WorldWideScience

Sample records for backstep scanning ion

  1. Kinesin's backsteps under mechanical load

    CERN Document Server

    Hyeon, Changbong; Onuchic, Jose' N

    2009-01-01

    Kinesins move processively toward the plus end of microtubules by hydrolyzing ATP for each step. From an enzymatic perspective, the mechanism of mechanical motion coupled to the nucleotide chemistry is often well explained using a single-loop cyclic reaction. However, several difficulties arise in interpreting kinesin's backstepping within this framework, especially when external forces oppose the motion of kinesin. We review evidence, such as an ATP-independent stall force and a slower cycle time for backsteps, that has emerged to challenge the idea that kinesin backstepping is due to ATP synthesis, i.e., the reverse cycle of kinesin's forward-stepping chemomechanics. Supplementing the conventional single-loop chemomechanics with routes for ATP-hydrolyzing backward steps and nucleotide-free steps, especially under load, gives a better physical interpretation of the experimental data on backsteps.

  2. Aligned ion implantation using scanning probes

    OpenAIRE

    Persaud, Arun

    2007-01-01

    A new technique for precision ion implantation has been developed. A scanning probe has been equipped with a small aperture and incorporated into an ion beamline, so that ions can be implanted through the aperture into a sample. By using a scanning probe the target can be imaged in a non-destructive way prior to implantation and the probe together with the aperture can be placed at the desired location with nanometer precision. In this work first results of a scanning probe integrated into an...

  3. Aligned ion implantation using scanning probes

    International Nuclear Information System (INIS)

    A new technique for precision ion implantation has been developed. A scanning probe has been equipped with a small aperture and incorporated into an ion beamline, so that ions can be implanted through the aperture into a sample. By using a scanning probe the target can be imaged in a non-destructive way prior to implantation and the probe together with the aperture can be placed at the desired location with nanometer precision. In this work first results of a scanning probe integrated into an ion beamline are presented. A placement resolution of about 120 nm is reported. The final placement accuracy is determined by the size of the aperture hole and by the straggle of the implanted ion inside the target material. The limits of this technology are expected to be set by the latter, which is of the order of 10 nm for low energy ions. This research has been carried out in the context of a larger program concerned with the development of quantum computer test structures. For that the placement accuracy needs to be increased and a detector for single ion detection has to be integrated into the setup. Both issues are discussed in this thesis. To achieve single ion detection highly charged ions are used for the implantation, as in addition to their kinetic energy they also deposit their potential energy in the target material, therefore making detection easier. A special ion source for producing these highly charged ions was used and their creation and interactions with solids of are discussed in detail. (orig.)

  4. Aligned ion implementation using scanning probes

    Energy Technology Data Exchange (ETDEWEB)

    Persaud, A.

    2006-12-12

    A new technique for precision ion implantation has been developed. A scanning probe has been equipped with a small aperture and incorporated into an ion beamline, so that ions can be implanted through the aperture into a sample. By using a scanning probe the target can be imaged in a non-destructive way prior to implantation and the probe together with the aperture can be placed at the desired location with nanometer precision. In this work first results of a scanning probe integrated into an ion beamline are presented. A placement resolution of about 120 nm is reported. The final placement accuracy is determined by the size of the aperture hole and by the straggle of the implanted ion inside the target material. The limits of this technology are expected to be set by the latter, which is of the order of 10 nm for low energy ions. This research has been carried out in the context of a larger program concerned with the development of quantum computer test structures. For that the placement accuracy needs to be increased and a detector for single ion detection has to be integrated into the setup. Both issues are discussed in this thesis. To achieve single ion detection highly charged ions are used for the implantation, as in addition to their kinetic energy they also deposit their potential energy in the target material, therefore making detection easier. A special ion source for producing these highly charged ions was used and their creation and interactions with solids of are discussed in detail. (orig.)

  5. Controlling beam halo-chaos via backstepping design

    Institute of Scientific and Technical Information of China (English)

    Gao Yuan; Kong Feng

    2008-01-01

    A backstepping control method is proposed for controlling beam halo-chaos in the periodic focusing channels PFCs) of high-current ion accelerator. The analysis and numerical results show that the method, via adjusting an exterior magnetic field, is effective to control beam halo chaos with five types of initial distribution ion beams, all statistical quantities of the beam halo-chaos are largely reduced, and the uniformity of ion beam is improved. This control method has an important value of application, for the exterior magnetic field can be easily adjusted in the periodical magnetic focusing channels in experiment.

  6. Scanning Ion Conductance Microscopy of Live Keratinocytes

    Science.gov (United States)

    Hegde, V.; Mason, A.; Saliev, T.; Smith, F. J. D.; McLean, W. H. I.; Campbell, P. A.

    2012-07-01

    Scanning ion conductance microscopy (SICM) is perhaps the least well known technique from the scanning probe microscopy (SPM) family of instruments. As with its more familiar counterpart, atomic force microscopy (AFM), the technique provides high-resolution topographic imaging, with the caveat that target structures must be immersed in a conducting solution so that a controllable ion current may be utilised as the basis for feedback. In operation, this non-contact characteristic of SICM makes it ideal for the study of delicate structures, such as live cells. Moreover, the intrinsic architecture of the instrument, incorporating as it does, a scanned micropipette, lends itself to combination approaches with complementary techniques such as patch-clamp electrophysiology: SICM therefore boasts the capability for both structural and functional imaging. For the present observations, an ICnano S system (Ionscope Ltd., Melbourn, UK) operating in 'hopping mode' was used, with the objective of assessing the instrument's utility for imaging live keratinocytes under physiological buffers. In scans employing cultured HaCaT cells (spontaneously immortalised, human keratinocytes), we compared the qualitative differences of live cells imaged with SICM and AFM, and also with their respective counterparts after chemical fixation in 4% paraformaldehyde. Characteristic surface microvilli were particularly prominent in live cell imaging by SICM. Moreover, time lapse SICM imaging on live cells revealed that changes in the pattern of microvilli could be tracked over time. By comparison, AFM imaging on live cells, even at very low contact forces (scanning speed, however, the intrinsic non-obtrusive nature of

  7. Angular Approach Scanning Ion Conductance Microscopy.

    Science.gov (United States)

    Shevchuk, Andrew; Tokar, Sergiy; Gopal, Sahana; Sanchez-Alonso, Jose L; Tarasov, Andrei I; Vélez-Ortega, A Catalina; Chiappini, Ciro; Rorsman, Patrik; Stevens, Molly M; Gorelik, Julia; Frolenkov, Gregory I; Klenerman, David; Korchev, Yuri E

    2016-05-24

    Scanning ion conductance microscopy (SICM) is a super-resolution live imaging technique that uses a glass nanopipette as an imaging probe to produce three-dimensional (3D) images of cell surface. SICM can be used to analyze cell morphology at nanoscale, follow membrane dynamics, precisely position an imaging nanopipette close to a structure of interest, and use it to obtain ion channel recordings or locally apply stimuli or drugs. Practical implementations of these SICM advantages, however, are often complicated due to the limitations of currently available SICM systems that inherited their design from other scanning probe microscopes in which the scan assembly is placed right above the specimen. Such arrangement makes the setting of optimal illumination necessary for phase contrast or the use of high magnification upright optics difficult. Here, we describe the designs that allow mounting SICM scan head on a standard patch-clamp micromanipulator and imaging the sample at an adjustable approach angle. This angle could be as shallow as the approach angle of a patch-clamp pipette between a water immersion objective and the specimen. Using this angular approach SICM, we obtained topographical images of cells grown on nontransparent nanoneedle arrays, of islets of Langerhans, and of hippocampal neurons under upright optical microscope. We also imaged previously inaccessible areas of cells such as the side surfaces of the hair cell stereocilia and the intercalated disks of isolated cardiac myocytes, and performed targeted patch-clamp recordings from the latter. Thus, our new, to our knowledge, angular approach SICM allows imaging of living cells on nontransparent substrates and a seamless integration with most patch-clamp setups on either inverted or upright microscopes, which would facilitate research in cell biophysics and physiology. PMID:27224490

  8. COMBINED FIELD ION AND SCANNING TUNNELING MICROSCOPE

    OpenAIRE

    Sakurai, T; Hashizurne, T.; Kamiya, I.; Hasegawa, Y.; Sakai, A; Kobayashi, A.; Matsui, J.; Takahashi, S; Kono, E.; Watanabe, H.

    1987-01-01

    Realizing the importance of characterizing a STM probe tip on an atomic scale, we have constructed a new instrument which combines a field ion microscope and scanning tunneling microscope. A complete STM set-up, which is similar to the one developed by Demuth, is mounted on an 8" O.D. flange and a FIM set-up is mounted on a 10" O.D. flange. FI images of the STM probe tip are observed using a 2" O.D. chevron channelplate-image intensifier screen assembly with liquid nitrogen cooling. A field n...

  9. Scanning transmission ion microscopy of polycarbonate nanocapillaries

    International Nuclear Information System (INIS)

    Complete text of publication follows. Nanochanneled materials are of a great interest due to their peculiar properties and high potential impact for the fabrication of nanostructures and nanodevices. Polycarbonate membranes are produced by heavy ion irradiation followed by chemical etching of the ion tracks. The irradiation parameters determine the porosity (areal density of the capillaries) and angular spread, while the channel diameters and shapes depend on the chemical process parameters. Such polycarbonate (and other materials) membranes are commercially available from a few manufacturers. The primary use of the filters involves packaging and filtering applications. Moreover, they are used for collecting atmospheric aerosols for environmental research. The nanocapillaries formed in membranes are particularly suitable for ion and electron guiding studies of a recently discovered, but not yet completely understood capillary guiding phenomenon. This interesting guiding effect is very promising for patterning by parallel writing with ions and/or electrons through masks. In order to get a better understanding of this phenomenon, we need a better characterization of the capillaries themselves. This study is addressing the angular distribution of the nanochannels in the polycarbonate filters by using a nuclear microprobe facility and the method of scanning transmission ion microscopy (STIM). The STIM experiments in this work have been performed at ATOMKI. The proton energy was 2 MeV, the beam intensity was about 1000 protons s-1, the beam spot size was about 1 x 1 μm, the scan size was 100 x 100 μm and the beam divergence was smaller than 0.07 deg. A scanning electron microscope (SEM, Hitachi S4300 CFE) was used to measure the capillary diameters and the membrane porosity. The sample thickness was determined by a profilometer (AMBIOS XP-I). We have investigated two different pieces of Millipore IsoporeTM samples. A typical SEM image showed several overlapping holes

  10. Realization of a scanning ion beam monitor

    International Nuclear Information System (INIS)

    During this thesis, a scanning ion beam monitor has been developed in order to measure on-line fluence spatial distributions. This monitor is composed of an ionization chamber, Hall Effect sensors and a scintillator. The ionization chamber set between the beam exit and the experiment measures the ion rate. The beam spot is localized thanks to the Hall Effect sensors set near the beam sweeping magnets. The scintillator is used with a photomultiplier tube to calibrate the ionization chamber and with an imaging device to calibrate the Hall Effect sensors. This monitor was developed to control the beam lines of a radiobiology dedicated experimentation room at GANIL. These experiments are held in the context of the research in hadron-therapy. As a matter of fact, this new cancer treatment technique is based on ion irradiations and therefore demands accurate knowledge about the relation between the dose deposit in biological samples and the induced effects. To be effective, these studies require an on-line control of the fluence. The monitor has been tested with different beams at GANIL. Fluence can be measured with a relative precision of ±4% for a dose rate ranging between 1 mGy/s and 2 Gy/s. Once permanently set on the beam lines dedicated to radiobiology at GANIL, this monitor will enable users to control the fluence spatial distribution for each irradiation. The scintillator and the imaging device are also used to control the position, the spot shape and the energy of different beams such as those used for hadron-therapy. (author)

  11. Backstepping Strategy for Induction Motor Control

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Vadstrup, P.; Børsting, H.

    2000-01-01

    Using backstepping, which is a recursive nonlinear design method, a novel approach to control of induction motors is developed. The resulting scheme leads to a nonlinear controller for the torque and the amplitude of the field. A combination of nonlinear damping and observer backstepping with a...... simple flux observer is used in the design. Assuming known motor parameters the design achieves stability with guaranteed region of attraction. It is also shown how a conventional field oriented controller may be obtained by omitting parts of the nonlinear controller....

  12. Nanochannel alignment analysis by scanning transmission ion microscopy

    DEFF Research Database (Denmark)

    Rajta, I.; Gál, G.A.B.; Szilasi, S.Z.;

    2010-01-01

    In this paper a study on the ion transmission ratio of a nanoporous alumina sample is presented. The sample was investigated by scanning transmission ion microscopy (STIM) with different beam sizes. The hexagonally close-packed AlO nanocapillary array, realized as a suspended membrane of 15 νm...

  13. Graphitization of polymer surfaces by scanning ion irradiation

    International Nuclear Information System (INIS)

    Graphitization of polymer surfaces was performed by low-energy Ar+ and He+ ion irradiation. A method of scanning irradiation was implemented. It was found that by scanning ion irradiation, a significantly higher electrical conductivity in the graphitized layers can be achieved in comparison with a conventional broad-beam irradiation. The enhancement of the conductance becomes more pronounced for narrower and better collimated ion beams. In order to analyze these results in more detail, the temperature dependence of conductance of the irradiated samples was investigated. The results of measurements are discussed in terms of weak localization corrections to conductance in disordered metals. The observed effects can be explained by enlargement of graphitic patches, which was achieved with the scanning ion irradiation method.

  14. An automated scanning ion microbeam system

    International Nuclear Information System (INIS)

    A standard Russian quadruplet lens system providing a microbeam on a 6 MV Van de Graaff accelerator has been fitted with an automated scanner. Samples housed in a special target chamber can be positioned accurately in two dimensions with respect to the beam. This is achieved by stepping motors. Two pairs of deflection coils provide electromagnetic deflection of the beam in two dimensions and the combination of electrical deflection of the beam and mechanical displacement of the sample permits scanning over a sample area of 10 mm x 10 mm. A staircase current waveform is provided to the coils and data accumulated at each step is routed appropriately to addresses in a large multichannel analyser (computer). The target chamber accommodates particle and X-ray detectors. The electronic operation is controlled by a microprocessor. The requirements of a complete scan are entered through the keyboard and the complete operation including writing of spectral data onto magnetic tape follows automatically. The arrangement has been used to study details of the oxidation behaviour of iron-chromium alloys as part of a larger programme of oxidation studies centred round the 18O (p,α)15 N reaction. (orig.)

  15. An automated scanning ion microbeam system

    Science.gov (United States)

    Requicha Ferreira, L. F.; Calvert, J. M.

    A standard Russian quadruplet lens system providing a microbeam on a 6 MV Van de Graaff accelerator has been fitted with an automated scanner. Samples housed in a special target chamber can be positioned accurately in two dimensions with respect to the beam. This is achieved by stepping motors. Two pairs of deflection coils provide electromagnetic deflection of the beam in two dimensions and the combination of electrical deflection of the beam and mechanical displacement of the sample permits scanning over a sample area of 10 mm × 10 mm. A staircase current waveform is provided to the coils and data accumulated at each step is routed appropriately to addresses in a large multichannel analyser (computer). The target chamber accommodates particle and X-ray detectors. The electronic operation is controlled by a microprocessor. The requirements of a complete scan are entered through the keyboard and the complete operation including writing of spectral data onto magnetic tape follows automatically. The arrangement has been used to study details of the oxidation behaviour of iron-chromium alloys as part of a larger programme of oxidation studies centred round the 18O(p, α) 15N reaction.

  16. Scanning irradiation of polymers by low-energy ions

    International Nuclear Information System (INIS)

    We have already shown that nearly any polymer can be graphitized by low-energy ion irradiation. The surface consists of nanometer-sized graphite/graphene flakes. In order to increase the size of these flakes and to enhance the conductivity of the graphitized surface, we introduce a new method of irradiation. A narrow ion beam is scanned gradually across the polymer surface. Using conductivity vs. temperature measurements, we compare samples produced with different parameters of irradiation, like fluence of ions, speed of scanning, and temperature of the samples. We have observed that a decreased width of the beam correlates to an enhanced conductivity of the surface both at room temperature and at 4.2 K. Compared to flood irradiation the conductivity becomes significantly less temperature dependent. We expect further improvements by optimizing beam width and scanning speed.

  17. Tutorial on nonlinear backstepping: Applications to ship control

    Directory of Open Access Journals (Sweden)

    Thor I. Fossen

    1999-04-01

    Full Text Available The theoretical foundation of nonlinear backstepping designs is presented in a tutorial setting. This includes a brief review of integral backstepping, extensions to SISO and MIMO systems in strict feedback form and physical motivated case studies. Parallels and differences to feedback linearization where it is shown how so-called "good nonlincarities" can be exploited in the design are also made.

  18. Frequency-scanning marginal oscillator for ion cyclotron resonance spectroscopy

    Science.gov (United States)

    Kemper, Paul R.; Bowers, Michael T.

    1982-07-01

    A number of ion cyclotron resonance applications have arisen in the past few years which require a frequency-scanned detection system. Since the traditional marginal oscillator detector has always been a fixed-frequency detector, alternative detection techniques such as bridge circuit detectors have become widely used. In this paper we present an alternative to the bridge detector, namely, a frequency-scanning marginal oscillator. Requirements and modifications necessary to convert a marginal oscillator to frequency scanning operation are discussed in detail and the necessary circuit diagrams presented. Finally, a theoretical comparison is made between bridge circuit and marginal oscillator sensitivities.

  19. Simulating imaging with the scanning ion-conductance microscope.

    Science.gov (United States)

    Adenle, Omolabake; Fitzgerald, William

    2005-01-01

    The Scanning Ion-Conductance Microscope (SICM) is a member of the family of Scanned Probe Microscopes (SPM). Examples include the Scanning Electrochemical Microscope (SECM) and Atomic Force Microscope (AFM). SICM uses the ion-concentration field at the tip of a micropipette filled with an electrolyte solution as a probe to generate images of sample topography. As with other members of the SPM family, the probe geometry determines the observed image. This paper presents mathematical models for simulating the SICM in its different operating modes with the intent of creating a framework within which the effect of probe-geometry can be studied. We validate our model by comparing simulated approach-curves with empirical data. Finally, we show simulated images of a Gaussian-bump substrate under the different operating modes of the SICM. PMID:17280955

  20. Focal depth measurement of scanning helium ion microscope

    International Nuclear Information System (INIS)

    When facing the challenges of critical dimension measurement of complicated nanostructures, such as of the three dimension integrated circuit, characterization of the focal depth of microscopes is important. In this Letter, we developed a method for characterizing the focal depth of a scanning helium ion microscope (HIM) by using an atomic force microscope tip characterizer (ATC). The ATC was tilted in a sample chamber at an angle to the scanning plan. Secondary electron images (SEIs) were obtained at different positions of the ATC. The edge resolution of the SEIs shows the nominal diameters of the helium ion beam at different focal levels. With this method, the nominal shapes of the helium ion beams were obtained with different apertures. Our results show that a small aperture is necessary to get a high spatial resolution and high depth of field images with HIM. This work provides a method for characterizing and improving the performance of HIM.

  1. Scanning ion deep level transient spectroscopy: I. Theory

    International Nuclear Information System (INIS)

    Theoretical aspects of a new technique for the MeV ion microbeam are described in detail for the first time. The basis of the technique, termed scanning ion deep level transient spectroscopy (SIDLTS), is the imaging of defect distributions within semiconductor devices. The principles of SIDLTS are similar to those behind other deep level transient spectroscopy (DLTS) techniques with the main difference stemming from the injection of carriers into traps using the localized energy-loss of a focused MeV ion beam. Energy-loss of an MeV ion generates an electron-hole pair plasma, providing the equivalent of a DLTS trap filling pulse with a duration which depends on space-charge screening of the applied electric field and ambipolar erosion of the plasma for short ranging ions. Some nanoseconds later, the detrapping current transient is monitored as a charge transient. Scanning the beam in conjunction with transient analysis allows the imaging of defect levels. As with DLTS, the temperature dependence of the transient can be used to extract trap activation levels. In this, the first of a two-part paper, we introduce the various stages of corner capture and derive a simple expression for the observed charge transient. The second paper will illustrate the technique on a MeV ion implanted Au-Si Schottky junction

  2. Multiswitching Synchronization of a Driven Hyperchaotic Circuit Using Active Backstepping

    Directory of Open Access Journals (Sweden)

    A. Ayotunde Ajayi

    2014-01-01

    Full Text Available An active backstepping technique is proposed for the realization of multiswitching synchronization of periodically forced hyperchaotic Van der Pol-Duffing oscillators. The active backstepping technique is a systematic design approach with recursive procedures that skillfully optimizes the choice of Lyapunov functions and active control technique. Using the active backstepping technique, the usual master-slave synchronization scheme is extended to study the synchronization of systems with different combinations of the slave states variables with master state variables. Our numerical results confirm the effectiveness of the proposed analytical technique.

  3. Phase modulation mode of scanning ion conductance microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Peng; Zhang, Changlin [State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Liu, Lianqing, E-mail: lqliu@sia.cn, E-mail: gli@engr.pitt.edu; Wang, Yuechao; Yang, Yang [State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016 (China); Li, Guangyong, E-mail: lqliu@sia.cn, E-mail: gli@engr.pitt.edu [Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261 (United States)

    2014-08-04

    This Letter reports a phase modulation (PM) mode of scanning ion conductance microscopy. In this mode, an AC current is directly generated by an AC voltage between the electrodes. The portion of the AC current in phase with the AC voltage, which is the current through the resistance path, is modulated by the tip-sample distance. It can be used as the input of feedback control to drive the scanner in Z direction. The PM mode, taking the advantages of both DC mode and traditional AC mode, is less prone to electronic noise and DC drift but maintains high scanning speed. The effectiveness of the PM mode has been proven by experiments.

  4. Double micropipettes configuration method of scanning ion conductance microscopy

    Science.gov (United States)

    Zhuang, Jian; Li, Zeqing; Jiao, Yangbohan

    2016-07-01

    In this paper, a new double micropipettes configuration mode of scanning ion conductance microscopy (SICM) is presented to better overcome ionic current drift and further improve the performance of SICM, which is based on a balance bridge circuit. The article verifies the feasibility of this new configuration mode from theoretical and experimental analyses, respectively, and compares the quality of scanning images in the conventional single micropipette configuration mode and the new double micropipettes configuration mode. The experimental results show that the double micropipettes configuration mode of SICM has better effect on restraining ionic current drift and better performance of imaging. Therefore, this article not only proposes a new direction of overcoming the ionic current drift but also develops a new method of SICM stable imaging.

  5. A computer program for scanning transmission ion microscopy simulation

    Science.gov (United States)

    Wu, R.; Shen, H.; Mi, Y.; Sun, M. D.; Yang, M. J.

    2005-04-01

    With the installation of the Scanning Proton Microprobe system at Fudan University, we are in the process of developing a three-dimension reconstruction technique based on scanning transmission ion microscopy-computed tomography (STIM-CT). As the first step, a related computer program of STIM simulation has been established. This program is written in the Visual C++®, using the technique of OOP (Object Oriented Programming) and it is a standard multiple-document Windows® program. It can be run with all MS Windows® operating systems. The operating mode is the menu mode, using a multiple process technique. The stopping power theory is based on the Bethe-Bloch formula. In order to simplify the calculation, the improved cylindrical coordinate model was introduced in the program instead of a usual spherical or cylindrical coordinate model. The simulated results of a sample at several rotation angles are presented.

  6. High resolution helium ion scanning microscopy of the rat kidney.

    Directory of Open Access Journals (Sweden)

    William L Rice

    Full Text Available Helium ion scanning microscopy is a novel imaging technology with the potential to provide sub-nanometer resolution images of uncoated biological tissues. So far, however, it has been used mainly in materials science applications. Here, we took advantage of helium ion microscopy to explore the epithelium of the rat kidney with unsurpassed image quality and detail. In addition, we evaluated different tissue preparation methods for their ability to preserve tissue architecture. We found that high contrast, high resolution imaging of the renal tubule surface is possible with a relatively simple processing procedure that consists of transcardial perfusion with aldehyde fixatives, vibratome tissue sectioning, tissue dehydration with graded methanol solutions and careful critical point drying. Coupled with the helium ion system, fine details such as membrane texture and membranous nanoprojections on the glomerular podocytes were visualized, and pores within the filtration slit diaphragm could be seen in much greater detail than in previous scanning EM studies. In the collecting duct, the extensive and striking apical microplicae of the intercalated cells were imaged without the shrunken or distorted appearance that is typical with conventional sample processing and scanning electron microscopy. Membrane depressions visible on principal cells suggest possible endo- or exocytotic events, and central cilia on these cells were imaged with remarkable preservation and clarity. We also demonstrate the use of colloidal gold probes for highlighting specific cell-surface proteins and find that 15 nm gold labels are practical and easily distinguishable, indicating that external labels of various sizes can be used to detect multiple targets in the same tissue. We conclude that this technology represents a technical breakthrough in imaging the topographical ultrastructure of animal tissues. Its use in future studies should allow the study of fine cellular details

  7. Semiconductor characterization by scanning ion beam induced charge (IBIC) microscopy

    CERN Document Server

    Vittone, E; Olivero, P; Manfredotti, C; Jaksic, M; Giudice, A Lo; Fizzotti, F; Colombo, E

    2016-01-01

    The acronym IBIC (Ion Beam Induced Charge) was coined in early 1990's to indicate a scanning microscopy technique which uses MeV ion beams as probes to image the basic electronic properties of semiconductor materials and devices. Since then, IBIC has become a widespread analytical technique to characterize materials for electronics or for radiation detection, as testified by more than 200 papers published so far in peer-reviewed journals. Its success stems from the valuable information IBIC can provide on charge transport phenomena occurring in finished devices, not easily obtainable by other analytical techniques. However, IBIC analysis requires a robust theoretical background to correctly interpret experimental data. In order to illustrate the importance of using a rigorous mathematical formalism, we present in this paper a benchmark IBIC experiment aimed to test the validity of the interpretative model based on the Gunn's theorem and to provide an example of the analytical capability of IBIC to characteriz...

  8. Design New Intelligent PID like Fuzzy Backstepping Controller

    Directory of Open Access Journals (Sweden)

    Arzhang Khajeh

    2014-02-01

    Full Text Available The minimum rule base Proportional Integral Derivative (PID Fuzzy backstepping Controller is presented in this research. The popularity of PID Fuzzy backstepping controller can be attributed to their robust performance in a wide range of operating conditions and partly to their functional simplicity. The process of setting of PID Fuzzy backstepping controller can be determined as an optimization task. Over the years, use of intelligent strategies for tuning of these controllers has been growing. PID methodology has three inputs and if any input is described with seven linguistic values, and any rule has three conditions we will need 7 × 7 × 7 = 343 rules. It is too much work to write 343 rules. In this research the PID-like fuzzy controller can be constructed as a parallel structure of a PD-like fuzzy controller and a PI-like controller to have the minimum rule base. However backstepping controller is work based on cancelling decoupling and nonlinear terms of dynamic parameters of each link, this controller is work based on manipulator dynamic model and this technique is highly sensitive to the knowledge of all parameters of nonlinear robot manipulator’s dynamic equation. This research is used to reduce or eliminate the backstepping controller problem based on minimum rule base fuzzy logic theory to control of flexible robot manipulator system and testing of the quality of process control in the simulation environment of MATLAB/SIMULINK Simulator.

  9. Amplitude Modulation Mode of Scanning Ion Conductance Microscopy.

    Science.gov (United States)

    Li, Peng; Liu, Lianqing; Yang, Yang; Zhou, Lei; Wang, Dong; Wang, Yuechao; Li, Guangyong

    2015-08-01

    Live-cell imaging at the nanoscale resolution is a hot research topic in the field of life sciences for the direct observation of cellular biological activity. Scanning ion conductance microscopy (SICM) is one of the few effective imaging tools for live-cell imaging at the nanoscale resolution. However, there are various problems in existing scanning modes. The hopping and AC modes suffer from low speed, whereas the DC mode is prone to instability because of the DC drift and external electrical interference. In this article, we propose an amplitude modulation (AM) mode of SICM, which employs an AC voltage to enhance the stability and improve the scanning speed. In this AM mode, we introduce a capacitance compensation method to eliminate capacitance effect and use the amplitude of the AC current component to control the tip movement. Experimental results on polydimethylsiloxane samples verify the validity of the AM mode and demonstrate an improved performance of both speed and stability of this new mode. PMID:25759185

  10. How occasional backstepping can speed up a processive motor protein

    CERN Document Server

    Bier, M

    2008-01-01

    Fueled by the hydrolysis of ATP, the motor protein kinesin literally walks on two legs along the biopolymer microtubule. The number of accidental backsteps that kinesin takes appears to be much larger than what one would expect given the amount of free energy that ATP hydrolysis makes available. This is puzzling as more than a billion years of natural selection should have optimized the motor protein for its speed and efficiency. But more backstepping allows for the production of more entropy. Such entropy production will make free energy available. With this additional free energy, the catalytic cycle of the kinesin can be speeded up. We show how measured backstep percentages represent an optimum at which maximal net forward speed is achieved.

  11. Backstepping Controller for Electrically Driven Flexible Joint Manipulator Under Uncertainties

    Directory of Open Access Journals (Sweden)

    Lilia Zouari

    2014-12-01

    Full Text Available The grown complexity of the robot manipulators dynamics taking into account the jointflexibility, parameter uncertainties and unknown bounded disturbances makes conventionalcontrol strategies difficult and complex to synthesize. This paper focuses on the investiga-tion into backstepping control of flexible joint manipulator driving by Brushless DC Motor(BDCM in the presence of parameter uncertainties and unknown bounded disturbances fortracking trajectory. The goal of this paper is to compensate all uncertainties and distur-bances for flexible joint manipulator. To study the effectiveness of the controllers, backstep-ping controller has been developed for position control and an hysteresis controller has beentreated for current control. Simulation results of the response of the flexible joint manipu-lators associated with their controllers have been presented. The high performances of thebackstepping control are examined in terms of tracking accuracy and error reduction.

  12. Scanning electrochemical microscopy of Li-ion batteries.

    Science.gov (United States)

    Ventosa, E; Schuhmann, W

    2015-11-21

    Li-ion batteries (LIBs) are receiving increasing attention over the past decade due to their high energy density. This energy storage technology is expected to continue improving the performance, especially for its large-scale deployment in plug-in hybrid electric vehicles (PHEVs) and full electric vehicles (EVs). Such improvement requires having a large variety of analytical techniques at scientists' disposal in order to understand and address the multiple mechanisms and processes occurring simultaneously in this complex system. This perspective article aims to highlight the strength and potential of scanning electrochemical microscopy (SECM) in this field. After a brief description of a LIB system and the most commonly used techniques in this field, the unique information provided by SECM is illustrated by discussing several recent examples from the literature. PMID:26076998

  13. Observer Backstepping Control for Variable Speed Wind Turbine

    DEFF Research Database (Denmark)

    Galeazzi, Roberto; Gryning, Mikkel Peter Sidoroff; Blanke, Mogens

    2013-01-01

    . The nonlinear controller aims at regulating the generator torque such that an optimal tip-speed ratio can be obtained. Simply relying on the measured rotor angular velocity the proposed observer backstepping controller guarantees global asymptotic tracking of the desired trajectory while maintaining a...

  14. Nonlinear Superheat Control of a Refrigeration Plant using Backstepping

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2008-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The main idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design of...

  15. Adaptive Superheat Control of a Refrigeration Plant using Backstepping

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2008-01-01

    . A new low order nonlinear model of the evaporator is developed and used in a backstepping design of an adaptive nonlinear controller.  The stability of the proposed method is validated theoretically by Lyapunov analysis and experimental results shows the performance of the system for a wide range of...

  16. Integrator backstepping using contraction theory: a brief technological note

    DEFF Research Database (Denmark)

    Jouffroy, Jerome; Lottin, Jacques

    While the use of Lyapunov function candidates for integrator backstepping has been extensively studied in the literature, little research has been conducted regarding the applicability of the so-called incremental stability approaches. This note addresses the problem of the use of an incremental...

  17. Single ion impact detection and scanning probe aligned ion implantation for quantum bit formation

    International Nuclear Information System (INIS)

    Quantum computing and quantum information processing is a promising path to replace classical information processing via conventional computers which are approaching fundamental physical limits. Instead of classical bits, quantum bits (qubits) are utilized for computing operations. Due to quantum mechanical phenomena such as superposition and entanglement, a completely different way of information processing is achieved, enabling enhanced performance for certain problem sets. Various proposals exist on how to realize a quantum bit. Among them are electron or nuclear spins of defect centers in solid state systems. Two such candidates with spin degree of freedom are single donor atoms in silicon and nitrogen vacancy (NV) defect centers in diamond. Both qubit candidates possess extraordinary qualities which makes them promising building blocks. Besides certain advantages, the qubits share the necessity to be placed precisely in their host materials and device structures. A commonly used method is to introduce the donor atoms into the substrate materials via ion implantation. For this, focused ion beam systems can be used, or collimation techniques as in this work. A broad ion beam hits the back of a scanning probe microscope (SPM) cantilever with incorporated apertures. The high resolution imaging capabilities of the SPM allows the non destructive location of device areas and the alignment of the cantilever and thus collimated ion beam spot to the desired implant locations. In this work, this technique is explored, applied and pushed forward to meet necessary precision requirements. The alignment of the ion beam to surface features, which are sensitive to ion impacts and thus act as detectors, is demonstrated. The technique is also used to create NV center arrays in diamond substrates. Further, single ion impacts into silicon device structures are detected which enables deliberate single ion doping.

  18. Single ion impact detection and scanning probe aligned ion implantation for quantum bit formation

    Energy Technology Data Exchange (ETDEWEB)

    Weis, Christoph D.

    2011-10-04

    Quantum computing and quantum information processing is a promising path to replace classical information processing via conventional computers which are approaching fundamental physical limits. Instead of classical bits, quantum bits (qubits) are utilized for computing operations. Due to quantum mechanical phenomena such as superposition and entanglement, a completely different way of information processing is achieved, enabling enhanced performance for certain problem sets. Various proposals exist on how to realize a quantum bit. Among them are electron or nuclear spins of defect centers in solid state systems. Two such candidates with spin degree of freedom are single donor atoms in silicon and nitrogen vacancy (NV) defect centers in diamond. Both qubit candidates possess extraordinary qualities which makes them promising building blocks. Besides certain advantages, the qubits share the necessity to be placed precisely in their host materials and device structures. A commonly used method is to introduce the donor atoms into the substrate materials via ion implantation. For this, focused ion beam systems can be used, or collimation techniques as in this work. A broad ion beam hits the back of a scanning probe microscope (SPM) cantilever with incorporated apertures. The high resolution imaging capabilities of the SPM allows the non destructive location of device areas and the alignment of the cantilever and thus collimated ion beam spot to the desired implant locations. In this work, this technique is explored, applied and pushed forward to meet necessary precision requirements. The alignment of the ion beam to surface features, which are sensitive to ion impacts and thus act as detectors, is demonstrated. The technique is also used to create NV center arrays in diamond substrates. Further, single ion impacts into silicon device structures are detected which enables deliberate single ion doping.

  19. Fast optimization and dose calculation in scanned ion beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hild, S. [Department of Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt (Germany); Department of Radiation Oncology, University Clinic Erlangen and Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen (Germany); Institute for Medical Physics and Radiation Protection, University of Applied Sciences, 35390 Giessen (Germany); Graeff, C.; Trautmann, J.; Kraemer, M. [Department of Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64289 Darmstadt (Germany); Zink, K. [Institute for Medical Physics and Radiation Protection, University of Applied Sciences, 35390 Giessen, Germany and Department of Radiotherapy and Radiooncology, University Hospital Giessen-Marburg, 35043 Marburg (Germany); Durante, M. [Department of Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64289 Darmstadt, Germany and Faculty of Physics, Technische Universität Darmstadt, 64289 Darmstadt (Germany); Bert, C., E-mail: christoph.bert@uk-erlangen.de [Department of Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64289 Darmstadt, Germany and Department of Radiation Oncology, University Clinic Erlangen and Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen (Germany)

    2014-07-15

    Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min.

  20. Fast optimization and dose calculation in scanned ion beam therapy

    International Nuclear Information System (INIS)

    Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min

  1. Adaptive Backstepping Control of Nonlinear Hydraulic-Mechanical System Including Valve Dynamics

    Directory of Open Access Journals (Sweden)

    M. Choux

    2010-01-01

    Full Text Available The main contribution of the paper is the development of an adaptive backstepping controller for a nonlinear hydraulic-mechanical system considering valve dynamics. The paper also compares the performance of two variants of an adaptive backstepping tracking controller with a simple PI controller. The results show that the backstepping controller considering valve dynamics achieves significantly better tracking performance than the PI controller, while handling uncertain parameters related to internal leakage, friction, the orifice equation and oil characteristics.

  2. Modeling and Backstepping Control of the Electronic Throttle System

    Directory of Open Access Journals (Sweden)

    Rui Bai

    2013-01-01

    Full Text Available Electronic throttle is widely used in modern automotive engines. An electronic throttle system regulates the throttle plate angle by using a DC servo motor to adjust the inlet airflow rate of an internal combustion engine. Its application leads to improvements in vehicle drivability, fuel economy, and emissions. In this paper, by taking into account the dynamical behavior of the electronic throttle, the mechanism model is first built, and then the mechanism model is transformed into the state-space model. Based on the state-space model and using the backstepping design technique, a new backstepping controller is developed for the electronic throttle. The proposed controller can make the actual angle of the electronic throttle track its set point with the satisfactory performance. Finally, a computer simulation is performed, and simulation results verify that the proposed control system can achieve favorable tracking performance.

  3. Fuzzy Backstepping Sliding Mode Control for Mismatched Uncertain System

    Directory of Open Access Journals (Sweden)

    H. Q. Hou

    2014-06-01

    Full Text Available Sliding mode controllers have succeeded in many control problems that the conventional control theories have difficulties to deal with; however it is practically impossible to achieve high-speed switching control. Therefore, in this paper an adaptive fuzzy backstepping sliding mode control scheme is derived for mismatched uncertain systems. Firstly fuzzy sliding mode controller is designed using backstepping method based on the Lyapunov function approach, which is capable of handling mismatched problem. Then fuzzy sliding mode controller is designed using T-S fuzzy model method, it can improve the performance of the control systems and their robustness. Finally this method of control is applied to nonlinear system as a case study; simulation results are also provided the performance of the proposed controller.

  4. Backstepping Designs for Aircraft Control - What is there to Gain?

    OpenAIRE

    Härkegård, Ola

    2001-01-01

    Aircraft flight control design is traditionally based on linear control theory, due to the existing wealth of tools for linear design and analysis. However, in order to achieve tactical advantages, modern fighter aircraft strive towards performing maneuvers outside the region where the dynamics of flight are linear, and the need for nonlinear tools arises. In this paper, backstepping is proposed as a possible framework for nonlinear flight control design. Its capabilities of handling five maj...

  5. Output Feedback M-MRAC Backstepping With Aerospace Applications

    Science.gov (United States)

    Stepanyan, Vahram; Krishnakumar, Kalmanje Sriniva

    2014-01-01

    The paper presents a certainty equivalence output feedback backstepping adaptive control design method for the systems of any relative degree with unmatched uncertainties without over-parametrization. It uses a fast prediction model to estimate the unknown parameters, which is independent of the control design. It is shown that the system's input and output tracking errors can be systematically decreased by the proper choice of the design parameters. The approach is applied to aerospace control problems and tested in numerical simulations.

  6. Tracking control of mobile robots: a case study in backstepping

    OpenAIRE

    Jiang, Zhong-Ping; Nijmeijer, Henk

    1997-01-01

    A tracking control methodology via time-varying state feedback based on the backstepping technique is proposed for both a kinematic and simplified dynamic model of a two-degrees-of-freedom mobile robot. We first address the local tracking problem where initial tracking errors are sufficiently small. Then, under additional conditions on the desired velocities, we treat the global tracking problem where initial tracking errors are arbitrary. Simulation results are provided to validate and analy...

  7. Synchronizing two coupled chaotic neurons in external electrical stimulation using backstepping control

    International Nuclear Information System (INIS)

    Backstepping design is a recursive procedure that combines the choice of a Lyapunov function with the design of a controller. In this paper, the backstepping control is used to synchronize two coupled chaotic neurons in external electrical stimulation. The coupled model is based on the nonlinear cable model and only one state variable can be controlled in practice. The backstepping design needs only one controller to synchronize two chaotic systems and it can be applied to a variety of chaotic systems whether they contain external excitation or not, so the two coupled chaotic neurons in external electrical stimulation can be synchronized perfectly by backstepping control. Numerical simulations demonstrate the effectiveness of this design

  8. Synchronizing two coupled chaotic neurons in external electrical stimulation using backstepping control

    Energy Technology Data Exchange (ETDEWEB)

    Deng Bin [School of Electrical and Automation Engineering, Tianjin University, 300072 Tianjin (China); Wang Jiang [School of Electrical and Automation Engineering, Tianjin University, 300072 Tianjin (China)]. E-mail: jiangwang@tju.edu.cn; Fei Xiangyang [School of Electrical and Automation Engineering, Tianjin University, 300072 Tianjin (China)

    2006-07-15

    Backstepping design is a recursive procedure that combines the choice of a Lyapunov function with the design of a controller. In this paper, the backstepping control is used to synchronize two coupled chaotic neurons in external electrical stimulation. The coupled model is based on the nonlinear cable model and only one state variable can be controlled in practice. The backstepping design needs only one controller to synchronize two chaotic systems and it can be applied to a variety of chaotic systems whether they contain external excitation or not, so the two coupled chaotic neurons in external electrical stimulation can be synchronized perfectly by backstepping control. Numerical simulations demonstrate the effectiveness of this design.

  9. Scanning ion deep level transient spectroscopy: II. Ion irradiated Au-Si Schottky junctions

    International Nuclear Information System (INIS)

    Here we introduce a new technique called scanning ion deep level transient spectroscopy (SIDLTS) for the spatial analysis of electrically active defects in devices. In the first part of this paper, a simple theory behind SIDLTS was introduced and factors determining its sensitivity and resolution were discussed. In this paper, we demonstrate the technique on MeV boron implantation induced defects in an Au-Si Schottky junction. SIDLTS measurements are compared with capacitance DLTS measurements over the temperature range, 100-300 K. SIDLTS analyses indicate the presence of two levels, one of which was positively identified as the Ec - 0.23 eV divacancy level. The high sensitivity of SIDLTS is verified and the advantages and limitations of the technique are discussed in light of non-exponential components in the charge transient response. Reasons for several undetected levels are also discussed

  10. 3D Imaging of mammalian cells with ion-abrasion scanning electron microscopy

    OpenAIRE

    Heymann, Jurgen A. W.; Shi, Dan; Kim, Sang; Bliss, Donald; Milne, Jacqueline L. S.; Subramaniam, Sriram

    2008-01-01

    Understanding the hierarchical organization of molecules and organelles within the interior of large eukaryotic cells is a challenge of fundamental interest in cell biology. We are using ion-abrasion scanning electron microscopy (IA-SEM) to visualize this hierarchical organization in an approach that combines focused ion-beam milling with scanning electron microscopy. Here, we extend our previous studies on imaging yeast cells to image subcellular architecture in human melanoma cells and mela...

  11. Experimental Characterization of Secular Frequency Scanning in Ion Trap Mass Spectrometers

    Science.gov (United States)

    Snyder, Dalton T.; Pulliam, Christopher J.; Wiley, Joshua S.; Duncan, Jason; Cooks, R. Graham

    2016-07-01

    Secular frequency scanning is implemented and characterized using both a benchtop linear ion trap and a miniature rectilinear ion trap mass spectrometer. Separation of tetraalkylammonium ions and those from a mass calibration mixture and from a pesticide mixture is demonstrated with peak widths approaching unit resolution for optimized conditions using the benchtop ion trap. The effects on the spectra of ion trap operating parameters, including waveform amplitude, scan direction, scan rate, and pressure are explored, and peaks at black holes corresponding to nonlinear (higher-order field) resonance points are investigated. Reverse frequency sweeps (increasing mass) on the Mini 12 are shown to result in significantly higher ion ejection efficiency and superior resolution than forward frequency sweeps that decrement mass. This result is accounted for by the asymmetry in ion energy absorption profiles as a function of AC frequency and the shift in ion secular frequency at higher amplitudes in the trap due to higher order fields. We also found that use of higher AC amplitudes in forward frequency sweeps biases ions toward ejection at points of higher order parametric resonance, despite using only dipolar excitation. Higher AC amplitudes also increase peak width and decrease sensitivity in both forward and reverse frequency sweeps. Higher sensitivity and resolution were obtained at higher trap pressures in the secular frequency scan, in contrast to conventional resonance ejection scans, which showed the opposite trend in resolution on the Mini 12. Mass range is shown to be naturally extended in secular frequency scanning when ejecting ions by sweeping the AC waveform through low frequencies, a method which is similar, but arguably superior, to the more usual method of mass range extension using low q resonance ejection.

  12. Sliding mode control for an aerodynamic missile based on backstepping design

    Institute of Scientific and Technical Information of China (English)

    Wenjin GU; Hongchao ZHAO; Changpeng PAN

    2005-01-01

    In order to solve the mismatched uncertainties of a class of nonlinear systems,a control method of sliding mode control (SMC) based on the backstepping design is proposed.It introduces SMC in to the last step of backstepping design to modify the backstepping algorithm.This combination not only enables the generalization of the backstepping design to be applied to more general nonlinear systems,but also makes the SMC method become effective in solving the mismatched uncertainties.The SMC based on the backstepping design is applied to the flight control system design of an aerodynamic missile.The control system is researched through simulation.The simulation results show the effectiveness of the proposed control method.

  13. The Reduced-order Design of Robust Adaptive Backstepping Controller

    Institute of Scientific and Technical Information of China (English)

    WUZhao-Jing; XIEXue-Jun; ZHANGSi-Ying

    2005-01-01

    For a class of systems with unmodeled dynamics, robust adaptive stabilization problem is considered in this paper. Firstly, by a series of coordinate changes, the original system is reparameterized. Then, by introducing a reduced-order observer, an error system is obtained. Based on the system, a reduced-order adaptive backstepping controller design scheme is given. It is proved that all the signals in the adaptive control system are globally uniformly bounded, and the regulation error converges to zero asymptotically. Due to the order deduction of the controller, the design scheme in this paper has more practical values. A simulation example further demonstrates the efficiency of the control scheme.

  14. Adaptive Backstepping Control of Lightweight Tower Wind Turbine

    DEFF Research Database (Denmark)

    Galeazzi, Roberto; Borup, Kasper Trolle; Niemann, Hans Henrik;

    2015-01-01

    This paper investigates the feasibility of operating a wind turbine with lightweight tower in the full load region exploiting an adaptive nonlinear controller that allows the turbine to dynamically lean against the wind while maintaining nominal power output. The use of lightweight structures for...... towers and foundations would greatly reduce the construction cost of the wind turbine, however extra features ought be included in the control system architecture to avoid tower collapse. An adaptive backstepping collective pitch controller is proposed for tower point tracking control, i.e. to modify the...

  15. Recursive Backstepping Stabilization of a Wheeled Mobile Robot

    Directory of Open Access Journals (Sweden)

    Faical Mnif

    2008-11-01

    Full Text Available This research is aimed to the development of a dynamic control to enhance the performance of the existing dynamic controllers for mobile robots. System dynamics of the car-like robot with nonholonomic constraints were employed. A Backstepping approach for the design of discontinuous state feedback controller is used for the design of the controller. It is shown that the origin of the closed loop system can be made stable in the sense of Lyapunov. The control design is made on the basis of a suitable Lyapunov function candidate. The effectiveness of the proposed approach is tested through simulation on a car-like vehicle mobile robot.

  16. High resolution imaging using scanning ion conductance microscopy with improved distance feedback control

    Institute of Scientific and Technical Information of China (English)

    Chao Li; Nicholas Johnson; Victor Ostanin; Andrew Shevchuk; Liming Ying; Yuri Korchev; David Klenerman

    2008-01-01

    Microscopy is an essential technique for observation on living cells. There is currently great interest in applying scanning probe microscopy to image-living biological cells in their natural environment at the nanometer scale. Scanning ion conductance microscopy is a new form of scanning probe microscopy, which enables non-contact high-resolution imaging of living biological cells. Based on a scanned nanopipette in physiological buffer, the distance feedback control uses the ion current to control the distance between the pipette tip and the sample surface. However, this feedback control has difficulties over slopes on convoluted cell surfaces, which limits its resolution. In this study, we present an improved form of feedback control that removes the contribution of up to the third-order slope from the ion current signal, hence providing a more accurate signal for controlling the distance. We show that this allows faster and lower noise topographic high-resolution imaging.

  17. Depth scanning for a conformal ion beam treatment of deep seated tumours

    International Nuclear Information System (INIS)

    Only target-conformal treatment allows one to exploit the advantages of ion beams (the increased dose and high biological efficiency at the end of the particle range) to a maximum extent. Up to now, target-conformal treatments such as spot scanning or intensity-controlled raster scanning have used fast magnetic lateral deflection in one or two directions perpendicular to the beam axis and a slow range variation in the longitudinal axis by active or passive energy variation. The present paper describes a new method for conformal irradiation with a fast intensity-controlled longitudinal scan in the beam direction, called 'depth scanning'. Its advantages and disadvantages will be discussed. First experimental results from depth scanning will be presented. Only target-conformal treatment allows one to exploit the advantages of ion beams (the increased dose and high biological efficiency at the end of the particle range) to a maximum extent. Up to now, target-conformal treatments such as spot scanning or intensity-controlled raster scanning have used fast magnetic lateral deflection in one or two directions perpendicular to the beam axis and a slow range variation in the longitudinal axis by active or passive energy variation. The present paper describes a new method for conformal irradiation with a fast intensity-controlled longitudinal scan in the beam direction, called 'depth scanning'. Its advantages and disadvantages will be discussed. First experimental results from depth scanning will be presented. (author)

  18. Dark-Field Scanning Transmission Ion Microscopy via Detection of Forward-Scattered Helium Ions with a Microchannel Plate.

    Science.gov (United States)

    Woehl, Taylor J; White, Ryan M; Keller, Robert R

    2016-06-01

    A microchannel plate was used as an ion sensitive detector in a commercial helium ion microscope (HIM) for dark-field transmission imaging of nanomaterials, i.e. scanning transmission ion microscopy (STIM). In contrast to previous transmission HIM approaches that used secondary electron conversion holders, our new approach detects forward-scattered helium ions on a dedicated annular shaped ion sensitive detector. Minimum collection angles between 125 mrad and 325 mrad were obtained by varying the distance of the sample from the microchannel plate detector during imaging. Monte Carlo simulations were used to predict detector angular ranges at which dark-field images with atomic number contrast could be obtained. We demonstrate atomic number contrast imaging via scanning transmission ion imaging of silica-coated gold nanoparticles and magnetite nanoparticles. Although the resolution of STIM is known to be degraded by beam broadening in the substrate, we imaged magnetite nanoparticles with high contrast on a relatively thick silicon nitride substrate. We expect this new approach to annular dark-field STIM will open avenues for more quantitative ion imaging techniques and advance fundamental understanding of underlying ion scattering mechanisms leading to image formation. PMID:27153003

  19. Charting molecular composition of phosphatidylcholines by fatty acid scanning and ion trap MS3 fragmentation

    DEFF Research Database (Denmark)

    Ekroos, Kim; Ejsing, Christer S.; Bahr, Ute;

    2003-01-01

    preliminary separation of lipid classes or of individual molecular species, enzymatic digestion, or chemical derivatization. The approach was validated by the comparative analysis of the molecular composition of PCs from human red blood cells. In the total lipid extract of Madin-Darby canine kidney II cells......The molecular composition of phosphatidylcholines (PCs) in total lipid extracts was characterized by a combination of multiple precursor ion scanning on a hybrid quadrupole time-of-flight mass spectrometer and MS3 fragmentation on an ion trap mass spectrometer. Precursor ion spectra for 50 acyl...... anion fragments of fatty acids (fatty acid scanning) acquired in parallel increased the specificity and the dynamic range of the detection of PCs and identified the fatty acid moieties in individual PC species. Subsequent analysis of detected PC peaks by MS3 fragmentation on an ion trap mass...

  20. Scanning ion conductance microscopy measurement of paracellular channel conductance in tight junctions

    OpenAIRE

    Chen, Chiao-Chen; Zhou, Yi; Morris, Celeste A.; Hou, Jianghui; Baker, Lane A.

    2013-01-01

    Elucidation of epithelial transport across transcellular or paracellular pathways promises to advance the present understanding of ion transport and enables regulation of cell junctions critical to the cell and molecular biology of the epithelium. Here we demonstrate a new instrumental technique potentiometric scanning ion conductance microscopy (P-SICM) that utilizes a nanoscale pipette to differentiate paracellular and transcellular transport processes at high spatial resolution. The techni...

  1. Control of Higher–Dimensional PDEs Flatness and Backstepping Designs

    CERN Document Server

    Meurer, Thomas

    2013-01-01

    This monograph presents new model-based design methods for trajectory planning, feedback stabilization, state estimation, and tracking control of distributed-parameter systems governed by partial differential equations (PDEs). Flatness and backstepping techniques and their generalization to PDEs with higher-dimensional spatial domain lie at the core of this treatise. This includes the development of systematic late lumping design procedures and the deduction of semi-numerical approaches using suitable approximation methods. Theoretical developments are combined with both simulation examples and experimental results to bridge the gap between mathematical theory and control engineering practice in the rapidly evolving PDE control area. The text is divided into five parts featuring: - a literature survey of paradigms and control design methods for PDE systems - the first principle mathematical modeling of applications arising in heat and mass transfer, interconnected multi-agent systems, and piezo-actuated smar...

  2. Backstepping controller of five-level three-phase inverter

    Directory of Open Access Journals (Sweden)

    Majdoul R.

    2014-01-01

    Full Text Available Multilevel converters are becoming increasingly used in many industrial applications due to the many advantages that they offer. The improvements in the output signal quality, lower Total Harmonic Distortion (THD and many other properties make multilevel converters very attractive for connecting photovoltaic generators to medium voltage grid directly or to be used in a local power supply. In this paper, we focus on the implementation of a three-phase five-level diode clamped inverter and design of a performing nonlinear controller using the Backstepping approach. The control objective is to generate, at the system output, sinusoidal three-phase voltages with amplitude and frequency fixed by the reference signal independently of load variations. The performance study of the multilevel inverter and the designed controller are made by simulations in Matlab/Simulink environment.

  3. Backstepping Adaptive Controller of Electro-Hydraulic Servo System of Continuous Rotary Motor

    Institute of Scientific and Technical Information of China (English)

    XiaoJing Wang; ChangFu Xian; CaoLei Wan; JinBao Zhao; LiWei Xiu; AnCai Yu

    2014-01-01

    In order to consider the influence of the continuous rotary motor electro-hydraulic servo system parameters change on its performance, the design method of backstepping adaptive controller is put forward. The mathematical model of electro-hydraulic servo system of continuous rotary motor is established, and the whole system is decomposed into several lower order subsystems, and the virtual control signal is designed for each subsystem from the final subsystem with motor angular displacement to the subsystem with system control input voltage. Based on Lyapunov method and the backstepping theory, an adaptive backstepping controller is designed with the changed parameters adaptive law. It is proved that the system reaches the global asymptotic stability, and the system tracking error asymptotically tends to zero. The simulation results show that the backstepping adaptive controller based on the adaptive law of the changed parameters can improve the performance of continuous rotary motor, and the proposed control strategy is feasible.

  4. Optimisation of the ion optical range adaptation method for tracking of moving tumours with scanned ion beams

    International Nuclear Information System (INIS)

    Currently an ion optical solution for beam tracking of moving targets with scanned ion beams is being investigated at GSI for the treatment of moving tumours, such as lung cancer. Beam tracking compensates target motion by adapting the lateral beam position as well as the beam range according to the motion parameters. Tracking of the lateral position is achieved via scanning magnets. For range adaptation the proposed ion optical solution uses an energy degrader with variable thickness inserted into the therapy beam line downstream of the synchrotron. By deflecting the particle beam via dipole magnets to different positions on the degrader, the range of the Bragg peak can be adjusted in real-time. Hence density changes due to organ motion can be compensated for each target spot during beam scanning. In order to reach a beam quality suitable for therapy with this method, systematic studies on the ion optical parameters have to be carried out. Different degrader designs (ramp or discrete step shaped), different materials (e.g. PMMA, graphite), as well as optimised degrader positions have been examined. The results of simulated beam profiles are presented.

  5. Focused Ion Beam - Scanning Electron Microscopy Applied to Electrically Insulating Materials

    NARCIS (Netherlands)

    de Winter, D.A.M.

    2015-01-01

    The Focused Ion Beam – Scanning Electron Microscope (FIB-SEM) is a versatile instrument originating from the semiconductor industry. The FIB is used to produce cross sections of pre-defined locations of interest, which are imaged and analyzed with the SEM. Repeated FIB cross sectioning and subsequen

  6. DEVELOPMENT OF THE FIELD ION-SCANNING TUNNELING MICROSCOPE AND ITS APPLICATIONS

    OpenAIRE

    Kamiya, I.; Sakurai, T

    1989-01-01

    A scanning tunneling microscope (STM) equipped with a field ion microscope (FIM) which operates at room temperature has been constructed and operated successfully to obtain atomically resolved STM images with 100% reproductibility. This instrument, which we call the FI-STM, has been employed for the quantitative study of the Si(100) "2xn" phase.

  7. Adaptive Backstepping controller design and implementation for a matrix-converter-based IM drive system

    OpenAIRE

    R.R. Joshi; R.A. Gupta; A.K. Wadhwani

    2007-01-01

    A systematic controller design and implementation for a matrix-converter-based induction motor drive system is proposed. A nonlinear adaptive backstepping controller is proposed to improve the speed and position responses of the induction motor system. By using the proposed adaptive backstepping controller, the system can track a time-varying speed command and a time-varying position command well. Moreover, the system has a good load disturbance rejection capability. The realization of the co...

  8. Dynamic surface control-backstepping based impedance control for 5-DOF flexible joint robots

    Institute of Scientific and Technical Information of China (English)

    XIONG Gen-liang; XIE Zong-wu; HUANG Jian-bin; LIU Hong; JIANG Zai-nan; SUN Kui

    2010-01-01

    A new impedance controller based on the dynamic surface control-backstepping technique to actualize the anticipant dynamic relationship between the motion of end-effector and the external torques was presented.Comparing with the traditional backstepping method that has"explosion of terms"problem,the new proposed control system is a combination of the dynamic surface control technique and the backstepping.The dynamic surface control(DSC)technique can resolve the"explosion of terms"problem that is caused by differential coefficient calculation in the model,and the problem can bring a complexity that will cause the backstepping method hardly to be applied to the practical application,especially to the multi-joint robot.Finally,the validity of the method was proved in the laboratory environment that was set up on the 5-DOF(degree of freedom)flexible joint robot.Tracking errors of DSC-backstepping impedance control that were 2.0 and 1.5 mm are better than those of backstepping impedance control which were 3.5 and 2.5 nun in directions X,Y in free space,respectively.And the anticipant Cartesian impedance behavior and compliant behavior were achieved successfully as depicted theoretically.

  9. Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Marinelli, Marco; Prestopino, G., E-mail: giuseppe.prestopino@uniroma2.it; Verona, C.; Verona-Rinati, G. [INFN—Dipartimento di Ingegneria Industriale, Università di Roma “Tor Vergata,” Via del Politecnico 1, Roma 00133 (Italy); Ciocca, M.; Mirandola, A.; Mairani, A. [Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy); Raffaele, L. [INFN—Laboratori Nazionali del Sud, Via S. Sofia 62, Catania 95123, Italy and Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy); Magro, G. [INFN—Dipartimento di Fisica, Università degli Studi di Pavia, Via U. Bassi 6, Pavia 27100, Italy and Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy)

    2015-04-15

    Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam

  10. Development of scanning transmission ion microscopy computed tomography at Fudan Microbeam line

    International Nuclear Information System (INIS)

    The computed tomography was applied to setting STIM (Scanning Transmission Ion Microscopy) projections recorded at the Fudan Ion Beam Laboratory. In this work, in order to visualize the three-dimensional mass density distribution in several specimens, example for a test structure of hollow gold cylinder was presented together with a detailed description of the developed system, including data reconstruction code (Tomorebuild 2) and image display software (AMIRA®). Future development will allow the particle induced X-ray emission tomography for elemental analysis of micrometer-sized samples. (authors)

  11. The role of flux-focusing in the origin of shoulders in ion channeling angular scans

    International Nuclear Information System (INIS)

    We have investigated the effect of ion channeling flux-focusing on the origin of high near-surface shoulders in channeling angular scans of single crystals. We simulate 2 MeV He ion planar channeling in Si{100} and analyze the variation of ion flux distribution within the channel with respect to the angle of incidence. It is observed that at the angle of incidence corresponding to the channeling shoulder, the primary channeling focus overlaps with lattice atoms and dramatically enhances the ion flux density at atomic sites, increasing the ion–atom close encounter probability. We show that the so increased close encounter probability originates high near-surface shoulders in channeling. -- Highlights: ► We study the effect of ion flux-focusing on origin of channeling shoulders. ► We simulate variation of ion channeling flux focus with incidence angle. ► Near channeling critical angle, flux focus superimposes on atomic sites. ► Ion flux focus superposition with atomic sites originates shoulders.

  12. Surface damage through grazing incidence ions investigated by scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Redinger, Alex

    2009-07-10

    Surface damage, caused by grazing incidence ions, is investigated with variable temperature scanning tunneling microscopy. The experiments are carried out on a Pt(111) crystal. The kinetic energy of noble gas ions is varied between 1-15 keV and the angle of incidence can be adjusted between {theta} = 78.5 and {theta} = 90 measured with respect to the surface normal. The damage patterns of single ion impacts, on flat terraces and at step edges of monoatomic height, are investigated at low surface temperatures. Ions hitting a flat terrace are usually specular reflected. The energy transfer from the ion to the crystal atoms is small and only little damage is produced. In contrast, at ascending step edges, which are illuminated by the ion beam, large angle scattering events occur. Sputtering, adatom and vacancy production is induced. However, a significant fraction of the ions, which hit step edges, enter the crystal and are guided in between two atomic layers parallel to the surface via small angle binary collisions. This steering process is denoted as subsurface channeling. The energy loss per length scale of the channeled particles is low, which results in long ion trajectories (up to 1000A). During the steering process, the ions produce surface damage. Depending on the ion species and the ion energy, adatom and vacancies or surface vacancy trenches of monoatomic width are observed. The surface damage can be used to track the path of the ion. This makes the whole trajectory of single ions with keV energy visible. The number of sputtered atoms per incident ion at ascending step edges, i.e. the step edge sputtering yield, is measured experimentally for different irradiation conditions. For {theta} = 86 , the sputtering yield is determined from the fluence dependent retraction of pre-existing illuminated step edges. An alternative method for the step edge sputtering yield determination, is the analysis of the concentration of ascending steps and of the removed amount

  13. Surface damage through grazing incidence ions investigated by scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Surface damage, caused by grazing incidence ions, is investigated with variable temperature scanning tunneling microscopy. The experiments are carried out on a Pt(111) crystal. The kinetic energy of noble gas ions is varied between 1-15 keV and the angle of incidence can be adjusted between θ = 78.5 and θ = 90 measured with respect to the surface normal. The damage patterns of single ion impacts, on flat terraces and at step edges of monoatomic height, are investigated at low surface temperatures. Ions hitting a flat terrace are usually specular reflected. The energy transfer from the ion to the crystal atoms is small and only little damage is produced. In contrast, at ascending step edges, which are illuminated by the ion beam, large angle scattering events occur. Sputtering, adatom and vacancy production is induced. However, a significant fraction of the ions, which hit step edges, enter the crystal and are guided in between two atomic layers parallel to the surface via small angle binary collisions. This steering process is denoted as subsurface channeling. The energy loss per length scale of the channeled particles is low, which results in long ion trajectories (up to 1000A). During the steering process, the ions produce surface damage. Depending on the ion species and the ion energy, adatom and vacancies or surface vacancy trenches of monoatomic width are observed. The surface damage can be used to track the path of the ion. This makes the whole trajectory of single ions with keV energy visible. The number of sputtered atoms per incident ion at ascending step edges, i.e. the step edge sputtering yield, is measured experimentally for different irradiation conditions. For θ = 86 , the sputtering yield is determined from the fluence dependent retraction of pre-existing illuminated step edges. An alternative method for the step edge sputtering yield determination, is the analysis of the concentration of ascending steps and of the removed amount of material as a

  14. Scanning Auger Microscopy of laser-produced Cu ions implanted in silicon

    Czech Academy of Sciences Publication Activity Database

    Mezzasalma, A. M.; Torrisi, L.; Gammino, S.; Mondio, G.; Franco, G.; Wolowski, J.; Parys, P.; Badziak, J.; Krása, Josef; Láska, Leoš

    Frascati : C. R. ENEA Frascati, 2005 - (Strangio, C.), x [ECLIM 2004: European Conference on Laser Interaction with Matter /28./. Roma (IT), 06.09.2004-10.09.2004] R&D Projects: GA MŠk(CZ) LN00A100 Institutional research plan: CEZ:AV0Z10100523 Keywords : ion implantation * pulsed laser irradiation * Scanning Auger Microscopy Subject RIV: BH - Optics, Masers, Lasers

  15. Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma – feasibility and clinical response

    International Nuclear Information System (INIS)

    Photon-based radiation therapy does currently not play a major role as local ablative treatment for hepatocellular carcinoma (HCC). Carbon ions offer distinct physical and biological advantages. Due to their inverted dose profile and the high local dose deposition within the Bragg peak, precise dose application and sparing of normal tissue is possible. Furthermore, carbon ions have an increased relative biological effectiveness (RBE) compared to photons. A total of six patients with one or more HCC-lesions were treated with carbon ions delivered by the raster-scanning technique according to our clinical trial protocol. Diagnosis of HCC was confirmed by histology or two different imaging modalities (CT and MRI) according to the AASLD-guidelines. Applied fractionation scheme was 4 × 10 Gy(RBE). Correct dose application was controlled by in-vivo PET measurement of β + −activity in the irradiated tissue shortly after treatment. Patients were observed for a median time period of 11.0 months (range, 3.4 – 12.7 months). Imaging studies showed a partial response in 4/7 lesions and a stable disease in 3/7 lesions in follow-up CT- and MRI scans. Local control was 100%. One patient with multifocal intrahepatic disease underwent liver transplantation 3 months after carbon ion therapy. During radiotherapy and the follow-up period no severe adverse events have occurred. We report the first clinical results of patients with HCC undergoing carbon ion therapy using the rasterscanning technique at our institution. All patients are locally controlled and experienced no higher toxicities in a short follow-up period. Further patients will be included in our prospective Phase-I clinical trial PROMETHEUS-01 (NCT01167374)

  16. Screening and identification of glyceollins and their metabolites by electrospray ionization tandem mass spectrometry with precursor ion scanning

    Science.gov (United States)

    A method has been developed for screening glyceollins and their metabolites based upon precursor ion scanning. Under higher-energy collision conditions, employing a triple quadrupole mass spectrometer in the negative ion mode, deprotonated glyceollin precursors yield a diagnostic radical product ion...

  17. Experimental investigations on carbon ion scanning radiography using a range telescope.

    Science.gov (United States)

    Rinaldi, I; Brons, S; Jäkel, O; Voss, B; Parodi, K

    2014-06-21

    Ion beams offer an excellent tumor-dose conformality due to their inverted depth-dose profile and finite range in tissue, the Bragg peak (BP). However, they introduce sensitivity to range uncertainties. Imaging techniques play an increasingly important role in ion beam therapy to support precise diagnosis and identification of the target volume at the planning stage as well as to ensure the correspondence between the planning and treatment situation at the actual irradiation. For the purpose of improved treatment quality, ion-based radiographic images could be acquired at the treatment site before or during treatment and be employed to monitor the patient positioning and to check the patient-specific ion range. This work presents the initial experimental investigations carried out to address the feasibility of carbon ion radiography at the Heidelberg ion therapy center using a prototype range telescope set-up and an active raster scanning ion beam delivery system. Bragg curves are measured with a stack of ionization chambers (IC) synchronously to the beam delivery. The position of the BP is extracted from the data by locating the channel of maximum current signal for each delivered beam. Each BP is associated to the lateral and vertical positions of the scanned raster point extrapolated from the beam monitor system to build up a radiography. The radiographic images are converted into water equivalent thickness (WET) based on two calibrations of the detector. Radiographies of two phantoms of different complexities are reconstructed and their image quality is analyzed. A novel method proposed to increase the nominal range resolution of the IC stack is applied to the carbon ion radiography of an Alderson head phantom. Moreover, an x-ray digitally reconstructed radiography of the same anthropomorphic head phantom is converted in WET through the clinically used ion range calibration curve and compared with the carbon ion radiography based on a γ-index approach

  18. Backstepping-Based Inverse Optimal Attitude Control of Quadrotor

    Directory of Open Access Journals (Sweden)

    An Honglei

    2013-05-01

    Full Text Available Input saturation must be taken into account for applying rapid reorientation in the large angle manoeuvre of a quadrotor. In this paper, a backstepping‐based inverse optimal attitude controller (BIOAC is derived which has the property of a maximum convergence rate in the sense of a control Lyapunov function (CLF under input torque limitation. In the controller, a backstepping technique is used for handling the complexity introducing by the unit quaternion representation of the attitude of a quadrotor with four parameters. Moreover, the inverse optimal approach is employed to circumvent the difficulty of solving the Hamilton‐Jacobi‐Bellman (HJB equation. The performance of BIOAC is compared with a PD controller in which the input torque limitation is not considered under the same unit quaternion representation using numerical simulation while the results show that BIOAC gains faster convergence with less control effort. Next, BIOAC is realized on a test bed and the effectiveness of the control law is verified by experimental studies.

  19. Design High-Efficiency Intelligent PID like Fuzzy Backstepping Controller for Three Dimension Motor

    Directory of Open Access Journals (Sweden)

    Mahsa Piltan

    2014-08-01

    Full Text Available The minimum rule base Proportional Integral Derivative (PID Fuzzy backstepping Controller for three dimensions spherical motor is presented in this research. The popularity of PID Fuzzy backstepping controller can be attributed to their robust performance in a wide range of operating conditions and partly to their functional simplicity. The process of setting of PID Fuzzy backstepping controller can be determined as an optimization task. Over the years, use of intelligent strategies for tuning of these controllers has been growing. PID methodology has three inputs and if any input is described with seven linguistic values, and any rule has three conditions we will need 7 × 7 × 7 = 343 rules. It is too much work to write 343 rules. In this research the PID-like fuzzy controller can be constructed as a parallel structure of a PI-like controller and a PD-like fuzzy controller to have the minimum rule base. However backstepping controller is work based on cancelling decoupling and nonlinear terms of dynamic parameters of each dimension, this controller is work based on spherical motor dynamic model and this technique is highly sensitive to the knowledge of all parameters of nonlinear three dimension spherical motor’s dynamic equation. This research is used to reduce or eliminate the backstepping controller problem based on minimum rule base fuzzy logic theory to control of spherical motor system and testing of the quality of process control in the simulation environment of MATLAB/SIMULINK Simulator.

  20. Hydrogen and oxygen behaviors on Porous-Si surfaces observed using a scanning ESD ion microscope

    International Nuclear Information System (INIS)

    A scanning electron-stimulated desorption (ESD) ion microscope (SESDIM) measured the 2-D images of hydrogen and oxygen distribution on solid surfaces. A primary electron beam at 600 eV, with a pulse width of 220 ns, resulted in ion yields of H+ and O+. This SESDIM is applied to the surface analysis of Porous-Si (Po-Si) partially covered with SiN films. During the heating of a specimen of the Po-Si at 800 deg. C under ultra-high-vacuum (UHV) conditions, the components of the surface materials were moved or diffused by thermal decomposition accompanied by a redistribution of hydrogen and oxygen. After cyclic heating of above 800 deg. C, the dynamic behaviors of H+ and O+ accompanied by the movements of the SiN layers were observed as images of H+ and O+. This was because the H+ and O+ ions have been identified as composite materials by their kinetic energies

  1. Adaptive variable structure control based on backstepping for spacecraft with reaction wheels during attitude maneuver

    Institute of Scientific and Technical Information of China (English)

    SONG Bin; MA Guang-fu; LI Chuan-jiang

    2009-01-01

    An adaptive variable structure control method based on backstepping is proposed for the attitude maneuver problem of rigid spacecraft with reaction wheel dynamics in the presence of uncertain inertia matrix and external disturbances. The proposed control approach is a combination of the backstepping and the adaptive variable structure control. The cascaded structure of the attitude maneuver control system with reaction wheel dynamics gives the advantage for applying the backstepping method to construct Lyapunov functions. The robust stability to external disturbances and parametric uncertainty is guaranteed by the adaptive variable structure control. To validate the proposed control algorithm, numerical simulations using the proposed approach are performed for the attitude maneuver mission of rigid spacecraft with a configuration consisting of four reaction wheels for actuator and three magnetorquers for momentum unloading. Simulation results verify the effectiveness of the proposed control algorithm.

  2. Identification-based chaos control via backstepping design using self-organizing fuzzy neural networks

    International Nuclear Information System (INIS)

    This paper proposes an identification-based adaptive backstepping control (IABC) for the chaotic systems. The IABC system is comprised of a neural backstepping controller and a robust compensation controller. The neural backstepping controller containing a self-organizing fuzzy neural network (SOFNN) identifier is the principal controller, and the robust compensation controller is designed to dispel the effect of minimum approximation error introduced by the SOFNN identifier. The SOFNN identifier is used to online estimate the chaotic dynamic function with structure and parameter learning phases of fuzzy neural network. The structure learning phase consists of the growing and pruning of fuzzy rules; thus the SOFNN identifier can avoid the time-consuming trial-and-error tuning procedure for determining the neural structure of fuzzy neural network. The parameter learning phase adjusts the interconnection weights of neural network to achieve favorable approximation performance. Finally, simulation results verify that the proposed IABC can achieve favorable tracking performance.

  3. Parametric adaptive estimation and backstepping control of electro-hydraulic actuator with decayed memory filter.

    Science.gov (United States)

    Guo, Qing; Sun, Ping; Yin, Jing-Min; Yu, Tian; Jiang, Dan

    2016-05-01

    Some unknown parameter estimation of electro-hydraulic system (EHS) should be considered in hydraulic controller design due to many parameter uncertainties in practice. In this study, a parametric adaptive backstepping control method is proposed to improve the dynamic behavior of EHS under parametric uncertainties and unknown disturbance (i.e., hydraulic parameters and external load). The unknown parameters of EHS model are estimated by the parametric adaptive estimation law. Then the recursive backstepping controller is designed by Lyapunov technique to realize the displacement control of EHS. To avoid explosion of virtual control in traditional backstepping, a decayed memory filter is presented to re-estimate the virtual control and the dynamic external load. The effectiveness of the proposed controller has been demonstrated by comparison with the controller without adaptive and filter estimation. The comparative experimental results in critical working conditions indicate the proposed approach can achieve better dynamic performance on the motion control of Two-DOF robotic arm. PMID:26920086

  4. Millimeter length micromachining using a heavy ion nuclear microprobe with standard magnetic scanning

    International Nuclear Information System (INIS)

    In order to increase the scanning length of our microprobe, we have developed an irradiation procedure suitable for use in any nuclear microprobe, extending at least up to 400% the length of our heavy ion direct writing facility using standard magnetic exploration. Although this method is limited to patterns of a few millimeters in only one direction, it is useful for the manufacture of curved waveguides, optical devices such Mach–Zehnder modulators, directional couplers as well as channels for micro-fluidic applications. As an example, this technique was applied to the fabrication of 3 mm 3D-Mach–Zehnder modulators in lithium niobate with short Y input/output branches and long shaped parallel-capacitor control electrodes. To extend and improve the quality of the machined structures we developed new scanning control software in LabView™ platform. The new code supports an external dose normalization, electrostatic beam blanking and is capable of scanning figures at 16 bit resolution using a National Instruments™ PCI-6731 High-Speed I/O card. A deep and vertical micromachining process using swift 35Cl ions 70 MeV bombarding energy and direct write patterning was performed on LiNbO3, a material which exhibits a strong natural anisotropy to conventional etching. The micromachined structures show the feasibility of this method for manufacturing micro-fluidic channels as well

  5. Millimeter length micromachining using a heavy ion nuclear microprobe with standard magnetic scanning

    Energy Technology Data Exchange (ETDEWEB)

    Nesprías, F. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Debray, M.E., E-mail: debray@tandar.cnea.gov.ar [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Escuela de Ciencia y Tecnología. Universidad Nacional de Gral. San Martín, M. De Irigoyen 3100 (1650), San Martín, Buenos Aires (Argentina); Davidson, J. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); CONICET, Avda. Rivadavia 1917 (C1033AAJ), Ciudad Autónoma de Buenos Aires (Argentina); Kreiner, A.J. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Escuela de Ciencia y Tecnología. Universidad Nacional de Gral. San Martín, M. De Irigoyen 3100 (1650), San Martín, Buenos Aires (Argentina); CONICET, Avda. Rivadavia 1917 (C1033AAJ), Ciudad Autónoma de Buenos Aires (Argentina); and others

    2013-04-01

    In order to increase the scanning length of our microprobe, we have developed an irradiation procedure suitable for use in any nuclear microprobe, extending at least up to 400% the length of our heavy ion direct writing facility using standard magnetic exploration. Although this method is limited to patterns of a few millimeters in only one direction, it is useful for the manufacture of curved waveguides, optical devices such Mach–Zehnder modulators, directional couplers as well as channels for micro-fluidic applications. As an example, this technique was applied to the fabrication of 3 mm 3D-Mach–Zehnder modulators in lithium niobate with short Y input/output branches and long shaped parallel-capacitor control electrodes. To extend and improve the quality of the machined structures we developed new scanning control software in LabView™ platform. The new code supports an external dose normalization, electrostatic beam blanking and is capable of scanning figures at 16 bit resolution using a National Instruments™ PCI-6731 High-Speed I/O card. A deep and vertical micromachining process using swift {sup 35}Cl ions 70 MeV bombarding energy and direct write patterning was performed on LiNbO{sub 3}, a material which exhibits a strong natural anisotropy to conventional etching. The micromachined structures show the feasibility of this method for manufacturing micro-fluidic channels as well.

  6. 4D offline PET-based treatment verification in scanned ion beam therapy: a phantom study

    Science.gov (United States)

    Kurz, Christopher; Bauer, Julia; Unholtz, Daniel; Richter, Daniel; Stützer, Kristin; Bert, Christoph; Parodi, Katia

    2015-08-01

    At the Heidelberg Ion-Beam Therapy Center, patient irradiation with scanned proton and carbon ion beams is verified by offline positron emission tomography (PET) imaging: the {β+} -activity measured within the patient is compared to a prediction calculated on the basis of the treatment planning data in order to identify potential delivery errors. Currently, this monitoring technique is limited to the treatment of static target structures. However, intra-fractional organ motion imposes considerable additional challenges to scanned ion beam radiotherapy. In this work, the feasibility and potential of time-resolved (4D) offline PET-based treatment verification with a commercial full-ring PET/CT (x-ray computed tomography) device are investigated for the first time, based on an experimental campaign with moving phantoms. Motion was monitored during the gated beam delivery as well as the subsequent PET acquisition and was taken into account in the corresponding 4D Monte-Carlo simulations and data evaluation. Under the given experimental conditions, millimeter agreement between the prediction and measurement was found. Dosimetric consequences due to the phantom motion could be reliably identified. The agreement between PET measurement and prediction in the presence of motion was found to be similar as in static reference measurements, thus demonstrating the potential of 4D PET-based treatment verification for future clinical applications.

  7. Image formation, resolution, and height measurement in scanning ion conductance microscopy

    International Nuclear Information System (INIS)

    Scanning ion conductance microscopy (SICM) is an emerging tool for the noncontact investigation of biological samples such as live cells. It uses an ion current through the opening of a tapered nanopipette filled with an electrolyte for topography measurements. Despite its successful application to numerous systems no systematic investigation of the image formation process has yet been performed. Here, we use finite element modeling to investigate how the scanning ion conductance microscope images small particles on a planar surface, providing a fundamental characterization of the imaging process. We find that a small particle appears with a height that is only a fraction of its actual height. This has significant consequences for the quantitative interpretation of SICM images. Furthermore, small and low particles are imaged as rings in certain cases. This can cause small, closely spaced particles to appear with a lateral orientation that is rotated by 90 deg. Considering both real space and spatial frequency space we find that a reasonable and useful definition of lateral resolution of SICM is the smallest distance at which two small particles can clearly be resolved from each other in an image. We find that this resolution is approximately equal to three times the inner radius of the pipette tip opening.

  8. Active spot-scanning test with heavy ions at HIRFL-CSR

    International Nuclear Information System (INIS)

    An active spot beam delivery system for heavy ion therapy has been developed based on the Cooling Storage Ring at HIRFL-CSR, where the pencil carbon-ion beams were scanned within a target volume transversely by a pair of orthogonal (horizontal and vertical) dipole magnets to paint the slices of the target volume and longitudinally by active energy variation of the synchrotron slice by slice. The unique techniques such as dose shaping via active energy variation and magnetic deflection constitute a promising three-dimensional conformal even intensity-modulated radiotherapy with heavy ions at HIRFL-CSR. In this paper, the verification of active energy variation and the calibration of steerable beam deflection are shown, as the basic functionality components of the active spot-scanning system. Additionally, based on the capability of creating homogeneous irradiation fields with steerable pencil beams, a radiobiological experiment like cell survival measurement has been performed aiming at comparison of the radiobiological effects under active and passive beam deliveries. (authors)

  9. Helium Scanning Transmission Ion Microscopy and Electrical Characterization of Glass Nanocapillaries with Reproducible Tip Geometries.

    Science.gov (United States)

    Zweifel, Ludovit P; Shorubalko, Ivan; Lim, Roderick Y H

    2016-02-23

    Nanopores fabricated from glass microcapillaries are used in applications ranging from scanning ion conductance microscopy to single-molecule detection. Still, evaluating the nanocapillary tip by a noninvasive means remains challenging. For instance, electron microscopy characterization techniques can charge, heat, and contaminate the glass surface and typically require conductive coatings that influence the final tip geometry. Per contra, electrical characterization by the means of ion current through the capillary lumen provides only indirect geometrical details of the tips. Here, we show that helium scanning transmission ion microscopy provides a nondestructive and precise determination of glass nanocapillary tip geometries. This enables the reproducible fabrication of axially asymmetric blunt, bullet, and hourglass-shaped tips with opening diameters from 20 to 400 nm by laser-assisted pulling. Accordingly, this allows for an evaluation of how tip shape, pore diameter, and opening angle impact ionic current rectification behavior and the translocation of single molecules. Our analysis shows that current drops and translocation dwell times are dominated by the pore diameter and opening angles regardless of nanocapillary tip shape. PMID:26783633

  10. Robust Neural Network Control of Electrically Driven Robot Manipulator using Backstepping Approach

    Directory of Open Access Journals (Sweden)

    Seyed Ehsan Shafiei

    2010-02-01

    Full Text Available A novel approach to neural network based tracking-control of robot manipulator including actuator dynamics is proposed by using of backstepping method. A simple two-step backstepping is considered for an nlink robotic system, and a feedforward neural controller is designed at second step where structured and unstructured uncertainties in robot dynamics and actuator model are approximated by this neural controller. Bounds of network reconstruction error and other imprecisions are estimated adaptively and for compensating them, a robust control signal is added and modified. Stability analysis is performed by the Lyapunov direct method and performance efficiency of the proposed controller is justified by the simulations.

  11. Measurement of fluence distribution of large area irradiated by scanning high energy ion beam

    International Nuclear Information System (INIS)

    In the JAERI cyclotron, the large area homogeneous irradiation by beam scanning system is used for the experiments on the research of space material, nuclear fusion material and biotechnology. The irradiation is accomplished by deflecting high energy ion beam in the horizontal and vertical directions using a pair of electromagnets. To investigate two-dimensional fluence distribution irradiated by this system, relative fluence distribution was measured with cellulose triacetate film dosimeters. The result showed that the distribution has the inhomogeneity caused by the distorted magnetic wave form of the system and the beam profile. To improve the homogeneity of the distribution, the information about the distribution must be obtained quickly. Therefore, a real time monitoring system of fluence distribution using a parallel plate avalanche counter is developed. The beam scanning system, the measurement of relative fluence distribution using a CTA dosimeter, the real time fluence distribution monitor system with a PPAC and so on are reported. (K.I.)

  12. Development of scanning irradiation in Gunma University Heavy Ion Medical Center

    International Nuclear Information System (INIS)

    Spot scanning irradiation system of carbon ion beam has been developed in Gunma University Heavy Ion Medical Center. During 2013, the beam size and position was stabilized with the use of a pattern-excited steering magnet and optimization of the optic parameters. After these improvement, 3-dimensional spherical field uniform irradiation was carried out based on the measurement of pencil beam profile and depth-dose distribution. The irradiated dose distribution agreed with the calculation within 3%. An experiment of rotating energy absorber has been carried out to suppress the range variation in the extraction period. In order to improve the dose linearity and reproducibility in the low dose region less than 1Gy, the response of I/V converter circuit was improved from 3kHz to 50kHz. After these improvement, the uniform box irradiation was utilized routinely for the animal (mice) experiment from April 2014. (author)

  13. Scanning-probe-microscopy of polyethylene terephthalate surface treatment by argon ion beam

    Science.gov (United States)

    Espinoza-Beltran, Francisco; Sanchez, Isaac C.; España-Sánchez, Beatriz L.; Mota-Morales, Josué D.; Carrillo, Salvador; Enríquez-Flores, C. I.; Poncin-Epaillard, Fabienne; Luna-Barcenas, Gabriel

    2015-11-01

    The effect of argon (Ar+) ion beam treatment on the surface of polyethylene terephthalate (PET) samples was studied by scanning probe microscopy (SPM) and the changes in surface topography were assessed by atomic force microscopy (AFM). Kelvin probe force microscopy (KPFM) sheds light of adhesion force between treated polymer films and a Pt/Cr probe under dry conditions, obtaining the contact potential difference of material. As a result of Ar+ ion bombardment, important surface chemical changes were detected by X-ray photoelectron spectroscopy (XPS) measurements such as chains scission and incorporation of nitrogen species. Ion beam treatment increases the surface roughness from 0.49 ± 0.1 nm to 7.2 ± 0.1 nm and modify the surface potential of PET samples, decreasing the adhesive forces from 12.041 ± 2.1 nN to 5.782 ± 0.06 nN, and producing a slight increase in the electronic work function (Φe) from 5.1 V (untreated) to 5.2 V (treated). Ar+ ion beam treatment allows to potentially changing the surface properties of PET, modifying surface adhesion, improving surface chemical changes, wetting properties and surface potential of polymers.

  14. Scanning photoluminescence technique: application to defect recovery of ion implanted InP

    International Nuclear Information System (INIS)

    The scanning photoluminescence technique at room temperature was applied to characterize the quality of ion-implanted indium phosphide as well as to investigate the defect recovery as a function of the annealing temperature. Doses ranging from 1010 to 1014 ions cm-2 were implanted with either neon or magnesium ions. The intensity of the photoluminescence response was found to be related to the ion dose. Two different substrates were used: an iron-doped semi-insulating one and an undoped one. The results were similar. Nevertheless, the sensitivity was higher for the undoped substrate. After thermal anneals ranging from 200 up to 800oC the average PL intensity was again recorded and was found to increase with the progressive recovery of the defects. After an anneal at 750oC the PL response was comparable to the signal obtained in the case of an annealed reference. The contribution of a doping impurity in a semi-insulating substrate was not clearly evidenced, the PL signal being dominated by the remaining non-radiative centres. (Author)

  15. Accuracy of a 3D online motion compensation system for tumor therapy with scanned ion beams

    International Nuclear Information System (INIS)

    An integrated three-dimensional online motion compensation (3DOMC) system is being developed at GSI to treat tumors in moving organs with scanned ion beams. Target motion is detected by a laser distance sensor, and the motion compensation parameters are calculated in a dedicated module of the treatment control system (TCS). The lateral compensation parameters are sent to the TCS controller of the scanning magnets to adapt the beam laterally. The longitudinal compensation parameters are sent to a range shifter which consists of two sets of PMMA wedges mounted on linear motors. The wedges are placed symmetrically to form a double wedge with a homogeneous thickness in the overlapped area. By moving the wedges apart or together with the linear motors the range of the traversing ion beams can be modulated. The system response time has been optimized to ∼1ms for lateral compensation and to ∼25 ms for 5 mm water equivalent depth compensation. In experiments with a position detector deviations of 0.3 mm RMS were measured for lateral motion compensation by comparing measured and nominal beam positions. For longitudinal compensation an accuracy of 0.2(2) mm was obtained by comparing stationary depth dose profiles to those with motion compensation

  16. Cascade Controller Including Back-stepping for Hydraulic-Mechanical Systems

    DEFF Research Database (Denmark)

    Choux, Martin; Hovland, Geir; Blanke, Mogens

    Development of a cascade controller structure including adaptive backstepping for a nonlinear hydraulic-mechanical system is considered in this paper where a dynamic friction (LuGre) model is included to obtain the necessary accuracy. The paper compares the performance of two variants of an...

  17. Adaptive Backstepping design of an Observer for the Rotor Speed and Field of an Induction Motor

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    is de-veloped. The resulting scheme leads to a nonlinear full order observer for the rotor field. The rotor speed and the stator resis-tance are estimated by adaptive backstepping. Assuming motor parameters known the design achieves stability with guaran-teed region of attraction. The adaptive...

  18. Towards Certifiable Advanced Flight Control Systems, A Sensor Based Backstepping Approach

    NARCIS (Netherlands)

    Falkena, W.; Van Oort, E.R.; Chu, Q.P.

    2011-01-01

    This paper uses singular perturbation theory in order to design a backstepping control system. Earlier applications using singular perturbation theory for control of non-affine systems exist, but here the focus is shifted to uncertain systems. Dealing with uncertainties in this way could be a major

  19. Subsurface Examination of a Foliar Biofilm Using Scanning Electron- and Focused-Ion-Beam Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Patricia K.; Arey, Bruce W.; Mahaffee, Walt F.

    2011-08-01

    The dual beam scanning electron microscope, equipped with both a focused ion- and scanning electron- beam (FIB SEM) is a novel tool for the exploration of the subsurface structure of biological tissues. The FIB can remove a predetermined amount of material from a selected site to allow for subsurface exploration and when coupled with SEM or scanning ion- beam microscopy (SIM) could be suitable to examine the subsurface structure of bacterial biofilms on the leaf surface. The suitability of chemical and cryofixation was examined for use with the FIB SEM to examine bacterial biofilms on leaf surfaces. The biological control agent, Burkholderia pyroccinia FP62, that rapidly colonizes the leaf surface and forms biofilms, was inoculated onto geranium leaves and incubated in a greenhouse for 7 or 14 days. Cryofixation was not suitable for examination of leaf biofilms because it created a frozen layer over the leaf surface that cracked when exposed to the electron beam and the protective cap required for FIB milling could not be accurately deposited. With chemically fixed samples, it was possible to precisely FIB mill a single cross section (5 µm) or sequential cross sections from a single site without any damage to the surrounding surface. Biofilms, 7 days post-inoculation (DPI), were composed of 2 to 5 bacterial cell layers while biofilms 14 DPI ranged from 5 to greater than 30 cell layers. Empty spaces between bacteria cells in the subsurface structure were observed in biofilms 7- and 14-DPI. Sequential cross sections inferred that the empty spaces were often continuous between FP62 cells and could possibly make up a network of channels throughout the biofilm. FIB SEM was a useful tool to observe the subsurface composition of a foliar biofilm.

  20. 4D optimization of scanned ion beam tracking therapy for moving tumors

    Science.gov (United States)

    Eley, John Gordon; Newhauser, Wayne David; Lüchtenborg, Robert; Graeff, Christian; Bert, Christoph

    2014-07-01

    Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existing 3D-optimized beam tracking approach. We tested these approaches computationally using a simple 4D geometrical phantom and a complex anatomic phantom, that is, a 4D computed tomogram of the thorax of a lung cancer patient. We also validated our findings using measurements of carbon-ion beams with a motorized film phantom. Relative to 3D-optimized beam tracking, 4D-optimized beam tracking reduced the maximum predicted dose to avoidance volumes by 53% in the simple phantom and by 13% in the thorax phantom. 4D-optimized beam tracking provided similar target dose homogeneity in the simple phantom (standard deviation of target dose was 0.4% versus 0.3%) and dramatically superior homogeneity in the thorax phantom (D5-D95 was 1.9% versus 38.7%). Measurements demonstrated that delivery of 4D-optimized beam tracking was technically feasible and confirmed a 42% decrease in maximum film exposure in the avoidance region compared with 3D-optimized beam tracking. In conclusion, we found that 4D-optimized beam tracking can reduce the maximum dose to avoidance volumes near a moving target while maintaining target dose coverage, compared with 3D-optimized beam tracking.

  1. Scanning electrochemical microscopy of metallic biomaterials: reaction rate and ion release imaging modes.

    Science.gov (United States)

    Gilbert, J L; Smith, S M; Lautenschlager, E P

    1993-11-01

    The Scanning Electrochemical Microscope (SECM) is a nonoptical scanning microscopic instrument capable of imaging highly localized electrical currents associated with charge transfer reactions on metallic biomaterials surfaces. The SECM operates as an aqueous electrochemical cell under bipotentiostatic control with a microelectrode and sample independently biased as working electrodes. Microelectrode current and position is recorded as it is scanned very near a metallurgically polished planar sample surface. To date, the SECM has imaged metallic biomaterials surfaces in oxygen reaction rate imaging (ORRI) and ion release and deposition imaging (IRDI) modes. In ORRI, sample and microelectrode are biased at sufficiently negative potentials to reduce absorbed oxygen. As the microelectrode scans areas of active oxygen reduction, localized diffusion fields with decreased oxygen solution concentrations are encountered and resultant decrements in microelectrode current are observed. In IRDI mode the sample is positively biased and the microelectrode is negatively biased. The microelectrode detects anodic dissolution products with highest currents being observed over the most active areas. Performance of the SECM has been evaluated on Ni minigrids, gamma-1 Hg-Ag dental amalgam crystals, and sintered beads of Co-Cr-Mo alloy which represent significantly different geometries and corrosion processes to help demonstrate the potential of this instrument. The SECM is a valuable tool for imaging microelectrochemical processes on the surfaces of metallurgically polished metallic biomaterials samples and a wide variety of other surfaces of biological interest where charge transfer reactions occur. The SECM allows selective biasing of metallic biomaterials surfaces and Faradaic reactions can be selectively imaged while the surface is in the active, passive, or transpassive state. PMID:8262998

  2. Scanning electron microscopy of the surfaces of ion implanted SiC

    Energy Technology Data Exchange (ETDEWEB)

    Malherbe, Johan B., E-mail: johan.malherbe@up.ac.za [Department of Physics, University of Pretoria, Pretoria 0002 (South Africa); Berg, N.G. van der; Kuhudzai, R.J.; Hlatshwayo, T.T.; Thabethe, T.T.; Odutemowo, O.S.; Theron, C.C.; Friedland, E. [Department of Physics, University of Pretoria, Pretoria 0002 (South Africa); Botha, A.J. [Laboratory for Microscopy & Microanalysis, University of Pretoria, Pretoria 0002 (South Africa); Wendler, E. [Institut für Festkörperphysik, Friedrich-Schiller-Universität Jena, 07743 Jena (Germany)

    2015-07-01

    This paper gives a brief review of radiation damage caused by particle (ions and neutrons) bombardment in SiC at different temperatures, and its annealing, with an expanded discussion on the effects occurring on the surface. The surface effects were observed using SEM (scanning electron microscopy) with an in-lens detector and EBSD (electron backscatter diffraction). Two substrates were used, viz. single crystalline 6H-SiC wafers and polycrystalline SiC, where the majority of the crystallites were 3C-SiC. The surface modification of the SiC samples by 360 keV ion bombardment was studied at temperatures below (i.e. room temperature), just at (i.e. 350 °C), or above (i.e. 600 °C) the critical temperature for amorphization of SiC. For bombardment at a temperature at about the critical temperature an extra step, viz. post-bombardment annealing, was needed to ascertain the microstructure of bombarded layer. Another aspect investigated was the effect of annealing of samples with an ion bombardment-induced amorphous layer on a 6H-SiC substrate. SEM could detect that this layer started to crystalize at 900 °C. The resulting topography exhibited a dependence on the ion species. EBSD showed that the crystallites forming in the amorphized layer were 3C-SiC and not 6H-SiC as the substrate. The investigations also pointed out the behaviour of the epitaxial regrowth of the amorphous layer from the 6H-SiC interface.

  3. Non-invasive scanning ion-selective electrode technique and its applications to the research of higher plants

    Institute of Scientific and Technical Information of China (English)

    Sun Tong; Xu Yue; Li Peng; Yu Shangguan; Yin Liping

    2007-01-01

    The process of various ions and molecules getting into and out of cells is critical for plant survival. The non-invasive scanning ion-selective electrode technique (SIET) is a non-invasive method to obtain the information of ions/molecules across membranes in plant. This technique can measure the absolute concentration of ions and molecules, and also their fluxes and directions of movement.The samples to be analyzed can be a single cell, a piece of tissue, a whole organ and even an intact seedling. This article reviews the recent progress made in plant physiology by using this technique and discusses its potentials in future studies on plant physiology.

  4. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    International Nuclear Information System (INIS)

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V95) and 107% (V107) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V95 and V107 values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V95 > 87%, SD < 3%) and overdose (mean V107 < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment

  5. Internal composition of atmospheric dust particles from focused ion-beam scanning electron microscopy.

    Science.gov (United States)

    Conny, Joseph M

    2013-08-01

    Use of focused ion-beam scanning electron microscopy (FIB-SEM) to investigate the internal composition of atmospheric particles is demonstrated for assessing particle optical properties. In the FIB-SEM instrument equipped with an X-ray detector, a gallium-ion beam mills the particle, while the electron beam images the slice faces and energy-dispersive X-ray spectroscopy provides element maps of the particle. Differences in assessments of optical behavior based on FIB-SEM and conventional SEM were shown for five selected urban dust particles. The benefit of FIB-SEM for accurately determining the depth and size of optically important phases within particles was shown. FIB-SEM revealed that iron oxide grains left undetected by conventional SEM could potentially shift the single-scattering albedo of the particle from negative to positive radiative forcing. Analysis of a coke-like particle showed that 73% of the light-scattering inclusion went undetected with conventional SEM, causing the bulk absorption coefficient to vary by as much as 25%. Optical property calculations for particles as volume-equivalent spheres and as spheroids that approximated actual particle shapes revealed that the largest effect between conventional SEM and FIB-SEM analyses was on backscattering efficiency, in some cases varying several-fold. PMID:23763344

  6. Uniform irradiation of high-energy intense ion beams to large area by two-dimensional beam scanning

    International Nuclear Information System (INIS)

    JAERI AVF cyclotron is equipped with ion beam scanners for large area irradiation. The cyclotron beam is two-dimensionally scanned by using a pair of laminated electromagnets. Cellulose triacetate (CTA) film dosimeter has been successfully applied as an integral method to measurement of the two-dimensional relative fluence distributions of the scanned ion beams, proton, He, C, Ar and Kr. The measured result showed that the fluence was not uniform within the scanned area. We have developed a beam scanning simulator to evaluate fluence distribution by calculation, and the simulation result was compared with the measured distribution. The un-uniformity was found to result from the distortion of the current wave form of the scanner. On the basis of this result, the power supply of the scanner was improved. A good uniformity of fluence distribution was available within ±4%. (author)

  7. Scanning tunneling microscopy study of pinning-induced vortex lattice distortion in ion-irradiated NbSe2

    International Nuclear Information System (INIS)

    We observe vortex pinning in 2.2 GeV Au-ion irradiated NbSe2 by scanning tunneling microscopy (STM) at 3 K. The ion irradiation generates columnar defects which act as pinning sites. At various external magnetic fields the vortex arrangement is clearly resolved but shows strong distortion. The location of individual defects is extracted from STM data and compared to the vortex arrangement. (orig.)

  8. Integration and evaluation of automated Monte Carlo simulations in the clinical practice of scanned proton and carbon ion beam therapy

    International Nuclear Information System (INIS)

    Monte Carlo (MC) simulations of beam interaction and transport in matter are increasingly considered as essential tools to support several aspects of radiation therapy. Despite the vast application of MC to photon therapy and scattered proton therapy, clinical experience in scanned ion beam therapy is still scarce. This is especially the case for ions heavier than protons, which pose additional issues like nuclear fragmentation and varying biological effectiveness. In this work, we present the evaluation of a dedicated framework which has been developed at the Heidelberg Ion Beam Therapy Center to provide automated FLUKA MC simulations of clinical patient treatments with scanned proton and carbon ion beams. Investigations on the number of transported primaries and the dimension of the geometry and scoring grids have been performed for a representative class of patient cases in order to provide recommendations on the simulation settings, showing that recommendations derived from the experience in proton therapy cannot be directly translated to the case of carbon ion beams. The MC results with the optimized settings have been compared to the calculations of the analytical treatment planning system (TPS), showing that regardless of the consistency of the two systems (in terms of beam model in water and range calculation in different materials) relevant differences can be found in dosimetric quantities and range, especially in the case of heterogeneous and deep seated treatment sites depending on the ion beam species and energies, homogeneity of the traversed tissue and size of the treated volume. The analysis of typical TPS speed-up approximations highlighted effects which deserve accurate treatment, in contrast to adequate beam model simplifications for scanned ion beam therapy. In terms of biological dose calculations, the investigation of the mixed field components in realistic anatomical situations confirmed the findings of previous groups so far reported only in

  9. Systematic evaluation of four-dimensional hybrid depth scanning for carbon-ion lung therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Shinichiro; Furukawa, Takuji; Inaniwa, Taku; Zenklusen, Silvan; Nakao, Minoru; Shirai, Toshiyuki; Noda, Koji [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Inage-ku, Chiba 263-8555 (Japan)

    2013-03-15

    Purpose: Irradiation of a moving target with a scanning beam requires a comprehensive understanding of organ motion as well as a robust dose error mitigation technique. The authors studied the effects of intrafractional respiratory motion for carbon-ion pencil beam scanning with phase-controlled rescanning on dose distributions for lung tumors. To address density variations, they used 4DCT data. Methods: Dose distributions for various rescanning methods, such as simple layer rescanning (LR), volumetric rescanning, and phase-controlled rescanning (PCR), were calculated for a lung phantom and a lung patient studies. To ensure realism, they set the scanning parameters such as scanning velocity and energy variation time to be similar to those used at our institution. Evaluation metrics were determined with regard to clinical relevance, and consisted of (i) phase-controlled rescanning, (ii) sweep direction, (iii) target motion (direction and amplitude), (iv) respiratory cycle, and (v) prescribed dose. Spot weight maps were calculated by using a beam field-specific target volume, which takes account of range variations for respective respiratory phases. To emphasize the impact of intrafractional motion on the dose distribution, respiratory gating was not used. The accumulated dose was calculated by applying a B-spline-based deformable image registration, and the results for phase-controlled layered rescanning (PCR{sub L}) and phase-controlled volumetric rescanning (PCR{sub V}) were compared. Results: For the phantom study, simple LR was unable to improve the dose distributions for an increased number of rescannings. The phase-controlled technique without rescanning (1 Multiplication-Sign PCR{sub L} and 1 Multiplication-Sign PCR{sub V}) degraded dose conformity significantly due to a reduced scan velocity. In contrast, 4 Multiplication-Sign PCR{sub L} or more significantly and consistently improved dose distribution. PCR{sub V} showed interference effects, but in general

  10. Command Filtered Adaptive Fuzzy Neural Network Backstepping Control for Marine Power System

    Directory of Open Access Journals (Sweden)

    Xin Zhang

    2014-01-01

    Full Text Available In order to retrain chaotic oscillation of marine power system which is excited by periodic electromagnetism perturbation, a novel command-filtered adaptive fuzzy neural network backstepping control method is designed. First, the mathematical model of marine power system is established based on the two parallel nonlinear model. Then, main results of command-filtered adaptive fuzzy neural network backstepping control law are given. And the Lyapunov stability theory is applied to prove that the system can remain closed-loop asymptotically stable with this controller. Finally, simulation results indicate that the designed controller can suppress chaotic oscillation with fast convergence speed that makes the system return to the equilibrium point quickly; meanwhile, the parameter which induces chaotic oscillation can also be discriminated.

  11. Robust Backstepping Control Based on a Lyapunov Redesign for Skid-Steered Wheeled Mobile Robots

    Directory of Open Access Journals (Sweden)

    Eun-Ju Hwang

    2013-01-01

    Full Text Available This paper represents a robust backstepping tracking control based on a Lyapunov redesign for Skid‐Steered Wheeled Mobile Robots (WMRs. We present kinematic and dynamic models that explicitly relate the perturbations to the skidding in order to improve the tracking performance during real running. A robust controller is synthesized in the backstepping approach and the Lyapunov redesign technique, which forces the error dynamics to stabilize to the reference trajectories. We design an additional feedback control ‐ a Lyapunov redesign ‐ such that the overall control stabilizes the actual system in the presence of uncertainty and perturbation with the knowledge of the Lyapunov function. Simulation results are provided to validate and analyse the performance and stability of the proposed controller.

  12. Aircraft-on-ground path following control by dynamical adaptive backstepping

    Institute of Scientific and Technical Information of China (English)

    Chen Bihua; Jiao Zongxia; Shuzhi Sam Ge

    2013-01-01

    The necessity of improving the air traffic and reducing the aviation emissions drives to investigate automatic steering for aircraft to effectively roll on the ground.This paper addresses the path following control problem of aircraft-on-ground and focuses on the task that the aircraft is required to follow the desired path on the runway by nose wheel automatic steering.The proposed approach is based on dynamical adaptive backstepping so that the system model does not have to be transformed into a canonical triangular form which is necessary in conventional backstepping design.This adaptive controller performs well despite the lack of information on the aerodynamic load and the tire cornering stiffness parameters.Simulation results clearly demonstrate the advantages and effectiveness of the proposed approach.

  13. Path Following of an Underactuated AUV Based on Fuzzy Backstepping Sliding Mode Control

    Directory of Open Access Journals (Sweden)

    Xiao Liang

    2016-06-01

    Full Text Available This paper addresses the path following problem of an underactuated autonomous underwater vehicle (AUV with the aim of dealing with parameter uncertainties and current disturbances. An adaptive robust control system was proposed by employing fuzzy logic, backstepping and sliding mode control theory. Fuzzy logic theory is adopted to approximate unknown system function, and the controller was designed by combining sliding mode control with backstepping thought. Firstly, the longitudinal speed was controlled, then the yaw angle was made as input of path following error to design the calm function and the change rate of path parameters. The controller stability was proved by Lyapunov stable theory. Simulation and outfield tests were conducted and the results showed that the controller is of excellent adaptability and robustness in the presence of parameter uncertainties and external disturbances. It is also shown to be able to avoid the chattering of AUV actuators.

  14. Design of a nonlinear backstepping control strategy of grid interconnected wind power system based PMSG

    Science.gov (United States)

    Errami, Y.; Obbadi, A.; Sahnoun, S.; Benhmida, M.; Ouassaid, M.; Maaroufi, M.

    2016-07-01

    This paper presents nonlinear backstepping control for Wind Power Generation System (WPGS) based Permanent Magnet Synchronous Generator (PMSG) and connected to utility grid. The block diagram of the WPGS with PMSG and the grid side back-to-back converter is established with the dq frame of axes. This control scheme emphasises the regulation of the dc-link voltage and the control of the power factor at changing wind speed. Besides, in the proposed control strategy of WPGS, Maximum Power Point Tracking (MPPT) technique and pitch control are provided. The stability of the regulators is assured by employing Lyapunov analysis. The proposed control strategy for the system has been validated by MATLAB simulations under varying wind velocity and the grid fault condition. In addition, a comparison of simulation results based on the proposed Backstepping strategy and conventional Vector Control is provided.

  15. Station-keeping control for a stratospheric airship platform via fuzzy adaptive backstepping approach

    Science.gov (United States)

    Yang, Yueneng; Wu, Jie; Zheng, Wei

    2013-04-01

    This paper presents a novel approach for station-keeping control of a stratospheric airship platform in the presence of parametric uncertainty and external disturbance. First, conceptual design of the stratospheric airship platform is introduced, including the target mission, configuration, energy sources, propeller and payload. Second, the dynamics model of the airship platform is presented, and the mathematical model of its horizontal motion is derived. Third, a fuzzy adaptive backstepping control approach is proposed to develop the station-keeping control system for the simplified horizontal motion. The backstepping controller is designed assuming that the airship model is accurately known, and a fuzzy adaptive algorithm is used to approximate the uncertainty of the airship model. The stability of the closed-loop control system is proven via the Lyapunov theorem. Finally, simulation results illustrate the effectiveness and robustness of the proposed control approach.

  16. Sampled-Data Backstepping Control of a Quadrotor Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    Abdul Jabbar

    2014-12-01

    Full Text Available Sampled-data backstepping control of a quadrotor UAV is presented in this paper. The discrete time controllers have been designed on the basis of a continuous time system model and an approximate discrete time equivalent system model (Euler Approximate model obtained using the Euler method. The performance of the controllers obtained using the two sampled-data approaches has been compared in the presence of wing gusts and modeling uncertainties. Simulations have revealed that the backstepping controller designed on the basis of an approximate discrete time model has better performance in the presence of wind gusts and modeling uncertainties. In addition, the closed loop system has a larger region of attraction.

  17. Novel backstepping design for blended aero and reaction-jet missile autopilot

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The advanced missile uses blended control of aero-fin and reaction-jet to improve missile maneuverability.The blended control design,which is multi-inputs and multi-outputs (MIMO),severe nonlinear,and model uncertain,is much more complex than conventional aero-fin control.A novel nonlinear backstepping control approach is proposed to design the blended autopilot.Missile model is reformed to a new one by state reconstruction technique so that it is easy to be handled by the backetepping method.Then a Lyapunov function is chosen to avoid oscillation caused in normal backstepping way when control parameters are mismatched.In distribution of both inputs,optimal energy logic is proposed.In addition,a fuzzy cerebellar model articulation controller (FCMAC)neural network is used to guarantee controller robustness to uncertainties.Finally,simulation results demonstrate the efficiency and advantages of the proposed method.

  18. Adaptive Backstepping controller design and implementation for a matrix-converter-based IM drive system

    Directory of Open Access Journals (Sweden)

    R.R. Joshi

    2007-06-01

    Full Text Available A systematic controller design and implementation for a matrix-converter-based induction motor drive system is proposed. A nonlinear adaptive backstepping controller is proposed to improve the speed and position responses of the induction motor system. By using the proposed adaptive backstepping controller, the system can track a time-varying speed command and a time-varying position command well. Moreover, the system has a good load disturbance rejection capability. The realization of the controller is very simple. All of the control loops, including the current loop, speed loop and position loop, are implemented by a digital signal processor. Several experimental results are given to validate the theoretical analysis.

  19. Robust Backstepping Control for Cold Rolling Main Drive System with Nonlinear Uncertainties

    OpenAIRE

    Xu Yang; Kai-xiang Peng; Chao-nan Tong

    2013-01-01

    The nonlinear model of main drive system in cold rolling process, which considers the influence with parameter uncertainties such as clearance and variable friction coefficient, as well as external disturbance by roll eccentricity and variation of strip material quality, is built. By transformation, the lower triangular structure form of main drive system is obtained. The backstepping algorithm based on signal compensation is proposed to design a linear time-invariant (LTI) robust controller,...

  20. DESIGN AND OPTIMIZATION OF BACKSTEPPING CONTROLLER FOR AN UNDERACTUATED AUTONOMOUS QUADROTOR UNMANNED AERIAL VEHICLE

    OpenAIRE

    Mohd Basri, Mohd Ariffanan; Danapalasingam, Kumeresan A.; Husain, Abdul Rashid

    2014-01-01

    The development of a high performance controller for a quadrotor unmanned aerial vehicle (UAV) is a challenging issue since a quadrotor is an underactuated and a highly unstable nonlinear system. In this paper, the contribution is focused on the design and optimization of a controller for an autonomous quadrotor UAV. Firstly, the dynamic model of the aerial vehicle is mathematically formulated. Then, an optimal backstepping controller (OBC) is proposed. Conventionally, control parameters of a...

  1. Backstepping design of missile guidance and control based on adaptive fuzzy sliding mode control

    OpenAIRE

    Ran Maopeng; Wang Qing; Hou Delong; Dong Chaoyang

    2014-01-01

    This paper presents an integrated missile guidance and control law based on adaptive fuzzy sliding mode control. The integrated model is formulated as a block-strict-feedback nonlinear system, in which modeling errors, unmodeled nonlinearities, target maneuvers, etc. are viewed as unknown uncertainties. The adaptive nonlinear control law is designed based on backstepping and sliding mode control techniques. An adaptive fuzzy system is adopted to approximate the coupling nonlinear functions of...

  2. Robust Adaptive Control for a Class of Nonlinear Systems Using the Backstepping Method

    OpenAIRE

    Farouk Zouari; Kamel Ben Saad; Mohamed Benrejeb

    2013-01-01

    This paper develops a robust adaptive control for a class of nonlinear systems using the backstepping method. The proposed robust adaptive control is a recursive method based on the Lyapunov synthesis approach. It ensures that, for any initial conditions, all the signals of the closed‐loop system are regularly bounded and the tracking errors converge to zero. The results are illustrated with simulation examples.

  3. Adaptive Backstepping Sliding-Mode Control of the Electronic Throttle System in Modern Automobiles

    Directory of Open Access Journals (Sweden)

    Rui Bai

    2014-01-01

    Full Text Available In modern automobiles, electronic throttle is a DC-motor-driven valve that regulates air inflow into the vehicle’s combustion system. The electronic throttle is increasingly being used in order to improve the vehicle drivability, fuel economy, and emissions. Electronic throttle system has the nonlinear dynamical characteristics with the unknown disturbance and parameters. At first, the dynamical nonlinear model of the electronic throttle is built in this paper. Based on the model and using the backstepping design technique, a new adaptive backstepping sliding-mode controller of the electronic throttle is developed. During the backstepping design process, parameter adaptive law is designed to estimate the unknown parameter, and sliding-mode control term is applied to compensate the unknown disturbance. The proposed controller can make the actual angle of the electronic throttle track its set point with the satisfactory performance. Finally, a computer simulation is performed, and simulation results verify that the proposed control method can achieve favorable tracking performance.

  4. Robust intelligent backstepping tracking control for uncertain non-linear chaotic systems using H∞ control technique

    International Nuclear Information System (INIS)

    The cerebellar model articulation controller (CMAC) is a non-linear adaptive system with built-in simple computation, good generalization capability and fast learning property. In this paper, a robust intelligent backstepping tracking control (RIBTC) system combined with adaptive CMAC and H∞ control technique is proposed for a class of chaotic systems with unknown system dynamics and external disturbance. In the proposed control system, an adaptive backstepping cerebellar model articulation controller (ABCMAC) is used to mimic an ideal backstepping control (IBC), and a robust H∞ controller is designed to attenuate the effect of the residual approximation errors and external disturbances with desired attenuation level. Moreover, the all adaptation laws of the RIBTC system are derived based on the Lyapunov stability analysis, the Taylor linearization technique and H∞ control theory, so that the stability of the closed-loop system and H∞ tracking performance can be guaranteed. Finally, three application examples, including a Duffing-Holmes chaotic system, a Genesio chaotic system and a Sprott circuit system, are used to demonstrate the effectiveness and performance of proposed robust control technique.

  5. The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study

    CERN Document Server

    Parodi, K; Kraemer, M; Sommerer, F; Naumann, J; Mairani, A; Brons, S

    2010-01-01

    Scanned ion beam delivery promises superior flexibility and accuracy for highly conformal tumour therapy in comparison to the usage of passive beam shaping systems. The attainable precision demands correct overlapping of the pencil-like beams which build up the entire dose distribution in the treatment field. In particular, improper dose application due to deviations of the lateral beam profiles from the nominal planning conditions must be prevented via appropriate beam monitoring in the beamline, prior to the entrance in the patient. To assess the necessary tolerance thresholds of the beam monitoring system at the Heidelberg Ion Beam Therapy Center, Germany, this study has investigated several worst-case scenarios for a sensitive treatment plan, namely scanned proton and carbon ion delivery to a small target volume at a shallow depth. Deviations from the nominal lateral beam profiles were simulated, which may occur because of misaligned elements or changes of the beam optic in the beamline. Data have been an...

  6. Scanning transmission ion microscopy computed tomography (STIM-CT) for inertial confinement fusion (ICF) targets

    International Nuclear Information System (INIS)

    Highlights: ► ICF target quality requires surface finishes on the order of submicron-scale. ► In STIM inner and outer wall profile can be mapped. ► In STIM the thickness and nonconcentricity of shell-wall in ICF targets can be measured. ► STIM-CT is a powerful method for obtaining three-dimensional density maps within ICF targets. ► STIM-CT can obtain internal structure with identifying non-uniformities in the ICF targets. -- Abstract: ICF target quality control in the laser fusion program is vital to ensure that the energy deposition from the lasers results in uniform compression and minimization of Rayleigh–Taylor instabilities, which requires surface finishes on the order of submicron-scale. During target fabrication process the surface finish and the dimensions of the hohlraum need be well controlled. Density variations and nonspherical or nonconcentric shells might be produced. Scanning transmission ion microscopy computed tomography (STIM-CT) is able to reconstruct the three-dimensional quantitative structure of ICF targets a few tens of micrometers in size. Compared to other types of probe techniques, the main advantage of STIM-CT is that quantitative information about mass density and sphericity can be obtained directly and non-destructively, utilizing specific reconstruction codes. We present a case of ICF target (composed of polyvinyl alcohol) characterization by STIM-CT in order to demonstrate the STIM-CT potential impact in assessing target fabrication processes

  7. Active raster scanning with carbon ions. Reirradiation in patients with recurrent skull base chordomas and chondrosarcomas

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, Matthias; Welzel, Thomas; Oelmann, Jan; Habl, Gregor; Hauswald, Henrik; Jensen, Alexandra; Debus, Juergen; Herfarth, Klaus [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Ellerbrock, Malte [Heidelberg Ion Therapy Center (HIT), Heidelberg (Germany)

    2014-07-15

    To evaluate the safety and efficacy of reirradiation with carbon ions in patients with relapse of skull base chordoma and chondrosarcoma. Reirradiation with carbon ions was performed on 25 patients with locally recurrent skull base chordoma (n = 20) or chondrosarcoma (n = 5). The median time between the last radiation exposure and the reirradiation with carbon ions was 7 years. In the past, 23 patients had been irradiated once, two patients twice. Reirradiation was delivered using the active raster scanning method. The total median dose was 51.0 GyE carbon ions in a weekly regimen of five to six fractions of 3 GyE. Local progression-free survival (LPFS) was evaluated using the Kaplan-Meier method; toxicity was evaluated using the NCI Common Terminology Criteria for Adverse Events (CTCAE v.4.03). The treatment could be finished in all patients without interruption. In 80 % of patients, symptom control was achieved after therapy. The 2-year-LPFS probability was 79.3 %. A PTV volume of < 100 ml or a total dose of > 51 GyE was associated with a superior local control rate. The therapy was associated with low acute toxicity. One patient developed grade 2 mucositis during therapy. Furthermore, 12 % of patients had tympanic effusion with mild hypacusis (grade 2), while 20 % developed an asymptomatic temporal lobe reaction after treatment (grade 1). Only one patient showed a grade 3 osteoradionecrosis. Reirradiation with carbon ions is a safe and effective method in patients with relapsed chordoma and chondrosarcoma of the skull base. (orig.) [German] Evaluierung der Sicherheit und Wirksamkeit einer Re-Bestrahlung mittels Kohlenstoffionen bei Patienten mit Lokalrezidiv eines Chordoms und Chondrosarkoms der Schaedelbasis. Bei 25 Patienten mit einem Lokalrezidiv eines Chordoms (n = 20) oder Chondrosarkoms (n = 5) der Schaedelbasis erfolgte eine Re-Bestrahlung mittels Kohlenstoffionen. Die mediane Zeit zwischen letzter Bestrahlung und Re-Bestrahlung mit Kohlenstoffionen

  8. Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy

    International Nuclear Information System (INIS)

    In order to better understand biochemical processes inside an individual cell, it is important to measure the molecular composition at the submicron level. One of the promising mass spectrometry imaging techniques that may be used to accomplish this is Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), using MeV energy heavy ions for excitation. MeV ions have the ability to desorb large intact molecules with a yield that is several orders of magnitude higher than conventional SIMS using keV ions. In order to increase the spatial resolution of the MeV TOF-SIMS system, we propose an independent TOF trigger using a STIM (scanning transmission ion microscopy) detector that is placed just behind the thin transmission target. This arrangement is suitable for biological samples in which the STIM detector simultaneously measures the mass distribution in scanned samples. The capability of the MeV TOF-SIMS setup was demonstrated by imaging the chemical composition of CaCo-2 cells

  9. Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Siketić, Zdravko; Bogdanović Radović, Ivančica; Jakšić, Milko; Popović Hadžija, Marijana; Hadžija, Mirko [Ruđer Bošković Institute, Bijenička cesta 54, 10000 Zagreb (Croatia)

    2015-08-31

    In order to better understand biochemical processes inside an individual cell, it is important to measure the molecular composition at the submicron level. One of the promising mass spectrometry imaging techniques that may be used to accomplish this is Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), using MeV energy heavy ions for excitation. MeV ions have the ability to desorb large intact molecules with a yield that is several orders of magnitude higher than conventional SIMS using keV ions. In order to increase the spatial resolution of the MeV TOF-SIMS system, we propose an independent TOF trigger using a STIM (scanning transmission ion microscopy) detector that is placed just behind the thin transmission target. This arrangement is suitable for biological samples in which the STIM detector simultaneously measures the mass distribution in scanned samples. The capability of the MeV TOF-SIMS setup was demonstrated by imaging the chemical composition of CaCo-2 cells.

  10. Application of radiochromic film for quality assurance in the heavy-ion beam scanning irradiation system at HIMAC

    International Nuclear Information System (INIS)

    For the quality assurance (QA) of therapeutic scanned carbon-ion beams, QA tool having high spatial resolution is required. The radiochromic film (such as Gafchromic EBT2 film model) is a very useful tool because of its high spatial resolution, self-development, and near tissue equivalence. However, for a complex field in carbon-ion therapy, it is difficult to unambiguously determine the dose from the measured net optical density (OD). As a first approach, we investigated the response of EBT2 to carbon-ion beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC) in Japan. Based on the measured results, we performed QA measurements independently of dose. We verified the QA measurements by EBT2 by comparing the ionization chamber and the fluorescent screen. The results obtained with EBT2 were in good agreement with those obtained with the other detector. In addition, to test the use in a complex field, we verified the OD distributions for moving and static target by means of a gamma index analysis. As a result, we confirmed that EBT2 could be used as a part of QA procedures for therapeutic scanned carbon-ion beams

  11. Research and design of scanning power supply for deep tumor therapy facility with heavy ions accelerator in Lanzhou

    International Nuclear Information System (INIS)

    This paper describes the technique targets and operation principle of the scanning power supply for the deep tumor therapy facility with heavy ions in Cooler-Storage-Ring of the Heavy Ion Research Facility in Lanzhou (HIRFL-CSR). To ensure the specified accuracy of the current, the hysteresis loop control strategy was adopted, and tracking error was constrained in the specified tolerance. One prototype was designed and installed. And the simulation results and test results were listed in the paper. The results show that all the targets can meet the design requirements, and that the circuit configuration and hysteresis loop control strategy selected are practicable. (authors)

  12. Simultaneous Screening of Glutathione and Cyanide Adducts Using Precursor Ion and Neutral Loss Scans-Dependent Product Ion Spectral Acquisition and Data Mining Tools

    Science.gov (United States)

    Jian, Wenying; Liu, Hua-Fen; Zhao, Weiping; Jones, Elliott; Zhu, Mingshe

    2012-05-01

    Drugs can be metabolically activated to soft and hard electrophiles, which are readily trapped by glutathione (GSH) and cyanide (CN), respectively. These adducts are often detected and structurally characterized using separate tandem mass spectrometry methods. We describe a new method for simultaneous screening of GSH and CN adducts using precursor ion (PI) and neutral loss (NL) scans-dependent product ion spectral acquisition and data mining tools on an triple quadrupole linear ion trap mass spectrometry. GSH, potassium cyanide, and their stable isotope labeled analogues were incubated with liver microsomes and a test compound. Negative PI scan of m/z 272 for detection of GSH adducts and positive NL scans of 27 and 29 Da for detection of CN adducts were conducted as survey scans to trigger acquisition of enhanced resolution (ER) spectrum and subsequent enhanced product ion (EPI) spectrum. Post-acquisition data mining of EPI data set using NL filters of 129 and 27 Da was then performed to reveal the GSH adducts and CN adducts, respectively. Isotope patterns and EPI spectra of the detected adducts were utilized for identification of their molecular weights and structures. The effectiveness of this method was evaluated by analyzing reactive metabolites of nefazodone formed from rat liver microsomes. In addition to known GSH- and CN-trapped reactive metabolites, several new CN adducts of nefazodone were identified. The results suggested that current approach is highly effective in the analysis of both soft and hard reactive metabolites and can be used as a high-throughput method in drug discovery.

  13. Motion compensation with a scanned ion beam: a technical feasibility study

    OpenAIRE

    Kraft Gerhard; Haberer Thomas; Bert Christoph; Grözinger Sven; Rietzel Eike

    2008-01-01

    Abstract Background Intrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target motion by tracking with the treatment beam. Methods Lateral motion components were compensated directly with the beam scanning system by adapting nominal beam positions according to the target motion. Longitudinal motion compensation to mitigate motion induced range changes was performed with a dedicated w...

  14. Design of robust fuzzy controller for ship course-tracking based on RBF network and backstepping approach

    Institute of Scientific and Technical Information of China (English)

    ZHANG Song-tao; REN Guang

    2006-01-01

    This study presents an adaptive fuzzy neural network (FNN) control system for the ship steering autopilot. For the Norrbin ship steering mathematical model with the nonlinear and uncertain dynamic characteristics, an adaptive FNN control system is designed to achieve high-precision track control via the backstepping approach. In the adaptive FNN control system, a FNN backstepping controller is a principal controller which includes a FNN estimator used to estimate the uncertainties, and a robust controller is designed to compensate the shortcoming of the FNN backstepping controller. All adaptive learning algorithms in the adaptive FNN control system are derived from the sense of Lyapunov stability analysis, so that system-tracking stability can be guaranteed in the closed-loop system. The effectiveness of the proposed adaptive FNN control system is verified by simulation results.

  15. Full adaptive backstepping design of a Speed Sensorless Field Oriented Controller for an Induction Motor

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Vadstrup, P.; Børsting, H.

    2001-01-01

    princip. A full proof for convergence of states is presented together with a stability proof for the parameter estimates. When the system is persistently excited simulations and experiments show convergence of the parameters. The observer is used in a Rotor Field Oriented Control strategy and verified by......It is well known that modern induction motor control rely on a good dynamic model of the motor. Full state variable information together with exact parameter knowledge is needed. The aim of this work is to fulfill these needs by use of a novel nonlinear observer structure based on the backstepping...

  16. Backstepping-based lag synchronization of a complex permanent magnet synchronous motor system

    International Nuclear Information System (INIS)

    Through introducing the concept of complex current and resetting cross-coupling term, this paper proposes a novel complex permanent magnet synchronous motor system and analyzes its properties. Based on a complex permanent magnet synchronous motor system, we design controllers and achieve lag synchronizations both in real part and imaginary part with backstepping method. In our study, we take complex current, time delay, and structure of complex system into consideration. Numerical simulation results demonstrate the validity of controllers. (interdisciplinary physics and related areas of science and technology)

  17. Effects of 10-MeV ion irradiation on Au/Ta studied with scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Adhesion of a 10-nm Au film on a Ta substrate is enhanced with 10-MeV Si ion irradiation at room temperature. The modifications of surface topography on a Au film are investigated by Scanning Tunneling Microscopy (STM). Surface craters and defects have been observed in this metal/metal system. It is shown that the higher the dose of ion irradiation, the higher the density and the bigger the size of the craters. The craters which are several nanometers in diameter extend from the surface into the interfacial region. A threshold dose at which the Au film can pass the Scotch tape test is determined, and the mechanism of the adhesion enhancement by ion bombardment is discussed

  18. Fine structures and ion images on fresh frozen dried ultrathin sections by transmission electron and scanning ion microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Takaya, K.; Okabe, M.; Sawataishi, M.; Takashima, H.; Yoshida, T

    2003-01-15

    Ion microscopy (IM) of air-dried or freeze-dried cryostat and semi-thin cryosections has provided ion images of elements and organic substances in wide areas of the tissue. For reproducible ion images by a shorter time of exposure to the primary ion beam, fresh frozen dried ultrathin sections were prepared by freezing the tissue in propane chilled with liquid nitrogen, cryocut at 60 nm, mounted on grids and silicon wafer pieces, and freeze-dried. Rat Cowper gland and sciatic nerve, bone marrow of the rat administered of lithium carbonate, tree frog and African toad spleen and buffy coat of atopic dermatitis patients were examined. Fine structures and ion images of the corresponding areas in the same or neighboring sections were observed by transmission electron microscopy (TEM) followed by sector type and time-of-flight type IM. Cells in the buffy coat contained larger amounts of potassium and magnesium while plasma had larger amounts of sodium and calcium. However, in the tissues, lithium, sodium, magnesium, calcium and potassium were distributed in the cell and calcium showed a granular appearance. A granular cell of the tree frog spleen contained sodium and potassium over the cell and magnesium and calcium were confined to granules.

  19. Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope

    Energy Technology Data Exchange (ETDEWEB)

    Akhmadaliev, C.

    2004-12-01

    The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 {mu}s, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1{sup +} to 4{sup +}. The acoustic amplitude dependence on the ion beam parameters like the ion mass and energy, the ion charge state, the beam spot size and the pulse duration were of interest. This work deals with ultrasound transmitted in a solid, i.e. bulk waves, because of their importance for acoustic transmission microscopy and nondestructive inspection of internal structure of a sample. The second part of this work was carried out using the IMSA-100 FIB system operating in an energy range from 30 to 70 keV. The scanning ion acoustic microscope based on this FIB system was developed and tested. (orig.)

  20. Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope

    International Nuclear Information System (INIS)

    The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 μs, applying ions with different masses, e.g. oxygen, silicon and gold, in charge states from 1+ to 4+. The acoustic amplitude dependence on the ion beam parameters like the ion mass and energy, the ion charge state, the beam spot size and the pulse duration were of interest. This work deals with ultrasound transmitted in a solid, i.e. bulk waves, because of their importance for acoustic transmission microscopy and nondestructive inspection of internal structure of a sample. The second part of this work was carried out using the IMSA-100 FIB system operating in an energy range from 30 to 70 keV. The scanning ion acoustic microscope based on this FIB system was developed and tested. (orig.)

  1. Development and characterization of a 2D scintillation detector for quality assurance in scanned carbon ion beams

    Science.gov (United States)

    Tamborini, A.; Raffaele, L.; Mirandola, A.; Molinelli, S.; Viviani, C.; Spampinato, S.; Ciocca, M.

    2016-04-01

    At the Centro Nazionale di Adroterapia Oncologica (CNAO Foundation), a two-dimensional high resolution scintillating dosimetry system has been developed and tested for daily Quality Assurance measurements (QA) in carbon ion radiotherapy with active scanning technique, for both single pencil beams and scanned fields produced by a synchrotron accelerator. The detector consists of a thin plane organic scintillator (25×25 cm2, 2 mm thick) coupled with a high spatial resolution CCD camera (0.25 mm) in a light-tight box. A dedicated Labview software was developed for image acquisition triggered with the beam extraction, data post-processing and analysis. The scintillator system was preliminary characterized in terms of short-term reproducibility (found to be within±0.5%), linearity with the number of particles (linear fit χ2 = 0.996) and dependence on particle flux (measured to be < 1.5 %). The detector was then tested for single beam spot measurements (Full Width at Half Maximum and position) and for 6×6 cm2 reference scanned field (determination of homogeneity) for carbon ions with energy from 115 MeV/u up to 400 MeV/u. No major differences in the investigated beam parameters measured with scintillator system and the radiochromic EBT3 reference films were observed. The system allows therefore real-time monitoring of the carbon ion beam relevant parameters, with a significant daily time saving with respect to films currently used. The results of this study show the suitability of the scintillation detector for daily QA in a carbon ion facility with an active beam delivery system.

  2. Motion compensation with a scanned ion beam: a technical feasibility study

    International Nuclear Information System (INIS)

    Intrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target motion by tracking with the treatment beam. Lateral motion components were compensated directly with the beam scanning system by adapting nominal beam positions according to the target motion. Longitudinal motion compensation to mitigate motion induced range changes was performed with a dedicated wedge system that adjusts effective particle energies at isocenter. Lateral compensation performance was better than 1% for a homogeneous dose distribution when comparing irradiations of a stationary radiographic film and a moving film using motion compensation. The accuracy of longitudinal range compensation was well below 1 mm. Motion compensation with scanned particle beams is technically feasible with high precision

  3. Optimized treatment parameters to account for interfractional variability in scanned ion beam therapy of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Brevet, Romain

    2015-02-04

    Scanned ion beam therapy of lung tumors is severely limited in its clinical applicability by intrafractional organ motion, interference effects between beam and tumor motion (interplay) as well as interfractional anatomic changes. To compensate for dose deterioration by intrafractional motion, motion mitigation techniques, such as gating have been developed. The latter confines the irradiation to a predetermined breathing state, usually the stable end-exhale phase. However, optimization of the treatment parameters is needed to further improve target dose coverage and normal tissue sparing. The aim of the study presented in this dissertation was to determine treatment planning parameters that permit to recover good target coverage and homogeneity during a full course of lung tumor treatments. For 9 lung tumor patients from MD Anderson Cancer Center (MDACC), a total of 70 weekly time-resolved computed tomography (4DCT) datasets were available, which depict the evolution of the patient anatomy over the several fractions of the treatment. Using the GSI in-house treatment planning system (TPS) TRiP4D, 4D simulations were performed on each weekly 4DCT for each patient using gating and optimization of a single treatment plan based on a planning CT acquired prior to treatment. It was found that using a large beam spot size, a short gating window (GW), additional margins and multiple fields permitted to obtain the best results, yielding an average target coverage (V95) of 96.5%. Two motion mitigation techniques, one approximating the rescanning process (multiple irradiations of the target with a fraction of the planned dose) and one combining the latter and gating, were then compared to gating. Both did neither show an improvement in target dose coverage nor in normal tissue sparing. Finally, the total dose delivered to each patient in a simulation of a fractioned treatment was calculated and clinical requirements in terms of target coverage and normal tissue sparing were

  4. Optimized treatment parameters to account for interfractional variability in scanned ion beam therapy of lung cancer

    International Nuclear Information System (INIS)

    Scanned ion beam therapy of lung tumors is severely limited in its clinical applicability by intrafractional organ motion, interference effects between beam and tumor motion (interplay) as well as interfractional anatomic changes. To compensate for dose deterioration by intrafractional motion, motion mitigation techniques, such as gating have been developed. The latter confines the irradiation to a predetermined breathing state, usually the stable end-exhale phase. However, optimization of the treatment parameters is needed to further improve target dose coverage and normal tissue sparing. The aim of the study presented in this dissertation was to determine treatment planning parameters that permit to recover good target coverage and homogeneity during a full course of lung tumor treatments. For 9 lung tumor patients from MD Anderson Cancer Center (MDACC), a total of 70 weekly time-resolved computed tomography (4DCT) datasets were available, which depict the evolution of the patient anatomy over the several fractions of the treatment. Using the GSI in-house treatment planning system (TPS) TRiP4D, 4D simulations were performed on each weekly 4DCT for each patient using gating and optimization of a single treatment plan based on a planning CT acquired prior to treatment. It was found that using a large beam spot size, a short gating window (GW), additional margins and multiple fields permitted to obtain the best results, yielding an average target coverage (V95) of 96.5%. Two motion mitigation techniques, one approximating the rescanning process (multiple irradiations of the target with a fraction of the planned dose) and one combining the latter and gating, were then compared to gating. Both did neither show an improvement in target dose coverage nor in normal tissue sparing. Finally, the total dose delivered to each patient in a simulation of a fractioned treatment was calculated and clinical requirements in terms of target coverage and normal tissue sparing were

  5. Analysis of tyrosine phosphorylation sites in signaling molecules by a phosphotyrosine-specific immonium ion scanning method

    DEFF Research Database (Denmark)

    Steen, Hanno; Pandey, Akhilesh; Andersen, Jens S;

    2002-01-01

    Signal transduction pathways involve cascades of events, such as formation of second messengers and protein complexes that alter the activities of proteins. This can ultimately lead to changes in gene expression in response to the stimuli. Reversible phosphorylation of proteins is an important me...... mechanism for activating or inhibiting enzymes and for the assembly of multiprotein complexes. Here, we describe a mass spectrometry-based phosphotyrosine-specific immonium ion scanning (PSI scanning) method for selective detection of tyrosine-phosphorylated peptides. Once the tyrosine......-phosphorylated peptides are identified, they can be directly sequenced in the same experiment to localize the phosphorylation site. We provide protocols for isolation and preparation of samples for analysis, and detailed instructions for operation of a quadrupole time-of-flight (TOF) mass spectrometer for this method...

  6. Bioinspired Protein Channel-Based Scanning Ion Conductance Microscopy (Bio-SICM) for Simultaneous Conductance and Specific Molecular Imaging.

    Science.gov (United States)

    Macazo, Florika C; White, Ryan J

    2016-03-01

    The utility of stochastic single-molecule detection using protein nanopores has found widespread application in bioanalytical sensing as a result of the inherent signal amplification of the resistive pulse method. Integration of protein nanopores with high-resolution scanning ion conductance microscopy (SICM) extends the utility of SICM by enabling selective chemical imaging of specific target molecules, while simultaneously providing topographical information about the net ion flux through a pore under a concentration gradient. In this study, we describe the development of a bioinspired scanning ion conductance microscopy (bio-SICM) approach that couples the imaging ability of SICM with the sensitivity and chemical selectivity of protein channels to perform simultaneous pore imaging and specific molecule mapping. To establish the framework of the bio-SICM platform, we utilize the well-studied protein channel α-hemolysin (αHL) to map the presence of β-cyclodextrin (βCD) at a substrate pore opening. We demonstrate concurrent pore and specific molecule imaging by raster scanning an αHL-based probe over a glass membrane containing a single 25-μm-diameter glass pore while recording the lateral positions of the probe and channel activity via ionic current. We use the average channel current to create a conductance image and the raw current-time traces to determine spatial localization of βCD. With further optimization, we believe that the bio-SICM platform will provide a powerful analytical methodology that is generalizable, and thus offers significant utility in a myriad of bioanalytical applications. PMID:26848947

  7. Advantages of scanning-mode ion beam analysis for the study of Cultural Heritage

    Science.gov (United States)

    Grassi, N.; Giuntini, L.; Mandò, P. A.; Massi, M.

    2007-03-01

    In this paper, we discuss the convenience of performing external PIXE and PIGE measurements by scanning relatively large areas (some mm2) with a beam size of the order of hundred microns, rather than performing "spot" compositional analysis. Examples of test runs on samples of archaeometric interest are presented: scanning-mode measurements of ancient inks, Roman glass and metal point drawings clearly demonstrate that using this procedure to perform IBA may become fundamental to avoid deceptive information and to obtain more reliable quantitative results.

  8. Carbon fiber composite targets for nuclear fusion technology: a focused ion beam/scanning electron microscope investigation.

    Science.gov (United States)

    Ghezzi, F; Magni, S; Milani, M; Tatti, F

    2007-01-01

    Carbon fiber composite (CFC) targets are investigated by a focused ion beam/scanning electron microscope (FIB/SEM) in a joint project aiming at the development of robust divertors in the International Thermonuclear Experimental Reactor (ITER). These mockups are exposed to a plasma that simulates the off-normal thermal loads foreseen for ITER and display a rich, puzzling impact scenario. Morphological elements are identified at the exposed surface and beneath it, and are examined in order to point out the relevant processes involved. Each technique adopted is discussed and evaluated. PMID:18200678

  9. Analysis of hydrogen distribution on Mg-Ni alloy surface by scanning electron-stimulated desorption ion microscope (SESDIM)

    International Nuclear Information System (INIS)

    Hydrogen distribution and behavior on a Mg-Ni alloy surface are studied by using a time-of-flight electron-stimulated desorption (TOF-ESD) microscopy and a scanning electron microscope with energy dispersive X-ray spectroscopy (SEM-EDX). The desorbed hydrogen ions are energy-discriminated and distinguished into two characters in the adsorbed states, which belong to Mg2Ni grains and the other to oxygen-contaminated Mg phase at the grain boundaries. Adsorbed hydrogen is found to be stable up to 150 deg. C, but becomes thermally unstable around at 200 deg. C

  10. Automated identification and quantification of glycerophospholipid molecular species by multiple precursor ion scanning

    DEFF Research Database (Denmark)

    Ejsing, Christer S.; Duchoslav, Eva; Sampaio, Julio; Simons, Kai; Bonner, Ron; Thiele, Christoph; Ekroos, Kim; Shevchenko, Andrej

    2006-01-01

    We report a method for the identification and quantification of glycerophospholipid molecular species that is based on the simultaneous automated acquisition and processing of 41 precursor ion spectra, specific for acyl anions of common fatty acids moieties and several lipid class-specific fragme...... glycerophospholipids. The automated analysis of total lipid extracts was powered by a robotic nanoflow ion source and produced currently the most detailed description of the glycerophospholipidome.......We report a method for the identification and quantification of glycerophospholipid molecular species that is based on the simultaneous automated acquisition and processing of 41 precursor ion spectra, specific for acyl anions of common fatty acids moieties and several lipid class-specific fragment...... ions. Absolute quantification of identified species was linear within a concentration range of 10 nM-100 microM and was achieved by spiking into total lipid extracts a set of synthetic lipid standards with diheptadecanoyl (17:0/17:0) fatty acid moieties, representing six common classes of...

  11. Scanning transmission ion microscopy (STIM) with a 3 MeV proton cyclotron beam

    Energy Technology Data Exchange (ETDEWEB)

    Maanen, I.F. van [Technische Univ., Eindhoven (Netherlands). Cyclotron Lab.; Mutsaers, P.H.A. [Technische Univ., Eindhoven (Netherlands). Cyclotron Lab.; Verhoef, B.A.W. [Technische Univ., Eindhoven (Netherlands). Cyclotron Lab.; Voigt, M.J.A. de [Technische Univ., Eindhoven (Netherlands). Cyclotron Lab.

    1996-06-01

    A method is developed to optimize the lateral resolution of a scanning proton microprobe using a 3 MeV cyclotron beam. The most important part of the method is the optimization of an asymmetrical quadrupole quadruplet, based on second-order relationships between diaphragm widths and the full width of the spot. A STIM example is presented of cellular structures of rat-heart tissue. (orig.).

  12. Scanning transmission ion microscopy (STIM) with a 3 MeV proton cyclotron beam

    International Nuclear Information System (INIS)

    A method is developed to optimize the lateral resolution of a scanning proton microprobe using a 3 MeV cyclotron beam. The most important part of the method is the optimization of an asymmetrical quadrupole quadruplet, based on second-order relationships between diaphragm widths and the full width of the spot. A STIM example is presented of cellular structures of rat-heart tissue. (orig.)

  13. Dimensional comparison between amplitude-modulation atomic force microscopy and scanning ion conductance microscopy of biological samples

    Science.gov (United States)

    Kim, Joonhui; Choi, MyungHoon; Jung, Goo-Eun; Rahim Ferhan, Abdul; Cho, Nam-Joon; Cho, Sang-Joon

    2016-08-01

    The range of scanning probe microscopy (SPM) applications for atomic force microscopy (AFM) is expanding in the biological sciences field, reflecting an increasing demand for tools that can improve our fundamental understanding of the physics behind biological systems. However, the complexity associated with applying SPM techniques in biomedical research hampers the full exploitation of its capabilities. Recently, the development of scanning ion conductance microscopy (SICM) has overcome these limitations and enabled contact-free, high resolution imaging of live biological specimens. In this work, we demonstrate the limitation of AFM for imaging biological samples in liquid due to artifacts arising from AFM tip–sample interaction, and how SICM imaging is able to overcome those limitations with contact-free scanning. We also demonstrate that SICM measurements, when compared to AFM, show better fit to the actual dimensions of the biological samples. Our results highlight the superiority of SICM imaging, enabling it to be widely adopted as a general and versatile research tool for biological studies in the nanoscale.

  14. Attitude Stabilization Control of a Quadrotor UAV by Using Backstepping Approach

    Directory of Open Access Journals (Sweden)

    Xing Huo

    2014-01-01

    Full Text Available The modeling and attitude stabilization control problems of a four-rotor vertical takeoff and landing unmanned air vehicle (UAV known as the quadrotor are investigated. The quadrotor’s attitude is represented by the unit quaternion rather than Euler angles to avoid singularity problem. Taking dynamical behavior of motors into consideration and ignoring aerodynamic effect, a nonlinear controller is developed to stabilize the attitude. The control design is accomplished by using backstepping control technique. The proposed control law is based on the compensation for the Coriolis and gyroscope torques. Applying Lyapunov stability analysis proves that the closed-loop attitude system is asymptotic stable. Moreover, the controller can guarantee that all the states of the system are uniformly ultimately bounded in the presence of external disturbance torque. The effectiveness of the proposed control approach is analytically authenticated and also validated via simulation study.

  15. Modeling and Backstepping-based Nonlinear Control Strategy for a 6 DOF Quadrotor Helicopter

    Institute of Scientific and Technical Information of China (English)

    Ashfaq Ahmad Mian; Wang Daobo

    2008-01-01

    In this article,a nonlinear model of an underactuated six degrees of freedom (6 DOF) quadrotor helicopter is derived on the basis of the Newton-Euler formalism.The derivation comprises determining equations of the motion of the quadrotor in three dimensions andapproximating the actuation forces through the modeling of aerodynamic coefficients and electric motor dynamics.The derived modelcomposed of translatioual and rotational subsystems is dynamically unstable,so a sequential nonlinear control strategy is used.The con-trol strategy includes feedback linearization coupled with a PD controller for the translational subsystem and a backstepping-based PID nonlinear controller for the rotational subsystem of the quadrotor.The performances of the nonlinear control method are evaluated by nonlinear simulation and the results demonstrate the effectiveness of the proposed control strategy for the quadrotor helicopter inquasi-stationary flights.

  16. Adaptive Backstepping Control Based on Floating Offshore High Temperature Superconductor Generator for Wind Turbines

    Directory of Open Access Journals (Sweden)

    Feng Yang

    2014-01-01

    Full Text Available With the rapid development of offshore wind power, the doubly fed induction generator and permanent magnet synchronous generator cannot meet the increasing request of power capacity. Therefore, superconducting generator should be used instead of the traditional motor, which can improve generator efficiency, reduce the weight of wind turbines, and increase system reliability. This paper mainly focuses on nonlinear control in the offshore wind power system which is consisted of a wind turbine and a high temperature superconductor generator. The proposed control approach is based on the adaptive backstepping method. Its main purpose is to regulate the rotor speed and generator voltage, therefore, achieving the maximum power point tracking (MPPT, improving the efficiency of a wind turbine, and then enhancing the system’s stability and robustness under large disturbances. The control approach can ensure high precision of generator speed tracking, which is confirmed in both the theoretical analysis and numerical simulation.

  17. Design of an adaptive backstepping controller for auto-berthing a cruise ship under wind loads

    Directory of Open Access Journals (Sweden)

    Park Jong-Yong

    2014-06-01

    Full Text Available The auto-berthing of a ship requires excellent control for safe accomplishment. Crabbing, which is the pure sway motion of a ship without surge velocity, can be used for this purpose. Crabbing is induced by a peculiar operation procedure known as the push-pull mode. When a ship is in the push-pull mode, an interacting force is induced by complex turbulent flow around the ship generated by the propellers and side thrusters. In this paper, three degrees of freedom equations of the motions of crabbing are derived. The equations are used to apply the adaptive backstepping control method to the auto-berthing controller of a cruise ship. The controller is capable of handling the system nonlinearity and uncertainty of the berthing process. A control allocation algorithm for a ship equipped with two propellers and two side thrusters is also developed, the performance of which is validated by simulation of auto-berthing.

  18. Trajectory tracking control of underactuated USV based on modified backstepping approach

    Directory of Open Access Journals (Sweden)

    Dong Zaopeng

    2015-09-01

    Full Text Available This paper presents a state feedback based backstepping control algorithm to address the trajectory tracking problem of an underactuated Unmanned Surface Vessel (USV in the horizontal plane. A nonlinear three Degree of Freedom (DOF underactuated dynamic model for USV is considered, and trajectory tracking controller that can track both curve trajectory and straight line trajectory with high accuracy is designed as the well known Persistent Exciting (PE conditions of yaw velocity is completely relaxed in our study. The proposed controller has further been enriched by incorporating an integral action additionally for enhancing the steady state performance and control precision of the USV trajectory tracking control system. Global stability of the overall system is proved by Lyapunov theory and Barbalat’s Lemma, and then simulation experiments are carried out to demonstrate the effectiveness of the controller designed.

  19. Design of an adaptive backstepping controller for auto-berthing a cruise ship under wind loads

    Science.gov (United States)

    Park, Jong-Yong; Kim, Nakwan

    2014-06-01

    The auto-berthing of a ship requires excellent control for safe accomplishment. Crabbing, which is the pure sway motion of a ship without surge velocity, can be used for this purpose. Crabbing is induced by a peculiar operation procedure known as the push-pull mode. When a ship is in the push-pull mode, an interacting force is induced by complex turbulent flow around the ship generated by the propellers and side thrusters. In this paper, three degrees of freedom equations of the motions of crabbing are derived. The equations are used to apply the adaptive backstepping control method to the auto-berthing controller of a cruise ship. The controller is capable of handling the system nonlinearity and uncertainty of the berthing process. A control allocation algorithm for a ship equipped with two propellers and two side thrusters is also developed, the performance of which is validated by simulation of auto-berthing.

  20. Adaptive Backstepping Controller Design for Leveling Control of an Underwater Platform Based on Joint Space

    Directory of Open Access Journals (Sweden)

    Zhi-Lin Zeng

    2014-01-01

    Full Text Available This paper focuses on high precision leveling control of an underwater heavy load platform, which is viewed as an underwater parallel robot on the basis of its work pattern. The kinematic of platform with deformation is analyzed and the dynamics model of joint space is established. An adaptive backstepping controller according to Lyapunov's function is proposed for leveling control of platform based on joint space. Furthermore, the “lowest point fixed angle error” leveling scheme called “chase” is chosen for leveling control of platform. The digital simulation and practical experiment of single joint space actuator are carried out, and the results show high precision servo control of joint space. On the basis of this, the platform leveling control simulation relies on the hardware-in-loop system. The results indicate that the proposed controller can effectively restrain the influence from system parameter uncertainties and external disturbance to realize high precision leveling control of the underwater platform.

  1. Fuzzy Backstepping Torque Control Of Passive Torque Simulator With Algebraic Parameters Adaptation

    Science.gov (United States)

    Ullah, Nasim; Wang, Shaoping; Wang, Xingjian

    2015-07-01

    This work presents fuzzy backstepping control techniques applied to the load simulator for good tracking performance in presence of extra torque, and nonlinear friction effects. Assuming that the parameters of the system are uncertain and bounded, Algebraic parameters adaptation algorithm is used to adopt the unknown parameters. The effect of transient fuzzy estimation error on parameters adaptation algorithm is analyzed and the fuzzy estimation error is further compensated using saturation function based adaptive control law working in parallel with the actual system to improve the transient performance of closed loop system. The saturation function based adaptive control term is large in the transient time and settles to an optimal lower value in the steady state for which the closed loop system remains stable. The simulation results verify the validity of the proposed control method applied to the complex aerodynamics passive load simulator.

  2. Backstepping design of missile guidance and control based on adaptive fuzzy sliding mode control

    Directory of Open Access Journals (Sweden)

    Ran Maopeng

    2014-06-01

    Full Text Available This paper presents an integrated missile guidance and control law based on adaptive fuzzy sliding mode control. The integrated model is formulated as a block-strict-feedback nonlinear system, in which modeling errors, unmodeled nonlinearities, target maneuvers, etc. are viewed as unknown uncertainties. The adaptive nonlinear control law is designed based on backstepping and sliding mode control techniques. An adaptive fuzzy system is adopted to approximate the coupling nonlinear functions of the system, and for the uncertainties, we utilize an online-adaptive control law to estimate the unknown parameters. The stability analysis of the closed-loop system is also conducted. Simulation results show that, with the application of the adaptive fuzzy sliding mode control, small miss distances and smooth missile trajectories are achieved, and the system is robust against system uncertainties and external disturbances.

  3. Backstepping design of missile guidance and control based on adaptive fuzzy sliding mode control

    Institute of Scientific and Technical Information of China (English)

    Ran Maopeng; Wang Qing; Hou Delong; Dong Chaoyang

    2014-01-01

    This paper presents an integrated missile guidance and control law based on adaptive fuzzy sliding mode control. The integrated model is formulated as a block-strict-feedback nonlinear system, in which modeling errors, unmodeled nonlinearities, target maneuvers, etc. are viewed as unknown uncertainties. The adaptive nonlinear control law is designed based on backstepping and sliding mode control techniques. An adaptive fuzzy system is adopted to approximate the coupling nonlinear functions of the system, and for the uncertainties, we utilize an online-adaptive control law to estimate the unknown parameters. The stability analysis of the closed-loop system is also conducted. Simulation results show that, with the application of the adaptive fuzzy sliding mode control, small miss distances and smooth missile trajectories are achieved, and the system is robust against system uncertainties and external disturbances.

  4. A Back-stepping Based Trajectory Tracking Controller for a Non-chained Nonholonomic Spherical Robot

    Institute of Scientific and Technical Information of China (English)

    Zhan Qiang; Liu Zengbo; Cai Yao

    2008-01-01

    Spherical robot has good static and dynamic stability, which provides it with strong viability in hostile environment, but the lack of effective control methods has hindered its application and development. This article deals with the dynamic trajectory tracking problem of the spherical robot BHQ-2 designed for unmanned environment exploration. The dynamic model of the spherical robot is established with a simplified Boltzmann-Hamel equation, based on which a trajectory tracking controller is designed by using the back-stepping method. The convergence of the controller is proved with the Lyapunov stability theory. Numerical simulations show that with the controller the robot can globally and asymptotically track desired trajectories, both linear and circular.

  5. Implementation and initial clinical experience of offline PET/CT-based verification of scanned carbon ion treatment

    International Nuclear Information System (INIS)

    Background and purpose: We report on the implementation of offline PET/CT-based treatment verification at the Heidelberg Ion Beam Therapy Centre (HIT) and present first clinical cases for post-activation measurements after scanned carbon ion irradiation. Key ingredient of this in-vivo treatment verification is the comparison of irradiation-induced patient activation measured by a PET scanner with a prediction simulated by means of Monte Carlo techniques. Material and methods: At HIT, a commercial full-ring PET/CT scanner has been installed in close vicinity to the treatment rooms. After selected irradiation fractions, the patient either walks to the scanner for acquisition of the activation data or is transported using a shuttle system. The expected activity distribution is obtained from the production of β+-active isotopes simulated by the FLUKA code on the basis of the patient-specific treatment plan, post-processed considering the time course of the respective treatment fraction, the estimated biological washout of the induced activity and a simplified model of the imaging process. Results: We present four patients with different indications of head, head/neck, liver and pelvic tumours. A clear correlation between the measured PET signal and the simulated activity pattern is observed for all patients, thus supporting a proper treatment delivery. In the case of a pelvic tumour patient it was possible to detect minor treatment delivery inaccuracies. Conclusions: The initial clinical experience proves the feasibility of the implemented strategy for offline confirmation of scanned carbon ion irradiation and therefore constitutes a first step towards a comprehensive PET/CT-based treatment verification in the clinical routine at HIT

  6. In situ ion etching in a scanning electron microscope and its application to the study of dental restorations

    International Nuclear Information System (INIS)

    The cylindrical version of the Saddle Field ion source has been water-cooled to eliminate radiation from the source which contributes to the rise in temperature of a specimen undergoing ion bombardment. This has also eliminated the problem of the build-up of black contamination on the anodes which causes a deterioration in the performance within the first hour of operation. In the water-cooled source, smooth conducting films are obtained instead of the black uneven deposit, and this gives extremely stable operation for long periods of time. One of these sources has been incorporated into the specimen stage of a scanning electron microscope to provide a facility for the in situ ion etching of all types of materials. A particular problem of the recurrent failure of dental fillings has been studied in some detail and it is believed that this may be due to a thin bridge of amalgam near the interface with the enamel which is removed during etching, exposing a relatively large gap immediately below. A similar process may occur in the oral environment, where this thin layer can be fractured due to mastication, enabling bacteria to penetrate and thus initiate decay. Work is also being carried out in vivo using replication techniques to try to substantiate these findings. (author)

  7. WE-D-BRF-04: Experimental Investigations On Ion Radiography with Beam Scanning Using a Range Telescope

    International Nuclear Information System (INIS)

    Purpose: Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable properties allow superior tumordose conformality, but introduce sensitivity to range uncertainties. Hence, imaging techniques play an increasingly important role to support the treatment planning and the in-vivo monitoring of the actual ion beam treatment. Methods: This work presents the experimental investigations carried out to address the feasibility of ion transmission imaging at the Heidelberg Ion Therapy center using an active raster scanning beam delivery system and a prototype range telescope set-up based on a stack of 61 parallel-plate ionization chambers (PPIC) interleaved with 3 mm absorber plates of PMMA. Results: An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed and results will be presented. A data processing method to increase the range resolution (MIRR) of the PPIC stack was developed. In this approach, the position of the maximum of the Bragg curve is deduced from the ratio of measured signals in adjacent PPIC channels. MIRR evaluation is based on Bragg curves obtained from Monte Carlo simulations and validated with experimental data acquired with the PPIC stack using ion beams. MIRR was applied to the carbon ion radiography of an anthropomorphic Alderson head phantom yielding a resolution of 0.8 mm water equivalent thickness (WET) compared to the nominal value of 3.495 mm WET given by the thickness of the absorber slabs in the PPIC stack. An absolute comparison of the Alderson phantom carbon ion transmitted image with an X-ray digitally reconstructed radiography, both converted into WET, will also be shown. Conclusion: The obtained results are very promising and motivate further developments of the system towards an eventual clinical use.This work is supported by the German Research Foundation and the German Academic Exchange Service. This work is supported by the

  8. FIELD ION MICROSCOPE AND ATOM-PROBE STUDIES OF SCANNING TUNNELING MICROSCOPE TIPS

    OpenAIRE

    Nishikawa, O.; K. Hattori; Katsuki, F.; Tomitori, M.

    1988-01-01

    Tungsten and platinum-iridium alloy tips were observed by field emission and ion microscopes and were atom-probe mass analyzed to examine the tip surfaces corroded by exposure to air and by immersion into aqueous solutions. Although the A-P analysis indicates that the corroded layer is less than monoatomic thick for both W and Pt-Ir, the FEM and FIM observation indicates that exposure to air and immersion into solutions often result in the formation of a small protrusion at the tip apex. The ...

  9. Apparent beam size definition of focused ion beams based on scanning electron microscopy images of nanodots

    OpenAIRE

    Vladov, Nikola; Segal, Joel; Ratchev, Svetan

    2015-01-01

    In this paper the new term apparent beam size of Focused Ion Beam (FIB) is introduced and an original method of its evaluation is demonstrated. Traditional methods of measuring the beam size, like the knife edge method, provide information about the quality of the beam itself but practically they do not give information on the FIB sputtering resolution. To do this, it is necessary to take into account the material dependant interaction of the beam with the specimen and the gas precursor in th...

  10. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion

    DEFF Research Database (Denmark)

    Fuchs, Hermann; Alber, Markus; Schreiner, Thomas;

    2015-01-01

    PURPOSE: Helium ions ((4)He) may supplement current particle beam therapy strategies as they possess advantages in physical dose distribution over protons. To assess potential clinical advantages, a dose calculation module accounting for relative biological effectiveness (RBE) was developed and...... Bragg-peak region, which was then kept constant over the fragmentation tail. To account for a variable proton RBE, the same model concept was also applied to protons with a maximum RBE of 1.6. Both RBE models were added to a previously developed pencil beam algorithm for physical dose calculation and...... included into the treatment planning system Hyperion. The implementation was validated against Monte Carlo simulations within a water phantom using γ-index evaluation. The potential benefits of (4)He based treatment plans were explored in a preliminary treatment planning comparison (against protons) for...

  11. Characterization of nanometer-scale porosity in reservoir carbonate rock by focused ion beam-scanning electron microscopy.

    Science.gov (United States)

    Bera, Bijoyendra; Gunda, Naga Siva Kumar; Mitra, Sushanta K; Vick, Douglas

    2012-02-01

    Sedimentary carbonate rocks are one of the principal porous structures in natural reservoirs of hydrocarbons such as crude oil and natural gas. Efficient hydrocarbon recovery requires an understanding of the carbonate pore structure, but the nature of sedimentary carbonate rock formation and the toughness of the material make proper analysis difficult. In this study, a novel preparation method was used on a dolomitic carbonate sample, and selected regions were then serially sectioned and imaged by focused ion beam-scanning electron microscopy. The resulting series of images were used to construct detailed three-dimensional representations of the microscopic pore spaces and analyze them quantitatively. We show for the first time the presence of nanometer-scale pores (50-300 nm) inside the solid dolomite matrix. We also show the degree of connectivity of these pores with micron-scale pores (2-5 μm) that were observed to further link with bulk pores outside the matrix. PMID:22214656

  12. Identified particle production and freeze-out properties in heavy-ion collisions at RHIC Beam Energy Scan program

    CERN Document Server

    ,

    2014-01-01

    The first phase of Beam Energy Scan (BES) program at the Relativistic Heavy-Ion Collider (RHIC) was started in the year 2010 with the aim to study the several aspects of the quantum chromodynamics (QCD) phase diagram. The Solenoidal Tracker At RHIC (STAR) detector has taken data at $\\sqrt{s_{NN}} = $ 7.7, 11.5, 19.6, 27, and 39 GeV in Au+Au collisions in the years 2010 and 2011 as part of the BES programme. For these beam energies, we present the results on the particle yields, average transverse mass and particle ratios for identified particles in mid-rapidity ($|y|$ < 0.1). The measured particle ratios have been used to study the chemical freeze-out dynamics within the framework of a statistical model.

  13. Identified particle production and freeze-out properties in heavy-ion collisions at RHIC Beam Energy Scan program

    Directory of Open Access Journals (Sweden)

    Das Sabita

    2015-01-01

    Full Text Available The first phase of Beam Energy Scan (BES program at the Relativistic Heavy-Ion Collider (RHIC was started in the year 2010 with the aim to study the several aspects of the quantum chromodynamics (QCD phase diagram. The Solenoidal Tracker At RHIC (STAR detector has taken data at √sNN = 7.7, 11.5, 19.6, 27, and 39 GeV in Au+Au collisions in the years 2010 and 2011 as part of the BES programme. For these beam energies, we present the results on the particle yields, average transverse mass and particle ratios for identified particles in mid-rapidity (|y| < 0.1. The measured particle ratios have been used to study the chemical freezeout dynamics within the framework of a statistical model.

  14. Recent experimental studies of ion acceleration driven by intense laser radiation pressure - Parametric scan and energy scaling

    International Nuclear Information System (INIS)

    Radiation Pressure Acceleration (RPA) mechanism is currently attracting a substantial amount of experimental and theoretical attention worldwide. Employing the Petawatt laser of the Rutherford Appleton Laboratory, UK, both the Hole-boring (HB) and Light sail (LS) regimes of RPA have been extensively explored by scanning over wide range of laser and target parameters. The dominant role of laser radiation pressure in such intense interaction conditions resulted in narrow band heavy ion spectra, where the ion energy scales with [Iτ/ξ)15 (I, τ and ξ stand for laser intensity, pulse duration and target areal density respectively] - significantly faster than the competing 'Target Normal Sheath Acceleration' mechanism (E oc I0.5). The aftermath of RPA is observed in the late time (0.1 -1 ns) evolution of collimated plasma jets ejected from the target rear surface, detected by ps time resolved transverse interferometry. Significant Improvement in spatial uniformity of the plasma jet density profile observed for circularly polarised laser compared to linear, polarisation is a clear indicative of the role played by circular polarisation towards stability of the RPA. (author)

  15. Combining operando synchrotron X-ray tomographic microscopy and scanning X-ray diffraction to study lithium ion batteries.

    Science.gov (United States)

    Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa

    2016-01-01

    We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions. PMID:27324109

  16. Tumor tracking based on correlation models in scanned ion beam therapy: an experimental study

    International Nuclear Information System (INIS)

    Accurate dose delivery to extra-cranial lesions requires tumor motion compensation. An effective compensation can be achieved by real-time tracking of the target position, either measured in fluoroscopy or estimated through correlation models as a function of external surrogate motion. In this work, we integrated two internal/external correlation models (a state space model and an artificial neural network-based model) into a custom infra-red optical tracking system (OTS). Dedicated experiments were designed and conducted at GSI (Helmholtzzentrum für Schwerionenforschung). A robotic breathing phantom was used to reproduce regular and irregular internal target motion as well as external thorax motion. The position of a set of markers placed on the phantom thorax was measured with the OTS and used by the correlation models to infer the internal target position in real-time. Finally, the estimated target position was provided as input for the dynamic steering of a carbon ion beam. Geometric results showed that the correlation models transversal (2D) targeting error was always lower than 1.3 mm (root mean square). A significant decrease of the dosimetric error with respect to the uncompensated irradiation was achieved in four out of six experiments, demonstrating that phase shifts are the most critical irregularity for external/internal correlation models. (paper)

  17. Patient-specific QA and delivery verification of scanned ion beam at NIRS-HIMAC

    Energy Technology Data Exchange (ETDEWEB)

    Furukawa, Takuji; Inaniwa, Taku; Hara, Yousuke; Mizushima, Kota; Shirai, Toshiyuki; Noda, Koji [Medical Physics Research Group, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2013-12-15

    Purpose: To evaluate a patient-specific QA program and system for constancy checking of a scanning delivery system developed at the National Institute of Radiological Sciences.Methods: For the patient-specific QA, all the planned beams are recalculated on a water phantom with treatment planning software (TPS). The recalculated dose distributions are compared with the measured distributions using a 2D ionization chamber array at several depths, and evaluated using gamma index analysis with criteria of 3% and 3 mm and a pass rate of 90%. For the constancy check, the authors developed the multiwire proportional chamber (MWPC), which can record the delivered 2D fluence images in a slice-by-slice manner. During irradiation for dosimetric QA with the 2D ionization chamber array and an accordion-type water phantom, the 2D fluence images are recorded using the MWPC in the delivery system. These recorded images are then compared to those taken in the treatment session to check the constancy check. This analysis also employs gamma index analysis using the same criteria as in the patient-specific QA. These patient-specific QA and constancy check evaluations were performed using the data of 122 patients.Results: In the patient-specific QA, the measured dose distributions agreed well with those calculated by the TPS, and the QA criteria were satisfied in all measurements. The additional check of the fluence comparison ensured the constancy of the delivered field during each treatment irradiation.Conclusions: The authors established a patient-specific QA program and additional check of delivery constancy in every treatment session. Fluence comparison is a strong tool for constancy checking of the delivery system.

  18. Realization of a scanning ion beam monitor; Realisation d'un dispositif de controle et d'imagerie de faisceaux balayes d'ions

    Energy Technology Data Exchange (ETDEWEB)

    Pautard, C

    2008-07-15

    During this thesis, a scanning ion beam monitor has been developed in order to measure on-line fluence spatial distributions. This monitor is composed of an ionization chamber, Hall Effect sensors and a scintillator. The ionization chamber set between the beam exit and the experiment measures the ion rate. The beam spot is localized thanks to the Hall Effect sensors set near the beam sweeping magnets. The scintillator is used with a photomultiplier tube to calibrate the ionization chamber and with an imaging device to calibrate the Hall Effect sensors. This monitor was developed to control the beam lines of a radiobiology dedicated experimentation room at GANIL. These experiments are held in the context of the research in hadron-therapy. As a matter of fact, this new cancer treatment technique is based on ion irradiations and therefore demands accurate knowledge about the relation between the dose deposit in biological samples and the induced effects. To be effective, these studies require an on-line control of the fluence. The monitor has been tested with different beams at GANIL. Fluence can be measured with a relative precision of {+-}4% for a dose rate ranging between 1 mGy/s and 2 Gy/s. Once permanently set on the beam lines dedicated to radiobiology at GANIL, this monitor will enable users to control the fluence spatial distribution for each irradiation. The scintillator and the imaging device are also used to control the position, the spot shape and the energy of different beams such as those used for hadron-therapy. (author)

  19. Improved 6-Plex Tandem Mass Tags Quantification Throughput Using a Linear Ion Trap-High-Energy Collision Induced Dissociation MS(3) Scan.

    Science.gov (United States)

    Liu, Jane M; Sweredoski, Michael J; Hess, Sonja

    2016-08-01

    The use of tandem mass tags (TMT) as an isobaric labeling strategy is a powerful method for quantitative proteomics, yet its accuracy has traditionally suffered from interference. This interference can be largely overcome by selecting MS(2) fragment precursor ions for high-energy collision induced dissociation (HCD) MS(3) analysis in an Orbitrap scan. While this approach minimizes the interference effect, sensitivity suffers due to the high AGC targets and long acquisition times associated with MS(3) Orbitrap detection. We investigated whether acquiring the MS(3) scan in a linear ion trap with its lower AGC target would increase overall quantification levels with a minimal effect on precision and accuracy. Trypsin-digested proteins from Saccharomyces cerevisiae were tagged with 6-plex TMT reagents. The sample was subjected to replicate analyses using either the Orbitrap or the linear ion trap for the HCD MS(3) scan. HCD MS(3) detection in the linear ion trap vs Orbitrap increased protein identification by 66% with minor loss in precision and accuracy. Thus, the use of a linear ion trap-HCD MS(3) scan during a 6-plex TMT experiment can improve overall identification levels while maintaining the power of multiplexed quantitative analysis. PMID:27377715

  20. Adaptive backstepping control for levitation system with load uncertainties and external disturbances

    Institute of Scientific and Technical Information of China (English)

    李金辉; 李杰; 余佩; 王连春

    2014-01-01

    To explore the precise dynamic response of the levitation system with active controller, a maglev guide way-electromagnet-air spring-cabin coupled model is derived firstly. Based on the mathematical model, it shows that the inherent nonlinearity, inner coupling, misalignments between the sensors and actuators, load uncertainties and external disturbances are the main issues that should be solved in engineering. Under the assumptions that the loads and external disturbance are measurable, the backstepping module controller developed in this work can tackle the above problems effectively. In reality, the load is uncertain due to the additions of luggage and passengers, which will degrade the dynamic performance. A load estimation algorithm is introduced to track the actual load asymptotically and eliminate its influence by tuning the parameters of controller online. Furthermore, considering the external disturbances generated by crosswind, pulling motor and air springs, the extended state observer is employed to estimate and suppress the external disturbance. Finally, results of numerical simulations illustrating closed-loop performance are provided.

  1. Advancing Control for Shield Tunneling Machine by Backstepping Design with LuGre Friction Model

    Directory of Open Access Journals (Sweden)

    Haibo Xie

    2014-01-01

    Full Text Available Shield tunneling machine is widely applied for underground tunnel construction. The shield machine is a complex machine with large momentum and ultralow advancing speed. The working condition underground is rather complicated and unpredictable, and brings big trouble in controlling the advancing speed. This paper focused on the advancing motion control on desired tunnel axis. A three-state dynamic model was established with considering unknown front face earth pressure force and unknown friction force. LuGre friction model was introduced to describe the friction force. Backstepping design was then proposed to make tracking error converge to zero. To have a comparison study, controller without LuGre model was designed. Tracking simulations of speed regulations and simulations when front face earth pressure changed were carried out to show the transient performances of the proposed controller. The results indicated that the controller had good tracking performance even under changing geological conditions. Experiments of speed regulations were carried out to have validations of the controllers.

  2. Analysis of shape and spatial interaction of synaptic vesicles using data from focused ion beam scanning electron microscopy (FIB-SEM)

    DEFF Research Database (Denmark)

    Khanmohammadi, Mahdieh; Waagepetersen, Rasmus Plenge; Sporring, Jon

    2015-01-01

    deviations from spherical shape and systematic trends in their orientation. We studied three-dimensional representations of synapses obtained by manual annotation of focused ion beam scanning electron microscopy (FIB-SEM) images of male mouse brain. The configurations of synaptic vesicles were regarded...

  3. Rapid screening of glutathione-trapped reactive metabolites by linear ion trap mass spectrometry with isotope pattern-dependent scanning and postacquisition data mining.

    Science.gov (United States)

    Ma, Li; Wen, Bo; Ruan, Qian; Zhu, Mingshe

    2008-07-01

    The present study describes a novel integrated approach for rapid analysis of reactive metabolites with a linear ion trap mass spectrometer (LTQ). In this approach, an isotope pattern-dependent scanning method was applied to the data acquisition of glutathione (GSH)-trapped reactive metabolites. Recorded full-scan MS and MS/MS data sets were further processed with neutral loss filtering, product ion filtering, and extracted ion chromatographic analysis to search for protonated molecules and MS/MS spectra of GSH adducts. To evaluate the effectiveness and reliability of the approach, GSH adducts of carbamazepine, diclofenac, 4-ethylphenol, acetaminophen, p-cresol, and omeprazole were analyzed, which were formed in human liver microsome incubations fortified with a mixture of nonlabeled GSH and stable isotope-labeled GSH at a 1:0.8 ratio. Results demonstrate that the combination of the isotope pattern-dependent scanning with the postacquisition data mining was very effective in detecting low levels of GSH adducts, regardless of their fragmentation patterns. As compared to a neutral loss scanning method performed with a triple quadrupole mass spectrometer, the LTQ-based approach had several major advantages, including the superior selectivity and sensitivity in detecting different classes of GSH adducts and the higher throughput capability of the detection and MS/MS spectral acquisition of GSH adducts in a single LC/MS run. Overall, this analytical approach provides a simple and efficient means for screening for reactive metabolites using a linear ion trap LC/MS platform. PMID:18549250

  4. Screening of polycyclic polyprenylated acylphloroglucinols from Garcinia species using precursor ion discovery (PID) scan and ultra performance liquid chromatography electrospray ionization Q-TOF tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Yan; Huang, Sheng-Xiong; Song, Jing-Zheng; Qiao, Chun-Feng; Li, Song-Lin; Han, Quan-Bin; Xu, Hong-Xi

    2009-10-01

    A strategy was newly developed to rapidly screen polycyclic polyprenylated acyl-phloroglucinols (PPAPs) from the plant matrices of nine Garcinia species using ultra-performance liquid chromatography (UPLC) coupled with comprehensive mass spectrometric approaches including precursor ion discovery (PID) and tandem mass (MS/MS) scans. The PPAPs share the same diagnostic product ion at m/z 177.02 in positive MS/MS scan, which may be increased as the base peak by ramping the cone voltage from 45 to 100 V. With this ramping cone voltage PID scan, it is feasible to selectively screen the PPAPs from 29 samples of nine Garcinia species. This approach has proven to be a powerful, highly selective, and sensitive tool for rapid screening and detection of nontargeted components in natural products before the purification and structural elucidation process. PMID:19643632

  5. Characterization of stainless steel through Scanning Electron Microscopy, nitrided in the process of implantation of immersed ions in plasma

    International Nuclear Information System (INIS)

    The present project carries out the investigation of the nitridation of the austenitic stainless steel schedule 304, applying the novel technology of installation of nitrogen ions in immersed materials in plasma (Plll), by means of which they modify those properties of the surface of the steel. The obtained results by means of tests of Vickers microhardness, shows that the hardness was increment from 266 to 740 HV (microhardness units). It was determined by means of scanning electron microscopy, the one semiquantitative chemical analysis of the elements that constitute the austenitic stainless steel schedule 304; the obtained results, show to the nitrogen like an element of their composition in the pieces where carried out to end the PIII technology. The parameters of the plasma with which carried out the technology Plll, were monitored and determined by means of electric probes, and with which it was determined that the density of particles is stable in the interval of 1x10-1 at 3x10-1Torr, and it is where better results of hardness were obtained. That reported in this work, they are the first results obtained when applying the technology Plll in Mexico, and with base in these, it is even necessary to investigate and to deepen until to dominate the process and to be in possibilities of proposing it to be carried out and exploited in an industrial way. (Author)

  6. Comparative morphology analysis of live blood platelets using scanning ion conductance and robotic dark-field microscopy.

    Science.gov (United States)

    Kraus, Max-Joseph; Seifert, Jan; Strasser, Erwin F; Gawaz, Meinrad; Schäffer, Tilman E; Rheinlaender, Johannes

    2016-09-01

    Many conventional microscopy techniques for investigating platelet morphology such as electron or fluorescence microscopy require highly invasive treatment of the platelets such as fixation, drying and metal coating or staining. Here, we present two unique but entirely different microscopy techniques for direct morphology analysis of live, unstained platelets: scanning ion conductance microscopy (SICM) and robotic dark-field microscopy (RDM). We demonstrate that both techniques allow for a quantitative evaluation of the morphological features of live adherent platelets. We show that their morphology can be quantified by both techniques using the same geometric parameters and therefore can be directly compared. By imaging the same identical platelets subsequently with SICM and RDM, we found that area, perimeter and circularity of the platelets are directly correlated between SICM and dark-field microscopy (DM), while the fractal dimension (FD) differed between the two microscopy techniques. We show that SICM and RDM are both valuable tools for the ex vivo investigation of the morphology of live platelets, which might contribute to new insights into the physiological and pathophysiological role of platelet spreading. PMID:27063564

  7. Scanned ion beam therapy for prostate carcinoma. Comparison of single plan treatment and daily plan-adapted treatment

    International Nuclear Information System (INIS)

    Intensity-modulated particle therapy (IMPT) for tumors showing interfraction motion is a topic of current research. The purpose of this work is to compare three treatment strategies for IMPT to determine potential advantages and disadvantages of ion prostate cancer therapy. Simulations for three treatment strategies, conventional one-plan radiotherapy (ConvRT), image-guided radiotherapy (IGRT), and online adaptive radiotherapy (ART) were performed employing a dataset of 10 prostate cancer patients with six CT scans taken at one week intervals. The simulation results, using a geometric margin concept (7-2 mm) as well as patient-specific internal target volume definitions for IMPT were analyzed by target coverage and exposure of critical structures on single fraction dose distributions. All strategies led to clinically acceptable target coverage in patients exhibiting small prostate motion (mean displacement < 4 mm), but IGRT and especially ART led to significant sparing of the rectum. In 20 % of the patients, prostate motion exceeded 4 mm causing insufficient target coverage for ConvRT (V95mean = 0.86, range 0.63-0.99) and IGRT (V95mean = 0.91, range 0.68-1.00), while ART maintained acceptable target coverage. IMPT of prostate cancer demands consideration of rectal sparing and adaptive treatment replanning for patients exhibiting large prostate motion. (orig.)

  8. 3D Plant Cell Architecture of Arabidopsis thaliana (Brassicaceae Using Focused Ion Beam–Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Bhawana

    2014-06-01

    Full Text Available Premise of the study: Focused ion beam–scanning electron microscopy (FIB-SEM combines the ability to sequentially mill the sample surface and obtain SEM images that can be used to create 3D renderings with micron-level resolution. We have applied FIB-SEM to study Arabidopsis cell architecture. The goal was to determine the efficacy of this technique in plant tissue and cellular studies and to demonstrate its usefulness in studying cell and organelle architecture and distribution. Methods: Seed aleurone, leaf mesophyll, stem cortex, root cortex, and petal lamina from Arabidopsis were fixed and embedded for electron microscopy using protocols developed for animal tissues and modified for use with plant cells. Each sample was sectioned using the FIB and imaged with SEM. These serial images were assembled to produce 3D renderings of each cell type. Results: Organelles such as nuclei and chloroplasts were easily identifiable, and other structures such as endoplasmic reticula, lipid bodies, and starch grains were distinguishable in each tissue. Discussion: The application of FIB-SEM produced 3D renderings of five plant cell types and offered unique views of their shapes and internal content. These results demonstrate the usefulness of FIB-SEM for organelle distribution and cell architecture studies.

  9. Study on the dose response characteristics of a scanning liquid ion-chamber electronic portal imaging device

    CERN Document Server

    Ma Shao Gang; Song Yi Xin

    2002-01-01

    Objective: To study the dose response characteristics and the influence factors such as gantry angle, field size and acquisition mode on the dosimetric response curves, when using a scanning liquid ion-chamber electronic portal imaging device (EPID) for dose verification. Methods: All experiments were carried out on a Varian 600 C/D accelerator (6 MV X-ray) equipped with a Varian PortalVision sup T sup M MK2 type EPID. To obtain the dose response curve, the relationship between the incident radiation intensity to the detector and the pixel value output from the EPID were established. Firstly, the different dose rates of 6 MV X-rays were obtained by varying SSD. Secondly, three digital portal images were acquired for each dose rate using the EPID and averaged to avoid the influence of the dose rate fluctuations of the accelerator. The pixel values of all images were read using self-designed image analysis software, and and average for a region consisting of 11 x 11 pixels around the center was taken as the res...

  10. Application of Adaptive Backstepping Sliding Mode Control in Alternative Current Servo System of Rocket Launcher%Application of Adaptive Backstepping Sliding Mode Control in Alternative Current Servo System of Rocket Launcher

    Institute of Scientific and Technical Information of China (English)

    郭亚军; 马大为; 王晓峰; 乐贵高

    2011-01-01

    An adaptive backstepping sliding mode control approach is introduced to control the pitch motion of a rocket launcher. Its control law is proposed to guarantee that the control system is ultimately bounded in a Lyapunov sense and make the servo system track the instruction of reference position globally and asymptotically. In addition, the sliding mode control can restrain the effects of parameter uncertainties and external disturbance. The functions of adaptive mechanism and sliding mode control are analyzed through the simulation in the different conditions. The simulation results illustrate that the method is applicable and robust.

  11. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    International Nuclear Information System (INIS)

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA’s nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition

  12. A General Response System Control Method Based on Backstepping Design for Synchronization of Continuous Scalar Chaotic Signal

    Institute of Scientific and Technical Information of China (English)

    WANG Jing; GAO Jin-Feng; MA Xi-Kui; LIANG Zhan-Hong

    2006-01-01

    @@ A general response system control method for synchronization of continuous scalar chaotic signal is presented. The proposed canonical general response system can cover most of the well-known chaotic systems. Conversely, each of these chaotic systems can also be used to construct the general response system. Furthermore, a novel controller of the proposed response system is designed based on backstepping technique, with which the output of the general response system and the given continuous chaotic signal can synchronize perfectly. Two numerical examples are given to illustrate the effectiveness of the proposed control method.

  13. Non-linear control of variable-speed wind turbines with permanent magnet synchronous generators: a robust backstepping approach

    Science.gov (United States)

    Şeker, Murat; Zergeroğlu, Erkan; Tatlicioğlu, Enver

    2016-01-01

    In this study, a robust backstepping approach for the control problem of the variable-speed wind turbine with a permanent magnet synchronous generator is presented. Specifically, to overcome the negative effects of parametric uncertainties in both mechanical and electrical subsystems, a robust controller with a differentiable compensation term is proposed. The proposed methodology ensures the generator velocity tracking error to uniformly approach a small bound where practical tracking is achieved. Stability of the overall system is ensured by Lyapunov-based arguments. Comparative simulation studies with a standard proportional-integral-type controller are performed to illustrate the effectiveness, feasibility and efficiency of the proposed controller.

  14. Neutral Particle Analyzer Vertically Scanning Measurements of MHD-induced Energetic Ion Redistribution or Loss in the National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    S.S. Medley, R. Andre, R.E. Bell, D.S. Darrow, C.W. Domier, E.D. Fredrickson, N.N. Gorelenkov, S.M. Kaye, B.P. LeBlanc, K.C. Lee, F.M. Levinton, D. Liu, N.C. Luhmann, Jr., J.E. Menard, H. Park, D. Stutman, A.L. Roquemore, K. Tritz, H. Yuh and the NSTX Team

    2007-11-15

    Observations of magneto-hydro-dynamic (MHD) induced redistribution or loss of energetic ions measured using the vertically scanning capability of the Neutral Particle Analyzer diagnostic on the National Spherical Torus Experiment (NSTX) are presented along with TRANSP and ORBIT code analysis of the results. Although redistribution or loss of energetic ions due to bursting fishbone-like and low-frequency (f ~ 10 kHz) kinktype MHD activity has been reported previously, the primary goal of this work is to study redistribution or loss due to continuous Alfvénic (f ~ 20 – 150 kHz) modes, a topic that heretofore has not been investigated in detail for NSTX plasmas. Initial indications are that the former drive energetic ion loss whereas the continuous Alfvénic modes only cause redistribution and the energetic ions remain confined.

  15. Neutral Particle Analyzer Vertically Scanning Measurements of MHD-induced Energetic Ion Redistribution or Loss in the National Spherical Torus Experiment

    International Nuclear Information System (INIS)

    Observations of magneto-hydro-dynamic (MHD) induced redistribution or loss of energetic ions measured using the vertically scanning capability of the Neutral Particle Analyzer diagnostic on the National Spherical Torus Experiment (NSTX) are presented along with TRANSP and ORBIT code analysis of the results. Although redistribution or loss of energetic ions due to bursting fishbone-like and low-frequency (f ∼ 10 kHz) kinktype MHD activity has been reported previously, the primary goal of this work is to study redistribution or loss due to continuous Alfvenic (f ∼ 20-150 kHz) modes, a topic that heretofore has not been investigated in detail for NSTX plasmas. Initial indications are that the former drive energetic ion loss whereas the continuous Alfvenic modes only cause redistribution and the energetic ions remain confined.

  16. Site-specific, cross-sectional imaging of biomaterials and the cell/biomaterial interface using focused ion beam/scanning electron microscopy

    International Nuclear Information System (INIS)

    Focused ion beam / scanning electron microscopy (FIBSEM) procedures are examined for the sectioning of biological cell / biomedical implant materials. Conventional site-specific lift-out techniques enable the structural characterisation of hydroxyapatite/Ti coatings. Cryo-FIBSEM procedures, as used to investigate human osteoblasts/ hydroxyapatite/Ti structures, emphasise the need for the repeated deposition of coating layers to protect such delicate structures and to minimise beam curtaining effects.

  17. Commande de vol non lineaire d'un drone a voilure fixe par la methode du backstepping

    Science.gov (United States)

    Finoki, Edouard

    This thesis describes the design of a non-linear controller for a UAV using the backstepping method. It is a fixed-wing UAV, the NexSTAR ARF from HobbicoRTM. The aim is to find the expressions of the aileron, the elevator, and the rudder deflection in order to command the flight path angle, the heading angle and the sideslip angle. Controlling the flight path angle allows a steady, climb or descent flight, controlling the heading cap allows to choose the heading and annul the sideslip angle allows an efficient flight. A good technical control has to ensure the stability of the system and provide optimal performances. Backstepping interlaces the choice of a Lyapunov function with the design of feedback control. This control technique works with the true non-linear model without any approximation. The procedure is to transform intermediate state variables into virtual inputs which will control other state variables. Advantages of this technique are its recursivity, its minimum control effort and its cascaded structure that allows dividing a high order system into several simpler lower order systems. To design this non-linear controller, a non-linear model of the UAV was used. Equations of motion are very accurate, aerodynamic coefficients result from interpolations between several essential variables in flight. The controller has been implemented in Matlab/Simulink and FlightGear.

  18. SU-E-T-562: Scanned Percent Depth Dose Curve Discrepancy for Photon Beams with Physical Wedge in Place (Varian IX) Using Different Sensitive Volume Ion Chambers

    International Nuclear Information System (INIS)

    Purpose: To investigate and report the discrepancy of scanned percent depth dose (PDD) for photon beams with physical wedge in place when using ion chambers with different sensitive volumes. Methods/Materials: PDD curves of open fields and physical wedged fields (15, 30, 45, and 60 degree wedge) were scanned for photon beams (6MV and 10MV, Varian iX) with field size of 5x5 and 10x10 cm using three common scanning chambers with different sensitive volumes - PTW30013 (0.6cm3), PTW23323 (0.1cm3) and Exradin A16 (0.007cm3). The scanning system software used was OmniPro version 6.2, and the scanning water tank was the Scanditronix Wellhoffer RFA 300.The PDD curves from the three chambers were compared. Results: Scanned PDD curves of the same energy beams for open fields were almost identical between three chambers, but the wedged fields showed non-trivial differences. The largest differences were observed between chamber PTW30013 and Exradin A16. The differences increased as physical wedge angle increased. The differences also increased with depth, and were more pronounced for 6MV beam. Similar patterns were shown for both 5x5 and 10x10 cm field sizes. For open fields, all PDD values agreed with each other within 1% at 10cm depth and within 1.62% at 20 cm depth. For wedged fields, the difference of PDD values between PTW30013 and A16 reached 4.09% at 10cm depth, and 5.97% at 20 cm depth for 6MV with 60 degree physical wedge. Conclusion: We observed a significant difference in scanned PDD curves of photon beams with physical wedge in place obtained when using different sensitive volume ion chambers. The PDD curves scanned with the smallest sensitive volume ion chamber showed significant difference from larger chamber results, beyond 10cm depth. We believe this to be caused by varying response to beam hardening by the wedges

  19. Rapid phase-correlated rescanning irradiation improves treatment time in carbon-ion scanning beam treatment under irregular breathing

    Science.gov (United States)

    Mori, Shinichiro; Furukawa, Takuji

    2016-05-01

    To shorten treatment time in pencil beam scanning irradiation, we developed rapid phase-controlled rescanning (rPCR), which irradiates two or more isoenergy layers in a single gating window. Here, we evaluated carbon-ion beam dose distribution with rapid and conventional PCR (cPCR). 4 dimensional computed tomography (4DCT) imaging was performed on 12 subjects with lung or liver tumors. To compensate for intrafractional range variation, the field-specific target volume (FTV) was calculated using 4DCT within the gating window (T20–T80). We applied an amplitude-based gating strategy, in which the beam is on when the tumor is within the gating window defined by treatment planning. Dose distributions were calculated for layered phase-controlled rescanning under an irregular respiratory pattern, although a single 4DCT data set was used. The number of rescannings was eight times. The prescribed doses were 48 Gy(RBE)/1 fr (where RBE is relative biological effectiveness) delivered via four beam ports to the FTV for the lung cases and 45 Gy(RBE)/2 fr delivered via two beam ports to the FTV for the liver cases. In the liver cases, the accumulated dose distributions showed an increased magnitude of hot/cold spots with rPCR compared with cPCR. The results of the dose assessment metrics for the cPCR and rPCR were very similar. The D 95, D max, and D min values (cPCR/rPCR) averaged over all the patients were 96.3  ±  0.9%/96.0  ±  1.2%, 107.3  ±  3.6%/107.1  ±  2.9%, and 88.8  ±  3.2%/88.1  ±  3.1%, respectively. The treatment times in cPCR and rPCR were 110.7 s and 53.5 s, respectively. rPCR preserved dose conformation under irregular respiratory motion and reduced the total treatment time compared with cPCR.

  20. Geant4 simulation for a study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas with the active scanning system at CNAO

    Science.gov (United States)

    Farina, E.; Piersimoni, P.; Riccardi, C.; Rimoldi, A.; Tamborini, A.; Ciocca, M.

    2015-12-01

    The aim of this work was to study a possible use of carbon ion pencil beams (delivered with active scanning modality) for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO). The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radio-biological effectiveness (RBE). The Monte Carlo (MC) Geant4 10.00 toolkit was used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, was used as target. Cross check with previous studies at CNAO using protons allowed comparisons on possible benefits on using such a technique with respect to proton beams. Experimental data on proton and carbon ion beams transverse distributions were used to validate the simulation.

  1. Scanned ion beam therapy for prostate carcinoma. Comparison of single plan treatment and daily plan-adapted treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hild, Sebastian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); University Clinic Erlangen and Friedrich- Alexander-University Erlangen-Nuernberg (FAU), Department of Radiation Oncology, Erlangen (Germany); Graeff, Christian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); Rucinski, Antoni [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Sapienza Universit' a di Roma, Dipartimento di Scienze di Base e Applicate per Ingegneria, Roma (Italy); INFN, Roma (Italy); Zink, Klemens [University of Applied Sciences, Institute for Medical Physics and Radiation Protection, Giessen (Germany); University Medical Center Giessen-Marburg, Department of Radiotherapy and Radiooncology, Marburg (Germany); Habl, Gregor [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Klinikum rechts der Isar, Technische Universitaet Muenchen (TUM), Department of Radiation Oncology, Munich (Germany); Durante, Marco [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); Technische Universitaet Darmstadt, Faculty of Physics, Darmstadt (Germany); Herfarth, Klaus [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Bert, Christoph [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); University Clinic Erlangen and Friedrich- Alexander-University Erlangen-Nuernberg (FAU), Department of Radiation Oncology, Erlangen (Germany); University Hospital Erlangen, Radiation Oncology, Erlangen (Germany)

    2016-02-15

    Intensity-modulated particle therapy (IMPT) for tumors showing interfraction motion is a topic of current research. The purpose of this work is to compare three treatment strategies for IMPT to determine potential advantages and disadvantages of ion prostate cancer therapy. Simulations for three treatment strategies, conventional one-plan radiotherapy (ConvRT), image-guided radiotherapy (IGRT), and online adaptive radiotherapy (ART) were performed employing a dataset of 10 prostate cancer patients with six CT scans taken at one week intervals. The simulation results, using a geometric margin concept (7-2 mm) as well as patient-specific internal target volume definitions for IMPT were analyzed by target coverage and exposure of critical structures on single fraction dose distributions. All strategies led to clinically acceptable target coverage in patients exhibiting small prostate motion (mean displacement < 4 mm), but IGRT and especially ART led to significant sparing of the rectum. In 20 % of the patients, prostate motion exceeded 4 mm causing insufficient target coverage for ConvRT (V95{sub mean} = 0.86, range 0.63-0.99) and IGRT (V95{sub mean} = 0.91, range 0.68-1.00), while ART maintained acceptable target coverage. IMPT of prostate cancer demands consideration of rectal sparing and adaptive treatment replanning for patients exhibiting large prostate motion. (orig.) [German] Adaptive Therapieansaetze fuer sich interfraktionell bewegende Zielvolumina in der intensitaetsmodulierten Partikeltherapie (IMPT) befinden sich zurzeit in der Entwicklung. In dieser Arbeit werden drei Behandlungsstrategien auf moegliche Vor- und Nachteile in der IMPT des Prostatakarzinoms hin untersucht. Auf Basis eines anonymisierten Datensatzes aus 10 Patienten mit Prostatakarzinom wurden die drei Bestrahlungsstrategien, konventionelle Ein-Plan-Strahlentherapie (ConvRT), bildunterstuetzte Strahlentherapie (IGRT) und tagesaktuelle Strahlentherapie (adaptive radiotherapy,ART), simuliert

  2. Adaptive-backstepping force/motion control for mobile-manipulator robot based on fuzzy CMAC neural networks

    Institute of Scientific and Technical Information of China (English)

    Thang-Long MAI; Yaonan WANG

    2014-01-01

    In this paper, an adaptive backstepping fuzzy cerebellar-model-articulation-control neural-networks control (ABFCNC) system for motion/force control of the mobile-manipulator robot (MMR) is proposed. By applying the ABFCNC in the tracking-position controller, the unknown dynamics and parameter variation problems of the MMR control system are relaxed. In addition, an adaptive robust compensator is proposed to eliminate uncertainties that consist of approximation errors, uncertain disturbances. Based on the tracking position-ABFCNC design, an adaptive robust control strategy is also developed for the nonholonomic-constraint force of the MMR. The design of adaptive-online learning algorithms is obtained by using the Lyapunov stability theorem. Therefore, the proposed method proves that it not only can guarantee the stability and robustness but also the tracking performances of the MMR control system. The effectiveness and robustness of the proposed control system are verified by comparative simulation results.

  3. In vitro evaluation of photon and raster-scanned carbon ion radiotherapy in combination with gemcitabine in pancreatic cancer cell lines

    International Nuclear Information System (INIS)

    Pancreatic cancer is the fourth leading cause of cancer deaths, being responsible for 6% of all cancer-related deaths. Conventional radiotherapy with or without additional chemotherapy has been applied in the past in the context of neoadjuvant or adjuvant therapy concepts with only modest results, however new radiation modalities, such as particle therapy with promising physical and biological characteristics, present an alternative treatment option for patients with pancreatic cancer. Up until now the raster scanning technique employed at our institution for the application of carbon ions has been unique, and no radiobiological data using pancreatic cancer cells has been available yet. The aim of this study was to evaluate cytotoxic effects that can be achieved by treating pancreatic cancer cell lines with combinations of X-rays and gemcitabine, or alternatively with carbon ion irradiation and gemcitabine, respectively. Human pancreatic cancer cell lines AsPC-1, BxPC-3 and Panc-1 were irradiated with photons and carbon ions at various doses and treated with gemcitabine. Photon irradiation was applied with a biological cabin X-ray irradiator, and carbon ion irradiation was applied with an extended Bragg peak (linear energy transfer (LET) 103 keV/μm) using the raster scanning technique at the Heidelberg Ion Therapy Center (HIT). Responsiveness of pancreatic cancer cells to the treatment was measured by clonogenic survival. Clonogenic survival curves were then compared to predicted curves that were calculated employing the local effect model (LEM). Cell survival curves were calculated from the surviving fractions of each combination experiment and compared to a drug control that was only irradiated with X-rays or carbon ions, without application of gemcitabine. In terms of cytotoxicity, additive effects were achieved for the cell lines Panc-1 and BxPC-3, and a slight radiosensitizing effect was observed for AsPC-1. Relative biological effectiveness (RBE) of carbon

  4. Optimization of carbon ion and proton treatment plans using the raster-scanning technique for patients with unresectable pancreatic cancer

    International Nuclear Information System (INIS)

    The aim of the thesis is to improve radiation plans of patients with locally advanced, unresectable pancreatic cancer by using carbon ion and proton beams. Using the treatment planning system Syngo RT Planning (Siemens, Erlangen, Germany) a total of 50 treatment plans have been created for five patients with the dose schedule 15 × 3 Gy(RBE). With reference to the anatomy, five field configurations were considered to be relevant. The plans were analyzed with respect to dose distribution and individual anatomy, and compared using a customized index. Within the index the three-field configurations yielded the best results, though with a high variety of score points (field setup 5, carbon ion: median 74 (range 48–101)). The maximum dose in the myelon is low (e.g. case 3, carbon ion: 21.5 Gy(RBE)). A single posterior field generally spares the organs at risk, but the maximum dose in the myelon is high (e.g. case 3, carbon ion: 32.9 Gy(RBE)). Two oblique posterior fields resulted in acceptable maximum doses in the myelon (e.g. case 3, carbon ion: 26.9 Gy(RBE)). The single-field configuration and the two oblique posterior fields had a small score dispersion (carbon ion: median 66 and 58 (range 62–72 and 40–69)). In cases with topographic proximity of the organs at risk to the target volume, the single-field configuration scored as well as the three-field configurations. In summary, the three-field configurations showed the best dose distributions. A single posterior field seems to be robust and beneficial in case of difficult topographical conditions and topographical proximity of organs at risk to the target volume. A setup with two oblique posterior fields is a reasonable compromise between three-field and single-field configurations

  5. Raster-scanned carbon ion therapy for malignant salivary gland tumors: acute toxicity and initial treatment response

    International Nuclear Information System (INIS)

    To investigate toxicity and efficacy in high-risk malignant salivary gland tumors (MSGT) of the head and neck. Local control in R2-resected adenoid cystic carcinoma was already improved with a combination of IMRT and carbon ion boost at only mild side-effects, hence this treatment was also offered to patients with MSGT and microscopic residual disease (R1) or perineural spread (Pn+). From November 2009, all patients with MSGT treated with carbon ion therapy were evaluated. Acute side effects were scored according to CTCAE v.4.03. Tumor response was assessed according to RECIST where applicable. 103 patients were treated from 11/2009 to 03/2011, median follow-up is 6 months. 60 pts received treatment following R2 resections or as definitive radiation, 43 patients received adjuvant radiation for R1 and/or Pn+. 16 patients received carbon ion treatment for re-irradiation. Median total dose was 73.2 GyE (23.9 GyE carbon ions + 49,9 Gy IMRT) for primary treatment and 44.9 GyE carbon ions for re-irradiation. All treatments were completed as planned and generally well tolerated with no > CTC°III toxicity. Rates of CTC°III toxicity (mucositis and dysphagia) were 8.7% with side-effects almost completely resolved at first follow-up. 47 patients showed good treatment responses (CR/PR) according to RECIST. Acute toxicity remains low in IMRT with carbon ion boost also in R1-resected patients and patients undergoing re-irradiation. R2-resected patients showed high rates of treatment response, though follow-up is too short to assess long-term disease control

  6. Study of corrosion inhibition of coupled Al2Cu–Al and Al3Fe–Al by cerium cinnamate using scanning vibrating electrode technique and scanning ion-selective electrode technique

    International Nuclear Information System (INIS)

    Highlights: • The corrosion inhibition of coupled Al2Cu–Al and Al3Fe–Al by cerium cinnamate was studied. • SVET and SIET were used to study the distribution of current densities and pH. • The corrosion inhibition mechanisms were analyzed. - Abstract: The galvanic corrosion of the coupled Al2Cu and Al as well as Al3Fe and Al in 0.005 M NaCl in and without the presence of cerium cinnamate was studied. Scanning vibrating electrode technique and scanning ion-selective electrode technique were used to measure the distribution of current densities and pH. The results indicate that cerium cinnamate played inhibiting effect on the coupling corrosion of Al2Cu–Al and Al3Fe–Al. For Al2Cu–Al, the inhibition was mainly influenced by the production of cerium oxide/hydroxide on Al2Cu surface. However, for Al3Fe–Al, the inhibition was mainly influenced by the adsorbed cerium cinnamate on the Al3Fe surface

  7. Development of digital reconstructed radiography software at new treatment facility for carbon-ion beam scanning of National Institute of Radiological Sciences

    International Nuclear Information System (INIS)

    To increase the accuracy of carbon ion beam scanning therapy, we have developed a graphical user interface-based digitally-reconstructed radiograph (DRR) software system for use in routine clinical practice at our center. The DRR software is used in particular scenarios in the new treatment facility to achieve the same level of geometrical accuracy at the treatment as at the imaging session. DRR calculation is implemented simply as the summation of CT image voxel values along the X-ray projection ray. Since we implemented graphics processing unit-based computation, the DRR images are calculated with a speed sufficient for the particular clinical practice requirements. Since high spatial resolution flat panel detector (FPD) images should be registered to the reference DRR images in patient setup process in any scenarios, the DRR images also needs higher spatial resolution close to that of FPD images. To overcome the limitation of the CT spatial resolution imposed by the CT voxel size, we applied image processing to improve the calculated DRR spatial resolution. The DRR software introduced here enabled patient positioning with sufficient accuracy for the implementation of carbon-ion beam scanning therapy at our center.

  8. Design of block backstepping controllers for a class of perturbed multiple inputs and state-delayed systems in semi-strict-feedback form

    Science.gov (United States)

    Lin, Yan-Si; Cheng, Chih-Chiang

    2016-04-01

    Based on the Lyapunov stability theorem, an adaptive block backstepping control scheme is proposed in this paper for a class of multi-input systems with mismatched multiple state-delayed perturbations to solve regulation problems. The traditional backstepping control method is modified so that it can be directly applied to systems in block semi-strict-feedback form. The terms in the dynamic equations which do not satisfy the block strict-feedback form are accumulated in the last design step and are suppressed effectively by the adaptive gains, so that the property of asymptotic stability is achieved. Adaptive mechanisms are employed in each of the virtual input controllers as well as the robust controller, hence the least upper bounds of perturbations are not required to be known in advance. A numerical example and a practical application are also given for demonstrating the feasibility of the proposed control scheme.

  9. Global Harmonic Current Rejection of Nonlinear Backstepping Control with Multivariable Adaptive Internal Model Principle for Grid-Connected Inverter under Distorted Grid Voltage

    Directory of Open Access Journals (Sweden)

    Yang Yu

    2013-01-01

    Full Text Available Based on a brief review on current harmonics generation mechanism for grid-connected inverter under distorted grid voltage, the harmonic disturbances and uncertain items are immersed into the original state-space differential equation of grid-connected inverter. A new algorithm of global current harmonic rejection based on nonlinear backstepping control with multivariable internal model principle is proposed for grid-connected inverter with exogenous disturbances and uncertainties. A type of multivariable internal model for a class of nonlinear harmonic disturbances is constructed. Based on application of backstepping control law of the nominal system, a multivariable adaptive state feedback controller combined with multivariable internal model and adaptive control law is designed to guarantee the closed-loop system globally uniformly bounded, which is proved by a constructed Lyapunov function. The presented algorithm extends rejection of nonlinear single-input systems to multivariable globally defined normal form, the correctness and effectiveness of which are verified by the simulation results.

  10. Comparison of backstepping and modified active control in projective synchronization of chaos in an extended Bonhöffer–van der Pol oscillator

    Indian Academy of Sciences (India)

    K S Ojo; A N Njah; S T Ogunjo

    2013-05-01

    In this article, projective synchronization of double–scroll attractor of an extended Bonöffer–van der Pol oscillator (BVPO) is considered via the backstepping and active control techniques. In each synchronization scheme, a single control function is designed to achieve projective synchronization between two Bonhöffer–van der Pol oscillator evolving from different initial conditions. To obtain a single control function via the active control, the coefficient of the error dynamics is chosen such that the number of control functions is reduced from three to one, thereby, reducing control function complexity in design. The results show that the transient error dynamics convergence and synchronization time are achieved faster via the backstepping than that of the active control technique. However, the control function obtained via the active control is simpler with a more stable synchronization time and hence, it is more suitable for practical implementation. Numerical simulations are presented to confirm the effectiveness of the analytical results.

  11. Application of Backstepping to the Virtual Flux Direct Power Control of Five-Level Three-Phase Shunt Active Power Filter

    Directory of Open Access Journals (Sweden)

    Bouzidi Mansour

    2014-03-01

    Full Text Available This paper proposes a virtual flux direct power control-space vector modulation combined with backstepping control for three-phase five-level neutral point clamped shunt active power filter. The main goal of the proposed active filtering system is to eliminate the unwanted harmonics and compensate fundamental reactive power drawn from the nonlinear loads. In this study, the voltage-balancing control of four split dc capacitors of the five-level active filter is achieved using five-level space vector modulation with balancing strategy based on the effective use of the redundant switching states of the inverter voltage vectors. The obtained results showed that, the proposed multilevel shunt active power filter with backstepping control can produce a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.

  12. The relative biological effectiveness for carbon and oxygen ion beams using the raster-scanning technique in hepatocellular carcinoma cell lines.

    Directory of Open Access Journals (Sweden)

    Daniel Habermehl

    Full Text Available BACKGROUND: Aim of this study was to evaluate the relative biological effectiveness (RBE of carbon (12C and oxygen ion (16O-irradiation applied in the raster-scanning technique at the Heidelberg Ion beam Therapy center (HIT based on clonogenic survival in hepatocellular carcinoma cell lines compared to photon irradiation. METHODS: Four human HCC lines Hep3B, PLC, HepG2 and HUH7 were irradiated with photons, 12C and 16O using a customized experimental setting at HIT for in-vitro trials. Cells were irradiated with increasing physical photon single doses of 0, 2, 4 and 6 Gy and heavy ion-single doses of 0, 0.125, 0.5, 1, 2, 3 Gy (12C and 16O. SOBP-penetration depth and extension was 35 mm +/-4 mm and 36 mm +/-5 mm for carbon ions and oxygen ions respectively. Mean energy level and mean linear energy transfer (LET were 130 MeV/u and 112 keV/um for 12C, and 154 MeV/u and 146 keV/um for 16O. Clonogenic survival was computated and relative biological effectiveness (RBE values were defined. RESULTS: For all cell lines and both particle modalities α- and β-values were determined. As expected, α-values were significantly higher for 12C and 16O than for photons, reflecting a steeper decline of the initial slope of the survival curves for high-LET beams. RBE-values were in the range of 2.1-3.3 and 1.9-3.1 for 12C and 16O, respectively. CONCLUSION: Both irradiation with 12C and 16O using the raster-scanning technique leads to an enhanced RBE in HCC cell lines. No relevant differences between achieved RBE-values for 12C and 16O were found. Results of this work will further influence biological-adapted treatment planning for HCC patients that will undergo particle therapy with 12C or 16O.

  13. Carbon-Based Solid-State Calcium Ion-Selective Microelectrode and Scanning Electrochemical Microscopy: A Quantitative Study of pH-Dependent Release of Calcium Ions from Bioactive Glass.

    Science.gov (United States)

    Ummadi, Jyothir Ganesh; Downs, Corey J; Joshi, Vrushali S; Ferracane, Jack L; Koley, Dipankar

    2016-03-15

    Solid-state ion-selective electrodes are used as scanning electrochemical microscope (SECM) probes because of their inherent fast response time and ease of miniaturization. In this study, we report the development of a solid-state, low-poly(vinyl chloride), carbon-based calcium ion-selective microelectrode (Ca(2+)-ISME), 25 μm in diameter, capable of performing an amperometric approach curve and serving as a potentiometric sensor. The Ca(2+)-ISME has a broad linear response range of 5 μM to 200 mM with a near Nernstian slope of 28 mV/log[a(Ca(2+))]. The calculated detection limit for Ca(2+)-ISME is 1 μM. The selectivity coefficients of this Ca(2+)-ISME are log K(Ca(2+),A) = -5.88, -5.54, and -6.31 for Mg(2+), Na(+), and K(+), respectively. We used this new type of Ca(2+)-ISME as an SECM probe to quantitatively map the chemical microenvironment produced by a model substrate, bioactive glass (BAG). In acidic conditions (pH 4.5), BAG was found to increase the calcium ion concentration from 0.7 mM ([Ca(2+)] in artificial saliva) to 1.4 mM at 20 μm above the surface. In addition, a solid-state dual SECM pH probe was used to correlate the release of calcium ions with the change in local pH. Three-dimensional pH and calcium ion distribution mapping were also obtained by using these solid-state probes. The quantitative mapping of pH and Ca(2+) above the BAG elucidates the effectiveness of BAG in neutralizing and releasing calcium ions in acidic conditions. PMID:26861499

  14. Proton and carbon ion radiotherapy for primary brain tumors delivered with active raster scanning at the Heidelberg Ion Therapy Center (HIT): early treatment results and study concepts

    International Nuclear Information System (INIS)

    Particle irradiation was established at the University of Heidelberg 2 years ago. To date, more than 400 patients have been treated including patients with primary brain tumors. In malignant glioma (WHO IV) patients, two clinical trials have been set up-one investigating the benefit of a carbon ion (18 GyE) vs. a proton boost (10 GyE) in addition to photon radiotherapy (50 Gy), the other one investigating reirradiation with escalating total dose schedules starting at 30 GyE. In atypical meningioma patients (WHO °II), a carbon ion boost of 18 GyE is applied to macroscopic tumor residues following previous photon irradiation with 50 Gy. This study was set up in order to investigate toxicity and response after proton and carbon ion therapy for gliomas and meningiomas. 33 patients with gliomas (n = 26) and meningiomas (n = 7) were treated with carbon ion (n = 26) and proton (n = 7) radiotherapy. In 22 patients, particle irradiation was combined with photon therapy. Temozolomide-based chemotherapy was combined with particle therapy in 17 patients with gliomas. Particle therapy as reirradiation was conducted in 7 patients. Target volume definition was based upon CT, MRI and PET imaging. Response was assessed by MRI examinations, and progression was diagnosed according to the Macdonald criteria. Toxicity was classified according to CTCAE v4.0. Treatment was completed and tolerated well in all patients. Toxicity was moderate and included fatigue (24.2%), intermittent cranial nerve symptoms (6%) and single episodes of seizures (6%). At first and second follow-up examinations, mean maximum tumor diameters had slightly decreased from 29.7 mm to 27.1 mm and 24.9 mm respectively. Nine glioma patients suffered from tumor relapse, among these 5 with infield relapses, causing death in 8 patients. There was no progression in any meningioma patient. Particle radiotherapy is safe and feasible in patients with primary brain tumors. It is associated with little toxicity. A positive

  15. Proton and carbon ion radiotherapy for primary brain tumors delivered with active raster scanning at the Heidelberg Ion Therapy Center (HIT: early treatment results and study concepts

    Directory of Open Access Journals (Sweden)

    Rieken Stefan

    2012-03-01

    Full Text Available Abstract Background Particle irradiation was established at the University of Heidelberg 2 years ago. To date, more than 400 patients have been treated including patients with primary brain tumors. In malignant glioma (WHO IV patients, two clinical trials have been set up-one investigating the benefit of a carbon ion (18 GyE vs. a proton boost (10 GyE in addition to photon radiotherapy (50 Gy, the other one investigating reirradiation with escalating total dose schedules starting at 30 GyE. In atypical meningioma patients (WHO °II, a carbon ion boost of 18 GyE is applied to macroscopic tumor residues following previous photon irradiation with 50 Gy. This study was set up in order to investigate toxicity and response after proton and carbon ion therapy for gliomas and meningiomas. Methods 33 patients with gliomas (n = 26 and meningiomas (n = 7 were treated with carbon ion (n = 26 and proton (n = 7 radiotherapy. In 22 patients, particle irradiation was combined with photon therapy. Temozolomide-based chemotherapy was combined with particle therapy in 17 patients with gliomas. Particle therapy as reirradiation was conducted in 7 patients. Target volume definition was based upon CT, MRI and PET imaging. Response was assessed by MRI examinations, and progression was diagnosed according to the Macdonald criteria. Toxicity was classified according to CTCAE v4.0. Results Treatment was completed and tolerated well in all patients. Toxicity was moderate and included fatigue (24.2%, intermittent cranial nerve symptoms (6% and single episodes of seizures (6%. At first and second follow-up examinations, mean maximum tumor diameters had slightly decreased from 29.7 mm to 27.1 mm and 24.9 mm respectively. Nine glioma patients suffered from tumor relapse, among these 5 with infield relapses, causing death in 8 patients. There was no progression in any meningioma patient. Conclusions Particle radiotherapy is safe and feasible in patients with primary brain

  16. Three-dimensional investigation of cycling-induced microstructural changes in lithium-ion battery cathodes using focused ion beam/scanning electron microscopy

    Science.gov (United States)

    Liu, Hanshuo; Foster, Jamie M.; Gully, Adam; Krachkovskiy, Sergey; Jiang, Meng; Wu, Yan; Yang, Xingyi; Protas, Bartosz; Goward, Gillian R.; Botton, Gianluigi A.

    2016-02-01

    For vehicle electrification, one of the biggest issues for lithium ion batteries is cycle life. Within this context, the mechanisms at the source of capacity degradation during cycling are not yet to be fully understood. In this work, we use state-of-the-art FIB-SEM serial sectioning and imaging techniques to determine the effect of cycling on lithium-ion battery cathodes. The three-dimensional (3D) microstructural study was performed on both pristine and cycled LiNixMnyCo1-x-yO2 (NMC) and Li(Li0.2Ni0.13Mn0.54Co0.13)O2 (HE-NMC) cathodes. The spatial distribution of active material, carbon-doped binder and pore spaces were successfully reconstructed by appropriate image processing. Comparisons of NMC and HE-NMC cathodes after different number of cycles showed only minor increases in the number of smaller active particles, possibly negligible, considering the intrinsic microstructure variation within the cathodes. However, the connectivity between carbon-doped binder additives and active particles in NMC and HE-NMC cathodes, assessed using a "neighbor counting" method, showed an appreciable decrease after cycling which indicates a detachment of carbon-doped binder from active particles. This significant cycling-induced detachment effect between the two phases (e.g., ∼22% for HE-NMC) could indicate a loss in electrical connectivity, which may partially explain the capacity fade in the cells.

  17. Argon broad ion beam tomography in a cryogenic scanning electron microscope: a novel tool for the investigation of representative microstructures in sedimentary rocks containing pore fluid.

    Science.gov (United States)

    Desbois, G; Urai, J L; Pérez-Willard, F; Radi, Z; Offern, S; Burkart, I; Kukla, P A; Wollenberg, U

    2013-03-01

    The contribution describes the implementation of a broad ion beam (BIB) polisher into a scanning electron microscope (SEM) functioning at cryogenic temperature (cryo). The whole system (BIB-cryo-SEM) provides a first generation of a novel multibeam electron microscope that combines broad ion beam with cryogenic facilities in a conventional SEM to produce large, high-quality cross-sections (up to 2 mm(2)) at cryogenic temperature to be imaged at the state-of-the-art SEM resolution. Cryogenic method allows detecting fluids in their natural environment and preserves samples against desiccation and dehydration, which may damage natural microstructures. The investigation of microstructures in the third dimension is enabled by serial cross-sectioning, providing broad ion beam tomography with slices down to 350 nm thick. The functionalities of the BIB-cryo-SEM are demonstrated by the investigation of rock salts (synthetic coarse-grained sodium chloride synthesized from halite-brine mush cold pressed at 150 MPa and 4.5 GPa, and natural rock salt mylonite from a salt glacier at Qom Kuh, central Iran). In addition, results from BIB-cryo-SEM on a gas shale and Boom Clay are also presented to show that the instrument is suitable for a large range of sedimentary rocks. For the first time, pore and grain fabrics of preserved host and reservoir rocks can be investigated at nm-scale range over a representative elementary area. In comparison with the complementary and overlapping performances of the BIB-SEM method with focused ion beam-SEM and X-ray tomography methods, the BIB cross-sectioning enables detailed insights about morphologies of pores at greater resolution than X-ray tomography and allows the production of large representative surfaces suitable for FIB-SEM investigations of a specific representative site within the BIB cross-section. PMID:23323728

  18. Qualitative and Quantitative Characterization of Porosity in a Low Porous and Low Permeable Organic Rich Shale by Combining Broad Ion Beam and Scanning Electron Microscopy (BIB-SEM)

    International Nuclear Information System (INIS)

    This contribution focuses on the characterization of porosity in low porous shale using a broad ion beam (BIB) polishing technique combined with a conventional scanning electron microscopy (SEM). Porosity was traced in certain representative elementary areas (REA) and pores detected are segmented from mosaics of secondary electron (SE) images. Traced pores could be classified into two major pore-size classes. Relative large pores (> 0.5 μm2) were found in the organic matter and matrix. They contribute strongly to the overall porosity con-tent of the shale. Nevertheless the far majority of the pores traced have equivalent radius less than 400 nm. Including the latter pore class, the imaged porosity from both samples gives similar results in the order of < 1 %. (authors)

  19. Back-stepping active disturbance rejection control design for integrated missile guidance and control system via reduced-order ESO.

    Science.gov (United States)

    Xingling, Shao; Honglun, Wang

    2015-07-01

    This paper proposes a novel composite integrated guidance and control (IGC) law for missile intercepting against unknown maneuvering target with multiple uncertainties and control constraint. First, by using back-stepping technique, the proposed IGC law design is separated into guidance loop and control loop. The unknown target maneuvers and variations of aerodynamics parameters in guidance and control loop are viewed as uncertainties, which are estimated and compensated by designed model-assisted reduced-order extended state observer (ESO). Second, based on the principle of active disturbance rejection control (ADRC), enhanced feedback linearization (FL) based control law is implemented for the IGC model using the estimates generated by reduced-order ESO. In addition, performance analysis and comparisons between ESO and reduced-order ESO are examined. Nonlinear tracking differentiator is employed to construct the derivative of virtual control command in the control loop. Third, the closed-loop stability for the considered system is established. Finally, the effectiveness of the proposed IGC law in enhanced interception performance such as smooth interception course, improved robustness against multiple uncertainties as well as reduced control consumption during initial phase are demonstrated through simulations. PMID:25776190

  20. Impact of electrolyte composition on the reactivity of a redox active polymer studied through surface interrogation and ion-sensitive scanning electrochemical microscopy.

    Science.gov (United States)

    Burgess, Mark; Hernández-Burgos, Kenneth; Cheng, Kevin J; Moore, Jeffrey S; Rodríguez-López, Joaquín

    2016-06-21

    Elucidating the impact of interactions between the electrolyte and electroactive species in redox active polymers is key to designing better-performing electrodes for electrochemical energy storage and conversion. Here, we present on the improvement of the electrochemical activity of poly(para-nitrostyrene) (PNS) in solution and as a film by exploiting the ionic interactions between reduced PNS and K(+), which showed increased reactivity when compared to tetrabutylammonium (TBA(+))- and Li(+)-containing electrolytes. While cyclic voltammetry enabled the study of the effects of cations on the electrochemical reversibility and the reduction potential of PNS, scanning electrochemical microscopy (SECM) provided new tools to probe the ionic and redox reactivity of this system. Using an ion-sensitive Hg SECM tip allowed to probe the ingress of ions into PNS redox active films, while surface interrogation SECM (SI-SECM) measured the specific kinetics of PNS and a solution phase mediator in the presence of the tested electrolytes. SI-SECM measurements illustrated that the interrogation kinetics of PNS in the presence of K(+) compared to TBA(+) and Li(+) are greatly enhanced under the same surface concentration of adsorbed radical anion, exhibiting up to a 40-fold change in redox kinetics. We foresee using this new application of SECM methods for elucidating optimal interactions that enhance polymer reactivity for applications in redox flow batteries. PMID:27064026

  1. Atomistic structure of a spinel Li4Ti5O12(111) surface elucidated by scanning tunneling microscopy and medium energy ion scattering spectrometry

    Science.gov (United States)

    Kitta, Mitsunori; Matsuda, Taishi; Maeda, Yasushi; Akita, Tomoki; Tanaka, Shingo; Kido, Yoshiaki; Kohyama, Masanori

    2014-01-01

    Spinel lithium titanate (Li4Ti5O12, LTO) is one of the promising anode materials for high-performance lithium-ion batteries (LIBs). It is crucial to investigate atomistic structures of LTO surfaces to understand the phenomena at LTO/electrolyte interfaces such as CO2-gas generation which greatly affects the performance and safety of LIBs. By applying scanning tunneling microscopy (STM) and medium energy ion scattering spectrometry (MEIS) to a LTO(111) film prepared from a TiO2 wafer, we found that there exist two kinds of Li-terminated (111) terraces bounded by steps with different heights. In the major terraces, the top hexagonal Li layer is stacked above the oxygen layer, while the top Li layer is stacked above the Ti-Li layer in the minor terraces. The relative stability between the two surface structures seems to depend on the atmosphere due to different stoichiometry. For the major terraces, the LTO surface should have electronic holes due to oxygen-rich stoichiometry, which is a possible origin of CO2 generation via redox interaction with electrolyte molecules.

  2. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  3. Rapid screening and characterization of drug metabolites using multiple ion monitoring dependent product ion scan and postacquisition data mining on a hybrid triple quadrupole-linear ion trap mass spectrometer.

    Science.gov (United States)

    Yao, Ming; Ma, Li; Duchoslav, Eva; Zhu, Mingshe

    2009-06-01

    Multiple ion monitoring (MIM)-dependent acquisition with a triple quadrupole-linear ion trap mass spectrometer (Q-trap) was previously developed for drug metabolite profiling. In the analysis, multiple predicted metabolite ions are monitored in both Q1 and Q3 regardless of their fragmentations. The collision energy in Q2 is set to a low value to minimize fragmentation. Once an expected metabolite is detected by MIM, enhanced product ion (EPI) spectral acquisition of the metabolite is triggered. To analyze in vitro metabolites, MIM-EPI retains the sensitivity and selectivity similar to that of multiple reaction monitoring (MRM)-EPI in the analysis of in vitro metabolites. Here we present an improved approach utilizing MIM-EPI for data acquisition and multiple data mining techniques for detection of metabolite ions and recovery of their MS/MS spectra. The postacquisition data processing tools included extracted ion chromatographic analysis, product ion filtering and neutral loss filtering. The effectiveness of this approach was evaluated by analyzing oxidative metabolites of indinavir and glutathione (GSH) conjugates of clozapine and 4-ethylphenol in liver microsome incubations. Results showed that the MIM-EPI-based data mining approach allowed for comprehensive detection of metabolites based on predicted protonated molecules, product ions or neutral losses without predetermination of the parent drug MS/MS spectra. Additionally, it enabled metabolite detection and MS/MS acquisition in a single injection. This approach is potentially useful in high-throughout screening of metabolic soft spots and reactive metabolites at the drug discovery stage. PMID:19418486

  4. Complementary microanalysis of Zn, Mn and Fe in the chelicera of spiders and scorpions using scanning MeV-ion and electron microprobes

    International Nuclear Information System (INIS)

    Energy-loss scanning transmission ion microscopy (ELSTIM or just STIM), PIXE and electron microprobe techniques are used to investigate certain minor element accumulations in a few spiders and scorpions. STIM and PIXE are used to survey the unsectioned specimens, while electron microprobe techniques are used for higher resolution investigations of several sections of the specimens. Concentration values measured using STIM and PIXE are found to be in satisfactory agreement with those measured using electron probe microanalysis. A garden spider Araneous diadematus is found to contain high concentrations of zinc in a thin layer near the surface of its fangs (reaching 23% of dry weight), and manganese in its marginal teeth (about 5% of dry weight). A wolf spider Alopecosa kochi is found to have similar concentrations of zinc in a layer near the surface of it's fang, and concentrations of manganese reaching 1.5% in a layer beneath the zinc containing layer. A scorpion Centruroides sp. is found to contain high concentrations of iron (reaching 8%) and zinc (reaching 24%) in the tips of teeth on the cheliceral fingers, and manganese (about 5%) in the stinger. The hypothesis that these elements simply harden the cuticle does not appear to explain their segregation patterns. (orig.)

  5. Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis

    International Nuclear Information System (INIS)

    State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 μm in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program “SARINA,” which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

  6. Dynamic modeling of a hose-drogue aerial refueling system and integral sliding mode backstepping control for the hose whipping phenomenon

    Institute of Scientific and Technical Information of China (English)

    Wang Haitao; Dong Xinmin; Xue Jianping; Liu Jiaolong

    2014-01-01

    Dynamic modeling of a hose-drogue aerial refueling system (HDARS) and an integral sliding mode backstepping controller design for the hose whipping phenomenon (HWP) during probe-drogue coupling are studied. Firstly, a dynamic model of the variable-length hose-drogue assembly is built for the sake of exploiting suppression methods for the whipping phenomenon. Based on the lumped parameter method, the hose is modeled by a series of variable-length links connected with frictionless joints. A set of iterative equations of the hose’s three-dimensional motion is derived subject to hose reeling in/out, tanker motion, gravity, and aerodynamic loads accounting for the effects of steady wind, atmospheric turbulence, and tanker wake. Secondly, relying on a permanent magnet synchronous motor and high-precision position sensors, a new active control strategy for the HWP on the basis of the relative position between the tanker and the receiver is proposed. Considering the strict-feedback configuration of the permanent magnet synchronous motor, a rotor position control law based on the backstepping method is designed to insure global stability. An integral of the rotor position error and an exponential sliding mode reaching law of the current errors are applied to enhance control accuracy and robustness. Finally, the simulation results show the effectiveness of the proposed model and control laws.

  7. CT Scans

    Science.gov (United States)

    ... cross-sectional pictures of your body. Doctors use CT scans to look for Broken bones Cancers Blood clots Signs of heart disease Internal bleeding During a CT scan, you lie still on a table. The table ...

  8. Thyroid scan

    Science.gov (United States)

    ... PET scan Skin nodules Thyroid cancer Thyroid cancer - medullary carcinoma Thyroid cancer - papillary carcinoma Toxic nodular goiter ... Topics Hyperthyroidism Hypothyroidism Nuclear Scans Thyroid Cancer Thyroid Diseases Thyroid Tests Browse the Encyclopedia A.D.A. ...

  9. Carbon-ion scanning lung treatment planning with respiratory-gated phase-controlled rescanning: simulation study using 4-dimensional CT data

    International Nuclear Information System (INIS)

    To moving lung tumors, we applied a respiratory-gated strategy to carbon-ion pencil beam scanning with multiple phase-controlled rescanning (PCR). In this simulation study, we quantitatively evaluated dose distributions based on 4-dimensional CT (4DCT) treatment planning. Volumetric 4DCTs were acquired for 14 patients with lung tumors. Gross tumor volume, clinical target volume (CTV) and organs at risk (OARs) were delineated. Field-specific target volumes (FTVs) were calculated, and 48Gy(RBE) in a single fraction was prescribed to the FTVs delivered from four beam angles. The dose assessment metrics were quantified by changing the number of PCR and the results for the ungated and gated scenarios were then compared. For the ungated strategy, the mean dose delivered to 95% of the volume of the CTV (CTV-D95) was in average 45.3 ± 0.9 Gy(RBE) even with a single rescanning (1 × PCR). Using 4 × PCR or more achieved adequate target coverage (CTV-D95 = 46.6 ± 0.3 Gy(RBE) for ungated 4 × PCR) and excellent dose homogeneity (homogeneity index =1.0 ± 0.2% for ungated 4 × PCR). Applying respiratory gating, percentage of lung receiving at least 20 Gy(RBE) (lung-V20) and heart maximal dose, averaged over all patients, significantly decreased by 12% (p < 0.05) and 13% (p < 0.05), respectively. Four or more PCR during PBS-CIRT improved dose conformation to moving lung tumors without gating. The use of a respiratory-gated strategy in combination with PCR reduced excessive doses to OARs

  10. Characterization of stainless steel through Scanning Electron Microscopy, nitrided in the process of implantation of immersed ions in plasma; Caracterizacion de acero inoxidable mediante Microscopia Electronica de Barrido nitrurado en el proceso de implantacion de iones inmersos en plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Moreno S, H

    2003-07-01

    The present project carries out the investigation of the nitridation of the austenitic stainless steel schedule 304, applying the novel technology of installation of nitrogen ions in immersed materials in plasma (Plll), by means of which they modify those properties of the surface of the steel. The obtained results by means of tests of Vickers microhardness, shows that the hardness was increment from 266 to 740 HV (microhardness units). It was determined by means of scanning electron microscopy, the one semiquantitative chemical analysis of the elements that constitute the austenitic stainless steel schedule 304; the obtained results, show to the nitrogen like an element of their composition in the pieces where carried out to end the PIII technology. The parameters of the plasma with which carried out the technology Plll, were monitored and determined by means of electric probes, and with which it was determined that the density of particles is stable in the interval of 1x10{sup -1} at 3x10{sup -1}Torr, and it is where better results of hardness were obtained. That reported in this work, they are the first results obtained when applying the technology Plll in Mexico, and with base in these, it is even necessary to investigate and to deepen until to dominate the process and to be in possibilities of proposing it to be carried out and exploited in an industrial way. (Author)

  11. SU-C-303-06: Treatment Planning Study for Non-Invasive Cardiac Arrhythmia Ablation with Scanned Carbon Ions in An Animal Model

    Energy Technology Data Exchange (ETDEWEB)

    Eichhorn, A; Constantinescu, A; Prall, M; Kaderka, R; Durante, M; Graeff, C [GSI Helmholtz Center, Darmstadt, DE (Germany); Lehmann, H I; Takami, M; Packer, D L [Mayo Clinic, Rochester, Minnesota (United States); Lugenbiel, P; Thomas, D [University of Heidelberg, Heidelberg, DE (Germany); Richter, D; Bert, C [University Clinic Erlangen, Erlagen, DE (Germany)

    2015-06-15

    Purpose: Scanned carbon ion beams might offer a non-invasive alternative treatment for cardiac arrhythmia, which are a major health-burden. We studied the feasibility of this procedure in an animal model. The underlying treatment planning and motion mitigation strategies will be presented. Methods: The study was carried out in 15 pigs, randomly distributed to 3 target groups: atrioventricular node (AVN, 8 animals with 25, 40, and 55 Gy target dose), left ventricular free-wall (LV, 4 animals with 40 Gy) and superior pulmonary vein (SPV, 3 animals with 40 Gy). Breathing motion was suppressed by repeated enforced breathholds at end exhale. Cardiac motion was mitigated by an inhomogeneous rescanning scheme with up to 15 rescans. The treatment planning was performed using the GSI in-house software TRiP4D on cardiac-gated 4DCTs, applying a range-considering ITV based on an extended CTV. For AVN and SPV isotropic 5 mm margins were applied to the CTV, while for the LV 2mm+2% range margins were used. The opposing fields for AVN and LV targets were optimized independently (SFUD), while SPV treatments were optimized as IMPT deliveries, including dose restrictions to the radiosensitive AVN. Results: Median value of D{sub 95} over all rescanning simulations was 99.1% (AVN), 98.0% (SPV) and 98.3% (LV) for the CTV and 94.7% (AVN) and 92.7% (SPV) for the PTV, respectively. The median D{sub 5}-D{sub 95} was improved with rescanning compared to unmitigated delivery from 13.3 to 6.5% (CTV) and from 23.4 to 11.6% (PTV). ICRP dose limits for aorta, trachea, esophagus and skin were respected. The maximal dose in the coronary arteries was limited to 30 Gy. Conclusion: We demonstrated the feasibility of a homogeneous dose delivery to different cardiac structures in a porcine model using a time-optimized inhomogeneous rescanning scheme. The presented treatment planning strategies were applied in a pig study with the analysis ongoing. Funding: This work was supported in part by the

  12. SU-C-303-06: Treatment Planning Study for Non-Invasive Cardiac Arrhythmia Ablation with Scanned Carbon Ions in An Animal Model

    International Nuclear Information System (INIS)

    Purpose: Scanned carbon ion beams might offer a non-invasive alternative treatment for cardiac arrhythmia, which are a major health-burden. We studied the feasibility of this procedure in an animal model. The underlying treatment planning and motion mitigation strategies will be presented. Methods: The study was carried out in 15 pigs, randomly distributed to 3 target groups: atrioventricular node (AVN, 8 animals with 25, 40, and 55 Gy target dose), left ventricular free-wall (LV, 4 animals with 40 Gy) and superior pulmonary vein (SPV, 3 animals with 40 Gy). Breathing motion was suppressed by repeated enforced breathholds at end exhale. Cardiac motion was mitigated by an inhomogeneous rescanning scheme with up to 15 rescans. The treatment planning was performed using the GSI in-house software TRiP4D on cardiac-gated 4DCTs, applying a range-considering ITV based on an extended CTV. For AVN and SPV isotropic 5 mm margins were applied to the CTV, while for the LV 2mm+2% range margins were used. The opposing fields for AVN and LV targets were optimized independently (SFUD), while SPV treatments were optimized as IMPT deliveries, including dose restrictions to the radiosensitive AVN. Results: Median value of D95 over all rescanning simulations was 99.1% (AVN), 98.0% (SPV) and 98.3% (LV) for the CTV and 94.7% (AVN) and 92.7% (SPV) for the PTV, respectively. The median D5-D95 was improved with rescanning compared to unmitigated delivery from 13.3 to 6.5% (CTV) and from 23.4 to 11.6% (PTV). ICRP dose limits for aorta, trachea, esophagus and skin were respected. The maximal dose in the coronary arteries was limited to 30 Gy. Conclusion: We demonstrated the feasibility of a homogeneous dose delivery to different cardiac structures in a porcine model using a time-optimized inhomogeneous rescanning scheme. The presented treatment planning strategies were applied in a pig study with the analysis ongoing. Funding: This work was supported in part by the Helmholtz Association, the

  13. Adaptive sliding mode back-stepping pitch angle control of a variable-displacement pump controlled pitch system for wind turbines.

    Science.gov (United States)

    Yin, Xiu-xing; Lin, Yong-gang; Li, Wei; Liu, Hong-wei; Gu, Ya-jing

    2015-09-01

    A variable-displacement pump controlled pitch system is proposed to mitigate generator power and flap-wise load fluctuations for wind turbines. The pitch system mainly consists of a variable-displacement hydraulic pump, a fixed-displacement hydraulic motor and a gear set. The hydraulic motor can be accurately regulated by controlling the pump displacement and fluid flows to change the pitch angle through the gear set. The detailed mathematical representation and dynamic characteristics of the proposed pitch system are thoroughly analyzed. An adaptive sliding mode pump displacement controller and a back-stepping stroke piston controller are designed for the proposed pitch system such that the resulting pitch angle tracks its desired value regardless of external disturbances and uncertainties. The effectiveness and control efficiency of the proposed pitch system and controllers have been verified by using realistic dataset of a 750 kW research wind turbine. PMID:26303957

  14. CT scan

    Science.gov (United States)

    ... come from a CT scan. Some people have allergies to contrast dye. Let your doctor know if you have ... vein contains iodine. If you have an iodine allergy, a type of contrast may cause nausea or vomiting , sneezing , itching , or ...

  15. MRI Scans

    Science.gov (United States)

    Magnetic resonance imaging (MRI) uses a large magnet and radio waves to look at organs and structures inside your body. Health care professionals use MRI scans to diagnose a variety of conditions, from ...

  16. Energy Scan program

    Directory of Open Access Journals (Sweden)

    Poniatowska Katarzyna M.

    2014-04-01

    Full Text Available Femtoscopy of two non-identical particles in heavy ion collisions enables one to study the space-time asymmetry in the particle's emission process. Theoretical studies based on EPOS model performed for collision energies from the Beam Energy Scan program in STAR allow us to investigate the dependence of source sizes and dynamics effects. Obtained information will enable us to predict the collective behaviour of femtoscopic particle's source.

  17. Linking the microstructure, performance and durability of Ni-yttria-stabilized zirconia solid oxide fuel cell anodes using three-dimensional focused ion beam-scanning electron microscopy imaging

    International Nuclear Information System (INIS)

    In this work we demonstrate the utility of three-dimensional focused ion beam-scanning electron microscopy nanotomography for understanding composite electrode performance and degradation. Phase connectivity, electrochemically active triple-phase boundary density and phase tortuosity are calculated for a series of anodes with varying Ni-YSZ composition. These structural characteristics, achievable only through three-dimensional interrogation, are shown to play a vital role in determining electrode polarization resistance. Additionally, Ni-YSZ samples are experimentally annealed in hydrogen and reconstructed to quantitatively assess degradation as a function of reduced triple-phase boundary density.

  18. Scanning system

    International Nuclear Information System (INIS)

    An improved transversally cutting radionuclide scanning system is described which can be used for medical diagnosis and medical treatment of men, particularly, for brain investingations. 99mTc43 is named as a radionuclide. The device described is more sensitive, and displays results in a shorter period of time than devices known until now. By means of laser emitting diodes a continuous transmission and collection of signals is obtained, due to a rotating picture framework of offset and meshing detectors surrounding completely the scanning field around a single rotation axis - coaxialy with the axis of the head. Signals are processed and displayed by a connected computer. Description in detail, 7 figures. (UWI)

  19. A novel algorithm for the calculation of physical and biological irradiation quantities in scanned ion beam therapy: the beamlet superposition approach

    Science.gov (United States)

    Russo, G.; Attili, A.; Battistoni, G.; Bertrand, D.; Bourhaleb, F.; Cappucci, F.; Ciocca, M.; Mairani, A.; Milian, F. M.; Molinelli, S.; Morone, M. C.; Muraro, S.; Orts, T.; Patera, V.; Sala, P.; Schmitt, E.; Vivaldo, G.; Marchetto, F.

    2016-01-01

    The calculation algorithm of a modern treatment planning system for ion-beam radiotherapy should ideally be able to deal with different ion species (e.g. protons and carbon ions), to provide relative biological effectiveness (RBE) evaluations and to describe different beam lines. In this work we propose a new approach for ion irradiation outcomes computations, the beamlet superposition (BS) model, which satisfies these requirements. This model applies and extends the concepts of previous fluence-weighted pencil-beam algorithms to quantities of radiobiological interest other than dose, i.e. RBE- and LET-related quantities. It describes an ion beam through a beam-line specific, weighted superposition of universal beamlets. The universal physical and radiobiological irradiation effect of the beamlets on a representative set of water-like tissues is evaluated once, coupling the per-track information derived from FLUKA Monte Carlo simulations with the radiobiological effectiveness provided by the microdosimetric kinetic model and the local effect model. Thanks to an extension of the superposition concept, the beamlet irradiation action superposition is applicable for the evaluation of dose, RBE and LET distributions. The weight function for the beamlets superposition is derived from the beam phase space density at the patient entrance. A general beam model commissioning procedure is proposed, which has successfully been tested on the CNAO beam line. The BS model provides the evaluation of different irradiation quantities for different ions, the adaptability permitted by weight functions and the evaluation speed of analitical approaches. Benchmarking plans in simple geometries and clinical plans are shown to demonstrate the model capabilities.

  20. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  1. In situ study of topography, phase and volume changes of titanium dioxide anode in all-solid-state thin film lithium-ion battery by biased scanning probe microscopy

    Science.gov (United States)

    Zhu, Jing; Feng, Jinkui; Lu, Li; Zeng, Kaiyang

    2012-01-01

    In this study, local cyclic changes of surface topography, phase and volume of TiO2 anode within an all-solid-state thin film Li-ion battery (TiO2/LiPON/LiNi1/3Co1/3Mn1/3O2) at nanoscale are studied. These changes are caused by reversible bias-induced electric field through an in situ scanning probe microscopy (SPM) without external electrochemical attachment. Combining simultaneous measurements of phase and amplitude images, high spatially resolved mapping of “nano-spots” related to Li+ distribution can be obtained, providing new insight into the ionic transport mechanism and diffusion preferred paths in a real all-solid-state thin film lithium ion battery. In addition, the thin film anode shows reversible topographical changes as the volume expansion/contraction is related to the cyclic Li+ insertion/extraction, which are analogues to the charge/discharge behavior observed in electrochemical atomic force microscopy (EC-AFM) studies. The results suggest that the applications of local reversible biases are very useful for modeling the charge/discharge processes of lithium ion batteries.

  2. Adsorption behavior of poly(dimethyl-diallylammonium chloride) on pulp fiber studied by cryo-time-of-flight secondary ion mass spectrometry and cryo-scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Masumi, Takashi [Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho Chikusa-ku, Nagoya, Aichi 464-8601 (Japan); Matsushita, Yasuyuki, E-mail: ysmatsu@agr.nagoya-u.ac.jp [Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho Chikusa-ku, Nagoya, Aichi 464-8601 (Japan); Aoki, Dan [Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho Chikusa-ku, Nagoya, Aichi 464-8601 (Japan); Takama, Ruka [Technical Center, Nagoya University, Furo-cho Chikusa-ku Nagoya, Aichi 464-8601 (Japan); Saito, Kaori [Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho Chikusa-ku, Nagoya, Aichi 464-8601 (Japan); Kuroda, Katsushi [Department of Wood Properties, Forestry and Forest Products Research Institute, 1 Matsunosato, Tsukuba, Ibaraki 305-8687 (Japan); Fukushima, Kazuhiko [Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho Chikusa-ku, Nagoya, Aichi 464-8601 (Japan)

    2014-01-15

    In this study, the adsorption behavior of poly(dimethyl-diallylammonium chloride) (PDADMAC), a retention agent used in papermaking, in a dual polymer system with anionic poly(acrylamide) (A-PAM) was investigated by time-of-flight secondary ion mass spectrometry (TOF-SIMS). Initially, fragment structures and cleavage patterns were identified via TOF-SIMS experiments with deuterium-labeled PDADMAC and the unlabeled analogue. Visualization of PDADMAC on a dry handsheet surface using traditional TOF-SIMS analysis indicated that the electrostatic interaction between coagulated PDADMAC and A-PAM was relatively weak. A novel cryo-TOF-SIMS/SEM system enabled the evaluation of a wet handsheet containing PDADMAC. Analysis of this sample indicated that PDADMAC adsorbs onto the fiber surface and collects preferentially on the tangled fibrils located between fibers.

  3. Adsorption behavior of poly(dimethyl-diallylammonium chloride) on pulp fiber studied by cryo-time-of-flight secondary ion mass spectrometry and cryo-scanning electron microscopy

    International Nuclear Information System (INIS)

    In this study, the adsorption behavior of poly(dimethyl-diallylammonium chloride) (PDADMAC), a retention agent used in papermaking, in a dual polymer system with anionic poly(acrylamide) (A-PAM) was investigated by time-of-flight secondary ion mass spectrometry (TOF-SIMS). Initially, fragment structures and cleavage patterns were identified via TOF-SIMS experiments with deuterium-labeled PDADMAC and the unlabeled analogue. Visualization of PDADMAC on a dry handsheet surface using traditional TOF-SIMS analysis indicated that the electrostatic interaction between coagulated PDADMAC and A-PAM was relatively weak. A novel cryo-TOF-SIMS/SEM system enabled the evaluation of a wet handsheet containing PDADMAC. Analysis of this sample indicated that PDADMAC adsorbs onto the fiber surface and collects preferentially on the tangled fibrils located between fibers.

  4. Adsorption behavior of poly(dimethyl-diallylammonium chloride) on pulp fiber studied by cryo-time-of-flight secondary ion mass spectrometry and cryo-scanning electron microscopy

    Science.gov (United States)

    Masumi, Takashi; Matsushita, Yasuyuki; Aoki, Dan; Takama, Ruka; Saito, Kaori; Kuroda, Katsushi; Fukushima, Kazuhiko

    2014-01-01

    In this study, the adsorption behavior of poly(dimethyl-diallylammonium chloride) (PDADMAC), a retention agent used in papermaking, in a dual polymer system with anionic poly(acrylamide) (A-PAM) was investigated by time-of-flight secondary ion mass spectrometry (TOF-SIMS). Initially, fragment structures and cleavage patterns were identified via TOF-SIMS experiments with deuterium-labeled PDADMAC and the unlabeled analogue. Visualization of PDADMAC on a dry handsheet surface using traditional TOF-SIMS analysis indicated that the electrostatic interaction between coagulated PDADMAC and A-PAM was relatively weak. A novel cryo-TOF-SIMS/SEM system enabled the evaluation of a wet handsheet containing PDADMAC. Analysis of this sample indicated that PDADMAC adsorbs onto the fiber surface and collects preferentially on the tangled fibrils located between fibers.

  5. Quantitative profiling of PE, MMPE, DMPE, and PC lipid species by multiple precursor ion scanning: A tool for monitoring PE metabolism

    DEFF Research Database (Denmark)

    Bilgin, Mesut; Markgraf, Daniel F; Duchoslav, Eva;

    2011-01-01

    We report a method for the simultaneous identification and quantification of phosphatidylethanolamine (PE), monomethyl-phosphatidylethanolamine (MMPE), dimethyl-phosphatidylethanolamine (DMPE), and phosphatidylcholine (PC) species in lipid extracts. The method employs a specific "mass-tag" strategy...... where DMPE, MMPE, and PE species are chemically methylated with deuterated methyliodide (CD(3)I) to produce PC molecules having class-specific mass offsets of 3, 6 and 9Da, respectively. The derivatized aminoglycerophospholipids release characteristic phosphorylcholine-like fragment ions having specific...... and DMPE, and abundant PE and PC species in a single mass spectrometric analysis. We demonstrated the efficacy of the methodology by conducting a series of biochemical experiments using stable isotope labeled ethanolamine to survey the activities and substrate specificities of enzymes involved in PE...

  6. Thyroid Scan and Uptake

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ... the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan is a ...

  7. Pelvic CT scan

    Science.gov (United States)

    ... axial tomography scan - pelvis; Computed tomography scan - pelvis; CT scan - pelvis ... Risks of CT scans include: Being exposed to radiation Allergic reaction to contrast dye CT scans do expose you to more radiation ...

  8. Cervical spine CT scan

    Science.gov (United States)

    ... cervical spine; Computed tomography scan of cervical spine; CT scan of cervical spine; Neck CT scan ... Risks of CT scans include: Being exposed to radiation Allergic reaction to contrast dye CT scans expose you to more radiation than ...

  9. Sinus CT scan

    Science.gov (United States)

    ... axial tomography scan - sinus; Computed tomography scan - sinus; CT scan - sinus ... Risks of a CT scan includes: Being exposed to radiation Allergic reaction to contrast dye CT scans expose you to more radiation than regular ...

  10. 数控机床直线伺服系统智能反推控制的研究%Study on Intelligent Backstepping for Linear Servo System of NC Machine Tool

    Institute of Scientific and Technical Information of China (English)

    关丽荣

    2012-01-01

    针对高速高精数控机床直线伺服系统,考虑参数变化、外部负载扰动和摩擦力等不确定因素对系统伺服性能的影响,设计基于递归模糊神经网络( RFNN)的反推控制器,利用了递归神经网络具有捕获系统动态信息的优点,可实时补偿不确定因素对跟踪性能的影响.仿真结果表明,该控制策略明显降低了不确定因素对系统性能的影响,从而显著提高了直线伺服系统的位置跟踪精度.%In view of high speed and precise NC machine tool droved by linear servo systems, an adaptive backstepping sliding mode controller (ABSMC) was proposed considering the influence of the lumped uncertainties with parameter variations, external force disturbances and frictions for linear servo systems. , an intelligence backstepping control is introduced to suppress further the tracking error. Considering the influence of the lumped uncertainties with parameter variations, external force disturbances and frictions for PMLSM, a backstepping controller based on recurrent neural network is designed. The advantages of recurrent neural network with capturing the dynamic information of system are used, can compensate real time the influence of tracking performance. Simulation results show that the proposed algorithm can reduce effectively the influence of the lumped uncertainties on system performances. The tracking performances of the PMLSM servo system are significantly improved.

  11. Abdominal CT scan

    Science.gov (United States)

    Computed tomography scan - abdomen; CT scan - abdomen; CAT scan - abdomen; CT abdomen and pelvis ... An abdominal CT scan makes detailed pictures of the structures inside your belly (abdomen) very quickly. This test may be used to ...

  12. Shoulder CT scan

    Science.gov (United States)

    CAT scan - shoulder; Computed axial tomography scan - shoulder; Computed tomography scan - shoulder; CT scan - shoulder ... stopping.) A computer creates separate images of the shoulder area. These are called slices. These images can ...

  13. Electron transfer with self-assembled copper ions at Au-deposited biomimetic films: mechanistic ‘anomalies’ disclosed by temperature- and pressure-assisted fast-scan voltammetry

    International Nuclear Information System (INIS)

    It has been suggested that electron transfer (ET) processes occurring in complex environments capable of glass transitions, specifically in biomolecules, under certain conditions may experience the medium’s nonlinear response and nonergodic kinetic patterns. The interiors of self-assembled organic films (SAMs) deposited on solid conducting platforms (electrodes) are known to undergo glassy dynamics as well, hence they may also exhibit the abovementioned ‘irregularities’. We took advantage of Cu2+ ions as redox-active probes trapped in the Au-deposited  −COOH-terminated SAMs, either L-cysteine, or 3-mercaptopropionic acid diluted by the inert 2-mercaptoethanol, to systematically study the impact of glassy dynamics on ET using the fast-scan voltammetry technique and its temperature and high-pressure extensions. We found that respective kinetic data can be rationalized within the extended Marcus theory, taking into account the frictionally controlled (adiabatic) mechanism for short-range ET, and complications due to the medium’s nonlinear response and broken ergodicity. This combination shows up in essential deviations from the conventional energy gap (overpotential) dependence and in essentially nonlinear temperature (Arrhenius) and high-pressure patterns, respectively. Biomimetic aspects for these systems are also discussed in the context of recently published results for interfacial ET involving self-assembled blue copper protein (azurin) placed in contact with a glassy environment. (paper)

  14. Understanding the micro structure of Berea Sandstone by the simultaneous use of micro-computed tomography (micro-CT) and focused ion beam-scanning electron microscopy (FIB-SEM).

    Science.gov (United States)

    Bera, Bijoyendra; Mitra, Sushanta K; Vick, Douglas

    2011-07-01

    Berea sandstone is the building block for reservoirs containing precious hydrocarbon fuel. In this study, we comprehensively reveal the microstructure of Berea sandstone, which is often treated as a porous material with interconnected micro-pores of 2-5 μm. This has been possible due to the combined application of micro-computed tomography (CT) and focused ion beam (FIB)-scanning electron microscopy (SEM) on a Berea sample. While the use of micro-CT images are common for geological materials, the clubbing and comparison of tomography on Berea with state-of-the-art microstructure imaging techniques like FIB-SEM reveals some unforeseen features of Berea microstructure. In particular, for the first time FIB-SEM has been used to understand the micro-structure of reservoir rock material like Berea sandstone. By using these characterization tools, we are able to show that the micro-pores (less than 30 μm) are absent below the solid material matrix, and that it has small interconnected pores (30-40 μm) and large crater-like voids (100-250 μm) throughout the bulk material. Three-dimensional pore space reconstructions have been prepared from the CT images. Accordingly, characterization of Berea sandstone specimen is performed by calculation of pore-structure volumes and determination of porosity values. PMID:21208806

  15. Photon and dilepton production at the Facility for Proton and Anti-Proton Research and beam-energy scan at the Relativistic Heavy-Ion Collider using coarse-grained microscopic transport simulations

    Science.gov (United States)

    Endres, Stephan; van Hees, Hendrik; Bleicher, Marcus

    2016-05-01

    We present calculations of dilepton and photon spectra for the energy range Elab=2 A to35 A GeV which will be available for the Compressed Baryonic Matter (CBM) experiment at the future Facility for Proton and Anti-Proton Research (FAIR). The same energy regime will also be covered by phase II of the beam-energy scan at the Relativistic Heavy-Ion Collider (RHIC-BES). Coarse-grained dynamics from microscopic transport calculations of the Ultrarelativistic Quantum Molecular Dynamics (UrQMD) model is used to determine temperature and chemical potentials, which allows for the use of dilepton and photon-emission rates from equilibrium quantum-field-theory calculations. The results indicate that nonequilibrium effects, the presence of baryonic matter, and the creation of a deconfined phase might show up in specific manners in the measurable dilepton invariant-mass spectra and in the photon transverse-momentum spectra. However, as the many influences are difficult to disentangle, we argue that the challenge for future measurements of electromagnetic probes will be to provide a high precision with uncertainties much lower than in previous experiments. Furthermore, a systematic study of the whole energy range covered by CBM at FAIR and RHIC-BES is necessary to discriminate between different effects, which influence the spectra, and to identify possible signatures of a phase transition.

  16. Head CT scan

    Science.gov (United States)

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial ... The x-rays produced by the CT scan are painless. Some people may ... hard table. Contrast given through a vein may cause a: Slight ...

  17. RBC nuclear scan

    Science.gov (United States)

    An RBC nuclear scan uses small amounts of radioactive material to mark (tag) red blood cells (RBCs). Your body is then ... scanner does not give off any radiation. Most nuclear scans (including an RBC scan) are not recommended ...

  18. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  19. Coronary Calcium Scan

    Science.gov (United States)

    ... the NHLBI on Twitter. What Is a Coronary Calcium Scan? A coronary calcium scan is a test ... you have calcifications in your coronary arteries. Coronary Calcium Scan Figure A shows the position of the ...

  20. Scan BIST with biased scan test signals

    Institute of Scientific and Technical Information of China (English)

    XIANG Dong; CHEN MingJing; SUN JiaGuang

    2008-01-01

    The conventional test-per-scan built-in self-test (BIST) scheme needs a number of shift cycles followed by one capture cycle.Fault effects received by the scan flip-flops are shifted out while shifting in the next test vector like scan testing.Unlike deterministic testing,it is unnecessary to apply a complete test vector to the scan chains.A new scan-based BIST scheme is proposed by properly controlling the test signals of the scan chains,Different biased random values are assigned to the test signals of scan flip-flops in separate scan chains.Capture cycles can be inserted at any clock cycle if necessary.A new testability estimation procedure according to the proposed testing scheme is presented.A greedy procedure is proposed to select a weight for each scan chain.Experimental results show that the proposed method can improve test effectiveness of scan-based BIST greatly,and most circuits can obtain complete fault coverage or very close to complete fault coverage.

  1. Scanning probe nanoimprint lithography

    Energy Technology Data Exchange (ETDEWEB)

    Dinelli, F; Baschieri, P [IPCF, Consiglio Nazionale delle Ricerche, CNR Campus, Via G. Moruzzi 1, Pisa PI 56100 (Italy); Menozzi, C; Facci, P [CNR-INFM S3 National Research Center on Nanostructure and BioSystems at Surfaces, Via Campi 213/a, 41100 Modena (Italy); Pingue, P, E-mail: pingue@sns.it [NEST, Scuola Normale Superiore and CNR-INFM, Piazza San Silvestro 12, I-56127 Pisa (Italy)

    2010-02-19

    The present paper reports on a novel lithographic approach at the nanoscale level, which is based on scanning probe microscopy (SPM) and nanoimprint lithography (NIL). The experimental set-up consists of an atomic force microscope (AFM) operated via software specifically developed for the purpose. In particular, this software allows one to apply a predefined external load for a given lapse of time while monitoring in real-time the relative distance between the tip and the sample as well as the normal and lateral force during the embossing process. Additionally, we have employed AFM tips sculptured by means of focused ion beam in order to create indenting tools of the desired shape. Anti-sticking layers can also be used to functionalize the tips if one needs to investigate the effects of different treatments on the indentation and de-molding processes. The lithographic capabilities of this set-up are demonstrated on a polystyrene NIL-patterned sample, where imprinted features have been obtained upon using different normal load values for increasing time intervals, and on a thermoplastic polymer film, where the imprint process has been monitored in real-time.

  2. Scanning probe nanoimprint lithography

    Science.gov (United States)

    Dinelli, F.; Menozzi, C.; Baschieri, P.; Facci, P.; Pingue, P.

    2010-02-01

    The present paper reports on a novel lithographic approach at the nanoscale level, which is based on scanning probe microscopy (SPM) and nanoimprint lithography (NIL). The experimental set-up consists of an atomic force microscope (AFM) operated via software specifically developed for the purpose. In particular, this software allows one to apply a predefined external load for a given lapse of time while monitoring in real-time the relative distance between the tip and the sample as well as the normal and lateral force during the embossing process. Additionally, we have employed AFM tips sculptured by means of focused ion beam in order to create indenting tools of the desired shape. Anti-sticking layers can also be used to functionalize the tips if one needs to investigate the effects of different treatments on the indentation and de-molding processes. The lithographic capabilities of this set-up are demonstrated on a polystyrene NIL-patterned sample, where imprinted features have been obtained upon using different normal load values for increasing time intervals, and on a thermoplastic polymer film, where the imprint process has been monitored in real-time.

  3. Evaluation of Pore Networks in Caprocks at Geologic Storage Sites: A Combined Study using High Temperature and Pressure Reaction Experiments, Small Angle Neutron Scattering, and Focused Ion Beam-Scanning Electron Microscopy

    Science.gov (United States)

    Mouzakis, K. M.; Sitchler, A.; Wang, X.; McCray, J. E.; Kaszuba, J. P.; Rother, G.; Dewers, T. A.; Heath, J. E.

    2011-12-01

    Low permeability rock units, often shales or mudstones, that overlie geologic formations under consideration for CO2 sequestration will help contain injected CO2. CO2 that does flow through these rocks will dissolve into the porewaters, creating carbonic acid lowering the pH. This perturbation of the system may result in mineral dissolution or precipitation, which can change the pore structure and impact the flow properties of the caprocks. In order to investigate the impacts that reaction can have on caprock pore structure, we performed a combination of high pressure high temperature reaction experiments, small angle neutron scattering (SANS) experiments and high resolution focused ion beam-scanning electron microscope (FIB-SEM) imaging on samples from the Gothic shale and Marine Tuscaloosa Group. Small angle neutron scattering was performed on unreacted and reacted caprocks at the High Flux Isotope Reactor at Oak Ridge National Laboratory. New precipitates and pores are observed in high-resolution images of the reacted samples. The precipitates have been preliminarily identified as gypsum or anhydrite, and sulfide minerals. Results from small angle neutron scattering, a technique that provides information about pores and pore/mineral interfaces at scales ~ 5 to 300 nm, show an increased porosity and specific surface area after reaction with brine and CO2. However, there appear to be differences in how the pore networks change between the two samples that are related to sample mineralogy and original pore network structure. Changes to pores and formation of new pores may lead to different capillary sealing behavior and permeability. This combination of controlled laboratory experiments, neutron scattering and high-resolution imaging provides detailed information about the geochemical processes that occur at the pore scale as CO2 reacts with rocks underground. Such information is integral to the evaluation of large-scale CO2 sequestration as a feasible technology

  4. Rapid Frequency Scan EPR

    OpenAIRE

    Tseitlin, Mark; Rinard, George A.; Quine, Richard W.; Eaton, Sandra S.; Eaton, Gareth R.

    2011-01-01

    In rapid frequency scan EPR with triangular scans, sufficient time must be allowed to insure that the magnetization in the x,y plane decays to baseline at the end of the scan, which typically is about 5 T2 after the spins are excited. To permit relaxation of signals excited toward the extremes of the scan the total scan time required may be much longer than 5 T2. However, with periodic, saw-tooth excitation, the slow-scan EPR spectrum can be recovered by Fourier deconvolution of data recorded...

  5. Sample preparation method for scanning force microscopy

    CERN Document Server

    Jankov, I R; Szente, R N; Carreno, M N P; Swart, J W; Landers, R

    2001-01-01

    We present a method of sample preparation for studies of ion implantation on metal surfaces. The method, employing a mechanical mask, is specially adapted for samples analysed by Scanning Force Microscopy. It was successfully tested on polycrystalline copper substrates implanted with phosphorus ions at an acceleration voltage of 39 keV. The changes of the electrical properties of the surface were measured by Kelvin Probe Force Microscopy and the surface composition was analysed by Auger Electron Spectroscopy.

  6. Three dimensional analysis of the pore space in fine-grained Boom Clay, using BIB-SEM (broad-ion beam scanning electron microscopy), combined with FIB (focused ion-beam) serial cross-sectioning, pore network modeling and Wood's metal injection

    Science.gov (United States)

    Hemes, Susanne; Klaver, Jop; Desbois, Guillaume; Urai, Janos

    2014-05-01

    The Boom Clay is, besides the Ypresian clays, one of the potential host rock materials for radioactive waste disposal in Belgium (Gens et al., 2003; Van Marcke & Laenen, 2005; Verhoef et al., 2011). To access parameters, which are relevant for the diffusion controlled transport of radionuclides in the material, such as porosity, pore connectivity and permeability, it is crucial to characterize the pore space at high resolution (nm-scale) and in 3D. Focused-ion-beam (FIB) serial cross-sectioning in combination with high resolution scanning electron microscopy (SEM), pore network modeling, Wood's metal injection and broad-ion-beam (BIB) milling, constitute a superior set of methods to characterize the 3D pore space in fine-grained, clayey materials, down to the nm-scale resolution. In the present study, we identified characteristic 3D pore space morphologies, determined the 3D volume porosity of the material and applied pore network extraction modeling (Dong and Blunt, 2009), to access the connectivity of the pore space and to discriminate between pore bodies and pore throats. Moreover, we used Wood's metal injection (WMI) in combination with BIB-SEM imaging to assess the pore connectivity at a larger scale and even higher resolution. The FIB-SEM results show a highly (~ 90 %) interconnected pore space in Boom Clay, down to the resolution of ~ 3E+03 nm³ (voxel-size), with a total volume porosity of ~ 20 %. Pore morphologies of large (> 5E+08 nm³), highly interconnected pores are complex, with high surface area to volume ratios (shape factors G ~ 0.01), whereas small (areas (REAs) (Hemes et al., 2013).

  7. Lung PET scan

    Science.gov (United States)

    Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging ... A PET scan requires a small amount of tracer. The tracer is given through a vein (IV), usually on ...

  8. RBC nuclear scan

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  9. Atlas of duplex scanning

    International Nuclear Information System (INIS)

    This book presents the first atlas devoted entirely to duplex scanning. It details the uses of this important ''up-and-coming'' diagnostic tool for vascular and general surgeons and radiologists. It also covers scanning of the extremities, as well as the carotoids. The topics also covered are correlative line drawings elaborate and clarify the excellent scan images; the principles of duplex scanning or arteries and veins, techniques, and results; pictures normal anatomy; venous thromboses, arterial occlusion, true and false aneurysms, graft stenoses

  10. Pulmonary ventilation/perfusion scan

    Science.gov (United States)

    V/Q scan; Ventilation/perfusion scan; Lung ventilation/perfusion scan ... A pulmonary ventilation/perfusion scan is actually two tests. They may be done separately or together. During the perfusion scan, a health ...

  11. Rapid frequency scan EPR.

    Science.gov (United States)

    Tseitlin, Mark; Rinard, George A; Quine, Richard W; Eaton, Sandra S; Eaton, Gareth R

    2011-08-01

    In rapid frequency scan EPR with triangular scans, sufficient time must be allowed to insure that the magnetization in the x, y plane decays to baseline at the end of the scan, which typically is about 5T(2) after the spins are excited. To permit relaxation of signals excited toward the extremes of the scan the total scan time required may be much longer than 5T(2). However, with periodic, saw-tooth excitation, the slow-scan EPR spectrum can be recovered by Fourier deconvolution of data recorded with a total scan period of 5T(2), even if some spins are excited later in the scan. This scan time is similar to polyphase excitation methods. The peak power required for either polyphase excitation or rapid frequency scans is substantially smaller than for pulsed EPR. The use of an arbitrary waveform generator (AWG) and cross loop resonator facilitated implementation of the rapid frequency scan experiments reported here. The use of constant continuous low B(1), periodic excitation waveform, and constant external magnetic field is similar to polyphase excitation, but could be implemented without the AWG that is required for polyphase excitation. PMID:21664848

  12. Line-scanning, stage scanning confocal microscope

    Science.gov (United States)

    Carucci, John A.; Stevenson, Mary; Gareau, Daniel

    2016-03-01

    We created a line-scanning, stage scanning confocal microscope as part of a new procedure: video assisted micrographic surgery (VAMS). The need for rapid pathological assessment of the tissue on the surface of skin excisions very large since there are 3.5 million new skin cancers diagnosed annually in the United States. The new design presented here is a confocal microscope without any scanning optics. Instead, a line is focused in space and the sample, which is flattened, is physically translated such that the line scans across its face in a direction perpendicular to the line its self. The line is 6mm long and the stage is capable of scanning 50 mm, hence the field of view is quite large. The theoretical diffraction-limited resolution is 0.7um lateral and 3.7um axial. However, in this preliminary report, we present initial results that are a factor of 5-7 poorer in resolution. The results are encouraging because they demonstrate that the linear array detector measures sufficient signal from fluorescently labeled tissue and also demonstrate the large field of view achievable with VAMS.

  13. Radionucleotide scanning in osteomyelitis

    International Nuclear Information System (INIS)

    Radionucleotide bone scanning can be an excellent adjunct to the standard radiograph and clinical findings in the diagnosis of osteomyelitis. Bone scans have the ability to detect osteomyelitis far in advance of the standard radiograph. The sequential use of technetium and gallium has been useful in differentiating cellulitis and osteomyelitis. Serial scanning with technetium and gallium may be used to monitor the response of osteomyelitis to antibiotic therapy

  14. Getting a CAT Scan

    Medline Plus

    Full Text Available ... Snowboarding, Skating Crushes What's a Booger? Getting a CAT Scan (Video) KidsHealth > For Kids > Getting a CAT Scan (Video) Print A A A Text Size en español Obtención de una tomografía computada (video) CAT stands for "computerized axial tomography." Translated, that means ...

  15. Getting a CAT Scan

    Medline Plus

    Full Text Available ... Here's Help White House Lunch Recipes Getting a CAT Scan (Video) KidsHealth > For Kids > Getting a CAT Scan (Video) Print A A A Text Size en español Obtención de una tomografía computada (video) CAT stands for "computerized axial tomography." Translated, that means ...

  16. Abdominal CT scan

    Science.gov (United States)

    ... than regular x-rays. Many x-rays or CT scans over time may increase your risk for cancer. However, the risk from any one scan is small. Talk to your doctor about this risk and the benefit of the test for getting a correct diagnosis ...

  17. Knee CT scan

    Science.gov (United States)

    Risks of CT scans include: Exposure to radiation Allergy to contrast dye CT scans give off more radiation than ... injected contrast dye. The most common type of contrast contains ... you have this an iodine allergy. If you need to have this kind of ...

  18. Knee CT scan

    Science.gov (United States)

    A computed tomography (CT) scan of the knee is a test that uses x-rays to take detailed images of the knee. ... A CT scan can quickly create more detailed pictures of the knee than standard x-rays. The test may be ...

  19. Frequency scanning microstrip antennas

    DEFF Research Database (Denmark)

    Danielsen, Magnus; Jørgensen, Rolf

    1979-01-01

    The principles of using radiating microstrip resonators as elements in a frequency scanning antenna array are described. The resonators are cascade-coupled. This gives a scan of the main lobe due to the phase-shift in the resonator in addition to that created by the transmission line phase...

  20. Environmental Scanning Report.

    Science.gov (United States)

    Truckee Meadows Community Coll., Sparks, NV.

    This report describes Truckee Meadows Community College's (Nevada) environmental scanning process and results. The college decided that environmental scanning and forecasting techniques should be used to plan for both short-term and long-term external factors that impact programs, enrollment, and budgets. Strategic goals include: (1) keeping pace…

  1. Getting a CAT Scan

    Medline Plus

    Full Text Available ... Dictionary of Medical Words En Español What Other Kids Are Reading Movie: Digestive System Winter Sports: Sledding, ... Booger? Getting a CAT Scan (Video) KidsHealth > For Kids > Getting a CAT Scan (Video) Print A A ...

  2. Getting a CAT Scan

    Medline Plus

    Full Text Available ... Skiing, Snowboarding, Skating Crushes What's a Booger? Getting a CAT Scan (Video) KidsHealth > For Kids > Getting a CAT Scan (Video) Print A A A Text Size en español Obtención de ...

  3. Getting a CAT Scan

    Medline Plus

    Full Text Available ... Crushes What's a Booger? Getting a CAT Scan (Video) KidsHealth > For Kids > Getting a CAT Scan (Video) Print A A A Text Size en español Obtención de una tomografía computada (video) CAT stands for "computerized axial tomography." Translated, that ...

  4. Laser Scanning in Forests

    Directory of Open Access Journals (Sweden)

    Håkan Olsson

    2012-09-01

    Full Text Available The introduction of Airborne Laser Scanning (ALS to forests has been revolutionary during the last decade. This development was facilitated by combining earlier ranging lidar discoveries [1–5], with experience obtained from full-waveform ranging radar [6,7] to new airborne laser scanning systems which had components such as a GNSS receiver (Global Navigation Satellite System, IMU (Inertial Measurement Unit and a scanning mechanism. Since the first commercial ALS in 1994, new ALS-based forest inventory approaches have been reported feasible for operational activities [8–12]. ALS is currently operationally applied for stand level forest inventories, for example, in Nordic countries. In Finland alone, the adoption of ALS for forest data collection has led to an annual savings of around 20 M€/year, and the work is mainly done by companies instead of governmental organizations. In spite of the long implementation times and there being a limited tradition of making changes in the forest sector, laser scanning was commercially and operationally applied after about only one decade of research. When analyzing high-ranked journal papers from ISI Web of Science, the topic of laser scanning of forests has been the driving force for the whole laser scanning research society over the last decade. Thus, the topic “laser scanning in forests” has provided a significant industrial, societal and scientific impact. [...

  5. Scanning with Iodine-125

    International Nuclear Information System (INIS)

    The use of I125 as I125-iodide for scanning of the thyroid and of thyroid carcinoma métastasés and as I125-labelled Rose Bengal for scanning of the liver has been investigated in our laboratories. In some patients, the thyroid scans and the scans of thyroid carcinoma metastases were repeated with I131. The liver scans were repeated with colloidal Au198. Cold nodules in the thyroid which could not be detected with I131 were clearly seen with I125. Anterior métastasés in the lungs could be differentiated from posterior métastasés with I125, while with I131 this was not possible. Using the same doses of radioactivity the background with I131 was much higher and could not be eliminated, as this would have reduced the counting rate over the lesions to levels which could not be detected. Some of the photoscans and mechanical scans of livers carried out with colloidal Au198 could not be interpreted. However, ''cold'' lesions were clearly seen on the scans of the same livers with I125-labelled Rose Bengal. (author)

  6. Breast PET scan

    Science.gov (United States)

    Breast positron emission tomography; PET - breast; PET - tumor imaging - breast ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), usually ...

  7. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  8. Shoulder MRI scan

    Science.gov (United States)

    ... finding on an x-ray or bone scan Shoulder pain and fever Decreased motion of the shoulder joint ... of the shoulder joint Shoulder instability Shoulder weakness Shoulder pain and a history of cancer Shoulder pain that ...

  9. Scanning ultrafast electron microscopy

    OpenAIRE

    Yang, Ding-Shyue; Mohammed, Omar F.; Zewail, Ahmed H.

    2010-01-01

    Progress has been made in the development of four-dimensional ultrafast electron microscopy, which enables space-time imaging of structural dynamics in the condensed phase. In ultrafast electron microscopy, the electrons are accelerated, typically to 200 keV, and the microscope operates in the transmission mode. Here, we report the development of scanning ultrafast electron microscopy using a field-emission-source configuration. Scanning of pulses is made in the single-electron mode, for whic...

  10. Advanced Network Scanning

    Directory of Open Access Journals (Sweden)

    Ashiqur Rahman

    2016-07-01

    Full Text Available Network scanning is à procedure for identifying active hosts on a network, either for the purpose of attacking them or for network security assessment. Scanning procedures, such as ping sweeps and port scans, return information about which IP addresses map to live hosts that are active on the Internet and what services they offer. Another scanning method, inverse mapping, returns information about what IP addresses do not map to live hosts; this enables an attacker to make assumptions about viable addresses. Scanning is one of three components of intelligence gathering for an attacker. In the foot printing phase, the attacker creates a profile of the target organization, with information such as its domain name system (DNS and e-mail servers, and its IP address range. Most of this information is available online. In the scanning phase, the attacker finds information about the specific IP addresses that can be accessed over the Internet, their operating systems, the system architecture, and the services running on each computer. In the enumeration phase, the attacker gathers information such as network user and group names, routing tables, and Simple Network Management Protocol (SNMP data

  11. Uniform irradiation system using beam scanning method for cyclotron

    International Nuclear Information System (INIS)

    JAERI AVF-cyclotron is equipped with an ion beam scanner for large area irradiation. The two-dimensional fluence distribution of ion beam obtained using cellulose triacetate film dosimeter was not uniform. This is resulted from the distortion of excitation current for electromagnet of the scanner. So, the beam scanning condition, i.e., the relation between the ion species, the beam profile and the scanning width, was extremely limited to make a good uniformity. We have developed a beam scanning simulator to get fluence distributions by calculation and then compared the simulated distributions with the measured ones. It was revealed that the both of them are in good agreement and the beam scanning condition to get good uniformity was led by using this simulator. On the basis of these results, the power supply of scanner was improved. A good uniformity of beam distribution was available. (author)

  12. Ion beam diagnosis

    International Nuclear Information System (INIS)

    This report is an introduction to ion beam diagnosis. After a short description of the most important ion beam parameters measurements of the beam current by means of Faraday cups, calorimetry, and beam current transformers and measurements of the beam profile by means of viewing screens, profile grids and scanning devices, and residual gas ionization monitors are described. Finally measurements in the transverse and longitudinal phase space are considered. (HSI)

  13. 自适应反演滑模控制在火箭炮交流伺服系统中的应用%Application of Adaptive Backstepping Sliding Mode Controlin in Alternative Current Servo System of Rocket Gun

    Institute of Scientific and Technical Information of China (English)

    郭亚军; 王晓锋; 马大为; 乐贵高

    2011-01-01

    A adaptive backstepping sliding mode control approach was introduced to control the pitch motion of a rocket gun. Its control law was proposed to guarantee that the control system was ultimately bounded in a Lyapunov sense and make the servo system could track the instruction of reference position globally and asymptotically. In addition, the sliding mode control can restrain effects of parameter uncertainties and external disturbance. The functions of adaptive mechanism and sliding mode control were analyzed by using simulation under different conditions. The simulation results illustrate that the method is applicable and robust.%针对某火箭炮俯仰运动的位置控制问题,采用了一种自适应反演滑模控制方法.自适应反演控制律保证了闭环系统最终有界,使伺服系统能够全局渐进跟踪参考位置指令,从而达到交流伺服系统稳定跟踪控制的目的,滑模控制抑制了模型参数摄动和外界干扰的影响.通过不同条件下的仿真研究,分析了自适应机制和滑模控制在运动控制中的作用,结果表明该方法具有较强的适应性及鲁棒性.

  14. Bone scanning in osteoporosis

    International Nuclear Information System (INIS)

    This paper reports on bone scanning in osteoporosis a diagnosis of osteoporosis most often follows fracture, and clearly this should be confirmed by x-ray. The bone scan therefore does not have an important role to play in the initial diagnosis of osteoporosis. While the exact mechanism by which the 99mTc-labeled diphosphonates localize in the skeleton is not fully understood, it is believed that they adsorb onto bone surfaces most probably via the calcium of hydroxyapatite crystals. Because the major factors that affect adsorption are osteoblastic activity and to a lesser extent skeletal vascularity, it is apparent that a bone scan image presents a functional display of skeletal metabolic activity. However, osteoporosis is a disorder in which gradual change in bone mass may occur over many years and, in keeping with this minor imbalance in skeletal metabolism, the bone scan appearances are usually normal. However, the scan images may appear of poor quality because of relatively low bone uptake of tracer with, on occasion, a washed-out pattern of activity in the axial and appendicular bone. It has been suggested that such a pattern occurs in severe or end-stage osteoporosis caused by markedly reduced osteoblastic activity. If kyphosis is observed on the bone scan or if there appears to be loss of spinal height with proximity of ribs to each other or increased closeness of rib cage to pelvis, then appearances suggest vertebral collapse and would be in keeping with a diagnosis of osteoporosis. Such evidence is, however, indirect and in practice a bone scan is an extremely unreliable means of diagnosing osteoporosis

  15. Bone scan in pediatrics

    International Nuclear Information System (INIS)

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99mTc diphosphonate (MDP); other isotopes used include 99mTc colloid for bone marrow scans and 67Ga citrate and 111In white blood cells (111In WBC) for investigation of inflammatory/infective lesions

  16. Lung Ventilation/Perfusion Scan

    Science.gov (United States)

    ... two types of scans: ventilation and perfusion. The ventilation scan shows where air flows in your lungs. The perfusion scan shows where blood flows in your lungs. Both scans use radioisotopes (a low-risk radioactive substance). For the ventilation scan, you ...

  17. Scanning Probe Microscopy and Spectroscopy

    Science.gov (United States)

    Wiesendanger, Roland

    1994-09-01

    Preface; List of acronyms; Introduction; Part I. Experimental Methods and Theoretical Background of Scanning Probe Microscopy and Spectroscopy: 1. Scanning tunnelling microscopy; 2. Scanning force microscopy; 3. Related scanning probe techniques; Part II. Applications of Scanning Probe Microscopy and Spectroscopy: 4. Condensed matter physics; 5. Chemistry; 6. Organic materials; 7. Metrology and standards; 8. Nanotechnology; References; Index.

  18. 液力自动变速器换挡过程的反演优化控制%Optimizing gear shifting quality with backstepping control for automatic transmission

    Institute of Scientific and Technical Information of China (English)

    赵鑫鑫; 杨珏; 张静; 张文明

    2016-01-01

    The Automatic Transmission is widely equipped in the heavy-duty trucks, while the driving comfort reduction during gear shift is the major drawbacks, and the optimization of gear shifting process is quite challenging due to the various objectives. With the development of modern control theory, it has been widely applied into gear shifting duration, such as PID control, genetic algorithm and dynamic programming et al. In this paper, a backstepping control strategy is proposed to enhance the gear shift quality, which will transform the multi-objective optimization to a single target tracking as well. According to the gear shifting dynamic model, gear shifting can be divided into four phases, lower gear phase, torque phase, inertial phase and higher gear phase. The clutch output torques during engagement and disengagement are derived considering the motion states of the off-going and on-coming clutches. The trajectory target is defined on the basis of the rotatory input and output speed of the transmission. Since the torque is hard to be measured accurately and the transmission output speed does not has obvious change during the torque phase of gear shifting, we will adjust the current of pressure reducing valves in the inertial phase. By analyzing the motion states of off-going clutch and on-coming clutch, the mathematical model of output torque for clutches has been built in this paper. The backstepping method and state stability theory (ISS) are utilized in the sliding mode controller to control the synchronization torques by tuning the valves current. The shifting quality is assessed in terms of the shift time, jerk and sliding friction work which are considered into the objective function in sliding control problem. All of them are fitted as three-order polynomial functions, and the controller parameters are evaluated according to the system parameters and the margin of errors. Based on the reference trajectory, the speed of driven plate on-coming clutch

  19. Lung scans and malignancy

    International Nuclear Information System (INIS)

    An experience of pulmonary isotope scanning carried out with mercury 197 labelled mercury chloride and acetate, cobalt 57-labelled bleomycin, and Cu67 and Cu64 labelled copper citrate was presented. The scans were carried out with various isotopes supplied by the French Atomic Energy Authority, and gave comparable results, which may be summarised as follows: increased uptake in more than 90% of cases of carcinoma, absent uptake in all cases of benign tumour, frequent increased uptake in acute or advanced inflammatory lesions, absence of uptake, very commonly, in tuberculoma and chronic lesions with scar formation. Radio-isotope scan using Cu67 labelled copper citrate permitted discrimination of malignant tumours (increased fixation which showed up best at the 24th hour) from inflammatory lesions (increased fixation which was reduced on the 24th hour). The positive or negative character of the fixation in a given lesions remains the same, whatever the isotope used in our experience

  20. Bone scan in rheumatology

    International Nuclear Information System (INIS)

    In this chapter a revision is made concerning different uses of bone scan in rheumatic diseases. These include reflex sympathetic dystrophy, osteomyelitis, spondyloarthropaties, metabolic bone diseases, avascular bone necrosis and bone injuries due to sports. There is as well some comments concerning pediatric pathology and orthopedics. (authors). 19 refs., 9 figs

  1. Scanning bubble chamber pictures

    CERN Multimedia

    1974-01-01

    These were taken at the 2 m hydrogen bubble chamber. The photo shows an early Shiva system where the pre-measurements needed to qualify the event were done manually (cf photo 7408136X). The scanning tables were located in bld. 12. Gilberte Saulmier sits on foreground, Inge Arents at centre.

  2. Getting a CAT Scan

    Medline Plus

    Full Text Available ... The scan itself is painless. All you'll need to do is hold still for a few minutes at a time so the pictures come out clear ... the Nemours Web site. Note: All information on KidsHealth® is for educational purposes only. For ...

  3. Scan This Book!

    Science.gov (United States)

    Albanese, Andrew Richard

    2007-01-01

    In this article, the author presents an interview with Brewster Kahle, leader of the Open Content Alliance (OCA). OCA book scan program is an alternative to Google's library project that aims to make books accessible online. In this interview, Kahle discusses his views on the challenges of getting books on the Web, on Google's library…

  4. Surface micromachined scanning mirrors

    DEFF Research Database (Denmark)

    Mattsson, Kent Erik

    Both aluminum cantilever and torsional scanning mirrors have been fabricated and their static and dynamic properties are studied experimentally and theoretically. The experiments showed resonance frequencies in the range of 163 k-Hz - 632 kHz for cantilever beams with Q values between 5 and 11. T...

  5. Lung gallium scan

    Science.gov (United States)

    ... Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the A.D.A.M. Editorial team. Related MedlinePlus Health Topics Lung Diseases Nuclear Scans Sarcoidosis Browse the Encyclopedia A.D.A. ...

  6. Micromachining using focused ion beams

    International Nuclear Information System (INIS)

    Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

  7. Non-contact scanning ion conductance microscopy for high-resolution morphological imaging of live cells%非接触式扫描离子电导显微镜技术在探测活体细胞表面微结构中的应用

    Institute of Scientific and Technical Information of China (English)

    杨茜; 刘晓; 马丽颖; 李长峰; 鲍亚盟; 高瑞玲; 张西正; 张彦军

    2009-01-01

    As a new kind of scanning probe microscopy,scanning ion conductance microscopy (SICM) is designed for imaging non-conducting biological sample at the nanometer scale. Firstly, nanometer scale glass micropipettes were pulled successfully, and were functionally evaluated. Secondly, a micropipette-sample approaching curve was obtained for describing the working principle of SICM. Finally, SICM was used to scan the morphology of a conductive standard sample and live renal epithelial A6 cells. The topography of A6 cells monolayer was verified with Scanning Electron Microscopy (SEM) observation. As a result, non-contact SICM can be used not only for scanning conductive samples, but also for acquiring 30 morphological image of non-conducting living cells. It provides a powerful tool for in-depth studying the relationship between the cell membrane microstructures and their physiological functions.%扫描离子电导显微镜技术是在纳米尺度进行非导电的生物样品成像的一种新型扫描探针显微镜技术.通过成功制备扫描离子电导显微镜扫描探测用纳米尺度玻璃微探针,对其进行了功能性评估;而后通过绘制探针-样品接近曲线,阐述了扫描离子电导显微镜技术实现非接触高分辨率探测的工作原理;最后采用该显微镜技术对导电标准样品及活体肾上皮A6细胞进行了表面形貌扫描成像,并与A6细胞表面形貌的扫描电镜图像进行了对照.结果表明,扫描离子电导显微镜技术不仅可实现导电样品的扫描成像,而且适宜于在生理条件下、非接触式地研究活体细胞表面的三维形貌,从而为人们深入研究细胞表面微观结构与生理功能提供了全新的技术手段.

  8. A new scanning proton microprobe with long focus

    International Nuclear Information System (INIS)

    A new scanning proton microprobe equipped with a long focus Russian magnetic quadruplet is set up. With excellent performances of ion optics, it can be used to do experiments of PIXE, RBS, RFS, NRA and channelling simultaneously within a micron-region. The power supplies for quadruplet and scanning coils are controlled by an IBM-PC computer and a scanning graphical monitor based on an Apple IIe microcomputer provides convenience of searching for an interesting area to scan. The advanced modes of the fast random scan and the event-by-event data collection make it possible to treat the multi-parameter and multi-detector data by means of the strategy of TQSA (Total quantitative scanning analysis). There are three types of graphical display including the innovation of three dimensional contour mapping

  9. COSMIC: A Regimen of Intensity Modulated Radiation Therapy Plus Dose-Escalated, Raster-Scanned Carbon Ion Boost for Malignant Salivary Gland Tumors: Results of the Prospective Phase 2 Trial

    International Nuclear Information System (INIS)

    Purpose: To investigate the effect of intensity modulated radiation therapy (IMRT) and dose-escalated carbon ion (C12) therapy in adenoid cystic carcinoma (ACC) and other malignant salivary gland tumors (MSGTs) of the head and neck. Patients and Methods: COSMIC (combined treatment of malignant salivary gland tumors with intensity modulated radiation therapy and carbon ions) is a prospective phase 2 trial of 24 Gy(RBE) C12 followed by 50 Gy IMRT in patients with pathologically confirmed MSGT. The primary endpoint is mucositis Common Terminology Criteria grade 3; the secondary endpoints are locoregional control (LC), progression-free survival (PFS), overall survival (OS), and toxicity. Toxicity was scored according to the Common Terminology Criteria for Adverse Events version 3; treatment response was scored according to Response Evaluation Criteria in Solid Tumors 1.1. Results: Between July 2010 and August 2011, 54 patients were accrued, and 53 were available for evaluation. The median follow-up time was 42 months; patients with microscopically incomplete resections (R1, n=20), gross residual disease (R2, n=17), and inoperable disease (n=16) were included. Eighty-nine percent of patients had ACC, and 57% had T4 tumors. The most common primary sites were paranasal sinus (34%), submandibular gland, and palate. At the completion of radiation therapy, 26% of patients experienced grade 3 mucositis, and 20 patients reported adverse events of the ear (38%). The most common observed late effects were grade 1 xerostomia (49%), hearing impairment (25%, 2% ipsilateral hearing loss), and adverse events of the eye (20%), but no visual impairment or loss of vision. Grade 1 central nervous system necrosis occurred in 6%, and 1 grade 4 ICA hemorrhage without neurologic sequelae. The best response was 54% (complete response/partial remission). At 3 years, the LC, PFS, and OS were 81.9%, 57.9%, and 78.4%, respectively. No difference was found regarding resection status. The

  10. COSMIC: A Regimen of Intensity Modulated Radiation Therapy Plus Dose-Escalated, Raster-Scanned Carbon Ion Boost for Malignant Salivary Gland Tumors: Results of the Prospective Phase 2 Trial

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Alexandra D., E-mail: alexdjensen@gmx.de [Department of Radiation Oncology, University of Heidelberg, Heidelberg (Germany); Nikoghosyan, Anna V.; Lossner, Karen [Department of Radiation Oncology, University of Heidelberg, Heidelberg (Germany); Haberer, Thomas; Jäkel, Oliver [Heidelberg Ion Beam Therapy Centre, Heidelberg (Germany); Münter, Marc W.; Debus, Jürgen [Department of Radiation Oncology, University of Heidelberg, Heidelberg (Germany)

    2015-09-01

    Purpose: To investigate the effect of intensity modulated radiation therapy (IMRT) and dose-escalated carbon ion (C12) therapy in adenoid cystic carcinoma (ACC) and other malignant salivary gland tumors (MSGTs) of the head and neck. Patients and Methods: COSMIC (combined treatment of malignant salivary gland tumors with intensity modulated radiation therapy and carbon ions) is a prospective phase 2 trial of 24 Gy(RBE) C12 followed by 50 Gy IMRT in patients with pathologically confirmed MSGT. The primary endpoint is mucositis Common Terminology Criteria grade 3; the secondary endpoints are locoregional control (LC), progression-free survival (PFS), overall survival (OS), and toxicity. Toxicity was scored according to the Common Terminology Criteria for Adverse Events version 3; treatment response was scored according to Response Evaluation Criteria in Solid Tumors 1.1. Results: Between July 2010 and August 2011, 54 patients were accrued, and 53 were available for evaluation. The median follow-up time was 42 months; patients with microscopically incomplete resections (R1, n=20), gross residual disease (R2, n=17), and inoperable disease (n=16) were included. Eighty-nine percent of patients had ACC, and 57% had T4 tumors. The most common primary sites were paranasal sinus (34%), submandibular gland, and palate. At the completion of radiation therapy, 26% of patients experienced grade 3 mucositis, and 20 patients reported adverse events of the ear (38%). The most common observed late effects were grade 1 xerostomia (49%), hearing impairment (25%, 2% ipsilateral hearing loss), and adverse events of the eye (20%), but no visual impairment or loss of vision. Grade 1 central nervous system necrosis occurred in 6%, and 1 grade 4 ICA hemorrhage without neurologic sequelae. The best response was 54% (complete response/partial remission). At 3 years, the LC, PFS, and OS were 81.9%, 57.9%, and 78.4%, respectively. No difference was found regarding resection status. The

  11. 67Ga lung scan

    International Nuclear Information System (INIS)

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate 67Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the 67Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of 67Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of 67Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography

  12. Adrenal scanning in children

    International Nuclear Information System (INIS)

    Adrenal scanning with 131I-Adosterol is very useful and rather non-invasive than adrenal angiography in children. It is possible to diagnose various diseases of the adrenal glands not only structural but also functional abnormalities. In patients with adrenogenital syndromes, we are able to demonstrate hyperplasia of the adrenal glands, and in patients with aldosteronism or Cushing's syndrome differential diagnosis between bilateral hyperplasia and functional adenoma of the adrenal gland can be made. (author)

  13. Forensic Scanning Electron Microscope

    Science.gov (United States)

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  14. Further progress for a fast scanning of nuclear emulsions with Large Angle Scanning System

    International Nuclear Information System (INIS)

    The LASSO (Large Angle Scanning System for OPERA) is a scanning system designed in the framework of the OPERA experiment as a result of several R and Ds aimed to improve the performance of the European Scanning System (ESS) by increasing the scanning speed, the angular acceptance and the efficiency in microtrack reconstruction. The novel Continuous Motion (CM) scanning approach allows to double the ESS nominal speed without any changes in the hardware set-up. The LASSO modular design makes the system easily adaptable to new hardware. The novel microtrack reconstruction algorithm has been developed to be efficient in both standard Stop and Go (SG) and CM modes, performing a number of corrections during the processing like corrections for vibrations, optical distortions, field of view curvature. As an intermediate step it reconstructs silver grains positions inside emulsion layer to make a transition from 2D images to real 3D traces of a charged particle. This allows the algorithm to have no internal limits on the slope of microtracks being equally efficient on all angles. The LASSO has been used for about one year for mass production scanning of emulsion films of OPERA, Muon Radiography and also of films employed to study nuclear fragmentation of ion beams used in medical physics. More than 50000 cm2 of the emulsion surface have been analyzed during this period

  15. Advances in Modeling of Scanning Charged-Particle-Microscopy Images

    OpenAIRE

    Cizmar, Petr; Vladar, Andras E.; Postek, Michael T.

    2010-01-01

    Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM im...

  16. Visualization in Scanning

    International Nuclear Information System (INIS)

    Scanning is essentially a method of making the unknown known, and for the vast majority of scanning work this means making the invisible visible. Visualization is developed as a process involving a model of eye and brain function, display performance and counter performance combined with the spatial frequency components in the object scanned. The performance of a scanner or gamma camera depends in part on its display system and experiments have been performed to determine the fractional change in count-rate which can be perceived by the eye from colour, photoscan and cathode-ray tube displays, for both circular and line sources of radioactivity. For circular sources, colour and photoscan displays are capable of making 10% increases in count-rate perceptible in backgrounds ranging from 5 to 100 counts/s for sources of 1 to 4 cm diameter, whilst cathode-ray tube and black-mark displays show only 20% at best. The results for line sources are also given. In testing for the statistical significance of count-rate differences on a scan, the counts are usually compared for equal areas. On this basis the cathode-ray tube display is only able to show five standard deviations of difference whereas colour and photoscan displays show from 2.5 to 3 standard deviations, levels not usually accepted statistically as significant. It is suggested that if the eye examines the areas surrounding the area of interest then the significance of a count-rate difference may be established more accurately and in general will be increased, thereby accounting for the visualization of apparently 'insignificant' regions. This theory is used to predict the areas of count density which should be visually perceived in the presence of noise, and extended to consider practical display conditions, which have been described in this paper. The performance of a scanner can be considered in terms of its modulation transfer function (derived from a line spread function). Fourier analysis has been performed

  17. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  18. SU-E-T-594: Preliminary Active Scanning Results of KHIMA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, C; Yang, T; Chang, S; Kim, H; Lee, H; Kim, J; Jang, H; Han, G; Park, D; Hwang, W; Kim, G [Korea Institute of Radiological and Medical Science, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: To verify the design criteria on heavy ion beam irradiation, developing a proto type active scanning system was purposed. The active scanning system consists of scanning magnet, power supplies, beam monitors, energy modulation system, and irradiation control system. Methods: Each components of the active scanning system was designed for carbon beam first. For the fast ramping a laminated yoke was purposed. To measure incoming dose and profile, a plate and strip type of ion chambers were designed. Also, ridge filter and range shifter was manufactured. And, the scanning system was modified to adopt 45 MeV of proton beam because of the absence of carbon ion beam in Korea. The system was installed in a beam line at MC-50, KIRAMS. Also, the irradiation control system and planning software was provided. Results: The scanning experiment was performed by drawing KHIMA logo on GaF film. The logo was scanned by 237 scanning points through time normalized intensity modulation. Also, a grid points scanning was performed to measure the scanning resolution and intensity resolution. Conclusion: A prototype active scanning system was successfully designed and manufactured. Also, an initial experiment to print out a drawing on GaF film through the scanning system was completed. More experiments would be required to specify the system performance.

  19. SU-E-T-594: Preliminary Active Scanning Results of KHIMA

    International Nuclear Information System (INIS)

    Purpose: To verify the design criteria on heavy ion beam irradiation, developing a proto type active scanning system was purposed. The active scanning system consists of scanning magnet, power supplies, beam monitors, energy modulation system, and irradiation control system. Methods: Each components of the active scanning system was designed for carbon beam first. For the fast ramping a laminated yoke was purposed. To measure incoming dose and profile, a plate and strip type of ion chambers were designed. Also, ridge filter and range shifter was manufactured. And, the scanning system was modified to adopt 45 MeV of proton beam because of the absence of carbon ion beam in Korea. The system was installed in a beam line at MC-50, KIRAMS. Also, the irradiation control system and planning software was provided. Results: The scanning experiment was performed by drawing KHIMA logo on GaF film. The logo was scanned by 237 scanning points through time normalized intensity modulation. Also, a grid points scanning was performed to measure the scanning resolution and intensity resolution. Conclusion: A prototype active scanning system was successfully designed and manufactured. Also, an initial experiment to print out a drawing on GaF film through the scanning system was completed. More experiments would be required to specify the system performance

  20. Nuclear Medicine Scans for Cancer

    Science.gov (United States)

    ... My ACS » Your Local Offices Close + - Text Size Nuclear Medicine Scans for Cancer Other names for these ... inflammation, or cancer. Use of monoclonal antibodies in nuclear scans A special type of antibody made in ...

  1. Scanned-cantilever atomic force microscope with large scanning range

    Institute of Scientific and Technical Information of China (English)

    Jintao Yang; Wendong Xu

    2006-01-01

    A scanned-cantilever atomic force microscope (AFM) with large scanning range is proposed, which adopts a new design named laser spot tracking. The scanned-cantilever AFM uses the separate flexure x-y scanner and z scanner instead of the conventional piezoelectric tube scanner. The closed-loop control and integrated capacitive sensors of these scanners can insure that the images of samples have excellent linearity and stability. According to the experimental results, the scanned-cantilever AFM can realize maximal 100 × 100 (μm) scanning range, and 1-nm resolution in z direction, which can meet the requirements of large scale sample testing.

  2. LOW ENERGY ION SCATTERING

    OpenAIRE

    2007-01-01

    Low energy ion scattering (LEIS) is the study of the composition and structure of a surface by the detection of low energy ions with energies ranging from 100 eV to 10 keV elastically scattered off the surface. The extreme sensitivity to the outermost atomic layer makes it as a unique tool for surface analysis. In this paper, concepts of shadowing, blocking, and also polar and azimuthal scans have been described. Surface order and surface atom spacings are revealed by using these concepts and...

  3. Quadrature wavelength scanning interferometry.

    Science.gov (United States)

    Moschetti, Giuseppe; Forbes, Alistair; Leach, Richard K; Jiang, Xiang; O'Connor, Daniel

    2016-07-10

    A novel method to double the measurement range of wavelength scanning interferometery (WSI) is described. In WSI the measured optical path difference (OPD) is affected by a sign ambiguity, that is, from an interference signal it is not possible to distinguish whether the OPD is positive or negative. The sign ambiguity can be resolved by measuring an interference signal in quadrature. A method to obtain a quadrature interference signal for WSI is described, and a theoretical analysis of the advantages is reported. Simulations of the advantages of the technique and of signal errors due to nonideal quadrature are discussed. The analysis and simulation are supported by experimental measurements to show the improved performances. PMID:27409307

  4. The normal bone scan

    International Nuclear Information System (INIS)

    This paper discusses applications of the bone scan. It is the most frequently performed nuclear medicine investigation, the commonest indication being the detection of occult metastases, for which purpose the entire skeleton should be imaged. For other purposes it is often adequate to examine only part of the skeleton. The amount of isotope taken up at any site depends primarily on the local rate of bone turnover rather than on bone mass. The scintigraphic appearance therefore does not necessarily correlate with the radiographic one; however, as there is a relationship between the rate at which bone is replaced and the quantity of bone which is present at any point, the two appearances are not entirely unrelated. Recognition of abnormality is based on a detailed knowledge of normal scintigraphic appearances

  5. Telescopic horizon scanning.

    Science.gov (United States)

    Koenderink, Jan

    2014-12-20

    The problem of "distortionless" viewing with terrestrial telescopic systems (mainly "binoculars") remains problematic. The so called "globe effect" is only partially counteracted in modern designs. Theories addressing the phenomenon have never reached definitive closure. In this paper, we show that exact distortionless viewing with terrestrial telescopic systems is not possible in general, but that it is in principle possible in-very frequent in battle field and marine applications-the case of horizon scanning. However, this involves cylindrical optical elements. For opto-electronic systems, a full solution is more readily feasible. The solution involves a novel interpretation of the relevant constraints and objectives. For final design decisions, it is not necessary to rely on a corpus of psychophysical (or ergonomic) data, although one has to decide whether the instrument is intended as an extension of the eye or as a "pictorial" device. PMID:25608206

  6. A Scanning Cavity Microscope

    CERN Document Server

    Mader, Matthias; Hänsch, Theodor W; Hunger, David

    2014-01-01

    Imaging of the optical properties of individual nanosystems beyond fluorescence can provide a wealth of information. However, the minute signals for absorption and dispersion are challenging to observe, and only specialized techniques requiring sophisticated noise rejection are available. Here we use signal enhancement in a scanning optical microcavity to demonstrate ultra-sensitive imaging. Harnessing multiple interactions of probe light with a sample within an optical resonator, we achieve a 1700-fold signal enhancement compared to diffraction-limited microscopy. We demonstrate quantitative imaging of the extinction cross section of gold nanoparticles with a sensitivity below 1 nm2, we show a method to improve spatial resolution potentially below the diffraction limit by using higher order cavity modes, and we present measurements of the birefringence and extinction contrast of gold nanorods. The demonstrated simultaneous enhancement of absorptive and dispersive signals promises intriguing potential for opt...

  7. Micro scanning probes

    CERN Document Server

    Niblock, T

    2001-01-01

    This thesis covers the design methodology, theory, modelling, fabrication and evaluation of a Micro-Scanning-Probe. The device is a thermally actuated bimorph quadrapod fabricated using Micro Electro Mechanical Systems technology. A quadrapod is a structure with four arms, in this case a planar structure with the four arms forming a cross which is dry etched out of a silicon diaphragm. Each arm has a layer of aluminium deposited on it forming a bimorph. Through heating each arm actuation is achieved in the plane of the quadrapod and the direction normal to it. Fabrication of the device has required the development of bulk micromachining techniques to handle post CMOS fabricated wafers and the patterning of thickly sputtered aluminium in bulk micro machined cavities. CMOS fabrication techniques were used to incorporate diodes onto the quadrapod arms for temperature measurement of the arms. Fine tungsten and silicon tips have also been fabricated to allow tunnelling between the tip and the platform at the centr...

  8. CT scans in encephalitis

    International Nuclear Information System (INIS)

    Generally, CT scans reveal a decrease in the volume of the ventricular system, sylvian fissures and cortical sulci in the acute stage of encephalitis, and softening of the cerebral lobes with dilatation of the lateral ventricles and subarachnoidian dilated spaces in the chronic stage. We encountered three cases of encephalitis: mumps (case 1), herpes simplex (case 2), and syphilis (case 3). In case 1, brain edema was seen in the acute stage and brain atrophy in the chronic stage. In case 2, necrosis of the temporal pole, which is pathognomonic in herpes simplex encephalitis, was recognized. And in case 3, multiple lesions whose CT appearance was enhanced by contrast materials were found scattered over the whole brain. These lesions were diagnosed as inflammatory granuloma by histological examination. (author)

  9. SCAN: a Fortran syntax analyzer

    International Nuclear Information System (INIS)

    SCAN is a computer program which analyzes the syntax of a Fortran program. It reads statements of a Fortran program, checks the grammatical validity of them, and produces tables of the analyzed results and intermediate codes for further use. SCAN recognizes the Fortran syntax of the Japan Industrial Standards-7000, plus some Fortran-H statements. In this report, the structure of SCAN, the methods used by the SCAN to analyze statements, tables and intermediate Buckus form texts produced by the SCAN, are presented. The SCAN itself is also written in Fortran language and consists of about 5000 statements. By slight modifications the SCAN may be useful for any application which needs analysis operations of Fortran syntax. (author)

  10. Adaptive Fuzzy Backstepping Control against Actuator Faults

    Directory of Open Access Journals (Sweden)

    Fujiang Jin

    2011-01-01

    Full Text Available In this study, the problem of Fault-Tolerant Control (FTC for a class of uncertain nonlinear systems is studied. A novel FTC scheme is proposed to deal with both lock-in-place and loss of effectiveness faults of actuators. By employing fuzzy approximation and on-line adaptive updating, the proposed control scheme can tolerate the faults without detection and diagnosis mechanism. It is proved in theory that the FTC scheme can guarantee the closed-loop stability and desired output tracking performance in spite of all kinds of the faults and external disturbances. A simulation example is also included to show the effectiveness of the scheme.

  11. Computation of ion implantation uniformity

    International Nuclear Information System (INIS)

    Commercial ion implanters employ a variety of different systems to scan the ion beam over the target. In many of the target scanning systems employed the achievable uniformity of dose has been limited by the chosen geometry. This paper describes a computer program which has been used to calculate the dose uniformity of a number of these systems. The results are presented as iso-dose lines relative to the dose at the centre of the target. The non-uniformities are then directly apparent and the parameters controlling their magnitude can be readily considered by equipment designers, purchasers or users. (author)

  12. Radionuclide brain scanning

    International Nuclear Information System (INIS)

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  13. Gastrointestinal scanning agent

    International Nuclear Information System (INIS)

    An easily prepared radiolabeled gastrointestinal scanning agent is described. Technetium-99m has ideal characteristics for imaging the upper and lower GI tract and determining stomach emptying and intestinal transit time when used with an insoluble particulate material. For example, crystalline and amorphous calcium phosphate particles can be effectively labeled in a one-step process using sup(99m)TcO4 and SnCl2. These labeled particles have insignificant mass and when administered orally pass through the GI tract unchanged, without affecting the handling and density of the intestinal contents. Visualization of the esophageal entry into the stomach, the greater and lesser curvatures of the stomach, ejection into the duodenum, and rates of passage through the upper and lower GI tract are obtained. The slurry of sup(99m)TC particulate can be given rectally by enema. Good images of the cecum and the ascending, transverse, and descending colon are obtained. Mucosal folds and the splenic and hepatic flexures are visualized. The resilience of the large intestine is also readily visualized by pneumocolonographic techniques. (author)

  14. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  15. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Scanning apparatus is disclosed for use in computerized axial tomography systems. The apparatus includes an assembly rotatable about an axis extending along a central opening defined therein, and means for positioning the body portion to be examined within the central opening so that the axis of assembly rotation is perpendicular to a plane passing through the bodily structures to be examined. A source of penetrating radiation is mounted on the assembly toward one side thereof and provides radiation in the form of a fan beam. Detector means for the radiation are positioned on the assembly opposite the source, enabling detection of radiation which traverses laterally and is not absorbed in the thin body section in which the aforementioned plane resides. Means are provided for rotating the assembly so that the fan beam impinges upon said body portion at a plurality of incident directions. Signal processing and conditioning means mounted on the assembly and movable therewith, receive the output signals from the detector means and amplify and convert same to digital form. Slip ring interconnection means rotatable with the assembly, receive the outputs from the signal processors and conditioners and interfeed these signals to a computerized image reconstruction station. Slip rings rotatable with the assembly also provide interconnection enabling power and control inputs to the radiation source and to other portions of the apparatus. The assembly is continuously rotatable through successive 360 degree rotations and the examination sequence may be initiated at any point in the rotation of the assembly. The detector comprises an array of elements and means are provided for adjusting the gains of each channel associated with the individual detector elements as an incident of the examination process, thereby enabling compensation for drift in the channels

  16. Hyperchromatic laser scanning cytometry

    Science.gov (United States)

    Tárnok, Attila; Mittag, Anja

    2007-02-01

    In the emerging fields of high-content and high-throughput single cell analysis for Systems Biology and Cytomics multi- and polychromatic analysis of biological specimens has become increasingly important. Combining different technologies and staining methods polychromatic analysis (i.e. using 8 or more fluorescent colors at a time) can be pushed forward to measure anything stainable in a cell, an approach termed hyperchromatic cytometry. For cytometric cell analysis microscope based Slide Based Cytometry (SBC) technologies are ideal as, unlike flow cytometry, they are non-consumptive, i.e. the analyzed sample is fixed on the slide. Based on the feature of relocation identical cells can be subsequently reanalyzed. In this manner data on the single cell level after manipulation steps can be collected. In this overview various components for hyperchromatic cytometry are demonstrated for a SBC instrument, the Laser Scanning Cytometer (Compucyte Corp., Cambridge, MA): 1) polychromatic cytometry, 2) iterative restaining (using the same fluorochrome for restaining and subsequent reanalysis), 3) differential photobleaching (differentiating fluorochromes by their different photostability), 4) photoactivation (activating fluorescent nanoparticles or photocaged dyes), and 5) photodestruction (destruction of FRET dyes). With the intelligent combination of several of these techniques hyperchromatic cytometry allows to quantify and analyze virtually all components of relevance on the identical cell. The combination of high-throughput and high-content SBC analysis with high-resolution confocal imaging allows clear verification of phenotypically distinct subpopulations of cells with structural information. The information gained per specimen is only limited by the number of available antibodies and by sterical hindrance.

  17. Gallium scans in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Swick, H.M. (Univ. of Kentucky, Lexington); Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether /sup 67/Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on /sup 67/Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis. (HLW)

  18. Gallium scans in myasthenia gravis

    International Nuclear Information System (INIS)

    A study was conducted to determine whether 67Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on 67Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis

  19. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1995-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in STM I, these studies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described in chapters on scanning force microscopy, magnetic force microscopy, and scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Together, the two volumes give a comprehensive account of experimental aspects of STM. They provide essential reading and reference material for all students and researchers involved in this field. In this second edition the text has been updated and new methods are discussed.

  20. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1992-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in Vol. I, these sudies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described inchapters on scanning force microscopy, magnetic force microscopy, scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Togehter, the two volumes give a comprehensive account of experimental aspcets of STM. They provide essentialreading and reference material for all students and researchers involvedin this field.

  1. Bone Densitometry (Bone Density Scan)

    Science.gov (United States)

    ... of DXA Bone Densitometry? What is a Bone Density Scan (DXA)? Bone density scanning, also called dual-energy x-ray absorptiometry ( ... is today's established standard for measuring bone mineral density (BMD). An x-ray (radiograph) is a noninvasive ...

  2. Applications of EHD-ion sources in SIMS

    International Nuclear Information System (INIS)

    Because of their high brillance and their small energy spread EHD ion sources are well qualified for focused ion beams. This work describes the build-up and the main properties of a designed indium EHD ion source. It is used as primary gun in a scanning ion microprobe. The advantages of this new source instead of a O2 - duoplasmatron ion source are described and demonstrated by selected examples. (Author)

  3. Application for the On-line Isotope Mass Separator ISOLDE Facility: the Mass Scan

    CERN Document Server

    Sánchez-Conejo, Jorge

    2003-01-01

    The purpose of the Mass Scan Application is to scan the mass of the ion beam that passes through the GPS (General Purpose Separator) on the On-Line Isotope Mass Separator ISOLDE facility. The application has been developed in Java, making use of the Java Development Kit 1.4 and the PS Java environment.

  4. Lidar arc scan uncertainty reduction through scanning geometry optimization

    Directory of Open Access Journals (Sweden)

    H. Wang

    2015-10-01

    Full Text Available Doppler lidars are frequently operated in a mode referred to as arc scans, wherein the lidar beam scans across a sector with a fixed elevation angle and the resulting measurements are used to derive an estimate of the n minute horizontal mean wind velocity (speed and direction. Previous studies have shown that the uncertainty in the measured wind speed originates from turbulent wind fluctuations and depends on the scan geometry (the arc span and the arc orientation. This paper is designed to provide guidance on optimal scan geometries for two key applications in the wind energy industry: wind turbine power performance analysis and annual energy production. We present a quantitative analysis of the retrieved wind speed uncertainty derived using a theoretical model with the assumption of isotropic and frozen turbulence, and observations from three sites that are onshore with flat terrain, onshore with complex terrain and offshore, respectively. The results from both the theoretical model and observations show that the uncertainty is scaled with the turbulence intensity such that the relative standard error on the 10 min mean wind speed is about 30 % of the turbulence intensity. The uncertainty in both retrieved wind speeds and derived wind energy production estimates can be reduced by aligning lidar beams with the dominant wind direction, increasing the arc span and lowering the number of beams per arc scan. Large arc spans should be used at sites with high turbulence intensity and/or large wind direction variation when arc scans are used for wind resource assessment.

  5. Pott's disease: radioisotope scanning findings

    International Nuclear Information System (INIS)

    The study is aim was to describe findings in bone scan in patients with Pott's disease. Eight patients had a bone scan with 99mTc . The findings included: a spindle image due to increased uptake in vertebrae and intervertebral uptake in three cases, increased uptake in vertebrae in three cases, paravertebral uptake in one case and vertebral compression with diminished uptake in one case. Bone scan is a useful tool in evaluating spinal tuberculosis (Pott's disease) as an indicator of activity within the lesion. (authors)

  6. Gas and metal ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Oaks, E. [High Current Electronics Institute, Tomsk (Russian Federation)]|[State Academy of Control System and Radioelectronics, Tomsk (Russian Federation); Yushkov, G. [High Current Electronics Institute, Tomsk (Russian Federation)

    1996-08-01

    The positive ion sources are now of interest owing to both their conventional use, e.g., as injectors in charged-particle accelerators and the promising capabilities of intense ion beams in the processes related to the action of ions on various solid surfaces. For industrial use, the sources of intense ion beams and their power supplies should meet the specific requirements as follows: They should be simple, technologically effective, reliable, and relatively low-cost. Since the scanning of an intense ion beam is a complicated problem, broad ion beams hold the greatest promise. For the best use of such beams it is desirable that the ion current density be uniformly distributed over the beam cross section. The ion beam current density should be high enough for the treatment process be accomplished for an acceptable time. Thus, the ion sources used for high-current, high-dose metallurgical implantation should provide for gaining an exposure dose of {approximately} 10{sup 17} cm{sup {minus}2} in some tens of minutes. So the average ion current density at the surface under treatment should be over 10{sup {minus}5} A/cm{sup 2}. The upper limit of the current density depends on the admissible heating of the surface under treatment. The accelerating voltage of an ion source is dictated by its specific use; it seems to lie in the range from {approximately}1 kV (for the ion source used for surface sputtering) to {approximately}100 kV and over (for the ion sources used for high-current, high-dose metallurgical implantation).

  7. Ion Colliders

    CERN Document Server

    Fischer, W

    2014-01-01

    High-energy ion colliders are large research tools in nuclear physics to study the Quark-Gluon-Plasma (QGP). The range of collision energy and high luminosity are important design and operational considerations. The experiments also expect flexibility with frequent changes in the collision energy, detector fields, and ion species. Ion species range from protons, including polarized protons in RHIC, to heavy nuclei like gold, lead and uranium. Asymmetric collision combinations (e.g. protons against heavy ions) are also essential. For the creation, acceleration, and storage of bright intense ion beams, limits are set by space charge, charge change, and intrabeam scattering effects, as well as beam losses due to a variety of other phenomena. Currently, there are two operating ion colliders, the Relativistic Heavy Ion Collider (RHIC) at BNL, and the Large Hadron Collider (LHC) at CERN.

  8. Pediatric pulmonary CT-scanning

    International Nuclear Information System (INIS)

    Forty three lung scans, obtained in 29 anaesthetized children, were evaluated and compared with 85 scans performed in 52 sedated children. Confluent high absorptive areas in the lower parts of the lungs were found in 35 (81%) of the scans performed in children under general aneasthesia but such areas were not found in the scans performed under sedation. For general anaesthesia, halothane-N2O-O2 was used in all but one patient. The radiological changes are presumably due to a fall in functional residual capacity with consequent airway closure. It is important not to misinterpret these anaesthesia-induced pulmonary changes which may obscure or mimic true pathological lesions, such as parenchymal and pleural metastases. (orig.)

  9. Establishing an Environmental Scanning Process.

    Science.gov (United States)

    Morrison, James L.

    1985-01-01

    A formal environmental scanning system designed to identify emerging issues, events, or trends threatening or bringing opportunity to an institution is discussed that uses a committee to systematically collect and analyze data from a variety of sources. (MSE)

  10. Scanning electron microscopy of biomaterials

    OpenAIRE

    McKinlay, K.J.; Scotchford, C A; Grant, D M; Oliver, J M; King, John R.; Brown, Paul D.

    2004-01-01

    A comparison of conventional high vacuum scanning electron microscopy (HVSEM), environmental SEM (ESEM) and confocal laser scanning microscopy (CLSM) in the assessment of cell-material interactions is made. The processing of cells cultured for conventional HVSEM leads to the loss of morphological features that are retained when using ESEM. The use of ESEM in conjunction with CLSM of the labeled cytoskeleton gives an indication of changes to the cell morphology as a consequence of incubation t...

  11. Azimuthal scans in LEIS: Influence of the scattering potential

    Science.gov (United States)

    Andrzejewski, R.; Kuzmin, V.; Boerma, D. O.; Primetzhofer, D.; Markin, S. N.; Bauer, P.

    2009-02-01

    Angular scans were performed for a Cu(1 0 0) single crystal and 3 keV He+ ions. The results were compared to simulations using the Monte-Carlo code TRIC [R. Andrzejewski, Ph.D. thesis, Universidad Autonóma de Madrid, 2008; V.A. Khodyrev, R. Andrzejewski, A. Rivera, D.O. Boerma, J.E. Prieto, in press] to obtain information on the ion-atom interaction. Different potentials were used in the simulations, e.g. the Thomas-Fermi-Moliere potential with a modified screening length and a Hartree-Fock potential. It was found that the experimental results can be very well reproduced by use of two potentials that exhibit a significantly different distance dependence, when properly scaled. This leads to the conclusion that care must be taken when deducing a scattering potential from comparison of experimental and simulated azimuthal scans.

  12. Lidar arc scan uncertainty reduction through scanning geometry optimization

    Science.gov (United States)

    Wang, Hui; Barthelmie, Rebecca J.; Pryor, Sara C.; Brown, Gareth.

    2016-04-01

    Doppler lidars are frequently operated in a mode referred to as arc scans, wherein the lidar beam scans across a sector with a fixed elevation angle and the resulting measurements are used to derive an estimate of the n minute horizontal mean wind velocity (speed and direction). Previous studies have shown that the uncertainty in the measured wind speed originates from turbulent wind fluctuations and depends on the scan geometry (the arc span and the arc orientation). This paper is designed to provide guidance on optimal scan geometries for two key applications in the wind energy industry: wind turbine power performance analysis and annual energy production prediction. We present a quantitative analysis of the retrieved wind speed uncertainty derived using a theoretical model with the assumption of isotropic and frozen turbulence, and observations from three sites that are onshore with flat terrain, onshore with complex terrain and offshore, respectively. The results from both the theoretical model and observations show that the uncertainty is scaled with the turbulence intensity such that the relative standard error on the 10 min mean wind speed is about 30 % of the turbulence intensity. The uncertainty in both retrieved wind speeds and derived wind energy production estimates can be reduced by aligning lidar beams with the dominant wind direction, increasing the arc span and lowering the number of beams per arc scan. Large arc spans should be used at sites with high turbulence intensity and/or large wind direction variation.

  13. Ion colliders

    International Nuclear Information System (INIS)

    Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions (77Asb1, 81Bou1). The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the

  14. Sub-Kelvin scanning tunneling microscopy on magnetic molecules

    OpenAIRE

    Zhang, Lei

    2012-01-01

    Magnetic molecules have attracted lots interest. In this work, an ultra-stable and low noise scanning tunneling microscopy operating at 400 mK using He-3 (930 mK using He-4) has been developed. The magnetic behavior of different magnetic molecules on substrates, especially the exchange interaction between the magnetic ions, the magnetic anisotropy on the surface, the magnetic excitations as well as the Kondo effect, were studied by using STM.

  15. Hepatobiliary scan in neonatal Jaundice

    International Nuclear Information System (INIS)

    Jaundice is more or less common in newborn babies. Through physiological jaundice is most common cause of neonatal jaundice, possibility of obstructive jaundice especially biliary atresia should be kept in mind. Early diagnosis of biliary atresia followed by surgical treatment can save baby's life. Otherwise death is inevitable due to liver failure. Hepatobiliary scan is the imaging study of choice in neonatal jaundice especially when there is persistent conjugated hyperbilirubinaemia. Total 27 newborn babies of suspected biliary atresia, aged 14 days to 4 months were referred to Institute of Nuclear Medicine for Hepatobiliary scan. All of them had high serum bilirubin ranged from 6.0 mg/dl with an average of 9.35 ng/dl serum bilirubin level. Ultrasonography of hepatobiliary system was performed in 14 cases showing normal sized liver in 4 cases and hepatomegaly in 10 cases. Hepatobiliary scan was done with 99mTc-Mebrofenin (Br IDA) after preparing the baby with phenobarbitone for 3-5 days. 20 (67%) cases were scan positive suggesting biliary atresia (BA) and 7(27%) cases were scan negative. In BA there will be increased hepatic uptake of the radionuclide without any significant excretion even in 24 hours delayed images. Presence of radiotracer in the bowel exclude the diagnosis of BA. Early diagnosis of biliary atresia is very important because in this condition surgery should be performed early (within 60 days of life). Studies suggest that hepatobiliary scan after hepatic stimulation with phenobarbitone for a period of 3-5 days is highly accurate for differentiating biliary atresia from other causes of neonatal jaundice. It is very important to perform hepatobiliary scan in a case of neonatal jaundice to exclude biliary atresia for the sake of baby's life.(author)

  16. Environmental Scanning and the Information Manager.

    Science.gov (United States)

    Newsome, James; McInerney, Claire

    1990-01-01

    Discusses nine components of an environmental scanning model: selecting the scanning team; selecting resources to scan; choosing criteria for scanning; scanning the resources; identifying signals of new issues; selecting key events/issues; monitoring and analyzing events/issues; disseminating information; and deciding on appropriate organizational…

  17. Elimination technique for alkali metal ion adducts from an electrospray ionization process using an on-line ion suppressor

    OpenAIRE

    NOZAKI, Kazuyoshi; TARUI, Akira; OSAKA, Issey; Kawasaki, Hideya; ARAKAWA, Ryuichi; 荒川, 隆一

    2010-01-01

    The effects of an on-line ion suppressor device on alkali metal ion adduct formations of the model compound tacrolimus were investigated. The base peak ion in the positive ion ESI-MS spectrum of tacrolimus was a sodium ion adduct, [M+Na]+. On the other hand, an ammonium ion adduct, [M+NH4]+, was the base peak ion in the full-scan mass spectrum of tacrolimus with a cation-exchange suppressor resin, and both [M+Na]+ and [M+K]+ were eliminated. These results indicate that the combination of an o...

  18. Holders for in situ treatments of scanning tunneling microscopy tips

    International Nuclear Information System (INIS)

    We have developed holders for scanning tunneling microscopy tips that can be used for in situ treatments of the tips, such as electron bombardment (EB) heating, ion sputtering, and the coating of magnetic materials. The holders can be readily installed into the transfer paths and do not require any special type of base stages. Scanning electron microscopy is used to characterize the tip apex after EB heating. Also, spin-polarized scanning tunneling spectroscopy using an Fe coated W tip on the Cr(001) single crystal surface is performed in order to confirm both the capability of heating a tip up to about 2200 K and the spin sensitivity of the magnetically coated tip.

  19. Air-ion counter and mobility spectrometer

    International Nuclear Information System (INIS)

    Mono-electrode self “zeroing” air-ion counter and mobility (size) scanning spectrometer (CDI-011) based on the Gerdien aspirated condenser principle has been developed. Instrument is intended for short- and long-term indoor and outdoor air-ion concentration measurements and scanning of air-ions by mobility. Measuring small currents (typically 10−14 A) generated by the air-ions in outdoor conditions is demanding and causes many problems related to change of temperature, relative humidity, wind and electromagnetic noise. Also, measuring of both ion polarities with mono electrode detector require alternate changes of the polarizing voltage sign which produces capacitive current spikes. Various techniques, including “zeroing” method, have been applied to successfully overcome most of these measuring interferences.

  20. Air-ion counter and mobility spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kolarz, Predrag, E-mail: kolarz@ipb.ac.rs [Institute of Physics, University of Belgrade, Pregrevica 118, 11080 Belgrade (Serbia); Miljkovic, Budimir [Merni Instrumenti D.O.O., Ljube Stojanovica 38, 11000 Belgrade (Serbia); Curguz, Zoran [Faculty of Transport and Traffic Engineering, University of East Sarajevo, Vojvode Misica 52, 74000 Doboj (Bosnia and Herzegowina)

    2012-05-15

    Mono-electrode self 'zeroing' air-ion counter and mobility (size) scanning spectrometer (CDI-011) based on the Gerdien aspirated condenser principle has been developed. Instrument is intended for short- and long-term indoor and outdoor air-ion concentration measurements and scanning of air-ions by mobility. Measuring small currents (typically 10{sup -14} A) generated by the air-ions in outdoor conditions is demanding and causes many problems related to change of temperature, relative humidity, wind and electromagnetic noise. Also, measuring of both ion polarities with mono electrode detector require alternate changes of the polarizing voltage sign which produces capacitive current spikes. Various techniques, including 'zeroing' method, have been applied to successfully overcome most of these measuring interferences.

  1. Interesting bone scans - unusual findings

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, M.; Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B. [Wollongong Hospital, Wollongong, NSW (Australia)

    1997-12-01

    A 59-year-old female with carcinoma of the colon and known liver metastatic disease was referred for bone scan to evaluate for bone metastases. Although no bone metastases were found, there was abnormal uptake noted in the liver corresponding to a metastatic calcified lesion. The only other findings were of degenerative disease in the cervical spine, right shoulder and small joints of the hands. A 69-year-old male with carcinoma of the prostate and right side low back pain was referred for bone scan. No focal abnormalities to suggest metastatic disease were identified; findings within the cervical spine, lumber spine and knees were presumed secondary to degenerative disease. Intermittent pain persisted and the patient was referred for a repeat bone scan six months later. Previous scan findings of degenerative disease and no metastatic disease were confirmed; however, closer inspection revealed an enlarged right kidney with significant retention of tracer in the pelvicalyceal system suggesting possible obstruction. A Retrograde pyelogram was performed, and no obvious obstruction demonstrated. As bone scan findings were very suggestive of obstruction, a DTPA scan with lasix was performed showing a dilated right collecting system with no functional obstruction. Given the degree of dilation, it is possible that the patient experiences intermittent PUJ obstruction causing his symptoms. A 33-year-old male with insulin dependent diabetes mellitus and viral arthritis was referred for a bone scan. A three phase revealed increased uptake in the region of the knee and leR proximal tibia. Delayed whole body images revealed multiple focal areas of osteoblastic activity in the leR tibia. Abnormal uptake was also seen in the upper third of the leR femur. The remainder of the skeletal survey was normal. X-ray correlation of the leR tibia and femoral findings was undertaken. Combinating unilateral changes on bone scan and X-ray although very suggestive of sclerotic polyostotic

  2. Interesting bone scans - unusual findings

    International Nuclear Information System (INIS)

    A 59-year-old female with carcinoma of the colon and known liver metastatic disease was referred for bone scan to evaluate for bone metastases. Although no bone metastases were found, there was abnormal uptake noted in the liver corresponding to a metastatic calcified lesion. The only other findings were of degenerative disease in the cervical spine, right shoulder and small joints of the hands. A 69-year-old male with carcinoma of the prostate and right side low back pain was referred for bone scan. No focal abnormalities to suggest metastatic disease were identified; findings within the cervical spine, lumber spine and knees were presumed secondary to degenerative disease. Intermittent pain persisted and the patient was referred for a repeat bone scan six months later. Previous scan findings of degenerative disease and no metastatic disease were confirmed; however, closer inspection revealed an enlarged right kidney with significant retention of tracer in the pelvicalyceal system suggesting possible obstruction. A Retrograde pyelogram was performed, and no obvious obstruction demonstrated. As bone scan findings were very suggestive of obstruction, a DTPA scan with lasix was performed showing a dilated right collecting system with no functional obstruction. Given the degree of dilation, it is possible that the patient experiences intermittent PUJ obstruction causing his symptoms. A 33-year-old male with insulin dependent diabetes mellitus and viral arthritis was referred for a bone scan. A three phase revealed increased uptake in the region of the knee and leR proximal tibia. Delayed whole body images revealed multiple focal areas of osteoblastic activity in the leR tibia. Abnormal uptake was also seen in the upper third of the leR femur. The remainder of the skeletal survey was normal. X-ray correlation of the leR tibia and femoral findings was undertaken. Combinating unilateral changes on bone scan and X-ray although very suggestive of sclerotic polyostotic

  3. The boundary-scan handbook

    CERN Document Server

    Parker, Kenneth P

    2016-01-01

    Aimed at electronics industry professionals, this 4th edition of the Boundary Scan Handbook describes recent changes to the IEEE1149.1 Standard Test Access Port and Boundary-Scan Architecture. This updated edition features new chapters on the possible effects of the changes on the work of the practicing test engineers and the new 1149.8.1 standard. Anyone needing to understand the basics of boundary scan and its practical industrial implementation will need this book. Provides an overview of the recent changes to the 1149.1 standard and the effect of the changes on the work of test engineers;   Explains the new IEEE 1149.8.1 subsidiary standard and applications;   Describes the latest updates on the supplementary IEEE testing standards. In particular, addresses: IEEE Std 1149.1                      Digital Boundary-Scan IEEE Std 1149.4                      Analog Boundary-Scan IEEE Std 1149.6                      Advanced I/O Testing IEEE Std 1149.8.1           �...

  4. What Is a Nuclear Heart Scan?

    Science.gov (United States)

    ... from the NHLBI on Twitter. What Is a Nuclear Heart Scan? A nuclear heart scan is a test that provides important ... use it to create pictures of your heart. Nuclear heart scans are used for three main purposes: ...

  5. Calculation of Uniform of Beam Scanning

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    For the electron beam application, it is always scanned by a dipole magnet. The uniform of the scanning has great influence for some application, such as the irradiation of the thyristor. There are two methods for improving the scanning uniform:

  6. Linking world scan and image

    International Nuclear Information System (INIS)

    In march 1994 the Central Planning Bureau (CPB) in the Hague, the National Institute of Public Health and Environmental Protection (RIVM) in Bilthoven and the Institute of Environmental Studies (IES) in Amsterdam started the first phase of a joint research program aimed at creating integrated scenarios of the global economy, GHG emissions, and climate impacts. The goal of the first phase of this project was to design and test a linked version of the economic model WORLD SCAN of the former, and the climate model IMAGE 2 of the latter institute. This first phase has resulted in the planned test runs with an operational version of the linked models by May 1995. The experiences in the first year were encouraging, both in the scientific and the organizational sense. In a sense, a link was made between scientific disciplines: a coupling of disciplines concerning with global economic development and the global physical climate system is difficult and novel. The goal of the project was to integrate long-term economic developments and effects of climate change. Both the WORLD SCAN model and IMAGE 2 provide a consistent analysis of the global system, but from different perspectives. IMAGE 2 simulates climate change and its effects in a global context but treats the economic system as exogenous. WORLD SCAN covers the world economic system in a consistent manner but does not take into account the global environment. The links are constructed in the area of agriculture and energy. The basic idea is that WORLD SCAN determines demand and supply on economic principles, while IMAGE 2 provides information on changes of land area and average quality of productive land, and other damage costs based on its three sub-systems. The demand for energy is fed into IMAGE 2's Energy Industry subsystem (EIS), which in turn determines emissions of greenhouse gases. Furthermore, some additional output from WORLD SCAN on activity levels, prices and capital structure can be used to determine

  7. Children, CT Scan and Radiation

    OpenAIRE

    Morteza Bajoghli; Farshad Bajoghli; Nazila Tayari; Reza Rouzbahani

    2010-01-01

    Children are more sensitive to radiation than adults. Computer-ized tomography (CT) consists of 25 % of all medical imaging. It was estimated that more than 2% of all carcinomas in the USA are due to CT scans. There is an ongoing focus on the reduction of CT scan radiation dose. Awareness about risk-benefits of CT has increased. Reduction of radiological exam is an important issue because the accumulation effects of radiation can be hazardous. In addition, proper protocol should be followed f...

  8. RPC High Voltage Scan 2015

    CERN Document Server

    CMS Collaboration

    2016-01-01

    During the LS1 the CMS RPC system has been upgraded with 144 new chambers installed on the forth endcap stations. An annual HV (RPC efficiency vs HV) scan for the entire RPC system has been performed during the Run2 data taking period in 2015. The obtained results have been compared to the HV scans performed in 2011 and 2012. No significant differences are observed in the compared results. The optimal HV working points for the newly installed chambers have been evaluated for the first time with collision data.

  9. Producing colour pictures from SCAN

    International Nuclear Information System (INIS)

    The computer code SCAN.TSK has been written for use on the Interdata 7/32 minicomputer which will convert the pictures produced by the SCAN program into colour pictures on a colour graphics VDU. These colour pictures are a more powerful aid to detecting errors in the MONK input data than the normal lineprinter pictures. This report is intended as a user manual for using the program on the Interdata 7/32, and describes the method used to produce the pictures and gives examples of JCL, input data and of the pictures that can be produced. (U.K.)

  10. Multifunction Digital Research Scanning System

    International Nuclear Information System (INIS)

    The multifunction digital research scanning system is a modularly constructed organ visualization system. The design objective of this system is quantification of organ visualization data, i.e. μCi/g. It is a high-speed (500 cm/min), 14-crystal, digital rectilinear scanner built as a special-purpose hard-wired computer. The two synchronous detector heads, one beneath and one above the scantable, each consisting of a linear array of seven, 3-in. x 2-in. NaI(Tl) crystals, each crystal having its own focused collimator. Each 7-detector array can be independently moved in the vertical direction. The exact position of the detectors is known at all times by the use of an absolute 13-bit shaft angle encoder along the longitudinal axis of the scantable and a programmable SloSyn motor across the table. Anatomical landmarks may be programmed into the system and automatically recognized when the detector passes over these points. The scan field is 198 cm long by 62 cm wide with a position resolution of 0.14 cm. The primary scan motion is along the longitudinal axis of the table and the detectors are indexed across the table. The scan image is built up seven lines at a time, allowing the total scanfield to be visualized with each pass of the detectors. Each crystal has its own 8-bit or 12-bit counter with buffer storage. A single fast pulse-height analyser (200 nsec. random pulse-pair resolution) is used for all 14 crystals using a time-sharing 'cueing' technique. The major components of the system consist of the mechanical scanning frame and position encoders; radiation detectors, coincidence circuitry and nuclear instrumentation; counters and buffer storage; anatomical landmark recognition section; arithmetic section; program control logic; system control logic; output control logic and the output devices. At present, the output devices consist of digital cathode-ray tubes, a storage scope, an IBM l/O writer and a Kennedy incremental read-write magnetic tape recorder. This

  11. Ion Chromatography.

    Science.gov (United States)

    Mulik, James D.; Sawicki, Eugene

    1979-01-01

    Accurate for the analysis of ions in solution, this form of analysis enables the analyst to directly assay many compounds that previously were difficult or impossible to analyze. The method is a combination of the methodologies of ion exchange, liquid chromatography, and conductimetric determination with eluant suppression. (Author/RE)

  12. Localizing Test Power Consumption for Scan Testing

    Institute of Scientific and Technical Information of China (English)

    XIANG Dong; LI Kai-wei

    2005-01-01

    A two stage scan architecture is proposed to do low powerand low test application cost scan testing. The first stage includes multiple scan chains, where each scan chain is driven by a primary input. Each scan flip-flop in the multiple scan chains drives a group of scan flip-flops. The scan flip-flop in the multiple scan chain and the scan flipflop driven by it are assigned the same values for all test vectors. Scan flip-flops in the multiple scan chains and those in the second stage use separate clock signals, but the design for testability technqiue needs only one clock. The proposed scan architecture localizes test power consumption to the multiple scan chains during test application. Test signals assigned to scan flip-flops in the multiple scan chains are applied to the scan flip-flops in the second stage after the test vector has been applied to the multiple scan chains. This technique can make test power consumption very small.

  13. A quadrupole ion trap as low-energy cluster ion beam source

    CERN Document Server

    Uchida, N; Kanayama, T

    2003-01-01

    Kinetic energy distribution of ion beams was measured by a retarding field energy analyzer for a mass-selective cluster ion beam deposition system that uses a quadrupole ion trap as a cluster ion beam source. The results indicated that the system delivers a cluster-ion beam with energy distribution of approx 2 eV, which corresponded well to the calculation results of the trapping potentials in the ion trap. Using this deposition system, mass-selected hydrogenated Si cluster ions Si sub n H sub x sup + were actually deposited on Si(111)-(7x7) surfaces at impact kinetic energy E sub d of 3-30 eV. Observation by using a scanning tunneling microscope (STM) demonstrated that Si sub 6 H sub x sup + cluster ions landed on the surface without decomposition at E sub d =3 eV, while the deposition was destructive at E sub d>=18 eV. (author)

  14. Broadband antenna with frequency scanning

    Directory of Open Access Journals (Sweden)

    A. A. Shekaturin

    2014-06-01

    Full Text Available Relevance of this study. The main advantage of frequency scanning is simplicity of implementation. At this point, multifunctional usage of microwave modules is an urgent task, as well as their maximum simpler and cheaper. Antenna design and operation. The study is aimed at providing electric antenna with frequency scanning. It was based on the log-periodic antenna due to its wideband and negotiation capability over the entire operating frequency range. For this distribution line is bent in an arc of a circle in a plane blade while vibrators are arranged along the radius. Computer modeling of antennas with frequency scanning. Modeled with a non-mechanical motion antenna beam emitters representing system for receiving a radio frequency signal on mobile objects calculated for 1.8 GHz ... 4.2 GHz. The simulation was performed in a software environment for numerical modeling of electromagnetic «Feko 5.5». Analysis of the interaction of radiation is based on the method of moments. Findings. The result of this work is to propose a new design of the antenna with a frequency scanning method as agreed in a wide frequency range. In the studied technical solution provided by the rotation of NAM in the frequency range, and the matching of the antenna to the feed line is maintained. Application of this type of antennas on the proposed technical solution in communication systems will improve the communication reliability by maintaining coordination in the frequency range

  15. Introduction to scanning tunneling microscopy

    CERN Document Server

    Chen, C Julian

    2008-01-01

    The scanning tunneling and the atomic force microscope, both capable of imaging individual atoms, were crowned with the Physics Nobel Prize in 1986, and are the cornerstones of nanotechnology today. This is a thoroughly updated version of this 'bible' in the field.

  16. Pulmonary ventilation/perfusion scan

    Science.gov (United States)

    ... Critical Care, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the A.D.A.M. Editorial team. Related MedlinePlus Health Topics COPD Lung Diseases Nuclear Scans Pulmonary Embolism Browse the Encyclopedia A.D. ...

  17. Developing an Environmental Scanning System.

    Science.gov (United States)

    Morrison, James L.

    A step-by-step approach is provided for developing an environmental scanning system for colleges and universities to assist them in planning for the future. The objectives of such a system are to detect social, scientific, economic, technical, and political interactions important to the organization; define potential threats and opportunities from…

  18. Environmental Scanning, Vancouver Community College.

    Science.gov (United States)

    Yao, Min

    This 1994 environmental scanning report from Vancouver Community College (VCC) reviews the expected effects of the separation of VCC into a new Vancouver Community College and Langara College (LC). The report examines the projected service area student-intake capacity; student characteristics; population growth trends; other postsecondary…

  19. CT scan of Parkinson's disease

    International Nuclear Information System (INIS)

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs. (author)

  20. Single ion cavity QED experiments

    International Nuclear Information System (INIS)

    Full text: We have set up a spherical Paul trap for a storing a single Ca+ ion placed in the center of a high finesse near confocal resonator. We report on experiments demonstrating the coupling of the narrow S1/2-D5/2 transition to the cavity internal light field. Due to the coupling, the ion acts as sensitive probe for the cavity internal field. We are able to map the field distribution by measuring the excitation probability. Scanning the cavity over the resonance imprints a Doppler frequency shift on the cavity field which leads to a spectral shift and a asymmetric broadening of the S-D transition. (author)

  1. Ion implantation

    International Nuclear Information System (INIS)

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  2. Heavy ions: Report from Relativistic Heavy Ion Collider

    Indian Academy of Sciences (India)

    Sonia Kabana

    2012-10-01

    We review selected highlights from the experiments at the Relativistic Heavy Ion Collider (RHIC) exploring the QCD phase diagram. A wealth of new results appeared recently from RHIC due to major recent upgrades, like for example the $\\Upsilon$ suppression in central nucleus-nucleus collisions which has been discovered recently in both RHIC and LHC. Furthermore, we discuss RHIC results from the beam energy scan (BES) program aiming to search for a possible critical point and to map out the QCD phase diagram.

  3. Ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Tarter, J.G.

    1987-01-01

    Similar in many ways to other liquid chromatographic techniques, ion chromatography (IC) is an invaluable method that is used all too rarely in chemical analysis. Its application is particularly promising in the analysis of inorganic anions, an area where more information is needed. Ion Chromatogrphy identifies the merits of this technique. Serving as a review and reference for experienced ion chromatographers and as a teaching aid for individuals new to the field, it provides the information necessary for determining the potential usefulness of IC for a given situation. Among the areas treated, this volume focuses on eluant-suppressed IC, especially for anion and cation analysis, single-column IC, plus ancillary techniques and applications, electrochemical, spectroscopic, and other detecting methods, ion chromatography exclusion (ICE), including its limits and applications.

  4. Children, CT scan and radiation

    Directory of Open Access Journals (Sweden)

    Morteza Bajoghli

    2010-01-01

    Full Text Available Children are more sensitive to radiation than adults. Computer-ized tomography (CT consists of 25 % of all medical imaging. It was estimated that more than 2% of all carcinomas in the USA are due to CT scans. There is an ongoing focus on the reduction of CT scan radiation dose. Awareness about risk-benefits of CT has increased. Reduction of radiological exam is an important issue because the accumulation effects of radiation can be hazardous. In addition, proper protocol should be followed for diagnostic pro-cedures of ionization radiation and computerized tomography. Effective radiation dose should range from 0.8 to 10.5 millisievert. The same protocol should be followed in different hospitals as well. Basic principles of radiation protection should be monitored. As much as possible, both technician and radiologist must be pre-sent during computerized tomography for children, and MRI and ultrasound should be replaced if possible.

  5. /sup 67/Ga lung scan

    Energy Technology Data Exchange (ETDEWEB)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-03-21

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate /sup 67/Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the /sup 67/Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of /sup 67/Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of /sup 67/Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography.

  6. A Laser Scanning Tracking Method

    Science.gov (United States)

    Xu, Gaoyue; Hu, Baoli; Wang, Jiangping

    1988-04-01

    In this paper, a new tracking approach, a laser scanning tracking method (LSTM) is proposed. The LSTM has been designed to track a cylindrical retroreflective target mounted on the object, which makes plane motion. The retroreflector pasted by scotchlite reflective sheeting (mad. in 3M ,0.) i s located by scanning a laser beam in holizontal. When the retroreflector is struck, its position that is azimuth is read by microcomputer and the aiming device is servocontrolled by microcomputer according to this azimuth immediately. This is a step-by-step tracking method. The time of servo-reponse is less than one millisecona in actual tests. The angular accuracy is less than 0.5 milliradian. The track angular velocity is greater than one radian/second.

  7. Automation of BESSY scanning tables

    International Nuclear Information System (INIS)

    A micro processor M6800 is used for the automation of scanning and premeasuring BESSY tables. The tasks achieved by the micro processor are: 1. control of spooling of the four asynchronous film winding devices and switching on and off the 4 projections lamps, 2. pre-processing of the data coming from a bi-polar coordinates measuring device, 3. bi-directional interchange of informations between the operator, the BESSY table and the DEC PDP 11/34 mini computer controling the scanning operations, 4. control of the magnification on the table by swapping the projection lenses of appropriate focal lengths and the associated light boxes (under development). In connection with point 4, study is being made for the use of BESSY tables for accurate measurements (+/-5 microns), by encoding the displacements of the projections lenses. (orig.)

  8. Seismic scanning tunneling macroscope - Theory

    KAUST Repository

    Schuster, Gerard T.

    2012-09-01

    We propose a seismic scanning tunneling macroscope (SSTM) that can detect the presence of sub-wavelength scatterers in the near-field of either the source or the receivers. Analytic formulas for the time reverse mirror (TRM) profile associated with a single scatterer model show that the spatial resolution limit to be, unlike the Abbe limit of λ/2, independent of wavelength and linearly proportional to the source-scatterer separation as long as the point scatterer is in the near-field region; if the sub-wavelength scatterer is a spherical impedance discontinuity then the resolution will also be limited by the radius of the sphere. Therefore, superresolution imaging can be achieved as the scatterer approaches the source. This is analogous to an optical scanning tunneling microscope that has sub-wavelength resolution. Scaled to seismic frequencies, it is theoretically possible to extract 100 Hz information from 20 Hz data by imaging of near-field seismic energy.

  9. First PET scans in Estonia

    International Nuclear Information System (INIS)

    First PET scans in Estonia were performed on 25th November 2002 in North Estonia Regional Hospital, Tallinn. Six patients with melanoma underwent scanning with FDG. This event was a result of thorough extensive preparations first started in 2000 during the European Association of Nuclear Medicine congress in Paris. During the congress first contacts were made with providers of mobile PET units. At the same time negotiations were begun with potential FDG suppliers. For the introduction of PET in Estonia mobile truckmounted scanning technology was chosen due to low level of initial investments. Of particular importance was also availability of maintenance personnel from the device providers. A significant prerequisite was potential availability of FDG from the neighbourhood - Finland and Sweden. The latter avoided the necessity for investments into local cyclotrons and local FDG production. For the first scanning experience the dedicated truckmounted PET-camera Accel, Siemens was brought by the International Hospital Group (IHG, Amersfoort, Netherlands). The device arrived by ferry from Stockholm to Tallinn harbour at 10 o'clock in the morning and left by ferry for Helsinki at 23 o'clock. The team-on-truck consisted of one technician for device operation, two drivers and two company representatives. North Estonia Regional Hospital provided three additional technicians for patient preparation and FDG injection, one nuclear medicine doctor and one specialist of biomedical engineering and medical physics. The FDG was provided by MAP Medical Technologies, Schering, Helsinki, Finland. The shipments were made by air. This was possible due to small distance between Tallinn and Helsinki of approximately 80 km due to the regular flight connections between the two cities. The FDG was shipped in two lots with a time interval of 4 hours. The patient selection was based on clinical and histopathology data. In all six patients the exam was justified for detailied staging and

  10. 3D scanning with Kinect

    OpenAIRE

    Novak, David

    2012-01-01

    This paper describes the procedures and technologies used for scanning and three-dimensional reconstruction of objects using the optical scanner Kinect. Theoretical backgrounds of basic computer graphics, projective geometry, optics and graphical reconstruction were studied for better understanding of this field of computer science. A part of the content also describes the structure and operating of the Kinect and is used as a theoretical basis for implementing a new framework for three-di...

  11. Differential scanning calorimetry of coal

    Science.gov (United States)

    Gold, P. I.

    1978-01-01

    Differential scanning calorimetry studies performed during the first year of this project demonstrated the occurrence of exothermic reactions associated with the production of volatile matter in or near the plastic region. The temperature and magnitude of the exothermic peak were observed to be strongly affected by the heating rate, sample mass and, to a lesser extent, by sample particle size. Thermal properties also were found to be influenced by oxidation of the coal sample due to weathering effects.

  12. Automatic scanning for nuclear emulsion

    International Nuclear Information System (INIS)

    Automatic scanning systems have been recently developed for application in neutrino experiments exploiting nuclear emulsion detectors of particle tracks. These systems speed up substantially the analysis of events in emulsion, allowing the realisation of experiments with unprecedented statistics. The pioneering work on automatic scanning has been done by the University of Nagoya (Japan). The so called new track selector has a very good reproducibility in position (∼1 μm) and angle (∼3 mrad), with the possibility to reconstruct, in about 3 s, all the tracks in a view of 150x150 μm2 and 1 mm of thickness. A new system (ultratrack selector), with speed higher by one order of magnitude, has started to be in operation. R and D programs are going on in Nagoya and in other laboratories for new systems. The scanning speed in nuclear emulsion be further increased by an order of magnitude. The recent progress in the technology of digital signal processing and of image acquisition systems (CCDs and fast frame grabbers) allows the realisation of systems with high performance. New interesting applications of the technique in other fields (e.g. in biophysics) have recently been envisaged

  13. New Snail Mail Scanning Service

    CERN Multimedia

    2012-01-01

    Modernisation does not stop at the CERN postal service (GS/PS). “With more and more digitisation and the prevalence of e-mail throughout the site, we were hoping to provide more timely delivery of letters and make further saving in resources”, said Tueri Datta, head of GS/PS.   Instead of the standard delivery to your P.O. box, the CERN postal service will digitally scan all letters and books up to 100 pages on reception. These scans will subsequently be sent via e-mail to the corresponding recipient as PDF (Portable Data Format - you will need to install “Acrobat Reader” on your PC). Express mail will be handled with priority. Users without a valid CERN mailbox can register at mail.scan.service@cern.ch in order to have their letters read to them via the phone line (we are currently investigating whether we can use the voices of the last five DGs).   This service will start on 1st April 2012 on the Meyrin site and will gradually replace th...

  14. Noncontact scanning electrical impedance imaging.

    Science.gov (United States)

    Liu, Hongze; Hawkins, Aaron; Schultz, Stephen; Oliphant, Travis E

    2004-01-01

    We are interested in applying electrical impedance imaging to a single cell because it has potential to reveal both cell anatomy and cell function. Unfortunately, classic impedance imaging techniques are not applicable to this small scale measurement due to their low resolution. In this paper, a different method of impedance imaging is developed based on a noncontact scanning system. In this system, the imaging sample is immersed in an aqueous solution allowing for the use of various probe designs. Among those designs, we discuss a novel shield-probe design that has the advantage of better signal-to-noise ratio with higher resolution compared to other probes. Images showing the magnitude of current for each scanned point were obtained using this configuration. A low-frequency linear physical model helps to relate the current to the conductivity at each point. Line-scan data of high impedance contrast structures can be shown to be a good fit to this model. The first two-dimensional impedance image of biological tissues generated by this technique is shown with resolution on the order of 100 mum. The image reveals details not present in the optical image. PMID:17271930

  15. A Plasma Ion Source for ISOLTRAP

    CERN Document Server

    Skov, Thomas Guldager

    2016-01-01

    In this report, my work testing the new Penning ion source as a summer student at ISOLTRAP is described. The project was composed of three stages: (1) Setting up a test laboratory in building 275, (2) characterizing the ion source, and (3) implementing and testing the source in the ISOLTRAP setup. After setting up the test laboratory, the ion source was tested in a constant pressure environment with produced ion currents in the range of nA . An extensive scan of the source ion current versus operating parameters (pressure, voltage) was performed. A setup with pulsed gas flow was also tested, allowing a reduction of the gas load on the vacuum system. The behavior of the ion source together with the ISOLTRAP setup was also investigated, allowing to understand current limitations and future directions of improvement.

  16. Diagnosis of spatial resolution for microbeam scanning PIXE using STIM method and CR-39 track detector in PASTA

    International Nuclear Information System (INIS)

    In PIXE analysis system and Tandem Accelerator facility (PASTA) of NIRS, we are using Scanning Transmission Ion Microscopy (STIM) method and solid track detector to diagnose the spatial resolution of scanning microbeam PIXE analysis system. These methods are widely used by many microbeam facilities. (author)

  17. Probing cytotoxicity of nanoparticles and organic compounds using scanning proton microscopy, scanning electron microscopy and fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tong Yongpeng [Institute of Nuclear Techniques, Shenzhen University, Nanhai Avenue 3688, Shenzhen 518060 (China)], E-mail: yongpengt@yahoo.com.cn; Li Changming [School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637457 (Singapore); Liang Feng [Institute Pasteur of Shanghai, Chinese Academy of Sciences, Shanghai 200025 (China); Chen Jianmin [Shenzhen Municipal Hospital for Chronic Disease Control and Prevention, Guangdong 518020 (China); Zhang Hong; Liu Guoqing; Sun Huibin [Institute of Nuclear Techniques, Shenzhen University, Nanhai Avenue 3688, Shenzhen 518060 (China); Luong, John H.T. [Biotechnology Research Institute, National Research Council Canada, Montreal, Quebec, H4P 2R2 (Canada)

    2008-12-15

    Scanning proton microscopy, scanning electron microscopy (SEM) and fluorescence microscopy have been used to probe the cytotoxicity effect of benzo[a]pyrene (BaP), ethidium bromide (EB) and nanoparticles (ZnO, Al{sub 2}O{sub 3} and TiO{sub 2}) on a T lymphoblastic leukemia Jurkat cell line. The increased calcium ion (from CaCl{sub 2}) in the culture medium stimulated the accumulation of BaP and EB inside the cell, leading to cell death. ZnO, Al{sub 2}O{sub 3} and TiO{sub 2} nanoparticles, however, showed a protective effect against these two organic compounds. Such inorganic nanoparticles complexed with BaP or EB which became less toxic to the cell. Fe{sub 2}O{sub 3} nanoparticles as an insoluble particle model scavenged by macrophage were investigated in rats. They were scavenged out of the lung tissue about 48 h after infection. This result suggest that some insoluble inorganic nanoparticles of PM (particulate matters) showed protective effects on organic toxins induced acute toxic effects as they can be scavenged by macrophage cells. Whereas, some inorganic ions such as calcium ion in PM may help environmental organic toxins to penetrate cell membrane and induce higher toxic effect.

  18. Probing cytotoxicity of nanoparticles and organic compounds using scanning proton microscopy, scanning electron microscopy and fluorescence microscopy

    International Nuclear Information System (INIS)

    Scanning proton microscopy, scanning electron microscopy (SEM) and fluorescence microscopy have been used to probe the cytotoxicity effect of benzo[a]pyrene (BaP), ethidium bromide (EB) and nanoparticles (ZnO, Al2O3 and TiO2) on a T lymphoblastic leukemia Jurkat cell line. The increased calcium ion (from CaCl2) in the culture medium stimulated the accumulation of BaP and EB inside the cell, leading to cell death. ZnO, Al2O3 and TiO2 nanoparticles, however, showed a protective effect against these two organic compounds. Such inorganic nanoparticles complexed with BaP or EB which became less toxic to the cell. Fe2O3 nanoparticles as an insoluble particle model scavenged by macrophage were investigated in rats. They were scavenged out of the lung tissue about 48 h after infection. This result suggest that some insoluble inorganic nanoparticles of PM (particulate matters) showed protective effects on organic toxins induced acute toxic effects as they can be scavenged by macrophage cells. Whereas, some inorganic ions such as calcium ion in PM may help environmental organic toxins to penetrate cell membrane and induce higher toxic effect.

  19. Information Theory and Radioisotope Scanning

    International Nuclear Information System (INIS)

    The quality of a scintigram is often described in terms of resolution and contrast. Generally, these two parameters are not independent of each other. Increased resolution can usually only be achieved at the cost of decreased contrast. A fundamental problem in scanning theory is to find the best compromise between resolution and contrast. This problem can be solved if one can find a measure of the quality of a scintigram that considers both resolution and contrast. This paper discusses the possibility of defining the information content of a scintigram and using this as a quality measure. First, an elementary introduction to information theory is presented in order to enable a reader with no previous knowledge of information theory to follow the rest of the paper. A heuristic approach to the main topic is criticized and some commonly met pitfalls during the application of the information theory are pointed out. A mathematical model of a simplified scanning system consisting of a collimator and a detector is described. The amount of information available at the output of this system is calculated. The scanning system divides the scintigram into a number of image elements. With few image elements the contrast is good. If the number of elements is increased resolution is improved, but contrast is reduced. It can be shown that, under certain conditions, as the number of elements is increased the amount of information in the image first increases, reaches a maximum and then decreases. A discussion follows on how much of the potentially available information is lost in the display system, for instance through the effect of contrast enhancement. Finally, it is pointed out that high information content is a necessary, but not sufficient, condition for good quality of a scintigram. (author)

  20. ABS: Sequence alignment by scanning

    KAUST Repository

    Bonny, Mohamed Talal

    2011-08-01

    Sequence alignment is an essential tool in almost any computational biology research. It processes large database sequences and considered to be high consumers of computation time. Heuristic algorithms are used to get approximate but fast results. We introduce fast alignment algorithm, called Alignment By Scanning (ABS), to provide an approximate alignment of two DNA sequences. We compare our algorithm with the well-known alignment algorithms, the FASTA (which is heuristic) and the \\'Needleman-Wunsch\\' (which is optimal). The proposed algorithm achieves up to 76% enhancement in alignment score when it is compared with the FASTA Algorithm. The evaluations are conducted using different lengths of DNA sequences. © 2011 IEEE.

  1. Low energy ion beam dynamics of NANOGAN ECR ion source

    Science.gov (United States)

    Kumar, Sarvesh; Mandal, A.

    2016-04-01

    A new low energy ion beam facility (LEIBF) has been developed for providing the mass analyzed highly charged intense ion beams of energy ranging from a few tens of keV to a few MeV for atomic, molecular and materials sciences research. The new facility consists of an all permanent magnet 10 GHz electron cyclotron resonance (ECR) ion source (NANOGAN) installed on a high voltage platform (400 kV) which provides large currents of multiply charged ion beams. Higher emittance at low energy of intense ion beam puts a tremendous challenge to the beam optical design of this facility. The beam line consists of mainly the electrostatic quadrupoles, an accelerating section, analyzing cum switching magnet and suitable beam diagnostics including vacuum components. The accelerated ion beam is analyzed for a particular mass to charge (m/q) ratio as well as guided to three different lines along 75°, 90° and 105° using a large acceptance analyzing cum switching magnet. The details of transverse beam optics to all the beam lines with TRANSPORT and GICOSY beam optics codes are being described. Field computation code, OPERA 3D has been utilized to design the magnets and electrostatic quadrupoles. A theoretical estimation of emittance for optimized geometry of ion source is given so as to form the basis of beam optics calculations. The method of quadrupole scan of the beam is used to characterize the emittance of the final beam on the target. The measured beam emittance increases with m/q ratios of various ion beams similar to the trend observed theoretically.

  2. Plasma etching of superconducting Niobium tips for scanning tunneling microscopy

    International Nuclear Information System (INIS)

    We have developed a reproducible technique for the fabrication of sharp superconducting Nb tips for scanning tunneling microscopy (STM) and scanning tunneling spectroscopy. Sections of Nb wire with 250 μm diameter are dry etched in an SF6 plasma in a Reactive Ion Etcher. The gas pressure, etching time, and applied power are chosen to control the ratio of isotropic to anisotropic etch rates and produce the desired tip shape. The resulting tips are atomically sharp, with radii of less than 100 nm, mechanically stable, and superconducting. They generate good STM images and spectroscopy on single crystal samples of Au(111), Au(100), and Nb(100), as well as a doped topological insulator Bi2Se3 at temperatures ranging from 30 mK to 9 K.

  3. Scanning laser mass spectrometry for trace level solute concentration profiles

    International Nuclear Information System (INIS)

    Scanning laser mass spectrometry (SLMS) is shown to support solid-state studies of migration of trace level solutes in solids. SLMS possesses the spatial chemical analysis capabilities necessary for these studies. Nuclides present in the solid specimen at less than 10 parts-per-million atomic (ppMa) are measured accurately with ordinary Faraday ion detectors. Spatial resolution for these studies is on the order of 25 to 50 μm. Quantification is demonstrated with standards where a relative deviation of a mean calibration factor is 1.6%. Scanning samples are achieved by sequential stepping or by a dynamic measuring technique. Several different solutes and solid matrices are measured concerned with actual solid-state experiments involving electric mobility and chemical diffusion

  4. The Kv channel blocker 4-aminopyridine enhances Ag+ uptake: A scanning electrochemical microscopy study of single living cells

    OpenAIRE

    Zhan, Dongping; Fan, Fu-Ren F.; Bard, Allen J.

    2008-01-01

    We report that silver ion (Ag+) uptake is enhanced by 4-aminopyridine (4-AP), a well known voltage-sensitive potassium ion channel (Kv) blocker. Both bacterial (Escherichia coli) and mammalian (3T3 fibroblast) cells were used as model systems. Ag+ uptake was monitored with a scanning electrochemical microscope with an amperometric Ag+ ion-selective electrode (Ag+-ISE) and the respiration rates of E. coli cells were measured by oxygen reduction at an ultramicroelectrode. The results showed tha...

  5. Observation of molybdenite surface using scanning Auger microscope

    Science.gov (United States)

    Takagi, S.; Murakami, K.; Gotoh, T.

    1999-04-01

    A preliminary experiment was performed on diffusion of gas particles in the bulk to the surface using the electron stimulated desorption (ESD) method. In molybdenite diffusion of hydrogen from the bulk to the surface was observed by desorbed ion images in the scanning electron microscope. Diffusion to the surface was observed on two types of surface, those with high step density and those with lower density, at about 300 and 400°C of the sample temperatures. The diffusion energy from the bulk to the surface can be larger than the thermal desorption energy at the surface.

  6. A design for a pinhole scanning helium microscope

    International Nuclear Information System (INIS)

    We present a simplified design for a scanning helium microscope (SHeM) which utilises almost entirely off the shelf components. The SHeM produces images by detecting scattered neutral helium atoms from a surface, forming an entirely surface sensitive and non-destructive imaging technique. This particular prototype instrument avoids the complexities of existing neutral atom optics by replacing them with an aperture in the form of an ion beam milled pinhole, resulting in a resolution of around 5 microns. Using the images so far produced, an initial investigation of topological contrast has been performed

  7. CDMP Scan Task Production Flow Sheets

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Climate Database Modernization Program contractor documentation of batches scanned. Details include the name of the operator, time/date of scans, duplicates,...

  8. Using Environmental Scans in Educational Needs Assessment.

    Science.gov (United States)

    Hatch, Terry F.; Pearson, Thomas G.

    1998-01-01

    Presents advantages and disadvantages of environmental scanning for assessing the context of professional continuing education. Provides a checklist for evaluating the quality and usefulness of information sources. Addresses the ethics of scanning. (SK)

  9. A collection of Schottky-scan notes

    International Nuclear Information System (INIS)

    This paper is a republication of ISR-RF notes and performance reports on work done in 1974-1975. The original notes have been edited, corrected and, in most cases, shortened. Discussed in this note are the following topics: noise, errors and the Schottky scan; speeding up the Schottky scan; Schottky markers and fast Schottky scans; and some engineering aspects of the fast Schottky scan

  10. Probabilistic sonar scan matching for an AUV

    OpenAIRE

    Hernàndez Bes, Emili; Ridao Rodríguez, Pere; Ribas Romagós, David; Mallios, Angelos

    2009-01-01

    This paper proposes MSISpIC, a probabilistic sonar scan matching algorithm for the localization of an autonomous underwater vehicle (AUV). The technique uses range scans gathered with a Mechanical Scanning Imaging Sonar (MSIS), the robot displacement estimated through dead-reckoning using a Doppler velocity log (DVL) and a motion reference unit (MRU). The proposed method is an extension of the pIC algorithm. An extended Kalman filter (EKF) is used to estimate the robot-path during the scan in...

  11. Immobilization of DNA for scanning probe microscopy.

    OpenAIRE

    Allison, D. P.; Bottomley, L A; T. Thundat; Brown, G M; Woychik, R. P.; Schrick, J. J.; Jacobson, K B; Warmack, R J

    1992-01-01

    Reproducible scanning tunneling microscope and atomic force microscope images of entire molecules of uncoated plasmid DNA chemically bound to surfaces are presented. The chemically mediated immobilization of DNA to surfaces and subsequent scanning tunneling microscope imaging of DNA molecules demonstrate that the problem of molecular instability to forces exerted by the probe tip, inherent with scanning probe microscopes, can be prevented.

  12. Issue Scanning: Finding the Future...Maybe.

    Science.gov (United States)

    Plog, Michael; Sweeney, Jim; Weiss, Barry

    Issue Scanning, sometimes called Environmental Scanning, is used in many business, government, educational, and nonprofit organizations. The technique is supposed to monitor the "pulse" of the external environment. The scanning process should lessen the randomness of the information used in decision making, and it should alert managers to trends…

  13. Ion beam deposition of calcium hydroxyapatite

    International Nuclear Information System (INIS)

    Calcium hydroxyapatite has been sputtered on glass and Ti-6Al-4V substrates using a 1.5 kV argon ion beam. The films have been examined by X- ray diffraction analysis, energy dispersive spectroscopy, scanning electron microscopy, and adhesion testing. Results of this experimentation are presented

  14. Optical contrast in ion-implanted amorphous silicon carbide nanostructures

    International Nuclear Information System (INIS)

    Topographic and optical contrasts formed by Ga+ ion irradiation of thin films of amorphous silicon carbide have been investigated with scanning near-field optical microscopy. The influence of ion-irradiation dose has been studied in a pattern of sub-micrometre stripes. While the film thickness decreases monotonically with ion dose, the optical contrast rapidly increases to a maximum value and then decreases gradually. The results are discussed in terms of the competition between the effects of ion implantation and surface milling by the ion beam. The observed effects are important for uses of amorphous silicon carbide thin films as permanent archives in optical data storage applications

  15. QUANTITATIVE CONFOCAL LASER SCANNING MICROSCOPY

    Directory of Open Access Journals (Sweden)

    Merete Krog Raarup

    2011-05-01

    Full Text Available This paper discusses recent advances in confocal laser scanning microscopy (CLSM for imaging of 3D structure as well as quantitative characterization of biomolecular interactions and diffusion behaviour by means of one- and two-photon excitation. The use of CLSM for improved stereological length estimation in thick (up to 0.5 mm tissue is proposed. The techniques of FRET (Fluorescence Resonance Energy Transfer, FLIM (Fluorescence Lifetime Imaging Microscopy, FCS (Fluorescence Correlation Spectroscopy and FRAP (Fluorescence Recovery After Photobleaching are introduced and their applicability for quantitative imaging of biomolecular (co-localization and trafficking in live cells described. The advantage of two-photon versus one-photon excitation in relation to these techniques is discussed.

  16. Scanning Probe Microscopy of Graphene

    Science.gov (United States)

    Tautz, Pamela

    2011-10-01

    Scanning tunneling microscopy has been used to study the unusual electronic properties of graphene. In an effort to support the graphene with minimal interaction with the substrate, we used a hexagonal boron nitride (hBN) substrate. To minimize contaminants between the CVD graphene and boron nitride, the graphene samples were cleaned with distilled water and isopropanol prior to transfer to hBN substrate. We have also examined the growth of graphene flakes by chemical vapor deposition. In particular, we examined the relationship between the orientations of the first and second layer of CVD grown graphene. We found the growth mechanism preferentially resulted in rotations of 9^o or less indicating flakes with first and second layers aligned.

  17. A fluorescence scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Takaaki Kanemaru

    2010-01-01

    Full Text Available Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM and an electron microscope (EM. In the current study, a scanning electron microscope (SEM (JEOL JXA8600 M was combined with a fluorescence digital camera microscope unit and this hybrid instrument was named a fluorescence SEM (FL-SEM. In the labeling of FL-SEM samples, both Fluolid, which is an organic EL dye, and Alexa Fluor, were employed. We successfully demonstrated that the FL-SEM is a simple and practical tool for correlative fluorescence and electron microscopy.

  18. Scanning ARM Cloud Radar Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Widener, K; Bharadwaj, N; Johnson, K

    2012-06-18

    The scanning ARM cloud radar (SACR) is a polarimetric Doppler radar consisting of three different radar designs based on operating frequency. These are designated as follows: (1) X-band SACR (X-SACR); (2) Ka-band SACR (Ka-SACR); and (3) W-band SACR (W-SACR). There are two SACRs on a single pedestal at each site where SACRs are deployed. The selection of the operating frequencies at each deployed site is predominantly determined by atmospheric attenuation at the site. Because RF attenuation increases with atmospheric water vapor content, ARM's Tropical Western Pacific (TWP) sites use the X-/Ka-band frequency pair. The Southern Great Plains (SGP) and North Slope of Alaska (NSA) sites field the Ka-/W-band frequency pair. One ARM Mobile Facility (AMF1) has a Ka/W-SACR and the other (AMF2) has a X/Ka-SACR.

  19. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili

    2007-09-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 {micro}m-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance

  20. Plasma ion sources and ion beam technology in microfabrications

    International Nuclear Information System (INIS)

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 (micro)m-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance

  1. The utility of bone scans in rheumatology

    International Nuclear Information System (INIS)

    Full text: Introduction: Bone scans are the commonest diagnostic imaging services requested by Australian rheumatologists. Medicare figures suggest that an average rheumatologist orders about $50 000 (AUS) of bone scans annually. Aims: To ascertain the reasons why rheumatologists request bone scans and how it affects their patient management. Methods: A two-part prospective survey was administered before and after every bone scan ordered by four rheumatologists over a six-month period in 1996. Results: A total of 136 bone scans were requested (66.2% whole body; 33.8% regional; 6% SPECT). The primary indications for scanning were (1) to confirm a clinical diagnosis (38%); (2) to exclude a diagnosis (34%); (3) to localize site of pain (17%); and (4) to assist in management (6%). The common diseases that rheumatologists were attempting to confirm/exclude with bone scanning were inflammatory arthritis, malignancy, and fracture. However, the commonest provisional and final diagnosis was soft tissue rheumatism (18%) followed by inflammatory arthritis (15%) and osteoarthritis (11%). In 24% of patients with a provisional diagnosis of soft tissue rheumatism the diagnosis was changed by the bone scan. The scan was successful in excluding a diagnosis in 88 per cent where this was the primary indication for the test. It was successful in confirming a diagnosis in 79 per cent where this was the primary indication. In 32 per cent the bone scan altered the clinical diagnosis and in 43 per cent it altered management. The bone scan result prevented further investigations in 60 per cent. Conclusions: The commonest pre-scan and post-scan diagnosis is soft tissue rheumatism. Rheumatologists predominantly request bone scanning to confirm or exclude their clinical suspicion of inflammatory arthritis, malignancy, and fracture. Bone scans were successful in achieving these objectives in at least 79 per cent of cases

  2. Selective Measurement of Calcium and Sodium Ion Conductance Using Sub-Micropipette Probes with Ion Filters

    Science.gov (United States)

    Deng, Xiao Long; Takami, Tomohide; Son, Jong Wan; Kawai, Tomoji; Park, Bae Ho

    2012-02-01

    Selective ion currents in aqueous calcium chloride and sodium chloride solutions with concentrations of up to 1.0 M were observed with sub-micropipettes in which poly(vinyl chloride) (PVC) films containing ionophores selectively filtered cations. Calcium bis[4-(1,1,3,3-tetramethylbutyl)phenyl] phosphate (HDOPP-Ca) and bis[(12-crown-4)methyl]-2-dodecyl-2-methylmalonate [bis(12-crown-4)] were used as the ionophores to filter calcium and sodium ions, respectively. The selective ion current was observed using a low-current detection system developed from scanning tunneling microscopy. The approximate linear relationship between the ion concentration and ion current suggests that the sub-micropipette probe can be used to detect the intracellular local concentration of a specific ion up to 1.0 M.

  3. Singularity and Bohm criterion in hot positive ion species in the electronegative ion sources

    Science.gov (United States)

    Aslaninejad, Morteza; Yasserian, Kiomars

    2016-05-01

    The structure of the discharge for a magnetized electronegative ion source with two species of positive ions is investigated. The thermal motion of hot positive ions and the singularities involved with it are taken into account. By analytical solution of the neutral region, the location of the singular point and also the values of the plasma parameter such as electric potential and ion density at the singular point are obtained. A generalized Bohm criterion is recovered and discussed. In addition, for the non-neutral solution, the numerical method is used. In contrast with cold ion plasma, qualitative changes are observed. The parameter space region within which oscillations in the density and potential can be observed has been scanned and discussed. The space charge behavior in the vicinity of edge of the ion sources has also been discussed in detail.

  4. Handbook of optical and laser scanning

    CERN Document Server

    Marshall, Gerald F

    2011-01-01

    From its initial publication titled Laser Beam Scanning in 1985 to Handbook of Optical and Laser Scanning, now in its second edition, this reference has kept professionals and students at the forefront of optical scanning technology. Carefully and meticulously updated in each iteration, the book continues to be the most comprehensive scanning resource on the market. It examines the breadth and depth of subtopics in the field from a variety of perspectives. The Second Edition covers: Technologies such as piezoelectric devices Applications of laser scanning such as Ladar (laser radar) Underwater

  5. The Microstructure of Tool Steel after Low Temperature Ion Nitriding

    OpenAIRE

    Zagonel, L. F.; Mittemeijer, E. J.; Alvarez, F.

    2012-01-01

    The microstructural development in H13 tool steel upon nitriding by an ion beam process was investigated. The nitriding experiments were performed at a relatively low temperature of about 400\\deg C and at constant ion beam energy (400 eV) of different doses in a high-vacuum preparation chamber; the ion source was fed with high purity nitrogen gas. The specimens were characterized by X-ray photoelectron spectroscopy (XPS), electron probe microanalysis (EPMA), scanning and transmission electron...

  6. Development of heavy-ion irradiation technique for single-event in semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Norio; Akutsu, Takao; Matsuda, Sumio [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Naitoh, Ichiro; Itoh, Hisayoshi; Agematsu, Takashi; Kamiya, Tomihiro; Nashiyama, Isamu

    1997-03-01

    Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

  7. Bone scanning in severe external otitis

    Energy Technology Data Exchange (ETDEWEB)

    Levin, W.J.; Shary, J.H. 3d.; Nichols, L.T.; Lucente, F.E.

    1986-11-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis.

  8. Bone scanning in severe external otitis

    International Nuclear Information System (INIS)

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis

  9. Controllable Laser Ion Acceleration

    Science.gov (United States)

    Kawata, S.; Kamiyama, D.; Ohtake, Y.; Takano, M.; Barada, D.; Kong, Q.; Wang, P. X.; Gu, Y. J.; Wang, W. M.; Limpouch, J.; Andreev, A.; Bulanov, S. V.; Sheng, Z. M.; Klimo, O.; Psikal, J.; Ma, Y. Y.; Li, X. F.; Yu, Q. S.

    2016-02-01

    In this paper a future laser ion accelerator is discussed to make the laser-based ion accelerator compact and controllable. Especially a collimation device is focused in this paper. The future laser ion accelerator should have an ion source, ion collimators, ion beam bunchers, and ion post acceleration devices [Laser Therapy 22, 103(2013)]: the ion particle energy and the ion energy spectrum are controlled to meet requirements for a future compact laser ion accelerator for ion cancer therapy or for other purposes. The energy efficiency from the laser to ions is improved by using a solid target with a fine sub-wavelength structure or a near-critical density gas plasma. The ion beam collimation is performed by holes behind the solid target or a multi-layered solid target. The control of the ion energy spectrum and the ion particle energy, and the ion beam bunching would be successfully realized by a multistage laser-target interaction.

  10. ION VATAMANU

    Directory of Open Access Journals (Sweden)

    l. Povar

    2012-12-01

    Full Text Available Ion Vatamanu was a chemist, writer and public figure. He was equally passionate about both his chosen fields of activity: chemistry and poetry. Chemistry, with its perfect equilibrium of logic and precision, provided inspiration for lyrical creativity, whereas poetry writing enlivened his imagination and passion for chemistry. He loved his parents. He adored his wife Elena, whom he often gifted a sea of flowers. He loved his daughters Mihaela, Mariana, and Leontina. He loved life, and he loved people.

  11. Heavy ion radiotherapy. Yesterday, today and tomorrow

    International Nuclear Information System (INIS)

    At EO Lawrence Berkeley National Laboratory (LBNL), clinical trials were conducted (1975-1992) for treating human cancer using heavy ion beams, in which about 700 patients were treated with helium-ion and about 300 patients with neon-ion beams. Clinical trials at the Gesellschaft fur Schwerionenforschung (GSI) in Darmstadt, Germany used carbon-ion beams to treat about 250 patients (1997-2005). In 1993 the National Institute of Radiological Sciences (NIRS) in Chiba, Japan, commissioned its first-in-the-world medicallydedicated Heavy Ion Medical Accelerator in Chiba (HIMAC), which accelerates heavy ions to an energy of 800 MeV/u (million electron volts per nucleon). By 2010 more than 5000 patients have been treated using carbon-ion beams at HIMAC. Following its successful clinical operation, several carbon-ion therapy facilities have been, or will be soon, constructed in: Hyogo (commissioned in 2001) and Gunma (2010), Japan; Heidelberg (2009), Marburg (2010) and Kiel (2012), Germany; Pavia (2010), Italy; Lyon (2015), France; Wiener Neustadt (2015), Austria; Shanghai (2015) and Lanzhou, China; and Busan (2016), Korea. Very active clinical research and technology development projects are carried out at these institutions to enhance beam delivery accuracy, such as beam scanning that compensates for organ movements, which will further improve the clinical efficacy of the ion-beam therapy in the future. (author)

  12. Verification of high efficient broad beam cold cathode ion source.

    Science.gov (United States)

    Abdel Reheem, A M; Ahmed, M M; Abdelhamid, M M; Ashour, A H

    2016-08-01

    An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition. PMID:27587108

  13. Ion Beam Extraction by Discrete Ion Focusing

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (900) and methods are disclosed for ion beam extraction. In an implementation, the apparatus includes a plasma source (or plasma) (802) and an ion extractor (804). The plasma source is adapted to generate ions and the ion extractor is immersed in the plasma source to extract a fraction......) in the space-charge surrounding the ion extractor. The strongly curved potential distribution focuses the extracted ions towards an opening (814) on a surface of the biased electrode thereby resulting in an ion beam....... of the generated ions. The ion extractor is surrounded by a space charge (810) formed at least in part by the extracted ions. The ion extractor includes a biased electrode (806) forming an interface with an insulator (808). The interface is customized to form a strongly curved potential distribution (812...

  14. Scanning Tunneling Optical Resonance Microscopy

    Science.gov (United States)

    Bailey, Sheila; Wilt, Dave; Raffaelle, Ryne; Gennett, Tom; Tin, Padetha; Lau, Janice; Castro, Stephanie; Jenkins, Philip; Scheiman, Dave

    2003-01-01

    Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically < 10 Hz) that the

  15. The INTEGRAL Galactic Plane Scanning

    CERN Document Server

    Fiocchi, Mariateresa

    2013-01-01

    After the first nine years of INTEGRAL operational life, the discovery of new sources and source types, a large fraction of which are highly transient or highly absorbed, is certainly one of the most compelling results and legacies of INTEGRAL. Frequent monitoring of the Galactic Plane in AO8 and AO9 campaigns allowed us to detect transient sources, both known and new, confirming that the gamma-ray sky is dominated by the extreme variability of different classes of objects. Regular scans of the Galactic Plane by INTEGRAL provide the most sensitive hard X-ray wide survey to date of our Galaxy, with flux limits of the order of 0.3 mCrab for an exposure time of ~2Ms. Many transient sources have been detected on a wide range of time scales (~hours to months) and identified by triggered followup observations, mainly by Swift/XRT and optical/infrared telescopes. These discoveries are very important to characterize the X-ray binary population in our Galaxy, that is necessary input for evolution studies. The transien...

  16. Monochromated scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Full text: Electron energy-loss spectroscopy (EELS) has developed into an established technique for chemical and structural analysis of thin specimens in the (scanning) transmission electron microscope (S)TEM. The energy resolution in EELS is largely limited by the stability of the high voltage supply, by the resolution of the spectrometer and by the energy spread of the source. To overcome this limitation a Wien filter monochromator was recently introduced with commercially available STEMs, offering the advantage to better resolve EELS fine structures, which contain valuable bonding information. The method of atomic resolution Z-contrast imaging within an STEM, utilizing a high-angle annular dark-field (HAADF) detector can perfectly complement the excellent energy resolution, since EELS spectra can be collected simultaneously. In combination with a monochromator microscope not only high spatial resolution images can be recorded but also high energy resolution EELS spectra are attainable. In this work we investigated the STEM performance of a 200 kV monochromated Tecnai F20 with a high resolution Gatan Imaging Filter (HR-GIF). (author)

  17. CT scanning: patterns of use and dose

    International Nuclear Information System (INIS)

    CT scanning is a relatively high-dose procedure. In spite of the use of magnetic resonance imaging, with faster CT scanners and helical techniques CT is becoming more common. There are few data from practice in the United States regarding the age and sex distribution of patients receiving CT scans, what type of scan and how many scans they receive, or how much radiation dose CT scans contribute. We reviewed over 33 700 consecutive CT examinations done at our institution in 1998 and 1999. Information on the types of scans as well as the age and sex distribution of the patients was determined. Between 1990 and 1999, CT examinations in our institution increased from 6.1% to 11.1% of all radiology procedures. Nineteen per cent of all patients seen in our department in the last year had at least one CT scan and more than half had multiple scans on the same day. Thirty-six per cent of all patients had a prior CT examination done on an earlier date. The male/female ratio of patients was 56/44. Studies of children age 0-15 years comprised 11.2% of scans. The highest percentage of scans was done in the 36-50-year-old age group. CT scanning accounted for 67% of the effective dose from diagnostic radiology. In most large hospitals in the United States CT scanning probably accounts for more than 10% of diagnostic radiology examinations and about two-thirds of the radiation dose. Most patients have multiple scan sequences. Studies done on children are probably more common than previously thought. (author)

  18. Maskless, resistless ion beam lithography

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Qing

    2003-03-10

    are presented. The formation of shallow pn-junctions in bulk silicon wafers by scanning focused P{sup +} beam implantation at 5 keV is also presented. With implantation dose of around 10{sup 16} cm{sup -2}, the electron concentration is about 2.5 x 10{sup 18} cm{sup -3} and electron mobility is around 200 cm{sup 2}/V{center_dot}s. To demonstrate the suitability of scanning FIB lithography for the manufacture of integrated circuit devices, SOI MOSFET fabrication using the maskless, resistless ion beam lithography is demonstrated. An array of microcolumns can be built by stacking multi-aperture electrode and insulator layers. Because the multicusp plasma source can achieve uniform ion density over a large area, it can be used in conjunction with the array of microcolumns, for massively parallel FIB processing to achieve reasonable exposure throughput.

  19. Maskless, resistless ion beam lithography

    International Nuclear Information System (INIS)

    As the dimensions of semiconductor devices are scaled down, in order to achieve higher levels of integration, optical lithography will no longer be sufficient for the needs of the semiconductor industry. Alternative next-generation lithography (NGL) approaches, such as extreme ultra-violet (EUV), X-ray, electron-beam, and ion projection lithography face some challenging issues with complicated mask technology and low throughput. Among the four major alternative NGL approaches, ion beam lithography is the only one that can provide both maskless and resistless patterning. As such, it can potentially make nano-fabrication much simpler. This thesis investigates a focused ion beam system for maskless, resistless patterning that can be made practical for high-volume production. In order to achieve maskless, resistless patterning, the ion source must be able to produce a variety of ion species. The compact FIB system being developed uses a multicusp plasma ion source, which can generate ion beams of various elements, such as O2+, BF2+, P+ etc., for surface modification and doping applications. With optimized source condition, around 85% of BF2+, over 90% of O2+ and P+ have been achieved. The brightness of the multicusp-plasma ion source is a key issue for its application to maskless ion beam lithography. It can be substantially improved by optimizing the source configuration and extractor geometry. Measured brightness of 2 keV He+ beam is as high as 440 A/cm2 · Sr, which represents a 30x improvement over prior work. Direct patterning of Si thin film using a focused O2+ ion beam has been investigated. A thin surface oxide film can be selectively formed using 3 keV O2+ ions with the dose of 1015 cm-2. The oxide can then serve as a hard mask for patterning of the Si film. The process flow and the experimental results for directly patterned poly-Si features are presented. The formation of shallow pn-junctions in bulk silicon wafers by scanning focused P+ beam implantation at

  20. The scanning microbeam PIXE analysis facility at NIRS

    International Nuclear Information System (INIS)

    In March 1999, a HVEE Tandetron was installed in the Electrostatic Accelerator Building of National Institute of Radiological Sciences (NIRS) for particle induced X-ray emission (PIXE) analysis. The specifications of the Tandetron accelerator system operating at NIRS are as follows: the accelerating voltage is 0.4-1.7 MV, and the maximum beam current is 500 nA at 3.4 MeV. The accelerator facility incorporates three beam lines for conventional, in-air and microbeam PIXE analysis. The scanning microbeam PIXE analysis line is based around an Oxford Microbeams OM2000 nuclear microscope end stage. This system provides the ability of multi-elemental mapping over sample areas up to 2 x 2 mm area with spatial resolutions routinely at 1 x 1 μm. The scheduled operation of this facility started in April 2000 and is controlled by the Division of Technical Service and Development. The result of beam resolution tests carried out in 2001 are as follows: for scanning transmission ion microscopy, the estimated beam size is 100 x 200 nm, measured using a 2.6 MeV proton beam scanned over a 12.7 μm repeat distance copper grid. For PIXE operation at 50 pA beam current the estimated best spot size is 0.4 x 0.6 μm. The microbeam facility is being used for research into the elemental distribution of small biological samples such as biological cells and tissue

  1. method and container for production of diagnostic scanning agents

    International Nuclear Information System (INIS)

    The pertechnetate ion containing the technetium-99m isotope has limited applications in diagnostic scanning because it does not readily form complexes with materials which locate in specific parts of the body. Stannous salts have been widely used to reduce the pertechnetate to a form which readily complexes with materials. In the present invention, both a container and a more suitable metal reducing agent are discussed for transforming the technetium in pertechnetate for diagnostic scanning use. The vessel contains tin or a tin-containing alloy as a reducing agent for the pertechnetate and a complexant for the reduced technetium; all contents are sterile and dry. The present invention is advantageous over the stannous salts method since (1) problems of stannous salt instability during production, storage and after labelling are eliminated; (2) production procedures are simplified; (3) it is not essential to nitrogen purge vials before sterilisation; (4) it reduces toxicity; (5) the shelf life of diagnostic scanning kits may be dramatically improved; (6) the metal reducing agent may be sterilised by γ-irradiation without deteriorating; (7) the labelling technique can be performed over a wide pH range; and (8) the technique should be unaffected by technetium-99 in the technetium-99m. (U.K.)

  2. Diagnostic trials using CT scanning in urology

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, T. (Fujita Gakuen Univ., Toyoake, Aichi (Japan). School of Medicine)

    1981-07-01

    We attempted various new diagnostic trials using CT scanning. The results obtained were: 1) Twelve transplanted kidneys were scanned after bolus contrast administration. Enhancing indices (EI) calculated from the formula: EI = (CT numbers 10 minutes after injection) / (CT numbers before injection) were inversely proportional to serum creatinine. 2) CT guided puncture was successful in percutaneous nephrostomy in 3 of 5 cases of obstructive uropathy and in 5 cases of renal cystic disease. 3) Emergent CT scans were diagnostically useful in 9 cases of urinary tract injury to indicate surgery. 4) CT scans after perivesical pneumography in 5 cases of vesical tumor diclosed perivesical invasion. 5) Cervical CT scans were performed as a localization study of parathyroid gland in 3 cases of secondary hyperparathyroidism in chronic renal insufficiency. More than 1400 mg of parathyroid gland in the neck was clearly visualized on cervical CT scans.

  3. Modulation transfer function of bar code scanning

    Science.gov (United States)

    Tang, Hong; Milster, Tom D.

    1998-09-01

    Bar code scanners are ubiquitous in supermarkets. As a bar code is passed over a scanner, a laser beam scans across the bar code. The scattered light is modulated by the reflectivity of the bars and spaces of the bar code. The bar code scanning process can be described as a 1D convolution of the scanning laser profile and the bar code reflectivity function. The modulation transfer function (MTF) of bar code scanning is the Fourier transform of the marginal profile of the laser beam. The properties of the MTF of bar code scanning is similar to that of an incoherent imaging system. Measurements of the MTF of bar code scanning at one focus position are presented. The experimental results are then discussed.

  4. Observation of Liver Color Scan

    International Nuclear Information System (INIS)

    In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permitted a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscesses, 10 hepatitis and other 13 cases of the liver diseases which were clinically and pathologically diagnosed at Severance Hospital, Yonsei Univ. since Feb. 1969 through Sept. 1969. These scintigrams have been analyzed in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1) Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2) Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3) Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4) The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases (74-95% of all diseased livers). 5) The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6) Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape an margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  5. Human Digital Modeling & Hand Scanning Lab

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory incorporates specialized scanning equipment, computer workstations and software applications for the acquisition and analysis of digitized models of...

  6. Scanning Tunneling Microscope For Use In Vacuum

    Science.gov (United States)

    Abel, Phillip B.

    1993-01-01

    Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

  7. Parallel scanning probe arrays: their applications

    Directory of Open Access Journals (Sweden)

    Chang Liu

    2008-01-01

    Full Text Available Since the invention of the scanning tunneling microscope (STM1 and the atomic force microscope (AFM2, the field of scanning probe microscopy (SPM instruments has grown steadily and has had a profound influence in materials research, chemistry, biology, nanotechnology, and electronics3,4. Today, scanning probe instruments are used for metrology, characterization5, detection6, manipulation7, patterning8,9, and material modification. A wide range of scanning probe applications are available, taking advantage of various modes of tip–substrate interactions, including force, optics10,11, electrochemistry12, electromagnetics, electrostatics, thermal and mass transfer13,14, and vibration15,16.

  8. Influence of scanning strategies on the accuracy of digital intraoral scanning systems.

    Science.gov (United States)

    Ender, A; Mehl, A

    2013-01-01

    The digital intraoral impression is a central part in today's CAD/CAM dentistry. With its possibilities, new treatment options for the patient is provided and the prosthetic workflow is accelerated. Nowadays, the major issue with intraoral scanning systems is to gain more accuracy especially for larger scan areas and to simplify clinical handling for the dentist. The aim of this study was to investigate different scanning strategies regardingtheir accuracy with full arch scans in an in-vitro study design. A reference master model was used for the digital impressions with the Lava COS, the Cerec Bluecam and a powderfree intraoral scanning system, Cadent iTero. The trueness and precision of each scanning protocol was measured. Lava COS provides the a trueness of 45.8 microm with the scanning protocol recommended from the manufacturer. A different scanning protocol shows significantly lower accuracy (trueness +/- 90.2 microm). Cerec Bluecam also benefits from an optimal scanning protocol with a trueness of +/- 23.3 microm compared to +/- 52.5 microm with a standard protocol. The powderfree impression system Cadent iTero shows also a high accurate full-arch scan with a trueness of +/- 35.0 microm and a precision of +/- 30.9 microm. With the current intraoral scanning systems, full arch dental impressions are possible with a high accuracy, if adequate scan strategies are used. The powderfree scanning system provides the same level of accuracy compared to scanning systems with surface pretreatment. PMID:23641661

  9. ION GUN

    Science.gov (United States)

    Dandl, R.A.

    1961-10-24

    An ion gun is described for the production of an electrically neutral ionized plasma. The ion gun comprises an anode and a cathode mounted in concentric relationship with a narrow annulus between. The facing surfaces of the rear portions of the anode and cathode are recessed to form an annular manifold. Positioned within this manifold is an annular intermediate electrode aligned with the an nulus between the anode and cathode. Gas is fed to the manifold and an arc discharge is established between the anode and cathode. The gas is then withdrawn from the manifold through the annulus between the anode and cathode by a pressure differential. The gas is then ionized by the arc discharge across the annulus. The ionized gas is withdrawn from the annulus by the combined effects of the pressure differential and a collimating magnetic field. In a 3000 gauss magnetic field, an arc voltage of 1800 volts, and an arc current of 0.2 amp, a plasma of about 3 x 10/sup 11/ particles/cc is obtained. (AEC)

  10. Scanning Synchronization of Colliding Bunches for MEIC Project

    Energy Technology Data Exchange (ETDEWEB)

    Derbenev, Yaroslav S. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, V. P. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Chernousov, Yu D. [Inst. of Chemical Kinetics and Combustion, Novosibirsk (Russian Federation); Kazakevich, G. M. [Euclid Techlabs LLC., Cleveland, OH (United States)

    2015-09-01

    Synchronization of colliding beams is one of the major issues of an electron-ion collider (EIC) design because of sensitivity of ion revolution frequency to beam energy. A conventional solution for this trouble is insertion of bent chicanes in the arcs space. In our report we consider a method to provide space coincidence of encountering bunches in the crab-crossing orbits Interaction Region (IR) while repetition rates of two beams do not coincide. The method utilizes pair of fast kickers realizing a bypass for the electron bunches as the way to equalize positions of the colliding bunches at the Interaction Point (IP). A dipole-mode warm or SRF cavities fed by the magnetron transmitters are used as fast kickers, allowing a broad-band phase and amplitude control. The proposed scanning synchronization method implies stabilization of luminosity at a maximum via a feedback loop. This synchronization method is evaluated as perspective for the Medium Energy Electron-Ion collider (MEIC) project of JLab with its very high bunch repetition rate.

  11. Automation of scanning technique by gamma radiation

    International Nuclear Information System (INIS)

    The gamma scan technique is a nuclear test allowing the analysis of the internal mechanical properties of distillation columns used in petrochemical industries. Such technique is performed manually. So we propose in this work to automate the gamma scan procedure test by using a PLC. In addition, supervision and data acquisition interfaces are proposed.

  12. Adrenal scanning with 131I-19-cholesterol

    International Nuclear Information System (INIS)

    The purpose of this paper is to describe our clinical experience of adrenal scanning with 131I-19-cholesterol and discuss its clinical usefulness. Adrenal scanning was performed for 21 patients with hypertension. One millicurie of 131I-19-cholesterol was injected intravenously and adrenal scannings were taken 6 to 11 days after injection with a rectilinear scanner or a gamma camera. No patient had an untoward reaction to the radiopharmaceutical. Confirmed diagnosis was obtained in 7 of 21 patients, i.e., 3 cases of primary aldosteronism, 1 idiopathic aldosteronism, 1 Cushing's syndrome and 2 cases of the essential hypertension. Among all of the primary aldosteronism and Cushing's syndrome, adrenal scanning gave clear evidence of concentration of radioactivity at the site of tumor. In the idiopathic aldosteronism of our study, uptake of radioactivity was brightly visible on the right, while uptake by the left gland was inhibited, so this case was diagnosed incorrectly as primary aldosteronism. The kidney scan with 203Hg-chlormerodrin obtained without moving the patient after an adrenal scan was very useful for getting information of anatomical site of the activity. The effective half-life was calculated as 1.83 days by means of sequential profile whole-body scannings, and the total-body absorbed radiation dose was estimated as 0.65 rad/mCi by using MIRD pamphlets. Our conclusion is that the adrenal scanning with 131I-19-cholesterol is very useful for localization of the functional adrenal cortical tumor. (author)

  13. Camera Systems Rapidly Scan Large Structures

    Science.gov (United States)

    2013-01-01

    Needing a method to quickly scan large structures like an aircraft wing, Langley Research Center developed the line scanning thermography (LST) system. LST works in tandem with a moving infrared camera to capture how a material responds to changes in temperature. Princeton Junction, New Jersey-based MISTRAS Group Inc. now licenses the technology and uses it in power stations and industrial plants.

  14. Live ultrasound volume reconstruction using scout scanning

    Science.gov (United States)

    Meyer, Amelie; Lasso, Andras; Ungi, Tamas; Fichtinger, Gabor

    2015-03-01

    Ultrasound-guided interventions often necessitate scanning of deep-seated anatomical structures that may be hard to visualize. Visualization can be improved using reconstructed 3D ultrasound volumes. High-resolution 3D reconstruction of a large area during clinical interventions is challenging if the region of interest is unknown. We propose a two-stage scanning method allowing the user to perform quick low-resolution scouting followed by high-resolution live volume reconstruction. Scout scanning is accomplished by stacking 2D tracked ultrasound images into a low-resolution volume. Then, within a region of interest defined in the scout scan, live volume reconstruction can be performed by continuous scanning until sufficient image density is achieved. We implemented the workflow as a module of the open-source 3D Slicer application, within the SlicerIGT extension and building on the PLUS toolkit. Scout scanning is performed in a few seconds using 3 mm spacing to allow region of interest definition. Live reconstruction parameters are set to provide good image quality (0.5 mm spacing, hole filling enabled) and feedback is given during live scanning by regularly updated display of the reconstructed volume. Use of scout scanning may allow the physician to identify anatomical structures. Subsequent live volume reconstruction in a region of interest may assist in procedures such as targeting needle interventions or estimating brain shift during surgery.

  15. The white blood cell scan in orthopedics

    Energy Technology Data Exchange (ETDEWEB)

    Propst-Proctor, S.L.; Dillingham, M.F.; McDougall, I.R.; Goodwin, D.

    1982-08-01

    A new nuclear scanning technique was found more specific for bone, joint, and soft tissue infections than any previously described scanning technique. The leukocyte scan, whereby a patient's own cells are labeled with a radioactive tagging agent (/sup 111/In oxine), can distinguish an active infectious process from other pain-inducing conditions. Ninety-seven /sup 111/In labeled autologous leukocyte scans were performed in 88 patients. The findings in 17 of 40 patients scanned for possible acute osteomyelitis, six of nine for suspected septic arthritis, and six for possible soft tissue infections, were positive. Subsequent clinical courses verified the infectious nature of these processes in all patients. Patients who had chronic osteomyelitis (14), bony metastases (four patients), heterotopic ossification (three), and degenerative arthritis (two) demonstrated negative findings. Of the seven patients scanned for acute long-bone fractures, one demonstrated positive findings. Nine scans demonstrated positive findings without determined causes. The leukocyte scan is a useful addition to the diagnostic tools of the orthopedic surgeon.

  16. The white blood cell scan in orthopedics

    International Nuclear Information System (INIS)

    A new nuclear scanning technique was found more specific for bone, joint, and soft tissue infections than any previously described scanning technique. The leukocyte scan, whereby a patient's own cells are labeled with a radioactive tagging agent (111In oxine), can distinguish an active infectious process from other pain-inducing conditions. Ninety-seven 111In labeled autologous leukocyte scans were performed in 88 patients. The findings in 17 of 40 patients scanned for possible acute osteomyelitis, six of nine for suspected septic arthritis, and six for possible soft tissue infections, were positive. Subsequent clinical courses verified the infectious nature of these processes in all patients. Patients who had chronic osteomyelitis (14), bony metastases (four patients), heterotopic ossification (three), and degenerative arthritis (two) demonstrated negative findings. Of the seven patients scanned for acute long-bone fractures, one demonstrated positive findings. Nine scans demonstrated positive findings without determined causes. The leukocyte scan is a useful addition to the diagnostic tools of the orthopedic surgeon

  17. Scanning electron microscopy - application and techniques

    International Nuclear Information System (INIS)

    The application of the scanning electron microscope, and other image forming scanning systems (STEM and the nuclear microprobe), to a range of nuclear reactor problems is described. Particular attention is given to the solution of fracture problems. Autoradiography, electron spectroscopy, and an investigation of irradiation damage in boron carbide using the transmission electron microscope are also described. (author)

  18. MR-scanning ved akut apopleksi

    DEFF Research Database (Denmark)

    Simonsen, Claus Ziegler; Røhl, L; Østergaard, L; Vestergaard-Poulsen, P; Andersen, Grethe; Gyldensted, C

    2001-01-01

    MR is increasingly used as a diagnostic tool in stroke management, especially since new and acute treatments are now available. This article describes the new MR sequences used in the scanning of stroke patients. A scanning protocol is suggested and our preliminary experiences with acute MR...

  19. Scanning tunneling microscopy of dye thin films

    International Nuclear Information System (INIS)

    The Rhodamine 6G films on a metal and a semiconductor substrates were studied by scanning tunneling microscopy and spectral ellipsometry techniques. Scanning tunneling microscopy of dye on a metal substrate allowed obtaining interlayer surface profile with atomic spatial resolution 0.08 nm

  20. A Student-Built Scanning Tunneling Microscope

    Science.gov (United States)

    Ekkens, Tom

    2015-01-01

    Many introductory and nanotechnology textbooks discuss the operation of various microscopes including atomic force (AFM), scanning tunneling (STM), and scanning electron microscopes (SEM). In a nanotechnology laboratory class, students frequently utilize microscopes to obtain data without a thought about the detailed operation of the tool itself.…

  1. Optimal stimulation settings for CMAP scan registrations

    NARCIS (Netherlands)

    E.M. Maathuis (Ellen); R.D. Henderson (Robert); J. Drenthen (Judith); N.M. Hutchinson (Nicole); J.R. Daube (Jasper); J.H. Blok (Joleen); G.H. Visser (Gerhard Henk)

    2012-01-01

    textabstractBackground: The CMAP (Compound Muscle Action Potential) scan is a non-invasive electrodiagnostic tool, which provides a quick and visual assessment of motor unit potentials as electrophysiological components that together constitute the CMAP. The CMAP scan records the electrical activity

  2. Towards high-speed scanning tunneling microscopy

    NARCIS (Netherlands)

    Tabak, Femke Chantal

    2013-01-01

    In this thesis, two routes towards high-speed scanning tunneling microscopy (STM) are described. The first possibility for high-speed scanning that is discussed is the use of MEMS (Micro-Electro Mechanical Systems) devices as high-speed add-ons in STM microscopes. The functionality of these devices

  3. A model for enterprises’ environmental scanning

    OpenAIRE

    Tudor NISTORESCU; Catalin Mihail BARBU

    2006-01-01

    Today’s environment determines companies to use scanning activities in order to seize the opportunities and to avoid the threats. Individual factors and organizational factors influence the scanning behavior. The examination of the environment can be presented in a model based on environment analyzability and organizational intrusiveness.

  4. Environmental Scanning Practices for Rural Colleges.

    Science.gov (United States)

    Friedel, Janice Nahra; Lapin, Joel D.

    1995-01-01

    Discusses the importance of environmental scanning in the planning efforts of rural community colleges. Reviews basic techniques and terminology and suggests sources of data. Argues that environmental scanning allows rural colleges to inexpensively forecast change, identify implications for the organization, and plan preferred responses to shape…

  5. Spatial scan statistics using elliptic windows

    DEFF Research Database (Denmark)

    Christiansen, Lasse Engbo; Andersen, Jens Strodl; Wegener, Henrik Caspar;

    2006-01-01

    The spatial scan statistic is widely used to search for clusters. This article shows that the usually applied elimination of secondary clusters as implemented in SatScan is sensitive to smooth changes in the shape of the clusters. We present an algorithm for generation of a set of confocal elliptic...

  6. Environmental Scanning Is Vital to Strategic Planning.

    Science.gov (United States)

    Poole, Molly Linda

    1991-01-01

    Educators involved in strategic planning can use environmental scanning techniques to anticipate social, economic, political, and technological changes that will affect their schools. Compared to more traditional data gathering, environmental scanning is wider in scope and more concerned with anticipating the future and studying the interaction of…

  7. Computed tomography scanning during a traumatic resuscitation

    NARCIS (Netherlands)

    L.F.M. Beenen; R. Adams; R.W. Koster; T. Otto

    2011-01-01

    In cardiopulmonary resuscitation, computed tomography (CT) imaging could be of decisive importance to therapeutic strategy making but is yet unavailable because of incompatibility of CT scanning and manual chest compressions. In this report, we describe a case in which CT scanning was performed on a

  8. Security scanning of Web sites at CERN

    CERN Multimedia

    IT Department

    2010-01-01

    As of early 2010, the CERN Computer Security Team will start regular scanning of all Web sites and Web applications at CERN, visible on the Internet, or on the General Purpose Network (office network). The goal of this scanning is to improve the quality of CERN Web sites. All deficits found will be reported by e-mail to the relevant Web site owners, and must be fixed in a timely manner. Web site owners may also request one-off scans of their Web site or Web application, by sending an e-mail to Computer.Security@cern.ch. These Web scans are designed to limit the impact on the scanned Web sites. Nevertheless, in very rare cases scans may cause undesired side-effects, e.g. generate a large number of log entries, or cause particularly badly designed or less robust Web applications to crash. If a Web site is affected by these security scans, it will also be susceptible to any more aggressive scan that can be performed any time by a malicious attacker. Such Web applications should be fixed, and also additionally...

  9. Theory of second optimization for scan experiment

    CERN Document Server

    Mo, X H

    2015-01-01

    The optimal design of scan experiment is of great significance both for scientific research and from economical viewpoint. Two approaches, one has recourse to the sampling technique and the other resorts to the analytical proof, are adopted to figure out the optimized scan scheme for the relevant parameters. The final results indicate that for $n$ parameters scan experiment, $n$ energy points are necessary and sufficient for optimal determination of these $n$ parameters; each optimal position can be acquired by single parameter scan (sampling method), or by analysis of auxiliary function (analytic method); the luminosity allocation among the points can be determined analytically with respect to the relative importance between parameters. By virtue of the second optimization theory established in this paper, it is feasible to accommodate the perfectly optimal scheme for any scan experiment.

  10. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  11. Scanning tunneling microscope assembly, reactor, and system

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Feng; Salmeron, Miquel; Somorjai, Gabor A

    2014-11-18

    An embodiment of a scanning tunneling microscope (STM) reactor includes a pressure vessel, an STM assembly, and three spring coupling objects. The pressure vessel includes a sealable port, an interior, and an exterior. An embodiment of an STM system includes a vacuum chamber, an STM reactor, and three springs. The three springs couple the STM reactor to the vacuum chamber and are operable to suspend the scanning tunneling microscope reactor within the interior of the vacuum chamber during operation of the STM reactor. An embodiment of an STM assembly includes a coarse displacement arrangement, a piezoelectric fine displacement scanning tube coupled to the coarse displacement arrangement, and a receiver. The piezoelectric fine displacement scanning tube is coupled to the coarse displacement arrangement. The receiver is coupled to the piezoelectric scanning tube and is operable to receive a tip holder, and the tip holder is operable to receive a tip.

  12. System for programmable micromachining by means of submicron ion beam

    International Nuclear Information System (INIS)

    A system with submicron ion beam is described. Very bright ion beams are generated by electrohydrodynamic source and are focused in electrostatic ion-optical column. An octupole deflector is used for astigmatism correction and beam deviation. Stabilized power supply of all elements is ensured. Lines of 0.1 μm minimum width are obtained. The micromachining process is controlled by an automated system in CAMAC standard on line with Odrenok computer. Specific features of programmable micromachining and operation of the system in the mode of scanning ion microscope are considered

  13. Effects of scanning sensitivity and multiple scan algorithms on microarray data quality

    Directory of Open Access Journals (Sweden)

    Thomson Errol M

    2010-03-01

    Full Text Available Abstract Background Maximizing the utility of DNA microarray data requires optimization of data acquisition through selection of an appropriate scanner setting. To increase the amount of useable data, several approaches have been proposed that incorporate multiple scans at different sensitivities to reduce the quantification error and to minimize effects of saturation. However, no direct comparison of their efficacy has been made. In the present study we compared individual scans at low, medium and high sensitivity with three methods for combining data from multiple scans (either 2-scan or 3-scan cases using an actual dataset comprising 40 technical replicates of a reference RNA standard. Results Of the individual scans, the low scan exhibited the lowest background signal, the highest signal-to-noise ratio, and equivalent reproducibility to the medium and high scans. Most multiple scan approaches increased the range of probe intensities compared to the individual scans, but did not increase the dynamic range (the proportion of useable data. Approaches displayed striking differences in the background signal and signal-to-noise ratio. However, increased probe intensity range and improved signal-to-noise ratios did not necessarily correlate with improved reproducibility. Importantly, for one multiple scan method that combined 3 scans, reproducibility was significantly improved relative to individual scans and all other multiple scan approaches. The same method using 2 scans yielded significantly lower reproducibility, attributable to a lack-of-fit of the statistical model. Conclusions Our data indicate that implementation of a suitable multiple scan approach can improve reproducibility, but that model validation is critical to ensure accurate estimates of probe intensity.

  14. ScanProsite: a reference implementation of a PROSITE scanning tool.

    Science.gov (United States)

    Gattiker, Alexandre; Gasteiger, Elisabeth; Bairoch, Amos

    2002-01-01

    Many different software tools are available publicly to scan the PROSITE database of protein families. However, none of them, to our knowledge, wholly implements the PROSITE syntax, or satisfies all the rules for scanning a pattern against a sequence. We hereby propose a strict definition of how a PROSITE pattern is to be scanned against a sequence, and provide a reference implementation of a tool to scan PROSITE patterns, rules and profiles against protein sequences. PMID:15130850

  15. Simulation of neutron irradiation damage in Al-A5 alloy by ion implantation

    International Nuclear Information System (INIS)

    Ion implantation was used to simulate neutron irradiation damage in Al-A5 alloys. The damage was investigated by scanning electron microscopy. H+ and He+ ions were implanted up to a dose of 2x104 microcuri. It was found, that H+ ions caused the appearacnce of blisters and holes on the surface. The density of the blisters and holes is a function of implanted dose. The He+ ions caused sputtering of surface via flanking. (author)

  16. Breakdown of the iron passive layer by use of the scanning electrochemical microscope

    Energy Technology Data Exchange (ETDEWEB)

    Still, J.W.; Wipf, D.O. [Mississippi State Univ., MS (United States). Dept. of Chemistry

    1997-08-01

    The scanning electrochemical microscope (SECM) is sued to generate localized corrosion at passivating iron surfaces by using the tip to generate Cl{sup {minus}} ions. Use of the SECM allows the rapid establishment of a locally aggressive chemical environment at a preselected site on the iron surface. The susceptibility for passive layer breakdown and corrosion initiation was examined as a function of the time between the start of the passive layer growth and the formation of Cl{sup {minus}} ions. The breakdown of the passive layer was found to depend strongly on the passivation potential and the site of Cl{sup {minus}} formation on the iron surface. In addition to generating Cl{sup {minus}} ions, the SECM tip was simultaneously used to detect large iron ion concentration fluctuations as corrosion began. Current fluctuations at the tip were observed and ascribed to precursors to the passive layer breakdown.

  17. Natural ion exchangers

    International Nuclear Information System (INIS)

    Present article is devoted to natural ion exchangers. Ion exchange properties of minerals are described. Structural types of porous matrixes of natural ion exchangers are considered. Types of sorption centres in minerals are considered as well.

  18. Ion funnel ion trap and process

    Science.gov (United States)

    Belov, Mikhail E [Richland, WA; Ibrahim, Yehia M [Richland, WA; Clowers, Biran H [West Richland, WA; Prior, David C [Hermiston, OR; Smith, Richard D [Richland, WA

    2011-02-15

    An ion funnel trap is described that includes a inlet portion, a trapping portion, and a outlet portion that couples, in normal operation, with an ion funnel. The ion trap operates efficiently at a pressure of .about.1 Torr and provides for: 1) removal of low mass-to-charge (m/z) ion species, 2) ion accumulation efficiency of up to 80%, 3) charge capacity of .about.10,000,000 elementary charges, 4) ion ejection time of 40 to 200 .mu.s, and 5) optimized variable ion accumulation times. Ion accumulation with low concentration peptide mixtures has shown an increase in analyte signal-to-noise ratios (SNR) of a factor of 30, and a greater than 10-fold improvement in SNR for multiply charged analytes.

  19. Formation of submicron scale periodic ripple pattern on Si surface using medium keV Ar-ion beam

    International Nuclear Information System (INIS)

    This paper deals with the effect of beam scanning on the wavelength of the ripples and present our recent results of Ar+ bombarded Si in the energy range 50-140 keV. Systematic atomic force microscopy (AFM) characterization of the morphology of the ripple pattern in the above studies shows that with beam scanning the ripple wavelength increases with ion energy and decreases with energy for bombardment without ion beam scanning

  20. Simulation of low-energy ion scattering

    Science.gov (United States)

    Langelaar, M. H.; Breeman, M.; Mijiritskii, A. V.; Boerma, D. O.

    A new simulation program `MATCH' has been developed for a detailed analysis of low-energy ion scattering (LEIS) and recoiling data. Instead of performing the full calculation of the three-dimensional trajectories through the sample from the ion source towards the detector, incoming trajectories as well as reversed-time outgoing trajectories are calculated, separately. Finally, these trajectories are matched to obtain the yield. The program has been tested for spectra and azimuthal scans of scattering and recoiling events of various sample species in different scattering geometries.

  1. Bone scan in inflammatory osseous disease

    International Nuclear Information System (INIS)

    The /sup 99m/Tc-phosphate bone scan has become a sensitive, reliable, and safe method for evaluating the patient with suspected inflammatory disease of bone. The scan may become positive as early as the first 24 hr after the symptoms and 10-14 days before roentgenographic changes occur. It can be used to differentiate successfully a variety of diseases from osteomyelitis, and in conjunction with 67Ga-citrate scan has become a mainstay in the work-up of the patient with infectious disease. Applications of the bone scan to infectious diseases in pediatric practice are especially helpful, since these diseases are common problems in this age group. Increased experience with the /sup 99m/Tc-phosphate bone scan has already defined several areas of ''limitations'' in evaluating inflammatory disease. ''Cold'' defects, negative scans in early stages of osteomyelitis, and ''extended uptake'' may all pose problems in interpretation, but careful correlation of the bone scan results with clinical history and physical findings, blood cultures, and roentgenography will significantly reduce these problems

  2. Detection of Arthritis by Joint Scanning

    International Nuclear Information System (INIS)

    Detection and identification of early arthritis is frequently difficult with routine methods. Several tracers, 131I human serum albumin (25 μCi/10 lb), 99mTc human serum albumin (1-3 mCi), 131I iodipamide (40 μCi/10 lb), and 99mTc pertechnetate (10 mCi), have been employed for joint scanning to detect synovitis produced by arthritis in joints of the extremities. When administered intravenously, the 25% increase in localization of these tracers in the synovial membrane, if there is active synovitis, can be demonstrated by scintillation scanning. This ability to detect synovitis at an early stage enables the joint scan to show areas of active synovitis not demonstrated on roentgenograms. The scan may objectively confirm or disprove questionable physical findings. From this standpoint the technique has been useful in determining whether joint pain is functional or due to arthritis as a negative localization tends to rule out active synovitis as the cause of the pain. The scan demonstration of a positive localization of the tracer in several joints when only one area is symptomatic is evidence that joint pain is due to systemic disease. The short half-life tracera permit serial studies to follow the course of an arthritis process. Use of 99mTc pertechnetate and an Anger camera have made joint scanning a practical technique for clinical use. A review of the accuracy of joint scanning in 130 cases as compared to roentgenograms is presented. (author)

  3. Tumor scanning with 57Co-bleomycin

    International Nuclear Information System (INIS)

    The clinical application of 57Co-bleomycin as a tumor scanning radiopharmaceutical was firstly reported by Nouel and Maeda respectively. The authors conducted studies on the diagnostic significance of this tumor scanning agent and presented the results obtained in 40 patients with malignant and non malignant lesions. Six hours and 24 hours after the injection of 500 μCi of 57Co-bleomycin, scintigrams were taken with a 3-inch scintiscanner. Positive scans were found in 20 out of 36 patients with various malignant tumors. Of 20 patients with lung cancer, positive scans were obtained in 17 cases (85%) and of 6 with breast cancer, 3 cases showed positive scans. False negative scans were obtained in another 10 cases of malignant tumors (3 cases of thyroid carcinoma, 4 cases of hepatoma, and 1 case each of gastric carcinoma, peritoneal carcinomatosis, and reticulum cell sarcoma). Of 4 patients with non malignant disease, one case of pulmonary tuberculosis showed a positive scan. In 8 cases of lung cancer and 6 of breast cancer, the relationship between the size of the excised tumor and the scintigram findings was studied. The smallest tumors detected by scintigram were 2 cm in lung cancer and 3.2 cm in breast cancer. (author)

  4. Spectrally encoded confocal scanning laser ophthalmoscope

    Science.gov (United States)

    Tao, Yuankai K.; Izatt, Joseph A.

    2010-02-01

    Fundus imaging has become an essential clinical diagnostic tool in ophthalmology. Current generation scanning laser ophthalmoscopes (SLO) offer advantages over conventional fundus photography and indirect ophthalmoscopy in terms of light efficiency and contrast. As a result of the ability of SLO to provide rapid, continuous imaging of retinal structures and its versatility in accommodating a variety of illumination wavelengths, allowing for imaging of both endogenous and exogenous fluorescent contrast agents, SLO has become a powerful tool for the characterization of retinal pathologies. However, common implementations of SLO, such as the confocal scanning laser ophthalmoscope (CSLO) and line-scanning laser ophthalmoscope (LSLO), require imaging or multidimensional scanning elements which are typically implemented in bulk optics placed close to the subject eye. Here, we apply a spectral encoding technique in one dimension combined with single-axis lateral scanning to create a spectrally encoded confocal scanning laser ophthalmoscope (SECSLO) which is fully confocal. This novel implementation of the SLO allows for high contrast, high resolution in vivo human retinal imaging with image transmission through a single-mode optical fiber. Furthermore, the scanning optics are similar and the detection engine is identical to that of current-generation spectral domain optical coherence tomography (SDOCT) systems, potentially allowing for a simplistic implementation of a joint SECSLO-SDOCT imaging system.

  5. Prospects of the scanning low energy electron microscopy in materials science

    Czech Academy of Sciences Publication Activity Database

    Mikmeková, Šárka; Hovorka, Miloš; Konvalina, Ivo; Müllerová, Ilona; Frank, Luděk

    Brno : Institute of Scientific Instruments AS CR, v.v.i, 2010 - (Mika, F.), s. 37-38 ISBN 978-80-254-6842-5. [International Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation /12./. Skalský dvůr (CZ), 31.05.2010-04.06.2010] R&D Projects: GA MŠk OE08012 Institutional research plan: CEZ:AV0Z20650511 Keywords : scanning low energy electron microscopy * scanning electron microscopy * transmission electron microscopy * focused ion beam microscopy * cathode lens mode Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  6. Pinpoint attack on cancer cell with ions

    International Nuclear Information System (INIS)

    Microbeam technology is indispensable in bio-scientific research, for example the investigation of cell-to-cell communications such as bystander effects, the analysis of cellular spatial sensitivity, the interaction of damage caused by individual irradiation, cellular repair dynamics, and intra-cellular processes such as apoptosis. A single-ion hit technique using the heavy-ion microbeam is being developed at JAEA AVF cyclotron facility for elucidate of biofunctions. A heavy ion microbeam system was developed using a beam collimator with a 5 μm diameter hole. In the new system the microbeam spot was focused to 0.7 μm in diameter using focusing lenses. The PIXE analysis has been widely applied in the fields of biology and medicine. The use of micro-beams allows analyzing trace elements on the cellular level as well. In Air Micro-PIXE images the elemental distribution in the cell by scanning the micro-beams. Biological effects of heavy ion particle beams are markedly more potent, and the dose distribution of heavy ion particle beams is more concentrated than those of X-ray and gamma ray. Therefore, radiotherapy using heavy ion particle beams not only improves the prognosis of cancer patients, but significantly contributes to improvement of their quality of life by conserving the function and morphology of affected organs. A highly precise carbon ion microsurgery system will be developed to treat various small tumours based on the technique of microbeam formation. (author)

  7. Theory for broadband detection of ion cyclotron resonance signals

    Science.gov (United States)

    McIver, Robert T.; Ledford, Edward B.; Hunter, Richard L.

    1980-02-01

    A complete line shape theory is developed for the transient response of a new type of ion cyclotron resonance (ICR) detector circuit. The detector is basically a balanced capacitance bridge which is sensitive to the abundance of gaseous ions stored in a static magnetic ion trap. For the first time, the equations of motion of ions in the ICR analyzer cell are shown to be coupled to the circuit equations of the detector. Also, the effect of nonreactive ion-molecule collisions on line shapes and on the transient response of the detector are analyzed and shown to allow measurement of ion-molecule collisions frequencies as a function of ion translational energy. One of the most important features of the capacitance bridge detector is its broadband sensitivity to a wide range of ion cyclotron resonance frequencies. This allows a mass spectrum of ions stored in the ICR analyzer cell to be obtained by scanning the frequency ω1 of the irradiating rf electric field at a fixed magnetic field strength. The capacitance bridge circuit can serve not only as a direct replacement for marginal oscillator circuits traditionally used in ICR experiments, but also as the detector for recently developed Fourier Transform and Rapid Scan ICR experiments.

  8. Feedback Effects in Combined Fast-Scan Cyclic Voltammetry-Scanning Electrochemical Microscopy

    OpenAIRE

    Schrock, Daniel S.; Wipf, David O.; Baur, John E.

    2007-01-01

    Fast-scan cyclic voltammetry at scan rates between 5 and 1000 Vs−1 was performed at the tip of a scanning electrochemical microscope immersed in a solution of redox mediator. The effect of conducting and insulating substrates on the voltammetric signal was investigated as a function of scan rate and tip-substrate distance. It was found that diffusional interactions between the tip and the substrate are greatest at lower scan rates and on the reverse sweep of the voltammogram. At the fastest s...

  9. Bone scan in diagnosis of infectious osteoarthritis

    International Nuclear Information System (INIS)

    Bone scan with Technetium 99m is harmless method of evaluation of skeletal lesions. It is safe in pediatrics age group and it can be used in early diagnosis of infectious osteoarthritis. Bone scan differentiate osteomyelitis from cellulitis, and also it may help in diagnosis of subclinical involvement of rheumatoid arthritis, benign and malignant bone tumors, stress fractures and periostitis. We report results of bone scan in 30 pediatrics patients as follow: osteomyelitis 9 cases, cellulitis 4 cases, infectious arthritis 7 cases, tuberculous osteoarthritis 2 cases, rheumatoid arthritis 2 cases, and other different diseases 9 cases

  10. Bone scan in diagnosis of infectious osteoarthritis

    International Nuclear Information System (INIS)

    Bone scan with Technetium 99m is harmless method of evaluation of skeletal lesions. It is safe in pediatrics age group and it can be used in early diagnosis of infectious osteo-arthritis. Bone scan differentiate osteomyelitis from cellulitis, and also it may help in diagnosis of subclinical involvement of rheumatoid arthritis, benign and malignant bone tumors, stress fractures and periostitis. We report results of bone scan in 30 pediatric patients as follows: osteomyelitis 9 cases, cellulitis 4 cases, infectious arthritis 4 cases, tuberculous osteoarthritis 2 cases, rheumatoid arthritis 2 cases and other different diseases 9 cases

  11. Reconstruction the KROKUS scanning measuring projector

    International Nuclear Information System (INIS)

    Modernized scanning measuring projector, designated for primary scanning of films from bubble chambers is described. Detailed consideration is given to electronic circuit for controlling film-pulling mechanism in three modes: slow pulling, fast pulling and start-stop conditions. Controle unit for scanning device contains the following basic elements: the circuit of controlling by operating elements, photorelay circuit, phase shifting unit and supply unit of projector lamps and electric drive. The maximal image dimension on the screen - 400X600 mm. Film-pulling mechanism enables to load both 35 and 50 mm films

  12. Feature Adaptive Sampling for Scanning Electron Microscopy

    OpenAIRE

    Dahmen, Tim; Engstler, Michael; Pauly, Christoph; Trampert, Patrick; de Jonge, Niels; Mücklich, Frank; Slusallek, Philipp

    2016-01-01

    A new method for the image acquisition in scanning electron microscopy (SEM) was introduced. The method used adaptively increased pixel-dwell times to improve the signal-to-noise ratio (SNR) in areas of high detail. In areas of low detail, the electron dose was reduced on a per pixel basis, and a-posteriori image processing techniques were applied to remove the resulting noise. The technique was realized by scanning the sample twice. The first, quick scan used small pixel-dwell times to gener...

  13. CT scan for suspected acute appendicitis

    OpenAIRE

    Widlus, David M.

    2012-01-01

    Appendicitis is common with a 7% lifetime risk for an individual in the United States. Mean age at diagnosis is 22 years old. While frequently clinically obvious, by 2006, more than 90% of patients diagnosed with appendicitis had a CT scan of the abdomen and pelvis performed. Use of CT scans has allowed a decrease in false-negative rate at appendectomy to under 10% from a rate of approximately 20% before routine use of CT scan. In addition, the rate of perforation has decreased from nearly 30...

  14. Diagnostic value of the coronary CT scan

    International Nuclear Information System (INIS)

    Using high-resolution computed tomography, coronary scanning has been made to investigate the radiographical details of the middle and inner ear organs. Twenty patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, facial spasm, and suspected meningitis, were evaluated. In 26 of 40 ears in this series, the coronary scans sharply outlined almost all of the bony structures, and showed also the eardrum as a clearly defined soft tissue, but no abnormal radiographical findings were recognized. In the remaining ears with chronic otitis media, the scans were valuable in demonstration of mucosal thickening, granulation tissue, and destruction of the auditory ossicles. (author)

  15. Diagnostic value of the coronary CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Kiuchi, S. (Tsukuba Univ., Sakura (Japan))

    1982-09-01

    Using high-resolution computed tomography, coronary scanning has been made to investigate the radiographical details of the middle and inner ear organs. Twenty patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, facial spasm, and suspected meningitis, were evaluated. In 26 of 40 ears in this series, the coronary scans sharply outlined almost all of the bony structures, and showed also the eardrum as a clearly defined soft tissue, but no abnormal radiographical findings were recognized. In the remaining ears with chronic otitis media, the scans were valuable in demonstration of mucosal thickening, granulation tissue, and destruction of the auditory ossicles.

  16. Clinical applications of Genome Polymorphism Scans

    Directory of Open Access Journals (Sweden)

    Weber James L

    2006-06-01

    Full Text Available Abstract Applications of Genome Polymorphism Scans range from the relatively simple such as gender determination and confirmation of biological relationships, to the relatively complex such as determination of autozygosity and propagation of genetic information throughout pedigrees. Unlike nearly all other clinical DNA tests, the Scan is a universal test – it covers all people and all genes. In balance, I argue that the Genome Polymorphism Scan is the most powerful, affordable clinical DNA test available today. Reviewers: This article was reviewed by Scott Weiss (nominated by Neil Smalheiser, Roberta Pagon (nominated by Jerzy Jurka and Val Sheffield (nominated by Neil Smalheiser.

  17. Scanning spreading resistance microscopy of shallow doping profiles in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Suchodolskis, A. [Royal Inst. of Technology, IMIT-MSP, P.O. Box Electrum 229 SE-164 40 Kista (Sweden) and Semiconductor Physics Institute, LT 01108 Vilnius (Lithuania)]. E-mail: suchy@pfi.lt; Hallen, A. [Royal Inst. of Technology, IMIT-MSP, P.O. Box Electrum 229 SE-164 40 Kista (Sweden); Gran, J. [Justervesendet, Fetveien 99, N-2007 Kjeller (Norway); Hansen, T.-E. [AME, P.O. Box 83, N-3191 Horten (Norway); Karlsson, U.O. [Royal Inst. of Technology, IMIT-MSP, P.O. Box Electrum 229 SE-164 40 Kista (Sweden)

    2006-12-15

    We demonstrate the application of scanning spreading resistance microscopy (SSRM) for characterization of shallow highly-conductive layers formed by boron implantation of lowly doped n-type silicon substrate followed by a post-implantation annealing. The electrically active dopant concentration versus depth was obtained from a cross-section of freshly cleaved samples where the Si-surface could be clearly distinguished by depositing a SiO{sub 2}-layer before cleavage. To quantify free carrier concentration we calibrated our data against samples with implanted/annealed boron profiles established by secondary ion mass spectrometry (SIMS). A good fit of SSRM and SIMS data is possible for free carrier concentrations lower than 10{sup 20} cm{sup -3}, but for higher concentrations there is a discrepancy indicating an incomplete activation of the boron.

  18. The Emulsion Scanning System of the OPERA experiment

    CERN Document Server

    Juget, F

    2010-01-01

    The OPERA experiment has for goal the direct detection of !μ ! !! oscilla- tion, using an hybrid apparatus composed of electronic detectors and nuclear photographic emulsions. A charged particle crossing an emulsion layer ion- izes the medium along its path leaving a latent image which leads, after de- velopment, to a sequence of aligned grains. Nuclear emulsions are analyzed by means of optical microscopes to reconstruct the 3D particle tracks. The OPERA collaboration has developed a dedicated system to scan a large num- ber of emulsions (surface of about 1000 m2). The achieved resolution is "1 μm and "1 mrad allowing to observe directly the short-lived " particles pro- duced in !!CC interactions.

  19. LHC Report: Ion Age

    CERN Multimedia

    John Jowett for the LHC team

    2013-01-01

    The LHC starts the New Year facing a new challenge: proton-lead collisions in the last month before the shutdown in mid-February.    Commissioning this new and almost unprecedented mode of collider operation is a major challenge both for the LHC and its injector chain. Moreover, it has to be done very quickly to achieve a whole series of physics goals, requiring modifications of the LHC configuration, in a very short time. These include a switch of the beam directions halfway through the run, polarity reversals of the ALICE spectrometer magnet and Van der Meer scans.    The Linac3 team kept the lead source running throughout the end-of-year technical stop, and recovery of the accelerator complex was very quick. New proton and lead beams were soon ready, with a bunch filling pattern that ensures they will eventually match up in the LHC. The LEIR machine has even attained a new ion beam intensity record.  On Friday 11 January the first single bunches o...

  20. Bone scan and joint scan of hands and feet in rheumatoid arthritis

    International Nuclear Information System (INIS)

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate 99mTc intravenous injection. Patients were scanned 5 minutes (tissual time, Tt) and 3 hours 1/4 (bone time, T0) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of 99mTc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T0. The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)