-01

    Coronary lumen changes during and after excimer laser-assisted balloon angioplasty were measured by quantitative coronary angiography, and the results were compared with the effects of balloon angioplasty alone. Reduction of atherosclerotic tissue mass by laser ablation in the treatment of coronary artery disease may be more effective in enlarging the lumen than balloon angioplasty alone. A series of 57 consecutive coronary lesions successfully treated by xenon chloride excimer laser-assisted balloon angioplasty were individually matched with 57 coronary artery lesions successfully treated by balloon angioplasty alone. The following variables were measured by quantitative coronary analysis: 1) ablation by laser, 2) stretch by balloon dilation, 3) elastic recoil, and 4) acute gain. Matching by stenosis location, reference diameter and minimal lumen diameter resulted in two comparable groups of 57 lesions with identical baseline stenosis characteristics. Minimal lumen diameter before excimer laser-assisted balloon angioplasty and balloon angioplasty alone were (mean +/- SD) 0.73 +/- 0.44 and 0.74 +/- 0.43 mm, respectively. Laser ablation significantly improved minimal lumen diameter by 0.56 +/- 0.44 mm before adjunctive balloon dilation. In both treatment groups, similar-sized balloon catheters (2.59 +/- 0.35 and 2.56 +/- 0.40 mm, respectively) were used. After laser-assisted balloon angioplasty, elastic recoil was 0.84 +/- 0.30 mm (32% of balloon size), which was identical to that after balloon angioplasty alone, namely, 0.82 +/- 0.32 mm (32%). Consequently, both interventions resulted in similar acute gains of 1.02 +/- 0.52 and 1.00 +/- 0.56 mm, respectively. Minimal lumen diameter after intervention was equal in both groups: 1.75 +/- 0.35 and 1.75 +/- 0.34 mm, respectively. The statistical power of this study in which a 25% difference in elastic recoil (0.2 mm) between groups was considered clinically important was 95%. In matched groups of successfully treated

  19. Permanent endovascular balloon occlusion of the vertebral artery as an adjunct to the surgical resection of selected cervical spine tumors: A single center experience.

    Science.gov (United States)

    Ogungbemi, Ayokunle; Elwell, Vivien; Choi, David; Robertson, Fergus

    2015-08-01

    Complete surgical resection of cervical spine tumors is often challenging when there is tumor encasement of major neck vessels. Pre-operative endovascular sacrifice of the major vessels can facilitate safe tumor resection. The use of transarterial detachable coils has been described in this setting, but it can be time-consuming and costly to occlude a patent parent vessel using this method. Our aim was to evaluate the safety and effectiveness of our endovascular detachable balloon occlusion technique, performed without prior balloon test occlusion in the pre-operative management of these tumors. We retrospectively reviewed 18 consecutive patients undergoing pre-operative unilateral permanent endovascular balloon occlusion of tumor-encased vertebral arteries in our institution. Procedure-related ischemic or thromboembolic complication was defined as focal neurologic deficit attributable to the endovascular occlusion which occurs before subsequent surgical resection. Successful pre-operative endovascular vertebral artery sacrifice using detachable balloons was achieved in 100% (n = 18) of cases without prior balloon test occlusion. Procedural complication rate was 5.6% as one patient developed transient focal neurology secondary to a delayed cerebellar infarct at home on day 11 and subsequently made a full recovery. There were no cases of distal balloon migration. Complete macroscopic resection of tumor as reported by the operating surgeon was achieved in 89% of cases. Pre-operative endovascular sacrifice of the vertebral artery using detachable balloons and without prior balloon test occlusion is a safe procedure with low complication rates and good surgeon reported rates of total resection. © The Author(s) 2015.

  20. RESEARCH Endoscopic injection sclerotherapy for bleeding varices ...

    African Journals Online (AJOL)

    RESEARCH. 884 November 2012, Vol. 102, No. 11 SAMJ. Endoscopic injection sclerotherapy for bleeding varices in children with intrahepatic and extrahepatic portal venous ... Progress has been made in developing newer endoscopic techniques ... a sclerosant, usually 0.5 - 0.75 ml per injection, at multiple (up to.

  1. Towards automated visual flexible endoscope navigation

    NARCIS (Netherlands)

    van der Stap, N.; van der Heijden, Ferdinand; Broeders, Ivo Adriaan Maria Johannes

    2013-01-01

    Background The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now

  2. Duodenal diverticular bleeding: an endoscopic challenge

    Directory of Open Access Journals (Sweden)

    Eduardo Valdivielso-Cortázar

    Full Text Available Duodenal diverticula are an uncommon cause of upper gastrointestinal bleeding. Until recently, it was primarily managed with surgery, but advances in the field of endoscopy have made management increasingly less invasive. We report a case of duodenal diverticular bleeding that was endoscopically managed, and review the literature about the various endoscopic therapies thus far described.

  3. Endoscopic third ventriculostomy in idiopathic normal pressure ...

    African Journals Online (AJOL)

    Objective: To determine the efficacy of endoscopic fenestration of the third ventricle in the treatment of idiopathic normal pressure hydrocephalus. Methods: 16 patients with idiopathic normal pressure hydrocephalus were treated by endoscopic third ventriculostomy. This study lasted three years. All patients were over 50 ...

  4. Endoscopic management of bile leaks after laparoscopic ...

    African Journals Online (AJOL)

    Of 84 patients managed endoscopically, 44 had a cystic duct (CD) leak, 26 a CD leak and common bile duct (CBD) stones, and 14 a CBD injury amenable to endoscopic stenting. Of the 70 patients with CD leaks (group A), 24 underwent sphincterotomy only (including 8 stone extractions), 43 had a sphincterotomy with stent ...

  5. Prophylactic balloon occlusion of internal iliac arteries in women with placenta accreta: Literature review and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dilauro, M.D.; Dason, S. [McMaster University, Michael G. DeGroote School of Medicine (Canada); Athreya, S., E-mail: sathreya@stjoes.ca [Diagnostic Imaging, St Joseph' s Healthcare Hamilton, Ontario (Canada)

    2012-06-15

    Aim: To review the literature on the use of prophylactic balloon occlusion alone and in conjunction with arterial embolization of the internal iliac arteries in women with placenta accreta. Materials and methods: The PubMed, MEDLINE, CINAHL, EMBASE, and Cochrane Library databases were searched for keywords related to this technique and its use in the avoidance of caesarean hysterectomy. The relevant published articles were selected and then searched for further references. Results: The literature search found 15 case reports and five studies for a total of 20 articles. The use of balloon catheters to prevent post-partum haemorrhage in women with placenta accreta is controversial with some investigators reporting reduced blood loss and transfusion requirements while others reporting no benefit. This procedure does not appear to reduce operative time or hospital stay. Some groups have described catheter-related complications, such as maternal thromboembolic events and the need for stent placement and/or arterial bypass. Thus far, there is no reported maternal or foetal mortality related to this procedure. Conclusion: Current evidence is based upon case reports and small retrospective studies. Larger studies or randomized controlled trials are essential in order to demonstrate the safety and efficacy of bilateral iliac balloon occlusion. The creation of a data registry would also facilitate the reporting of this technique.

  6. Trans-Balloon Visualisation During Dilatation (TBVD) of Oesophageal Strictures: a Novel Innovation.

    Science.gov (United States)

    Khokhar, Haseeb A; Azeem, Beenish; Bughio, Mumtaz; Bass, Gary A; Elfadul, Amr; Salih, Monim; Fahmy, Waleed; Walsh, Thomas N

    2016-04-01

    Hydrostatic balloon dilatation of upper gastrointestinal strictures is associated with a risk of perforation that varies with the underlying pathology and with the technique employed. We present a technique of trans-balloon visualisation of the stricture during dilatation (TBVD) that allows direct 'real-time' observation of the effect of dilatation on the stricture, facilitating early recognition of mucosal abruption, thereby reducing the perforation rate. We retrospectively analysed 100 consecutive patients, undergoing balloon dilatation of oesophageal strictures between 1st of January 2011 and 1st of July 2014. One hundred patients underwent 186 dilatations, with 34 having multiple procedures (mean 1.86). All had oesophageal strictures (mean diameter 8.49 mm, range 5-11 mm) and most underwent dilatation up to a maximum of 17 mm (mean 14.7 mm). Fifty-six percent were male and the average age was 62.5 years (17-89 years). Only one patient (0.5% of all procedures) had a full-thickness perforation requiring intervention while just one further patient had a deep mucosal tear that did not require intervention. TBVD is a safe technique with a short learning curve and is one of the important factors that allow potentially difficult dilatations to be performed safely with an exceptionally low rate of adverse events of less than 1%.

  7. Planetary Science with Balloon-Borne Telescopes

    Science.gov (United States)

    Kremic, Tibor; Cheng, Andy; Hibbitts, Karl; Young, Eliot

    2015-01-01

    The National Aeronautics and Space Administration (NASA) and the planetary science community have recently been exploring the potential contributions of stratospheric balloons to the planetary science field. A study that was recently concluded explored the roughly 200 or so science questions raised in the Planetary Decadal Survey report and found that about 45 of those questions are suited to stratospheric balloon based observations. In September of 2014, a stratospheric balloon mission called BOPPS (which stands for Balloon Observation Platform for Planetary Science) was flown out of Fort Sumner, New Mexico. The mission had two main objectives, first, to observe a number of planetary targets including one or more Oort cloud comets and second, to demonstrate the applicability and performance of the platform, instruments, and subsystems for making scientific measurements in support planetary science objectives. BOPPS carried two science instruments, BIRC and UVVis. BIRC is a cryogenic infrared multispectral imager which can image in the.6-5 m range using an HgCdTe detector. Narrow band filters were used to allow detection of water and CO2 emission features of the observed targets. The UVVis is an imager with the science range of 300 to 600 nm. A main feature of the UVVis instrument is the incorporation of a guide camera and a Fine Steering Mirror (FSM) system to reduce image jitter to less than 100 milliarcseconds. The BIRC instrument was used to image targets including Oort cloud comets Siding Spring and Jacques, and the dwarf planet 1 Ceres. BOPPS achieved the first ever earth based CO2 observation of a comet and the first images of water and CO2 of an Oort cloud comet (Jacques). It also made the first ever measurement of 1Ceres at 2.73 m to refine the shape of the infrared water absorption feature on that body. The UVVis instrument, mounted on its own optics bench, demonstrated the capability for image correction both from atmospheric disturbances as well as some

  8. Intragastric Balloon for Obesity Treatment: Safety, Tolerance, and Efficacy

    Directory of Open Access Journals (Sweden)

    Joana Ribeiro da Silva

    2017-12-01

    Full Text Available Background: Obesity is an increasing worldwide problem associated with a vast number of comorbidities. Decreasing body weight by only 5-10% has been shown to slow and even prevent the onset of obesity-related comorbidities. Between pharmacological therapy and bariatric surgery a great variety of endoscopic techniques are available, the most common being intragastric balloon (IGB. The purpose of this study was to assess the safety, tolerance, and kinetics of IGBs in weight loss. The kinetics of weight loss were evaluated in 2 different contexts and phases: after the IGB's removal and after follow-up that varied between 6 and 12 months. Successful weight loss was defined as ≥10% weight loss after 6-12 months. Methods: The study included 51 patients who had undergone Orbera® IGB placement between September 2014 and February 2016. Inclusion criteria were age between 18 and 65 years; body mass index (BMI 28-35 with severe obesity-related disorders; or BMI 35-40. The IGB was removed 6 months later. All patients were followed for a minimum period of 6-12 months. Results: Of 51 patients, 16 were excluded (7 due to intolerance and 35 patients entered the study, of which 83% were followed for more than 6-12 months. The average weight loss (WL and % excess WL (%EWL after 6 months of treatment were 11.94 kg and 42.16%, respectively. At 6-12 months, after removal of the IGB, the mean WL was 8.25 kg and %EWL was 30.27%. Nineteen patients attained a WL of ≥10% the baseline value at IGB removal and 12 maintained their weight below this threshold during the 6-12 following months. Conclusions: After temporary IGB implantation in overweight or obese individuals, a WL that was ≥10% of weight at baseline was achieved in 54.3% and sustained at 6-12 months in 41.4% of participants. IGBs are an attractive intermediate option between diet and exercise programs and bariatric surgery. In general, IGB placement is a safe and well-tolerated procedure.

  9. Percutaneous endoscopic gastrostomy following previous abdominal surgery.

    Science.gov (United States)

    Stellato, T A; Gauderer, M W; Ponsky, J L

    1984-01-01

    During a 36-month period, 89 patients have undergone percutaneous endoscopic gastrostomy without mortality. Of these patients, 25 (13 infants and children, 12 adults) had prior abdominal procedures that increased their risk for the endoscopic procedure. With two exceptions, all gastrostomies were performed utilizing local anesthesia. There was one major complication, a gastrocolic fistula, which was successfully managed by repeating the endoscopic gastrostomy procedure at a location more cephalad in the stomach. Twenty-two of the gastrostomies were placed for feeding purposes and all of these patients were able to leave the hospital with alimentation accomplished via the tube. Three of the endoscopically placed gastrostomies were for gastrointestinal tract decompression. A total of 255 patient months have been accumulated in these patients with the endoscopically placed gastrostomy in situ. The technique can be safely performed in patients with prior abdominal surgery and in the majority of cases is the technique of choice for establishing a tube gastrostomy. PMID:6428334

  10. Endoscopic palliation in gastric cancer

    International Nuclear Information System (INIS)

    Valdivieso, Eduardo

    2010-01-01

    The integral search for improved living conditions for those patients with gastric cancer who have not received curative surgical treatment continues to challenge the knowledge, dexterity and ethical foundations of medical teams. The justification for palliative treatment must be based on a thorough consideration of the available options and the particular situation in each case. This article reviews endoscopic therapy with auto expandable prosthetics for palliative treatment of gastric cancer, as well as the scientific evidence that supports its use and the factors that determine its indication.

  11. Pneumothorax, music and balloons: A case series

    Directory of Open Access Journals (Sweden)

    Shiferaw Dejene

    2013-01-01

    Full Text Available We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation.

  12. Retrograde transurethral balloon dilation of the prostate

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Wasserman, N.F.; Lund, G.; Hulbert, J.; Hunter, D.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1986-01-01

    A series of patients with documented benign prostatic hypertrophy evaluated by urodynamic studies, voiding cystourethrography, retrograde urethrography, and MR imaging underwent dilation performed using a retrograde transurethral approach with 25-mm balloon dilators inflated at a pressure of 3-4 atm for 10 minutes. Immediately after the procedure, retrograde and voiding cystourethrography as well as MR imaging were performed. A Foley catheter was left in place for 24 hours. Complete relief of symptoms has occurred in all of the patients during the follow-up period. No significant complications other than transient hematuria resulted from the procedure. Results of the comparison studies and of MR imaging are discussed

  13. Resistive G-modes and ballooning

    International Nuclear Information System (INIS)

    Dagazian, R.Y.; Mondt, J.P.; Paris, R.B.

    1980-01-01

    A unified theory of the linear stability of the Roberts and Taylor type of resistive interchange and ballooning is presented. The effects of both parallel and perpendicular viscosity as well as of finite shear and finite β are included in a MHD treatment of the problem. Kinetic effects are also studied. The hybrid kinetic model with Vlasov ions and guiding center electrons has been appropriately generalized to allow for electron-ion collisions. The geometry is that of a plane slab with magnetic shear

  14. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Treatment of massive esophageal variceal bleeding by Sengstaken-Blackmore tube compression and intensive endoscopic detachable mini- loop ligation: a retrospective study in 83 patients.

    Science.gov (United States)

    Zhang, Dingguo; Shi, Ruiyue; Yao, Jun; Zhang, Ru; Xu, Zhenglei; Wang, Lisheng

    2015-01-01

    To evaluate the effectiveness of improved sengstaken-blackmore tube combined with intensive endoscopic detachable mini-loop ligation for the treatment of massive esophageal variceal bleeding (EVB). Eighty-three patients diagnosed with massive EVB and admitted from January 2005 to July 2011 were retrospectively evaluated. Upon admission, all patients received 12 h balloon tamponade with sengstaken-blackmore tube in addition to conventional therapy (blood volume resuscitation, prophylactic antibiotics and somatostatin). Within 24 h after admission, all patients further received endoscopic variceal ligation (EVL) with intensive endoscopic detachable nylon ring (mini-loop). No severe complications were observed after the patients received the 12 h consistent compression with sengstaken-blackmore tube. Eighty-two patients (98.8%) showed effective hemostasis, among which seventy-eight showed complete hemostasis. After receiving the subsequent EVL therapy with intensive endoscopic detachable mini-loop in 24 h after admission, patients did not show active bleeding in 24 h after EVL. Rehaemorrhagia appeared only in one patient within the 7 days of observation period, which was controlled by a second EVL. Each patient was ligated with 10 to 15 loops. EVB can be effectively treated with improved sengstaken-blackmore tube followed by EVL therapy with intensive endoscopic detachable mini-loop.

  16. NOViSE: a virtual natural orifice transluminal endoscopic surgery simulator.

    Science.gov (United States)

    Korzeniowski, Przemyslaw; Barrow, Alastair; Sodergren, Mikael H; Hald, Niels; Bello, Fernando

    2016-12-01

    Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique in minimally invasive surgery whereby a flexible endoscope is inserted via a natural orifice to gain access to the abdominal cavity, leaving no external scars. This innovative use of flexible endoscopy creates many new challenges and is associated with a steep learning curve for clinicians. We developed NOViSE-the first force-feedback-enabled virtual reality simulator for NOTES training supporting a flexible endoscope. The haptic device is custom-built, and the behaviour of the virtual flexible endoscope is based on an established theoretical framework-the Cosserat theory of elastic rods. We present the application of NOViSE to the simulation of a hybrid trans-gastric cholecystectomy procedure. Preliminary results of face, content and construct validation have previously shown that NOViSE delivers the required level of realism for training of endoscopic manipulation skills specific to NOTES. VR simulation of NOTES procedures can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. In the context of an experimental technique, NOViSE could potentially facilitate NOTES development and contribute to its wider use by keeping practitioners up to date with this novel surgical technique. NOViSE is a first prototype, and the initial results indicate that it provides promising foundations for further development.

  17. Clinical and endoscopic risk factors in the Mallory-Weiss syndrome.

    Science.gov (United States)

    Bharucha, A E; Gostout, C J; Balm, R K

    1997-05-01

    Although patients with bleeding Mallory-Weiss tears are generally hospitalized, we wished to develop guidelines facilitating the selection, by clinical and endoscopic criteria, of patients who do not need hospitalization. Our specific aims were to determine whether presenting manifestations of bleeding differed in hemodynamically unstable patients, whether active bleeding or stigmata of bleeding at endoscopy were prognosticators for significant rebleeding, and the outcomes in endoscopically managed patients. The endoscopic and clinical features of all patients with acute GI bleeding from a Mallory-Weiss tear were obtained from our GI Bleeding Team database over a consecutive 4-yr period and analyzed for prognostic indicators. 1) Presenting manifestations, e.g., hematochezia, were significantly different in hypotensive patients. 2) Active bleeding but not stigmata was associated with higher transfusion requirements. 3) Rebleeding was unusual, occurring within 24 h, more often in patients with a bleeding/coagulation diathesis. The median hospital stay was 4 days (range 1-24). Fifty-seven percent of patients received transfusion (median 4 units, range 1-26 units); requirements were higher in patients with coagulopathies. Patients without risk factors for rebleeding (portal hypertension, coagulopathy), clinical features indicating severe bleeding (hematochezia, hemodynamic instability), or active bleeding at endoscopy can be managed with a brief period of observation. Patients with endoscopically active bleeding may benefit from endoscopic therapy.

  18. The Balloon Foot ; A Rare Presentation Of Congenital Constricting ...

    African Journals Online (AJOL)

    We present a case of a rare manifestation of congenital constricting annular band (CAB) in the lower extremity resulting in a severe excessive swelling of the foot which we have termed Balloon foot. The ballooned foot is caused by a progressive deepening of the circumferential constriction into the soft tissue of the lower ...

  19. Scientific ballooning in the 20 th century; a historical perspective

    Science.gov (United States)

    Nishimura, J.

    Hess discovered the cosmic rays in 1912. Using a manned balloon, he found the altitude variation of the radiation. After this discovery, many balloon experiments were performed to explore the most mysterious radiation coming from outside of the earth during the 1920's to the 1930's. At the end of the 1940's, balloon systems were revolutionized by the use of new plastic films and telemetry systems. At almost the same time, highly sensitive nuclear emulsions were developed. Balloon exposures of emulsions brought us new discoveries of the heavy primaries in cosmic rays. Extensive studies with nuclear emulsions discovered high-energy phenomena and new particles between the end of 1940's to the 1960's. At the same time, in various countries, experiments with more sophisticated electronic devices were begun together with ingenious work on balloon technology. Inventions were made in the areas of designing, manufacturing, materials, telemetry systems for balloons and long duration flight systems etc. Several permanent launching stations were established in various countries in the 1960's Here, I review the development of essential technologies in scientific ballooning, and their value in contributing to the growth of space physics. As the future prospect, I stress the point that scientific ballooning is indispensable and a most cost-effective way to explore space astrophysics and Earth science, in addition to the preparation of satellite and the space station experiments.

  20. Coronary artery angioplasty with a helical autoperfusion balloon catheter

    NARCIS (Netherlands)

    Gurbel, PA; Anderson, RD; vanBoven, AJ; denHeijer, P

    The initial in-hospital and long-term clinical experience with a helical autoperfusion balloon catheter in the treatment of coronary artery disease is reported, This new catheter design allows blood to flow passively around the inflated balloon through a protected helical channel molded into the

  1. External caps: An approach to stress reduction in balloons

    Science.gov (United States)

    Hazlewood, K. H.

    Recent findings of the catastrophic balloon failures investigation in the U.S.A. indicate that very large gross inflations, in balloons using present design philosophy, over-stress currently available materials. External caps are proposed as an economic approach to reducting those stresses to an acceptable level.

  2. Natural orifice transluminal endoscopic surgery gastrotomy closure with an over-the-endoscope clip: a randomized, controlled porcine study (with videos).

    Science.gov (United States)

    von Renteln, Daniel; Schmidt, Arthur; Vassiliou, Melina C; Gieselmann, Maria; Caca, Karel

    2009-10-01

    Secure endoscopic closure of transgastric natural orifice transluminal endoscopic surgery (NOTES) access is of paramount importance. The over-the-scope clip (OTSC) system has previously been shown to be effective for NOTES gastrotomy closure. To compare OTSC gastrotomy closure with surgical closure. Randomized, controlled animal study. Animal facility laboratory. Thirty-six female domestic pigs. Gastrotomies were created by using a needle-knife and an 18-mm balloon. The animals were subsequently randomized to either open surgical repair with interrupted sutures or endoscopic repair with 12-mm OTSCs. In addition, pressurized leak tests were performed in ex vivo specimens of 18-mm scalpel incisions closed with suture (n = 14) and of intact stomachs (n = 10). The mean time for endoscopic closure was 9.8 minutes (range 3-22, SD 5.5). No complications occurred during either type of gastrotomy closure. At necropsy, examination of all OTSC and surgical closures demonstrated complete sealing of gastrotomy sites without evidence of injury to adjacent organs. Pressurized leak tests showed a mean burst pressure of 83 mm Hg (range 30-140, SD 27) for OTSC closures and 67 mm Hg (range 30-130, SD 27.7) for surgical sutures. Ex vivo hand-sewn sutures of 18-mm gastrotomies (n = 14) exhibited a mean burst pressure of 65 mm Hg (range 20-140, SD 31) and intact ex vivo stomachs (n = 10) had a mean burst pressure of 126 mm Hg (range 90-170, SD 28). The burst pressure of ex vivo intact stomachs was significantly higher compared with OTSC closures (P < .01), in vivo surgical closures (P < .01), and ex vivo hand-sewn closures (P < .01). There was a trend toward higher burst pressures in the OTSC closures compared with surgical closures (P = .063) and ex vivo hand-sewn closures (P = .094). In vivo surgical closures demonstrated similar burst pressures compared with ex vivo hand-sewn closures (P = .848). Nonsurvival setting. Endoscopic closure by using the OTSC system is comparable to

  3. [Therapeutic aspects of endoscopic polypectomy].

    Science.gov (United States)

    Kratzsch, K H; Stibenz, J; Fürstenau, M; Winkelvoss, H; Büttner, W; Jacobasch, K H; Gütz, H J; Irro, F

    1980-02-15

    466 endoscopic polypectomies of the upper and lower gastrointestinal tract were analysed according to their curative value. In 254 removed polyps of the upper gastrointestinal tract the result of the histological examination was twice a proof of a carcinoma. One it had to be after-resected, once a carcinoid, five times bleeding polyps were removed. Four times prolapsing gastric polyps were removed in the bulbus duodeni. In these cases intermittent disturbances of the passage could be repaired. Thus the endoscopic polypectomy in the upper gastrointestinal tract was of therapeutic value in 4.3%. In the lower intestinal tract in 204 polypectomies 16 focal carcinomas or invasive carcinomas removed in the healthy tissue, 1 carcinoid and 98 bleeding adenomas were cut away. Thus the coloscopic polypectomy was connected with a therapeutic use in 56.3%. 81.8% of the polyps was tubular, papillary or villous adenomas. Taking into consideration the "adenoma-cancer-sequence", the coloscopic polypectomy must thus be regarded as a prophylactic and curative method, while in the polypectomy in the upper gastrointestinal tract the diagnostic value is in the first place.

  4. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.

    1988-01-01

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  5. Spectrum of the ballooning Schroedinger equation

    International Nuclear Information System (INIS)

    Dewar, R.L.

    1997-01-01

    The ballooning Schroedinger equation (BSE) is a model equation for investigating global modes that can, when approximated by a Wentzel-Kramers-Brillouin (WKB) ansatz, be described by a ballooning formalism locally to a field line. This second order differential equation with coefficients periodic in the independent variable θ k is assumed to apply even in cases where simple WKB quantization conditions break down, thus providing an alternative to semiclassical quantization. Also, it provides a test bed for developing more advanced WKB methods: e.g. the apparent discontinuity between quantization formulae for open-quotes trappedclose quotes and open-quotes passingclose quotes modes, whose ray paths have different topologies, is removed by extending the WKB method to include the phenomena of tunnelling and reflection. The BSE is applied to instabilities with shear in the real part of the local frequency, so that the dispersion relation is inherently complex. As the frequency shear is increased, it is found that trapped modes go over to passing modes, reducing the maximum growth rate by averaging over θ k

  6. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  7. Removal of a sewing needle penetrating the wall of the third portion of the duodenum by double-balloon endoscopy.

    Science.gov (United States)

    Shishido, Takayoshi; Oka, Shiro; Tanaka, Shinji; Aoyama, Taiki; Watari, Ikue; Imagawa, Hiroki; Yoshida, Shigeto; Hiyama, Toru; Chayama, Kazuaki

    2012-02-01

    We describe successful removal a sewing needle penetrating the wall of the third portion of the duodenum by means of double-balloon endoscopy (DBE). The patient was a 47-year-old woman who accidentally swallowed a sewing needle and was admitted to our hospital. Abdominal radiography and abdominal computed tomography revealed a metallic object in the third portion of the duodenum. DBE performed by the antegrade approach, revealed that the sewing needle had penetrated the duodenal wall. The sewing needle was retrieved with biopsy forceps and pulled out together with the endoscope through the flexible overtube that remained positioned in the duodenum. There was no injury to the patient's esophagus or gastrointestinal wall. Our experience in this case suggests that sharp foreign bodies in the gastrointestinal tract can be safely removed by means of DBE.

  8. Acute and delayed vesicoureteral obstruction after endoscopic treatment of primary vesicoureteral reflux with dextranomer/hyaluronic acid copolymer: why and how to manage.

    Science.gov (United States)

    García-Aparicio, L; Rodo, J; Palazon, P; Martín, O; Blázquez-Gómez, E; Manzanares, A; García-Smith, N; Bejarano, M; de Haro, I; Ribó, J M

    2013-08-01

    To present our cases of ureteral obstruction after endoscopic treatment of vesicoureteral reflux (VUR) with dextranomer/hyaluronic acid (Dx/HA). We collected data from patients who had suffered ureteral obstruction after endoscopic treatment of VUR with Dx/HA in our institution. From April 2002 to April 2011 we treated endoscopically 475 ureters with VUR, and detected 5 ureteral obstructions. Median age at reflux treatment was 39 months. Reflux grade before treatment was III in one patient and IV in four. Three ureterovesical junctions (UVJ) were blocked after a second endoscopic treatment. The median of Dx/HA injected was 1 ml (0.6-1.1). In two patients ureteral obstruction presented acutely and was treated with a ureteral stent. In the other three, the ureteral obstruction appeared gradually and was detected by ultrasound scans and MAG3 diuretic renogram; one underwent nephrectomy because of poor renal function, and the other two were treated with endoscopic dilatation of the UVJ. In all these patients both reflux and obstructions have resolved. On preoperative cystography, three of the patients had a narrowed distal ureter, and probably had a refluxing and obstructive megaureter. Other causes are not clear, except for those patients with acute presentation in whom edema of the UVJ was found. Ureteral obstruction after endoscopic treatment of VUR is rare. Endoscopic intervention such as ureteral stent placement or high-pressure balloon dilatation of the UVJ has good results as a treatment of acute and delayed obstruction. Copyright © 2013 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  9. Endoscopic management of bleeding peptic ulcers

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Farooqi, R.J.

    2001-01-01

    Peptic ulcers account for more than half of the cases of non variceal upper gastrointestinal (GI) bleeding and therefore, are the focus of most of the methods of endoscopic hemostasis. Surgical intervention is now largely reserved for patients in whom endoscopic hemostasis has failed. A variety of endoscopic techniques have been employed to stop bleeding and reduce the risk of rebleeding, with no major differences in outcome between these methods. These include injection therapy, fibrin injection, heater probe, mono polar electrocautery, bipolar electrocautery, lasers and mechanical hemo clipping. The most important factor in determining outcome after gastrointestinal bleeding is rebleeding or persistent bleeding. The endoscopic appearance of an ulcer, however, provides the most useful prognostic information for bleeding. Recurrent bleeding after initial endoscopic hemostasis occurs in 15-20% of patients with a bleeding peptic ulcer. The best approach to these patients remains controversial; the current options are repeat endoscopic therapy with the same or a different technique, emergency surgery or semi elective surgery after repeat endoscopic hemostasis. The combination of epinephrine injection with thermal coagulation may be more effective than epinephrine injection alone. Newer modalities such as fibrin injection or the application of hemo clips appear promising and comparative studies are awaited. (author)

  10. Arc-Second Pointer for Balloon-Borne Astronomical Instrument

    Science.gov (United States)

    Ward, Philip R.; DeWeese, Keith

    2004-01-01

    A control system has been designed to keep a balloon-borne scientific instrument pointed toward a celestial object within an angular error of the order of an arc second. The design is intended to be adaptable to a large range of instrument payloads. The initial payload to which the design nominally applies is considered to be a telescope, modeled as a simple thin-walled cylinder 24 ft (approx.= 7.3 m) long, 3 ft (approx.= 0.91 m) in diameter, weighing 1,500 lb (having a mass of .680 kg). The instrument would be mounted on a set of motor-driven gimbals in pitch-yaw configuration. The motors on the gimbals would apply the control torques needed for fine adjustments of the instrument in pitch and yaw. The pitch-yaw mount would, in turn, be suspended from a motor mount at the lower end of a pair of cables hanging down from the balloon (see figure). The motor in this mount would be used to effect coarse azimuth control of the pitch-yaw mount. A notable innovation incorporated in the design is a provision for keeping the gimbal bearings in constant motion. This innovation would eliminate the deleterious effects of static friction . something that must be done in order to achieve the desired arc-second precision. Another notable innovation is the use of linear accelerometers to provide feedback that would facilitate the early detection and counteraction of disturbance torques before they could integrate into significant angular-velocity and angular-position errors. The control software processing the sensor data would be capable of distinguishing between translational and rotational accelerations. The output of the accelerometers is combined with that of angular position and angular-velocity sensors into a proportional + integral + derivative + acceleration control law for the pitch and yaw torque motors. Preliminary calculations have shown that with appropriate gains, the power demand of the control system would be low enough to be satisfiable by means of storage

  11. Robotic endoscope motor module and gearing design.

    Science.gov (United States)

    Oliveira, Jillian M; Chen, Yi; Hunter, Ian W

    2011-01-01

    Actuation of a robotic endoscope with increased torque output is presented. This paper will specifically focus on the motor module section of a robotic endoscope, which comprises of a pair of motors and gear reduction assemblies. The results for the endoscope and biopsy tool stiffness, as well as the stall force and force versus speed characteristics of the motor module assembly are shown. The scope stiffness was found to be 0.006 N/degree and additional stiffness of the biopsy tools were found to be in the range of 0.09 to 0.13 N/degree. Calculations for worm gearing and efficiency are discussed.

  12. [PACS-based endoscope image acquisition workstation].

    Science.gov (United States)

    Liu, J B; Zhuang, T G

    2001-01-01

    A practical PACS-based Endoscope Image Acquisition Workstation is here introduced. By a Multimedia Video Card, the endoscope video is digitized and captured dynamically or statically into computer. This workstation realizes a variety of functions such as the endoscope video's acquisition and display, as well as the editing, processing, managing, storage, printing, communication of related information. Together with other medical image workstation, it can make up the image sources of PACS for hospitals. In addition, it can also act as an independent endoscopy diagnostic system.

  13. Detecting Seismic Infrasound Signals on Balloon Platforms

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M.; Garcia, R.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-12-01

    The determination of the interior structure of a planet requires detailed seismic investigations - a process that entails the detection and characterization of seismic waves due to geological activities (e.g., earthquakes, volcanoes, etc.). For decades, this task has primarily been performed on Earth by an ever-expanding network of terrestrial seismic stations. However, on planets such as Venus, where the surface pressure and temperature can reach as high as 90 atmospheres and 450 degrees Celsius respectively, placing seismometers on the planet's surface poses a vexing technological challenge. However, the upper layers of the Venusian atmosphere are more benign and capable of hosting geophysical payloads for longer mission lifetimes. In order to achieve the aim of performing geophysical experiments from an atmospheric platform, JPL and its partners (ISAE-SUPAERO and California Institute of Technology) are in the process of developing technologies for detection of infrasonic waves generated by earthquakes from a balloon. The coupling of seismic energy into the atmosphere critically depends on the density differential between the surface of the planet and the atmosphere. Therefore, the successful demonstration of this technique on Earth would provide ample reason to expect success on Venus, where the atmospheric impedance is approximately 60 times that of Earth. In this presentation, we will share results from the first set of Earth-based balloon experiments performed in Pahrump, Nevada in June 2017. These tests involved the generation of artificial sources of known intensity using a seismic hammer and their detection using a complex network of sensors, including highly sensitive micro-barometers suspended from balloons, GPS receivers, geophones, microphones, and seismometers. This experiment was the first of its kind and was successful in detecting infrasonic waves from the earthquakes generated by the seismic hammer. We will present the first comprehensive analysis

  14. Microcontroller uses in Long-Duration Ballooning

    Science.gov (United States)

    Jones, Joseph

    This paper discusses how microcontrollers are being utilized to fulfill the demands of long duration ballooning (LDB) and the advantages of doing so. The Columbia Scientific Balloon Facility (CSBF) offers the service of launching high altitude balloons (120k ft) which provide an over the horizon telemetry system and platform for scientific research payloads to collect data. CSBF has utilized microcontrollers to address multiple tasks and functions which were previously performed by more complex systems. A microcontroller system has been recently developed and programmed in house to replace our previous backup navigation system which is used on all LDB flights. A similar microcontroller system was developed to be independently launched in Antarctica before the actual scientific payload. This system's function is to transmit its GPS position and a small housekeeping packet so that we can confirm the upper level float winds are as predicted from satellite derived models. Microcontrollers have also been used to create test equipment to functionally check out the flight hardware used in our telemetry systems. One test system which was developed can be used to quickly determine if our communication link we are providing for the science payloads is functioning properly. Another system was developed to provide us with the ability to easily determine the status of one of our over the horizon communication links through a closed loop system. This test system has given us the capability to provide more field support to science groups than we were able to in years past. The trend of utilizing microcontrollers has taken place for a number of reasons. By using microcontrollers to fill these needs, it has given us the ability to quickly design and implement systems which meet flight critical needs, as well as perform many of the everyday tasks in LDB. This route has also allowed us to reduce the amount of time required for personnel to perform a number of the tasks required

  15. Management of Nodular Neoplasia in Barrett's Esophagus: Endoscopic Mucosal Resection and Endoscopic Submucosal Dissection.

    Science.gov (United States)

    Belghazi, Kamar; Bergman, Jacques J G H M; Pouw, Roos E

    2017-07-01

    Endoscopic resection has proven highly effective and safe in the removal of focal early neoplastic lesions in Barrett's esophagus and is considered the cornerstone of endoscopic treatment. Several techniques are available for endoscopic resection in Barrett's esophagus. The most widely used technique for piecemeal resection of early Barrett's neoplasia is the ligate-and-cut technique. Newer techniques such as endoscopic submucosal dissection may also play a role in the treatment of neoplastic Barrett's esophagus. Treatment of early Barrett's neoplasia should be centralized and limited to expert centers with a high-volume load and sufficient expertise in the detection and treatment of esophageal neoplasia. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Rectal Balloon for the Immobilization of the Prostate Internal Motion

    International Nuclear Information System (INIS)

    Lee, Sang Kyu; Beak, Jong Geal; Kim, Joo Ho; Jeon, Byong Chul; Cho, Jeong Hee; Kim, Dong Wook; Song, Tae Soo; Cho, Jae Ho; Na, Soo Kyong

    2005-01-01

    The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning same repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal balloon position and verified the isodose distribution of rectum wall at closed prostate. Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficient for treated prostate cancer patients.

  17. Graph-Based Path-Planning for Titan Balloons

    Science.gov (United States)

    Blackmore, Lars James; Fathpour, Nanaz; Elfes, Alberto

    2010-01-01

    A document describes a graph-based path-planning algorithm for balloons with vertical control authority and little or no horizontal control authority. The balloons are designed to explore celestial bodies with atmospheres, such as Titan, a moon of Saturn. The algorithm discussed enables the balloon to achieve horizontal motion using the local horizontal winds. The approach is novel because it enables the balloons to use arbitrary wind field models. This is in contrast to prior approaches that used highly simplified wind field models, such as linear, or binary, winds. This new approach works by discretizing the space in which the balloon operates, and representing the possible states of the balloon as a graph whose arcs represent the time taken to move from one node to another. The approach works with arbitrary wind fields, by looking up the wind strength and direction at every node in the graph from an arbitrary wind model. Having generated the graph, search techniques such as Dijkstra s algorithm are then used to find the set of vertical actuation commands that takes the balloon from the start to the goal in minimum time. In addition, the set of reachable locations on the moon or planet can be determined.

  18. A Survey of Titan Balloon Concepts and Technology Status

    Science.gov (United States)

    Hall, Jeffery L.

    2011-01-01

    This paper surveys the options for, and technology status of, balloon vehicles to explore Saturn's moon Titan. A significant amount of Titan balloon concept thinking and technology development has been performed in recent years, particularly following the spectacular results from the descent and landing of the Huygens probe and remote sensing observations by the Cassini spacecraft. There is widespread recognition that a balloon vehicle on the next Titan mission could provide an outstanding and unmatched capability for in situ exploration on a global scale. The rich variety of revealed science targets has combined with a highly favorable Titan flight environment to yield a wide diversity of proposed balloon concepts. The paper presents a conceptual framework for thinking about balloon vehicle design choices and uses it to analyze various Titan options. The result is a list of recommended Titan balloon vehicle concepts that could perform a variety of science missions, along with their projected performance metrics. Recent technology developments for these balloon concepts are discussed to provide context for an assessment of outstanding risk areas and technological maturity. The paper concludes with suggestions for technology investments needed to achieve flight readiness.

  19. Ballooning modes or Fourier modes in a toroidal plasma?

    International Nuclear Information System (INIS)

    Connor, J.W.; Taylor, J.B.

    1987-01-01

    The relationship between two different descriptions of eigenmodes in a torus is investigated. In one the eigenmodes are similar to Fourier modes in a cylinder and are highly localized near a particular rational surface. In the other they are the so-called ballooning modes that extend over many rational surfaces. Using a model that represents both drift waves and resistive interchanges the transition from one of these structures to the other is investigated. In this simplified model the transition depends on a single parameter which embodies the competition between toroidal coupling of Fourier modes (which enhances ballooning) and variation in frequency of Fourier modes from one rational surface to another (which diminishes ballooning). As the coupling is increased each Fourier mode acquires a sideband on an adjacent rational surface and these sidebands then expand across the radius to form the extended mode described by the conventional ballooning mode approximation. This analysis shows that the ballooning approximation is appropriate for drift waves in a tokamak but not for resistive interchanges in a pinch. In the latter the conventional ballooning effect is negligible but they may nevertheless show a ballooning feature. This is localized near the same rational surface as the primary Fourier mode and so does not lead to a radially extended structure

  20. N-dependence of ballooning instabilities

    International Nuclear Information System (INIS)

    Dewar, R.L.; Manickam, J.; Grimm, R.C.; Chance, M.S.

    1980-05-01

    The critical β for stability against ideal hydromagnetic internal ballooning modes as a function of toroidal mode number, n, is calculated for two different equilibrium sequences by use of a finite element technique (n less than or equal to 20), and a WKB formalism (n greater than or equal to 5). The agreement between the two methods is good in the overlap region 5 approx.less than or equal to n approx. less than or equal to 20. The WKB formula reduces to the 1/n correction at very high n, but is much more accurate at moderate n. The critical β vs n curves exhibit oscillatory structure at low n, but in both sequences the lower bound on β/sub c/ approx. 5%. For reactor parameters, finite Larmor radius effects are not expected to have a large effect on this β-limitation

  1. Management of intra-aortic balloon pumps.

    Science.gov (United States)

    Webb, Christopher A-J; Weyker, Paul D; Flynn, Brigid C

    2015-06-01

    Intra-aortic balloon pumps (IABPs) continue to be the most widely used cardiac support devices with an annual estimate of 200 000 IABPs placed worldwide. IABPs enhance myocardial function by maximizing oxygen supply and minimizing oxygen demand. The use of IABPs is not without risk, with major vascular injury, ischemia, and infection being the most common complications, especially in high-risk patients. While recent studies have questioned the use of IABPs in patients with cardiogenic shock secondary to myocardial infarction, these studies have limitations making it difficult to formulate definitive conclusions. This review will focus on the mechanisms of counterpulsation, the management of IABPs and the evidence supporting this ventricular support therapy. © The Author(s) 2014.

  2. High Energy Antimatter Telescope (HEAT) Balloon Experiment

    Science.gov (United States)

    Beatty, J. J.

    1995-01-01

    This grant supported our work on the High Energy Antimatter Telescope(HEAT) balloon experiment. The HEAT payload is designed to perform a series of experiments focusing on the cosmic ray positron, electron, and antiprotons. Thus far two flights of the HEAT -e+/- configuration have taken place. During the period of this grant major accomplishments included the following: (1) Publication of the first results of the 1994 HEAT-e+/- flight in Physical Review Letters; (2) Successful reflight of the HEAT-e+/- payload from Lynn Lake in August 1995; (3) Repair and refurbishment of the elements of the HEAT payload damaged during the landing following the 1995 flight; and (4) Upgrade of the ground support equipment for future flights of the HEAT payload.

  3. Endoscopic-assisted treatment of trigonocephaly.

    Science.gov (United States)

    Hinojosa, J

    2012-09-01

    Minimally invasive, endoscopic repair of metopic craniosynostosis has emerged as a potentially efficacious, safe, and aesthetically acceptable alternative to open procedures. Potential advantages of an early endoscopic approach to repair metopic craniosynostosis include a reduction in blood loss and consequent decreases in transfusion volumes, decreased hospital costs, shorter operative times, and limited duration of hospitalization. Other benefits of minimally invasive techniques would be avoidance of anaesthetic surgical scarring, decrease in postoperative swelling and discomfort, and lower rate of complications such as duramater tears, postoperative hyperthermia, or infection. However, a concern is usually raised about the achievements of the "endoscopic" techniques when compared to "standard" open approaches. The indications for endoscopic-assisted surgery in the treatment of trigonocephaly remain controversial and further series and follow-up of these patients are necessary to set up the role of these approaches.

  4. Cholangiography and endoscopic sphincterotomy in the ...

    African Journals Online (AJOL)

    Cholangiography and endoscopic sphincterotomy in the management of severe acute gallstone pancreatitis discovered at diag~osticlaparotomy. ... in these cases Included cholecystectomy and Ttube drainage (2 patients) cholecystostomy drainage (3 patients), and closure of the abdomen without drainage (2 patients).

  5. Endoscopic appearance of irradiated gastric mucosa

    Energy Technology Data Exchange (ETDEWEB)

    De Sagher, L.I.; Van den Heule, B.; Van Houtte, P.; Engelholm, L.; Balikdjan, D.; Bleiberg, H.

    1979-09-01

    Irradiation of the epigastric area for gastric cancer may induce actinic lesions of the stomach characterized on endoscopic examination by ulcerations, haemorrhagic gastritis, fragility of the mucosa, thickening and congestion of the gastric folds.

  6. Vagal withdrawal during endoscopic retrograde cholangiopancreatography

    DEFF Research Database (Denmark)

    Christensen, M; Rasmussen, Verner; Schulze, S

    2000-01-01

    BACKGROUND: Patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) are at risk of developing cardiorespiratory complications, but the mechanism is still unknown. Treatment with metoprolol 2 h before the endoscopy has been shown to decrease the incidence of myocardial ischaemia...

  7. Diagnosis and management of iatrogenic endoscopic perforations

    DEFF Research Database (Denmark)

    Paspatis, Gregorios A; Dumonceau, Jean-Marc; Barthet, Marc

    2014-01-01

    center implements a written policy regarding the management of iatrogenic perforation, including the definition of procedures that carry a high risk of this complication. This policy should be shared with the radiologists and surgeons at each center. 2 In the case of an endoscopically identified......This Position Paper is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the diagnosis and management of iatrogenic perforation occurring during diagnostic or therapeutic digestive endoscopic procedures. Main recommendations 1 ESGE recommends that each...... management should be based on the estimated success of the endoscopic closure and on the general clinical condition of the patient. In the case of no or failed endoscopic closure of the iatrogenic perforation, and in patients whose clinical condition is deteriorating, hospitalization and surgical...

  8. Defining the Limits of Endoscopic Access to Internal Auditory Canal.

    Science.gov (United States)

    Master, Adam; Hamiter, Mickie; Cosetti, Maura

    2016-12-01

    To quantify surgical access to the internal auditory canal (IAC) using an exclusively endoscopic transcanal approach (EETA) and investigate surgically relevant relationships with neurovascular and osseous landmarks of the temporal bone. Anatomical dissection of two paired temporal bones and 15 unpaired temporal bones was performed using an exclusively endoscopic approach to IAC. The dissection proceeded until the cerebellopontine angle (CPA) could be accessed. Following dissection, all the specimens were subjected to computed tomography (CT) imaging. Anatomage InVivo5 software was used to analyze the CT scans and record measurements. CPA access and visualization of the labyrinthine segment of the facial nerve were achieved in all specimens. The mean distances from the carotid artery, jugular bulb, and middle fossa to the surgical opening (or fundostomy) of IAC were 4.1±1.5, 6.4±2.5, and 5.5±1.9 mm, respectively. The mean cross-sectional areas of the fundostomy and tympanic ring were 30.8±10.4 and 67.7±11.3 mm2. The mean distances from the osteo-cartilaginous junction and tympanic ring to the porus acusticus were 29±2.6 and 21±2.3 mm, respectively. Transcanal access to the entire IAC can be safely achieved using an exclusively endoscopic approach. Generous removal of the cochlear promontory can be accomplished while a safe distance is maintained from key neurovascular structures. EETA to IAC offers a minimally invasive alternative to patients without serviceable hearing for intrameatal and medial IAC tumors. Increased knowledge of crucial anatomical relationships involved in this approach will facilitate acceptance and utilization.

  9. Role of endoscopic retrograde cholangiopancreatography before and after laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Sbeih, F.; Aljohani, M.; Altraif, I.; Khan, H.

    1998-01-01

    While the role of endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (EST) in the diagnosis and management of choledocholithiasis is well established, this study evaluates the usefulness of ERCP and EST patients with symptomatic cholecystolithiasis and suspected choledocholithiasis before undergoing laparoscopic cholecystectomy (LC), and the role of ERCP-EST in the management of complications resulting from LC. This paper reviews retrospectively our experience from 1992 to 1995. A total of 1221 LCs and 717 ERCPs were performed on 225 patients who underwent LC (230 ERCPs before and 27 after). The age range was 10-85 years (mean 43.5. The study group comprised 148 (66%) females and 77 males (34%). The overall success rate for ERCP was 92% (96% for diagnostic and 88% for therapeutic). Choledocholithiasis was found at preoperative ERCP in 45% cases. Prediction of cholecoledocholithiasis was accurate in 46%, based on abnormal liver chemistry, and 70% when based on a combination of abnormal liver tests and dilated main bile duct (>7 mm) by ultrasound. In 40 cases of acute biliary pancreatitis, choledocholithiasis was found at ERCP in eight cases (20%). In the post LC-group, all eight cases with residual stones and seven of eight cases with bile leaks were successfully treated endoscopically. There were four cases with major duct injuries that required surgical management. The complications related to ERCP-EST included two cases of bleeding post-EST (one was controlled with injection therapy and the second one was managed surgically) and three cases of mild pancreatitis. ERCP and EST are effective and safe in the diagnosis and management of choledocholithiasis and facilitate LC for symptomatic cholelithiasis. The procedures are also valuable in the diagnosis and management of most complications resulting from LC. (author)

  10. Duodenal endoscopic full-thickness resection (with video).

    Science.gov (United States)

    Schmidt, Arthur; Meier, Benjamin; Cahyadi, Oscar; Caca, Karel

    2015-10-01

    Endoscopic resection of duodenal non-lifting adenomas and subepithelial tumors is challenging and harbors a significant risk of adverse events. We report on a novel technique for duodenal endoscopic full-thickness resection (EFTR) by using an over-the-scope device. Data of 4 consecutive patients who underwent duodenal EFTR were analyzed retrospectively. Main outcome measures were technical success, R0 resection, histologic confirmation of full-thickness resection, and adverse events. Resections were done with a novel, over-the-scope device (full-thickness resection device, FTRD). Four patients (median age 60 years) with non-lifting adenomas (2 patients) or subepithelial tumors (2 patients) underwent EFTR in the duodenum. All lesions could be resected successfully. Mean procedure time was 67.5 minutes (range 50-85 minutes). Minor bleeding was observed in 2 cases; blood transfusions were not required. There was no immediate or delayed perforation. Mean diameter of the resection specimen was 28.3 mm (range 22-40 mm). Histology confirmed complete (R0) full-thickness resection in 3 of 4 cases. To date, 2-month endoscopic follow-up has been obtained in 3 patients. In all cases, the over-the-scope clip was still in place and could be removed without adverse events; recurrences were not observed. EFTR in the duodenum with the FTRD is a promising technique that has the potential to spare surgical resections. Modifications of the device should be made to facilitate introduction by mouth. Prospective studies are needed to further evaluate efficacy and safety for duodenal resections. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. The MIPAS balloon borne trace constitutent experiment

    Science.gov (United States)

    Oelhaf, H.; Vonclarmann, TH.; Fischer, H.; Friedl-Vallon, F.; Fritzsche, CHR.; Piesch, CHR.; Rabus, D.; Seefeldner, M.; Voelker, W.

    1994-01-01

    A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

  12. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    Pretolesi, F.; Derchi, L.E.; Redaelli, G.; Papagni, L.

    2001-01-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  13. An investigation of electrostatically deposited radionuclides on latex balloons

    International Nuclear Information System (INIS)

    Price, T.; Caly, A.

    2012-01-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  14. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  15. New Heights with High-Altitude Balloon Launches for Effective Student Learning and Environmental Awareness

    Science.gov (United States)

    Voss, H. D.; Dailey, J. F.; Takehara, D.; Krueger, J. M.

    2009-12-01

    Over a seven-year period Taylor University, an undergraduate liberal art school, has successfully launched and recovered over 200 sophisticated student payloads to altitudes between 20-33 km (100% success with rapid recovery) with flight times between 2 to 6 hrs. All of the payloads included two GPS tracking systems, cameras and monitors, a 110 kbit down link, an uplink command capability for educational experiments (K-12 and undergrad). Launches were conducted during the day and night, with multiple balloons, with up to 10 payloads for experiments, and under varying weather and upper atmospheric conditions. The many launches in a short period of time allowed the payload bus design to evolve toward increased performance, reliability, standardization, simplicity, and modularity for low-cost launch services. Through NSF and NASA grants, the program has expanded leading to over 50 universities trained at workshops to implement high altitude balloon launches in the classroom. A spin-off company (StraoStar Systems LLC) now sells the high-altitude balloon system and facilitates networking between schools. This high-altitude balloon program helps to advance knowledge and understanding across disciplines by giving students and faculty rapid and low-cost access to earth/ecology remote sensing from high altitude, insitu and limb atmospheric measurements, near-space stratosphere measurements, and IR/UV/cosmic ray access to the heavens. This new capability is possible by exposing students to recent advances in MEMS technology, nanotechnology, wireless telecommunication systems, GPS, DSPs and other microchip miniaturizations to build climate change and ways to mitigate global warming, and the excitement of taking measurements in a much uncharted region of our atmosphere. Teaching the scientific method or learning cycle (theory, research, instrumentation, operations, data analysis, and presentation) is a significant pedagogical building block that stimulates and retains students

  16. TV endoscope system for composite clinical application

    International Nuclear Information System (INIS)

    Endo, Noriaki; Shimura, Yasushi

    1994-01-01

    Toshiba developed a third-generation TV endoscope system in 1992, model TRE-3000, featuring high image quality. The concept of 'pursuit of a system for composite clinical application' was fully taken into account in the development of the system. This paper describes the new system, which has the capability to display both endoscopic images and X-ray images on the same TV monitor. (author)

  17. An unusual experience with endoscopic retrograde cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Mallikarjun Patil

    2013-01-01

    Full Text Available The endoscopic retrograde cholangiopancreatography (ERCP is known for its varied diagnostic and therapeutic utility for a variety of disorders. However it has greater likelihood of procedure related complications among the endoscopic procedures of gastrointestinal tract. The extraluminal hemorrhagic complications following ERCP are potentially life threatening though relatively rare. We present a 50 year patient with choledocholithiasis and cholelithiasis developing rare complication of subcapsular hepatic hematoma, following ERCP due to guide wire injury.

  18. Robotics and systems technology for advanced endoscopic procedures: experiences in general surgery.

    Science.gov (United States)

    Schurr, M O; Arezzo, A; Buess, G F

    1999-11-01

    The advent of endoscopic techniques changed surgery in many regards. This paper intends to describe an overview about technologies to facilitate endoscopic surgery. The systems described have been developed for the use in general surgery, but an easy application also in the field of cardiac surgery seems realistic. The introduction of system technology and robotic technology enables today to design a highly ergonomic solo-surgery platform. To relief the surgeon from fatigue we developed a new chair dedicated to the functional needs of endoscopic surgery. The foot pedals for high frequency, suction and irrigation are integrated into the basis of the chair. The chair is driven by electric motors controlled with an additional foot pedal joystick to achieve the desired position in the OR. A major enhancement for endoscopic technology is the introduction of robotic technology to design assisting devices for solo-surgery and manipulators for microsurgical instrumentation. A further step in the employment of robotic technology is the design of 'master-slave manipulators' to provide the surgeon with additional degrees of freedom of instrumentation. In 1996 a first prototype of an endoscopic manipulator system. named ARTEMIS, could be used in experimental applications. The system consists of a user station (master) and an instrument station (slave). The surgeon sits at a console which integrates endoscopic monitors, communication facilities and two master devices to control the two slave arms which are mounted to the operating table. Clinical use of the system, however, will require further development in the area of slave mechanics and the control system. Finally the implementation of telecommunication technology in combination with robotic instruments will open new frontiers, such as teleconsulting, teleassistance and telemanipulation.

  19. Gastric outlet obstruction: An unusual adverse event of percutaneous endoscopic gastrostomy.

    Science.gov (United States)

    Barosa, Rita; Santos, Carla; Fonseca, Jorge

    2016-01-01

    Dear Editor, A 75-year-old woman living in a nursing home presented with a 24-hour history of abdominal cramping and vomiting. Medical history was remarkable for dementia and a percutaneous endoscopic gastrostomy (PEG) was performed 3 years earlier. The day before the admission the feeding tube was accidentally pulled out and a Foley catheter was placed in order to avoid stoma closure. On physical examination, there was extravasation of the gastric content through the stoma. The base of the "Y" of the Foley catheter was introduced in the gastric stoma and a pulling sensation was felt when it was mobilized. The remainder abdominal examination was unremarkable. On esophagogastroduodenoscopy the Foley catheter was identified passing the pylorus and pulling duodenal bulb towards the antrum (Figure 1). Advancing the scope through the duodenum, the Foley balloon impacted in the duodenal apex was identified. There was no mucosal injury so the balloon was deflated and the catheter removed. A 14 Fr. Bard PEG tube was latter placed to allow a reduction in the calibre of the stoma. Gastric outlet obstruction is an unusual adverse event of PEG tubes. In adults it is usually related to Foley catheters use as peristalsis can pull the balloon into the duodenum in the absence of an external bumper. A clinical picture of abdominal cramping, vomiting and resistance to the attempt of percutaneous reposition should raise the suspicion of gastrostomy tube migration through the pylorus. Foley catheters are easily available and some may use it to prevent gastrostomy closure after accidentally PEG tube extraction. We have performed more than 800 PEG and assisted several cases of gastric outlet obstruction and even stoma damage in this setting. This case emphasises the importance of receiving an early PEG tube with external bumper replacement to prevent this adverse event.

  20. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  1. Management of duodenal-jejunal polyps in children with peutz-jeghers syndrome with single-balloon enteroscopy.

    Science.gov (United States)

    Bizzarri, Barbara; Borrelli, Osvaldo; de'Angelis, Nicola; Ghiselli, Alessia; Nervi, Giorgio; Manfredi, Marco; de'Angelis, Gian Luigi

    2014-07-01

    Children with Peutz-Jeghers syndrome (PJS) have increased risk of polyp-related complications and emergency laparotomies. The aim of the present study was to assess the efficacy and the safety of endoscopic therapy of small bowel polyps using single-balloon enteroscopy (SBE) in children affected by PJS. Between January 2010 and December 2011, prospectively consecutive PJS children with polyps >15 mm or polyps actively bleeding previously identified using video capsule endoscopy and magnetic resonance imaging underwent therapeutic SBE. The main outcome measurements were the feasibility, the technical performance, and the safety. A total of 10 children (6 boys; median age 13.7 years, range 5.6-15.6) underwent 23 SBE procedures. Four patients had a history of abdominal surgery. A total of 53 polyps were removed, and 23 of them were >15 mm. The majority of polyps were found in jejunum (85%). The mean insertion depths for antegrade and retrograde approach were 200 ± 80 and 100 ± 50 cm beyond the ileal valve, respectively. The mean procedure time was 75 ± 25 minutes. Mild abdominal pain was reported after 3 procedures. In 1 patient a postpolypectomy perforation occurred. In conclusion, SBE is an effective endoscopic tool for treating small bowel polyps in children with PJS, and well-timed polypectomy may optimize patients' care, preventing polyp-related complications and emergency laparotomy. Further larger multicenter studies are warranted to accurately determine the safety of therapeutic SBE in children.

  2. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    , and supervised performance on patients. Each step should be completed by passing a validated exam before proceeding to the next step. This approach will assure basic competency on all levels, and testing also facilitates learning and improves retention. Competence in endosonography can be based on a systematic......The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators...

  3. Solitary rectal ulcer syndrome: clinical, endoscopic, histological and anorectal manometry findings in north Indian patients.

    Science.gov (United States)

    Behera, M K; Dixit, V K; Shukla, S K; Ghosh, J K; Abhilash, V B; Asati, P K; Jain, A K

    2015-01-01

    Solitary rectal ulcer syndrome (SRUS) is a chronic, benign defecation disorder often related to excessive straining. SRUS is diagnosed on the basis of clinical symptoms, endoscopic and histological findings. All patients diagnosed with SRUS by colonoscopy and confirmed by histopathology from October 2012 to August 2014 in the Department of Gastroenterology, Institute of Medical Sciences, Banaras Hindu University, India, were included in the study. Out of 92 patients, thirty-four patients underwent anorectal manometry. Twenty age-matched healthy volunteers were also studied with anorectal manometry to serve as controls. Mean age of the group was 41 ± 19 years with age range of 10-82 years; males were 58 (63%) with male to female ratio of 1.7:1. Bleeding per rectum was present in 83%, constipation in 46.7%, abdominal pain in 27.2%, and diarrhea in 25% of the patients. On endoscopy, ulcerative lesions were seen in 83% patients of whom solitary and multiple lesions were present in 44% and 39%, respectively. Polypoidal lesions were reported in 17.4% whilst rectal polyps and erythematous mucosa were found in 5.4% and 2.2%, respectively. Histological examination revealed fibromuscular obliteration in 100% of patients, surface ulceration in 70.6% and crypt distortion in 20.65% of patients. Anal relaxation and balloon expulsion test was significantly abnormal in SRUS patients compared to healthy controls (53% vs. 20%, p ulcerative lesions the most common endoscopic finding. Fecal evaluation disorder was more prevalent inpatients with SRUS.

  4. Endoscopic approach for a laryngeal neoplasm in a dog

    Directory of Open Access Journals (Sweden)

    Pedro Paulo Maia Teixeira

    2015-01-01

    Full Text Available Laryngeal and tracheal tumors are rare in pets; some piece of information on their disease behavior, therapy and evolution are limited. Neoplasms in this area are a diagnostic challenge. In many cases, they can be biopsied and excised using endoscopic instruments, but there is no report of this in canines. The goal of this study is to report a successful case of a laryngeal neoplasm removal through endoscopy. A head and neck radiogram revealed a mass in the laryngeal lumen protruding into the trachea. The patient then underwent an endoscopy to confirm the radiographic diagnosis and to surgically remove the tumor. The histopathological diagnosis was poorly differentiated carcinoma. The most appropriate treatment for laryngeal tumors is the resection of the submucosa or a partial laryngectomy however, partial and total laryngectomies are associated with many postoperative complications. In contrast, the endoscopic approach allows for highly magnified visualization of the lesion in situ, which facilitates the surgical removal of the mass through videosurgery. With little manipulation of the affected area, the chances of postoperative complications are reduced, leading to a more rapid recovery.

  5. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Science.gov (United States)

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Role of endoscopic ultrasound and endoscopic resection for the treatment of gastric schwannoma.

    Science.gov (United States)

    Hu, Jinlong; Liu, Xiang; Ge, Nan; Wang, Sheng; Guo, Jintao; Wang, Guoxin; Sun, Siyu

    2017-06-01

    Endoscopic ultrasound (EUS) and endoscopic resection play an important role in gastric submucosal tumor. However, there were few articles regarding EUS and endoscopic resection of gastric schwannomas. Our aim was to evaluate the role of EUS and endoscopic resection in treating gastric schwannomas.We retrospectively reviewed 14 patients between March 2012 and April 2016 with gastric schwannomas and who received EUS and endoscopic resection. EUS characteristics, endoscopic resection, tumor features, and follow-up were evaluated in all the patients.Fourteen patients were enrolled in the present study. The patients' ages ranged from 25 to 72 years (mean age, 52.6 years). On EUS, all tumors were originating from muscularis propria and hypoechoic. Ten tumors have the extraluminal growth patterns and 4 tumors have the intraluminal growth patterns. Marginal halos were observed in 7 lesions. No cystic change and calcification were found inside the lesions. Complete endoscopic resection was performed in all the patients with no complications occurring in any patients. No recurrence or metastases was found in all patients during the follow-up period.Gastric schwannoma has some characteristics on EUS, but it is difficult to differentiate gastric schwannoma from gastrointestinal stromal tumor. Endoscopic resection is an effective and safe treatment for gastric schwannoma with an excellent follow-up outcome.

  7. OCT evaluation of directional atherectomy compared to balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Marmagkiolis, Konstantinos [Citizens Memorial Hospital Heart and Vascular Institute, Bolivar, MO (United States); Lendel, Vasili [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2015-09-15

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. - Highlights: • Directional atherectomy avoids the vascular mechanical damage caused by angioplasty balloons and the exposure of stent struts or the potential of stent fracture with stents. • OCT can accurately assess the effect of endovacular interventions to the vessel wall. • Although angiographic results after directional atherectomy are acceptable, OCT use demonstrated suboptimal improvement of the MLA requiring additional balloon angioplasty. • Longer studies are needed to define whether the improved OCT results with angioplasty compared to DA may offer better clinical outcomes.

  8. Remote sensing and sensor testing via hot air balloons

    Energy Technology Data Exchange (ETDEWEB)

    Watson, S.M. [Univ. of Utah, Salt Lake City, UT (United States); Kroutil, R.T. [Army Edgewood Research, Development and Engineering Center, Aberdeen Proving Ground, MD (United States); Traynor, C.A. [DARPA High Performance Computing Applications, Arlington, VA (United States)] [and others

    1996-11-01

    Tethered and free-flying manned hot air balloons have been demonstrated as platforms for various remote sensing asks and sensor testing and atmospheric measurements. These platforms are inexpensive to operate, do not cause atmospheric disturbances as do higher speed platforms, and are extremely stable and free of vibrations inherent in aircraft structures. The equipment operated and tested on the balloons in connection with this project includes a prototype multispectral imaging spectrometer, high resolution CCD cameras, mid- and far-infrared cameras, a radiometer, FTIR spectrometers, video recording equipment and portable power generators carried beneath the balloon providing power to the equipment The experiments conducted on and from the balloon include chemical effluents characterization, atmospheric propagation through slant paths, obscurants imaging and scene reflectance. 7 refs.

  9. Development of Venus Balloon Seismology Missions Through Earth Analog Experiments

    Science.gov (United States)

    Krishnamoorthy, S.; Komjathy, A.; Cutts, J. A.; Pauken, M. T.; Garcia, R. F.; Mimoun, D.; Jackson, J. M.; Kedar, S.; Smrekar, S. E.; Hall, J. L.

    2017-11-01

    The study of a planet’s seismic activity is central to the understanding of its internal structure. We discuss advances made through Earth analog testing for performing remote seismology on Venus using balloons floated in the mid-atmosphere.

  10. Stabilization of ballooning modes with sheared toroidal rotation

    International Nuclear Information System (INIS)

    Miller, R.L.; Waelbroeck, F.L.; Hassam, A.B.; Waltz, R.E.

    1995-01-01

    Stabilization of magnetohydrodynamic ballooning modes by sheared toroidal rotation is demonstrated using a shifted circle equilibrium model. A generalized ballooning mode representation is used to eliminate the fast Alfven wave, and an initial value code solves the resulting equations. The s-α diagram (magnetic shear versus pressure gradient) of ballooning mode theory is extended to include rotational shear. In the ballooning representation, the modes shift periodically along the field line to the next point of unfavorable curvature. The shift frequency (dΩ/dq, where Ω is the angular toroidal velocity and q is the safety factor) is proportional to the rotation shear and inversely proportional to the magnetic shear. Stability improves with increasing shift frequency and direct stable access to the second stability regime occurs when this frequency is approximately one-quarter to one-half the Alfven frequency, ω A =V A /qR. copyright 1995 American Institute of Physics

  11. SMEX02 Balloon-borne Radiosonde Data, Iowa, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes radiosonde measurements of upper air temperature and pressure, relative humidity, and wind direction and speed during the balloons' ascent to...

  12. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  13. A battery-operated pilot balloon time-signal generator

    Science.gov (United States)

    Ralph H. Moltzau

    1966-01-01

    Describes the design and construction of a 1-pound, battery-operated, time-signal transmitter, which is usable with portable radio or field telephone circuits for synchronizing multi-theodolite observation of pilot balloons.

  14. Balloon valvuloplasty for severe mitral valve stenosis in pregnancy

    African Journals Online (AJOL)

    . Commerford, B. Levetan. Balloon Valvuloplasties for severe mitral stenosis were performed on 11 ... 140 patients each year with cardiac disease - an incidence of 0.5%. ... Department of Medicine, Groote Schuur Hospital and University of.

  15. Ballooning stability analysis of JET H-mode discharges

    International Nuclear Information System (INIS)

    O'Brien, D.P.; Galvao, R.; Keilhacker, M.; Lazzaro, E.; Watkins, M.L.

    1989-01-01

    Previous studies of the stability of a large aspect ratio model equilibrium to ideal MHD ballooning modes have shown that across the bulk of the plasma there exist two marginally stable values of the pressure gradient parameter α. These define an unstable zone which separates the first (small α) stable region from the second (large α) stable region. Close to the separatrix, however, the first and second regions can coalesce when the surface averaged current density, Λ, exceeds a critical value. The plasma in this region is then stable to ballooning modes at all values of the pressure gradient. In this paper we extend these results to JET H-mode equilibria using a finite aspect ratio ballooning formalism, and assess the relevance of ideal ballooning stability in these discharges. In particular we analyse shot 15894 at time 56 sec. which is 1.3 s into the H-phase. (author) 4 refs., 4 figs

  16. 10 meter Sub-Orbital Large Balloon Reflector (LBR)

    Data.gov (United States)

    National Aeronautics and Space Administration — This is the lead NIAC Phase II proposal for “10 meter Sub-Orbital Large Balloon Reflector (LBR)” with Christopher K. Walker as PI. We propose to develop and...

  17. SMEX02 Balloon-borne Radiosonde Data, Iowa

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes radiosonde measurements of upper air temperature and pressure, relative humidity, and wind direction and speed during the balloons' ascent to...

  18. Ideal ballooning stability near an equilibrium magnetic island

    Energy Technology Data Exchange (ETDEWEB)

    Hegna, C.C.; Callen, J.D.

    1992-03-01

    The stability properties of ideal ballooning modes on toroidal flux surfaces near a quasistatic magnetic island is examined. On these surfaces, magnetic field-line trajectories tend to bunch on that part of the magnetic surface closet to the X-point of the magnetic island. Because of this preferential bunching, the stabilizing effect of field-line bending due to magnetic shear can be reduced. Eigenfunctions localized in helical angle near the X-point and in poloidal angle on the bad curvature side of the tokamak are more susceptible to ballooning instability than are modes in corresponding equilibria without the magnetic island. For a slowly growing island, a growing number of flux surfaces located near the separatrix become ballooning unstable. Secondary ballooning instabilities may play a part in the crash phase of sawteeth or macroscopic island dynamics.

  19. Properties of ballooning modes in the Heliotron configurations

    International Nuclear Information System (INIS)

    Nakajima, N.; Hudson, S.R.; Hegna, C.C.

    2005-01-01

    The stability of ballooning modes is influenced by the local and global magnetic shear and local and global magnetic curvature so significantly that it is fairly difficult to get those general properties in the three dimensional configurations with strong flexibility due to the external coil system. In the case of the planar axis heliotron configurations allowing a large Shafranov shift, like LHD, properties of the high-mode-number ballooning modes have been intensively investigated. It has been analytically shown that the local magnetic shear comes to disappear in the stellarator-like global magnetic shear region, as the Shafranov shift becomes large. Based on this mechanism and the characteristics of the local and global magnetic curvature, it is numerically shown that the destabilized ballooning modes have strong three-dimensional properties (both poloidal and toroidal mode couplings) in the Mercier stable region, and that those are fairly similar to ballooning modes in the axisymmetric system in the Mercier unstable region. As is well known, however, no quantization condition is applicable to the ballooning modes in the three-dimensional system without symmetry, and so the results of the high-mode-number ballooning modes in the covering space had to be confirmed in the real space. Such a confirmation has been done in the Mercier stable region and also in the Mercier unstable region by using three dimensional linearized ideal MHD stability code cas3d. Confirming the relation between high-mode-number ballooning analyses by the global mode analyses, the method of the equilibrium profile variations has been developed in the tree dimensional system, giving dt/dψ - dP/dψ stability diagram corresponding to the s - α diagram in tokamaks. This method of profile variation are very powerful to investigate the second stability of high-mode-number ballooning modes and has been more developed. Recently it has been applied to the plasma in the inward-shifted LHD

  20. Overview of the Scientific Balloon Activity in Sweden

    Science.gov (United States)

    Abrahamsson, Mattias; Kemi, Stig; Lockowandt, Christian; Andersson, Kent

    SSC, formerly known as Swedish Space Corporation, is a Swedish state-owned company working in several different space related fields, including scientific stratospheric balloon launches. Esrange Space Centre (Esrange in short) located in the north of Sweden is the launch facility of SSC, where both sounding rocket launches and stratospheric balloon launches are conducted. At Esrange there are also facilities for satellite communication, including one of the largest civilian satellite data reception stations in the world. Stratospheric balloons have been launched from Esrange since 1974, when the first flights were performed together with the French space agency CNES. These balloon flights have normally flown eastward either only over Sweden or into Finland. Some flights have also had permission to fly into Russia, as far as the Ural Mountains. Normal flight times are from 4 to 12 hours. These eastward flights are conducted during the winter months (September to May). Long duration flights have been flown from ESC since 2005, when NASA flew the BLAST payload from Sweden to north Canada. The prevailing westerly wind pattern is very advantageous for trans-Atlantic flights during summer (late May to late July). The long flight times are very beneficial for astronomical payloads, such as telescopes that need long observation times. In 2013 two such payloads were flown, the first called SUNRISE was a German/US solar telescope, and the other called PoGOLite with a Swedish gamma-ray telescope. In 14 days PoGOLite, which had permission to fly over Russia, made an almost complete circumpolar flight. Typical scientific balloon payload fields include atmospheric research, including research on ozone depletion, astronomical and cosmological research, and research in technical fields such as aerodynamics. University students from all over Europe are involved in flights from Esrange under a Swedish/German programme called BEXUS. Two stratospheric balloons are flown with student

  1. Endoscopic Urinary Diversion As Initial Management of Symptomatic Obstructive Ectopic Ureter in Infants

    Directory of Open Access Journals (Sweden)

    Ruben Ortiz

    2017-09-01

    Full Text Available AimDefinitive surgery of ectopic ureter in infants is challenging. We propose an endoscopic urinary diversion (EUD as a novel surgical technique in the initial management of symptomatic obstructive ectopic ureter.Patients and methodsSixteen obstructive ectopic ureters (14 patients were initially treated by EUD between 2006 and 2015. All patients had urinary tract dilatation worsening at preoperative US scans and at least two febrile urinary tract infection (UTI or urinary sepsis despite antibiotic prophylaxis. Ectopic ureter was confirmed by cystoscopy. When ectopic meatus was not found, EUD consisted in the creation of a transurethral neo-orifice (TUNO performed by needle puncturing of the ureterovesical wall, under fluoroscopic and ultrasound control. If ectopic meatus was identified in the posterior urethra, “intravesicalization procedure” was done opening the urethral–ureteral wall to create a new ureteral outlet into the bladder.ResultsEUD was done at a median age of 3.5 months (0.5–7 with median follow-up of 48 months (24–136. TUNO was performed in six patients and “intravesicalization” in eight patients. Significant differences were observed in ureteral diameter and anteroposterior pelvis diameter before and after endoscopic treatment (p < 0.005. Initial renal function was preserved in all cases. Postoperative complications were UTI in four patients and TUNO stenosis in one patient, treated by endoscopic balloon dilation. Definitive treatment was further individualized in each patient after 1 year of life.ConclusionEUD is a feasible and safe less-invasive technique in the initial management of symptomatic obstructive ectopic ureter. It allows an adequate ureteral drainage preserving renal function until definitive repair if necessary and does not invalidate other surgical options in case of failure or future definitive treatments.

  2. Ballooning Stability of the Compact Quasiaxially Symmetric Stellarator

    International Nuclear Information System (INIS)

    Redi, M.H.; Canik, J.; Dewar, R.L.; Johnson, J.L.; Klasky, S.; Cooper, W.A.; Kerbichler, W.

    2001-01-01

    The magnetohydrodynamic (MHD) ballooning stability of a compact, quasiaxially symmetric stellarator (QAS), expected to achieve good stability and particle confinement is examined with a method that can lead to estimates of global stability. Making use of fully 3D, ideal-MHD stability codes, the QAS beta is predicted to be limited above 4% by ballooning and high-n kink modes. Here MHD stability is analyzed through the calculation and examination of the ballooning mode eigenvalue isosurfaces in the 3-space [s, alpha, theta(subscript ''k'')]; s is the edge normalized toroidal flux, alpha is the field line variable, and theta(subscript ''k'') is the perpendicular wave vector or ballooning parameter. Broken symmetry, i.e., deviations from axisymmetry, in the stellarator magnetic field geometry causes localization of the ballooning mode eigenfunction, with new types of nonsymmetric, eigenvalue isosurfaces in both the stable and unstable spectrum. The isosurfaces around the most unstable points i n parameter space (well above marginal) are topologically spherical. In such cases, attempts to use ray tracing to construct global ballooning modes lead to a k-space runaway. Introduction of a reflecting cutoff in k(perpendicular) to model numerical truncation or finite Larmor radius (FLR) yields chaotic ray paths ergodically filling the allowed phase space, indicating that the global spectrum must be described using the language of quantum chaos theory. However, the isosurface for marginal stability in the cases studied are found to have a more complex topology, making estimation of FLR stabilization more difficult

  3. Towards automated visual flexible endoscope navigation.

    Science.gov (United States)

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  4. AGA White Paper: Training and Implementation of Endoscopic Image Enhancement Technologies.

    Science.gov (United States)

    Gupta, Neil; Brill, Joel V; Canto, Marcia; DeMarco, Daniel; Fennerty, Brian M; Laine, Loren; Lieberman, David; Lightdale, Charles; Montgomery, Elizabeth; Odze, Robert; Rex, Douglas; Sharma, Prateek; Tokar, Jeffrey L; Kochman, Michael L

    2017-06-01

    Endoscopic image-enhancement technologies provide opportunities to visualize normal and abnormal tissues within the gastrointestinal (GI) tract in a manner that complements conventional white light endoscopic imaging. The additional information that is obtained enables the endoscopist to better identify, delineate, and characterize lesions and can facilitate targeted biopsies or, in some cases, eliminate the need to send samples for histologic analysis. Some of these technologies have been available for more than a decade, but despite this fact, there is limited use of these technologies by endoscopists. Lack of formalized training in their use and a scarcity of guidelines on implementation of these technologies into clinical practice are contributing factors. In November 2014, the American Gastroenterological Association's Center for GI Innovation and Technology conducted a 2-day workshop to discuss endoscopic image-enhancement technologies. This article represents the third of 3 separate documents generated from the workshop and discusses the published literature pertaining to training and outlines a proposed framework for the implementation of endoscopic image-enhancement technologies in clinical practice. There was general agreement among participants in the workshop on several key considerations. Training and competency assessment for endoscopic image-enhancement technologies should incorporate competency-based education paradigms. To facilitate successful training, multiple different educational models that can cater to variations in learning styles need to be developed, including classroom-style and self-directed programs, in-person and web-based options, image and video atlases, and endoscopic simulator programs. To ensure safe and appropriate use of these technologies over time, refresher courses, skill maintenance programs, and options for competency reassessment should be established. Participants also generally agreed that although early adopters of

  5. Endoscopic submucosal dissection with a combination of small-caliber-tip transparent hood and flex knife is a safe and effective treatment for superficial esophageal neoplasias.

    Science.gov (United States)

    Ishii, Naoki; Horiki, Noriyuki; Itoh, Toshiyuki; Uemura, Masayo; Maruyama, Masataka; Suzuki, Shoko; Uchida, Shino; Izuka, Yusuke; Fukuda, Katsuyuki; Fujita, Yoshiyuki

    2010-02-01

    Superficial esophageal neoplasias resected in piecemeal manner with endoscopic mucosal resection (EMR) sometimes recur locally, and additional treatments need to be developed. Efficacy and safety of endoscopic submucosal dissection (ESD) for esophageal neoplasias are not sufficiently demonstrated, so we conducted a retrospective study to evaluate the efficacy and safety of ESD for superficial esophageal neoplasias. Thirty-seven superficial esophageal neoplasias consisted of 34 squamous cell neoplasias and 3 columnar neoplasias in 35 patients were treated with ESD from May 2006 to July 2008. Patients were regularly followed up with endoscopy every 6 months, and with echoendoscope and computed tomography every year. Therapeutic efficacy, complications, and follow-up results were evaluated. The mean size of the resected neoplasias and that of the resected specimens were 22 mm (range 10-83 mm) and 41 mm (range 18-90 mm), respectively. The mean duration of the ESD procedures was 117 min (range 40-235 min). The overall rates of en bloc resection and of free margin resection were 100% (37/37) and 95% (35/37), respectively. The mean follow-up period of 19 months (range 7-32 months) revealed no local or distant recurrence. There were no complications such as bleeding or perforation in any case. In all nine cases, the strictures were successfully managed with prophylactic endoscopic balloon dilation. ESD with a combination of small-caliber-tip transparent hood and flex knife is a safe endoscopic treatment for superficial esophageal neoplasias and enables large en bloc resection.

  6. Percutaneous endoscopic gastrostomy in children.

    Science.gov (United States)

    Park, Jye Hae; Rhie, Seonkyeong; Jeong, Su Jin

    2011-01-01

    Percutaneous endoscopic gastrostomy (PEG) can improve nutritional status and reduce the amount of time needed to feed neurologically impaired children. We evaluated the characteristics, complications, and outcomes of neurologically impaired children treated with PEG. We retrospectively reviewed the records of 32 neurologically impaired children who underwent PEG between March 2002 and August 2008 at our medical center. Forty-two PEG procedures comprising 32 PEG insertions and 10 PEG exchanges, were performed. The mean follow-up time was 12.2 (6.6) months. Mean patient age was 9.4 (4.5) years. The main indications for PEG insertion were swallowing difficulty with GI bleeding due to nasogastric tube placement and/or the presence of gastroesophageal reflux disease (GERD). The overall rate of complications was 47%, with early complications evident in 25% of patients and late complications in 22%. The late complications included one gastro-colic fistula, two cases of aggravated GERD, and four instances of wound infection. Among the 15 patients with histological evidence of GERD before PEG, 13 (87%) had less severe GERD, experienced no new aspiration events, and showed increased body weight after PEG treatment. PEG is a safe, effective, and relatively simple technique affording long-term enteral nutritional support in neurologically impaired children. Following PEG treatment, the body weight of most patients increased and the levels of vomiting, GI bleeding, and aspiration fell. We suggest that PEG with post-procedural observation be considered for enteral nutritional support of neurologically impaired children.

  7. Endoscopic treatment of prepatellar bursitis.

    Science.gov (United States)

    Huang, Yu-Chih; Yeh, Wen-Lin

    2011-03-01

    Operative treatment of prepatellar bursitis is indicated in intractable bursitis. The most common complication of surgical treatment for prepatellar bursitis is skin problems. For traumatic prepatellar bursitis, we propose a protocol of outpatient endoscopic surgery under local anaesthesia. From September 1996 to February 2001, 60 cases of failed nonoperative treatment for prepatellar bursitis were included. The average age was 33.5 ± 11.1 years (range 21-55). The average operation duration was 18 minutes. Two to three mini-arthroscopic portals were used in our series. No sutures or a simple suture was needed for the portals after operation. After follow-up for an average of 36.3 months, all patients are were symptom-free and had regained knee function. None of the population had local tenderness or hypo-aesthesia around their wound. Their radiographic and sonographic examinations showed no recurrence of bursitis. Outpatient arthroscopic bursectomy under local anaesthesia is an effective procedure for the treatment of post-traumatic prepatellar bursitis after failed conservative treatments. Both the cosmetic results and functional results were satisfactory.

  8. Training in Endoscopy: Endoscopic Ultrasound.

    Science.gov (United States)

    Cho, Chang Min

    2017-07-01

    Endoscopic ultrasound (EUS) has been recently established as an indispensable modality for the diagnosis and management of pancreatobiliary and gastrointestinal (GI) disorders. EUS proficiency requires both cognitive and technical abilities, including an understanding of the appropriate indications, the performance of appropriate evaluations before and after the procedure, and the management of procedure-related complications. An increasing demand for skills to handle a growing range of interventional EUS procedures and a continual shortage of EUS training programs are two major obstacles for EUS training. Acquiring the skills necessary to comprehend and conduct EUS often requires training beyond the scope of a standard GI fellowship program. In addition to traditional formal EUS training and preceptorships, regular short-term intensive EUS training programs that provide training at various levels may help EUS practitioners improve and maintain EUS-related knowledges and skills. Theoretical knowledge can be acquired from lectures, textbooks, atlases, slides, videotapes, digital video discs, interactive compact discs, and websites. Informal EUS training is generally based on 1- or 2-day intensive seminars, including didactic lectures, skills demonstrated by expert practitioners through live video-streaming of procedures, and hands-on learning using animal or phantom models.

  9. Early Squamous Neoplasia of the Esophagus: The Endoscopic Approach to Diagnosis and Management

    Science.gov (United States)

    Kandiah, Kesavan; Chedgy, Fergus J. Q.; Subramaniam, Sharmila; Thayalasekaran, Sreedhari; Kurup, Arun; Bhandari, Pradeep

    2017-01-01

    Considerable focus has been placed on esophageal adenocarcinoma in the last 10 years because of its rising incidence in the West. However, squamous cell cancer (SCC) continues to be the most common type of esophageal cancer in the rest of the world. The detection of esophageal SCC (ESCC) in its early stages can lead to early endoscopic resection and cure. The increased incidence of ESCC in high-risk groups, such as patients with head and neck squamous cancers, highlights the need for screening programs. Lugol's iodine chromoendoscopy remains the gold standard technique in detecting early ESCC, however, safer techniques such as electronic enhancement or virtual chromoendoscopy would be ideal. In addition to early detection, these new “push-button” technological advancements can help characterize early ESCC, thereby further aiding the diagnostic accuracy and facilitating resection. Endoscopic resection (ER) of early ESCC with negligible risk of lymph node metastases has been widely accepted as an effective therapeutic strategy because it offers similar success rates when compared to esophagectomy, but carries lesser morbidity and mortality. Endoscopic submucosal dissection (ESD) is the preferred technique of ER in lesions larger than 15 mm because it provides higher rates of en bloc resections and lower local recurrence rates when compared to endoscopic mucosal resection (EMR). PMID:28361837

  10. A creative analysis of the role of practice development facilitators in a critical care environment

    Directory of Open Access Journals (Sweden)

    Tanya Heyns

    2017-10-01

    Full Text Available Practice development focuses on methods to address the quality of care and advance healthcare practices. The role of practice development facilitators to address challenges of delivering evidence-based person-centred care in the critical care environment was determined by using a nominal group technique. Eleven participants from public and private healthcare services reached consensus on seven clusters: theory-practice application, facilitation of learning, increasing collaboration, effective communication, facilitation of change, time management and role modelling. The clusters were visually represented as a hot air balloon. Competence as facilitators is of vital importance to ensure knowledge translation with the aim to improve quality.

  11. Controlled weather balloon ascents and descents for atmospheric research and climate monitoring

    Science.gov (United States)

    Kräuchi, Andreas; Philipona, Rolf; Romanens, Gonzague; Hurst, Dale F.; Hall, Emrys G.; Jordan, Allen F.

    2016-03-01

    In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earth's surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.

  12. Endoscopic ultrasound-guided drainage of pancreatic pseudocysts

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Andreas; Vilmann, Peter

    2015-01-01

    Pancreatic pseudocysts are fluid collections in the peripancreatic tissues associated with acute or chronic pancreatitis. Endoscopic ultrasound (EUS)-guided drainage has become an established indication, having better results as compared to percutaneous drainage, nonguided endoscopic drainage...

  13. Balloon catheter dilatation of benign urethral strictures

    International Nuclear Information System (INIS)

    Perini, L.; Cavallo, A.; Perin, B.; Bighi, G.

    1988-01-01

    The authors report their experience of benign urethral stricture dilatation by balloon catheter in 11 male patients. Ten posterior and 2 anterior urethral strictures were treated; in 1 patients several narrowings coexisted at various levels. Etiology was inflammatory in 4 cases, iatrogen in 3, post-traumatic in 2, and equivocal in 2. The patients were studied both before and soon after dilatation by means of retrograde and voiding cystourethrogram and uroflowgraphy; the follow-up (2-14 months) was performed by urodynamic alone. In all cases, dilatation was followed by the restoration of urethral gauge, together with prompt functional improvement of urodynamic parameters. The latter result subsisted in time in 9 patients. In 2 cases recurrences were observed demonstrated at once by clinics and urodynamics. Both lesions were successfully re-treated. Neither early not late complication occurred. In spite of the limited material, the valuable results obtained, together with the absence of complications, the peculiar morphology of recurrences, and the chance of repeating it make the procedure advisable as a valid alternative to conventional techniques for these pathologies

  14. Retrograde prostatic urethroplasty with a balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Reddy, P.; Hulbert, J.; Letourneau, J.G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1987-01-01

    Twenty-five patients with prostatism and documented BPH who were candidates for transurethral resection of the prostate were dilated for 10 minutes with 25-mm urethroplasty balloons using a retrograde transurethral approach. The procedure was performed under local anesthesia using 2% viscous lidocaine on an outpatient basis. A mild discomfort was experienced by all patients with a moderate urgency sensation. Mild transient hematuria was present in all, which cleared in 4 to 6 hours. Dysuria usually lasted for 72 hours. Significant improvement has been seen in the relief of symptoms in patients without middle-lobe hypertrophy as documented by uroflow studies, voiding cystourethrograms, and retrograde urethrograms. In patients with middle-lobe hypertrophy, moderate improvement in uroflow studies was observed, which correlated well with symptomatic improvement. Rectal US and MR studies have shown no evidence of intraprostatic or periprostatic abnormalities. No complications have been encountered so far. The longest current follow-up is 20 months, with a mean of 10 months

  15. Mechanism of prostatic urethroplasty with balloon catheter

    International Nuclear Information System (INIS)

    Castaneda, F.; Maynar, M.; Hulbert, J.

    1988-01-01

    A series of 60 patients have undergone prostatic urethroplasty with balloon catheters at our institution. The follow-up of these patients has ranged from more than 3 years to not less than 6 months. The preliminary results have been excellent, with a success rate of 75% in patients with predominant lateral lobe hypertrophy. This success rate drops to 25% in patients with predominant middle lobe hypertrophy. In previous communications the authors have proposed that the mechanism of prostatic urethral relief of obstruction is due to stretching of the prostatic capsule, tissue compression, and possible subsequent atrophy, as suggested by findings of transrectal US, MR imaging, voiding and retrograde urethrography, and urinary flow studies. Recent clinical information that has led to further animal research has shown that in addition to the previously supposed mechanism of action, separation of the prostatic lobes occurs by splitting of the anterior and posterior commissures of the prostatic gland tissue. This separation of the prostatic lobes is therefore the goal of the procedure. As more experience is gained, the already high success rate can probably be improved

  16. Percutaneous balloon valvuloplasty in mitral stenosis

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Oh, Byung Hee; Park, Kyung Ju; Kim, Seung Hyup; Lee, Young Woo; Han, Man Chung

    1989-01-01

    Percutaneous balloon valvuloplasty(PBV) was successfully performed in 8 mitral stenosis patients for recent 3 months. Five patients have aortic insufficiencies also and two patients have mitral regurgitations below grade II/IV. All patients showed sinus rhythm on EKG, and had no mitral valvular calcification on echocardiography and fluoroscopy. PBV resulted in an increase in mitral valve area from 1.22±0.22 to 2.57±0.86 cm 2 , a decrease in mean left atrial pressure from 23.4±9.6 to 7.5±3.4 mmHg and a decrease in mean mitral pressure gradient from 21.3±9.4 to 6.8±3.1 mmHg. There were no significant complications except 2 cases of newly appeared and mildly aggravated mitral regurgitation. We believe that PBV will become a treatment modality of choice replacing surgical commissurotomy or valve replacement in a group of mitral stenosis patients, because of its effectiveness and safety

  17. [Natural Orifice Transluminal Endoscopic Surgery (NOTES)].

    Science.gov (United States)

    Kim, Yong Sik; Kim, Chul Young; Chun, Hoon Jai

    2008-03-01

    Recently, the field of gastrointestinal endoscopy is developing rapidly. Once limited to the gastroinstestinal lumen, the endoscopic technology is now breaking the barriers and extending its boundary to peritoneal and pleural space. In 2004, Dr. Kalloo, a gastroenterologist, observed intraperitoneal organs of a pig using a conventional endoscope through the stomach wall. Since then, new endoscopic technique of intraperitoneal intervention with transluminal approach named the Natural Orifice Transluminal Endoscopic Surgery or NOTES has been introduced. NOTES reaches the target organ by inserting the endoscope through a natural orifice (e.g. mouth, anus, vagina, urethra) and entering the peritoneal lumen by means of making an incision on the luminal wall. After a series of successful experiences in animal studies, NOTES are now being tried on human subjects. There are still many obstacles to overcome, but bright future for this new technology is expected because of its proposed advantages of less pain, lower complication rate, short recovery time, and scarless access. In this review, we plan to learn about NOTES.

  18. Endoscopic techniques in oral and maxillofacial surgery.

    Science.gov (United States)

    Pedroletti, Fred; Johnson, Brad S; McCain, Joseph P

    2010-02-01

    Oral and maxillofacial surgery is entering a new era. Surgeons can use the latest technological advances in equipment in an attempt to improve patient outcomes. Minimally invasive surgery with the use of the endoscope has improved in recent years because of technological advancements in optics and associated instrumentation. Trauma, orthognathic, sialoendoscopy, and temporomandibular joint surgery are commonly performed with the assistance of the endoscope. From an educational standpoint, surgical anatomy and various other principles can easily be taught to trainees with the assistance of the endoscope. The operating surgeon can visualize an area via the endoscope, and instruct regarding the surgical maneuvers on the monitor, without obstructions to view. This technique also allows others in and out of the room to view the image. Endoscopically assisted surgery is gaining popularity and is becoming a tool frequently used by surgeons to assist in and simplify some of the more difficult techniques that often require more extensive surgical exposure for visualization. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  19. Nasal encephalocele: endoscopic excision with anesthetic consideration.

    Science.gov (United States)

    Abdel-Aziz, Mosaad; El-Bosraty, Hussam; Qotb, Mohamed; El-Hamamsy, Mostafa; El-Sonbaty, Mohamed; Abdel-Badie, Hazem; Zynabdeen, Mustapha

    2010-08-01

    Nasal encephalocele may presents as a nasal mass, its treatment is surgical and it should be done early in life. When removal is indicated, there are multiple surgical approaches; including lateral rhinotomy, a transnasal approach and a coronal flap approach. However, the treatment of a basal intranasal encephalocele using transnasal endoscopic approach could obviates the possible morbidity associated with other approaches. The aim of this study was to evaluate the efficacy of endoscopic removal of intranasal encephalocele, also to document the role of anesthetist in the operative and postoperative periods. Nine cases with nasal encephalocele were included in this study; CT and/or MRI were used in their examination. The lesions were removed via transnasal endoscopic approach. Preoperative evaluation, intervention and postoperative follow-up were presented with discussion of anesthesia used for those children. The lesions of all patients were removed successfully with no recurrence through the follow-up period of at least 21 months. No cases showed morbidity or mortality intra- or post-operatively. Endoscopic excision of intranasal encephalocele is an effective method with high success rate. Anesthetist plays an important role in the operative and postoperative period, even during the endoscopic follow up; sedation of the children is usually needed. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Novel and safer endoscopic cholecystectomy using only a flexible endoscope via single port.

    Science.gov (United States)

    Mori, Hirohito; Kobayashi, Nobuya; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Chiyo, Taiga; Ayaki, Maki; Nagase, Takashi; Masaki, Tsutomu

    2016-04-07

    To apply the laparoscopic and endoscopic cooperative surgery concept, we investigated whether endoscopic cholecystectomy could be performed more safely and rapidly via only 1 port or not. Two dogs (11 and 13-mo-old female Beagle) were used in this study. Only 1 blunt port was created, and a flexible endoscope with a tip attachment was inserted between the fundus of gallbladder and liver. After local injection of saline to the gallbladder bed, resection of the gallbladder bed from the liver was performed. After complete resection of the gallbladder bed, the gallbladder was pulled up to resect its neck using the Ring-shaped thread technique. The neck of the gallbladder was cut using scissor forceps. Resected gallbladder was retrieved using endoscopic net forceps via a port. The operation times from general anesthetizing with sevoflurane to finishing the closure of the blunt port site were about 50 min and 60 min respectively. The resection times of gallbladder bed were about 15 min and 13 min respectively without liver injury and bleeding at all. Feed were given just after next day of operation, and they had a good appetite. Two dogs are in good health now and no complications for 1 mo after endoscopic cholecystectomy using only a flexible endoscope via one port. We are sure of great feasibility of endoscopic cholecystectomy via single port for human.

  1. Cost-effectiveness of endoscopic ultrasonography, magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography in patients suspected of pancreaticobiliary disease

    DEFF Research Database (Denmark)

    Ainsworth, A P; Rafaelsen, S R; Wamberg, P A

    2004-01-01

    BACKGROUND: It is not known whether initial endoscopic ultrasonography (EUS) or magnetic resonance cholangiopancreatography (MRCP) is more cost effective than endoscopic retrograde cholangiopancreatography (ERCP). METHODS: A cost-effectiveness analysis of EUS, MRCP and ERCP was performed on 163...

  2. Post-endoscopic biliary sphincterotomy bleeding: an interventional radiology approach.

    LENUS (Irish Health Repository)

    Dunne, Ruth

    2013-12-01

    Endoscopic sphincterotomy is an integral component of endoscopic retrograde cholangiopancreatography. Post-sphincterotomy hemorrhage is a recognized complication. First line treatment involves a variety of endoscopic techniques performed at the time of sphincterotomy. If these are not successful, transcatheter arterial embolization or open surgical vessel ligation are therapeutic considerations.

  3. Cerebral ischemia associated with PercuSurge balloon occlusion balloon during carotid stenting: Incidence and possible mechanisms.

    Science.gov (United States)

    Chaer, Rabih A; Trocciola, Susan; DeRubertis, Brian; Lin, Stephanie C; Kent, K Craig; Faries, Peter L

    2006-05-01

    Interruption of antegrade cerebral perfusion results in transient neurologic intolerance in some patients undergoing carotid angioplasty and stenting (CAS). This study sought to evaluate factors that contributed to the development of cerebral ischemia during PercuSurge balloon occlusion and techniques used to allow successful completion of the CAS procedure. The PercuSurge occlusion balloon was used in 43 of 165 patients treated with CAS for high-grade stenosis (mean stenosis, 90%). All 43 patients were at increased risk for endarterectomy (7 restenosis, 3 irradiation, 3 contralateral occlusion, and 30 Goldman class II-III); 20% were symptomatic. Symptoms of cerebral hypoperfusion during temporary occlusion of the internal carotid artery occurred in 10 of 43 and included dysarthria (7/10), agitation (6/10), decreased level of consciousness (5/10), and focal hemispheric deficit (3/10). An incomplete circle of Willis or contralateral carotid artery occlusion, or both, was present in 8 of 10 patients. Symptoms resulting from PercuSurge balloon occlusion were managed by balloon deflation with or without evacuation of blood from the internal carotid artery using the Export catheter. All symptoms resolved completely without deficit after deflation of the occlusion balloon. The development of neurologic symptoms after initial PercuSurge balloon inflation and occluded internal carotid artery flow was associated with a decrease in the mean Glasgow Coma Scale (GCS) from 15 to 10 (range, 9 to 14); the GCS returned to normal after occlusion balloon deflation and remained normal during subsequent reinflation. The mean time to spontaneous recovery of full neurologic function was 8 minutes (range, 4 to 15 minutes). No thrombotic or embolic events were present on cerebral angiography or computed tomography scan. Balloon reinflation was performed after a mean reperfusion interval of 10 minutes after full neurologic recovery (range, 4 to 20 minutes). The mean subsequent procedure

  4. Mesenteric findings of CT enterography are well correlated with the endoscopic severity of Crohn’s disease

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Takehiro [Department of Medicine and Clinical Oncology (K1), Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba-shi 260-8670, Chiba (Japan); Katsuno, Tatsuro, E-mail: katsuno@faculty.chiba-u.jp [Kashiwanoha Clinic, Chiba University, 6-2-1 Kashiwanoha, Kashiwa-shi, 277-0882, Chiba (Japan); Saito, Keiko; Yoshihama, Sayuri; Nakagawa, Tomoo; Koseki, Hirotaka; Taida, Takashi; Ishigami, Hideaki; Okimoto, Ken-ichiro; Maruoka, Daisuke; Matsumura, Tomoaki; Arai, Makoto; Yokosuka, Osamu [Department of Medicine and Clinical Oncology (K1), Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba-shi 260-8670, Chiba (Japan)

    2017-04-15

    Background: Maintenance of mucosal healing is a primary goal when treating Crohn’s disease (CD). Endoscopy is the most precise method for the assessment of mucosal healing, but is considered overly invasive for patients with CD. In contrast, CT enterography (CTE) is less invasive, but little is known about the correlation between mucosal status and CTE parameters. Methods: We recruited CD patients who underwent CTE and double balloon endoscopy (DBE) on the same day at our hospital between 2012 and 2014. CTE parameters evaluated included bowel-wall thickening, mural hyperenhancement, mural stratification (target sign), submucosal fat deposition, mesenteric hypervascularity (comb sign), increased fat density, mesenteric fibrofatty proliferation, enlarged mesenteric lymph nodes, and stenosis/sacculation. Endoscopic findings were evaluated using the Simple Endoscopic Score for Crohn’s Disease (SES-CD). CTE parameters that were predictive of higher values in the SES-CD were extracted statistically. Results: Forty-one patients were recruited, from which 191 intestinal segments were evaluated. Spearman’s rank correlation coefficients showed that the majority of CTE values exhibited mild to moderate correlations with SES-CD values. Notably, multiple ordinal logistic regression analysis demonstrated that CTE findings obtained from the mesenteric area, such as mesenteric hypervascularity (comb sign) and enlarged mesenteric lymph nodes, were more critical predictors of endoscopic mucosal ulceration than those obtained from the bowel wall. Conclusions: This study was the first of its kind to assess correlations between CTE values and SES-CD values. Mesenteric findings of CTE, rather than mural findings, were highly correlated with the endoscopically evaluated severity of ulceration.

  5. Percutaneous endoscopic gastrostomy in children

    Directory of Open Access Journals (Sweden)

    Jye Hae Park

    2011-01-01

    Full Text Available Purpose: Percutaneous endoscopic gastrostomy (PEG can improve nutritional status and reduce the amount of time needed to feed neurologically impaired children. We evaluated the characteristics, complications, and outcomes of neurologically impaired children treated with PEG. Methods: We retrospectively reviewed the records of 32 neurologically impaired children who underwent PEG between March 2002 and August 2008 at our medical center. Forty-two PEG procedures comprising 32 PEG insertions and 10 PEG exchanges, were performed. The mean follow-up time was 12.2 (6.6 months. Results: Mean patient age was 9.4 (4.5 years. The main indications for PEG insertion were swallowing difficulty with GI bleeding due to nasogastric tube placement and/or the presence of gastroesophageal reflux disease (GERD. The overall rate of complications was 47%, with early complications evident in 25% of patients and late complications in 22%. The late complications included one gastro-colic fistula, two cases of aggravated GERD, and four instances of wound infection. Among the 15 patients with histological evidence of GERD before PEG, 13 (87% had less severe GERD, experienced no new aspiration events, and showed increased body weight after PEG treatment. Conclusion: PEG is a safe, effective, and relatively simple technique affording long-term enteral nutritional support in neurologically impaired children. Following PEG treatment, the body weight of most patients increased and the levels of vomiting, GI bleeding, and aspiration fell. We suggest that PEG with post-procedural observation be considered for enteral nutritional support of neurologically impaired children.

  6. [Per-oral endoscopic myotomy in achalasia].

    Science.gov (United States)

    Ponds, Fraukje A M; Smout, André J P M; Bredenoord, Albert J; Fockens, Paul

    2015-01-01

    The treatment of patients with achalasia is complex due to a considerably high recurrence rate and risk of treatment-related complications. The per-oral endoscopic myotomy (POEM) is a new endoscopic technique that combines the benefits of a minimally invasive endoscopic procedure with the efficacy of a surgical myotomy. Implementation of the POEM technique may lead to fewer complications, a lower recurrence rate and reduced costs. During the procedure, a myotomy of the circular muscle layer of the oesophagus is performed after creating a submucosal tunnel in the oesophagus. The first studies of this new technique show promising results. Experienced therapeutic endoscopists can learn to perform the POEM technique relatively easily. Further studies are needed to compare this technique with the current standard treatments and to evaluate long-term effects.

  7. [Endoscopic classification of colon and rectal neoplasias].

    Science.gov (United States)

    Zavoral, Miroslav; Vojtěchová, Gabriela; Suchánek, Stěpán

    2014-01-01

    Along with the dynamic evolution of the new field of digestive endoscopy, the need of unified and unambiguous terms for endoscopic findings arose in the second half of the 20th century. In collaboration with the OMED members, professor Zdeněk Mařatka drew up the first internationally acknowledged terminology for digestive endoscopy which was used in the full range for a period of almost 20 years. The technical progress later brought with it endoscopes which made it possible to view flat lesions, frequently overlooked until then. The classification of the surface lesions was further specified by the Paris Classification which drew from the experience of Japanese endoscopists. Thanks to the new endoscopic methods of imaging mucosa in vivo and the pit-pattern and vascular-pattern classification, we can currently estimate the biological nature of lesion with great accuracy and therefore choose the best therapeutic procedure.

  8. Diagnosis and treatment with endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Soendenaa, K.; Horn, A.; Viste, A.

    1994-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) was carried out for the first time in 1968. Five years later endoscopic sphincterotomy was performed. Since then both modalities have become established as necessary adjuncts in the diagnosis and treatment of patients with pathology in the bile duct or pancreas. The main indication is common bile duct stone, and as a consequence of this treatment fewer patients are now treated surgically. Patients with malignant bile duct obstruction can be given reasonable palliation of both jaundice and pruritus and therefore improved quality of life. Some reports indicate that endoscopic drainage may be useful for pancreatic stenosis. Complications are few, but vigilance and prompt treatment is necessary to keep morbidity at a minimum. Follow-up after several years shows that sphincterotomy is successful also in the long term. The authors discuss the present diagnostic and therapeutic situation. 31 refs., 2 tabs

  9. Endoscopic and Photodynamic Therapy of Cholangiocarcinoma.

    Science.gov (United States)

    Meier, Benjamin; Caca, Karel

    2016-12-01

    Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA.

  10. Using external magnet guidance and endoscopically placed magnets to create suture-free gastro-enteral anastomoses.

    Science.gov (United States)

    Myers, Christopher; Yellen, Benjamin; Evans, John; DeMaria, Eric; Pryor, Aurora

    2010-05-01

    To facilitate endolumenal and natural orifice procedures, this study evaluated a novel technique using external and endoscopically placed magnets to create suture-free gastroenteral anastomoses. Seven anesthetized adult swine underwent endoscopic placement of magnets into the small bowel and stomach. Using external magnets, the endoscopically placed internal magnets were brought into opposition under endoscopic view. After 1-2 weeks, the pigs were killed and analyzed. At laparotomy and under sterile conditions, peritoneal cultures were obtained. The anastomoses were evaluated endoscopically and tested using an air insufflation test. Finally, the anastomoses were resected and evaluated microscopically. The average operative time for endoscopic placement of the magnets was 34.3 +/- 14.8 min. Successful placement and creation of anastomoses occurred in six of the pigs. One pig did not form an anastomosis because the magnets were too large to pass through the pylorus at the time of attempted magnet placement. Six swine experienced uncomplicated postoperative courses. One pig's postoperative course involved constipation for several days, requiring additional fluids and fiber supplementation. The findings at endoscopy showed that the magnets were adhered to the anastomosis, which were easily freed, or within the stomach. The air insufflation test results were negative for all the pigs. At laparotomy, there was no evidence of infection, abscess, or leak, but two peritoneal culture results were positive with scant growth of Staphylococcus aureus and coagulase-negative staphylococcus, presumably contaminants. Microscopically, the anastomoses illustrated granulation and fibrous connective tissue without evidence of infection or leak. Endoscopically placed magnets with external magnet guidance is a feasible and novel approach to creating patent gastroenteral anastomoses without abdominal incisions or sutures.

  11. Use of gastric balloon manometry for estimation of intra-abdominal pressure in horses.

    Science.gov (United States)

    Canola, P A; Perotta, J H; Laskoski, L M; Escobar, A; Melo e Silva, C A; Canola, J C; Johnson, P J; Valadão, C A A

    2011-11-01

    Standing laparoscopic procedures, facilitated by abdominal insufflation with carbon dioxide, are being employed to an increasingly greater extent in horses. However, a sustained increase in abdominal pressure may be life-threatening. A practical method for intra-abdominal pressure (IAP) assessment is imperative. Although indirect methods for estimating IAP have been extensively studied in man, little work has been performed in veterinary medicine. To investigate the utility of gastric manometry for purposes of evaluating IAP in horses. Gastric pressure (P(ga) ) was estimated by balloon manometry in 8 healthy, mature horses, before and during a 30 min passive pneumoperitoneum induced by right paralumbar puncture. The balloon manometer was positioned within the gastric lumen and inflated using 2 separate volumes of air: 10 and 50 ml. P(ga) Gastric pressure was determined at baseline (0) and 5, 15 and 30 min after induction of passive pneumoperitoneum. Intra-abdominal pressure was measured directly by right paralumbar puncture using an 8 gauge needle at baseline and immediately following establishment of passive pneumoperitoneum. Baseline IAP values were negative and increased (P≤0.05) during development of passive pneumoperitoneum. However, recorded P(ga) measurements for both inflation volumes were positive before (baseline) and during the course of the passive pneumoperitoneum. Measured P(ga) values did not correlate with IAP at any time. Our results suggest that the indirect method used in human patients for estimating IAP by P(ga) is not applicable for horses. © 2011 EVJ Ltd.

  12. Endoscopic management of glabellar frown lines.

    Science.gov (United States)

    Hamas, R S

    1995-10-01

    Resection of the corrugator muscles has been done for years as a routine adjunct to open coronal browlifts. The new endoscopic procedure described here permits endoscopic resection of the corrugator muscles through three 5-mm hairline incisions in those patients who do not need or want a browlift. The primary benefit is that of reducing the subconscious tendency to frown that some patients exhibit whenever concentrating or conversing. Although patients typically seek plastic surgery procedures to improve how they see themselves, these patients seek a reduction in the subconscious frown to improve how others see them and react to this unattractive facial expression.

  13. ENDOSCOPIC TECHNOLOGIES IN EARLY RECTAL CANCER TREATMENT

    Directory of Open Access Journals (Sweden)

    D. V. Samsonov

    2015-01-01

    Full Text Available Total mesorectal excision is the “golden standard” of surgical treatment for rectal cancer. Development of endoscopic technologies allowed to implement the benefits of minimally invasive surgery in early rectal cancer treatment, decrease morbidity and mortality, improve functional outcome and quality of life. Oncological safety of this method is still a subject for discussion due to lack of lymph node harvest. Endoscopic operations for early rectal cancer are being actively implemented in daily practice, but lack of experience does not allow to include this method in national clinical prac-tice guidelines.

  14. The ATIC Long Duration Balloon Project

    Science.gov (United States)

    Guzik, T.

    Long Duration Balloon (LDB) scientific experiments, launched to circumnavigate the south pole over Antarctica, have particular advantages compared to Shuttle or other Low Earth Orbit (LEO) missions in terms of cost, weight, scientific "duty factor" and work force development. The Advanced Thin Ionization Calorimeter (ATIC) cosmic ray astrophysics experiment is a good example of a university-based project that takes full advantage of current LDB capability and could effectively use future expansion in launch weight and flight duration. The ATIC experiment is currently being shipped to Antarctica in preparation for its first LDB science flight that will investigate the charge composition and energy spectra of primary cosmic rays over the energy range from about 101 0 to 10 1 4 eV. The instrument is built around a fully active, Bismuth Germanate (BGO) ionization calorimeter to measure the energy deposited by the cascades formed by particles interacting in a thick carbon target. A highly segmented silicon matrix, located above the target, provides good incident charge resolution plus rejection of the "backscattered" particles from the interaction. Trajectory reconstruction is based on the cascade profile in the BGO calorimeter, plus information from the three scintillator hodoscope layers in the target section above it. The hodoscope planes also provide the primary event trigger to initiate the detector readout, another measure of the incident particle charge and an indicator of the interaction point in the carbon material. The scientific payload weighs ~1,540 kg and consumes ~300 Watts of power supplied by a ~580 Watt solar array system. A full evaluation of the experiment was performed during a test flight occurring between 28 December 2000 and 13 January 2001 where ATIC was carried3 to an altitude of ~37 km above Antarctica by a ~850,000 m helium filled balloon for one circumnavigation of the continent. All systems behaved well, the detectors performed as expected

  15. Ideal ballooning stability of JET discharges

    International Nuclear Information System (INIS)

    Galvao, R.M.O.; Lazzaro, E.; O'Rourke, J.; Smeulders, P.; Schmidt, G.

    1989-01-01

    Conditions under which ballooning modes are expected to be excited have recently been obtained in two different types of discharges in JET. In the first type, discharges with β approaching the Troyon-Sykes-Wesson critical value β c for optimised pressure profiles have been produced at low toroidal fields (B T =1.5T). In the second type, extremely high pressure gradients have been produced in the plasma core through pellet injection in the current rise phase of the discharge followed by strong additional heating. The stability of these discharges has been studied with the stability code HBT coupled to the equilibrium identification code IDENTC. The equilibrium pressure and diamagnetic function profiles are determined in IDENTC by an optimisation procedure to fit the external magnetic measurements. The resulting pressure profile in the equatorial plane is then compared with the profile derived from 'direct' measurements, i.e. electron density and temperature profiles measured by the LIDAR diagnostic system, ion-temperature profile measured by the charge-exchange diagnostic system, and ion density profile calculated from the Z eff and electron density profiles. Furthermore, the value of the safety factor q on axis is compared with that determined from polarimetry. When good agreement is found, the output data from IDENTC is passed directly to HBT to carry out the stability analysis. When there is not a good agreement, as in the case of pellet discharges with highly peaked pressure profiles, the equilibrium is reevaluated using the 'experimental' profile and the data from polarimetry. (author) 6 refs., 4 figs

  16. Advances in the Remote Monitoring of Balloon Flights

    Science.gov (United States)

    Breeding, S.

    At the National Scientific Balloon Facility (NSBF), we must staff the Long Duration Balloon (LDB) control center 24 hours a day during LDB flights. This requires three daily shifts of two operators (balloon control and tdrss scheduling). In addition to this we also have one engineer on-call as LDB Lead to resolve technical issues and one manager on-call for flight management. These on-call periods are typically 48 to 72 hours in length. In the past the on-call staff had to travel to the LDB control center in order to monitor the status of a flight in any detail. This becomes problematic as flight durations push out beyond 20 to 30 day lengths, as these staff members are not available for business travel during these periods. This paper describes recent advances which allow for the remote monitoring of scientific balloon flight ground station computer displays. This allows balloon flight managers and lead engineers to check flight status and performance from any location with a network or telephone connection. This capability frees key personnel from the NSBF base during flights. It also allows other interested parties to check on the flight status at their convenience.

  17. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    This paper presents a study of pumpkin-shaped superpressure balloons consisting of gores made from a thin polymeric film attached to high stiffness meridional tendons This type of design is being used for the NASA ULDB balloons The gore film shows considerable time-dependent stress relaxation whereas the behaviour of the tendons is essentially time-independent Upon inflation and pressurization the instantaneous i e linear-elastic strain and stress distributions in the film show significantly higher values in the meridional direction However over time and due to the biaxial visco-elastic stress relaxation of the the gore material the em hoop strains increase and the em meridional stresses decrease whereas the em remaining strain and stress components remain substantially unchanged These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission both in terms of the material performance and the overall stability of the shape of the balloon An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter 48 gore pumpkin balloon is presented The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature The results show good correlation with a numerical study using the ABAQUS finite-element package that includes a widely used model of

  18. Aerial Deployment and Inflation System for Mars Helium Balloons

    Science.gov (United States)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  19. Per-oral endoscopic myotomy: major advance in achalasia treatment and in endoscopic surgery.

    Science.gov (United States)

    Friedel, David; Modayil, Rani; Stavropoulos, Stavros N

    2014-12-21

    Per-oral endoscopic myotomy (POEM) represents a natural orifice endoscopic surgery (NOTES) approach to laparoscopy Heller myotomy (LHM). POEM is arguably the most successful clinical application of NOTES. The growth of POEM from a single center in 2008 to approximately 60 centers worldwide in 2014 with several thousand procedures having been performed attests to the success of POEM. Initial efficacy, safety and acid reflux data suggest at least equivalence of POEM to LHM, the previous gold standard for achalasia therapy. Adjunctive techniques used in the West include impedance planimetry for real-time intraprocedural luminal assessment and endoscopic suturing for challenging mucosal defect closures during POEM. The impact of POEM extends beyond the realm of esophageal motility disorders as it is rapidly popularizing endoscopic submucosal dissection in the West and spawning offshoots that use the submucosal tunnel technique for a host of new indications ranging from resection of tumors to pyloromyotomy for gastroparesis.

  20. Comparison of Endoscopic Variceal Ligation and Endoscopic Variceal Obliteration in Patients with GOV1 Bleeding

    OpenAIRE

    Hong, Hyoung Ju; Jun, Chung Hwan; Lee, Du Hyeon; Cho, Eun Ae; Park, Seon Young; Cho, Sung Bum; Park, Chang Hwan; Joo, Young Eun; Kim, HyunSoo; Choi, Sung Kyu; Rew, Jong Sun

    2013-01-01

    The aim of this study was to compare the efficacy, rebleeding rates, survival, and complications of endoscopic variceal ligation (EVL) with those of endoscopic variceal obliteration (EVO) in patients with acute type 1 gastroesophageal variceal (GOV1) bleeding. Data were collected retrospectively at a single center. A total of 84 patients were selected (20 patients underwent EVL; 64 patients underwent EVO) from February 2004 to September 2011. Their clinical characteristics, laboratory results...

  1. Endoscopic Management of an Intramural Sinus Leak After Per- Oral Endoscopic Myotomy

    OpenAIRE

    Al Taii, Haider; Confer, Bradley; Gabbard, Scott; Kroh, Matthew; Jang, Sunguk; Rodriguez, John; Parsi, Mansour A.; Vargo, John J.; Ponsky, Jeffrey; Bhatt, Amit

    2016-01-01

    Per-oral endoscopic myotomy (POEM) was developed less than a decade ago for the treatment of achalasia. Its minimally invasive approach and the favorable short-term outcome have led to rapid adoption of the technique throughout the world. As with any new technique, there will be adverse events, and it is important that effective treatments for these adverse events be discussed. We present a case of successful endoscopic management of an intramural sinus leak after a POEM procedure using tande...

  2. Balloon Occlusion of the Contralateral Iliac Artery to Assist Recanalization of the Ipsilateral Iliac Artery in Total Aortoiliac Occlusion: A Technical Note

    Directory of Open Access Journals (Sweden)

    Abdel Aziz A. Jaffan

    2013-01-01

    Full Text Available Endovascular recanalization of chronic total aortoiliac occlusion is technically challenging. Inability to reenter the true aortic lumen, following retrograde iliac recanalization, is one of the most common causes of failure. We describe a case of a total aortoiliac occlusion where balloon occlusion of the right common iliac artery, following its recanalization from a brachial approach, was used to facilitate antegrade recanalization of the occluded contralateral left common iliac artery.

  3. Systematic Review of Endoscopic Middle Ear Surgery Outcomes

    Science.gov (United States)

    Kozin, Elliott D.; Gulati, Shawn; Lehmann, Ashton; Remenschneider, Aaron K.; Kaplan, Alyson; Landegger, Lukas D.; Cohen, Michael S.; Lee, Daniel J.

    2015-01-01

    Objective Middle ear surgery increasingly employs endoscopes as an adjunct to or replacement for the operative microscope. Superior visualization and transcanal access to disease normally managed with a transmastoid approach are touted as advantages with the endoscope. No study, however, has systemically reviewed the literature to evaluate outcomes of endoscopic ear surgery (EES). We provide a systematic review of endoscope applications in middle ear surgery with an emphasis on outcomes. Data Sources PubMed, Embase, and Cochrane Methods A literature review was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis recommendations. Articles were categorized based on study design, indication, and use of an endoscope either as an adjunct to or as a replacement for a microscope. Quantitative and descriptive analyses were performed. Results Ninety-one articles published between 1967 and 2014 met inclusion and exclusion criteria. The main indication for the use of an endoscope was cholesteatoma or myringoplasty. Of the identified articles, 40 provided a discrete discussion of outcomes. In cholesteatoma surgery, the endoscope has been mainly employed as an adjunct to the microscope, and although outcomes assessments vary across studies, the endoscope identified residual cholesteatoma in up to 50% of cases. Conclusion Endoscopes have been predominately used as an observational adjunct to the microscope to improve visualization of the tympanic cavity. Recent reports utilize the endoscope exclusively during surgical dissection; however, data comparing patient outcomes following the use of an operative endoscope versus a microscope are lacking. Areas in need of additional research are highlighted. PMID:25418475

  4. High n ballooning modes in highly elongated tokamaks

    International Nuclear Information System (INIS)

    An, C.H.; Bateman, G.

    1980-02-01

    An analytic study of stability against high n ballooning modes in highly elongated axisymmetric plasmas is presented and compared with computational results. From the equation for the marginal pressure gradient, it is found that the local shear plays an important role on the stability of elongated and shifted plasma, and that high elongation deteriorates the stability by decreasing the stabilizing effects of field line bending and local shear. The net contribution of the local shear to stability decreases with elongation and shift for strongly ballooning modes (eigenfunctions strongly localized near the outer edge of the toroidal flux surfaces) but increases for interchange modes (eigenfunctions more uniform along the flux surfaces). The computational study of high n ballooning modes in a highly elongated plasma reveals that lowering the aspect ratio and broadening the pressure profile enhance the marginal beta for β/sub p/ less than unity but severely reduce the marginal beta for β/sub p/ larger than unity

  5. Review of the British scientific sounding rocket and balloon programmes

    International Nuclear Information System (INIS)

    Delury, J.T.

    1978-01-01

    This review describes the UK scientific sounding rocket programmes which have utilised Skylarks for 21 years, Petrels for 10 years and Fulmars for 2 years. The SRC's ongoing programme is now based on the Petrel and Fulmar rockets, and approved proposals by 5 UK scientific groups covering 1978 and 1979 are outlined. The British scientific balloon programme, which serves 14 scientific groups within UK universities, involves a planned 10 flights per annum using balloons of 3 M cu ft to 31 M cu ft capacity and payloads up to 2 tons in weight. The review outlines the balloon programme of flights planned mainly from Palestine in Texas and Alice Springs/Mildura in Australia. (author)

  6. Popping balloons: formation of a crack network in rubber membranes

    Science.gov (United States)

    Moulinet, Sebastien; Adda-Bedia, Mokhtar; Equipe Morphogenèse et phénomènes multi-échelle Team

    2015-03-01

    Everyone can make the observation: a rubber balloon inflated until it spontaneously pop breaks into a large number of shreds. In contrast, a balloon pierced with a needle at an early stage of its inflation breaks into two large pieces. Using model latex balloons, we have experimentally investigated the transition between these two breaking regimes. We have showed that, above a threshold stress in the latex membrane, a single crack become unstable and separates into two new cracks. Then, a cascade of tip-splitting generates a network of cracks that eventually form a large number of fragments. We have observed that the instability of the crack occurs when it reaches a limit velocity that could the speed of sound. By studying the energy balance during the explosion, we can determine the intrinsic fracture energy of rubber, a measurement difficult to achieve with usual tensile testing.

  7. JUBA (Joint UAS-Balloon Activities) Final Campaign Report.

    Energy Technology Data Exchange (ETDEWEB)

    Dexheimer, Darielle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Apple, Monty [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Callow, Diane Schafer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Longbottom, Casey Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Novick, David K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wilson, Christopher W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, JUBA was a collaborative exercise between SNL Orgs. 6533 & 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and UAS on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the ARM AMF3 site at Oliktok Point, Alaska. The Restricted Airspace occupies a 2 nautical mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 – 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability.

  8. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients

    DEFF Research Database (Denmark)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik

    2015-01-01

    , and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess...... if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected...... patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction...

  9. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    Science.gov (United States)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  10. Iridium: Global OTH data communications for high altitude scientific ballooning

    Science.gov (United States)

    Denney, A.

    While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several

  11. Evaluation of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope

    Science.gov (United States)

    Yoshimoto, Kayo; Watabe, Kenji; Fujinaga, Tetsuji; Iijima, Hideki; Tsujii, Masahiko; Takahashi, Hideya; Takehara, Tetsuo; Yamada, Kenji

    2017-02-01

    Because the view angle of the endoscope is narrow, it is difficult to get the whole image of the digestive tract at once. If there are more than two lesions in the digestive tract, it is hard to understand the 3D positional relationship among the lesions. Virtual endoscopy using CT is a present standard method to get the whole view of the digestive tract. Because the virtual endoscopy is designed to detect the irregularity of the surface, it cannot detect lesions that lack irregularity including early cancer. In this study, we propose a method of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope. The method is as follows: 1) capture sequential images of the digestive tract by moving the endoscope, 2) reconstruct 3D surface pattern for each frame by stereo images, 3) estimate the position of the endoscope by image analysis, 4) reconstitute the entire image of the digestive tract by combining the 3D surface pattern. To confirm the validity of this method, we experimented with a straight tube inside of which circles were allocated at equal distance of 20 mm. We captured sequential images and the reconstituted image of the tube revealed that the distance between each circle was 20.2 +/- 0.3 mm (n=7). The results suggest that this method of endoscopic entire 3D image acquisition may help us understand 3D positional relationship among the lesions such as early esophageal cancer that cannot be detected by virtual endoscopy using CT.

  12. Preventing hairline elevation in endoscopic browlifts.

    Science.gov (United States)

    Hamas, R S; Rohrich, R J

    1997-04-01

    An endoscopic-assisted method of brow elevation using galea aponeurosis plication with direct suture fixation is presented. This technique does not elevate the hairline, nor is any skin or scalp resected. Dissection is easy because it is limited to the subgaleal plane of the forehead.

  13. Upper gastrointestinal endoscopic findings and prevalence of ...

    African Journals Online (AJOL)

    Upper gastrointestinal endoscopic findings and prevalence of Helicobacter pylori infection among adult patients with dyspepsia in northern Tanzania. ... Endoscopy (EGD) for initial work up. Study on antimicrobial susceptibility pattern of H. pylori is recommended to guide choices for evidence based treatment option.

  14. Oesophageal cancer and experience with endoscopic stent ...

    African Journals Online (AJOL)

    Background: Oesophageal cancer often presents in advanced stages not amenable to surgical resection. In such patients, palliation of dysphagia remains the mainstay of management. oBjectives: To determine the burden of advanced oesophageal cancer and to document the experience with endoscopic metal stent.

  15. Early endoscopic realignment in posterior urethral injuries.

    Science.gov (United States)

    Shrestha, B; Baidya, J L

    2013-01-01

    Posterior urethral injury requires meticulous tertiary care and optimum expertise to manage successfully. The aim of our study is to describe our experiences with pelvic injuries involving posterior urethra and their outcome after early endoscopic realignment. A prospective study was carried out in 20 patients with complete posterior urethral rupture, from November 2007 till October 2010. They presented with blunt traumatic pelvic fracture and underwent primary realignment of posterior urethra in our institute. The definitive diagnosis of urethral rupture was made after retrograde urethrography and antegrade urethrography where applicable. The initial management was suprapubic catheter insertion after primary trauma management in casualty. After a week of conservative management with intravenous antibiotics and pain management, patients were subjected to the endoscopic realignment. The follow up period was at least six months. The results were analyzed with SPSS software. After endoscopic realignment, all patients were advised CISC for the initial 3 months. All patients voided well after three months of CISC. However, 12 patients were lost to follow up by the end of 6 postoperative months. Out of eight remaining patients, two had features of restricture and were managed with DVU followed by CISC again. One patient with restricture had some degree of erectile dysfunction who improved significantly after phospodiesterase inhibitors. None of the patients had features of incontinence. Early endoscopic realignment of posterior urethra is a minimally invasive modality in the management of complete posterior urethral injury with low rates of incontinence and impotency.

  16. Update on the endoscopic treatments for achalasia.

    Science.gov (United States)

    Uppal, Dushant S; Wang, Andrew Y

    2016-10-21

    Achalasia is the most common primary motility disorder of the esophagus and presents as dysphagia to solids and liquids. It is characterized by impaired deglutitive relaxation of the lower esophageal sphincter. High-resolution manometry allows for definitive diagnosis and classification of achalasia, with type II being the most responsive to therapy. Since no cure for achalasia exists, early diagnosis and treatment of the disease is critical to prevent end-stage disease. The central tenant of diagnosis is to first rule out mechanical obstruction due to stricture or malignancy, which is often accomplished by endoscopic and fluoroscopic examination. Therapeutic options include pneumatic dilation (PD), surgical myotomy, and endoscopic injection of botulinum toxin injection. Heller myotomy and PD are more efficacious than pharmacologic therapies and should be considered first-line treatment options. Per oral endoscopic myotomy (POEM) is a minimally-invasive endoscopic therapy that might be as effective as surgical myotomy when performed by a trained and experienced endoscopist, although long-term data are lacking. Overall, therapy should be individualized to each patient's clinical situation and based upon his or her risk tolerance, operative candidacy, and life expectancy. In instances of therapeutic failure or symptom recurrence re-treatment is possible and can include PD or POEM of the wall opposite the site of prior myotomy. Patients undergoing therapy for achalasia require counseling, as the goal of therapy is to improve swallowing and prevent late manifestations of the disease rather than to restore normal swallowing, which is unfortunately impossible.

  17. Liver parenchumography following endoscopic retrograde cholangiopancreatography (ERCP)

    International Nuclear Information System (INIS)

    Revert, A.; Arana, E.; Pertejo, V.; Berenguer, M.; Masip, M.J.

    1998-01-01

    Focal liver opacification during endoscopic retrograde cholangiography (ERCP) is an uncommon complication caused by excessive pressure during contrast injection. In this situation, ERCP must be interrupted and the position of the cannula checked. We recommend that these images be excluded from the diagnosis of tumor or cystic cavities. 4 refs

  18. Endoscopic management of bile leaks after laparoscopic ...

    African Journals Online (AJOL)

    2013-11-04

    Nov 4, 2013 ... 1 required mesh repair of a large incisional hernia. Discussion. In this study, three-quarters of postoperative bile leaks were suitable for endoscopic management and were treated with combinations of ES and bile duct ... is more rapid in dogs with stents compared with sphincterotomy alone.[8,10,18,19] The.

  19. Endoscopic Third Ventriculostomy: Success and Failure.

    Science.gov (United States)

    Deopujari, Chandrashekhar E; Karmarkar, Vikram S; Shaikh, Salman T

    2017-05-01

    Endoscopic third ventriculostomy (ETV) has now become an accepted mode of hydrocephalus treatment in children. Varying degrees of success for the procedure have been reported depending on the type and etiology of hydrocephalus, age of the patient and certain technical parameters. Review of these factors for predictability of success, complications and validation of success score is presented.

  20. Peroral Endoscopic Myotomy: Establishing a New Program

    Science.gov (United States)

    Kumta, Nikhil A.; Mehta, Shivani; Kedia, Prashant; Weaver, Kristen; Sharaiha, Reem Z.; Fukami, Norio; Minami, Hitomi; Casas, Fernando; Gaidhane, Monica; Lambroza, Arnon

    2014-01-01

    Achalasia is an esophageal motility disorder characterized by incomplete relaxation of the lower esophageal sphincter (LES) and aperistalsis of the esophageal body. Treatment of achalasia is aimed at decreasing the resting pressure in the LES. Peroral endoscopic myotomy (POEM), derived from natural orifice transluminal endoscopic surgery (NOTES) and advances in endoscopic submucosal dissection (ESD), presents a novel, minimally invasive, and curative endoscopic treatment for achalasia. POEM involves an esophageal mucosal incision followed by creation of a submucosal tunnel crossing the esophagogastric junction and myotomy before closure of the mucosal incision. Although the procedure is technically demanding and requires a certain degree of skill and competency, treatment success is high (90%) with low complication rates. Since the first described POEM in humans in 2010, it has been used increasingly at centers worldwide. This article reviews available published clinical studies demonstrating POEM efficacy and safety in order to present a proposal on how to establish a dedicated POEM program and reach base proficiency for the procedure. PMID:25324996

  1. Endoscopic third ventriculostomy and choroid plexus cauterization ...

    African Journals Online (AJOL)

    Background: Endoscopic third ventriculostomy (ETV) and Choroid Plexus Cauterization (CPC) have been recommended as reliable surgical options in developing countries for childhood hydrocephalus owing to reported shunt failures in shunt dependency. Objective: To evaluate outcomes of the ETV and ETV-CPC ...

  2. An illumination system for endoscopic applications

    DEFF Research Database (Denmark)

    2013-01-01

    The present disclosure relates to an illumination system for endoscopic applications comprising at least one substantially monochromatic light source having a predefined central wavelength between 400 and 500 nm or between 500 and 550 nm, an optical transmission path adapted to guide light emanat...... for photodynamic diagnosis and/or therapy of bladder cancer is further disclosed herein....

  3. Esophageal Stricture Post Endoscopic Injection Sclerotherapy ...

    African Journals Online (AJOL)

    Only two patients had esophageal varices secondary to viral hepatitis B liver cirrhosis. Their presentation was commonly with difficulty in swallowing and few cases presented with food impaction. The majority of patients were treated with wire guided endoscopic Savary Gilliard dilation. Conclusion: Esophageal stricture ...

  4. Oesophageal cancer and experience with endoscopic stent ...

    African Journals Online (AJOL)

    Background: Oesophageal cancer often presents in advanced stages not amenable to surgical resection. In such patients, palliation of dysphagia remains the mainstay of management. Objectives: To determine the burden of advanced oesophageal cancer and to document the experience with endoscopic metal stent ...

  5. Endoscopic surgery simulation in a virtual environment

    NARCIS (Netherlands)

    Dumay, A.C.M.; Jense, G.J.

    1995-01-01

    The minimally invasive nature of endoscopic surgery allows operations to be performed on patients through small incisions, often under local anaesthesia. Patient recovery times and cosmetic detriment are thus greatly reduced, while overall quality of care is improved. Presently, surgeons are trained

  6. Successful Endoscopic Therapy of Traumatic Bile Leaks

    Directory of Open Access Journals (Sweden)

    Matthew P. Spinn

    2013-02-01

    Full Text Available Traumatic bile leaks often result in high morbidity and prolonged hospital stay that requires multimodality management. Data on endoscopic management of traumatic bile leaks are scarce. Our study objective was to evaluate the efficacy of the endoscopic management of a traumatic bile leak. We performed a retrospective case review of patients who were referred for endoscopic retrograde cholangiopancreatography (ERCP after traumatic bile duct injury secondary to blunt (motor vehicle accident or penetrating (gunshot trauma for management of bile leaks at our tertiary academic referral center. Fourteen patients underwent ERCP for the management of a traumatic bile leak over a 5-year period. The etiology included blunt trauma from motor vehicle accident in 8 patients, motorcycle accident in 3 patients and penetrating injury from a gunshot wound in 3 patients. Liver injuries were grade III in 1 patient, grade IV in 10 patients, and grade V in 3 patients. All patients were treated by biliary stent placement, and the outcome was successful in 14 of 14 cases (100%. The mean duration of follow-up was 85.6 days (range 54-175 days. There were no ERCP-related complications. In our case review, endoscopic management with endobiliary stent placement was found to be successful and resulted in resolution of the bile leak in all 14 patients. Based on our study results, ERCP should be considered as first-line therapy in the management of traumatic bile leaks.

  7. Endoscopic treatment of vesicoureteral reflux: Current status

    Directory of Open Access Journals (Sweden)

    Goran Lackgren

    2009-01-01

    Full Text Available Vesicoureteral reflux (VUR affects around 1% of all children. It carries an increased risk of febrile urinary tract infections (UTIs and is associated with impaired renal function. Endoscopic treatment with NASHA/Dx gel (dextranomer microspheres in a stabilized hyaluronic acid-based gel of nonanimal origin is minimally invasive, well tolerated and provides cure rates approaching those of open surgery: ~90% in several studies. It has also been shown to be effective in a variety of ′complicated′ cases. Endoscopic treatment is therefore considered preferable to open surgery and long-term antibiotic prophylaxis. Nontreatment of VUR is being discussed as an alternative option, whereby children are treated with antibiotics only when UTIs occur. Considering all the available evidence, however, active intervention with endoscopic treatment remains preferable. A new approach to managing VUR may nevertheless be considered, with treatment decisions based not only on the grade of reflux, but also factors such as age, sex, renal scarring, and bladder dysfunction. Open surgery would be reserved for use only in the ~10% of children not responding to endoscopic treatment, and patients with refluxing primary megaureter.

  8. Subcutaneous endoscopically assisted ligation using miniport for ...

    African Journals Online (AJOL)

    Background This report describes the first miniport method using subcutaneous endoscopically assisted ligation (SEAL) for the treatment of girls with inguinal hernia. To validate its safety and efficacy, the authors evaluated their early experiences. Methods Between April 2014 and December 2014, 19 SEALs using miniport ...

  9. Optimization of portal placement for endoscopic calcaneoplasty

    NARCIS (Netherlands)

    van Sterkenburg, Maayke N.; Groot, Minke; Sierevelt, Inger N.; Spennacchio, Pietro A.; Kerkhoffs, Gino M. M. J.; van Dijk, C. Niek

    2011-01-01

    The purpose of our study was to determine an anatomic landmark to help locate portals in endoscopic calcaneoplasty. The device for optimal portal placement (DOPP) was developed to measure the distance from the distal fibula tip to the calcaneus (DFC) in 28 volunteers to determine the location of the

  10. Endoscopic Surgery for Traumatic Acute Subdural Hematoma

    Directory of Open Access Journals (Sweden)

    Hiroyuki Kon

    2014-01-01

    Full Text Available Traumatic acute subdural hematoma (ASDH is generally addressed by craniotomy under general anesthesia. We report a patient whose traumatic ASDH was treated under local anesthesia by one-burr-hole endoscopic surgery. This 87-year-old woman had undergone coil embolization for a ruptured right middle-cerebral artery aneurysm and placement of a ventriculoperitoneal shunt for normal pressure hydrocephalus 5 years earlier. Upon admission, she manifested consciousness disturbance after suffering head trauma and right hemiplegia. Her Glasgow Coma Scale score was 8 (E2V2M4. Computed tomography (CT demonstrated a thick, left-frontotemporal ASDH. Due to her advanced age and poor condition, we performed endoscopic surgery rather than craniotomy to evacuate the ASDH. Under local anesthesia, we made a burr hole in her left forehead and increased its size to 15 mm in diameter. After introducing a transparent sheath into the hematoma cavity with a rigid endoscope, the clot was evacuated with a suction tube. The arterial bleeding point was electrically coagulated. A postoperative CT scan confirmed the reduction of the hematoma. There was neither brain compression nor brain swelling. Her consciousness disturbance and right hemiplegia improved immediately. Endoscopic surgery may represent a viable method to address traumatic intracranial hematomas in some patients.

  11. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  12. Particle Astrophysics in NASA's Long Duration Balloon Program

    Energy Technology Data Exchange (ETDEWEB)

    Gorham, Peter W.

    2013-10-15

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons.

  13. Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.

    Science.gov (United States)

    Ro, Andrew J; Davé, Vipul

    2013-03-01

    Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. AIAA Educator Academy: The Space Weather Balloon Module

    Science.gov (United States)

    Longmier, B.; Henriquez, E.; Bering, E. A.; Slagle, E.

    2013-12-01

    Educator Academy is a K-12 STEM curriculum developed by the STEM K-12 Outreach Committee of the American Institute of Aeronautics and Astronautics (AIAA). Consisting of three independent curriculum modules, K-12 students participate in inquiry-based science and engineering challenges to improve critical thinking skills and enhance problem solving skills. The Space Weather Balloon Curriculum Module is designed for students in grades 9-12. Throughout this module, students learn and refine physics concepts as well as experimental research skills. Students participate in project-based learning that is experimental in nature. Students are engaged with the world around them as they collaborate to launch a high altitude balloon equipped with HD cameras.The program leaders launch high altitude weather balloons in collaboration with schools and students to teach physics concepts, experimental research skills, and to make space exploration accessible to students. A weather balloon lifts a specially designed payload package that is composed of HD cameras, GPS tracking devices, and other science equipment. The payload is constructed and attached to the balloon by the students with low-cost materials. The balloon and payload are launched with FAA clearance from a site chosen based on wind patterns and predicted landing locations. The balloon ascends over 2 hours to a maximum altitude of 100,000 feet where it bursts and allows the payload to slowly descend using a built-in parachute. The payload is located using the GPS device. In April 2012, the Space Weather Balloon team conducted a prototype field campaign near Fairbanks Alaska, sending several student-built experiments to an altitude of 30km, underneath several strong auroral displays. To better assist teachers in implementing one or more of these Curriculum Modules, teacher workshops are held to give teachers a hands-on look at how this curriculum is used in the classroom. And, to provide further support, teachers are each

  15. Cloud Water Content Sensor for Sounding Balloons and Small UAVs

    Science.gov (United States)

    Bognar, John A.

    2009-01-01

    A lightweight, battery-powered sensor was developed for measuring cloud water content, which is the amount of liquid or solid water present in a cloud, generally expressed as grams of water per cubic meter. This sensor has near-zero power consumption and can be flown on standard sounding balloons and small, unmanned aerial vehicles (UAVs). The amount of solid or liquid water is important to the study of atmospheric processes and behavior. Previous sensing techniques relied on strongly heating the incoming air, which requires a major energy input that cannot be achieved on sounding balloons or small UAVs.

  16. Cosmic ray abundance measurements with the CAKE balloon experiment

    CERN Document Server

    Cecchini, S.; Giacomelli, G.; Manzoor, S.; Medinaceli, E.; Patrizii, L.; Togo, V.

    2005-01-01

    We present the results from the CAKE (Cosmic Abundance below Knee Energy) balloon experiment which uses nuclear track detectors. The final experiment goal is the determination of the charge spectrum of CR nuclei with Z $>$ 30 in the primary cosmic radiation. The detector, which has a geometric acceptance of $\\sim$ 1.7 m$^2$sr, was exposed in a trans-mediterranean stratospheric balloon flight. Calibrations of the detectors used (CR39 and Lexan), scanning strategies and algorithms for tracking particles in an automatic mode are presented. The present status of the results is discussed

  17. Polymer blends for LDB applications. [Long Duration Ballooning

    Science.gov (United States)

    Lichkus, Andrew M.; Harrison, Ian R.

    1991-01-01

    A series of LCP/PE blends have been studied to determine the potential of such systems to produce a high modulus balloon film material which retains the balloon fabrication and low temperature flight advantages of the current PE films. Blown films of blends of 5 and 15 percent LCP in PE have been produced which show a 28 percent enhancement in modulus over the neat PE matrix. These results are substantially lower than anticipated and are explained in terms of the LCP reinforcement aspect ratio and fibril diameter.

  18. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  19. The German scientific balloon and sounding rocket programme

    International Nuclear Information System (INIS)

    Dahl, A.F.

    1980-01-01

    This report contains information on sounding rocket projects in the scientific field of astronomy, aeronomy, magnetosphere, and material science under microgravity. The scientific balloon projects are performed with emphasis on astronomical research. By means of tables it is attempted to give a survey, as complete as possible, of the projects the time since the last symposium in Ajaccio, Corsica, and of preparations and plans for the future until 1983. The scientific balloon and sounding rocket projects form a small successful part of the German space research programme. (Auth.)

  20. Endoscopic suturing versus endoscopic clip closure of the mucosotomy during a per-oral endoscopic myotomy (POEM): a case-control study.

    Science.gov (United States)

    Pescarus, Radu; Shlomovitz, Eran; Sharata, Ahmed M; Cassera, Maria A; Reavis, Kevin M; Dunst, Christy M; Swanström, Lee L

    2016-05-01

    Obtaining an adequate mucosal closure is one of the crucial steps in per-oral endoscopic myotomy (POEM). Thus far, there have been no objective data comparing the various available closure techniques. This case-controlled study attempts to compare the application of endoscopic clips versus endoscopic suturing for mucosotomy closure during POEM cases. A retrospective review of our prospective POEM database was performed. All cases in which endoscopic suturing was used to close the mucosotomy were matched to cases in which standard endoclips were used. Overall complication rate, closure time and mucosal closure costs between the two groups were compared. Both techniques offer good clinical results with good mucosal closure and the absence of postoperative leak. Closure time was significantly shorter (p = 0.044) with endoscopic clips (16 ± 12 min) when compared to endoscopic suturing (33 ± 11 min). Overall, the total closure cost analysis showed a trend toward lower cost with clips (1502 ± 849 USD) versus endoscopic suturing (2521 ± 575 USD) without reaching statistical significance (p = 0.073). The use of endoscopic suturing seems to be a safe method for mucosal closure in POEM cases. Closure time is longer with suturing than conventional closure with clips, and there is a trend toward higher overall cost. Endoscopic suturing is likely most cost-effective for difficult cases where conventional closure methods fail.

  1. Endoscopic sleeve gastroplasty: the learning curve.

    Science.gov (United States)

    Hill, Christine; El Zein, Mohamad; Agnihotri, Abhishek; Dunlap, Margo; Chang, Angela; Agrawal, Alison; Barola, Sindhu; Ngamruengphong, Saowanee; Chen, Yen-I; Kalloo, Anthony N; Khashab, Mouen A; Kumbhari, Vivek

    2017-09-01

    Endoscopic sleeve gastroplasty (ESG) is gaining traction as a minimally invasive bariatric treatment. Concern that the learning curve may be slow, even among those proficient in endoscopic suturing, is a barrier to widespread implementation of the procedure. Therefore, we aimed to define the learning curve for ESG in a single endoscopist experienced in endoscopic suturing who participated in a 1-day ESG training program.  Consecutive patients who underwent ESG between February 2016 and November 2016 were included. The performing endoscopist, who is proficient in endoscopic suturing for non-ESG procedures, participated in a 1-day ESG training session before offering ESG to patients. The outcome measurements were length of procedure (LOP) and number of plications per procedure. Nonlinear regression was used to determine the learning plateau and calculate the learning rate.  Twenty-one consecutive patients (8 males), with mean age 47.7 ± 11.2 years and mean body mass index 41.8 ± 8.5 kg/m 2 underwent ESG. LOP decreased significantly across consecutive procedures, with a learning plateau at 101.5 minutes and a learning rate of 7 cases ( P  = 0.04). The number of plications per procedure also decreased significantly across consecutive procedures, with a plateau at 8 sutures and a learning rate of 9 cases ( P  < 0.001). Further, the average time per plication decreased significantly with consecutive procedures, reaching a plateau at 9 procedures ( P  < 0.001).  Endoscopists experienced in endoscopic suturing are expected to achieve a reduction in LOP and number of plications per procedure in successive cases, with progress plateauing at 7 and 9 cases, respectively.

  2. Endoscopic management of biliary injuries and leaks

    Directory of Open Access Journals (Sweden)

    T S Chandrasekar

    2012-01-01

    Full Text Available Bile duct injuries and subsequent leaks can occur following laparoscopic and open cholecystectomies and also during other hepatobiliary surgeries. Various patient related and technical factors are implicated in the causation of biliary injuries. Over a period of twenty five years managing such patients of biliary injuries our team has found a practical approach to assess the cause of biliary injuries based on the symptoms, clinical examination and imaging. Bismuth classification is helpful in most of the cases. Immediate referral to a centre experienced in the management of bile duct injury and timely intervention is associated with improved outcomes. Resuscitation, correcting dyselectrolytemia, aspiration of undrained biloma and antibiotics take the priority in the management. The goal is to restore the bile conduit, and to prevent short and longterm complications such as biliary fistula, intra-abdominal abscess, biliary stricture, recurrent cholangitis and secondary biliary cirrhosis. Endoscopic therapy by reducing the transpapillary pressure gradient helps in reducing the leak. Endoscopic therapy with biliary sphincterotomy alone or with additional placement of a biliary stent/ nasobiliary drainage is advocated. In our tertiary care referral unit, we found endoscopic interventions are useful in situations where there is leak with associated CBD calculus or a foreign body, peripheral bile duct injury, cystic duct stump leak and partial bile duct injury with leak/ narrowing of the lumen. Endotherapy is not useful in case of complete transection (total cut off and complete stricture involving common hepatic or common bile ducts. In conclusion, endoscopic treatment can be considered a highly effective therapy and should be the first-line therapy in such patients. Though less successful, an endoscopic attempt is warranted in patients suffering from central bile duct leakages failing which surgical management is recommended.

  3. Radiological findings after endoscopic incision of ureterocele

    International Nuclear Information System (INIS)

    Cheon, Jung Eun; Kim, In One; Seok, Eul Hye; Cha, Joo Hee; Choi, Gook Myung; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Kwang Myung; Choi, Hwang; Cheon, Jung Eun; Seok, Eul Hye; Cha, Joo Hee; Choi, Guk Myung

    2001-01-01

    Endoscopic incision of ureterocele is considered a simple and safe method for decompression of urinary tract obstruction above ureterocele. The purpose of this study was to evaluate the radiological findings after endoscopic incision of ureterocele. We retrospectively reviewed the radiological findings (ultrasonography (US), intravenous urography, and voiding cystourethrography(VCU)) in 16 patients with ureterocele who underwent endoscopic incision (mean age at surgery, 15 months; M:F 3:13; 18 ureteroceles). According to the postoperative results, treatment was classified as successful when medical treatment was still required, and second operation when additional surgical treatment was required. Postoperative US (n=10) showed that in all patients, urinary tract obstruction was relieved: the kidney parenchima was thicker and the ureterocele was smaller. Intravenous urography (n=8), demonstrated that in all patients, urinary tract obstruction and the excretory function of the kidney had improved. Postoperative VCU indicated that in 92% of patients (12 of 13), endoscopic incision of the ureterocele led to vesicoureteral reflux(VUR). Of these twelve, seven (58%) showed VUR of more than grade 3, while newly developed VUR was seen in five of eight patients (63%) who had preoperative VCU. Surgery was successful in four patients (25%), partially successful in three (19%), and a second operation-on account of recurrent urinary tract infection and VUR of more than grase 3 during the follow-up period-was required by nine (56%). Although endoscopic incision of a ureterocele is a useful way of relieving urinary tract obstruction, an ensuing complication may be VUR. Postoperative US and intravenous urography should be used to evaluate parenchymal change in the kidney and improvement of uronary tract obstructon, while to assess the extend of VUR during the follow-up period , postoperative VCU is required

  4. A Simple Technique to Facilitate Treatment of Urethral Strictures with Optical Internal Urethrotomy

    Directory of Open Access Journals (Sweden)

    Konstantinos Stamatiou

    2014-01-01

    Full Text Available Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization, urethroplasty, endoscopic internal urethrotomy, and dilation. Optical internal urethrotomy offers faster recovery, minimal scarring, and less risk of infection, although recurrence is possible. However, technical difficulties associated with poor visualization of the stenosis or of the urethral lumen may increase procedural time and substantially increase the failure rates of internal urethrotomy. In this report we describe a technique for urethral catheterization via a suprapubic, percutaneous approach through the urinary bladder in order to facilitate endoscopic internal urethrotomy.

  5. BioEnterics Intragastric Balloon (BIB) versus Spatz Adjustable Balloon System (ABS): Our experience in the elderly.

    Science.gov (United States)

    Russo, Teresa; Aprea, Giovanni; Formisano, Cesare; Ruggiero, Simona; Quarto, Gennaro; Serra, Raffaele; Massa, Guido; Sivero, Luigi

    2017-02-01

    The BioEnterics Intragastric Balloon (BIB) and the Spatz Adjustable Balloon System (ABS) are in fact recommended for weight reduction as a bridge to bariatric surgery. We retrospected studied patients with body mass index (BMI) and age ranges of 37-46 and 70-80 years, respectively, who had undergone BIB from January 2010 to July 2012 and prospected studied patients who had undergone Spatz balloon from July 2012 to August 2014. The aim of this study is to compare BIB and Spatz in terms of weight loss, complications, and maintenance of weight after removal. For both procedures, the median weight loss was 20 ± 3 kg, median BMI at the end of the therapy was 32 ± 2, and no severe complication occurred. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Early effectiveness of endoscopic posterior urethra primary alignment.

    Science.gov (United States)

    Kim, Fernando J; Pompeo, Alexandre; Sehrt, David; Molina, Wilson R; Mariano da Costa, Renato M; Juliano, Cesar; Moore, Ernest E; Stahel, Philip F

    2013-08-01

    Posterior urethra primary realignment (PUPR) after complete transection may decrease the gap between the ends of the transected urethra, tamponade the retropubic bleeding, and optimize urinary drainage without the need of suprapubic catheter facilitating concurrent pelvic orthopedic and trauma procedures. Historically, the distorted anatomy after pelvic trauma has been a major surgical challenge. The purpose of the study was to assess the relationship of the severity of the pelvic fracture to the success of endoscopic and immediate PUPR following complete posterior urethral disruption using the Young-Burgess classification system. A review of our Level I trauma center database for patients diagnosed with pelvic fracture and complete posterior urethral disruption from January 2005 to April 2012 was performed. Pelvic fracture severity was categorized according to the Young-Burgees classification system. Management consisted of suprapubic catheter insertion at diagnosis followed by early urethral realignment when the patient was clinically stable. Failure of realignment was defined as inability to achieve urethral continuity with Foley catheterization. Clinical follow-up consisted of radiologic, pressure studies and cystoscopic evaluation. A total of 481 patients with pelvic trauma from our trauma registry were screened initially, and 18 (3.7%) were diagnosed with a complete posterior urethral disruption. A total of 15 primary realignments (83.3%) were performed all within 5 days of trauma. The success rate of early realignment was 100%. There was no correlation between the type of pelvic ring fracture and the success of PUPR. Postoperatively, 8 patients (53.3%) developed urethral strictures, 3 patients (20.0%) developed incontinence, and 7 patients (46.7%) reported erectile dysfunction after the trauma. The mean follow-up of these patients was 31.8 months. Endoscopic PUPR may be an effective option for the treatment of complete posterior urethral disruption and

  7. Diagnostic and therapeutic utility of double-balloon enteroscopy in children.

    Science.gov (United States)

    Urs, Arun N; Martinelli, Massimo; Rao, Prithviraj; Thomson, Mike A

    2014-02-01

    Diagnostic and therapeutic benefits of double-balloon enteroscopy (DBE) have been documented in adults, with few data available on pediatric patients. We evaluated the diagnostic and therapeutic utility of DBE in children. A prospective assessment of 113 DBE procedures in 58 consecutive children younger than 18 years (36 boys, 22 girls; median age 12.7 years, range 1-18 years) was performed for a variety of suspected small bowel (SB) disorders from January 2008 to August 2012 in a tertiary referral center for pediatric patients. All of the children had undergone upper gastrointestinal endoscopy and ileocolonoscopy. A total of 19 patients had undergone radiological investigations for SB (n = 11 magnetic resonance imaging; n = 5 barium enterography; n = 3 computed tomography) and 54 patients had undergone wireless capsule endoscopy (WCE). The overall median (range) examination time was 92.5 (45-275) minutes. The median (range) estimated insertion length of SB distal to pylorus was 230 (80-450) cm and proximal to ileocecal valve was 80 (5-275) cm. The common indications for DBE were polyposis syndromes (n = 21) and obscure gastrointestinal bleeding (n = 16). The findings included polyps (n = 19), mucosal ulcers and erosions (n = 8), submucosal elevations with white nodules (n = 4), and angioma/angiodysplasia (n = 2). The overall diagnostic yield for SB lesions using DBE was 70.7% (41/58) and for WCE was 77.7% (42/54). Endotherapeutic intervention was successfully used in 46.5% (n = 27/58). The endoscopic, medical, and surgical contributions to change in management by DBE were 72.4% (n = 42/58). Three complications (5.2%) were noted with uneventful recovery. The diagnostic yield of DBE was comparable to WCE, but with the addition of therapeutic possibility and histological yield. We believe this technique could be a valuable addition to existing endoscopic techniques, complementary to WCE, and may be considered as an alternative diagnostic and therapeutic option in the

  8. Visual explorer facilitator's guide

    CERN Document Server

    Palus, Charles J

    2010-01-01

    Grounded in research and practice, the Visual Explorer™ Facilitator's Guide provides a method for supporting collaborative, creative conversations about complex issues through the power of images. The guide is available as a component in the Visual Explorer Facilitator's Letter-sized Set, Visual Explorer Facilitator's Post card-sized Set, Visual Explorer Playing Card-sized Set, and is also available as a stand-alone title for purchase to assist multiple tool users in an organization.

  9. Balloon dilation of the eustachian tube in a cadaver model: technical considerations, learning curve, and potential barriers.

    Science.gov (United States)

    McCoul, Edward D; Singh, Ameet; Anand, Vijay K; Tabaee, Abtin

    2012-04-01

    The surgical management options for eustachian tube dysfunction have historically been limited. The goal of the current study was to evaluate the technical considerations, learning curve, and potential barriers for balloon dilation of the eustachian tube (BDET) as an alternative treatment modality. Prospective preclinical trial of BDET in a cadaver model. A novel balloon catheter device was used for eustachian tube dilation. Twenty-four BDET procedures were performed by three independent rhinologists with no prior experience with the procedure (eight procedures per surgeon). The duration and number of attempts of the individual steps and overall procedure were recorded. Endoscopic examination of the eustachian tube was performed after each procedure, and the surgeon was asked to rate the subjective difficulty on a five-point scale. Successful completion of the procedure occurred in each case. The overall mean duration of the procedure was 284 seconds, and a mean number of 1.15 attempts were necessary to perform the individual steps. The mean subjective procedure difficulty was noted as somewhat easy. Statistically shorter duration and subjectively easier procedure were noted in the second compared to the first half of the series, indicating a favorable learning curve. Linear fissuring within the eustachian tube lumen without submucosal disruption (nine procedures, 37%) and with submucosal disruption (five procedures, 21%) were noted. The significance of these physical findings is unclear. Preclinical testing of BDET is associated with favorable duration, learning curve, and overall ease of completion. Clinical trials are necessary to evaluate safety and efficacy. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. Pneumonia and mortality after percutaneous endoscopic gastrostomy insertion.

    Science.gov (United States)

    Azzopardi, Neville; Ellul, Pierre

    2013-01-01

    Percutaneous endoscopic gastrostomy feeding provides enteral nutrition to patients with neurological dysphagia. Thirty-day mortality rates of 4-26% have been reported, with pneumonia being the common cause post-percutaneous endoscopic gastrostomy insertion. This retrospective analysis of percutaneous endoscopic gastrostomy tube insertions in Malta (January 2008 - June 2010) compares the incidence of pneumonia in patients fed through a nasogastric tube versus in those fed via a percutaneous endoscopic gastrostomy tube. We analyzed the indications, poor prognostic factors and mortality for percutaneous endoscopic gastrostomy insertion. Ninety-seven patients underwent percutaneous endoscopic gastrostomy insertion. Fifty-four patients received nasogastric feeds before percutaneous endoscopic gastrostomy feeds. Patients on nasogastric feeds developed 32 episodes of pneumonia over a total of 7884 days of feeds (1 every 246 days). Patients with percutaneous endoscopic gastrostomy feeds after a period of nasogastric feeds developed 48 pneumonia episodes over 36,238 days (1 every 755 days). Patients with percutaneous endoscopic gastrostomy feeds without previous nasogastric feeds developed 28 pneumonia episodes over 23,983 days (1 every 856 days), and this was statistically significant (χ 2 test p value nasogastric feeds. However, pneumonia is still the major cause of death among percutaneous endoscopic gastrostomy patients.

  11. Management of a large mucosal defect after duodenal endoscopic resection.

    Science.gov (United States)

    Fujihara, Shintaro; Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Masaki, Tsutomu

    2016-08-07

    Duodenal endoscopic resection is the most difficult type of endoscopic treatment in the gastrointestinal tract (GI) and is technically challenging because of anatomical specificities. In addition to these technical difficulties, this procedure is associated with a significantly higher rate of complication than endoscopic treatment in other parts of the GI tract. Postoperative delayed perforation and bleeding are hazardous complications, and emergency surgical intervention is sometimes required. Therefore, it is urgently necessary to establish a management protocol for preventing serious complications. For instance, the prophylactic closure of large mucosal defects after endoscopic resection may reduce the risk of hazardous complications. However, the size of mucosal defects after endoscopic submucosal dissection (ESD) is relatively large compared with the size after endoscopic mucosal resection, making it impossible to achieve complete closure using only conventional clips. The over-the-scope clip and polyglycolic acid sheets with fibrin gel make it possible to close large mucosal defects after duodenal ESD. In addition to the combination of laparoscopic surgery and endoscopic resection, endoscopic full-thickness resection holds therapeutic potential for difficult duodenal lesions and may overcome the disadvantages of endoscopic resection in the near future. This review aims to summarize the complications and closure techniques of large mucosal defects and to highlight some directions for management after duodenal endoscopic treatment.

  12. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  13. Percutaneous transvenous angioplasty of inferior vena cava by balloon dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kyung Suk; Kim, Jae Kyu; Park, Jin Gyun; Kang, Heung Keun; Chung, Hyon De; Kim, Shin Kon; Chung, Sang Young [Chonnam National University College of Medicine, Kwangju (Korea, Republic of)

    1989-10-15

    3 patients with membranous (2 patients) and segmental (1 patient) obstruction of IVC were successfully treated by percutaneous transvenous angioplasty using balloon catheter. Improvements of clinical and radiological findings could be obtained after procedures. Relatively good patency was obtained in all cases without complications. This procedure can be applied safely to membranous or segmental obstructions of IVC and elsewhere in the venous systems.

  14. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  15. Balloon atrial septostomy under echocardiographic guide: case series

    Directory of Open Access Journals (Sweden)

    SM Meraji

    2012-12-01

    Full Text Available Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. However, not all centers performing early arterial switch repairs have abandoned atrial septostomy, even in patients who respond favorably to prostaglandin infusion.Case presentation: In total, eight 1- to 15-day old term neonates admitted in Shahid Rajaee Heart Center in Tehran, Iran from October 2009 to February 2011, with congenital heart diseases were scheduled for balloon atrial septostomy. In six cases the procedure was done exclusively under echocardiographic guidance and in two cases with the help of fluoroscopy. Success was defined as the creation of an atrial septal defect with a diameter equal to or more than 5 mm and ample mobility of its margins.Results: Male sex was predominant (87% and the mean age of the neonates was six days. The diagnosis in all cases was simple transposition of great arteries. The procedure was successful in all patients with any cardiovascular complication.Conclusion: Balloon atrial septostomy is an emergent procedure that can be done safely and effectively under echocardiographic guidance. According to the feasibility of this technique it could be performed fast, safe and effective at bedside, avoiding patient transportation to hemodynamic laboratory or referral center.

  16. Balloon valvuloplasty for severe mitral valve stenosis in pregnancy ...

    African Journals Online (AJOL)

    Balloon valvuloplasties for severe mitral stenosis were performed on 11 pregnant patients with excellent resutts and no complications. The mitral valve area was increased from a mean of 0.9 cnr to 2.1 cnr. There was no clinically significant mitral regurgitation. The pregnancies proceeded normally to delivery at or near tenn, ...

  17. Balloon test project: Cosmic Ray Antimatter Calorimeter (CRAC)

    Science.gov (United States)

    Christy, J. C.; Dhenain, G.; Goret, P.; Jorand, J.; Masse, P.; Mestreau, P.; Petrou, N.; Robin, A.

    1984-01-01

    Cosmic ray observations from balloon flights are discussed. The cosmic ray antimatter calorimeter (CRAC) experiment attempts to measure the flux of antimatter in the 200-600 Mev/m energy range and the isotopes of light elements between 600 and 1,000 Mev/m.

  18. Achilles tests finally nail PWR fuel clad ballooning fears

    International Nuclear Information System (INIS)

    Dore, P.; McMinn, K.

    1992-01-01

    A conclusive series of experiments carried out by AEA Reactor Services at its Achilles rig in the UK has finally allayed fears that fuel clad ballooning is a major safety problem for Sizewell B, Britain's first Pressurized Water Reactor. The experiments are described in this article. (author)

  19. Balloon dilatation of isolated severe tricuspid valve stenosis

    Directory of Open Access Journals (Sweden)

    Rajeev Bhardwaj

    2015-12-01

    Full Text Available Tricuspid valve stenosis is mostly rheumatic in origin. It almost always occurs in association with mitral valve disease. There are only few case reports of isolated tricuspid valve stenosis. We report a case of isolated tricuspid valve stenosis, which was treated with balloon dilatation.

  20. Balloon dilatation of isolated severe tricuspid valve stenosis

    OpenAIRE

    Bhardwaj, Rajeev; Sharma, Rajesh

    2015-01-01

    Tricuspid valve stenosis is mostly rheumatic in origin. It almost always occurs in association with mitral valve disease. There are only few case reports of isolated tricuspid valve stenosis. We report a case of isolated tricuspid valve stenosis, which was treated with balloon dilatation.

  1. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792

  2. [Expansion dilatation balloons for cervical ripening in obstetric practice].

    Science.gov (United States)

    Ducarme, G; Grange, J; Vital, M

    2016-02-01

    During recent decades, mechanical devices have been substituted by pharmacological methods. Their place in the therapeutic arsenal remains important with a renewed obstetrical interest for these devices. Due to a lack of data they are still not recommended as first-line. This review thus attempted to examine the use of expansion dilatation balloons (Foley catheter and double-balloons) to analyze their effectiveness in case of native uterus and previous cesarean section. Twenty-seven clinical trials had compared balloons catheter and prostaglandins in patients without a history of uterine scar. The risk of cesarean section did not differ. Mechanical methods seemed to be more effective in achieving delivery within 24hours, with fewer episodes of excessive uterine contractions, but they necessitated more oxytocin during labor. Ten clinical trials analyzed dilatation balloons in patients with previous cesarean section. More than 70% women had favorable cervical ripening (Bishop score>6), and vaginal delivery was reported between 35 and 70% of patients. The risk of uterine rupture was low between 0.64 and 0.72%, with neither increased risk of severe neonatal and maternal morbidity nor increased risk of infectious morbidity. Mechanical methods are effective and safe for third trimester cervical ripening, mainly in women with previous cesarean section. Potential advantages may include wide availability and reduction of some of the side effects. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. [Efficacy of percutaneous endoscopic gastrostomy in pediatric patients].

    Science.gov (United States)

    Li, Huiwen; Gong, Sitang; Yang, Min; Chen, Peiyu; Xu, Zhaohui; Liang, Cuiping; Fang, Tiefu; Ren, Lu; Liu, Liying; Li, Jiexia; Geng, Lanlan

    2016-02-01

    To analyze the efficacy of percutaneous endoscopic gastrostomy (PEG) in pediatric patients. From October 2011 to October 2014, children in the gastrointestinal ward of Guangzhou Women and Children's Medical Center received PEG or jejunal tube PEG(JET-PEG). The success rate, operation time were recorded. The changes of their weight, enteral nutrition calories and the incidence of pneumonia before and after the first 6 months of operation were compared. Follow-up was conducted until October 2014, the recent and long term complications, the length of indwelling time, the replacement or removal of the tube were recorded, the patients swallowing function or the primary disease's outcomes were observed. Of the 13 cases, 10 were male, 3 were female, their average age was 2 years (range 1.8 months-9 years). We performed PEG for 12 of the patients who had congenital craniofacial problems that led to feeding difficulties or recurrent cough and pneumonia (6/12), or neurological disorders (6/12) with inability to swallow, and in one case JET-PEG was performed, this child suffered from chronic intestinal pseudo-obstruction with vomiting and abdominal distension. The gastrostomy was successful in all the patients through one operation, the average operation time of PEG was (25 ± 3) minutes, JET-PEG was 60 minutes. One local skin infection was noted, no long-term complication occurred. In the first 6 months after operation, all the patients gained weight((5.5-30.5) kg postoperation vs. (3.0-30.0) kg preoperation), and 12 cases' enteral nutrition calories increased (from (209-502) to(272-543) kJ/(kg·d)), the incidence of pneumonia decreased in the children who had recurrent pneumonia before the operation (from (0-1.5) to (0-0.16) per month). Until October 2014, their average length of gastric tube indwelling time was 17.8 months (range 4-36 months). In 4 cases PEG tube was removed when they could eat completely independently, the other 9 needed enteral vein nutrition via PEG

  4. Magnetic resonance evaluation for small bowel strictures in Crohn's disease: comparison with balloon enteroscopy.

    Science.gov (United States)

    Takenaka, Kento; Ohtsuka, Kazuo; Kitazume, Yoshio; Matsuoka, Katsuyoshi; Fujii, Toshimitsu; Nagahori, Masakazu; Kimura, Maiko; Fujioka, Tomoyuki; Araki, Akihiro; Watanabe, Mamoru

    2017-08-01

    Magnetic resonance (MR) imaging is the recommended technique for detection of small bowel lesions in Crohn's disease. We aimed to evaluate the impact of stricture findings obtained by MR imaging on patient outcomes using balloon-assisted enteroscopy (BAE) as a reference. Two hundred Crohn's disease patients undergoing both MR enterocolonography and BAE were prospectively followed up for at least 1 year. The presence of strictures detected by MR enterocolonography was compared with endoscopic findings. Moreover, the relationship between MR findings and surgery was evaluated. The accuracy of MR imaging for detection of small bowel strictures was defined by a sensitivity of 60.6% and a specificity of 93.4%. Major strictures (diameter less than 10 mm or with internal fistula), long strictures (length 10 mm or greater), and prestenotic dilatation were predictors of stricture detection by MR imaging (P = 0.001, 0.017, and 0.002 respectively). Surgery was performed in 31.6% of patients (18 of 57) in the MR-positive-BAE-positive stricture group and in 10.8% of patients (4 of 37) in the MR-negative-BAE-positive stricture group. Multiple regression analysis showed MR-positive-BAE-positive strictures were an independent risk factor for surgery (P = 0.002 at 6 months and P < 0.001 at 1 year). The surgery-free rate in the MR-negative-BAE-positive stricture group was significantly lower than that in nonstricture group at 1 year (P = 0.001). The specificity of MR imaging for detection of small bowel strictures was clinically sufficient, and the MR procedure could detect critical strictures, which was a predictive factor for surgery. But MR-negative-BAE-positive strictures were also associated with an increased risk compared with no strictures after 1 year of follow-up.

  5. Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

    Science.gov (United States)

    Kogut, Alan; James, Bryan; Fixsen, Dale

    2013-01-01

    Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then

  6. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    Science.gov (United States)

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  7. National Report on the NASA Sounding Rocket and Balloon Programs

    Science.gov (United States)

    Eberspeaker, Philip; Fairbrother, Debora

    2013-01-01

    The U. S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a total of 30 to 40 missions per year in support of the NASA scientific community and other users. The NASA Sounding Rockets Program supports the science community by integrating their experiments into the sounding rocket payloads, and providing both the rocket vehicle and launch operations services. Activities since 2011 have included two flights from Andoya Rocket Range, more than eight flights from White Sands Missile Range, approximately sixteen flights from Wallops Flight Facility, two flights from Poker Flat Research Range, and four flights from Kwajalein Atoll. Other activities included the final developmental flight of the Terrier-Improved Malemute launch vehicle, a test flight of the Talos-Terrier-Oriole launch vehicle, and a host of smaller activities to improve program support capabilities. Several operational missions have utilized the new Terrier-Malemute vehicle. The NASA Sounding Rockets Program is currently engaged in the development of a new sustainer motor known as the Peregrine. The Peregrine development effort will involve one static firing and three flight tests with a target completion data of August 2014. The NASA Balloon Program supported numerous scientific and developmental missions since its last report. The program conducted flights from the U.S., Sweden, Australia, and Antarctica utilizing standard and experimental vehicles. Of particular note are the successful test flights of the Wallops Arc Second Pointer (WASP), the successful demonstration of a medium-size Super Pressure Balloon (SPB), and most recently, three simultaneous missions aloft over Antarctica. NASA continues its successful incremental design qualification program and will support a science mission aboard WASP in late 2013 and a science mission aboard the SPB in early 2015. NASA has also embarked on an intra-agency collaboration to launch a rocket from a balloon to

  8. Generalised ballooning theory of two-dimensional tokamak modes

    Science.gov (United States)

    Abdoul, P. A.; Dickinson, D.; Roach, C. M.; Wilson, H. R.

    2018-02-01

    In this work, using solutions from a local gyrokinetic flux-tube code combined with higher order ballooning theory, a new analytical approach is developed to reconstruct the global linear mode structure with associated global mode frequency. In addition to the isolated mode (IM), which usually peaks on the outboard mid-plane, the higher order ballooning theory has also captured other types of less unstable global modes: (a) the weakly asymmetric ballooning theory (WABT) predicts a mixed mode (MM) that undergoes a small poloidal shift away from the outboard mid-plane, (b) a relatively more stable general mode (GM) balloons on the top (or bottom) of the tokamak plasma. In this paper, an analytic approach is developed to combine these disconnected analytical limits into a single generalised ballooning theory. This is used to investigate how an IM behaves under the effect of sheared toroidal flow. For small values of flow an IM initially converts into a MM where the results of WABT are recaptured, and eventually, as the flow increases, the mode asymptotically becomes a GM on the top (or bottom) of the plasma. This may be an ingredient in models for understanding why in some experimental scenarios, instead of large edge localised modes (ELMs), small ELMs are observed. Finally, our theory can have other important consequences, especially for calculations involving Reynolds stress driven intrinsic rotation through the radial asymmetry in the global mode structures. Understanding the intrinsic rotation is significant because external torque in a plasma the size of ITER is expected to be relatively low.

  9. Cryo-balloon catheter position planning using AFiT

    Science.gov (United States)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  10. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    Science.gov (United States)

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  11. Training facilitators and supervisors

    DEFF Research Database (Denmark)

    Kjær, Louise Binow; O Connor, Maja; Krogh, Kristian

    At the Master’s program in Medicine at Aarhus University, Denmark, we have developed a faculty development program for facilitators and supervisors in 4 progressing student modules in communication, cooperation, and leadership. 1) A course for module 1 and 3 facilitators inspired by the apprentic...

  12. Trade Facilitation in Ethiopia:

    African Journals Online (AJOL)

    Tilahun_EK

    (UNCTAD), “Trade and transport facilitation … addresses a wide agenda in economic development and trade that may include improving transport infrastructure and services, reducing customs tariffs, and removing non-tariff trade barriers including administrative and regulatory barriers.”24. The definition of trade facilitation ...

  13. Embolization of carotid-cavernous fistula using a silicone balloon and a tracker-catheter system

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Cho, Kil Ho; Park, Bok Hwan

    1992-01-01

    With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in case of small fistula, pseudo aneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitation, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients (silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing

  14. Learning facilitating leadership

    DEFF Research Database (Denmark)

    Rasmussen, Lauge Baungaard; Hansen, Mette Sanne

    2016-01-01

    deployed for this paper is empirical and conceptual. A specific facilitation project carried out by six international engineering students is presented. The importance of combining cognitive, emotional and synergistic skills is highlighted on the basis of this example, the authors’ extensive experience......This paper explains how engineering students at a Danish university acquired the necessary skills to become emergent facilitators of organisational development. The implications of this approach are discussed and related to relevant viewpoints and findings in the literature. The methodology...... in teaching facilitation and the literature. These types of skills are most effectively acquired by combining conceptual lectures, classroom exercises and the facilitation of groups in a real-life context. The paper also reflects certain ‘shadow sides’ related to facilitation observed by the students...

  15. Impact of chronic rhinosinusitis on work productivity through one-year follow-up after balloon dilation of the ethmoid infundibulum.

    Science.gov (United States)

    Stankiewicz, James; Tami, Thomas; Truitt, Theodore; Atkins, James; Winegar, Bradford; Cink, Paul; Schaeffer, B Todd; Raviv, Joseph; Henderson, Diana; Duncavage, James; Hagaman, David

    2011-01-01

    Although multiple clinical trials have demonstrated that balloon dilation of sinus ostia in patients diagnosed with chronic rhinosinusitis (CRS) results in sustained symptomatic improvement, less data are available to measure the effects of sinusitis on worker productivity. The objective of our research was to analyze work and activity impairment before and after transantral, endoscopically-guided balloon dilation of the maxillary sinus ostia and ethmoid infundibulum. Subjects diagnosed with CRS and computed tomography (CT) evidence of disease in the maxillary sinuses alone, or maxillary and anterior ethmoid sinuses, completed the Work Productivity and Activity Impairment (WPAI) questionnaire and the Work Limitation Questionnaire (WLQ) before treatment and at 3, 6, and 12 months postprocedure. A total of 56 subjects were enrolled and 53 completed the 1-year follow-up. The lost productivity composite score computed from the WLQ improved by 73% (9.0 to 2.4; p productivity at work as measured by the WPAI improved by approximately 76% (38.3 to 9.2; p problems impose a substantial burden on work productivity and physical/mental activity levels. Treatment of CRS by dilating the maxillary sinus ostium and ethmoid infundibulum can significantly improve quality of life (QOL) and work productivity. Copyright © 2011 American Rhinologic Society-American Academy of Otolaryngic Allergy, LLC.

  16. Endoscopic versus open bursectomy of lateral malleolar bursitis.

    Science.gov (United States)

    Choi, Jae Hyuck; Lee, Kyung Tai; Lee, Young Koo; Kim, Dong Hyun; Kim, Jeong Ryoul; Chung, Woo Chull; Cha, Seung Do

    2012-06-01

    Compare the result of endoscopic versus open bursectomy in lateral malleolar bursitis. Prospective evaluation of 21 patients (22 ankles) undergoing either open or endoscopic excision of lateral malleolar bursitis. The median age was 64 (38-79) years old. The median postoperative follow-up was 15 (12-18) months. Those patients undergoing endoscopic excision showed a higher satisfaction rate (excellent 9, good 2) than open excision (excellent 4, good 3, fair 1). The wounds also healed earlier in the endoscopic group although the operation time was slightly longer. One patient in the endoscopic group had recurrence of symptoms but complications in the open group included one patient with skin necrosis, one patient with wound dehiscence, and two patients of with superficial peroneal nerve injury. Endoscopic resection of the lateral malleolar bursitis is a promising technique and shows favorable results compared to the open resection. Therapeutic studies-Investigating the result of treatment, Level II.

  17. Advances in the endoscopic management of gastric outflow disorders.

    Science.gov (United States)

    Storm, Andrew C; Ryou, Marvin

    2017-11-01

    Disorders of gastric outflow and outlet obstruction include a variety of benign and malignant disorders such as peptic strictures, foreign bodies, gastroparesis, and cancers of the stomach, duodenum, and pancreas. Historically, a majority of patients presenting with gastric outlet obstruction (GOO) were to the result of peptic ulcers and surgical management of peptic ulcer complications was a mainstay of general surgical training. Invasive surgery is being performed less frequently today due to realization of the role of Helicobacter pylori in peptic ulcer disease and the introduction of novel endoscopic techniques for management of GOO. For malignant GOO, the introduction of lumen-apposing metal stents have opened the door for the development and performance of endoscopic ultrasound-guided gastric bypass procedures. For benign GOO, including gastroparesis and pyloric stenosis, endoscopic myotomy shows promise. Endoscopic ultrasound-guided gastric bypass, per-oral endoscopic myotomy, and other novel techniques in the endoscopic management of GOO, are discussed in this review.

  18. Endoscopic treatment of vesicoureteral reflux in pediatric patients

    Directory of Open Access Journals (Sweden)

    Jong Wook Kim

    2013-04-01

    Full Text Available Endoscopic treatment is a minimally invasive treatment for managing patients with vesicoureteral reflux (VUR. Although several bulking agents have been used for endoscopic treatment, dextranomer/hyaluronic acid is the only bulking agent currently approved by the U.S. Food and Drug Administration for treating VUR. Endoscopic treatment of VUR has gained great popularity owing to several obvious benefits, including short operative time, short hospital stay, minimal invasiveness, high efficacy, low complication rate, and reduced cost. Initially, the success rates of endoscopic treatment have been lower than that of open antireflux surgery. However, because injection techniques have been developed, a recent study showed higher success rates of endoscopic treatment than open surgery in the treatment of patients with intermediate- and high-grade VUR. Despite the controversy surrounding its effectiveness, endoscopic treatment is considered a valuable treatment option and viable alternative to long-term antibiotic prophylaxis.

  19. Current Considerations in Direct Percutaneous Endoscopic Jejunostomy

    Directory of Open Access Journals (Sweden)

    Yanfei Zhu

    2012-01-01

    Full Text Available For patients who are unable to meet their nutritional needs orally, enteral feeding via a percutaneous approach has become the mainstay of therapy. However, traditional enteral feeding methods, such as percutaneous endoscopic gastrostomy, may not be viable options for patients with severe gastroparesis or gastric outlet obstruction. Direct percutaneous endoscopic jejunostomy (DPEJ is an enteral access method that was first described more than 20 years ago and has gained popularity among gastroenterologists. This review discusses the indications for and contraindications to DPEJ, the procedure, the application of DPEJ in specific subsets of patients with gastrointestinal disorders, and presents a brief tabular summary of complications and success rates of DPEJ in case series published since 2000.

  20. Emerging indications of endoscopic radiofrequency ablation

    Science.gov (United States)

    Becq, Aymeric; Camus, Marine; Rahmi, Gabriel; de Parades, Vincent; Marteau, Philippe

    2015-01-01

    Introduction Radiofrequency ablation (RFA) is a well-validated treatment of dysplastic Barrett's esophagus. Other indications of endoscopic RFA are under evaluation. Results Four prospective studies (total 69 patients) have shown that RFA achieved complete remission of early esophageal squamous intra-epithelial neoplasia at a rate of 80%, but with a substantial risk of stricture. In the setting of gastric antral vascular ectasia, two prospective monocenter studies, and a retrospective multicenter study, (total 51 patients), suggest that RFA is efficacious in terms of reducing transfusion dependency. In the setting of chronic hemorrhagic radiation proctopathy, a prospective monocenter study and a retrospective multicenter study (total 56 patients) suggest that RFA is an efficient treatment. A retrospective comparative study (64 patients) suggests that RFA improves stents patency in malignant biliary strictures. Conclusions Endoscopic RFA is an upcoming treatment modality in early esophageal squamous intra-epithelial neoplasia, as well as in gastric, rectal, and biliary diseases. PMID:26279839

  1. Advances in the Endoscopic Management of Obesity

    Directory of Open Access Journals (Sweden)

    Jason Behary

    2015-01-01

    Full Text Available Obesity has become a worldwide epidemic with significant impact on quality of life, morbidity, and mortality rates. Over the past two decades, bariatric surgery has established itself as the most effective and durable treatment for patients with obesity and its associated comorbidities. However, despite the use of minimally invasive techniques, bariatric surgery is associated with complications in approximately 15% of patients, has a substantial cost, and is used by only 1% of patients who are eligible. Therefore, there is a need for effective minimally invasive therapies, which will be utilized by the large proportion of obese patients who are in desperate need of treatment but are not receiving any. Endoscopic approaches to the management of obesity have been developed, with the aim of delivering more effective, durable, and safer methods of weight reduction. In this paper, we review currently available and future endoscopic therapies that will likely join the armamentarium used in the management of obesity.

  2. Comprehensive review on endonasal endoscopic sinus surgery

    Science.gov (United States)

    Weber, Rainer K.; Hosemann, Werner

    2015-01-01

    Endonasal endoscopic sinus surgery is the standard procedure for surgery of most paranasal sinus diseases. Appropriate frame conditions provided, the respective procedures are safe and successful. These prerequisites encompass appropriate technical equipment, anatomical oriented surgical technique, proper patient selection, and individually adapted extent of surgery. The range of endonasal sinus operations has dramatically increased during the last 20 years and reaches from partial uncinectomy to pansinus surgery with extended surgery of the frontal (Draf type III), maxillary (grade 3–4, medial maxillectomy, prelacrimal approach) and sphenoid sinus. In addition there are operations outside and beyond the paranasal sinuses. The development of surgical technique is still constantly evolving. This article gives a comprehensive review on the most recent state of the art in endoscopic sinus surgery according to the literature with the following aspects: principles and fundamentals, surgical techniques, indications, outcome, postoperative care, nasal packing and stents, technical equipment. PMID:26770282

  3. Portal biliopathy treated with endoscopic biliary stenting

    Directory of Open Access Journals (Sweden)

    Sung Jin Jeon

    2016-03-01

    Full Text Available Portal biliopathy is defined as abnormalities in the extra- and intrahepatic ducts and gallbladder of patients with portal hypertension. This condition is associated with extrahepatic venous obstruction and dilatation of the venous plexus of the common bile duct, resulting in mural irregularities and compression of the biliary tree. Most patients with portal biliopathy remain asymptomatic, but approximately 10% of them advance to symptomatic abdominal pain, jaundice, and fever. Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography are currently used as diagnostic tools because they are noninvasive and can be used to assess the regularity, length, and degree of bile duct narrowing. Management of portal biliopathy is aimed at biliary decompression and reducing the portal pressure. Portal biliopathy has rarely been reported in Korea. We present a symptomatic case of portal biliopathy that was complicated by cholangitis and successfully treated with biliary endoscopic procedures.

  4. Fundus imaging with a nasal endoscope

    Directory of Open Access Journals (Sweden)

    P Mahesh Shanmugam

    2015-01-01

    Full Text Available Wide field fundus imaging is needed to diagnose, treat, and follow-up patients with retinal pathology. This is more applicable for pediatric patients as repeated evaluation is a challenge. The presently available imaging machines though provide high definition images, but carry the obvious disadvantages of either being costly or bulky or sometimes both, which limits its usage only to large centers. We hereby report a technique of fundus imaging using a nasal endoscope coupled with viscoelastic. A regular nasal endoscope with viscoelastic coupling was placed on the cornea to image the fundus of infants under general anesthesia. Wide angle fundus images of various fundus pathologies in infants could be obtained easily with readily available instruments and without the much financial investment for the institutes.

  5. Devices and Endoscopic Bariatric Therapies for Obesity.

    Science.gov (United States)

    Saunders, Katherine H; Igel, Leon I; Saumoy, Monica; Sharaiha, Reem Z; Aronne, Louis J

    2018-04-17

    In this review, we describe the FDA-approved and investigational devices and endoscopic bariatric therapies for the treatment of obesity. We focus on literature published in the past few years and present mechanisms of action as well as efficacy and safety data. Devices and endoscopic procedures are emerging options to fill the significant treatment gap in the management of obesity. Not only are these devices and procedures minimally invasive and reversible, but they are potentially more effective than antiobesity medications, often safer for poor surgical candidates and possibly less expensive than bariatric surgery. As many patients require a variety of management strategies (medications, devices, procedures, and/or surgery) in addition to lifestyle modifications to achieve clinically significant weight loss, the future of obesity treatment involves a multidisciplinary approach. Combinations of advanced treatment strategies can lead to additive or synergistic weight loss. This is an area that requires further investigation.

  6. Endoscopic Treatment of Intrasheath Peroneal Tendon Subluxation

    Directory of Open Access Journals (Sweden)

    Frederick Michels

    2013-01-01

    Full Text Available Intrasheath subluxation of the peroneal tendons within the peroneal groove is an uncommon problem. Open exploration combined with a peroneal groove-deepening procedure and retinacular reefing is the recommended treatment. This extensive lateral approach needs incision of the intact superior peroneal retinaculum and repair afterwards. We treated three patients with a painful intrasheath subluxation using an endoscopic approach. During this tendoscopy both tendons were inspected. The distal muscle fibers of the peroneus brevis tendon were resected in two patients. A partial tear was debrided in the third patient. All patients had a good result. No wound-healing problems or other complications occurred. Early return to work and sports was possible. An endoscopic approach was successful in treatment of an intrasheath subluxation of the peroneal tendons.

  7. Recent trends in endoscopic management of achalasia

    OpenAIRE

    Tolone, Salvatore; Limongelli, Paolo; del Genio, Gianmattia; Brusciano, Luigi; Russo, Antonio; Cipriano, Lorenzo; Terribile, Marco; Docimo, Giovanni; Ruggiero, Roberto; Docimo, Ludovico

    2014-01-01

    Esophageal achalasia is a chronic and progressive motility disorder characterized by absence of esophageal body peristalsis associated with an impaired relaxation of lower esophageal sphincter (LES) and usually with an elevated LES pressure, leading to an altered passage of bolus through the esophago-gastric junction. A definitive cure for achalasia is currently unavailable. Palliative treatment options provide only food and liquid bolus intake and relief of symptoms. Endoscopic therapy for a...

  8. Gastric varices: Classification, endoscopic and ultrasonographic management

    Directory of Open Access Journals (Sweden)

    Zeeshan Ahmad Wani

    2015-01-01

    Full Text Available Gastric varices (GV are responsible for 10-30% of all variceal hemorrhage. However, they tend to bleed more severely with higher mortality. Around 35-90% rebleed after spontaneous hemostasis. Approximately 50% of patients with cirrhosis of liver harbor gastroesophageal varices. In this review, new treatment modalities in the form of endoscopic treatment options and interventional radiological procedures have been discussed besides discussion on classification and pathophysiology of GV.

  9. ENDOSCOPIC THERAPY IN EXTRAHEPATIC BILIARY STRICTURES

    OpenAIRE

    Haapamäki, Carola

    2016-01-01

    Extrahepatic biliary strictures are mainly managed using stents when treated endoscopically. At present, the main stent types in clinical practice are non expandable plastic stents (NEPS) and self-expandable metallic stents (SEMS), with an up to tenfold cost for the latter. In current praxis, SEMS are widely used for palliative management of malignant biliary strictures as they have longer patency.The role of SEMS in preoperative stenting and the management of benign biliary strictures (BBS) ...

  10. Endoscopic Treatment of Intrasheath Peroneal Tendon Subluxation

    OpenAIRE

    Michels, Frederick; Jambou, St?phane; Guillo, St?phane; Van Der Bauwhede, Jan

    2012-01-01

    Intrasheath subluxation of the peroneal tendons within the peroneal groove is an uncommon problem. Open exploration combined with a peroneal groove-deepening procedure and retinacular reefing is the recommended treatment. This extensive lateral approach needs incision of the intact superior peroneal retinaculum and repair afterwards. We treated three patients with a painful intrasheath subluxation using an endoscopic approach. During this tendoscopy both tendons were inspected. The distal mus...

  11. Limited Approach in Endoscopic Dacryocystorhinostomy of Pediatrics

    OpenAIRE

    Hashemi, Seyyed Mostafa; Eshaghian, Afrooz

    2017-01-01

    Background: Limited spatial nasal cavity in children, make pediatric dacryocystorhinostomy (DCR) a difficult surgical procedure. We apply a limited approach to pediatric DCR and follow them for their consequences. Materials and Methods: An experimental study was done in pediatric DCR with limited approach (age < 14-year-old). After written consent, with general anesthesia, with nasal endoscopic surgery, lacrimal bone is exposed and extruded. In contrast with routine procedure, ascending proce...

  12. A Primer on Endoscopic Electronic Medical Records

    OpenAIRE

    Atreja, Ashish; Rizk, Maged; Gurland, Brooke

    2010-01-01

    Endoscopic electronic medical record systems (EEMRs) are now increasingly utilized in many endoscopy centers. Modern EEMRs not only support endoscopy report generation, but often include features such as practice management tools, image and video clip management, inventory management, e-faxes to referring physicians, and database support to measure quality and patient outcomes. There are many existing software vendors offering EEMRs, and choosing a software vendor can be time consuming and co...

  13. Endoscopic Instruments and Electrosurgical Unit for Colonoscopic Polypectomy

    OpenAIRE

    Park, Hong Jun

    2016-01-01

    Colorectal polypectomy is an effective method for prevention of colorectal cancer. Many endoscopic instruments have been used for colorectal polypectomy, such as snares, forceps, endoscopic clips, a Coagrasper, retrieval net, injector, and electrosurgery generator unit (ESU). Understanding the characteristics of endoscopic instruments and their proper use according to morphology and size of the colorectal polyp will enable endoscopists to perform effective polypectomy. I reviewed the characte...

  14. [Endoscopic implantation of endoprostheses in incurable esophageal and cardia cancer].

    Science.gov (United States)

    Wiesenhaken, U; Rogos, R

    1990-03-01

    The palliative treatment of tumorous stenosis of the esophagus and cardio-esophageal region by intubation with an endoprosthesis leads to an improved quality of life. The used endoscopic positioning provides better results than the surgical procedure. This method is easy in handling and has only few complications. The endoscopic positioning of endoprosthesis is also a really alternative of alimentary fistula. The positioning of plastic prosthesis under endoscopic control should be given preference in the palliative treatment of obstructing cardio-esophageal malignancy.

  15. Per-oral endoscopic myotomy for achalasia: An American perspective

    OpenAIRE

    Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H; Stavropoulos, Stavros N

    2013-01-01

    Achalasia is an uncommon esophageal motility disorder characterized by the selective loss of enteric neurons leading to absence of peristalsis and impaired relaxation of the lower esophageal sphincter. Per-oral endoscopic myotomy (POEM) is a novel modality for the treatment of achalasia performed by gastroenterologists and surgeons. It represents a natural orifice transluminal endoscopic surgery (NOTES) approach to Heller myotomy. POEM has the minimal invasiveness of an endoscopic procedure t...

  16. Treatment Strategy after Incomplete Endoscopic Resection of Early Gastric Cancer

    OpenAIRE

    Kim, Sang Gyun

    2016-01-01

    Endoscopic resection of early gastric cancer is defined as incomplete when tumor cells are found at the resection margin upon histopathological examination. However, a tumor-positive resection margin does not always indicate residual tumor; it can also be caused by tissue contraction during fixation, by the cautery effect during endoscopic resection, or by incorrect histopathological mapping. Cases of highly suspicious residual tumor require additional endoscopic or surgical resection. For in...

  17. Practical Approach to Endoscopic Management for Bleeding Gastric Varices

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Young Suk [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-02-15

    Bleeding from gastric varices is generally more severe than bleeding from esophageal varices, although it occurs less frequently. Recently, new endoscopic treatment options and interventional radiological procedures have broadened the therapeutic armamentarium for gastric varices. This review provides an overview of the classification and pathophysiology of gastric varices, an introduction to current endoscopic and interventional radiological management options for gastric varices, and details of a practical approach to endoscopic variceal obturation using N-butyl-2-cyanoacrylate.

  18. Treatment of nonseptic bursitis with endoscopic surgery

    Directory of Open Access Journals (Sweden)

    Azad Yıldırım

    2015-09-01

    Full Text Available Objective: The aim of this study was to show that endoscopic surgery is a simple and acceptable method for various problems associated with wounds, range of motion and that such surgery ensures an early return to work after treatment of nonresponding nonseptic bursitis. Methods: Thirty-two patients with nonseptic bursitis caused by repeated minor trauma that did not respond to medical treatment from 2008 to 2012 were included in this study. Radiographic [anteroposterior and lateral], ultrasound, macro and microscopic analyses of drainage liquid and aerobic and anaerobic cultures were obtained from the patients for the diagnosis. Results: The mean age was 40.8 years. Fifteen patients had prepatellar bursitis, 13 had olecranon bursitis and 4 had ankle bursitis. Two patients had a history of falling on their knee. The other patients had a history of repetitive stimulation .The mean follow up period was 2.6 years [range. 2-5 years] and no medical complications occurred after the endoscopic surgery; such as scarring, loss of sensation and infection. One recurrence in response to medical treatment was observed. Conclusion: Endoscopic bursectomy is a short and acceptable procedure with excellent results in terms of returning to work early and minimal wound related problems. J Clin Exp Invest 2015; 6 (3: 220-223

  19. Endoscopic laryngeal web formation for pitch elevation.

    Science.gov (United States)

    Anderson, Jennifer

    2007-02-01

    Endoscopic laryngeal web formation has been used to elevate the speaking voice, primarily in male to female transsexuals as part of gender reassignment intervention. The goal of this article is to review the literature regarding surgical treatment for pitch elevation and to describe a novel method of laryngeal web formation. The results of this technique are also reported in a series of six patients. All patients were assessed and treated at the St. Michael's Hospital Voice Disorders Clinic, a tertiary referral centre for voice disorders. Pre- and postoperative voice recordings, acoustic analysis, and videostroboscopic examinations were performed in this series. The acoustic data collected included isolated vowel samples, a reading task, and a modified voice range profile. The patients all underwent successful endoscopic web formation with a Gelfoam augmentation technique. The voice results collected at least 6 months after vocal fold web formation demonstrate a dramatic increase in the habitual speaking fundamental frequency. This new modification for endoscopic web formation has been shown to be a successful procedure for permanent elevation of pitch with little or no morbidity.

  20. Recent trends in endoscopic management of achalasia.

    Science.gov (United States)

    Tolone, Salvatore; Limongelli, Paolo; Del Genio, Gianmattia; Brusciano, Luigi; Russo, Antonio; Cipriano, Lorenzo; Terribile, Marco; Docimo, Giovanni; Ruggiero, Roberto; Docimo, Ludovico

    2014-09-16

    Esophageal achalasia is a chronic and progressive motility disorder characterized by absence of esophageal body peristalsis associated with an impaired relaxation of lower esophageal sphincter (LES) and usually with an elevated LES pressure, leading to an altered passage of bolus through the esophago-gastric junction. A definitive cure for achalasia is currently unavailable. Palliative treatment options provide only food and liquid bolus intake and relief of symptoms. Endoscopic therapy for achalasia aims to disrupt or weaken the lower esophageal sphincter. Intra-sphincteric injection of botulinum toxin is reserved for elderly or severely ill patients. Pneumatic dilation provides superior results than botulinum toxin injection and a similar medium-term efficacy almost comparable to that attained after surgery. Per oral endoscopic myotomy is a promising option for treating achalasia, but it requires increased experience and further objective and long-term follow up. This article will review different endoscopic treatments in achalasia, and summarize the short-term and long-term outcomes.