  1. Balloon angioplasty for disruption of tunneled dialysis catheter fibrin sheath.

    Science.gov (United States)

    Watorek, Ewa; Golebiowski, Tomasz; Letachowicz, Krzysztof; Garcarek, Jerzy; Kurcz, Jacek; Bartosik, Hanna Augustyniak; Letachowicz, Waldemar; Weyde, Waclaw; Klinger, Marian

    2012-01-01

    Management of failing tunneled hemodialysis catheters, sometimes the only vascular access for hemodialysis, presents a difficult problem. In spite of various techniques having been developed, no consensus has been reached about the preferred technique, associated with the longest catheter patency. We report disruption of the fibrin sheath covering dysfunctional tunneled hemodialysis catheter by means of angioplasty, followed by over guidewire catheter exchange. Following the procedure, the catheter placed in the recovered lumen of the vessel presented correct function. The described procedure allowed maintenance of vascular access in our patient. Additionally, dilatation of the concomitant central vein stenosis opens an option for another attempt for arteriovenous fistula creation.

  2. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with pe

  3. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with

  4. Intraoperative balloon angioplasty using fogarty artertial embolectomy balloon catheter for creation of arteriovenous fistula for hemodialysis: single center experience.

    Science.gov (United States)

    Jin, Moran; Yoon, Young Chul; Wi, Jin Hong; Lee, Yang-Haeng; Han, Il-Yong; Park, Kyung-Taek

    2015-04-01

    The purpose of this study was to evaluate the use of a Fogarty arterial embolectomy catheter (Fogarty catheter) in intraoperative balloon angioplasty of the cephalic vein, in order to determine its effect on the patency of arteriovenous fistulas (AVFs) created for hemodialysis access. A total of 156 patients who underwent creation of an AVF were divided into two groups, based whether a Fogarty catheter was used during AVF creation. Group A (89 patients) comprised the patients who underwent balloon angioplasty with a Fogarty catheter during the operation. Group B (67 patients) included the patients in whom a Fogarty catheter was not used during the operation. Patient records were reviewed retrospectively and documented. The patency rate was determined by the Kaplan-Meier method. The records of 156 patients who underwent the creation of an AVF from January 2007 to October 2011 were included. The mean follow-up duration was 40.2±19.4 months (range, 1 to 97 months). The patency rates in group A at 12, 36, and 72 months were 83.9%±3.9%, 78.3%±4.6%, and 76.3%±4.9%, respectively, while the corresponding patency rates in group B were 92.5%±3.2%, 82.8%±0.5%, and 79.9%±5.7%, respectively. The patency rates in group B were found to be slightly higher than those in group A, but the difference was not statistically significant (p=0.356). Intraoperative balloon angioplasty of the cephalic vein using the Fogarty catheter is a simple and easily reproducible procedure, and it can be helpful in increasing AVF patency in cases of insufficient runoff or a suboptimal cephalic vein.

  5. Cineangiographic findings and balloon catheter angioplasty of pulmonic valvular stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Kyung Mo; Yoon, Yong Soo; Kim, In One; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-08-15

    Transluminal balloon valvuloplasty was performed in the treatment of congenital pulmonic valvular stenosis in 55 children, aged 4 months to 15 years. The right ventricular outflow tract pressure gradient decreased significantly immediately after the procedure from 87.18 {+-} 56mmHg to 29.62 {+-} 26.48mmHg ({rho} < 0.001). Technical success rate was 98% (54/55 patients) and failed case (1 patient) was due to severe fibrous thickening of valve. Complication occurred in one case, that is tricuspid regurgitation (Grade II) due to suspected rupture of chordae tendinae. The degree of pulmonary conus dilatation was closely related with age than the pressure gradient.

  6. Endovascular brachytherapy from Re-188-filled balloon catheter to prevent restenosis following angioplasty; Endovaskulaere Brachytherapie mit einem Re-188-gefuellten Ballonkatheter zur Praevention der Restenose nach Angioplastie

    Energy Technology Data Exchange (ETDEWEB)

    Kotzerke, J. [Ulm Univ. (Germany). Abt. Nuklearmedizin; Kropp, J. [Technische Univ. Dresden (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2001-12-01

    Stent implantation and endovascular brachytherapy are the single effective methods to reduce restenosis after angioplasty. Gamma- and beta-emitter can be applied. The use of a liquid beta-emitter filled balloon catheter allows nuclear medicine to participate in this new concept of therapy due to the unsealed source. From various beta-emitters Re-188-perrhenate seems to be the most attractive one regarding logistic, radiation protection and costs. Feasibility of the method was demonstrated by several groups. Interim analysis of ECRIS-2 demonstrate an effectiveness comparable to the best of other irradiation data. (orig.) [German] Die endovaskulaere Brachytherapie ist neben der Stentimplantation bisher die einzige Methode, mit der die Restenoserate nach Angioplastie (PTCA) deutlich reduziert werden kann. Sowohl Gamma- wie auch Betastrahler sind einsetzbar. Die Anwendung eines fluessigen Betastrahlers in einem Ballonkatheter erlaubt dem Nuklearmediziner, an diesem Therapiekonzept zu partizipieren, da es sich um die Anwendung eines offenen radioaktiven Isotops handelt. Von den diversen moeglichen Betastrahlern erscheint Re-188-Perrhenat am geeignetsten zu sein im Hinblick auf die Logistik, den Strahlenschutz und die Kosten. Die Praktikabilitaet dieser Methode wurde von mehreren Zentren bestaetigt. Eine Zwischenauswertung der ECRIS-2-Studie aus Ulm ergibt Daten, die grossen amerikanischen Studien keineswegs nachstehen. (orig.)

  7. Intraoperative Balloon Angioplasty Using Fogarty Artertial Embolectomy Balloon Catheter for Creation of Arteriovenous Fistula for Hemodialysis: Single Center Experience

    National Research Council Canada - National Science Library

    Moran Jin; Young Chul Yoon; Jin Hong Wi; Yang-Haeng Lee; Il-Yong Han; Kyung-Taek Park

    2015-01-01

    ...) created for hemodialysis access. Methods: A total of 156 patients who underwent creation of an AVF were divided into two groups, based whether a Fogarty catheter was used during AVF creation. Group A (89 patients...

  8. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    1991-01-01

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  9. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  10. Acute embolic occlusion of the right common iliac artery after revision total hip arthroplasty treated with catheter-directed thrombolysis and balloon angioplasty: A case report

    Directory of Open Access Journals (Sweden)

    Hongqi Yang

    2015-07-01

    Full Text Available Methods: A 63-year-old woman with atrial fibrillation presented clinical symptoms and signs of acute ischemia in the right lower extremity on the 17th postoperative day after revision total hip arthroplasty of the left hip for aseptic loosening of femoral component. Aspirin was discontinued 7 days before surgery. Both computed tomography angiography and digital subtraction angiography demonstrated complete occlusion of the right common iliac artery. An emergency catheter-directed thrombolysis with urokinase combined with balloon angioplasty was performed to obtain complete patency of the right common iliac artery. Results: The patient received anticoagulation and antiplatelet therapy postoperatively and was fine at the 2-year follow-up. Conclusions: This case demonstrated that catheter-directed thrombolysis combined with balloon angioplasty could be an efficacious, minimally invasive approach for the treatment of acute embolic occlusion of the common iliac artery. Preoperative anticoagulation for patients undergoing total hip arthroplasty with long-term use of aspirin for atrial fibrillation needs further investigation.

  11. Pseudoperforation during kissing balloon angioplasty.

    Science.gov (United States)

    Panetta, Carmelo J; Fasseas, Panayotis; Raveendran, Ganesh; Garratt, Kirk N

    2004-11-01

    We describe a case of apparent perforation during kissing balloon angioplasty of a bifurcation lesion. There was no evidence of perforation on follow-up angiography or via intravascular ultrasound. Possible etiologies include minimal perforation that immediately sealed postdeflation or forced contrast into the microvascular bed via a proximal side branch.

  12. Unintended Thermal Injuries from Radiofrequency Ablation: Organ Protection with an Angioplasty Balloon Catheter in an Animal Model

    Directory of Open Access Journals (Sweden)

    Martha-Grace Knuttinen

    2014-01-01

    Full Text Available Objectives: The aim of this study was to investigate a novel approach of using a balloon catheter as a protective device to separate liver from the diaphragm or nearby bowel during radiofrequency ablation (RFA of hepatic dome tumors in an animal model. Materials and Methods: All experimental procedures were approved by animal Institutional Review Board. Using a 3 cm RF needle electrode, 70 hepatic ablation zones were created using ultrasound in 7 pigs. 50 lesions were created using balloon interposition between liver and diaphragm; 20 lesions were created using the balloon device interposed posteriorly between liver and bowel. Additional 21 control lesions were performed. Animals were sacrificed immediately; diaphragm and bowel were then visually inspected and sectioned. Diaphragmatic and bowel injury was then classified according to the depth of thickness. Results: Control lesions caused full thickness injury, either to diaphragm or bowel. During ablation of lesions with balloon interposition, there was significantly less diaphragmatic injury, P < 0.001 and less bowel injury, P < 0.01. Conclusion: Using balloon interposition as a protective device has advantages over previous saline infusion or CO 2 insufflation, providing a safe way to expand percutaneous RFA of liver tumors located on the undersurface of the diaphragm. In addition, this method may be used in protection of other organs adjacent to areas being ablated.

  13. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  14. Angioplasty with drug coated balloons for the treatment of infrainguinal peripheral artery disease.

    Science.gov (United States)

    Werner, Martin

    2016-09-01

    Restenosis or re-occlusion after femoropopliteal angioplasty or stent implantation is the main limitation of endovascular treatment strategies for peripheral artery disease. Within the last years, balloon catheters with anti-proliferative drug coating on the balloon surface have shown to be associated with higher patency rates compared to plain balloon angioplasty. Thus, drug-coated balloons were gradually adopted in many interventional centres for the treatment of femoropopliteal obstructions. The current review summarises the existing evidence for drug-coated balloons in the infrainguinal vessels and their indication in special lesion cohorts.

  15. Cutting balloon angioplasty for intrastent restenosis treatment

    Directory of Open Access Journals (Sweden)

    João Orávio de Freitas Jr

    1999-05-01

    Full Text Available We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA, inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cutting balloon angioplasty using low inflation pressures achieved important luminal gains, in these two cases of intrastent restenosis. Further studies are necessary before the effectiveness of this procedure can be precisely defined.

  16. Balloon Angioplasty for Intracranial Atherosclerotic Disease: A Multicenter Study

    Science.gov (United States)

    Karanam, Lakshmi Sudha Prasanna; Sharma, Mukesh; Alurkar, Anand; Baddam, Sridhar Reddy; Pamidimukkala, Vijaya; Polavarapu, Raghavasarma

    2017-01-01

    Aim To evaluate the role and efficacy of the balloon angioplasty in intracranial atherosclerotic disease (ICAD) in patients who presented with acute stroke due to vessel occlusion and in patients with symptomatic disease despite optimum medical management. Methods From 2013 to 2016, a total of 39 patients (24 males and 15 females with a mean age of 64.5 years) underwent balloon angioplasty over a period of 2 years and 8 months in three different institutions in India. Maverick balloon catheter (Boston scientific) is used in all the patients. MRI brain with MR angiogram was done in all the patients prior to intervention. Twenty-three patients who had underlying severe ICAD presented with acute stroke due to vessel occlusion. Sixteen patients presented with symptomatic ICAD with recurrent ischemic attack due to the progressing underlying disease despite optimum medical management. Technical success, peri-procedural events, and clinical outcomes were documented for all the patients. Results Technical success (residual stenosis 90% of the patients. MR angiogram on follow-up of nine months was done in 26 patients, and none of them had restenosis. Conclusion Balloon angioplasty is a safe option and can be effectively used in patients of ICAD with acceptable risks and promising outcomes. PMID:28702117

  17. MRI temperature mapping during thermal balloon angioplasty.

    Science.gov (United States)

    Shmatukha, Andriy V; Bakker, Chris J G

    2006-04-21

    Knowledge on the thermal dose delivered during thermal balloon angioplasty (TBA) is desirable to understand why TBA's outcome varies widely among patients and why it is subject to high restenosis rates. In its conventional implementation, TBA involves injection of a heated medium into a balloon positioned within a stenotic blood vessel. The medium injection causes flow, motion and susceptibility-redistribution artefacts that are devastating to the proton resonance frequency shift (PRFS) technique of MRI temperature mapping. Here, we propose to separate in time medium injection and heating by first inflating a balloon with a medium at an initial temperature, and then by heating the medium up using laser light. The separation is shown to eliminate all the mentioned artefacts and to enable real-time MRI temperature mapping using the PRFS technique. Accurate and reliable temperature maps were acquired in a TBA balloon itself and in the surrounding phantom tissue during heat application.

  18. Management of failed angioplasty with laser balloon angioplasty

    Science.gov (United States)

    Jenkins, Ronald D.; Spears, J. Richard

    1990-07-01

    Laser balloon angioplasty (LBA) is a technique for improving the post angioplasty result by the radial diffusion of continuous wave Neodymium:YAG laser energy to the arterial wall during the final inflation of percutaneous transluminal coronary angioplasty (PTCA). Potential mechanisms of luminal improvement include sealing of dissections, reduction of arterial recoil, desiccation of thrombus, and reduction of thrombogenicity of tissues at the luminal surface. These effects are helpful in the management of failed PTCA as defined by the presence of a greater than 50% stenosis after conventional PTCA. Preliminary data suggest that LBA may be safe and effective for the treatment of abrupt closure, with a majority of patients successfully avoiding emergency coronary artery bypass surgery. Similarly, a cohort in which the residual post-PTCA luminal diameter was less than 50% of reference diameter (n=13) was subsequently treated with LBA and demonstrated uniform success in improving luminal diameter, with a mean increment of 0.9mm. Data on the long-term clinical outcome of this cohort is encouraging.

  19. Radiofrequency balloon angioplasty. Rationale and proof of principle

    Energy Technology Data Exchange (ETDEWEB)

    Becker, G.J.; Lee, B.I.; Waller, B.F.; Barry, K.J.; Kaplan, J.; Connolly, R.; Dreesen, R.G.; Nardella, P.

    1988-11-01

    Post-angioplasty restenosis (PARS) in atherosclerotic lesions of medium and small arteries occurs in about one-third of cases in the first year following percutaneous transluminal angioplasty (PTA) (early PARS). PARS includes acute spasm, dissection with reclosure, elastic recoil, fibrocellular proliferative response, and progressive atheromatous disease. Fibrocellular proliferation (possibly initiated by platelet derived growth factor) is felt to be culpable in many cases of early PARS (months). Pharmacologic regimens, stents, and thermal welding of the intimal-medial cracks of PTA are among the interventions being developed to deal with PARS. Radiofrequency (RF) current as a source of thermal energy may be useful in combination with balloon angioplasty to reduce PARS. Ideally, this combination would (1) weld intimal-medial cracks of PTA; (2) mold plaque and normal vessel to increase lumen diameters without creating intimal-medial cracks; and (3) destroy medial smooth muscle cells and multipotential cells (cellular substrate of PARS). Canine in vivo studies have established the feasibility of RF-mediated vascular tissue welding. Human aortic specimens (N = 28) were manually dissected into intima-media and media-adventitia layers. Bipolar RF energy (650 KHz, total 300 J) and mechanical pressure (1 atm) (experimental group, N = 24) or mechanical pressure alone (control group, N = 4) were applied to the reapposed specimen layers in a special chamber. The chamber was modified with a bipolar electrode designed to reproduce that planned for an RF balloon angioplasty catheter. Welding was demonstrated in normal and atherosclerotic treated specimens (23/24 or 96%) but not controls (0/4).

  20. Novel paclitaxel-coated angioplasty balloon catheter based on cetylpyridinium salicylate: Preparation, characterization and simulated use in an in vitro vessel model

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Svea, E-mail: svea.petersen@uni-rostock.de [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Kaule, Sebastian [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Stein, Florian [Institute for Chemistry, Analytical and Technical Chemistry University of Rostock, Albert-Einstein-Straße 3a, 18059 Rostock (Germany); Minrath, Ingo; Schmitz, Klaus-Peter [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Kragl, Udo [Institute for Chemistry, Analytical and Technical Chemistry University of Rostock, Albert-Einstein-Straße 3a, 18059 Rostock (Germany); Sternberg, Katrin [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany)

    2013-10-15

    Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer. - Highlights: • We provide detailed in vitro data for definition of DCB coating requirements. • An in vitro vessel model for evaluating drug delivery from DCB is presented. • Innovative ionic liquid-based coatings for DCB are developed. • The coating shows low drug loss and efficient drug transfer.

  1. Association between disruption of fibrin sheaths using percutaneous transluminal angioplasty balloons and late onset of central venous stenosis.

    Science.gov (United States)

    Ni, Nina; Mojibian, Hamid; Pollak, Jeffrey; Tal, Michael

    2011-02-01

    To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A χ(2) test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venous stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.

  2. Healing after arterial dilatation with radiofrequency thermal and nonthermal balloon angioplasty systems.

    Science.gov (United States)

    Kaplan, J; Barry, K J; Connolly, R J; Nardella, P C; Hayes, L L; Lee, B I; Waller, B F; Becker, G J; Callow, A D

    1993-01-01

    Thermal balloon angioplasty has been proposed as a means of reducing acute and delayed reclosure of arteries after percutaneous transluminal balloon angioplasty. A radiofrequency (rf) balloon catheter was used to perform thermal balloon angioplasty on canine arteries in vivo. The histologic appearance of rf-treated sites was compared with that of control sites treated by conventional percutaneous transluminal angioplasty. Acutely, rf-treated sites showed a reduced medial cellularity with preservation of internal elastic lamina except at the transitional zone between thermal injury and normal artery, where localized internal elastic lamina disruption was found. Nonthermal sites showed generalized disruption of internal elastic lamina and normal medial cellularity. Both thermal and nonthermal sites displayed a return of intimal cover commencing at 1 to 2 weeks and completed by 4 weeks. Diffuse myointimal hyperplasia appeared by 2 weeks after injury at breaks in the internal elastic lamina along the nonthermal vessels but was localized to the transitional zone in thermal injury sites. In rf-treated vessels, repopulation of the acellular thermally modified media had commenced by 4 weeks, and by 8 weeks the media was diffusely repopulated by spindle-shaped cells resembling smooth muscle cells lying between and aligned with preserved connective tissue laminae. Overall, the distribution and extent of the proliferative response after rf thermal balloon angioplasty were less than those seen after nonthermal balloon angioplasty. Thermal sites, which underwent reintimalization before medial cells returned, were considerably less prone to the development of myointimal hyperplasia. These results suggest that this modality may have beneficial effects on arterial healing after angioplasty.

  3. Residual stenosis after conventional balloon angioplasty for hemodialysis shunt failure: treatment with metallic stent placement and post-balloon dilatation.

    Science.gov (United States)

    Kariya, Shuji; Tanigawa, Noboru; Kojima, Hiroyuki; Komemushi, Atsushi; Shiraishi, Tomokuni; Kawanaka, Toshiaki; Sawada, Satoshi

    2005-02-01

    The usefulness of metallic stent placement and post-balloon dilatation was investigated for patients with residual stenosis after conventional percutaneous transluminal balloon angioplasty (balloon PTA) of dialysis shunt vessels. Among 92 patients who had received balloon PTA for dialysis shunt vessels, seven patients who showed a residual waist on the balloon even under maximum inflation were enrolled in this study. In these patients with residual stenosis after balloon PTA, we inserted a stent in the residual stenosis, and post-balloon dilatation was immediately applied using the same balloon catheter. After balloon PTA, the average percent diameter stenosis declined to 45.5 +/- 7.30%, and the stenosis was further improved to an average of 19.3 +/- 7.09% after the placement of a stent and the additional balloon PTA. The average percent diameter dilatation of the balloon before the placement of a stent was 65.8 +/- 12.7%, while the average dilatation increased to 84.1 +/- 8.96% after the placement of a stent. Dialysis became possible immediately after the procedure in all cases. Metallic stent placement and post-balloon dilatation was effective for patients with residual stenosis after conventional balloon PTA of dialysis shunt vessels.

  4. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients

    DEFF Research Database (Denmark)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik

    2015-01-01

    if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected...... angioplasty balloons are unlikely to be useful for detection of bacteria with current PCR techniques in unselected patients with coronary artery disease, more studies are warranted to determine the extent to which bacteria contribute to atherosclerosis and its clinical manifestations and whether the presence......, and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess...

  5. Development of a balloon volume sensor for pulsating balloon catheters.

    Science.gov (United States)

    Nolan, Timothy D C; Hattler, Brack G; Federspiel, William J

    2004-01-01

    Helium pulsed balloons are integral components of several cardiovascular devices, including intraaortic balloon pumps (IABP) and a novel intravenous respiratory support catheter. Effective use of these devices clinically requires full inflation and deflation of the balloon, and improper operating conditions that lead to balloon under-inflation can potentially reduce respiratory or cardiac support provided to the patient. The goal of the present study was to extend basic spirographic techniques to develop a system to dynamically measure balloon volumes suitable for use in rapidly pulsating balloon catheters. The dynamic balloon volume sensor system (DBVSS) developed here used hot wire anemometry to measure helium flow in the drive line from console to catheter and integrated the flow to determine the volume delivered in each balloon pulsation. An important component of the DBVSS was an algorithm to automatically detect and adjust flow signals and measured balloon volumes in the presence of gas composition changes that arise from helium leaks occurring in these systems. The DBVSS was capable of measuring balloon volumes within 5-10% of actual balloon volumes over a broad range of operating conditions relevant to IABP and the respiratory support catheter. This includes variations in helium concentration from 70-100%, pulsation frequencies from 120-480 beats per minute, and simulated clinical conditions of reduced balloon filling caused by constricted vessels, increased driveline, or catheter resistance.

  6. Primary balloon angioplasty plus balloon angioplasty maturation to upgrade small-caliber veins (<3 mm) for arteriovenous fistulas.

    Science.gov (United States)

    De Marco Garcia, Lorena P; Davila-Santini, Luis R; Feng, Qin; Calderin, Julio; Krishnasastry, Kambhampaty V; Panetta, Thomas F

    2010-07-01

    Small-diameter veins are often a limiting factor for the successful creation of arteriovenous fistulas (AVFs). This study evaluated the use of intraoperative primary balloon angioplasty (PBA) as a technique to upgrade small-diameter veins during AVF creation. Sequential balloon angioplasty maturation (BAM) was evaluated as a technique to salvage failed fistulas, expedite maturation, and improve the patency of AVFs after PBA. Sixty-two PBAs were performed in 55 patients with an intent-to-treat using an all-autologous policy. PBAs of veins were performed just before AVF creation using 2.5- to 4-mm angioplasty balloons (1- to 1.5-mm larger than the nominal vein diameter). PBAs were performed through the spatulated end of the vein for a length of up to 8 cm using hydrophilic guidewires and hand inflations without fluoroscopy. BAM was performed in 53 of the 62 PBAs at 2, 4, and 6 weeks after the PBA. Successful outcome was determined as the functional ability to use the fistula for hemodialysis without surgical revision. Of the 62 PBAs, 53 (85.4%), comprising 47 of the original AVFs and 6 new site AVFs created at other sites, remained patent and subsequently underwent BAM with a resulting functional AVF. Fifteen of the 47 original AVFs: 14 due to occlusion; one AVF with a steal was ligated. Seven of the 14 fistulas that occluded were salvaged using recanalization techniques during sequential BAMs. Two of the seven fistulas that were not salvaged required AVGs (3%), and five patients underwent redo AVFs using alternative veins. These five cases were also performed using PBAs and BAMs technique. One patient with a functioning fistula underwent intentional ligation for steal syndrome and also underwent an alternative site AVF, PBA, and BAM. At 3 months, 53 AVFs were functional and successfully used for dialysis. Overall, a working AVF was obtained at the initial site in 47 of 55 patients (85.4%), and 53 (96.3%) received working AVFs that were functioning for dialysis

  7. Human percutaneous and intraoperative laser thermal angioplasty: initial clinical results as an adjunct to balloon angioplasty.

    Science.gov (United States)

    Sanborn, T A; Greenfield, A J; Guben, J K; Menzoian, J O; LoGerfo, F W

    1987-01-01

    In this study, the safety and efficacy of percutaneous laser thermal angioplasty as an adjunct to balloon angioplasty were investigated in 13 patients with severe peripheral vascular disease. By means of a novel fiberoptic laser delivery system (Laserprobe) in which argon laser energy is converted to heat in a metallic tip at the end of the fiberoptic fiber, improvement in the angiographic luminal diameter was noted in 14 of 15 femoropopliteal vessels (93%) by delivering 8 to 13 watts of continuous argon laser energy as the Laserprobe was advanced through the lesion. Initial clinical success (indicated by relief of symptoms and increase in Doppler index) for the combined laser and balloon angioplasty procedures was obtained in 12 of 15 vessels (80%), with inadequate balloon dilatation being the limiting factor in three patients. No significant complications of vessel perforation, dissection, pain, spasm, or embolization of debris occurred. Of the 12 patients who had procedures with initial angiographic and clinical success, 10 (83%) were asymptomatic in the initial follow-up period of 1 to 9 months (mean 6 months). Thus, laser thermal angioplasty with a Laserprobe is a safe and effective adjunct to peripheral balloon angioplasty. This technique has the potential to increase the initial success rate of angioplasty for lesions that are difficult or impossible to treat by conventional means. By removing most of the obstructing lesion, this technique may also reduce recurrent stenosis.

  8. A breakthrough technique for the removal of a hemodialysis catheter stuck in the central vein: endoluminal balloon dilatation of the stuck catheter.

    Science.gov (United States)

    Hong, Joon Ho

    2011-01-01

    Hemodialysis (HD) catheters can get stuck in the central vein after long-term use and their removal might become difficult especially in patients with fibrosed or occluded central veins. Herein, a breakthrough technique is reported for the easy removal of a stuck HD catheter from the central vein. Attempts were made to remove a tunneled double-lumen HD catheter from the central vein of a 74-year-old woman, only to find that the catheter was stuck. The patient was transferred to the operating room and a skin incision was made in the neck and the subcutaneous portion of the HD catheter was retrieved from the tunnel. Under fluoroscopy, a guide wire was inserted into one lumen of the HD catheter and advanced into the right atrium beyond the catheter tip. A 5 mm × 4 cm balloon angioplasty catheter was then inserted into the HD catheter lumen over the guide wire and advanced into the jugular vein junction of the HD catheter around the thoracic inlet. The balloon was inflated to its maximum dimension and pressure. This endoluminal dilatation of the HD catheter was continued by deflating the balloon and then pushing the angioplasty catheter 4 cm at a time towards the tip of the HD catheter in the right atrium. After a second balloon angioplasty catheter of 6 mm × 4 cm was used to expand the entire segment of the other lumen, the HD catheter was pulled out easily from the central vein without any resistance. The endoluminal balloon dilatation of the HD catheter not only separates the stuck HD catheter from the adherent vein by breaking the adhesions between them, but also expands the vein simultaneously, thus enabling easy removal of the HD catheter.

  9. Cutting balloon angioplasty vs. conventional balloon angioplasty in patients receiving intracoronary brachytherapy for the treatment of in-stent restenosis.

    Science.gov (United States)

    Fasseas, Panayotis; Orford, James L; Lennon, Ryan; O'Neill, Jessica; Denktas, Ali E; Panetta, Carmelo J; Berger, Peter B; Holmes, David R

    2004-10-01

    The objective of this study was to evaluate the safety and efficacy of cutting balloon angioplasty (CBA) for the treatment of in-stent restenosis prior to intracoronary brachytherapy (ICB). Cutting balloon angioplasty may reduce the incidence of uncontrolled dissection requiring adjunctive stenting and may limit "melon seeding" and geographic miss in patients with in-stent restenosis who are subsequently treated with ICB. We performed a retrospective case-control analysis of 134 consecutive patients with in-stent restenosis who were treated with ICB preceded by either CBA or conventional balloon angioplasty. We identified 44 patients who underwent CBA and ICB, and 90 control patients who underwent conventional percutaneous transluminal coronary angioplasty (PTCA) and ICB for the treatment of in-stent restenosis. Adjunctive coronary stenting was performed in 13 patients (29.5%) in the CBA/ICB group and 41 patients (45.6%; P 0.05). Despite sound theoretical reasons why CBA may be better than conventional balloon angioplasty for treatment of in-stent restenosis with ICB, and despite a reduction in the need for adjunctive coronary stenting, we were unable to identify differences in clinical outcome.

  10. Optical coherence tomography layer thickness characterization of a mock artery during angioplasty balloon deployment

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Boulet, Benoît; Lamouche, Guy

    2011-03-01

    Optical coherence tomography (OCT) is used to study the deformation of a mock artery in an angioplasty simulation setup. An OCT probe integrated in a balloon catheter provides intraluminal real-time images during balloon inflation. Swept-source OCT is used for imaging. A 4 mm semi-compliant polyurethane balloon is used for experiments. The balloon is inflated inside a custom-built multi-layer artery phantom. The phantom has three layers to mock artery layers, namely, intima, media and adventitia. Semi-automatic segmentation of phantom layers is performed to provide a detailed assessment of the phantom deformation at various inflation pressures. Characterization of luminal diameter and thickness of different layers of the mock artery is provided for various inflation pressures.

  11. Balloon Angioplasty - The Legacy of Andreas Grüntzig, M.D. (1939-1985

    Directory of Open Access Journals (Sweden)

    Matthias eBarton, MD, FAHA

    2014-12-01

    Full Text Available In 1974, at the Medical Policlinic of the University of Zürich, German-born physician-scientist Andreas Grüntzig (1939-1985 successfully applied a balloon-tipped catheter to re-open a severely stenosed femoral artery, a procedure which he initially called percutaneous transluminal dilatation. Transluminal angioplasty of atherosclerotic vascular disease, for which Grüntzig and Charles T. Dotter (1920-1985 received a nomination for the Nobel Prize in Physiology or Medicine in 1978, became one of the most successful examples of translational medicine in the 20th century. Known today as percutaneous transluminal angioplasty (PTA in peripheral arteries or percutaneous transluminal coronary angioplasty (PTCA or percutaneous coronary intervention (PCI in coronary arteries, balloon angioplasty has become the method of choice to treat patients with acute myocardial infarction or occluded leg arteries. On the occasion of the 40th anniversary of balloon angioplasty, we summarize Grüntzig’s life and career in Germany, Switzerland, and the United States and also review the developments in vascular medicine from the 1890s to the 1980s, including Dotter’s first accidental angioplasty in 1963. The work of pioneers of catheterization, including Pedro L. Fariñas in Cuba, André F. Cournand in France, Werner Forssmann, Werner Porstmann and Eberhard Zeitler in Germany, Sven-Ivar Seldinger in Sweden, and Thomas J. Fogarty, Melvin P. Judkins, Richard K. Myler, Dickinson W. Richards, and F. Mason Sones in the United States, is discussed. We also present quotes and excerpts from a unfinished book manuscript by Grüntzig, statements of his former colleagues and contemporary witnesses, and also include hitherto unpublished historic photographs and links to historic materials and archive recordings. This year, on June 25, 2014, Andreas Grüntzig would have celebrated his 75th birthday. This article is dedicated to his memory.

  12. Fibrin sheath angioplasty: a technique to prevent superior vena cava stenosis secondary to dialysis catheters.

    Science.gov (United States)

    Hacker, Robert I; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F

    2012-09-01

    Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters.

  13. A technical strategy for carotid artery stenting: suboptimal prestent balloon angioplasty without poststenting balloon dilatation.

    Science.gov (United States)

    Jin, Sung-Chul; Kwon, O-Ki; Oh, Chang Wan; Jung, Cheolkyu; Han, Moon Gu; Bae, Hee-Joon; Lee, Sang Hyung; Jung, Young Sub; Han, Moon Hee; Kang, Hyun-Seung

    2010-11-01

    Traditional carotid artery stenting (CAS) consists of predilatation, optional deployment of embolic protection devices, stenting, and poststent angioplasty. Each step carries a risk of thromboembolism. To design a new and simplified procedural protocol, suboptimal balloon angioplasty without routine poststenting balloon dilatation, and to describe the efficacy this protocol in terms of procedural risks and angiographic and clinical outcomes. Over a period of 6 years, 161 carotid artery stenoses in 156 consecutive patients were treated by CAS with embolic protection devices. Among them, 110 lesions in 107 patients (68.3%) were treated by our simplified method (symptomatic, > 50% stenosis; asymptomatic, > 70% stenosis). Overall, 98 lesions (88.3%) had severe stenosis (> 70%). The mean stenosis was reduced from 77% to 10% after CAS. A persistent neurological deficit developed in 2 patients from thromboembolism. Hemodynamic insufficiency developed in 14 lesions during CAS (12.7%). The ipsilateral stroke and mortality rate was 4.5% within 1 month after CAS (asymptomatic, 3.6%; symptomatic, 4.8%). Over a mean of 19 months of follow-up, additive angioplasty was performed in 2 patients as a result of progressive restenosis (≥ 50%). A comparison of the balloon sizes of the prestent angioplasty for group 1 (balloon, ≤ 4 mm) and group 2 (balloon, ≥ 5 mm) showed no difference in restenosis between the groups at 15 months of follow-up after CAS. Our CAS technique with suboptimal prestenting angioplasty without routine use of poststenting dilatation is safe, simple, and efficient with acceptable risks.

  14. A randomized comparison of balloon angioplasty versus rotational atherectomy in complex coronary lesions (COBRA study)

    National Research Council Canada - National Science Library

    Dill, T; Dietz, U; Hamm, C W; Küchler, R; Rupprecht, H J; Haude, M; Cyran, J; Ozbek, C; Kuck, K H; Berger, J; Erbel, R

    2000-01-01

    .... The Comparison of Balloon-Angioplasty versus Rotational Atherectomy study (COBRA) is a multicentre, prospective, randomized trial to compare short- and long-term effects of percutaneous transluminal coronary angioplasty (PTCA...

  15. Prevention of restenosis after coronary balloon angioplasty: rationale and design of the Fluvavastatin Angioplasty Restenosis (FLARE) Trial

    NARCIS (Netherlands)

    J.J.R.M. Bonnier (Hans); G. Jackson (Graham); C.M. Miguel (Carlos); J. Shepherd; M.C. Vrolix (Mathias); P.W.J.C. Serruys (Patrick); D.P. Foley (David)

    1994-01-01

    textabstractPrevention of restenosis after successful percutaneous transluminal coronary balloon angioplasty (PTCA) continues to present the greatest therapeutic challenge in interventional cardiology. Experimental and pathological studies describe restenosis as no more than the biologic healing res

  16. Balloon angioplasty to disrupt fibrin sheaths in tunneled dialysis catheters for the treatment of catheter dysfunctionb%球囊破坏纤维鞘纠正血液透析导管功能不良效果观察

    Institute of Scientific and Technical Information of China (English)

    詹申; 杨涛; 张丽红; 刘丽芳; 王玉柱

    2014-01-01

    目的 探索一种处理纤维鞘的新方法以改善透析患者的血流量.方法 6例无法建立动静脉内瘘并有多次多部位中心静脉导管留置史的维持性血液透析患者,经血管造影(Digital Substraction Angiography (DSA)证实存在导管相关纤维鞘.对纤维鞘行经皮腔内球囊扩张血管成形术(percutaneous transluminal angioplasty,PTA),然后经颈内静脉或股静脉途径置入长期中心静脉导管.结果术后应用导管透析,1例患者第2次透析时血流量为220ml/min,其余患者血流量均在250ml/min以上,随访2~6个月,所有患者均未出现导管功能不良及感染.结论球囊破坏纤维鞘可以改善导管的通畅性及血流量.

  17. Modeling plaque fissuring and dissection during balloon angioplasty intervention.

    Science.gov (United States)

    Gasser, T Christian; Holzapfel, Gerhard A

    2007-05-01

    Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage.

  18. Treatment of benign ureteral stricture by double J stents using high-pressure balloon angioplasty

    Institute of Scientific and Technical Information of China (English)

    YU Hua-liang; YE Lin-yang; LIN Mao-hu; YANG Yu; MIAO Rui; HU Xiao-juan

    2011-01-01

    Background Balloon dilatation angioplasty is a minimally invasive surgery for treating benign ureteral stricture. The aim of this study was to investigate the effect of placing double J (D-J) stents using high-pressure balloon angioplasty in treating benign ureteral stricture.Methods A total of 42 patients (48 cases) with benign ureteral stricture (42 had benign ureteral stricture) were investigated by inserting dual D-J stents using high-pressure balloon angioplasty. The control group contained 50 patients (57 cases) employing the conventional balloon angioplasty with a single D-J stent inserted for comparison.Results The overall effective rate of the treated and control groups was 87.8% (36/41) and 62.7% (32/51), respectively (P <0.05).Conclusion This new approach produces a better curative effect than the conventional balloon angioplasty with a single D-J stent insertion in treating benign ureteral stricture.

  19. Balloon pulmonary angioplasty in chronic thromboembolic pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Irene Lang

    2017-03-01

    Full Text Available Chronic thromboembolic pulmonary hypertension (CTEPH is thought to result from incomplete resolution of pulmonary thromboemboli that undergo organisation into fibrous tissue within pulmonary arterial branches, filling pulmonary arterial lumina with collagenous obstructions. The treatment of choice is pulmonary endarterectomy (PEA in CTEPH centres, which has low post-operative mortality and good long-term survival. For patients ineligible for PEA or who have recurrent or persistent pulmonary hypertension after surgery, medical treatment with riociguat is beneficial. In addition, percutaneous balloon pulmonary angioplasty (BPA is an emerging option, and promises haemodynamic and functional benefits for inoperable patients. In contrast to conventional angioplasty, BPA with undersized balloons over guide wires exclusively breaks intraluminal webs and bands, without dissecting medial vessel layers, and repeat sessions are generally required. Observational studies report that BPA improves haemodynamics, symptoms and functional capacity in patients with CTEPH, but controlled trials with long-term follow-up are needed. Complications include haemoptysis, wire injury, vessel dissection, vessel rupture, reperfusion pulmonary oedema, pulmonary parenchymal bleeding and haemorrhagic pleural effusions. This review summarises the available evidence for BPA, patient selection, recent technical refinements and periprocedural imaging, and discusses the potential future role of BPA in the management of CTEPH.

  20. Clinical Experience with a Hybrid Procedure Using the Adherent Clot Catheter for Salvage of Thrombosed Hemodialysis Access: A Comparison with the Standard Fogarty Balloon Catheter.

    Science.gov (United States)

    Yang, Yu Sung; Han, Kyu Dam; Choi, Eun Hye; Park, Young Sam; Seo, Yeon Ho; Kim, Cheol Seung

    2015-03-01

    This study aimed to compare the efficacy of two different catheters in hybrid surgery for salvage of thrombosed hemodialysis accesses. The hybrid salvage procedure (surgical thrombectomy followed by endovascular angioplasty) of the thrombosed hemodialysis access, was performed using adherent clot (AC) catheter in 140 cases and Fogarty balloon catheter in 68 cases. Procedure-related outcomes such as the clot removal status, clinical success, complications, and primary patency rates were analyzed retrospectively. The proportion of cases with good clot removal scores in the AC catheter and Fogarty balloon catheter groups was 77.9% and 91.2%, respectively (P=0.018). Clinical success was achieved in 90.7% of the cases in the AC catheter group and in 98.5% of the cases in the balloon catheter group (P=0.035). The mean patency rates of the two groups were 50.7% and 63.2% at 3 months, 40.7% and 47.1% at 6 months, and 17.9% and 19.1% at 12 months. The complication rates (12.1% and 5.9%) and primary patency rates between the two catheters were not statistically different (P=0.328). On the analysis of the patency rate on access type of autologous (P=0.169) and prothetic graft (P=0.423), there was no significant difference between the two catheter groups. In terms of clot removal and clinical success, the AC catheter did not demonstrate better outcomes than the Fogarty balloon catheter. However, primary patency was not related to the type of catheter. Adherent clot catheter can be a useful alternative to Fogarty balloon catheter for thrombosed hemodialysis access.

  1. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group.

    OpenAIRE

    Serruys, P.W.; de Jaegere, P; Kiemeneij, F.; Macaya, C; Rutsch, W; Heyndrickx, G.; Emanuelsson, H.; Marco, J.; Legrand, Victor; Materne, P.

    1994-01-01

    BACKGROUND: Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as compared with standard balloon angioplasty. METHODS: A total of 520 patients with stable angina and a single coronary-artery lesion were randomly assigned to either stent implantation (262 patients)...

  2. Development of a novel catheter preventing the outflow of debris and thrombus on percutaneous transluminal angioplasty for hemodialysis access fistulas.

    Science.gov (United States)

    Horita, Yuki; Namura, Masanobu; Matsumura, Masami

    2006-06-01

    If a large amount of debris or thrombus dislodges from a lesion because of dilation of the stenotic or occluded lesion in the hemodialysis access fistula when angioplasty is performed, it may move into the pulmonary artery via the central vein, resulting in pulmonary embolism. A novel sheath has been developed to prevent the outflow of debris or thrombus to the central vein. The catheter consists of a 5 F sheath introducer and a silicone balloon attached at the tip of the sheath. The silicon balloon is inflated via small inflation lumen on the shaft wall of the sheath. In the case of percutaneous transluminal angioplasty (PTA), the silicone balloon is inflated to block the blood flow by a mixture of contrast medium and physiological saline, and then dilate a stenotic or occluded lesion by PTA balloon. Next, the debris and thrombus are aspirated using the flush-lumen of this device. Finally, the silicone balloon is deflated and the dilation of the lesion is confirmed. A case of hemodialysis access fistula graft with massive thrombotic occlusion was presented. This device enabled Fogarty procedure using PTA balloon and the blood flow of the graft was completely improved and a large amount of thrombus was removed. This novel device is useful to prevent the embolic complication of the intervention for hemodialysis access fistula. Copyright 2006 Wiley-Liss., Inc.

  3. Parallel wire balloon angioplasty for undilatable venous stenosis in hemodialysis fistula

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Tae Beom; You, Jin Jong; Cho, Jae Min [Gyeongsang National University Hospital, Jinju (Korea, Republic of)] (and others)

    2007-05-15

    The purpose of this study was to assess the value of the parallel wire balloon angioplasty technique for treating dysfunctional hemdialysis fistula with rigid stenosis, and this type of lesion was resistant to conventional angioplasty. Between March 2002 and August 2003, we included 6 patients (mean age: 59, males: 2, females: 4) who were treated via parallel the wire balloon angioplasty technique and their hemodialysis fistula has stenoses that were resistant to conventional angioplasty. We performed conventional angioplasty in all patients, but we failed to achieve sufficient dilatation. In the cases of highly resistant stenosis, an additional 0.016 inch wire was inserted into the 7 F vascular sheath. During angioplasty, a 0.016 inch guide wire was inserted between the balloon and the stenosis and then it was pushed to and fro until the balloon indentation disappeared. After the procedure, we performed angiography to identify the residual stenosis and the procedure-related complications. The undilatable stenoses in 5 patients were successfully resolved without complications via the parallel wire angioplasty technique. In one patient, indentation of balloon was not resolved, but the residual stenosis was both minimal and hemodynamically insignificant. The parallel wire angioplasty technique seems to be a feasible and cost-effective method for treating a dysfunctional hemodialysis fistula with undilatable and rigid stenosis.

  4. 21 CFR 870.1350 - Catheter balloon repair kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the... effect the repair or replacement. (b) Classification. Class III (premarket approval). (c) Date PMA...

  5. Prediction of Outcome after Femoropopliteal Balloon Angioplasty by Intervascular Ultrasound

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith; Vogt, Katja; Just, S.;

    1997-01-01

    original, intravascular ultrasound, percutaneous transluminal angioplasty, peripheral arteries, plaquemorphology, prediction of outcome......original, intravascular ultrasound, percutaneous transluminal angioplasty, peripheral arteries, plaquemorphology, prediction of outcome...

  6. Application of new balloon catheters in the treatment of congenital heart defects

    Science.gov (United States)

    Fiszer, Roland; Szkutnik, Małgorzata; Smerdziński, Sebastian; Chodór, Beata; Białkowski, Jacek

    2016-01-01

    Introduction Balloon angioplasty (BAP) and aortic or pulmonary balloon valvuloplasty (BAV, BPV) are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland) launched and developed. These catheters have not been clinically evaluated yet. Material and methods We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF), 10 BAV and 27 BAP in coarctations of the aorta (CoA) – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations), 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean), BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin). No such complication occured with Valver II. Conclusions Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses. PMID:27625686

  7. MYOCARDIAL PROTECTION DURING CORONARY ANGIOPLASTY WITH AUTOPERFUSION AND FORCED PERFUSION - AN IN-VITRO COMPARISON

    NARCIS (Netherlands)

    DEMUINCK, ED; VERKERKE, BJ; RAKHORST, G; LIE, KI

    1994-01-01

    During coronary angioplasty, perfusion distal to the inflated angioplasty balloon can be maintained with autoperfusion balloon catheters and coronary perfusion pumps. The blood flow rates through the autoperfusion balloon catheters and the flow rates achieved with a perfusion pump were compared in v

  8. Balloon Angioplasty Versus Surgical Repair of Coarctation of Aorta in Infants

    Directory of Open Access Journals (Sweden)

    Fariba Alaei

    2011-09-01

    Full Text Available Background: Coarctation of the aorta is a discrete stenosis of the proximal thoracic aorta. The common clinical pattern is congestive heart failure in infancy. Treatment methods include balloon angioplasty and surgical repair in this age group. Percutaneous balloon angioplasty is a less invasive method for the repair of discrete coarctation but remains controversial as a primary treatment strategy for a native coarctation. This study aimed to compare the effectiveness and outcome of balloon angioplasty and surgical repair in coarctation infants younger than 1 year old.Methods: This retrospective study evaluated the results of the two methods in 167 patients younger than one year old admitted into a tertiary heart center pediatric ward with the diagnosis of coarctation of the aorta: Balloon angioplasty was done for 55 and surgical repair for 112 infants. Patients with previous interventions were not included in this study. Results: Primary results revealed no significant difference in the effectiveness of the two methods (p value = 0.0601. While the rate of recurrent coarctation was significantly lower in the surgery group [19 (17% vs. 11 (20%, p value = 0.0470], the mortality rate was lower in the balloon angioplasty method [5 (5.5% vs. 13 (11.6%, p value = 0.039]. Our multivariate logistic regression model, however, showed no statistically significant difference (p value = 0.120.Conclusion: Because of the incidence of re-coarctation, balloon angioplasty compared with surgical repair did not confer an improved outcome for our infants’ coarctation.

  9. Cephalic arch stenosis in autogenous brachiocephalic hemodialysis fistulas: results of cutting balloon angioplasty

    DEFF Research Database (Denmark)

    Heerwagen, Søren Thorup; Lönn, Lars; Schroeder, Torben V;

    2010-01-01

    Cephalic arch stenosis is a known cause of hemodialysis access failure in patients with brachiocephalic fistulas (BCFs). Outcomes of endovascular treatment are affected by resistance of the stenosis to balloon dilation, a high vein rupture rate and the development of early restenosis. The purpose...... of this retrospective study was to report outcomes after cutting balloon angioplasty (CBA) of cephalic arch stenosis....

  10. Finite Element Modeling of Balloon Angioplasty by Considering Overstretch of Remnant Non-diseased Tissues in Lesions

    Science.gov (United States)

    Gasser, T. Christian; Holzapfel, Gerhard A.

    2007-06-01

    The paper deals with the modeling of balloon angioplasty by considering the balloon-induced overstretch of remnant non-diseased tissues in atherosclerotic arteries. A stenotic artery is modeled as a heterogenous structure composed of adventitia, media and a model plaque, and residual stresses are considered. The constitutive models are able to capture the anisotropic elastic tissue response in addition to the inelastic phenomena associated with tissue stretches beyond the physiological domain. The inelastic model describes the experimentally-observed changes of the wall during balloon inflation, i.e. non-recoverable deformation, and tissue weakening. The contact of the artery with a balloon catheter is simulated by a point-to-surface strategy. The states of deformations and stresses within the artery before, during and after balloon inflation are computed, compared and discussed. The 3D stress states at physiological loading conditions before and after balloon inflation differ significantly, and even compressive normal stresses may occur in the media after dilation.

  11. Vessel wall temperature estimation for novel short term thermal balloon angioplasty: study of thermal environment.

    Science.gov (United States)

    Kaneko, Kenji; Nakatani, Eriko; Futami, Hikaru; Ogawa, Yoshifumi; Arai, Tsunenori; Fukui, Masaru; Shimamura, Satoshi; Kawabata, Takashi

    2005-01-01

    We have been proposing novel thermal balloon angioplasty, photo-thermo dynamic balloon angioplasty (PT-DBA). PTDBA realized thermal injury and low pressure dilatation that can prevent restenosis in chronic phase. We aim to determine the most efficient heating condition suit to individual symptom with pre-operation thermal simulation. We analyzed the flow dynamics and heat convection inside the balloon, and investigated heat conduction of balloon film to establish the temperature estimation method among vessel wall. Compared with ex vivo temperature measurement experiment, we concluded that the factors need to be considered for the establishment would be the heat conduction of the flow inside PTDB, heat conduction at the balloon film, and contact thermal resistance between the balloon film and vessel wall.

  12. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P.A. van den Heuvel (Paul); J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBalloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as c

  13. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease.

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P. van den Heuvel; J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBACKGROUND. Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical o

  14. Comparison of a nitinol stent versus balloon angioplasty for treatment of a dysfunctional arteriovenous graft

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine/Bucheon St. Mary' s Hospital, Bucheon (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-06-15

    This study aimed to 1) evaluate the outcome of placing a nitinol stent for treating dysfunctional arteriovenous grafts (AVG), and 2) compare the results with those of successful balloon angioplasty. Between February 2008 and October 2011, we retrospectively reviewed the interventional data and medical records of 29 patients (21 men, 8 women; mean age, 67.4 years) who underwent interventional procedures for dysfunctional AVG. Stents were placed only in cases with inadequate angioplasty results. Stent patency was evaluated and compared to cases of successful balloon angioplasty using the Kaplan Meier analysis. Eleven stents and 18 angioplasties were performed successfully at the venous anastomotic site of AVG. The primary patency at 3, 6, 12, and 18 months did not differ significantly for stent placement and angioplasty (52%, 29%, 15%, 15% vs. 71%, 50%, 34%, 34%; mean survival, 164 vs. 253 days, p = 0.283). Secondary patency of the stent also did not differ significantly from angioplasty (80%, 80%, 49%, 49% vs. 76%, 57%, 57%, 36%; mean survival, 405 vs. 385 days, p = 0.553). Nitinol stent placement was effective for treating dysfunctional AVG, but did not improve the primary and secondary patency compared to successful angioplasty.

  15. Cutting balloon angioplasty for undilatable venous stenoses causing dialysis graft failure.

    Science.gov (United States)

    Bittl, John A; Feldman, Robert L

    2003-04-01

    Dialysis fistulas and bridge grafts frequently develop outflow stenoses in the venous limb, leading to graft failure. The venous stenoses are fibrotic and require percutaneous transluminal angioplasty with high-pressure balloons. We have encountered venous stenoses in 3 out of 219 hemodialysis patients with graft failure that were undilatable with 6-8 mm high-pressure balloons inflated to more than 24 atm. In each of these cases, treatment with a 4 mm cutting balloon successfully facilitated subsequent balloon dilation at lower pressures. Copyright 2003 Wiley-Liss, Inc.

  16. Effect of low-grade conductive heating on vascular compliance during in vitro balloon angioplasty.

    Science.gov (United States)

    Mitchel, J F; Fram, D B; Aretz, T A; Gillam, L D; Woronick, C; Waters, D D; McKay, R G

    1994-07-01

    Radiofrequency-powered, thermal balloon angioplasty is a new technique that enhances luminal dilatation with less dissection than conventional angioplasty. The purpose of this study was to assess the effect of radiofrequency heating of balloon fluid on the pressure-volume mechanics of in vitro balloon angioplasty and to determine the histologic basis for thermal-induced compliance changes. In vitro, radiofrequency-powered, thermal balloon angioplasty was performed on 46 paired iliac segments freshly harvested from 23 nonatherosclerotic pigs. Balloon inflations at 60 degrees C were compared to room temperature inflations in paired arterial segments. Intraballoon pressure and volume were recorded during each inflation as volume infusion increased pressure over a 0 to 10 atm range. Pressure-volume compliance curves were plotted for all dilatations. Six segments were stained to assess the histologic abnormalities associated with thermal compliance changes. Radiofrequency heating acutely shifted the pressure-volume curves rightward in 20 of 23 iliac segments compared to nonheated controls. This increase in compliance persisted after heating and exceeded the maximum compliance shift caused by multiple nonheated inflations in a subset of arterial segments. Histologically, heated segments showed increased thinning and compression of the arterial wall, increased medial cell necrosis and altered elastic tissue fibers compared to nonheated specimens. In conclusion, radiofrequency heating of intraballoon fluid to 60 degrees C acutely increases vascular compliance during in vitro balloon angioplasty of nonatherosclerotic iliac arteries. The increased compliance persists after heating and can be greater than the compliance shifts induced by multiple conventional dilatations. Arterial wall thinning and irreversible alteration of elastic tissue fibers probably account for thermal compliance changes.

  17. Cost-effectiveness analysis of orbital atherectomy plus balloon angioplasty vs balloon angioplasty alone in subjects with calcified femoropopliteal lesions

    Directory of Open Access Journals (Sweden)

    Weinstock B

    2014-03-01

    Full Text Available Barry Weinstock,1 Raymond Dattilo,2 Tiffini Diage3 1Orlando Health Heart Institute, Mid-Florida Cardiology Specialists, Orlando, FL, USA; 2Department of Cardiology, St Francis Health Center, Topeka, KS, USA; 3North American Science Association (NAMSA, Sunnyvale, CA, USA Introduction: As cost considerations become increasingly critical when selecting optimal endovascular treatment strategies, a cost-benefit analysis was conducted comparing the Diamondback 360°® Orbital Atherectomy System (OAS (Cardiovascular Systems, Inc., St Paul, MN, USA and balloon angioplasty (BA vs BA alone for treatment of calcified femoropopliteal lesions. Patients and methods: The clinical outcomes from COMPLIANCE 360°, a prospective, multicenter, randomized study comparing OAS+BA vs BA alone for treatment of calcified femoropopliteal lesions, were correlated with cost data and previously published quality of life data. Site of service, hospital charges, and associated medical resource utilization were obtained from Uniform Billing statements for index treatments and associated revascularizations out to 1 year. Hospital costs were estimated using hospital-specific, procedure-specific cost-to-charge ratios. Length of stay and procedural data were collected from participating study sites. Results: Twenty-five subjects with 38 lesions and 25 subjects with 27 lesions were randomized to the OAS+BA and BA-alone groups, respectively. Mean hospital charges (US$51,755 vs US$39,922 and estimated hospital costs (US$15,100 vs US$11,016 were higher for OAS+BA compared with BA alone (not statistically significant. Stent utilization was statistically significantly higher with BA-alone treatment for all subjects (1.1 vs 0.1, P=0.001 and in the subset of subjects with one lesion (1.0 vs 0.1, P<0.00001. There was a significant difference in cost for single-lesion versus multiple-lesion treatment. Using costs and quality-adjusted life years (QALYs for the single-lesion cohort, the 1-year

  18. The use of balloon atrial septostomy to facilitate difficult transseptal access in patients undergoing catheter ablation for atrial fibrillation.

    Science.gov (United States)

    Zadeh, Andrew A; Cannom, David S; Macrum, Bruce L; Ho, Ivan C

    2011-07-01

    With the increasing number of patients undergoing repeat catheter ablation procedures for atrial fibrillation, it is not uncommon to encounter a fibrotic interatrial septum that resists the conventional manual advancement of the transseptal sheath. Forceful advancement of the transseptal apparatus can reduce fine control and potentially lead to a higher rate of perforation. We report a case where adjunctive balloon atrial septostomy was used to facilitate transseptal access in a patient with fibrotic interatrial septum. Using a small-caliber angioplasty balloon and under direct fluoroscopic and transesophageal echocardiogram visualization, balloon septostomy was performed with hand inflation until a "waist" was seen. This technique provides a safe way to control the size of the transseptal access created, and allows the passage of a relatively soft-tipped transseptal sheath across a resistive septum. To our knowledge this is the first published use of balloon atrial septostomy during transseptal puncture for left atrium access in a catheter ablation procedure. Balloon atrial septostomy should be considered as an alternative technique for safe transseptal cannulation in select patients in the electrophysiology laboratory or other interventional procedures requiring left atrial access or delivery of large-caliber catheters or sheaths. © 2010 Wiley Periodicals, Inc.

  19. Complications of flow-directed balloon-tipped catheters.

    Science.gov (United States)

    Smart, F W; Husserl, F E

    1990-01-01

    Acute or short-term complications following the use of flow-directed balloon-tipped catheters are well recognized. Long-term sequelae are rarely reported. We report herein an early complication of pulmonary arterial rupture with infarction followed by the delayed development of a pulmonary arterial aneurysm.

  20. Angiographic risk factors of luminal narrowing after coronary balloon angioplasty using balloon measurements to reflect stretch and elastic recoil at the dilation site. The CARPORT Study Group

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); J. Vos (Jeroen); K.J. Beatt (Kevin); P.M.M. Bossuyt (Patrick); W.R. Rutsch (Wolfgang); P.W.J.C. Serruys (Patrick)

    1992-01-01

    textabstractBecause many ongoing clinical restenosis prevention trials are using quantitative angiography to assess whether a drug is capable of reducing the amount of intimal hyperplasia, quantitative angiographic risk factors for angiographic luminal narrowing after balloon angioplasty were determ

  1. Angiographic risk factors of luminal narrowing after coronary balloon angioplasty using balloon measurements to reflect stretch and elastic recoil at the dilatation site

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); J. Vos (Jeroen); K.J. Beatt (Kevin); P.M.M. Bossuyt (Patrick); W.R. Rutsch (Wolfgang); P.W.J.C. Serruys (Patrick)

    1992-01-01

    textabstractAbstract Because many ongoing clinical restenosis prevention trials are using quantitative angiography to assess whether a drug is capable of reducing the amount of intimal hyperplasia, quantitative angiographic risk factors for angiographic luminal narrowing after balloon angioplasty

  2. Cutting-Balloon Angioplasty Versus Balloon Angioplasty as Treatment for Short Atherosclerotic Lesions in the Superficial Femoral Artery: Randomized Controlled Trial

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl; Falkowski, Aleksander, E-mail: bakhis@hot.pl [Pomeranian Medical University, Department of Interventional Radiology (Poland); Safranow, Krzysztof, E-mail: chrissaf@mp.pl; Rac, Monika, E-mail: carmon@pum.edu.pl [Pomeranian Medical University, Department of Biochemistry and Medical Chemistry (Poland); Zawierucha, Dariusz, E-mail: dariusz13@yahoo.com [Interventional Radiology, Sacred Heart Medical Center, River Bend (United States)

    2013-12-15

    Purpose: To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial. Material and Methods: The study group comprised 60 patients (33 men, 27 women; average age 64 years) with a short ({<=}5 cm) focal SFA de novo atherosclerotic stenosis associated with a history of intermittent claudication or rest pain. The primary end point of this study was the rate of binary restenosis in the treated segment 12 months after the intervention. All patients were evenly randomized to either the PTA or CBA treatment arms. Follow-up angiograms and ankle-brachial index (ABI) measurements were performed after 12 months. The evaluation of the restenosis rates and factors influencing its occurrence were calculated by logistic regression analysis. Results: In the intention-to-treat analysis, restenosis rates after 2-month follow-up were 9 of 30 (30 %) in the PTA group and 4 of 30 (13 %) in the CBA group (p = 0.117). In the actual treatment analysis, after exclusion of patients who required nitinol stent placement for a suboptimal result after angioplasty alone (5 patients in the PTA group and none in the CBA group), restenosis rates were 9 of 25 (36 %) and 4 of 30 (13 %), respectively (p = 0.049). In the intention-to-treat analysis there were also significant differences in ABI values between the PTA and CBA groups at 0.77 {+-} 0.11 versus 0.82 {+-} 0.12, respectively (p = 0.039), at 12 months. Conclusion: Based on the presented results of the trial, CBA seems to be a safer and more effective than PTA for treatment of short atherosclerotic lesions in the superior femoral artery.

  3. Usefulness of repeat coronary angiography 24 hours after balloon angioplasty to evaluate early lminal deterioration and facilitate quantitative analysis

    NARCIS (Netherlands)

    G.R. Heyndrickx (Guy); G-J. Laarman (GertJan); H. Suryapranata (Harry); F. Zijlstra (Felix); P.W.J.C. Serruys (Patrick); D.P. Foley (David); A.A. van den Bos (Arjan); J.W. Deckers (Jaap)

    1993-01-01

    textabstractBecause of the unavoidable occurrence of vessel disruption after successful coronary balloon angioplasty, the reliability of quantitative angiographic analysis in that setting has been questioned. For this reason and the suggested occurrence of delayed elastic recoil, repeat angiography

  4. Cutting balloon angioplasty for resistant venous stenoses of dialysis access: immediate and patency results.

    Science.gov (United States)

    Wu, Chih-Cheng; Wen, Szu-Chi

    2008-02-01

    To evaluate the technical success, safety and patency of cutting balloon angioplasty for the treatment of resistant dialysis access stenoses. Cutting balloon angioplasty has been proposed to be useful in treating resistant dialysis access stenoses. However, they are based on experience with very limited cases and formal patency data is insufficient. The author retrospectively reviewed 896 percutaneous transluminal angioplasty (PTA) procedures for the treatment of dysfunctional or thrombotic dialysis access. Thirty-seven of 623 patients with native fistulas and 23 of 273 patients with synthetic grafts had residual stenoses of more than 30% after conventional PTA at an inflation pressure of 24 atm for 60 sec. In these 60 patients, additional cutting balloon PTA was performed. The overall technical success rate was 96.7% and clinical success rate was 98.3%. Only one patient experienced mild local extravasation. The postintervention primary patency rates for native fistula group (N = 37) were 100%, 86.4%, and 67.5% at 1-month, 3-month, and 6-month; the postintervention primary patency rates for synthetic graft group (N = 23) were 87.0%, 60.9%, and 34.2% at 1-month, 3-month, and 6-month respectively. For resistant venous stenoses of dialysis access, cutting balloon PTA is effective, safe, and seems to provide comparative primary patency as suggested by guidelines. Copyright 2008 Wiley-Liss, Inc.

  5. Monitoring of gadolinium-BOPTA uptake into the vessel wall during magnetic resonance (MR)-guided angioplasty of the peripheral arteries with a paclitaxel/gadolinium-BOPTA-coated balloon. An experimental study at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Neizel, M.; Kelm, M. [University Hospital Duesseldorf (Germany). Dept. of Cardiology, Pneumology and Angiology; Ruebben, A.; Weiss, N. [Aachen Resonance, Aachen (Germany); Guenther, R.W. [University Hospital Aachen (Germany). Dept. of Radiology; Krombach, G.A. [University Hospital Giessen (Germany). Dept. of Radiology

    2014-04-15

    Purpose: The success of paclitaxel distribution within the vessel wall during paclitaxel-coated balloon angioplasty to prevent restenosis cannot be monitored under X-ray guidance. The aim of this pilot study was to demonstrate the feasibility of monitoring Gadolinium-BOPTA delivery within the vessel wall during magnetic resonance (MR)-guided paclitaxel/Gadolinium-BOPTA-coated balloon angioplasty of the peripheral arteries. Materials and methods: 6 pigs (47 ± 2 kg) were investigated. All experiments were performed using a 3 Tesla MR scanner. MR-guided bilaterial angioplasty of the iliac arteries was performed using a paclitaxel/MR contrast agent-coated balloon catheter. The feasibility of monitoring the delivery of Gadolinium-BOPTA to the vessel was assessed in 4 animals. In two additional animals, bilateral stenosis was surgically induced in the iliac arteries. Delivery of paclitaxel to the vessel wall was monitored using a 3 D T1-weighted gradient echo (GE) sequence for delineation of the vessel wall. Normalized signal intensity (SI) of the vessel wall was measured before and repeatedly after the intervention for 45 min. in all animals. Results: Paclitaxel/gadolinium-BOPTA-coated balloon angioplasty was successfully accomplished in all iliac arteries (n = 12). In animals with stenosis MR-angiography demonstrated successful dilatation (n = 4). The normalized SI of the vessel wall on T1-weighted GE images significantly increased after the intervention in all animals with and without stenosis for more than 45 min. (p < 0.001). Conclusion: Monitoring of Gadolinium-BOPTA into the vessel wall during MR-guided coated balloon angioplasty is feasible. This is a first step towards providing a tool for the online control of homogenous drug delivery after paclitaxel-coated balloon angioplasty. (orig.)

  6. Ureteric angioplasty balloon placement to increase localised dosage of BCG for renal pelvis TCC.

    LENUS (Irish Health Repository)

    Forde, J C

    2012-03-01

    Endoscopic percutaneous resection of a renal pelvis transitional cell carcinoma (TCC) is a viable treatment option in those who would be rendered dialysis dependent following a nephroureterectomy. We report endoscopic percutaneous resection of an upper tract TCC recurrence in a single functioning kidney followed by antegrade renal pelvis BCG instillation with novel placement of inflated angioplasty balloon in the ureter to help localise its effect.

  7. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate?

  8. T-shaped angioplasty with apex puncture of thrombosed looped hemodialysis grafts.

    Science.gov (United States)

    Oh, Jung Suk; Choi, Byung Gil; Chun, Ho Jong; Lee, Hae Giu

    2013-03-01

    This study is a retrospective evaluation of an alternative technique for angioplasty of thrombosed loop hemodialysis grafts through a single vascular access. This technique can provide balloon angioplasty to the puncture site without any additional vascular accesses by using a T-shaped balloon catheter and can simplify thrombectomy procedures. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  9. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  10. Infrapopliteal Percutaneous Transluminal Balloon Angioplasty: Clinical Results and Influence Factors

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jang Hyeon; Lee, Seung Jin; Jung, Hye Doo; Lim, Jae Hoon; Chang, Nam Kyu; Yim, Nam Yeol; Kim, Jae Kyu [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Lee, Keun Bae [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2011-09-15

    To assess the efficacy of percutaneous transluminal angioplasty (PTA) in patients with infrapopliteal arterial disease, and to determine the influencing factor for prognosis. A total of 55 patients (60 limbs) with infrapopliteal arterial stenosis or occlusion underwent PTA. Atherosclerotic risk factors, clinical symptoms, TransAtlantic Inter-Society Consensus (TASC) classification, and vascular wall calcification were evaluated before PTA. The number of patent infrapopliteal arteries was estimated, and the outcome was evaluated by symptom relief and limb salvage. Technical success was achieved in 53/60 limbs (88.3%) and 81/93 arteries (87.1%), TASC classification (p = 0.038) and vascular calcification (p = 0.002) influenced on technical failure. During follow-up, 26 of 55 limbs (47%) achieved symptom relief and 42/55 limbs (76%) underwent limb salvage. Non-diabetic patients (9/12, 75%) were superior to diabetic patients (17/43, 40%) in terms of symptom relief (p = 0.024). TASC classification and vascular wall calcification influenced on symptom relief and limb salvage. The number of patent infrapopliteal arteries after PTA influenced symptom relief (p < 0.001) and limb amputation (p = 0.003). PTA in patients with chronic critical limb ischemia is worthwhile as a primary treatment. The influence factors should be considered before PTA, and PTA should be performed in as many involved arteries as possible.

  11. Detection of platelet deposition at the site of peripheral balloon angioplasty using indium-111 platelet scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Pope, C.F.; Ezekowitz, M.D.; Smith, E.O.; Rapoport, S.; Glickman, M.; Sostman, H.D.; Zaret, B.L.

    1985-02-01

    Restenosis after balloon angioplasty may be mediated through platelet deposition at the site of arterial dilatation. The purpose of this study was to determine whether platelet deposition at the site of dilatation could be detected using indium-111 platelet scintigraphy. Fifteen patients, aged 60 +/- 9 years, with iliac or femoral (n . 12), renal artery (n . 2) or distal aortic (n . 1) stenoses were studied. All patients received intravenous heparin at the time of dilatation. Labeled platelets containing 471 +/- 65 muCi indium-111 were injected 0.25 to 4 hours after dilatation and 1 to 24 hours after imaging. In 11 of 12 patients with iliac and femoral dilatations, focal uptake was demonstrated at the angioplasty site. In 4 patients (2 patients with renal, 1 patient with iliofemoral, and 1 with distal aortic stenoses), uptake at the dilatation sites was not detected. This preliminary study indicates that despite intravenous heparin, platelets accumulate at sites of balloon dilatation. Platelet scintigraphy may be useful in predicting sites of future narrowing after angioplasty and may be used to test the efficacy of antiplatelet therapy in retarding restenosis.

  12. The laser driven short-term heating balloon catheter: Relation between the chronic neointimal hyperplasia formation and thermal damage to arterial smooth muscle cells.

    Science.gov (United States)

    Shimazaki, Natsumi; Hayashi, Tomoaki; Kunio, Mie; Igami, Yuka; Arai, Tsunenori; Sakurada, Masami

    2010-01-01

    We proposed a novel laser-driven short-term heating angioplasty to realize restenosis-suppressive angioplasty for peripheral artery disease. In this study, we investigated the chronic intimal hyperplasia formation after the short-term heating dilatation in vivo, as well as the thermal damage calculation on arterial smooth muscle cells (SMCs). The prototype short-term heating balloon catheter with 5.0, 5.5, 6.0 mm φ in balloon diameter and 25 mm in balloon length were employed. The short-term heating dilatation was performed in porcine iliac arteries with dilatation conditions of 75°C (N=4) and 65°C (N=5) as peak balloon temperature, 18 ± 4s as heating duration, 3.5 atm as balloon dilatation pressure. Four weeks after the balloon dilatation, the balloon-dilated artery segments were extracted and were stained with HE and picrosirius red for histological observation. In the case of 75°C as the peak balloon temperature, neointimal hyperplasia formation was significantly reduced. In this case, the SMCs density in the artery media measured from the HE-stained specimen was 20% lower than that in the reference artery. According to the thermal damage calculation, it was estimated that the SMCs lethality in artery media after the short-term heating angioplasty was 20% in the case of 75°C as the peak balloon temperature. We demonstrated that the short-term heating dilatation reduced the number of SMCs in artery media. We think this SMCs reduction might contribute to the suppression of chronic neointimal hyperplasia.

  13. Angioplasty and stent placement - heart

    Science.gov (United States)

    ... angioplasty; Coronary artery angioplasty; Percutaneous transluminal coronary angioplasty; Heart artery dilatation ... to carefully guide the catheter up into your heart and arteries. Dye will be injected into your ...

  14. Balloon pulmonary angioplasty: a treatment option for inoperable patients with chronic thromboembolic pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Aiko eOgawa

    2015-02-01

    Full Text Available In chronic thromboembolic pulmonary hypertension, stenoses or obstructions of the pulmonary arteries due to organized thrombi can cause an elevation in pulmonary artery resistance, which in turn can result in pulmonary hypertension. Chronic thromboembolic pulmonary hypertension can be cured surgically by pulmonary endarterectomy; however, patients deemed unsuitable for pulmonary endarterectomy due to lesion, advanced age, or comorbidities have a poor prognosis and limited treatment options. Recently, advances have been made in balloon pulmonary angioplasty for these patients, and this review highlights this recent progress.

  15. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D. [University of Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Zeller, Thomas [Heart Center, Bad Krotzingen (Germany); Coerper, Stephan; Beckert, Stefan [University of Tuebingen, Department of Surgery, Tuebingen (Germany); Balletshofer, Bernd [University of Tuebingen, Department of Angiology, Tuebingen (Germany)

    2007-08-15

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 {+-} 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  16. [Recanalization of the peripheral arteries by laser thermal balloon angioplasty. 2 years of clinical experience].

    Science.gov (United States)

    Riambau Alonso, V; Masotti Centol, M; Latorre Vilallonga, J; Viver Manresa, E; Crexells Figueres, C; Oriol Palou, A

    1991-01-01

    Laser angioplasty represents an attractive alternative to overcome the limitations of balloon angioplasty. We describe our results with laser thermal balloon angioplasty (LTBA) in the treatment of atherosclerosis obliterans in the lower limbs after two years clinical follow up. We also analyse the influence of lesion characteristics on immediate results. Thirty seven patients (34 men), whose mean age was 58 +/- 9 years, were included in this study. Occlusive arterial disease (Fontaine stage II-IV), with 39 significant haemodynamic arterial lesions were present in all of them. Ankle/brachial Doppler index was O,51 +/- 0,17. Eighteen lesions were located in the iliac area (13 stenoses 2,3 +/- 1 cm of length and 5 occlusions 4,2 +/- 3 cm) and 21 lesions in femoro-popliteal area (5 stenoses 2,6 +/- 2 cm and 16 occlusions 5,7 +/- 3 cm). A percutaneous procedure was used in 38 cases and only in one case a femoral dissection was necessary. The laser source was argon in 26 cases and Nd-YAG in 13. The overall immediate angiographic and clinical success was 85% (89% in iliac lesions and 81% in femoropopliteal lesions; 100% in stenoses and 70% in occlusions). The presence of occlusion (p less than 0,01) and/or calcium (p less than O,05) influenced negatively the immediate results. No major complications were observed. Seven (17%) minor complications occurred, but no emergency surgery was necessary. The ankle/brachial Doppler index after treatment was 0,82 +/- 0,21. Cumulative clinical patency was 91% for successfully treated patients after two years follow up. We conclude that LTBA represents an effective and less aggressive way to treat atherosclerosis obliterans.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Plasma levels following application of paclitaxel-coated balloon catheters in patients with stenotic or occluded femoropopliteal arteries

    Energy Technology Data Exchange (ETDEWEB)

    Freyhardt, Patrick; Kroencke, T.J.; Schreiter, N.F.; Sixt, S.; Rastan, A. [Charite Universitaetsmedizin, Berlin (Germany). Klinik fuer Strahlenheilkunde; Zeller, T.; Schwarzwaelder, U. [Herzzentrum Bad Krozingen (Germany). Abt. fuer Klinische und Interventionelle Angiologie; Stiepani, H.; Werk, M. [Martin-Luther-Krankenhaus, Berlin (Germany). Klinik fuer Radiologie und Nuklearmedizin

    2011-05-15

    Purpose: Paclitaxel-coated balloon catheters inhibit restenosis after coronary and peripheral angioplasty (PCI,PTA). The aim of this study was to investigate paclitaxel plasma levels and laboratory parameters following PTA with paclitaxel-coated balloons (PCB) in peripheral arteries. Materials and Methods: This single treatment arm, multicenter study included 14 patients with Rutherford stage 1 - 5 with occlusions of up to 5 cm or {>=} 70 % diameter stenosis of the superficial femoral or popliteal arteries (SFA, PA). PTA was performed using up to three PCB catheters. The paclitaxel plasma levels and safety laboratory parameters were determined by collecting blood samples pre-intervention, immediately post-intervention, at 0.5, 1, 2, 4, 8, 24 hours and 1 and 4 weeks post-intervention (p. i.). Vital signs were monitored to assess clinical safety. Results: PTA was performed successfully in all patients. Paclitaxel plasma levels were always below a level and duration known to cause systemic side effects. A mean peak paclitaxel plasma level (40 ng/ml) was reached immediately p. i. and decreased rapidly below detectable levels in more than half of the patients already 2 hours p. i. The paclitaxel plasma concentrations returned to values below detectable levels at 24 hours p. i. in all patients. Laboratory parameters and vital signs did not give any reason for safety concerns. No adverse events associated with balloon coating were observed. Conclusion: The results of 14 patients with peripheral arterial occlusive disease show no systemic bioavailability of paclitaxel > 24 hours after PTA with one or more PCB catheters, indicating that the PCB catheter is safe with regard to possible systemic effects. (orig.)

  18. Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach.

    Directory of Open Access Journals (Sweden)

    Johannes Salamon

    Full Text Available In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI / magnetic resonance imaging (MRI road map approach and an MPI-guided approach using a blood pool tracer.A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4 was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography.Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide.4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions.

  19. Cost-effectiveness of paclitaxel-coated balloon angioplasty in patients with drug-eluting stent restenosis.

    Science.gov (United States)

    Dorenkamp, Marc; Boldt, Julia; Leber, Alexander W; Sohns, Christian; Roser, Mattias; Boldt, Leif-Hendrik; Haverkamp, Wilhelm; Bonaventura, Klaus

    2013-07-01

    The economic impact of drug-eluting stent (DES) in-stent restenosis (ISR) is substantial, highlighting the need for cost-effective treatment strategies. Compared to plain old balloon angioplasty (POBA) or repeat DES implantation, drug-coated balloon (DCB) angioplasty is a cost-effective therapy for DES-ISR. A Markov state-transition model was used to compare DCB angioplasty with POBA and repeat DES implantation. Model input parameters were obtained from the literature, and the cost analysis was conducted from a German healthcare payer's perspective. Extensive sensitivity analyses were performed. Initial procedure costs amounted to €3488 for DCB angioplasty and to €2782 for POBA. Over a 6-month time horizon, the DCB strategy was less costly (€4028 vs €4169) and more effective in terms of life-years (LYs) gained (0.497 versus 0.489) than POBA. The DES strategy incurred initial costs of €3167 and resulted in 0.494 LYs gained, at total costs of €4101 after a 6-month follow-up. Thus, DCB angioplasty was the least costly and most effective strategy. Base-case results were influenced mostly by initial procedure costs, target lesion revascularization rates, and the costs of dual antiplatelet therapy. DCB angioplasty is a cost-effective treatment option for coronary DES-ISR. The higher initial costs of the DCB strategy compared to POBA or repeat DES implantation are offset by later cost savings. © 2013 Wiley Periodicals, Inc.

  20. Double Balloon Cervical Ripening Catheter for Control of Massive Hemorrhage in a Cervical Ectopic Pregnancy

    Science.gov (United States)

    Zambrano, Nabila; Reilly, James; Moretti, Michael

    2017-01-01

    Cervical pregnancy can be complicated by perfuse vaginal bleeding. Mechanical compression directed at tamponing the cervical vessels can control hemostasis. There are several types of balloon catheters that have been described for cervical compression. However use of a double balloon catheter is a novel approach for cervical tamponade, as one balloon is positioned below the external cervical os and the second balloon is situated above in the internal cervical os. This compresses the cervix from internal os to external os between the two balloons, forming a “cervical sandwich.” We describe this method of cervical tamponade using a silicone double balloon cervical ripening catheter that rapidly controlled hemorrhage in a patient that failed conservative management with methotrexate. PMID:28261511

  1. Probe exchange catheter used for angioplasty of total coronary artery occlusions.

    Science.gov (United States)

    Kiemeneij, F; Suwarganda, J S; van der Wieken, L R

    1990-04-01

    Percutaneous transluminal coronary angioplasty (PTCA) for total occlusions frequently fails, because the guidewire fails to pass the occlusion. With the use of the Probe exchange catheter (PEC), however, stiffness of the guidewire is increased and a higher pushability is obtained in order to manipulate the guidewire beyond the lesion. Once the guidewire has passed, the PEC is advanced and a non-over-the-wire dilatation catheter can be introduced through the PEC. This paper describes the technique in a representative case. The results of this technique in 19 consecutive patients with class III-IV/IV(NYHA) angina due to an occluded coronary artery are presented. In 16 patients the PEC reached the lesion (84%) and in all these patients the guidewire could pass the occlusion. A successful PTCA was performed in 14 patients (74%).

  2. The Renaissance of Transcervical Balloon Catheters for Cervical Ripening and Labour Induction.

    Science.gov (United States)

    Rath, W; Kehl, S

    2015-11-01

    Due to rising rates of labour induction in industrialised countries, safe and effective methods of induction have once again become a focus of interest and research. Prostaglandins are effective for cervical ripening and induction of uterine contractions. They do, however, cause overstimulation of the uterus in up to 20 % of cases, sometimes causing changes in fetal heart rate. Transcervical balloon catheters provide an alternative to prostaglandins for labour induction and have been used for this purpose for almost 50 years. This induction method has experienced a recent renaissance in clinical practice that is reflected in an annually rising number of publications on its use. Balloon catheters allow gentle ripening of the cervix without causing uterine overstimulation. The two catheters available are the Foley catheter (off-label use) and the double balloon catheter, which is licensed for use in induction of labour. Both are as effective as prostaglandins, and do not increase the risk of infection to mother or child. Catheter induction also requires less monitoring compared to prostaglandins resulting in improved patient satisfaction. Balloon catheters provide a useful and promising option to achieve vaginal delivery despite failed prostaglandin induction. Intravenous oxytocin is nevertheless required in up to 85 % of cases for adequate induction/augmentation of contractions. Balloon catheters, vaginal PGE2 and misoprostol are equally effective in the context of an unripe/unfavourable cervix, the rate of uterine hyperstimulation being significantly lower, and the need for oxytocin significantly higher for catheters. Balloon catheters are increasingly being used in combination or sequentially with oral/vaginal misoprostol, although there is currently inadequate published data on the subject. International guidelines recommend the use of balloon catheters for labour induction with an unripe cervix (also following previous caesarean section) as an alternative to

  3. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  4. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  5. Drug-eluting balloon catheters for lower limb peripheral arterial disease: the evidence to date

    Directory of Open Access Journals (Sweden)

    Barkat M

    2016-05-01

    Full Text Available Mohamed Barkat,1 Francesco Torella,1 George A Antoniou2 1Liverpool Vascular and Endovascular Service, Royal Liverpool University Hospital, Liverpool, 2Department of Vascular and Endovascular Surgery, The Royal Oldham Hospital, Pennine Acute Hospitals NHS Trust, Manchester, UK Abstract: A significant proportion of patients with severe lower limb peripheral arterial disease require revascularization. Over the past decade, an endovascular-first approach even for complex disease has gained widespread use among vascular specialists. An important limitation of percutaneous transluminal balloon angioplasty or stenting remains the occurrence of restenosis. Drug-coated balloons have emerged as an exciting technology developed to overcome the limitations of standard balloon angioplasty and stenting. Drug-eluting devices inhibit neointimal growth of vascular smooth muscle cells with the potential of preventing restenosis. This review provides a synopsis of the up-to-date evidence on the role of drug-coated balloons in the treatment of lower limb peripheral arterial disease. Bibliographic searches were conducted using MEDLINE, EMBASE, and the Cochrane Library electronic database. Eleven randomized clinical trials, two systematic reviews, and a published registry providing the best available evidence were identified. Current evidence suggests that angioplasty with drug-coated balloon is reliable, safe, and efficient in increasing patency rates and reducing target lesion revascularization and restenosis. However, it remains unknown whether these improved results can translate into beneficial clinical outcomes, as current randomized clinical trials have failed to demonstrate a significant benefit in limb salvage and mortality. Further randomized trials focusing on clinical and functional outcomes of drug-eluting balloons and on cost versus clinical benefit are required. Keywords: drug-eluting balloon, drug-coated balloon, angioplasty, peripheral arterial

  6. A randomized comparison of balloon angioplasty versus rotational atherectomy in complex coronary lesions (COBRA study).

    Science.gov (United States)

    Dill, T; Dietz, U; Hamm, C W; Küchler, R; Rupprecht, H J; Haude, M; Cyran, J; Ozbek, C; Kuck, K H; Berger, J; Erbel, R

    2000-11-01

    Rotablation is a widely used technique for the treatment of complex coronary artery lesions but is so far only poorly supported by controlled studies. The Comparison of Balloon-Angioplasty versus Rotational Atherectomy study (COBRA) is a multicentre, prospective, randomized trial to compare short- and long-term effects of percutaneous transluminal coronary angioplasty (PTCA) and rotablation in patients with angiographically pre-defined complex coronary artery lesions. At seven clinical sites 502 patients with pre-defined complex coronary artery lesions were assigned to either PTCA (n=250) or rotablation (n=252). Primary end-points were procedural success, 6-month restenosis rates in the treated segments, and major cardiac events during follow-up. Procedural success was achieved in 78% (PTCA), and 85% (rotablation) (P=0.038) of cases. Crossover from PTCA to rotablation was 4% and 10% vice versa (P=0.019). There was no difference between PTCA and rotablation with respect to procedure-related complications such as Q wave infarctions (2.4% each), emergency bypass surgery (1.2% versus 2.4%), and death (1.6% versus 0.4%). However, more stents were required after PTCA (14.9% versus 6.4%, P<0.002), predominantly for bailout or unsatisfactory results. Including bail-out stents as an end-point, the procedural success rates were 73% for angioplasty and 84% for rotablation (P=0.006). At 6 months, symptomatic outcome, target vessel reinterventions and restenosis rates (PTCA 51% versus rotablation 49%, P=0.33) were not different. Complex coronary artery lesions can be treated with a high level of success and low complication rates either by PTCA with adjunctive stenting or rotablation. The long-term clinical and angiographic outcome is comparable.

  7. Critical appraisal of paclitaxel balloon angioplasty for femoral–popliteal arterial disease

    Directory of Open Access Journals (Sweden)

    Herten M

    2016-08-01

    Full Text Available Monika Herten,1 Giovanni B Torsello,1,2 Eva Schönefeld,3 Stefan Stahlhoff2 1Department of Vascular and Endovascular Surgery, University Hospital Münster, 2Department of Vascular Surgery, St Franziskus Hospital, Münster, 3Institute for Education and Student Affairs, University Hospital Münster, Münster, Germany Abstract: Peripheral arterial disease, particularly critical limb ischemia, is an area with urgent need for optimized therapies because, to date, vascular interventions often have limited life spans. In spite of initial encouraging technical success after femoropopliteal percutaneous transluminal angioplasty or stenting, postprocedural restenosis remains the major problem. The challenging idea behind the drug-coated balloon (DCB concept is the biological modification of the injury response after balloon dilatation. Antiproliferative drugs administered via DCBs or drug-eluting stents are able to suppress neointimal hyperplasia, the main cause of restenosis. This article reviews the results of DCB treatments of femoropopliteal and infrapopliteal lesions in comparison to standard angioplasty with uncoated balloons. A systematic literature search was performed in 1 medical journals (ie, MEDLINE, 2 international registers for clinical studies (ie, www.clinicaltrials.gov, and 3 abstracts of scientific sessions. Several controlled randomized trials with follow-up periods of up to 5 years demonstrated the efficacy of paclitaxel –DCB technology. However, calcified lesions seem to affect the efficacy of DCB. Combinations of preconditioning methods with DCBs showed promising results. Although the mechanical abrasion of calcium via atherectomy or laser ablation showed favorable periprocedural results, the long-term impact on restenosis and clinical outcome has to be demonstrated. Major advantages of the DCBs are the rapid delivery of drug at uniform concentrations with a single dose, their efficacy in areas wherein stents have been

  8. Preliminary experience with drug-coated balloon angioplasty in primary percutaneous coronary intervention

    Institute of Scientific and Technical Information of China (English)

    Hee; Hwa; Ho; Julian; Tan; Yau; Wei; Ooi; Kwok; Kong; Loh; Than; Htike; Aung; Nwe; Tun; Yin; Dasdo; Antonius; Sinaga; Fahim; Haider; Jafary; Paul; Jau; Lueng; Ong

    2015-01-01

    We evaluated the clinical feasibility of using drugcoated balloon(DCB) angioplasty in patients undergoingprimary percutaneous coronary intervention(PPCI). Between January 2010 to September 2014,89 STelevation myocardial infarction patients(83% male,mean age 59 ± 14 years) with a total of 89 coronary lesions were treated with DCB during PPCI. Clinical outcomes are reported at 30 d follow-up. Left anterior descending artery was the most common target vessel for PCI(37%). Twenty-eight percent of the patients had underlying diabetes mellitus. Mean left ventricular ejection fraction was 44% ± 11%. DCB-only PCI was the predominant approach(96%) with the remaining 4% of patients receiving bail-out stenting. Thrombolysis in Myocardial Infarction(TIMI) 3 flow was successfully restored in 98% of patients. An average of 1.2 ± 0.5 DCB were used per patient,with mean DCB diameter of 2.6 ± 0.5 mm and average length of 23.2 ± 10.2 mm. At 30-d follow-up,there were 4 deaths(4.5%). No patients experienced abrupt closure of the infarctrelated artery and there was no reported target-lesion failure. Our preliminary experience showed that DCB angioplasty in PPCI was feasible and associated with a high rate of TIMI 3 flow and low 30-d ischaemic event.

  9. Drug-eluting balloon catheters for lower limb peripheral arterial disease: the evidence to date

    Science.gov (United States)

    Barkat, Mohamed; Torella, Francesco; Antoniou, George A

    2016-01-01

    A significant proportion of patients with severe lower limb peripheral arterial disease require revascularization. Over the past decade, an endovascular-first approach even for complex disease has gained widespread use among vascular specialists. An important limitation of percutaneous transluminal balloon angioplasty or stenting remains the occurrence of restenosis. Drug-coated balloons have emerged as an exciting technology developed to overcome the limitations of standard balloon angioplasty and stenting. Drug-eluting devices inhibit neointimal growth of vascular smooth muscle cells with the potential of preventing restenosis. This review provides a synopsis of the up-to-date evidence on the role of drug-coated balloons in the treatment of lower limb peripheral arterial disease. Bibliographic searches were conducted using MEDLINE, EMBASE, and the Cochrane Library electronic database. Eleven randomized clinical trials, two systematic reviews, and a published registry providing the best available evidence were identified. Current evidence suggests that angioplasty with drug-coated balloon is reliable, safe, and efficient in increasing patency rates and reducing target lesion revascularization and restenosis. However, it remains unknown whether these improved results can translate into beneficial clinical outcomes, as current randomized clinical trials have failed to demonstrate a significant benefit in limb salvage and mortality. Further randomized trials focusing on clinical and functional outcomes of drug-eluting balloons and on cost versus clinical benefit are required. PMID:27274265

  10. Bailout techniques for failed coronary angioplasty using 6 French guiding catheters.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1994-08-01

    Coronary angioplasty (PTCA) through 6 French (F) guiding catheters is feasible, although acute or threatened closure following coronary artery dissections may occur. This report describes our experience with the treatment of suboptimal results in 13 patients from a population of 144 patients who had PTCA through 6F guiding catheters. Patients were treated with a new low profile autoperfusion catheter (ACS, Flowtrack40) or with Palmaz Schatz stents, advanced through 6F guiding catheters. PTCA was performed via the radial artery in 11 pts (85%) or via the femoral artery in two patients (15%). In two patients, (15%) PTCA was complicated by an dissection associated with complete loss of flow (TIMI 0) and a dissection was considered to lead to abrupt closure in the remaining 11 patients (85%), despite the presence of normal flow. A Flow-track40 perfusion catheter was successfully applied in three of four patients. In one patient a persisting dissection after restoration of flow by a perfusion catheter was treated with three Palmaz Schatz stents. Implantation of Palmaz Schatz stents was attempted as primary technique in nine patients. In one patient the stent could not cross a dissection in the proximal LAD via the radial artery. With an 8F system via the femoral artery, two stents could successfully be deployed with the stent delivery system. In another patient the stent could not be advanced across a subtotal residual stenosis in a tortuous left anterior descending coronary artery. Despite normal antegrade flow and emergency bypass surgery, this patient developed a non-Q-myocardial infarction. In the remaining patients, the clinical course was uncomplicated.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Deflation of the ′obstinate′ Foley′s urinary catheter balloon : a new technique.

    Directory of Open Access Journals (Sweden)

    Ramakantan R

    1989-01-01

    Full Text Available We have successfully deflated "obstinate" Foley′s urinary catheter balloons in 15 cases in the last six months with the help of a simple bedside procedure using an angiographic guide-wire.

  12. Is routine stenting for acute myocardial infarction superior to balloon angioplasty? A randomised comparison in a large cohort of unselected patients

    NARCIS (Netherlands)

    Suryapranata, H; De Luca, G; van't Hof, AWJ; Ottervanger, JP; Hoorntje, JCA; Gosselink, ATM; Zijlstra, F; de Boer, MJ; Dambrink, Jan Hendrik Everwijn

    2005-01-01

    Objective: To evaluate the impact of routine stenting, compared with balloon angioplasty, in unselected patients presenting with ST segment elevation myocardial infarction (STEMI). Design: Randomised trial. Setting: Tertiary referral centre. Participants: All patients presenting with STEMI randomly

  13. Balloon-assisted guide catheter positioning to overcome extreme cervical carotid tortuosity: technique and case experience

    OpenAIRE

    Peeling, Lissa; Fiorella, David

    2013-01-01

    Background and significance We describe a method by which to efficiently and atraumatically achieve distal positioning of a flexible guiding catheter beyond extreme cervical tortuosity using a hypercompliant temporary occlusion balloon. Methods A retrospective review of a prospective neuroendovascular database was used to identify cases in which a hypercompliant balloon catheter (Hyperform or Hyperglide, ev3/Covidien, Irvine, California, USA; Scepter or Scepter XC, Alisa Viejo, California, US...

  14. Transradial artery coronary angioplasty.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J; de Melker, E

    1995-01-01

    This study explored the feasibility and safety of percutaneous coronary balloon angioplasty (PTCA) with miniaturized PTCA equipment via the radial artery. Coronary angioplasty (PTCA) via the femoral or brachial arteries may be associated with rare vascular complications such as bleeding and damage to the artery and adjacent structures. It was postulated that PTCA via the radial artery with miniaturized angioplasty equipment is feasible and that no major puncture site-related complications occur because hemostasis is obtained easily and because no major structures are near the radial artery. With double blood supply to the hand, radial artery occlusion is well tolerated. In 100 patients with collateral blood supply to the right hand, PTCA was attempted with 6F guiding catheters and rapid-exchange balloon catheters for exertional angina (87 patients) or nonexertional angina (13 patients). Angioplasty was attempted in 122 lesions (type A n = 67 [55%], Type B n = 37 [30%], and type C n = 18 [15%]). Pre- and post-PTCA computerized quantitative coronary analysis was performed. Radial artery function and structure were assessed clinically and with Doppler and two-dimensional ultrasound on the day of discharge. Coronary catheterization via the radial artery was successful in 94 patients (94%). The 6 remaining patients had successful PTCA via the femoral artery (n = 5) or the brachial artery (n = 1). Procedural success (120 of 122 lesions) was achieved in 92 patients (98%) via the radial artery and in 98 patients of the total study population.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Stent-Apposition Salvage of an Anterior Tibial Artery After Inadvertent Angioplasty Balloon Retention During CTO Revascularization.

    Science.gov (United States)

    Choudry, R; Deutsch, E; Durinka, J; Dhir, T

    2016-01-01

    Progressive improvement in the ability to treat complete total occlusions in the tibial level arterial circulation have made it possible to revascularize patients with critical limb ischemia. A 59 year old male presented with a complete total occlusion of his anterior tibial artery with distal reconstitution through peroneal artery collaterals. During attempted angioplasty a balloon was retained within the patent portion of the target vessel. Two 3.0 mm drug eluting coronary stents were deployed across the length of the balloon with excellent luminal preservation. Successful CTO revascularization was completed and a strong dorsalis pedis artery pulse was restored following intervention.

  16. Combining balloon-assisted tracking and sheathless guiding catheter: unloosening the Gordian knot.

    Science.gov (United States)

    D'Amario, Domenico; Paraggio, Lazzaro; Porto, Italo

    2015-01-01

    In a patient with a small-calibre radial artery and a 360° radio-ulnar loop, we combined the balloon-assisted tracking (BAT) technique (used to track a catheter trough the loop) with the use of a 6.5FPB sheathless guiding catheter, in order to allow the extensive catheter manipulations needed for PCI despite the ongoing artery spasm. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty. A study in the atherosclerotic rabbit.

    Science.gov (United States)

    Sarembock, I J; LaVeau, P J; Sigal, S L; Timms, I; Sussman, J; Haudenschild, C; Ezekowitz, M D

    1989-10-01

    To evaluate the effect of balloon size and inflation pressure on acute and subsequent outcome following balloon angioplasty (BA), 70 New Zealand White rabbits with bilateral femoral atherosclerosis were assigned to four groups: group 1, oversized balloon, low inflation pressure (n = 35 vessels; balloon size, 3.0 mm/inflation pressure, 5 atm); group 2, oversized balloon, high inflation pressure (n = 36; 3.0 mm/10 atm); group 3, appropriate size, low inflation pressure (n = 17; 2.5 mm/5 atm); and group 4, appropriate size balloon, high inflation pressure (n = 19; 2.5 mm/10 atm). Angiograms were obtained before, 10 minutes after, and 28 days after BA and read by two blinded observers using electronic calipers. The in vivo balloon-to-vessel ratio was measured for each group. There were eight non-BA controls. Rabbits were sacrificed either immediately (n = 34) or at 28 days after BA (n = 36), with the femoral vessels pressure perfused for histologic and morphometric analysis. The latter was performed at 28 days only. Absolute angiographic diameters increased in all groups immediately after BA (p less than 0.01). Acute angiographic success, defined as greater than 20% increase in luminal diameter, was higher using high inflation pressure (group 2, 32/36 [89%] and group 4, 16/19 [84%] vs. group 1, 23/35 [66%] and group 3, 9/17 [53%]; p less than 0.05). A 3.0-mm balloon resulted in significant oversizing irrespective of inflation pressure (balloon-to-vessel ratio, 1.5 +/- 0.1 vs. 1.1 +/- 0.1 to 1, for the 2.5-mm balloon). Vessels exposed to high inflation pressure had a significantly higher incidence of mural thrombus, dissection (p less than 0.01), and medial necrosis versus low pressure (p less than 0.05). At 28 days, the rates of restenosis (defined as greater than 50% loss of initial gain) were 14/20 (70%), 11/16 (69%), 5/10 (50%), and 5/10 (50%) for groups 1 through 4 (p = NS; a trend in favor of the groups using an oversized balloon). There was an increase in the

  18. Balloon Dilatation for Removal of an Irretrievable Permanent Hemodialysis Catheter: The Safest Approach.

    Science.gov (United States)

    Garcarek, Jerzy; Gołębiowski, Tomasz; Letachowicz, Krzysztof; Kusztal, Mariusz; Szymczak, Maciej; Madziarska, Katarzyna; Jakuszko, Katarzyna; Zmonarski, Sławomir; Guziński, Maciej; Weyde, Wacław; Klinger, Marian

    2016-05-01

    Long-term hemodialysis catheter dwell time in the central vein predisposes to fibrin sheath development, which subsequently causes catheter malfunction or occlusion. In very rare cases, the catheter can be overgrown with fibrin and rigidly connected with the vein or heart structures. This makes its removal almost impossible and dangerous because of the possibility of serious complications, namely vein and heart wall perforation, bleeding, or catheter abruption in deep tissues. We describe two cases in which standard retrieval of long-term catheters was not possible. Balloon dilatation of catheter lumens was successfully used to increase the catheter diameter with simultaneous tearing of the fibrin sheath surrounding it. This allowed the catheter to be set free safely. Based on this experience, we present recent literature and our point of view. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Deep sea water prevents balloon angioplasty-induced hyperplasia through MMP-2: an in vitro and in vivo study.

    Science.gov (United States)

    Li, Pei-Chuan; Pan, Chun-Hsu; Sheu, Ming-Jyh; Wu, Chin-Ching; Ma, Wei-Fen; Wu, Chieh-Hsi

    2014-01-01

    Major facts about the development of restenosis include vascular smooth muscle cells (VSMCs) proliferation and migration. A previous study showed that in vitro treatment with magnesium chloride has the potential to affect the proliferation and migration of VSMCs. Magnesium is the major element in deep sea water (DSW) and is a biologically active mineral. It is unclear whether DSW intake can prevent abnormal proliferation and migration of VSMCs as well as balloon angioplasty-induced neointimal hyperplasia. Thus, we attempted to evaluate the anti-restenotic effects of DSW and its possible molecular mechanisms. Several concentrations of DSW, based on the dietary recommendations (RDA) for magnesium, were applied to a model of balloon angioplasty in SD rats. The results showed that DSW intake markedly increased magnesium content within the vascular wall and reduced the development of neointimal hyperplasia. The immunohistochemical analysis also showed that the expression of proteins associated with cell proliferation and migration were decreased in the balloon angioplasty groups with DSW supplement. Furthermore, in vitro treatment with DSW has a dose-dependent inhibitory effect on serum-stimulated proliferation and migration of VSMCs, whose effects might be mediated by modulation of mitogen-activated protein kinase (MAPK) signaling and of the activity of matrix metalloproteinase-2 (MMP-2). Our study suggested that DSW intake can help prevent neointimal hyperplasia (or restenosis), whose effects may be partially regulated by magnesium and other minerals.

  20. Deep sea water prevents balloon angioplasty-induced hyperplasia through MMP-2: an in vitro and in vivo study.

    Directory of Open Access Journals (Sweden)

    Pei-Chuan Li

    Full Text Available Major facts about the development of restenosis include vascular smooth muscle cells (VSMCs proliferation and migration. A previous study showed that in vitro treatment with magnesium chloride has the potential to affect the proliferation and migration of VSMCs. Magnesium is the major element in deep sea water (DSW and is a biologically active mineral. It is unclear whether DSW intake can prevent abnormal proliferation and migration of VSMCs as well as balloon angioplasty-induced neointimal hyperplasia. Thus, we attempted to evaluate the anti-restenotic effects of DSW and its possible molecular mechanisms. Several concentrations of DSW, based on the dietary recommendations (RDA for magnesium, were applied to a model of balloon angioplasty in SD rats. The results showed that DSW intake markedly increased magnesium content within the vascular wall and reduced the development of neointimal hyperplasia. The immunohistochemical analysis also showed that the expression of proteins associated with cell proliferation and migration were decreased in the balloon angioplasty groups with DSW supplement. Furthermore, in vitro treatment with DSW has a dose-dependent inhibitory effect on serum-stimulated proliferation and migration of VSMCs, whose effects might be mediated by modulation of mitogen-activated protein kinase (MAPK signaling and of the activity of matrix metalloproteinase-2 (MMP-2. Our study suggested that DSW intake can help prevent neointimal hyperplasia (or restenosis, whose effects may be partially regulated by magnesium and other minerals.

  1. Thermal laser-assisted angioplasty of renal artery stenosis for renovascular hypertension.

    Science.gov (United States)

    Tani, M; Mizuno, K; Midorikawa, H; Igari, T; Egawa, M; Niimura, S; Fukuchi, S; Hoshino, S

    1993-01-01

    Percutaneous transluminal laser-assisted angioplasty of a renal artery stenosis was performed in a 16-year-old woman with renovascular hypertension. The stenotic portion of the renal artery was predilated by delivering Nd-YAG laser energy to the terminal tip of a laser catheter. Although the luminal diameter did not increase sufficiently with laser angioplasty alone, it allowed passage of the balloon catheter and subsequent successful balloon angioplasty. Immediately after dilatation, the patient's blood pressure fell to normal, and plasma renin activity decreased. There were no serious complications. Thermal laser angioplasty seems to be an effective adjunct technique for the treatment of severe renal artery stenosis which does not allow initial passage of a balloon catheter.

  2. Reduction of Intimal Hyperplasia in Injured Rat Arteries Promoted by Catheter Balloons Coated with Polyelectrolyte Multilayers that Contain Plasmid DNA Encoding PKCδ

    Science.gov (United States)

    Bechler, Shane L.; Si, Yi; Yu, Yan; Ren, Jun; Liu, Bo; Lynn, David M.

    2012-01-01

    New therapeutic approaches that eliminate or reduce the occurrence of intimal hyperplasia following balloon angioplasty could improve the efficacy of vascular interventions and improve the quality of life of patients suffering from vascular diseases. Here, we report that treatment of arteries using catheter balloons coated with thin polyelectrolyte-based films (‘polyelectrolyte multilayers’, PEMs) can substantially reduce intimal hyperplasia in an in vivo rat model of vascular injury. We used a layer-by-layer (LbL) process to coat the surfaces of inflatable catheter balloons with PEMs composed of nanolayers of a cationic poly(β-amino ester) (polymer 1) and plasmid DNA (pPKCδ) encoding the δ isoform of protein kinase C (PKCδ), a regulator of apoptosis and other cell processes that has been demonstrated to reduce intimal hyperplasia in injured arterial tissue when administered via perfusion using viral vectors. Insertion of balloons coated with polymer 1/pPKCδ multilayers into injured arteries for 20 min resulted in local transfer of DNA and elevated levels of PKCδ expression in the media of treated tissue 3 days after delivery. IFC and IHC analysis revealed these levels of expression to promote downstream cellular processes associated with up-regulation of apoptosis. Analysis of arterial tissue 14 days after treatment revealed polymer 1/pPKCδ-coated balloons to reduce the occurrence of intimal hyperplasia by ~60% compared to balloons coated with films containing empty plasmid vectors. Our results demonstrate the potential therapeutic value of this nanotechnology-based approach to local gene delivery in the clinically important context of balloon-mediated vascular interventions. These PEM-based methods could also prove useful for other in vivo applications that require short-term, surface-mediated transfer of plasmid DNA. PMID:23069712

  3. Balloon pulmonary angioplasty: applicability of C-Arm CT for procedure guidance

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B. [Department for Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover (Germany); Renne, Julius; Wacker, Frank K.; Meyer, Bernhard C. [Department for Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany); Hoeper, Marius M.; Olsson, Karen M. [Clinic for Pneumology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover (Germany)

    2016-11-15

    To investigate the feasibility of and compare two C-Arm CT (CACT) guidance methods during balloon pulmonary angioplasty (BPA). Forty-two BPAs [27 CTEPH patients (nine males, 70 ± 14y)] targeting 143 pulmonary arteries were included. Twenty-two BPAs were guided by contrast-enhanced CACT acquired immediately before BPA (G3D). In another 20 BPAs (G2D), two orthogonal fluoroscopy images of the chest where acquired to compute a registration of a previously acquired CACT. Volume rendering-based graphic representations (VRT guidance) were generated indicating the origin and course of the vessels. Based on VRT guidance, the intervention was planned. Procedure durations and radiation exposure data were compared between the two groups (Wilcoxon test). The overall intervention time was approximately 2 h in both groups (p = 0.31). BPA was successfully performed in G3D 91 % and G2D 94 %. No significant difference was found concerning the mean dose area product (DAP) related to fluoroscopy (p = 0.38), while DAP related to DSA was slightly higher in G3D (p = 0.048). Overall, DAP was significantly higher in G3D (p = 0.002). The use of CACT for procedure guidance in patients undergoing BPA is feasible and accurate. Image fusion of a pre-acquired CACT can be used to decrease radiation exposure due to multiple BPA sessions. (orig.)

  4. Outcome of patients undergoing balloon angioplasty in the two months prior to noncardiac surgery.

    Science.gov (United States)

    Brilakis, Emmanouil S; Orford, James L; Fasseas, Panayotis; Wilson, Stephanie H; Melby, Steven; Lennon, Ryan J; Berger, Peter B

    2005-08-15

    We report on the incidence of adverse cardiac events in 350 patients who underwent noncardiac surgery within 2 months of successful balloon angioplasty (BA) at our institution between 1988 and 2001. Three patients died perioperatively (n = 1) or had myocardial infarction (n = 2) (0.9%, 95% confidence interval [CI] 0.2% to 2.5%), which is a lower incidence than that reported for patients undergoing noncardiac surgery after stenting (3.9% to 32%). One patient died, and 2 had a nonfatal myocardial infarction. All 3 (1.6%, 95% CI 0.3% to 4.6%) were among the 188 patients who underwent surgery within 2 weeks of BA. Repeat target vessel revascularization was performed in 10 patients (2.9%, 95% CI 1.4% to 5.2%): in 3 (1.6%, 95% CI 0.3% to 4.6%) of 188 patients who underwent surgery within 2 weeks of BA and in 7 (5.1%, 95% CI 2.1% to 10.2%) of 138 patients who underwent surgery within 3 to 7 weeks of BA. Therefore, in patients in whom percutaneous coronary revascularization is required before noncardiac surgery, BA appears to be safe, especially in patients who need to undergo surgery early after percutaneous coronary intervention.

  5. Percutaneous recanalization and balloon angioplasty of congenital isolated local atresia of the aortic isthmus in adults.

    Science.gov (United States)

    Joseph, G; Mandalay, A; Rajendiran, G

    2001-08-01

    Congenital isolated local atresia of the aortic isthmus is anatomically similar and morphogenetically related to congenital coarctation of the aorta and was encountered in 4 out of 26 consecutive adult patients selected for coarctation angioplasty at our center. Anterograde recanalization of the atresia was safely and successfully accomplished in all four patients, using a brachial approach. Balloon dilation in the four patients, with ancillary stent implantation in one patient, resulted in reduction of translesion gradient from 84 +/- 11 mm Hg to 9 +/- 7 mm Hg without complications. Angiography in the three non-stented patients after a mean follow-up of 13 months showed no evidence of restenosis, dissection or aneurysm formation, though one patient had mild dilatation of the posterior aspect of the aortic isthmus. The clinical presentation of patients with isolated local aortic atresia, and their short- to mid-term response to percutaneous treatment, is similar to that of patients with isolated severe coarctation of aorta. Copyright 2001 Wiley-Liss, Inc.

  6. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, Nicholas, E-mail: nicholas.chalmers@cmft.nhs.uk [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Walker, Paul T. [James Cook University Hospital, Department of Radiology (United Kingdom); Belli, Anna-Maria [St. George' s Healthcare NHS Trust, Department of Radiology (United Kingdom); Thorpe, Anthony P. [Aberdeen Royal Infirmary, Department of Radiology (United Kingdom); Sidhu, Paul S. [King' s College Hospital, Department of Radiology (United Kingdom); Robinson, Graham [Hull Royal Infirmary, Department of Radiology (United Kingdom); Ransbeeck, Mariella van [Johnson and Johnson Medical NV/SA, Cordis (Belgium); Fearn, Steven A. [Johnson and Johnson Medical Ltd., Cordis (United Kingdom)

    2013-04-15

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  7. Preparation and characterisation of polyamide 11/montmorillonite (MMT) nanocomposites for use in angioplasty balloon applications

    Energy Technology Data Exchange (ETDEWEB)

    Halim, Khairul Anwar A. [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland); School of Materials Engineering, Universiti Malaysia Perlis, Perlis (Malaysia); Farrell, Joseph B. [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland); Kennedy, James E., E-mail: jkennedy@ait.ie [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland)

    2013-12-16

    With increased demands on catheter balloon functionality, there is an emphasis to blend new materials which can improve mechanical performance. Polymer nanocomposites were prepared by melt blending polyamide 11 (PA 11) with organically modified montmorillonite nanoclay. The effects of incorporating the nanoclay on the short-term mechanical properties of PA 11 were assessed using a design of experiments (DoEs) approach. X-ray diffraction (XRD), transmission electron microscopy (TEM), differential scanning calorimetry (DSC) and dynamic mechanical thermal analysis techniques (DMA) were used to characterise the morphology of the nanocomposites. Design of experiments studies revealed that the optimum nanocomposites properties can be achieved by carefully controlling the melt compounding parameters. XRD and TEM data proved that exfoliated clay morphologies existed within the matrix at low clay loading (2%). Whereas the interaction between the polymer matrix and nanoclay was quantified in the DMA spectra, showed a significant increase in storage modulus (up to 80%). The reinforcing effect of nanoclay within the PA 11 was further investigated using mechanical testing, where significant increases in the ultimate tensile strength and strain at break of reinforced tri-layer balloon tubing were observed. - Highlights: • TEM reveals the coexistence of exfoliated and intercalated nanostructures. • Isothermal crystallisation studies found that the nano-clays reduced the crystallisation time. • Significant increase in the storage modulus was due to the reinforcing effect of the nano-clay platelets. • It was observed that the activation energy values decreased due to the presence of nanoclay.

  8. Minimally invasive wire-guided balloon catheter puncture for voice prosthesis insertion.

    Science.gov (United States)

    Tobed Secall, Marc; Bores, Toni; Sambola, Ignacio; Lop, Joan; García Rica, Eduardo; Lluansi, Jordi

    2017-07-01

    Tracheoesophageal puncture is an effective and reliable method for voice restoration after total laryngectomy that may be performed as a primary or secondary procedure. We describe our technique for secondary tracheoesophageal puncture using a wire-guided balloon catheter in an office setting. A 72-year-old patient with a total laryngectomy performed 2 years ago was selected for wire-guided balloon catheter puncture and voice prosthesis insertion. Successful tracheoesophageal puncture placement was achieved without complications and the patient tolerated the procedure well. The voice result was satisfactory and immediate. We conclude that balloon catheter tracheoesophageal puncture can be a simple and safe option for secondary voice prosthesis insertion in total laryngectomy for selected patients. It can be performed in an office setting using only local anesthetic for secondary puncture. © 2017 Wiley Periodicals, Inc.

  9. Transcervical double-balloon catheter as an alternative and salvage method for medical termination of pregnancy in midtrimester

    Directory of Open Access Journals (Sweden)

    Yi-An Tu

    2017-02-01

    Conclusion: There was no significant additional benefit of using a double-balloon catheter in midtrimester termination of pregnancy, although the technique was considered simple and generally well-tolerated. Placing a transcervical double-balloon catheter could be the primary method, or one of the alternative medical methods if the patient and/or obstetrician prefers no operation.

  10. Management of postpartum hemorrhage with intrauterine balloon tamponade using a condom catheter in an Egyptian setting.

    Science.gov (United States)

    Kandeel, Mohamed; Sanad, Zakaria; Ellakwa, Hamed; El Halaby, Alaa; Rezk, Mohamed; Saif, Ibrahim

    2016-12-01

    To evaluate uterine balloon tamponade using a condom catheter for the management of early postpartum hemorrhage (PPH). In a prospective observational study at Menoufia University Hospital, Shebin Elkom, Egypt, women with early PPH were enrolled between May 2011 and September 2012. Uterine balloon tamponade with a condom catheter was applied in women who were unresponsive to uterotonics and bimanual compression; patients with successful catheter placement were included in analyses. The primary outcome was successful control (reduction or cessation) of bleeding. A condom catheter was successfully placed for 50 of the 151 women enrolled. The overall success rate of the procedure was 96% (48/50). The condom catheter was successful in all 28 cases of atonic PPH after vaginal or cesarean delivery. It successfully controlled PPH due placental site bleeding in 20 (91%) of 22 patients with placenta previa and a well-contracted uterus. Condom balloon catheter was found to effectively control PPH. The procedure is simple, inexpensive, and safe, and can preserve reproductive capacity, as well as saving the life of the mother. ClinicalTrials.gov:NCT02672891. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  11. New developments in the clinical use of drug-coated balloon catheters in peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Naghi J

    2016-06-01

    Full Text Available Jesse Naghi, Ethan A Yalvac, Ali Pourdjabbar, Lawrence Ang, John Bahadorani, Ryan R Reeves, Ehtisham Mahmud, Mitul Patel Division of Cardiovascular Medicine, Sulpizio Cardiovascular Center, University of California, San Diego, CA, USA Abstract: Peripheral arterial disease (PAD involving the lower extremity is a major source of morbidity and mortality. Clinical manifestations of PAD span the spectrum from lifestyle limiting claudication to ulceration and gangrene leading to amputation. Advancements including balloon angioplasty, self-expanding stents, drug-eluting stents, and atherectomy have resulted in high technical success rates for endovascular therapy in patients with PAD. However, these advances have been limited by somewhat high rates of clinical restenosis and clinically driven target lesion revascularization. The recent introduction of drug-coated balloon technology shows promise in limiting neointimal hyperplasia induced by vascular injury after endovascular therapies. This review summarizes the contemporary clinical data in the emerging area of drug-coated balloons. Keywords: drug-coated balloons, endovascular, percutaneous transluminal angioplasty, paclitaxel, peripheral arterial disease

  12. Balloon angioplasty of coarctation of the aorta: a safe alternative for surgery in adults: immediate and mid-term results.

    Science.gov (United States)

    Koerselman, J; de Vries, H; Jaarsma, W; Muyldermans, L; Ernst, J M; Plokker, H W

    2000-05-01

    Patients with coarctation of the aorta can be treated either with surgery or with balloon angioplasty. So far, the last method has proved to be successful in children, but results of this treatment in (young) adults are virtually unknown. The aim of this study was to evaluate the immediate and mid-term follow-up results of balloon angioplasty of native coarctation in (mainly young) adults. Coarctation of the aorta was diagnosed by means of ultrasound or angiography, and defined as a stenosis with a pressure gradient greater than 20 mm Hg. The balloon angioplasty-procedure was carried out under complete anesthesia, and was considered to be successful, if the pressure gradient was reduced to less than 20 mm Hg. Nineteen consecutive adults (12 males, 7 females; aged 14-67 years, median 29) with native coarctation were treated from 1995-99. Mean pressure gradient decreased from 49.3+/- 20.8 to 4.8+/-8.2 mm Hg (P<0.0001). One patient showed a suboptimal result with a residual pressure gradient of 28 mm Hg. In one other patient a stent was placed on request of the referring physician. Follow-up was 100% complete and ranged from 3-47 months (mean 20.2+/- 12.9). At 1-year follow-up mean systolic blood pressure was reduced from 159.4+/-19.5 to 132.5+/-17.6 mm Hg (n = 18; P<0.0001), and mean ankle-arm pressure index improved from 0.73+/-0.09 to 0.96+/-0.05 (n = 18; P<0.0001). Anti-hypertensive medication could either be reduced or stopped in 7 patients (53.8%). With ultrasound or angiography or MRI, no patients had signs of aneurysm formation or worsening restenosis during follow-up. In adult patients with uncomplicated native coarctation of the aorta, balloon angioplasty (without stenting) would seem to be an excellent and safe alternative for surgery. In our hospital it has completely replaced surgical correction in such patients.

  13. Removal of nasal foreign bodies with a Fogarty biliary balloon catheter.

    Science.gov (United States)

    Nandapalan, V; McIlwain, J C

    1994-09-01

    Twenty-five children with a range of nasal foreign bodies, which were not easily amenable to anterior instrumental extraction, were considered for this study. These foreign bodies were removed by the use of a Fogarty biliary balloon catheter (Intimax) successfully in 23 children. In two children no foreign body was found. None of the children had any complications. This is a safe procedure which can be performed as an out-patient. Whilst the cost of the catheter may appear expensive, in comparison to the cost of admission for removal of similarly sited foreign bodies under general anaesthesia, the catheter fares favourably.

  14. Use of a balloon catheter in management of the pelvic space following laparoscopic abdominoperineal excision

    DEFF Research Database (Denmark)

    Bulut, Orhan; Rasmussen, Helle B; Jess, Per

    2012-01-01

    patients (26.6%) had a deep pelvic abscess, which required surgical drainage. The median time of perineal wound healing was 3 months (range 2-8). The median follow-up time was 36 months (range18-60). None of the patients developed perineal hernia and intestinal obstruction in the follow-up period. One...... procedure and a Foley catheter Ch. 24 was inserted through the right lower port under direct vision. The balloon of the catheter, placed in the presacral space, was filled with 50 ml sterile saline and connected to passive drainage. The catheter was removed 10 days postoperatively. Results: This technique...

  15. Effect and outcome of balloon angioplasty and stenting of the iliac arteries evaluated by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K J; Rasmussen, John Bøje Grønvall; Just, S;

    1999-01-01

    To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency.......To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency....

  16. Prolonged high-pressure balloon angioplasty of femoropopliteal lesions:Impact on stent implantation rate and mid-term outcome

    Institute of Scientific and Technical Information of China (English)

    Gianluca Rigatelli; Mariano Palena; Paolo Cardaioli; Fabio dellAvvocata; Massimo Giordan; Dobrin Vassilev; Marco Manzi

    2014-01-01

    Objectives To assess the impact on stent implantation rate and mid-term outcomes of prolonged high pressure angioplasty of femoropopliteal lesions. Methods We retrospectively enrolled 620 consecutive patients from January 2011 to December 2011 (75.6 ±12.3 years, 355 males, 76.5%in Rutherford class 5-6), referred for critical limb ischemia and submitted to prolonged high-pressure angioplasty of femoropopliteal lesions. The definition of prolonged high-pressure angioplasty includes dilation to at least 18 atm for at least 120 s. Proce-dural data, and clinical and instrumental follow-up were analyzed to assess stent implantation rate and mid-term outcomes. Results The preferred approach was ipsilateral femoral antegrade in 433/620 patients (69.7%) and contralateral cross-over in 164/620 (26.4%) and pop-liteal retrograde+femoral antegrade in 23/620 (3.7%). Techniques included subintimal angioplasty in 427/620 patients (68.8%) and endolu-minal angioplasty in 193/620 patients (31.2%). The prolonged high pressure balloon angioplasty procedure was successful in 86.2%(minor intra-procedural complications rate 15.7%), stent implantation was performed in 74 patients (11.9%), with a significant improvement of ankle-brachial index (0.29 ±0.6 vs. 0.88 ±0.3, P<00.1) and Rutherford class (5.3 ±0.8 vs. 0.7 ±1.9, P<0.01), a primary patency rate of 86.7%, restenosis of 18.6%on Doppler ultrasound and a target lesion revascularization of 14.8%at a mean follow-up of 18.1 ±6.4 months (range 1-24 months). Secondary patency rate was 87.7%. Conclusions Prolonged high pressure angioplasty of femoropopliteal lesions appears to be safe and effective allowing for an acceptable patency and restenosis rates on mid-term.

  17. A system for visualization and automatic placement of the endoclamp balloon catheter

    NARCIS (Netherlands)

    Furtado, H.; Stüdeli, T.; Sette, M.; Samset, E.; Gersak, B.

    2010-01-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and ke

  18. A system for visualization and automatic placement of the endoclamp balloon catheter

    NARCIS (Netherlands)

    Furtado, H.; Stüdeli, T.; Sette, M.; Samset, E.; Gersak, B.

    2010-01-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and

  19. Balloon catheter dilation technology combined with a fibrolaryngoscope to treat a maxillary sinus cyst.

    Science.gov (United States)

    Xiao, Jianxin; Chen, Junming; Wang, Yuejian

    2016-02-01

    A prospective randomized controlled study was conducted to investigate the effect of balloon catheter dilation technology combined with a fibrolaryngoscope in the treatment of a maxillary sinus cyst. The clinical data of 14 cases (19 maxillary sinuses) with balloon catheter dilation technology combined with a fibrolaryngoscope to remove sinus cysts (balloon group) and 16 cases (23 maxillary sinuses) with conventional nasal endoscopic sinus surgery to remove sinus cysts (conventional group) were analyzed. All cases have completed the preoperative and postoperative SNOT-20, nasal endoscopy and coronal sinus CT scan. Lund-Kennedy endoscopic and Lund-Mackay CT scan staging scores were recorded. All patients were followed up for 24 weeks after the operation. The SNOT-20 scores, Lund-Kennedy endoscopic and Lund-Mackay CT scan staging scores were lower in the balloon group than that in the control group. Balloon catheter dilation technology combined with a fibrolaryngoscope can effectively preserve the function and structures of the nasal cavity and sinus, making it a good choice in the treatment of a retention cyst of the maxillary sinus.

  20. Low-pressure balloon angioplasty with adjuvant pharmacological therapy in patients with acute ischemic stroke caused by intracranial arterial occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Raul G. [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Neurosurgery, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Neurology, Neurocritical Care and Vascular Neurology Section, Boston, MA (United States); Massachusetts General Hospital, Boston, MA (United States); Schwamm, Lee H.; Buonanno, Ferdinando S.; Koroshetz, Walter J. [Massachusetts General Hospital, Harvard Medical School, Department of Neurology, Neurocritical Care and Vascular Neurology Section, Boston, MA (United States); Yoo, Albert J.; Rabinov, James D.; Pryor, Johnny C.; Hirsch, Joshua A. [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Neurosurgery, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States)

    2008-04-15

    The use of coronary balloons in the cerebral vasculature is limited due to their poor trackability and increased risk of vessel injury. We report our experience using more compliant elastomer balloons for thrombus resistant to intraarterial (IA) pharmacological and mechanical thrombolysis in acute stroke. We retrospectively analyzed 12 consecutive patients with an occluded intracranial artery treated with angioplasty using a low-pressure elastomer balloon. Angiograms were graded according to the Thrombolysis in Cerebral Infarction (TICI) and Qureshi grading systems. Outcomes were categorized as independent (modified Rankin scale, mRS, score {<=}2), dependent (mRS score 3-5), or dead (mRS score 6). Included in the study were 12 patients (mean age 66{+-}17 years, range 31-88 years; mean baseline National Institutes of Health stroke scale score 17{+-}3, range 12-23). The occlusion sites were: internal carotid artery (ICA) terminus (five patients, including two concomitant cervical ICA occlusions), M1 segment (two patients), and basilar artery (two patients). Pharmacological treatment included intravenous (IV) t-PA only (two patients), IA urokinase only (nine patients), both IV t-PA and IA urokinase (one patient), and IV and/or IA eptifibatide (eight patients). Mean time to treatment was 5.9{+-}3.9 h (anterior circulation) and 11.0{+-}7.2 h (posterior circulation). Overall recanalization rate (TICI grade 2/3) was 91.6%. Procedure-related morbidity occurred in one patient (distal posterior inferior cerebellar artery embolus). There were no symptomatic hemorrhages. Outcomes at 90 days were independent (five patients), dependent (three patients) and dead (four patients, all due to progression of stroke with withdrawal of care). Angioplasty of acutely occluded intracranial arteries with low-pressure elastomer balloons results in high recanalization rates with an acceptable degree of safety. Prior use of thrombolytics may increase the chances of recanalization, and

  1. Efficacy of a coaxial system with a compliant balloon catheter for navigation of the Penumbra reperfusion catheter in tortuous arteries: technique and case experience.

    Science.gov (United States)

    Takahira, Kazuki; Kataoka, Taketo; Ogino, Tatsuya; Endo, Hideki; Nakamura, Hirohiko

    2017-04-01

    OBJECTIVE The authors describe a method by which they easily and atraumatically navigate a large-bore reperfusion catheter of the Penumbra system to an embolus by using a coaxial system with a compliant balloon catheter in patients with tortuous arteries. METHODS A retrospective review of the prospective endovascular database was performed to identify cases in which a coaxial system with a compliant balloon catheter (Scepter C, MicroVention/Terumo; or TransForm C, Stryker Neurovascular) and a large-bore reperfusion catheter of the Penumbra system (Penumbra, Inc.) was used. The authors achieved a stable guiding sheath position and delivered the coaxial system with a compliant balloon catheter and a large-bore reperfusion catheter. Then, the balloon was inflated somewhat when the distal tip of the balloon was slightly advanced from the tip of the reperfusion catheter, and together the coaxial system was advanced to an embolus over a 0.014-in guidewire, even around the corner. When the distal tip of the balloon catheter reached the embolus, the authors deflated the balloon and navigated the large-bore reperfusion catheter to the embolus. Finally, the aspiration of the embolus with the Penumbra MAX pump was begun. RESULTS Between May 2014 and September 2015, the authors used this technique in 17 cases: 16 cases of middle cerebral artery occlusion (including 5 cases of internal carotid artery occlusion) and 1 case of basilar artery occlusion (age range 36-88 years, mean age 74.7 years, 13 men). For the reperfusion catheter of the Penumbra system, the 5MAX ACE was used in 15 cases, and the 5MAX was used in 2 cases. As a compliant balloon catheter, the Scepter C was used in 16 cases, and the TransForm C was used in 1 case. The technique was successful in 16 cases (94.1%). No parent artery dissections were noted in any cases. Catheter-induced vasospasm was noted in 1 case, but the vasospasm was transient. CONCLUSIONS A coaxial system with a compliant balloon catheter can

  2. Optical coherence tomography monitoring of angioplasty balloon inflation in a deployment tester

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Bourezak, Rafik; Boulet, Benoit; Lamouche, Guy

    2010-08-01

    We present an innovative integration of an intravascular optical coherence tomography probe into a computerized balloon deployment system to monitor the balloon inflation process. The high-resolution intraluminal imaging of the balloon provides a detailed assessment of the balloon quality and, consequently, a technique to improve the balloon manufacturing process. A custom-built swept-source optical coherence tomography system is used for real-time imaging. A semicompliant balloon with a nominal diameter of 4 mm is fabricated for the experiments. Imaging results correspond to balloon deployment in air and inside an artery phantom. A characterization of the balloon diameter, wall thickness, compliance, and elastic modulus is provided, based on image segmentation. Using the images obtained from the probe pullback, a three-dimensional visualization of the inflated balloon is presented.

  3. Segmentally enclosed thrombolysis in percutaneous transluminal angioplasty for femoropopliteal occlusions

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Nielsen, J D;

    1991-01-01

    Segmentally enclosed thrombolysis (SET) was performed immediately following 34 percutaneous transluminal angioplasties (PTAs) for femoropopliteal occlusions. The dilated segment was sealed off with a double balloon catheter, and recombinant tissue plasminogen activator (rt-PA) 1 mg/ml and heparin...

  4. Balloon catheters for induction of labor at term after previous cesarean section: a systematic review.

    Science.gov (United States)

    Kehl, Sven; Weiss, Christel; Rath, Werner

    2016-09-01

    To systematically review the application of balloon catheters for cervical ripening and labor induction at term after previous cesarean section. All pregnancies at term with previous cesarean section were included when cervical ripening or labor induction was conducted with balloon catheters. MEDLINE, Cochrane database and bibliography of identified articles were searched for English language studies. Reviews and meta-analysis, randomized and non-randomized controlled trials, prospective and retrospective cohort studies as well as case-control studies were considered. A total of 48 potentially relevant studies were identified. The title and abstract were screened for eligibility and 32 articles were excluded. The remaining 16 publications included 1447 women (single-balloon catheter: n=1329, double-balloon catheter: n=118). There were no randomized controlled trials. Most of the trials were retrospective studies (n=10). The rate of uterine rupture after labor induction was low (n=18, 1.2%). Meta-analysis of studies comparing the risk of uterine rupture between labor induction and spontaneous onset of labor found a higher risk after induction (OR 2.45, 95%CI 1.34-4.47, NNH 186). The average rate of oxytocin application was 68.4%, and vaginal birth was achieved in 56.4%. The risk for cesarean delivery was higher when labor was induced (OR 2.63, 95%CI 2.24-3.10). Data on balloon catheters for labor induction after previous cesarean section are limited by small sample size and retrospective analyses. The present data show a moderately increased risk for uterine rupture (OR=2.45) compared to spontaneous onset of labor. However, for evidence based recommendations much more well-conducted trials are needed.

  5. Stability and Agreement of a Microtransducer and an Air-Filled Balloon Esophageal Catheter in the Monitoring of Esophageal Pressure.

    Science.gov (United States)

    Augusto, Renan Maloni; Albuquerque, André Luis Pereira; Jaeger, Thomas; de Carvalho, Carlos Roberto Ribeiro; Caruso, Pedro

    2017-02-01

    The use of esophageal catheters with microtransducer promises advantages over traditional catheters with air-filled balloons. However, performance comparisons between these 2 types of catheters are scarce and incomplete. A catheter with a 9.5-cm air-filled balloon at the distal tip and a catheter with a microtransducer mounted within a flexible silicone rubber were tested in vitro and in vivo. In vitro, the response times of both catheters were compared, and the drift of the baseline pressure of the microtransducer catheter was evaluated over a 6-h period. In vivo, 11 healthy volunteers had both catheters inserted, and the drift of the baseline esophageal pressure was measured over a 3-h period. Also, the correlation and agreement of the baseline and changes in the esophageal pressure of both catheters were evaluated. In vitro, the microtransducer catheter had a response time significantly higher (262 × 114 Hz, P pressure stability, with a mean baseline pressure drift of 1.4 cm H2O. In vivo, both catheters presented a small and similar baseline esophageal pressure drift (P = 0.08). For measurements of baseline and changes in esophageal pressure, the correlation and agreement between the catheters were poor, with a large bias between them. The catheter with the microtransducer had a small baseline pressure drift, similar to the air-filled balloon catheter. The low agreement between the catheters does not allow the microtransducer catheter to be used as a surrogate for the traditional air-filled balloon catheter. Copyright © 2017 by Daedalus Enterprises.

  6. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN).

    Science.gov (United States)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K

    2016-08-01

    To describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results. This is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture. Mean duration of catheter use was 278 days (range 32-503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported. The REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  7. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong [Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-06-15

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT.

  8. Lumen narrowing after percutaneous transluminal coronary balloon angioplasty follows a near gaussian distribution: a quantitative angiographic study in 1,445 successfully dilated lesions

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); P.J. de Feyter (Pim); J.G.P. Tijssen (Jan); P.W.J.C. Serruys (Patrick); J.W. Deckers (Jaap)

    1992-01-01

    textabstractTo determine whether significant angiographic narrowing and restenosis after successful coronary balloon angioplasty is a specific disease entity occurring in a subset of dilated lesions or whether it is the tail end of a gaussian distributed phenomenon, 1,445 successfully dilated lesion

  9. Continued benefit of coronary stenting versus balloon angioplasty: one-year clinical follow-up of Benestent trial. Benestent Study Group.

    NARCIS (Netherlands)

    C.M. Miguel (Carlos); P.W.J.C. Serruys (Patrick); P.N. Ruygrok (Peter); H. Suryapranata (Harry); S. Klugmann (Silvio); P. Urban (Philip); P. den Heijer (Peter); K. Koch (Karel); R. Simon (Rudiger); M-C. Morice (Marie-Claude); P.A. Crean (Peter); J.J.R.M. Bonnier (Hans); W. Wijns (William); N. Danchin (Nicolas); C. Bourdonnec (Claude); M-A.M. Morel (Marie-Angèle); E.G. Mast (Gijs)

    1996-01-01

    textabstractObjectives. This study sought to determine the 1-year clinical follow-up of patients included in the Benestent trial. Background. The Benestent trial is a randomized study comparing elective Palmaz-Schatz stent implantation with balloon angioplasty in patients with stable angina and a de

  10. Cutting balloon angioplasty for in-stent restenosis of the aortic coarctation in a young boy presenting with systemic hypertension of the upper extremities.

    Science.gov (United States)

    Lee, Meng-Luen

    2013-12-01

    An 8.25-year-old boy was incidentally found to have systemic hypertension of the upper extremities. Blood pressures of the upper extremities were 142-150/86-98 mmHg, and those of the lower extremities 110-116/60-66 mmHg. Doppler echocardiography showed in-stent restenosis of the aortic coarctation. Traditional high-pressure balloon angioplasty failed to dilate this inveterate in-stent restenosis. Instead, a cutting balloon angioplasty was performed. The lumen was dilated from 4.80 mm to 7.89 mm. The pressure gradient dropped from 32 mmHg to 9 mmHg. Blood pressures of the upper extremities were 112-116/76-78 mmHg, and those of the lower extremities 100-104/70-72 mmHg. This paper highlights that a cutting balloon angioplasty can serve as a juste milieu to relieve in-stent restenosis of the aortic coarctation when traditional high-pressure balloon angioplasty is debatable.

  11. Clinical impact and risk stratification of balloon angioplasty for femoropopliteal disease in nitinol stenting era: Retrospective multicenter study using propensity score matching analysis

    Directory of Open Access Journals (Sweden)

    Taketsugu Tsuchiya

    2016-07-01

    Full Text Available Objective: Nitinol stenting could bring the better outcome in endovascular therapy for femoropopliteal disease. However, it might be expected that recent marked advances in both device technology and operator technique had led to improved efficacy of balloon angioplasty even in this segment. The aims of this study were to evaluate the clinical impact of balloon angioplasty for femoropopliteal disease and make risk stratification clear by propensity score matching analysis. Methods: Based on the multicenter retrospective data, 2758 patients (balloon angioplasty: 729 patients and nitinol stenting: 2029 patients, those who underwent endovascular therapy for femoropopliteal disease, were analyzed. Results: The propensity score matching procedure extracted a total of 572 cases per group, and the primary patency rate of balloon angioplasty and nitinol stenting groups after matching was significantly the same (77.2% vs 82.7% at 1 year; 62.2% vs 64.3% at 3 years; 47.8% vs 54.3% at 5 years. In multivariate Cox hazard regression analysis, significant predictors for primary patency were diabetes mellitus, regular dialysis, cilostazol use, chronic total occlusion, and intra-vascular ultra-sonography use. The strategy of balloon angioplasty was not evaluated as a significant predictor for the primary patency. After risk stratification using five items (diabetes mellitus, regular dialysis, no use of intra-vascular ultra-sonography, chronic total occlusion, and no use of cilostazol: the DDICC score, the estimated primary patency rates of each group (low, DDICC score 0–2; moderate, DDICC score 3; high risk, DDICC score 4–5 were 88.6%, 78.3%, and 63.5% at 1 year; 75.2%, 60.7%, and 39.8% at 3 years; and 66.0%, 47.1%, and 26.3% at 5 years (p < 0.0001. The primary patency rate of balloon angioplasty and nitinol stenting groups was significantly the same in each risk stratification. Conclusion: This study suggests that balloon angioplasty does

  12. A system for visualization and automatic placement of the endoclamp balloon catheter

    Science.gov (United States)

    Furtado, Hugo; Stüdeli, Thomas; Sette, Mauro; Samset, Eigil; Gersak, Borut

    2010-02-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and kept in place within the aorta. The presented system addresses the two biggest difficulties of the task: lack of visualization and difficulty in maneuvering the catheter. The system was developed using a user centered design methodology with medical doctors, engineers and human factor specialists equally involved in all the development steps. The system was implemented using the AR framework "Studierstube" developed at TU Graz and can be used to visualize in real-time the position of the balloon catheter inside the aorta. The spatial position of the catheter is measured by a magnetic tracking system and superimposed on a 3D model of the patient's thorax. The alignment is made with a rigid registration algorithm. Together with a user defined target, the spatial position data drives an actuator which adjusts the position of the catheter in the initial placement and corrects migrations during the surgery. Two user studies with a silicon phantom show promising results regarding usefulness of the system: the users perform the placement tasks faster and more accurately than with the current restricted visual support. Animal studies also provided a first indication that the system brings additional value in the real clinical setting. This work represents a major step towards safer and simpler minimally invasive cardiac surgery.

  13. Long-term outcome after balloon angioplasty of coarctation of the aorta in adolescents and adults: Is aneurysm formation an issue?

    Science.gov (United States)

    Walhout, R J; Suttorp, M J; Mackaij, G J; Ernst, J M P G; Plokker, H W M

    2009-03-01

    The purpose was to evaluate long-term outcome following balloon angioplasty for coarctation in adults. Long-term results of balloon angioplasty for native coarctation in adults remain incomplete, especially concerning the occurrence of aneurysm formation. Long-term follow-up data were collected in consecutive patients retrospectively. Results of balloon angioplasty (29 patients, age 15-71 years, during 1995-2005) for discrete, native coarctation were evaluated, including MRI or CT. Mean follow-up ranged from 2.2 to 13 years (mean 8.5 +/- 3.2). Immediate success was obtained in all patients. Early mortality or complications were not encountered. Peak systolic pressure gradient decreased from 52 +/- 21 to 7.2 +/- 7.6 mm Hg (P < 0.001). Intima tear was detected in eight procedures angiographically, without signs of dissection. Three-month follow-up angiography in these patients showed unchanged (4/8 patients) or diminished abnormalities (4/8 patients). One asymptomatic patient, known with left ventricular dysfunction due to significant aortic valve insufficiency, died suddenly 5 years after balloon angioplasty. Recoarctation occurred in one patient (3%). Late aneurysm formation was excluded by MR in 24/29 and CT in remaining 5/29 patients during follow-up, including those patients in whom intima tear was encountered immediately postangioplasty. In three of seven patients an irregular aortic contour persisted, without indication of progression or aneurysm formation. Hypertension was completely relieved in 67% (14/21 patients) and improved in 33% (7/21 patients). Balloon angioplasty for native coarctation yields low reintervention probability in adult patients. Despite occurrence of angiographically established intimal tearing, aortic dissection and aneurysm formation were not encountered. (c) 2009 Wiley-Liss, Inc.

  14. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients: Results with Use of a High Sensitivity Polymerase Chain Reaction Assay.

    Science.gov (United States)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik; Holmstrup, Palle; Helqvist, Steffen; Tolker-Nielsen, Tim; Givskov, Michael; Hansen, Peter Riis

    2015-01-01

    Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors, and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction and purification steps, and demonstration of sensitivity levels of 25-125 colony forming units (CFU), we did not detect bacterial DNA from any of the coronary angioplasty balloons. A subsequent questionnaire indicated that the prevalence of periodontitis in the study cohort was at least 39.5%. Although coronary angioplasty balloons are unlikely to be useful for detection of bacteria with current PCR techniques in unselected patients with coronary artery disease, more studies are warranted to determine the extent to which bacteria contribute to atherosclerosis and its clinical manifestations and whether the presence of bacteria in the arteries is a transient phenomenon.

  15. Radiation recall secondary to adjuvant docetaxel after balloon-catheter based accelerated partial breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Nathan W. [Summer Intern, Mayo Clinic Arizona, Scottsdale, AZ (United States); Wong, William W., E-mail: wong.william@mayo.ed [Department of Radiation Oncology, Mayo Clinic Arizona, 13400 E. Shea Boulevard, Scottsdale, AZ 85259 (United States); Karlin, Nina J. [Division of Oncology, Mayo Clinic Arizona, Scottsdale, AZ (United States); Gray, Richard J. [Department of Surgery, Mayo Clinic Arizona, Scottsdale, AZ (United States)

    2010-08-15

    For early stage breast cancer, wide local excision and post-operative whole breast irradiation is a standard treatment. If adjuvant chemotherapy is recommended, radiation is usually given after completion of chemotherapy. In recent years, accelerated partial breast irradiation (APBI) with balloon-cathetered based brachytherapy has become an option for selected patients. For these patients, adjuvant chemotherapy would have to be administered after radiation. The sequence of treatment with radiation followed by chemotherapy results in increased risk of radiation recall reaction (RRD) in these patients. Docetaxel is becoming a more commonly used drug as adjuvant treatment for breast cancer. Here we report a case of docetaxel induced RRD after APBI with balloon-cathetered based brachytherapy. Such reaction would have an adverse impact on the cosmetic outcome and quality of life of the patient. For patients who develop an intense skin reaction after the administration of docetaxel following APBI, RRD should be considered in the differential diagnosis.

  16. Evaluating condom catheter balloon tamponade in non-traumatic postpartum haemorrhage resistant to medical management

    Directory of Open Access Journals (Sweden)

    Syed Nawaz Ahmad

    2016-06-01

    Conclusions: Placement of a condom catheter balloon can successfully treat non-traumatic PPH refractory to medical management. It is simple, inexpensive, easily, available and in those with successful placement no procedure related morbidity was observed. The potential for it to be used by inexperienced operators in areas with limited resources makes it a useful tool in management of PPH. [Int J Reprod Contracept Obstet Gynecol 2016; 5(6.000: 1874-1878

  17. Arterioureteral Fistula: Treatment of a Hemorrhagic Shock with Massive Hematuria by Placing a Balloon Catheter

    Directory of Open Access Journals (Sweden)

    Nicolas Merzeau

    2017-01-01

    Full Text Available Arterioureteral fistulas (AUF are serious diseases with increasing incidence. This case report relates the management of AUF in a patient with a history of abdominal oncological surgery, pelvic radiotherapy, and a double J stent in place. The fistula was discovered during a hemorrhagic shock with massive hematuria. The bleeding was controlled by a balloon catheter which led to endovascular treatment consisting of a covered stent.

  18. Simulation of balloon angioplasty in residually stressed blood vessels-Application of a gradient-enhanced fibre damage model.

    Science.gov (United States)

    Polindara, César; Waffenschmidt, Tobias; Menzel, Andreas

    2016-08-16

    In this contribution we study the balloon angioplasty in a residually stressed artery by means of a non-local gradient-enhanced fibre damage model. The balloon angioplasty is a common surgical intervention used to extend or reopen narrowed blood vessels in order to restore the continuous blood flow in, for instance, atherosclerotic arteries. Inelastic, i.e. predominantly damage-related and elastoplastic processes are induced in the artery during its inflation resulting in an irreversible deformation. As a beneficial consequence, provided that the inelastic deformations do not exceed a specific limit, higher deformations can be obtained within the same pressure level and a continuous blood flow can be guaranteed. In order to study the mechanical response of the artery in this scenario, we make use of the non-local gradient-enhanced model proposed in Waffenschmidt et al. (2014). In this contribution, we extend this model to make use of an incompressible format in connection with a Q1Q1P0 finite element implementation. The residual stresses in the artery are also taken into account following the framework presented in Waffenschmidt (2015). From the results it becomes apparent that, when the artery is subjected to radial stresses beyond the physiological range, damage evolution is triggered in the collagen fibres. The impact of the residual stresses on the structural response and on the circumferential stress distribution along the thickness of the arterial wall is also studied. It is observed that the residual stresses have a beneficial effect on the mechanical response of the arterial wall.

  19. Ultrasonography-guided Balloon Angioplasty in an Autogenous Arteriovenous Fistula: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Chang [Daejeon St Mary' s Hospital, Daejeon (Korea, Republic of); Cho, June Sik [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2007-09-15

    Percutaneous trasnluminal angioplasty (PTA) of a malfunctioning arteriovenous fistula (AVF) in hemodialysis patients requires the use of contrast angiography and fluoroscopy guidance. We attempted to perform this procedure under duplex ultrasound guidance to reduce the amount of contrast agent administered and to reduce the radiation dose during the interventional procedures. From September 2006 to February 2007, 45 patients received interventional treatment due to malfunctioning hemodialysis access in our hospital. Among the patients, we selected 10 patients diagnosed with stenosis of an autogenous arteriovenous fistula based on a physical examination. There were six males and four females aged 51-78 years (mean age, 59 years). Seven of these patients had a Brescia-Cinimo type fistula and three patients had a basilic vein transposition. All procedures were performed in the angiography suite. All procedures that required angioplasty were performed under duplex ultrasound guidance and then contrast angiography was performed to confirm the final patency of the vessels. Conventional angioplasty was also performed under fluoroscopy guidance for any lesions that required an additional angioplasty. The volume flow before and after the PTA and procedure time were recorded. Clinical success was defined as the performance of one or more successful hemodialysis sessions after treatment. Eight of ten patients did not require an additional angioplasty by conventional angiography after the duplex- guided angioplasty. One case showed recoiling of stenosis after the duplex-guided PTA and another case was missed at duplex scanning due to the extremely short nature of the recoiling of stenosis. The mean volume flow before and after PTA was 167 ml/min (range, 80-259 ml/min) and 394.2 ml/min (range, 120-586 ml/min), respectively. No complications associated with the duplex-guide procedure occurred. In nine cases, PTA enabled hemodialysis to be conducted more than one time. In one

  20. Percutaneous Balloon Angioplasty for Severe Native Aortic Coarctation in Young Infants Less Than 6 Months: Medium-to Long-term Follow-up

    Institute of Scientific and Technical Information of China (English)

    Lan He; Fang Liu; Lin Wu; Chun-Hua Qi; Li-Feng Zhang; Guo-Ying Huang

    2015-01-01

    Background:Although balloon angioplasty (BA) has been performed for more than 20 years,its use as a treatment for native coarctation of the aorta (CoA) during childhood,especially in young infants,remains controversial.This study aimed to assess the effects and potential role of percutaneous transcatheter BA for native CoA as an alternative therapy to surgical repair in young infants.Methods:The 37 patients aged from 6 days to 6 months with severe CoA in congestive heart failure or circulatory shock were admitted for BA.Patient's weight ranged from 2.4 to 6.1 kg.All 37 patients were experiencing cardiac dysfunction,and eight patients were in cardiac shock with severe metabolic acidosis.Eleven patients had an isolated CoA,whereas the others had a CoA associated with other cardiac malformations.Cardiac catheterization and aortic angiography were performed under general anesthesia with intubation.Transfemoral arterial approaches were used for the BA.The size of the balloon ranged from 3 mm × 20 mm to 8 mm × 20 mm,and a coronary artery balloon catheter was preferred over a regular peripheral vascular balloon catheter.Results:The femoral artery was successfully punctured in all but one patient,with that patient undergoing a carotid artery puncture.The systolic peak pressure gradient (PG) across the coarctation was 41.0 ± 16.0 mmHg (range 13-76 mmHg).The mean diameter of the narrowest coarctation site was 1.7 ± 0.6 mm (range 0.5-2.8 mm).All patients had successful dilation;the PG significantly decreased to 13.0 ± 1 1.0 mmHg (range 0-40 mmHg),and the diameter of coarctation significantly improved to 3.8 ± 0.9 mm (range 2.5-5.3 mm).No intraoperative complications occurred for any patients.However,in one case that underwent a carotid artery puncture,a giant aneurysm formed at the puncture site and required surgical repair.The following observations were made during the follow-up period from 6-month to 7-year:(1) The PG across the coarctation measured by

  1. High prevalence of severe coronary artery disease in elderly patients with non-operable chronic thromboembolic pulmonary hypertension referred for balloon pulmonary angioplasty

    Directory of Open Access Journals (Sweden)

    Marek Roik

    2016-11-01

    Full Text Available Introduction : Balloon pulmonary angioplasty (BPA is a new emerging catheter-based alternative treatment option for patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH. Aim : To show that all elderly CTEPH patients referred for BPA are at higher risk of obstructive coronary artery disease and that, in daily practice, they should undergo invasive coronary angiography. Material and methods : Eleven patients at the age of at least 65 years (6 males, 5 females, 77.2 ±5.9 years with confirmed non-operable type II or type III CTEPH, considered for BPA, underwent elective coronary angiography. Severe obstructive coronary artery disease (CAD was diagnosed when stenosis of left main coronary artery ≥ 50% or stenosis of ≥ 70% of epicardial arteries was angiographically confirmed. We also screened for CAD consecutive age- and sex-matched 114 PE survivors (52 males, 62 females, 74.8 ±7.2 years with excluded CTEPH. Results : Severe CAD was more frequent in elderly patients with non-operable type II or type III CTEPH candidates for BPA than in elderly acute PE survivors with excluded CTEPH (54.5% vs. 16.7%, p < 0.01, and therefore elderly CTEPH patients referred for BPA were at higher risk of CAD (OR = 5.9, 95% CI: 1.64–21.46, p = 0.007 when compared to elderly survivors after acute PE with excluded CTEPH. Conclusions : All elderly CTEPH patients referred for BPA are at higher risk of severe CAD and should routinely undergo invasive coronary angiography before BPA.

  2. A Simple Radiological Technique for Demonstration of Incorrect Positioning of a Foley Catheter with Balloon Inflated in the Urethra of a Male Spinal Cord Injury Patient

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2006-01-01

    Full Text Available In a male patient with cervical spinal cord injury, the urinary bladder may go into spasm when a urethral catheter is removed and a new Foley catheter is inserted. Before the balloon is inflated, the spastic bladder may push the Foley catheter out or the catheter may slip out of a small-capacity bladder. An inexperienced health professional may inflate the balloon of a Foley catheter in the urethra without realizing that the balloon segment of the catheter is lying in the urethra instead of the urinary bladder. When a Foley balloon is inflated in the urethra, a tetraplegic patient is likely to develop autonomic dysreflexia. This is a medical emergency and requires urgent treatment. Before the incorrectly placed Foley catheter is removed, it is important to document whether the balloon has been inflated in the urinary bladder or not. The clinician should first use the always available tools of observation and palpation at the bedside without delays of transportation. A misplaced balloon will often be evident by a long catheter sign, indicating excessive catheter remaining outside the patient. Radiological diagnosis is not frequently required and, when needed, should employ the technique most readily available, which might be a body and pelvic CT without intravenous contrast. An alternative radiological technique to demonstrate the position of the balloon of the Foley catheter is described. Three milliliters of nonionic X-ray contrast medium, Ioversol (OPTIRAY 300, is injected through the side channel of the Foley catheter, which is used for inflating the balloon. Then, with a catheter-tip syringe, 30 ml of sterile Ioversol is injected through the main lumen of the Foley catheter. Immediately thereafter, an X-ray of the pelvis (including perineum is taken. By this technique, both the urinary bladder and balloon of the Foley catheter are visualized by the X-ray contrast medium. When a Foley catheter has been inserted correctly, the balloon of the

  3. Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter.

    Science.gov (United States)

    Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Liang, Kaicheng; Wang, Zhao; Cleveland, Cody; Booth, Lucas; Potsaid, Benjamin; Jayaraman, Vijaysekhar; Cable, Alex E; Mashimo, Hiroshi; Langer, Robert; Traverso, Giovanni; Fujimoto, James G

    2016-08-01

    We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm(2) area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated.

  4. Percutaneous transluminal angioplasty and stenting of the vertebral artery ostium with balloon-mounted bare coronary stents

    Directory of Open Access Journals (Sweden)

    Javad Kojuri

    2011-01-01

    Full Text Available Background : Vertebral artery ostial stenosis (VAOS is one of the most frequent causes of posterior circulation stroke. Percutaneous angioplasty and stenting (PTAS is one of the treatment modalities. Patients and Methods : This is a longitudinal observational study from September 2006 to February 2009, conducted at hospitals affiliated with the Shiraz University of Medical Sciences, Shiraz, southern Iran. The patient cohort included patients with posterior circulation stroke or transient ischemic attack (TIA and more than 70% VAOS, and patients with asymptomatic VAOS of more than 70% and aplasia or total occlusion of the contralateral VA or subclavian artery. All the patients underwent PTAS with balloon-mounted bare coronary stents. Technical success, procedural complications, composite outcomes of death, stroke or TIA in the vertebrobasilar territory during the first 30 days, stroke or TIA in the vertebrobasilar territory, and restenosis during follow-up, were assessed. Results : During the study period, 81 patients (mean age 68 + 8.9 years, 63 (78% males, 71 symptomatic and 18 asymptomatic underwent the procedure. Technical success was achieved in 88 (99% patients. Procedure-related complications, other than puncture site complications, were seen in two patients (2.2%. The composite outcome of death, stroke or TIA in the vertebrobasilar territory during the first 30 days was 1%. None of the patients had clinical recurrence or restenosis during the follow-up (mean follow-up 14 months. Conclusion : Percutaneous transluminal angioplasty and stenting of the proximal VA was feasible and safe. The risk of restenosis should be analyzed in long-term studies with angiographic follow-up.

  5. Cephalic arch stenosis in autogenous brachiocephalic hemodialysis fistulas: results of cutting balloon angioplasty

    DEFF Research Database (Denmark)

    Heerwagen, Søren Thorup; Lönn, Lars; Schroeder, Torben V;

    2010-01-01

    Cephalic arch stenosis is a known cause of hemodialysis access failure in patients with brachiocephalic fistulas (BCFs). Outcomes of endovascular treatment are affected by resistance of the stenosis to balloon dilation, a high vein rupture rate and the development of early restenosis. The purpose...

  6. Femoral artery recanalisation with percutaneous angioplasty and segmentally enclosed plasminogen activator

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Bülow, J;

    1989-01-01

    To establish whether re-occlusion of the femoral artery could be prevented, in 6 consecutive patients undergoing percutaneous transluminal angioplasty (PTA) for superficial femoral artery occlusion the recanalised segment was isolated, with a 7-French double-balloon catheter. 5 mg recombined human...

  7. Longitudinal stent elongation during retraction of entrapped jailed guidewire in a side branch with balloon catheter support: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Norimasa; Mizuguchi, Yukio; Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp

    2015-01-15

    A 72-year-old man underwent primary percutaneous coronary intervention for a subtotal occlusion in the mid-portion of the left anterior descending artery involving a large diagonal branch. After successful stenting with a 3.0/24 mm bare metal stent, during which, the diagonal branch was protected with a coronary guidewire, conventional retrieval of the jailed guide wire was impossible. Subsequently, several attempts at a strong retraction of the wire with the support of a balloon catheter enabled retrieval of the trapped wire. Optical coherence tomography performed after post-dilatation, revealed that the stent was elongated to the left main coronary artery, and the structure of the strut had become coarse in the proximal portion. The stent was believed to have become entangled with the balloon catheter when the guidewire was being pulled. This case suggests that retrieving the jailed guidewire with a balloon catheter carries a potential risk of entrapment in the deformed stent.

  8. Measurement of luminal nitric oxide in the uterine cavity using a silicon balloon catheter.

    Science.gov (United States)

    Sioutas, Angelos; Gemzell-Danielsson, Kristina; Lundberg, Jon O; Ehrén, Ingrid

    2011-05-31

    The aim of this pilot case-control study was to measure nitric oxide (NO) gas in air incubated in a catheter balloon in the uterus of healthy women and patients with pelvic inflammatory disease, to determine the optimal time of incubation and to find whether NO level rises after manipulation in the uterine cavity. We measured nitric oxide levels in air incubated for 2-10 min in a catheter balloon in the uterine cavity in 6 non pregnant women from 22 to 50 years of age with lower abdominal pain and 10 healthy women with regular menstrual cycles. After an incubation time of just 2 min, intrauterine nitric oxide levels were significantly increased in patients with diagnosed pelvic inflammatory disease compared to healthy women. Uterine nitric oxide levels did not rise after manipulation in the uterine cavity. In conclusion, NO gas can be measured directly in the uterine cavity with a fast, simple, well-tolerated and safe method. The levels of nitric oxide are increased in women diagnosed with pelvic inflammatory disease already after an incubation time of 2 min.

  9. Micro catheter Balloon Pinning technique to facilitate wiring of a left circumflex CTO.

    Science.gov (United States)

    Oguayo, Kevin N; Oguayo, Chris C; Vallabhan, Ravi; Choi, James W

    2017-07-27

    Coronary chronic total occlusions (CTOs) are commonly encountered during diagnostic angiograms. With recent advances, especially in experienced centers, success rates with CTO percutaneous coronary intervention (PCI) have approached 80% or higher. It is important to note that despite these advancements in techniques, CTOs remain difficult to treat. We present a case of a left circumflex artery (LCX) CTO that was successfully revascularized using a microcatheter balloon pinning technique that allowed additional wire support. A 77-year-old woman status post 2 vessel coronary artery bypass graft surgery presented with new onset angina at rest and was found to have a patent graft to the left anterior descending artery, and an unrevascularized proximal LCX CTO. PCI was attempted with a micro catheter using an antegrade approach. This approach was unsuccessful due to the lack of support and the left circumflex angle. As a result, we used a balloon to pin the microcatheter to the wall of the left main to allow for successful wiring of the LCX. A stent was successfully deployed in the LCX. and the patient was discharged from the hospital two days later. At follow-up, the patient was asymptomatic and returned to her usual activity. After conducting a thorough literature search, it appears that this is the first case that a microcatheter has been pinned with a balloon. We believe that in LCX CTOs that require support, the microcatheter pinning technique can provide adequate support in wiring CTO's. LCX CTOs can be very difficult to treat, we present a case of a LCX CTO that required the use of the microcatheter balloon pinning technique to allow additional wire support for successful wiring and ultimately treatment. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Restoration of patency in failing tunneled hemodialysis catheters: a comparison of catheter exchange, exchange and balloon disruption of the fibrin sheath, and femoral stripping.

    Science.gov (United States)

    Janne d'Othée, Bertrand; Tham, Jacques C; Sheiman, Robert G

    2006-06-01

    To compare median patency times after treatment of malfunctioning tunneled hemodialysis catheters by one of three techniques: over-the-wire catheter exchange (CE), fibrin sheath stripping (FSS) from a femoral vein approach, and over-the-wire catheter removal with balloon dilation of fibrin sheath (DFS) followed by catheter replacement with use of the same tract. Retrospective study was conducted of 66 consecutive procedures performed over a period of 47 months for poor flow through tunneled hemodialysis catheters despite tissue plasminogen activator infusion trials (CE, n=33; FSS, n=18; DFS, n=15). Baseline parameters (time since initial catheter placement, number of previous catheter interventions, catheter access site, and patient age and sex) were recorded to identify possible pretreatment differences among groups. Outcome comparison was based on duration of adequate catheter function on dialysis during follow-up. No significant differences in baseline parameters were identified among the three groups (P>.05). Mean follow-up duration (67+/-89 days; range, 0-398 d) was similar among the three groups. The immediate technical success rate was 100%, and there were no complications. Cumulative catheter patency rates were 73% (CE), 72% (FSS), and 65% (DFS) at 1 month; 43% (CE), 60% (FSS), and 39% (DFS) at 3 months; and 28% (CE), 45% (FSS), and 39% (DFS) at 6 months. Median duration of patency was similar among groups (P=.60). All three therapies were equivalent in terms of immediate technical success, complication rates, and durability of catheter function during later follow-up. Hence, when one technique is chosen over another, factors other than the period of secondary patency should be considered, such as cost and patient and physician preference.

  11. Utility of birefringence changes due to collagen thermal denaturation rate process analysis: vessel wall temperature estimation for new short term heating balloon angioplasty

    Science.gov (United States)

    Kaneko, Kenji; Shimazaki, Natsumi; Gotoh, Maya; Nakatani, Eriko; Arai, Tsunenori

    2007-02-01

    Our photo thermal reaction heating architecture balloon realizes less than 10 s short term heating that can soften vessel wall collagen without damaging surrounding tissue thermally. New thermal balloon angioplasty, photo-thermo dynamic balloon angioplasty (PTDBA) has experimentally shown sufficient opening with 2 atm low pressure dilation and prevention of chronic phase restenosis and acute phase thrombus in vivo. Even though PTDBA has high therapeutic potential, the most efficient heating condition is still under study, because relationship of treatment and thermal dose to vessel wall is not clarified yet. To study and set the most efficient heating condition, we have been working on establishment of temperature history estimation method from our previous experimental results. Heating target of PTDBA, collagen, thermally denatures following rate process. Denaturation is able to be quantified with measured collagen birefringence value. To express the denaturation with equation of rate process, the following ex vivo experiments were performed. Porcine extracted carotid artery was soaked in two different temperature saline baths to enforce constant temperature heating. Higher temperature bath was set to 40 to 80 degree Celsius and soaking duration was 5 to 40 s. Samples were observed by a polarizing microscope and a scanning electron microscope. The birefringence was measured by polarizing microscopic system using Brace-Koehler compensator 1/30 wavelength. The measured birefringence showed temperature dependency and quite fit with the rate process equation. We think vessel wall temperature is able to be estimated using the birefringence changes due to thermal denaturation.

  12. Tracheal rupture after intubation and placement of an endotracheal balloon catheter (A-view®) in cardiac surgery.

    Science.gov (United States)

    Timman, Simone T; Mourisse, Jo M; van der Heide, Stefan M; Verhagen, Ad F

    2016-09-01

    The endotracheal balloon catheter (A-view®) is a device developed to locate atherosclerotic plaques of the ascending aorta (AA) in cardiac surgery to prevent stroke. The saline-filled balloon is located in the trachea and combines the advantages of transoesophageal echocardiography (e.g. used before performing the sternotomy) and intraoperative epiaortic ultrasound scanning (e.g. complete view of the AA). We report the first severe complication after the use of A-view®. This is a case of a 66-year old woman who underwent elective myocardial revascularization complicated by an intraoperative iatrogenic tracheal rupture of 6 cm, after uncomplicated intubation and the use of an endotracheal balloon catheter (A-view®), which required direct surgical repair with a posterolateral thoracotomy after the myocardial revascularization was completed, weaning from bypass and closure of the median sternotomy.

  13. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  14. Voice prosthesis insertion after endoscopic balloon-catheter dilatation in case of a stenotic hypopharyngo-oesophageal junction.

    Science.gov (United States)

    Móricz, Péter; Gerlinger, Imre; Solt, Jeno; Somogyvári, Krisztina; Pytel, József

    2007-12-01

    Stenosis of the hypopharyngo-oesophageal junction can be a rare complication of laryngectomy and/or partial pharyngectomy and makes the insertion of voice prosthesis extremely difficult. This study describes the authors' experiences gained by endoscopic balloon-catheter dilatation of hypopharyngo-oesophageal stenoses prior to implantation of voice prostheses in four cases. In two patients a single balloon-catheter dilatation resulted in wide enough pharyngo-oesophageal lumen on the long run. The average prosthesis wearing-times were 6.8 months in case 1 and 4.6 months in case 2, corresponding to the published literature data. In case 3, repeated dilatation of the pharyngo-oesophageal transition had proved to be unsuccessful despite taking every effort with the endoscopic balloon-catheter method. Having excised the stenotic segment, reconstruction with pectoralis major myocutaneous flap (PMMF) was indicated. Eighteen months later, a repeated restenosis was observed and a free jejunal flap needed to be performed as a final solution. In case 4, the insertion was carried out into a previously dilated jejunal free flap, which became gradually ischemic and stenotic since the major head-and neck procedure was carried out that resulted in prosthesis rejection after just 1 week. The authors emphasize that correct indication of pedicled and free flaps in head and neck reconstruction is a prerequisite from the aspect of prevention of pharyngo-oesophageal strictures. Endoscopic balloon-catheter dilatation is a safe and established method for dilatating hypopharyngo-oesophageal stenoses of different origin. The procedure provides maximum patient benefit with minimal trauma and morbidity; moreover, facilitates insertion of voice prostheses. However, a single balloon-catheter dilatation cannot always result in wide enough oesophageal lumen on the long run (case 3). Insertion of a voice prosthesis into a previously dilated ischemic jejunal segment is challenging and avoidable due

  15. [Treatment of carotid-cavernous fistula using a detachable balloon catheter--a case report and review].

    Science.gov (United States)

    Chono, Y; Abe, H; Sasaki, H; Abe, S; Takei, H; Koiwa, M; Saito, H

    1983-01-01

    A case of post-traumatic carotid cavernous fistula, successfully treated by a detachable balloon catheter, is reported. A 55-year-old housewife was admitted to the author's department on 25th August, 1980. Three months prior to admission, she complained of right tinnitus following a traffic accident and then developed right chemosis and exophthalmus. A selective right internal carotid angiography revealed rapid filling of the carotid cavernous fistula. Under general anesthesia, the patient was treated by the maneuver after Debrun. Since it appeared necessary to employ the second balloon, the first one was released gently being inflated only with the contrast medium. During the procedure, the neck of the balloon was incidentally snapped upward and, then, the fistula was eventually occluded preserving the carotid flow as was verified by a control angiography. The bruit was abolished immediately after the procedure and all ocular symptoms disappeared during the following a few weeks. A skull film showed a deflation of the balloon at 4 weeks postoperatively, but clinical and angiographic follow-up examinations at 9 months thereafter revealed no signs or symptoms of recurrence. This Debrun's procedure is being widely accepted for a carotid cavernous fistula as a relatively simpler, safer, and more effective one comparing with the conventional methods. Our experiment on dogs, however, indicated that rupture of the balloon is not always avoidable even with a smaller volume than its maximum capacity and some resistance was felt during introduction of the co-axial catheter. Thus, it appeared mandatory to improve and quality control the balloon and the catheter. In the case presented here, a follow-up angiography showed no recurrence of the fistula except for an asymptomatic pseud-aneurysmal pouch, even though the balloon was inflated only with the contrast medium and was deflated within 4 weeks. These findings suggest possibility of successful, and long-lasting outcome

  16. Stent graft versus balloon angioplasty for failing dialysis access grafts: a long-awaited advance in the treatment of permanent hemodialysis access.

    Science.gov (United States)

    Dolmatch, Bart L

    2010-01-01

    Arteriovenous grafts (AVGs) for hemodialysis have a high failure rate, often due to the development of stenosis at the graft-to-vein anastomosis. Angioplasty (PTA) has been used for over two decades to treat AVG stenosis, with good technical success but limited AVG patency. Results of a prospective multi-center randomized trial, comparing stent graft to PTA in AVGs, has demonstrated superior access circuit patency for the stent graft group. Recent publication of this clinical study brings us into an exciting new era of dialysis access management using covered stents to improve durability of catheter-based therapy.

  17. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    deMuinck, ED; denHeijer, P; vanDijk, RB; Crijns, HJGM; Hillige, HL; Lie, KI

    1996-01-01

    Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty (PTCA)-with an autoperfusion balloon or active system-facilitates prolonged balloon inflation. Prolonged inflations may tack up intimal dissections and improve the primary angioplasty result in complex lesions. Addit

  18. Application of GlycoProtein lib/Ⅲa antagonist(Integrilin) in peri-percutaneous transluminal catheter angioplasty and stent implantation in Chinese

    Institute of Scientific and Technical Information of China (English)

    王建安; 孙勇

    2002-01-01

    Objective: to report the application of GPⅡb/Ⅲa antagonist (Integrilin) in peri-opercuta-neous transluminal catheter angioplasty and stent implantation in Chinese. Method: Twenty-one patients who underwent percutaneous transluminal catheter angioplasty(PTCA) and stent implantation were included. After arterial puncture, integrilin was injected at dose of 180ug/kg, and then main-tained at 2μg/kg·min for 18 hours. Asprine, plavix(clopidogrel) and heparin were used at the same time. ACT, PT, KPTT and blood routine were routinely monitored. Results: All sheaths were drawn out 2 to 4 hours after the procedure.. There was no severe complication such as hematoma, acute and subacute thrombosis in coronary artery, or thrombocytopenia. ACT returned to less than 150 aeconds in 2 hours in 15 patients; in 4 hours in 6 patients. There was no significant difference between the preand post-procedure value of PT and platelet count. KPTT was significantly higher than pre-procedure value at 2 hours after the procedure . No recurrence of angina pectoris was observed in the first nine patients within one year follow-up, and no restenosis occurred in stents in the five patients who had coronary angiography one year later. Conclusion: Application of GPⅡb/Ⅲa receptor antagonist (Integrilin)in peri-parcutaneous transluminal catheter angioplasty and stent implantation in combination with aspirin and plavix could significantly reduce the dosage and duration of heparin with benefit of shortening the indwelling time of sheaths, but did not increase risk of bleeding or lead to thrombosis in stent.

  19. Application of GlycoProtein IIb/IIIa antagonist( Integrilin) in peri-percutaneous transluminal catheter angioplasty and stent implantation in Chinese

    Institute of Scientific and Technical Information of China (English)

    王建安; 孙勇

    2002-01-01

    Objective: to report the application of GPIIb/IIIa antagonist (Integrilin) in peri-percutaneous transluminal catheter angioplasty and stent implantation in Chinese. Method: Twenty-one patients who underwent percutaneous transluminal catheter angioplasty(PTCA) and stent implantation were included. After arterial puncture, integrilin was injected at dose of 180ug/kg, and then maintained at 2μg/kgmin for 18 hours. Asprine, plavix(clopidogrel) and heparin were used at the same time. ACT, PT, KPTT and blood routine were routinely monitored. Results: All sheaths were drawn out 2 to 4 hours after the procedure.. There was no severe complication such as hematoma, acute and subacute thrombosis in coronary artery, or thrombocytopenia. ACT returned to less than 150 seconds in 2 hours in 15 patients; in 4 hours in 6 patients. There was no significant difference between the pre- and post-procedure value of PT and platelet count. KPTT was significantly higher than pre-procedure value at 2 hours after the procedure .No recurrence of angina pectoris was observed in the first nine patients within one year follow-up, and no restenosis occurred in stents in the five patients who had coronary angiography one year later. Conclusion: Application of GPIIb/IIIa receptor antagonist (Integrilin) in peri-percutaneous transluminal catheter angioplasty and stent implantation in combination with aspirin and plavix could significantly reduce the dosage and duration of heparin with benefit of shortening the indwelling time of sheaths, but did not increase risk of bleeding or lead to thrombosis in stent.

  20. Has multivessel angioplasty displaced surgical revascularization?

    Science.gov (United States)

    King, S B; Ivanhoe, R J

    1990-01-01

    Over the years, PTCA has been proved a safe and effective therapy for single-vessel CAD. Given the record of favorable results for single-vessel angioplasty, the extension of angioplasty to multivessel CAD soon followed. The successful application of PTCA to multivessel disease has been facilitated by developments in balloon, guidewire, and guide catheter technology. Success rates have been satisfactory, and complications have remained acceptable. Furthermore, as an outgrowth of an understanding of the mechanism and effect of PTCA, guidelines have been developed to aid case selection. As emphasized earlier, these guidelines should weigh heavily in deciding whether to select PTCA as a treatment modality. Presently, in our opinion, PTCA has not yet completely displaced surgery for multivessel CAD. Surgical standby is required for safe PTCA, because emergency surgery can be lifesaving and limit myocardial infarction after failed angioplasty. It is doubtful that surgery will ever relinquish its position as the treatment of choice for left main coronary artery disease. Nor will elective surgery find wide application in single-vessel disease. Whether one mode of revascularization will emerge as the most efficacious for multivessel disease related to long-term survival, limitation of cardiac events, and cost will be addressed in the analysis of the ongoing randomized trials of surgery versus angioplasty. Andreas Gruentzig established that it was possible to work within the coronary artery in an alert and comfortable patient. Interventional cardiology has experienced rapid technologic growth. Many patients formerly treated with bypass surgery can be managed effectively with angioplasty. If effective bail-out methods for acute closure are proven effective and restenosis is limited to a small percentage of patients, angioplasty in some form will further displace CABG. Until those ultimate goals are achieved, the value of angioplasty compared with bypass surgery must rest

  1. Dissection of Extracranial Internal Carotid Artery Due to Balloon Guiding Catheter Resulting in Asymptomatic Internal Carotid Artery Occlusion

    Science.gov (United States)

    Akpinar, Suha; Yilmaz, Guliz

    2016-01-01

    Dissection of the internal carotid artery (ICA) is a rare condition that accounts for a significant proportion of ischemic strokes in young adults. Iatrogenic dissection as a complication of neurointerventional procedures is a traumatic dissection which has been reported relatively rare in the literature. In this report, a case of dissection of the ICA is reported that was caused by repetitive movement of the balloon guiding catheter during stent-assisted thrombectomy (SAT), resulting in occlusion of the ICA. PMID:27853491

  2. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  3. Randomized trial of Legflow® paclitaxel eluting balloon and stenting versus standard percutaneous transluminal angioplasty and stenting for the treatment of intermediate and long lesions of the superficial femoral artery (RAPID trial): Study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    A. Karimi; S.W. de Boer (Sanne W.); D.A.F. Van Den Heuvel; B. Fioole (Bram); D. Vroegindeweij (Dammis); J.M.M. Heyligers (Jan); P.N.M. Lohle (Paul N.M.); O.E. Elgersma (Otto E.); R.P.T. Nolthenius (Rudolf ); J.A. Vos (Jan Albert); J.-P.P.M. de Vries (Jean-Paul)

    2013-01-01

    textabstractBackground: Restenosis after percutaneous transluminal angioplasty (PTA) of the superficial femoral artery (SFA) may occur in 45% of patients at 2 years follow-up. Paclitaxel-coated balloons have been found to reduce neointimal hyperplasia, and thus reduce restenosis. Recently, the Legfl

  4. Diffusing, side-firing, and radial delivery laser balloon catheters for creating subsurface thermal lesions in tissue

    Science.gov (United States)

    Chang, Chun-Hung; Fried, Nathaniel M.

    2016-02-01

    Infrared lasers have been used in combination with applied cooling methods to preserve superficial skin layers during cosmetic surgery. Similarly, combined laser irradiation and tissue cooling may also allow development of minimally invasive laser therapies beyond dermatology. This study compares diffusing, side-firing, and radial delivery laser balloon catheter designs for creation of subsurface lesions in tissue, ex vivo, using a near-IR laser and applied contact cooling. An Ytterbium fiber laser with 1075 nm wavelength delivered energy through custom built 18 Fr (6-mm-OD) balloon catheters incorporating either 10-mm-long diffusing fiber tip, 90 degree side-firing fiber, or radial delivery cone mirror, through a central lumen. A chilled solution was flowed through a separate lumen into 9-mm-diameter balloon to keep probe cooled at 7°C. Porcine liver tissue samples were used as preliminary tissue model for immediate observation of thermal lesion creation. The diffusing fiber produced subsurface thermal lesions measuring 49.3 +/- 10.0 mm2 and preserved 0.8 +/- 0.1 mm of surface tissue. The side-firing fiber produced subsurface thermal lesions of 2.4 +/- 0.9 mm2 diameter and preserved 0.5 +/- 0.1 mm of surface tissue. The radial delivery probe assembly failed to produce subsurface thermal lesions, presumably due to the small effective spot diameter at the tissue surface, which limited optical penetration depth. Optimal laser power and irradiation time measured 15 W and 100 s for diffusing fiber and 1.4 W and 20 s, for side-firing fiber, respectively. Diffusing and side-firing laser balloon catheter designs provided subsurface thermal lesions in tissue. However, the divergent laser beam in both designs limited the ability to preserve a thicker layer of tissue surface. Further optimization of laser and cooling parameters may be necessary to preserve thicker surface tissue layers.

  5. 切割球囊扩张在股浅动脉长段闭塞治疗中的作用%Angioplasty with cutting balloon in patient with long segmental obstruction of superficial femoral artery

    Institute of Scientific and Technical Information of China (English)

    王爱林; 徐恒; 刘军; 韩圣辉

    2012-01-01

    Objective To compare the technical success rate and midterm results of cutting balloon angioplasty (CBA) to conventional balloon angioplasty (BA) for treatment of long segmental obstruction of the superficial femoral artery. Methods Between March 2009 and May 2010, 33 patients with long segmental obstruction of the superficial femoral artery treated with conventional angioplasty underwent cutting angioplasty. Follow-up consisted clinical examination and computed tomographic angiography at interval of one year. Results After conventional angioplasty there were still severe stenoses in the treated segments of the superficial femoral artery among the 33 selected patients. The stenosis rate decreased from 60% -95% (average 78%) post-conventional angioplasty to 15% -45% (average 36%) after cutting balloon angioplasty. Three patients complicated minor vessel dissection without other major complication. The one year patency of the cutting balloon angioplasty was 66% , which is better than the patency of the conventional balloon angioplasty ( 37% ) . Conclusion Cutting balloon angioplasty provides better vessel patency additional to balloon angioplasty in the treatment of the long segmental obstruction of the superficial femoral artery.%目的 分析评价在常规球囊扩张基础上加用切割球囊治疗股浅动脉长段闭塞的治疗效果和中期通畅率.方法 应用了切割球囊扩张治疗33例股浅动脉长段闭塞患者,导丝通过闭塞段后,首先应用常规球囊进行扩张后,进行动脉造影,对常规球囊扩张后仍有明显狭窄部位进行切割球囊扩张,再次动脉造影评价切割球囊扩张效果.术后对经过治疗的24例患者进行1年的中期随访,并与前期完成的24例单纯常规球囊扩张的1年通畅率进行比较,总结分析两者的中期通畅率、再狭窄的病变特点.结果 在股浅动脉长段闭塞部位进行常规球囊扩张后,均存在不同部位的短段重度狭窄,狭窄部位位于

  6. The Effect of Charcot Neuroarthropathy on Limb Preservation in Diabetic Patients with Foot Wound and Critical Limb Ischemia after Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Mehmet Burak Çildağ

    2017-01-01

    Full Text Available Objective. The aim of this article is to investigate one-year limb preservation rates after below-the-knee angioplasty in patients with diabetic foot wound who only have critical limb ischemia (CLI and those who have Charchot neuroarthropathy (CN accompanied by CLI. Methods. This single-center, retrospective study consists of 63 patients with diabetic foot wound who had undergone lower extremity balloon angioplasty of at least 1 below-the-knee (BTK vessel. Only those patients with postprocedural technical success of 100% were selected from the database. All patients were classified into two groups as patients with CLI and CN and patients with CLI only without CN. The Kaplan-Meier method was used to compare the limb preservation rates for the two groups. Results. There was no statistically significant difference between patient age, gender, diabetic disease duration, and comorbid disease such as chronic renal insufficiency, hypertension, and coronary artery disease of the two groups (p>0.05. Limb preservation in the 12 months was 59.1% in the CN group and 92.7% in the group without CN. Also, limb preservation rates between the two groups displayed statistically significant differences (p<0.005. Conclusion. This study showed that CLI can accompany CN in patients with diabetes. Limb preservation rates with endovascular treatment in diabetic patients with CLI only are better than in diabetic patients with CLI and CN.

  7. Differences in optical coherence tomographic findings and clinical outcomes between excimer laser and cutting balloon angioplasty for focal in-stent restenosis lesions.

    Science.gov (United States)

    Nishino, Masami; Lee, Yasuharu; Nakamura, Daisuke; Yoshimura, Takahiro; Taniike, Masayuki; Makino, Nobuhiko; Kato, Hiroyasu; Egami, Yasuyuki; Shutta, Ryu; Tanouchi, Jun; Yamada, Yoshio

    2012-10-01

    In-stent restenosis (ISR), especially focal ISR, after percutaneous coronary intervention (PCI) remains one of the major clinical problems in the drug-eluting stent (DES) era. Several reports have revealed that excimer laser coronary angioplasty (ELCA) is useful for ISR; however, detailed findings after ELCA are unknown. Therefore, we investigated the condition of the neointima after ELCA for ISR with optical coherence tomography (OCT) and compared the OCT findings and clinical outcome between ELCA and cutting-balloon angioplasty (CBA). Twenty-one consecutive patients with focal ISR who underwent ELCA or CBA were enrolled. All patients underwent 12- to 15-month follow-up coronary angiography. OCT was performed immediately after successful PCI to evaluate the neointimal condition in the ISR lesion. We compared the following OCT parameters between ELCA and CBA groups: maximal thickness of remaining in-stent neointima (MTN), number of tears, minimum lumen dimension (MLD), and minimum lumen area (MLA). We also evaluated clinical outcomes, including target vessel revascularization, acute myocardial infarction, death, and stent thrombosis. MLA in the ELCA group (n = 10) was significantly larger than in the CBA group, and number of tears in the ELCA group was significantly lower than in the CBA group. A trend was shown toward lower TLR with ELCA versus CBA (10.0% vs 45.5%). OCT immediately after ELCA for ISR lesions revealed larger lumen area and smaller number of tears compared with CBA, which may support favorable effects of ELCA for focal ISR.

  8. Eventos adversos e motivos de descarte relacionados ao reuso de produtos médicos hospitalares em angioplastia coronária Adverse events and reasons for discard related to the reuse of cardiac catheters in percutaneous transluminal coronary angioplasty

    Directory of Open Access Journals (Sweden)

    Margarete Ártico Batista

    2006-09-01

    the brand-new and reuse of medical equipment. METHOD: Sixty patients were studied (48.3% with unstable angina, 45% with acute myocardial infarction and 6.7% with other diagnoses. During the procedure and stay in the Intensive Coronary Unit, the occurrence of fever, hypotension or hypertension, chills, sudoresis, bleeding, nausea and vomits were observed. Seven products were evaluated: catheter introducer, catheter guides (0.35 and 0.014, catheter balloons for angioplasty, indeflators and manifolds. In total, 76 brand-new and 410 reused apparatuses were studied to verify the occurrence of discard, whether this happened before or during the procedure and for what reasons. P-values < 0.05 were considered signicant. RESULTS: Twenty-six patients presented adverse effects. Hypotension was the most common seen in 11(18.3% cases. There was no significant association between this adverse effect and reuse or not of the equipment. Three brand-new products and 55 of the reused products were discarded as they were incomplete. CONCLUSION: The adverse effects presented by patients submitted to coronary vessel angioplasty were not associated to the reuse of the medical equipment. The integrity and functionality were the main reasons of discard.

  9. Early and late effects of coumarin therapy started before percutaneous coronary intervention: Clinical, angiographic and cost-effective outcome of the Balloon Angioplasty and Anticoagulation Study (BAAS).

    Science.gov (United States)

    Ten Berg, J M; Kelder, J C; Suttorp, M J; Mast, E G; Bal, E T; Ernst, J M P G; Plokker, H W M

    2002-05-01

    Coronary angioplasty frequently creates a thrombogenic surface with subsequent mural thrombosis that may lead to acute complications and possibly stimulates the development of restenosis. Whether coumarins can prevent these complications is unclear. In the Balloon Angioplasty and Anticoagulation Study (BAAS), the effect of coumarins started before the procedure on early and late outcome was studied. Patients were randomised to aspirin only or to aspirin plus coumarins. Half of the patients were randomised to undergo six-month angiographic follow-up. Study medication was started one week before coronary angioplasty and the target international normalised ratio (INR) was 2.1-4.8 during angioplasty and six-month follow-up. 'Optimal' anticoagulation was defined as an INR in the target range for at least 70% of the follow-up time. In addition, cost-effectiveness of coumarin treatment was measured. At one year death, myocardial infarction, target-lesion revascularisation and stroke were observed in 14.3% of the 530 patients randomised to aspirin plus coumarin versus in 20.3% of the 528 patients randomised to aspirin alone (relative risk 0.71; 95% CI 0.54-0.93). The incidence of major bleedings and false aneurysms during hospitalisation was 3.2% and 1.0%, respectively, (relative risk 3.39; 95% CI 1.26-9.11). Optimal anticoagulation was an independent predictor of late thrombotic events (relative risk, 0.33; 95% CI, 0.19-0.57). Quantitative coronary analysis was performed of 301 lesions in the ASA group and of 297 lesions in the coumarin group. At six months, the minimal luminal diameter was similar in the ASA and coumarin group. However, optimal anticoagulation was an independent predictor of angiographic outcome at six months. Optimal anticoagulation led to a 0.21 mm (95% CI: 0.05-0.37) larger MLD as compared with suboptimal anticoagulation whereas aspirin use led to a 0.12 mm (95% CI -0.28-0.04) smaller MLD. When including all costs, the savings associated with coumarin

  10. The use of primary stenting or balloon percutaneous transluminal coronary angioplasty for the treatment of acutely occluded saphenous vein grafts. Results from the Brazilian National Registry - CENIC

    Directory of Open Access Journals (Sweden)

    Luiz Alberto Mattos

    2001-06-01

    Full Text Available OBJECTIVE: We conducted a comparative analysis of the in-hospital outcomes of patients who underwent primary percutaneous transluminal angioplasty (PTCA or stent implantation because of an acute myocardial infarction (AMI related to an acute vein graft occlusion. METHODS: Since 1991 the Brazilian Society of Hemodynamic and Interventional Cardiology has maintained a large database (CENIC. From these, we selected all consecutive patients, who underwent primary PTCA or stenting in the first 24 hours of AMI, with the target vessel being an occluded vein graft. Immediate results and major coronary events occurring up until hospital discharge were analyzed. RESULTS: During this period, 5,932 patients underwent primary PTCA or stenting; 158 (3% of the procedures were performed because of an acute vein graft occlusion. Stenting was performed in 74 (47% patients. Patients treated with stents had a higher success rate and lower mean residual stenosis compared with those who underwent primary balloon PTCA. The incidence of reinfarction and death were similar for stenting and balloon PTCA. CONCLUSION: Primary percutaneous treatment of AMI related to acute vein graft occlusion is still an uncommon practice. Primary stenting improved luminal diameter and offered higher rates of success; however, this strategy did not reduce the in-hospital reinfarction and death rate, compared with that occurring with PTCA treatment.

  11. Stroke risk associated with balloon based catheter ablation for atrial fibrillation: Rationale and design of the MACPAF Study

    Directory of Open Access Journals (Sweden)

    Schultheiss Heinz-Peter

    2010-07-01

    Full Text Available Abstract Background Catheter ablation of the pulmonary veins has become accepted as a standard therapeutic approach for symptomatic paroxysmal atrial fibrillation (AF. However, there is some evidence for an ablation associated (silent stroke risk, lowering the hope to limit the stroke risk by restoration of rhythm over rate control in AF. The purpose of the prospective randomized single-center study "Mesh Ablator versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation" (MACPAF is to compare the efficacy and safety of two balloon based pulmonary vein ablation systems in patients with symptomatic paroxysmal AF. Methods/Design Patients are randomized 1:1 for the Arctic Front® or the HD Mesh Ablator® catheter for left atrial catheter ablation (LACA. The predefined endpoints will be assessed by brain magnetic resonance imaging (MRI, neuro(psychological tests and a subcutaneously implanted reveal recorder for AF detection. According to statistics 108 patients will be enrolled. Discussion Findings from the MACPAF trial will help to balance the benefits and risks of LACA for symptomatic paroxysmal AF. Using serial brain MRIs might help to identify patients at risk for LACA-associated cerebral thromboembolism. Potential limitations of the study are the single-center design, the existence of a variety of LACA-catheters, the missing placebo-group and the impossibility to assess the primary endpoint in a blinded fashion. Trial registration clinicaltrials.gov NCT01061931

  12. Long-Term Results From the Contura Multilumen Balloon Breast Brachytherapy Catheter Phase 4 Registry Trial

    Energy Technology Data Exchange (ETDEWEB)

    Cuttino, Laurie W., E-mail: lcuttino@mcvh-vcu.edu [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Arthur, Douglas W. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Vicini, Frank [Michigan Healthcare Professionals/21st Century Onoclogy, Farmington Hills, Michigan (United States); Todor, Dorin [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Julian, Thomas [Allegheny Hospital, Temple School of Medicine, Pittsburgh, Pennsylvania (United States); Mukhopadhyay, Nitai [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States)

    2014-12-01

    Purpose: To describe the long-term outcomes from a completed, multi-institutional phase 4 registry trial using the Contura multilumen balloon (CMLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer. Methods and Materials: Three hundred forty-two evaluable patients were enrolled by 23 institutions between January 2008 and February 2011. All patients received 34 Gy in 10 fractions, delivered twice daily. Rigorous target coverage and normal tissue dose constraints were observed. Results: The median follow-up time was 36 months (range, 1-54 months). For the entire patient cohort of 342 patients, 10 patients experienced an ipsilateral breast tumor recurrence (IBTR). Eight of these IBTR were classified as true recurrences/marginal miss (TRMM), and 2 were elsewhere failures (EF). Local recurrence-free survival was 97.8% at 3 years. For the entire cohort, 88% of patients had good to excellent overall cosmesis. The overall incidence of infection was 8.5%. Symptomatic seroma was reported in only 4.4% of patients. A separate analysis was performed to determine whether improved outcomes would be observed for patients treated at high-volume centers with extensive brachytherapy experience. Three IBTR were observed in this cohort, only 1 of which was classified as a TRMM. Local recurrence-free survival at high-volume centers was 98.1% at 3 years. Overall cosmetic outcome and toxicity were superior in patients treated at high-volume centers. In these patients, 95% had good to excellent overall cosmesis. Infection was observed in only 2.9% of patients, and symptomatic seroma was reported in only 1.9%. Conclusion: Use of the CMLB for APBI delivery is associated with acceptable long-term local control and toxicity. Local recurrence-free survival was 97.8% at 3 years. Significant (grade 3) toxicity was uncommon, and no grade 4 toxicity was observed. Treatment at high-volume centers was associated

  13. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Samia de Freitas, E-mail: samiabrandao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Campos, Tarcisio Passos Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2013-06-15

    Objective: comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and methods: simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results: intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively, on the healthy tissue, on the balloon periphery and on the /{sub 1} and /{sub 2} tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively on the healthy tissue, on the target tumor and on the /{sub 1} and /{sub 2} infiltration zones. Conclusion: Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. (author)

  14. Target ballon-assisted antegrade and retrograde approach for recanalization of thrombosed fem-pop bypass graft using the outbreak catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Jung Won; Chung, Hwan Hoon; Lee, Seung Hwa; Yeom, Suk Keu; Cha, Sang Hoon [Dept. of Radiology, Korea University College of Medicine, Ansan Hospital, Ansan (Korea, Republic of)

    2016-01-15

    The subintimal arterial flossing with antegrade-retrograde intervention (SAFARI) technique is reportedly effective in severe peripheral vascular disease that cannot be treated with standard endovascular techniques including subintimal angioplasty. In this report, we used a target balloon with the Outback catheter to recanalize a thrombosed bypass graft that could not be treated successfully with SAFARI.

  15. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    Energy Technology Data Exchange (ETDEWEB)

    Kitrou, Panagiotis M., E-mail: panoskitrou@gmail.com [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece); Katsanos, Konstantinos [Department of Interventional Radiology, Guy' s and St. Thomas’ Hospitals, NHS Foundation Trust, King' s Health Partners, London SE1 7EH (United Kingdom); Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece)

    2015-03-15

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  16. Balloon catheter hypoxic pelvic perfusion with mitomycin C and melphalan for locally advanced tumours in the pelvic region : A phase I-II trial

    NARCIS (Netherlands)

    van Ijken, MGA; van Etten, B; Guetens, G; de Bruijn, EA; ten Hagen, TLM; Wiggers, T; Eggermont, AMM

    2005-01-01

    Aims: To investigate the feasibility of hypoxic pelvic perfusion (HPP), using balloon catheter techniques as treatment modality for locally advanced pelvic malignancies. Methods: In a phase I-II study, 16 patients with various non-resectabte pelvic tumours were treated with two HIPP with MMC and mel

  17. Double-balloon catheter and sequential vaginal prostaglandin E2 versus vaginal prostaglandin E2 alone for induction of labor after previous cesarean section.

    Science.gov (United States)

    Kehl, Sven; Weiss, Christel; Wamsler, Michael; Beyer, Jana; Dammer, Ulf; Heimrich, Jutta; Faschingbauer, Florian; Sütterlin, Marc; Beckmann, Matthias W; Schleussner, Ekkehard

    2016-04-01

    To evaluate the efficacy of inducing labor using a double-balloon catheter and vaginal prostaglandin E2 (PGE2) sequentially, in comparison with vaginal PGE2 alone after previous cesarean section. A total of 264 pregnant women with previous cesarean section undergoing labor induction at term were included in this prospective multicentre cohort study. Induction of labor was performed either by vaginal PGE2 gel or double-balloon catheter followed by vaginal PGE2. The primary outcome measure was the cesarean section rate. The cesarean section rate was 37 % without any statistically significant difference between the two groups (PGE2: n = 41, 37 % vs. balloon catheter/PGE2: n = 41, 42 %; P = 0.438). The median (range) number of applications of PGE2 [2 (1-10) versus 1 (0-8), P cesarean section were "no previous vaginal delivery" (OR 5.391; CI 2.671-10.882) and "no oxytocin augmentation during childbirth" (OR 2.119; CI 1.215-3.695). The sequential application of double-balloon catheter and vaginal PGE2 is as effective as the sole use of vaginal PGE2 with less applications and total amount of PGE2.

  18. Surface modification of poly(ethylene terephthalate) angioplasty balloons with a hydrophilic poly(acrylamide-co-ethylene glycol) interpenetrating polymer network coating.

    Science.gov (United States)

    Park, S; Bearinger, J P; Lautenschlager, E P; Castner, D G; Healy, K E

    2000-09-01

    An interpenetrating polymer network (IPN) of poly(acrylamide-co-ethylene glycol) (p(AAm-co-EG)) hydrogel was covalently grafted to polyethylene terephthalate (PET) angioplasty balloons to increase surface hydrophilicity and improve lubricity. A 2-step graft polymerization protocol was followed to first polymerize and cross-link acrylamide onto the substrate with a photosensitizer and/or oxygen plasma pretreatment. The effects of varying photo-initiation and plasma exposure times were investigated separately and conjunctively using water contact angles to obtain optimal coating deposition parameters. A poly(ethylene glycol) network was then grafted by swelling the preexisting polyacrylamide network to allow inter-diffusion of the monomer and cross-linker, which were then polymerized by photo-initiation. When the photo-initiation time was long enough to reach near gelation, pretreatment of PET with oxygen plasma did not offer significant benefit. X-ray photoelectron spectroscopy confirmed the presence of both polymer layers, and composition depth profiles supported the assessment that an interpenetrating network was formed. Tensile testing and application of Weibull statistics on unmodified and modified films indicated that the surface modification approach did not significantly alter the mechanical integrity of the material. These findings indicate that a p(AAm-co-EG) coating can be effectively deposited on PET surfaces without compromising the structural integrity of the substrate.

  19. Use of Reactor-Produced Radioisotopes for Prevention Restenosis After Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F.; Pipes, D.W.

    1999-12-21

    Coronary heart disease leads to myocardial infarction and is a major cause of death in the US. Myocardial infarctions result from atherosclerotic plaque deposits in the coronary arteries, reducing blood flow through these arteries which supply oxygen and nutrients to the heart muscle. The two major approaches for restoring adequate blood flow are coronary bypass graft surgery and coronary angioplasty. Angioplasty is a routinely used clinical procedure, where a deflated balloon attached to the end of a long catheter is inserted into an artery in the leg and then advanced through the aorta into the blocked regions of the coronary arteries. After positioning in the occluded region of the artery, the balloon is inflated with a pressurized saline solution which opens the artery restoring blood flow by pressing the atherosclerotic plaque into the vessel wall. Angioplasty is a widely performed procedure with the coronary arteries and is a much less expensive alternative to coronary bypass surgery. The best patients for angioplasty are those with single occlusions and this method is preferred over bypass grafting because of the significantly reduced expense. The reformation of plaque deposits in arteries (restenosis) following angioplasty, however, is a major clinical problem encountered in as high as 40 percent of patients. Because reduction of health care costs is a major national priority, development of effective new preventative methods for restenoses is an important national priority.

  20. Use of a Balloon Rectal Catheter in Magnetic Resonance Imaging of Complex Anal Fistula to Improve Detection of Internal Openings.

    Science.gov (United States)

    Zhan, Songhua; Yang, Shuohui; Lin, Jiang; Zhu, Qiong; Lu, Fang; Tan, Wenli; Cheng, Ruixin; Gong, Zhigang; Yang, Wei

    2016-01-01

    The aim of this study was to investigate the utility of a balloon rectal channel catheter (BRCC) in complex anal fistula magnetic resonance imaging (MRI). A prospective study was done on 54 patients with clinical diagnosis of complex anal fistula. Eighteen patients had preoperative MRI before and after inserting BRCC. Another 18 underwent MRI with BRCC and the rest without. Fistulas, internal openings, extensions, and abscesses were identified on MRI and compared with surgical findings. Intraindividual and interindividual differences with and without BRCC were analyzed. In intragroup patients, the accuracy of MRI in detecting the number of fistulas, internal openings, extensions, and abscesses before and after using BRCC was 100%/100%, 67%/90%, 95%/95%, and 100%/100%, respectively, with a significant difference on internal openings (P anal fistula.

  1. Dosimetric Improvements in Balloon Based Brachytherapy Using the Contura® Multi-Lumen Balloon (MLB Catheter to Deliver Accelerated Partial Breast Irradiation

    Directory of Open Access Journals (Sweden)

    Thomas Julian

    2010-04-01

    Full Text Available Purpose: Preliminary dosimetric findings in patients managed with the Contura® Multi-Lumen Balloon (MLB breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI on a multi-institutional phase IV registry trial were reviewed. Material and methods: CT-based 3D planning with dose optimization was performed for all patients. For the study, new ideal dosimetric goals were developed: 1 ≥ 95% of the prescribed dose (PD covering ≥ 90% of the target volume (TV, 2 a maximum skin dose ≤ 125% of the PD, 3 maximum rib dose ≤ 145% of the PD, and 4 the V150 ≤ 50 cc and V200 ≤ 10 cc. The frequency of concurrently achieving these dosimetric goals using the Contura® MLB was investigated.Results: 194 cases were evaluable. Employing the MLB, all ideal dosimetric criteria were achieved in 76% of cases.Evaluating dosimetric criteria separately, 90% and 89% of cases met the new ideal skin and rib dose criteria, respectively. In 96%, ideal TV coverage goals were achieved and in 96%, dose homogeneity criteria (V150 and V200 were met. For skin spacing ≥ 5-7 mm, the median skin dose was 121% of the PD and when < 5 mm, the median skin dose was 124.4%. For rib distancees < 5 mm, the median rib dose was reduced to 136.4% of the PD. For skin spacing < 7 mm and distance to rib < 5 mm, the median skin and rib doses were concurrently limited to 121% and 142.8% of thePD, respectively. Conclusions: The Contura® MLB catheter provides potential improvements in dosimetric capabilities (i.e., reduced skin and rib doses and improved TV coverage in many clinical scenarios.

  2. Factors influencing technical success and outcome of percutaneous balloon angioplasty in de novo native hemodialysis arteriovenous fistulas

    Energy Technology Data Exchange (ETDEWEB)

    Heye, Sam, E-mail: sam.heye@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Maleux, Geert, E-mail: geert.maleux@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Vaninbroukx, Johan, E-mail: johan.vaninbroukx@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Claes, Kathleen, E-mail: Kathleen.claes@uzleuven.be [University Hospitals Leuven, Department of Nephrology, Herestraat 49, 3000 Leuven (Belgium); Kuypers, Dirk, E-mail: dirk.kuypers@uzleuven.be [University Hospitals Leuven, Department of Nephrology, Herestraat 49, 3000 Leuven (Belgium); Oyen, Raymond, E-mail: raymond.oyen@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium)

    2012-09-15

    Objective: To determine predictors of technical success, dysfunction recurrence and patency after percutaneous transluminal angioplasty (PTA) of de novo dysfunctional hemodialysis arteriovenous fistulas (AVFs). Methods: Retrospective analysis of first time PTA of 167 AVF in 162 patients (100 men, 66 ± 13 years). Anatomical (location, length, grade and number of stenoses) and clinical variables (sex, age, prior AVF, diabetes mellitus and AVF age, side and location) were reviewed. Results: 217 stenoses or segmental occlusions were treated. Technical success rate (84.4%) was higher in radiocephalic AVF compared to brachial artery–median vein AVF (p = 0.030) and was negatively correlated with initial stenosis (p = 0.049). Dysfunction recurrence was seen in 52.7% and correlated negatively with technical success (p = 0.013) and AVF age (p = 0.008). Early dysfunction (within 6 months) was negatively correlated with AVF age (p = 0.016) and positively with diabetes (p = 0.003). Higher AVF age resulted in higher primary (p = 0.005) and secondary patency rates (p = 0.037–0.005). Conclusions: Technical success of PTA in hemodialysis AVF is affected by AVF type and initial stenosis and has significant effect on dysfunction recurrence, but not on AVF longevity. Younger AVF has increased risk for (early) recurrent dysfunction and lower patency rates. Patients with diabetes mellitus have higher risk for early dysfunction.

  3. Myxomavirus anti-inflammatory chemokine binding protein reduces the increased plaque growth induced by chronic Porphyromonas gingivalis oral infection after balloon angioplasty aortic injury in mice.

    Directory of Open Access Journals (Sweden)

    Alexandra R Lucas

    Full Text Available Thrombotic occlusion of inflammatory plaque in coronary arteries causes myocardial infarction. Treatment with emergent balloon angioplasty (BA and stent implant improves survival, but restenosis (regrowth can occur. Periodontal bacteremia is closely associated with inflammation and native arterial atherosclerosis, with potential to increase restenosis. Two virus-derived anti-inflammatory proteins, M-T7 and Serp-1, reduce inflammation and plaque growth after BA and transplant in animal models through separate pathways. M-T7 is a broad spectrum C, CC and CXC chemokine-binding protein. Serp-1 is a serine protease inhibitor (serpin inhibiting thrombotic and thrombolytic pathways. Serp-1 also reduces arterial inflammation and improves survival in a mouse herpes virus (MHV68 model of lethal vasculitis. In addition, Serp-1 demonstrated safety and efficacy in patients with unstable coronary disease and stent implant, reducing markers of myocardial damage. We investigate here the effects of Porphyromonas gingivalis, a periodontal pathogen, on restenosis after BA and the effects of blocking chemokine and protease pathways with M-T7 and Serp-1. ApoE-/- mice had aortic BA and oral P. gingivalis infection. Arterial plaque growth was examined at 24 weeks with and without anti-inflammatory protein treatment. Dental plaques from mice infected with P. gingivalis tested positive for infection. Neither Serp-1 nor M-T7 treatment reduced infection, but IgG antibody levels in mice treated with Serp-1 and M-T7 were reduced. P. gingivalis significantly increased monocyte invasion and arterial plaque growth after BA (P<0.025. Monocyte invasion and plaque growth were blocked by M-T7 treatment (P<0.023, whereas Serp-1 produced only a trend toward reductions. Both proteins modified expression of TLR4 and MyD88. In conclusion, aortic plaque growth in ApoE-/- mice increased after angioplasty in mice with chronic oral P. gingivalis infection. Blockade of chemokines, but not

  4. Successful Venous Angioplasty of Superior Vena Cava Syndrome after Heart Transplantation

    Directory of Open Access Journals (Sweden)

    Thomas Strecker

    2014-01-01

    Full Text Available Introduction. For patients with terminal heart failure, heart transplantation (HTX has become an established therapy. Before transplantation there are many repeated measurements with a pulmonary artery catheter (PAC via the superior vena cava (SVC necessary. After transplantation, endomyocardial biopsy (EMB is recommended for routine surveillance of heart transplant rejection again through the SVC. Case Presentation. In this report, we present a HTX patient who developed a SVC syndrome as a possible complication of all these procedures via the SVC. This 35-year-old Caucasian male could be successfully treated by balloon dilatation/angioplasty. Conclusion. The SVC syndrome can lead to pressure increase in the venous system such as edema in the head and the upper part of the body and further serious complications like cerebral bleeding and ischemia, or respiratory problems. Balloon angioplasty and stent implantation are valid methods to treat stenoses of the SVC successfully.

  5. Aortic valvuloplasty of calcific aortic stenosis with monofoil and trefoil balloon catheters: practical considerations

    NARCIS (Netherlands)

    S. Plante (Sylvain); M.J.B.M. van den Brand (Marcel); L.C.P. van Veen; C. di Mario (Carlo); C.E. Essed; K.J. Beatt (Kevin); P.W.J.C. Serruys (Patrick)

    1990-01-01

    textabstractIn order to evaluate the relation between balloon design (monofoil, trefoil) and valvular configuration, experimental aortic valvuloplasty was performed in four post-mortem hearts with calcific aortic stenosis of various morphology. The degree of obstruction of the aortic orifice was ass

  6. Percutaneous Balloon Dilatation and Catheter Maintenance Method in the Patients with Biliary Strictures after Living Donor Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dae Hong; Byun, Sung Su; Kim, Jeong Ho; Kim, Keon Kuk; Hwang, Hee Young; Kim, Hyung Sik; Choi, Hye Young; Park, Jae Hyung [Dept. of Gachon University School of Medicine, Gil Hospital, Incheon (Korea, Republic of)

    2013-04-15

    The aim of this study was to evaluate the therapeutic efficacy of the percutaneous balloon dilatation and catheter maintenance (BDCM) method for postoperative biliary strictures following living donor liver transplantation (LDLT). Eighteen patients (14 duct-to-duct anastomosis and 4 hepaticojejunostomy) with post-LDLT biliary stricture were treated by the percutaneous BDCM method. A good response was defined as residual stricture over 3.5 mm after repetitive BDCM and refractory response as residual stricture below 3.5 mm. If they demonstrated good results on follow-up studies after catheter withdrawal, all the patients quit the therapy. We evaluated the technical and clinical success rates, major complication rate, mean total procedure time and mean follow-up duration. The percutaneous BDCM method was technically successful without major complication. Nine patients improved biliary stricture (good response, mean 5.5 mm), and the other 9 patients showed residual stricture with the diameter below 3.5 mm (refractory response, mean 2.5 mm). However, all the patients were improved clinically without significant complication. The total procedure time was 1-15 months (mean 7.3 months) and follow-up duration was 6-54 months (mean 24 months). The percutaneous BDCM method for post-LDLT biliary strictures was an effective therapy even in the patients showing a refractory response. It seemed that total procedure time could be reduced if the response was determined earlier.

  7. [Obstruction of the nasal passage caused by a balloon catheter in a calf].

    Science.gov (United States)

    Rijkenhuizen, A B

    1993-01-01

    Decompression of the rumen as a supporting symptomatic therapy of recurrent bloat in calves and juvenile cattle is used regularly. The gas should be released for several days. This is facilitated by the use of a balloon stomach tube, which can be left in situ for up to five days. However, the use of this tube is not always without risks, which will be discussed on base of a patient.

  8. Cost-effectiveness of paclitaxel-coated balloon angioplasty and paclitaxel-eluting stent implantation for treatment of coronary in-stent restenosis in patients with stable coronary artery disease.

    Science.gov (United States)

    Bonaventura, Klaus; Leber, Alexander W; Sohns, Christian; Roser, Mattias; Boldt, Leif-Hendrik; Kleber, Franz X; Haverkamp, Wilhelm; Dorenkamp, Marc

    2012-07-01

    Recent studies have demonstrated the safety and efficacy of drug-coated balloon (DCB) angioplasty for the treatment of coronary in-stent restenosis (ISR). The cost-effectiveness of this practice is unknown. A Markov state-transition decision analytic model accounting for varying procedural efficacy rates, complication rates, and cost estimates was developed to compare DCB angioplasty with drug-eluting stent (DES) placement in patients with bare-metal stent (BMS)-ISR. Data on procedural outcomes associated with both treatment strategies were derived from the literature, and the cost analysis was conducted from a health care payer perspective. Effectiveness was expressed as life-years gained. In the base-case analysis, initial procedure costs amounted to €3,604.14 for DCB angioplasty and to €3,309.66 for DES implantation. Over a 12-month time horizon, the DCB strategy was found to be less costly (€4,130.38 vs. €5,305.30) and slightly more effective in terms of life expectancy (0.983 vs. 0.976 years) than the DES strategy. Extensive sensitivity analyses indicated that, in comparison with DES implantation, the cost advantage of the DCB strategy was robust to clinically plausible variations in the values of key model input parameters. The variables with the greatest impact on base-case results were the duration of dual antiplatelet therapy with acetylsalicylic acid and clopidogrel after DCB angioplasty, the use of generic clopidogrel, and variations in the costs associated with the DCB device. DCB angioplasty is a cost-effective treatment option for coronary BMS-ISR. The higher initial costs of DCB are more than offset by later cost-savings, predominantly as a result of reduced medication costs.

  9. Evaluating condom catheter balloon tamponade in non-traumatic postpartum haemorrhage resistant to medical management

    OpenAIRE

    Syed Nawaz Ahmad; Sunita Seth; Shefali Agarwal; Swati Choudhary

    2016-01-01

    Background: Obstetric haemorrhage remains the most important cause of maternal mortality worldwide accounting for 25% of maternal deaths annually. The aim of the study was to evaluate efficacy of a condom catheter assembly for uterine tamponade in the management of non-traumatic postpartum haemorrhage (PPH). Methods: It was a prospective interventional study done in a tertiary care hospital in New Delhi, India. Thirty three women with intractable PPH unresponsive to medical management were...

  10. Percutaneous transluminal coronary angioplasty. A review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Przybojewski, J.Z.; Weich, H.F.H. (Tygerberg Hospital, Stellenbosch (South Africa). Dept. of Internal Medicine)

    1984-01-25

    The purpose of this article is to review PTCA, percutaneous transluminal coronary angioplasty, which can be considered to be a truly revolutionary and fairly simple invasive form of intervention to atherosclerotic obstruction. The 'epidemic' of IHD, ischaemic heart disease, in the Republic of South Africa calls for the employment of this technique, which has already been carried out in a few teaching hospitals in this country. Very recently, modified balloon dilatation catheters have been used percutaneously in the non-operative transluminal correction of congenital coarctation of the aorta in infants and children, congenital pulmonary value stenosis, and hypoplasia and stenosis of the pulmonary arteries. It has also been employed for PTCA and for the simultaneous occlusion of coronary-bronchial artery anastomosis using a detachable balloon. The isotopes thallium 201 and technetium 99 were also used in scintiscanning.

  11. Cutting balloons for the treatment of vascular stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Tsetis, Dimitrios [University Hospital of Heraklion, Department of Radiology, Medical School of Crete, Heraklion (Greece); Morgan, Robert; Belli, Anna-Maria [St George' s Hospital, Department of Radiology, London (United Kingdom)

    2006-08-15

    The aim of this article is to review the mechanism, technical characteristics, biological response and clinical applications of cutting balloon angioplasty in peripheral vessels. The cutting balloon is a non-compliant, balloon catheter equipped with three-to-four microtome-sharp atherotomes. When used appropriately, it is safe and easy to use, with a high immediate success rate and few complications, provided oversizing is avoided. There is some evidence that pre-dilation with a standard or high-pressure balloon may also predispose to vascular rupture. The cutting balloon has proved to be beneficial in treating difficult complex lesions in the coronary arteries. Early experience in non-coronary vessels shows that cutting balloon angioplasty can be used to treat peripheral bypass anastomotic and haemodialysis fistula stenoses that are resistant to conventional high-inflation pressures. Its application in de novo peripheral arterial lesions and non-coronary in-stent restenosis is still under discussion. Theoretically, this device induces a smaller degree of vessel wall injury localised to the area of incisions and sparing the interincisional segments; however, this postulated reduction in restenosis rates has not been confirmed in clinical practice. (orig.)

  12. Utility of balloon assisted technique in trans catheter closure of very large (≥35 mm) atrial septal defects

    Science.gov (United States)

    Rangaswamy Balasubramanian, Vidhyakar; Selvaraj, Raja; Saktheeswaran, Maheshkumar; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    Background Very few published data is available on the outcomes of balloon assisted techniques (BATs) for trans catheter closure (TCC) of very large (Defined as ≥35 mm size) ostium secundum atrial septal defect (ASD). Objective To study the utility of BAT as against conventional techniques (CT) in TCC of very large ostium secundum ASD (≥35 mm) over the past 5-year period and to find out the association of different morphological features of the defects in relation to TCC outcomes. Study design and methods Descriptive single center retrospective study of patients with very large ostium secundum ASD (≥35 mm size) who were subjected to TCC. Results Thirty-three out of 36 patients with ≥35 mm ASD and complex morphological features underwent successful TCC. The study patients had high prevalence of absent aortic and posterior rims with posterior mal-alignment of the septum. BAT was successful in 28/31 (90.3%) patients while CT had a success rate of 16%. The mean trans-esophageal echocardiography (TEE) ASD size with BAT success 37 (SD 1.3) mm and CT failure 36.2 (SD 1.1) mm was not different (P=0.06). On univariate analysis of different morphological features, posterior mal alignment of the septum was associated failure of CT (P=0.01). There was no urgent referral for surgery and patients did well on follow up. Conclusions Balloon assisted device closure of (≥35 mm) ASD had 90% success rate. BAT helps in controlled delivery and device alignment in very large ASD with posterior malalignment of the septum and is often helpful when CT fails. PMID:24649421

  13. Cross-sectional Analysis of the Relationship between Paranasal Sinus Balloon Catheter Dilations and Industry Payments among Otolaryngologists.

    Science.gov (United States)

    Fujiwara, Rance J T; Shih, Allen F; Mehra, Saral

    2017-09-01

    Objective To characterize the relationship between industry payments and use of paranasal sinus balloon catheter dilations (BCDs) for chronic rhinosinusitis. Study Design Cross-sectional analysis of Medicare B Public Use Files and Open Payments data. Setting Two national databases, 2013 to 2014. Subjects and Methods Physicians with Medicare claims with Current Procedural Terminology codes 31295 to 31297 were identified and cross-referenced with industry payments. Multivariate linear regression controlling for age, race, sex, and comorbidity in a physician's Medicare population was performed to identify associations between use of BCDs and industry payments. The final analysis included 334 physicians performing 31,506 procedures, each of whom performed at least 11 balloon dilation procedures. Results Of 334 physicians, 280 (83.8%) received 4392 industry payments in total. Wide variation in payments to physicians was noted (range, $43.29-$111,685.10). The median payment for food and beverage was $19.26 and that for speaker or consulting fees was $409.45. One payment was associated with an additional 3.05 BCDs (confidence interval [95% CI],1.65-4.45; P < .001). One payment for food and beverages was associated with 3.81 additional BCDs (95% CI, 2.13-5.49; P < .001), and 1 payment for speaker or consulting fees was associated with 5.49 additional BCDs (95% CI, 0.32-10.63; P = .04). Conclusion Payments by manufacturers of BCD devices were associated with increased use of BCD for chronic rhinosinusitis. On separate analyses, the number of payments for food and beverages as well as that for speaker and consulting fees was associated with increased BCD use. This study was cross-sectional and cannot prove causality, and several factors likely exist for the uptrend in BCD use.

  14. A novel fluoroscopic-assisted balloon thrombectomy technique for thrombosed hemodialysis prosthetic grafts [corrected].

    Science.gov (United States)

    Kakkos, Stavros K; Haddad, Joseph A; Haddad, Georges K

    2010-01-01

    Previous studies have shown that stenosis of the arterial anastomosis of thrombosed hemodialysis (HD) grafts, unmasked after conventional thrombectomy, very often necessitate subsequent arterial angioplasty. The aim of this study was to describe a novel fluoroscopic-assisted balloon thrombectomy technique which permits simultaneous arterial angioplasty (should this is required) for thrombosed HD grafts. Thirty patients with 36 thrombotic episodes of their prosthetic HD grafts participated in this study. A balloon angioplasty catheter is placed beyond the arterial anastomosis, over a guidewire; the balloon is inflated with contrast solution under fluoroscopy and pulled back to remove the arterial thrombus from the anastomosis. Any coexisting stenosis revealed by balloon indentation is completely dilated at that time, rather than after the thrombectomy. Mechanical thrombolysis of the graft and venous outflow is then performed with the AngioJet catheter (Possis Medical, Inc). Technical and clinical success rates (the latter defined as one subsequent HD session) of the procedure were 100% and 94%, respectively. No complications, including arterial embolism, vessel rupture or pulmonary embolism, were encountered. Primary assisted patency at 3 and 6 months was 51% and 32%, respectively, while functional secondary patency at the same follow-up points was 78%. Our technique is safe and also effective in both short- and long-term follow-up. Because it offers convenience, since the treatment of arterial anastomotic stenoses is accomplished in one (rather than two) steps, this method deserves further investigation.

  15. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Sabharwal, Tarun, E-mail: tarun_sabharwal@yahoo.co.uk [Guy' s and St. Thomas' Hospitals, NHS Foundation Trust, Department of Radiology (United Kingdom)

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  16. Transhepatic catheter-directed thrombolysis for portal vein thrombosis after partial splenic embolization in combination with balloon-occluded retrograde transvenous obliteration of splenorenal shunt

    Institute of Scientific and Technical Information of China (English)

    Motoki Nakai; Morio Sato; Shinya Sahara; Nobuyuki Kawai; Masashi Kimura; Yoshimasa Maeda; Yumiko Ibata; Katsuhiko Higashi

    2006-01-01

    A 66-year-old woman underwent partial splenic embolization (PSE) for hypersplenism with idiopathic portal hypertension (IPH). One week later, contrastenhanced CT revealed extensive portal vein thrombosis (PVT) and dilated portosystemic shunts. The PVT was not dissolved by the intravenous administration of urokinase.The right portal vein was canulated via the percutaneous transhepatic route under ultrasonic guidance and a 4Fr. straight catheter was advanced into the portal vein through the thrombus. Transhepatic catheter-directed thrombolysis was performed to dissolve the PVT and a splenorenal shunt was concurrently occluded to increase portal blood flow, using balloon-occluded retrograde transvenous obliteration (BRTO) technique. Subsequent contrast-enhanced CT showed good patency of the portal vein and thrombosed splenorenal shunt.Transhepatic catheter-directed thrombolysis combined with BRTO is feasible and effective for PVT with portosystemic shunts.

  17. Initial Experience with Balloon-Occluded Trans-catheter Arterial Chemoembolization (B-TACE) for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Mitsunari, E-mail: mitunari@med-shimane.u.ac.jp; Yoshizako, Takeshi, E-mail: yosizako@med.shimane-u.ac.jp; Nakamura, Tomonori, E-mail: t-naka@med.shimane-u.ac.jp; Nakamura, Megumi, E-mail: megumi@med.shimane-u.ac.jp; Yoshida, Rika, E-mail: yoshidar@med.shimane-u.ac.jp; Kitagaki, Hajime, E-mail: kitagaki@med.shimane-u.ac.jp [Shimane University Faculty of Medicine, Department of Radiology (Japan)

    2016-03-15

    PurposeThis study was performed to evaluate the accumulation of lipiodol emulsion (LE) and adverse events during our initial experience of balloon-occluded trans-catheter arterial chemoembolization (B-TACE) for hepatocellular carcinoma (HCC) compared with conventional TACE (C-TACE).MethodsB-TACE group (50 cases) was compared with C-TACE group (50 cases). The ratio of the LE concentration in the tumor to that in the surrounding embolized liver parenchyma (LE ratio) was calculated after each treatment. Adverse events were evaluated according to the Common Terminology Criteria for Adverse Effects (CTCAE) version 4.0.ResultsThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). Only elevation of alanine aminotransferase was more frequent in the B-TACE group, showing a statistically significant difference (Mann–Whitney test: P < 0.05). While B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation, there was no statistically significant difference in incidence between the groups. Multivariate logistic regression analysis suggested that the significant risk factor for liver abscess/infarction was bile duct dilatation (P < 0.05).ConclusionThe LE ratio at the level of subsegmental showed a statistically significant difference between the groups (t test: P < 0.05). B-TACE caused severe adverse events (liver abscess and infarction) in patients with bile duct dilatation.

  18. Transaortic Intra-Aortic Balloon Pump Catheter Insertion through a Separate Saphenous Vein Graft in Patients with Severe Aortoiliac Disease

    Directory of Open Access Journals (Sweden)

    Faruk Toktas

    2014-01-01

    Full Text Available Background. Intra-aortic balloon pump (IABP is the most widely used mechanical assist device for hemodynamic support in high risk patients undergoing cardiac surgery. The aim of our study was to confirm whether transaortic route is a suitable alternative to allow IABP insertion in patients with severe aortoiliac diseases. Methods. This study included 7 consecutive patients undergoing coronary artery bypass grafting for severe coronary artery disease associated with severe aortoiliac disease. These patients could not be weaned from cardiopulmonary bypass and required the IABP support, which were placed through the ascending aorta. IABP catheter was inserted indirectly through a separate saphenous vein graft anastomosed to the ascending aorta by an end-to-side manner under a partial occluding clamp and advanced to the desired position in the descending thoracic aorta and exteriorly brought into the subcutaneous tissues in the jugulum. Results. The procedure was successfully performed in all the patients. The mean duration of IABP support was 54.0±13.4 hours. There were no in-hospital mortality and complications related to transaortic route. IABP removal did not require repeat sternotomy. At postoperative 6th month, multislice CT examination showed thrombotic occlusion at the remnant of the saphenous vein graft. Conclusions. This technique is a simple, reliable, and reproducible option in patients with severe aortoiliac disease in whom retrograde femoral route is not possible.

  19. Evaluation of the fetal dose during prophylactic placement of internal iliac artery balloon occlusion catheters in placenta accreta

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Sik [Dept. of Radiology, Gachon University Gil hospital, Incheon (Korea, Republic of); Ahn, Sung Min [Dept. of Radiological Science, Gachon University, Incheon (Korea, Republic of)

    2016-09-15

    Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38∼8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49∼18.27 mGy.

  20. Patient effective doses during intracoronary irradiation with a Rhenium 188 full filled balloon catheter after percutaneous transluminal coronary artery

    Energy Technology Data Exchange (ETDEWEB)

    Ponce V, L.; Peix G, A.; Llerena R, L.; Santana V, L. [Instituto de Cardiologia, La Habana (Cuba); Lopez D, A. [Hospital Hermanos Amejeiras, La Habana (Cuba)

    2006-07-01

    Intracoronary irradiation with a full filled Re188 balloon catheter treatment technique (IRT) after Percutaneous Transluminal Coronary Artery (PTCA) should represent an addition patient exposure dose with respect to common PTCA procedure. Our proposes were determinate the absorbed doses and estimate the risk for fatal cancer in 25 patients (15 males, mean age: 559 years old) treated during an IRT randomized clinical trial carried out in our institution as part of IAEA technical cooperation project. 20 Gy was always the prescribed doses for each patient. The average Re188 concentrated activity used and treatment time were 5256{+-}2371 MBq/ml in 1.5-2 ml and 466{+-}195 seconds, respectively. Two thermoluminescent dosimeters were attached in the chest and pelvis for each patient treated. Calibration for attenuation and scattered radiations was done. The maximal and mean value effective dose obtained for chest patient region were 18 mSv and 15{+-}6 mSv, respectively and for pelvis patient region the results were 10 mSv and 8{+-}3 mSv, respectively. The total risk to develop fatal cancer was 0.084% for patient treated. The patient effective doses is slightly superior to those reported for common procedures as PTCA. The IRT is considered a quite safe procedure, but in order to exposure radiation level optimization the continuous review of procedure should be constantly done. (Author)

  1. Laser angioplasty for cardiovascular disease

    Science.gov (United States)

    Okada, Masayoshi

    2005-07-01

    Recently, endovascular interventions such as balloon angioplasty, atherectomy and the stenting method, except for conventional surgery have been clinically employed for the patients with atheromatous plaques of the peripheral- and the coronary arteries, because the number of patients with arteriosclerosis is now increasing in the worldwide. Among these procedures, restenoses after endovascular interventions have been remarkably disclosed in 20-40 % of the patients who underwent percutaneous coronary interventions. Thus, there are still some problems in keeping long-term patency by means of endovascular techniques such as balloon angioplasty and atherectomy (1, 2). For reduction of these problems , laser angioplasty using Argon laser was applied experimentally and clinically. Based on excellent experimental studies, laser was employed for 115 patients with stenotic ,or obstructive lesions occluding more thasn 75 % of the peripheral and the coronary arteries angiographycally.

  2. NuMED CHEATHAM-PLATINUM STENT AND BALLOON IN BALLOON DELIVERY CATHETER FOR TREATMENT OF NATIVE COARCTATION OF THE AORTA

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ COARCTATION of the aorta (CoA) is a congenital heart defect involving a narrowing of the aorta. The narrowed segment called coarctation is most likely to happen in the segment just after the aortic arch. The narrowing can be removed by surgery or sometimes by a nonsurgical balloon dilation. However, aortic coarctation may recur even after successful surgery or balloon dilation. Fortunately, coarctation can now be treated with nonsurgical balloon dilation associated with implanting a stent using cardiac catheterization. Herein we reported our experience in a 19-year-old boy with CoA who underwent successful covered Cheatham-Platinum (CP) stent implantation for the coarctation.

  3. Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter.

    Science.gov (United States)

    Park, Taek Kyu; Yang, Jeong Hoon; Choi, Seung-Hyuk

    2016-07-01

    Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presents considerable difficulty. Additionally, surgical treatment might be unsuitable for high-risk patients due to comorbidities. Here, we report a case of an inadvertently-inserted 11.5-French hemodialysis catheter in the subclavian artery during internal jugular venous catheterization. We performed percutaneous closure of the subclavian artery using three 6-French Perclose Proglide® devices with a balloon tamponade in the proximal part of the subclavian artery. Closure was completed without embolic neurological complications.

  4. A successful experimental model for intimal hyperplasia prevention using a resveratrol-delivering balloon.

    Science.gov (United States)

    Tolva, Valerio; Mazzola, Silvia; Zerbi, Pietro; Casana, Renato; Albertini, Mariangela; Calvillo, Laura; Selmin, Francesca; Cilurzo, Francesco

    2016-03-01

    Restenosis due to intimal hyperplasia is a major clinical problem that compromises the success of angioplasty and endovascular surgery. Resveratrol (RSV) has demonstrated a beneficial effect on restenosis from angioplasty. Unfortunately, the physicochemical characteristics of RSV reduce the practicality of its immediate clinical application. This work proposes an experimental model aiming to setup an intravessel, elutable, RSV-containing compound. A 140 μg/mL RSV sterile injectable solution with a suitable viscosity for intravascular administration by drug-delivery catheter (RSV-c) was prepared. This solution was locally administered in the common iliac artery of adult male New Zealand White rabbits using a dedicated device (Genie; Acrostak, Geneva, Switzerland) after the induction of intimal hyperplasia by traumatic angioplasty. The RSV concentrations in the wall artery were determined, and the thickness of the harvested iliac arteries was measured over a 1-month period. The Genie catheter was applied in rabbit vessels, and the local delivery resulted in an effective reduction in restenosis after plain angioplasty. Notably, RSV-c forced into the artery wall by balloon expansion might accumulate in the interstitial areas or within cells, avoiding the washout of solutions. Magnification micrographs showed intimal proliferation was significantly inhibited when RSV-c was applied. Moreover, no adverse events were documented in in vitro or in vivo studies. RSV can be advantageously administered in the arterial walls by a drug-delivery catheter to reduce the risk of restenosis. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Guideline recommended door-to-balloon time can be achieved in transradial primary PCI — the usefulness of a dedicated radial guide catheter

    Energy Technology Data Exchange (ETDEWEB)

    Malaiapan, Yuvaraj, E-mail: yuvim@y7mail.com; Leung, Michael; Ahmar, Walid; Hutchison, Adam W.; Prasad, Sandhir; Katticaran, Therma; Cameron, James D.; Harper, Richard W.; Meredith, Ian T.

    2013-01-15

    Background: Radial access for primary percutaneous coronary intervention (PPCI) is well established in terms of safety and efficacy. However, there are limited data on the impact of the use of a single dedicated radial guide catheter in primary PCI using radial access. Aims: To determine the overall cardiac catheterisation laboratory to balloon time (CCL2BT) and door to balloon (D2BT) time in transradial PPCI. To determine the impact of a single dedicated radial guide catheter on CCLD2BT and D2BT in transradial PPCI compared to conventional transfemoral PPCI. Methods: The procedural and clinical outcomes of consecutive patients who had transradial primary PCI between 2005 and 2009 were included in this study and compared with a matched cohort who underwent transfemoral primary PCI. Results: Overall D2BT and inpatient MACE were similar between the radial (n = 53) and femoral (n = 53) groups (85 and 82 min, P = 0.889; 0% and 1.8% P = 0.317 respectively). An increase in the CCL2BT and procedural times was noted in the radial compared to the femoral group (34 min versus 29 min P = 0.028; 15.8 min versus 11.6 min P = 0.001). When a single radial guide catheter was used for the entire procedure, there was no difference in CCL2BT, D2BT and procedural times between the radial and femoral groups (31 min versus 29 min P = 0.599; 74 min versus 82 min P = 0.418; 50 min versus 47 min P = 0.086). Conclusion: The radial approach is safe and results in guideline recommended D2BT in STEMI. The use of a dedicated radial guide catheter reduces treatment time, demonstrating equivalent times to a femoral approach.

  6. Restenosis following balloon dilation of benign esophageal stenosis

    Institute of Scientific and Technical Information of China (English)

    Ying-Sheng Cheng; Ming-Hua Li; Ren-Jie Yang; Hui-Zhen Zhang; Zai-Xian Ding; Qi-Xin Zhuang; Zhi-Ming Jiang; Ke-Zhong Shang

    2003-01-01

    AIM: To elucidate the mechanism of restenosis following balloon dilation of benign esophageal stenosis.METHODS: A total of 49 rats with esophageal stenosis were induced in 70 rats using 5 ml of 50 % sodium hydroxide solution and the double-balloon method, and an esophageal restenosis (RS) model was developed by esophageal stenosis using dilation of a percutaneous transluminal coronary angioplasty (PTCA) balloon catheter. These 49 rats were divided into two groups: rats with benign esophageal stricture caused by chemical burn only (control group, n=21) and rats with their esophageal stricture treated with balloon catheter dilation (experimental group, n=28). Imaging analysis and immunohistochemistry were used for both quantitative and qualitative analyses of esophageal stenosis and RS formation in the rats, respectively.RESULTS: Cross-sectional areas and perimeters of the esophageal mucosa layer, muscle layer, and the entire esophageal layers increased significantly in the experimental group compared with the control group. Proliferating cell nuclear antigen (PCNA) was expressed on the 5th day after dilation, and was still present at 1 month. Fibronectin (FN)was expressed on the 1st day after dilation, and was still present at 1 month.CONCLUSION: Expression of PCNA and FN plays an important role in RS after balloon dilation of benign esophageal stenosis.

  7. A rectal balloon catheter as internal immobilization device for conformal radiotherapy of prostate cancer; Die Bedeutung eines Rektumballons als interne Immobilisation bei der konformalen Strahlentherapie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Gerstner, N.; Wachter, S.; Dorner, D.; Goldner, G.; Colotto, A.; Poetter, R. [Universitaetsklinik fuer Strahlentherapie und Strahlenbiologie, Wien (Austria)

    1999-05-01

    Background: As known from the literature, prostate motion depends on different bladder and/or rectum fillings. The aim of this study was to analyze the influence of a rectum balloon catheter, used as an internal immobilization device, on prostate and rectum motion during the treatment course. Moreover we have analysed if the balloon enables an increase of the distance between the prostate and the posterior rectum wall. Results: An increase of the distance between the prostate and the posterior rectal wall of 8 mm was observed at the base of the prostate when using the rectum balloon. Moreover prostate motion in the ventrodorsal direction {>=}4 mm (1 SD) was reduced from 6/10 patients (60%) to 1/10 patients (10%) using the rectal balloon. In general, deviations in the latero-lateral and cranio-caudal directions were less (mean {<=} 2 mm, 1 SD), no difference between both examination series (with and without balloon) was observed. Conclusion: Rectal balloon catheter offers a possibility to reduce prostate motion and rectum filling variations during treatment course. In addition it enables an increase in the distance between prostate and posterior rectal wall, which could enable an improved protection of the posterior rectal wall. (orig./AJ) [Deutsch] Hintergrund: Die Lageveraenderung der Prostata, bedingt durch unterschiedliche Harnblasen- und Rektumfuellungen, wurde bereits in einigen Studien untersucht. Ziel dieser Studie war es, zu pruefen, ob durch die Anwendung eines Rektumballonkatheters als interne Immobilisation der Prostata eine Reduktion der Prostataeigenbeweglichkeit moeglich ist. Darueber hinaus wurde untersucht, inwieweit durch den Rektumballon der Abstand zwischen Prostata und Rektumhinterwand vergroessert werden kann. Ergebnisse: Durch die Anwendung des Rektumballons konnte der Abstand zwischen Prostata und Rektumhinterwand an der Prostatabasis im Mittel um 8 mm vergroessert werden. Insgesamt konnte durch den Rektumballon die Prostatabewegung in

  8. Preoperative infrarenal abdominal aorta balloon catheter occlusion combined with Bakri tamponade reduced maternal morbidity of placenta increta/percreta.

    Science.gov (United States)

    Zeng, Chanjuan; Yang, Mengyuan; Ding, Yiling; Yu, Ling; Deng, Wen; Hu, Yu; Gong, Xiujuan

    2017-09-01

    Placenta increta/percreta is an increasingly common and life-threatening obstetric complication. It poses a management challenge to clinicians. The present study aimed to evaluate efficacy and safety of preoperative placement of infrarenal abdominal aorta balloon catheter (IAABC) alone or combined with Bakri tamponade for the management of cases with placenta increta/percreta. We retrospectively analyzed all cases with placenta increta/percreta at a tertiary referral teaching hospital in China between the year 2014 and 2017. Statistical analysis considered the individual subgroups: IAABC placed group and control group (without IAABC), and compared their maternal-fetal outcomes. The study covered 86 cases with placenta increta. For cases in the IAABC placed group (n = 48), significant reductions were noted in maternal morbidity including estimated blood loss (EBL), EBL ≥ 2000 mL, blood products transfusions, postpartum hemorrhage, operative time, intensive care unit admission, and postoperative days (P tamponade. In the control group, 10 cases were successful in preserving uterus by Bakri tamponade. Four cases failed and needed reoperation (3 uterine arterial embolism, 1 hysterectomy). There were no differences in fetal outcomes between the 2 groups. Eighteen cases were diagnosed with placenta percreta. Almost all the cases (17/18) inevitably underwent caesarean hysterectomy. Only 1 case was treated with a combination of IAABC and Bakri tamponade, and successfully reserved uterus. No differences were observed in any other outcomes, except for a significant less mean operative time (P = .017) in cases with IAABC placed (n = 10), compared with those without IAABC (n = 8). Only 1 case had a femoral artery thrombosis directly related to IAABC placement and recovered after conservative treatment. There was no maternal or neonatal death in this study. Prophylactic insertion of IAABC alone or combined with Bakri tamponade should be safe and

  9. Bilateral ophthalmoplegia and exophthalmos complicating central hemodialysis catheter placement.

    Science.gov (United States)

    Varelas, P N; Bertorini, T E; Halford, H

    1999-05-01

    We describe a 58-year-old woman who presented with bilateral ophthalmoplegia, exophthalmos, and headache and was found to have retrograde internal jugular vein flow secondary to a high-grade obstruction of the ipsilateral brachiocephalic vein from a previous hemodialysis catheter placement. The patient had also a high-flow dialysis graft in the ipsilateral arm. The cranial and extracranial venous system congestion resolved, and the signs disappeared soon after a balloon angioplasty and stent placement at the level of the obstruction.

  10. The Diagnostic Value of Endoscopic Balloon Catheter Usage for Detecting Early-Stage Primary Sclerosing Cholangitis in Endoscopic Retrograde Cholangiopancreatography:A Case Report

    Directory of Open Access Journals (Sweden)

    Burhan Ozdil

    2010-02-01

    Full Text Available A 34-year-old woman was admitted to our clinic with abdominal pain, jaundice and pruritus. Endoscopic retrograde cholangiopancreatography was performed for cholestasis. Endoscopic retrograde cholangiopancreatography (ERCP was judged as normal, after a standard ERCP cannula was used for the cholangiogram. However, marked canalicular irregularities were identified in cholangiography when pressurized contrast agent was administrated via balloon catheter. This cholangiographic view was thought to reveal an early-stage alteration of sclerosing cholangitis. Primary sclerosing cholangitis (PSC is a chronic cholestatic liver disease characterized by destruction and fibrosis of the bile ducts. The diagnosis of PSC is based on typical cholangiographic findings, supported by nonspecific clinical signs and symptoms, cholestatic liver biochemical tests, and liver biopsy. Cholangiography is considered to be the gold standard for the diagnosis of PSC. The diagnosis is easy when diffuse multifocal biliary strictures, the hallmarks of the disease, resulting in a ‘beaded’ appearance on ERCP is detected. However, it may reveal a normal image in an early stage of the disease when bile duct changings are not prominent. We think that balloon catheter ERCP appears to facilitate the diagnosis of early-stage primary sclerosing cholangitis.

  11. Double-balloon catheter for induction of labour in women with a previous cesarean section, could it be the best choice?

    Science.gov (United States)

    De Bonrostro Torralba, Carlos; Tejero Cabrejas, Eva Lucía; Marti Gamboa, Sabina; Lapresta Moros, María; Campillos Maza, Jose Manuel; Castán Mateo, Sergio

    2017-05-01

    We analysed the efficacy and safety of double-balloon catheter for cervical ripening in women with a previous cesarean section and which were the most important variables associated with an increased risk of repeated cesarean delivery. We designed an observational retrospective study of 418 women with unfavourable cervices (Bishop Score cesarean delivery, and induction of labour with a double-balloon catheter. Baseline maternal data and perinatal outcomes were recorded for a descriptive, bivariate, and multivariate analysis. A p value cesarean section were dystocia in the previous pregnancy (OR 1.744; CI 95% 1.066-2.846), the absence of previous vaginal delivery (OR 2.590; CI 95% 1.066-6.290), suspected fetal macrosomia (OR 2.410; CI 95% 0.959-6.054), and duration of oxytocin induction period (OR 1.005; CI 95% 1.004-1.006). The area under the curve was 0.789 (p cesarean delivery and unfavourable cervix. In our study, most women could have a vaginal delivery in spite of their risk factors for cesarean delivery. A multivariate model based on some clinical variables has moderate predictive value for intrapartum cesarean section.

  12. Peripheral pulsed laser angioplasty - 4-year clinical experience; Periphere gepulste Laserangioplastie - Erfahrungen nach 4jaehrigem klinischen Einsatz

    Energy Technology Data Exchange (ETDEWEB)

    Huppert, P.E. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik; Duda, S.H. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik; Kalighi, K. [Tuebingen Univ. (Germany). Abt. fuer Thorax-, Herz- und Gefaesschirurgie; Baumbach, A. [Tuebingen Univ. (Germany). Abt. 3, Medizinische Klinik; Seboldt, H. [Tuebingen Univ. (Germany). Abt. fuer Thorax-, Herz- und Gefaesschirurgie; Claussen, C.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik

    1994-02-01

    In 134 patients, 21 iliac, 91 femoropopliteal and 22 crural arterial occlusions were treated by percutaneous laser-assisteed angioplasty and in 32 patients femoropopliteal occlusions by conventional balloon angioplasty. Laser angioplasty could be performed in 126 patients following initial guide wire recanalisation using 9, 7 and 4.5-F multifibre catheters, respectively. In 72 patients a 308-nm excimer laser and in 54 patients a 504-nm pulsed day laser was used. Luminal opening by laser angioplasty was obtained in 102 of 126 (81%) procedures (9 incomplete catheter passages, 15 persistent occlusions). 95% of iliac, 90% of femoropopliteal and 77% of crural recanalisations including supplemental balloon dilatations (n=105) and stent implantations (n-24) succeeded technically. Clinical success rates at 1 (2) years after angioplasty weere 95% (89%) for iliac, 66% (63%) for femoropopliteal and 57% (50%) for crural treatments. Technical and clinical results of laser-assissted femoropopliteal recanalisations showed no significant differences in comparison to the results of conventional balloon angioplasty. The use of pulsed lasers for the treatment of peripheral arterial occlusive disease would require further technical improvements. (orig.) [Deutsch] Bei 134 Patienten mit arterieller Verschlusskrankheit wurden 21 iliakale, 91 femoropopliteale und 22 krurale Okklusionen einer Behandlung durch perkutane laserassistierte Angioplastie zugefuehrt und bei 32 Patienten femoropoliteale Okklusionen vergleichsweise einer konventionellen Ballonangioplastie. 126 Laserangioplastien konnten mit 9, 7 und 4,5-F-Multifaserkathetern nach initialer Fuehrungsdrahtpassage durchgefuehrt werden. Bei 72 Eingriffen wurde ein 308-nm-Excimerlaser und bei 54 ein 405-nm-Farbstofflaser verwendet. Eine Lumeneroeffnung gelang bei 102 von 126 (81%) Laserangioplastien (9 inkomplette Katheterpassagen, 15 persistierende Okklusionen). 95% iliakaler, 90% femoropoplitealer und 77% kruraler laserassistierter

  13. Restenosis of the coronary stenotic lesions treated by holmium:YAG laser coronary angioplasty

    Science.gov (United States)

    Miyazaki, Shunichi; Nonogi, Hiroshi; Goto, Yoichi; Itoh, Akira; Ozono, Keizaburo; Daikoku, Satoshi; Haze, Kazuo

    1994-07-01

    Clinical efficacy of newly developed Holmium YAG laser coronary angioplasty (HLCA) was assessed for 30 patients with angina. There were 12 near left main trunk (LMT) lesions and 4 aorto- ostial lesions. Adjunctive balloon angioplasty was performed for 25 of 30 lesions. Delivered energy ranged from 1.5 to 2.5 watts/pulse and the total exposure time ranged from 6 to 55 seconds. External diameter of laser catheter was 1.5 mm for 13 lesions, 1.4 mm for 17 lesions, and 1.7 mm for 5 lesions. Laser success, defined as 20% reduction of stenotic ratio, was obtained in 21 of 30 (70%) and overall procedural success rate was 93%. There were 3 cases with acute coronary occlusions relieved by adjunctive balloon angioplasty and one coronary perforation without manifestation of cardiac tamponade. There were no large coronary dissection which involved more than 5 mm of the coronary artery. Follow up coronary angiography after 3 months showed restenosis in 14 of 27 patients (52%). Percent stenosis after lasering (56%) was similar to that at 3 months after (62%). HLCA is acutely effective treatment for lesions near LMT, because of low incidence of large coronary dissection. However, angiographical restenosis rate is high at 3 months after HLCA. This may be attributed to the relatively large residual stenosis after the procedure and vessel injury caused by shock wave.

  14. A randomized trial assessing the effect of coumarins started before coronary angioplasty on restenosis: results of the 6-month angiographic substudy of the Balloon Angioplasty and Anticoagulation Study (BAAS).

    Science.gov (United States)

    ten Berg, Jurriën M; Kelder, Johannes C; Suttorp, Maarten Jan; Verheugt, Freek W A; Plokker, H W Thijs

    2003-01-01

    Thrombus formation during coronary angioplasty may play a role in the restenosis process. The effect of pretreatment with coumarins on 6-month angiographic outcome was studied. In addition, the effect of "optimal" anticoagulation, defined as an international normalized ratio >70% of the follow-up time in the target range, was studied. A total of 261 patients were assigned to aspirin alone (ASA group) and 270 patients to aspirin plus coumarins started 1 week before the procedure (coumarin group). The mean international normalized ratio was 2.7 +/- 1.2 at the start of the procedure and 3.1 +/- 0.5 during follow up. Quantitative coronary analysis was performed on 301 lesions in the ASA group and of 297 lesions in the coumarin group. At 6 months, the minimal luminal diameter was similar in the ASA and coumarin groups. Optimal anticoagulation, however, was an independent predictor of a larger minimal luminal diameter at follow up (P =.01). Overall, coumarins do not improve angiographic outcome 6 months after coronary angioplasty.

  15. Intravascular ultrasound-guided angioplasty of hemodialysis loop graft in a patient with contrast allergy.

    Science.gov (United States)

    Casey, Patrick E; Miranda, Charles J; Al-Khaffaf, Haytham; Woodhead, Peter M

    2014-01-01

    A surveillance duplex scan detected a stenosis within a left groin hemodialysis loop graft in a 57-year-old woman who was allergic to both iohexol and gadolinium contrast agents. This precluded the use of standard angioplasty treatment techniques. Intravascular ultrasound (IVUS) uses a catheter mounted with a miniaturized ultrasound probe to produce detailed cross-sectional vessel images. Clinically, it has been used in the assessment of coronary artery disease but has also supplemented standard angiography techniques in the assessment of peripheral vascular and hemodialysis access lesions. IVUS was utilized as the solitary imaging modality to identify the graft stenosis and guide the placement of a 6 mm diameter angioplasty balloon. Two areas of stenosis were successfully dilated and subsequent IVUS re-examination showed abolition of the stenosis. Twelve-month follow-up surveillance scan showed that the graft remained functional with good flow rates. In the setting of contrast allergy, IVUS may provide a valid and safe tool in the localization and treatment of peripheral vessel stenosis, including arteriovenous fistula angioplasty. To our knowledge this is the first reported use of IVUS for hemodialysis graft salvage adopting a completely 'contrast-free' technique. More studies are required to establish the true role of IVUS in the management of hemodialysis access angioplasty, but this successful case contributes valuable information to the literature on its clinical application.

  16. Detecting DNA synthesis of neointimal formation after catheter balloon injury in GK and in Wistar rats: using 5-ethynyl-2'-deoxyuridine

    Directory of Open Access Journals (Sweden)

    Guo Jingsheng

    2012-12-01

    Full Text Available Abstract Background Neointimal formation plays an important role in the pathogenesis of coronary restenosis after percutaneous coronary intervention (PCI, especially in patients with diabetes mellitus. Recently, some studies have shown that 5-ethynyl-2'-deoxyuridine (EdU incorporation can serve as a novel alternative to the 5-bromo-2'-deoxyuridine (BrdU antibody detection method for detection of DNA synthesis in regenerating avian cochlea, chick embryo and the adult nervous system. However, few studies have been performed to assess the suitability of EdU for detecting DNA synthesis in vascular neointima. Methods The carotid artery balloon injury model was established in Goto-Kakizaki (GK and Wistar rats. A Cell-LightTM EdU Kit was used to detect EdU-labeled cell nuclei of common carotid arteries at day 7 after catheter balloon injury. Different methods of injecting EdU were tested. The protein levels of proliferating cell nuclear antigen (PCNA and p-Akt (Ser473, as well as the mRNA levels of PCNA were evaluated by Western blotting and quantitative real-time PCR (qRT-PCR, respectively. Immunohistochemical staining was also employed to visualize PCNA-positive cells. Results At day 7 after catheter balloon injury, far more EdU-positive and PCNA-positive cells were observed in GK rats. When comparing groups that received different EdU doses, it was found that the percentage of EdU-positive cells at a dose of 100 mg/kg body weight was than at doses of 25 mg/kg and 50 mg/kg. The number of positive cells was significantly higher in the repeated injection group compared to the single injection group. Further, after balloon injury DNA synthesis in GK rats was more notable than in Wistar rats. Neointimal formation in GK rats was more obvious than in Wistar rats. The protein levels of PCNA and p-Akt (Ser473 and the mRNA levels of PCNA were increased in injured rats as compared to uninjured rats, and were significantly higher in GK rats than in Wistar rats

  17. Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation.

    Science.gov (United States)

    Williams, Andrew R; Koo, Bon-Kwon; Gundert, Timothy J; Fitzgerald, Peter J; LaDisa, John F

    2010-08-01

    Abnormal blood flow patterns promoting inflammation, cellular proliferation, and thrombosis may be established by local changes in vessel geometry after stent implantation in bifurcation lesions. Our objective was to quantify altered hemodynamics due to main vessel (MV) stenting and subsequent virtual side branch (SB) angioplasty in a coronary bifurcation by using computational fluid dynamics (CFD) analysis. CFD models were generated from representative vascular dimensions and intravascular ultrasound images. Time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and fractional flow reserve (FFR) were quantified. None of the luminal surface was exposed to low TAWSS (stenting introduced eccentric areas of low TAWSS along the lateral wall of the MV. Virtual SB angioplasty resulted in a more concentric region of low TAWSS in the MV distal to the carina and along the lateral wall of the SB. The luminal surface exposed to low TAWSS was similar before and after virtual SB angioplasty (rest: 43% vs. 41%; hyperemia: 18% vs. 21%) and primarily due to stent-induced flow alterations. Sites of elevated OSI (>0.1) were minimal but more impacted by general vessel geometry established after MV stenting. FFR measured at a jailed SB was within the normal range despite angiographic stenosis of 54%. These findings indicate that the most commonly used percutaneous interventional strategy for a bifurcation lesion causes abnormal local hemodynamic conditions. These results may partially explain the high clinical event rates in bifurcation lesions.

  18. Balloon angioplasty for native coarctation in children: one year follow-up results%球囊扩张成形术治疗儿童主动脉缩窄一年随访

    Institute of Scientific and Technical Information of China (English)

    何岚; 吴琳; 刘芳; 齐春华; 陆颖; 张丹艳; 黄国英

    2014-01-01

    Objective Balloon angioplasty is an alternative to surgical repair for coarctation of the aorta in children.However,its role in the treatment of neonates and infants younger than 3 months old remains controversial.The purpose of this study was to evaluate the efficacy and safety of balloon angioplasty for native coarctation by comparing children in different age groups.Method This is a retrospective clinical study including 37 children treated with balloon angioplasty for native coarctation from January 2006 to December 2012.A total of 37 patients consisting of 26 boys and 11 girls underwent the procedure,with median age 10 months (range from 7 days to 6 years) and the mean body weight was 6.3 (2.5-17.0) kg.The indication of the procedure includes discrete native coarctation without aortic arch hypoplasia and a peak-to-peak systolic pressure gradient > 20 mmHg (1 mmHg =0.133 kPa) across aortic coarctation.During one year follow-up,the approach artery injury,recoarctation and aneurysm formation were particularly assessed.Result We classified these patients into two groups according to their age.Group A consisted of 25 patients younger than 3 months and Group B of 12 patients older than 3 months.There was no significant difference between the two groups in systolic pressure gradient before balloon angioplasty (P > 0.05).The mean peak systolic gradient decreased from (38 ± 18) mmHg to (12 ± 11) mmHg immediately after angioplasty in group A and from (47 ±18) to (17 ± 12) mmHg in group B (P =0.000 for both).Meanwhile,the mean diameter of the coarctation segment increased from (1.8 ± 0.7) to (3.7 ± 1.1) mm after angioplasty in group A and from (2.6 ± 1.5) to (5.5 ± 1.8) mm in group B (both P =0).The initial successful balloon angioplasty (immediate postangioplasty peak pressure gradient < 20 mmHg) was achieved in all the 37 patients; 32 patients (86.5%) have been followed up for one year.Approach arterial complications occurred in 3 patients (9.4

  19. Use of the AngioSculpt scoring balloon for infrapopliteal lesions in patients with critical limb ischemia: 1-year outcome.

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen; Cagiannos, Catherine; Verbist, Jürgen; Peeters, Patrick

    2009-01-01

    The AngioSculpt Scoring Balloon Catheter (AngioScore, Inc., Fremont, CA) is composed of a semicompliant balloon encircled by three nitinol spiral struts providing targeted lesion scoring on balloon inflation. Between April 2005 and April 2006, procedural and follow-up data on 31 patients (mean age 76 years; 54.8% males) endovascularly treated for severe infrapopliteal disease were collected. The AngioSculpt catheter was used to treat 36 complex, tibioperoneal, atherosclerotic lesions. All patients had symptomatic critical limb ischemia (Rutherford 4-5) and single-vessel runoff to the ankle. Complication-free survival at 1 month was the safety end point, whereas primary patency and limb salvage were the efficacy end points evaluated at 1 year. The AngioSculpt balloon was successfully inflated in all 36 target lesions. Eleven patients (35.5%) required additional stenting for minor dissections or suboptimal stenosis reduction. The 1-month complication-free survival was 96.8%. One-year survival, primary patency, and limb salvage rates were 83.9 +/- 6.6%, 61.0 +/- 9.3%, and 86.3 +/- 6.4%, respectively. The 1-year data show the AngioSculpt Scoring Balloon Catheter to be an effective and safe treatment for infrapopliteal, atherosclerotic lesions in patients with critical limb ischemia. However, more patients, a longer follow-up, and randomized studies comparing it with conventional balloon angioplasty and stenting in the infrapopliteal region are required.

  20. Prospective multi-centre randomised trial comparing induction of labour with a double-balloon catheter versus dinoprostone

    DEFF Research Database (Denmark)

    Løkkegaard, E; Lundstrøm, M; Kjær, Michael;

    2015-01-01

    group (difference not significant). After 24 h, 55.3% had given birth in the balloon group versus 54.3% in the dinoprostone group. Additional oxytocin stimulation was used more often in the balloon (46%) compared with that in the dinoprostone (34%) (relative risk: 1.34 (95%CI 1.16 -1.54) group....... Caesarean section rates and neonatal outcome were similar. Overall, the two methods for induction were comparable with regard to efficacy and safety....

  1. Nursing of catheter incarceration in patients with indwelling balloon urethral catheter%留置气囊导尿管烧伤患儿尿管嵌顿的护理

    Institute of Scientific and Technical Information of China (English)

    廖秀梅; 柴玉兰; 狄桂萍

    2013-01-01

    patients,the structure,know performance,operation and notes of balloon urethral catheter,and correctly grasp the decannulation method of the balloon catheter.

  2. Placement of hemodialysis catheters through stenotic or occluded central thoracic veins.

    Science.gov (United States)

    Haller, Claude; Déglise, Sébastien; Saucy, Francois; Mathieu, Claudine; Haesler, Erik; Doenz, Francesco; Corpataux, Jean Marc; Qanadli, Salah Dine

    2009-07-01

    A method for hemodialysis catheter placement in patients with central thoracic venous stenosis or occlusion is described and initial results are analyzed. Twelve patients, with a mean age of 63.2 years (42-80 years), with central venous stenosis or occlusion, and who required a hemodialysis catheter were reviewed. All lesions were confirmed by helical CT or phlebography. Five patients had stenosis while seven patients were diagnosed with an occlusion of thoracic central veins. All patients were asymptomatic, without sign of superior vena cava syndrome. After percutaneous transstenotic catheterization or guidewire-based recannalization in occlusions, a balloon dilatation was performed and a stent was placed, when necessary, prior to catheter placement. Technical success was 92%. Three patients had angioplasty alone and nine patients had angioplasty with stent placement. Dialysis catheters were successfully inserted through all recannalized accesses. No immediate complication occurred, nor did any patient develop superior vena cava syndrome after the procedure. The mean follow-up was 21.8 months (range, 8-48 months). Three patients developed a catheter dysfunction with fibrin sheath formation (at 7, 11, and 12 months after catheter placement, respectively). Two were successfully managed by percutaneous endovascular approach and one catheter was removed. In conclusion, for patients with central venous stenosis or occlusion and those who need a hemodialysis catheter, catheter insertion can be reliably achieved immediately after endovascular recannalization with acceptable technical and long-term success rates. This technique should be considered as an alternative procedure for placing a new hemodialysis catheter through a patent vein.

  3. The usefulness of wire-loop technique for percutaneous angioplasty of insufficient hemodialysis fistula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hun; Goo, Dong Erk; Kim, Dae Ho; Choi, Deuk Lin; Moon, Chul [College of Medicine, Soonchunhyang University, Seoul (Korea, Republic of)

    2000-10-01

    To evaluate the usefulness of the wire-loop technique, used to perform percutaneous transluminal angioplasty (PTA) in occluded arteriovenous fistula when standard methods fail to pass the balloon catheter across the stenotic segment. In 30 patients (M:F = 14:16; aged 27-77 (mean, 51.3) years), the Wire-Loop technique was used to perform percutaneous transluminal angioplasty of insufficiently hemodialysed arteriovenous fistula where a balloon catheter had failed to pass through the stenotic lesion after a guide wire had successfully passed. Native and Gore-tex fistula were used in 22 and eight cases, respectively.Sixteen stenoses were located in the central vein, and fourteen in the peripheral. The puncture sites used in order to perform the technique were the femoral vein in all cases of central stenosis; three basilic, four cephalic, and five femoral veins in cases of peripheral stenosis and one femoral and one radial artery in cases of anastomotic stenosis. The guide wire was passed through the stenotic lesion, pulled out using the snare technique, and then stretched in order to tighten it. The balloon catheter was then passed through the lesion and traditional balloon angioplasty was performed. The technical success rate and complications of the technique, and the patency rate of recanalized arteriovenous fistula, were evaluated. In 26 of the thirty patients, (86.7%), the procedure was technically successful. In the remaining four cases, failure was due to venous dissection (n=1), marked residual stenosis (n=2), or cardiac arrest (n=1) during the procedure. The average procedure time was 105 (range, 40-210) minutes, and in three cases rupture of the vein occurred. The patency rate of PTA was 80% (24/30) at four months, 63% (19/30) at six months, and 30% (9/30) at twelve months. The expected technical success rate of traditional PTA, without the Wire-Loop technique, would have been 79.3%, but using the technique, the rate increased to 86.7%. The Wire

  4. Regional differences in elastic recoil after percutaneous transluminal coronary angioplasty: a quantitative angiographic study

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); B.H. Strauss (Bradley); P.W.J.C. Serruys (Patrick); W.R.M. Hermans (Walter)

    1991-01-01

    textabstractThe immediate result of percutaneous transluminal coronary angioplasty is influenced by both plastic and elastic changes of the vessel wall. To evaluate the amount of elastic recoil after coronary balloon angioplasty, the minimal luminal cross-sectional area of the largest balloon used a

  5. Urinary catheters

    Science.gov (United States)

    ... incontinence. There is no tube placed inside the penis. Instead, a condom-like device is placed over the penis. A tube leads from this device to a ... too small Bladder spasms Constipation The wrong balloon size Urinary tract infections POSSIBLE COMPLICATIONS Complications of catheter ...

  6. Stunning and Right Ventricular Dysfunction Is Induced by Coronary Balloon Occlusion and Rapid Pacing in Humans: Insights From Right Ventricular Conductance Catheter Studies.

    Science.gov (United States)

    Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P

    2017-06-06

    We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, Pright coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. Medical operating personnel exposition levels during intracoronary irradiation using a Re188 full filled balloon catheter after percutaneous transluminal coronary artery

    Energy Technology Data Exchange (ETDEWEB)

    Ponce V, F.; Peix G, A.; Llerena R, L.; Santana V, L. [Instituto de Cardiologia, La Habana (Cuba); Lopez D, A. [Hospital Hermanos Amejeiras, La Habana (Cuba)

    2006-07-01

    The intracoronary irradiation using a full filled conventional balloon catheter with Rhenium 188 (Re188) after Percutaneous Transluminal Coronary Artery (PTCA) is a new relative treatment technique to reduce restenosis where the medical operating personnel are exposed to additional radiation ionizing level in the cath lab. In this study a radiation exposure level to medical operating personnel in the cath lab were measured with a Geiger Muller detector in 7 place to different distance from patient (to chest and abdominal region) catheter tabletop during a randomized clinical trial carried out in 25 patients whose were treated. The average concentrated Re188 activity used and treatment time were 5256{+-}2371 MBq/ml in 1.5-2 ml and 466{+-}195 seconds. At 3 cm from right arm patient the average maximum exposition rate were 0,63 mSv/h and 0,51 mSv h, to chest and abdominal patient level, respectively, where also average exposed dose per treated patient was 0,06 mSv and 0,05 mSv, respectively. Our results show that intracoronary irradiation with Re188 in the cath lab do not increase significatively the exposure radiation level to medical operating staff during treatment procedure and it is safe according national and international radiation protection regulations. (Author)

  8. Percutaneous laser-assisted thermal coronary angioplasty in native coronary arteries and saphenous vein grafts: initial results and angiographic follow-up.

    Science.gov (United States)

    Linnemeier, T J; Rothbaum, D A; Cumberland, D C; Landin, R J; Hodes, Z I; Ball, M W

    1990-01-01

    Percutaneous laser-assisted thermal coronary angioplasty was attempted in 29 vessels (27 patients): 10 left anterior descending, 2 left circumflex and 17 mid-shaft (non-anastomotic) saphenous vein grafts. Argon or YAG laser thermal energy was applied via a 1.3, 1.6 or 1.9 mm metal capped probe followed by conventional balloon angioplasty in 27 vessels and sole thermal laser therapy in two vessels. The laser probe successfully crossed 83% (24/29) of vessels and subsequent balloon dilatation increased the success rate to 93% (25/27). Perforation occurred in a vein graft resulting in one in-hospital death post repeat emergency coronary artery bypass graft surgery. Angiographic follow-up was obtained in 85% (24/28) of vessels. Angiographic restenosis ( greater than 50% reduction in lumen diameter) occurred in 27% (3/11) of native coronary arteries and 62% (8/13) of saphenous vein grafts. Therefore, despite high initial success rates, the application of laser thermal energy with small laser probes relative to vessel size, followed by conventional balloon angioplasty, does not appear to alter restenosis. Further evaluation of coronary laser systems should be continued only with catheters that are capable of creating channels closer to the size of the vessel treated.

  9. Initial clinical experience with a new pulsed dye laser device in angioplasty of limb ischemia and shunt fistula obstructions

    Energy Technology Data Exchange (ETDEWEB)

    Zwaan, M.; Weiss, H.D.; Kagel, H.; Gmelin, E.; Rinast, E. (Medical University of Luebeck (Germany). Department of Radiology); Goethlin, J.H. (Sahlgrenska Sjukhuset, Goeteborg (Sweden)); Kummer, D. (Medical University of Luebeck (Germany). Department of Angiology and Geriatry); Scheu, M. (Medical Laser Center Luebeck (Germany))

    Selective plaque ablation with laser radiation at 405-530 nm in vitro has been reported. The possibilities are investigated of a new pulsed dye laser device for in vivo recanalization of arteries in ischemic lower limbs and stenoses/occlusions of arterio-venous hemo-dialysis shunt fistulae. A specially designed 9F or 7F multifiber catheter was used for treatment of 10 patients with lower limb artery obliterations and 11 patients with malfunctioning hemodialysis access fistulae (HAF). The recanalization technical success was 5/5 in the iliac arteries (IA), 4/5 in the superficial femoral arteries (SFA), and 11/11 in the HAF. Early re-occlusions occurred in one SFA and IA, respectively, caused by very bad run-off. There was one clinically insignificant SFA perforation. Additional balloon angioplasty was considered necessary in 10/16 lesions. Mean ankle-arm index increased from 0.68 to 0.97. With two exceptions all HAF patients were re-integrated in the dialysis program. Pulsed dye laser angioplasty promises to be an effective and fast method for plaque ablation debulking. The first clinical experience confirms previous in vitro results. In particular laser recanalization may become the method of choice for treatment of rigid HAF obstructions and it seems to be superior to vascular surgery or balloon angioplasty alone. (author). 15 refs.; 2 figs.

  10. Venous rupture complicating hemodialysis access angioplasty: percutaneous treatments and outcomes

    Energy Technology Data Exchange (ETDEWEB)

    La, Young Jong; Goo, Dong Erk; Kim, Dae Ho; Lee, Hae Kyoung; Hong, Hyun Suk; Kwon, Gui Hyang; Choi, Duk Lin; Ynag, Sung Boo [College of Medicine, Soonchunhyang Univ., Seoul (Korea, Republic of)

    2002-03-01

    To evaluate the usefulness of percutaneous management and prognosis in venous rupture during angioplasty of hemodialytic arteriovenous fistulas. Among 814 patients who underwent angioplasty on account of inadequate hemodialysis, 63(39 women and 24 men aged 20-78 (mean, 55.8) years) were included in this study. All 63 had peripheral venous stenosis. Venous rupture was diagnosed when contrast leakage was seen at venography after percutaneous angioplasty (PTA). In order to manage venous rupture, the sites at which this occurred were compressed manually for 3-5 minutes or blood flow was blocked with a balloon catheter for the same period. In one case, a stent was inserted at the rupture site. Using the Kaplan-Meier method, we investigated the patency rate of arteriovenous fistula (AVF) in cases of successful PTA. We also compared PTA patency rates in cases with and without peripheral venous rupture. Venous rupture occurred in 38 cephalic, 16 brachial, and 9 basilic veins. In 63 patients, bleeding stopped and in 54 (85.7 %) of thee, PTA was successful. Among the nine failed cases, dilatation was incomplete in five, though bleeding had stopped. In patients with brachial and cephalic vein rupture the venous tract at the rupture site was not located. Two patients underwent surgery: one of these experienced brachial venous rupture, with incontrollable bleeding, and the other had nerve compression symptoms due to hematoma. Among 54 patients in whom PTA was successful, the primary and secondary six-months rates for angioaccess were 47.9% and 81.2%, and the mean patency period was 6.1 and 15.8 months, respectively. In cases of non-venous rupture, the mean patency period was 9.6 months, significantly longer than in cases involving venous rupture (p=0.02). Venous rupture occurring during the PTA of hemodialytic AVF can be managed percutaneously.

  11. Effect of percutaneous transluminal angioplasty on the stenosis of autogenous radiocephalic ateriovenous fistula for hemodialysis

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Sun Min; Kim, Jeong Ho; Byun, Sung Su; Kang, Jin MMo; Choi, Sang Tae; Kim, Jong Woo; Kim, Hyung Sik; Choi, Hye Young [Gachon University Gil Medical Center, Incheon (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Seonam University College of Medicine, Myongji Hospital, Goyang (Korea, Republic of)

    2016-02-15

    The purpose of this study was to evaluate the effectiveness of percutaneous transluminal angioplasty (PTA) on stenosis of autogenous radiocephalic arteriovenous fistula (RCF) for hemodialysis and to determine the factors influencing patency. This retrospective study included 136 patients referred for PTA of RCF stenosis between March 2005 and July 2014. The technical success rate, complications, and patency rate were evaluated. The following factors were analyzed as they might influence patency: age, gender, site and duration of arteriovenous fistula, underlying disease, body mass index, hypercholesterolemia, smoking, peripheral artery or coronary artery occlusive disease, stenosis length/grade, cutting balloon, and balloon size. The initial technical success rate was 91.9% (125/136). Complications included vessel rupture (n = 2) and vessel dissection (n = 2). The patency rates at 6, 12, 24, and 48 months after PTA were 81.9, 67.1, 52.7, and 42.3%, respectively. The patency rate was higher in cases with longer (> 3 cm) stenosis (p = 0.04). Use of cutting balloon and larger size of balloon catheter made the patency longer, but this difference was not statistically significant (p = 0.637, 0.258). PTA is a safe and effective way to manage stenosis in RCF. The length of stenosis was the only factor which affected the patency rate in this study.

  12. Angioplasty for coarctation in different aged patients.

    Science.gov (United States)

    Walhout, Ronald J; Lekkerkerker, Jaco C; Ernst, Sjef M P G; Hutter, Paul A; Plokker, Thijs H W M; Meijboom, Erik J

    2002-07-01

    Differences in the indication and outcome of balloon angioplasty for coarctation in children and adults have not been elucidated sufficiently. The results of balloon angioplasty for coarctation are compared between pediatric and adult age groups. Balloon angioplasty for coarctation of the aorta was performed in 85 patients who were classified according to age and native coarctation/recoarctation. Groups A (patients aged or =16 years, n = 17) included patients with native coarctations. Groups rCoA A (patients aged or =16 years, n = 3) included patients with recoarctations. Follow-up included 2-dimensional Doppler scanning echocardiography and additional angiography or magnetic resonance imaging. Gradient reductions in groups were compared by use of the independent-samples t test. Kaplan-Meier and log-rank analyses were performed as a means of comparing long-term outcome. No mortality occurred. Immediate success was equal in groups A, B, and rCoA A (94%). Dilatation was unsuccessful in 2 patients in group rCoA B. Pressure gradients decreased 23 mm Hg in group A, 31 mm Hg in group B, 18 mm Hg in group rCoA A, and 11 mm Hg in group rCoA B. Pressure gradient drops, compared between groups A and B, showed a significant difference (P <.001). The length of hospital stay ranged from 12 to 48 hours. The period of follow-up ranged from 6 months to 12 years (mean, 4.9 years). Kaplan-Meier curves of groups A and B are not different, as determined by means of log-rank analysis. No aneurysm formation was encountered. The results of balloon angioplasty for native coarctation in both selected children and adults are excellent. In recoarctation, we recommend balloon angioplasty in the pediatric patients.

  13. Technical note: subclavian artery misplacement of a 12F Shaldon catheter: percutaneous repair with a local closure device under temporary balloon tamponade; Technische Mitteilung: Entfernung eines fehlplatzierten 12F Shaldon Katheters aus der A. subclavia und Abdichtung mittels Verschlusssystem bei temporaerer Ballonblockade

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Katoh, M.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Fussen, R. [Anaesthesiologische Klinik, Medizinisches Zentrum Kreis Aachen GmbH (Germany)

    2006-06-15

    A case of subsequent percutaneous repair using a local closure device with a collagen block (VasoSeal {sup registered}) and temporary balloon tamponade after inadvertent subclavian artery misplacement of a 12F Shaldon catheter is reported. Balloon occlusion safely prevented displacement of collagen into the vascular lumen by occluding the 12F entry site. Furthermore, collagen-induced coagulation was facilitated. (orig.)

  14. Percutaneous transluminal coronary angioplasty for culprit lesions in patients with post myocardial infarction angina based on dextrocardia and anomalous coronary arteries. Case reports and methods.

    Science.gov (United States)

    Yabe, Y; Tsukahara, R

    1995-05-01

    Four cases of successful coronary angioplasty for anomalous coronary arteries, including dextrocardia associated with three-vessel disease, single left coronary artery with proximal left anterior descending lesion, anomalous right coronary artery (RCA) from adjacent left coronary sinus of Valsalva associated with proximal RCA lesion, and anomalous left circumflex angulated lesion bifurcated from the RCA, were encountered. Four cases with 8 target lesions who had a mean age of 63.5 +/- 11.5 years old are presented. All the targets lesions were completely dilated through balloon angioplasty, including use of a newly developed support device for cases with large jeopardized myocardium. The factors for complete revascularization were appropriate selection of catheters and originality and ingenuity of procedural technique based on the anatomic characteristics.

  15. 球囊血管成形术对血浆TNF-α、ET水平及局部血管组织ET-IR的影响%Effect of balloon angioplasty on plasma ET and TNF-α levels and tissue endothe lin immunoreactivity in experimental atherosclerotic rabbits

    Institute of Scientific and Technical Information of China (English)

    杜荣增; 吴宗贵; 黄佐; 黄高忠; 张国元

    2001-01-01

    目的 :通过建立兔髂动脉粥样硬化(AS)模型,观察球囊 血管成形术(BA)对血浆肿瘤坏死因子α(TNF-α)、内皮素(ET)水平及局部血管组织E T免疫反应性(ET-IR)的影响。方法:20只新西兰雄性大白兔经高脂饲 料喂养至少8周造成AS,然后进行髂动脉BA,18只兔获得成功。检测了BA前、即刻及24 h后 血浆ET和TNF-α水平,ET采用放射免疫法测定,TNF-α采用生物活性法测定。同时,应用 免疫组织化学技术评价血管组织ET-IR。结果:BA前后即刻:血浆ET水 平(pg/ml)分别为76.4±13.58和92.67±11.38(P0.05);而血浆TNF-α水平(U/ml)分别为31.35±6.23和56.26±7.37(P 0.05)。 BA后局部髂动脉血管壁ET-IR较未经BA的髂动脉明显增加。结论:BA 后血浆ET、TNF-α水平升高及局部血管壁ET-IR增加可能与局部血管内膜损伤有关,提示E T、TNF-α可能参与了PTCA后急性冠脉收缩及再狭窄过程。%Objective: To assess the effect of balloon angiopl asty on circulating endothelin (ET) and TNF-α levels and tissue endothelin in experimental atherosclerosis in rabbits. Methods: After 20 New Z ealand rabbits had a high cholesterol diet for at least 8 weeks, successful ball oon angioplasty was performed in rihgt iliac arteries in 18 rabbits. Circulatin g levels of ET and TNF-α were measured before as well as immediately and 24 h after balloon angioplasty. Tissue endothelin immunoreactivity in atherosclerotic iliac artery wall after balloon angioplasty was assessed by immunohistochemica l technique. Results: Plasma levels of ET and TNF-α were signi ficantly increased immediately after ballon angioplasty (76.40±13.58)pg/ml vs (92.67±11.38) pg/ml and (31.35±6.23) U/ml vs (56.26±7.37) U/ml, resp ectively (P0.05). T issue endothelin immunoreactiuvity was markedly increased in right iliac artery wall after balloon angioplasty than that in opposite iliac artery wall. Conclusion: The increase of plasma

  16. Laser-driven short-duration heating angioplasty: chronic artery lumen patency and histology in porcine iliac artery

    Science.gov (United States)

    Shimazaki, Natsumi; Kunio, Mie; Naruse, Sho; Arai, Tsunenori; Sakurada, Masami

    2012-02-01

    We proposed a short-duration heating balloon angioplasty. We designed a prototype short-duration heating balloon catheter that can heat artery media to 60-70°C within 15-25 s with a combination of laser-driven heat generation and continuous fluid irrigation in the balloon. The purpose of this study was to investigate chronic artery lumen patency as well as histological alteration of artery wall after the short-duration heating balloon dilatation with porcine healthy iliac artery. The short-term heating balloon dilated sites were angiographically patent in acute (1 hour) and in chronic phases (1 and 4 weeks). One week after the dilatation, smooth muscle cells (SMCs) density in the artery media measured from H&E-stained specimens was approx. 20% lower than that in the reference artery. One and four weeks after the dilatations, normal structure of artery adventitia was maintained without any incidence of thermal injury. Normal lamellar structure of the artery media was also maintained. We found that the localized heating restricted to artery media by the short-duration heating could maintain adventitial function and artery normal structure in chronic phase.

  17. Dose rate in intravascular radionuclide therapy using Re-188 coated balloon

    Energy Technology Data Exchange (ETDEWEB)

    Baek, M. Y.; Kim, J. K. [Hanyang Univ., Seoul (Korea, Republic of)

    2001-05-01

    Restenosis is the major drawback problem after percutaneous transluminal coronary angioplasty (PTCA). In order to reduce the restenosis, radionuclide therapy has been used, and these day balloon coating method with radionuclide is investigating to effective therapy. We intend to calculate the activity by Monte Carlo method, which is needed in the investigation of coated balloon using Re-188. We used EGSnrc code system to calculate this activity. Balloons were assumed be a length of 20 mm or 30 mm and to have a central catheter of diameter 0.5 mm. The surface of balloon is coated with 0.01 mm depth Re-188 using poly urethan. We calculated dose distribution as radial distance from the surface of balloon. And we calculate how much activities are needed to irradiate 18Gy at the 0.5 mm, 1.0 mm distance from balloon surface during 3 minutes. As results it is needed 19.3 mCi and 33.6 mCi relatively for each 0.5 mm and 1.0 mm in the 20 mm balloon. It is need 27.8 mCi and 48.3 mCi in the 30 mm balloon. Recent report for Ho-166 using EGS4 suggests 13.04 mCi at 0.5 mm distance in the 20 mm balloon. This value is lower than our result for Re-188 for the same size balloon. It is considered to be a systemic difference between two simulation codes ({approx}10%)

  18. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  19. 依达拉奉防治大鼠颈动脉球囊成形术后血管再狭窄%Experimental study on edaravone in prevention of restenosis in rat common carotid balloon angioplasty

    Institute of Scientific and Technical Information of China (English)

    周海武; 徐平

    2008-01-01

    Objective To investigate edaravane in prevention of restenosis in rat common catery arteries balloon angioplasty and the possible mechanism of this process. Methods Forty male SD rats were randomly divided into 2 groups: treatment group (whose intima was injured by balloon and was given edaravone 3 mg/kg by peritoneal injection, bid) and control group (whose intima was injured by ballon and was given the same volume NS as edaravone). 1, 3, 7, 14 and 28 days after angioplasty, rats were killed and the local arteries were sectioned for analysis of pathological morphology and the expression of matrix metalloproteinase-2 (MMP-2) analyzed by immunohistochemistry. Results Small amounts of smooth muscle cell appeared at the intima of blood vessel 3 days after the artery injured by balloon. Consecutive intima was formed 7 days after artery injury. The intima was even or uneven thickened and the lumen of artery was significant stenosed 14 and 28 days afterwards. In the control group, the intimal area reached (0.240±0.043) mm2, the intima hyperplasy index were 0.52±0.06, stenosis ratio were 30%±9% 14 days afterwards. The intimal area were (0.420±0.063 )mm2, the intima hyperplasy index were 0.67± 0.07, stenosis ratio were 54%±9% on day 28. In the treatment group, the intimal area were (0.063± 0.025)mm2, the intima hyperplasy index were 0.24±0.07, stenosis ratio were 8%±3% after 14 days. The intimal area were (0.116±0.023) mm2, the intima hyperplasy index were 0.38±0.05, stenosis ratio were 16%±4% after 28 days. Compared with control group at the same time, the intimal area (F values were 50.488 and 81.119 respectively, P < 0.05 ), the intima hyperplasy index ( F values were 41.743 and 48.122 respectively, P<0.05) and stenosis ratio (F values were 24.221 and 81.119 respectively, P< 0.05) were decreased in treatment group. The expressions of MMP-2 raised after balloon injury. In control group, the expressions of MMP-2 were 27.16%±7.15% after 3 days, 22.59%±6

  20. New method of forced implantation of permanent catheters for hemodialysis into critically stenosed or occluded central veins.

    Science.gov (United States)

    Przywara, Stanisław; Iłżecki, Marek; Terlecki, Piotr; Zubilewicz, Tomasz

    2014-12-18

    The aim of the study was to report a novel technique of forced implantation of catheters for hemodialysis into critically stenosed or occluded central veins, without preceding angioplasty or stenting. Sixteen patients with central venous occlusive disease, requiring urgent hemodialysis underwent this procedure. Catheterization of stenosis - occlusion was initially performed with soft guidewire, subsequently exchanged to stiff guidewire. Forced insertion of dilators, peel-off sheath throughout the stenosis or occlusion and finally implantation of the catheter completed the procedure. Our technique does not require pre-procedural angioplasty or stent deployment. In all patients postoperative hemodialysis was managed with satisfactory adequacy. No early or late complications related to the procedure occurred. We did not observe any clinically significant aggravation of symptoms of central vein stenosis or occlusion. Complications, not-related to the procedure included one, late skin entry site infection and one, late catheter thrombosis. These were managed without the necessity of catheter exchange. Our technique of forced implantation of catheters for hemodialysis into critically stenosed or occluded central veins without previous balloon predilatation or stenting is simple and diminishes the total cost of the procedure. Provides quick vascular access for hemodialysis in life threatening situations.

  1. Matrix metalloproteinase inhibition reduces adventitial thickening and collagen accumulation following balloon dilation

    NARCIS (Netherlands)

    Sierevogel, MJ; Velema, E; van der Meer, FJ; Nijhuis, MO; de Kleijn, DPV; Borst, C; Pasterkamp, G

    2002-01-01

    Objective: Constrictive arterial remodeling following balloon angioplasty has been related to adventitial collagen accumulation and subsequent thickening and can be prevented by matrix ructalloprotemase (MMP) inhibition. Following balloon dilation, we examined the effect of MMP inhibition on colla-e

  2. Study on the Effect of Uterine Tamponade Balloon Catheter in the Treatment of Postpartum Hemorrhage%子宫填塞球囊导管治疗产后出血的效果研究

    Institute of Scientific and Technical Information of China (English)

    朱丽秋

    2015-01-01

    目的:研究产后出血应用子宫填塞球囊导管治疗的临床疗效。方法选取我院2013年6月~2014年6月间收治的产后出血患者49例,研究组采取子宫填塞球囊导管治疗,对照组采取子宫腔纱布填塞法治疗,对比两组治疗效果。结果研究组治疗时间与操作时间相对较短,预后良好,两组治疗效果差异显著,有统计学意义(P<0.05)。结论产后出血应用子宫填塞球囊导管治疗操作简便、出血量少、效果良好。%Objective Clinical effect of uterine tamponade balloon catheter in treatment of postpartum hemorrhage is to be studied.MethodsChoose 49 patients of postpartum hemorrhage who are treated in hospital from June 2013 to June 2014 and separate them into two groups, patients in study group are given uterine tamponade balloon catheter treatment and patients in control group are given intrauterine gauze packing treatment and then compare treatment effects between two groups.Results Compared to control group, patients’ treatment time and treatment operation time in study group are relatively shorter with much more favorable prognosis, there is a treatment differential between two groups and such a differential has statistic value (P<0.05). Conclusion Uterine tamponade balloon catheter is easy to operate in treatment of postpartum hemorrhage and it is conducive to reducing hemorrhage with favorable effect.

  3. Successful tunneled catheter placement in a hemodialysis patient with idiopathic multiple central venous stenoses.

    Science.gov (United States)

    Zhao, Yuliang; Cui, Tianlei; Yu, Yang; Liu, Fang; Fu, Ping; Zhou, Li; Li, Xiao

    2014-01-01

    Central venous stenosis (CVS) in hemodialysis patients could be secondary to central venous catheterization, high flow arteriovenous fistula, as well as extrinsic compression. However, we report a senile hemodialysis patient of left internal jugular vein stenosis and right innominate vein occlusion unrelated to any known risk factors. Aided by computed tomography and digital subtraction angiography, we managed to dilate the stenosis by percutaneous balloon angioplasty, followed by successful tunneled catheter placement. Nephrologists should be aware of idiopathic CVS and its impact on the creation and preservation of vascular access. When confronted with difficulties in catheter placement, practitioners need to consider the possibilities of idiopathic CVS and refer to radiological tests. © 2013 International Society for Hemodialysis.

  4. Clinical analysis of double-balloon catheter for cervical ripening in 66 cases%促子宫颈成熟球囊改善子宫颈条件66例临床观察

    Institute of Scientific and Technical Information of China (English)

    赫英东; 胡君; 章小维; 黄禾; 陈倩

    2014-01-01

    Objective To evaluate the efficacy and safety for cervical ripening by double-balloon catheter among full-term pregnancy women underwent labor induction.Methods It was a prospective nonrandomly controlled research.Totally 128 singleton-pregnancy women in full-term who had to undergo labor induction because of pregnancy complications or comorbidities from August 2011 to April 2013 in Peking University First Hospital were selected as study subjects.Participants were allocated to preinduction cervical ripening with either a double-balloon catheter (66 participants,study group) or prostaglandin vaginal insert (62 participants,control group).Compare the efficacy for cervical ripening and adverse reactions between the two groups.Results The efficacy for cervical ripening (Bishop scores improved by ≥ 2) had no significant differences between study and control groups [82% (54/66) compared with 81% (50/ 62),P>0.05].The time interval between intervention and parturiency was significantly higher in the doubleballoon catheter group than in the prostaglandin vaginal insert group [(24.2±8.5) compared with (14.5±8.0) hours,P<0.05].The proportion of women who achieved parturiency within 12 hours was significantly lower in the double-balloon catheter group than that in the control group [9% (6/66) compared with 21% (13/62),P<0.05].The cesarean section rate showed no significant differences [41% (27/66) compared with 43%(27/62),P>0.05].The prevalence of intrauterine infection demonstrated by clinical diagnosis was significantly higher in the double-balloon catheter group [11% (7/66) compared with 6% (4/62),P<O.05].The double-balloon catheter group had significantly lower rates of contraction overfrequency [0(0/66) compared with 42% (26/62),P<0.05],hyperthermia [3% (2/66) compared with 19% (12/62),P<0.05],fetal heart rate abnormalities before removing the device or drug [5% (3/66) compared with 19% (12/62),P<0.05],as well as precipitate

  5. Role of endovascular irradiation in the prevention of vascular restenosis following angioplasty; Role de la curietherapie endovasculaire dans la prevention de la restenose vasculaire apres angioplastie

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.; Feuvret, L.; Mazeron, J.J.; Pousset, F. [Hopital Pitie-Salpetriere, 75 - Paris (France); Bourhis, J.; Gerbaulet, A. [Institut Gustave Roussy, 94 - Villejuif (France); Popowski, Y. [Hopital Universitaire, Geneve (Switzerland)

    1998-07-01

    About 30% of patients who underwent percutaneous transluminal coronary angioplasty show evidence of restenosis, which appears to be independent of the angioplasty method used. The restenosis is due of two factors, Firstly migration of smooth vascular muscle cells of the vascular media to the intima and multiplication which lead to the formation of a neo-intima. Irradiation limits the proliferation by acting of the cells in the mitotic stage. The vascular target volume is not very thick and is difficult to define it, that why brachytherapy seems to be the best procedure to prevent restenosis. However, the development of this treatment present many difficulties. Different irradiation techniques have been studied. Such techniques include catheter containing radioactive sealed source, radioactive stent, or balloon containing radioactive liquid inside. Each of these methods have their own advantages, inconveniences, problems and risks. Radioisotope may be either beta or gamma emitters.Gamma emitter presents problems for radioprotection but the satisfactory dose distribution may be difficult to obtain using beta emitter. Choice of dose, dose rate and delay between the end of angioplasty and the beginning of brachytherapy is subject to some discuss. Animal experiments using radioisotope have shown reduction in cell proliferation. Human trials showed feasibility, safety of the method and real impact on restenosis prevention. However, long-term efficacy has not been proved because the follow-up of the patients is too short. A randomized trial of {sup 192}Ir brachytherapy for prevention of restenosis has recently shown the efficacy in short and median term. However, long term efficiency and secondary effects have not yet been established as the follow up time of this study is still too short. That is why, collaboration between cardiologists and radiotherapists and physicists is indispensable to enable the development of an optimal technique. (authors)

  6. Histopathology of human laser thermal angioplasty recanalization.

    Science.gov (United States)

    White, R A; White, G H; Vlasak, J; Fujitani, R; Kopchok, G E

    1988-01-01

    Laserprobe thermal-assisted balloon, angioplasty (LTBA) has demonstrated promising initial clinical results in recanalizing stenotic or occluded superficial femoral and popliteal arteries. Over the past year we have obtained six specimens of laserprobe thermal (LT) and LTBA treated total occlusions (avg. length 12 cm) for histopathologic examination from patients who were treated for limb salvage. Three tissue specimens were obtained acutely, and one was obtained at 6, 8, and 13 days, respectively, after laser angioplasty at the time of revision for complications or failed procedures. Serial histologic sections of the treated LT segments demonstrated recanalization of atherosclerotic lesions to approximately 60-70% of the probe diameter. The LT channels were lined by a thin layer of carbonized or coagulated tissue and several layers of cell necrosis. The histology of the thermal injury was similar regardless of whether it was produced by the heated metal cap or by free argon laser energy. Stellate balloon angioplasty fractures were frequently filled with thrombus. Analysis of these human LT and LTBA specimens revealed that the thermal device produces a confined injury through the path of least resistance. Balloon dilatation produces fragmented cracks in the vessel wall, which appear to be more thrombogenic than the carbonized LT surface. With improved guidance methods, LTBA shows potential for continuing development.

  7. 子宫填塞球囊导管治疗产后出血10例临床分析%Clinical treatment analysis of uterine tamponade balloon catheter on 10 cases of postpartum hemorrhage

    Institute of Scientific and Technical Information of China (English)

    韩静; 秦永丽

    2014-01-01

    目的:评价子宫填塞球囊导管对治疗产后出血,挽救产妇生命,保留子宫的影响。方法:2013年3-8月收治产后出血患者10例,并完善随访的临床资料及产后康复追踪。结果:10例产后出血治疗成功率100%,无一例子宫切除。结论:子宫球囊填塞是宫缩乏力继发重度产后出血的有效辅助治疗措施,尤其当药物治疗失败时更显其价值。%Objective:To explore the effect of uterine tamponade balloon catheter in the treatment of postpartum hemorrhage, rescuing maternal life,retaining uterine.Methods:10 cases with postpartum hemorrhage were selected from March to August 2013. Follow-up clinical data were completed and postpartum rehabilitation was traced.Results:The treatment success rate of 10 cases of postpartum hemorrhage was 100%.No case was hysterectomy. Conclusion: Uterine tamponade balloon catheter is secondary effective auxiliary treatment for severe postpartum hemorrhage caused by uterine inertia, especially show its value when drug treatment is failure.

  8. Postoperative effects of sinus balloon catheter dilation on chronic rhinosinusitis:A meta-analysis%慢性鼻-鼻窦炎患者鼻窦球囊扩张术后疗效的Meta分析

    Institute of Scientific and Technical Information of China (English)

    于青青; 王跃建; 唐隽

    2016-01-01

    ABSTRACT]OBJECTIVEThis meta-analysis aims to evaluate the postoperative effects of sinus balloon catheter dilation on chronic rhinosinusitis.METHODS Pubmed, EMBASE, MEDLINE, CNKI, Wanfang Data, CBM and VIP were searched for before-after self-controlled trials about the postoperative effects of sinus balloon catheter dilation on chronic rhinosinusitis from the date of establishment of the databases to April of 2015. The extracted data were analyzed by Revman 5.0.RESULTS A total of 8 studies were included. Meta-analysis showed the SNOT-20 scores at 3, 6, 12 months after operation, the Lund-Kennedy and VAS scores at 3 months after operation and the Lund-Mackay scores at 1 year after operation of the patients with chronic rhinosinusitis were significant lower than those before operation(P<0.05).CONCLUSION The postoperative effect of sinus balloon catheter dilation on chronic rhinosinusitis is obvious. Sinus balloon catheter dilation has a good application prospect in the treatment of chronic rhinosinusitis.%目的:旨在评价鼻窦球囊扩张术(sinus balloon catheter dilation,SBCD)对慢性鼻-鼻窦炎(CRS)患者的临床疗效。方法计算机检索Pubmed、EMBASE、MEDLINE、中国知网、万方数据库、中国生物医学文献数据库和维普数据库中关于CRS患者SBCD后疗效的自身前后对照试验,时限为从建库到2015年4月。对纳入研究的质量进行严格评价与提取资料,对符合标准的文献进行系统评价,统计学分析应用RevMan 5.0软件。结果共纳入8篇自身前后对照试验。结果显示CRS患者SBCD后3个月、6个月及1年的SNOT-20评分,术后3个月的Lund-Kennedy评分与VAS评分,以及术后1年的Lund-Mackay评分均低于术前,其差异均有统计学意义(P<0.05)。结论 CRS患者行SBCD后恢复快,并发症减少,SBCD在CRS的治疗中具有较好的应用前景。

  9. Dilatação por cateter-balão (dacrioplastia para tratamento das obstruções congênitas do ducto lacrimonasal Balloon-catheter dilatation (dacrioplasty for congenital nasolacrimal duct obstruction treatment

    Directory of Open Access Journals (Sweden)

    Roberto Murillo Limongi de Souza Carvalho

    2009-10-01

    Full Text Available OBJETIVO: Verificar o resultado da técnica, inédita no Brasil, de dilatação do ducto lacrimonasal usando cateter-balão para tratamento da obstrução congênita do ducto lacrimonasal. MÉTODOS: Foram tratadas crianças com idade entre dois e cinco anos, com obstrução congênita de vias lacrimais usando o cateter-balão (Lacricath® para dilatação das vias lacrimais. O cateter foi introduzido pelo ponto lacrimal superior, sob anestesia geral. RESULTADOS: Entre os 27 olhos tratados, 23 apresentaram desaparecimento dos sinais e sintomas de lacrimejamento (taxa de sucesso de 85,2%. Todos os procedimentos foram realizados sem intercorrências e o seguimento pós-operatório mínimo foi de um ano. CONCLUSÃO: A dilatação com balão mostrou-se segura e eficiente como primeiro procedimento para os casos de obstrução congênita das vias lacrimais em crianças com mais de dois anos.Purpose: To verify the results of balloon-catheter dilatation for the treatment of congenital lacrimal duct obstruction. To the best of author's knowledge this procedure has not been previously used in Brazil and deserves scientific studies. METHODS: Children between 2 and 5 years old, with congenital lacrimal duct obstruction, were treated with balloon-catheter dilatation (Lacricath®. Catheter was introduced by the superior lacrimal punctum, under general anesthesia. RESULTS: Twenty-seven eyes were treated and 23 presented total improvement of epiphora signs and symptoms (85.2% success rate. During a one year follow-up, all the procedures had good outcomes, without complications and all the children had 1 year of follow-up. CONCLUSION: Balloon-catheter dilatation is an efficient and safe procedure and might be used for congenital lacrimal duct obstruction treatment in children older than 2 years.

  10. Application of uterine tamponade with balloon catheter for treatment of postpartum hemorrhage%应用子宫填塞球囊导管治疗产后出血的初步经验

    Institute of Scientific and Technical Information of China (English)

    阮颖清

    2012-01-01

    Objective To investigate the efficacy and safety of uterine tamponade with balloon catheter for the treatment of postpartum hemorrhage.Methods The data on 24 patients with postpartum hemorrhage who had received uterine tamponade with balloon catheter during the period of January 2010 to February 2012 were retrospectively analyzed.The average age of the patients was 27.5 years old ( 22-34 ).Of the 24 patients,12 had uterine inertia,4 had placenta previa,and 8 had placenta accrete.Results All the patients were cured by uterine tamponade with balloon catheter,and no one needed to undergo hysterectomy.The primary effectiveness rate of hemostasis was 91.6%.Two patients had rebleeding,and the tamponade balloon was inflated again to stop bleeding.The tamponade balloon was removed after 24 hours.None had rebleeding,nor hysterectomy needed.The total effectiveness rate of hemostasis was 100%.No patients required hysterectomy or were dead.All the patients were followed up for 1 to 24 months postoperatively and had a normal uterine involution and menstrual restoration within 1 to 3 months.No puerperal infection or symptoms of premature ovarian failure occurred.Conclusions Application of uterine tamponade with balloon catheter in the treatment of postpartum hemorrhage is safe,effective,and worth popularizing clinically.%目的 探讨应用子宫填塞球囊导管治疗产后出血的疗效及安全性.方法 对我院2010年1月-2012年2月,24例使用子宫填塞球囊导管治疗产后出血患者进行回顾性分析.患者年龄22~34岁,平均27.5岁,其中产后出血病因宫缩乏力12例、前置胎盘4例,胎盘粘连8例.结果 全部病例均能应用子宫填塞球囊导管达到止血目的,无一例行子宫切除术.一次止血有效率达91.6%.2例患者出现再发出血,再次充盈气囊止血后,两例患者于24小时再尝试取出水囊,未再发大出血,总止血有效率达100%.无一例需行子宫切除术或死亡,术后随访1~24

  11. Provisional stenting in the real world: results in 1058 consecutive patients undergoing percutaneous coronary angioplasty.

    Science.gov (United States)

    Ten Berg, Jurriën M; Kelder, Johannes C; Suttorp, Maarten Jan; Plokker, Thijs HW

    2001-09-01

    OBJECTIVE: To study a strategy of aggressive coronary balloon angioplasty with provisional stenting in allcomers. In randomized trials, stenting has improved the outcome of patients undergoing coronary intervention. However, whether these results hold up in clinical practice is largely unknown. Furthermore, the results of balloon angioplasty have also improved dramatically. It is therefore essential to evaluate the current results of balloon angioplasty and to assess whether stents are required in all patients. METHODS: The authors prospectively studied the occurrence of death, myocardial infarction (MI) and target lesion revascularization (TLR) of a large consecutive group of patients undergoing aggressive balloon angioplasty with provisional stenting. None of the patients received a platelet glycoprotein IIb/IIIa receptor blocker. The results were compared with the outcome of routine stenting in recent randomized trials. RESULTS: Angioplasty was performed in 1058 patients of whom 369 (34.9%) received a stent. The angiographic success rate was 98.9%. During hospital stay, 4.8% of the patients suffered any cardiac event. At one-year follow-up, death occurred in 1.1%, MI in 3.3%, TLR in 12.4% and any event in 16.7% of the patients. Event-free survival at one-year was 82.3%. These results compare favorably with routine stenting in recent trials. CONCLUSIONS: Aggressive balloon angioplasty with provisional stenting yields excellent results in a general patient population.

  12. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio [Montevergine Clinic, Mercogliano (Italy); Golino, Luca, E-mail: lucagolino.jazz@alice.it [Montevergine Clinic, Mercogliano (Italy); Moriggia-Pelascini Hospital, Gravedona, Como (Italy); Casafina, Alfredo; Schiano, Vittorio [Montevergine Clinic, Mercogliano (Italy); Gabrielli, Gabriele [University Hospital Ospedali Riuniti, Ancona (Italy); Ettori, Federica; Chizzola, Giuliano [Spedali Civili University Hospital, Brescia (Italy); Bernardi, Guglielmo; Spedicato, Leonardo [University Hospital S. Maria Misericordia, Udine (Italy); Armigliato, Pietro [Istituto Italiano Ricerche Mediche, Verona (Italy); Spampanato, Carmine [Telethon Institute of Genetics and Medicine (TIGEM), Naples (Italy); Furegato, Martina [Istituto Italiano Ricerche Mediche, Verona (Italy)

    2015-04-15

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  13. Safety and efficacy of recombinant Hirudin (CGP 39 393) versus Heparin in patients with stable angina undergoing coronary angioplasty

    NARCIS (Netherlands)

    A.A. van den Bos (Arjan); G.R. Heyndrickx (Guy); G-J. Laarman (GertJan); H. Suryapranata (Harry); F. Zijlstra (Felix); P. Close (Philip); J.J.M.M. Rijnierse (Joep); H.R. Büller (Harry); P.W.J.C. Serruys (Patrick); J.W. Deckers (Jaap)

    1993-01-01

    textabstractBACKGROUND. Enhanced thrombin activity has been associated with acute and long-term complications following balloon angioplasty (percutaneous transluminal coronary angioplasty (PTCA). We evaluated, in a 2-to-1 randomized, double-blind trial, the effects of recombinant hirudin, CGP 39 393

  14. Application of Bakri uterine tamponade with balloon catheter in treatment of postpartum hemorrhage%Bakri子宫填塞球囊导管在治疗产后出血中的应用

    Institute of Scientific and Technical Information of China (English)

    崔金晖; 李玲; 陈新娟; 李萍; 范建辉

    2014-01-01

    Objective To evaluate the therapeutic efficacy of Bakri uterine tamponade with balloon catheter in the treatment of postpartum hemorrhage and summarize the application experience. Methods Clin-ical data of 64 patients with postpartum hemorrhage undergoing Bakri uterine tamponade with balloon catheter were retrospectively analyzed. Clinical characteristics were summarized to evaluate clinical effect of Bakri uter-ine tamponade with balloon catheter in the treatment of postpartum hemorrhage and application experience was accumulated. Cases of bleeding reduction without the requirement of undergoing any other treatment were de-fined as successful treatment. Results Sixty-four patients were enrolled in this study. The causes of postpar-tum hemorrhage included uterine inertia,hemorrhage from the stripping surface of placenta and placenta im-plantation. The success rate of postpartum hemorrhage treatment was 94%. Among four patients with treatment failure,three had placenta implantation. Conclusions Application of Bakri uterine tamponade with balloon catheter is a simple procedure,which can observe the quantity of bleeding in a real-time manner,effectively treat postpartum hemorrhage and reduce the amount of hemorrhage. Placenta implantation may be one of rea-sons resulting in treatment failure.%目的:探讨Bakri子宫填塞球囊导管对产后出血的治疗效果,总结应用经验。方法对64例分娩发生产后出血、应用Bakri子宫填塞球囊导管治疗的患者进行回顾性病例分析,总结患者临床特点,分析Bakri子宫填塞球囊导管对产后出血的治疗效果,总结应用经验。将放置Bakri子宫填塞球囊导管后出血减少,无需采取其他治疗措施者定义为治疗成功。结果研究期间应用Bakri子宫填塞球囊导管患者共64例,产后出血原因主要为子宫收缩乏力、胎盘剥离面出血、胎盘植入, Bakri子宫填塞球囊导管治疗产后出血成功60例,成功率为94%,4

  15. Pumpkin Balloon

    OpenAIRE

    Nishimura, Jun; 西村, 純

    1992-01-01

    The Pumpkin shaped balloons, which are the extreme case of the heart-type balloons had been studied as one of the promising candidate of the super pressure balloons. Here, detailed studies for the features of the pumpkin balloons are described, particularly by comparing with those of the spherical shaped super pressure balloons.

  16. Efeito da L-arginina na neoproliferação intimal e no remodelamento arterial após lesão por balão, em ilíacas de coelhos hipercolesterolêmicos The effect of L-arginine on neointimal proliferation and artery remodeling on an iliac artery lesion caused by a balloon catheter in hypercholesterolemic rabbits

    Directory of Open Access Journals (Sweden)

    José Knopfholz

    2006-10-01

    Full Text Available OBJETIVO: A neoproliferação intimal e o remodelamento têm sido implicados como os maiores fatores causadores de reestenose. O objetivo deste trabalho é estudar a ação da L-arginina por via oral, nesses dois fatores, após lesão por balão, em artérias ilíacas de coelhos hipercolesterolêmicos. MÉTODOS: Foram utilizados dezenove coelhos, que foram divididos em dois grupos: controle (GC e arginina (GA, respectivamente com dezenove e dezessete artérias estudadas. Os animais foram submetidos a lesão por balão de angioplastia, em suas artérias ilíacas, quinze dias após início de dieta hipercolesterolêmica a 2%. A seguir, os animais do GA passaram a receber uma solução de L-arginina, por via oral, na dose de 1 g/kg/dia. Após o sacrifício, no 15º dia após a lesão por balão, procedeu-se a cortes histológicos das artérias, as quais foram coradas e fixadas. Utilizou-se como representativa do desenvolvimento da lesão a razão da área da neoíntima (em mm² pela camada média (em mm². Por sua vez, a razão da área total do vaso em sua porção medial (de maior contato com o balão pela área total do vaso no segmento referencial (de menor contato com o balão foi a definidora do remodelamento. RESULTADOS: A média do espessamento neointimal (NI/M foi de 0,8151±0,2201 no GC e de 0,3296±0,1133 no GA. Não houve diferença entre os tipos de remodelamento entre os dois grupos estudados. CONCLUSÃO: No modelo experimental utilizado, a L-arginina foi capaz de reduzir o espessamento intimal em coelhos hipercolesterolêmicos e não teve ação sobre o remodelamento arterial.OBJECTIVE: It has been implied that neointimal proliferation and remodeling are the major causes of restenosis. The objective of this study is to assess the effect of orally administered L-arginine on these two factors in hypercholesterolemic rabbits that had suffered an injury to their iliac arteries caused by a catheter balloon. METHODS: The study included

  17. [Role of angioplasty in the treatment of renal artery stenosis].

    Science.gov (United States)

    Armero, S; Bonello, L; Paganelli, F; Barragan, P; Roquebert, P-O; Commeau, P

    2011-12-01

    Atherosclerotic renal artery stenosis is frequent and is associated with a high incidence of morbidity and mortality, with a strong correlation with coronary artery disease, (Kalra et al., 2005; Cheung et al., 2002; Guo et al., 2007 [1-3]). The atherosclerotic renal artery stenosis is an independent predictive factor of death (Conlon et al., 1998 [4]). The treatment of this lesion does not have strong evidence. A lot of studies in this area suggest the angioplasty is superior in a big majority between surgery, and angioplasty with stent is superior between balloon angioplasty, but some studies fail to prove the superiority of angioplasty versus medical treatment. These studies have sadly a lot of mistakes and nowadays we don't know what is the treatment for our patients in a lot of cases. The angioplasty is indicated when there is a failure of antihypertensive medications for control of blood pressure, when it is associated with a renal insufficiency quickly progressive or when there is a lesion on each renal artery. Other studies must be organized for prove the superiority of angioplasty when there is a real stenosis, maybe with the use of fractional flow reserve.

  18. Femoro-popliteal artery occlusions treated by percutaneous transluminal angioplasty and enclosed thrombolysis

    DEFF Research Database (Denmark)

    Tønnesen, K H; Holstein, P; Andersen, E

    1991-01-01

    Removal of fibrin from the site of a newly dilated femoro-popliteal occlusion may be an attractive way of preventing rethrombosis. A double balloon catheter with a dilating tip balloon and an occlusive balloon 10, 15 or 20 cm approximately were introduced percutaneously. Following successful dila...

  19. Angioplasty and Vascular Stenting

    Science.gov (United States)

    ... flow in the graft or fistula making it inadequate for dialysis, angioplasty is generally the first line ... inform your doctor about recent illnesses or other medical conditions. Women ... does the equipment look like? In these procedures, x-ray imaging ...

  20. Subintimal angioplasty for femoro-popliteal occlusive disease.

    Science.gov (United States)

    Markose, George; Miller, Fiona N A C; Bolia, Amman

    2010-11-01

    There has been a longstanding debate about the roles of surgical bypass graft, percutaneous transluminal angioplasty, subintimal angioplasty, and conservative management for femoro-popliteal occlusive disease. Subintimal angioplasty was first described in 1987 as a method of performing an endovascular arterial bypass. The subintimal space at the start of the occlusion is entered with a catheter and a wire loop is used to cross the occlusion and reenter the vessel lumen distally. In patients with critical limb ischemia, there is high quality evidence demonstrating that the limb salvage rate and amputation-free survival rates for surgery and endovascular treatment are similar, but surgery is more expensive than angioplasty in the short term. In patients with intermittent claudication, surgical bypass using an autologous saphenous vein graft is currently believed to be the gold standard, but this is increasingly questioned in the light of recent advances in endovascular techniques. Surgical bypass with vein graft offers a 2-year patency of 81%, compared with 67% for a polytetrafluoroethylene (PTFE) graft and at best 67% for subintimal angioplasty. The better patency offered by surgery must be balanced against a higher morbidity and mortality. To conclude, subintimal angioplasty is an extremely valuable technique in the management of critical limb ischemia. Based on the evidence to date, this technique is likely to have an increasing role in the management of intermittent claudication over the coming years, particularly if the risk of general anaesthesia is high or there is no suitable vein.

  1. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent [Baskent University, Adana Teaching and Medical Research Centre, Department of Radiology, Adana (Turkey)]. E-mail: loguzkurt@yahoo.com; Tercan, Fahri [Baskent University, Adana Teaching and Medical Research Centre, Department of Radiology, Adana (Turkey); Yildirim, Sedat [Baskent University, Adana Teaching and Medical Research Centre, Department of Surgery, Adana (Turkey); Torun, Dilek [Baskent University, Adana Teaching and Medical Research Centre, Department of Nephrology, Adana (Turkey)

    2005-08-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  2. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  3. Percutaneous transluminal coronary angioplasty in refractory unstable angina pectoris: are new devices useful?

    Science.gov (United States)

    Bertaglia, E; Ramondo, A; Cacciavillani, L; Isabella, G; Reimers, B; Marzari, A; Maddalena, F; Chioin, R

    1996-11-15

    This study was undertaken to assess if the introduction of new angioplasty devices (autoperfusion balloon catheters, stent and atherectomy) could ameliorate early and late results of prompt percutaneous transluminal coronary angioplasty (PTCA) in patients with refractory unstable angina. From January 1993 to June 1995, 59 of 278 patients (14 female, 45 male; mean age: 61 +/- 10 years; range: 38-78) admitted to our Coronary Care Unit with the diagnosis of unstable angina had more than one episode of chest pain at rest with dynamic electrocardiographic ST-T changes and without signs of cardiac necrosis while on medical therapy including oxygen, aspirin, heparin, nitroglycerin and either a beta-blocker or a calcium-antagonist. Coronary angiography was performed within 48 h from the last ischemic attack and a culprilesion technically suitable for PTCA was identified. PTCA was performed in 73 lesions. Elective stent implantation was considered for 16 type B or C lesions in 14 patients. The procedure was initially successful in 52/59 patients (88%), uncomplicated unsuccessful in 4/59 (7%) and complicated in 3/59 (5%). Elective stent insertions were all successful (16/16, 100%). All successfully treated patients were followed up for a mean of 12 +/- 7 months (range: 6-27): 2/52 patients (3.8%) suffered from non-transmural myocardial infarction, 14/52 (26.9%) had a recurrence of angina and 2/52 (3.8%), asymptomatic, had a positive stress test. We conclude that prompt PTCA in refractory unstable angina using 1990s 'state of the art' equipment compares favorably to previous study and that stent delivery might become the elective treatment of complex lesions in this subset of patients.

  4. A Finite Difference Numerical Analysis of Heat Transfer in Atheromatous Plaque for Percutaneous Transluminal Microwave Angioplasty

    Science.gov (United States)

    1990-06-01

    method for placing a catheter into the vascular system by surgical exposure of a blood vessel or percutaneous technique was developed by S.I. Seldinger ...angioplasty method is a new technique that has a tremendous potential for selectively heating atheromatous plaques in arteries with minimal thermal...well as reduced medical expenses associated with this procedure. Modern angioplasty techniques are the by-products of two important technological

  5. DNA aptamer raised against advanced glycation end products inhibits neointimal hyperplasia in balloon-injured rat carotid arteries.

    Science.gov (United States)

    Ojima, Ayako; Oda, Eriko; Higashimoto, Yuichiro; Matsui, Takanori; Yamagishi, Sho-ichi

    2014-02-15

    Advanced glycation end products (AGE) and their receptor (RAGE) interaction elicit inflammatory and proliferative reactions in arteries, thus playing a role in cardiovascular disease. We have recently found that high-affinity DNA aptamer directed against AGE (AGE-aptamer) prevents the progression of experimental diabetic nephropathy by blocking the harmful actions of AGEs in the kidney. However, effects of AGE-aptamer on vascular injury remain unknown. In this study, we examined whether and how AGE-aptamer inhibits neointimal hyperplasia in balloon-injured rat carotid arteries. Male Wistar rats (weighting ca. 400 g at 11 weeks old) were anesthetized with sodium pentobarbital. The left common carotid artery was balloon-injured 3 times with 2F Fogaty catheter inserted through the femoral artery. Then the rats received continuous intraperitoneal infusion (3 μg/day) of either AGE-aptamer or control-aptamer by an osmotic mini pump for 2 weeks. 14 days after the procedure, the left common carotid arteries were excised for morphometric, immunohistochemical and western blot analyses. Compared with control-aptamer, AGE-aptamer significantly suppressed neointima formation after balloon injury and reduced AGE accumulation, oxidative stress generation, proliferation cell nuclear antigen-positive area, macrophage infiltration, RAGE and platelet-derived growth factor-BB (PDGF-BB) expression levels in balloon-injured carotid arteries. The present study suggests that AGE-aptamer could prevent balloon injury-induced neointimal hyperplasia by reducing PDGF-BB and macrophage infiltration via suppression of the AGE-RAGE-mediated oxidative stress generation. AGE-aptamer might be a novel therapeutic strategy for suppressing neointima formation after balloon angioplasty. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Intracoronary {beta}-brachytherapy using a rhenium-188 filled balloon catheter in restenotic lesions of native coronary arteries and venous bypass grafts

    Energy Technology Data Exchange (ETDEWEB)

    Woehrle, Jochen; Nusser, Thorsten; Habig, Thomas; Kochs, Matthias; Hombach, Vinzenz [University of Ulm, Department of Internal Medicine II (Germany); Krause, Bernd J.; Mottaghy, Felix M.; Reske, Sven N. [University of Ulm, Department of Nuclear Medicine (Germany); Kotzerke, Joerg [University of Dresden, Department of Nuclear Medicine (Germany); Hoeher, Martin [Klinikum Bayreuth, Department of Internal Medicine II (Germany)

    2006-11-15

    We have previously demonstrated the efficacy of intracoronary {beta}-brachytherapy using a liquid{sup 188}Re-filled balloon in a randomised trial including de novo lesions. Percutaneous coronary interventions in restenotic lesions and in stenoses of venous bypass grafts are characterised by a high recurrence rate for restenosis and re-interventions. Against this background, we wanted to assess the impact of intracoronary {beta}-brachytherapy using a liquid{sup 188}Re-filled balloon in restenotic lesions in native coronary arteries and venous bypass grafts. In 243 patients, {beta}-brachytherapy with 22.5 Gy was applied at a tissue depth of 0.5 mm. Patients were followed up angiographically after 6 months and clinically for 12 months. The primary clinical endpoint was the incidence of MACE (death, myocardial infarction, target vessel revascularisation). Secondary angiographic endpoints were late loss and binary restenosis rate in the total segment. All irradiation procedures were successfully performed. A total of 222 lesions were in native coronary arteries; 21 were bypass lesions. Mean irradiation length was 41.6{+-}17.3 mm (range 20-150 mm) in native coronary arteries and 48.1{+-}33.9 mm (range 30-180 mm) in bypass lesions; the reference diameter was 2.57{+-}0.52 mm and 2.83{+-}0.76 mm, respectively. There was no vessel thrombosis during antiplatelet therapy. Angiographic/clinical follow-up rate was 84%/100%. MACE rate was 17.6% in the native coronary artery group and 38.1% in the CABG group (p<0.03). Binary restenosis rate was 22.5% and 55.6% (p<0.01), and late loss was 0.38{+-}0.72 mm and 1.33{+-}1.11 mm (p<0.001), respectively. We conclude that intracoronary {beta}-brachytherapy with a liquid{sup 188}Re-filled balloon using 22.5 Gy at a tissue depth of 0.5 mm in restenotic lesions is safe. It is associated with a low binary restenosis rate, resulting in a low occurrence rate of MACE within 12 months in restenotic lesions in native coronary arteries but not in

  7. 可注射珊瑚人工骨与经皮球囊成型修复股骨头坏死%Percutaneous balloon angioplasty combined with injectable coral artificial bone repairs femoral head necrosis

    Institute of Scientific and Technical Information of China (English)

    朱康华; 孟志斌; 黄涛; 谭海涛; 孙博; 庞学毅

    2016-01-01

    BACKGROUND: There are many methods for the treatment of femoral head necrosis, such as core decompression, bone graft, arthroplasty and joint replacement, and each of which has its own shortcomings. So, percutaneous bal oon angioplasty combined with coral artificial bone provides a new attempt for the treatment of femoral head necrosis. OBJECTIVE: To observe the effect of percutaneous bal oon angioplasty combined with coral artificial bone on femoral head necrosis repair. METHODS: Twenty-four Duroc piglets were enrol ed to establish bilateral femoral head necrosis models by liquid nitrogen freezing method. Then, model piglets were randomly treated with percutaneous bal oon angioplasty combined with injectable coral artificial bone (experimental group) or bone cement (control group) on one affected side, and meanwhile, given no treatment on the contralateral side (blank control group). At 2, 4, 8 and 16 weeks after surgery, X-ray examination, biomechanical test and histological detection were conducted. RESULTS AND CONCLUSION: X-ray showed that at 16 weeks after surgery, numerous new bones could be found in the experimental group and there was a fuzzy boundary between the artificial bone and surrounding tissues; no new bone formed in the control group, and the boundary was clear; in the blank control group, the surface of the femoral head col apsed, and bone trabeculae arranged disorderly, which were seriously destroyed. And in the histological detection at 16 weeks after surgery, there were numerous bone trabecula and osteoblasts around the coral bone in the experimental group, and the coral artificial bone almost dissolved; in the control group, bone cement was in an irregular shape and no bone trabecula formed; in the blank control group, bone trabecula were damaged in the col apsed area, whose structure was in disorder. Additional y, biomechanical changes in the experimental group were significantly better than those in the other two groups at different time

  8. Percutaneous transluminal angioplasty of a non-mainstream venous route to restore an occluded hemodialysis fistula.

    Science.gov (United States)

    Miyayama, Shiro; Yamashiro, Masashi; Ikuno, Masaya; Okumura, Kenichiro; Yoshida, Miki; Kato, Tamayo; Ushiogi, Yasuyuki

    2014-02-01

    To report the usefulness of percutaneous transluminal angioplasty (PTA) of a non-mainstream venous route in an occluded native hemodialysis fistula when a mainstream outflow vein could not be traversed. This cohort included seven patients with an occulted hemodialysis fistula with difficulty in traversing via a mainstream route. A non-mainstream vein near the occluded portion was traversed until it connected with a proximal large-sized vein and the route was dilated using a 4- or 5-mm balloon catheter. Metallic stent placement was performed, if necessary. Technical aspects and long-term patency was evaluated. PTA could be performed in all patients; however, stent placement was required in two because of residual stenosis and clotting. The clinical success rate of fistula restoration was 100 %. Fistula dysfunction recurred in six patients 17-668 days (mean ± standard deviation 229.3 ± 225.0) later. PTA was repeated in four patients, but not in two. The mean duration of the primary patency was 336.6 ± 417.2 days (range 17-1,190) and that of the secondary patency was 897.1 ± 801.4 days (range 17-2,230). PTA of a non-mainstream venous route is useful for restoring an occluded hemodialysis fistula when the mainstream outflow vein cannot be traversed.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... use of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter ... use of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  12. Percutaneous balloon angioplasty of coarctation of the aorta in children: 12-year follow-up results%经皮球囊血管成形术治疗先天性主动脉缩窄:12年随访结果

    Institute of Scientific and Technical Information of China (English)

    李奋; 周爱卿; 高伟; 王荣发; 余志庆; 黄美蓉; 杨建萍

    2001-01-01

    目的总结我院27例次经皮球囊血管成形术治疗先天性主动脉缩窄12年随访结果,以评价该介人方法的长期疗效及影响疗效的因素。方法 1987年9月至1999年8月,共有24例先天性主动脉缩窄患儿接受了27次经皮球囊血管成形术治疗,其中19例为局限性峡部缩窄(隔膜型),4例为主动脉弓发育不良型,1例为手术后再狭窄。选择的球囊直径一般不超过缩窄段近端主动脉直径(11.06±2.80mm与11.78±3.18mm),球囊/缩窄段之比为2~4(平均2.57±0.68)。术后随访6月~12年,平均6.2±2.8年。跨缩窄段压差≤20 mm Hg为疗效良好。结果术后跨缩窄段压差由48.17±14.68 mm Hg下降至14.96±13.12 mm Hg(P<0.01),缩窄段直径由4.66±2.43 mm增加至8.80±3.32 mm(P<0.01)。19例(79%)患儿即刻疗效良好。5例疗效不良患儿中,4例为发育不良型,1例为隔膜型。19例疗效良好患儿中,18例为隔膜型,1例为手术后再狭窄。1例隔膜型初次疗效良好的患儿随访中压差上升至30 mm Hg,2年半后接受第二次扩张术并获良好疗效;1例发育不良型患儿即刻疗效不佳,7年后再次行扩张术但疗效仍不理想;1例隔膜型但初次疗效不佳的患儿7年后再次行扩张术获良好效果。随访中无动脉瘤及其它并发症发生。结论经皮球囊血管成形术可有效治疗手术后复发性或隔膜型主动脉缩窄,对发育不良型治疗效果不佳。%Objective To evaluate the efficiency of percutaneous balloon angioplasty of coarctation ot the aorta in children and discuss its risk factors that can lead to poor long-term results. Mehods From September 1987 to August 1999, 24 patients underwent 27 balloon angioplasty procedures for native or recurrent coarctation of the aorta at our institution. There were 19 patients with discrete (membranous) coarctation, 4 patients with long-segment and aortic arch hypoplasia, and 1 patient with postoperative

  13. Study of the stenosis-inhibiting effects of high-dose rate endovascular irradiation in balloon injured rabbit iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Masao; Sekine, Hiroshi; Suzuki, Akihiko; Ohyama, Noriaki; Hataba, Yoshiaki [Jikei Univ., Tokyo (Japan). School of Medicine

    2002-12-01

    With scanning electron microscopy, we investigated the effectiveness of inhibition by endovascular irradiation (Ir-192 high dose rate) of intimal hyperplasia after angioplasty. We also examined changes in the irradiated arterial vessel wall after balloon injury and the mechanism of the inhibition of intimal hyperplasia. Japanese white rabbits (male, 3.0-3.5 kg) were used. Under anesthesia, a percutaneous transluminal angioplasty balloon catheter was inserted into the iliac arteries and inflated to 6 atm for 1 minute 3 times at 1-minute intervals. One artery was irradiated (12 Gy) with an iridium-192 high-dose rate endovascular irradiation device (the reference point was set at 2 mm to center; dose rate 18-48 Gy/min). From 2 days to 12 weeks after the procedure, fixation was performed at a perfusion pressure of 120 to 150 cm H{sub 2}O, and the arteries were systematically examined. Endothelial cells after balloon injury with or without irradiation were examined with light microscopy or scanning electron microscopy. Endovascular irradiation inhibited intimal hyperplasia for at least 12 weeks. Irradiated arteries were not constricted, so we assumed that this phenomenon was caused by inhibition of negative remodeling. From 1 to 2 weeks after the procedure, we recognized mild intimal hyperplasia at nonirradiated arteries, but no hyperplasia recognized at irradiated arteries. This hyperplasia was mainly constituted by endothelial cells, and this change happened at least 2 days with scanning electron scopy. At the injury site, platelet aggregation, thrombus, and endothelial cells were observed. After irradiation, endothelial cells and nuclei were injured. Hypertrophic nuclei, the deformity of cell alignment, and stratified endothelial cells were recognized. It means that irradiation may affect the metabolism of the endothelial cells against normal formation with light microscopy. (author)

  14. Technique of spinal cord compression induced by inflation of epidural balloon catheter in rabbits (Oryctologus cuniculus): efficient and easy to use model.

    Science.gov (United States)

    Fonseca, Antonio F B DA; Scheffer, Jussara P; Coelho, Barbara P; Aiello, Graciane; Guimarães, Arthur G; Gama, Carlos R B; Vescovini, Victor; Cabral, Paula G A; Oliveira, André L A

    2016-09-01

    The most common cause of spinal cord injury are high impact trauma, which often result in some motor impairment, sensory or autonomic a greater or lesser extent in the distal areas the level of trauma. In terms of survival and complications due to sequelae, veterinary patients have a poor prognosis unfavorable. Therefore justified the study of experimental models of spinal cord injury production that could provide more support to research potential treatments for spinal cord injuries in medicine and veterinary medicine. Preclinical studies of acute spinal cord injury require an experimental animal model easily reproducible. The most common experimental animal model is the rat, and several techniques for producing a spinal cord injury. The objective of this study was to describe and evaluate the effectiveness of acute spinal cord injury production technique through inflation of Fogarty(r) catheter using rabbits as an experimental model because it is a species that has fewer conclusive publications and contemplating. The main requirements of a model as low cost, handling convenience, reproducibility and uniformity. The technique was adequate for performing preclinical studies in neuro-traumatology area, effectively leading to degeneration and necrosis of the nervous tissue fostering the emergence of acute paraplegia.

  15. ROLE OF ENDOGENOUS CARBON MONOXIDE IN NEOINTIMAL FORMATION INDUCED BY BALLOON-INJURY IN RAT AORTA

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Objective.The present study investigated the role of endogenous carbon monoxide(CO)in the pathogenesis of neointimal formation induced by balloon injury in rat.Method.Endothelial denudation of the left common carotid artery of rat was carried out by three passages of a Fogarty 2F balloon catheter.DNA,collagen and elastin contents of each intima-media were estimated;and heme oxygenase(HO)activity and CO production in vascular smooth muscle cell(VSMC)were measured after administration of HO inhibitor.Result.Our data showed that neointima occurred in the rat on day 7 and day 21 after balloon injury,and at the same time HO activity and CO production in VSMC were markedly increased.Administration of HO inhibitor,zinc deuteroporphyrin 2,4-bisglycol(ZnDPBG),could effectively inhibit HO activity and CO production,significantly enhance neointimal formation(aortic intima/media ratio were 21.4±1.8% vs 17.6±2.0%,P<0.05 on day 7;and 30.5±2.4% vs 23.0±2.2%,P<0.01 on day 21,respectively,compared with balloon alone group).Conclusion.We concluded that 1)inhibition of CO production may enhance neointimal formation induced by endothelial denudation,implying endogenous CO play an protective role in response to vascular injury,and 2)induction of HO activity may be applied clinically for preventing restenosis after angioplasty.

  16. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    Science.gov (United States)

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Quantitative angiographic assessment of elastic recoil after percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); K.J. Beatt (Kevin); G-J. Laarman (GertJan); H. Suryapranata (Harry); M.J.B.M. van den Brand (Marcel); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1990-01-01

    textabstractLittle is known about the elastic behavior of the coronary vessel wall directly after percutaneous transluminal coronary angioplasty (PTCA). Minimal luminal cross-sectional areas of 151 successfully dilated lesions were studied in 136 patients during balloon inflation and directly after

  18. Quantitative angiographic assessment of elastic recoil after percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); K.J. Beatt (Kevin); G-J. Laarman (GertJan); H. Suryapranata (Harry); M.J.B.M. van den Brand (Marcel); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1990-01-01

    markdownabstractAbstract Little is known about the elastic behavior of the coronary vessel wall directly after percutaneous transluminal coronary angioplasty (PTCA). Minimal luminal cross-sectional areas of 151 successfully dilated lesions were studied in 136 patients during balloon inflation and

  19. 3-year midterm results following hydrolyser{sup TM} thrombolysis; Langzeit-Ergebnisse nach Hydrolyser-unterstuetzter Angioplastie - eine prospektive Studie

    Energy Technology Data Exchange (ETDEWEB)

    Beyer-Enke, S.A.; Deichen, J.; Zeitler, E. [Staedtisches Klinikum Nuernberg-Nord (Germany). Inst. fuer Diagnostische und interventionelle Radiologie

    1999-08-01

    Purpose: Data of a three-year follow-up after mechanical thrombolysis with the Hydrolyser catheter were evaluated. Patients have otherwise been treated by local thrombolysis. Method: 35 patients were treated by thrombolysis, balloon angioplasty, aspiration, local thrombolysis, and stent placement, if necessary. Morphological results following Hydrolyser treatment and additional treatment were evaluated. Results: Following Hydrolyser treatment a significant reduction of the degree and length of the occlusion was observed. Primary clinical success was 80%. Patency rate after 3 years was 0.5. 23% of all patients died in the follow-up period. Conclusion: The Hydrolyser treatment is a relevant alternative to local thrombolysis. This method reduces the time of treatment. The authors favor the lateral opening of the catheter to remove mural thrombus. (orig.) [German] Ziel: Auswertung der Nachkontrollen von Patienten, die anstelle einer lokalen Lyse mit dem Hydrolyser {sup trademark} -Thrombektomiekatheter (HT), Ballondilatation (PTA), Aspirationsthrombektomie (PAT) oder Stent behandelt wurden. Methode: 35 Patienten wurden behandelt und ueber drei Jahre nachbeobachtet. Alle Patienten hatten thromotische/thrombembolische Verschluesse der unteren Extremitaet. Die Laesionen wurden alle mit dem Hydrolyser {sup trademark} -Katheter behandelt. Abhaengig von der Art der Laesion wurden die unterschiedlichen Zusatzverfahren eingesetzt. Das morphologische Resultat wurde sowohl nach dem Einsatz des Hydrolysers {sup trademark} als auch nach der sekundaeren Therapie beurteilt. Ergebnis: Nach Verwendung des Hydrolysers konnte in 21 Faellen eine weitgehende Rekanalisation erreicht werden. Nach sekundaerer Angioplastie wurde in 31 Faellen ein zufrieden-stellendes Resultat (keine relevante Reststenose) erzielt. Die primaere klinische Erfolgsrate lag bei 28/35 (80%). Die Offenheitsrate nach drei Jahren betrug 0,5. 8 Patienten (23%) waren verstorben. Schlussfolgerung: Das System verkuerzt

  20. Angioplasty simulation using ChainMail method

    Science.gov (United States)

    Le Fol, Tanguy; Acosta-Tamayo, Oscar; Lucas, Antoine; Haigron, Pascal

    2007-03-01

    Tackling transluminal angioplasty planning, the aim of our work is to bring, in a patient specific way, solutions to clinical problems. This work focuses on realization of simple simulation scenarios taking into account macroscopic behaviors of stenosis. It means simulating geometrical and physical data from the inflation of a balloon while integrating data from tissues analysis and parameters from virtual tool-tissues interactions. In this context, three main behaviors has been identified: soft tissues crush completely under the effect of the balloon, calcified plaques, do not admit any deformation but could move in deformable structures, the blood vessel wall undergoes consequences from compression phenomenon and tries to find its original form. We investigated the use of Chain-Mail which is based on elements linked with the others thanks to geometric constraints. Compared with time consuming methods or low realism ones, Chain-Mail methods provide a good compromise between physical and geometrical approaches. In this study, constraints are defined from pixel density from angio-CT images. The 2D method, proposed in this paper, first initializes the balloon in the blood vessel lumen. Then the balloon inflates and the moving propagation, gives an approximate reaction of tissues. Finally, a minimal energy level is calculated to locally adjust element positions, throughout elastic relaxation stage. Preliminary experimental results obtained on 2D computed tomography (CT) images (100x100 pixels) show that the method is fast enough to handle a great number of linked-element. The simulation is able to verify real-time and realistic interactions, particularly for hard and soft plaques.

  1. Percutaneous transluminal angioplasty for atherosclerotic stenosis of the intracranial cerebral arteries. initial results and long-term follow-up.

    Science.gov (United States)

    Hyodo, A; Kato, N; Nakai, Y; Anno, I; Sato, H; Okazaki, M; Matsumaru, Y; Nose, T

    1999-11-01

    Percutaneous transluminal angioplasty (PTA) was carried out 52 times for 49 lesions in 47 cases of atheroscrelotic stenosis of the intracranial or skull base cerebral arteries. The stenotic lesions involved the middle cerebral artery in 21 cases, the basilar artery in eight cases, the internal carotid artery (petrous-supraclinoid portion) in 15 cases, and the intracranial vertebral artery in five cases. Nearly all cases were symptomatic, such as TIA or stroke, and the degree of stenosis ranged from 70 to 99 percent, with a mean of 80 percent. PTA was performed using a STEALTH balloon angioplasty catheter. In these trials, PTA was successfully performed (as indicated by a residual stenosis under 50%) 41 times. The initial success rate was 79% and stenosis was reduced from 80% to 25%. Clinical follow-up was performed from 7 to 84 months with a mean of 44 months. During this period, death due to myocardial infarction or pneumonia occurred in five cases, stroke related to previous PTA occurred ih one case (due to re-stenosis) and stroke unrelated tl? previous PTA occurred in two cases. Angiographic follow-up was performed in 31 cases after 41 successful PTA procedures. Re-stenosis was seen in 20% of the cases, symptomrltic complications occurred in 6%, and asymptomatic complications occurred in 6% of the cases. One case suffered severe subarachnoid hemorrhage just after the PTA due to preexisting aneurysm rupture and he died a week after the PTA. So mortality in this series was 2%. From the results described here, we may conclude that PTA of the intracranial or skull base cerebral artery is technically feasible, and it can be performed with relatively low risk. From our results, it may be a useful method and effective for long-term survival of patients. But results from a larger number of patients and more long-term follow-up data are still necessary in order to evaluate the safety and usefulness of this method.

  2. [Percutaneous angioscopy and angioplasty in the treatment of arteriopathies of the lower limbs].

    Science.gov (United States)

    Baudrillard, J C; Foucart, H; Defache, C H; Lerais, J M; Cécile, J P

    1993-05-01

    Since 1987, the authors have routinely combined angioscopy with angioplasty of peripheral arteries. In a series of 251 angioplasties carried out in 191 patients, angioscopy was found to be more specific and more sensitive than arterial angiography in the etiological diagnosis of arterial stenoses and/or obstructions. Angioscopic findings modified the angioplasty procedure in 29% of cases. Using an inflatable catheter remains the most commonly used approach (230 cases); in 10 cases, this was preceded by thromboaspiration and in 4 cases by dotterization. Angioscopic support was useful in carrying out difficult manoeuvres (monitoring of the angioplasty in 4 cases, correct orientation of the guide into the lumen in 14 cases, installation of an endoprosthesis in 9 cases, arterial biopsy in 5 cases and sampling of an atheroma in 8 cases).

  3. Immediate versus deferred coronary angioplasty in non-ST-segment elevation acute coronary syndromes

    NARCIS (Netherlands)

    Riezebos, R.K.; Ronner, E.; ter Bals, E.; Slagboom, T.; Smits, P.C.; ten Berg, J.M.; Kiemeneij, F.; Amoroso, G.; Patterson, M.S.; Suttorp, M.J.; Tijssen, J.G.P.; Laarman, G.J.

    2009-01-01

    BACKGROUND: The field of acute coronary syndromes is characterised by an increasing tendency towards early invasive catheter-based diagnostics and therapeutics-a practice based on observational and retrospective data. OBJECTIVE: To compare immediate versus deferred angioplasty in patients with non-S

  4. Laser angioplasty of totally occluded arteries of the limb

    Science.gov (United States)

    Szopinski, Piotr; Hara, Marek; Noszczyk, Wojciech

    1996-03-01

    The authors summarize their experience in the use of Nd-YAG laser in chronic occlusion of lower limb arteries. Percutaneous transluminal laser angioplasty (PTLA) with laser-heated metal and sapphire tips were used as an adjuvant to conventional balloon angioplasty. In cases of reocclusions, endovascular stents were implanted. Laser recanalization was performed in 46 arteries (iliac, superficial femoral, and popliteal). Indications for the procedure were: limb salvage, claudication below 100 m, and temporal or rest pain. Initial clinical and hemodynamic improvement was observed in 37 (80%) patients. Four perforations occurred without clinical sequel. The one-year cumulative clinical patency was 27 (58%) of the 46 lesions. PTLA may be appropriate for high-risk patients, who are unsuitable for surgical reconstruction because of the concomitant diseases. The combination of laser recanalization and implantation of vascular stents may be a promising method in the management of limb ischemia.

  5. 脉冲电场介导AT2R基因在血管局部表达及其对血管新生内膜的影响%Electroporation-mediated angiotensin Ⅱ type 2 receptor expression improves neo intimal hyperplasia of carotid arteries in rats after balloon angioplasty

    Institute of Scientific and Technical Information of China (English)

    刘德峰; 屈小玲; 刘建平

    2011-01-01

    Objective To determine the effects of electroporation on the transfection of angiotensin Ⅱ type 2 receptor (AT2R) gene into rat carotid arteries and predict its role in neointimal hyperplasia of carotid arteries after balloon angioplasty. Methods After the establishment of rat carotid balloon injury restenosis model, 18 SD rats were divided into AT2R transfection group, empty plasmid transfection group (GFP), and non-transfection group (n = 6 ). AT2R gene plasmid or empty plasmid was transfected by electroporation into rat carotid arteries. Their arteries were harvested at 3, 14 and 21 d after gene transfer, with 2 rats at each time points. The expression of AT2B and morphology of the arteries were evaluated by immunohistochemistry and HE staining respoctively. Results Electroporation-mediated transfection of AT2R gene into injured rat carotid arteries significantly up-regulated the levels of AT2R mRNA in the neointima in a time dependent manner from day 3 to day 14 ( strong to moderate to mild expression). But no expression of AT2B was found in the other 2 groups at these 3 time points. At day 21, AT2R transfection significantly reduced intimal/medial area ratio as compared with non-transfection group and GFP transfection group (0.76 ± 0.08 vs 1.39 ± 0.08 and 1.32 ± 0. 10, P < 0.01 ). No significant difference was found between non-transfection group and GFP transfection group. Conclusion Our results indicate that electroporation is an effective means to introduce naked AT2R DNA into the blood vessel wall, and gene transfer of AT2R in vessel wall may effectively inhibit VSMC proliferation and neointimal hyperplasia in the rat carotid arteries after balloon angioplasty.%目的 研究脉冲电场对血管紧张素2型受体(AT2R)基因在血管局部表达的作用,探讨AT2R基因在体转染对大鼠颈动脉球囊损伤后新生内膜增生的作用.方法 大鼠颈动脉球囊损伤后,用脉冲电穿孔法介导AT2R cDNA真核表达质粒或空质粒载

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... What are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical ... them appear bright white. top of page How is the procedure performed? This examination is usually done ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic tube, ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  13. [Percutaneous angioplasty (PTA) in the treatment of non-penetrating injuries to the subclavian artery. A clinical case].

    Science.gov (United States)

    Giordanengo, F; Boneschi, M; Giorgetti, P L; Lovaria, A

    1996-05-01

    Non penetrating injuries to the subclavian vessels are uncommon. We present a case of a young patient with an isolated blunt trauma of the right subclavian artery. The patient, a 25 year-old woman, was admitted to our Institute after a motor-vehicle accident, with a physical findings of absent peripheral pulses and right clavicular fracture, confirmed by non-invasive vascular evaluation and X-ray of the chest. Diagnosis was established by an urgent selective angiography that showed a subintimal hematoma with occlusion of the vessel and peripheral ischemia of the arm. The patient clinical status (hemodynamically stable) permitted a conservative management and a transluminal percutaneous angioplasty (PTA) with a trans-femoral catheter balloon. After radiologic treatment, the patient showed good palpable peripheral pulses. Clavicular fracture was treated by esternal stabilization. We believe that in selected patients, without other serious life-threatening injures, the intimal artery injury can be treated by a conservative and now also radiologic Therapy; PTA treatment avoids morbidity and mortality associated with surgical intervention.

  14. Percutaneous angioplasty of portal vein stenosis that complicated liver transplantation: the mid-term therapeutic results

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Bo; Choo, Sung Wook; Do, Young Soo; Shin, Sung Wook; Cho, Sung Gi; Choo, In Wook [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2005-09-15

    We wanted to valuate the mid-term therapeutic results of percutaneous transhepatic balloon angioplasty for portal vein stenosis after liver transplantation. From May 1996 to Feb 2005, 420 patients underwent liver transplantation. Percutaneous transhepatic angioplasty of the portal vein was attempted in six patients. The patients presented with the clinical signs and symptoms of portal venous hypertension or they were identified by surveillance doppler ultrasonography. The preangioplasty and postangioplasty pressure gradients were recorded. The therapeutic results were monitored by the follow up of the clinical symptoms, the laboratory values, CT and ultrasonography. The overall technical success rate was 100%. The clinical success rate was 83% (5/6). A total of eight sessions of balloon angioplasty were performed in six patients. The mean pressure gradient decreased from 14.5 mmHg to 2.8 mmHg before and after treatment, respectively. The follow up periods ranged from three months to 64 months (mean period; 32 months). Portal venous patency was maintained in all six patients until the final follow up. Combined hepatic venous stenosis was seen in one patient who was treated with stent placement. One patient showed puncture tract bleeding, and this patient was treated with coil embolization of the right portal puncture tract via the left transhepatic portal venous approach. Percutaneous transhepatic balloon angioplasty is an effective treatment for the portal vein stenosis that occurs after liver transplantation, and our results showed good mid-term patency with using this technique.

  15. Endovascular brachytherapy (EVBT) with rhenium-188 for restenosis prophylaxis after angioplasty of infrainguinal lesions. Early experience; Endovaskulaere Brachytherapie (EVBT) mit Rhenium-188 zur Restenoseprophylaxe nach Angioplastie infrainguinaler Laesionen. Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Leissner, G.G.; Winterstein, A.; Bohndorf, K.; Wohlgemuth, W.A. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie; Wengenmair, H. [Klinikum Augsburg (Germany). Medizinische Physik und Strahlenschutz; Sciuk, J. [Klinikum Augsburg (Germany). Klinik fuer Nuklearmedizin; Woelfle, K.D. [Klinikum Augsburg (Germany). Klinik fuer Gefaesschirurgie; Weinrich, K. [Klinikum Augsburg (Germany). II. Medizinische Klinik, Angiologie

    2011-08-15

    Purpose: Restenosis remains a major problem in percutaneous transluminal angioplasty (PTA) of peripheral arteries. The aim of this feasibility study was to evaluate the technical feasibility and safety of a new endovascular brachytherapy (EVBT) device with Rhenium-188 in restenosis prophylaxis of infrainguinal arteries. Materials and Methods: From March 2006 to April 2009, 52 patients with 71 infrainguinal arterial lesions were treated with Re-188 to prevent restenosis after PTA. 40 patients with 53 lesions (24 de-novo lesions and 29 restenoses) were reexamined (clinic, color-coded duplex ultrasound) after a mean follow-up period of 12.7 months (2.6 to 25.1 months). The liquid beta-emitter Re-188 was introduced to the target lesion via an EVBT certified PTA balloon and a tungsten applicator. After the calculated irradiation time, Re-188 was aspirated back into the tungsten applicator. A dose of 13 Gy was applied at a depth of 2 mm into the vessel wall. Results: After a mean follow-up of 12.7 months, the overall restenosis rate after Re-PTA was 15.1 % (8/53 lesions). The restenosis rate for de-novo lesions was 20.8 % (5/24) and 10.3 % for restenoses (3/29). In 4 patients reintervention was necessary (3 PTAs and 2 major amputations). No periprocedural complications were observed. No elevated radiation dose for the patient or the interventionalist was measured. Conclusion: EVBT with a Re-188 filled balloon catheter was technically feasible and safe after PTA of infrainguinal arterial lesions with restenosis rates lower than expected compared to published results. Treatment of restenoses seems to be more effective than de-novo lesions. (orig.)

  16. Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons.

    Science.gov (United States)

    Antony, Kathleen M; Racusin, Diana A; Belfort, Michael A; Dildy, Gary A

    2017-04-01

    Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling.

  17. The stuck catheter: a hazardous twist to the meaning of permanent catheters.

    Science.gov (United States)

    Vellanki, Venkat Sainaresh; Watson, Diane; Rajan, Dheeraj K; Bhola, Cynthia B; Lok, Charmaine E

    2015-01-01

    Permanent central venous catheter use is associated with significant complications that often require their timely removal. An uncommon complication is resistant removal of the catheter due to adherence of the catheter to the vessel wall. This occasionally mandates invasive interventions for removal. The aim of this study is to describe the occurrence of this "stuck catheter" phenomenon and its consequences. A retrospective review of all the removed tunneled hemodialysis catheters from July 2005 to December 2014 at a single academic-based hemodialysis center to determine the incidence of stuck catheters. Data were retrieved from a prospectively maintained computerized vascular access database and verified manually against patient charts. In our retrospective review of tunneled hemodialysis catheters spanning close to a decade, we found that 19 (0.92%) of catheters were retained, requiring endovascular intervention or open sternotomy. Of these, three could not be removed, with one patient succumbing to catheter-related infection. Longer catheter vintage appeared to be associated with 'stuck catheter'. Retention of tunneled central venous catheters is a rare but important complication of prolonged tunneled catheter use that nephrologists should be aware of. Endoluminal balloon dilatation procedures are the initial approach, but surgical intervention may be necessary.

  18. BALLOON CATHETER DILATION PADA RINOSINUSITIS KRONIS

    Directory of Open Access Journals (Sweden)

    Olivia Tantana

    2014-09-01

    Full Text Available Prevalensi rinosinusitis kronis cukup tinggi dan pengobatannya memerlukan biaya besar. Bilapengobatan tidak memuaskan maka tindakan pembedahan merupakan pilihan terbaik. Ballooncatheter dilation merupakan teknik baru untuk penanganan sinusitis. Alat ini dirancang untukmenghasilkan mikrofraktur dan membentuk ulang tulang di sekitar ostium sinus. Teknik ini dapatmengurangi risiko perdarahan dan telah diakui oleh The United Stated Food and Drugs Association.[MEDICINA 2013;44:93-96].

  19. Properties of nylon 12 balloons after thermal and liquid carbon dioxide treatments.

    Science.gov (United States)

    Ro, Andrew J; Davé, Vipul

    2013-03-01

    Critical design attributes of angioplasty balloons include the following: tear resistance, high burst pressures, controlled compliance, and high fatigue. Balloons must have tear resistance and high burst pressures because a calcified stenosis can be hard and nominal pressures of up to 16 atm can be used to expand the balloon. The inflated balloon diameter must be a function of the inflation pressure, thus compliance is predictable and controlled. Reliable compliance is necessary to prevent damage to vessel walls, which may be caused by over-inflation. Balloons are often inflated multiple times in a clinical setting and they must be highly resistant to fatigue. These design attributes are dependent on the mechanical properties and polymer morphology of the balloon. The effects of residual stresses on shrinkage, crystallite orientation, balloon compliance, and mechanical properties were studied for angioplasty nylon 12 balloons. Residual stresses of these balloons were relieved by oven heat treatment and liquid CO2 exposure. Residual stresses were measured by quantifying shrinkage at 80 °C of excised balloon samples using a dynamic mechanical analyzer. Shrinkage was lower after oven heat treatment and liquid CO2 exposure compared to the as-received balloons, in the axial and radial directions. As-received, oven heat treated, and liquid CO2-exposed balloon samples exhibited similar thermal properties (T(g), T(m), X(t)). Crystallite orientation was not observed in the balloon cylindrical body using X-ray scattering and polarized light microscopy, which may be due to balloon fabrication conditions. Significant differences were not observed between the stress-strain curves, balloon compliance, and average burst pressures of the as-received, oven heat treated, and liquid CO2-exposed balloons.

  20. Pharmacomechanical thrombectomy with the Castañeda brush catheter in thrombosed hemodialysis grafts and native fistulas.

    Science.gov (United States)

    Heye, Sam; Van Kerkhove, Filip; Claes, Kathleen; Maleux, Geert

    2007-11-01

    To evaluate the safety and efficacy of the Castañeda brush catheter in the treatment of thrombosed hemodialysis fistulas and grafts. Twenty-six revascularization procedures with the Castañeda brush catheter combined with urokinase were retrospectively analyzed in 21 patients (mean age, 69 years; range, 35-87 y). Hemodialysis shunts were native arteriovenous (AV) fistulas (n=15; 16 procedures) or polytetrafluoroethylene grafts (n=6; 10 procedures). Major outcomes included procedure time, anatomic and clinical success rates, complication rate, and primary, primary assisted, and secondary patency. In 26 procedures, the brush catheter was used in combination with a mean dose of 239,792 IU urokinase (range, 60,000-300,000 IU). Additional angioplasty was performed in all procedures; five procedures (19%) required additional stent implantation. Mean procedure time was 99.2 minutes (range, 49-261 min). Anatomic and clinical success rates were 100% and 96.2%, respectively. Two minor complications (8%) occurred, neither of which was device-related: one case of extravasation treated by balloon tamponade and one hematoma at the distal puncture site without the need for surgery or transfusion. Primary patency rates were 87%, 62%, and 50% at 3, 6, and 12 months, respectively, for AV fistulas, and 50%, 33%, and 17%, respectively, for grafts. Assisted primary patency rates were 93%, 77%, and 70% at 3, 6, and 12 months, respectively, for AV fistulas, and 50%, 33%, and 17%, respectively, for grafts. At 3, 6, and 12 months, secondary patency rates were 93%, 85%, and 80%, respectively, for AV fistulas, and 83%, 67%, and 50%, respectively, for grafts. The Castañeda brush catheter is a safe and effective pharmacomechanical thrombectomy device for the treatment of thrombosed hemodialysis grafts and native fistulas.

  1. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall

    1997-01-01

    arteries remained patent. Two occlusions and two stenoses developed during the first 3 months after the intervention and one occlusion occurred after 1 year. The following IVUS parameters were related to a favourable patency: presence of calcification; dissection or plaque rupture and residual stenosis...

  2. Percutaneous laser thermal angioplasty: initial clinical results with a laser probe in total peripheral artery occlusions.

    Science.gov (United States)

    Cumberland, D C; Sanborn, T A; Tayler, D I; Moore, D J; Welsh, C L; Greenfield, A J; Guben, J K; Ryan, T J

    1986-06-28

    A metal-tipped laser fibre was used during percutaneous angioplasty of femoral/popliteal or iliac artery occlusions in 56 patients. Primary success was achieved in 50 (89%) of these total occlusions, providing a channel for subsequent balloon dilatation. Before the procedure, 18 lesions had been judged untreatable by conventional angioplasty and four of the six failures were in these. Complications directly attributable to the laser probe were one case of vessel perforation and two cases of entry into vessel walls; these had no sequelae. Other acute complications were a distal thrombosis in a non-heparinised patient, requiring local streptokinase treatment, and two reocclusions and one transient peripheral embolic episode in the first 24 hours. The laser probe technique has potential for increasing the proportion of patients suitable for angioplasty.

  3. Influences on vascular wall smooth muscle cells with novel short-duration thermal angioplasty

    Science.gov (United States)

    Kunio, M.; Shimazaki, N.; Arai, T.; Sakurada, M.

    2012-02-01

    We investigated the influences on smooth muscle cells after our novel short-duration thermal angioplasty, Photo-thermo Dynamic Balloon Angioplasty (PTDBA), to reveal the mechanism that can suppress neo-intimal hyperplasia after PTDBA. We obtained the sufficient arterial dilatations by short-duration heating (angioplasty in vivo. The measured neo-intimal hyperplasia occupancy rate was less than 20% after PTDBA in vivo. We prospect that the inhibition of the growth factor's expression by stretch-fixing may result to suppress the neo-intimal hyperplasia. In addition, the decrease of smooth muscle cells' density in the vessel media by heating might be another reason for the neo-intimal hyperplasia suppression.

  4. Intra-Aortic Balloon Pump Rupture and Entrapment

    Directory of Open Access Journals (Sweden)

    Artan Jahollari

    2014-01-01

    Full Text Available Intra-aortic balloon pump is used frequently to support a failing myocardium in cardiac patients. Due to the invasive nature of this device, usage is accompanied by consistent risk of complications. Balloon rupture, although it occurs rarely, may lead to entrapment if diagnosis delays. A 78-year male who underwent cardiac surgery experienced balloon rupture and entrapment in the right femoral artery during the postoperative follow-up. Surgical extraction under local anesthesia was performed and the patient had an uneventful course. Fast and gentle solution of the problem is necessary to prevent further morbidity or mortality related to a retained balloon catheter in these delicate patients.

  5. The clinical application of percutaneous transluminal balloon angioplasty for hemodialysis patients with stenosis of arteriovenous ifstula%经皮腔内血管成形术在血透患者动静脉内瘘血管狭窄中的应用

    Institute of Scientific and Technical Information of China (English)

    郑尘非; 孙文学; 贾秀芬; 缪克凯; 潘慧君; 刘毅; 黄朝兴

    2015-01-01

    Objective: To report the technical success and long-term clinical outcomes of arteriovenous ifstula (AVF) stenosis after percutaneous transluminal balloon angioplasty (PTA).Methods: A total of 30 patients with stenosis of AVF were enrolled. There were 16 men and 14 women, and the median age was 64.8±13.2 years. Mean time between ifstula creation and intervention was 16.5±13.8 months. The mean duration of hemodialysis time was 31.5±30.2 months. They were examined by digital subtraction angiography (DSA) when they under-went PTA. After the treatment of PTA, all of the patients were examined by 64-multislice spiral computed tomog-raphy angiography every 3 months.Results: The technical success rate was 90.0% in the hemodialysis patients (17 native AVFs and 10 arteriovenous grafts). Primary patency at ifrst, second, third, fourth and iffth three months was 100%, 91.3%, 79.5%, 72.6% and 62.2% respectively. Univariate analysis indicated that there was no signiif-cant correlation between the clinical factors (including age, diabetes mellitus, location, length, grade, and number of stenosis) and primary patency (P>0.05).Conclusion: PTA is an effective treatment method for arteriovenous stenosis, which has high rates of technical success and less complication.%目的:探讨经皮腔内血管成形术(PTA)治疗动静脉内瘘(AVF)狭窄的疗效。方法:回顾性分析30例上肢AVF狭窄患者的临床资料,其中男16例,女14例,平均年龄(64.8±13.2)岁;瘘管平均使用时间(16.5±13.8)月,患者平均透析时间(31.5±30.2)月。所有患者在数字减影血管造影(DSA)下行PTA,术后每3个月经64层螺旋CT血管造影对AVF功能进行评估。结果:本组手术成功率90.0%,其中17例自体AVF和10例人工血管动静脉内瘘(AVG)。术后27例患者首次开通率3个月为100%,6个月为91.3%,9个月为79.5%,12个月为72.6%,15个月为62.2%;术后AVF首次通畅率的单因素Cox风

  6. Intravascular optical coherence tomography to characterize tissue deformation during angioplasty: preliminary experiments with artery phantoms

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Pazos, Valérie; Bisaillon, Charles-Étienne; Boulet, Benoit; Lamouche, Guy

    2012-09-01

    We explored the potential of intravascular optical coherence tomography (IVOCT) to assess deformation during angioplasty balloon inflation. Using a semi-compliant balloon and artery phantoms, we considered two experimental scenarios. The goal for the first scenario was to investigate if variation in the elasticity of the structure surrounding the balloon could be sensed by IVOCT monitoring. In this scenario, we used three single-layer phantoms with various mechanical properties. Image analysis was performed to extract the inner and outer diameters of the phantoms at various pressures. The goal for the second scenario was twofold. First, we investigated the IVOCT capability to monitor a more complex balloon inflation process. The balloon was in a folded state prior to inflation. This allowed studying two stages of deformation: during balloon unfolding and during balloon expansion. Second, we investigated IVOCT capability to monitor the deformation in a three-layer phantom used to better mimic a true artery. So, not only were the IVOCT images processed to provide the inner and outer diameters of the phantom, but the layer thicknesses were also determined. In both scenarios, IVOCT monitoring revealed to be very efficient in providing relevant information about the phantom deformation during balloon inflation.

  7. [The practical clinical guidelines of the Sociedad Española de Cardiología on interventional cardiology: coronary angioplasty and other technics].

    Science.gov (United States)

    Esplugas, E; Alfonso, F; Alonso, J J; Asín, E; Elizaga, J; Iñiguez, A; Revuelta, J M

    2000-02-01

    Interventional cardiology has had an extraordinary expansion in last years. This clinical guideline is a review of the scientific evidence of the techniques in relation to clinical and anatomic findings. The review includes: 1. Coronary arteriography. 2. Coronary balloon angioplasty. 3. Coronary stents. 4. Other techniques: directional atherectomy, rotational atherectomy, transluminal extraction atherectomy, cutting balloon, laser angioplasty and transmyocardial laser and endovascular radiotherapy. 5. Platelet glycoprotein IIb/IIIa inhibitors. 6. New diagnostic techniques: intravascular ultrasound, coronary angioscopy, Doppler and pressure wire. For the recommendations we have used the classification system: class I, IIa, IIb, III like in the guidelines of the American College of Cardiology and the American Heart Association.

  8. Primary angioplasty for infarction due to isolated right ventricular artery occlusion

    Institute of Scientific and Technical Information of China (English)

    Anwar; A; Chahal; Min-Young; Kim; Alexander; N; Borg; Yahya; Al-Najjar

    2014-01-01

    We report an unusual case of an isolated right ventricular infarction with haemodynamic compromise caused by spontaneous isolated proximal occlusion of the right ventricular branch of the right coronary artery(RCA), successfully treated by balloon angioplasty. A 58-yearold gentleman presented with epigastric pain radiating into both arms. Electrocardiograph with right ventricular leads confirmed ST elevation in V4 R and a diagnosis of isolated right ventricular infarction was made. Urgent primary percutaneous intervention was performed which revealed occlusion of the right ventricular branch of the RCA. During the procedure, the patient’s blood pressure dropped to 80/40 mm Hg, and echocardiography showed impaired right ventricular systolic function. Despite aggressive fluid resuscitation, the patient remained hypotensive, continued to have chest pain and persistent electrocardiograph changes, and hence balloon angioplasty was performed on the proximal right ventricular branch which restored flow to the vessel and revealed a severe ostial stenosis. This was treated with further balloon angioplasty which restored TIMI 3 flow with resolution of patient’s symptoms. Repeat echocardiography showed complete resolution of theST-elevation in leads V4 R and V5 R and partial resolution in V1. Subsequent dobutamine-stress echocardiography at 4 wk showed good left and right ventricular contractions. The patient was discharged after a 3-d inpatient stay without any complications.

  9. Paclitaxel-coated balloons - Survey of preclinical data.

    Science.gov (United States)

    Schnorr, B; Kelsch, B; Cremers, B; Clever, Y P; Speck, U; Scheller, B

    2010-10-01

    Restenosis following interventions in the coronary or peripheral arteries develops over weeks to months. In coronary arteries the restenosis rate has been markedly reduced since the advent of drug-eluting stents. Non-stent-based methods for local drug delivery enable restenosis inhibition without the need for stent implantation, does not permanently change the structure of the vessel, are repeatable, and seems to be applicable where drug-eluting stents provide insufficient protection. Preclinical data indicate that short exposure of the vessel wall to a lipophilic inhibitor of cell proliferation is sufficient for preventing restenosis. Initial evidence to this effect emerged from an investigation of paclitaxel embedded in a matrix that enhances the solubility and release of the agent from the balloon coating as well as its transfer to the vessel wall. Further corroborating data from preclinical and clinical studies demonstrating a reduction in late lumen loss and lower restenosis rates led to the market introduction of a variety of paclitaxel-coated angioplasty balloons. The effectiveness of restenosis inhibition is not determined by the active agent alone. Other factors that are crucial for the effectiveness and safety of drug-coated angioplasty balloons are the formulation containing the agent and the coating technique. In this review we first outline the development of paclitaxel-coated balloons to then provide an overview of the preclinical results obtained with different paclitaxel-coated balloons and finally compare these with the outcome in patients. The article concludes with a short outlook on initial results with a zotarolimus-coated angioplasty balloon.

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Catheter angiography is used to examine blood ... an hour away. top of page What does the equipment look like? The equipment typically used for ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... iodine. If angiography is essential, a variety of methods is used to decrease risk of allergy: You ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... may also be asked to remove jewelry, removable dental appliances, eye glasses and any metal objects or ... it will make the rest of the procedure pain-free. You will not feel the catheter in ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... injection of contrast material to examine blood vessels in key areas of the body for abnormalities such ... makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most ... catheter angiography to lessen the risk of allergic reaction. Another option is to undergo a different exam ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Catheter angiography is used to examine blood ... an hour away. top of page What does the equipment look like? The equipment typically used for ...

  2. Utility of a scoring balloon for a severely calcified lesion: bench test and finite element analysis.

    Science.gov (United States)

    Kawase, Yoshiaki; Saito, Naritatsu; Watanabe, Shin; Bao, Bingyuan; Yamamoto, Erika; Watanabe, Hiroki; Higami, Hirooki; Matsuo, Hitoshi; Ueno, Katsumi; Kimura, Takeshi

    2014-04-01

    We aimed to investigate the effectiveness of a scoring balloon catheter in expanding a circumferentially calcified lesion compared to a conventional balloon catheter using an in vitro experiment setting and elucidate the underlying mechanisms of this ability using a finite element analysis. True efficacy of the scoring device and the underlying mechanisms for heavily calcified coronary lesions are unclear. We employed a Scoreflex scoring balloon catheter (OrbusNeich, Hong Kong, China). The ability of Scoreflex to dilate a calcified lesion was compared with a conventional balloon catheter using 3 different sized calcium tubes. The thickness of the calcium tubes were 2.0, 2.25, and 2.5 mm. The primary endpoints were the successful induction of cracks in the calcium tubes and the inflation pressures required for inducing cracks. The inflation pressure required for cracking the calcium tubes were consistently lower with Scoreflex (p finite element analysis revealed that the first principal stress applied to the calcified plaque was higher by at least threefold when applying the balloon catheter with scoring elements. A scoring balloon catheter can expand a calcified lesion with lower pressure than that of a conventional balloon. The finite element analysis revealed that the concentration of the stress observed in the outside of the calcified plaque just opposite to the scoring element is the underlying mechanism of the increased ability of Scoreflex to dilate the calcified lesion.

  3. Patency of experimental microvascular autografts of the common carotid artery after balloon dilatation in rats: a technical note and preliminary results.

    Science.gov (United States)

    Friedrich, R E

    1998-10-01

    artery is an established model for the study of wound healing after angioplasty. In this study we have clearly shown the thrombogenic effect of balloon dilatation. Caution should therefore be exercised when using a balloon catheter for the dilatation of occluded arteries.

  4. Severe Ventral Erosion of Penis Caused by Indwelling Urethral Catheter and Inflation of Foley Balloon in Urethra—Need to Create List of “Never Events in Spinal Cord Injury” in order to Prevent These Complications from Happening in Paraplegic and Tetraplegic Patients

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2010-01-01

    Full Text Available Never Events are serious, largely preventable patient safety incidents that should not occur if the available preventative measures have been implemented. We propose that a list of “Never Events” is created for spinal cord injury patients in order to improve the quality of care. To begin with, following two preventable complications related to management of neuropathic bladder may be included in this list of “Never Events.” (i Severe ventral erosion of glans penis and penile shaft caused by indwelling urethral catheter; (ii incorrect placement of a Foley catheter leading to inflation of Foley balloon in urethra. If a Never Event occurs, health professionals should report the incident through hospital risk management system to National Patient Safety Agency's Reporting and Learning System, communicate with the patient, family, and their carer as soon as possible about the incident, undertake a comprehensive root cause analysis of what went wrong, how, and why, and implement the changes that have been identified and agreed following the root cause analysis.

  5. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  6. A control study on the COOK balloon catheter, prostaglandin E2 Suppositories and misoprostol in induction of labor at term%米索前列醇、欣普贝生及COOK宫颈扩张双球囊在足月妊娠引产中的对比研究

    Institute of Scientific and Technical Information of China (English)

    孙秀荣; 林莉; 李静芝; 苏放明

    2014-01-01

    目的 分析米索前列醇、欣普贝生及COOK宫颈扩张双球囊促宫颈成熟的特点,探讨足月妊娠适宜的引产措施.方法 将91例有引产指征、宫颈Bishop评分<6分的足月妊娠初产妇随机分为米索前列醇组(31例)、COOK球囊组(28例)、欣普贝生组(32例),观察各组孕妇宫颈Bishop评分、宫缩情况、产程时间、分娩方式及母胎并发症.结果 欣普贝生组及COOK球囊组促宫颈成熟显效率分别为78.6%、75.0%,明显优于米索前列醇组(22.6%),但欣普贝生组强直性宫缩、胎盘早剥的发生率高于COOK球囊组(P<0.05).欣普贝生组与COOK球囊组剖宫产率比较差异无统计学意义(P> 0.05),但均低于米索前列醇组(P<0.05).三组病例新生儿Apgar评分、脐动脉pH值比较差异无统计学意义(P>0.05).结论 小剂量米索前列醇口服给药促宫颈成熟作用较弱,但给药途径方便,价格便宜,对于经济状况低下人群可考虑使用.欣普贝生诱导宫颈成熟效果明显,但可出现强直性宫缩、第二产程过快、胎盘早剥等不良反应.COOK球囊促宫颈成熟作用温和、不良反应少,是除米索前列醇及欣普贝生外另一种可供选择的促宫颈成熟方法.%Objective To evaluate the effectiveness and safety of Misoprostol,Prostaglandin E2 suppositories and COOK balloon catheter in induction of labor at term.Methods 91 women of full-term pregnancy with indications of induced abortion,and cervical Bishop score <6 were randomly divided into Misoprostol group (31 cases),Prostaglandin E2 group (32 cases) and COOK balloon group (28 women).The improvement of cervical conditions was compared before and after the application.The uterine contraction,labor time,fetus delivery method,situation of maternal and newborn were determined.Results The obvious effective rate in Prostaglandin E2 suppositories was 78.6%,in COOK balloon group it was 75.0%,both were significantly higher than those in

  7. Application of bidirectional subintimal angioplasty in atherosclerotic occlusion of lower extremities%双向内膜下血管成形术在治疗下肢动脉闭塞症中的应用

    Institute of Scientific and Technical Information of China (English)

    路军良; 李京雨; 张强; 徐力扬; 刘涛

    2009-01-01

    Objective To discuss the therapeutic efficacy of bidirectional subintimal angioplasty in the treatment of atherosclerotic occlusive of lower limbs. Methods Five patients with long segment of obstructed artery in lower limb were enrolled in the study. Of five patients, occlusion of the lower segment of abdominal aorta and bilateral iliac artery was seen in one, occlusion of iliac artery in 2 and occlusion of superficial femoral artery in the remaining two. Antegrade subintimal angioplasty procedure was unsuccessful in all five patients as the wire could not be placed into the true lumen, so retrograde subintimal angioplasty by puncturing the distal segment of the occlusive artery was employed. Through the newly created channel the retrograde guide wire was manipulated to be pulled out of vessel through the antegrade catheter. The subintimal tract was dilated with angioplasty balloon and the stent implantation was performed. Results Bidirectional subintimal angioplasty was successfully accomplished in all five patients, with a total of nine stents being implanted. Conclusion Bidirectional subintimal angioplasty is a safe and effective procedure for bringing the subintimal recanalization to success, this technique can be regarded as a remedial measure when unidirectional subintimal angioplasty ends up in failure.%目的 探讨双向内膜下血管成形术在治疗周围动脉完全闭塞性病变中的意义.方法 采用双向内膜下血管成形术治疗5例长段动脉闭塞患者,其中腹主动脉下端合并两侧髂总动脉及髂外动脉闭塞1例,髂外动脉闭塞2例,股浅动脉闭塞2例.在单向内膜下再通时,进人真腔失败后而在患肢闭塞动脉远端血管穿刺,使用导丝从病变对侧进入闭塞段内膜下,在病变内膜下腔,采用导丝贯穿至对侧导管技术,成功后,将导丝从对侧导管引出体外,然后用球囊扩张成型并植入支架.结果 本组5例患者均成功完成双向

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ... may eliminate the need for surgery. Tell your doctor if there's a possibility you are pregnant and ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a regular x-ray ... any possibility that they are pregnant. See the Safety page for more information about pregnancy and x- ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... images are captured using a small dose of ionizing radiation ( x-rays ). top of page What are some common uses of the procedure? Catheter angiography is used to examine blood vessels in key areas of the body, including the: brain neck heart chest abdomen (such as the kidneys ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  13. Correlating coating characteristics with the performance of drug-coated balloons--a comparative in vitro investigation of own established hydrogel- and ionic liquid-based coating matrices.

    Directory of Open Access Journals (Sweden)

    Sebastian Kaule

    Full Text Available Drug-coated balloons (DCB, which have emerged as a therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficacy and safety within a number of clinical studies. In vitro studies elucidating the correlation between coating additive and DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this regard, we examined three different DCB-systems, which were developed in former studies based on the ionic liquid cetylpyridinium salicylate, the body-own hydrogel hyaluronic acid and the pharmaceutically well-established hydrogel polyvinylpyrrolidone, considering coating morphology, coating thickness, drug-loss, drug-transfer to the vessel wall, residual drug-concentration on the balloon surface and entire drug-load during simulated use in an in vitro vessel model. Moreover, we investigated particle release of the different DCB during simulated use and determined the influence of the three coatings on the mechanical behavior of the balloon catheter. We could show that coating characteristics can be indeed correlated with the performance of DCB. For instance, paclitaxel incorporation in the matrix can reduce the drug wash-off and benefit a high drug transfer. Additionally, a thin coating with a smooth surface and high but delayed solubility can reduce drug wash-off and decrease particle burden. As a result, we suggest that it is very important to characterize DCB in terms of mentioned properties in vitro in addition to their clinical efficacy in order to better understand their function and provide more data for the clinicians to improve the tool of DCB in coronary angioplasty.

  14. Sinus Balloon Dilation as Treatment for Acute Sphenoid Sinusitis with Impaired Vision for a Child

    Directory of Open Access Journals (Sweden)

    Yin Zhao

    2016-01-01

    Full Text Available This paper is about sinus balloon dilatation in treatment of acute left sphenoid sinusitis with left impaired vision in a child. Balloon catheter dilatation (BCD of the sinus ostia is a new technique. It has been shown to be a minimally invasive technique to manage chronic sinusitis. However, this method is rarely used in the treatment of acute sinusitis. So far, we know of no reported cases of sinus balloon dilatation in treatment of this case, especially for children.

  15. 经桡动脉路径介入治疗时应用经皮冠状动脉介入治疗导丝和球囊辅助指引导管成功跨越痉挛段33例分析%Feasibility study of guiding catheter passing through spasmodic vess els during percutaneous coronary intervention via radial artery access by the aid of PCI guiding wire and balloon

    Institute of Scientific and Technical Information of China (English)

    倪祝华; 迟永辉; 张大鹏; 邓俊萍; 王益民; 刘广军; 张小良; 赵建红; 张继强; 刘佳胜; 祁树莹; 王乐丰; 杨新春; 王红石; 徐立; 李惟铭; 夏昆; 刘宇; 何冀芳

    2016-01-01

    目的:探讨经桡动脉路径行经皮冠状动脉介入治疗( percutaneous coronary intervention , PCI)血管通路痉挛应用PCI导丝和球囊辅助跨越痉挛段血管的安全性和可行性。方法回顾性分析2014年1月至2015年6月首都医科大学附属北京朝阳医院、临汾市人民医院、晋城心脑血管病医院、临汾市第二人民医院和烟台海港医院经桡动脉路径PCI伴有桡动脉和(或)肱动脉痉挛应用PCI导丝和球囊辅助成功越过痉挛段的33例冠心病患者( A组),并与同期其他术者用常规方法处理痉挛的38例患者( B组)进行比较。观察两种方法指引导管通过痉挛段的成功率以及并发症的发生率等指标,以了解两种方法的优劣。结果两组患者痉挛部位比较,差异无统计学意义( P=0.150),但肱动脉痉挛的发生率均较桡动脉高。 A组指引导管通过率显著高于B组[33例(100.0%)比15例(39.5%),P=0.000];对于指引导管成功通过痉挛段的两组患者,A组较B组所需时间更短( P=0.000),A、B组指引导管通过时间≤5 min的患者分别为30例(90.9%)和2例(13.3%),5~15 min的患者分别为3例(9.1%)和7例(46.7%),>15 min的患者分别为0和6例(40.0%)。 A组患者前臂血肿发生率较B组降低[(2例(6.1%)比7例(18.4%)],但差异无统计学意义( P=0.113)。结论经桡动脉路径PCI血管痉挛应用PCI导丝和球囊辅助可非常安全有效地使指引导管跨越痉挛和(或)夹层段,较应用抗痉挛药物这一常规方法更为安全可行。%Objective To explore the safety and feasibility of guiding catheter passing through spasmodic vessels in patients undergoing percutaneous coronary intervention (PCI) via radial artery access by the aid of PCI guiding wire and balloon .Methods The clinical data of 33 coronary artery disease (CAD

  16. Utilidade do Ultrassom intracardíaco no isolamento de veias pulmonares usando cateter-balão a laser Utilidad del ultrasonido intracardíaco en el aislamiento de venas pulmonares usando catéter-balón láser Utility of intracardiac ultrasound imaging to guide pulmonary vein ablation using laser balloon catheter

    Directory of Open Access Journals (Sweden)

    Luiz Leite

    2009-12-01

    . Se obtuvo el aislamiento completo en 38/59 (64%, y fue significantemente más común sin derrame: [30/38 (79% versus 8/23 (35%, pBACKGROUND: Pulmonary vein isolation (PVI with balloon catheter has been used as the endpoint for AF ablation. OBJECTIVE: To determine the usefulness of intracardiac ultrasound (ICUS to guide PVI using laser balloon catheter. METHODS: 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken. RESULTS: 59 PV were ablated. Mean burn time was 279±177 sec, mean balloon diameter was 23±3 mm, and mean balloon length was 25±4 mm. Complete isolation was achieved in 38/59 (64% cases, and it was significantly more common when there was no leak: [30/38 (79% versus 8/23 (35%, p<0.001]. This occurred regardless of time of laser application (302±223 sec. vs. 266±148 sec., p=ns, laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm, balloon diameter (24± 3 mm vs. 22± 3 mm, p=ns and length (27±4 mm vs. 24±4mm, p=ns. The positive predictive value for predicting incomplete isolation was 65% and the negative predictive value was 83%. CONCLUSION: An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.

  17. Heme oxygenase-1 alleviates cigarette smoke-induced restenosis after vascular angioplasty by attenuating inflammation in rat model.

    Science.gov (United States)

    Ni, Leng; Wang, Zhanqi; Yang, Genhuan; Li, Tianjia; Liu, Xinnong; Liu, Changwei

    2016-03-14

    Cigarette smoke is not only a profound independent risk factor of atherosclerosis, but also aggravates restenosis after vascular angioplasty. Heme oxygenase-1 (HO-1) is an endogenous antioxidant and cytoprotective enzyme. In this study, we investigated whether HO-1 upregulating by hemin, a potent HO-1 inducer, can protect against cigarette smoke-induced restenosis in rat's carotid arteries after balloon injury. Results showed that cigarette smoke exposure aggravated stenosis of the lumen, promoted infiltration of inflammatory cells, and induced expression of inflammatory cytokines and adhesion molecules after balloon-induced carotid artery injury. HO-1 upregulating by hemin treatment reduced these effects of cigarette smoke, whereas the beneficial effects were abolished in the presence of Zincprotoporphyrin IX, an HO-1 inhibitor. To conclude, hemin has potential therapeutic applications in the restenosis prevention after the smokers' vascular angioplasty. Copyright © 2016. Published by Elsevier Ireland Ltd.

  18. Incidence and outcome of radial artery occlusion following transradial artery coronary angioplasty.

    Science.gov (United States)

    Stella, P R; Kiemeneij, F; Laarman, G J; Odekerken, D; Slagboom, T; van der Wieken, R

    1997-02-01

    Coronary angioplasty with 6F guiding catheters via the radial artery is associated with a minimal risk for major entry site-related complications. Although the incidence of radial artery occlusion (RAO) in the literature is approximately 30% after prolonged cannulations, little is known about the incidence and its clinical consequences of RAO following transradial percutaneous coronary angioplasty. In a prospective study, 563 patients with a normal Allen test were evaluated on patency and function of the radial artery after transradial angioplasty, by physical and ultrasound examination at discharge, and at 1 month follow-up. At discharge, 30 patients (5.3%) had clinical evidence of RAO. At follow-up, persistent RAO was found in 16 patients (2.8%). In this study we found a low incidence of RAO after transradial percutaneous coronary angioplasty. None of the patients with temporary or persistent RAO had any major clinical symptoms. Therefore, the occurrence of RAO can be considered a minor complication in patients with a previously good double blood supply to the hand.

  19. Drug-coated balloons are replacing the need for nitinol stents in the superficial femoral artery.

    Science.gov (United States)

    Kitrou, Panagiotis; Karnabatidis, Dimitrios; Katsanos, Konstantinos

    2016-08-01

    Amassed evidence from several randomized controlled trials and high quality meta-analyses clearly support the primary use of paclitaxel-coated balloons (PCB) in the superficial femoral artery over traditional plain balloon angioplasty or primary bare nitinol stenting with significantly lower vascular restenosis, less need for repeat procedures, improved quality of life and potential cost savings for the healthcare system. Stents may be reserved for bail-out in case of a suboptimal dilatation result, and for selected more complex lesions, or in case of critical limb ischemia in order to eliminate vessel recoil and maximize immediate hemodynamic gain. Debulking atherectomy remains unproven, but holds a lot of promise in particular in combination with PCBs, in order to improve compliance of the vessel wall by plaque removal, allow for a better angioplasty result and optimize drug transfer and bioavailability. The present overview summarizes and discusses current evidence about femoropopliteal PCB angioplasty compared to the historical standard of plain old balloon angioplasty and bare nitinol stents. Available evidence is appraised in the context of clinically meaningful results, relevant unresolved issues are highlighted, and future trends are discussed.

  20. Experience with a triple-lumen catheter for autologous stem-cell transplantation

    Directory of Open Access Journals (Sweden)

    Ryan Verity

    2016-06-01

    Full Text Available We relate our experience with the Cook (Cook Medial Inc., Bloomington, IN, USA, triple-lumen hyperalimentation (HAS catheter for treatment related to autologous stem-cell transplant. Nineteen HAS catheters were implanted in the right jugular vein, and tunneled to the right anterior chest wall, under imaging guidance. Retrospectively, we reviewed each catheter. Three patient's experienced “ballooning” of the middle (white lumen of the HAS catheter during routine use. We assessed, time in situ, follow-up imaging, chemotherapy regimen, possibility of systemic or device infection, tissue pathology of the patient's malignancy, and other factors to attempt to determine if there were any associations that could explain the catheter lumen failure. After this pilot study of the HAS-catheter in these 19 patients, we discontinued use of this device at our facility due to mechanical problems of ballooned and obstructed middle lumens. There was no obvious cause, or association, detected to explain the ballooning identified.

  1. The natural history of tunneled hemodialysis catheters removed or exchanged: a single-institution experience.

    Science.gov (United States)

    Alomari, Ahmad I; Falk, Abigail

    2007-02-01

    To track the natural history of tunneled hemodialysis catheters requiring removal or exchange at a single institution. Over a 2-year period, tunneled hemodialysis catheters that presented to interventional radiology for removal or exchange were entered into this retrospective study. Patient demographics, catheter location, dwell time, and indication for removal were recorded. Pull-back contrast venography was performed with imaging over the chest. Catheters were then removed or exchanged. Three hundred thirty-four tunneled dialysis catheters were removed or exchanged in 207 patients; 108 male, median age 53 years. Dwell time, available from 296 catheters, ranged from 1 to 114 days (median, 66 days) for a total of 32,847 catheter days. One hundred three catheters were removed for infection, yielding a rate of infection requiring catheter removal of 3.0 per 1,000 catheter days. One hundred catheters were removed for other working access, and 96 catheters were exchanged for poor function. Two hundred sixty-five were removed or exchanged from the internal jugular vein, 22 from the subclavian vein, and 24 from the femoral vein. One hundred seventy-two (76%) of the 226 catheters studied with contrast had fibrin sheaths; of which 42 had thrombus identified along the catheter tract. One hundred ninety-three catheters were removed, and 141 catheters were exchanged for new catheters with 82 catheters receiving balloon disruption of the fibrin sheath. Approximately one third of tunneled dialysis catheters are removed for infection, one third for other working access, and one third for poor function. Catheters usually remain in the patient for a median of 2 months. Fibrin sheaths associated with hemodialysis catheters are very common. Thrombus formation around the sheath is frequent.

  2. Which angiographic variable best describes functional status 6 months after successful single-vessel coronary balloon angiopasty?

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); J.W. Deckers (Jaap)

    1993-01-01

    textabstractOBJECTIVES. The aim of this study was to determine which quantitative angiographic variable best describes functional status 6 months after coronary balloon angioplasty. BACKGROUND. Several angiographic restenosis criteria have been developed. These can be divided into those that describ

  3. Emergency coronary angioplasty in refractory unstable angina

    NARCIS (Netherlands)

    P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); M.J.B.M. van den Brand (Marcel); K. Balakumaran (Kulasekaram); A.L. Soward; P.G. Hugenholtz (Paul); A.E.R. Arnold (Alfred); B. Mochtar (Bas)

    1985-01-01

    textabstractWe performed percutaneous transluminal coronary angioplasty as an emergency procedure in 60 patients with unstable angina pectoris that was refractory to treatment with maximally tolerated doses of beta-blockers, calcium antagonists, and intravenous nitroglycerin. The initial success

  4. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  5. [Results of emergency coronary artery bypass surgery after failed coronary angioplasty].

    Science.gov (United States)

    Imazeki, T; Yokoyama, M; Murai, N; Kurimoto, Y; Sakurada, M; Simizu, Y

    1995-06-01

    In the past 7 years, 9 emergent or urgent coronary artery bypass operations after failed percutaneous transluminal angioplasty (PTCA) were performed among 947 (PTCA). Since the introduction of coronary perfusion catheter system for the support of coronary perfusion during PTCA we could reduce the number of emergent cases and these patients could be operated on semi-emergently and securely without endangering co-medical staffs in a hurry. It is also unnecessary to be on standby all the time when the PTCA is being undertaken. Two acute myocardial infarction cases died in the early phase of this study (operative mortality 22%) and none after the introduction of coronary perfusion system during PTCA.

  6. Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra.

    Science.gov (United States)

    Vaidyanathan, Subramanian; Singh, Gurpreet; Hughes, Peter L; Soni, Bakul M

    2016-01-01

    A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way Foley catheter with a 30-mL balloon but inflated the balloon with 10 mL of water to commence the bladder irrigation. The creatinine level was mostly 19 µmol/L (range: 0-135 µmol/L) but increased to 46 µmol/L on day 7. Computerized tomography urogram revealed that the bilateral hydronephrosis with hydroureter was extended down to urinary bladder, the bladder was distended, prostatic urethra was dilated and filled with urine, and although the balloon of Foley catheter was not seen in the bladder, the tip of the catheter was seen lying in the urethra. Following the re-catheterization, the creatinine level decreased to 21 µmol/L. A follow-up ultrasound scan revealed no evidence of hydronephrosis in both kidneys. Flexible cystoscopy revealed inflamed bladder mucosa, catheter reaction, and tiny stones. There was no bladder tumor. This case report concludes that the cause of bilateral hydronephrosis, hydroureter, and distended bladder was inadequate drainage of urinary bladder as the Foley balloon that was under-filled slipped into the urethra resulting in an obstruction to urine flow. Urethral catheterization in tetraplegic patients should be performed by senior, experienced staff in order to avoid trauma and incorrect positioning. Tetraplegic subjects with decreased muscle mass have low creatinine level. Increase in creatinine level (>1.5 times the basal level) indicates acute kidney injury, although peak creatinine level may still be within laboratory reference range. While scanning the urinary tract of spinal cord injury patients with indwelling urinary catheter, if Foley balloon is not seen within the bladder, urethra should be scanned to locate the Foley balloon.

  7. Hemodialysis Tunneled Catheter Noninfectious Complications

    Science.gov (United States)

    Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil

    2016-01-01

    Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined.

  8. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    Science.gov (United States)

    Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young

    2015-01-01

    The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all pcesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  9. Scientific ballooning in Brazil

    Science.gov (United States)

    Corrêa, R.; Rinke, E.; Fernandes, J. O.; Villela, T.

    We present an overview of the scientific ballooning activities that took place in Brazil over the past 30 years as well as the current ongoing efforts in the area. We also briefly describe the balloon launching facility that exists at the Instituto Nacional de Pesquisas Espaciais (National Institute for Space Research) — INPE. Up to now, over 100 scientific balloon experiments, related to Astrophysics, Aeronomy, and Geophysics were launched from Brazil taking advantage of the country's continental dimensions, a well-defined rain season, and a low population density, which offer excellent conditions for scientific ballooning activities. Balloons with volumes up to 500,000 cubic meters can be launched from INPE's balloon launching base (latitude S 22° 4' 2″; longitude W 044° 58' 41″). The availability of good roads and several inland airports in Brazil provides the necessary structure for safe payload retrieval and its rapid return to the balloon base. There are several airports throughout Brazil that can also be used as balloon launching bases, mainly in the country's Eastern region. Overflights of more than 1,000 kilometers are possible and easily attained. Balloon flights ranging from a few hours to long duration flights can be safely verified. The constant climate monitoring through the use of weather satellites information received at INPE provides the necessary data to determine the necessary conditions for a long duration flight. INPE's Center for Weather Forecast and Climate Studies (CPTEC) provides the necessary weather forecast support for launch and payload retrieval.

  10. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  11. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.

    Directory of Open Access Journals (Sweden)

    Hee Young Cho

    Full Text Available The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation.We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL.Sixty-four patients (46.7% required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1% had placenta previa totalis. The overall success rate was 75% (48/64 for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05. The drainage amount over 1 hour was 500 mL (20-1200 mL in the balloon failure group and 60 mL (5-500 mL in the balloon success group (p<0.01.Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.

  12. The Application of Dual-wire Balloon in The Treatment of Coronary Bifurcation Lesions

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objectives To assess the efficiency and safety of dual-wire balloon angioplasty side branch combined stenting the main branch in the treatment of coronary bifurcation lesions. Methods This study included thirty-six patients with 41 coronary bifurcation lesions. Selective dual-wire balloon angioplasty was performed in side branch and/or in main branch, and implantation of stents was performed in main branch only. Clinical outcome and major adverse cardiac events were observed inhospital and follow-up. Results Success rate of side branch dilatation before main branch stenting was 100%; main branch direct stenting performed in 4 cases; success main branch dilatation performed in the other 37 cases; kissing technique was performed successfully in 5 cases, which side branch was jailed after main branch stenting with TIMI grade 0-2 flow. No Q-wave myocardial infarction, acute revascularization and death occurred during in-hospital.Clinical follow-up was available in all patients. No Q-wave myocardial infarction, revascularization and death occurred, angina pectoris recurred in three patients,released by strengthen drug treatment. Conclusions Dual-wire balloon angioplasty side branch combined stenting the main branch is simple, safe and effective for the treatment of coronary bifurcation lesions.

  13. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  14. Central venous catheters and catheter locks in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Schrøder, Henrik

    2013-01-01

    To determine if the catheter lock taurolidine can reduce the number of catheter-related bloodstream infections (CRBSI) in pediatric cancer patients with tunneled central venous catheters (CVC).......To determine if the catheter lock taurolidine can reduce the number of catheter-related bloodstream infections (CRBSI) in pediatric cancer patients with tunneled central venous catheters (CVC)....

  15. Role of interferon-γ on smooth muscle cells proliferation and migration after balloon injury by inhibiting transforming growth factor-β signal pathway

    Institute of Scientific and Technical Information of China (English)

    MEI Yu; WANG Gui-zhao; HUANG Yong-lin

    2003-01-01

    @@ Objective Restenosis after balloon angioplasty resuits from abnormal proliferation of phenotypically modulated vascular smooth muscle cells (SMCs) that migrate and synthesize large amounts of extracellular matrix. A vafety of growth factors have been shown to play a role in the development of restenotic lesions including transforming growth factor-β (TGF-β).

  16. [Subintimal angioplasty and diabetic foot revascularisation].

    Science.gov (United States)

    Pierret, Charles; Tourtier, Jean-Pierre; Bordier, Lise; Blin, Emmanuel; Duverger, Vincent

    2011-01-01

    Diabetic wounds foot are responsible for 5-10% minor or major amputation in France. In fact, amputation risk of lower limbs is 15-30% higher for diabetic patients. University of Texas classification (UT) is the reference for diabetic foot wound. It distinguish non ischemic and ischemic wound with more amputation. If ischaemia is combined, revascularization may be considered for salvage of the limb. Some revascularization techniques are well known: as surgical by-pass, angioplasty with or without stent, or hybrid procedures with the both. Subintimal angioplasty is a more recent endovascular technique, in assessment for old patients who are believed to be unsuitable candidates for conventional by-pass or angioplasty.

  17. Holmium:YAG laser angioplasty: treatment of acute myocardial infarction

    Science.gov (United States)

    Topaz, On

    1993-06-01

    We report our clinical experience with a group of 14 patients who presented with acute myocardial infarction. A holmium:YAG laser was applied to the infarct-related artery. This laser emits 250 - 600 mJ per pulse, with a pulse length of 250 microseconds and repetition rate of 5 Hz. Potential benefits of acute thrombolysis by lasers include the absence of systemic lytic state; a shortened thrombus clearing time relative to using thrombolytics; safe removal of the intracoronary thrombus and facilitation of adjunct balloon angioplasty. Potential clinical difficulties include targeting the obstructive clot and plaque, creation of debris and distal emboli and laser-tissue damage. It is conceivable that holmium:YAG laser can be a successful thrombolytic device as its wave length (2.1 microns) coincides with strong water absorption peaks. Since it is common to find an atherosclerotic plaque located under or distal to the thrombotic occlusion, this laser can also be applied for plaque ablation, and the patient presenting with acute myocardial infarction can clearly benefit from the combined function of this laser system.

  18. Small coronary vessel angioplasty: outcomes and technical considerations

    Directory of Open Access Journals (Sweden)

    Sudhir Rathore

    2010-10-01

    Full Text Available Sudhir RathoreDepartment of Cardiology, Atkinson Morley wing, St George’s Healthcare NHS Trust, London, UKAbstract: Small vessel (<3 mm coronary artery disease is common and has been identified as independent predictor of restenosis after percutaneous coronary intervention. It remains controversial whether bare-metal stent (BMS implantation in small vessels has an advantage over balloon angioplasty in terms of angiographic and clinical outcomes. Introduction of drug-eluting stent (DES has resulted in significant reduction in restenosis and the need for repeat revascularization. Several DESs have been introduced resulting in varying reduction in outcomes as compared with BMS. However, their impact on outcomes in small vessels is not clearly known. It is expected that DES could substantially reduce restenosis in smaller vessels. Large, randomized studies are warranted to assess the impact of different DESs on outcomes in patients with small coronary arteries.Keywords: small coronary arteries, coronary artery disease, stent, drug-eluting stent, restenosis 

  19. Central venous catheter - flushing

    Science.gov (United States)

    ... during cancer treatment Bone marrow transplant - discharge Central venous catheter - dressing change Peripherally inserted central catheter - flushing Sterile technique Surgical wound care - open Review Date 9/22/2016 Updated by: ...

  20. Identification of cerebral response to balloon distention of the bile duct

    Institute of Scientific and Technical Information of China (English)

    Masafumi; Suyama; Yoshihiro; Kubokawa; Yuuji; Matsumura; Koichi; Inami; Sumio; Watanabe; Eiji; Kirino

    2010-01-01

    AIM: To identify the brain loci that process human biliary sensation. METHODS: In 6 patients (age range: 42-74 years; 4 men), who underwent percutaneous transhepatic biliary drainage (PTBD), the distal biliary tract was stimulated by repeatedly inflating the balloon of the PTBD catheter so that it reached volumes that produced a definite painless sensation. The functional magnetic resonance imaging (fMRI) of the cortical response to biliary sensation was examined. RESULTS: Biliary balloon stimulation elicit...

  1. Treatment of renovascular hypertension by transluminal angioplasty

    DEFF Research Database (Denmark)

    Øvrehus, Kristian A; Andersen, Poul E; Jacobsen, Ib A

    2007-01-01

    OBJECTIVE: The study is a follow-up on treatment of renovascular hypertension (RVH) with percutaneous transluminal renal angioplasty (PTRA). METHODS: Patients were screened on the basis of clinical criteria of increased probability of RVH with renography and in selected cases with renal vein renin...... stable. CONCLUSION: PTRA is an effective treatment of RVH in patients selected by signs of a flow-restricting stenosis. Twelve percent were normotensive after angioplasty and a further 77% had better controlled hypertension. Few complications were seen and renal function was on average unchanged...

  2. Foley Catheters as Temporary Gastrostomy Tubes: Experience of a Nurse-Led Service.

    Science.gov (United States)

    Metussin, Adli; Sia, Rusanah; Bakar, Suriawati; Chong, Vui Heng

    2016-01-01

    Percutaneous endoscopic gastrostomy tube is the modality of choice for long-term enteral nutrition. In the event that replacement tubes are not available, urinary catheters can be used to maintain patency of the gastrostomy tract. This study reports our experience in a nurse-led service using Foley catheters as temporary gastrostomy tubes and the associated complications. Patients who had used Foley catheter as gastrostomy tube over a 2-year period (Jan 2011 to December 2012) were studied. Twenty-one patients had used Foley catheters as a temporary gastrostomy tube, and 12 (57.4%) did not experience any complications, including three patients who were still using Foley catheters at a median of 15 months (range 3-18). Two patients preferred the Foley catheter as feeding tubes. Six patients had replacements with formal balloon replacement tubes, and two patients did not require replacement. Complications occurred in nine (42.6%) patients: repeated burst Foley catheter balloon with peristomal leakage (n = 4), lumen blockage (n = 1), and catheter migration resulting in small bowel obstruction (n = 4). All complications were successfully managed with tube replacements. We showed that in a nurse-led service, using a Foley catheter as a temporary feeding gastrostomy tube is safe, but requires monitoring for complications.

  3. Complex Coronary Interventions with the Novel Mozec™ CTO Balloon: The MOZART Registry.

    Science.gov (United States)

    Lupi, Alessandro; Rognoni, Andrea; Schaffer, Alon; Secco, Gioel G; Bongo, Angelo S

    2015-01-01

    Mozec™ CTO is a novel semicompliant rapid-exchange PTCA balloon catheter with specific features dedicated to treat complex coronary lesions like chronic total occlusions (CTOs). However, no data have been reported about the performance of this device in an all-comers population with complex coronary lesions. We evaluated the safety and success rate of Mozec™ CTO balloon in 41 consecutive patients with chronic stable angina and complex coronary lesions (15 severe calcified coronary stenoses, 15 bifurcation lesions with planned two-stent intervention, and 11 CTOs). Safety was assessed reporting the balloon burst rate after inflation exceeding the rated burst pressure (RBP) according to the manufacturer's reference table. Success was defined as the possibility to advance the device further the target lesion. The Mozec™ CTO balloon showed an excellent performance with a 93.3% success in crossing tight and severely calcified lesions (14/15 pts), a 93.3% success in engaging jailed side branches after stent deployment across bifurcations (14/15 pts), and a 90.9% success in crossing CTO lesions (10/11 pts). The burst rate at RBP of the Mozec™ CTO balloon was 6.7% (1/15 balloons) in the tight and severely calcified lesions, 6.7% (1/15 balloons) when dilating jailed vessels, and 9.1% (1/11 balloons) in CTOs. The novel Mozec™ CTO balloon dilatation catheter showed promising results when employed to treat complex lesions in an all-comers population. Further studies should clarify if this kind of balloon might reduce the need of more costly devices like over-the-wire balloons and microcatheters for complex lesions treatment.

  4. Paclitaxel-coated balloon fistuloplasty versus plain balloon fistuloplasty only to preserve the patency of arteriovenous fistulae used for haemodialysis (PAVE): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Karunanithy, Narayan; Mesa, Irene Rebollo; Dorling, Anthony; Calder, Francis; Katsanos, Konstantinos; Semik, Vikki; Robinson, Emily; Peacock, Janet; Das, Neelanjan; Forman, Colin; Lawman, Sarah; Steiner, Kate; Wilkins, C Jason; Robson, Michael G

    2016-05-12

    The initial therapy for a stenosis in an arteriovenous fistula used for haemodialysis is radiological balloon dilatation or angioplasty. The benefit of angioplasty is often short-lived, intervention-free survival is reported to be 40-50 % at 1 year. Previous small studies and observational data suggest that paclitaxel-coated balloons may be of benefit in improving outcomes after fistuloplasty of stenotic arteriovenous fistulae. We have designed a multicentre, double-blind randomised controlled trial to test the superiority of paclitaxel-coated balloons for preventing restenosis after fistuloplasty in patients with a native arteriovenous fistula. Two hundred and eleven patients will be followed up for a minimum of 1 year. Inclusion criteria include a clinical indication for a fistuloplasty, an access circuit that is free of synthetic graft material or stents, and a residual stenosis of 30 % or less after plain balloon fistuloplasty. Exclusion criteria include a synchronous venous lesion in the same access circuit, location of the stenosis central to the thoracic inlet or a thrombosed access circuit at the time of treatment. The primary endpoint is time to end of target lesion primary patency. This is defined as a clinically-driven radiological or surgical re-intervention at the treatment segment, thrombosis that includes the treatment segment, or abandonment of the access circuit due to an inability to re-treat the treatment segment. Secondary endpoints include angiographic late lumen loss, time to end of access circuit cumulative patency, the total number of interventions, and quality of life. The trial is funded by the National Institute for Health Research. We anticipate that this trial will provide rigorous data that will determine the efficacy of additional paclitaxel-coated balloon fistuloplasty versus plain balloon fistuloplasty only to preserve the patency of arteriovenous fistulae used for haemodialysis. ISRCTN14284759 . Registered on 28 October 2015.

  5. A validation study of a new nasogastric polyfunctional catheter.

    Science.gov (United States)

    Chiumello, D; Gallazzi, E; Marino, A; Berto, V; Mietto, C; Cesana, B; Gattinoni, L

    2011-05-01

    Pleural and abdominal pressure are clinically estimated by measuring the esophageal and bladder or intragastric pressure (IGP), respectively. A new nasogastric polyfunctional catheter is now commercially available, equipped with two balloons in the lower and distal part; this catheter allows simultaneous esophageal pressure (Pes) and IGP measurements and can be also used to feed the patient. We compared the Pes and IGP measured using this new device with those obtained with a standard balloon catheter taken as gold standard. Twenty-four intubated patients requiring ventilator support (mean age 64.3 ± 16.8 years, body mass index 25.3 ± 3.0 kg/m(2), and PaO(2)/FiO(2) 280.8 ± 123.4 mmHg) were enrolled. Esophageal pressure and IGP were measured with the new nasogastric polyfunctional catheter (Nutrivent, Sidam, Italy) and with a standard balloon catheter (Smart Cath Viasys, USA). The Smart Cath was first inserted in the stomach and then retracted to the esophagus to measure IGP and Pes, respectively. In each patient two paired measurements were averaged. In the Bland-Altman analysis, the bias and agreement bands for Pes, ΔPes (computed as the difference of esophageal pressure between end-inspiration and expiration), and IGP were -0.25 (-2.65 to +2.15), 0.0 (-0.9 to +0.9), and -0.45 (-2.85 to + 1.95) cmH(2)O, respectively. No side effects or complications were recorded. The new polyfunctional catheter showed a clinically acceptable validity in recording esophageal and intragastric pressure. This device should help physicians to better individualize the clinical patient management.

  6. Coronary angioplasty for early postinfarction unstable angina

    NARCIS (Netherlands)

    P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); A. Soward; M.J.B.M. van den Brand (Marcel); E. Bos (Egbert); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractCoronary angioplasty was performed in 53 patients in whom unstable angina had reoccurred after 48 hr and within 30 days after sustained myocardial infarction. Single-vessel disease was present in 64% of the patients and multivessel disease in 36%. The preceding myocardial infarction had

  7. "I see the light!" trans-carotid balloon valvuloplasty in neonates and small infants utilizing continuous trans-esophageal echo guidance.

    Science.gov (United States)

    Lucas, Victor

    2015-11-01

    Continuous echo guidance may add to the safety of neonatal aortic balloon valvuloplasty Trans-carotid access is an alternative route to aortic balloon valvuloplasty in neonates Proof of preferred procedure (surgical or catheter based), procedure setting, and access site remains elusive as the disease is infrequent and single center experience remains small.

  8. Second-generation endometrial ablation technologies: the hot liquid balloons.

    Science.gov (United States)

    Vilos, George A; Edris, Fawaz

    2007-12-01

    Hysteroscopic endometrial ablation (HEA) was introduced in the 1980s to treat menorrhagia. Its use required additional training, surgical expertise and specialized equipment to minimize emergent complications such as uterine perforations, thermal injuries and excessive fluid absorption. To overcome these difficulties and concerns, thermal balloon endometrial ablation (TBEA) was introduced in the 1990s. Four hot liquid balloons have been introduced into clinical practice. All systems consist of a catheter (4-10mm diameter), a silicone balloon and a control unit. Liquids used to inflate the balloons include internally heated dextrose in water (ThermaChoice, 87 degrees C), and externally heated glycine (Cavaterm, 78 degrees C), saline (Menotreat, 85 degrees ) and glycerine (Thermablate, 173 degrees C). All balloons require pressurization from 160 to 240 mmHg for treatment cycles of 2 to 10 minutes. Prior to TBEA, preoperative endometrial thinning, including suction curettage, is optional. Several RCTs and cohort studies indicate that the advantages of TBEA include portability, ease of use and short learning curve. In addition, small diameter catheters requiring minimal cervical dilatation (5-7 mm) and short duration of treatment cycles (2-8 min) allow treatment under minimal analgesia/anesthesia requirements in a clinic setting. Following TBEA serious adverse events, including thermal injuries to viscera have been experienced. To minimize such injuries some surgeons advocate the use of routine post-dilatation hysteroscopy and/or ultrasonography to confirm correct intrauterine placement of the balloon prior to initiating the treatment cycle. After 10 years of clinical practice, TBEA is thought to be the preferred first-line surgical treatment of menorrhagia in appropriately selected candidates. Economic modeling also suggested that TBEA may be more cost-effective than HEA.

  9. Ten-year follow-up of percutaneous transluminal coronary angioplasty for proximal left anterior descending coronary artery stenosis in 351 patients.

    Science.gov (United States)

    Ten Berg, J M; Gin, M T; Ernst, S M; Kelder, J C; Suttorp, M J; Mast, E G; Bal, E; Plokker, H W

    1996-07-01

    We sought to evaluate the short- and long-term results of balloon angioplasty for stenoses in the proximal left anterior descending coronary artery. Both the supposedly high rate of acute complications and relatively poor long-term results of balloon angioplasty for stenoses in the proximal left anterior descending coronary artery have led to a search for alternative interventional techniques. We analyzed the success rates and long-term follow-up results in 351 consecutive patients who underwent balloon angioplasty for stenosis of the left anterior descending coronary artery proximal to its first side branch. The power of the study was >80% in detecting a difference of 9% in the proportion of patients who survived at 10 years, assuming an 80% survival rate in the control group. There were 60 ostial and 291 nonostial stenoses. Follow-up lasted a median of 85 months (range 0 to 137) and was 100% complete. The angiographic success rate was 90.9%. The clinical success rate was 86.3%. Nine patients (2.6%) died, 17 (4.8%) needed emergency coronary artery bypass graft surgery, and 10 (2.8%) developed a myocardial infarction. Several patients had subsequent complications. The success and complication rates were not significantly different for patients with ostial and nonostial stenoses. Ten years after balloon angioplasty, freedom from mortality was 80%, freedom from cardiac death was 87%, freedom from myocardial infarction was 84%, freedom from vessel-related reinterventions was 66%, and freedom from angina pectoris was 33%. There were more reinterventions for ostial stenoses, with a 1-year relative risk of ostial versus nonostial stenoses for related reinterventions of 1.7 (95% confidence interval 1 to 2.8, p = 0.049). More than 10 years ago, balloon angioplasty for stenoses in the proximal left anterior descending coronary artery, either ostial or nonostial, had a high success rate. Although the long-term results are satisfactory, ostial stenoses are associated with a

  10. Dealing with stuck hemodialysis catheter: state of the art and tips for the nephrologist.

    Science.gov (United States)

    Forneris, Giacomo; Savio, Daniele; Quaretti, Pietro; Fiorina, Ilaria; Cecere, Pasqualina; Pozzato, Marco; Trogolo, Marco; Roccatello, Dario

    2014-12-01

    The term stuck catheter refers to the condition in which a catheter is not removable from a central vein using standard techniques. Although it is a rare complication, in the last few years it has been reported ever more frequently in hemodialysis due to the widespread use of tunneled catheters. Poor knowledge of the correct procedures and limited experience and training of the specialist in facing this problem are the main reasons for catheter internalization. Stuck catheter is often diagnosed by the nephrologist, who should be competent enough to manage this clinical complication. Among the many options for removing a stuck catheter from the fibrin sleeve, an interventional radiology approach, mainly with endoluminal balloon dilatation, probably provides the best solution. Vascular surgery should be reserved to selected cases in which percutaneous techniques have failed. Nephrologists must play a central role in organizing the treatment of this complication with other specialists in order to avoid making mistakes that may preclude future positive results.

  11. Catheter directed thrombolysis for deep vein thrombosis during the first trimester of pregnancy: two case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kum Rae; Park, Won Kyu; Kim, Jae Woon; Kwun, Woo Hyung; Suh, Bo Yang [College of Medicine, Yeungnam University, Daegu (Korea, Republic of); Park, Kyeong Seok [Yeungnam University, Medical Center, Daegu (Korea, Republic of)

    2008-02-15

    Anticoagulation with heparin has been the standard management therapy of deep vein thrombosis during pregnancy. Pregnancy is generally considered as a contraindication for thrombolysis. However, anticoagulation therapy alone does not protect the limbs from post-thrombotic syndrome and venous valve insufficiency. Catheter-directed thrombolysis, combined with angioplasty and stenting, can remove the thrombus and restore patency of the veins, resulting in prevention of post-thrombotic syndrome and valve insufficiency. We report successful catheter-directed thrombolysis and stenting in two early gestation patients with a deep vein thrombosis of the left lower extremity.

  12. Evaluation of percutaneous transluminal angioplasty for treatment of infrapopliteal arteriosclerosis obliterans%经皮腔内血管成形术治疗膝下动脉粥样硬化闭塞症的评价

    Institute of Scientific and Technical Information of China (English)

    张玉超; 黄英; 李维敏; 陆信武; 黄新天; 陆民; 蒋米尔

    2012-01-01

    Objective To assess the therapeutic effect of percutaneous transluminal angioplasty ( PTA )on the treatment of infrapopliteal arteriosclerosis obliterans( ASOs ). Methods From Jan. 2007 to Jun. 2011, clinical data of patients with infrapopliteal ASO undergoing PTA at our department were retrospectively reviewed. Results Infrapopliteal PTA was performed on 138 lower limbs for 138 patients( mean age,77. 31 ±7. 52 year - old ). The mean diameter of balloon catheters used for infrapopliteal arteries was 2. 8 mm( 2 mm ~4 mm ), with the mean length of 110. 6 mm( 40 mm ~ 170 mm ). There were no severe complications occurring intraoperatively or postoperatively. Early results showed that all patients had significant improvement in ischemic symptoms( 100% ), and no patients had limb loss. During a mean follow -up of 24. 1 months( 4 ~ 58 months ), the rate of improvement in ischemic symptoms for treated limbs was 78. 4% and the limb salvage rate was 93. 9% at 2 years. Conclusion Minimal invasive PTA for the treatment of infrapopliteal ASO is safe and effective for improving ischemic symptoms of lower limbs and limb salvage.%目的 评价经皮腔内血管成形术(percutaneous transluminal angioplasty,PTA)治疗膝下动脉粥样硬化闭塞症(arteriosclerosis obliterans,ASO)的疗效.方法 回顾性研究2007年1月至2011年6月我科收治的累及膝下动脉ASO并行PTA治疗的患者的临床资料.结果 138例患者,平均年龄(77.31±7.52)岁,治疗膝下动脉所用球囊平均直径 2.8mm(2~4mm),平均长度110.6mm(40~170mm),术中及术后无严重并发症.术后早期治疗肢体临床症状明显改善率为100%,无截肢患者.平均随访24.1个月(4~58个月),治疗肢体术后2年临床症状明显改善率78.4%,救肢率93.9%.结论 PTA治疗膝下动脉ASO可有效改善临床缺血症状并提高救肢率.

  13. YC-1 [3-(5'-hydroxymethyl-2'-furyl)-1-benzyl indazole] inhibits neointima formation in balloon-injured rat carotid through suppression of expressions and activities of matrix metalloproteinases 2 and 9.

    Science.gov (United States)

    Liu, Yi-Nan; Pan, Shiow-Lin; Peng, Chieh-Yu; Guh, Jih-Hwa; Huang, Dong-Ming; Chang, Ya-Ling; Lin, Chun-Hung; Pai, Hui-Chen; Kuo, Sheng-Chu; Lee, Fang-Yu; Teng, Che-Ming

    2006-01-01

    Matrix metalloproteinases (MMPs), particularly MMP-2 and MMP-9, and postrevascularization production of vascular smooth muscle cells may play key roles in development of arterial restenosis. We investigated the inhibitory effect of 3-(5'-hydroxymethyl-2'-furyl)-1-benzyl indazole (YC-1), a benzyl indazole compound, on MMP-2 and MMP-9 activity in a balloon-injury rat carotid artery model. Injury was induced by inserting a balloon catheter through the common carotid artery; after 14 days, histopathological analysis using immunostaining and Western blotting revealed significant restenosis with neointimal formation that was associated with enhanced protein expression of MMP-2 and MMP-9. However, these effects were dose-dependently reduced by orally administered YC-1 (1-10 mg/kg). In addition, gelatin zymography demonstrated that increased MMP-2 and MMP-9 activity was diminished by YC-1 treatment. On the other hand, YC-1 inhibited hydrolysis of the fluorogenic quenching substrate Mca-Pro-Leu-Gly-Leu-Dpa-Ala-Arg-NH(2) by recombinant MMP-2 and MMP-9 with IC(50) values = 2.07 and 8.20 muM, respectively. Reverse transcription-polymerase chain reaction analysis of MMP-2 and MMP-9 mRNA revealed that YC-1 significantly inhibited mRNA levels of MMPs. Finally, for the YC-1 treatment group, we did not observe elevation of cGMP levels using enzyme-linked immunosorbent assay, suggesting that YC-1 inhibition of neointimal formation is not through a cGMP-elevating pathway. These data show YC-1 suppression of neointimal formation is dependent on its influence on MMP-2 and MMP-9 protein, mRNA expression, and activity, but not through a cGMP-elevating effect. YC-1 shows therapeutic potential for treatment of restenosis after angioplasty.

  14. Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients

    Science.gov (United States)

    Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young

    2015-01-01

    Purpose The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. Methods We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Results Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all ptamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance. PMID:26263014

  15. Cutting balloon for in-stent restenosis: acute and long-term results.

    Science.gov (United States)

    Rahel, Braim M; Suttorp, Maarten Jan; ten Berg, Jurrien M; Bal, Egbert T; Ernst, Sjef M P G; Rensing, Benno J; Kelder, Johannes C; Plokker, H W Thijs

    2004-08-01

    Conventional percutaneous coronary intervention for the treatment of in-stent restenosis (ISR) has shown a high rate of ISR (30-55%). Considering the need for both extrusion of hyperplastic intima and additional stent expansion, a cutting balloon might be more effective for the treatment of ISR. We prospectively assessed the immediate and 8-month outcome of balloon angioplasty using the Barath Cutting Balloon in 100 consecutive patients (mean age: 60.5 +/- 10.8 years, 71% male). In 73 lesions (73%), a good result was reached with the cutting balloon only. In 21 lesions (21%) postdilatation and in 6 lesions (6%) predilatation with a conventional balloon was necessary. The mean inflation pressure was 8.7 +/- 2.0 (range: 6.0-18.0) atm. Before the procedure the mean minimal luminal diameter (MLD) was 0.95 +/- 0.45 mm. Quantitative coronary analysis showed a mean diameter stenosis of 65%+/- 16%. Immediately after the procedure the mean MLD was 2.42 +/- 0.54 mm with a mean diameter stenosis of 19%+/- 13%. Two patients died during the follow-up period (1 stroke, 1 nonvascular). At 8-month follow-up 26 patients (26%) reported to have anginal complaints CCS class II-IV of whom 16 (16%) needed target lesion revascularization. Treatment of ISR using the Barath Cutting Balloon can be performed safely with good immediate results and a relatively low need for repeated target lesion revascularization at 8-month follow-up.

  16. [Femoral angioplasty. Long-term results].

    Science.gov (United States)

    Foucart, H; Carlier, C; Baudrillard, J C; Joffre, F; Cécile, J P

    1990-01-01

    A study on the long-term efficacy of femoral-popliteal angioplasty was carried out on 185 angioplasty cases over a 5 year follow-up period. A classification of data according to the type of lesion treated, revealed that results were favorable in case of stenosis (87%), short obstruction (70%) and long obstruction (35%). A special study of the outcome of treatments for stage IV arteritis was carried out. After comparing results with those obtained by other teams, the authors list the complications encountered, hematomas, and thromboses, and show their current tendency for regression. Lastly, the authors stress the advantages of angioscopy, which permits to identify the nature of the treated lesions and to predict possible complications, which are usually underrated by angiography.

  17. A pilot study of coronary angioplasty in outpatients.

    OpenAIRE

    Laarman, G.J.; Kiemeneij, F.; van der Wieken, L R; Tijssen, J.G.; Suwarganda, J S; Slagboom, T.

    1994-01-01

    BACKGROUND--Is it safe to discharge patients from hospital on the same day as percutaneous transluminal coronary angioplasty (PTCA)? The hypothesis tested was that careful pre and post angioplasty selection of patients can identify a group that is at very low risk of postprocedural complications and that these patients may be discharged on the day of the procedure. METHODS--63 patients undergoing limited risk coronary angioplasty of 72 lesions were studied. So that patients would be able to w...

  18. Effectiveness of Rehabilitative Balloon Swallowing Treatment on Upper Esophageal Sphincter Relaxation and Pharyngeal Motility for Neurogenic Dysphagia.

    Science.gov (United States)

    Kim, Yong Kyun; Choi, Sung Sik; Choi, Jung Hwa; Yoon, Jeong-Gyu

    2015-08-01

    To investigate the relationship between dysphagia severity and opening of the upper esophageal sphincter (UES), and to assess the effect of balloon size on functional improvement after rehabilitative balloon swallowing treatment in patients with severe dysphagia with cricopharyngeus muscle dysfunction (CPD). We reviewed videofluoroscopic swallowing studies (VFSS) conducted in the Department of Physical Medicine and Rehabilitation, Myongji Hospital from January through December in 2012. All subjects diagnosed with CPD by VFSS further swallowed a 16-Fr Foley catheter filled with barium sulfate suspension for three to five minutes. We measured the maximum diameter of the balloon that a patient could swallow into the esophagus and subsequently conducted a second VFSS. Then, we applied a statistical technique to correlate the balloon diameter with functional improvement after the balloon treatment. Among 283 inpatients who received VFSS, 21 subjects were diagnosed with CPD. It was observed that the degree of UES opening evaluated by swallowing a catheter balloon had inverse linear correlations with pharyngeal transit time and post-swallow pharyngeal remnant. Videofluoroscopy guided iterative balloon swallowing treatment for three to five minutes, significantly improved the swallowing ability in terms of pharyngeal transit time and pharyngeal remnant (p<0.005 and p<0.001, respectively). Correlation was seen between balloon size and reduction in pharyngeal remnants after balloon treatment (Pearson correlation coefficient R=-0.729, p<0.001), whereas there was no definite relationship between balloon size and improvement in pharyngeal transit time (R=-0.078, p=0.738). The maximum size of the balloon that a patient with CPD can swallow possibly indicates the maximum UES opening. The iterative balloon swallowing treatment is safe without the risk of aspiration, and it can be an effective technique to improve both pharyngeal motility and UES relaxation.

  19. Costs and effectiveness of using coumarins before, during and after coronary angioplasty.

    Science.gov (United States)

    ten Berg, Jurrien M; Kelder, Johannas C; Plokker, Thys H W; van Hout, Ben A

    2002-01-01

    In the Balloon Angioplasty and Anticoagulation Study (BAAS), coumarins added to routine aspirin therapy before coronary angioplasty reduced cardiac events at the cost of a slightly higher risk of bleeding complications. To determine the cost effectiveness of coumarin treatment, based on the occurrence of both cardiac and bleeding events. Effectiveness was measured, applying two definitions, in terms of the number of events occurring at one year. In the first definition, the occurrence of death, myocardial infarction (MI), or stroke was assessed. The second definition also included revascularisations and major bleeding episodes as an event. Costs were limited to direct medical costs. Cost effectiveness was addressed by probability ellipses representing the point estimates and uncertainties surrounding both costs and effectiveness. At 1 year, death, MI or stroke occurred 1.1% less often when treating with aspirin plus coumarins rather than aspirin therapy alone. When revascularisations and major bleeding events were also included, the difference was 5.0%. Overall, the additional costs in relation to coumarin treatment were compensated by a reduction in repeat interventions. When including all costs, the savings associated with coumarin treatment were estimated at Euros 235 per patient after 1 year. The probability that coumarins are cost saving was estimated at 0.85. The probability that coumarins combine additional effectiveness with cost savings was estimated at 0.70 when survival free of MI or stroke as an effectiveness measure was considered, and at 0.83 when survival free of MI, stroke, revascularisation or major bleeding was considered. Coumarin therapy added to routine aspirin therapy before coronary angioplasty, and continued during follow-up, may not only be considered more effective but also cost saving relative to aspirin therapy alone.

  20. Short and long term outcomes of primary angioplasty in patients aged 75 years and over

    Directory of Open Access Journals (Sweden)

    Turgay Işık

    2011-06-01

    Full Text Available The treatment of elderly patients with ST segment elevated myocardial infarction (STEMI remains controversial. This study aimed to investigate the effects of primary angioplasty in elderly patients on in-hospital and long term major adverse cardiac events (MACE.Materials and methods: From October 2003 to March 2008, we retrospectively enrolled 220 patients aged 75 years and over with STEMI who underwent primary angioplasty. Patients’ characteristics, in-hospital and long term events were recorded.Results: Male/Female ratio of patients was 129/91 and mean age was 78.7 ± 3.6 (range, 75-97 years, and 58.6% of male. Of these patients 29.2% were diabetics, 69.8% were hypertensive, 34.4% were smoker and 43.5% were anemic at admission. Anterior myocardial infarction was diagnosed in 52.3% of patients. Mean pain-balloon time was 222 ± 116 minutes. Eighty two (38.2% of these 220 patients had three-vessel disease and 12 (5.7% were diagnosed as cardiogenic shock. Procedural success was observed in 79.6% of patients. Heart failure was observed 27.7% in hospital and intra aortic pump was used in 14.5% of patients. There was no significant difference between age groups in long term major cardiac events and in hospital mortality. Diabetes, leukocyte count at admission and in hospital heart failure were independent predictors of short term MACE and low hemoglobin level at admission and peak CKMB levels were independent predictors of long term MACE.Conclusions: Primary angioplasty in patients aged 75 years and over seems to be associated with low procedural complication, high procedural success, improved short and long term survival.

  1. Primary coronary angioplasty for acute myocardial infarction (the Primary Angioplasty Registry).

    Science.gov (United States)

    O'Neill, W W; Brodie, B R; Ivanhoe, R; Knopf, W; Taylor, G; O'Keefe, J; Grines, C L; Weintraub, R; Sickinger, B G; Berdan, L G

    1994-04-01

    During a 14-month period, 6 experienced centers prospectively enrolled 271 patients into a registry in which percutaneous transluminal coronary angioplasty was the primary treatment for acute myocardial infarction. Patients age > 18 years who presented with ST-segment elevation on the 12-lead electrocardiogram were enrolled if symptom duration was or = 2 units of blood occurred in 46 patients (18%); 14 of these transfusions were related to coronary artery bypass surgery. Primary angioplasty is associated with a high reperfusion rate, low in-hospital mortality and few recurrent myocardial ischemic events. These results point to the need for a large-scale trial comparing angioplasty with thrombolytic therapy in the setting of acute myocardial infarction.

  2. Universal stratospheric balloon gradiometer

    Science.gov (United States)

    Tsvetkov, Yury; Filippov, Sergey; Brekhov, Oleg; Nikolaev, Nikolay

    The study of the interior structure of the Earth and laws of its evolution is one of the most difficult problems of natural science. Among the geophysical fields the anomaly magnetic field is one of the most informational in questions of the Earth’s crust structure. Many important parameters of an environment are expedient for measuring at lower altitudes, than satellite ones. So, one of the alternatives is stratospheric balloon survey. The balloon flight altitudes cover the range from 20 to 50 km. At such altitudes there are steady zone air flows due to which the balloon flight trajectories can be of any direction, including round-the-world (round-the-pole). For investigation of Earth's magnetic field one of the examples of such sounding system have been designed, developed and maintained at IZMIRAN and MAI during already about 25 years. This system consists of three instrumental containers uniformly placed along a vertical 6 km line. Up today this set has been used only for geomagnetic purposes. So we describe this system on example of the measuring of the geomagnetic field gradient. System allows measuring a module and vertical gradient of the geomagnetic field along the whole flight trajectory and so one’s name is - stratospheric balloon magnetic gradiometer (SMBG). The GPS-receivers, located in each instrumental container, fix the flight coordinates to within several tens meters. Process of SBMG deployment, feature of the exit of rope from the magazine at the moment of balloon launching has been studied. Used magazine is cellular type. The hodograph of the measuring base of SBMG and the technique of correction of the deviations of the measuring base from the vertical line (introduction of the amendments for the deviation) during the flight have been investigated. It is shown that estimation of the normal level of values of the vertical gradient of the geomagnetic field is determined by the accuracy of determining the length of the measuring base SBMG

  3. Mars Solar Balloon Lander Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  4. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  5. Balloon dacryocystoplasty: Incomplete versus complete obstruction of the nasolacrimal system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Lee, Sang Hoon; Han, Young Min; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul [Chung Ang University College of Medicine, Seoul (Korea, Republic of); Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1993-07-15

    Balloon dilatation of nasolacrimal drainage apparatus was attempted for the treatment of stenoses or obstructures of the nasolacrimal system in 49 eyes of 41 consecutive patients with complete obstructions and 16 eyes of 14 patients with incomplete obstructions. These two groups were compared with regards to the effectiveness of balloon dacryocystoplasty. All patients suffered from severe epiphora had already undergone multiple probings. A 0.018 inch hair or ball guide wire was introduced through the superior punctum into the inferior meatus of the nasal cavity and pulled out through the nasal aperture using a hemostat under nasal endoscopy. A deflated angiography balloon catheter was then introduced in a retrograde direction and dilated under fluoroscopic control. No major complications occurred in any of the patients. At 7 days after balloon dilatation, 25 of 49 eyes with complete obstruction demonstrated improvement in epiphora (initial success rate: 51.0%) and among them 17 eyes showed complete resolution of symptoms. Reocclusion occurred in 12 of the 25 eyes with initial improvement at the 2 months follow up. For the 16 eyes with incomplete obstruction, and improvement of epiphora was attained in 11 eyes (initial success rate 68.8%): 5 of these eyes showed complete resolution of epiphora, and 3 was failed to maintain initial improvement at the 2 month follow up. Although this study demonstrate that results of balloon dacryocystoplasty are not encouraging because of the high failure and recurrence rate, balloon dacryocystoplasty is a simple and safe nonsurgical technique that can be used to treat for obstructions of the nasolacrimal system. In addition, balloon dacryocystoplasty shows better results in incomplete obstruction than in complete obstruction than complete obstruction of the nasolacrimal system.

  6. Indwelling urethral catheters in adults

    OpenAIRE

    Calleja, Edward

    2012-01-01

    This article focuses on indwelling urethral catheters in adults, their indications for the short and long term use, the types of urinary catheters available in Malta, an overview of the basic structure of a catheter, and the complications of urinary catheter insertion and maintenance. An attempt has been made to address in some depth the most common complication of indwelling catheterscatheter associated urinary tract infection in terms of pathophysiology and its management. Simple but cru...

  7. [Baloon angioplasty with stent implantation in recoarctation of the aorta: an attractive alternative].

    Science.gov (United States)

    Saliba, Z; Aggoun, Y; Iserin, L; Massih, T A; Bonnet, D; Acar, P; Mousseaux, E; Sidi, D; Kachaner, J; Bonhoeffer, P

    2001-05-01

    The results of transcatheter balloon angioplasty in teenagers and adults with aortic recoarctation are uncertain. Therefore, there is a current trend to prefer a more complex procedure including the implantation of a stent. This study deals with 8 patients aged 7 to 25.3 years (median: 15 years), weighing 20 to 68 kg. (median: 57) and having undergone resection of an aortic coarctation during infancy (24 days to 4 years). All had their lower limb pulses diminished or abolished, elevated blood pressure at rest (and at exercise in the 5 tested patients), and left ventricular hypertrophy. MRI documented the lesion and helped to select seven patients whose stenosis was short and remote enough from the origin of the main aortic collateral. In one case, the decision to stent was taken as an emergent measure to treat an aortic dissection which appeared shortly after balloon dilatation. The effectiveness of the procedure was immediate in all patients with a 50% increase in diameter of the dilated area, total relief of the gradient, drop to normal values of the blood pressure. These good results persisted at follow-up (3-24 months) in 6 patients, with moderate hypertensive rebounds in the last 2. There were 2 technical problems (premature burst of the balloon, asymmetrical inflation of the stent like an "Eiffel Tower") that could finally be overcome and should no longer occur with the new specially designed so-called "BIB" balloons. Would long term follow-up confirm these early results, one should conclude that this method offers an attractive, safe and effective option to surgery for adolescents and adults with late recoarctation of the aorta.

  8. Development of novel short-term heating angioplasty: thermal denaturation dynamics of collagen in artery wall

    Science.gov (United States)

    Shimazaki, N.; Tokunaga, H.; Katou, Y.; Hayashi, T.; Arai, T.

    2009-02-01

    We have studied to develop the new thermal angioplasty methodology, photo-thermo dynamic balloon angioplasty (PTDBA), which provides artery dilatation with short-term (collagen in artery media may be the important factor to attain sufficient artery dilatation for the PTDBA. In order to predict the optimum heating condition i.e. the balloon temperature and heating duration, we investigated the thermal denaturation dynamics of artery collagen in ex vivo. The extracted fresh porcine carotid artery was used. The temperature-dependent light scattering property and mechanical property of the artery specimen were simultaneously measured during artery temperature rising by specially made setup to assess the denaturation of arterial collagen. The change rate of the backscattered light intensity from the artery specimen; I(T)/I0 with 633nm was measured to evaluate the artery scattering property change with the thermal denaturation. The artery specimen was heated from 25°C to 80°C with constant temperature rising rate of 3°C/min. The measured I(T)/I0 was suddenly increased over 48°C. This boundary temperature might be the initiation temperature of the arterial collagen denaturation. We defined the variation of the I(T)/I0 as the collagen denaturation ratio, and calculated the reactive enthalpy by the chemical equilibrium theory. Since the calculated enthalpy was similar to the enthalpy in literature report, the variety of I(T)/I0 during the temperature rising might be attributed to the collagen conformational change due to the denaturation. In terms of the artery internal force measurement, the artery force was decreased with increasing of the artery temperature up to 65°C (i.e. softening), and increased over 65°C (i.e. shrinkage). We confirmed that the changes of the backscattered light (at 633nm in wavelength) from the artery might represent the artery collagen thermal denaturation degree.

  9. How does subintimal angioplasty compare to transluminal angioplasty for the treatment of femoral occlusive disease?

    Science.gov (United States)

    Klimach, S G; Gollop, N D; Ellis, J; Cathcart, P

    2014-01-01

    A best evidence topic in surgery was written according to a structured protocol. The question addressed how subintimal angioplasty (SIA) compares to transluminal angioplasty (TA) for the treatment of femoral occlusive disease. One hundred and thirty two papers were found using the reported search; the 5 which represented the best evidence to answer the question are discussed. The evidence on this subject is limited; there are no randomised controlled trials (RCTs) comparing SIA to TA for pathologically equivalent lesions. However SIA remains a safe and effective alternative to surgical bypass grafting when TA cannot be performed.

  10. [The bladder catheter].

    Science.gov (United States)

    Pestalozzi, D M

    1996-09-01

    The benefit of the transurethral catheter to protect or measure renal function is well accepted. Urethral stricture and infection of the lower urinary tract as the complications should lead to a cautious use of catheters. A careful placement, the choice of the best material and a correct management help to avoid complications. Alternatives are discussed.

  11. [Complications of transluminal coronary angioplasty. A multicenter French study (1983)].

    Science.gov (United States)

    Valeix, B; Labrunie, P; Marco, J; Cherrier, F; Cuillière, M; Bertrand, M; Schmitt, R; Sabatier, M; Gaspard, P; Guermonprez, J L

    1985-03-01

    The authors report the complications observed during 1 247 transluminal coronary angioplasties (TCA) performed in 1 187 patients in 17 french centers between 1979 and October 1983. There were 855 primary successes (68.9 p. 100). There were 41 cases of symptomatic dissection (3.3 p. 100) of which 32 underwent aortocoronary bypass surgery with a residual myocardial infarction (MI) in 13 cases (40.6 p. 100). Medical treatment of symptomatic dissection gave very poor results (7 out of 9 MI) and is formally contra-indicated. 67 per- or postoperative occlusions were observed (5.3 p. 100). This is the most serious complication which necessitates an emergency revascularisation procedure (TCA or coronary bypass surgery--CBS--) because MI rapidly follows in patients without a well-developed collateral circulation. In this series MI occurred in 28 out of 45 patients--62 p. 100--despite CBS. This underlines the value of an immediate repeat TCA which, when successful, results in a much faster revascularisation. Seventy-three MI (5.8 p. 100) were observed in the first 24 hours: 50 p. 100 were secondary to an angiographically documented coronary occlusion. The other two causes were coronary dissection and spasm. Emergency CBS was carried out in 107 cases (8.9 p. 100) mainly for coronary occlusion or symptomatic dissection. The mortality was 11 out of 1 187 patients (0.93 p. 100). Death occurred in the catheter laboratory in 3 cases, during the first 24 hours in the operating theatre in 1 case, and after the first 24 hours but before hospital discharge in 7 patients.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Percutaneous Transluminal Angioplasty in Patients with Peripheral Arterial Disease Does Not Affect Circulating Monocyte Subpopulations

    Directory of Open Access Journals (Sweden)

    Pawel Maga

    2016-01-01

    Full Text Available Monocytes are mononuclear cells characterized by distinct morphology and expression of CD14 and CD16 surface receptors. Classical, quiescent monocytes are positive for CD14 (lipopolysaccharide receptor but do not express Fc gamma receptor III (CD16. Intermediate monocytes coexpress CD16 and CD14. Nonclassical monocytes with low expression of CD14 represent mature macrophage-like monocytes. Monocyte behavior in peripheral arterial disease (PAD and during vessel wall directed treatment is not well defined. This observation study aimed at monitoring of acute changes in monocyte subpopulations during percutaneous transluminal angioplasty (PTA in PAD patients. Patients with Rutherford 3 and 4 PAD with no signs of inflammatory process underwent PTA of iliac, femoral, or popliteal segments. Flow cytometry for CD14, CD16, HLA-DR, CD11b, CD11c, and CD45RA antigens allowed characterization of monocyte subpopulations in blood sampled before and after PTA (direct angioplasty catheter sampling. Patients were clinically followed up for 12 months. All 61 enrolled patients completed 12-month follow-up. Target vessel failure occurred in 12 patients. While absolute counts of monocyte were significantly lower after PTA, only subtle monocyte activation after PTA (CD45RA and β-integrins occurred. None of the monocyte parameters correlated with long-term adverse clinical outcome. Changes in absolute monocyte counts and subtle changes towards an activation phenotype after PTA may reflect local cell adhesion phenomenon in patients with Rutherford 3 or 4 peripheral arterial disease.

  13. Crossing the bends: Support-catheter based left ventricular lead placement in challenging cardiac resynchronization therapy device implantation

    Directory of Open Access Journals (Sweden)

    Amit Kumar Malik, MBBS, MD

    2012-08-01

    Full Text Available The combined use of an Amplatz guiding catheter and support catheter creates a progressively supportive rail to implant the left ventricular (LV lead in difficult cardiac resynchronization therapy device implantation. We describe the case of a 32-year-old male with non-ischaemic cardiomyopathy, left bundle-branch block, and an LV ejection fraction of 30%, who was referred to our centre for a repeat attempt at an LV lead implant. Previously, the implanter had been unable to advance different guide catheters over the wire to the desired tributary of the coronary sinus (CS. At our centre, the CS was cannulated with a 6-Fr AL2 coronary guiding catheter. A 135-cm support catheter (Spectranetics Quick-Cross was advanced via AL2 guiding over the 0.035 in. guide wire to the distal CS. The proximal luer fitting of the support catheter was cut and an inner sheath (Medtronic ATTAIN SELECT II advanced over the support catheter into the CS. A 4-Fr over-the-wire LV lead was advanced through the inner sheath over a 0.014 in. percutaneous transluminal coronary angioplasty wire after removal of the support catheter. The use of a support catheter serves as rail for the placement of the inner sheath deep in the CS and facilitates implantation of the LV pacing lead. This technique is safe and easily applied.

  14. Ballon angioplasty and stenting for acute ischemic stroke%急性缺血性卒中患者的球囊血管成形和支架置入术治疗

    Institute of Scientific and Technical Information of China (English)

    石明超; 王守春

    2009-01-01

    药物溶栓治疗急性缺血性卒中存在一定的局限性,球囊血管成形和支架置入术已成为急性缺血性卒中治疗的研究热点.文章综述了球囊血管成形和支架置入术治疗急性缺血性卒中的有效性和安全性.%Thrombolytic agents for the treatment of acute ischemic stroke have some limitations. Balloon angioplasty and stenting have become the research hotspot in the treatment of acute ischemic stroke. 1his article reviews the effectiveness and safety of balloon angioplasty and stenting in the treatment of acute ischemic stroke.

  15. Oral anticoagulant therapy during and after coronary angioplasty the intensity and duration of anticoagulation are essential to reduce thrombotic complications.

    Science.gov (United States)

    ten Berg, J M; Hutten, B A; Kelder, J C; Verheugt, F W; Plokker, H W

    2001-04-24

    In the randomized Balloon Angioplasty and Anticoagulation Study (BAAS), the addition of oral anticoagulants to aspirin significantly reduced early and late events after coronary angioplasty. However, bleeding episodes were increased. The present report studied the intensity and the duration of anticoagulation as predictors of thrombotic and bleeding events. A total of 530 patients, 34% of whom received a stent, were treated with aspirin plus coumarins. Half of the patients were randomized to angiographic follow-up. The target international normalized ratio (INR) was 2.1 to 4.8 during angioplasty and 6-month follow-up. Thrombotic events were death, myocardial infarction, target lesion revascularization, and thrombotic stroke. Bleeding complications were hemorrhagic stroke, major extracranial bleeding, and false aneurysm. "Optimal" anticoagulation was defined as an INR in the target range for at least 70% of the follow-up time. There were 17 early thrombotic events (3.2%), 7 early bleeding episodes (1.3%), and 10 false aneurysms (1.9%). The incidence rate for both early thrombotic and bleeding events was lowest in patients in the target range. A total of 61 late thrombotic events occurred (11.6%). Optimal anticoagulation was an independent predictor of late thrombotic events (relative risk, 0.33; 95% CI, 0.19 to 0.57) and was associated with a 0.21 mm (95% CI, 0.17 to 0.42) larger vessel lumen at 6 months. Late bleeding episodes (1.4%) were lowest in patients in the target range. Coumarins started before coronary angioplasty with a target INR of 2.1 to 4.8 led to the lowest procedural event rate, without an increase in bleeding episodes. During follow-up, optimal anticoagulation was associated with a decrease in the incidence of late events by 67% and a significant improvement in 6-month angiographic outcome.

  16. Efficacy and safety of venous angioplasty of the extracranial veins for multiple sclerosis. Brave dreams study (brain venous drainage exploited against multiple sclerosis: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Zamboni Paolo

    2012-10-01

    Full Text Available Abstract Background Multiple sclerosis (MS is a chronic inflammatory demyelinating disease of the central nervous system with a disabling progressive course. Chronic cerebrospinal venous insufficiency (CCSVI has recently been described as a vascular condition characterized by restricted venous outflow from the brain, mainly due to blockages of the internal jugular and azygos veins. Despite a wide variability among studies, it has been found to be associated with MS. Data from a few small case series suggest possible improvement of the clinical course and quality of life by performing percutaneous balloon angioplasty (PTA of the stenotic veins. Study design and methods This is a multicenter, randomized, parallel group, blinded, sham-controlled trial to assess the efficacy and safety of PTA. Participants with relapsing remitting MS or secondary progressive MS and a sonographic diagnosis of CCSVI will be enrolled after providing their informed consent. Each participant will be centrally randomized to receive catheter venography and PTA or catheter venography and sham PTA. Two primary end points with respect to efficacy at 12 months are (1 a combined end point obtained through the integration of five functional indicators, walking, balance, manual dexterity, bladder control, and visual acuity, objectively measured by instruments; and (2 number of new brain lesions measured by T2-weighted MRI sequences. Secondary end points include annual relapse rate, change in Expanded Disability Status Scale score, proportion of patients with zero, one or two, or more than two relapses; fatigue; anxiety and depression; general cognitive state; memory/attention/calculus; impact of bladder incontinence; and adverse events. Six hundred seventy-nine patients will be recruited. The follow-up is scheduled at 12 months. Patients, treating neurologists, trained outcome assessors, and the statistician in charge of data analysis will be masked to the assigned treatment

  17. Carotid angioplasty and stenting in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Kadkhodayan, Yasha [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Cross, DeWitte T.; Moran, Christopher J. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Derdeyn, Colin P. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States)

    2007-11-15

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients {<=}79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  18. Early development of bacterial community diversity in emergently placed urinary catheters

    Directory of Open Access Journals (Sweden)

    Foxman Betsy

    2012-06-01

    Full Text Available Abstract Background Approximately 25% of hospitalized patients have a urinary catheter, and catheter associated urinary tract infection is the most common nosocomial infection in the US, causing >1 million cases/year. However, the natural history of the biofilms that rapidly form on urinary catheters and lead to infection is not well described. Findings We characterized the dynamics of catheter colonization among catheters collected from 3 women and 5 men in a trauma burn unit with different indwelling times using TRFLP and culture. All patients received antibiotic therapy. Results: Colony-forming units increased along the extraluminal catheter surface from the catheter balloon to the urethra, but no trend was apparent for the intraluminal surface. This suggests extraluminal bacteria come from periurethral communities while intraluminal bacteria are introduced via the catheter or already inhabit the urine/bladder. Richness of operational taxonomic units (OTUs increased over time on the intraluminal surface, but was constant extraluminally. Conclusions OTU community composition was explained best by time rather than axial location or surface. Our results suggest that catheter colonization can be very dynamic, and possibly have a predictable succession.

  19. Primary coronary angioplasty in a nonagenarian

    Directory of Open Access Journals (Sweden)

    Baracioli Luciano M.

    2002-01-01

    Full Text Available A woman aged 98 years entered the tertiary hospital service with a picture of acute myocardial infarction of the extensive anterior wall, which began 4 hours earlier. Due to the large myocardial risk area suggested by the electrocardiogram, the patient was taken to the hemodynamics laboratory for the performance of emergency coronary arteriography, which revealed occlusion in the proximal third of the anterior descending artery. Primary angioplasty followed by stent grafting was successfully performed. The patient had a satisfactory evolution (Killip I and was discharged from the hospital on the seventh postinfarction day. We discuss here aspects of thrombolysis and coronary percutaneous interventions in the aged.

  20. Characteristics of smooth muscle cells' shape and proliferation rate in novel short-term thermal angioplasty ex vivo and in vitro.

    Science.gov (United States)

    Kunio, Mie; Shimazaki, Natsumi; Ito, Arisa; Hayashi, Tomoaki; Arai, Tsunenori

    2010-01-01

    We investigated the influences on the smooth muscle cells of temporally heated arterial walls in both ex vivo and in vitro study to determine the optimum heat parameter of novel short-term thermal angioplasty, Photo-thermo Dynamic Balloon Angioplasty (PTDBA). Arterial heating dilatation was performed by the prototype PTDBA balloon ex vivo. We found that the smooth muscle cells in the vessel wall were stretch-fixed after the heating dilatation ex vivo. The stretch-fixing rate of these cells was increased with the temperature rise in the balloon of PTDBA from 60 °C to 70 °C. We measured the proliferation rate of the stretch-fixed smooth muscle cells, which were extracted from porcine arteries, on specially designed culture equipment in vitro. It was observed that the proliferation rate was inhibited at 20 % stretching compared to 10 % stretching. We think the stretch-fixing of the smooth muscle cells might not be harmful for PTDBA performances.

  1. Suprapubic catheter care

    Science.gov (United States)

    ... urine bag only a few times a day. Caring for Your Skin Near your Catheter Follow these ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated: ...

  2. Intrauterine balloon tamponade for the control of postpartum haemorrhage.

    Science.gov (United States)

    Lohano, Rajni; Haq, Gulfishan; Kazi, Sarah; Sheikh, Saima

    2016-01-01

    To evaluate the effectiveness of balloon temponade in the management of postpartum haemorrhage. The study was conducted at the Dow University of Health Sciences and Civil Hospital Karachi from January to July 18, 2012, and comprised women aged 18-35 years, parity 1-6 and gestational age 31-41 weeks, who developed or were admitted with primary postpartum haemorrhage due to uterine atony in whom medical treatment had failed. SPSS 10 was used to analyse the data. The mean age, parity, gestational age of 139 women was 26.4±4.2 years, 3.4±1.3, 37.81±1.67 respectively. Mean estimated blood loss was 1155.8±350.6 ml, mean systolic blood pressure 90.96±18.1 mmHg, diastolic blood pressure 55±7.5 mmHg and mean pulse was 108.3±10.89 bpm. Balloon tamponade was effective in 126(90.4%) cases. Condom catheter balloon tamponade was an effective means of controlling postpartum haemorrhage. There should be a low threshold for use of balloon tamponade as it is effective, easy to use, easily available, has low complication rate, and an inexpensive modality to manage non-traumatic postpartum haemorrhage, especially in resource-limited settings, and still maintain reproductive ability.

  3. Obesity and gastric balloon

    Directory of Open Access Journals (Sweden)

    Mohammed I Yasawy

    2014-01-01

    Full Text Available Background: The obesity epidemic, which is among the most common nutritional disorders, is rising rapidly worldwide. It leads to several health problems such as metabolic disorders, stroke, and even cancer. Efforts to control obesity with exercise and diet have a limited value in obese patients and different approaches to do this have been tried. In this paper, we share our experience with bioenteric intragastric balloon (BIB in treating obesity: Its safety, tolerability, and its efficacy in weight reduction. Materials and Methods: From January 2009 to September 2012, a total of 190 gastric balloons was inserted on patients at the endoscopy unit in King Fahd Hospital of the University, Al-Khobar. This is an evaluation of the first 100 patients. All the patients had a body mass index of over 30 kg/m 2 and were within the age range of 17-55 with a mean age of 32 years. After consent, preballoon investigation tests and anesthesia evaluation, BIB was inserted under monitored anesthesia care sedation in the endoscopy suite. The balloon was filled with 500-700 mls of stained saline. All patients′ were given an analgesic and antiemetic for a week and antisecretory proton pump inhibitor′s for 6 months. Diet and the importance of the exercise were part of the preballoon insertion phase and protocol. The balloon was removed after 6-12 months. Results: The weight loss response to BIB in the 100 patients are classified into four groups: In the uncooperative, noncompliant patients - the maximum weight loss was 7 kg, while in the most compliant patients the weight loss reached up to 39 kg. In addition, there was significant improvement into diabetes mellitus, hypertension, dyslipidemia, and fatty liveras. Its safety and tolerability were extremely acceptable. Conclusion: Our data indicates that in well-selected patients, BIB is an effective device, which with minimum complications helps to achieve body weight loss and resolve many obesity related

  4. NASA Super Pressure Balloon

    Science.gov (United States)

    Fairbrother, Debbie

    2017-01-01

    NASA is in the process of qualifying the mid-size Super Pressure Balloon (SPB) to provide constant density altitude flight for science investigations at polar and mid-latitudes. The status of the development of the 18.8 million cubic foot SPB capable of carrying one-tone of science to 110,000 feet, will be given. In addition, the operating considerations such as launch sites, flight safety considerations, and recovery will be discussed.

  5. Space Weather Ballooning

    Science.gov (United States)

    Phillips, Tony; Johnson, Sam; Koske-Phillips, Amelia; White, Michael; Yarborough, Amelia; Lamb, Aaron; Herbst, Anna; Molina, Ferris; Gilpin, Justin; Grah, Olivia; Perez, Ginger; Reid, Carson; Harvey, Joey; Schultz, Jamie

    2016-10-01

    We have developed a "Space Weather Buoy" for measuring upper atmospheric radiation from cosmic rays and solar storms. The Buoy, which is carried to the stratosphere by helium balloons, is relatively inexpensive and uses off-the-shelf technology accessible to small colleges and high schools. Using this device, we have measured two Forbush Decreases and a small surge in atmospheric radiation during the St. Patrick's Day geomagnetic storm of March 2015.

  6. A refinement of Hong's technique for the removal of stuck dialysis catheters: an easy solution to a complex problem.

    Science.gov (United States)

    Quaretti, Pietro; Galli, Franco; Fiorina, Ilaria; Moramarco, Lorenzo Paolo; Spina, Monica; Forneris, Giacomo; Torresi, Mario; Bellazzi, Roberto

    2014-01-01

    A long-term tunneled hemodialysis catheter can be difficult or impossible to pull out if a fibrin sleeve has attached it to the venous wall. We report the outcome of a refinement of Hong's technique for removing incarcerated catheters aimed at improving its feasibility and safety. We applied a modification of Hong's technique in four patients (two males, age ranging from 51 to 68 years) with jugular twin hemodialysis catheters (five of eight lines incarcerated). Hong pioneered the technique of endoballooning to expand a stuck central venous catheter, thus freeing it from adhesions. In our technical refinement, we cut the catheter close to its venous entry point in order to facilitate pullout and inserted a valved introducer as access for guide wires as well as for inflations of the catheter balloon. A stiff guide wire was placed in the inferior vena cava to avoid potential damage to heart cavities. Dilation was monitored under fluoroscopy with constrictions showing points where the catheter was incarcerated. If adhesions persisted through the same introducer, endoluminal dilations were repeated with a larger diameter balloon until the catheter was released. New catheters can be positioned using the stiff guide wire already in place. All removals were carried out under local anesthesia in an angiographic room by interventional radiologists. All catheters were successfully removed without complications. Average fluoroscopy time for removal was 12 minutes. In the case of a Tesio catheter removed after 12 years because of infection, a computed tomography scan 2 months later revealed persistence of a calcified fibrin sleeve in the vessel. Hong's technique was confirmed to be a simple, safe and highly effective way to remove incarcerated long-term central venous catheters. The refinements we adopted made the procedure more flexible and possibly less prone to complications. By properly using ordinary tools available anywhere, Hong's technique could be considered Columbus

  7. Outpatient coronary angioplasty: feasible and safe.

    Science.gov (United States)

    Slagboom, Ton; Kiemeneij, Ferdinand; Laarman, Gert Jan; van der Wieken, Ron

    2005-04-01

    This study tested the safety and feasibility of coronary angioplasty on an outpatient basis. The purpose of this approach includes cost-effectiveness and patient comfort. Six hundred forty-four patients were randomized to either transradial or transfemoral PTCA using 6 Fr equipment. Patients were triaged to outpatient management based on a predefined set of predictors of an adverse outcome in the first 24 hr after initially successful coronary angioplasty. Three hundred seventy-five patients (58%) were discharged 4-6 hr after PTCA; 42% stayed in hospital overnight. In the outpatient group, one adverse event occurred (subacute stent thrombosis 7 hr postdischarge, nonfatal myocardial infarction). There were no major vascular complications. In the hospital group, 19 patients (7%) sustained an adverse cardiac even in the first 24 hr; 1 patient died. Patients treated via the femoral route had more (minor) bleeding complications (19 patients; 6%); in 17 of these, this was the sole reason that discharge was delayed. PTCA on an outpatient basis, performed via the radial or the femoral artery with low-profile equipment, is safe and feasible in a considerable part of a routine PTCA population. A larger proportion of transradial patients can be discharged due to a reduction in (minor) bleeding complications.

  8. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    Energy Technology Data Exchange (ETDEWEB)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de; Kurre, Wiebke, E-mail: w.kurre@klinikum-stuttgart.de [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany); Schmid, Elisabeth, E-mail: ESchmid@klinikum-stuttgart.de; Baezner, Hansjoerg, E-mail: H.Baezner@klinikum-stuttgart.de [Klinikum Stuttgart, Klinik fuer Neurologie, Neurozentrum (Germany); Henkes, Hans, E-mail: hhhenkes@aol.com [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany)

    2013-04-15

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  9. Breakthrough in Mars balloon technology

    Science.gov (United States)

    Kerzhanovich, V. V.; Cutts, J. A.; Cooper, H. W.; Hall, J. L.; McDonald, B. A.; Pauken, M. T.; White, C. V.; Yavrouian, A. H.; Castano, A.; Cathey, H. M.; Fairbrother, D. A.; Smith, I. S.; Shreves, C. M.; Lachenmeier, T.; Rainwater, E.; Smith, M.

    2004-01-01

    Two prototypes of Mars superpressure balloons were flight tested for aerial deployment and inflation in the Earth's stratosphere in June, 2002. One was an 11.3 m diameter by 6.8 m high pumpkin balloon constructed from polyethylene film and Zylon (PBO) tendons, the second was a 10 m diameter spherical balloon constructed from 12 μm thick Mylar film. Aerial deployment and inflation occurred under parachute descent at 34 km altitude, mimicing the dynamic pressure environment expected during an actual Mars balloon mission. Two on-board video cameras were used on each flight to provide real-time upward and downward views of the flight train. Atmospheric pressure and temperature were also recorded. Both prototypes successfully deployed from their storage container during parachute descent at approximately 40 m/s. The pumpkin balloon also successfully inflated with a 440 g charge of helium gas injected over a 1.5-min period. Since the helium inflation system was deliberately retained after inflation in this test, the pumpkin balloon continued to fall to the ocean where it was recovered for post-flight analysis. The less robust spherical balloon achieved only a partial (~70%) inflation before a structural failure occurred in the balloon film resulting in the loss of the vehicle. This structural failure was diagnosed to result from the vigorous oscillatory motion of the partially inflated balloon, possibly compounded by contact between the balloon film and an instrumentation box above it on the flight train. These two flights together represent significant progress in the development of Mars superpressure balloon technology and pave the way for future flight tests that will include post-deployment flight of the prototype balloons at a stable altitude.

  10. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  11. Treatment of pacemaker-induced superior vena cava syndrome by balloon angioplasty and stenting.

    LENUS (Irish Health Repository)

    Klop, B

    2011-01-01

    Superior vena cava (SVC) syndrome is a rare but serious complication after pacemaker implantation. This report describes three cases of SVC syndrome treated with venoplasty and venous stenting, with an average follow-up of 30.7 (±3.1) months. These cases illustrate that the definitive diagnosis, and the extent and location of venous obstruction, can only be determined by venography.

  12. Comparative quantitative angiographic analysis of directional coronary atherectomy and balloon coronary angioplasty

    NARCIS (Netherlands)

    A.W.M. Umans (A. W M); K.J. Beatt (Kevin); B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1991-01-01

    markdownabstract__Abstract__ An attempt to assess the “utility” of directional atherectomy was made using a new quantitative angiographic index. This index can be subdivided into an initial gain component and a restenosis component. The initial gain index is the ratio between the gain in diameter d

  13. Balloon Angioplasty and Drug Eluting Stenting for Treatment of Peripheral Arterial Occlusive Disease

    Directory of Open Access Journals (Sweden)

    Akın İzgi

    2010-08-01

    Full Text Available Peripheral arterial disease is one of the manifestations of systemic atherosclerosis. In the last decade, remarkable technological advances, especially in the stent area, have shifted revascularization strategies from traditional open surgical approaches toward less morbide percutaneous endovascular treatments. However, even with new designed nitinol bare stents, restenosis remains as the major obstacle of this procedures. More recently, drug eluting stent platforms have been used to treat atherosclerotic peripheral arterial disease. In this article, we reviewed new studies relevant to drug eluting stents for lower extremity peripheral arterial occlusive disease.

  14. [Reintervention with percutaneous balloon angioplasty in patients with congenital heart disease with left-sided obstructions].

    Science.gov (United States)

    Márquez-González, Horacio; López-Gallegos, Diana; Pérez-Velázquez, Nataly Alejandra; Yáñez-Gutiérrez, Lucelli

    2017-01-01

    Introducción: las obstrucciones izquierdas representan 15% de las cardiopatías congénitas (CC). El tratamiento en la edad adulta es quirúrgico; no obstante, la dilatación con balón puede paliar los síntomas en edad pediátrica para permitir que alcancen la talla diana. El objetivo fue determinar la sobrevida y los factores asociados a la reintervención en enfermos con CC con obstrucción izquierda tratados con plastía con balón. Métodos: se realizó un estudio de cohorte en pacientes entre 4 y 17 años con cardiopatías de obstrucción izquierda (estenosis valvular, supravalvular y coartación aórtica) tratados con angioplastía con balón exitosa. El seguimiento fue de 10 años y la variable de desenlace fue la reestenosis con criterios para reintervención. Se consideraron variables pronósticas la etapa pediátrica al momento del procedimiento, el estado nutricional, el gradiente residual y la presencia de síndromes genéticos. Se usaron medidas de tendencia central y dispersión. Se usó chi cuadrada en variables cualitativas y Kruskal-Wallis en variables cuantitativas. Resultados: fueron 110 pacientes; 40% presentó coartación aórtica, 35% estenosis valvular y 25% estenosis supravalvular aórtica. El 39% requirió reintervención y la frecuencia fue la siguiente: 80% en estenosis supravalvular, 35% en coartación aórtica y 14% en estenosis valvular aórtica. Conclusión: la intervención con balón es una medida paliativa que permite a los enfermos con obstrucciones izquierdas alcanzar la talla diana.

  15. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  16. Creation of transcatheter aortopulmonary and cavopulmonary shunts using magnetic catheters: feasibility study in swine.

    Science.gov (United States)

    Levi, Daniel S; Danon, Saar; Gordon, Brent; Virdone, Nicky; Vinuela, Fernando; Shah, Sanjay; Carman, Greg; Moore, John W

    2009-05-01

    Surgical shunts are the basic form of palliation for many types of congenital heart disease. The Glenn shunt (superior cavopulmonary connection) and central shunt (aortopulmonary connection) represent surgical interventions that could potentially be accomplished by transcatheter techniques. We sought to investigate the efficacy of using neodymium iron boron (NdFeB) magnetic catheters to create transcatheter cavopulmonary and aortopulmonary shunts. NdFeB magnets were machined and integrated into catheters. "Target" catheters were placed in the pulmonary arteries (PAs), and radiofrequency "perforation" catheters were placed in either the descending aorta (DAo) for central shunts or the superior vena cava (SVC) for Glenn shunts. The magnet technique or "balloon target" method was used to pass wires from the DAo or the SVC into the PA. Aortopulmonary and cavopulmonary connections were then created using Atrium iCAST covered stents. Magnet catheters were used to perforate the left pulmonary artery from the DAo, thereby establishing a transcatheter central shunt. Given the orientation of the vasculature, magnetic catheters could not be used for SVC-to-PA connections; however, perforation from the SVC to the right pulmonary artery was accomplished with a trans-septal needle and balloon target. Transcatheter Glenn or central shunts were successfully created in four swine.

  17. Titan Balloon Convection Model Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  18. Percutaneous transluminal angioplasty of infrarenal arteries in intermittent claudication

    DEFF Research Database (Denmark)

    Henriksen, L O; Jørgensen, B; Holstein, P E;

    1988-01-01

    Percutaneous transluminal angioplasty was performed on 55 iliac and 31 femoropopliteal arteries in 71 patients with intermittent claudication (23 women, 48 men). The two-year patency rate was 80% after iliac and 41% after femoropopliteal angioplasty. In 17 femoropopliteal cases with lesions greater...... than or equal to 5 cm the 2-year patency rate was only 32%, but the corresponding figure for shorter lesions was 53%. Complicating haematoma appeared in 10% of the cases and the arterial state deteriorated in one patient. There was no distal embolization. Percutaneous transluminal angioplasty...

  19. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  20. Clopidogrel Responsiveness in Patients Undergoing Peripheral Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pastromas, Georgios, E-mail: geopastromas@gmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios, E-mail: adiamantopoulos@gmail.com; Kitrou, Panagiotis, E-mail: panoskitrou@gmail.com; Karnabatidis, Dimitrios, E-mail: karnaby@med.upatras.gr; Siablis, Dimitrios, E-mail: siablis@med.upatras.gr [Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-12-15

    Purpose: To investigate the incidence and clinical significance of platelet responsiveness in patients receiving clopidogrel after peripheral angioplasty procedures. Materials and Methods: This prospective study included patients receiving antiplatelet therapy with clopidogrel 75 mg after infrainguinal angioplasty or stenting and who presented to our department during routine follow-up. Clopidogrel responsiveness was tested using the VerifyNow P2Y12 Assay. Patients with residual platelet reactivity units (PRU) {>=} 235 were considered as nonresponders (NR group NR), whereas patients with PRU < 235 were considered as normal (responders [group R]). Primary end points were incidence of resistance to clopidogrel and target limb reintervention (TLR)-free survival, whereas secondary end points included limb salvage rates and the identification of any independent predictors influencing clinical outcomes. Results: In total, 113 consecutive patients (mean age 69 {+-} 8 years) with 139 limbs were enrolled. After clopidogrel responsiveness analysis, 61 patients (53.9 %) with 73 limbs (52.5 %) were assigned to group R and 52 patients (46.1 %) with 66 limbs (47.5 %) to group NR. Mean follow-up interval was 27.7 {+-} 22.9 months (range 3-95). Diabetes mellitus, critical limb ischemia, and renal disease were associated with clopidogrel resistance (Fisher's exact test; p < 0.05). According to Kaplan-Meier analysis, TLR-free survival was significantly superior in group R compared with group NR (20.7 vs. 1.9 %, respectively, at 7-year follow-up; p = 0.001), whereas resistance to clopidogrel was identified as the only independent predictor of decreased TLR-free survival (hazard rate 0.536, 95 % confidence interval 0.31-0.90; p = 0.01). Cumulative TLR rate was significantly increased in group NR compared with group R (71.2 % [52 of 73] vs. 31.8 % [21 of 66], respectively; p < 0.001). Limb salvage was similar in both groups. Conclusion: Clopidogrel resistance was related with

  1. 内膜下血管成形术并发症的防治%The prevention and management of subintimal angioplasty complications

    Institute of Scientific and Technical Information of China (English)

    陆信武; 李维敏; 黄英; 陆民; 黄新天; 刘晓兵; 殷敏毅; 蒋米尔

    2009-01-01

    Objective The purpose of this study was to assess the prevention and management of subintimal angioplasty(SlA) to treat lower extremity arterial occlusions. Methods From December 2003 to May 2008, 106 lower extremities with arterial occlusions ( median length of 10. 8 cm, range from 4. 5 to 28. 0 cm) were treated on an intention-to-treat basis with SIA. Twenty-one lower extremities had disabling claudication and 85 had limb-threatening ischemia. Main outcome measures included the occurrences of SIA complications and their prevention and management. In order to prevent and cure perforation of a vessel and the important collaterals being compromised, the recanalisation of SIA was performed in the "roadmap" of DSA, the guide wire was advanced with top loop through the subintimal plane until the occlusion was passed, the position of the catheter which was confirmed by injection of a small amount of contrast media during the manipulations. In order to prevent and cure acute reocclusion and embolisation, subintimal angioplasty of long occlusion was performed by long suitable diameter balloon catheters, with prolonged (2 to 3 min) inflation, stents were only placed with residual stenoses and intimal flaps. Anticoagulation was administered for 3 to 5 d and then antiplatelet treatment was given for 6 months. Results The subcutaneous light gore of arterial access sites was seen in five legs, no arterial embolisation occurred. The perforation rate was 6% (7 legs), but no serious outcomes occurred. One patient had been amputated because of important collaterals being compromised. Three legs had acute occlusion in subintimal recanalisation and one patient converted what would have been an above-knee bypass, into a below-knee bypass. Conclusions The complications of subintimal angioplasty include perforation, embolisation, acute recanalisation occlusion and important collaterals being compromised. Most of these complications can be prevented and cured, few serious outcomes occur

  2. Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten

    Energy Technology Data Exchange (ETDEWEB)

    Landwehr, P.; Lackner, K. (Wuerzburg Univ. (Germany, F.R.). Inst. fuer Roentgendiagnostik); Goetz, R. (Wuerzburg Univ. (Germany, F.R.). Abt. fuer Nephrologie)

    1990-09-01

    On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

  3. Ruptured high flow gastric varices with an intratumoral arterioportal shunt treated with balloon-occluded retrograde transvenous obliteration during temporary balloon occlusion of a hepatic artery

    Institute of Scientific and Technical Information of China (English)

    Motoki Nakai; Morio Sato; Hirohiko Tanihata; Tetsuo Sonomura; Shinya Sahara; Nobuyuki Kawai; Masashi Kimura; Masaki Terada

    2006-01-01

    A patient presented with hematemesis due to gastric variceal bleeding with an intratumoral arterioportal shunt. Contrast-enhanced CT revealed gastric varices and hepatocellular carcinoma with tumor thrombi in the right portal vein. Angiography and angio-CT revealed a marked intratumoral arterioportal shunt accompanied with reflux into the main portal vein and gastric varices. Balloon-occluded retrograde venography from the gastro-renal shunt showed no visualization of gastric varices due to rapid blood flow through the intratumoral arterioportal shunt. The hepatic artery was temporarily occluded with a balloon catheter to reduce the blood flow through the arterioportal shunt, and then concurrent balloon-occluded retrograde transvenous obliteration (BRTO) was achieved. Vital signs stabilized immediately thereafter, and contrast-enhanced CT revealed thrombosed gastric varices. Worsening of hepatic function was not recognized. BRTO combined with temporary occlusion of the hepatic artery is a feasible interventional procedure for ruptured high flow gastric varices with an intratumoral arterioportal shunt.

  4. Buddy balloon for TAVI.

    Science.gov (United States)

    Balkin, Jonathan; Silberman, Shuli; Almagor, Yaron

    2013-11-15

    Percutaneous transfemoral aortic valve replacement is a new rapidly evolving technique that has made significant progress in recent years. The technology is however limitted and in some cases has resulted in failure to deliver the prosthetic valve. We describe a new technique using a buddy balloon, from the contralateral femoral artery, to assist in crossing the native aortic valve in those cases where extreme calcification and or tortuosity have caused the delivery system to hang up on the aortic wall. The technique is easily applied and facilitates the success of the procedure in cases which may otherwise have to be converted to open surgical aortic valve replacement.

  5. A Methane Balloon Inflation Chamber

    Science.gov (United States)

    Czerwinski, Curtis J.; Cordes, Tanya J.; Franek, Joe

    2005-01-01

    The various equipments, procedure and hazards in constructing the device for inflating a methane balloon using a standard methane outlet in a laboratory are described. This device is fast, safe, inexpensive, and easy to use as compared to a hydrogen gas cylinder for inflating balloons.

  6. Central venous catheter - dressing change

    Science.gov (United States)

    ... during cancer treatment Bone marrow transplant - discharge Central venous catheter - flushing Peripherally inserted central catheter - flushing Sterile technique Surgical wound care - open Review Date 9/17/2016 Updated by: ...

  7. Nationwide Eclipse Ballooning Project

    Science.gov (United States)

    Colman Des Jardins, Angela; Berk Knighton, W.; Larimer, Randal; Mayer-Gawlik, Shane; Fowler, Jennifer; Harmon, Christina; Koehler, Christopher; Guzik, Gregory; Flaten, James; Nolby, Caitlin; Granger, Douglas; Stewart, Michael

    2016-05-01

    The purpose of the Nationwide Eclipse Ballooning Project is to make the most of the 2017 rare eclipse event in four main areas: public engagement, workforce development, partnership development, and science. The Project is focused on two efforts, both student-led: online live video of the eclipse from the edge of space and the study of the atmospheric response to the eclipse. These efforts, however, involving more than 60 teams across the US, are challenging in many ways. Therefore, the Project is leveraging the NASA Space Grant and NOAA atmospheric science communities to make it a success. The first and primary topic of this poster is the NASA Space Grant supported online live video effort. College and high school students on 48 teams from 31 states will conduct high altitude balloon flights from 15-20 locations across the 8/21/2017 total eclipse path, sending live video and images from near space to a national website. Video and images of a total solar eclipse from near space are fascinating and rare. It’s never been done live and certainly not in a network of coverage across a continent. In addition to the live video to the web, these teams are engaged in several other science experiments as secondary payloads. We also briefly highlight the eclipse atmospheric science effort, where about a dozen teams will launch over one hundred radiosondes from across the 2017 path, recording an unprecedented atmospheric data sample. Collected data will include temperature, density, wind, humidity, and ozone measurements.

  8. Tunneled dialysis catheter exchange with fibrin sheath disruption is not associated with increased rate of bacteremia.

    Science.gov (United States)

    Valliant, Amanda M; Chaudhry, Muhammad K; Yevzlin, Alexander S; Astor, Brad; Chan, Micah R

    2015-01-01

    Tunneled dialysis catheters are the most common form of vascular access among incident dialysis patients in the United States. Fibrin sheath formation is a frequent cause of late catheter dysfunction requiring an exchange procedure with balloon disruption of the fibrin sheath. It is unknown whether fibrin sheath disruption is associated with increased incidence of bacteremia or catheter failure. We reviewed all tunneled dialysis catheter exchange procedures at the University of Wisconsin between January 2008 and December 2011. The primary outcome was incidence of bacteremia, defined as positive blood cultures within 2 weeks of the procedure. Catheter failure, requiring intervention or replacement, was examined as a secondary outcome. Baseline characteristics examined included diabetic status, gender, race and age. A total of 163 procedures were reviewed; 67 (41.1%) had fibrin sheath disruption and 96 did not. Bacteremia occurred in 4.5% (3/67) of those with and 3.1% (3/97) of those without fibrin sheath disruption (p=0.65). Fibrin sheath disruption was not significantly associated with the risk of catheter failure (adjusted hazard ratio [aHR]=1.34; 95% confidence interval [CI]: 0.87-2.10; p=0.18). Diabetes was associated with greater risk of catheter failure (aHR=1.88; 95% CI: 1.19-2.95; p=0.006), whereas higher age was associated with a lower risk of catheter failure (aHR per 10 years=0.83; 95% CI: 0.72-0.96; p=0.01). This study demonstrates that there is no significant increase in bacteremia and subsequent catheter dysfunction rates after fibrin sheath disruption compared to simple over the wire exchange. These results are encouraging given the large numbers of patients utilizing tunneled catheters for initial hemodialysis access and the known rates of fibrin sheath formation leading to catheter failure.

  9. Balloon dilatation biopsy of the biliary stricture through the percutaneous transhepatic biliary drainage tract: Feasibility and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Ji Hoon; Ryeom, Hun Kyu; Jang, Yun Jin; Kim, Gab Chul; Cho, Seung Hyun; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2016-01-15

    To evaluate the feasibility and diagnostic accuracy of the balloon dilatation biopsy for the biliary stricture through the percutaneous transhepatic biliary drainage (PTBD) tract. The study included 35 patients who underwent balloon dilatation biopsy for the biliary stricture through the PTBD tract. Balloon dilatation was done with a balloon catheter of 10-mm or 12-mm diameter. Soft tissue adherent to the retrieved balloon catheter and soft tissue components separated by gauze filtration of evacuated bile were sampled for histopathologic examination. The results were compared with the final diagnosis which was made by clinical and imaging follow-up for mean 989 days (n = 34) and surgery with histopathologic examination (n = 1). Procedure-related complications and diagnostic accuracy were assessed. Tissues suitable for histopathologic examination were obtained in 31 out of 35 patients (88.6%). In 3 patients, self-limiting hemobilia was noted. No major complication was noted. The sensitivity, specificity, diagnostic accuracy, positive and negative predictive values for diagnosis of malignant stricture were 70.0%, 100%, 90.3%, 100%, and 87.5%, respectively. Balloon dilatation biopsy of the biliary stricture through the PTBD tract is a feasible and accurate diagnostic method. It can be a safe alternative to the endoscopic retrograde cholangiography biopsy or forceps biopsy through the PTBD tract.

  10. Middle Ear Pressure Changes during Balloon Eustachian Tuboplasty.

    Science.gov (United States)

    Smith, Matthew E; Tysome, James R

    2017-01-01

    Objective Balloon eustachian tuboplasty (BET) has entered clinical use as a treatment for eustachian tube dysfunction. Some surgeons perform myringotomy prior to BET due to concerns that the increase in middle ear (ME) pressure caused by BET may cause otic barotrauma. We investigated the ME pressure changes occurring during BET in cadavers. Study design Human cadaver investigation of a surgical technique Setting Laboratory study at a tertiary referral center. Subjects and Methods ME pressures were recorded from fresh-frozen cadavers, and BET was performed with the Bielefeld balloon catheter inflated to 10 bar. Peak ME pressures were recorded during catheter insertion, inflation, deflation, and removal. A second pressure measurement was taken 15 seconds after each stage to assess the residual pressures. All BET procedures were repeated at least once. Where transmastoid recordings were made, BET was repeated, measuring pressure via a myringotomy to ensure equivalence. Results Data from 25 procedures in 13 ears (9 heads) were analyzed. A consistent pattern of ME pressure change was observed in all cases. Positive pressures occurred on insertion (maximum, 26 daPa) and inflation (maximum, 99 daPa) and negative pressures on deflation (maximum, -46 daPa) and removal (maximum, -42 daPa). There were no significant pressure differences between first and second procedures, except at 15 seconds after insertion ( P = .04). Conclusion In adult cadaveric specimens, BET induces ME pressures within the normal physiologic range. On this basis, routine myringotomy prior to BET in adults is not necessary.

  11. Stingray balloon used in slender percutaneous coronary intervention for chronic total occlusion.

    Science.gov (United States)

    Wu, Eugene B; Ikari, Yuji

    2013-07-01

    Slender chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using 5 Fr radial Ikari catheter is possible in simple CTO cases. We report a case where we initially thought the LAD CTO was short and easy, but we found that the CTO had a considerable amount of calcium and also some tortuosity, making simple wire crossing impossible. We used a Stingray balloon to perform re-entry by tracking the balloon over an Ultimate Bros 3 gram wire using an extension wire. We successfully punctured into true lumen and completed stenting through a slender 5 Fr system. This case demonstrates the beauty of combining the advances in CTO PCI from the East and the West together and also demonstrates the possibility of using the Stingray system in a 5 Fr guiding catheter.

  12. Lentivirus-mediated RNAi knockdown of the gap junction protein, Cx43, attenuates the development of vascular restenosis following balloon injury.

    Science.gov (United States)

    Han, Xiao-Jian; Chen, Min; Hong, Tao; Zhu, Ling-Yu; He, Dan; Feng, Jiu-Geng; Jiang, Li-Ping

    2015-04-01

    Percutaneous coronary intervention [PCI or percutaneous transluminal coronary angioplasty (PTCA)] has been developed into a mature interventional treatment for atherosclerotic cardiovascular disease. However, the long-term therapeutic effect is compromised by the high incidence of vascular restenosis following angioplasty, and the underlying mechanisms of vascular restenosis have not yet been fully elucidated. In the present study, we investigated the role of the gap junction (GJ) protein, connexin 43 (Cx43), in the development of vascular restenosis. To establish vascular restenosis, rat carotid arteries were subjected to balloon angioplasty injury. At 0, 7, 14 and 2 days following balloon injury, the arteries were removed, and the intimal/medial area of the vessels was measured to evaluate the degree of restenosis. We found that the intimal area gradually increased following balloon injury. Intimal hyperplasia and restenosis were particularly evident at 14 and 28 days after injury. In addition, the mRNA and protein expression of Cx43 was temporarily decreased at 7 days, and subsequently increased at 14 and 28 days following balloon injury, as shown by RT-PCR and western blot analysis. To determine the involvement of Cx43 in vascular restenosis, the lentivirus vector expressing shRNA targeting Cx43, Cx43-RNAi-LV, was used to silence Cx43 in the rat carotid arteries. The knockdown of Cx43 effectively attenuated the development of intimal hyperplasia and vascular restenosis following balloon injury. Thus, our data indicate the vital role of the GJ protein, Cx43, in the development of vascular restenosis, and provide new insight into the pathogenesis of vascular restenosis. Cx43 may prove to be a novel potential pharmacological target for the prevention of vascular restenosis following PCI.

  13. Emergency coronary artery bypass surgery for failed percutaneous coronary angioplasty. A 10-year experience.

    Science.gov (United States)

    Craver, J M; Weintraub, W S; Jones, E L; Guyton, R A; Hatcher, C R

    1992-01-01

    Six hundred ninety-nine patients have required emergency coronary artery bypass after failed elective percutaneous coronary angioplasty during the decade September 1980 through December 1990. This represents 4% of 9860 patients having 12,146 elective percutaneous coronary angioplasty procedures during this interval. Emergency coronary artery bypass was required for acute refractory myocardial ischemia in 82%. Hospital mortality rate for all patients was 3.1%; 3.7% in patients with refractory myocardial ischemia but 0.8% in patients without refractory myocardial ischemia, p = 0.08. Postprocedural Q-wave myocardial infarctions were observed in 21% versus 2.4%, p less than 0.0001, and intra-aortic balloon pumping was required in 19% with versus 0.8% without refractory myocardial ischemia, p less than 0.0001. Multivessel disease, p = 0.004, age older than 65 years, p = 0.005, and refractory myocardial ischemia, p = 0.08, interacted to produce the highest risk of in-hospital death. Follow-up shows that there have been 28 additional late deaths, including 23 of cardiac causes for a 91% survival at 5 years. Freedom from both late death and Q-wave myocardial infarction at 5 years was 61%. In the group going to emergency coronary artery bypass with refractory myocardial ischemia, the late cardiac survival was 90%, and in those without ischemia, 92% at 5 years, p = not significant. The MI--free survival in the group with refractory ischemia, however, was 56% versus 83% in the group without ischemia, p less than 0.0001. Multivariate analysis showed the highest late event rates for patients with Q-wave myocardial infarction at the initial emergency coronary artery bypass, age older than 65 years, angina class III or IV, and prior coronary bypass surgery. In spite of a continuing high incidence of early acute myocardial infarction and an increasing operative mortality rate (7%) in the latest 3 years cohort of patients, excellent late survival and low subsequent cardiac event

  14. Electrifying catheters with light

    NARCIS (Netherlands)

    M. Pekař (Martin); J. Van Rens (Jeannet); M.B. van der Mark (Martin)

    2017-01-01

    textabstractSmart minimally invasive devices face a connectivity challenge. An example is found in intracardiac echocardiography where the signal transmission and supply of power at the distal end require many thin and fragile wires in order to keep the catheter slim and flexible. We have built a

  15. Endoscopic minor papilla balloon dilation for the treatment of symptomatic pancreas divisum.

    Science.gov (United States)

    Yamamoto, Natsuyo; Isayama, Hiroyuki; Sasahira, Naoki; Tsujino, Takeshi; Nakai, Yousuke; Miyabayashi, Koji; Mizuno, Suguru; Kogure, Hirofumi; Sasaki, Takashi; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2014-08-01

    A subpopulation of patients with pancreas divisum experience symptomatic events such as recurrent acute pancreatitis and chronic pancreatitis. Minor papilla sphincterotomy has been reported as being an effective treatment. The aim of this study was to evaluate the safety and efficacy of endoscopic balloon dilation for the minor papilla. Between 2000 and 2012, 16 patients were retrospectively included in this study. After endoscopic balloon dilation for the minor papilla was received, a pancreatic stent or a nasal pancreatic drainage catheter was placed for 1 week. If a stricture or obstruction was evident, it was treated with balloon dilation followed by long-term stent placement (1 year). When an outflow of pancreatic juice was disturbed by a pancreatic stone, endoscopic stone extraction was performed. Balloon dilation and stent placement were achieved and were successful in all the cases (16/16; 100%). Clinical improvement was achieved in 7 (84.7%) of the 9 patients with recurrent acute pancreatitis and in 6 (85.7%) of the 7 patients with chronic pancreatitis. Early complications were observed in 1 (6.3%) patient. Pancreatitis or bleeding related to balloon dilation was not observed. Endoscopic balloon dilation for the minor papilla is feasible for the management of symptomatic pancreas divisum.

  16. Expanding TAVI options: elective rotational atherectomy during trans-catheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, Anna; Lunardi, Mattia; Ariotti, Sara; Ferrero, Valeria; Vassanelli, Corrado; Ribichini, Flavio, E-mail: flavio.ribichini@univr.it

    2015-01-15

    Summary: Aortic valve stenosis (AVS) in the elderly is frequently associated to coronary artery disease (CAD). In patients with significant coronary stenosis surgical valve replacement is associated to coronary bypass grafting, but whether coronary angioplasty is needed in patients receiving trans-catheter aortic valve implantation (TAVI) is unknown. Given the frequent complexity of CAD in the elderly with calcific AVS, rotational atherectomy (RA) may be needed in some cases. No data are available about feasibility and safety of RA during TAVI. The need for myocardial revascularization in TAVI candidates is discussed, and a series of RA cases performed during TAVI is described.

  17. Immediate Outcome of Balloon Mitral Valvuloplasty with JOMIVA Balloon during Pregnancy

    Science.gov (United States)

    Ramasamy, Ramona; Kaliappan, Tamilarasu; Gopalan, Rajendiran; Palanimuthu, Ramasmy; Anandhan, Premkrishna

    2017-01-01

    Introduction Rheumatic mitral stenosis is the most common Valvular Heart Disease encountered during pregnancy. Balloon Mitral Valvuloplasty (BMV) is one of the treatment option available if the symptoms are refractory to the medical management and the valve anatomy is suitable for balloon dilatation. BMV with Inoue balloon is the most common technique being followed worldwide. Over the wire BMV is a modified technique using Joseph Mitral Valvuloplasty (JOMIVA) balloon catheter which is being followed in certain centres. Aim To assess the immediate post procedure outcome of over the wire BMV with JOMIVA balloon. Materials and Methods Clinical and echocardiographic parameters of pregnant women with significant mitral stenosis who underwent elective BMV with JOMIVA balloon in our institute from 2005 to 2015 were analysed retrospectively. Severity of breathlessness (New York Heart Association Functional Class), and duration of pregnancy was included in the analysis. Pre procedural echocardiographic parameters which included severity of mitral stenosis and Wilkin’s scoring were analysed. Clinical, haemodynamic and echocardiographic outcomes immediately after the procedure were analysed. Results Among the patients who underwent BMV in our Institute 38 were pregnant women. Twenty four patients (63%) were in New York Heart Association (NYHA) Class III. All of them were in sinus rhythm except two (5%) who had atrial fibrillation. Thirty four patients (89.5%) were in second trimester of pregnancy at the time of presentation and four (10.5%) were in third trimester. Echocardiographic analysis of the mitral valve showed that the mean Wilkin’s score was 7.3. Mean mitral valve area pre procedure was 0.8 cm2. Mean gradient across the valve was 18 mmHg. Ten patients (26.5%) had mild mitral regurgitation and none had more than mild mitral regurgitation. Thirty six patients had pulmonary hypertension as assessed by tricuspid regurgitation jet velocity. All of them underwent BMV

  18. Percutaneous transluminal angioplasty in a patient with chronic cerebrospinal venous insufficiency and persistent left superior vena cava.

    Science.gov (United States)

    Lupattelli, T; Benassi, F; Righi, E; Bavera, P; Bellagamba, G

    2014-04-01

    Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome characterized by stenoses of the internal jugular veins (IJVs) and/or azygos veins and formation of collateral venous channels. A case of a 57-year-old patient with CCSVI in whom the venous outflow from the left IJV to the right atrium occurred through a venous anomaly, the persistent left superior vena cava (PLSVC), is reported. PLSVC is caused by persistence of the left anterior cardinal vein that drains blood from the limb effluent from the left and the left side of head and neck into coronary sinus (Type a), or in the left atrium (Type b). PLSVC can be associated either with innominate vein hypoplasia or other congenital heart abnormalities. Because of evidence of left innominate vein hypoplasia, angioplasty was not performed using the ordinary route but passing with the balloon directly through the PLSVC up to the left IJV. Finally, angioplasty was carried out in a standard manner in the right IJV as well as in the azygous vein. Confirmation angiogram revealed complete reopening of all treated vessels with no evidence of peri- and postoperative complications. The patient was discharged home the following day in good general conditions. PLSVC is a rare congenital vein anomaly but in case of concomitant innominate vein hypoplasia may prove to be a valuable alternative to treat patients with IJV diseases.

  19. Minimally invasive per-catheter occlusion and dilation procedures for congenital cardiovascular abnormalities in dogs.

    Science.gov (United States)

    Tobias, Anthony H; Stauthammer, Christopher D

    2010-07-01

    With ever-increasing sophistication of veterinary cardiology, minimally invasive per-catheter occlusion and dilation procedures for the treatment of various congenital cardiovascular abnormalities in dogs have become not only available, but mainstream. Much new information about minimally invasive per-catheter patent ductus arteriosus occlusion has been published and presented during the past few years. Consequently, patent ductus arteriosus occlusion is the primary focus of this article. Occlusion of other less common congenital cardiac defects is also briefly reviewed. Balloon dilation of pulmonic stenosis, as well as other congenital obstructive cardiovascular abnormalities is discussed in the latter part of the article.

  20. Aggressive plaque modification with rotational atherectomy and cutting balloon for optimal stent expansion in calcified lesions

    Science.gov (United States)

    Tang, Zhe; Bai, Jing; Su, Shao-Ping; Lee, Pui-Wai; Peng, Liang; Zhang, Tao; Sun, Ting; Nong, Jing-Guo; Li, Tian-De; Wang, Yu

    2016-01-01

    Objective To evaluate the factors affecting optimal stent expansion in calcified lesions treated by aggressive plaque modification with rotational atherectomy (RA) and a cutting balloon (CB). Methods From January 2014 to May 2015, 92 patients with moderate to severe coronary calcified lesions underwent rotational atherectomy and intravascular ultrasound imaging at Chinese PLA General Hospital (Beijing, China) were included in this study. They were divided into a rotational artherectomy combined with cutting balloon (RACB) group (46 patients treated with RA followed by CB angioplasty) and an RA group (46 patients treated with RA followed by plain balloon angioplasty). Another 40 patients with similar severity of their calcified lesions treated with plain old balloon angioplasty (POBA) were demographically matched to the other groups and defined as the POBA group. All patients received a drug-eluting stent after plaque preparation. Lumen diameter and lumen diameter stenosis (LDS) were measured by quantitative coronary angiography at baseline, after RA, after dilatation, and after stenting. Optimal stent expansion was defined as the final LDS < 10%. Results The initial and post-RA LDS values were similar among the three groups. However, after dilatation, the LDS significantly decreased in the RACB group (from 54.5% ± 8.9% to 36.1% ± 7.1%) but only moderately decreased (from 55.7% ± 7.8% to 46.9% ± 9.4%) in the RA group (time × group, P < 0.001). After stenting, there was a higher rate of optimal stent expansion in the RACB group (71.7% in the RACB group, 54.5% in the RA group, and 15% in the POBA group, P < 0.001), and the final LDS was significantly diminished in the RACB group compared to the other two groups (6.0% ± 2.3%, 10.8% ± 3.3%, 12.7% ± 2.1%, P < 0.001). Moreover, an LDS ≤ 40% after plaque preparation (OR = 2.994, 95% CI: 1.297–6.911) was associated with optimal stent expansion, which also had a positive correlation with the appearance of a

  1. Dosimetric fundamentals of endovascular brachytherapy using Re-188 to prevent restenosis after angioplasty; Dosimetrische Grundlagen fuer die endovaskulaere Therapie mit Re-188 zur Praevention der Restenose nach Angioplastie

    Energy Technology Data Exchange (ETDEWEB)

    Kotzerke, J.; Rentschler, M.; Glatting, G.; Schneider, E. [Ulm Univ. (Germany). Zentrum fuer Radiologie; Stabin, M. [Oak Ridge Inst. for Science and Education (ORISE), TN (United States); Knapp, F.F. Jr. [Oak Ridge National Lab., TN (United States). Nuclear Medicine Group; Reske, S.N.

    1998-03-01

    Various radionuclides can be used for endovascular brachytherapy. A new concept is to inflate the balloon of a dilitation catheter with a radioactive solution. Re-188 can be eluated from a generator system and is available daily. The aim of this study was to obtain dosimetric data for this radionuclide. The dose decrease of Re-188 was calculated and measured with a TLD-system radial to a balloon catheter typically used in cardiology (diameter: 3 mm, length: 20 mm). Using a specific acitivity of 370 MBq/ml a dose of 0,3 Gy could be achieved within 1 min in a TLD in contact with the balloon. Paired TLDs differed about 3%. A fast dose reduction of 50% and 10% were stated within 0.5 mm and 2.5 mm, respectively. Calculated and measured values were in good agreement. The data are comparable to those known for Y-90. Calculations of dose distribution are consistent with TLD measurements of Re-188. Using a specific activity of 1.85 GBq/ml, a dose of 10-15 Gy at the coronary artery wall can be achieved within 2-3 min. (orig./MG) [Deutsch] Fuer die endovaskulaere Brachytherapie stehen unterschiedliche Radionuklide zur Verfuegung. Ein interessantes Konzept ist die Nutzung eines fluessigen Betastrahlers in einem Ballonkatheter. Re-188 kann aus einem Generatorsystem gewonnen werden und steht somit taeglich zur Verfuegung. Es sollten dosimetrische Daten erhoben werden. Es wurde die radiale Abnahme der Dosis von Re-188 bei einem typischen Dilatationskatheter (Durchmesser 3 mm, Laenge 20 mm) berechnet und mit TLD-Messungen verglichen. Bei einer spezifischen Aktivitaet von 370 MBq/ml konnten 0,3 Gy pro 1 min in 0,5 mm Abstand von der Ballonwand gemessen werden. Doppelmessungen wiesen eine Abweichung von 3% auf. Ein schneller Dosisabfall von 50% innerhalb von 0,5 mm bzw. von 90% innerhalb von 2,5 mm wurde beobachtet. Messwerte und Berechnungen stimmten gut ueberein. Die Daten von Re-188 und Y-90 entsprechen sich weitgehend. Berechnungen ueber die Dosisverteilung von Re-188 stimmen

  2. Management of life-threatening celiac-hepatic arterial hemorrhage after pancreaticoduodenectomy: usefulness of temporary balloon occlusion

    Institute of Scientific and Technical Information of China (English)

    WANG Mao-qiang; GUO Li-ping; LIN Han-ying; DUAN Feng; LIU Feng-yong; WANG Zhi-jun

    2011-01-01

    When a large visceral artery is ruptured,uncontrolled bleeding may lead to hemodynamic collapse.Use of endovascular occlusion balloon catheter may provide rapid control of hemorrhage and facilitate definitive therapy.We reported two patients with massive hemorrhage from ruptured celiac-hepatic artery after pancreaticoduodenectomy,who were initially treated percutaneously by temporary selective balloon occlusion.They became critically hemodynamic unstable during the angiographic procedure.Through an 8Fr sheath,a 6Fr compliant latex occlusion balloon was placed proximal to the celiac trunk and inflated,and upon patient stabilization surgical revision and stent-graft placement were successfully performed in the two patients,respectively.Temporary selective balloon occlusion provides fast and effective bleeding control for patient with critically uncontrollable visceral arterial hemorrhage,permitting subsequent use of conventional techniques for management of the arterial bleeding source.

  3. Anaesthetic management for balloon dilation of cor triatriatum dexter in a dog.

    Science.gov (United States)

    De Monte, Valentina; Staffieri, Francesco; Caivano, Domenico; Bufalari, Antonello

    2015-06-10

    A three-month-old female Rottweiler puppy was referred for intravascular correction of a previously identified cor triatriatum dexter. Echocardiography confirmed the presence of a hyperechoic membrane that divided the right atrium into a cranial and caudal chamber. A foramen in this membrane allowed the blood to flow from the caudal to the cranial chamber. Balloon dilation of the defect under transthoracic echocardiographic guidance was scheduled for the following day. The dog was premedicated with 0.5 μg/kg sufentanil and 0.2 mg/kg midazolam administered intravenously. General anaesthesia was induced with 2 mg/kg propofol and maintained with inhaled isoflurane in oxygen; at the same time, a constant rate infusion of 0.5 μg/kg/h sufentanil was administered by means of an infusion pump. Uneventful ventricular and supraventricular tachyarrhythmias developed during the placement of catheters and balloon dilation. At the end of procedure, when the guide wire and balloon catheter were removed, normal sinus rhythm was observed. To the authors' knowledge, no previous reports have described the anaesthetic management of a balloon dilation procedure for cor triatriatum dexter in dogs.

  4. Percutaneous gastrostomy performed by radiologists using balloon replacement tubes. A simple interventional technique for the placement of nutritional catheters without endoscopy or surgery; Perkutane Gastrostomie mit Ballon-PEG-Ersatzsonden durch den Radiologen. Eine interventionelle Technik zur einfachen Einlage von Ernaehrungskathetern ohne chirurgischen oder endoskopischen Eingriff

    Energy Technology Data Exchange (ETDEWEB)

    Dinkel, H.P.; Triller, J. [Bern Univ. (Switzerland). Inst. fuer Diagnostische Radiologie

    2001-06-01

    Patients afflicted with stenotic head and neck or esophageal tumors often require artificial enteral feeding. Frequently passage of an endoscope through the esophagus is impossible in these patients. Interventional, fluoroscopically assisted, percutaneous gastrostomy (PG) by balloon replacement tubes is a feasible and successful alternative to percutaneous endoscopic gastrostomy (PEG) and the method of choice in patients where the esophagus cannot be passed with an endoscope anymore. Technical success rate is very high and serious complications are rare. Radiological PG is a feasible, equivalent alternative to PEG also in all other patients. We recommend PG with balloon gastrostomy tubes in conjunction with gastropexy performed with three to four T-fasteners, which are left in place for seven days in order to prevent dislocation and leakage. (orig.) [German] Patienten mit HNO-Tumoren oder malignen Oesophagusstenosen muessen oft mit einem gastroenteralen Stoma versorgt werden. Haeufig sind die Tumoren so stenosierend, dass eine perkutane endoskopische Gastrostomie (PEG) nicht mehr moeglich ist und eine chirurgische Gastrostomie durchgefuehrt wird. Wir berichten ueber die radiologisch-perkutane Gastrostomie (PG). Die perkutane Gastrostomie ist Methode der Wahl bei stark stenosierenden oesophagealen Prozessen. Auch bei anderen Patienten (ohne Passagehindernis) stellt die PG eine gleichwertige Alternative zur PEG dar. Die Erfolgsrate der PG liegt nahe 100%, Komplikationen sind selten. Wir empfehlen Ballon-arretierte Sonden (sog. Ballonersatzsonden) in Verbindung mit der perkutanen Gastropexie mit 3-4 Fadenzugankern, die fuer etwa 7 Tage belassen werden. (orig.)

  5. US Monthly Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Monthly winds aloft summary forms summarizing Pilot Balloon observational data for the United States. Generally labeled as Form 1114, and then transitioning to Form...

  6. US Daily Pilot Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Pilot Balloon observational forms for the United States. Taken by Weather Bureau and U.S. Army observers. Period of record 1918-1960. Records scanned from the NCDC...

  7. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  8. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  9. Angioplasty and stent treatment of transplant renal artery stenosis.

    Science.gov (United States)

    Del Pozo, Maitane; Martí, Jordi; Guirado, Lluís; Facundo, Carme; Canal, Cristina; de la Torre, Pablo; Ballarín, José; Díaz, Joan M

    2012-07-17

    Transplant renal artery stenosis is a major complication that requires a therapeutic approach involving surgery or angioplasty. The aim of this study was to analyse the evolution of renal transplant patients with renal allograft artery stenosis treated by angioplasty and stent placement. Thirteen patients were diagnosed with transplant renal artery stenosis. Clinical suspicion was based on deterioration of renal function and/or poorly controlled hypertension with compatible Doppler ultrasound findings. The diagnosis was confirmed by arteriography, performing an angioplasty with stent placement during the same operation. A progressive improvement in renal function was observed during the first 3 months after the angioplasty, and renal function then remained stable over 2 years. In addition, blood pressure improved during the first 2 years, and as a consequence there was no need to increase the average number of anti-hypertensive drugs administered (2.5 drugs per patient). In conclusion, angioplasty with stent placement is a safe and effective procedure for the treatment of transplant renal artery stenosis.

  10. Electrifying catheters with light.

    Science.gov (United States)

    Pekař, Martin; van Rens, Jeannet; van der Mark, Martin B

    2017-04-17

    Smart minimally invasive devices face a connectivity challenge. An example is found in intracardiac echocardiography where the signal transmission and supply of power at the distal end require many thin and fragile wires in order to keep the catheter slim and flexible. We have built a fully functional bench-top prototype to demonstrate that electrical wires may be replaced by optical fibers. The prototype is immediately scalable to catheter dimensions. The absence of conductors will provide intrinsic galvanic isolation as well as radio frequency (RF) and magnetic resonance imaging (MRI) compatibility. Using optical fibers, we show signal transfer of synthetic aperture ultrasound images as well as photo-voltaic conversion to supply all electronics. The simple design utilizes only off the shelf components and holds a promise of cost effectiveness which may be pivotal for translation of these advanced devices into the clinic.

  11. Simple balloon dilation for drug-eluting in-stent restenosis: An optical coherent tomography analysis

    Energy Technology Data Exchange (ETDEWEB)

    Arikawa, Ryo [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Yamaguchi, Hiroshi, E-mail: hyamaguchi@tsm.bbiq.jp [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Takaoka, Junichiro; Miyamura, Akihiro; Atsuchi, Nobuhiko; Ninomiya, Toshiko; Atsuchi, Yoshihiko [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Ohishi, Mitsuru [Department of Cardiovascular Medicine and Hypertension, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima (Japan); Terashima, Mitsuyasu [Department of Cardiology, Toyohashi Heart Center, Toyohashi (Japan); Kaneda, Hideaki [Okinaka Memorial Institute for Medical Research, Tokyo (Japan)

    2015-01-15

    Background: Although drug-eluting stent (DES) has significantly reduced restenosis, the treatment of DES-in-stent restenosis (ISR) remains a challenge with high restenosis rate. Methods: We examined whether morphologic appearance of restenosis tissue by optical coherent tomography (OCT) had an impact on outcomes after balloon angioplasty for DES-ISR. The morphologic appearance of restenosis tissue was qualitatively assessed for tissue structures such as homogeneous, layered, and heterogeneous patterns. Results: Using OCT, 50 patients with DES-ISR were divided into 2 groups: 25 lesions with homogeneous or layered patterns (homo/layered group) and 25 lesions with heterogeneous patterns (hetero group). Acute gain was larger in the hetero group (1.33 ± 0.41 mm vs. 1.06 ± 0.32 mm in the homo/layered group, P = 0.03). On intravascular ultrasound analysis, post-procedural percent neointimal area was smaller in the hetero group (27.4 ± 9.2% vs. 34.0 ± 11.2% in the homo/layered group, P = 0.05). Angiographic follow-up was performed in 37 lesions (74%). Follow-up minimal lumen diameter was larger in the hetero group (1.75 ± 0.89 mm vs. 1.01 ± 0.81 mm in the homo/layered group, P = 0.04). Target lesion revascularization rates tended to be lower in the hetero group (20% vs. 43% in the homo/layered group, P = 0.12). Conclusions: Balloon angioplasty was more effective for DES-ISR with heterogeneous tissue appearance than DES-ISR with homogeneous/layered tissue appearance. OCT assessment of DES-ISR morphology may be a useful adjunct in determining clinical strategies. Simple balloon dilatation is a possible treatment strategy for DES-ISR lesions with a heterogeneous appearance on OCT images.

  12. [Rotational stability of angiography catheters].

    Science.gov (United States)

    Schröder, J; Weber, M

    1992-10-01

    Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.

  13. Percutaneous transhepatic balloon dilation of biliary-enteric anastomotic strictures after surgical repair of iatrogenic bile duct injuries.

    Directory of Open Access Journals (Sweden)

    Andrew Y Lee

    Full Text Available PURPOSE: To evaluate the efficacy of percutaneous balloon dilation of biliary-enteric anastomotic strictures resulting from surgical repair of laparoscopic cholecystectomy-related bile duct injuries. MATERIAL AND METHODS: A total of 61 patients were referred to our institution from 1995 to 2010 for treatment of obstruction at the biliary-enteric anastomosis following surgical repair of laparoscopic cholecystectomy-related bile duct injuries. Of these 61 patients, 27 underwent surgical revision upon stricture diagnosis, and 34 patients were managed using balloon dilation. Of these 34 patients, 2 were lost to follow up, leaving 32 patients for analysis. The primary study objective was to determine the clinical success rate of balloon dilation of biliary-enteric anastomotic strictures. Secondary study objectives included determining anastomosis patency, rates of stricture recurrence following treatment, and morbidity. RESULTS: Balloon dilation of biliary-enteric anastomotic strictures was clinically successful in 21 of 32 patients (66%. Anastomotic stricture recurred in one of 21 patients (5% after an average of 13.1 years of follow-up. Patients who were unsuccessfully managed with balloon dilation required significantly more invasive procedures (6.8 v. 3.4; p = 0.02 and were left with an indwelling biliary catheter for a significantly longer period of time (8.8 v. 2.0 months; p = 0.02 than patients whose strictures could be resolved by balloon dilation. No significant differences in the number of balloon dilations performed (p = 0.17 or in the maximum balloon diameter used (p = 0.99 were demonstrated for patients with successful or unsuccessful balloon dilation outcomes. CONCLUSION: Percutaneous balloon dilation of anastomotic biliary strictures following surgical repair of laparoscopic cholecystectomy-related injuries may result in lasting patency of the biliary-enteric anastomosis.

  14. [Percutaneous renal angioplasty. Experience of the Radiodiagnostic Service of the Hotel-Dieu of France].

    Science.gov (United States)

    Atallah, N; Smayra, T; Slaba, S; Menassa, L

    1998-01-01

    We report on a series of 42 renal artery stenosis treated with percutaneous transluminal angioplasty (PTA). From January 1988 to June 1996, these 42 renal artery stenoses were found in 33 patients (17 males and 16 females) who had a balloon dilation (with 3 stent deployment); 9 of these lesions were bilateral and 7 on a single kidney. Initially, 32 patients had a high blood pressure and 6 a progressive renal failure. Twenty-two patients presented an atheromatous pathology, 7 a fibromuscular dysplasia. One patient had a Takayasu arteritis, and 3 others a stenosis of the renal graft artery. We find a complete initial success in 86% of the patients, a partial success in 14% without any catheterization failure. Global success rate of PTA is 90% at 29 months mean follow-up. A benefit of PTA regarding blood pressure was found in 84.4% of the patients. The renal function became normal in half the patients with renal insufficiency. PTA is an efficient treatment for renal artery stenosis. A satisfactory improvement of blood pressure and renal function is found in a high number of patients.

  15. Novel short-duration heating balloon dilatation with uniform temperature distribution: the heating conditions to suppress neo-intimal hyperplasia.

    Science.gov (United States)

    Kunio, M; Shimazaki, N; Arai, T; Sakurada, M

    2011-01-01

    We investigate the relation between the influences on smooth muscle cells and the chronic performances of our novel short-duration heating balloon dilatation to reveal the heating conditions which can suppress the neo-intimal hyperplasia after our heating dilatations. The temperature of prototype balloon catheter surface was measured during short-duration heating balloon dilatation ex vivo. There existed 2 °C temperature variations in the long direction of prototype balloon catheter at a maximum. The neo-intimal hyperplasia occupancy rate after our short-duration heating dilatations were measured in vivo porcine study. The neo-intimal hyperplasia was suppressed most at 75 °C in balloon peak temperature in vivo. The estimated dead rate of smooth muscle cells at this condition was about 13% by the Arrhenius equation. We think that the suppression of neo-intimal hyperplasia was obtained after our short-duration heating dilatation due to the proper decrease of smooth muscle cells by heating and no thermal damages to the adventitia and surrounding tissues.

  16. Limb-salvage angioplasty in poor surgical chronic liver disease and diabetic patients.

    Science.gov (United States)

    Hamdy, Hussam; El-Kolly, M; Ezzat, H; Abbas, M; Farouk, Y; Naser, M; Magdy, M; Elraouf, A

    2013-08-01

    Critical limb ischemia (CLI) in high surgical risk patients with chronic liver diseases has a grave prognosis with a one-year mortality rate of 20% and a one-year amputation rate of 25% after the initial diagnosis. According to Trans-Atlantic Inter-Society Consensus (TASC)-II Guidelines, revascularization (surgical & endovascular) is the treatment of choice for patients with critical limb ischemia (CLI). The primary goal of revascularization is to relieve ischemic rest pain, heal ulcers, prevent amputation, improve patient's quality of life (limb salvage) and secondary goal was the periprocedural complications. Endovascular techniques include balloon angioplasty, stents, stent-grafts, and plaque debulking procedures. Surgical options, identification of patients at risk of postoperative complications could have an impact on the indications for a procedure as well as permitting modifications of treatment to reduce the surgical risk This study evaluated the treatment out comas after limb salvage angioplasty for patients who otherwise would be candidates for primary amputation due to poor co-morbid conditions as chronic liver disease and diabetes. The clinical evaluation, laboratory investigations and abdominal ultrasonography were performed to all patients to evaluate their liver status. Patients were classified according to Child-pugh classification into child A, B & C. All patients were subjected to either detailed arterial duplex or C.T. angiography to assess their arterial lesions from January 2008- January 2010. 95 patients with critical limb ischemia (Rutherford categories 4, 5, 6) were treated by primary percutaneous transluminal angioplasty (PTA). No patient was excluded on the basis of the extent of arterial occlusive disease. The primary end points were immediate technical success, clinical improvement and limb salvages rates. Secondary end points were periprocedural complications and mortality. Most of the patients were male (54.7%) with mean age 62 (48

  17. Excimer laser assisted angioplasty in hemodialysis access intervention.

    Science.gov (United States)

    Yevzlin, Alexander S; Urbanes, Aris

    2009-01-01

    A case is described in which an excimer laser is used to assist angioplasty of a severe central venous lesion that is refractory to conventional techniques. Modern laser technology uses the ultraviolet (UV) spectral region to generate nanosecond pulses of energy. This results in photoablation, which is the process by which energy photons cause molecular bond disruption, while minimizing thermal damage to the surrounding vascular tissues. Further investigation of excimer laser assisted angioplasty in the setting of hemodialysis access intervention is needed to rigorously define its potential role. In occlusive disease where no conventional alternative is available, however, laser therapy is a viable option.

  18. Drug-Coated Balloon Venoplasty for In-Stent Restenosis in a Patient With Recurrent Pulmonary Vein Stenosis Post Ablation for Atrial Fibrillation: Initial Experience With a New Treatment Technique.

    Science.gov (United States)

    Rosenberg, Jonathan; Fisher, Westby G; Guerrero, Mayra; Smart, Steve; Levisay, Justin; Feldman, Ted; Salinger, Michael

    2016-05-01

    Pulmonary vein stenosis (PVS) is an uncommon but serious complication following radiofrequency ablation for atrial fibrillation. Occurrence of this complication has risen with increased rates of ablation procedures, with >50,000 AF ablation procedures performed per year, and can occur within weeks to months post procedure. Currently, the main therapies for PVS include percutaneous interventions with balloon angioplasty and stenting, but these treatments are complicated by a high rate of restenosis. The optimal treatment for recurrent pulmonary vein in-stent restenosis has not been determined. We describe the novel use of a paclitaxel drug-coated balloon for the treatment of in-stent restenosis of the pulmonary veins.

  19. Development of novel short-term heating angioplasty: diameter and elasticity change of vascular wall ex vivo

    Science.gov (United States)

    Shimazaki, Natsumi; Kaneko, Kenji; Nakatani, Eriko; Arai, Tsunenori

    2007-02-01

    In order to investigate the optimum operation parameters on novel short-term heating (angioplasty in which we demonstrated sufficient vascular dilatation with lower pressure by heat- induced denaturation of arterial collagen. And we have also demonstrated the suppression of intimal hyperplasia in animal experiments. We need to understand the PTDB dilatation mechanism to determine the optimum operation parameters. The prototype PTDB with diameter of 3mm was used in our experiments. The internal diameters of extracted fresh porcine carotid arteries at pre- and post- PTDB dilatation were measured. Balloon parameters were follows; pressure P=2atm, peak temperature in balloon T=60-80 °C, and heating duration t=4-30s. Morphological change in the media of dilated artery with PTDB were microscopically examined with Weigert staining. Elastic properties were carried out by stress-strain measurements with calculation of young's modulus. We found that PTDB dilatation provided the effect to prevent elastic recoil. We explained that the reason of this effect might be arrangement of micro- structure in the media, i.e., heat-denatured collagen fibers sustained the elastic recoil due to rubbery elastin fibers. The arterial elasticity was not significant different after PTDB dilatation. It was suggested that there could be no compliance mismatch after PTDB dilatation in physiological range. We found that a part of PTDB dilatation mechanism, in which the vascular wall structure played an important role. The optimum operation parameters for PTDB might be determined in consideration of collagen denaturation progress and arterial composition.

  20. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  1. 建立椎动脉急性血栓栓塞犬模型:微球囊导管临时隔截取栓%Establishment of acute vertebral artery thrombosis models in dogs:micro-balloon catheter temporary isolation for embolectomy

    Institute of Scientific and Technical Information of China (English)

    韦文姜; 肖承江; 李立恒; 江桂华

    2015-01-01

    BACKGROUND:In order to avoid distal arterial embolism fol owing mechanical thrombectomy, micro-bal oon catheter temporary isolation is applied to prevent thrombus shedding. OBJECTIVE:To investigate the safety and feasibility of adopting the micro-bal oon catheter technique in treatment of the hyperacute cerebral infarction. The micro-bal oon catheter technique can temporarily block the artery blood flow and isolate the embolism location fol owing mechanical thrombectomy and aspiration combined with thrombolysis. METHODS:Ten beagle dogs were included in this study. Under general anesthesia, the micro-bal oon catheter was delivered to the dominant vertebral artery through the femoral artery in al the dogs and it was fil ed and temporarily blocked the blood flow. Then the autologous thrombus was injected through the micro-catheter into proximal vertebral artery to make a thrombosis model. Al the dogs were equal y divided into two groups according to the embolectomy method:control group (receiving pure stent embolectomy, n=5) and experimental group (n=5). The experiment group was disrupted and aspirated thrombus combined with the drug thrombolysis after temporarily blocking out the blood flow and isolating the target artery by micro-bal oon catheter technique. After treatment, two groups underwent digital subtraction angiography to review the vertebral artery recanalization after different embolectomy methods. The hemodynamic status was evaluated through the thrombolysis in cerebral ischemia grade. Al the dogs were scanned with magnetic resonance diffusion weighted imaging before modeling and at 12 hours after the thrombectomy. The animals were kil ed to perform pathological examination after magnetic resonance diffusion weighted imaging (12 hours after the thrombectomy). The vessel recanalization rates and complications were calculated in the two groups. RESULTS AND CONCLUSION:The thromboembolism model was successful y established in the dominant vertebral artery of

  2. Assessment of risk of carotid occlusion with balloon Matas testing and dynamic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Tomoaki; Okuno, Takashi; Moriwaki, Hiroshi; Nakai, Ekini; Nishiguchi, Takashi; Hayashi, Seiji; Komai, Norihiko.

    1988-02-01

    Temporary occlusion of the internal carotid artery with a balloon catheter (balloon Matas test) and simultaneous dynamic computed tomographic scanning (DCT) were performed in four patients with intracranial aneurysms to determine their tolerance for permanent carotid occlusion. Five DCT parameters were evaluated: appearance time, peak time, peak height fitting, first effective moment, and transit time. The patients were characterized into three types: type I (2 patients) - lack of neurological deficit during the balloon Matas test and equally preserved cerebral blood flow (CBF) in the two hemispheres on DCT during carotid occlusion, type II (one patient) - a decreased CBF on the occluded side on DCT despite the lack of neurological deficit; type III (one patient) - neurological signs, such as disturbance of consciousness, aphasia, and right hemiparesis occuring immediately after the start of the balloon Matas test, and a decreased CBF in the region of the middle and anterior cerebral arteries on the occluded side. In the type III patient, occlusion of the internal carotid artery is contraindicated unless an EC-IC bypass procedure that can rapidly provide a large supply of blood is performed. It can be concluded that the balloon Matas/DCT method offers a reliable means of predicting the risk of carotid ligation. (Namekawa, K.).

  3. Balloon Dilatation of Pediatric Subglottic Laryngeal Stenosis during the Artificial Apneic Pause: Experience in 5 Children

    Directory of Open Access Journals (Sweden)

    J. Lisý

    2014-01-01

    Full Text Available Introduction. Balloon dilatation is a method of choice for treatment of laryngeal stenosis in children. The aim of procedure in apneic pause is to avoid new insertion of tracheostomy cannula. Patients and Methods. The authors performed balloon dilatation of subglottic laryngeal strictures (SGS in 5 children (3 girls and 2 boys without tracheotomy. Two of them with traumatic and inflammatory SGS had a tracheal cannula removed in the past. The other 3 children with postintubation SGS had never had a tracheostomy before. The need for tracheostomy due to worsening stridor was imminent for all of them. Results. The total of seven laryngeal dilatations by balloon esophagoplasty catheter in apneic pause was performed in the 5 children. The procedure averted the need for tracheostomy placement in 4 of them (80%. Failure of dilatation in girl with traumatic stenosis and concomitant severe obstructive lung disease led to repeated tracheostomy. Conclusion. Balloon dilatation of laryngeal stricture could be done in the absence of tracheostomy in apneic pause. Dilatation averted threatening tracheostomy in all except one case. Early complication after the procedure seems to be a negative prognostic factor for the outcome of balloon dilatation.

  4. Balloon Exoplanet Nulling Interferometer (BENI)

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Woodruff, Robert A.; Vasudevan, Gopal; Ford, Holland; Petro, Larry; Herman, Jay; Rinehart, Stephen; Carpenter, Kenneth; Marzouk, Joe

    2009-01-01

    We evaluate the feasibility of using a balloon-borne nulling interferometer to detect and characterize exosolar planets and debris disks. The existing instrument consists of a 3-telescope Fizeau imaging interferometer with 3 fast steering mirrors and 3 delay lines operating at 800 Hz for closed-loop control of wavefront errors and fine pointing. A compact visible nulling interferometer is under development which when coupled to the imaging interferometer would in-principle allow deep suppression of starlight. We have conducted atmospheric simulations of the environment above 100,000 feet and believe balloons are a feasible path forward towards detection and characterization of a limited set of exoplanets and their debris disks. Herein we will discuss the BENI instrument, the balloon environment and the feasibility of such as mission.

  5. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  6. Yellow Balloon in a Briar Patch.

    Science.gov (United States)

    Cooper, Frank; Fitzmaurice, Robert W.

    1978-01-01

    As part of a meteorology unit, sixth grade science students launched helium balloons with attached return postcards. This article describes Weather Service monitoring of the balloons and postcard return results. (MA)

  7. Cardiac tissue ablation with catheter-based microwave heating.

    Science.gov (United States)

    Rappaport, C

    2004-11-01

    The common condition of atrial fibrillation is often treated by cutting diseased cardiac tissue to disrupt abnormal electrical conduction pathways. Heating abnormal tissue with electromagnetic power provides a minimally invasive surgical alternative to treat these cardiac arrhythmias. Radio frequency ablation has become the method of choice of many physicians. Recently, microwave power has also been shown to have great therapeutic benefit in medical treatment requiring precise heating of biological tissue. Since microwave power tends to be deposited throughout the volume of biological media, microwave heating offers advantages over other heating modalities that tend to heat primarily the contacting surface. It is also possible to heat a deeper volume of tissue with more precise control using microwaves than with purely thermal conduction or RF electrode heating. Microwave Cardiac Ablation (MCA) is used to treat heart tissue that allows abnormal electrical conduction by heating it to the point of inactivation. Microwave antennas that fit within catheter systems can be positioned close to diseased tissue. Specialized antenna designs that unfurl from the catheter within the heart can then radiate specifically shaped fields, which overcome problems such as excessive surface heating at the contact point. The state of the art in MCA is reviewed in this paper and a novel catheter-based unfurling wide aperture antenna is described. This antenna consists of the centre conductor of a coaxial line, shaped into a spiral and insulated from blood and tissue by a non-conductive fluid filled balloon. Initially stretched straight inside a catheter for transluminal guiding, once in place at the cardiac target, the coiled spiral antenna is advanced into the inflated balloon. Power is applied in the range of 50-150 W at the reserved industrial, scientific and medical (ISM) frequency of 915 MHz for 30-90 s to create an irreversible lesion. The antenna is then retracted back into the

  8. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  9. Early rethrombosis in femoropopliteal occlusions treated with percutaneous transluminal angioplasty

    DEFF Research Database (Denmark)

    Jørgensen, B; Meisner, S; Holstein, P;

    1990-01-01

    One hundred and thirty-seven consecutive percutaneous transluminal angioplasties (PTA) were performed for femoropopliteal vascular disease including 58 stenoses and 79 total occlusions. Nine occlusions could not be crossed with the guidewire, but in the remaining 128 the haemodynamic and clinical...

  10. Subintimal angioplasty: predictors of long-term success.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2009-08-01

    To determine the clinical outcomes and success rates after percutaneous subintimal angioplasty (SIA) in patients with lower-limb occlusive lesions causing intermittent claudication (IC) or critical limb ischemia (CLI) at midterm to long-term follow-up. The secondary aim was to elicit factors predictive of a successful outcome.

  11. A meta-analytic overview of thrombectomy during primary angioplasty

    NARCIS (Netherlands)

    Luca, G. De; Navarese, E.P.; Suryapranata, H.

    2013-01-01

    INTRODUCTION: Even though primary angioplasty restores TIMI 3 flow in more than 90% of STEMI patients, the results in terms of myocardial perfusion are still unsatisfactory in a relatively large proportion of patients. Great interest has been focused in the last years on distal embolization as major

  12. Ballonnen in zee = balloons as marine litter

    NARCIS (Netherlands)

    Franeker, van J.A.

    2008-01-01

    Releasing balloons seems harmless. However, remains of balloons, especially valves and ribbons are becoming a common and persistent type of marine litter found on beaches. Following Dutch Queens day 2007, large numbers of Dutch balloons were found in Normandy, France. Animals may become entangled in

  13. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  14. Ballonnen in zee = balloons as marine litter

    NARCIS (Netherlands)

    Franeker, van J.A.

    2008-01-01

    Releasing balloons seems harmless. However, remains of balloons, especially valves and ribbons are becoming a common and persistent type of marine litter found on beaches. Following Dutch Queens day 2007, large numbers of Dutch balloons were found in Normandy, France. Animals may become entangled in

  15. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu [Northwestern Memorial Hospital, Department of Radiology (United States); Konanur, Meghana [Northwestern University Feinberg School of Medicine (United States); Foltz, Gretchen [Mallinckrodt Institute of Radiology at Washington University, Interventional Radiology (United States); Malaisrie, S. Chris [Northwestern Memorial Hospital, Department of Cardiothoracic Surgery (United States); Resnick, Scott, E-mail: sresnick@northwestern.edu [Northwestern University Feinberg School of Medicine, Department of Radiology, Interventional Radiology, Northwestern Memorial Hospital (United States)

    2016-03-15

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared and externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.

  16. Meteorological Support in Scientific Ballooning

    Science.gov (United States)

    Schwantes, Chris; Mullenax, Robert

    2017-01-01

    The weather affects every portion of a scientific balloon mission, from payload integration to launch, float, and impact and recovery. Forecasting for these missions is very specialized and unique in many aspects. CSBF Meteorology incorporates data from NWSNCEP, as well as several international meteorological organizations, and NCAR. This presentation will detail the tools used and specifics on how CSBF Meteorology produces its forecasts.

  17. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  18. The Accordion Sign in the Transplant Ureter: Ramifications During Balloon Dilation of Strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kriegshauser, J. Scott, E-mail: skriegshauser@mayo.edu; Naidu, Sailen G. [Mayo Clinic Hospital, Department of Radiology (United States); Chang, Yu-Hui H. [Mayo Clinic, Department of Biostatistics (United States); Huettl, Eric A. [Mayo Clinic Hospital, Department of Radiology (United States)

    2015-04-15

    PurposeThis study was designed to demonstrate the accordion sign within the transplant ureter and evaluate its ramifications during balloon dilation of strictures.MethodsA retrospective electronic chart and imaging review included demographic characteristics, procedure reports, and complications of 28 renal transplant patients having ureteral strictures treated with percutaneous balloon dilation reported in our transplant nephrology database during an 8-year period. The accordion sign was deemed present or absent on the basis of an imaging review and was defined as present when a tortuous ureter became kinked and irregular when foreshortened after placement of a wire or a catheter. Procedure-related urine leaks were categorized as occurring at the stricture if within 2 cm; otherwise, they were considered away from the stricture.ResultsThe accordion sign was associated with a significantly greater occurrence of leaks away from the stricture (P = 0.001) but not at the stricture (P = 0.34).ConclusionsThe accordion sign is an important consideration when performing balloon dilation procedures on transplant ureteral strictures, given the increased risk of leak away from the stricture. Its presence should prompt additional care during wire and catheter manipulations.

  19. Prophylactic Hypogastric Artery Ballooning in a Patient with Complete Placenta Previa and Increta

    Science.gov (United States)

    Yi, Kyong Wook; Seo, Tae-Seok; So, Kyeong A; Paek, Yu Chin; Kim, Hai-Joong

    2010-01-01

    Abnormal attachment of the placenta (Placenta accreta, increta, and percreta) is an uncommon but potentially lethal cause of maternal mortality from massive postpartum hemorrhage. A 33-yr-old woman, who had been diagnosed with a placenta previa, was referred at 30 weeks gestation. On ultrasound, a complete type of placenta previa and multiple intraplacental lacunae, suggestive of placenta accreta, were noted. For further evaluation of the placenta, pelvis MRI was performed and revealed findings suspicious of a placenta increta. An elective cesarean delivery and subsequent hysterectomy were planned for the patient at 38 weeks gestation. On the day of delivery, endovascular catheters for balloon occlusion were placed within the hypogastric arteries, prior to the cesarean section. In the operating room, immediately after the delivery of the baby, bilateral hypogastric arteries were occluded by inflation of the balloons in the catheters previously placed within. With the placenta retained within the uterus, a total hysterectomy was performed in the usual fashion. The occluding balloons were deflated after closure of the vaginal cuff with hemostasis. The patient had stable vital signs and normal laboratory findings during the recovery period; she was discharged six days after delivery without complications. The final pathology confirmed a placenta increta. PMID:20358016

  20. Prophylactic balloon occlusion of internal iliac arteries in women with placenta accreta: Literature review and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dilauro, M.D.; Dason, S. [McMaster University, Michael G. DeGroote School of Medicine (Canada); Athreya, S., E-mail: sathreya@stjoes.ca [Diagnostic Imaging, St Joseph' s Healthcare Hamilton, Ontario (Canada)

    2012-06-15

    Aim: To review the literature on the use of prophylactic balloon occlusion alone and in conjunction with arterial embolization of the internal iliac arteries in women with placenta accreta. Materials and methods: The PubMed, MEDLINE, CINAHL, EMBASE, and Cochrane Library databases were searched for keywords related to this technique and its use in the avoidance of caesarean hysterectomy. The relevant published articles were selected and then searched for further references. Results: The literature search found 15 case reports and five studies for a total of 20 articles. The use of balloon catheters to prevent post-partum haemorrhage in women with placenta accreta is controversial with some investigators reporting reduced blood loss and transfusion requirements while others reporting no benefit. This procedure does not appear to reduce operative time or hospital stay. Some groups have described catheter-related complications, such as maternal thromboembolic events and the need for stent placement and/or arterial bypass. Thus far, there is no reported maternal or foetal mortality related to this procedure. Conclusion: Current evidence is based upon case reports and small retrospective studies. Larger studies or randomized controlled trials are essential in order to demonstrate the safety and efficacy of bilateral iliac balloon occlusion. The creation of a data registry would also facilitate the reporting of this technique.