WorldWideScience

Sample records for axonopodis pv phaseoli

  1. Characterization of Xanthomonas axonopodis pv. phaseoli isolates

    NARCIS (Netherlands)

    Nunes, W.M.C.; Corazza, M.J.; De Souza, S.A.C.D.; Tsai, S.M.; Kuramae, E.E.

    2008-01-01

    A simple, quick and easy protocol was standardized for extraction of total DNA of the bacteria Xanthomonas axonopodis pv. phaseoli. The DNA obtained by this method had high quality and the quantity was enough for the Random Amplified Polymorphic DNA (RAPD) reactions with random primers, and Polymera

  2. Genome sequencing reveals a new lineage associated with lablab bean and genetic exchange between Xanthomonas axonopodis pv. phaseoli and Xanthomonas fuscans subsp. fuscans

    Directory of Open Access Journals (Sweden)

    Valente eAritua

    2015-10-01

    Full Text Available Common bacterial blight is a devastating seed-borne disease of common beans that also occurs on other legume species including lablab and Lima beans. We sequenced and analysed the genomes of 26 isolates of Xanthomonas axonopodis pv. phaseoli and X. fuscans subsp. fuscans, the causative agents of this disease, collected over four decades and six continents. This revealed considerable genetic variation within both taxa, encompassing both single-nucleotide variants and differences in gene content, that could be exploited for tracking pathogen spread. The bacterial isolate from Lima bean fell within the previously described Genetic Lineage 1, along with the pathovar type isolate (NCPPB 3035. The isolates from lablab represent a new, previously unknown genetic lineage closely related to strains of X. axonopodis pv. glycines. Finally, we identified more than 100 genes that appear to have been recently acquired by Xanthomonas axonopodis pv. phaseoli from X. fuscans subsp. fuscans.

  3. Bioassay for selection of biocontroller bacteria against bean common blight (Xanthomonas axonopodis pv. phaseoli Bioensaio para seleção de bactérias biocontroladoras do crestamento bacteriano comum do feijão (Xanthomonas axonopodis pv. phaseoli

    Directory of Open Access Journals (Sweden)

    Zarela G.C.N. Zanatta

    2007-09-01

    Full Text Available Emphasis has been given on selection of micro-organism for biological control. However, in order to evaluate the biological control potential of a great number of micro-organisms in a small period of time it is necessary to develop an efficient bioassay. Seven hundred and sixty bacterial isolates from different habitats, were selected for compatibility with Rhizobium leguminosarum bv. phaseoli (SEMIA 4077 e SEMIA 4080. Among them 596 isolates were ineffective against both rhizobia. Bean seeds immersed in suspension of each one of these isolates were agitated for 5 hours at 10ºC and sowed in non-sterilized soil. The plants were kept in greenhouse. After the development of cotyledonary and primary leaves, these were removed and bioassayed for Xanthomonas axonopodis pv. phaseoli (XAP control. In the cotyledonary leaves, it was observed that the isolate DFs093 offered 100% control, DFs041 and DFs1297 offered 90% and DFs490, DFs769, DFs831, DFs842 and DFs843 offered 80% control. In the primary leaves, the DFs482 isolated offered 100% and the DFs080, DFs348, DFs513, DFs622, DFs769, DFs842 and DFs912 offered 80% of XAP control.Tem-se dado muita ênfase ao controle biológico mediante seleção de microorganismos. Porém, para se avaliar o potencial de biocontroladores de forma massal e em pequeno intervalo de tempo é necessário desenvolver um bioensaio eficiente. Bactérias de diferentes sítios, num total de 760 isolados, foram selecionadas para compatibilidade com Rhizobium leguminosarum bv. phaseoli estirpes SEMIA 4077 e SEMIA 4080, onde 596 isolados foram inefetivos contra ambos rizóbios. Sementes de feijão foram imersas em suspensão de cada um destes isolados sendo agitadas por 5 horas a 10ºC, plantadas em solo não esterelizado, sendo as plantas mantidas em casa de vegetação. Após o desenvolvimento das folhas cotiledonares e folhas primárias, estas foram retiradas e avaliadas por bioensaio para o controle de Xanthomonas axonopodis pv

  4. Occurrence of Xanthomonas axonopodis pv. phaseoli, the causal agent of common bacterial blight disease, on seeds of common bean (Phaseolus vulgaris L.) in upper Egypt.

    Science.gov (United States)

    Abd-Alla, M H; Bashandy, S R; Schnell, S

    2010-01-01

    Common bean seed lots collected from different seed dealers and Malawii agriculture station were screened for the presence of Xanthomonas axonopodis pv. phaseoli. In the laboratory the pathogen was isolated following the routine laboratory assay method, i.e. direct plating method using yeast extract-dextrose-calcium carbonate agar medium (YDC). Yellow, convex, mucoid colonies of Xanthomonas were consistently isolated on YDC from seed samples. The presumptive pathogen was confirmed by isolation on semiselective medium, such as mTBM and MD5A. Further, the pathogen was confirmed by biochemical, physiological and, finally, the pathogenicity tests. Five samples out of seven were positive for Xanthomonas. The isolates were found to cause common blight of 3-week-old common bean plants by 7 d after inoculation. Bacteria with the same characteristics as those inoculated were re-isolated from the infected plants.

  5. Alterações metabólicas em plantas de feijão originadas de sementes microbiolizadas por Pseudomonas sp. e inoculadas com Xanthomonas axonopodis pv. phaseoli Metabolic alterations on bean plants originated from microbiolization of seeds with Pseudomonas sp. and inoculated with Xanthomnas axonopodis pv. phaseoli

    Directory of Open Access Journals (Sweden)

    Eliane Gonçalves da Silva

    2009-06-01

    Full Text Available Muitas enzimas estão envolvidas em reações de defesa de plantas contra patógenos. O objetivo deste trabalho foi verificar alterações na atividade de algumas destas enzimas em plantas de feijão originadas de sementes microbiolizadas com um isolado de Pseudomonas do grupo das fluorescentes (isolado DFs842. Sementes de feijão cultivar BRS Valente foram imersas em suspensão salina preparada a partir de crescimento bacteriano com 24 h do isolado de Pseudomonas (OD540=0,5 sabidamente biocontroladora de Xanthomonas axonopodis pv. phaseoli. Como testemunhas, as sementes foram imersas em solução salina (NaCl 0,85%. Após a microbiolização por 5 h a 10ºC, as sementes foram plantadas em vasos contendo uma mistura de solo não esterilizado, areia e esterco bovino (proporção 3:1:1, mantidos em casa de vegetação. A inoculação do patógeno foi realizada na terceira folha verdadeira de todas as plantas, fazendo-se cortes com tesoura imersa em suspensão salina do patógeno (X. axonopodis pv. phaseoli preparada a partir de crescimento de 24 h (OD540=0,4. Câmaras úmidas foram mantidas 24 h antes e após a inoculação. Para o preparo do extrato protéico, as três primeiras folhas verdadeiras foram coletadas individualmente em 5 épocas de coleta distintas: uma, momentos antes da inoculação e as demais nos tempos seis, 24, 72 h e 15 dias após a inoculação. Este extrato protéico serviu de fonte para as determinações do teor de proteínas solúveis totais (PST, atividade da polifenol oxidase (PPO e da peroxidase (PO, as quais foram realizadas por leituras espectrofotométricas. Os resultados demonstraram aumento significativo no teor de PST e na atividade de PPO nas plantas submetidas ao tratamento com isolado DFs842, sendo que, o teor de PST foi o dobro, em relação às plantas não tratadas. Também foi observado que, mesmo antes da inoculação do patógeno o teor de PST e a atividade de PPO nas plantas tratadas estavam bem maiores

  6. RESPUESTA A BACTERIOSIS COMÚN (Xanthomonas axonopodis p.v phaseoli EN LOS CULTIVARES COMERCIALES DE FRIJOL COMÚN DE CUBA, EN CONDICIONES DE CAMPO. AFECTACIÓN DE LOS RENDIMIENTOS POR EFECTO DE LA INOCULACIÓN

    Directory of Open Access Journals (Sweden)

    Odile Rodríguez Miranda

    2015-01-01

    Full Text Available En el germoplasma de frijol común (Phaseolus vulgaris L., en Cuba, es posible identificar cultivares con niveles de resistencia ante un aislamiento patogénico de Xanthomonas axonopodis pv. phaseoli, a fin de disminuir las pérdidas y aumentar el rendimiento promedio del cultivo en campos infectados con este patógeno. Los objetivos de este trabajo estuvieron dirigidos a evaluar, en genotipos de frijol común respuestas contrastantes frente a la incidencia natural e inoculación del aislamiento patogénico Xap527 (Xanthomonas axonopodis; identificar los cultivares comerciales con mejor comportamiento en follaje y vainas y con menores pérdidas de rendimiento en campos infectados por este patógeno. Los resultados permitieron seleccionar los genotipos de frijol, con buen comportamiento frente al aislamiento de Xap estudiado y se determinó la disminución del rendimiento en los cultivares de frijol por su reacción de susceptibilidad frente a Bacteriosis común, con la inoculación del aislamiento Xap 527, de Cuba

  7. Otimização da técnica de PCR para a detecção de Xanthomonas axonopodis pv. phaseoli em sementes de feijão Optimization of PCR technique for detection of Xanthomonas axonopodis pv. phaseoli in bean seeds

    Directory of Open Access Journals (Sweden)

    Franklin Cordeiro Silva

    2013-03-01

    Full Text Available O crestamento bacteriano comum, causado por Xanthomonas axonopodis pv. phaseoli (Xap, é a principal bacteriose do feijoeiro no Brasil, sendo transmitida principalmente por sementes. O presente trabalho teve como objetivo aperfeiçoar uma técnica, por meio de diferentes métodos de preparação do extrato, para a detecção de Xap, bem como sua detecção simultânea com Curtobacterium flaccumfaciens pv. flaccumfaciens (Cff nos extratos de sementes de feijão,via PCR. A partir de amostras de sementes de feijão inoculadas artificialmente com Xap e lotes comerciais, foram avaliados: extrato bruto obtido diretamente das sementes, extrato concentrado por filtração em membrana de 0,22µM de diâmetro, extrato concentrado por centrifugação e extrato plaqueado em meio semi-seletivo XCP1 com e sem antibióticos (BIO-PCR. Avaliou-se a presença simultânea de Xap e Cff em 10 lotes comerciais de sementes de feijão através da reação multiplex, utilizandos-se os primers X4c, X4e, CffFOR2 e CffREV4. A partir do extrato bruto, do extrato concentrado por centrifugação e por filtragem em membrana Millipore® não foi possível a detecção de Xap nas sementes de feijão artificialmente contaminadas nem nos 47 lotes comerciais de sementes/ grãos de feijão. A técnica de BIO-PCR permitiu a detecção de Xap a partir de extratos de sementes de feijão artificialmente contaminadas e em 18 dos 47 lotes comerciais. A técnica de detecção simultânea de Xap e Cff no mesmo gel é viável, por amplificar fragmentos de DNA típicos de cada fitobactéria. O uso do meio de cultura XCP1 sem adição de antibióticos permitiu detectar Xap com período de incubação menor em um dia em comparação à detecção utilizando-se o meio de cultura com antibióticosCommon bacterial blight, caused by Xanthomonas axonopodis pv. phaseoli (Xap, is the major bacteriosis affecting bean plants in Brazil and is mainly transmitted by seeds. This study aimed to improve a

  8. Estrategias para diferenciar xanthomonas campestris pv. phaseoli con sales inorgánicas

    Directory of Open Access Journals (Sweden)

    Mildred Zapata

    2001-01-01

    Full Text Available Colonias de Xanthomonas campestris pv. phaseoli (Xcp aisladas de hojas de habichuelas con síntomas de tizón común en Puerto Rico, República Dominicana y Costa Rica fueron caracterizadas como patogénicas en hojas de Phaseolus vulgaris. Sin embargo, éstas fueron clasificadas en los patovares phaseoli, vesicatoria, carotae y xanthosoma por el sistema Biolog. Las cepas de Xcp crecidas en 2, 3, 5-Trifenil cloruro de tetrazolio (TTC mostraron colonias convexas, brillosas, lisas y de color rojo en diferentes tamaños. TTC fue reducido por las cepas de Xcp a un pigmento rojo intenso, un formazán de trifenilo. No se encontraron diferencias en virulencia y tipos de colonias en las cepas identificadas por pruebas de patogenicidad como Xcp. Por otro lado, hubo diferencias en el tipo de colonia en cultivos bacterianos identificados como: Pseudomonas cissicola, P. fulva, Corynebacterium, Rhodococcus, y Shingomonas

  9. Insights into xanthomonas axonopodis pv. Citri biofilm through proteomics

    KAUST Repository

    Zimaro, Tamara

    2013-08-07

    Background: Xanthomonas axonopodis pv. Citri (X. a. pv. Citri) causes citrus canker that can result in defoliation and premature fruit drop with significant production losses worldwide. Biofilm formation is an important process in bacterial pathogens and several lines of evidence suggest that in X. a. pv. Citri this process is a requirement to achieve maximal virulence since it has a major role in host interactions. In this study, proteomics was used to gain further insights into the functions of biofilms. Results: In order to identify differentially expressed proteins, a comparative proteomic study using 2D difference gel electrophoresis was carried out on X. a. pv. Citri mature biofilm and planktonic cells. The biofilm proteome showed major variations in the composition of outer membrane proteins and receptor or transport proteins. Among them, several porins and TonB-dependent receptor were differentially regulated in the biofilm compared to the planktonic cells, indicating that these proteins may serve in maintaining specific membrane-associated functions including signaling and cellular homeostasis. In biofilms, UDP-glucose dehydrogenase with a major role in exopolysaccharide production and the non-fimbrial adhesin YapH involved in adherence were over-expressed, while a polynucleotide phosphorylase that was demonstrated to negatively control biofilm formation in E. coli was down-regulated. In addition, several proteins involved in protein synthesis, folding and stabilization were up-regulated in biofilms. Interestingly, some proteins related to energy production, such as ATP-synthase were down-regulated in biofilms. Moreover, a number of enzymes of the tricarboxylic acid cycle were differentially expressed. In addition, X. a. pv. Citri biofilms also showed down-regulation of several antioxidant enzymes. The respective gene expression patterns of several identified proteins in both X. a. pv. Citri mature biofilm and planktonic cells were evaluated by

  10. Crestamento foliar, nova sintomatologia em algodoeiro causada por Xanthomonas axonopodis pv. malvacearum Cotton leaf blight, a new symptomatology caused by Xanthomonas axonopodis pv. malvacearum

    Directory of Open Access Journals (Sweden)

    Valdemar Atílio Malavolta Jr.

    2008-06-01

    Full Text Available Foi observada recentemente no Estado de São Paulo uma nova sintomatologia em algodoeiro cv. Makina, IAC 24 e Detaopal, causada por Xanthomonas axonopodis pv. malvacearum (Xam, denominada "crestamento foliar". Caracteriza-se por crestamento foliar, geralmente acompanhado por halo clorótico, podendo também causar sintomas de "V" invertido, a partir dos bordos foliares. Linhagens de Xam foram comparadas, por meio de testes de patogenicidade, bioquímicos, sorológicos, culturais e PCR-RFLP da região espaçadora 16S-23S DNAr. Independentemente do tipo de sintoma, as linhagens apresentaram características e perfis idênticos aos apresentados pela linhagem tipo, confirmando a identidade dos isolados como Xanthomonas axonopodis pv. malvacearum.Recently a new symptomatology on cotton plants (cv. Makina, IAC 24 and Deltaopal caused by Xanthomonas axonopodis pv. malvacearum (Xam was observed in São Paulo state, Brazil, and named "bacterial leaf blight". The symptom was characterized by leaf blight, generally exhibiting chlorotic haloes and sometimes showing V-shaped lesions beginning at the leaves' border. Strains of Xam responsible for typical angular leaf spots and bacterial leaf blight were compared through pathological, biochemical, serological, cultural and RFLP-PCR tests of the 16S-23S spacer region. Independently of the symptom type, the strains exhibited characteristics and profiles that were identical to those exhibited by the type strain, which confirms the isolates identity Xanthomonas axonopodis pv. malvacearum

  11. Caracterização de isolados de Xanthomonas axonopodis pv. manihotis = Characterization of isolates of Xanthomonas axonopodis pv. manihotis

    Directory of Open Access Journals (Sweden)

    Roberto Luis Portz

    2006-07-01

    Full Text Available A bacteriose (Xanthomonas axonopodis pv. manihotis e a doenca de maior importancia economica na cultura da mandioca. Para estudar a variabilidade genetica desta bacteria no Oeste do Parana, foram realizados levantamentos em Entre Rios do Oeste, Marechal Candido Rondon, Mercedes, Missal, Nova Santa Rosa e Pato Bragado. Os isolados foram caracterizados em relacao a atividade de amilase, ƒ¿ e ƒÀ-esterase e agressividade. Dos 61 materiais vegetais coletados, obtiveram-se 19 isolados da bacteria, com maior incidencia para variedades de mesa em relacao aqueles para industria. Manivas provenientes de Pato Bragado, Entre Rios do Oeste e Mercedes apresentaram incidencias de 10, 27 e 10%, respectivamente, valores inferiores aos de Marechal Candido Rondon (50% e Nova Santa Rosa (58%. Os isolados foram agrupados em cinco, seis e 12 grupos em relacao a capacidade amilolitica, agressividade e isoenzimas de esterase, respectivamente. Nao houve relacao entre atividade de amilase e agressividade. Isolados de Marechal Candido Rondon foram mais agressivos que os provenientes das outras regioes. O agrupamento com base em esterase permitiu verificar que isolados provenientes de Entre Rios do Oeste, Nova Santa Rosa e Mercedes apresentaram alto grau de similaridade. Estes resultados indicam haver diferenciacaoentre os isolados da bacteria presentes nos municipios amostrados.The bacterial blight (Xanthomonas axonopodis pv. manihotis is the most important disease of cassava. To study the genetic variability of pathogen in the West of Parana, a research was carried out at Entre Rios do Oeste, Marechal Candido Rondon, Mercedes, Missal, Nova Santa Rosa and Pato Bragado. The isolates were characterized to amylase activity, ƒ¿ and ƒÀ-esterase and aggressiveness. From 61 collected materials, were obtained 19 bacterial isolates, with larger incidence for varieties of human consume than those for industry. Stems from Pato Bragado, Entre Rios do Oeste and Mercedes

  12. Comparative genomic analysis of Xanthomonas axonopodis pv. citrumelo F1, which causes citrus bacterial spot disease, and related strains provides insights into virulence and host specificity.

    Science.gov (United States)

    Jalan, Neha; Aritua, Valente; Kumar, Dibyendu; Yu, Fahong; Jones, Jeffrey B; Graham, James H; Setubal, João C; Wang, Nian

    2011-11-01

    Xanthomonas axonopodis pv. citrumelo is a citrus pathogen causing citrus bacterial spot disease that is geographically restricted within the state of Florida. Illumina, 454 sequencing, and optical mapping were used to obtain a complete genome sequence of X. axonopodis pv. citrumelo strain F1, 4.9 Mb in size. The strain lacks plasmids, in contrast to other citrus Xanthomonas pathogens. Phylogenetic analysis revealed that this pathogen is very close to the tomato bacterial spot pathogen X. campestris pv. vesicatoria 85-10, with a completely different host range. We also compared X. axonopodis pv. citrumelo to the genome of citrus canker pathogen X. axonopodis pv. citri 306. Comparative genomic analysis showed differences in several gene clusters, like those for type III effectors, the type IV secretion system, lipopolysaccharide synthesis, and others. In addition to pthA, effectors such as xopE3, xopAI, and hrpW were absent from X. axonopodis pv. citrumelo while present in X. axonopodis pv. citri. These effectors might be responsible for survival and the low virulence of this pathogen on citrus compared to that of X. axonopodis pv. citri. We also identified unique effectors in X. axonopodis pv. citrumelo that may be related to the different host range as compared to that of X. axonopodis pv. citri. X. axonopodis pv. citrumelo also lacks various genes, such as syrE1, syrE2, and RTX toxin family genes, which were present in X. axonopodis pv. citri. These may be associated with the distinct virulences of X. axonopodis pv. citrumelo and X. axonopodis pv. citri. Comparison of the complete genome sequence of X. axonopodis pv. citrumelo to those of X. axonopodis pv. citri and X. campestris pv. vesicatoria provides valuable insights into the mechanism of bacterial virulence and host specificity.

  13. Cloning of a two-component signal transduction system of Xanthomonas campestris pv. phaseoli var. fuscans strain BXPF65

    DEFF Research Database (Denmark)

    Chan, JWYF; Maynard, Scott; Goodwin, PH

    1998-01-01

    A putative two-component signal transduction system was amplified and cloned from the plant pathogenic bacterium Xanthomonas campestris pv. phaseoli var. fuscans isolate BXPF65. The 620 bp amplified fragment was sequenced and analyzed with the BLAST Enhanced Alignment Utility (BEAUTY). BEAUTY ana...

  14. Global Pattern of Gene Expression of Xanthomonas axonopodis pv. glycines Within Soybean Leaves.

    Science.gov (United States)

    Chatnaparat, Tiyakhon; Prathuangwong, Sutruedee; Lindow, Steven E

    2016-06-01

    To better understand the behavior of Xanthomonas axonopodis pv. glycines, the causal agent of bacterial pustule of soybean within its host, its global transcriptome within soybean leaves was compared with that in a minimal medium in vitro, using deep sequencing of mRNA. Of 5,062 genes predicted from a draft genome of X. axonopodis pv. glycines, 534 were up-regulated in the plant, while 289 were down-regulated. Genes encoding YapH, a cell-surface adhesin, as well as several others encoding cell-surface proteins, were down-regulated in soybean. Many genes encoding the type III secretion system and effector proteins, cell wall-degrading enzymes and phosphate transporter proteins were strongly expressed at early stages of infection. Several genes encoding RND multidrug efflux pumps were induced in planta and by isoflavonoids in vitro and were required for full virulence of X. axonopodis pv. glycines, as well as resistance to soybean phytoalexins. Genes encoding consumption of malonate, a compound abundant in soybean, were induced in planta and by malonate in vitro. Disruption of the malonate decarboxylase operon blocked growth in minimal media with malonate as the sole carbon source but did not significantly alter growth in soybean, apparently because genes for sucrose and fructose uptake were also induced in planta. Many genes involved in phosphate metabolism and uptake were induced in planta. While disruption of genes encoding high-affinity phosphate transport did not alter growth in media varying in phosphate concentration, the mutants were severely attenuated for growth in soybean. This global transcriptional profiling has provided insight into both the intercellular environment of this soybean pathogen and traits used by X. axonopodis pv. glycines to promote disease.

  15. Genetic diversity of Xanthomonas axonopodis pv. citri based on plasmid profile and pulsed field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Carvalho Flávia Maria de Souza

    2005-01-01

    Full Text Available Xanthomonas axonopodis pv. citri strains that cause disease in citrus were investigated by pulsed field and plasmid profile analysis. For the first method, genomic DNA was digested by the rare-cutting enzymes Xba I and Vsp I. The strains evaluated were collected in seven different States of Brazil and in Argentina, Bolivia, Paraguay and Uruguay. Genetic variability was found among strains of X. axonopodis pv. citri from different geographical areas Argentina, Bolivia and Uruguay, with similarities varying from 0.62 to 0.83. However, the strains collected in Brazil, despite being from different States, have shown a genetic similarity ranging from 0.83 to 1.00. Cluster analysis showed a relationship between genomic similarity and geographical origin of the strains. Plasmids were observed in all strains, with a total of five different plasmids, with sizes between 57.7 and 83.0 kilobases. The 72.6 kb plasmid was the most frequent, present in 15 out of 22 strains, while the 68.1 kb plasmid was observed in two strains only. Although the plasmid diversity detected in the present study was not very great, the X. axonopodis pv. citri strains evaluated showed a considerable degree of diversity with regard to this extrachromosomal genetic element.

  16. Science Letters:Differentiation of xanthomonads causing the bacterial leaf spot of poinsettia in China from the pathotype strain of Xanthomonas axonopodis pv. Poinsettiicola

    Institute of Scientific and Technical Information of China (English)

    LI Bin; XIE Guan-lin; SWINGS J.

    2005-01-01

    In October 2003, a new bacterial disease with symptoms similar to those caused by Xanthomonas axonopodis pv.poinsettiicola was observed on poinsettia leaves at a flower nursery in Zhejiang Province of China. Three Xanthomonas strains were isolated from infected plants and classified as X. axonopodis. They were differentiated from the pathotype strain LMG849 of X. axonopodis pv. poinsettiicola causing bacterial leaf spot of poinsettia by comparison of pathogenicity, substrate utilization and BOX-PCR genomic fingerprints.

  17. Genotipos de frijol (Phaseolus Vulgaris l. resistentes a Xanthomonas campestris pv. phaseoli de Mexico

    Directory of Open Access Journals (Sweden)

    Rosa Navarrete

    2000-01-01

    Full Text Available Genotipos de frijol (Phaseolus vulgaris L. resistentes a Xanthomonas campestris pv. phaseoli de México. Durante 1995 se evaluó la reacción de genotipos de frijol de diversos origenes a Xcp, bajo condiciones de invernadero en el Campo Experimental del Valle de México, del INIFAP. Se realizaron tres experimentos con a120, b44 y csiete genotipos de frijol. Las plantas se inocularon por corte con navajas en la etapa V3, a y b con una mezcla de nueve cepas de Xcp y el c, con cada una de siete cepas con diferente grado de patogenicidad. La severidad se evaluó 20 días después de la inoculación, por comparación con una escala visual de nueve grados. Los datos se analizaron bajo un diseño completamente al azar. En a, los genotipos que mostraron reacción de resistencia a Xcp fueron: A 36, A 475, G 5686, G 11867, Harowood, SEA 14, XAN 266, MCD 4012 y REN 27. En b los genotipos resistentes fueron: Sequía Durango, Taylor y XAN 30. En los experimentos anteriores la severidad de la enfermedad mostró una distribución normal, con el máximo número de genotipos en el grado de severidad cinco en a y seis en b. Los resultados obtenidos indican que el uso de mezclas de cepas de bacterias con diferente patogenicidad es eficiente para identificar genotipos de frijol resistentes a Xcp. Los genotipos resistentes identificados en el último experimento, mostraron respuesta diferencial e interacciones genotipo por cepa. REN 27 y SEA 14 mostraron resistencia a las cepas utilizadas

  18. Sobrevivência de Xanthomonas axonopodis pv. manihotis em manipueira sob condições ambientais Survival of Xanthomonas axonopodis pv. manihotis in "manipueira" under environmental conditions

    Directory of Open Access Journals (Sweden)

    Gustavo de Faria Theodoro

    2002-07-01

    Full Text Available O objetivo deste trabalho foi avaliar a sobrevivência de um isolado de Xanthomonas axonopodis pv. manihotis (Xam, resistente ao sulfato de estreptomicina, em manipueira incubada em condições ambientais, em três épocas (março, julho e outubro de 2000. Foram utilizados um meio de cultura semi-seletivo para o isolamento de X. axonopodis pv. manihotis e a técnica de reação de polimerase em cadeia (PCR ou de amplificação biológica (BIO-PCR. Foram determinados o pH e a acidez total da manipueira durante o período de incubação estudado. O isolado sobreviveu por um período inferior a 24 horas, nas três épocas do ano. A técnica de PCR ou BIO-PCR não foi eficaz em monitorar a sobrevivência do isolado em manipueira, pois apresentou resultados contraditórios e não confiáveis. Observou-se queda do pH e aumento da acidez total da manipueira incubada nas condições estudadas, que pode explicar o comportamento da sobrevivência de Xam em manipueira.The objective of this work was to evaluate the survival of a Xanthomonas axonopodis pv. manihotis (Xam strain, resistant to streptomycin sulfate, in "manipueira" (cassava residue incubated under environmental conditions, in three periods of the year (March, July and October 2000. A semi-selective culture medium and the polymerase chain reaction (PCR or biological amplification (BIO-PCR methods were used. The pH and the total acidity of the "manipueira" were determined during the incubation period. The strain survived less than 24 hours in the three periods of the year. The PCR or BIO-PCR method was not effective in monitoring the strain survival in "manipueira", as it showed contradictory and unreliable results. An increase in total acidity and a decrease in pH of the "manipueira" were observed, explaining the survival behavior of Xam strain.

  19. Effect of aqueous extract from turmeric (Curcuma longa on Xanthomonas axonopodis pv. manihotis/ Efeito do extrato aquoso de cúrcuma (Curcuma longa em Xanthomonas axonopodis pv. manihotis

    Directory of Open Access Journals (Sweden)

    Gilmar Franzener

    2006-06-01

    Full Text Available The control of Xanthomonas axonopodis pv. manihotis was evaluated in vitro by using aqueous extract of four turmeric genotypes from Jaboticabal-SP, Mara Rosa-GO, Maringá-PR and Mercedes-PR, as well as in vivo, by treatment of infected cassava stems and their cultivation at field conditions. The results showed that in vitro experiment, turmeric extract inhibited completely the bacteria growth in the concentration of 10% for the genotype from Mercedes, while for the Jaboticabal’s turmeric there was a total control at 15% and for Mara Rosa at 20%. Turmeric genotype from Maringá did not show full inhibition of the bacterial growth in none of the extract concentrations used. At field conditions, sproutings were extremely low, due to the stems infection degree. Turmeric extract at 10%, from Mercedes, was harmful for the cassava, reducing stand regarding the control treatments. Possibly there was a direct toxic action on the plant physiology or susceptibility induction. But in the concentration of 1% of turmeric from Maringá, there was no statistical difference in relation to the control treatment for the plant stand. The chemical control was not completely efficient. There was no statistical difference among treatments for both severity and productivity. The results indicate that, although presenting antibacterial activity to X. axonopodis pv. manihotis, the turmeric extracts, in the used concentrations, did not present curative effect in cassava stems infected with the pathogen.Avaliou-se o controle in vitro de Xanthomonas axonopodis pv. manihotis mediante o uso de extrato aquoso de quatro genótipos de cúrcuma provenientes de cultivos de Jaboticabal-SP, Mara Rosa-GO, Maringá-PR e Mercedes-PR, bem como o efeito curativo, através do tratamento de manivas de mandioca infectadas com o patógeno e plantio em condições de campo. No experimento in vitro, o extrato de cúrcuma causou inibição total do crescimento da bactéria, na concentra

  20. CHARACTERIZATION OF XANTHOMONAS AXONOPODIS PV. PUNICAE ISOLATES FROM WESTERN MAHARASHTRA AND THEIR SENSITIVITY TO CHEMICAL TREATMENTS

    Directory of Open Access Journals (Sweden)

    K. S. RAGHUWANSHI

    2013-01-01

    Full Text Available Bacterial blight of pomegranate caused by Xanthomonas axonopodis pv. punicae is a major biotic constraint inpeninsular India. Field survey was undertaken in the major pomegranate growing regions of Western Maharashtra,which revealed the high prevalence of bacterial blight incidence in Solapur, Sangli and Nashik districts. Fourdifferent isolates of this pathogen were obtained from the highly infected plant materials collected during the fieldsurvey. X. axonopodis pv. punicae was detected from infected plant material and its identity was confirmed bymorphological, physiological, hypersensitive and pathogenicity tests. Nashik isolate was most virulent. On InterSimple Sequence Repeat (ISSR analysis they formed separate clusters with Akkalkot-Solapur isolate being mostdivergent, while Deola-Nashik and Sangamner-Ahmednagar isolates were most similar. Six chemical treatmentsshowed complete control under in vitro conditions while rest varied in their response to isolates. Completecontrol in all four isolates was observed with Bordeaux mixture (1%; captan (0.25% + Copper oxychloride(0.3%, captan (0.25% + copper hydroxide (0.3%, bromopol (500 ppm + copper oxychloride (0.3%,streptocycline (250 ppm + copper hydroxide (0.3%, streptocycline (500 ppm + copper hydroxide (0.3%during in vitro study

  1. Identification of differentially expressed genes of Xanthomonas axonopodis pv. citri by representational difference analysis of cDNA

    Directory of Open Access Journals (Sweden)

    Angela Mehta

    2005-03-01

    Full Text Available Xanthomonas axonopodis pv. citri is a phytopathogenic bacterium responsible for citrus canker, a serious disease which causes severe losses in citriculture around the world. In this study we report the differential expression of X. axonopodis pv. citri in response to specific treatments by using Representational Difference Analysis of cDNA (cDNA RDA. cDNAs from X. axonopodis pv. citri cultured in the presence of leaf extract of the host plant (Citrus sinensis, in vivo, as well as in the complex medium were hybridized against cDNA of the bacterium grown in the minimal medium. Sequencing of the difference products obtained after the second and third hybridizations revealed a total of 37 distinct genes identified by homology searches in the genome of X. axonopodis pv. citri. These genes were distributed in different functional categories, including genes that encode hypothetical proteins, genes involved in metabolism, cellular processes and pathogenicity, and mobile genetic elements. Most of these genes are likely related to growth and/or acquisition of nutrients in specific treatments whereas others might be important for the bacterium pathogenicity.

  2. A novel two-component response regulator links rpf with biofilm formation and virulence of Xanthomonas axonopodis pv. citri.

    Directory of Open Access Journals (Sweden)

    Tzu-Pi Huang

    Full Text Available Citrus bacterial canker caused by Xanthomonas axonopodis pv. citri is a serious disease that impacts citrus production worldwide, and X. axonopodis pv. citri is listed as a quarantine pest in certain countries. Biofilm formation is important for the successful development of a pathogenic relationship between various bacteria and their host(s. To understand the mechanisms of biofilm formation by X. axonopodis pv. citri strain XW19, the strain was subjected to transposon mutagenesis. One mutant with a mutation in a two-component response regulator gene that was deficient in biofilm formation on a polystyrene microplate was selected for further study. The protein was designated as BfdR for biofilm formation defective regulator. BfdR from strain XW19 shares 100% amino acid sequence identity with XAC1284 of X. axonopodis pv. citri strain 306 and 30-100% identity with two-component response regulators in various pathogens and environmental microorganisms. The bfdR mutant strain exhibited significantly decreased biofilm formation on the leaf surfaces of Mexican lime compared with the wild type strain. The bfdR mutant was also compromised in its ability to cause canker lesions. The wild-type phenotype was restored by providing pbfdR in trans in the bfdR mutant. Our data indicated that BfdR did not regulate the production of virulence-related extracellular enzymes including amylase, lipase, protease, and lecithinase or the expression of hrpG, rfbC, and katE; however, BfdR controlled the expression of rpfF in XVM2 medium, which mimics cytoplasmic fluids in planta. In conclusion, biofilm formation on leaf surfaces of citrus is important for canker development in X. axonopodis pv. citri XW19. The process is controlled by the two-component response regulator BfdR via regulation of rpfF, which is required for the biosynthesis of a diffusible signal factor.

  3. A LOV protein modulates the physiological attributes of Xanthomonas axonopodis pv. citri relevant for host plant colonization.

    Directory of Open Access Journals (Sweden)

    Ivana Kraiselburd

    Full Text Available Recent studies have demonstrated that an appropriate light environment is required for the establishment of efficient vegetal resistance responses in several plant-pathogen interactions. The photoreceptors implicated in such responses are mainly those belonging to the phytochrome family. Data obtained from bacterial genome sequences revealed the presence of photosensory proteins of the BLUF (Blue Light sensing Using FAD, LOV (Light, Oxygen, Voltage and phytochrome families with no known functions. Xanthomonas axonopodis pv. citri is a Gram-negative bacterium responsible for citrus canker. The in silico analysis of the X. axonopodis pv. citri genome sequence revealed the presence of a gene encoding a putative LOV photoreceptor, in addition to two genes encoding BLUF proteins. This suggests that blue light sensing could play a role in X. axonopodis pv. citri physiology. We obtained the recombinant Xac-LOV protein by expression in Escherichia coli and performed a spectroscopic analysis of the purified protein, which demonstrated that it has a canonical LOV photochemistry. We also constructed a mutant strain of X. axonopodis pv. citri lacking the LOV protein and found that the loss of this protein altered bacterial motility, exopolysaccharide production and biofilm formation. Moreover, we observed that the adhesion of the mutant strain to abiotic and biotic surfaces was significantly diminished compared to the wild-type. Finally, inoculation of orange (Citrus sinensis leaves with the mutant strain of X. axonopodis pv. citri resulted in marked differences in the development of symptoms in plant tissues relative to the wild-type, suggesting a role for the Xac-LOV protein in the pathogenic process. Altogether, these results suggest the novel involvement of a photosensory system in the regulation of physiological attributes of a phytopathogenic bacterium. A functional blue light receptor in Xanthomonas spp. has been described for the first time, showing

  4. Multiplexed lateral flow microarray assay for detection of citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis pv citri

    Energy Technology Data Exchange (ETDEWEB)

    Cary; R. Bruce (Santa Fe, NM); Stubben, Christopher J. (Los Alamos, NM)

    2011-03-22

    The invention provides highly sensitive and specific assays for the major citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis, including a field deployable multiplexed assay capable of rapidly assaying for both pathogens simultaneously. The assays are directed at particular gene targets derived from pathogenic strains that specifically cause the major citrus diseases of citrus variegated chlorosis (Xylella fastidiosa 9a5c) and citrus canker (Xanthomonas axonopodis pv citri). The citrus pathogen assays of the invention offer femtomole sensitivity, excellent linear dynamic range, and rapid and specific detection.

  5. Reaction of cassava’s germoplasm to Xanthomonas axonopodis pv. manihots/ Reação de germoplasma de mandioca a Xanthomonas axonopodis pv. manihots

    Directory of Open Access Journals (Sweden)

    Benjamim de Melo

    2007-07-01

    Full Text Available The cassava is presented as an important stach source, mainly in the tropics. The bacteriosis disease caused by Xanthomonas axonopodis p.v. manihots is the most important disease of this culture and its damage can achieve 30% of the production, or even more. This work objectified to evaluate, in green house condition the reaction of “mandioca mansa” and the “mandioca brava” cassava’s germoplasma to the two isolates of Xanthomonas axonopodis p.v. manihots. Trials were developed at the Instituto de Ciências Agrárias da Universidade Federal de Uberlândia. The plants had been inoculated by seasor’s cuttings of three central leaflets in three completely opened new leaves, following by insertion of a little wood stick at the oldest leaf’s axel, using a bacterial suspension at 2x109u.f.c. mL-1. The inoculation happened at the 42nd day after planting and the evaluation at the 41st day after inoculation. The evaluation criteria were: notes of visual symptoms in the aerial part, percentages defoliation and systemic infection of the stalk. The results showed the efficiency of the evaluation criteria applied at this work for the isolates virulence study. The Uberlândia isolate was more virulent to “mandioca mansa” cassava cultivars and the Lavras isolate was more virulent to “mandioca brava” cassava cultivars. That indicates the need of using isolates from the region where the germoplasm will be cultivated. Considering the germoplasm resistance reaction analysis, both the sistemic infection precentage and the defoliation criteria presented as very effective. Oustanding behavior was observed for the Vassoura, Amarela, Vermelha and Castelinho cultivars and for the CPAC88-11 clone.A mandioca apresenta-se como importante fonte de carboidratos, principalmente nos trópicos. A bacteriose causada por Xanthomonas axonopodis p.v. manihots é a doença mais importante desta cultura e seus danos podem chegar a 30% ou mais na produção. Este

  6. Crystal Structure of the FAD-Containing Ferredoxin-NADP+ Reductase from the Plant Pathogen Xanthomonas axonopodis pv. citri

    Directory of Open Access Journals (Sweden)

    María Laura Tondo

    2013-01-01

    Full Text Available We have solved the structure of ferredoxin-NADP(H reductase, FPR, from the plant pathogen Xanthomonas axonopodis pv. citri, responsible for citrus canker, at a resolution of 1.5 Å. This structure reveals differences in the mobility of specific loops when compared to other FPRs, probably unrelated to the hydride transfer process, which contributes to explaining the structural and functional divergence between the subclass I FPRs. Interactions of the C-terminus of the enzyme with the phosphoadenosine of the cofactor FAD limit its mobility, thus affecting the entrance of nicotinamide into the active site. This structure opens the possibility of rationally designing drugs against the X. axonopodis pv. citri phytopathogen.

  7. The molybdate-binding protein (ModA) of the plant pathogen Xanthomonas axonopodis pv. citri.

    Science.gov (United States)

    Balan, Andrea; Santacruz, Carolina P; Moutran, Alexandre; Ferreira, Rita C C; Medrano, Francisco J; Pérez, Carlos A; Ramos, Carlos H I; Ferreira, Luís C S

    2006-12-01

    The modABC operon of phytopathogen Xanthomonas axonopodis pv. citri (X. citri) encodes a putative ABC transporter involved in the uptake of the molybdate and tungstate anions. Sequence analyses showed high similarity values of ModA orthologs found in X. campestris pv. campestris (X. campestris) and Escherichia coli. The X. citri modA gene was cloned in pET28a and the recombinant protein, expressed in the E. coli BL21 (DE3) strain, purified by immobilized metal affinity chromatography. The purified protein remained soluble and specifically bound molybdate and tungstate with K(d) 0.29+/-0.12 microM and 0.58+/-0.14 microM, respectively. Additionally binding of molybdate drastically enhanced the thermal stability of the recombinant ModA as compared to the apoprotein. This is the first characterization of a ModA ortholog expressed by a phytopathogen and represents an important tool for functional, biochemical and structural analyses of molybdate transport in Xanthomonas species.

  8. Genomic insights into the evolutionary origin of Xanthomonas axonopodis pv. citri and its ecological relatives.

    Science.gov (United States)

    Midha, Samriti; Patil, Prabhu B

    2014-10-01

    Xanthomonas axonopodis pv. citri (Xac) is the causal agent of citrus bacterial canker (CBC) and is a serious problem worldwide. Like CBC, several important diseases in other fruits, such as mango, pomegranate, and grape, are also caused by Xanthomonas pathovars that display remarkable specificity toward their hosts. While citrus and mango diseases were documented more than 100 years ago, the pomegranate and grape diseases have been known only since the 1950s and 1970s, respectively. Interestingly, diseases caused by all these pathovars were noted first in India. Our genome-based phylogenetic studies suggest that these diverse pathogens belong to a single species and these pathovars may be just a group of rapidly evolving strains. Furthermore, the recently reported pathovars, such as those infecting grape and pomegranate, form independent clonal lineages, while the citrus and mango pathovars that have been known for a long time form one clonal lineage. Such an understanding of their phylogenomic relationship has further allowed us to understand major and unique variations in the lineages that give rise to these pathovars. Whole-genome sequencing studies including ecological relatives from their putative country of origin has allowed us to understand the evolutionary history of Xac and other pathovars that infect fruits.

  9. COMPARING INOCULATION METHODS TO EVALUATE THE GROWTH OF Xanthomonas axonopodis pv. manihotis ON CASSAVA PLANTS

    Directory of Open Access Journals (Sweden)

    Alejandra MUÑOZ BODNAR

    2015-01-01

    Full Text Available Xanthomonas axonopodis pv. manihotis (Xam es el agente causal del tizón bacteriano de la yuca, una de las principales enfermedades de los cultivos de yuca en América del Sur y África. Hasta ahora, el desarrollo de la enfermedad se mide a través de AUDPC (Area Under Disease Progress curve, pero no hay disponibles métodos cuantitativos fiables, esto debido posiblemente a la alta variabilidad del crecimiento bacteriano en la planta. Para establecer un método exacto para la cuantificación bacteriana durante el curso de la infección Xam dentro de los tejidos del huésped, se analizaron las poblaciones de bacterias sobre tallo y hojas, así como corte de hojas de las variedades de yuca MCOL1522 y SG107-35 con la cepa virulenta CIO151 Xam. En esta investigación se muestra que el movimiento de las bacterias a lo largo de los tejidos y especialmente en las hojas es estocástico. Por otra parte, hemos podido demostrar el crecimiento diferencial de la cepa virulenta Xam CIO151 tras la punción al tallo y la cuantificación de la bacteria a 6 cm de distancia del punto de inoculación de dos variedades que presentan niveles contrastantes de susceptibilidad.

  10. Temperature Sensitivity of the Hypersensitive Response of Bell Pepper to Xanthomonas axonopodis pv. vesicatoria.

    Science.gov (United States)

    Romero, A M; Kousik, C S; Ritchie, D F

    2002-02-01

    ABSTRACT When bacterial spot-resistant pepper plants carrying resistance gene Bs2 and infiltrated with incompatible strains of Xanthomonas axonopodis pv. vesicatoria carrying a functional avrBs2 gene (races P1 and P3) were incubated at 32 degrees C, they exhibited an electrolyte leakage and bacterial multiplication pattern in planta similar to that obtained with a compatible strain (race P4) carrying a nonfunctional avrBs2 gene. They also developed disease-like symptoms. Pretreatment of incompatible bacteria at 32 degrees C before infiltration caused a delay in electrolyte leakage less pronounced than that caused by exposing plants to 32 degrees C. Also, plants had to be exposed to 32 degrees C for an hour prior to inoculation to increase symptom expression. These data suggest that the Bs2 gene is temperature sensitive. In other experiments, the avrBs1-Bs1 interaction appeared to be the most heat tolerant and thus the least likely to revert to compatible, whereas the avrBs3-Bs3 interaction had an intermediate sensitivity to elevated temperatures.

  11. Pathogenic Interactions Between Xanthomonas axonopodis pv. citri and Cultivars of Pummelo (Citrus grandis).

    Science.gov (United States)

    Shiotani, H; Ozaki, K; Tsuyumu, S

    2000-12-01

    ABSTRACT The aggressiveness of strains of Xanthomonas axonopodis pv. citri on seven Citrus species, including Citrus sinensis (navel orange), C. paradisi (grapefruit), C. unshiu (Satsuma mandarin), C. junos (Yuzu), C. aurantifolia ('Mexican' lime), C. tachibana (Tachibana), and C. grandis (pummelo: 'Otachibana', 'Banpeiyu', and 'Anseikan'), were assessed by comparing lesion expansion and growth in planta, using a prick inoculation method. The existence of two groups distinct in aggressiveness was demonstrated on the pummelo cultivars, whereas the remaining species tested were uniformly susceptible. The two groups of strains were distinct in lesion expansion and growth in planta; however, both caused canker lesions on the 'Otachibana' pummelo. The sensitivity of the bacterial strains to phages Cp1 and Cp2 was associated with differences in aggressiveness. Namely, all the strains sensitive to Cp2 but resistant to Cp1 were aggressive to 'Otachibana', whereas all the strains sensitive to Cp1 but resistant to Cp2 were weakly aggressive. When a repetitive sequence-based polymerase chain reaction amplification was carried out by enterobacterial repetitive intergeneric consensus (ERIC) sequences (ERIC1R and ERIC2) as the primers, these two groups were also distinguishable by the presence or absence of a 1.8-kb DNA fragment among otherwise identical fragments. The 1.8-kb fragment was amplified only from the strains aggressive to C. grandis.

  12. Effect of aqueous extract from turmeric (Curcuma longa) on Xanthomonas axonopodis pv. manihotis/
    Efeito do extrato aquoso de cúrcuma (Curcuma longa) em Xanthomonas axonopodis pv. manihotis

    OpenAIRE

    Gilmar Franzener; Kátia Regina Freitas Schwan-Estrada; Ricardo Montalván Del Águila; José Renato Stangarlin; Roberto Luiz Portz; Odair José Kuhn

    2006-01-01

    The control of Xanthomonas axonopodis pv. manihotis was evaluated in vitro by using aqueous extract of four turmeric genotypes from Jaboticabal-SP, Mara Rosa-GO, Maringá-PR and Mercedes-PR, as well as in vivo, by treatment of infected cassava stems and their cultivation at field conditions. The results showed that in vitro experiment, turmeric extract inhibited completely the bacteria growth in the concentration of 10% for the genotype from Mercedes, while for the Jaboticabal’s turmeric there...

  13. Characterization of bacteriophages Cp1 and Cp2, the strain-typing agents for Xanthomonas axonopodis pv. citri.

    Science.gov (United States)

    Ahmad, Abdelmonim Ali; Ogawa, Megumi; Kawasaki, Takeru; Fujie, Makoto; Yamada, Takashi

    2014-01-01

    The strains of Xanthomonas axonopodis pv. citri, the causative agent of citrus canker, are historically classified based on bacteriophage (phage) sensitivity. Nearly all X. axonopodis pv. citri strains isolated from different regions in Japan are lysed by either phage Cp1 or Cp2; Cp1-sensitive (Cp1(s)) strains have been observed to be resistant to Cp2 (Cp2(r)) and vice versa. In this study, genomic and molecular characterization was performed for the typing agents Cp1 and Cp2. Morphologically, Cp1 belongs to the Siphoviridae. Genomic analysis revealed that its genome comprises 43,870-bp double-stranded DNA (dsDNA), with 10-bp 3'-extruding cohesive ends, and contains 48 open reading frames. The genomic organization was similar to that of Xanthomonas phage phiL7, but it lacked a group I intron in the DNA polymerase gene. Cp2 resembles morphologically Escherichia coli T7-like phages of Podoviridae. The 42,963-bp linear dsDNA genome of Cp2 contained terminal repeats. The Cp2 genomic sequence has 40 open reading frames, many of which did not show detectable homologs in the current databases. By proteomic analysis, a gene cluster encoding structural proteins corresponding to the class III module of T7-like phages was identified on the Cp2 genome. Therefore, Cp1 and Cp2 were found to belong to completely different virus groups. In addition, we found that Cp1 and Cp2 use different molecules on the host cell surface as phage receptors and that host selection of X. axonopodis pv. citri strains by Cp1 and Cp2 is not determined at the initial stage by binding to receptors.

  14. COMPARING INOCULATION METHODS TO EVALUATE THE GROWTH OF Xanthomonas axonopodis pv. manihotis ON CASSAVA PLANTS

    Directory of Open Access Journals (Sweden)

    Alejandra Muñoz Bodnar

    2014-11-01

    Full Text Available Xanthomonas axonopodis pv. manihotis (Xam is the causal agent of cassava bacterial blight (CBB, a major disease for cassava crops in South America and Africa. Until now the development of the disease is measured via AUDPC (Area Under Disease Progress Curve but no reliable quantitative methods are available probably due to high variability of bacterial growth in planta. To establish an accurate method for bacterial quantification during the course of Xam infection within the host tissues, we analyzed bacterial populations upon stem and leaf-puncturing as well as leaf-clipping of cassava varieties MCOL1522 and SG107-35 challenged with the virulent Xam strain CIO151. Here, we show that the movement of bacteria along the tissues and especially in leaves is stochastic. Moreover, we were able to demonstrate differential growth of virulent Xam strain CIO151 upon stem-puncturing and quantification of bacteria 6 cm. away from the inoculation point of two varieties displaying contrasting levels of susceptibility.RESUMEN Normal 0 21 false false false ES-CO X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Xanthomonas axonopodis pv. manihotis (Xam es el agente causal del tizón bacteriano de la yuca, una de las principales enfermedades de los cultivos de yuca en América del Sur y África. Hasta ahora, el desarrollo de la

  15. Differential expression of pathogenicity- and virulence-related genes of Xanthomonas axonopodis pv. citri under copper stress

    Directory of Open Access Journals (Sweden)

    Ana Carolina Basílio Palmieri

    2010-01-01

    Full Text Available In this study, we used real-time quantitative PCR (RT-qPCR to evaluate the expression of 32 genes of Xanthomonas axonopodis pv. citri related to pathogenicity and virulence that are also involved in copper detoxification. Nearly all of the genes were up-regulated, including copA and copB. Two genes homologous to members of the type II secretion system (xcsH and xcsC and two involved in the degradation of plant cell wall components (pglA and pel were the most expressed in response to an elevated copper concentration. The type II secretion system (xcs operon and a few homologues of proteins putatively secreted by this system showed enhanced expression when the bacteria were exposed to a high concentration of copper sulfate. The enhanced expression of the genes of secretion II system during copper stress suggests that this pathway may have an important role in the adaptative response of X. axonopodis pv. citri to toxic compounds. These findings highlight the potential role of these genes in attenuating the toxicity of certain metals and could represent an important means of bacterial resistance against chemicals used to control diseases.

  16. Crystallization, data collection and phasing of the molybdate-binding protein of the phytopathogen Xanthomonas axonopodis pv. citri

    Energy Technology Data Exchange (ETDEWEB)

    Santacruz, C. P.; Balan, A.; Ferreira, L. C. S. [Departamento de Microbiologia, Instituto de Ciências Biomédicas II, Universidade de São Paulo, São Paulo, SP (Brazil); Barbosa, J. A. R. G., E-mail: joao@lnls.br [Centro de Biologia Molecular e Estrutural (CeBiMe), Laboratório Nacional de Luz Síncrotron (LNLS), CP 6192, Campinas, SP 13084-971 (Brazil); Departamento de Microbiologia, Instituto de Ciências Biomédicas II, Universidade de São Paulo, São Paulo, SP (Brazil)

    2006-03-01

    The molybdate-binding protein (ModA) from X. axonopodis pv. citri was crystallized with sodium molybdate in the presence of PEG or sulfate. The crystal diffracted to a maximum resolution of 1.7 Å and belongs to the orthorhombic space group C222{sub 1,} with unit-cell parameters a = 68.15, b = 172.14, c = 112.04 Å. Xanthomonas axonopodis pv. citri ModA protein is the ABC periplasmic binding component responsible for the capture of molybdate. The protein was crystallized with sodium molybdate using the hanging-drop vapour-diffusion method in the presence of PEG or sulfate. X-ray diffraction data were collected to a maximum resolution of 1.7 Å using synchrotron radiation. The crystal belongs to the orthorhombic space group C222{sub 1}, with unit-cell parameters a = 68.15, b = 172.14, c = 112.04 Å. The crystal structure was solved by molecular-replacement methods and structure refinement is in progress.

  17. Identification of Pathotypes of Xanthomonas axonopodis pv. manihotis in Africa and Detection of Quantitative Trait Loci and Markers for Resistance to Bacterial Blight of Cassava.

    Science.gov (United States)

    Wydra, K; Zinsou, V; Jorge, V; Verdier, V

    2004-10-01

    ABSTRACT Cassava suffers from bacterial blight attack in all growing regions. Control by resistance is unstable due to high genotype-environment interactions. Identifying genes for resistance to African strains of Xanthomonas axonopodis pv. manihotis can support breeding efforts. Five F(1) cassava genotypes deriving from the male parent 'CM2177-2' and the female parent 'TMS30572' were used to produce 111 individuals by backcrossing to the female parent. In all, 16 genotypes among the mapping population were resistant to stem inoculation by four strains of X. axonopodis pv. manihotis from different locations in Africa, and 19 groups with differential reactions to the four strains were identified, suggesting that the strains represent different pathotypes. Four genotypes were resistant to leaf inoculation, and three were resistant to both stem and leaf inoculations. Genotypes with susceptible, moderately resistant, and resistant reactions after leaf and stem inoculation partly differed in their reactions on leaves and stems. Based on the genetic map of cassava, single-markeranalysis of disease severity after stem-puncture inoculation was performed. Eleven markers were identified, explaining between 16 and 33.3% of phenotypic variance of area under disease progress curve. Five markers on three and one linkage groups from the female- and male-derived framework of family CM8820, respectively, seem to be weakly associated with resistance to four strains of X. axonopodis pv. manihotis. Based on the segregation of alleles from the female of family CM8873, one marker was significantly associated with resistance to two X. axonopodis pv. manihotis strains, GSPB2506 and GSPB2511, whereas five markers were not linked to any linkage group. The quantitative trait loci (QTL) mapping results also suggest that the four African strains belong to four different pathotypes. The identified pathotypes should be useful for screening for resistance, and the QTL and markers will support

  18. Monitoramento da expressão gênica de Xanthomonas axonopodis pv. citri em diferentes condições ambientais

    OpenAIRE

    2003-01-01

    The bacterium Xanthomonas axonopodis pv. citri is a pathogen causing citric canker that compromises part of the orange production in the State of São Paulo, with negative consequences for the economy of the State and the Country. For the future control of citric canker, several investigators participated in the Xanthomonas Genome Project in order to determine the gene set of this bacterium and to contribute to the identification of the genes involved in its pathogenicity. In this respect, the...

  19. Defense-Related Responses in Fruit of the Nonhost Chili Pepper against Xanthomonas axonopodis pv. glycines Infection

    Directory of Open Access Journals (Sweden)

    Sung Pae Chang

    2016-08-01

    Full Text Available Xanthomonas axonopodis pv. glycines (Xag is a necrotrophic bacterial pathogen of the soybean that causes bacterial pustules and is a nonhost pathogen of the chili pepper. In the current study, chili pepper fruit wound inoculated in planta with Xag 8ra formed necrotic lesions on the fruit surface and induced several structural and chemical barriers systemically in the fruit tissue. The initial defense response included programmed cell death of necrotizing and necrotized cells, which was characterized by nuclear DNA cleavage, as detected by TUNEL-confocal laser scanning microscopy (CLSM, and phosphatidylserine exposure on cell walls distal to the infection site, as detected by Annexin V FLUOS-CLSM. These two responses may facilitate cell killing and enhance transportation of cell wall materials used for cell wall thickening, respectively. The cells beneath the necrotic tissue were enlarged and divided to form periclinal cell walls, resulting in extensive formation of several parallel boundary layers at the later stages of infection, accompanying the deposition of wall fortification materials for strengthening structural defenses. These results suggest that nonhost resistance of chili pepper fruit against the nonhost necrotrophic pathogen Xag 8ra is activated systematically from the initial infection until termination of the infection cycle, resulting in complete inhibition of bacterial pathogenesis by utilizing organ-specific in situ physiological events governed by the expression of genes in the plant fruit organ.

  20. Crystallographic structure and substrate-binding interactions of the molybdate-binding protein of the phytopathogen Xanthomonas axonopodis pv. citri.

    Science.gov (United States)

    Balan, Andrea; Santacruz-Pérez, Carolina; Moutran, Alexandre; Ferreira, Luís Carlos Souza; Neshich, Goran; Gonçalves Barbosa, João Alexandre Ribeiro

    2008-02-01

    In Xanthomonas axonopodis pv. citri (Xac or X. citri), the modA gene codes for a periplasmic protein (ModA) that is capable of binding molybdate and tungstate as part of the ABC-type transporter required for the uptake of micronutrients. In this study, we report the crystallographic structure of the Xac ModA protein with bound molybdate. The Xac ModA structure is similar to orthologs with known three-dimensional structures and consists of two nearly symmetrical domains separated by a hinge region where the oxyanion-binding site lies. Phylogenetic analysis of different ModA orthologs based on sequence alignments revealed three groups of molybdate-binding proteins: bacterial phytopathogens, enterobacteria and soil bacteria. Even though the ModA orthologs are segregated into different groups, the ligand-binding hydrogen bonds are mostly conserved, except for Archaeglobus fulgidus ModA. A detailed discussion of hydrophobic interactions in the active site is presented and two new residues, Ala38 and Ser151, are shown to be part of the ligand-binding pocket.

  1. Construction of EGFP-labeling system for visualizing the infection process of Xanthomonas axonopodis pv. citri in planta.

    Science.gov (United States)

    Liu, Li-Ping; Deng, Zi-Niu; Qu, Jin-Wang; Yan, Jia-Wen; Catara, Vittoria; Li, Da-Zhi; Long, Gui-You; Li, Na

    2012-09-01

    Xanthomonas axonopodis pv. citri (Xac) is the causal agent of citrus bacterial canker, an economically important disease to world citrus industry. To monitor the infection process of Xac in different citrus plants, the enhanced green florescent protein (EGFP) visualizing system was constructed to visualize the propagation and localization in planta. First, the wild-type Xac was isolated from the diseased leaves of susceptible 'Bingtang' sweet orange, and then the isolated Xac was labeled with EGFP by triparental mating. After PCR identification, the growth kinetics and pathogenicity of the transformants were analyzed in comparison with the wild-type Xac. The EGFP-labeled bacteria were inoculated by spraying on the surface and infiltration in the mesophyll of 'Bingtang' sweet orange leaves. The bacterial cell multiplication and diffusion processes were observed directly under confocal laser scanning microscope at different intervals after inoculation. The results indicated that the EGFP-labeled Xac releasing clear green fluorescence light under fluorescent microscope showed the infection process and had the same pathogenicity as the wild type to citrus. Consequently, the labeled Xac demonstrated the ability as an efficient tool to monitor the pathogen infection.

  2. Cloning of Genomic DNA Flanking Transposon in the Nonpathogenic Mutant of Xanthomonas axonopodis pv. glycines M715

    Directory of Open Access Journals (Sweden)

    ALINA AKHDIYA RUSMANA

    2005-06-01

    Full Text Available The objective of this work is to clone flanking DNA derived from Tn-5 mutagenesis of wild type strain Xanthomonas axonopodis pv. glycines as first step to clone and to identify the gene involved in pathogenicity mechanism. We have localized the flanking DNA fragment from a nonpathogenic mutant of Xag M715. Southern hybridization analysis using 2.8 kb EcoRI from pYR103 as a probe showed that the fragment is located within 2.0 kb PstI fragment. A 0.7 kb flanking DNA was amplified using inverse PCR technique, and inserted into pGEM-T Easy vector generating a 3.7 kb recombinant plasmid (pAA01. Southern hybridization analysis of the wild type (YR32 with pAA01 as a probe indicated a hybridization signal located at approximately 3.0 kb PstI fragment. DNA sequence analysis revealed that the DNA fragment has a 64% identity to a vir gene of Bacillus anthracis.

  3. LA PROTEÍNA PTHB DE Xanthomonas axonopodis pv. Manihotis ES AUTOACTIVA EN ENSAYOS DE DOBLE HÍBRIDO The PthB Protein from Xanthomonas axonopodis pv. Manihotis is an Autoactive in Yeast Two-Hybrid Assays

    Directory of Open Access Journals (Sweden)

    JULIANA GIL

    Full Text Available La bacteriosis vascular de yuca producida por la bacteria Xanthomonas axonopodis pv. manihotis (Xam es una enfermedad limitante para la producción de yuca. Dentro de los primeros factores de patogenicidad identificados en esta bacteria se encuentra el gen PthB. La proteína PthB pertenece a la familia de efectores PthA/AvrBs3, que se caracterizan por presentar dominios NLS (Nuclear Localization Signal y un dominio AAD (Acidic Activation Domain, lo cual sugiere que estas proteínas actúan como factores de transcripción. La identificación de las proteínas de yuca que interactúan con PthB permitiría dar luces sobre la función de esta proteína en la patogenicidad de esta bacteria. En este trabajo se clonó PthB en una fusión traduccional con el BD (Binding Domain del factor de transcripción GAL4. Después de transformar este constructo en una cepa de levadura, se observó autoactivación de los genes reporteros, incluso a concentraciones altas de 3-AT. La eliminación del primer, segundo o de los dos NLS y del AAD no eliminaron la capacidad de autoactivación de los genes reporteros mediada por PthB. Estos resultados indican la imposibilidad de su utilización en un tamizaje de una librería de ADNc de yuca para identificar las proteínas que interactúan con PthB.Cassava bacterial blight disease is caused by the gram-negative bacteria Xanthomonas axonopodis pv. manihotis (Xam, and constitutes one of the most important constraints for cassava production. One of the first determinants of pathogenicity identified in this bacterium is the PthB gene. The PthB protein belongs to the PthA/AvrBs3 family, characterized by the presence of Nuclear Localization Signal (NLS and Acidic Activation (AAD domains, suggesting that these proteins are transcription factors. The identification of cassava proteins interacting with PthB could give insights about the function of this protein in the pathogenicity of this bacterium. In this work we cloned PthB in

  4. In silico identification of potential chaperone genes that belong to type III and type IV secretion systems in Xanthomonas axonopodis pv citri

    Directory of Open Access Journals (Sweden)

    Letícia Khater

    2005-01-01

    Full Text Available The secretion of bacterial virulence factors and flagellar components requires the assistance of specific type III and flagellar chaperones. Standard computational annotation of the genome of Xanthomonas axonopodis pv citri, a plant pathogen that causes citrus canker, initially did not identify any genes belonging to these chaperone categories since the primary sequence homology between them was very low. However, in a search for hypothetical proteins with characteristics similar to these chaperones, we have now identified 30 chromosomal and 10 plasmidial potential genes encoding chaperones belonging to types III/IV, and flagellar secretion systems in this organism. The significance of these findings is discussed.

  5. Identification of pathotypes of Xanthomonas axonopodis pv. manihotis in Africa and detection of quantitative trait loci and markers for resistance to bacterial blight of Cassava

    OpenAIRE

    Wydra, Kerstin; Zinsou, Valerien; Jorge, Véronique; Verdier, Valérie

    2004-01-01

    Cassava suffers from bacterial blight attack in all growing regions. Control by resistance is unstable due to high genotype–environment interactions. Identifying genes for resistance to African strains of Xanthomonas axonopodis pv. manihotis can support breeding efforts. Five F1 cassava genotypes deriving from the male parent ‘CM2177-2’ and the female parent ‘TMS30572’ were used to produce 111 individuals by backcrossing to the female parent. In all, 16 genotypes among the mapping population ...

  6. La proteína PthB de Xanthomonas axonopodis pv. manihotis es autoactiva en ensayos de doble hibrido

    Directory of Open Access Journals (Sweden)

    Gil Juliana

    2011-04-01

    Full Text Available La bacteriosis vascular de yuca producida por la bacteria Xanthomonas axonopodis pv. manihotis (Xam es uno de los factores limitantes para la producción de yuca. Dentro de los primeros factores de patogenicidad identificados en esta bacteria se encuentra el gen pthB. La proteína PthB pertenece a la familia de efectores PthA/AvrBs3, que se caracterizan por presentar dominios NLS (Nuclear Localization Signal y un dominio AAD (Acidic Activation Domain, lo cual sugiere que estas proteínas actúan como factores de transcripción. La identificación de las proteínas de yuca que interactúan con PthB permitiría dar luces sobre la función de esta proteína en la patogenicidad de esta bacteria. En este trabajo se clonó pthB en una fusión traduccional con el BD (Binding Domain del factor de transcripción GAL4. Después de transformar este constructo en una cepa de levadura, se observó autoactivación de los genes reporteros, incluso a concentraciones altas de 3-AT. La eliminación del primer, segundo o de los dos NLS y del AAD no eliminaron la capacidad de autoactivación de los genes reporteros mediada por PthB. Estos resultados indican la imposibilidad de su utilización en un tamizaje de una librería de ADNc de yuca para identificar las proteínas que interactúan con PthB.

  7. Genome-wide mutagenesis of Xanthomonas axonopodis pv. citri reveals novel genetic determinants and regulation mechanisms of biofilm formation.

    Directory of Open Access Journals (Sweden)

    Jinyun Li

    Full Text Available Xanthomonas axonopodis pv. citri (Xac causes citrus canker disease, a major threat to citrus production worldwide. Accumulating evidence suggests that the formation of biofilms on citrus leaves plays an important role in the epiphytic survival of this pathogen prior to the development of canker disease. However, the process of Xac biofilm formation is poorly understood. Here, we report a genome-scale study of Xac biofilm formation in which we identified 92 genes, including 33 novel genes involved in biofilm formation and 7 previously characterized genes, colR, fhaB, fliC, galU, gumD, wxacO, and rbfC, known to be important for Xac biofilm formation. In addition, 52 other genes with defined or putative functions in biofilm formation were identified, even though they had not previously reported been to be associated with biofilm formation. The 92 genes were isolated from 292 biofilm-defective mutants following a screen of a transposon insertion library containing 22,000 Xac strain 306 mutants. Further analyses indicated that 16 of the novel genes are involved in the production of extracellular polysaccharide (EPS and/or lipopolysaccharide (LPS, 7 genes are involved in signaling and regulatory pathways, and 5 genes have unknown roles in biofilm formation. Furthermore, two novel genes, XAC0482, encoding a haloacid dehalogenase-like phosphatase, and XAC0494 (designated as rbfS, encoding a two-component sensor protein, were confirmed to be biofilm-related genes through complementation assays. Our data demonstrate that the formation of mature biofilm requires EPS, LPS, both flagellum-dependent and flagellum-independent cell motility, secreted proteins and extracellular DNA. Additionally, multiple signaling pathways are involved in Xac biofilm formation. This work is the first report on a genome-wide scale of the genetic processes of biofilm formation in plant pathogenic bacteria. The report provides significant new information about the genetic

  8. Comparison of gene activation by two TAL effectors from Xanthomonas axonopodis pv. manihotis reveals candidate host susceptibility genes in cassava.

    Science.gov (United States)

    Cohn, Megan; Morbitzer, Robert; Lahaye, Thomas; Staskawicz, Brian J

    2016-08-01

    Xanthomonas axonopodis pv. manihotis (Xam) employs transcription activator-like (TAL) effectors to promote bacterial growth and symptom formation during infection of cassava. TAL effectors are secreted via the bacterial type III secretion system into plant cells, where they are directed to the nucleus, bind DNA in plant promoters and activate the expression of downstream genes. The DNA-binding activity of TAL effectors is carried out by a central domain which contains a series of repeat variable diresidues (RVDs) that dictate the sequence of bound nucleotides. TAL14Xam668 promotes virulence in Xam strain Xam668 and has been shown to activate multiple cassava genes. In this study, we used RNA sequencing to identify the full target repertoire of TAL14Xam668 in cassava, which includes over 50 genes. A subset of highly up-regulated genes was tested for activation by TAL14CIO151 from Xam strain CIO151. Although TAL14CIO151 and TAL14Xam668 differ by only a single RVD, they display differential activation of gene targets. TAL14CIO151 complements the TAL14Xam668 mutant defect, implying that shared target genes are important for TAL14Xam668 -mediated disease susceptibility. Complementation with closely related TAL effectors is a novel approach to the narrowing down of biologically relevant susceptibility genes of TAL effectors with multiple targets. This study provides an example of how TAL effector target activation by two strains within a single species of Xanthomonas can be dramatically affected by a small change in RVD-nucleotide affinity at a single site, and reflects the parameters of RVD-nucleotide interaction determined using designer TAL effectors in transient systems.

  9. The monofunctional catalase KatE of Xanthomonas axonopodis pv. citri is required for full virulence in citrus plants.

    Directory of Open Access Journals (Sweden)

    María Laura Tondo

    Full Text Available BACKGROUND: Xanthomonas axonopodis pv. citri (Xac is an obligate aerobic phytopathogen constantly exposed to hydrogen peroxide produced by normal aerobic respiration and by the plant defense response during plant-pathogen interactions. Four putative catalase genes have been identified in silico in the Xac genome, designated as katE, catB, srpA (monofunctional catalases and katG (bifunctional catalase. METHODOLOGY/PRINCIPAL FINDINGS: Xac catalase activity was analyzed using native gel electrophoresis and semi-quantitative RT-PCR. We demonstrated that the catalase activity pattern was regulated in different growth stages displaying the highest levels during the stationary phase. KatE was the most active catalase in this phase of growth. At this stage cells were more resistant to hydrogen peroxide as was determined by the analysis of CFU after the exposition to different H(2O(2 concentrations. In addition, Xac exhibited an adaptive response to hydrogen peroxide, displaying higher levels of catalase activity and H(2O(2 resistance after treatment with sub-lethal concentrations of the oxidant. In the plant-like medium XVM2 the expression of KatE was strongly induced and in this medium Xac was more resistant to H(2O(2. A XackatE mutant strain was constructed by insertional mutagenesis. We observed that catalase induction in stationary phase was lost meanwhile the adaptive response to peroxide was maintained in this mutant. Finally, the XackatE strain was assayed in planta during host plant interaction rendering a less aggressive phenotype with a minor canker formation. CONCLUSIONS: Our results confirmed that in contrast to other Xanthomonas species, Xac catalase-specific activity is induced during the stationary phase of growth in parallel with the bacterial resistance to peroxide challenge. Moreover, Xac catalases expression pattern is modified in response to any stimuli associated with the plant or the microenvironment it provides. The catalase Kat

  10. Comparison of PCR,DIA and Pathogenicity Assay for Detection of Xanthomonas axonopodis pv.citri,the Causal Agent of Citrus Bacterial Canker Disease

    Institute of Scientific and Technical Information of China (English)

    WANG Zhong-kang; SUN Xian-yun; YIN You-ping; ZHOU Chang-yong; XIA Yu-xian

    2004-01-01

    Polymerase chain reaction (PCR) approach based on newly designed primers, JYF5/JYR5, was applied for specific detection of Xanthomonas axonopodis pv.citri(Xac). The efficiency and reliability of PCR method were compared with dot immunobinding assay (DIA) and classical pathogenicity test techniques for detecting suspensions of pure cells of Xac and soaking sap of citrus tissues. Detection sensitivity of PCR was about 4.5 cells or 1.56 pg target DNA per reaction which was higher than that of DIA (ca. 450 cells per dot).These three techniques (PCR assay, DIA and Pathogenecity test) could always detect Xac from symptomatic citrus samples. Different performances were obtained from citrus materials without symptoms, and the positive detection frequency was PCR, DIA and pathogenicity test.

  11. Xanthomonas axonopodis pv. citri YaeQ structure reveals new compact protein fold built around a variation of the PD-(D/E)XK nuclease motif

    Energy Technology Data Exchange (ETDEWEB)

    Guzzo, Cristiane Rodrigues; Farah, Chuck Shaker [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Quimica. Dept. de Bioquimica; Nagem, Ronaldo Alves Pinto [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Inst. de Ciencias Biologicas. Dept. de Bioquimica e Imunologia; Barbosa, Joao Alexandre Ribeiro Goncalves [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil). Centro de Biologia Molecular Estrutural

    2008-11-15

    The YaeQ family of proteins derives from close to two hundred species of Gram-negative bacteria. Despite their widespread distribution, their molecular and physiological functions are unknown. We used X-ray crystallography and multi-wavelength anomalous dispersion to determine the high resolution structure of the YaeQ protein (XAC2398) from the phytopathogen Xanthomonas axonopodis pv. citri. The novel structure revealed that YaeQ pertains to the PD-(D/E)XK superfamily of metal-dependent endonucleases. The phylogenetic distribution of YaeQ proteins and a detailed comparison of the YaeQ structure with that of other PD-(D/E)XK family members point to specific testable hypotheses regarding YaeQ function. (author)

  12. The filamentous phage XacF1 causes loss of virulence in Xanthomonas axonopodis pv. citri, the causative agent of citrus canker disease

    Directory of Open Access Journals (Sweden)

    Abdelmonim Ali Ahmad

    2014-07-01

    Full Text Available In this study, filamentous phage XacF1, which can infect Xanthomonas axonopodis pv. citri (Xac strains, was isolated and characterized. Electron microscopy showed that XacF1 is a member of the family Inoviridae and is about 1000 nm long and 16 nm in width. The genome of XacF1 is 7325 nucleotides in size, containing 13 predicted open reading frames (ORFs, some of which showed significant homology to Ff-like phage proteins such as ORF1 (pII, ORF2 (pV, ORF6 (pIII, and ORF8 (pVI. XacF1 showed a relatively wide host range, infecting seven out of 11 strains tested in this study. Frequently, XacF1 was found to be integrated into the genome of Xac strains. This integration occurred at the host dif site (attB and was mediated by the host XerC/D recombination system. The attP sequence was identical to that of Xanthomonas phage Cf1c. Interestingly, infection by XacF1 phage caused several physiological changes to the bacterial host cells, including lower levels of extracellular polysaccharide production, reduced motility, slower growth rate, and a dramatic reduction in virulence. In particular, the reduction in virulence suggested possible utilization of XacF1 as a biological control agent against citrus canker disease.

  13. Detection of Xanthomonas axonopodis pv.dieffenbachiae in Authurium andreanum by Immunomagnetic Separation-PCR%利用免疫磁性分离-PCR检测安祖花细菌性枯萎病病原菌

    Institute of Scientific and Technical Information of China (English)

    王钊; 储丽红; 赵凯; 彭佳佳; 明军; 袁素霞; 刘春

    2013-01-01

    根据地毯草黄单胞菌花叶万年青致病变种(Xanthomonas axonopodis pv.dieffenbachiae)的RAPD序列设计特异性引物,并对羧基化磁珠的结合性能进行检验,从而建立和优化了免疫磁性分离-PCR体系,对安祖花细菌性枯萎病进行早期检测.结果表明:1 mg磁珠对多克隆抗体最大吸附值为0.268mg,进行免疫磁性捕获时免疫磁珠的最佳浓度是0.566 ~ 0.741 mg·mL-1.免疫磁性分离-PCR可以减少PCR反应中的抑制物质,对X.axonopodis pv.dieffenbachiae的检测灵敏度可以达到10 ~ 100 cfu· mL-1,比常规PCR检测灵敏至少100倍.%According to the RAPD ofXanthomonas axonopodis pv.dieffenbachiae,specific primers were designed,and binding ability of carboxyl magnetic beads were tested.The system of optimization of immunomagnetic separation-PCR (IMS-PCR) protocol for detecting the Bacterial Blight of Anthurium were establisted.The results showed that the saturate absorption of 1 mg carboxyl magnetic beads to the polyclonal antibodys is 0.268 mg.The optimal concentration of immunomagnetic beads (IMB) is 0.566-0.741 mg · mL-1 when X.axonopodis pv.dieffenbachiae is captured.The detection sensitivity for X.axonopodis pv.dieffenbachiae,by IMS-PCR which can reduce the inhibitory substances in reaction,is 10-100cfu· mL-1.It is 100 times more sensitive than ordinary PCR at least.

  14. A plant natriuretic peptide-like molecule of the pathogen Xanthomonas axonopodis pv. citri causes rapid changes in the proteome of its citrus host

    KAUST Repository

    Garavaglia, Betiana S

    2010-03-21

    Background: Plant natriuretic peptides (PNPs) belong to a novel class of peptidic signaling molecules that share some structural similarity to the N-terminal domain of expansins and affect physiological processes such as water and ion homeostasis at nano-molar concentrations. The citrus pathogen Xanthomonas axonopodis pv. citri possesses a PNP-like peptide (XacPNP) uniquely present in this bacteria. Previously we observed that the expression of XacPNP is induced upon infection and that lesions produced in leaves infected with a XacPNP deletion mutant were more necrotic and lead to earlier bacterial cell death, suggesting that the plant-like bacterial PNP enables the plant pathogen to modify host responses in order to create conditions favorable to its own survival.Results: Here we measured chlorophyll fluorescence parameters and water potential of citrus leaves infiltrated with recombinant purified XacPNP and demonstrate that the peptide improves the physiological conditions of the tissue. Importantly, the proteomic analysis revealed that these responses are mirrored by rapid changes in the host proteome that include the up-regulation of Rubisco activase, ATP synthase CF1 ? subunit, maturase K, and ?- and ?-tubulin.Conclusions: We demonstrate that XacPNP induces changes in host photosynthesis at the level of protein expression and in photosynthetic efficiency in particular. Our findings suggest that the biotrophic pathogen can use the plant-like hormone to modulate the host cellular environment and in particular host metabolism and that such modulations weaken host defence. 2010 Garavaglia et al; licensee BioMed Central Ltd.

  15. A plant natriuretic peptide-like molecule of the pathogen Xanthomonas axonopodis pv. citri causes rapid changes in the proteome of its citrus host

    Directory of Open Access Journals (Sweden)

    Ottado Jorgelina

    2010-03-01

    Full Text Available Abstract Background Plant natriuretic peptides (PNPs belong to a novel class of peptidic signaling molecules that share some structural similarity to the N-terminal domain of expansins and affect physiological processes such as water and ion homeostasis at nano-molar concentrations. The citrus pathogen Xanthomonas axonopodis pv. citri possesses a PNP-like peptide (XacPNP uniquely present in this bacteria. Previously we observed that the expression of XacPNP is induced upon infection and that lesions produced in leaves infected with a XacPNP deletion mutant were more necrotic and lead to earlier bacterial cell death, suggesting that the plant-like bacterial PNP enables the plant pathogen to modify host responses in order to create conditions favorable to its own survival. Results Here we measured chlorophyll fluorescence parameters and water potential of citrus leaves infiltrated with recombinant purified XacPNP and demonstrate that the peptide improves the physiological conditions of the tissue. Importantly, the proteomic analysis revealed that these responses are mirrored by rapid changes in the host proteome that include the up-regulation of Rubisco activase, ATP synthase CF1 α subunit, maturase K, and α- and β-tubulin. Conclusions We demonstrate that XacPNP induces changes in host photosynthesis at the level of protein expression and in photosynthetic efficiency in particular. Our findings suggest that the biotrophic pathogen can use the plant-like hormone to modulate the host cellular environment and in particular host metabolism and that such modulations weaken host defence.

  16. Development and validation of a Xanthomonas axonopodis pv. citri DNA microarray platform (XACarray generated from the shotgun libraries previously used in the sequencing of this bacterial genome

    Directory of Open Access Journals (Sweden)

    Zaini Paulo A

    2010-05-01

    Full Text Available Abstract Background From shotgun libraries used for the genomic sequencing of the phytopathogenic bacterium Xanthomonas axonopodis pv. citri (XAC, clones that were representative of the largest possible number of coding sequences (CDSs were selected to create a DNA microarray platform on glass slides (XACarray. The creation of the XACarray allowed for the establishment of a tool that is capable of providing data for the analysis of global genome expression in this organism. Findings The inserts from the selected clones were amplified by PCR with the universal oligonucleotide primers M13R and M13F. The obtained products were purified and fixed in duplicate on glass slides specific for use in DNA microarrays. The number of spots on the microarray totaled 6,144 and included 768 positive controls and 624 negative controls per slide. Validation of the platform was performed through hybridization of total DNA probes from XAC labeled with different fluorophores, Cy3 and Cy5. In this validation assay, 86% of all PCR products fixed on the glass slides were confirmed to present a hybridization signal greater than twice the standard deviation of the deviation of the global median signal-to-noise ration. Conclusions Our validation of the XACArray platform using DNA-DNA hybridization revealed that it can be used to evaluate the expression of 2,365 individual CDSs from all major functional categories, which corresponds to 52.7% of the annotated CDSs of the XAC genome. As a proof of concept, we used this platform in a previously work to verify the absence of genomic regions that could not be detected by sequencing in related strains of Xanthomonas.

  17. Regular LAMP and fast LAMP for the detection of Xanthomonas axonopodis pv.citri%柑橘溃疡病菌的普通LAMP及快速LAMP检测方法的建立

    Institute of Scientific and Technical Information of China (English)

    张仑; 殷幼平; 吴瑜佳; 王中康

    2013-01-01

    This study is aimed to establish the regular LAMP and fast LAMP for the detection of Xanthomonas axonopodis pv.citri and make it useful for the grassroots quarantine departments.A specific region of the genome of X.axonopodis pv.citri was used for the design of regular LAMP and fast LAMP primers; the regular LAMP and fast LAMP detection system were established by optimization of reaction conditions; the specificity of the system was verified using genomic DNA of several reference strains and healthy citrus leaves by using a series of gradient dilution of DNA solution of X.axonopodis pv.citri and bacterial suspension.Bacterial suspension and DNA sensitivity of regular LAMP system reached 2.25 × 104 cfu and 2.03× 10-1 ng,respectively,while those of fast LAMP system reached 2.25 cfu and 2.03× 10-5 ng,respectively.In the specificity test,both regular LAMP and fast LAMP system showed high and identical specificity.The total time for the fast LAMP reaction was within 30 minutes,only half of that for the regular LAMP,greatly improving the efficiency of the analysis.The fast LAMP system was ten thousand times as sensitive as the regular LAMP system.Regular LAMP and fast LAMP for the detection of X.axonopodis pv.citri was successfully established.Regular LAMP and fast LAMP system provide a new,fast and easy way for the detection of X.axonopodis pv.citri.%建立柑橘溃疡病菌的普通LAMP和快速LAMP检测方法,使其能应用于基层检验检疫部门对病害的快速检测.利用柑橘溃疡病菌基因组特有的保守区域设计LAMP引物,通过优化反应条件,建立柑橘溃疡病菌的普通LAMP检测体系;在普通LAMP引物的基础上设计一对环引物,建立柑橘溃疡病菌的快速LAMP检测体系,并以多种参比菌DNA以及健康柑橘叶片基因组DNA为模板对普通LAMP和快速LAMP检测体系的特异性进行了验证,利用柑橘溃疡病菌菌液和DNA溶液梯度稀释液对普通LAMP和快速LAMP检测体系的灵敏度进

  18. Caracterización de la respuesta morfológica de variedades susceptibles y resistentes de yuca (Manihot esculenta Crantz a la bacteriosis vascular causada por Xanthomonas axonopodis pv. manihotis

    Directory of Open Access Journals (Sweden)

    Tamara Sandino

    2015-06-01

    Full Text Available Xanthomonas axonopodis pv. manihotis es una de las principales limitaciones del cultivo de yuca. En esta investigación, mediante microscopía óptica, se realizó un análisis comparativo de los cambios morfológicos e histoquímicos en tallos de una variedad de yuca susceptible (TMS60444 y una resistente (CM6438-14, 7 y 14 días después de ser inoculadas con la cepa patogénica CIO151. Se pudo detectar que la variedad resistente genera barreras de calosa en las paredes celulares del parénquima cortical y del floema, manteniendo funcional este tejido. En tanto que los tejidos vasculares de la variedad susceptible colapsan, el floema por obstrucción total con tapones de calosa y por formación de compuestos fenólicos, y el xilema por formación de tílides y/o acumulación de compuestos fenólicos, sin poder frenar el avance sistémico de la enfermedad.

  19. Microwave-based Method for Genomic DNA Extraction and Rapid Detection Method from Xanthomonas axonopodis pv.citri%柑桔溃疡病菌基因组DNA的微波法抽提及快速检测

    Institute of Scientific and Technical Information of China (English)

    姚廷山; 周常勇; 胡军华; 冉春; 李鸿筠; 刘浩强; 肖田

    2012-01-01

    利用微波热震惊提取固体表面柑桔溃疡病基因组DNA并加以优化,所得到的基因组DNA可作为PCR反应的模板进行16SrDNA基因有效扩增.与柑桔溃疡病基园组DNA其他抽提方法相比较,微波法更适用于该病的快速检测,具有快速、筒便、费用低廉等特点,且对设备的要求不高,用特异性引物XCF/XCR可实现柑桔溃疡病菌的快速鉴定.%The optimized microwave extraction was conducted to attract the genome of citrus canker disease. The genome extraction method was fast,easy to handle with low cost The extracted DNA was suitable for PCR. The microwave-based method was suitable for fast identification compare to other methods. The method was effective, easy and fast, so it was recommended that the extraction method was applied for the detection of Xanthomonas oxonopodit pv. citri using primers XCF/XCR.

  20. Development of RLK-Derived Molecular Markers Associating with the Resistance to Citrus Canker [Xanthomonas axonopodis pv. Citri (Xac)] Disease%开发与柑桔抗溃疡病基因连锁的由RLK-RGC衍生的分子标记

    Institute of Scientific and Technical Information of China (English)

    向旭; 郑启发; 黄舒; 陈存贤; Frederick G. Gmitter Jr.; 邓占鳌

    2005-01-01

    本文是在先期研究工作的基础上,利用从柑桔与枳属间杂种的基因组DNA所获得的类受体激酶(RLK)的候选抗病基因序列,重新设计引物,对柑桔抗溃疡病材料和感病材料开展以PCR扩增为基础的对比分析,其中一对引物‘19h16/DdeI'的扩增产物经限制性内切酶DdeI酶切,揭示了抗性材料(Ichang Papeda,Meiwa kumquat,Maruhi kumquat and Nagami kumquat)和感病材料(Flying Dragon,Valencia orange and Palestine sweetlime)之间的多态性差异,同时,在C.Ichangensis的自交F1代和Palestine sweetlime× Ichang Papeda的杂交F1代群体中也见明显的多态性差异;对这些F1代个体进行溃疡病病原[Xanthomonas axonopodis pv.Citri(Xac)]接种作抗病性表型鉴定,结果表明,该分子标记‘19h16/DdeI'与柑桔溃疡病抗性密切相关;经纯化测序的结果进一步证明,抗性材料PCR扩增产物具有完全一致的序列和DdeI酶切位点,但感病材料缺少这一DdeI酶切位点;染色体步行(primerwalking)在BAC文库的对应单克隆中获得了一个完整的抗病基因序列,与以前获得的2个抗病基因序列‘17o6RLKP'和‘26m19RLKP'相比,‘19h16RLKP'也具有Xa21抗病基因蛋白的所有特征,包括含有一个信号肽、同样数目的亮氨酸重复序列、跨膜域和激酶域等.基于该序列的开放读码框,发展了特异性更强可靠性更高的另一分子标记,在今后的研究工作中具有较大的应用潜力.%By utilizing the receptor-like kinase (RLK) RGC sequences previously obtained from the genomic DNA of an intergeneric Citrus and Poncirus hybrid, PCR amplification with one pair of new-designed primers was found to reveal polymorphism between the theoretical resistant species (Ichang Papeda, Meiwa kumquat,Maruhi kumquat and Nagami kumquat) and susceptible species (Flying Dragon, Valencia orange and Palestine sweet lime ) and among the self-crossing population of C. Ichangensis and F1 population of Palestine sweet lime

  1. Introduction of the Escherichia coli gdhA gene into Rhizobium phaseoli: effect on nitrogen fixation.

    Science.gov (United States)

    Bravo, A; Becerril, B; Mora, J

    1988-01-01

    Rhizobium phaseoli lacks glutamate dehydrogenase (GDH) and assimilates ammonium by the glutamine synthetase-glutamate synthase pathway. A strain of R. phaseoli harboring the Escherichia coli GDH structural gene (gdhA) was constructed. GDH activity was expressed in R. phaseoli in the free-living state and in symbiosis. Nodules with bacteroids that expressed GDH activity had severe impairment of nitrogen fixation. Also, R. phaseoli cells that lost GDH activity and assimilated ammonium by the glutamine synthetase-glutamate synthase pathway preferentially nodulated Phaseolus vulgaris. PMID:2892830

  2. Chemical Composition and Antibacterial Activity of Essential Oils of Tagetes minuta (Asteraceae) against Selected Plant Pathogenic Bacteria

    OpenAIRE

    Martin Muthee Gakuubi; Wagacha, John M.; Saifuddin F. Dossaji; Wycliffe Wanzala

    2016-01-01

    The objective of this study was to determine the chemical composition and antibacterial activity of essential oils (EOs) of Tagetes minuta against three phytopathogenic bacteria Pseudomonas savastanoi pv. phaseolicola, Xanthomonas axonopodis pv. phaseoli, and Xanthomonas axonopodis pv. manihotis. The essential oils were extracted using steam distillation method in a modified Clevenger-type apparatus while antibacterial activity of the EOs was evaluated by disc diffusion method. Gas chromatogr...

  3. A plant natriuretic peptide-like gene in the bacterial pathogen Xanthomonas axonopodis may induce hyper-hydration in the plant host: a hypothesis of molecular mimicry

    Directory of Open Access Journals (Sweden)

    Sayed Muhammed

    2004-03-01

    Full Text Available Abstract Background Plant natriuretic peptides (PNPs are systemically mobile molecules that regulate homeostasis at nanomolar concentrations. PNPs are up-regulated under conditions of osmotic stress and PNP-dependent processes include changes in ion transport and increases of H2O uptake into protoplasts and whole tissue. Presentation of the hypothesis The bacterial citrus pathogen Xanthomonas axonopodis pv. Citri str. 306 contains a gene encoding a PNP-like protein. We hypothesise that this bacterial protein can alter plant cell homeostasis and thus is likely to represent an example of molecular mimicry that enables the pathogen to manipulate plant responses in order to bring about conditions favourable to the pathogen such as the induced plant tissue hyper-hydration seen in the wet edged lesions associated with Xanthomonas axonopodis infection. Testing the hypothesis We found a Xanthomonas axonopodis PNP-like protein that shares significant sequence similarity and identical domain organisation with PNPs. We also observed a significant excess of conserved residues between the two proteins within the domain previously identified as being sufficient to induce biological activity. Structural modelling predicts identical six stranded double-psi β barrel folds for both proteins thus supporting the hypothesis of similar modes of action. No significant similarity between the Xanthomonas axonopodis protein and other bacterial proteins from GenBank was found. Sequence similarity of the Xanthomonas axonopodis PNP-like protein with the Arabidopsis thaliana PNP (AtPNP-A, shared domain organisation and incongruent phylogeny suggest that the PNP-gene may have been acquired by the bacteria in an ancient lateral gene transfer event. Finally, activity of a recombinant Xanthomonas axonopodis protein in plant tissue and changes in symptoms induced by a Xanthomonas axonopodis mutant with a knocked-out PNP-like gene will be experimental proof of molecular mimicry

  4. Infestation of Caliothrips phaseoli (Thysanoptera: Thripidae) on Bean Cultivars Grown in the Winter, Rainy, and Dry Seasons in Brazil.

    Science.gov (United States)

    Boiça Júnior, Arlindo Leal; Costa, Eduardo Neves; De Souza, Bruno Henrique Sardinha; Da Silva, Anderson Gonçalves; Chiorato, Alisson Fernando

    2015-08-01

    The present study aimed to identify common bean (Phaseolus vulgaris L.) cultivars less susceptible to Caliothrips phaseoli (Hood) in different growing seasons, to evaluate whether climatic conditions influence plant resistance to C. phaseoli infestation, and to investigate the preferred plant part for insect feeding. Eighteen common bean cultivars were evaluated in the winter season, and 19 cultivars were assessed in the rainy and dry seasons, under field conditions in the municipality of Jaboticabal, state of São Paulo, Brazil. Infestation of C. phaseoli nymphs in the upper and lower parts of the beans plants was recorded at weekly intervals from 25 days after plant emergence (DAE) to 60 DAE. In the winter season, the cultivars 'IAC Galante,' 'IAC Centauro,' 'IAC Carioca Eté,' and 'IAC Formoso' had significantly lower number of thrips than the cultivar 'IAC Diplomata.' In the rainy season, the cultivars 'IAC Harmonia' and 'IPR Siriri' had the lowest thrips infestation, differing from the cultivars 'BRS Pontal' and 'IAC Una.' The bean cultivars were equally susceptible to C. phaseoli in the dry season. The results suggest that C. phaseoli nymphs prefer to infest leaves of the lower part of bean plants, like most generalist herbivorous insects. In the winter and dry seasons, the highest thrips infestation was observed at 60 DAE, while in the rainy season, it was recorded from 32 to 46 DAE. Overall, C. phaseoli infestation on bean cultivars was not influenced by either temperature, relative humidity, or rainfall.

  5. A DNA-Based Procedure for In Planta Detection of Fusarium oxysporum f. sp. phaseoli.

    Science.gov (United States)

    Alves-Santos, Fernando M; Ramos, Brisa; García-Sánchez, M Asunción; Eslava, Arturo P; Díaz-Mínguez, José María

    2002-03-01

    ABSTRACT We have characterized strains of Fusarium oxysporum from common bean fields in Spain that were nonpathogenic on common bean, as well as F. oxysporum strains (F. oxysporum f. sp. phaseoli) pathogenic to common bean by random amplified polymorphic DNA (RAPD) analysis. We identified a RAPD marker (RAPD 4.12) specific for the highly virulent pathogenic strains of the seven races of F. oxysporum f. sp. phaseoli. Sequence analysis of RAPD 4.12 allowed the design of oligonucleotides that amplify a 609-bp sequence characterized amplified region (SCAR) marker (SCAR-B310A280). Under controlled environmental and greenhouse conditions, detection of the pathogen by polymerase chain reaction was 100% successful in root samples of infected but still symptomless plants and in stem samples of plants with disease severity of >/=4 in the Centro Internacional de Agricultura Tropical (CIAT; Cali, Colombia) scale. The diagnostic procedure can be completed in 5 h and allows the detection of all known races of the pathogen in plant samples at early stages of the disease with no visible symptoms.

  6. Interacción de Tsukamurella paurometabola C-924 con Rhizobium leguminosarum biovar phaseoli CFH en el cultivo de frijol

    Directory of Open Access Journals (Sweden)

    Marieta Marín Bruzos

    2013-01-01

    Full Text Available En el estudio se evaluaron, mediante análisis de los parámetros fenológicos de las plantas, la interacción de Tsukamurella paurometabola C-924 con Rhizobium leguminosarum biovar phaseoli CFH en el cultivo de frijol. Se emplearon cuatro tratamientos: plantas sin inocular (control, inoculadas con T. paurometabola C-924, inoculadas con R. leguminosarum biovar phaseoli CFH e inoculadas con ambas cepas. Se observaron diferencias significativas (P < 0.01 en los porcentajes de germinación de las plantas tratadas con microorganismos de forma independiente o conjunta con respecto al control sin inocular. Se determinó que la inoculación de T. paurometabola C-924 afectó el proceso de nodulación de R. leguminosarum biovar phaseoli CFH. Sin embargo, esto no incidió de manera significativa en la altura de las plantas ni en el diámetro del tallo, ya que no se encontraron diferencias entre los tratamientos para estos parámetros. Para el número de hojas, los mejores resultados se obtuvieron con la aplicación de T. paurometabola C-924. Se concluyó que la interacción de T. paurometabola C-924 con R. leguminosarum biovar phaseoli CFH en el frijol estimuló significativamente la germinación de las semillas y el número de hojas de las plantas con respecto al control sin inocular. Aunque la aplicación de T. paurometabola C-924 no favoreció la nodulación de R. leguminosarum biovar phaseoli CFH, esto no afectó las características fenológicas del cultivo.

  7. Reação de linhagens de feijoeiro ao fungo Fusarium oxysporum f. sp. phaseoli em condições controladas Reaction of common bean lines to Fusarium oxysporum f. sp. phaseoli in controlled conditions

    Directory of Open Access Journals (Sweden)

    Mônica Juliani Zavaglia Pereira

    2011-10-01

    Full Text Available Entre os patógenos que mais contribuem para a redução da produtividade do feijoeiro no Brasil está o Fusarium oxysporum f. sp. phaseoli. O emprego de cultivares resistentes é o controle mais eficaz para esse patógeno. Conduziu-se este trabalho, com o objetivo de avaliar linhagens de feijoeiro (Phaseolus vulgaris L. do banco de germoplasma da Universidade Federal de Lavras (UFLA, quanto a reação ao Fusarium oxysporum f. sp. phaseoli e, ao mesmo tempo, estimar os parâmetros genéticos e fenotípicos que possam auxiliar em futuros programas de melhoramento para esse caráter. Foram avaliadas 367 linhagens em dez experimentos. As testemunhas 'Carioca' (suscetível e 'Carioca MG' (resistente foram utilizadas em todos os experimentos. O delineamento utilizado foi inteiramente ao acaso, com cinco repetições e parcelas de uma planta por vaso. As inoculações foram realizadas segundo a metodologia de corte e imersão de raízes na suspensão de esporos do fungo e as avaliações realizadas aos 21 dias após a inoculação com base no índice de severidade da doença empregando-se notas de 1 (plantas sem sintomas a 9 (plantas mortas.Das linhagens do banco de germoplasma da Universidade Federal de Lavras (UFLA avaliadas, 36,5% foram resistentes ao Fusarium oxysporum f. sp. phaseoli. Entre as resistentes, a maioria foi linhagens obtidas antes de 1990. Das 18 linhagens dos experimentos de VCU, do período de 2005/06, apenas quatro foram suscetíveis. A estimativa da herdabilidade (h² foi elevada (h² = 87%, indicando que, a princípio, o caráter é de fácil seleção.Among the pathogens that most contribute for reducing the productivity of beans in Brazil is the Fusarium oxysporum f. sp. phaseoli. The use of resistant cultivars is the most effective control for this pathogen. The aim of this study was to evaluate germoplasm bean (Phaseolus vulgaris L. lines of the Federal University of Lavras (UFLA as the reaction to the Fusarium oxysporum f

  8. Autonomous cascaded PV system

    OpenAIRE

    2011-01-01

    This paper proposes multi-level PV system; three PV generators each coupled to a buck cell. Each PV-generator-buckconverter channel is controlled such that maximum power is captured independently under different irradiation and temperature levels. The system operation under normal/abnormal conditions is investigated by thoroughly mathematical and simulation work. Peer Reviewed

  9. Controle de Rhizoctonia solani e Fusarium oxysporum f.sp. phaseoli por biopreparados de isolados de Trichoderma spp.

    Directory of Open Access Journals (Sweden)

    Pedro Paulo Dias

    2013-12-01

    Full Text Available Os experimentos objetivaram avaliar em condições de casa de vegetação o biocontrole dos fitopatógenos Rhizoctonia solani (RS e Fusarium oxysporum f.sp. phaseoli (FOP em alface (Lactuca sativa L. cultivar Regina, e feijão-vagem (Phaseolus vulgaris L. cultivar Alessa, respectivamente, utilizando como agentes antagonistas, 10 isolados de Trichoderma spp. selecionados em testes in vitro. Foram feitos biopreparados à base de arroz previamente colonizado por isolados de Trichoderma spp. e posteriormente triturados. Para a realização dos testes, os biopreparados foram inoculados previamente na proporção de 10(9 conídios.mL-1, em substrato comercial para produção de mudas. Após sete dias, os patógenos foram introduzidos separadamente em duas concentrações distintas: R. solani na proporção de 144 mg de meio de arroz por kg de substrato e F. oxysporum f.sp. phaseoli inoculado na forma de suspensão contendo 4,75 x 10(6 conídios.mL-1. Avaliou-se a influência dos biopreparados na % de damping-off de pós-emergência em plantas de alface e a severidade de murcha em plantas de feijão-vagem. O biopreparado referente ao isolado T-03 foi o mais eficiente no controle de R. solani em plantas de alface cultivar Regina, por ter reduzido a incidência de damping-off de pós-emergência nessa cultura. Por outro lado, nenhum dos biopreparados apresentou efeito antagonista satisfatório à F. oxysporum f.sp. phaseoli em plantas de feijão-vagem.

  10. Isolation of Rhizobium phaseoli Tn5-induced mutants with altered expression of cytochrome terminal oxidases o and aa3.

    Science.gov (United States)

    Soberón, M; Membrillo-Hernández, J; Aguilar, G R; Sánchez, F

    1990-01-01

    Two Rhizobium phaseoli mutants affected in cytochrome expression were obtained by Tn5-mob mutagenesis of the wild-type strain (CE3). Mutant strain CFN031 expressed sevenfold less cytochrome o in culture, expressed cytochrome aa3 under microaerophilic culture conditions, in contrast to strain CE3, and was affected in its vegetative growth properties and proliferation inside plant host cells. Mutant CFN037 expressed cytochrome aa3 under microaerophilic culture conditions, while bacteroid development and nitrogen fixation occurred earlier than in strain CE3. Images FIG. 2 PMID:2155209

  11. Fire resistant PV shingle assembly

    Science.gov (United States)

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  12. Infestação de Bemisia tabaci biótipo B e Caliothrips phaseoli em genótipos de feijoeiro Infestation of Bemisia tabaci biotype B and Caliothrips phaseoli on bean genotypes

    Directory of Open Access Journals (Sweden)

    Flávio Gonçalves de Jesus

    2010-01-01

    Full Text Available Avaliou-se o comportamento de genótipos de feijoeiro sob a infestação de Bemisia tabaci (Genn. biótipo B e Caliothrips phaseoli (Hood em condições de campo, nas épocas de cultivo "de inverno", "das águas" e "da seca". Adotou-se o delineamento de blocos casualizados em esquema de parcelas sub-subdividida (19x3x6, com 19 genótipos (IAC Tybatã, IAC Una, FT Nobre, Pérola, Gen 96A98-15-3-32-1, Gen 96A45-3-51-52-1, IAC Alvorada, IAC Diplomata, Gen 96A3-P1-1-1, LP 98-122, LP 02-130, LP 01-38, LP 9979, BRS-Pontal, BRS-Requinte, BRS-Triunfo, BRS-Grafite, CV-48 e Z-28, três épocas de cultivos (inverno, águas e seca e seis períodos de avaliação. As avaliações foram realizadas semanalmente, contando-se o número de ovos e ninfas de B. tabaci e ninfas de C. phaseoli em dez folíolos por parcela. Os genótipos IAC Una, Pérola, Gen 96A45-3-51-52-1, Gen 96A98-15-32-1, FT Nobre, IAC Tybatã, IAC Alvorada, LP 02-130, LP 01-38, LP 98-122, IAC Diplomata e Gen 96A3P1-1-1 foram menos ovipositados por B. tabaci no cultivo "das águas". Os genótipos Pérola, Gen 96A45-3-51-52-1, IAC Una, Gen 96A98-15-32-1, IAC Tybatã e FT Nobre foram menos infestados por C. phaseoli. A maior incidência de ninfas de mosca-branca ocorreu no fim de janeiro no cultivo "das águas" e início de maio no cultivo "da seca"; para tripés, foi em junho durante o cultivo "de inverno". A maior incidência da população de B. tabaci e C. phaseoli, ocorreu dos 46 aos 60 dias após a emergência das plantas.The response of bean genotypes to infestation of Bemisia tabaci (Genn. biotype B and Caliothrips phaseoli (Hood in field conditions on the winter, rainy and dry seasons was evaluated. The experiment was arranged in a randomized Sub-divided (19x3x6 blocks design with 19 genotypes (IAC Tybatã, IAC Una, FT Nobre, Pérola, Gen 96A98-15-3-32-1, Gen 96A45-3-51-52-1, IAC Alvorada, IAC Diplomata, Gen 96A3-P1-1-1, LP 98-122, LP 02-130, LP 01-38, LP 9979, BRS-Pontal, BRS

  13. PV power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the international seminar of the Ostbayerisches Technologie-Transfer-Institut e.V. (OTTI) at 11th June, 2012 in Munich (Federal Republic of Germany), the following lectures were held: (1) Technical due diligence (Dietmar Obst); (2) Certification / rating system for large PV plants (Robert Pfatischer); (3) O and M requirements (Lars Rulf); (4) IR photography for large scale systems (Bernhard Weinreich); (5) New market models for PV systems - direct marketing and sales of PV electricity (Martin Schneider); (6) Needs and benefits for plant certification for grid connection and operation (Christoph Luetke-Lengerich); (7) Lare volume module testing / Screening in the field and workshop (Semir Merzoug); (8) Dismantling costs of large scale PV plants (Siegfried Schimpf).

  14. Grid integrated distributed PV (GridPV).

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle

    2013-08-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functions are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in the OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function in the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  15. PV-WEB: internet-based PV information tool

    Energy Technology Data Exchange (ETDEWEB)

    Cowley, P.

    2003-07-01

    This report gives details of a project to create a web-based information system on photovoltaic (PV) systems for the British PV Association (PV-UK) for use by decision makers in government, the utilities, and the housing and construction sectors. The project, which aims to provide an easily accessible tool for UK companies, promote PV technology, increase competitiveness, and identify market opportunities, is described. The design of the web site and its implementation and the evolution are discussed, along with the maintenance of the site by PV-UK and the opportunities offered to PV-UK Members.

  16. PV investment in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Hueser, Pius [Nova Energy GmbH, (Switzerland)

    2007-06-15

    This presentation is mainly about how the PV market in Europe has been growing, and which elements are going to determine if this market succeed or failed not only in Europe but also in the rest of the world. In the first part of this presentation, it is mentioned how in 2005 the development of some PV technologies triggered the PV market growth without any marketing control. Then, there are explained the aspects that changed such situation out of control, therefore, it emerged the beginning of the consolidation of this market. There are briefly explained those factors that are going to determine if this market succeed or failed in the future. Finally, there are given examples of some the PV investments. [Spanish] Esta presentacion habla principalmente de la manera en como ha crecido el Mercado de sistemas fotovoltaicos en Europa, asi tambien se mencionan los elementos fundamentales que determinaran el exito o fracaso de este mercado, no solamente en Europa sino tambien en el resto del mundo, en un futuro. En la primera parte de esta presentacion, se describe como en el 2005, debido al desarrollo de algunas tecnologias fotovoltaicas se desencadeno el crecimiento desenfrenado del mercado fotovoltaico. Despues, se explican los aspectos que hicieron que dicho crecimiento tomara su curso, teniendo como resultado el inicio de un mercado mas consolidado. Se explican brevemente los factores que determinaran si este mercado encuentra el exito o el fracaso en un futuro. Finalmente, se dan ejemplos de algunas adquisiciones fotovoltaicas.

  17. A look into the invisible: ultraviolet-B sensitivity in an insect (Caliothrips phaseoli) revealed through a behavioural action spectrum.

    Science.gov (United States)

    Mazza, Carlos A; Izaguirre, Miriam M; Curiale, Javier; Ballaré, Carlos L

    2010-02-07

    Caliothrips phaseoli, a phytophagous insect, detects and responds to solar ultraviolet-B radiation (UV-B; lambda insects are sensitive. We constructed an action spectrum of thrips responses to light by studying their behavioural reactions to monochromatic irradiation under confinement conditions. Thrips were maximally sensitive to wavelengths between 290 and 330 nm; human-visible wavelengths (lambda >or= 400 nm) failed to elicit any response. All but six ommatidia of the thrips compound eye were highly fluorescent when exposed to UV-A of wavelengths longer than 330 nm. We hypothesized that the fluorescent compound acts as an internal filter, preventing radiation with lambda > 330 nm from reaching the photoreceptor cells. Calculations based on the putative filter transmittance and a visual pigment template of lambda(max) = 360 nm produced a sensitivity spectrum that was strikingly similar to the action spectrum of UV-induced behavioural response. These results suggest that specific UV-B vision in thrips is achieved by a standard UV-A photoreceptor and a sharp cut-off internal filter that blocks longer UV wavelengths in the majority of the ommatidia.

  18. Firefighter Safety for PV Systems

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Sera, Dezso; Spataru, Sergiu

    2015-01-01

    An important and highly discussed safety issue for photovoltaic (PV) systems is that as long as the PV panels are illuminated, a high voltage is present at the PV string terminals and cables between the string and inverters that is independent of the state of the inverter's dc disconnection switc...

  19. Testing for PV Reliability (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Bansal, S.

    2014-09-01

    The DOE SUNSHOT workshop is seeking input from the community about PV reliability and how the DOE might address gaps in understanding. This presentation describes the types of testing that are needed for PV reliability and introduces a discussion to identify gaps in our understanding of PV reliability testing.

  20. PV potential and potential PV rent in European regions

    DEFF Research Database (Denmark)

    Hansen, Anders Chr.; Thorn, Paul

    2013-01-01

    The paper provides a GIS based model for assessing the potentials of photovoltaic electricity in Europe by NUTS 2 regions. The location specific energy potential per PV-­‐panel area is estimated based on observations of solar irradiation, conversion efficiency, levelised costs and the social value...... of PV-­‐electricity. Combined with the potential density of PV-­‐panel area based on land cover and environental restrictions, the PV energy potential and the potential PV ressource rent is calculated. These calculations enbable the model to estimate the regional patterns at NUTS 2 level...

  1. PV water pumping: NEOS Corporation recent PV water pumping activities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, C.

    1995-11-01

    NEOS Corporation has been very active in PV-powered water pumping, particularly with respect to electric utilities. Most of the recent activity has been through the Photovoltaic Services Network (PSN). The PSN is an independent, not-for-profit organization comprised of all types of electric utilities: rural electric coops, public power districts, investor-owned utilities, and power marketing agencies. The PSN`s mission is to work pro-actively to promote utility involvement in PV through education and training. PV information is distributed by the PSN in three primary forms: (1) consultation with PSN technical service representatives: (2) literature generated by the PSN; and (3) literature published by other organizations. The PSN can also provide assistance to members in developing PV customer service programs. The PSN`s product support activities include consolidation of information on existing packaged PV systems and facilitation of the development of new PV product packages that meet utility-defined specifications for cost performance, and reliability. The PSN`s initial product support efforts will be focused on commercially available packaged PV systems for a variety of off-grid applications. In parallel with this effort, if no products exist that meet the PSN`s functional specifications, the PSN will initiate the second phase of product development support process by encouraging the development of new packaged systems. Through these services and product support activities, the PSN anticipates engaging all segments for the PV industry, thus providing benefits to PV systems suppliers as well as local PV service contractors.This paper describes field testing of pv power systems for water pumping.

  2. Effect of bean genotypes, insecticides, and natural products on the control of Bemisia tabaci (Gennadius biotype B (Hemiptera: Aleyrodidae and Caliothrips phaseoli (Hood (Thysanoptera: Thripidae = Efeito de genótipos de feijoeiro, inseticida e produtos naturais no controle Bemisia tabaci (Gennadius biotipo B (Hemiptera: Aleyrodidae e Caliothrips phaseoli (Hood (Thysanoptera: Thripidae

    Directory of Open Access Journals (Sweden)

    Júlio Cesar Janini

    2011-07-01

    Full Text Available Effect of bean genotypes, insecticides, and natural products on the control of Bemisia tabaci (Gennadius biotype B (Hemiptera: Aleyrodidae and Caliothrips phaseoli (Hood (Thysanoptera: Thripidae. The influence of bean genotypes associated with neem oil as insecticide was evaluated to control B. tabaci (Gennadius biotype B and C. phaseoli (Hood during the wet season sowing. The experimental design used was the randomized block arrangement in a 4x4x3 factorial scheme, represented by genotypes, neem oil and insecticides respectively, with three replications. The genotypes Carioca, IAC Harmonia, IAC Centauro and Pérola were used. The evaluations were done at 14 and 42 days after seedling emergence, bycounting B. tabaci biotype B eggs and nymphs and C. phaseoli nymphs in the genotypes leaf. Conclusion: The B. tabaci biotype B eggs and nymphs number were smaller in IAC Centauro and higher in IAC Harmonia. The tested genotypes were similarly infested by C. phaseoli. IAC Centauro and IAC Harmonia genotypes associated with neem oil (highlighting the full dose – 1% provided lower number of whitefly eggs and thrips nymphs. Neem oil at the full dose alsoreduced whitefly nymph number. In the tested genotypes the insecticide provided reduction in the number of whitefly eggs and nymphs as well in the thrips nymphs, with increase in therecommend dose. Avaliou-se a influência de genótipos de feijoeiro associado à aplicação de óleo de nim e inseticida no controle de B. tabaci (Gennadius biótipo B e C. phaseoli (Hood na época de semeadura “das águas”. O delineamento experimental utilizados foi o de blocos casualizados dispostos em um esquema fatorial 4 x 3 x 3, representado por variedades, óleo de nim e inseticidas, respectivamente, com três repetições. Utilizaram-se os genótipos Carioca, IAC Harmonia, IAC Centauro e Pérola. As avaliações foram realizadas dos 14 aos 42 dias após a emergência das plantas, contando-se o número de ovos e

  3. Advances in PV Inverters

    DEFF Research Database (Denmark)

    Anthon, Alexander

    Renewable energies have experienced a significant growth and importance in the last two decades, of which energy from photovoltaic plants are a major contributor. Since solar cells have low efficiencies themselves, however, the necessity of high efficiency power converters at low cost...... and preferably low complexity leads to new research demands. This is especially true in the field of low cost residential PV inverters where efficiencies are used as major selling arguments. Traditional converter topologies equipped with conventional Silicon based semiconductors to date reach their limitations...

  4. Sensorless PV Array Diagnostic Method for Residential PV Systems

    DEFF Research Database (Denmark)

    Sera, Dezso; Spataru, Sergiu; Mathe, Laszlo

    2011-01-01

    This work proposes a temperature and irradiance sensorless diagnostic method suitable for small residential PV installations, focusing on detection of partial shadows. The method works by detection of failures in crystalline silicone PV arrays by concomitant monitoring of some of their key parame...

  5. Interband cascade (IC) photovoltaic (PV) architecture for PV devices

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui Q.; Tian, Zhaobing; Mishima, Tetsuya D.; Santos, Michael B.; Johnson, Matthew B.; Klem, John F.

    2015-10-20

    A photovoltaic (PV) device, comprising a PV interband cascade (IC) stage, wherein the IC PV stage comprises an absorption region with a band gap, the absorption region configured to absorb photons, an intraband transport region configured to act as a hole barrier, and an interband tunneling region configured to act as an electron barrier. An IC PV architecture for a photovoltaic device, the IC PV architecture comprising an absorption region, an intraband transport region coupled to the absorption region, and an interband tunneling region coupled to the intraband transport region and to the adjacent absorption region, wherein the absorption region, the intraband transport region, and the interband tunneling region are positioned such that electrons will flow from the absorption region to the intraband transport region to the interband tunneling region.

  6. PV in a sports arena; PV im Hexenkessel

    Energy Technology Data Exchange (ETDEWEB)

    Hoeche, B.

    2008-05-19

    The German soccer club Werder Bremen is reconstructing its stadium. Apart from higher spectator comfort and a better atmosphere, there will also be PV systems on the roof and external walls of the arena. (orig.)

  7. Speedometers for PV generators; Drehzahlmesser fuer PV-Generatoren

    Energy Technology Data Exchange (ETDEWEB)

    Fritze, Peter; Weinreich, Bernhard [Solarschmiede GmbH, Muenchen (Germany). Engineering-Abt.

    2011-05-31

    To measure the generator power of an installed PV system, it is not enough to look into the specifications of hte module producers. Fast and independent data can be provided by characteristic curve meters.

  8. PSCAD Modules Representing PV Generator

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2013-08-01

    Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

  9. Adaptabilidade, estabilidade e resistência a patógenos em genótipos de feijoeiro

    Directory of Open Access Journals (Sweden)

    Cleber Vinicius Giaretta Azevedo

    2015-10-01

    Full Text Available Resumo:O objetivo deste trabalho foi avaliar a resistência de genótipos de feijoeiro aos principais patógenos da cultura, bem como a adaptabilidade e a estabilidade de produção de grãos desses genótipos. Avaliaram-se 26 genótipos de feijoeiro quanto à resistência a Colletotrichum lindemuthianum, Fusarium oxysporum f. sp. phaseolie Xanthomonas axonopodis pv. phaseoli, por meio de inoculação, em laboratório, e em 19 ensaios de valor de cultivo e uso (VCU, em diferentes locais do Estado de São Paulo, nas safras das "águas", "seca" e "inverno", durante os anos agrícolas 2011, 2012 e 2013. Dezoito genótipos foram considerados resistentes: sete deles a C. lindemuthianum, sete a F. oxysporumf. sp. phaseolie quatro a X. axonopodispv. phaseoli. A reação de resistência aos patógenos está associada à estabilidade dos genótipos. Por meio das análises GGE biplot, foi possível identificar genótipos com adaptabilidade e estabilidade superiores às das testemunhas, nos dois grupos de tegumento avaliados, em todas as épocas de semeadura.

  10. Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Ainsworth, Nathan; Gotseff, Peter; Baker, Kyri

    2016-05-05

    A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed study could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.

  11. Low concentrator PV optics optimization

    Science.gov (United States)

    Sharp, Leonard; Chang, Ben

    2008-08-01

    Purpose: Cost reduction is a major focus of the solar industry. Thin film technologies and concentration systems are viable ways to reducing cost, with unique strengths and weakness for both. Most of the concentrating PV work focuses on high concentration systems for reducing energy cost. Meanwhile, many believe that low concentrators provide significant cost reduction potential while addressing the mainstream PV market with a product that acts as a flat panel replacement. This paper analyzes the relative benefit of asymmetric vs. symmetric optics for low-concentrators in light of specific PV applications. Approach: Symmetric and asymmetric concentrating PV module performance is evaluated using computer simulation to determine potential value across various geographic locations and applications. The selected optic design is modeled against standard cSi flat panels and thin film to determine application fit, system level energy density and economic value. Results: While symmetric designs may seem ideal, asymmetric designs have an advantage in energy density. Both designs are assessed for aperture, optimum concentration ratio, and ideal system array configuration. Analysis of performance across climate specific effects (diffuse, direct and circumsolar) and location specific effects (sunpath) are also presented. The energy density and energy production of low concentrators provide a compelling value proposition. More significantly, the choice of optics for a low concentrating design can affect real world performance. With the goal of maximizing energy density and return on investment, this paper presents the advantages of asymmetric optic concentration and illustrates the value of this design within specific PV applications.

  12. Flexible packaging for PV modules

    Science.gov (United States)

    Dhere, Neelkanth G.

    2008-08-01

    Economic, flexible packages that provide needed level of protection to organic and some other PV cells over >25-years have not yet been developed. However, flexible packaging is essential in niche large-scale applications. Typical configuration used in flexible photovoltaic (PV) module packaging is transparent frontsheet/encapsulant/PV cells/flexible substrate. Besides flexibility of various components, the solder bonds should also be flexible and resistant to fatigue due to cyclic loading. Flexible front sheets should provide optical transparency, mechanical protection, scratch resistance, dielectric isolation, water resistance, UV stability and adhesion to encapsulant. Examples are Tefzel, Tedlar and Silicone. Dirt can get embedded in soft layers such as silicone and obscure light. Water vapor transmittance rate (WVTR) of polymer films used in the food packaging industry as moisture barriers are ~0.05 g/(m2.day) under ambient conditions. In comparison, light emitting diodes employ packaging components that have WVTR of ~10-6 g/(m2.day). WVTR of polymer sheets can be improved by coating them with dense inorganic/organic multilayers. Ethylene vinyl acetate, an amorphous copolymer used predominantly by the PV industry has very high O2 and H2O diffusivity. Quaternary carbon chains (such as acetate) in a polymer lead to cleavage and loss of adhesional strength at relatively low exposures. Reactivity of PV module components increases in presence of O2 and H2O. Adhesional strength degrades due to the breakdown of structure of polymer by reactive, free radicals formed by high-energy radiation. Free radical formation in polymers is reduced when the aromatic rings are attached at regular intervals. This paper will review flexible packaging for PV modules.

  13. Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, L.; Gostein, M.; Emery, K.

    2012-09-01

    As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

  14. Van lPv4 naar lPv6

    NARCIS (Netherlands)

    Luiijf, H.A.M.

    2008-01-01

    Organisaties die het Internet Protocol(IP) gebruiken voor beveiligingsdoeleinden en aanbieders van beveiligingsproducten ontkomen de komende jaren niet aan de overgang naar het nieuwe protocol lPv6. Enerzijds is het gelukkig dat die overgang niet op één dag wereldwijd zal plaatsvinden, er is geen 'I

  15. Solar PV. Innovators talking; Zon PV. Innovators aan het woord

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-02-15

    Qualitative studies have been conducted of the results of completed projects focused on energy innovation, spread over the seven themes of the top sector Energy: Energy saving in industry, Energy conservation in the built environment, Gas, Bio-energy, Smart grids, Offshore Wind, Solar PV. This provides insight into the follow-up activities and lessons of some EOS (Energy Research Subsidy) completed projects with the aim to inspire, connect and strengthen the TKIs (Topconsortia for Knowledge and Innovation) and individual companies and researchers working on energy innovation. This report concerns the research on solar PV [Dutch] Er is een kwalitatief onderzoek uitgevoerd naar de resultaten van afgeronde projecten gericht op energie-innovatie, verdeeld over de zeven thema's van de topsector Energie: Energiebesparing in de industrie; Energiebesparing in de gebouwde omgeving; Gas; Bio-energie; Smart grids; Wind op zee; Zon-pv. Daarmee wordt inzicht gegeven in de vervolgactiviteiten en lessen van een aantal afgesloten EOS-projecten (Energie Onderzoek Subsidie) met het oog op het inspireren, verbinden en versterken van de TKI's (Topconsortia voor Kennis en Innovatie) en individuele bedrijven en onderzoekers die werken aan energie-innovatie. Dit rapport betreft het onderzoek naar zon PV.

  16. Characterization of Xanthomonas spp. strains by bacteriocins Caracterização de isolados de Xanthomonas spp. por bacterocinas

    Directory of Open Access Journals (Sweden)

    Marcel Bonini

    2007-03-01

    Full Text Available Twenty-five strains of Xanthomonas axonopodis pv. citri and 14 strains of Xanthomonas spp. were tested for bacteriocin production. X. axonopodis pv. passiflorae strains were sensitive to the bacteriocins produced by the 25 X. axonopodis pv. citri strains evaluated in this study while strains of X. axonopodis pv. manihotis and X. campestris pv. campestris showed variable sensitivity. Only five of the 25 X. axonopodis pv. citri strains were not inhibited by the bacteriocins produced by the two X. axonopodis pv. passiflorae strains. The bacteriocins produced by the Xanthomonas axonopodis pv. citri (FDC-806 and X. axonopodis pv. passiflorae (Mar-2850 A strains were thermolabile, resistant to lysozyme and sensitive to DNAse. The bacteriocin produced by X. axonopodis pv. passiflorae was resistant to the action of proteinase K, trypsin and RNAse while the bacteriocin produced by X. axonopodis pv. citri was sensitive to these enzymes. The bacteriocins produced by X. axonopodis pv. passiflorae and X. axonopodis pv. citri were called passifloricin and citricin, respectively.Vinte e cinco isolados de Xanthomonas axonopodis pv. citri e 14 isolados de Xanthomonas spp. foram comparados a fim de verificar a capacidade de produção de bacteriocina e a sua sensibilidade. Isolados de X. axonopodis pv. passiflorae foram sensíveis às bacteriocinas produzidas por 25 isolados de X. axonopodis pv. citri avaliados e os isolados de X. axonopodis pv. manihotis e X. campestris pv. campestris apresentaram sensibilidade variável. Dos 25 isolados de X. axonopodis pv. citri apenas cinco não foram inibidos pelas bacteriocinas produzidas por dois isolados de X. axonopodis pv. passiflorae. As bacteriocinas produzidas pelos isolados de X. axonopodis pv. citri (FDC-806 e de X. axonopodis pv. passiflorae (Mar-2850 A foram termolábeis e resistentes à lisozima e sensíveis a DNAse. A bacteriocina produzida pelo isolado de X. axonopodis pv. passiflorae foi resistente à a

  17. Survey for incidence and severity of bacterial blight of cotton caused by Xanthomonas axonopodis pv. malvacearum in different districts of Marathwada region

    Directory of Open Access Journals (Sweden)

    D. Utpal

    2012-07-01

    Full Text Available An extensive roving survey was conducted in different districts of Marathwada region of Maharashtra State to isolate the pathogen associated with the bacterial blight disease of cotton. In all 76 cotton fields were surveyed and average disease incidence (PI to the tune of 51.12 per cent has been observed. Highest disease incidence noticed in Parbhani district (67% followed by Hingoli (63%, Nanded (58% and Latur (54%. The lowest disease incidence noticed in Jalna district (36%. Highest disease severity noticed in Parbhani district followed by Hingoli, Latur, Nanded and Aurangabad.

  18. PV gold rush in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Daniela

    2011-07-01

    As a result of the Green Energy Act, the installed PV capacity in the Canadian province of Ontario has tripled in the year 2010. A generous feed-in tariff, aiming at maximum local added value, has attracted numerous international manufacturers. However, the rigorous rules committing the companies to 60 % inland production have provoked harsh criticism. (orig.)

  19. Progress & Frontiers in PV Performance

    Energy Technology Data Exchange (ETDEWEB)

    Deline, Chris; DiOrio, Nick; Jordan, Dirk; Toor, Fatima

    2016-09-12

    PowerPoint slides for a presentation given at Solar Power International 2016. Presentation includes System Advisor Model (SAM) introduction and battery modeling, bifacial PV modules and modeling, shade modeling and module level power electronics (MLPE), degradation rates, and PVWatts updates and validation.

  20. The case for better PV forecasting

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Efthymiou, Venizelos; Graditi, Giorgio

    2016-01-01

    Rising levels of PV penetration mean increasingly sophisticated forecasting technologies are needed to maintain grid stability and maximise the economic value of PV systems. The Grid Integration working group of the European Technology and Innovation Platform – Photovoltaics (ETIP PV) shares...... the results of its ongoing research into the advantages and limitations of current forecasting technologies....

  1. Grid Integrated Distributed PV (GridPV) Version 2.

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle

    2014-12-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functio ns are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in th e OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function i n the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  2. Lightweight IMM PV Flexible Blanket Assembly

    Science.gov (United States)

    Spence, Brian

    2015-01-01

    Deployable Space Systems (DSS) has developed an inverted metamorphic multijunction (IMM) photovoltaic (PV) integrated modular blanket assembly (IMBA) that can be rolled or z-folded. This IMM PV IMBA technology enables a revolutionary flexible PV blanket assembly that provides high specific power, exceptional stowed packaging efficiency, and high-voltage operation capability. DSS's technology also accommodates standard third-generation triple junction (ZTJ) PV device technologies to provide significantly improved performance over the current state of the art. This SBIR project demonstrated prototype, flight-like IMM PV IMBA panel assemblies specifically developed, designed, and optimized for NASA's high-voltage solar array missions.

  3. Lightning protection of PV systems

    OpenAIRE

    Pons, Enrico; Tommasini, Riccardo

    2013-01-01

    Lightning strikes can affect photovoltaic (PV) generators and their installations, involving also the inverter's electronics. It is therefore necessary to evaluate the risk connected to lightning strikes in order to adopt the correct protective measures for the system. The Standard IEC (EN) 62305-2 reports the procedures for the risk calculation and for the choice of proper lightning protection systems. Usually the technical guidelines suggest protecting with SPDs (surge protective devices) b...

  4. PV output smoothing with energy storage.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Schoenwald, David Alan

    2012-03-01

    This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

  5. Effects of distilled Phaseoli Semen rubra Herbal-Acupuncture on lipid composition, liver function, antioxidant capacity and molecular biological aspects in obese rats induced high fat diet

    Directory of Open Access Journals (Sweden)

    Ji, Jun Hwan

    2005-06-01

    Full Text Available Effects of Phaseoli Semen rubra Herbal-acupuncture at zusanli(ST-36, Quchi(LI-11 and Sanyinjiao(Sp-6 on lipid composition, liver function, oxidative capacity and molecular biological aspects were investigate in high fat diet induced obese rats. Forty male Sprague-Dawley rats weighing about 400g were divided into 4 groups according to body weight and raised four weeks with control, zusanli(ST-36, Quchi(LI-11 and Sanyinjiao(Sp-6 Herbal-acupuncture groups. 1. Plasma total cholesterol and LDL-cholesterol showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups and HDL- cholesterol showed a high values in the (ST-36 Herbal-acupuncture groups. 2. Plasma triglyceride and glucose showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups. 3. The contents of plasma free fatty acids showed a tendence to decrease in the Herbal-acupuncture groups, however in the Herbal-acupuncture groups, the values showed no significantly different. 4. The activities of AST and ALT showed no significantly different in all treatment groups. 5. The contents of plasma β-lipoprotein and free fatty acids showed a tendency to decrease in the Herbal-acupuncture groups compared to those of control group. In the Herbal-acupuncture groups, the values of (ST-36 and (LI-11 Herbal-acupuncture groups showed a low in the acupuncture groups. 6. Liver total cholesterol and triglyceride showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups. 7. Contents of plasma TBARS showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups, however contents of liver TBARS showed no significantly different among treatment groups. 8. Values of liver glutathione peroxidase and catalase activity showed a tendency to increase in the (ST-36 and (LI-11 Herbal-acupuncture groups. Values of liver super oxide dismutase activity showed a high in the (ST-36 Herbal-acupuncture groups compared to those of other groups. 9. Expression of apo-B mRNA in liver cell

  6. High-efficiency Transformerless PV Inverter Circuits

    OpenAIRE

    Chen, Baifeng

    2015-01-01

    With worldwide growing demand for electric energy, there has been a great interest in exploring photovoltaic (PV) sources. For the PV generation system, the power converter is the most essential part for the efficiency and function performance. In recent years, there have been quite a few new transformerless PV inverters topologies, which eliminate the traditional line frequency transformers to achieve lower cost and higher efficiency, and maintain lower leakage current as well. With an ov...

  7. Differentially Expressed Genes in Resistant and Susceptible Common Bean (Phaseolus vulgaris L. Genotypes in Response to Fusarium oxysporum f. sp. phaseoli.

    Directory of Open Access Journals (Sweden)

    Renfeng Xue

    Full Text Available Fusarium wilt of common bean (Phaseolus vulgaris L., caused by Fusarium oxysporum Schlechtend.:Fr. f.sp. phaseoli (Fop, is one of the most important diseases of common beans worldwide. Few natural sources of resistance to Fop exist and provide only moderate or partial levels of protection. Despite the economic importance of the disease across multiple crops, only a few of Fop induced genes have been analyzed in legumes. Therefore, our goal was to identify transcriptionally regulated genes during an incompatible interaction between common bean and the Fop pathogen using the cDNA amplified fragment length polymorphism (cDNA-AFLP technique. We generated a total of 8,730 transcript-derived fragments (TDFs with 768 primer pairs based on the comparison of a moderately resistant and a susceptible genotype. In total, 423 TDFs (4.9% displayed altered expression patterns after inoculation with Fop inoculum. We obtained full amplicon sequences for 122 selected TDFs, of which 98 were identified as annotated known genes in different functional categories based on their putative functions, 10 were predicted but non-annotated genes and 14 were not homologous to any known genes. The 98 TDFs encoding genes of known putative function were classified as related to metabolism (22, signal transduction (21, protein synthesis and processing (20, development and cytoskeletal organization (12, transport of proteins (7, gene expression and RNA metabolism (4, redox reactions (4, defense and stress responses (3, energy metabolism (3, and hormone responses (2. Based on the analyses of homology, 19 TDFs from different functional categories were chosen for expression analysis using quantitative RT-PCR. The genes found to be important here were implicated at various steps of pathogen infection and will allow a better understanding of the mechanisms of defense and resistance to Fop and similar pathogens. The differential response genes discovered here could also be used as

  8. Electrical PV array reconfiguration strategy for energy extraction improvement in grid-connected PV systems

    OpenAIRE

    2009-01-01

    This paper applies a dynamical electrical array reconfiguration (EAR) strategy on the photovoltaic (PV) generator of a grid-connected PV system based on a plant-oriented configuration, in order to improve its energy production when the operating conditions of the solar panels are different. The EAR strategy is carried out by inserting a controllable switching matrix between the PV generator and the central inverter, which allows the electrical reconnection of the available PV modules. A...

  9. 46 CFR 153.355 - PV venting systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false PV venting systems. 153.355 Section 153.355 Shipping... Systems § 153.355 PV venting systems. When Table 1 requires a PV venting system, the cargo tank must have a PV valve in its vent line. The PV valve must be located between the tank and any connection...

  10. Chemical Composition and Antibacterial Activity of Essential Oils of Tagetes minuta (Asteraceae) against Selected Plant Pathogenic Bacteria

    Science.gov (United States)

    Wagacha, John M.; Dossaji, Saifuddin F.

    2016-01-01

    The objective of this study was to determine the chemical composition and antibacterial activity of essential oils (EOs) of Tagetes minuta against three phytopathogenic bacteria Pseudomonas savastanoi pv. phaseolicola, Xanthomonas axonopodis pv. phaseoli, and Xanthomonas axonopodis pv. manihotis. The essential oils were extracted using steam distillation method in a modified Clevenger-type apparatus while antibacterial activity of the EOs was evaluated by disc diffusion method. Gas chromatography coupled to mass spectrometry (GC/MS) was used for analysis of the chemical profile of the EOs. Twenty compounds corresponding to 96% of the total essential oils were identified with 70% and 30% of the identified components being monoterpenes and sesquiterpenes, respectively. The essential oils of T. minuta revealed promising antibacterial activities against the test pathogens with Pseudomonas savastanoi pv. phaseolicola being the most susceptible with mean inhibition zone diameters of 41.83 and 44.83 mm after 24 and 48 hours, respectively. The minimum inhibitory concentrations and minimum bactericidal concentrations of the EOs on the test bacteria were in the ranges of 24–48 mg/mL and 95–190 mg/mL, respectively. These findings provide a scientific basis for the use of T. minuta essential oils as a botanical pesticide for management of phytopathogenic bacteria. PMID:27721831

  11. 40 CFR 180.1261 - Xanthomonas campestris pv. vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages.

    Science.gov (United States)

    2010-07-01

    ... and Pseudomonas syringae pv. tomato specific Bacteriophages. 180.1261 Section 180.1261 Protection of.... vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages. An exemption from the requirement of... syringae pv. tomato specific bacteriophages in or on pepper and tomato....

  12. Adiabatic Rearrangement of Hollow PV Towers

    Directory of Open Access Journals (Sweden)

    Eric A Hendricks

    2010-10-01

    Full Text Available Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV. This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with significant vortex structural and intensity change. The three-dimensional adiabatic rearrangements of two prototypical hurricane-like hollow PV towers (one thick and one thin are examined in an idealized framework. For both hollow towers, dynamic instability causes air parcels with high PV to be mixed into the eye preferentially at lower levels, where unstable PV wave growth rates are the largest. Little or no mixing is found to occur at upper levels. The mixing at lower and middle levels is most rapid for the breakdown of the thin hollow tower, consistent with previous barotropic results. For both hollow towers, this advective rearrangement of PV affects the tropical cyclone structure and intensity in a number of ways. First, the minimum central pressure and maximum azimuthal mean velocity simultaneously decrease, consistent with previous barotropic results. Secondly, isosurfaces of absolute angular momentum preferentially shift inward at low levels, implying an adiabatic mechanism by which hurricane eyewall tilt can form. Thirdly, a PV bridge, similar to that previously found in full-physics hurricane simulations, develops as a result of mixing at the isentropic levels where unstable PV waves grow most rapidly. Finally, the balanced mass field resulting from the PV rearrangement is warmer in the eye between 900 and 700 hPa. The location of this warming is consistent with observed warm anomalies in the eye, indicating that in certain instances the hurricane

  13. Multilocus Sequence Typing Reveals Relevant Genetic Variation and Different Evolutionary Dynamics among Strains of Xanthomonas arboricola pv. juglandis

    Directory of Open Access Journals (Sweden)

    Marco Scortichini

    2010-11-01

    Full Text Available Forty-five Xanthomonas arboricola pv. juglandis (Xaj strains originating from Juglans regia cultivation in different countries were molecularly typed by means of MultiLocus Sequence Typing (MLST, using acnB, gapA, gyrB and rpoD gene fragments. A total of 2.5 kilobases was used to infer the phylogenetic relationship among the strains and possible recombination events. Haplotype diversity, linkage disequilibrium analysis, selection tests, gene flow estimates and codon adaptation index were also assessed. The dendrograms built by maximum likelihood with concatenated nucleotide and amino acid sequences revealed two major and two minor phylotypes. The same haplotype was found in strains originating from different continents, and different haplotypes were found in strains isolated in the same year from the same location. A recombination breakpoint was detected within the rpoD gene fragment. At the pathovar level, the Xaj populations studied here are clonal and under neutral selection. However, four Xaj strains isolated from walnut fruits with apical necrosis are under diversifying selection, suggesting a possible new adaptation. Gene flow estimates do not support the hypothesis of geographic isolation of the strains, even though the genetic diversity between the strains increases as the geographic distance between them increases. A triplet deletion, causing the absence of valine, was found in the rpoD fragment of all 45 Xaj strains when compared with X. axonopodis pv. citri strain 306. The codon adaptation index was high in all four genes studied, indicating a relevant metabolic activity.

  14. Multifunctionality of PV shells; Multifunktionalitaet von PV-Fassaden

    Energy Technology Data Exchange (ETDEWEB)

    Erban, C. [Saint-Gobain Glass Solar, Aachen (Germany)

    2000-08-01

    Integrated PV systems have come a long way since the construciton of the first solar building shell eight years ago. All technical problems have be solved, and a multitude of solar wall elements are now available that enable architects and planners to design their own customised solar building. [German] Der Einsatz von gebaeudeintegrierter Photovoltaik hat in den nunmehr acht Jahren seit dem Bau der ersten Solarfassade erhebliche Fortschritte gemacht. In technischer Hinsicht ist heute nahezu alles moeglich. Der Umsetzung der einstigen Vision 'Jedem Gebaeude seine Solaranlage' steht heute nichts mehr entgegen, zumal zahlreiche Foerdermoeglichkeiten existieren. Die Vielzahl der Einsatz- und Kombinationsmoeglichkeiten von Solar-Fassadenelementen versetzen Planer und Architekten in die Lage, ihrer individuellen Idee einer gebaeudeintegrierten Solaranlage Gestalt zu geben. (orig.)

  15. Distributed PV Adoption - Sensitivity to Market Factors

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2016-02-01

    NREL staff used the dSolar (distributed solar) model to forecast the adoption of distributed, behind-the-meter PV through the year 2050 for 9 different scenarios. The scenarios varied in their assumptions about a carbon tax, the cost of PV systems in the future, and what credit would be given for excess generation once current net metering policies expire.

  16. Optimal design of PV and HP system

    DEFF Research Database (Denmark)

    Nepper-Rasmussen, Bjarke Christian; Rasmussen, Theis Bo

    2015-01-01

    electric energy demand of the HP to hours where excess PV power is present. The self-consumption of the PV energy affects the overall net present value (NPV). In this paper, a method which maximizes the NPV by finding the cost-optimal combination of PV, HP and BT sizes, is proposed. Results show...... that the thermal storage with a BT is a better investment than a PV system without HP or no investment. Furthermore, it showed that the optimization model developed in this project is capable of finding the optimal combination of component sizes based on our data....... is described, where the thermal energy is stored in a buffer tank (BT) capable of dispersing heat to either the heating system of a house or a hot water tank, for later use. The thermal storage solution including a BT can increase the self-consumption of residentially produced PV power and thereby shift...

  17. Global PV markets and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Wolfsegger, Cristoph [European Photolvoltaic Industry Association (EPIA), Brussels, Belgium (Belgium)

    2007-06-15

    This presentation mainly talks about the global importance of the PV industry, not only in the environmental sphere but also in the economic sphere. It is firstly given the major information of the European Photovoltaic Industry Association (EPIA), where there can be found the lists of those full member countries that work as: components manufacturers, consulting, and associate members. Then, it is given a briefly explanation about the Alliance for Rural Electrification (ARE), and the reasons why the -PV systems- are almost the panacea to both the energy and the environmental issue. In addition, it is given the most relevant information about how to implement this system in those regions that have not yet implemented it. Besides, there are explained some of the benefits that this system has. It is shortly explained how this system is working in German and it is also shown a comparison chart about the photovoltaic feed-in tariffs. There are shown some graphics and charts having information related to the global markets and the global installations of PV systems and other issues related to them. [Spanish] Esta presentacion habla principalmente acerca de la importancia que hoy en dia tiene la industria fotovoltaica alrededor del mundo, esto no solo ocurre en el ambito ambiental sino tambien en el economico. En la primer parte se muestra la informacion mas importante acerca de la Asociacion Europea de la Industria Fotovoltaica (EPIA por sus siglas en ingles), en donde se encuentran las listas de los paises que son miembros permanentes trabajando como: fabricantes de componentes, asesores y miembros asociados. Enseguida, se da, de manera escueta, una explicacion acerca de la ARE, asi como las razones por las que los sistemas fotovoltaicos son casi la panacea tanto para los problemas ambientales como para los energeticos. Ademas, se explica la informacion mas relevante acerca de como implementar este sistema en aquellas partes del mundo que todavia no lo han realizado

  18. Multifunctional a-Si PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Peippo, K.; Lund, P.; Vartiainen, E. [Helsinki Univ. of Technology, Otaniemi (Finland). Advanced Energy Systems

    1998-10-01

    The optimal use of the various forms of solar energy (passive, active, daylighting, photovoltaics) in buildings calls for an optimal integration of the technologies. As energy conservation potential in space heating may soon be exhausted, electricity efficiency and on-site generation will play an increasing role in energy-conscious building design. There, dispersed PV systems integrated into buildings show a significant market potential, due to a number of benefits: no extra land area is required, PV-array may replace conventional cladding materials and become a building element. Moreover, the produced PV-electricity is more valuable for the building owner than for an electric utility

  19. Design optimization of grid-connected PV inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    , state-of-the-art PV inverters design technology, which limits the amount of PV energy supplied into the electric grid. The influences of the electric grid regulations and standards and the PV array operational characteristics on the design of grid-connected PV inverters have also been considered...

  20. Rating PV Power and Energy: Cell, Module, and System Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith

    2016-06-02

    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  1. A Practical Optimization Method for Designing Large PV Plants

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Koutroulis, E.; Eyigun, S.

    2011-01-01

    Nowadays Photovoltaic (PV) plants have multi MW sizes, the biggest plants reaching tens of MW of capacity. Such large-scale PV plants are made up of several thousands of PV panels, each panel being in the range of 150-350W. This means that the design of a Large PV power plant is a big challenge...

  2. Distributed PV Adoption in Maine Through 2021

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2015-11-06

    NREL has used its dSolar (distributed solar) model to generate low-medium-high estimates of distributed PV adoption in Maine through 2021. This presentation gives a high-level overview of the model and modeling results.

  3. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    to be used in commercial PV inverters for the measurement of leakage and fault ground currents. The German VDE0126–1–1 standard gives the limit for fault and leakage ground currents and all grid connected PV inverters have to comply with these limits and disconnect from the grid in case of a fault.......Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  4. Transformerless PV inverters. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Borup, U.

    2009-12-15

    Since the start of the project the market for grid connected PV inverters have developed further. When the project started three - phase inverter were only available in high power systems. The technology developed within this project will enable three phase technology also to be implemented in string inverters for system down to 10 kW. We expect this to be very attractive due to the increased demand for symmetrical feed-in to the grid. The project relevance is therefore high and the sector continues to develop very much driven by technology. Especially the inverter technology is getting a lot of focus. The inverter systems are expected to take a much larger role in supporting the electrical grid in the future. The technology platform developed within the project is prepared to be extended with these utility functionalities. The main results of the project were: 1) A new technology concept for transformer-less inverters has been demonstrated with a number of prototypes. 2) Efficiency above 97,7% has been proven. 3) Efficiency and Maximum power point tracking has been optimized to ensure that almost all energy produced of the panels is transferred to the grid. 4) The platform is developed with a very fast control board, which enables extended functionality as demanding grid supporting functions in the future. Details about cost price and details about the control loop implementation is excluded from the report due to the competitive situation for Danfoss Solar Inverters A/S. (LN)

  5. Addressing firefighter safety around solar PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Harris, B. [Sustainable Energy Technologies, Calgary, AB (Canada)

    2010-11-15

    The article discussed new considerations for installing photovoltaic (PV) systems that address the needs of fire service personnel. The presence of a PV system presents a multitude of dangers for firefighters, including electrical shock, the inhalation of toxic gases from being unable to cut a hole through the roof, falling debris and flying glass, and dead loading on a compromised structure and tripping on conduits. Mapping systems should be modified so that buildings with PV systems are identified for first responders, including firefighters who should learn that solar modules present an electrical hazard during the day but not at night; covering PV modules with foam or salvage covers may not shut the system down to a safe level; it takes a few moments for the power in PV modules to reduce to zero; and PV modules or conduit should never be cut, broke, chopped, or walked upon. The California Department of Forestry and Fire Protection recommends creating pathways and allowing easier access to the roof by setting the modules back from roof edges, creating a structurally sound pathway for firefighters to walk on and space to cut ventilation holes. However, the setback rule makes the economics of solar installation less viable for residential applications. The technological innovations aimed at addressing system safety all focus on limiting firefighter contact with live electrical components to within the extra-low-voltage (ELV) band. Some of the inverters on the market that support ELV system architecture were described. 1 fig.

  6. Updating Technical Screens for PV Interconnection: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Ellis, A.; Lynn, K.; Razon, A.; Key, T.; Kroposki, B.; Mather, B.; Hill, R.; Nicole, K.; Smith, J.

    2012-08-01

    Solar photovoltaics (PV) is the dominant type of distributed generation (DG) technology interconnected to electric distribution systems in the United States, and deployment of PV systems continues to increase rapidly. Considering the rapid growth and widespread deployment of PV systems in United States electric distribution grids, it is important that interconnection procedures be as streamlined as possible to avoid unnecessary interconnection studies, costs, and delays. Because many PV interconnection applications involve high penetration scenarios, the process needs to allow for a sufficiently rigorous technical evaluation to identify and address possible system impacts. Existing interconnection procedures are designed to balance the need for efficiency and technical rigor for all DG. However, there is an implicit expectation that those procedures will be updated over time in order to remain relevant with respect to evolving standards, technology, and practical experience. Modifications to interconnection screens and procedures must focus on maintaining or improving safety and reliability, as well as accurately allocating costs and improving expediency of the interconnection process. This paper evaluates the origins and usefulness of the capacity penetration screen, offers potential short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen.

  7. Variation suggestive of horizontal gene transfer at a lipopolysaccharide (lps) biosynthetic locus in Xanthomonas oryzae pv. oryzae, the bacterial leaf blight pathogen of rice

    Science.gov (United States)

    Patil, Prabhu B; Sonti, Ramesh V

    2004-01-01

    Background In animal pathogenic bacteria, horizontal gene transfer events (HGT) have been frequently observed in genomic regions that encode functions involved in biosynthesis of the outer membrane located lipopolysaccharide (LPS). As a result, different strains of the same pathogen can have substantially different lps biosynthetic gene clusters. Since LPS is highly antigenic, the variation at lps loci is attributed to be of advantage in evading the host immune system. Although LPS has been suggested as a potentiator of plant defense responses, interstrain variation at lps biosynthetic gene clusters has not been reported for any plant pathogenic bacterium. Results We report here the complete sequence of a 12.2 kb virulence locus of Xanthomonas oryzae pv. oryzae (Xoo) encoding six genes whose products are homologous to functions involved in LPS biosynthesis and transport. All six open reading frames (ORFs) have atypical G+C content and altered codon usage, which are the hallmarks of genomic islands that are acquired by horizontal gene transfer. The lps locus is flanked by highly conserved genes, metB and etfA, respectively encoding cystathionine gamma lyase and electron transport flavoprotein. Interestingly, two different sets of lps genes are present at this locus in the plant pathogens, Xanthomonas campestris pv. campestris (Xcc) and Xanthomonas axonopodis pv. citri (Xac). The genomic island is present in a number of Xoo strains from India and other Asian countries but is not present in two strains, one from India (BXO8) and another from Nepal (Nepal624) as well as the closely related rice pathogen, Xanthomonas oryzae pv. oryzicola (Xoor). TAIL-PCR analysis indicates that sequences related to Xac are present at the lps locus in both BXO8 and Nepal624. The Xoor strain has a hybrid lps gene cluster, with sequences at the metB and etfA ends, being most closely related to sequences from Xac and the tomato pathogen, Pseudomonas syringae pv. tomato respectively

  8. A transcription activator-like effector from Xanthomonas oryzae pv. oryzicola elicits dose-dependent resistance in rice.

    Science.gov (United States)

    Hummel, Aaron W; Wilkins, Katherine E; Wang, Li; Cernadas, R Andres; Bogdanove, Adam J

    2017-01-01

    Xanthomonas spp. reduce crop yields and quality worldwide. During infection of their plant hosts, many strains secrete transcription activator-like (TAL) effectors, which enter the host cell nucleus and activate specific corresponding host genes at effector binding elements (EBEs) in the promoter. TAL effectors may contribute to disease by activating the expression of susceptibility genes or trigger resistance associated with the hypersensitive reaction (HR) by activating an executor resistance (R) gene. The rice bacterial leaf streak pathogen X. oryzae pv. oryzicola (Xoc) is known to suppress host resistance, and no host R gene has been identified against it, despite considerable effort. To further investigate Xoc suppression of host resistance, we conducted a screen of effectors from BLS256 and identified Tal2a as an HR elicitor in rice when delivered heterologously by a strain of the closely related rice bacterial blight pathogen X. oryzae pv. oryzae (Xoo) or by the soybean pathogen X. axonopodis pv. glycines. The HR required the Tal2a activation domain, suggesting an executor R gene. Tal2a activity was differentially distributed among geographically diverse Xoc isolates, being largely conserved among Asian isolates. We identified four genes induced by Tal2a in next-generation RNA sequencing experiments and confirmed them using quantitative real-time reverse transcription-polymerase chain reaction (qPCR). However, neither individual nor collective activation of these genes by designer TAL effectors resulted in HR. A tal2a knockout mutant of BLS256 showed virulence comparable with the wild-type, but plasmid-based overexpression of tal2a at different levels in the wild-type reduced virulence in a directly corresponding way. Overall, the results reveal that host resistance suppression by Xoc plays a critical role in pathogenesis. Further, the dose-dependent avirulence activity of Tal2a and the apparent lack of a single canonical target that accounts for HR point to

  9. Optimization of PV-based energy production by dynamic PV-panel/inverter configuration

    DEFF Research Database (Denmark)

    Paasch, Kasper; Nymand, Morten; Haase, Frerk

    This paper investigates the possible increase in annual energy production of a PV system with more than one MPPT (maximum power point tracker) input channels under Nordic illumination conditions, in case a concept of dynamic switching of the PV panels is used at the inputs of the inverters....

  10. Custo adaptativo da indução de resistência em feijoeiro mediada pela rizobactéria Bacillus cereus ou acibenzolar-S-metil: atividade de enzimas, síntese de fenóis e lignina e biomassa Fitness cost of induced resistance in bean plants by the rhizobacteria Bacillus cereus or acibenzolar-S-methyl: enzymes activities, phenol and lignin synthesis, and biomass

    Directory of Open Access Journals (Sweden)

    Odair José Kuhn

    2010-06-01

    Full Text Available Plantas que utilizam recursos para defesa na ausência de pragas ou patógenos, arcarão com custos energéticos que podem refletir na sua produtividade. Assim, teve-se por objetivo avaliar os custos adaptativos da indução de resistência, antes da chegada do patógeno, em feijoeiro induzido por um indutor biótico (Bacillus cereus e um abiótico (acibenzolar-S-metil, ASM, em 2, 3 ou 4 aplicações distribuídas ao longo do ciclo da cultura. Avaliou-se o efeito protetor contra a bactéria Xanthomonas axonopodis pv. phaseoli, além da atividade de peroxidase, quitinase, β-1,3-glucanase, síntese de lignina, fenóis e crescimento com base na matéria seca. Observou-se que os indutores protegeram a cultura contra X. axonopodis pv. phaseoli com base na redução da severidade. O ASM aumentou a atividade de peroxidase, quitinase e β-1,3-glucanase, enquanto que o B. cereus aumentou apenas a peroxidase. O ASM aumentou a síntese de lignina e B. cereus não, enquanto que ASM diminuiu teor de fenóis e B. cereus não. O ASM reduziu a biomassa da planta, o que não ocorreu em plantas induzidas por B. cereus. Portanto, a resistência induzida por ASM apresenta elevado custo associado, enquanto que por B. cereus apresenta baixo custo, necessitando a indução de resistência ser melhor explorada e estudada para potencializar seu uso em feijoeiro.Plants that use resources to defend themselves in the absence of pests or pathogens will pay off with energy costs that can reflect in the productivity. Thus, the objective of this work was to evaluate the fitness costs of the resistance induced in bean plants, before the presence of the pathogen, by using biotic (Bacillus cereus and abiotic (acibenzolar-S-methyl, ASM inducers, applied 2, 3 or 4 times during the cycle of the culture. The protecting effect was evaluated against the bacterium Xanthomonas axonopodis pv. phaseoli. The activities of peroxidase, chitinase and β-1,3-glucanase, lignin and phenol

  11. PV system field experience and reliability

    Science.gov (United States)

    Durand, Steven; Rosenthal, Andrew; Thomas, Mike

    1997-02-01

    Hybrid power systems consisting of battery inverters coupled with diesel, propane, or gasoline engine-driven electrical generators, and photovoltaic arrays are being used in many remote locations. The potential cost advantages of hybrid systems over simple engine-driven generator systems are causing hybrid systems to be considered for numerous applications including single-family residential, communications, and village power. This paper discusses the various design constraints of such systems and presents one technique for reducing hybrid system losses. The Southwest Technology Development Institute under contract to the National Renewable Energy Laboratory and Sandia National Laboratories has been installing data acquisition systems (DAS) on a number of small and large hybrid PV systems. These systems range from small residential systems (1 kW PV - 7 kW generator), to medium sized systems (10 kW PV - 20 kW generator), to larger systems (100 kW PV - 200 kW generator). Even larger systems are being installed with hundreds of kilowatts of PV modules, multiple wind machines, and larger diesel generators.

  12. PV performance modeling workshop summary report.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua S.; Tasca, Coryne Adelle (SRA International, Inc., Fairfax, VA); Cameron, Christopher P.

    2011-05-01

    During the development of a solar photovoltaic (PV) energy project, predicting expected energy production from a system is a key part of understanding system value. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, annual energy yield (kWh/kWp) will vary among module technologies because of differences in response to low-light levels and temperature. A number of PV system performance models have been developed and are in use, but little has been published on validation of these models or the accuracy and uncertainty of their output. With support from the U.S. Department of Energy's Solar Energy Technologies Program, Sandia National Laboratories organized a PV Performance Modeling Workshop in Albuquerque, New Mexico, September 22-23, 2010. The workshop was intended to address the current state of PV system models, develop a path forward for establishing best practices on PV system performance modeling, and set the stage for standardization of testing and validation procedures for models and input parameters. This report summarizes discussions and presentations from the workshop, as well as examines opportunities for collaborative efforts to develop objective comparisons between models and across sites and applications.

  13. PV Systems Reliability Final Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.

  14. POWERED LED LIGHTING SUPPLIED FROM PV CELLS

    Directory of Open Access Journals (Sweden)

    Tirshu M.

    2011-12-01

    Full Text Available The paper deals with practical realization of efficient lighting system based on LED’s of 80W total power mounted on corridor ceiling total length of which is 120m and substitutes existing traditional lighting system consisting of 29 lighting blocks with 4 fluorescent lamps each of them and summary power 2088W. Realized lighting system is supplied from two photovoltaic panels of power 170W. Generated energy by PV cells is accumulated in two accumulators of 75Ah capacity and from battery by means of specialized convertor is applied to lighting system. Additionally, paper present data measured by digital weather station (solar radiation and UV index, which is mounted near of PV cells and comparative analyze of solar energy with real energy generated by PV cells is done. Measured parameters by digital weather station are stored by computer in on-line mode.

  15. Terawatt Challenge for Thin-Film PV

    Energy Technology Data Exchange (ETDEWEB)

    Zweibel, K.

    2005-08-01

    The evolution of PV into one of the world's largest industries is not going to happen without major unforeseen problems. However, this study attempts to address the obvious ones, so that we can put aside the mythology of PV (for example, that it is only ''boutique power'' or that one must pave the world with it to be useful) and get on with changing the world's energy infrastructure. With the years of rapid market growth now under way in PV, the author is sure this will not be the last effort to understand the real potential and pitfalls of meeting the Challenge.

  16. Real time PV manufacturing diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Kochergin, Vladimir [MicroXact Inc., Blacksburg, VA (United States); Crawford, Michael A. [MicroXact Inc., Blacksburg, VA (United States)

    2015-09-01

    The main obstacle Photovoltaic (PV) industry is facing at present is the higher cost of PV energy compared to that of fossil energy. While solar cell efficiencies continue to make incremental gains these improvements are so far insufficient to drive PV costs down to match that of fossil energy. Improved in-line diagnostics however, has the potential to significantly increase the productivity and reduce cost by improving the yield of the process. On this Phase I/Phase II SBIR project MicroXact developed and demonstrated at CIGS pilot manufacturing line a high-throughput in-line PV manufacturing diagnostic system, which was verified to provide fast and accurate data on the spatial uniformity of thickness, an composition of the thin films comprising the solar cell as the solar cell is processed reel-to-reel. In Phase II project MicroXact developed a stand-alone system prototype and demonstrated the following technical characteristics: 1) ability of real time defect/composition inconsistency detection over 60cm wide web at web speeds up to 3m/minute; 2) Better than 1mm spatial resolution on 60cm wide web; 3) an average better than 20nm spectral resolution resulting in more than sufficient sensitivity to composition imperfections (copper-rich and copper-poor regions were detected). The system was verified to be high vacuum compatible. Phase II results completely validated both technical and economic feasibility of the proposed concept. MicroXact’s solution is an enabling technique for in-line PV manufacturing diagnostics to increase the productivity of PV manufacturing lines and reduce the cost of solar energy, thus reducing the US dependency on foreign oil while simultaneously reducing emission of greenhouse gasses.

  17. Development of a molecular method for detection and identification of Xanthomonas campestris pv. viticola Desenvolvimento de um método molecular para detecção e identificação de Xanthomonas campestris pv. viticola

    Directory of Open Access Journals (Sweden)

    Loiselene Carvalho da Trindade

    2007-03-01

    Full Text Available In order to develop a molecular method for detection and identification of Xanthomonas campestris pv. viticola (Xcv the causal agent of grapevine bacterial canker, primers were designed based on the partial sequence of the hrpB gene. Primer pairs Xcv1F/Xcv3R and RST2/Xcv3R, which amplified 243- and 340-bp fragments, respectively, were tested for specificity and sensitivity in detecting DNA from Xcv. Amplification was positive with DNA from 44 Xcv strains and with DNA from four strains of X. campestris pv. mangiferaeindicae and five strains of X. axonopodis pv. passiflorae, with both primer pairs. However, the enzymatic digestion of PCR products could differentiate Xcv strains from the others. None of the primer pairs amplified DNA from grapevine, from 20 strains of nonpathogenic bacteria from grape leaves and 10 strains from six representative genera of plant pathogenic bacteria. Sensitivity of primers Xcv1F/Xcv3R and RST2/Xcv3R was 10 pg and 1 pg of purified Xcv DNA, respectively. Detection limit of primers RST2/Xcv3R was 10(4 CFU/ml, but this limit could be lowered to 10² CFU/ml with a second round of amplification using the internal primer Xcv1F. Presence of Xcv in tissues of grapevine petioles previously inoculated with Xcv could not be detected by PCR using macerated extract added directly in the reaction. However, amplification was positive with the introduction of an agar plating step prior to PCR. Xcv could be detected in 1 µl of the plate wash and from a cell suspension obtained from a single colony. Bacterium identity was confirmed by RFLP analysis of the RST2/Xcv3R amplification products digested with Hae III.Com o objetivo de desenvolver um método molecular para detecção e identificação de Xanthomonas campestris pv. viticola (Xcv, agente causal do cancro bacteriano da videira, oligonucleotídeos (primers foram desenhados com base na seqüência parcial do gene hrpB. As combinações de primers Xcv1F/Xcv3R e RST2/Xcv3R que

  18. PV panel model based on datasheet values

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    2007-01-01

    This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell....../panel in Standard Test Conditions (STC) are shown, as well as the parameters extraction from the data-sheet values. The temperature dependence of the cell dark saturation current is expressed with an alternative formula, which gives better correlation with the datasheet values of the power temperature dependence...

  19. MPPT algorithm for voltage controlled PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco;

    2008-01-01

    This paper presents a novel concept for an MPPT that can be used in case of a voltage controlled grid connected PV inverters. In case of single-phase systems, the 100 Hz ripple in the AC power is also present on the DC side. Depending on the DC link capacitor, this power fluctuation can be used t...... to track the MPP of the PV array, using the information that at MPP the power oscillations are very small. In this way the algorithm can detect the fact that the current working point is at the MPP, for the current atmospheric conditions....

  20. Updating Interconnection Screens for PV System Integration

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Mather, B.; Kroposki, B.; Lynn, K.; Razon, A.; Ellis, A.; Hill, R.; Key, T.; Nicole, K.; Smith, J.

    2012-02-01

    This white paper evaluates the origins and usefulness of the capacity penetration screen, offer short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen. Short-term and longer-term alternatives approaches are offered as examples; however, specific modifications to screening procedures should be discussed with stakeholders and must ultimately be adopted by state and federal regulatory bodies.

  1. Large-Scale PV Integration Study

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Shuai; Etingov, Pavel V.; Diao, Ruisheng; Ma, Jian; Samaan, Nader A.; Makarov, Yuri V.; Guo, Xinxin; Hafen, Ryan P.; Jin, Chunlian; Kirkham, Harold; Shlatz, Eugene; Frantzis, Lisa; McClive, Timothy; Karlson, Gregory; Acharya, Dhruv; Ellis, Abraham; Stein, Joshua; Hansen, Clifford; Chadliev, Vladimir; Smart, Michael; Salgo, Richard; Sorensen, Rahn; Allen, Barbara; Idelchik, Boris

    2011-07-29

    This research effort evaluates the impact of large-scale photovoltaic (PV) and distributed generation (DG) output on NV Energy’s electric grid system in southern Nevada. It analyzes the ability of NV Energy’s generation to accommodate increasing amounts of utility-scale PV and DG, and the resulting cost of integrating variable renewable resources. The study was jointly funded by the United States Department of Energy and NV Energy, and conducted by a project team comprised of industry experts and research scientists from Navigant Consulting Inc., Sandia National Laboratories, Pacific Northwest National Laboratory and NV Energy.

  2. Seasonal energy storage - PV-hydrogen systems

    Energy Technology Data Exchange (ETDEWEB)

    Leppaenen, J. [Neste Oy/NAPS (Finland)

    1998-10-01

    PV systems are widely used in remote areas e.g. in telecommunication systems. Typically lead acid batteries are used as energy storage. In northern locations seasonal storage is needed, which however is too expensive and difficult to realise with batteries. Therefore, a PV- battery system with a diesel backup is sometimes used. The disadvantages of this kind of system for very remote applications are the need of maintenance and the need to supply the fuel. To overcome these problems, it has been suggested to use hydrogen technologies to make a closed loop autonomous energy storage system

  3. International PV QA Task Force's Proposed Comparative Rating System for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, J.; Kurtz, S.

    2014-10-01

    The International PV Quality Assurance Task Force is developing a rating system that provides comparative information about the relative durability of PV modules. Development of accelerated stress tests that can provide such comparative information is seen as a major step toward being able to predict PV module service life. This paper will provide details of the ongoing effort to determine the format of such an overall module rating system. The latest proposal is based on using three distinct climate zones as defined in IEC 60721-2-1 for two different mounting systems. Specific stresses beyond those used in the qualification tests are being developed for each of the selected climate zones.

  4. NCBI nr-aa BLAST: CBRC-XTRO-01-0625 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-0625 ref|NP_642734.1| integral membrane protein [Xanthomonas axonopodi...s pv. citri str. 306] gb|AAM37270.1| integral membrane protein [Xanthomonas axonopodis pv. citri str. 306] NP_642734.1 1e-62 27% ...

  5. PV-mooduli toodang suurfarmis / Teolan Tomson

    Index Scriptorium Estoniae

    Tomson, Teolan, 1932-

    2015-01-01

    Artiklis uuritakse PV-paneelide tootlikkuse langust nende vastastikuse varjutamise tõttu. Näidatakse, et Eesti oludes on soovitav kasutada paneelide madalaid kaldenurki ja suhtelist reavahet, mis ületab paneeli kõrguse pooleteistkordset väärtust

  6. PV producers must advertise; Werbung wird wichtiger

    Energy Technology Data Exchange (ETDEWEB)

    Seltmann, T.

    2001-01-12

    Producers of current inverters are profiting from the growing PV market. The bigger suppliers are enhancing their advertising and marketing efforts while smaller suppliers opt for high-efficiency technology. [German] Vom kraeftigen Wachstum des Photovoltaik-Marktes profitieren zwangslaeufig auch die Wechselrichter-Hersteller. Die groesseren Anbieter verstaerken Vertrieb und Marketing, waehrend die kleineren versuchen, mit besonders effizienter Technik zu glaenzen. (orig.)

  7. Final Technical Report: PV Fault Detection Tool.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The PV Fault Detection Tool project plans to demonstrate that the FDT can (a) detect catastrophic and degradation faults and (b) identify the type of fault. This will be accomplished by collecting fault signatures using different instruments and integrating this information to establish a logical controller for detecting, diagnosing and classifying each fault.

  8. TRNSYS HYBRID wind diesel PV simulator

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, P.J.A.; Mitchell, J.W.; Klein, S.A.; Beckman, W.A.; Blair, N.J. [Univ. of Wisconsin, Madison, WI (United States)

    1996-12-31

    The Solar Energy Laboratory (SEL) has developed a wind diesel PV hybrid systems simulator, UW-HYBRID 1.0, an application of the TRNSYS 14.2 time-series simulation environment. An AC/DC bus links up to five diesels and wind turbine models, along with PV modules, a battery bank, and an AC/DC converter. Multiple units can be selected. PV system simulations include solar angle and peak power tracking options. Weather data are Typical Meteorological Year data, parametrically generated synthesized data, or external data files. PV performance simulations rely on long-standing SEL-developed algorithms. Loads data are read as scalable time series. Diesel simulations include estimated fuel-use and waste heat output, and are dispatched using a least-cost of fuel strategy. Wind system simulations include varying air density, wind shear and wake effects. Time step duration is user-selectable. UW-HYBRID 1.0 runs in Windows{reg_sign}, with TRNSED providing a customizable user interface. 12 refs., 6 figs.

  9. PV/T slates - Pilot project in Steinhausen; PV/T-Schiefer. Pilotprojekt Steinhausen

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report deals with a ventilated PV-tile system (PV/T-Slates) mounted on a garden shed in Steinhausen, Switzerland. The installation provides power and heat to the main house. The report describes the construction and operation of this pilot project and the results of measurements made on its electrical and thermal performance. The results of measurements made are presented in detail in graphical form and compared with the results of simulation. Suggestions are made for the optimisation of the system. Figures are presented on energy production and energy flows in graphical form.

  10. Commercialization of PV-powered pumping systems for use in utility PV service programs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project described in this report was a commercialization effort focused on cost-effective remote water pumping systems for use in utility-based photovoltaic (PV) service programs. The project combined a commercialization strategy tailored specifically for electric utilities with the development of a PV-powered pumping system that operates conventional ac pumps rather than relying on the more expensive and less reliable PV pumps on the market. By combining these two attributes, a project goal was established of creating sustained utility purchases of 250 PV-powered water pumping systems per year. The results of each of these tasks are presented in two parts contained in this Final Summary Report. The first part summarizes the results of the Photovoltaic Services Network (PSN) as a new business venture, while the second part summarizes the results of the Golden Photon system installations. Specifically, results and photographs from each of the system installations are presented in this latter part.

  11. High Resolution PV Power Modeling for Distribution Circuit Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  12. Remote and Centralized Monitoring of PV Power Plants

    DEFF Research Database (Denmark)

    Kopacz, Csaba; Spataru, Sergiu; Sera, Dezso

    2014-01-01

    the inverters within each PV plant. The monitoring software stores the PV measurements in a data warehouse optimized for managing and data mining large amounts of data, from where it can be later visualized, analyzed and exported. By combining PV production measurements data with I-V curve measurements...

  13. Determination of Parameters of PV Concentrating System With Heliostat

    Science.gov (United States)

    Vardanyan, R.; Norsoyan, A.; Dallakyan, V.

    2010-10-01

    The structure of PV concentrating system with heliostat is analyzed. The mathematical model of system consisting of PV concentrating module and heliostat is developed. With the use of developed mathematical model the optimal parameters of the system are determined. The results of this work can be used during the design of PV concentrating systems with heliostats.

  14. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module...

  15. Beacons In Brief. P/PV In Brief. Issue 2

    Science.gov (United States)

    Blank, Susan; Farley, Chelsea

    2004-01-01

    This second issue in P/PV's "In Brief" series focuses on the San Francisco Beacon Initiative and P/PV's recently released evaluation results. The Beacon Initiative established after-school programs in eight public schools in low-income San Francisco neighborhoods. P/PV's 36-month evaluation examined key developmental and academic outcomes.…

  16. Voltage rise mitigation for solar PV integration at LV grids

    DEFF Research Database (Denmark)

    Yang, Guangya; Marra, Francesco; Juamperez Goñi, Miguel Angel

    2015-01-01

    Solar energy from photovoltaic (PV) is among the fastest developing renewable energy systems worldwide. Driven by governmental subsidies and technological development, Europe has seen a fast expansion of solar PV in the last few years. Among the installed PV plants, most of them are situated...... at the distribution systems and bring various operational challenges such as power quality and power flow management. The paper discusses the modelling requirements for PV system integration studies, as well as the possible techniques for voltage rise mitigation at low voltage (LV) grids for increasing PV penetration...

  17. Technologies to Increase PV Hosting Capacity in Distribution Feeders

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Gotseff, Peter

    2016-11-14

    This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

  18. Technologies to Increase PV Hosting Capacity in Distribution Feeders: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Gotseff, Peter

    2016-08-01

    This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

  19. PV_LIB Toolbox v. 1.3

    Energy Technology Data Exchange (ETDEWEB)

    2015-12-09

    PV_LIB comprises a library of Matlab? code for modeling photovoltaic (PV) systems. Included are functions to compute solar position and to estimate irradiance in the PV system’s plane of array, cell temperature, PV module electrical output, and conversion from DC to AC power. Also included are functions that aid in determining parameters for module performance models from module characterization testing. PV_LIB is open source code primarily intended for research and academic purposes. All algorithms are documented in openly available literature with the appropriate references included in comments within the code.

  20. Impact of Rooftop Solar PV on Residential Distribution Network

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    Increased environmental awareness in recent years has encouraged rapid growth of renewable energy sources especially solar PV and wind. Among them, small scale solar PV has been gaining more momentum especially at residential level. Even today moderate penetration of grid tied rooftop solar PV has...... become reality in many countries. In spite of various benefits, higher penetration of rooftop PVs might come up with number of detrimental effects, with power quality and overcurrent protection being the major ones. Therefore, it is reasonable to quantify both drawback and benefits of rooftop PV...... LV feeder provided with small scale rooftop PV. Voltage deviation index (VDI) and power loss index (PLI) has been used to quantify the impacts of PV. Furthermore, overvoltage has been taken as an operational constraint to determine maximum penetration level of PV. The analysis has been performed...

  1. Optimal Design of Modern Transformerless PV Inverter Topologies

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during...... the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inverter design variables are derived for each PV inverter topology and installation site. The H5, H6, neutral point...... clamped, active-neutral point clamped and conergy-NPC PV inverters designed using the proposed optimization process feature lower levelized cost of generated electricity and lifetime cost, longer mean time between failures and inject more PV-generated energy into the electric grid than their nonoptimized...

  2. INFLUÊNCIA DA DENSIDADE DE INÓCULO DE Fusarium solani f.sp. phaseoli NA SEVERIDADE DA PODRIDÃO RADICULAR SECA DO FEIJOEIRO EFFECT OF Fusarium solani f.sp. phaseoli INOCULUM DENSITY ON DRY ROOT ROT SEVERITY IN THE COMMON BEAN

    Directory of Open Access Journals (Sweden)

    Gesimária Ribeiro Costa

    2007-09-01

    Full Text Available

    Foram testadas quatro densidades de inóculo de Fusarium solani, em gramas por litro de solo (1,0; 2,0; 4,0 e 8,0 e um tratamento testemunha, em solo tipo Latossolo Vermelho-Escuro, cultivado e não cultivado, com o objetivo de determinar a densidade mínima de inóculo no solo necessária para a ocorrência de podridão radicular seca do feijoeiro. Como variáveis respostas foram avaliadas: número de microorganismos totais do solo, número de propágulos de F. solani, atividade microbiológica total do solo e severidade da doença em plântulas. Os resultados indicaram que a densidade de inóculo do fungo variou com o tipo de solo. Para um solo não cultivado a densidade necessária para causar a doença esteve acima de 5.127 propágulos por grama de solo, enquanto para o solo cultivado a densidade de inóculo para causar doença foi de 3.701 propágulos por grama de solo. Os índices de doença em plântulas cultivadas sob o solo cultivado foram duas vezes superiores ao índice de doença de plântulas sob o solo não cultivado. A atividade microbiológica total nos solos, determinada pela desidrogenase de fluorescina diacetato, não se correlacionou com a população dos microorganismos, indicando que a simples presença desses não implica em que estejam ativos.

    PALAVRAS-CHAVE: Solo supressivo; solo conducivo; Phaseolus vulgaris.

    Four densities of Fusarium solani inoculum (1, 2, 4 and 8 g/L of soil were tested for determining the minimum inoculum density for the occurrence of bean dry root rot, in two soil types. The response variables evaluated were the total number of microorganisms in the soil, the number of F. solani f. sp. phaseoli propagules, total soil microbial activity and seedling disease severity

  3. Development of a dispatchable PV peak shaving system. Final report on PV:BONUS Phase 2 activities

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, W.D. [Conectiv, Inc., Wilmington, DE (United States); Nigro, R.M. [Applied Energy Group, Inc., Hauppauge, NY (United States)

    1999-01-20

    In July 1993, the Delmarva Power and Light Company (now Conectiv, Inc.) was awarded a contract for the development of a Dispatchable Photovoltaic Peak Shaving System under the US Department of Energy PV:BONUS Program. The rationale for the dispatchable PV peak shaving system is based on the coincidence between the solar resource and the electrical load in question. Where poor coincidence exists, a PV array by itself does little to offset peak demands. However, with the addition of a relatively small amount of energy storage, the energy from the PV array can be managed and the value of the PV system increases substantially. In Phase 2, Delmarva Power continued the refinement of the system deployed in Phase 1. Four additional dispatchable PV peak shaving systems were installed for extended testing and evaluation at sites in Delaware, Maryland, Wisconsin and North Carolina. A second type of system that can be used to provide back-up power as well as peak shaving was also developed in Phase 2. This PV-UPS system used a packaging approach nearly identical to the PV peak shaving system, although there were significant differences in the design of the power electronics and control systems. Conceptually, the PV-UPS system builds upon the idea of adding value to PV systems by increasing functionality. A prototype of the PV-UPS system was installed in Delaware for evaluation near the end of the contract period.

  4. Energy balance of the global photovoltaic (PV) industry--is the PV industry a net electricity producer?

    Science.gov (United States)

    Dale, Michael; Benson, Sally M

    2013-04-02

    A combination of declining costs and policy measures motivated by greenhouse gas (GHG) emissions reduction and energy security have driven rapid growth in the global installed capacity of solar photovoltaics (PV). This paper develops a number of unique data sets, namely the following: calculation of distribution of global capacity factor for PV deployment; meta-analysis of energy consumption in PV system manufacture and deployment; and documentation of reduction in energetic costs of PV system production. These data are used as input into a new net energy analysis of the global PV industry, as opposed to device level analysis. In addition, the paper introduces a new concept: a model tracking energetic costs of manufacturing and installing PV systems, including balance of system (BOS) components. The model is used to forecast electrical energy requirements to scale up the PV industry and determine the electricity balance of the global PV industry to 2020. Results suggest that the industry was a net consumer of electricity as recently as 2010. However, there is a >50% that in 2012 the PV industry is a net electricity provider and will "pay back" the electrical energy required for its early growth before 2020. Further reducing energetic costs of PV deployment will enable more rapid growth of the PV industry. There is also great potential to increase the capacity factor of PV deployment. These conclusions have a number of implications for R&D and deployment, including the following: monitoring of the energy embodied within PV systems; designing more efficient and durable systems; and deploying PV systems in locations that will achieve high capacity factors.

  5. An Analysis of Open World PvP in LOTRO's PvMP as a Case Study for PvP Games

    Directory of Open Access Journals (Sweden)

    Toh Weimin

    2014-11-01

    Full Text Available This article focuses on the analysis of emergent gameplay, based on a case study of the author's subjective gameplay experience of Player versus Monster Player (PvMP in The Lord of the Rings Online (LOTRO. The argument presented here is that although there is a core system of Player versus Player (PvP which LOTRO shares with other online games, each type of online game has a specific kind of PvP system which attracts players to engage in the gameplay. For instance, the open world sandbox type of PvP attracts certain players to play in LOTRO's PvMP. One of the main aims of this study is thus to investigate some of the core systems of PvP gameplay in open world sandbox PvP. In this article, LOTRO is shown to offer unique opportunities for studying emergent gameplay in open world games, with particular relevance to PvP studies. Two of the core systems of PvP discussed include the design of the simple gameplay rules to support emergent gameplay, and the community's attitudes towards player's behaviours. The types of emergent gameplay discussed include free play versus negotiated fair play, the players' utilisation of strategies in open world PvP to support collaborative and competitive gameplay, and the changing dynamics of open ended gameplay. It is hoped that the analysis provided in this article would form the­ basis of future work on a more general framework for understanding PvP in other online games.

  6. Numerical study of PV/T-SAHP system

    Institute of Scientific and Technical Information of China (English)

    Gang PEI; Jie JI; Ke-liang LIU; Han-feng HE; Ai-guo JIANG

    2008-01-01

    In order to utilize solar energy effectively and to achieve a higher electrical efficiency by limiting the operating temperature of the photovoltaic (PV) panel, a novel photovoltaic/thermal solar-assisted heat pump (PV/T-SAHP) system was proposed and constructed. The hybrid solar system generates electricity and thermal energy simultaneously. A distributed parameters model of the PV/T-SAHP system was developed and applied to analyze the system dynamic performance in terms of PV action, photothermal action and Rankine cycle processes. The simulation results indicated that the coefficient of performance (COP) of the proposed PV/T-SAHP can be much better than that of the conventional heat pump. Both PV-efficiency and photothermic efficiency have been improved considerably. The results also showed that the performance of this PV/T-SAHP system was strongly influenced by the evaporator area, tube pitch and tilt angle of the PV/T evaporator, which are the key factors in PV/T-SAHP system optimization and PV/T evaporator design.

  7. Parallel experimental study of a novel super-thin thermal absorber based photovoltaic/thermal (PV/T) system against conventional photovoltaic (PV) system

    OpenAIRE

    2015-01-01

    Photovoltaic (PV) semiconductor degrades in performance due to temperature rise. A super thin-conductive thermal absorber is therefore developed to regulate the PV working temperature by retrofitting the existing PV panel into the photovoltaic/thermal (PV/T) panel. This article presented the parallel comparative investigation of the two different systems through both laboratory and field experiments. The laboratory evaluation consisted of one PV panel and one PV/T panel respectively while the...

  8. Integrating Solar PV in Utility System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved

  9. PV solar electricity: status and future

    Science.gov (United States)

    Hoffmann, Winfried

    2006-04-01

    Within the four main market segments of PV solar electricity there are already three areas competitive today. These are off-grid industrial and rural as well as consumer applications. The overall growth within the past 8 years was almost 40 % p.a. with a "normal" growth of about 18 % p.a. for the first three market segments whereas the grid connected market increased with an astonishing 63 % p.a. The different growth rates catapulted the contribution of grid connected systems in relation to the total market from about one quarter 6 years ago towards more than three quarters today. The reason for this development is basically due to industry-politically induced market support programs in the aforementioned countries. It is quite important to outline under which boundary conditions grid connected systems will be competitive without support programs like the feed in tariff system in Germany, Spain and some more to come in Europe as well as investment subsidies in Japan, US and some other countries. It will be shown that in a more and more liberalized utility market worldwide electricity produced by PV solar electricity systems will be able to compete with their generating cost against peak power prices from utilities. The point of time for this competitiveness is mainly determined by the following facts: 1. Price decrease for PV solar electricity systems leading to an equivalent decrease in the generated cost for PV produced kWh. 2. Development of a truly liberalized electricity market. 3. Degree of irradiation between times of peak power demand and delivery of PV electricity. The first topic is discussed using price experience curves. Some explanations will be given to correlate the qualitative number of 20 % price decrease for doubling cumulative worldwide sales derived from the historic price experience curve with a more quantitative analysis based on our EPIA-Roadmap (productivity increase and ongoing improvements for existing technologies as well as development

  10. PV/T slates - Application examples and case studies; PV/T-Schiefer. Anwendungsbeispiele und Fallstudien

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report presents possible applications for PV/T slates based on data from the production atlas presented in another report in this series. Application variants are discussed, including hot-water preparation, air pre-heating, air-water heat pumps, buried seasonal storage and latent seasonal heat storage. Detailed examples are given for a hotel in Lugano, Switzerland and a residential estate in Davos.

  11. PV shading device integrated system in a University Building in Italy

    OpenAIRE

    2004-01-01

    PV Enlargement project PV Enlargement" boldly demonstrates Europe’s commitment for improved energy efficiency and cost-effectiveness of PV systems, enhancing the development of large European PV markets. The project can be subdivided into three major fields of activities: Demonstration (1,218 kWp) of highly cost-effective or very innovative PV technologies in 10 European countries for increasing public awareness about and visibility of PV solar electricity Transfer of PV Technol...

  12. PV technology and success of solar electricity in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Dung, T.Q. [Vietnam National Center for Science and Technology, Ho Chi Minh City (Viet Nam). Solarlab

    1997-12-31

    Since 1990 the PV Technology and the Solar electricity have been strongly developed in Vietnam. The PV experts of Solarlab have studied and set up an appropriate PV Technology responding to local Market needs. It has not only stood well but has been also transferred to Mali Republic and Lao P.D.R. The PV off grid systems of Solarlab demonstrate good efficiency and low prices. Over 60 solar stations and villages have been built to provide solar lighting for about 3000 families along the country in remote, mountainous areas and islands. 400 families are using stand-alone Solar Home Systems. The Solar electricity has been chosen for Rural Electrification and National Telecommunication Network in remote and mountainous regions. Many International projects in cooperation with FONDEM-France, SELF USA and Governmental PV projects have been realized by Solarlab. The experiences of maintenance, management and finance about PV development in Vietnam are also mentioned.

  13. Testing to Support Improvements to PV Components and Systems

    Energy Technology Data Exchange (ETDEWEB)

    THOMAS,H.; KROPOSKI,B.; WITT,C.; BOWER,WARD I.; BONN,RUSSELL H.; GINN,JERRY W.; GONZALEZ,SIGIFREDO

    2000-07-15

    The National Photovoltaic (PV) Program is sponsored by the US Department of Energy and includes a PV Manufacturing Research and Development (R and D) project conducted with industry. This project includes advancements in PV components to improve reliability, reduce costs, and develop integrated PV systems. Participants submit prototypes, pre-production hardware products, and examples of the resulting final products for a range of tests conducted at several national laboratories, independent testing laboratories, and recognized listing agencies. The purpose of this testing is to use the results to assist industry in determining a product's performance and reliability, and to identify areas for potential improvement. This paper briefly describes the PV Manufacturing R and D project, participants in the area of PV systems, balance of systems, and components, and several examples of the different types of product and performance testing used to support and confirm product performance.

  14. PV window - Development and demonstrations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Haugaard, P.

    2011-05-15

    Using the results from the EU project RenewTransnet, which focused on the development of a pane with integrated solar cells, the goal of this project is to develop these principles into a window solution. This window solution is targeted to Danish building tradition and architecture. It is expected that an elegant PV-window solution for both new and retrofit buildings is developed during this project, and which appearance can be customized to each building. Based on results from a related projects carried out by Gaia Solar, the window solution will have the potential of being approximately 30% cheaper than similar products on the market. In this project this price reduction is the objective of the development of a window solution. The project team has succeeded in developing a 2-layer PV-window with glass / glass lamination with EVA as foil, which is 35% cheaper than similar products on the market. Since the price for the frame-profile does not differ significantly at market level, the price comparison is made on the basis of the developed PV-pane. The objective of 30 % price reduction in relation to similar products on the market is met. A special production process to the making glass/glass lamination with EVA as foil has been developed, in which a frame is put around the module which intends both to remove the unwanted tension along the edges, and to prevent the significant spillage of EVA from the module under pressure and prevent the invasive bubbles along the edge of module. Since the developed production method for making glass/glass modules with EVA is simple, a further cost reduction will primarily be in a reduction of the price of the cell. The project process has resulted in the development of a product, which due to continuous restrictions in the building regulations, will be very attractive in future buildings. (LN)

  15. Evaluation of a solar PV tracking prototype on tropic regions

    Directory of Open Access Journals (Sweden)

    Cristian Manuel Agudelo Restrepo

    2016-06-01

    Full Text Available Nowadays climate change is a big concern for human society, due to our high dependence on fossil fuels. A great amount of research effort is focused in solar photovoltaic (PV systems, particularly on the improvement of the conversion efficiency. One technique commonly used is the tracking systems, where the solar PV moves with the sun in order to capture the maximum direct solar radiation. This paper presents a solar PV single-axis tracking system prototype, and a comparison regarding its energy conversion efficiency with a fixed solar PV installation. The system was tested in Fusagasugá, Colombia, which is located in the tropics region.

  16. Solar Energy: Incentives to Promote PV in EU27

    Directory of Open Access Journals (Sweden)

    María del P. Pablo-Romero

    2013-11-01

    Full Text Available The growth in the use of renewable energies in the EU has been remarkable. Among these energies is PV. The average annual growth rate for the EU-27 countries in installed PV capacity in the period 2005-2012 was 41.2%. While the installed capacity of PV has reached almost 82 % of National Renewable Energy Action Plan (NREAP targets for the EU-27 countries for 2020, it is still far from being used at its full potential. Over recent years, several measures have been adopted in the EU to enhance and promote PV. This paper undertakes a complete review of the state of PV power in Europe and the measures taken to date to promote it in EU-27. 25 countries have adopted measures to promote PV. The most widespread measure to promote PV use is Feed- in Tariffs. Tariffs are normally adjusted, in a decreasing manner, annually. Nevertheless, currently, seven countries have decided to accelerate this decrease rate in view of cost reduction of the installations and of higher efficiencies. The second instrument used to promote PV in the EU-27 countries is the concession of subsidies. Nevertheless, subsidies have the disadvantage of being closely linked to budgetary resources and therefore to budgetary constraints. In most EU countries, subsidies for renewable energy for PV are being lowered. Twelve EU-27 countries adopted tax measures. Low-interest loans and green certificate systems were only sparingly used.

  17. PV modules without bypass diodes; PV-Module ohne Bypass-Dioden? - Untersuchungen an einer PV-Fassade

    Energy Technology Data Exchange (ETDEWEB)

    Laukamp, H.; Kresse, A.; Leithold, W. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany)]|[Ingenieurbuero A. Kresse, Karlsruhe (Germany)]|[Solare Systemtechnik GmbH, Freiburg (Germany)

    1998-12-01

    In order to protect solar modules against high output losses with non-homogeneous irradiation, bypass diodes which are mostly accommodated in the module connection socket are used. One would often gladly dispense with these connection sockets for integration of customer-specific large modules in facades. The question: ``Where will the diodes go?`` must then be satisfactorily answered. Both laminating the diodes in the module and their external accommodation cause extra expense elsewhere. It would be ideal if one could dispense with the bypass diodes altogether. This article tries to answer the question, in what conditions this is possible. Starting from the PV facade `Freiburg solar centre`, where one dispensed with the protective diodes, investigations are carried out experimentally and by means of simulation calculations. [Deutsch] Um Solarmodule bei inhomogener Bestrahlung vor hohen Verlustleistungen zu schuetzen, werden ueblicherweise Bypass-Dioden eingesetzt, die zumeist in der Modulanschlussdose untergebracht sind. Zur Fassadenintegration von kundenspezifischen Grossmodulen wuerde man manchmal gerne auf die Anschlussdosen verzichten. Hierfuer muesste zunaechst die Frage `wohin mit den Dioden?` befriedigend beantwortet werden. Sowohl die Einlaminierung der Dioden in das Modul, als auch deren externe Unterbringung versursachen an anderer Stelle einen erhoehten Aufwand. Ideal waere es, wenn man auf die Bypass-Dioden ganz verzichten koennte. Die vorliegende Arbeit versucht die Frage zu beantworten, unter welchen Bedingungen dies moeglich ist. Ausgehend von der PV-Fassade `Solarzentrum Freiburg` - hier wurde auf den Einsatz von Schutzdioden verzichtet - werden experimentell und mittels Simulationsrechnungen Untersuchungen durchgefuehrt. (orig./RHM)

  18. A minimum achievable PV electrical generating cost

    Energy Technology Data Exchange (ETDEWEB)

    Sabisky, E.S. [11 Carnation Place, Lawrenceville, NJ 08648 (United States)

    1996-03-22

    The role and share of photovoltaic (PV) generated electricity in our nation`s future energy arsenal is primarily dependent on its future production cost. This paper provides a framework for obtaining a minimum achievable electrical generating cost (a lower bound) for fixed, flat-plate photovoltaic systems. A cost of 2.8 $cent/kWh (1990$) was derived for a plant located in Southwestern USA sunshine using a cost of money of 8%. In addition, a value of 22 $cent/Wp (1990$) was estimated as a minimum module manufacturing cost/price

  19. Integrating Solar PV in Utility System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved

  20. Simulation of Power Produced by a Building Added PV System in Indonesia using virtual reality

    NARCIS (Netherlands)

    Veldhuis, A.J.; Reinders, A.H.M.E.

    2014-01-01

    In this study a PV system will be simulated using virtual reality software for PV system simulations -called VR4PV - to show the effectiveness of the modelling of PV systems on buildings which are placed in the tropics. The PV system used for this study has been installed in Papua, Indonesia and inc

  1. Development of a Dispatchable PV Peak Shainv System. PV: Bonus Program - Phase 1 Report. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1995-10-01

    This report summarizes the work performed by Delmarva Power and Light and its subcontractors in Phase 1 of the US Department of Energy's PV:BONUS Program. The purpose of the program is to develop products and systems for buildings which utilize photovoltaic (N) technology. Beginning with a cooperative research effort with the University of Delaware's Center for Energy and Environmental Policy Research Delmarva Power developed and demonstrated the concept of Dispatchable PV Peak Shaving. This concept and the system which resulted horn the development work are unique from other grid-connected PV systems because it combines a PV, battery energy storage, power conversion and control technologies into an integrated package. Phase 1 began in July 1993 with the installation of a test and demonstration system at Delmarva's Northern Division General Office building near Newark, Delaware. Following initial testing throughout the summer and fall of 1993, significant modifications were made under an amendment to the DOE contract. Work on Phase 1 concluded in the early spring of 1995. Significant progress towards the goal of commercializing the system was made during Phase 1, and is summarized. Based on progress in Phase 1, a proposal to continue the work in Phase 2 was submitted to the US DOE in May 1995. A contract amendment and providing funds for the Phase 2 work is expected in July 1995.

  2. Experimental investigation of PV modules recycling; PV module recycle no jikkenteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Unagida, H.; Kurokawa, K. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Sakuta, K.; Otani, K.; Murata, K. [Electrotechnical Laboratory, Tsukuba (Japan)

    1997-11-25

    Recycling, cost/energy analysis and recovery experiment were made on crystalline silicon PV modules with EVA(ethylene vinyl acetate)-laminated structure. The life of modules is dependent not on performance deterioration of PV cells themselves but on yellowing or poor transmittance of EVA caused by ultraviolet ray, and disconnection between cells by thermal stress. Recovery is carried out in 3 stages of cell, wafer and material. Recovery in the stages of cell and wafer results in considerable reduction of energy and cost. The recovery experiment was carried out using PV module samples prepared by cutting the modules into 25times15mm pieces after removing Al frames from the used modules, peeling back sheets and cutting off EVA. Since a nitric acid process at 70-80degC can dissolve EVA effectively, it is promising for reuse of surface glass and PV cells as they are. This process is also carried out under a condition around room temperature and pressure, contributing to cost reduction and energy saving for recycling. Generation of harmful NOx is only a problem to be solved. 2 refs., 6 figs., 1 tab.

  3. Projecting of PV facades in consideration of PV-specific operating conditions; Besonderheiten bei der Projektierung von Photovoltaik-Fassadenanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Decker, B.; Grimmig, B.; Mencke, D. [Institut fuer Solarenergieforschung GmbH Hameln/Emmerthal (ISFH), Emmerthal (Germany). Gruppe Photovoltaik-Systeme; Stellbogen, D. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany). Fachgebiet Photovoltaische Anlagentechnik

    1998-02-01

    PV facades can provide several additional functions such as weather protection, thermal insulation, daylighting or sun protection. On the other hand, specific operating conditions for PV facades must be taken into account when selecting components and designing the system. Depending on ventilation conditions, there is a large range of maximum module temperatures. South-oriented PV facades receive about 30% less yearly irradiation than an optimally inclined PV generator, hence reflection losses are approximately 4% higher. The maximum of yearly irradiation lies only in the 400-600 W/m{sup 2} range. Surrounding buildings and/or vegetation can impair performance of the PV-facades. For a south-oriented PV facade an annual yield in the range of 470-560 kwh/kW{sub p}.a has been prodicted which was verified by operating results of eight PV facades. (orig.) [Deutsch] Photovoltaik (PV) Fassaden ermoeglichen neben der Stromerzeugung zusaetzliche Funktionen wie Wetterschutz bzw. Waermedaemmung des Gebaeudes oder Tageslichtnutzung bzw. Sonnenschutz der Innenraeume. Allerdings muessen fassadenspezifische Betriebsbedingungen, bei der Komponentenauswahl und Systemauslegung beruecksichtigt werden. Unterschiedliche Hinterlueftungsbedingungen fuehren zu einer grossen Bandbreite der maximalen Modultemperatur. PV-Suedfassaden empfangen etwa 30% weniger Jahreseinstrahlung als ein optimal geneigter PV-Generator. Die Haelfte der jaehrlichen Einstrahlung trifft mit Einfallswinkeln groesser 50 auf die vertikal angeordneten Module wodurch die Reflexionsverluste um ca. 4% hoeher sind. Das Maximum der Jahreseinstrahlung liegt nur um 400-600 W/m{sup 2} und erreicht selten Werte ueber 800 W/m{sup 2}. Umliegende Gebaeude oder Vegetation koennen zu Teilabschattungen des Generators fuehren. Fuer eine vertikale PV-Suedfassade wird ein Jahresenergieertrag in Hoehe von 470-560 kWh/kW{sub p}.a prognostiziert, der anhand der Betriebsergebnisse von acht PV-Fassadenanlagen verifiziert werden konnte

  4. Host Range and Seed Transmission of Xanthomonas axonopodis pv.cyamopsidis in Guar%瓜尔豆细菌性疫病种子带菌检测及寄主范围测定

    Institute of Scientific and Technical Information of China (English)

    任毓忠; 杨江平; 李腾宇; 王磊; 刘林; 王华兵

    2015-01-01

    瓜尔豆细菌性疫病是新疆新发现的一种病害,本文对4份瓜尔豆种子根据症状分为无症状型(占总调查种子数36.55%)、中间型(占总调查种子数51.94%)和严重变色型(占总调查种子数11.51%)三类,不同类型种子的室内发芽率、带菌率和出苗率存在明显差异,严重变色型种子发芽率最低,为31.11%;中间型和无症状型种子的发芽率相对较高,分别为87.78%和63.33%;在室内培养基上进行种子带菌率检测,结果表明,严重变色型种子的带菌率最高,为51.11%,中间型和无症状型的带菌率为31.11%和24.44%.在水琼脂上严重变色型种子的出苗率为42.00%;无症状种子和中间型的出苗率分别为71.67%和90.00%.盆栽幼苗出苗和发病实验结果显示,无症状种子的出苗率为83.33%,而严重变色种子的出苗率仅为40.00%;不同类型种子的带菌率存在明显差异,无症状种子的带菌率为59.18%,而严重变色种子的带菌率为84.38%,远高山无症状种子的发病率;表明种子严重变色(或带菌率较高)都会严重影响种子的质量,继而造成种子发芽率和田间出苗率的降低.人工接种寄主范围测定结果显示,瓜尔豆细菌性疫病还可以感染、大豆(Glycine max)、豇豆(Vigna unguiculata)、绿豆(Vigna radiata)和芸豆(Phaseolus coccineus L.var.albonanus Baile)等豆科作物.

  5. Sensitivity Analysis of qPCR in Detecting the Xanthomonas axonopodis pv.citri%利用qPCR技术检测柑橘溃疡病菌的灵敏度分析

    Institute of Scientific and Technical Information of China (English)

    李文娟; 肖翠; 戴素明; 李大志; 邓子牛

    2015-01-01

    以常规PCR为对照,分析了实时荧光定量PCR (qPCR)检测柑橘溃疡病菌DNA和柑橘溃疡病菌菌量的灵敏度,并对接种柑橘溃疡病菌后的冰糖橙样品进行了动态监测.结果显示,qPCR检测柑橘溃疡病菌DNA和柑橘溃疡病菌菌量的灵敏度比常规PCR高l~3个数量级,且常规PCR对柑橘溃疡病菌DNA的检测会受到寄主植物DNA的干扰,qPCR不受寄主植物DNA影响;对接种后冰糖橙样品的分析,qPCR即时就能检测到柑橘溃疡病菌,并能实时观察到柑橘溃疡病菌在寄主叶片的增殖情况,而常规PCR要接种后2d才能检测到柑橘溃疡病菌.

  6. Análisis de ADNC-AFLP para la expresión diferencial de genes en la interacción Manihot esculenta Grantz (Yuca Xanthomonas axonopodis pv. Manihotis

    Directory of Open Access Journals (Sweden)

    Verdier V.

    2001-06-01

    Full Text Available Desarrollar patrones ADNc - AFLP, para identificar fragmentos expresados diferencialmente entre dos variedades de yuca, una resistente y una susceptible a la bacteriosis. Aislar, secuenciar y analizar los fragmentos seleccionados. Corroborar la expresión diferencial de estos fragmentos mediante "northern blots".

  7. Oxynitride Thin Film Barriers for PV Packaging

    Energy Technology Data Exchange (ETDEWEB)

    Glick, S. H.; delCueto, J. A.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2005-11-01

    Dielectric thin-film barrier and adhesion-promoting layers consisting of silicon oxynitride materials (SiOxNy, with various stoichiometry) were investigated. For process development, films were applied to glass (TCO, conductive SnO2:F; or soda-lime), polymer (PET, polyethylene terephthalate), aluminized soda-lime glass, or PV cell (a-Si, CIGS) substrates. Design strategy employed de-minimus hazard criteria to facilitate industrial adoption and reduce implementation costs for PV manufacturers or suppliers. A restricted process window was explored using dilute compressed gases (3% silane, 14% nitrous oxide, 23% oxygen) in nitrogen (or former mixtures, and 11.45% oxygen mix in helium and/or 99.999% helium dilution) with a worst-case flammable and non-corrosive hazard classification. Method employed low radio frequency (RF) power, less than or equal to 3 milliwatts per cm2, and low substrate temperatures, less than or equal to 100 deg C, over deposition areas less than or equal to 1000 cm2. Select material properties for barrier film thickness (profilometer), composition (XPS/FTIR), optical (refractive index, %T and %R), mechanical peel strength and WVTR barrier performance are presented.

  8. 水稻白叶枯病菌对拌种灵抗药性分子机制研究%Molecular Mechanism of Amicarthiazol Resistance in Xanthomonas oryzae pv.oryzae

    Institute of Scientific and Technical Information of China (English)

    张宇君; 李俊; 赵伟; 周明国

    2005-01-01

    通过紫外诱变获得了抗拌种灵水稻白叶枯病菌(Xanthomonas oryzae pv.oryzae)的突变体,这些突变体可以在含100 μg·ml-1拌种灵平板上生长,而敏感菌株在10 μg·ml-1浓度下则不能生长.敏感菌株琥珀酸脱氢酶活性受拌种灵强烈抑制,而抗药突变体的酶活性较低,且不受药剂抑制.应用6对引物,从水稻白叶枯病菌野生敏感菌株和室内诱导抗药性菌株中扩增到琥珀酸脱氢酶基因全序列.该基因全长3 616 bp,编码1 115个氨基酸,含有2个内含子.与柑橘溃疡病菌(Xanthomonas axonopodis pv. citri)琥珀酸脱氢酶核苷酸同源性93%,氨基酸同源性97%;与其它6种病原细菌琥珀酸脱氢酶基因编码的氨基酸序列同源性为43%~95%.敏感菌株和抗药菌株的琥珀酸脱氢酶序列分析表明,琥珀酸脱氢酶铁硫蛋白亚基中229位氨基酸由组氨酸(CAC)突变为酪氨酸(TAC)是导致X. oryzae对拌种灵产生抗药性的主要原因.

  9. National survey report on PV power applications in Switzerland 2006

    Energy Technology Data Exchange (ETDEWEB)

    Huesser, P. [Nova Energie GmbH, Aarau (Switzerland); Hostettler, T. [Ingenieurbuero Hostettler, Berne (Switzerland)

    2007-07-01

    This annual report was published by the Swiss Federal Office of Energy (SFOE) as part of the International Energy Agency's work on the exchange and dissemination of information on photovoltaic power systems (PVPS). The political situation in Switzerland with regard to the promotion of photovoltaics (PV) and new legislation in the energy area is discussed. The report provides information on installed PV power, costs and prices and the Swiss PV industry. Examples of PV applications are presented and data on the cumulative installed PV power in various application sectors is presented and discussed. Highlights, major projects and various demonstration and field-test programmes are dealt with, as are public budgets for market stimulation. Figures on the development, production and prices of PV cells and modules are presented. Swiss balance-of-system products are reviewed, as are PV-related services and the value of the Swiss PV business. A review of non-technical factors and new initiatives completes the report.

  10. Development of PV powered consumer products using future scenarios

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Meulen, van der B.J.R.; Eger, A.O.

    2006-01-01

    Given the high potential of PV technology to reduce the environmental impact of electricity use of consumer products, it would be worthwhile to advance the application of PV systems in mass produced products. To date this field of application has been explored only to a limited extent. For this reas

  11. PV O&M Cost Model and Cost Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Andy

    2017-03-15

    This is a presentation on PV O&M cost model and cost reduction for the annual Photovoltaic Reliability Workshop (2017), covering estimating PV O&M costs, polynomial expansion, and implementation of Net Present Value (NPV) and reserve account in cost models.

  12. Applications of ``PV Optics`` for solar cell and module design

    Energy Technology Data Exchange (ETDEWEB)

    Sopori, B.L.; Madjdpour, J.; Chen, W. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    This paper describes some applications of a new optics software package, PV Optics, developed for the optical design of solar cells and modules. PV Optics is suitable for the analysis and design of both thick and thin solar cells. It also includes a feature for calculation of metallic losses related to contacts and back reflectors.

  13. Comparative assessment of PV plant performance models considering climate effects

    DEFF Research Database (Denmark)

    Tina, Giuseppe; Ventura, Cristina; Sera, Dezso

    2017-01-01

    The paper investigates the effect of climate conditions on the accuracy of PV system performance models (physical and interpolation methods) which are used within a monitoring system as a reference for the power produced by a PV system to detect inefficient or faulty operating conditions. The met...

  14. Product integrated PV: the future is design and styling

    NARCIS (Netherlands)

    Eggink, Wouter; Reinders, Angèle

    2016-01-01

    In this paper we explore how PV powered products have been designed in the past. For this purpose we have drawn a historical time line of the design features of PV powered products in the context of main stream design and styling. Our time frame is 1970 till 2016, focusing in first instance on consu

  15. Analysis of Long-Term Performance of PV Systems

    NARCIS (Netherlands)

    Nordmann, T.; Clavadetscher, L.; van Sark, Wilfried; Green, M.

    2015-01-01

    This report describes the activities, conclusions and continued efforts undertaken in Subtask 1 by the participating countries in IEA-PVPS Task 13. Subtask 1 examines the PV power plant as a system. It collects and studies the data supplied from installed operating PV plants from different countries

  16. Energy requirements and CO2 mitigation potential of PV systems

    NARCIS (Netherlands)

    Alsema, E.A.

    2006-01-01

    In this paper we investigate the energy requirements of PV modules and systems and calculate the Energy Pay-Back Time for two major PV applications. Based on a review of past energy analysis studies we explain the main sources of differences and establish a "best estimate" for key system components.

  17. Costs of Residential Solar PV Plants in Distribution Grid Networks

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Yang, Guangya; Ipsen, Hans Henrik

    2015-01-01

    In this article we investigate the impact of residential solar PV plants on energy losses in distribution networks and their impact on distribution transformers lifetime. Current guidelines in Denmark states that distribution transformers should not be loaded with more than 67% solar PV power...... called “Availability Tariff”. According to the Danish Energy Regulatory Authority, the Availability Tariff must cover the exact expenses, with energy savings etc. from the solar PV plants taken into consideration. Our conclusion is that a distribution network, which represents a typical residential...... to avoid accelerated loss of life. If a solar PV plant causes this limit to be exceeded, the particular owner has to pay for upgrading the transformer. Distribution Network Operators also charge an annual tariff from the solar PV plants to cover the expenses to keep the grid capacity available, the so...

  18. Codes, standards, and PV power systems. A 1996 status report

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, J

    1996-06-01

    As photovoltaic (PV) electrical power systems gain increasing acceptance for both off-grid and utility-interactive applications, the safety, durability, and performance of these systems gains in importance. Local and state jurisdictions in many areas of the country require that all electrical power systems be installed in compliance with the requirements of the National Electrical Code{reg_sign} (NEC{reg_sign}). Utilities and governmental agencies are now requiring that PV installations and components also meet a number of Institute of Electrical and Electronic Engineers (IEEE) standards. PV installers are working more closely with licensed electricians and electrical contractors who are familiar with existing local codes and installation practices. PV manufacturers, utilities, balance of systems manufacturers, and standards representatives have come together to address safety and code related issues for future PV installations. This paper addresses why compliance with the accepted codes and standards is needed and how it is being achieved.

  19. A global strategy for the European PV industry

    Energy Technology Data Exchange (ETDEWEB)

    Viaud, M.; Despotou, E.; Latour, M. [European Photovoltaic Industry Association (EPIA) secretariat, Brussels (Belgium); Hoffmann, W.; Macias, E.; Cameron, M.; Laborde, E. [European Photovoltaic Industry Association (EPIA), Brussels (Belgium)

    2004-07-01

    The objective was to develop a comprehensive strategy that answers to the need of today European PV industry. Namely: - Develop PV markets in Europe - Develop export markets. - Position the European PV industry within the European political environment and support the effort of national actors in their local objectives. This method lends itself to brainstorming to create actions and synergies, on order to achieve strategy objectives. The whole work is based on working groups clearly defined on the purpose, where all EPIA members are invited to participate. The overall first results are presented during the 19. EU PV Conference in Paris and EPIA will do recommendations on actions to be undertaken in the future. This strategy is co-financed by EPIA members and the 6. Framework Programme for research of the European Commission through the PV Catapult project. (authors)

  20. Overview of Recent Grid Codes for PV Power Integration

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso;

    2012-01-01

    and Distribution System Operators (DSOs) had to keep the safety and reliability of the network under strict rules and regulations. The aim of the paper is to realize a survey of recent Grid Codes (GC) and regulations for grid connected PV systems. The focus is on grid interface requirements, power quality concerns...... and Anti-Islanding (AI) issues regarding PV systems connected to low voltage (LV) and medium voltage (MV) levels of the network.......The challenge to bring down the cost of produced photovoltaic (PV) power had a major impact on the PV market and in consequence the grid operators experienced higher and higher PV power penetration. The growing share of this decentralized generation plants started to affect the grid stability...

  1. Fire hazard and other safety concerns of PV systems

    Science.gov (United States)

    Dhere, Neelkanth G.

    2011-09-01

    Photovoltaic modules are usually considered safe and reliable. But in case of grid-connected PV systems that are becoming very popular, the issue of fire safety of PV modules is becoming increasingly important due to the employed high voltages of 600 V to 1000 V. The two main factors i.e. open circuiting of the bypass diode and ground fault that are responsible for the fire in the PV systems have been discussed in detail along with numerous real life examples. Recommendations are provided for preventing the fire hazards such as having at least class C fire rated PV modules, proper bypass and blocking diodes and interestingly, having an ungrounded PV system.

  2. Optimum Design Of On Grid Pv System Using Tracking System

    Directory of Open Access Journals (Sweden)

    Saeed Mansour

    2015-05-01

    Full Text Available Abstract The fossil fuel is a main issue in the world due to the increase of fossil fuel cost and the depletion of the fossil fuel with continuous increasing demand on electricity. With continuous decrease of PV panels cost it is interesting to consider generation of electricity from PV system. To provide electric energy to a load in a remote area where electric grid utility is not available or connection with grid utility is available there are two approaches of photovoltaic system PV without tracking system Fixed System and PV with tracking systems. The result shows that the energy production by using PV with tracking system generates more energy in comparison with fixed panels system. However the cost per produced KWH is less in case of using fixed panels. This is the backbone in choice between two approaches of photovoltaic system. In this work a system design and cost analysis for two approaches of photovoltaic system are considered.

  3. Physical Effects of Distributed PV Generation on California's Distribution System

    CERN Document Server

    Cohen, Michael A

    2015-01-01

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  4. PV Performance Modeling Methods and Practices: Results from the 4th PV Performance Modeling Collaborative Workshop.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    In 2014, the IEA PVPS Task 13 added the PVPMC as a formal activity to its technical work plan for 2014-2017. The goal of this activity is to expand the reach of the PVPMC to a broader international audience and help to reduce PV performance modeling uncertainties worldwide. One of the main deliverables of this activity is to host one or more PVPMC workshops outside the US to foster more international participation within this collaborative group. This report reviews the results of the first in a series of these joint IEA PVPS Task 13/PVPMC workshops. The 4th PV Performance Modeling Collaborative Workshop was held in Cologne, Germany at the headquarters of TÜV Rheinland on October 22-23, 2015.

  5. Innovations in Wind and Solar PV Financing

    Energy Technology Data Exchange (ETDEWEB)

    Cory, K.; Coughlin, J.; Jenkin, T.; Pater, J.; Swezey, B.

    2008-02-01

    There is growing national interest in renewable energy development based on the economic, environmental, and security benefits that these resources provide. Historically, greater development of our domestic renewable energy resources has faced a number of hurdles, primarily related to cost, regulation, and financing. With the recent sustained increase in the costs and associated volatility of fossil fuels, the economics of renewable energy technologies have become increasingly attractive to investors, both large and small. As a result, new entrants are investing in renewable energy and new business models are emerging. This study surveys some of the current issues related to wind and solar photovoltaic (PV) energy project financing in the electric power industry, and identifies both barriers to and opportunities for increased investment.

  6. Fidelity Susceptibility as Holographic PV criticality

    CERN Document Server

    Momeni, Davood; Myrzakulov, Ratbay

    2016-01-01

    Motivated by the fact that the quantum entanglement entropy is dual to an area in AdS, quantities dual to a volume in the AdS have also been recently proposed. These include the holographic complexity and fidelity susceptibility of a quantum system. Even though both of them are dual to an volume in the bulk, there are some interesting difference between them. In this letter, we will explicitly compare them for an $ AdS _4$ solution, and clarify the main differences between them from thermodynamic point of the view. We will also obtain the correct and appropriate holographic dual of the thermodynamic volume of AdS blackhole, and demonstrate that to explain therodynamic in extended phase PV picture, from the AdS/CFT point of view,fidelity susceptibility is the preferred quantity in comparison to holographic complexity.

  7. Valley of Death analysis for polymer PV technology; Valley of Death analyse voor polymere PV technologie

    Energy Technology Data Exchange (ETDEWEB)

    Schoots, K. [ECN Beleidsstudies, Petten (Netherlands)

    2013-12-15

    This report describes the results of a qualitative study of the barriers that actors involved in the development and commercialization of polymer solar cells, may encounter. The purpose of this socio-economic research is to identify these barriers for the (market) development of thin film polymeric PV technology and to develop strategies for them in order to overcome the constraints. The necessary data are collected from interviews with actors who are active in the development and deployment of conventional solar cells. Based on the results from this study, it is conclude that it is important for the Organic PV industry to carry out many market experiments beyond the built environment. The report provides recommendations with regard to the markets in which these experiments are most likely to succeed and which drivers should be taken into account [Dutch] Dit rapport beschrijft de resultaten van een kwalitatief onderzoek naar de barrieres die actoren, betrokken bij de ontwikkeling en marktintroductie van polymere zonnecellen, kunnen tegenkomen. Het doel van dit sociaal-economische onderzoek is deze barrieres voor de (markt)ontwikkeling van dunne film polymere PV technologie te identificeren en strategieen te ontwikkelen om ze voor te zijn of ze te overbruggen. De benodigde gegevens worden verzameld uit interviews met actoren die actief zijn in de ontwikkeling en uitrol van conventionele zonnecellen. Op basis van de resultaten uit dit onderzoek komen we tot de conclusie dat het voor de Organische PV sector belangrijk is veel marktexperimenten aan te gaan buiten de gebouwde omgeving. Het rapport geeft aanbevelingen in welke soort markten deze experimenten de meeste kans van slagen hebben en met welke drivers van marktpartijen rekening moet worden gehouden.

  8. Managing PV Power on Mars - MER Rovers

    Science.gov (United States)

    Stella, Paul M.; Chin, Keith; Wood, Eric; Herman, Jennifer; Ewell, Richard

    2009-01-01

    The MER Rovers have recently completed over 5 years of operation! This is a remarkable demonstration of the capabilities of PV power on the Martian surface. The extended mission required the development of an efficient process to predict the power available to the rovers on a day-to-day basis. The performance of the MER solar arrays is quite unlike that of any other Space array and perhaps more akin to Terrestrial PV operation, although even severe by that comparison. The impact of unpredictable factors, such as atmospheric conditions and dust accumulation (and removal) on the panels limits the accurate prediction of array power to short time spans. Based on the above, it is clear that long term power predictions are not sufficiently accurate to allow for detailed long term planning. Instead, the power assessment is essentially a daily activity, effectively resetting the boundary points for the overall predictive power model. A typical analysis begins with the importing of the telemetry from each rover's previous day's power subsystem activities. This includes the array power generated, battery state-of-charge, rover power loads, and rover orientation, all as functions of time. The predicted performance for that day is compared to the actual performance to identify the extent of any differences. The model is then corrected for these changes. Details of JPL's MER power analysis procedure are presented, including the description of steps needed to provide the final prediction for the mission planners. A dust cleaning event of the solar array is also highlighted to illustrate the impact of Martian weather on solar array performance

  9. Sub-synchronous resonance damping using high penetration PV plant

    Science.gov (United States)

    Khayyatzadeh, M.; Kazemzadeh, R.

    2017-02-01

    The growing need to the clean and renewable energy has led to the fast development of transmission voltage-level photovoltaic (PV) plants all over the world. These large scale PV plants are going to be connected to power systems and one of the important subjects that should be investigated is the impact of these plants on the power system stability. Can large scale PV plants help to damp sub-synchronous resonance (SSR) and how? In this paper, this capability of a large scale PV plant is investigated. The IEEE Second Benchmark Model aggregated with a PV plant is utilized as the case study. A Wide Area Measurement System (WAMS) based conventional damping controller is designed and added to the main control loop of PV plant in order to damp the SSR and also investigation of the destructive effect of time delay in remote feedback signal. A new optimization algorithm called teaching-learning-based-optimization (TLBO) algorithm has been used for managing the optimization problems. Fast Furrier Transformer (FFT) analysis and also transient simulations of detailed nonlinear system are considered to investigate the performance of the controller. Robustness of the proposed system has been analyzed by facing the system with disturbances leading to significant changes in generator and power system operating point, fault duration time and PV plant generated power. All the simulations are carried out in MATLAB/SIMULINK environment.

  10. Kauai Island Utility Co-op (KIUC) PV integration study.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Mousseau, Tom (Knoxville, TN)

    2011-08-01

    This report investigates the effects that increased distributed photovoltaic (PV) generation would have on the Kauai Island Utility Co-op (KIUC) system operating requirements. The study focused on determining reserve requirements needed to mitigate the impact of PV variability on system frequency, and the impact on operating costs. Scenarios of 5-MW, 10-MW, and 15-MW nameplate capacity of PV generation plants distributed across the Kauai Island were considered in this study. The analysis required synthesis of the PV solar resource data and modeling of the KIUC system inertia. Based on the results, some findings and conclusions could be drawn, including that the selection of units identified as marginal resources that are used for load following will change; PV penetration will displace energy generated by existing conventional units, thus reducing overall fuel consumption; PV penetration at any deployment level is not likely to reduce system peak load; and increasing PV penetration has little effect on load-following reserves. The study was performed by EnerNex under contract from Sandia National Laboratories with cooperation from KIUC.

  11. Three junction holographic micro-scale PV system

    Science.gov (United States)

    Wu, Yuechen; Vorndran, Shelby; Ayala Pelaez, Silvana; Kostuk, Raymond K.

    2016-09-01

    In this work a spectrum splitting micro-scale concentrating PV system is evaluated to increase the conversion efficiency of flat panel PV systems. In this approach, the dispersed spectrum splitting concentration systems is scaled down to a small size and structured in an array. The spectrum splitting configuration allows the use of separate single bandgap PV cells that increase spectral overlap with the incident solar spectrum. This results in an overall increase in the spectral conversion efficiency of the resulting system. In addition other benefits of the micro-scale PV system are retained such reduced PV cell material requirements, more versatile interconnect configurations, and lower heat rejection requirements that can lead to a lower cost system. The system proposed in this work consists of two cascaded off-axis holograms in combination with a micro lens array, and three types of PV cells. An aspherical lens design is made to minimize the dispersion so that higher concentration ratios can be achieved for a three-junction system. An analysis methodology is also developed to determine the optical efficiency of the resulting system, the characteristics of the dispersed spectrum, and the overall system conversion efficiency for a combination of three types of PV cells.

  12. PV Project Finance in the United States, 2016

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, David; Lowder, Travis; Schwabe, Paul

    2016-09-01

    This brief is a compilation of data points and market insights that reflect the state of the project finance market for solar photovoltaic (PV) assets in the United States as of the third quarter of 2016. This information can generally be used as a simplified benchmark of the costs associated with securing financing for solar PV as well as the cost of the financing itself (i.e., the cost of capital). Three sources of capital are considered -- tax equity, sponsor equity, and debt -- across three segments of the PV marketplace.

  13. PV Validation and Bankability Workshop: San Jose, California

    Energy Technology Data Exchange (ETDEWEB)

    Granata, J.; Howard, J.

    2011-12-01

    This report is a collaboration between Sandia National Laboratories, the National Renewable Energy Laboratory, and the Florida Solar Energy Center (FSEC). The report provides feedback from the U.S. Department of Energy's (DOE) Solar Program PV Validation and Bankability Workshop in San Jose, California on August 31, 2011. It focuses on the current state of PV in the United States, private funding to fund U.S. PV industry growth, roles and functions of the regional test center program, and ways to improve the current validation and bankability practices.

  14. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu;

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module’s...... impedance spectrum, and further construct an impedance model that can link environmental changes to the model’s parameters. To achieve this, an optimized setup has been developed for long-term impedance spectra monitoring synchronised with accurate irradiance and temperature data. Preliminary results show...

  15. Monitoring and Analysis of Two Grid Connected PV Systems

    OpenAIRE

    2013-01-01

    International audience; In this paper, two grid connected photovoltaic systems are studied and monitored for fault detection ad predictive reliability. The first PV grid, is at CNRS-PROMES laboratory in Perpignan, built in 2001 with 3 PV arrays named "Shed","Brise soleil","Mur rideau") connected to the grid thanks to many inverter of different power (3 of 4KWC and 2 of 2.5KWC). The second one is at CNRS-LAAS in Toulouse with a power of 100kWc. It is composed of a facade of 36kWc PV array and ...

  16. CPV Vs. PV from a grid-matching perspective

    Science.gov (United States)

    Strobach, E.; Bader, S.; Faiman, D.; Solomon, A. A.; Meron, G.

    2012-10-01

    In a recently-published series of papers we studied the general problem of matching large PV systems of various kinds to the electricity grid. In those studies CPV systems were simulated via an artificial ansatz in which they were treated as 2-axis flat-panel PV systems whose light sensitivity is only to the direct normal component (DNI) of solar irradiance. The present study replaces this ansatz with an experimentally validated model of a real CPV system. We compare a genuine 2-axis high-concentration CPV system with a static flat-panel PV system from the standpoint of matching both system types to the Israeli electricity grid.

  17. Design of a Solar Tracker System for PV Power Plants

    Directory of Open Access Journals (Sweden)

    Tiberiu Tudorache

    2010-04-01

    Full Text Available This paper deals with the design and execution of a solar tracker systemdedicated to the PV conversion panels. The proposed single axis solar tracker deviceensures the optimization of the conversion of solar energy into electricity by properlyorienting the PV panel in accordance with the real position of the sun. The operation of theexperimental model of the device is based on a DC motor intelligently controlled by adedicated drive unit that moves a mini PV panel according to the signals received from twosimple but efficient light sensors. The performance and characteristics of the solar trackerare experimentally analyzed.

  18. Angle Resolved Performance Measurements on PV Glass and Modules

    DEFF Research Database (Denmark)

    Juutilainen, Line Tollund; Thorsteinsson, Sune; Poulsen, Peter Behrensdorff

    2016-01-01

    The angular response of PV-modules has significant impact on the energy production. This is especially pronounced in BIPV where installation angles often are far from optimal. Nevertheless, a gain in energy yield may be obtained by choosing a proper glass as superstrate. In this work we present...... the concept of PV balconies as cost efficient and easy way of integrating PV into buildings. The experimental work consists of the fabrication of single cell mini modules with different glass covering, and characterizing their angular response in a custom made setup, where only the direct sunlight is used...

  19. Measures for diffusion of solar PV in selected African countries

    DEFF Research Database (Denmark)

    Nygaard, Ivan; Hansen, Ulrich Elmer; Mackenzie, Gordon A.;

    2015-01-01

    This paper investigates how African governments are considering supporting and promoting the diffusion of solar PV. This issue is explored by examining so-called ‘technology action plans (TAPs)’, which were main outputs of the Technology Needs Assessment project implemented in 10 African countries...... that governments’ strategies to promoting solar PV are moving from isolated projects towards frameworks for market development and that there are high expectations to upgrading in the PV value chain through local assembly of panels and local production of other system elements. Commonly identified measures include...... support to: local production; financing schemes; tax exemptions; establishment and reinforcement of standards; technical training; and research and development....

  20. A comparison of design features of 80 pv-powered products

    NARCIS (Netherlands)

    Apostolou, G.; Reinders, A.H.M.E.

    2012-01-01

    In this paper 80 commercially available PV products have been analysed. The data set comprises 46 low power PV products in the range of 0 to 17 Wp and 34 PV products with a power of 17 Wp up to 27 kWp. The goal of our study is to investigate and evaluate features of PV products that are available on

  1. Design Considerations for Stand-Alone Photovoltaic (PV Cell Applications

    Directory of Open Access Journals (Sweden)

    Mehmet Cebeci

    2013-06-01

    Full Text Available Solar energy is one of the most important renewable energy sources. The photovoltaic (PV cell systems are used to convert solar energy into electricity. PV systems are divided into two as fixed systems and tracking systems. Fixed systems are mounted at a certain tilt with horizontal to make full use of sunlight. The tilt angle of PV arrays in a fixed system depends on the location and time. If this tilt angle is determined well, the amount of insolation and the energy that is generated increases. When a stand-alone PV cell system is being chosen, certain design operations should be implemented. The number of modules and batteries needed for any system should be calculated by means of the amount of load, insolation level, module characteristics, etc. The design of system is finalized according to the energy demand.

  2. Retaining the Value of PV at High Penetration Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah; Bolen, Michael

    2016-10-13

    PV prices have dropped and are now attractive without incentives for peaking applications in some locations. Modeling suggests and, empirically, some regions demonstrate that as PV penetration increases its value decreases, predominantly due to a decrease in energy and capacity value. It is not apparent what technologies and price may be needed for PV to supply tens of percent of electricity in the most economically efficient manner. A 1-day workshop was co-sponsored by EPRI and NREL with support from ASU. A dozen presentations and discussions introduced how the interplay of various technologies impact the value of PV, identified technical challenges and gaps impeding implementation, and discussed future R&D needs and opportunities.

  3. Heritage plaza parking lots improvement project- Solar PV installation

    Energy Technology Data Exchange (ETDEWEB)

    Hooks, Todd [Agua Caliente Indian Reservation, Palm Springs, CA (United States)

    2017-03-31

    The Agua Caliente Band of Cahuilla Indians (ACBCI or the “Tribe”) installed a 79.95 kW solar photovoltaic (PV) system to offset the energy usage costs of the Tribal Education and Family Services offices located at the Tribe's Heritage Plaza office building, 90I Tahquitz Way, Palm Springs, CA, 92262 (the "Project"). The installation of the Solar PV system was part of the larger Heritage Plaza Parking Lot Improvements Project and mounted on the two southern carport shade structures. The solar PV system will offset 99% of the approximately 115,000 kWh in electricity delivered annually by Southern California Edison (SCE) to the Tribal Education and Family Services offices at Heritage Plaza, reducing their annual energy costs from approximately $22,000 annually to approximately $200. The total cost of the proposed solar PV system is $240,000.

  4. PV GRID Advisory Paper. Consultation version: key recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Bianca; Concas, Giorgia; Cossent, Rafael; Franz, Oliver; Frias, Pablo; Hermes, Roland; Lama, Riccardo; Loew, Holger; Mateo, Carlos; Rekinger, Manoel; Sonvilla, Paolo Michele; Vandenbergh, Michel

    2014-01-15

    PV GRID is a transnational collaborative effort under the umbrella of the Intelligent Energy Europe programme. The main project goal is to enhance photovoltaic (PV) hosting capacity in distribution grids while overcoming regulatory and normative barriers hampering the application of available technical solutions. The European PV GRID advisory paper aims at providing an overview of the issues and barriers that need to be addressed in order to enhance the distribution grid hosting capacity for PV and other distributed generation (DG).To this purpose, barriers are classified as either cross-cutting challenges or specific barriers, depending on whether they have an overarching, system-wide character or rather focus on one single issue such as curtailment, self-consumption or storage. Finally, a set of preliminary recommendations on how to overcome these issues is presented, allowing for the implementation of the identified technical solutions.

  5. Robustness analysis of the efficiency in PV inverters

    DEFF Research Database (Denmark)

    Pigazo, Alberto; Liserre, Marco; Blaabjerg, Frede;

    2013-01-01

    During last years an increasing attention has been paid to the efficiency of grid-connected PV inverters. They are manufactured from a number of discrete components and by using a certain topology and control strategy. Hence, the performance of a certain PV inverter not only depends on the selected...... topology and control strategy but also on the characteristics of the employed components. The aim of this paper is evaluate the effect of physical variations associated to the main components on the overall efficiency of PV inverters. It is concluded that a statistical evaluation of the power converter...... provides a better understanding of the PV inverter performance and, in this sense, the definition of the European Efficiency must be reviewed in order to show the quality of the manufactured product....

  6. New test and characterization methods for PV modules and cells

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.; Sommeling, P. [ECN Solar Energy, Petten (Netherlands); Scholten, H. [Solland, Heerlen (Netherlands); Muller, J. [Moser-Baer, Eindhoven (Netherlands); Grossiord, N. [Holst Centre, Eindhoven (Netherlands); Smits, C.; Blanco Mantecon, M. [Holland Innovative, Eindhoven (Netherlands); Verheijen, M.; Van Berkum, J. [Philips Innovation Services, Eindhoven (Netherlands)

    2012-08-15

    The results of the project geZONd (shared facility for solar module analysis and reliability testing) are described. The project was set up by Philips, ECN, Holst, Solland, OM and T and Holland Innovative. The partners have shared most of their testing and analysis equipment for PV modules and cells, and together developed new or improved methods (including the necessary application know-how). This enables faster and more efficient innovation projects for each partner, and via commercial exploitation for other interested parties. The project has concentrated on five failure modes: corrosion, delamination, moisture ingress, UV irradiation, and mechanical bending. Test samples represented all main PV technologies: wafer based PV and rigid and flexible thin-film PV. Breakthroughs are in very early detection of corrosion, in quantitative characterization of adhesion, in-situ detection of humidity and oxygen inside modules, and ultra-fast screening of materials on UV stability.

  7. The Ramakrishna Mission economic PV development initiative

    Energy Technology Data Exchange (ETDEWEB)

    Stone, J.L.; Ullal, H.S. [National Renewable Energy Lab., Golden, CO (United States); Sherring, C. [Sherring Energy Associates, Princeton, NJ (United States)

    1998-09-01

    India is the world`s second most populous country, quickly approaching one billion persons. Although it has a well-developed electricity grid, many of the people have little or no access to electricity and all of the benefits associated with it. There are areas that are isolated from the grid and will not be connected for many years, if ever. One such area is the Sundarbans located in the delta region of the two great rivers, the Ganges and Brahmaputra, partially in India and partially in Bangladesh. It is estimated that 1.5 million people live in this area, crisscrossed by many islands and rivers, who have only marginal supplies of electricity generated primarily from diesel generators and batteries. Working with the regional non-governmental organization (NGO), the Ramakrishna Mission, and the West Bengal Renewable Energy Development Agency, the governments of India and the US initiated a rural electrification initiative to demonstrate the economic and technical feasibility of photovoltaics to provide limited supplies of electricity for such applications as solar home lighting systems (SHS), water pumping, vaccine refrigeration, communications, and economic development activities. This paper details initial results from approximately 30 kilowatts of PV systems installed in the area, including socio-economic impacts and technical performance.

  8. Promotional drivers for grid-connected PV

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Polo, A.; Hass, R.; Suna, D.

    2009-03-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at promotional measures for grid-connected photovoltaic systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the core objective of this study which was to analyse the success of various governmental regulatory programs and governmental and non-governmental marketing programs for grid-connected PV systems. To meet this objective, a review of the most important past and current programs around the world was conducted. The theoretical bases of supply and demand are explained and the types of existing strategies are documented in a second Section. In Chapter 3, various programs around the world are described. Chapter 4 focuses on defining success criteria which will be used for the analysis of the programs. Finally, the major conclusions drawn complete this analysis.

  9. Evaluation of PV Module Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, John; Silverman, Timothy; Miller, David C.; McNutt, Peter; Kempe, Michael; Deceglie, Michael

    2015-06-14

    This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.

  10. Performance and Degradation Analysis of Operating PV Systems

    Science.gov (United States)

    Da Silva Freire, Felipe

    The environmental concerns together with the decrease in technology cost lead the solar market to growth rapidly along the last decade. The photovoltaic (PV) systems are one of the solar energy alternatives and the silicon solar cells are currently the most widespread technology. Photovoltaic (PV) modules are considered the most reliable component of a photovoltaic system. The reliability and lifetime depends on the modules energy conversion performance and degradation modes. The analysis of monitoring data give insights about the PV system performance along its service time. The comparison between this data and mathematical models configure a way to predict the futures and new PV installations performance. The goal of this study is to understand the PV systems performance and degradation along its lifetime. A mathematical model was employed to predict the power output of a real, relatively new operating PV system with respect to environmental parameters temperature, irradiance and cloud coverage. The model used is based on one diode ideality factor and takes into account the parasitic series resistance. The results have been compared with the actual PV output data collected for the year 2014 and show good correlation. As the model predicts the system power output assuming the system in new conditions, the deviation in performance of the real data in comparison to the modeling results need to be further investigated for systems in service for longer time. For this propose, the study presents a condensed review of various causes of degradation in silicon PV modules and techniques to observe and investigate these degradation mechanisms. Major effects on output performance exhibit increase in observed ideality factor n2 and recombination current J02 primarily caused by decrease in minority carrier lifetime, shunts and increase in series resistance. The study further, investigates the governing degradation modes on a ten years old PV crystalline silicon module

  11. PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill

    2015-09-14

    A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

  12. Parallel experimental study of a novel super-thin thermal absorber based photovoltaic/thermal (PV/T system against conventional photovoltaic (PV system

    Directory of Open Access Journals (Sweden)

    Peng Xu

    2015-11-01

    Full Text Available Photovoltaic (PV semiconductor degrades in performance due to temperature rise. A super thin-conductive thermal absorber is therefore developed to regulate the PV working temperature by retrofitting the existing PV panel into the photovoltaic/thermal (PV/T panel. This article presented the parallel comparative investigation of the two different systems through both laboratory and field experiments. The laboratory evaluation consisted of one PV panel and one PV/T panel respectively while the overall field system involved 15 stand-alone PV panels and 15 retrofitted PV/T panels. The laboratory testing results demonstrated the PV/T panel could achieve the electrical efficiency of about 16.8% (relatively 5% improvement comparing with the stand-alone PV panel, and yield an extra amount of heat with thermal efficiency of nearly 65%. The field testing results indicated that the hybrid PV/T panel could enhance the electrical return of PV panels by nearly 3.5%, and increase the overall energy output by nearly 324.3%. Further opportunities and challenges were then discussed from aspects of different PV/T stakeholders to accelerate the development. It is expected that such technology could become a significant solution to yield more electricity, offset heating load freely and reduce carbon footprint in contemporary energy environment.

  13. Microgrid-Ready Solar PV; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-07-01

    Designing new solar projects to be 'microgrid-ready' enables the U.S. DoD, other federal agencies, and the private sector to plan future microgrid initiatives to utilize solar PV as a generating resource. This fact sheet provides background information with suggested language for several up-front considerations that can be added to a solar project procurement or request for proposal (RFP) that will help ensure that PV systems are built for future microgrid connection.

  14. Sensitivity to copper in Xanthomonas campestris pv. viticola

    OpenAIRE

    2009-01-01

    ABSTRACT Bacterial canker, caused by Xanthomonas campestris pv. viticola, affects grapevines in the irrigated areas of the São Francisco river valley, in the states of Pernambuco and Bahia. Several practices for disease management have been adopted including copper sprays.This is the only available chemical control method and most frequently used in the areas affected by the disease. The objective of this work was to determine the sensitivity to copper of strains of X. campestris pv. vi...

  15. Towards a PV-θ view of the general circulation

    Science.gov (United States)

    Hoskins, Brian J.

    1991-09-01

    In recent years, there has been a resurgence of interest in using isentropic coordinates and Rossby-Ertel potential vorticity (PV) for diagnosing the behaviour of middle latitude synoptic systems. Such a PV-θ analysis may also prove important in providing insight into the global circulation of the atmosphere. Apart from the isentropic diagnostic of D. Johnson and collaborators, some quasi-geostrophic studies and recent studies of stratospheric behaviour, there has been little work in this area and our present understanding is very limited. The object of the present paper is to stimulate such studies by presenting some initial results from continuing research. A three-fold division of the atmosphere is discussed. The "Overworld" is the region encompassed by isentropic surfaces that are everywhere above the tropopause. In the "Middleworld", the region with isentropes crossing the tropopause but not striking the Earth's surface, the isentropic zonal and time mean of PV exhibits interesting regions of enhanced and diminished gradients. The isentropic transient eddy advection of PV exhibits a dipolar distribution about the tropopause, suggestive of PV mixing. The marked PV signature of the Asian summer monsoon on one particular Middleworld isentrope is shown and the mean isentropic advection of PV shows interesting features. For the "Underworld", in which isentropic surfaces intercept the surface of the Earth, a PV-θ analysis yields a novel constraint linking low-level drag and diabatic heating. This constraint links "westerlies" and "cooling", and "easterlies" and "heating" in some average sense. The result is discussed in terms of the Southern Hemisphere strong surface westerlies and the circulation associated with the Asian summer and winter monsoons.

  16. Antagonism of Bacillus spp. against Xanthomonas campestris pv. campestris

    OpenAIRE

    Leila Monteiro; Rosa de Lima Ramos Mariano; Ana Maria Souto-Maior

    2005-01-01

    The antagonism of eight Bacillus isolates was investigated against nine strains of Xanthomonas campestris pv. campestris (causal agent of crucifers black rot) to assess the role of lipopeptides in this process. Antimicrobial and hemolytic (surfactant) activity tests were performed in vitro using agar diffusion methods. Antibiosis and hemolysis were positive for four Bacillus isolates against all X. campestris pv. campestris strains. The correlation observed between antimicrobial and hemolytic...

  17. Design optimization of transformerless grid-connected PV inverters including reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost Of the Ele......This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost...... to the non-optimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE....

  18. Control Strategies for the DAB Based PV Interface System

    Science.gov (United States)

    El-Helw, Hadi M.; Al-Hasheem, Mohamed; Marei, Mostafa I.

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system. PMID:27560138

  19. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  20. Review of PV Inverter Technology Cost and Performance Projections

    Energy Technology Data Exchange (ETDEWEB)

    Navigant Consulting Inc.

    2006-01-01

    The National Renewable Energy Laboratory (NREL) has a major responsibility in the implementation of the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program. Sandia National Laboratories (SNL) has a major role in supporting inverter development, characterization, standards, certifications, and verifications. The Solar Energy Technologies Program recently published a Multiyear Technical Plan, which establishes a goal of reducing the Levelized Energy Cost (LEC) for photovoltaic (PV) systems to $0.06/kWh by 2020. The Multiyear Technical Plan estimates that, in order to meet the PV system goal, PV inverter prices will need to decline to $0.25-0.30 Wp by 2020. DOE determined the need to conduct a rigorous review of the PV Program's technical and economic targets, including the target set for PV inverters. NREL requested that Navigant Consulting Inc.(NCI) conduct a review of historical and projected cost and performance improvements for PV inverters, including identification of critical barriers identified and the approaches government might use to address them.

  1. Battery Energy Storage System for PV Output Power Leveling

    Directory of Open Access Journals (Sweden)

    Rajkiran Singh

    2014-01-01

    Full Text Available Fluctuating photovoltaic (PV output power reduces the reliability in power system when there is a massive penetration of PV generators. Energy storage systems that are connected to the PV generators using bidirectional isolated dc-dc converter can be utilized for compensating the fluctuating PV power. This paper presents a grid connected energy storage system based on a 2 kW full-bridge bidirectional isolated dc-dc converter and a PWM converter for PV output power leveling. This paper proposes two controllers: a current controller using the d-q synchronous reference and a phase-shift controller. The main function of the current controller is to regulate the voltage at the high-side dc, so that the voltage ratio of the high-voltage side (HVS with low-voltage side (LVS is equal to the transformer turns ratio. The phase-shift controller is employed to manage the charging and discharging modes of the battery based on PV output power and battery voltage. With the proposed system, unity power factor and efficient active power injection are achieved. The feasibility of the proposed control system is investigated using PSCAD simulation.

  2. Residential Solar PV Systems in the Carolinas: Opportunities and Outcomes.

    Science.gov (United States)

    Alqahtani, Bandar Jubran; Holt, Kyra Moore; Patiño-Echeverri, Dalia; Pratson, Lincoln

    2016-02-16

    This paper presents a first-order analysis of the feasibility and technical, environmental, and economic effects of large levels of solar photovoltaic (PV) penetration within the services areas of the Duke Energy Carolinas (DEC) and Duke Energy Progress (DEP). A PV production model based on household density and a gridded hourly global horizontal irradiance data set simulates hourly PV power output from roof-top installations, while a unit commitment and real-time economic dispatch (UC-ED) model simulates hourly system operations. We find that the large generating capacity of base-load nuclear power plants (NPPs) without ramping capability in the region limits PV integration levels to 5.3% (6510 MW) of 2015 generation. Enabling ramping capability for NPPs would raise the limit of PV penetration to near 9% of electricity generated. If the planned retirement of coal-fired power plants together with new installations and upgrades of natural gas and nuclear plants materialize in 2025, and if NPPs operate flexibly, then the share of coal-fired electricity will be reduced from 37% to 22%. A 9% penetration of electricity from PV would further reduce the share of coal-fired electricity by 4-6% resulting in a system-wide CO2 emissions rate of 0.33 to 0.40 tons/MWh and associated abatement costs of 225-415 (2015$ per ton).

  3. Control Strategies for the DAB Based PV Interface System.

    Science.gov (United States)

    El-Helw, Hadi M; Al-Hasheem, Mohamed; Marei, Mostafa I

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system.

  4. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  5. Integrating High Penetrations of PV into Southern California

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, B.; Mather, B.; Hasper-Tuttle, J.; Neal, R.; Katiraei, F.; Yazdani, A.; Aguero, J. R.; Hoff, T. E.; Norris, B. L.; Parkins, A.; Seguin, R.; Schauder, C.

    2011-01-01

    California regulators recently approved a plan proposed by Southern California Edison (SCE) to install 500 MW of distributed photovoltaic (PV) energy in its utility service territory over the next 5 years. The installations will include 250 MW of utility-owned solar and 250 MW of independently owned solar. SCE expects that the majority of these systems will be commercial-scale rooftop PV systems connected at various points in the distribution system. Each of the SCE rooftop PV systems will typically have a rating of 1-3 MW. To understand the impact of high-penetration PV on the distribution grid, the National Renewable Energy Laboratory (NREL) and SCE brought together a team of experts in resource assessment, distribution modeling, and planning to help analyze the impacts of adding high penetration of PV into the distribution system. Through modeling and simulation, laboratory testing, and field demonstrations, the team will address the issues identified in the analysis by fully examining the challenges, developing solutions, and transitioning those solutions to the field for large-scale deployment. This paper gives an update on the project and discusses technical results of integrating a large number of distributed PV systems into the grid.

  6. Continuing Developments in PV Risk Management: Strategies, Solutions, and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Lowder, T.; Mendelsohn, M.; Speer, B.; Hill, R.

    2013-02-01

    As the PV industry matures, successful risk management practices will become more imperative to ensure investor confidence, control costs, and facilitate further growth. This report discusses several key aspects of risk management during the commercial- and utility-scale project life cycle, from identification of risks, to the process of mitigating and allocating those risks among project parties, to transferring those risks through insurance. The report also explores novel techniques in PV risk management, options to offload risks onto the capital markets, and innovative insurance policies (namely warranty policies) that address risks unique to the PV sector. One of the major justifications for robust risk management in the PV industry is the cost-reduction opportunities it affords. If the PV industry can demonstrate the capability to successfully manage its risks, thereby inspiring confidence in financiers, it may be able to obtain a lower cost of capital in future transactions. A lower cost of capital translates to a lower cost of energy, which will in turn enhance PV?s competitiveness at a time when it will have to rely less on subsidies to support its market penetration.

  7. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  8. Investigation of the Effect Temperature on Photovoltaic (PV) Panel Output Performance

    OpenAIRE

    Amelia Razak; Y.M. Irwan; W.Z. Leow; M Irwanto; I. Safwati; M. Zhafarina

    2016-01-01

    The main limit of PV systems is the low conversion efficiency of PV panels, which is strongly influenced by their operating temperature. Lack of accuracy in consideration through PV panel temperature increases the financial risk of system installation. This present study investigates the effects of operating temperature on monocrystalline PV panel at Perlis, Malaysia. A selected model of PV panel firstly was simulated using PVSYST software in order to evaluate its output performance. Meanwhil...

  9. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    OpenAIRE

    Tamer Khatib; Azah Mohamed; K. Sopian

    2012-01-01

    This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV) systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN), optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based mo...

  10. Proposal of Xanthomonas translucens pv. pistaciae pv. nov., pathogenic to pistachio (Pistacia vera).

    Science.gov (United States)

    Giblot-Ducray, Danièle; Marefat, Alireza; Gillings, Michael R; Parkinson, Neil M; Bowman, John P; Ophel-Keller, Kathy; Taylor, Cathy; Facelli, Evelina; Scott, Eileen S

    2009-12-01

    Strains of Xanthomonas translucens have caused dieback in the Australian pistachio industry for the last 15 years. Such pathogenicity to a dicotyledonous woody host contrasts with that of other pathovars of X. translucens, which are characterized by their pathogenicity to monocotyledonous plant families. Further investigations, using DNA-DNA hybridization, gyrB gene sequencing and integron screening, were conducted to confirm the taxonomic status of the X. translucens pathogenic to pistachio. DNA-DNA hybridization provided a clear classification, at the species level, of the pistachio pathogen as a X. translucens. In the gyrB-based phylogeny, strains of the pistachio pathogen clustered among the X. translucens pathovars as two distinct lineages. Integron screening revealed that the cassette arrays of strains of the pistachio pathogen were different from those of other Xanthomonas species, and again distinguished two groups. Together with previously reported pathogenicity data, these results confirm that the pistachio pathogen is a new pathovar of X. translucens and allow hypotheses about its origin. The proposed name is Xanthomonas translucens pv. pistaciae pv. nov.

  11. Large scale PV plants - also in Denmark. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Ahm, P. (PA Energy, Malling (Denmark)); Vedde, J. (SiCon. Silicon and PV consulting, Birkeroed (Denmark))

    2011-04-15

    Large scale PV (LPV) plants, plants with a capacity of more than 200 kW, has since 2007 constituted an increasing share of the global PV installations. In 2009 large scale PV plants with cumulative power more that 1,3 GWp were connected to the grid. The necessary design data for LPV plants in Denmark are available or can be found, although irradiance data could be improved. There seems to be very few institutional barriers for LPV projects, but as so far no real LPV projects have been processed, these findings have to be regarded as preliminary. The fast growing number of very large scale solar thermal plants for district heating applications supports these findings. It has further been investigated, how to optimize the lay-out of LPV plants. Under the Danish irradiance conditions with several winter months with very low solar height PV installations on flat surfaces will have to balance the requirements of physical space - and cost, and the loss of electricity production due to shadowing effects. The potential for LPV plants in Denmark are found in three main categories: PV installations on flat roof of large commercial buildings, PV installations on other large scale infrastructure such as noise barriers and ground mounted PV installations. The technical potential for all three categories is found to be significant and in the range of 50 - 250 km2. In terms of energy harvest PV plants will under Danish conditions exhibit an overall efficiency of about 10 % in conversion of the energy content of the light compared to about 0,3 % for biomass. The theoretical ground area needed to produce the present annual electricity consumption of Denmark at 33-35 TWh is about 300 km2 The Danish grid codes and the electricity safety regulations mention very little about PV and nothing about LPV plants. It is expected that LPV plants will be treated similarly to big wind turbines. A number of LPV plant scenarios have been investigated in detail based on real commercial offers and

  12. PV-HYBRID and MINI-GRID. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Within the 3rd European Conference at the Centre de Congres in Aix en Provence (France) between 11th and 12th May, 2006, the following lessons were held: (1) Small electric networks: European drivers and projects for the integration of RES and DG into the electricity grids of the future (Manuel Sanchez-Jimenez); (2) PV hybrid system within mini grids - IEA PVPS programme (Meuch Konraf); (3) Renewables for the developing world (Alvaro Ponce Plaza); (4) Rural electicity supply using photovoltaic / - Diesel hybrid systems: Attractive for investors in the renewable energy sector? (Andreas Hahn); (5) Economic analysis of stand-alone and grid-connected photovoltaic systems under current tariff structure of Taiwan (Yaw-Juen Wang); (6) Using wind-PV-diesel hybrid system for electrification of remote village in Western Libya (N.M. Kreama); (7) Venezuela's renewable energy program for small towns and rural areas ''Sembrando Luz'' (Jorge Torres); (8) AeroSmart5, the professional, sysem-compatible small-scale wind energy converter will be tested in field tests (Fabian Jochem); (9) Lifetime, test procedures and recommendations for optimal operating strategies for lead-acid-batteries in renewable energy systems - A survey on results from European projects from the 5th framework programme (Rudi Kaiser); (10) Prototype of a reversible fuel cell system for autonomous power supplies (Tom Smolinska); (11) Interconnection management in microgrids (Michel Vandenbergh); (12) Control strategy for a small-scale stand-alone power system based on renewable energy and hydrogen (Harald Miland); (13) Standard renewable electricity supply for people in rural areas - mini-grids in western provinces of China (Michael Wollny); (14) The Brava island a ''100% renewable energy'' project (Jean-Christian Marcel); (15) Breakthrough to a new era of PV-hybrid systems with the help of standardised components communication? (Michael Mueller); (16) Standardized

  13. Performance of a 34 kWp grid-connected PV system in Indonesia - A comparison of tropical and European PV systems

    NARCIS (Netherlands)

    Veldhuis, A.J.; Reinders, A.H.M.E.

    2014-01-01

    We analysed a monitored grid-connected PV system of 34 kWp in Indonesia to investigate the performance of PV systems in tropical climates. The PV system has been installed in Jayapura, the capital of the Province of Papua, Indonesia, by the beginning of 2012. Due to the aged gensets and frequent lac

  14. Plug and Play PV Systems for American Homes

    Energy Technology Data Exchange (ETDEWEB)

    Hoepfner, Christian [Fraunhofer USA, Inc., Boston, MA (United States)

    2016-12-22

    The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work during this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.

  15. PV-BUK: Operating and maintenance costs of photovoltaic installations; PV-BUK - Betriebs- und Unterhaltskosten von PV-Anlagen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Stettler, S.; Toggweiler, P. [Enecolo AG, Moenchaltorf (Switzerland); Ruoss, D.; Schudel, P. [Envision, Lucerne (Switzerland); Kottmann, A.; Steinle, F. [BE Netz AG, Lucerne (Switzerland)

    2008-03-15

    This final report elaborated for the Swiss Federal Office of Energy (SFOE) takes a look at the results of a project carried out to determine the costs for facility management, to estimate future cost development and to propose activities for the further reduction of the operation and maintenance costs of photovoltaic systems. Information on the cost situation was collected by literature study, as well as in interviews and surveys with photovoltaic (PV) experts and the owners of PV installations. The discussion of the results at a workshop with about 20 Swiss PV experts is noted. The results are presented and discussed. These show that operating costs per kWh decrease with the size of the PV system. Figures are quoted. The major part of the costs are quoted as being those for spare parts, especially for the inverter. The authors are of the opinion that, in future, costs for facility management will further decrease, as they are partly linked to capital and insurance costs. Potential for optimisation is said to exist in several areas of facility management such as, for example, in system monitoring and fast reaction in the case of malfunctions.

  16. Policies and opportunities for grid parity of PV in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Lako, P.; Beurskens, L.W.M. [ECN Policy Studies, Petten (Netherlands)

    2012-01-15

    In 2010, ECN Policy Studies has provided information on the development of solar PV in the Netherlands to GlobalData, India. Based on this information request, the present note on policies and opportunities for grid parity of PV has been drafted. Recently, subsidies for solar PV in the Netherlands have shown a pattern of a roller-coaster that is typical for PV financing in a number of EU countries. Stop-and-go policies for solar PV may have multiple causes. It may be difficult to determine the right feed-in tariffs for PV; or governments may be reluctant to provide sufficient funding for a relatively expensive renewable electricity source like PV. This note sheds light on the current state of affairs and policies for PV in the Netherlands, and on several private initiatives aimed at reaching grid parity for PV which is installed by households.

  17. Performance of a PV module augmented by a plane reflector

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, G. E; Hussein, H. M. S; Mohamad, M. A [Dokki, Giza (Egypt)

    2000-07-01

    This paper presents a comparative experimental study on the performance of a PV module augmented by a south facing titled plane reflector and another identical one without reflector. The tilt angles of the two PV modules and reflector overhang are selected to be according to a previous theoretical study by the authors. The reflector tilt angle has been changed once a month so that the reflected beams from the plane reflector cover the total surface area of the PV module all days of every month during the high solar radiation period (i.e. three hours before and after solar noon). The study has been carried out on the two PV modules for a complete year under the actual atmospheric conditions of Cairo, Egypt. The measuring system used in the study comprises a data acquisition system, a computer, an electronic load and weather station. The experimental results indicate that the plane reflector enhances the yearly output energy of the PV module y about 22%. [Spanish] Este articulo presenta un estudio comparativo experimental sobre el rendimiento de un modulo de PV aumentado por un reflector plano inclinado mirando hacia el sur y otro identico sin reflector. Los angulos de inclinacion de los dos modulos y el reflector sobresaliente se seleccionan para que esten de acuerdo con un estudio teorico previo hecho por los autores. El angulo de inclinacion del reflector se cambio una vez al mes de manera que los rayos reflejados por el reflector plano cubrieran el area total de la superficie del modulo de PV todos los dias de cada mes durante el periodo de radiacion alto (o sea tres horas antes y despues del medio dia solar). El estudio ha sido llevado a cabo en dos modulos de PV durante un ano completo bajo condiciones atmosfericas reales de El Cairo, Egipto. El sistema de medicion usado en el estudio comprende un sistema de adquisicion de datos, una computadora, una memoria electronica y una estacion climatologica. Los resultados experimentales indican que el reflector plano

  18. Thermal performances of vertical hybrid PV/T air collector

    Science.gov (United States)

    Tabet, I.; Touafek, K.; Bellel, N.; Khelifa, A.

    2016-11-01

    In this work, numerical analyses and the experimental validation of the thermal behavior of a vertical photovoltaic thermal air collector are investigated. The thermal model is developed using the energy balance equations of the PV/T air collector. Experimental tests are conducted to validate our mathematical model. The tests are performed in the southern Algerian region (Ghardaïa) under clear sky conditions. The prototype of the PV/T air collector is vertically erected and south oriented. The absorber upper plate temperature, glass cover temperature, air temperature in the inlet and outlet of the collector, ambient temperature, wind speed, and solar radiation are measured. The efficiency of the collector increases with increase in mass flow of air, but the increase in mass flow of air reduces the temperature of the system. The increase in efficiency of the PV/T air collector is due to the increase in the number of fins added. In the experiments, the air temperature difference between the inlet and the outlet of the PV/T air collector reaches 10 ° C on November 21, 2014, the interval time is between 10:00 and 14:00, and the temperature of the upper plate reaches 45 ° C at noon. The mathematical model describing the dynamic behavior of the typical PV/T air collector is evaluated by calculating the root mean square error and mean absolute percentage error. A good agreement between the experiment and the simulation results is obtained.

  19. Design of direct solar PV driven air conditioner

    KAUST Repository

    Huang, Bin-Juine

    2015-12-05

    © 2015 Elsevier Ltd. Solar air conditioning system directly driven by stand-alone solar PV is studied. The air conditioning system will suffer from loss of power if the solar PV power generation is not high enough. It requires a proper system design to match the power consumption of air conditioning system with a proper PV size. Six solar air conditioners with different sizes of PV panel and air conditioners were built and tested outdoors to experimentally investigate the running probabilities of air conditioning at various solar irradiations. It is shown that the instantaneous operation probability (OPB) and the runtime fraction (RF) of the air conditioner are mainly affected by the design parameter rpL (ratio of maximum PV power to load power). The measured OPB is found to be greater than 0.98 at instantaneous solar irradiation IT > 600 W m-2 if rpL > 1.71 RF approaches 1.0 (the air conditioner is run in 100% with solar power) at daily-total solar radiation higher than 13 MJ m-2 day-1, if rpL > 3.

  20. Planar holographic spectrum-splitting PV module design

    Science.gov (United States)

    Gordon, Michael; Zhang, Deming; Vorndran, Shelby; Russo, Juan M.; Luscombe, Christine K.; Shaheen, Sean E.; Kostuk, Raymond K.

    2012-10-01

    A design is presented for a planar spectrum-splitting photovoltaic (PV) module using Holographic Optical Elements (HOEs). A repeating array of HOEs diffracts portions of the solar spectrum onto different PV materials arranged in alternating strips. Several combinations of candidate PV materials are explored, and theoretical power conversion efficiency is quantified and compared for each case. The holograms are recorded in dichromated gelatin (DCG) film, an inexpensive material which is easily encapsulated directly into the panel. If desired, the holograms can focus the light to achieve concentration. The side-by-side split spectrum layout has advantages compared to a stacked tandem cell approach: since the cells are electrically isolated, current matching constraints are eliminated. Combinations of dissimilar types of cells are also possible: including crystalline, thin film, and organic PV cells. Configurations which yield significant efficiency gain using relatively inexpensive PV materials are of particular interest. A method used to optimize HOE design to work with a different candidate cells and different package aspect ratios is developed and presented. (Aspect ratio is width of the cell strips vs. the thickness of the panel) The relationship between aspect ratio and HOE performance properties is demonstrated. These properties include diffraction efficiency, spectral selectivity, tracking alignment sensitivity, and uniformity of cell illumination.

  1. Solar cell junction temperature measurement of PV module

    KAUST Repository

    Huang, B.J.

    2011-02-01

    The present study develops a simple non-destructive method to measure the solar cell junction temperature of PV module. The PV module was put in the environmental chamber with precise temperature control to keep the solar PV module as well as the cell junction in thermal equilibrium with the chamber. The open-circuit voltage of PV module Voc is then measured using a short pulse of solar irradiation provided by a solar simulator. Repeating the measurements at different environment temperature (40-80°C) and solar irradiation S (200-1000W/m2), the correlation between the open-circuit voltage Voc, the junction temperature Tj, and solar irradiation S is derived.The fundamental correlation of the PV module is utilized for on-site monitoring of solar cell junction temperature using the measured Voc and S at a short time instant with open circuit. The junction temperature Tj is then determined using the measured S and Voc through the fundamental correlation. The outdoor test results show that the junction temperature measured using the present method, Tjo, is more accurate. The maximum error using the average surface temperature Tave as the junction temperature is 4.8 °C underestimation; while the maximum error using the present method is 1.3 °C underestimation. © 2010 Elsevier Ltd.

  2. PV Reconfiguration Systems: a Technical and Economic Study

    Directory of Open Access Journals (Sweden)

    Caruso M.

    2017-03-01

    Full Text Available Dynamical electrical array reconfiguration strategies for grid-connected PV systems have been proposed as solution to improve energy production due to the mismatch effect of PV plants during partial shading conditions. Strategies are based on the use of dynamic connections between PV panels given by the employment of switches that allow for each panel the series, parallel or exclusion connections, physically changing the electrical connections between the related PV modules, consequentially modifying the layout of the plant. Usually the cost of the dynamic matrix is not taken into account. This novel work evaluates the economic advantages obtained by the use of reconfiguration strategies in PV systems, by taking into consideration the price of energy due to incentives in different European and non-European countries and correlates it with the employment of two types of reconfigurators, with different internal structures. For each of the incentives proposed by the different Countries, the main strength and weakness points of the possible investment are highlighted and critically analyzed. From this analysis, it can be stated that the adoption of reconfiguration systems, in certain cases, can be a very convenient solution.

  3. Durability Quality Research of Concrete Containing Solar PV Cells

    Directory of Open Access Journals (Sweden)

    Chao Sao-Jeng

    2015-01-01

    Full Text Available In this article we demonstrated the study results of durability quality of concrete containing waste solar PV cells. The study used alkali activator to improve the activity of alkali-activated materials in solar PV cells so as to replace Portland cement as binder in concrete. By using sodium hydroxide as an alkali-activator, a high-pH environment is generated to excite the binding characteristics of alkali-activated materials in solar PV cells, and thus develops better durability of the mixes. The conclusions were made on effect of this cement replacement. As a result, we identified the durability for those of 16 concrete specimens predefined and made to consider various possible control factors. The conclusions also depicted that all experiments but the drying shrinkage may be helpful with the suitable use of control factors as far as concerning the recycled solar PV cells for mixing in concrete. In other words, the durability quality of concrete may be partially unacceptable of containing solar PV cells.

  4. Photovoltaic Module Simulink Model for a Stand-alone PV System

    Science.gov (United States)

    Qi, Chen; Ming, Zhu

    Photovoltaic(PV) Module is indispensable of a stand-alone PV system. In this paper, a one-diode equivalent circuit-based versatile simulation model in the form of masked block PV module is proposed. By the model, it is allowed to estimate behavior of PV module with respect changes on irradiance intensity, ambient temperature and parameters of the PV module. In addition, the model is capable of function of Maximum Power Point Tracking (MPPT) which can be used in the dynamic simulation of stand-alone PV systems.

  5. Lifetime Evaluation of Grid-Connected PV Inverters Considering Panel Degradation Rates and Installation Sites

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    Lifetime of PV inverters is affected by the installation sites related to different solar irradiance and ambient temperature profiles (also referred to as mission profiles). In fact, the installation site also affects the degradation rate of the PV panels, and thus long-term energy production...... and reliability. Prior-art lifetime analysis in PV inverters has not yet investigated the impact of PV panel degradations. This paper thus evaluates the lifetime of PV inverters considering panel degradation rates and mission profiles. Evaluations have been carried out on PV systems installed in Denmark...

  6. Interline Photovoltaic (I-PV) power system - A novel concept of power flow control and management

    OpenAIRE

    2011-01-01

    This paper presents a new system configuration for a large-scale Photovoltaic (PV) power system with multi-line transmission/distribution networks. A PV power plant is reconfigured in a way that two adjacent power system networks/ feeders can be interconnected. The inverter modules in a PV power plant are configured such that the system is represented as a back to back inverter connected multi-line system, called as Interline-PV (I-PV) system. The proposed I-PV system then can be controlled a...

  7. Review of Solar PV Market Development in East Africa

    DEFF Research Database (Denmark)

    Hansen, Ulrich Elmer; Pedersen, Mathilde Brix; Nygaard, Ivan

    While the diffusion of solar home systems in Kenya has been market-based for some years, the diffusion of PV in most other Sub-Saharan African countries has been driven by government and donor-supported projects aimed at serving specific needs for electricity while at the same time creating...... to varying degrees by conducive enabling frameworks comprising innovative financing schemes, exemptions from VAT and import taxes, standardised power-purchasing agreements and feed-in tariffs. Few analyses have so far been conducted on the effects of such measures. This paper aims to contribute...... the development of PV markets not only in terms of installed capacity and market volume, but also with regard to local industry and PV business development. The paper concludes by drawing attention to particular factors that have been used in the literature to explain disparities in market...

  8. Z - Source Multi Level Inverter Based PV Generation System

    Directory of Open Access Journals (Sweden)

    T. Lakhmi kanth

    2014-09-01

    Full Text Available In this paper a novel technique of Z-Source multilevel Inverter based PV Generation system is implemented and simulated using MATLAB-Simulink simulation software. The Photovoltaic cells are healthier option for converting solar energy into electricity. Due to high capital cost and low efficiency PV cells have not yet been a fully smart choice for electricity users. To enhance the performance of the system, Z-Source multi level inverter can be used in place of conventional Voltage Source Inverter (VSI in Solar Power Generation System. The PV cell model is developed using circuit mathematical equations. The Z-Source multilevel inverter is modeled to realize boosted DC to AC conversion (inversion with low THD. Outcome shows that the energy conversion efficiency of ZSMLI is a lot improved as compared to conventional voltage Source Inverter (VSI. By doing FFT analysis we can know the total THD.

  9. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Weng, Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefit the industry at-large.

  10. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Weng, Dean [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefi t the industry at-large.

  11. Sizing aspects of a small scale grid connected PV system

    Energy Technology Data Exchange (ETDEWEB)

    Bartha, S.; Teodoreanu, D.I.; Teodoreanu, M.; Negreanu, C. [I.C.P.E.-New Energy Sources Laboratory (NESL), Bucharest (Romania); Farkas, I.; Seres, I. [Szent Istvan University, Goedoelloe (Hungary). Department of Physics and Process Control

    2008-07-01

    Photovoltaics can be used in grid connected mode in two ways: as array installed at the end use site, such as on rooftops, or as utility-scale generating stations. The present paper describes a small-scale grid connected Photovoltaic system. The paper starts with the structure and characterization of the system. The principal technical parameter data are also presented. The used monitoring parameters indicate the principal meteorological data, air temperature and solar radiation data for the location sited at Agigea, at the Black Sea and the produced energy by the PV modules. The present application is made by 1 subsystem with 1200 Wp power and with the panel inclination possibility, using different type of PV modules. The paper presents a simulation model for this system realized with commercial software packages and with a one self made Matlab model that evaluates the energy balance of the PV system. All the simulation and measurements data are presented. (orig.)

  12. PV Systems Installed in Marine Vessels: Technologies and Specifications

    Directory of Open Access Journals (Sweden)

    Ioannis Kobougias

    2013-01-01

    Full Text Available Considerations are held about the specificationin whichthe PV plants have to fulfill so that they can be installed on marine vessels. Initially, a brief description of the typical electrical grid of ships is presented, distinguishing the main parts, reporting the typical electrical magnitudes, and choosing the most preferable installation areas. The technical specifications,in whichthe PV plants have to be compatible with, are fully described. They are determined by the special marine environmental conditions, taking into consideration parameters like wind, humidity, shading, corrosion, and limited installation area. The work is carried out with the presentation of the most popular trends in the field of solar cell types and PV system technologies and their ability to keep up with the aforementioned specifications.

  13. DC-PLC Modem design for PV module monitoring

    Directory of Open Access Journals (Sweden)

    Seong-Duc Ma

    2016-01-01

    Full Text Available Nowadays, power line communication (PLC is a very efficient technique in cost aspect because it is communication system using power line without extra communication cables. In case of DC-PLC, it send a communication signal of the high frequency band to the monitoring system through the DC power line and is widely used for DC grid or the distributed generation system using DC source. Especially, the management system which evaluates the performance and efficiency of PV module by measuring PV power through monitoring system based on the DC-PLC has been increased. In this paper, apply the DC-PLC method for low cost PV module monitoring system and constitutes a measuring device and communication modem on a MCU. For the communication performance, we use the digital filter and apply the multi-carrier communication. The proposed DC-PLC Modem is verified through simulation and experiment.

  14. Chapter 10.3: Reliability and Durability of PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah

    2017-01-07

    Each year the world invests tens of billions of dollars or euros in PV systems with the expectation that these systems will last approximately 25 years. Although the disciplines of reliability, quality, and service life prediction have been well established for numerous products, a full understanding of these is currently challenging for PV modules because the desired service lifetimes are decades, preventing direct verification of lifetime predictions. A number of excellent reviews can be found in the literature summarizing the types of failures that are commonly observed for PV modules. This chapter discusses key failure/degradation mechanisms selected to highlight how the kinetics of failure rates can and cannot be confidently predicted. For EVA-encapsulated modules, corrosion is observed to follow delamination, which then allows water droplets to directly contact the metallization. Extended test protocols such as Qualification Plus were created to address the known problems while standards groups update standard tests through the consensus process.

  15. Lessons Learned from the Photovoltaic Manufacturing Technology/PV Manufacturing R&D and Thin Film PV Partnership Projects

    Energy Technology Data Exchange (ETDEWEB)

    Margolis, R.; Mitchell, R.; Zweibel, K.

    2006-09-01

    As the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program initiates new cost-shared solar energy R&D under the Solar America Initiative (SAI), it is useful to analyze the experience gained from cost-shared R&D projects that have been funded through the program to date. This report summarizes lessons learned from two DOE-sponsored photovoltaic (PV) projects: the Photovoltaic Manufacturing Technology/PV Manufacturing R&D (PVMaT/PVMR&D) project and the Thin-Film PV Partnership project. During the past 10-15 years, these two projects have invested roughly $330 million of government resources in cost-shared R&D and leveraged another $190 million in private-sector PV R&D investments. Following a description of key findings and brief descriptions of the PVMaT/PVMR&D and Thin-Film PV Partnership projects, this report presents lessons learned from the projects.

  16. Pseudomonas cannabina pv. cannabina pv. nov., and Pseudomonas cannabina pv. alisalensis (Cintas Koike and Bull, 2000) comb. nov., are members of the emended species Pseudomonas cannabina (ex Sutic & Dowson 1959) Gardan, Shafik, Belouin, Brosch, Grimont & Grimont 1999.

    Science.gov (United States)

    Bull, Carolee T; Manceau, Charles; Lydon, John; Kong, Hyesuk; Vinatzer, Boris A; Fischer-Le Saux, Marion

    2010-04-01

    Sequence similarity in the 16S rDNA gene confirmed that crucifer pathogen Pseudomonas syringae pv. alisalensis belongs to P. syringae sensu lato. In reciprocal DNA/DNA hybridization experiments, DNA relatedness was high (69-100%) between P. syringae pv. alisalensis strains and the type strain of P. cannabina (genomospecies 9). In contrast, DNA relatedness was low (below 48%) between P. syringae pv. alisalensis and reference strains from the remaining genomospecies of P. syringae including the type strain of P. syringae and reference strain of genomospecies 3 (P. syringae pv. tomato) although the well-known crucifer pathogen, P. syringae pv. maculicola, also belongs to genomospecies 3. Additional evidence that P. syringae pv. alisalensis belongs to P. cannabina was sequence similarity in five gene fragments used in multilocus sequence typing, as well as similar rep-PCR patterns when using the BOX-A1R primers. The description of P. cannabina has been emended to include P. syringae pv. alisalensis. Host range testing demonstrated that P. syringae pv. alisalensis strains, originally isolated from broccoli, broccoli raab or arugula, were not pathogenic on Cannabis sativa (family Cannabinaceae). Additionally, P. cannabina strains, originally isolated from the C. sativa were not pathogenic on broccoli raab or oat while P. syringae pv. alisalensis strains were pathogenic on these hosts. Distinct host ranges for these two groups indicate that P. cannabina emend. consists of at least two distinct pathovars, P. cannabina pv. cannabina pv. nov., and P. cannabina pv. alisalensis comb. nov. Pseudomonas syringae pv. maculicola strain CFBP 1637 is a member of P. cannabina.

  17. Time series power flow analysis for distribution connected PV generation.

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J.; Smith, Jeff; Dugan, Roger

    2013-01-01

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating

  18. Design, Fabrication and Certification of Advanced Modular PV Power Systems

    Science.gov (United States)

    Minyard, Glen E.; Lambarski, Timothy J.

    1997-02-01

    The Design, Fabrication and Certification of Advanced Modular PV Power Systems contract is a Photovoltaic Manufacturing Technology (PVMaT) cost-shared contract under Phase 4A1 for Product Driven Systems and Component Technologies. Phase 4A1 has the goals to improve the cost-effectiveness and manufacturing efficiency of PV end-products, optimize manufacturing and packaging methods, and generally improve balance-of-system performance, integration and manufacturing. This contract has the specific goal to reduce the installed PV system life cycle costs to the customer with the ultimate goal of increasing PV system marketability and customer acceptance. The specific objectives of the project are to develop certified, standardized, modular, pre-engineered products lines of our main stand-alone systems, the Modular Autonomous PV Power Supply (MAPPS) and PV-Generator Hybrid System (Photogenset). To date, we have designed a 200 W MAPPS and a 1 kW Photogenset and are in the process of having the MAPPS certified by Underwriters Laboratories (UL Listed) and approved for hazardous locations by Factory Mutual (FM). We have also developed a manufacturing plan for product line expansion for the MAPPS. The Photogenset will be fabricated in February 1997 and will also be UL Listed. Functionality testing will be performed at NREL and Sandia with the intentions of providing verification of performance and reliability and of developing test-based performance specifications. In addition to an expansion on the goals, objectives and status of the project, specific accomplishments and benefits are also presented in this paper.

  19. Design and Implementation of A PV Powered Tri-Cycle

    Directory of Open Access Journals (Sweden)

    Soumya Das

    2016-04-01

    Full Text Available Solar PV technology is one of the first among the various renewable energy technologies that have been adopted and accepted universally in order to meet the basic needs of generation of electricity. The objective of this paper is to propose a tri-cycle that utilises the application of stand-alone photovoltaic (PV system. A preliminary design and construction of a solar tri-cycle has been performed by evaluating and estimating the required panel size, battery capacity and motor power. Calculation in this paper exhibit that the solar power alone will be sufficient to operate a tri-cycle from one place to another.

  20. PV domestic field trial. Third annual technical report

    Energy Technology Data Exchange (ETDEWEB)

    Crick, F.; Davies, N.; Munzinger, M.; Pearsall, N.; Martin, C.

    2004-07-01

    This report summaries the results of a field trials investigating the design, construction and operation of photovoltaic (PV) systems installed during 2003 to provide information for utilities, building developers and those involved in PV installations and operations. Topics examined include the appearance of the systems, their architectural integration, the different fixing methods, the cost effectiveness of the systems, problems encountered, and monitoring activities. Key issues discussed include communication and co-ordination between interested bodies, siting and location, and good practice. Details are given of monitoring inspection visits, and performance analysis.

  1. Spatio-temporal analysis of regional PV generation

    DEFF Research Database (Denmark)

    Nuño Martinez, Edgar; Cutululis, Nicolaos Antonio

    2016-01-01

    Photovoltaic (PV) power is growing in importance worldwide and hence needs to be represented in operation and planning of power system. As opposed to traditional generation technologies, it is characterized by exhibiting both a high variability and a significant spatial dependence. This paper...... presents a fundamental analysis of regional solar generation time series, aiming to potentially facilitate large-scale solar integration. It will focus on characterizing the underlying dependence structure at the system level as well as describing both statistical and temporal properties of regional PV...

  2. Modular Power Converters for PV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need

  3. Task 9. PV deployment in developing countries. Institutional framework and financial instruments for PV deployment in developing countries

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-09-15

    This report for the International Energy Agency (IEA) made by Task 9 of the Photovoltaic Power Systems (PVPS) programme takes a look at the institutional framework and financial instruments necessary for PV deployment in developing countries. This guide describes the institutional and financial aspects that need to be addressed to ensure that a long term sustainable (and profitable) PV market is established in developing countries. The guide details main fundamental functions that need to be performed such as the agents needed to perform the functions and their differing roles within the framework, the relationships between these agents and the financial instruments available. It is stated that the majority of the aspects recommended in this guide can be adopted to two main PV deployment models: direct sales and rural electrification and development programmes. It is noted that both approaches will have to be tailored and adapted to local conditions.

  4. NCBI nr-aa BLAST: CBRC-XTRO-01-2352 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-2352 ref|NP_642468.1| YapH protein [Xanthomonas axonopodis pv. citri s...tr. 306] gb|AAM37004.1| YapH protein [Xanthomonas axonopodis pv. citri str. 306] NP_642468.1 0.30 32% ...

  5. NCBI nr-aa BLAST: CBRC-LAFR-01-1946 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-1946 ref|NP_641456.1| hypothetical protein XAC1119 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM35992.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641456.1 0.50 39% ...

  6. NCBI nr-aa BLAST: CBRC-XTRO-01-2343 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-2343 ref|NP_642141.1| filamentous haemagglutinin [Xanthomonas axonopod...is pv. citri str. 306] gb|AAM36677.1| filamentous haemagglutinin [Xanthomonas axonopodis pv. citri str. 306] NP_642141.1 6e-04 27% ...

  7. NCBI nr-aa BLAST: CBRC-LAFR-01-0106 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-0106 ref|NP_643310.1| MFS transporter [Xanthomonas axonopodis pv. citr...i str. 306] gb|AAM37846.1| MFS transporter [Xanthomonas axonopodis pv. citri str. 306] NP_643310.1 0.54 26% ...

  8. NCBI nr-aa BLAST: CBRC-PTRO-23-0017 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-PTRO-23-0017 ref|NP_642953.1| phage-related terminase [Xanthomonas axonopodis ...pv. citri str. 306] gb|AAM37489.1| phage-related terminase [Xanthomonas axonopodis pv. citri str. 306] NP_642953.1 5.6 33% ...

  9. NCBI nr-aa BLAST: CBRC-LAFR-01-1513 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-1513 ref|NP_643310.1| MFS transporter [Xanthomonas axonopodis pv. citr...i str. 306] gb|AAM37846.1| MFS transporter [Xanthomonas axonopodis pv. citri str. 306] NP_643310.1 1.1 24% ...

  10. NCBI nr-aa BLAST: CBRC-LAFR-01-1577 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-LAFR-01-1577 ref|NP_641723.1| hypothetical protein XAC1388 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36259.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641723.1 0.077 39% ...

  11. NCBI nr-aa BLAST: CBRC-DNOV-01-2969 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DNOV-01-2969 ref|NP_641277.1| hypothetical protein XAC0925 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM35813.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641277.1 3.0 27% ...

  12. NCBI nr-aa BLAST: CBRC-ACAR-01-0078 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ACAR-01-0078 ref|NP_644793.1| avirulence protein [Xanthomonas axonopodis pv. c...itri str. 306] gb|AAM39311.1| avirulence protein [Xanthomonas axonopodis pv. citri str. 306] NP_644793.1 2e-04 26% ...

  13. NCBI nr-aa BLAST: CBRC-XTRO-01-0707 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-0707 ref|NP_644475.1| acetate permease [Xanthomonas axonopodis pv. cit...ri str. 306] gb|AAM39011.1| solute:Na+ symporter [Xanthomonas axonopodis pv. citri str. 306] NP_644475.1 1e-136 79% ...

  14. NCBI nr-aa BLAST: CBRC-DRER-13-0011 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DRER-13-0011 ref|NP_642674.1| hypothetical protein XAC2357 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM37210.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_642674.1 5e-05 30% ...

  15. NCBI nr-aa BLAST: CBRC-XTRO-01-0645 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-XTRO-01-0645 ref|NP_642163.1| hypothetical protein XAC1837 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36699.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_642163.1 9e-42 40% ...

  16. NCBI nr-aa BLAST: CBRC-DYAK-01-0032 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DYAK-01-0032 ref|NP_640378.1| D-3-phosphoglycerate dehydrogenase [Xanthomonas ...axonopodis pv. citri str. 306] gb|AAM34914.1| D-3-phosphoglycerate dehydrogenase [Xanthomonas axonopodis pv. citri str. 306] NP_640378.1 1.1 32% ...

  17. NCBI nr-aa BLAST: CBRC-ACAR-01-0713 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ACAR-01-0713 ref|NP_641889.1| glucose-galactose transporter [Xanthomonas axono...podis pv. citri str. 306] gb|AAM36425.1| glucose-galactose transporter [Xanthomonas axonopodis pv. citri str. 306] NP_641889.1 4.7 35% ...

  18. NCBI nr-aa BLAST: CBRC-BTAU-01-1628 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-BTAU-01-1628 ref|NP_641751.1| phosphatidate cytidylyltransferase [Xanthomonas ...axonopodis pv. citri str. 306] gb|AAM36287.1| phosphatidate cytidylyltransferase [Xanthomonas axonopodis pv. citri str. 306] NP_641751.1 6.8 24% ...

  19. NCBI nr-aa BLAST: CBRC-DYAK-06-0020 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DYAK-06-0020 ref|NP_642141.1| filamentous haemagglutinin [Xanthomonas axonopod...is pv. citri str. 306] gb|AAM36677.1| filamentous haemagglutinin [Xanthomonas axonopodis pv. citri str. 306] NP_642141.1 0.001 26% ...

  20. NCBI nr-aa BLAST: CBRC-BTAU-01-2358 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-BTAU-01-2358 ref|NP_641879.1| hypothetical protein XAC1546 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36415.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641879.1 5.2 31% ...

  1. NCBI nr-aa BLAST: CBRC-ACAR-01-0078 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ACAR-01-0078 ref|NP_644725.1| avirulence protein [Xanthomonas axonopodis pv. c...itri str. 306] gb|AAM39243.1| avirulence protein [Xanthomonas axonopodis pv. citri str. 306] NP_644725.1 2e-04 26% ...

  2. NCBI nr-aa BLAST: CBRC-DRER-13-0009 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DRER-13-0009 ref|NP_642674.1| hypothetical protein XAC2357 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM37210.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_642674.1 5e-05 30% ...

  3. NCBI nr-aa BLAST: CBRC-DDIS-03-0106 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DDIS-03-0106 ref|NP_643514.1| hypothetical protein XAC3206 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM38050.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_643514.1 2e-31 30% ...

  4. NCBI nr-aa BLAST: CBRC-DNOV-01-3199 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DNOV-01-3199 ref|NP_641280.1| extracellular protease [Xanthomonas axonopodis p...v. citri str. 306] gb|AAM35816.1| extracellular protease [Xanthomonas axonopodis pv. citri str. 306] NP_641280.1 5.1 25% ...

  5. NCBI nr-aa BLAST: CBRC-GGAL-35-0330 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-GGAL-35-0330 ref|NP_641879.1| hypothetical protein XAC1546 [Xanthomonas axonop...odis pv. citri str. 306] gb|AAM36415.1| conserved hypothetical protein [Xanthomonas axonopodis pv. citri str. 306] NP_641879.1 0.034 26% ...

  6. NCBI nr-aa BLAST: CBRC-ETEL-01-0961 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-ETEL-01-0961 ref|NP_644405.1| dipeptidyl peptidase [Xanthomonas axonopodis pv.... citri str. 306] gb|AAM38941.1| dipeptidyl peptidase [Xanthomonas axonopodis pv. citri str. 306] NP_644405.1 0.67 54% ...

  7. NCBI nr-aa BLAST: CBRC-DNOV-01-1305 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DNOV-01-1305 ref|NP_640667.1| vanillate O-demethylase oxygenase subunit [Xanth...omonas axonopodis pv. citri str. 306] gb|AAM35203.1| vanillate O-demethylase oxygenase subunit [Xanthomonas axonopodis pv. citri str. 306] NP_640667.1 5.1 38% ...

  8. Draft genome sequences of five Pseudomonas syringae pv. actinidifoliorum strains isolated in France.

    Science.gov (United States)

    Cunty, Amandine; Cesbron, Sophie; Briand, Martial; Carrère, Sébastien; Poliakoff, Françoise; Jacques, Marie-Agnès; Manceau, Charles

    2016-01-01

    Pseudomonas syringae pv. actinidifoliorum causes necrotic spots on the leaves of Actinidia deliciosa and Actinidia chinensis. P. syringae pv. actinidifoliorum has been detected in New Zealand, Australia, France and Spain. Four lineages were previously identified within the P. syringae pv. actinidifoliorum species group. Here, we report the draft genome sequences of five strains of P. syringae pv. actinidifoliorum representative of lineages 1, 2 and 4, isolated in France. The whole genomes of strains isolated in New Zealand, representative of P. syringae pv. actinidifoliorum lineages 1 and 3, were previously sequenced. The availability of supplementary P. syringae pv. actinidifoliorum genome sequences will be useful for developing molecular tools for pathogen detection and for performing comparative genomic analyses to study the relationship between P. syringae pv. actinidifoliorum and other kiwifruit pathogens, such as P. syringae pv. actinidiae.

  9. Draft genome sequences of five Pseudomonas syringae pv. actinidifoliorum strains isolated in France

    Directory of Open Access Journals (Sweden)

    Amandine Cunty

    Full Text Available ABSTRACT Pseudomonas syringae pv. actinidifoliorum causes necrotic spots on the leaves of Actinidia deliciosa and Actinidia chinensis. P. syringae pv. actinidifoliorum has been detected in New Zealand, Australia, France and Spain. Four lineages were previously identified within the P. syringae pv. actinidifoliorum species group. Here, we report the draft genome sequences of five strains of P. syringae pv. actinidifoliorum representative of lineages 1, 2 and 4, isolated in France. The whole genomes of strains isolated in New Zealand, representative of P. syringae pv. actinidifoliorum lineages 1 and 3, were previously sequenced. The availability of supplementary P. syringae pv. actinidifoliorum genome sequences will be useful for developing molecular tools for pathogen detection and for performing comparative genomic analyses to study the relationship between P. syringae pv. actinidifoliorum and other kiwifruit pathogens, such as P. syringae pv. actinidiae.

  10. Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated such that......This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated...... that compared to the nonoptimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE....

  11. Methods for the Optimal Design of Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    characteristics on the design of grid-connected PV inverters have been considered. The proposed methods have been applied for the optimal design of PV inverters installed at various sites in Europe. The simulation results verify that the proposed optimization techniques enable the maximization of the PV energy......The DC/AC inverters are used in grid-connected PV energy production systems as the power processing interface between the PV energy source and the electric grid. The energy injected into the electric grid by the PV installation depends on the amount of power extracted from the PV power source...... injected into the electric grid, thus serving as a tool to gain more energy by the optimized PV installation....

  12. Ação de tinturas e óleos essenciais de plantas medicinais sobre o crestamento bacteriano comum do feijoeiro e na produção de proteínas de indução de resistência

    Directory of Open Access Journals (Sweden)

    Sandra Cristina Vigo

    2009-12-01

    Full Text Available A exploração da atividade biológica de compostos secundários presentes nas tinturas ou em óleos essenciais de plantas podem representar, ao lado da indução de resistência, mais uma forma potencial de controle de doenças em plantas cultivadas. O presente trabalho objetivou avaliar o potencial de tinturas de Lippia alba, Lippia sidoides, Mikania glomerata, Equisetum sp. e Hedera helix e óleos essenciais de Rosmarinus officinalis e Cinnamomum zeylanicum nas atividades in vitro, in vivo e na produção de proteínas na indução de resistência, em plantas de feijão vagem cultivar Bragança. Os resultados obtidos demonstraram que as tinturas de L. alba e L. sidoides e os óleos essenciais (R. officinalis e C. zeylanicum apresentaram atividade in vitro aos isolados de Xanthomonas axonopodis pv. phaseoli. Todas as tinturas ensaiadas apresentaram menores valores do progresso da doença (AACPD, em relação à testemunha, merecendo destaque a tintura de L. alba, que estavam correlacionadas com os maiores teores de polifenoloxidase, peroxidase e proteínas solúveis totais, evidenciando uma possível indução de resistência. Os óleos essenciais não apresentaram diferença na AACPD e nem na indução de proteínas.Additionally to resistance inducers, the exploitation of secondary compounds biological activity present in plants alcohol extracts or essential oils could potential way to control diseases in cultivated plants. This aimed to evaluate the potential of Lippia alba, Lippia sidoides, Mikania glomerata, Equisetum sp. and Hedera helix alcohol extracts and, Rosmarinus officinalis and Cinnamomum zeylanicum essential oils on in vitro and in vivo activity, and protein production on resistance induction in snap beans Bragança cultivar. Results showed in vitro activity against Xanthomonas axonopodis pv. phaseoli for L. alba and L. sidoides extracts, and essential oils. Although all alcohol extracts have showed the lowest area under the

  13. Método generalizado de análise de dialelos desbalanceados Generalized method for analysis of unbalanced diallels

    Directory of Open Access Journals (Sweden)

    SÍLVIA AGRIPINA GONÇALVES E SILVA

    2000-10-01

    Full Text Available Apresenta-se um procedimento generalizado de estimação das capacidades geral e específica de combinação em cruzamentos dialélicos, com número desigual de repetições para tratamentos (genitores e combinações híbridas F1, avaliados em um delineamento com restrições na casualização. Neste caso, as médias ajustadas estimadas são interdependentes e heterocedásticas, devendo-se, para estimar os parâmetros desejados, utilizar o modelo linear generalizado de GaussMarkov. O objetivo deste trabalho foi a dedução teórica do método e sua aplicação a um exemplo prático. Foram analisados os dados obtidos de um dialelo completo, sem os recíprocos, envolvendo cinco genitores: CB 511687-1, CB 733753, Diamante Negro, Rosinha G2 e Compuesto Chimaltenango 2. Os genitores CB 733753, CB 511687-1 e Diamante Negro contribuem geneticamente para a resistência, enquanto Rosinha G2 e Compuesto Chimaltenango 2 contribuem para a suscetibilidade do feijoeiro ao crestamento-bacteriano comum. Na maioria dos cruzamentos analisados constatou-se a dominância parcial da suscetibilidade do feijoeiro a Xanthomonas axonopodis pv. phaseoli.A general procedure for estimation of general and specific combining ability in diallelic crosses with unequal number of replications for treatments (parents and F1 hybrid combinations, evaluated in a design with restricted randomization, is presented. In this case, the estimates of adjusted means are interdependent and heterocedastic, demanding the use of the GaussMarcov generalized linear model. The objective of this study was the theoretical deduction of the model and its application to a practical example. A complete diallel crossing without reciprocals was performed, including five parents: CB 511687-1, CB 733753, Diamante Negro, Rosinha G-2 and Compuesto Chimaltenango 2. The parents CB 511687-1, CB 733753 and Diamante Negro contribute genetically for resistance while Rosinha G-2 and Compuesto Chimaltenango 2

  14. PV-θ view of the zonal mean state of the atmosphere

    Directory of Open Access Journals (Sweden)

    Aarnout J. Van Delden

    2012-08-01

    Full Text Available The relation between zonal mean potential vorticity (PV in potential temperature (θ coordinates and the zonal mean zonal wind in January and in July is studied. PV-anomalies are defined with respect to a reference state that is at rest with respect to the rotating earth. Two important PV-anomalies are identified. One PV-anomaly, the ‘Ex-UTLS PV-anomaly’, coincides approximately with the extratropical tropopause (310–360 K. It is a permanent feature of the zonal mean state. The other PV-anomaly is located higher in the stratosphere. It exhibits a strong seasonal cycle, i.e. in winter, it is strongly positive, while in summer, it is weakly negative. In the Northern Hemisphere winter, the Ex-UTLS PV-anomaly and the stratospheric PV-anomaly are separated by a ‘surf-zone’, which is characterised by a negative PV-anomaly pole-wards of a positive PV-anomaly. Piecewise PV-inversion reveals that (1 the Ex-UTLS PV-anomaly induces the westerly winds in the troposphere and the lower stratosphere, including the subtropical jet, that (2 the positive stratospheric PV-anomaly induces the stratospheric polar night jet and that (3 the negative polar cap stratospheric PV-anomaly in summer reduces the westerly wind speeds in the troposphere and induces easterly winds in the stratosphere. The Ex-UTLS PV-anomaly is manifest mainly as an isentropic density- (or mass- anomaly. Piecewise PV-inversion of these anomalies in isolation should account for this by an appropriate adjustment of the lower boundary condition.

  15. Equipment and procedures for ON-SITE testing of PV plants and BIPV

    OpenAIRE

    2014-01-01

    Actual system performance of a PV system can differ from its expected behaviour.. This is the main reason why the performance of PV systems should be monitored, analyzed and, if needed, improved on. Some of the current testing procedures relating to the electrical behaviour of PV systems are appropriated for detecting electrical performance losses, but they are not well-suited to reveal hidden defects in the modules of PV plants and BIPV, which can lead to future losses. This paper reports on...

  16. Power Output Improvement of PV Module for Agricultural Use by Using Inexpensive Sunlight Concentrator

    Institute of Scientific and Technical Information of China (English)

    NISHIMURA Ryo

    2010-01-01

    PV modules are used as stand alone power sources for agricultural equipments such as lifting pumps in farms,where the power infrastructure is not yet improved.In order to expand the agricultural use of PV module,the cost of PV generation should be reduced.In this paper,the power output performance of a commercial PV module was improved by using a sunlight concentrator that could be assembled inexpensively and a simple sun-tracking method.

  17. Best practices for mitigating soiling risk on PV power plants

    KAUST Repository

    AlDowsari, A.

    2015-09-24

    Solar power generates proven, predictable and economical energy and new innovations have made solar PV power plants easy to deploy, integrate and maintain. Areas with large solar energy potential are among the dustiest in the world. At first glance, solar would be a natural fit in many of these environments but humidity, airborne dust, and wind of these regions often bring high soiling rates that can accumulate to reduce performance by up to 10% per month on average, where soiling can be a major loss factor that affects the energy yield for PV plants especially in humid and dusty climates. Therefore, to achieve the desired performance ratio and obtain stable generation, mitigation solutions are proposed to overcome dust issues that affect the performance of PV plants. This makes PV module cleaning a key component for long-term plant performance and sustainable profitability. In this paper, a review of the mechanisms and mitigation solutions to overcome soiling on solar installations using real-world testing and verification is investigated with emphasis on dry type cleaning methods. © 2014 IEEE.

  18. Selecting Solar. Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    This analysis leverages available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  19. Recent advances in PV systems technology development in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Imamura, M.; Grottke, M.; Weiss, I. [WIP Renewable Energies Division, Munich (Germany)

    1995-11-01

    The objectives of the photovoltaics (PV) systems technology development were to study several aspects of plant design, monitoring, control, operation, and management of different types of photovoltaic plants. Unsolved problems were to be identified and analysed, and guidelines to improve the monitoring system were to be developed. Principal studies are summarized.

  20. ECO-TOURISM SUSTAINABILITY THROUGH PV TECHNOLOGY: A COMPREHENSIVE REVIEW

    Directory of Open Access Journals (Sweden)

    ARAVIND C. V

    2013-12-01

    Full Text Available Through the Economic Transformation program the Malaysian Government aims to consider tourism as one of the major contributors to the country’s economy and as an industry that imbibe on the principles of environmental responsibility and sustainable development. The growing challenges in the prevention of expansion in agriculture, forestry and aquaculture, and over-exploitation of the natural resources, have made ecotourism extremely popular as a solution for developing tourism sites. Ecotourism attracts many people who wish not only to explore natural wonders but also to protect them for future generations. Most of the ecotourism sites are presumably situated far from the conventional energy resources and thus transporting electricity to those areas are discussed as inefficient and unsustainable. However, solar Photo-voltaic (PV system is clean and alternative energy to suffice the energy demands of eco-tourist sites. This paper puts statements of the energy demand in global and its impact on the traditional fossil fuels and proposes PV as an alternative renewable technology pertaining to the eco-tourism application. The paper especially focuses on solar PV systems which not only could supply the energy demand of tourist sites but can also maintain the image of the ecotourism. A case of a model lodge is used for the study, through the energy demand analysis. A comprehensive review on the PV architecture is presented that derive interest in the implementation of such structure for the case presented.

  1. Luminescence imaging strategies for drone-based PV array inspection

    DEFF Research Database (Denmark)

    Benatto, Gisele Alves dos Reis; Riedel, Nicholas; Thorsteinsson, Sune

    2017-01-01

    he goal of this work is to perform outdoor defect detection imaging that will be used in a fast, accurate and automatic drone-based survey system for PV power plants. The imaging development focuses on techniques that do not require electrical contact, permitting automatic drone inspections...

  2. PV industry growth and module reliability in Thailand

    Science.gov (United States)

    Chenvidhya, Dhirayut; Seapan, Manit; Sangpongsanont, Yaowanee; Chenvidhya, Tanokkorn; Limsakul, Chamnan; Songprakorp, Roongrojana

    2015-09-01

    The PV applications in Thailand are now installed more than 1.2 GWp cumulatively. It is due to the National Renewable Energy Program and its targets. In the latest Alternative Energy Development Plan (AEDP), the PV electricity production target has increased from 2 GWp to 3 GWp. With this rapid growth, customers and manufacturers seek for module standard testing. So far over one thousands of PV modules per annum have been tested since 2012. The normal tests include type approval test according to TIS standard, acceptance test and testing for local standard development. For type test, the most module failure was found during damp heat test. For annual evaluation test, the power degradation and delamination of power was found between 0 to 6 percent from its nameplate after deployment of 0 to 5 years in the field. For thin-film module, the degradation and delamination was found in range of 0 to 13 percent (about 5 percent on average) from its nameplate for the modules in operation with less than 5 years. However, for the PV modules at the reference site on campus operated for 12 years, the power degradation was ranging from 10 to 15 percent. Therefore, a long term performance assessment needs to be considered to ensure the system reliability.

  3. Comparison of Predictive Models for PV Module Performance (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, B.

    2008-05-01

    This paper examines three models used to estimate the maximum power (P{sub m}) of PV modules when the irradiance and PV cell temperature are known: (1) the power temperature coefficient model, (2) the PVFORM model, and (3) the bilinear interpolation model. A variation of the power temperature coefficient model is also presented that improved model accuracy. For modeling values of P{sub m}, an 'effective' plane-of-array (POA) irradiance (E{sub e}) and the PV cell temperature (T) are used as model inputs. Using E{sub e} essentially removes the effects of variations in solar spectrum and reflectance losses, and permits the influence of irradiance and temperature on model performance for P{sub m} to be more easily studied. Eq. 1 is used to determine E{sub e} from T and the PV module's measured short-circuit current (I{sub sc}). Zero subscripts denote performance at Standard Reporting Conditions (SRC).

  4. Design of fibre reinforced PV concepts for building integrated applications

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Wit, de H.; Boer, de A.

    2009-01-01

    Fibre reinforced polymers present an interesting encapsulation medium for PV-modules. Glass fibres can provide increased strength and stiffness to thin polymer layers overcoming the brittleness and limited deformability of glass-panes. Glass fibre reinforced polymers allows for transparency over a b

  5. Development of white LED based PV lighting systems

    Energy Technology Data Exchange (ETDEWEB)

    Sastry, O.S.; Pant, P.C.; Prasad, G.; Kumar, Rajesh; Bandyopadhyay, Bibek [Solar Energy Centre, Ministry of New and Renewable Energy, Block 14, CGO Complex, Lodhi Road, New Delhi 110003 (India); Kamala Devi, V. [Agency for Non-Conventional Energy and Rural Technology, P.B. No. 1094, Pattom, P.O. Kasavadasapuram, Trivandrum, Kerala 695 004 (India)

    2010-09-15

    A high performance white light emitting diode (WLED) based PV lighting system has been developed under a joint project of SEC and ANERT. The system has been analyzed using the test set-ups developed as a part of advanced lighting laboratory (ALL). The results show that the performance is one of the best among the systems developed in the capacity range. (author)

  6. PV Systems Reliability Final Technical Report: Ground Fault Detection

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    We have examined ground faults in PhotoVoltaic (PV) arrays and the efficacy of fuse, current detection (RCD), current sense monitoring/relays (CSM), isolation/insulation (Riso) monitoring, and Ground Fault Detection and Isolation (GFID) using simulations based on a Simulation Program with Integrated Circuit Emphasis SPICE ground fault circuit model, experimental ground faults installed on real arrays, and theoretical equations.

  7. 5bv.3.21 PV led engine

    DEFF Research Database (Denmark)

    Thorsteinsson, Sune; Poulsen, Peter Behrensdorff; Dam-Hansen, Carsten

    PV-powered lighting systems, light to light systems (L2L), offer outdoor lighting where it is elsewhere cumbersome to enable lighting. Application of these systems at high latitudes, where the difference in day length between summer and winter is large and the solar energy is less requires smart ...

  8. Grid Integration of Large PV Power Systems Using HVDC Link

    Directory of Open Access Journals (Sweden)

    Gamal Sowilam

    2016-09-01

    Full Text Available This paper explores the interconnection of large scale Photo-Voltaic (PV systems to the grid though a High Voltage Direct Current (HVDC link. HVDC link is recently utilized for transmission lines longer than 50 km. It is usually utilized to interconnect two asynchronous grids with the same or different frequencies while avoiding stability disturbances greatly. A suitable Maximum Power Point Tracking (MPPT techniques is employed to control the performance of the integrated PV system. The system of the HVDC link has two 12-pulse converter using thyristor-bridges. The delay and the extinction angles at the rectifier and the inverter units control the flow and the quantity of the transmitted power from the PV system into the grid. Fixed capacitors and filters are used to provide the AC side with the required reactive power and reduce the harmonic contents. For evaluation purposes, different simulation investigations are carried out with a detailed modeling using the MATLAB. These tests corroborate the efficacy of HVDC link for integrating large PV systems to electrical grids.

  9. Silicon Oxynitride Thin Film Barriers for PV Packaging (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    del Cueto, J. A.; Glick, S. H.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2006-10-03

    Dielectric, adhesion-promoting, moisture barriers comprised of silicon oxynitride thin film materials (SiOxNy with various material stoichiometric compositions x,y) were applied to: 1) bare and pre-coated soda-lime silicate glass (coated with transparent conductive oxide SnO2:F and/or aluminum), and polymer substrates (polyethylene terephthalate, PET, or polyethylene napthalate, PEN); plus 2) pre- deposited photovoltaic (PV) cells and mini-modules consisting of amorphous silicon (a-Si) and copper indium gallium diselenide (CIGS) thin-film PV technologies. We used plasma enhanced chemical vapor deposition (PECVD) process with dilute silane, nitrogen, and nitrous oxide/oxygen gas mixtures in a low-power (< or = 10 milliW per cm2) RF discharge at ~ 0.2 Torr pressure, and low substrate temperatures < or = 100(degrees)C, over deposition areas ~ 1000 cm2. Barrier properties of the resulting PV cells and coated-glass packaging structures were studied with subsequent stressing in damp-heat exposure at 85(degrees)C/85% RH. Preliminary results on PV cells and coated glass indicate the palpable benefits of the barriers in mitigating moisture intrusion and degradation of the underlying structures using SiOxNy coatings with thicknesses in the range of 100-200 nm.

  10. Performance enhancement of PV cells through micro-channel cooling

    Directory of Open Access Journals (Sweden)

    Muzaffar Ali

    2015-11-01

    Full Text Available Efficiency of a PV cell is strongly dependent on its surface temperature. The current study is focused to achieve maximum efficiency of PV cells even in scorching temperatures in hot climates like Pakistan where the cell surface temperatures can even rise up to around 80 ℃. The study includes both the CFD and real time experimental investigations of a solar panel using micro channel cooling. Initially, CFD analysis is performed by developing a 3D model of a Mono-Crystalline cell with micro-channels to analyze cell surface temperature distribution at different irradiance and water flow rates. Afterwards, an experimental setup is developed for performance investigations under the real conditions of an open climate of a Pakistan's city, Taxila. Two 35W panels are manufactured for the experiments; one is based on the standard manufacturing procedure while other cell is developed with 4mm thick aluminum sheet having micro-channels of cross-section of 1mm by 1mm. The whole setup also includes different sensors for the measurement of solar irradiance, cell power, surface temperature and water flow rates. The experimental results show that PV cell surface temperature drop of around 15 ℃ is achieved with power increment of around 14% at maximum applied water flow rate of 3 LPM. Additionally, a good agreement is also found between CFD and experimental results. Therefore, that study clearly shows that a significant performance improvement of PV cells can be achieved through the proposed cell cooling technique.

  11. Molecular characterization of Pseudomonas syringae pv. tomato isolates from Tanzania

    DEFF Research Database (Denmark)

    Shenge, K.C.; Stephan, D.; Mabagala, R. B.

    2008-01-01

    pathogenicity assays on tomato, carbon source utilization by the Biolog Microplate system, polymerase chain reaction and restriction fragment length polymorphism (RFLP) analysis. All the P. syringae pv. tomato isolates produced bacterial speck symptoms on susceptible tomato (cv. ‘Tanya') seedlings. Metabolic...

  12. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    . The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed...

  13. Rooftop PV system. PV:BONUS Phase 3B, final technical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Under the PV:BONUS Program, ECD and United Solar developed, demonstrated and commercialized two new lightweight, flexible BIPV modules specifically designed as replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and can be used to address the even larger roofing-replacement market. An important design feature of these modules, which minimizes the installation and balance-of-system costs, is their ability to be installed by conventional roofing contractors without special training. The modules are fabricated from high-efficiency, triple-junction spectrum-splitting a-Si alloy solar cells developed by ECD and United Solar. These cells are produced on thin, flexible stainless steel substrates and encapsulated with polymer materials. The Phase 3 program began in August 1995. The principal tasks and goals of this program, which have all been successfully completed by ECD and United Solar, are described in the body and appendices of this report.

  14. Analytical expression for electrical efficiency of PV/T hybrid air collector

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, Swapnil; Sandhu, G.S.; Tiwari, G.N. [Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016 (India)

    2009-05-15

    The overall electrical efficiency of the photovoltaic (PV) module can be increased by reducing the temperature of the PV module by withdrawing the thermal energy associated with the PV module. In this communication an attempt has been made to develop analytical expression for electrical efficiency of PV module with and without flow as a function of climatic and design parameters. The four different configurations of PV modules are considered for the present study which are defined as; case A (Glass to glass PV module with duct), case B (Glass to glass PV module without duct), case C (Glass to tedlar PV module with duct), case D (Glass to tedlar PV module without duct). Further, experiments were carried out for all configurations under composite climate of New Delhi. It is found that the glass to glass PV modules with duct gives higher electrical efficiency as well as the higher outlet air temperature amongst the all four cases. The annual effect on electrical efficiency of glass to glass type PV module with and without duct is also evaluated. The annual average efficiency of glass to glass type PV module with and without duct is 10.41% and 9.75%, respectively. (author)

  15. PV-θ view of the zonal mean state of the atmosphere

    NARCIS (Netherlands)

    van Delden, A.J.; Hinssen, Y.B.L.

    2012-01-01

    The relation between zonal mean potential vorticity (PV) in potential temperature (u) coordinates and the zonal mean zonal wind in January and in July is studied. PV-anomalies are defined with respect to a reference state that is at rest with respect to the rotating earth. Two important PV-anomalies

  16. Reliability Oriented Design Tool For the New Generation of Grid Connected PV-Inverters

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Cristian; Blaabjerg, Frede; Wang, Huai

    2015-01-01

    This paper introduces a reliability-oriented design tool for a new generation of grid-connected photovoltaic (PV) inverters. The proposed design tool consists of a real field mission profile (RFMP) model (for two operating regions: USA and Denmark), a PV panel model, a grid-connected PV inverter...

  17. Defining Bankability for Each Step of a PV Project Using IECRE

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah

    2016-07-12

    How can a PV customer know whether a PV plant is 'good'? IECRE was created to provide a cost-effective way to identify 'good' PV plants. This presentation describes the motivation, strategy, and status of the IECRE effort as of July, 2016.

  18. A Novel Technique to Obtain the Health of a PV Panel

    DEFF Research Database (Denmark)

    Hussain, Dil Muhammad Akbar; Imran, Raja Muhammad; Shoro, Ghulam Mustafa

    2014-01-01

    Power efficiency delivered from a PV panel individually or as larger system for example a PV Solar Form is very much dependent upon many factors for example irradiance, temperature, shadowing and the health of individual PV panels/cells. The first two factors are typically beyond the control of d...

  19. Methodology for the optimal design of tansformerless grid-connected PV interters

    DEFF Research Database (Denmark)

    Koutroulis, E.; Blaabjerg, Frede

    2012-01-01

    inverter, such that the PV inverter levelised cost of the generated electricity is minimised. The proposed method constitutes a systematic design process, which is capable to explore the impact of the PV inverter configuration on the trade-off between the PV inverter manufacturing cost and the power losses...

  20. Method for Load Sharing and Power Management in a Hybrid PV/Battery Source Islanded Microgrid

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Guerrero, Josep M.

    2016-01-01

    This paper presents a decentralized load sharing and power management method for an islanded microgrid composed of PV units, battery units and hybrid PV/battery units. The proposed method performs all the necessary tasks such as load sharing among the units, battery charging and discharging and PV...

  1. Real Time Photovoltaic Array Simulator for Testing Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sera, Dezso; Valentini, Massimo; Raducu, Alin

    2008-01-01

    In this paper a real time flexible PV array simulator is presented. It is a system that can simulate different PV panel arrays in specific environmental conditions. To evaluate performance of the Maximum Power Point Tracking (MPPT) of grid-connected Photovoltaic (PV) inverters only measurements...

  2. Household photovoltaic market in Xining, Qingha province, China: the role of local PV business

    Energy Technology Data Exchange (ETDEWEB)

    Ling, S.; Boardman, B. [University of Oxford (United Kingdom). Environmental Change Institute; Twidell, J. [University of Reading (United Kingdom). Dept. of Engineering; AMSET Centre, Horninghold (United Kingdom)

    2002-10-01

    This paper assesses the present and future market for household photovoltaic (PV) systems in rural Northwest China, especially from the PV commerce at Xining, Qinghai Province. This unsubsidised free market is now met by the emerging PV industry in China, which includes cell and module manufacturers, and PV system distributors and assemblers. For widespread deployment of such a renewable energy technology, the development of a local free market seems more successful than donor- or 'government subsidy'-driven programmes. Presently, there is a thriving infant PV industry in Northwest China, mostly centred in Xining. Xining-based PV sales companies have extensive networks for selling, marketing and servicing household PV systems for rural farmers and nomads. Small systems are now ordinary items on sale in local shops. Based on interviews and fieldwork observations with seven major PV sales companies in Xining, the household PV market is assessed from the present business operations of these companies. Detail of primary sources is given with the aim of archiving seminal progress in the history of photovoltaic power. The results suggest that although the household PV market will continue to grow, current government and international sponsored PV programmes can create both opportunities and barriers for the infant PV market an industry in China. (author)

  3. DOE Request for Information (RFI) DE-FOA-0000153 PV Manufacturing Initiative

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2010-02-01

    This draft report summarizes the results of the U.S. Department of Energy PV Manufacturing Request for Information (RFI), DE-FOA-0000153, that was released in September 2009. The PV Manufacturing Initiative is intended to help facilitate the development of a strong PV manufacturing industry in the United States.

  4. Large Scale Solar Power Integration in Distribution Grids: PV Modelling, Voltage Support and Aggregation Studies

    NARCIS (Netherlands)

    Samadi, A.

    2014-01-01

    Long term supporting schemes for photovoltaic (PV) system installation have led to accommodating large numbers of PV systems within load pockets in distribution grids. High penetrations of PV systems can cause new technical challenges, such as voltage rise due to reverse power flow during light load

  5. Models for a stand-alone PV system[Photovoltaic

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P.; Hansen, L.H.; Bindner, H.

    2000-12-01

    This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risoe National Laboratory. The work has been supported by the Danish Ministry of Energy, as a part of the activities in the Solar Energy Centre Denmark. The study is carried out at Risoe National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PV system, namely solar cells, battery, controller, inverter and load. The models for PV module and battery are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model (KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program that provides a graphical interface for building models as modular block diagrams. The non-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements. The performance of the best linear Black box model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risoe. (au)

  6. Experimental comparison of PV-smoothing controllers using distributed generators

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Ellis, Abraham; Denda, Atsushi; Morino, Kimio; Hawkins, John N.; Arellano, Brian; Shinji, Takao; Ogata, Takao; Tadokoro, Masayuki

    2014-02-01

    The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

  7. PV-Optitag 2 - 1. phase: Development of CO{sub 2} neutral buildings; PV-Optitag 2 - 1. etape: Udvikling af CO{sub 2} neutrale boliger

    Energy Technology Data Exchange (ETDEWEB)

    Vejsig Pedersen, P.

    2008-04-15

    An integrated PV cell-solar heating roof solution called PV Optitag was developed in close cooperation between architects and engineers to make new CO{sub 2} neutral solutions for urban development projects. A CO{sub 2} neutral rooftop apartment with PV cells in a solar-energy roof exploits an air-based PVT PV-cell solution in combination with a heat pump as well as PV cells integrated into windows. The idea behind the apartment is a zero-energy solution in new buildings or an urban development component, and the apartment has been exhibited in Orestaden, see www.soltag.net. The project gained practical experience in fluid-covered PV cells in combination with heat pumps in housing. (author)

  8. Update of the Dutch PV specific yield for determination of PV contribution to renewable energy production: 25% more energy!

    NARCIS (Netherlands)

    van Sark, Wilfried; Bosselaar, L.; Gerrissen, P.; Esmeijer, K.B.D.; Moraitis, Panagiotis; van den Donker, M.; Emsbroek, G.

    2014-01-01

    Statistics Netherlands (CBS) annually publishes the contribution of renewables to the Dutch electricity supply, by following a national protocol. The amount of electricity generated by photovoltaic (PV) technology is calculated from the average installed capacity in a particular year multiplied by a

  9. Consequences of Reducing the Cost of PV Modules on a PV Wind Diesel Hybrid System with Limited Sizing Components

    Directory of Open Access Journals (Sweden)

    Jones S. Silva

    2012-01-01

    Full Text Available The use of renewable resources for power supply in family homes has passed the stage of utopia to became a reality, with limits set by technical and economic parameters. This paper presents the results of a project originated from the initiative of a middle-class family to achieve energy independence at home. The starting point was the concept of home with “zero energy” in which the total energy available is equal to the energy consumed. The solution devised to meet the energy demand of the residence in question is a PV wind diesel hybrid system connected to the grid, with the possibility of energy storage in batteries and in the form of heating water and the environment of the house. As a restriction, the family requested that the system would represent little impact to the lifestyle and landscape. This paper aims to assess the consequences of reductions in the cost of the PV modules on the optimization space, as conceived by the software Homer. The results show that for this system, a 50% reduction in the cost of PV modules allows all viable solutions including PV modules.

  10. Integrating High Penetrations of PV into Southern California: Year 2 Project Update; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Mather, B.; Neal, R.

    2012-08-01

    Southern California Edison (SCE) is well into a five-year project to install a total of 500 MW of distributed photovoltaic (PV) energy within its utility service territory. Typical installations to date are 1-3 MW peak rooftop PV systems that interconnect to medium-voltage urban distribution circuits or larger (5 MW peak) ground-mounted systems that connect to medium-voltage rural distribution circuits. Some of the PV system interconnections have resulted in distribution circuits that have a significant amount of PV generation compared to customer load, resulting in high-penetration PV integration scenarios. The National Renewable Energy Laboratory (NREL) and SCE have assembled a team of distribution modeling, resource assessment, and PV inverter technology experts in order to investigate a few of the high-penetration PV distribution circuits. Currently, the distribution circuits being studied include an urban circuit with a PV penetration of approximately 46% and a rural circuit with a PV penetration of approximately 60%. In both cases, power flow on the circuit reverses direction, compared to traditional circuit operation, during periods of high PV power production and low circuit loading. Research efforts during year two of the five-year project were focused on modeling the distribution system level impacts of high-penetration PV integrations, the development and installation of distribution circuit data acquisition equipment appropriate for quantifying the impacts of high-penetration PV integrations, and investigating high-penetration PV impact mitigation strategies. This paper outlines these research efforts and discusses the following activities in more detail: the development of a quasi-static time-series test feeder for evaluating high-penetration PV integration modeling tools; the advanced inverter functions being investigated for deployment in the project's field demonstration and a power hardware-in-loop test of a 500-kW PV inverter implementing a

  11. Detecting loss mechanisms of c-Si PV modules in-situ I-V measurement

    Science.gov (United States)

    Guo, Siyu; Schneller, Eric; Walters, Joe; Davis, Kristopher O.; Schoenfeld, Winston V.

    2016-09-01

    PV module reliability is alsways an important issue for PV industry. In an outdoor PV system, PV modules suffer from degradation due to different factors. It is then very important to determine the loss mechanisms of a PV module and making improvement based on this. It is found in this work that due to mismatch effect, using fitting method to extract I-V characteristics might not be well applied on a PV module, especially when it has non-uniform degradation problem. This work proposes a method to accurately quantify the power loss of PV modules due to different degradation mechanisms, including series resistance (Rs) loss, non-uniform shunting loss and number of shunted cells, uniform shunting loss, uniform current loss, non-uniform current (mismatch) loss, recombination current (J01 and J02) losses of a PV module. All required input information are the measured current-voltage (I-V) curves and short circuit current- open circuit voltage (Isc-Voc) of PV module initial state and final state. The method is first applied to a simulated PV module with various degradation problems. Power loss due to each loss mechanism for the simulated PV module is then extracted using the proposed method and a pie chart can be generated. Comparing with the actual power loss on each loss mechanism, the method proposed in this work is proved to be very accurate. The method is then further applied to a degradated PV module istalled in an outdoor PV system. The power loss on series resistance, shunting and current mismatch are effectively identified and the number of shunted cells is accurately calculated. In the real application, this method can be used in both indoor and outdoor characterization, which can be very beneficial for PV degradation analysis of PV modules and systems.

  12. Experimental Study on the Electric and Thermal Performance of PV/T System%PV/T系统电热性能的实验研究

    Institute of Scientific and Technical Information of China (English)

    鲁丹; 吕建

    2012-01-01

    介绍了PV/T系统组成的原理,针对PV/T系统的电热性能进行了实验研究,并对实验数据进行了处理.计算出了不同参数下该PV/T系统的热效率和电效率,分析了这些参数对系统热效率的影响,以及PV/T模块表面温度对系统电效率的影响.

  13. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    Energy Technology Data Exchange (ETDEWEB)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  14. Optimal design of NPC and Active-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    Targeting at a cost-effective deployment of grid-connected PhotoVoltaic (PV) systems, this paper presents a new methodology for the optimal design of transformerless PV inverters, which are based on the Neutral Point Clamped (NPC) and the Active-Neutral Point Clamped (ANPC) topologies. The design...... optimization results demonstrate that a different set of optimal values of the PV inverter switching frequency and output filter components are derived for the NPC and ANPC topologies, respectively, as well as for each of the PV inverter installation sites under study. The NPC and ANPC PV inverter structures...

  15. Residential Solar PV Planning in Santiago, Chile: Incorporating the PM10 Parameter

    Directory of Open Access Journals (Sweden)

    Gustavo Cáceres

    2014-12-01

    Full Text Available This paper addresses an economic study of the installation of photovoltaic (PV solar panels for residential power generation in Santiago, Chile, based on the different parameters of a PV system, such as efficiency. As a performance indicator, the Levelized Cost of Energy (LCOE was used, which indicates the benefit of the facility vs. the current cost of electrical energy. In addition, due to a high level of airborne dusts typically associated with PM10, the effect of the dust deposition on PV panels’ surfaces and the effect on panel performance are examined. Two different scenarios are analyzed: on-grid PV plants and off-grid PV plants.

  16. Effect of Reactive Power Management of PV Inverters on Need for Energy Storage

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Yang, Guangya

    2013-01-01

    Grid connected Photovoltaic (PV) systems are among the increasingly growing electric power generation units worldwide. The majority of new installations are expected to be residential PVs that are connected into distribution systems. However, the PV hosting capacity of low voltage (LV) grids...... is limited due to the voltage rise at the point of connection associated with the PV feed-in current. Reactive power management using PV inverters and using the electrical energy storage systems (EESS) are amongst the main solutions for increasing the PV hosting capacity in LV grids. In this paper, a method...

  17. Very Thin Flexible Coupled Inductors for PV Module Integrated GaN Converter

    DEFF Research Database (Denmark)

    Acanski, Milos; Ouyang, Ziwei; Popovic-Gerber, Jelena;

    2012-01-01

    As the PV energy penetrates into the urban area, shortcomings of the conventional centralized PV system architectures become more pronounced under the influence of urban environment with shading, soiling and orientation mismatch issues. To overcome these limitations new PV system architectures were...... proposed with more granular power processing by means of distributed maximum power point tracking (DMPPT). This is achieved by adjoining a MPPT unit to each PV module in the PV array. This paper presents a step further in the distributed power tracking approach, with a concept of very low profile power...

  18. PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Valentini, Massimo;

    2008-01-01

    This paper concerns the evaluation of performance of grid-connected PV inverters in terms of conversion efficiency, European efficiency, static and dynamic MPP efficiency. Semi-automated tests were performed in the PV laboratory of the Institute of Energy Technology at the Aalborg University...... (Denmark) on a commercial transformerless PV inverter. Thanks to the available experimental test setups, that provide the required high measuring accuracy, and the developed PV simulator, which is required for MPPT performance evaluation, PV Inverters can be pretested before being tested by accredited...

  19. A Novel Frequency Restoring Strategy of Hydro-PV Hybrid Microgrid

    DEFF Research Database (Denmark)

    Wei, Feng; Kai, Sun; Guan, Yajuan

    2014-01-01

    The conventional PV systems based on the voltage inverters only inject dispatched power to the utility grid when they work at a grid-connected mode in the hydro-PV hybrid microgrid. Due to the droop method employed for load sharing between generators, as well as the enormous inertia of system....... The existence of frequency steady-state error and the slow active power/frequency dynamic response are inevitable. Therefore, a novel frequency restoring strategy for the hydro-PV hybrid microgrid based on the improved hierarchical control of PV systems is proposed in this paper. The output active power of PV...

  20. Solar Photovoltaic Economic Development: Building and Growing a Local PV Industry, August 2011 (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2011-08-01

    The U.S. photovoltaic (PV) industry is forecast to grow, and it represents an opportunity for economic development and job creation in communities throughout the United States. This report helps U.S. cities evaluate economic opportunities in the PV industry. It serves as a guide for local economic development offices in evaluating their community?s competitiveness in the solar PV industry, assessing the viability of solar PV development goals, and developing strategies for recruiting and retaining PV companies to their areas.

  1. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    Directory of Open Access Journals (Sweden)

    Tamer Khatib

    2012-01-01

    Full Text Available This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN, optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based model for metrological prediction uses four meteorological variables, namely, sun shine ratio, day number and location coordinates. As for PV system sizing, iterative methods are used for determining the optimal sizing of three types of PV systems, which are standalone PV system, hybrid PV/wind system and hybrid PV/diesel generator system. The loss of load probability (LLP technique is used for optimization in which the energy sources capacities are the variables to be optimized considering very low LLP. As for determining the optimal PV panels tilt angle and inverter size, the Liu and Jordan model for solar energy incident on a tilt surface is used in optimizing the monthly tilt angle, while a model for inverter efficiency curve is used in the optimization of inverter size.

  2. How PV system ownership can impact the market value of residential homes

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jamie L. [Energy Sense Finance, LLC, Punta Gorda, FL (United States)

    2014-01-01

    There are multiple ways for a homeowner to obtain the electricity generating and savings benefits offered by a photovoltaic (PV) system. These include purchasing a PV system through various financing mechanisms, or by leasing the PV system from a third party with multiple options that may include purchase, lease renewal or PV system removal. The different ownership options available to homeowners presents a challenge to appraisal and real estate professionals during a home sale or refinance in terms of how to develop a value that is reflective of the PV systems operational characteristics, local market conditions, and lender and underwriter requirements. This paper presents these many PV system ownership options with a discussion of what considerations an appraiser must make when developing the contributory value of a PV system to a residential property.

  3. Scalable Optimization Methods for Distribution Networks with High PV Integration

    Energy Technology Data Exchange (ETDEWEB)

    Guggilam, Swaroop S.; Dall' Anese, Emiliano; Chen, Yu Christine; Dhople, Sairaj V.; Giannakis, Georgios B.

    2016-07-01

    This paper proposes a suite of algorithms to determine the active- and reactive-power setpoints for photovoltaic (PV) inverters in distribution networks. The objective is to optimize the operation of the distribution feeder according to a variety of performance objectives and ensure voltage regulation. In general, these algorithms take a form of the widely studied ac optimal power flow (OPF) problem. For the envisioned application domain, nonlinear power-flow constraints render pertinent OPF problems nonconvex and computationally intensive for large systems. To address these concerns, we formulate a quadratic constrained quadratic program (QCQP) by leveraging a linear approximation of the algebraic power-flow equations. Furthermore, simplification from QCQP to a linearly constrained quadratic program is provided under certain conditions. The merits of the proposed approach are demonstrated with simulation results that utilize realistic PV-generation and load-profile data for illustrative distribution-system test feeders.

  4. Selecting Solar: Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    Before investing in a system, a prospective PV customer must not only have initial concept 'buy in,' but also be able to evaluate the tradeoffs associated with different system parameters. Prospective customers might need to evaluate disparate costs for each system attribute by comparing multiple bids. The difficulty of making such an evaluation with limited information can create a cognitive barrier to proceeding with the investment. This analysis leverages recently available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  5. High-Penetration PV Integration Handbook for Distribution Engineers

    Energy Technology Data Exchange (ETDEWEB)

    Seguin, Rich [Electrical Distribution Design, Blacksburg, VA (United States); Woyak, Jeremy [Electrical Distribution Design, Blacksburg, VA (United States); Costyk, David [Electrical Distribution Design, Blacksburg, VA (United States); Hambrick, Josh [Electrical Distribution Design, Blacksburg, VA (United States); Mather, Barry [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-01

    This handbook has been developed as part of a five-year research project which began in 2010. The National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed together to analyze the impacts of high-penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to leverage the experience that SCE and the project team would gain during the significant installation of 500 MW of commercial scale PV systems (1-5 MW typically) starting in 2010 and completing in 2015 within SCE’s service territory through a program approved by the California Public Utility Commission (CPUC).

  6. Reliability Assessment of Transformerless PV Inverters considering Mission Profiles

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2015-01-01

    Full Text Available Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved by either modifying the modulation schemes or adding extra power switching devices, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redistributed and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature. The mission profile is translated to device thermal loading, which is used for lifetime prediction. Comparison results reveal the lifetime mismatches among the power switching devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency.

  7. Reliability Assessment of Transformerless PV Inverters Considering Mission Profiles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2015-01-01

    , resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redis-tributed, and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device......Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved either by modifying the modulation schemes or adding extra power switching devices...... devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency....

  8. Models for a stand-alone PV system

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Hansen, L.H.;

    2001-01-01

    Energy Centre Denmark. The study is carried out at Risø National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PVsystem, namely solar cells, battery, controller, inverter and load. The models for PV module and battery...... that provides a graphical interface for building models as modular block diagrams. Thenon-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements....... The performance of the best linear Blackbox model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risø....

  9. Quantify Degradation Rates and Mechanisms of PV Modules and Systems Installed in Florida Through Comprehensive Experimental and Theoretical Analysis (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Sorloaica-Hickman, N.; Davis, K.; Kurtz, S.; Jordan, D.

    2011-02-01

    The economic viability of photovoltaic (PV) technologies is inextricably tied to both the electrical performance and degradation rate of the PV systems, which are the generators of electrical power in PV systems. Over the past 15 years, performance data have been collected on numerous PV systems installed throughout the state of Florida and will be presented.

  10. Pseudomonas syringae pv. tabaci in papaya seedlings Pseudomonas syringae pv. tabaci em plântulas de mamoeiro

    Directory of Open Access Journals (Sweden)

    Luís Otávio S. Beriam

    2006-03-01

    Full Text Available The natural occurrence of Pseudomonas syringae pv. tabaci causing leaf spot symptoms in papaya seedlings is reported. The pathogen was identified through biochemical, physiological, serological, and molecular assays and artificial inoculations in papaya plants. It was also shown that the strains were pathogenic to bean and tobacco plants. The restriction patterns obtained with Afa I, Alu I, Dde I, Hae III, Hpa II, Hinf I, Sau 3A I and Taq I of the PCR-RFLP of 16S-23S DNAr were identical to the P. s. pv. tabaci patterns. Primers corresponding to hrpL gene of P. syringae were also tested and the results grouped the papaya strains with P s. pv. tabaci. Bacterial strains were deposited at Coleção de Culturas IBSBF, Instituto Biológico, Campinas, Brazil, under access numbers 1687 and 1822.É relatada a ocorrência natural de Pseudomonas syringae pv. tabaci causando sintomas de lesões foliares em plântulas de mamoeiro. O patógeno foi identificado por meio de testes bioquímicos, fisiológicos, serológicos e moleculares, além de ensaios de patogenicidade em plantas de mamoeiro, feijoeiro e fumo. Os padrões de restrição obtidos com as enzimas Afa I, Alu I, Dde I, Hae III, Hpa II, Hinf I, Sal 3A I e Taq I, utilizando-se a técnica de PCR-RLFP da região espaçadora 16S-23S do DNA ribossômico, foram idênticos àqueles apresentados para P. s. pv. tabaci. Primers correspondentes ao gene hrpL de P. syringae foram também testados e os resultados obtidos permitiram agrupar as linhagens isoladas de mamão com P. s. pv. tabaci. Linhagens bacterianas estão depositadas na coleção de culturas IBSBF, Instituto Biológico, Campinas, sob n. 1687 e 1822.

  11. Pv rural electrification programme at the Bolivian high plateau

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzo, E.; Aguilera, J. [Instituto de Energia Solar, ETSI Telecomunicacion, (Spain)

    1995-12-31

    Since 1988 the Institute of Solar Energy of the Universidad Politecnica de Madrid is carrying out a pv rural electrification programme at the Bolivian high plateau. This programme has been focused in three aspects: the domestic electrification, users participation and transfer technology. At present, there are about 1,500 electrified dwellings distributed in the Bolivian high plateau. We have got deep knowledge about life style and organization of the aymara Indians who are the inhabitants of the working zone. We think that this knowledge can be very useful for a large scale introduction of PV solar energy in this region. Finally, we present a new way to transfer PV technology to developing countries. Thanks to this programme a group of aymara Indians is able to manufacture charge regulators and electronic ballast to use in the PV installations of the programme. [Espanol] Desde 1988 el Instituto de Energia Solar de la Universidad Politecnica de Madrid esta llevando a cabo un programa fotovoltaico de electrificacion rural en la altiplanicie Boliviana. Este programa ha sido enfocado a tres aspectos: la electrificacion domestica, la participacion de los usuarios y la transferencia de la tecnologia. Actualmente, hay alrededor de 1500 conjuntos habitacionales electrificados distribuidos en la altiplanicie Boliviana. Hemos obtenido un profundo conocimiento del estilo de vida y de la organizacion de los indios aymara que son los habitantes de la zona de trabajo. Pensamos que este conocimiento puede ser muy util para una introduccion en gran escala de la energia solar fotovoltaica en esta region. Finalmente, presentamos una nueva forma de transferir la tecnologia fotovoltaica a paises en desarrollo. Gracias a este programa un grupo de indios aymara pueden fabricar reguladores de carga y balastros electronicos para ser usados en instalaciones fotovoltaicas del programa.

  12. Assessment of genetic diversity of Xanthomonas oryzae pv. oryzae

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@Bacterial blight of rice, caused by Xanthomonas oryzae pv. Oryzae(Xoo. ), is one of the major rice diseases in China. Making clear the shift of genetic diversity of the pathogen will provide important information for rice breeding. Strains collected from 11 provinces located in Southern region of the Changjiang River in China were assessed by using inoculation method and IS-PCR(Insertion Sequence-Based Polymerase Chain Reaction) analysis.

  13. High Penetration PV: How High Can We Go?

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-01

    Brochure highlighting NREL's partnership with SolarCity and Hawaiian Electric (HECO) to increase the penetration of solar photovoltaics on the electricity grid. To better understand the potential impact of transient overvoltages due to load rejection, NREL collaborated with SolarCity and HECO to run a series of tests measuring the magnitude and duration of load rejection overvoltage events and demonstrating the ability of advanced PV inverters to mitigate their impacts.

  14. On the Impact of Partial Shading on PV Output Power

    DEFF Research Database (Denmark)

    Sera, Dezso; Baghzouz, Yahia

    2008-01-01

    It is a well-documented fact that partial shading of a photovoltaic array reduces it output power capability. However, the relative amount of such degradation in energy production cannot be determined in a straight forward manner, as it is often not proportional to the shaded area. This paper...... is illustrated by measurements on a commercial 70 W panel, and a 14.4 kW PV array....

  15. Sizing PV-wind hybrid energy system for lighting

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2012-09-01

    Full Text Available Sizing of wind and photovoltaic generators ensures lower operational costs and therefore, is considered as an important issue. An approach for sizing along with a best management technique for a PV-wind hybrid system with batteries is proposed in this paper, in which the best size for every component of the system could be optimized according to the weather conditions and the load profile. The average hourly values for wind speed and solar radiation for Izmir, Turkey has been used in the design of the systems, along with expected load profile. A hybrid power model is also developed for battery operation according to the power balance between generators and loads used in the software, to anticipate performances for the different systems according to the different weather conditions. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Using proposed procedure, a 1.2 kWp PV-wind hybrid system was designed for Izmir, and simulated and measured results are presented.

  16. Predicatbility of windstorm Klaus; sensitivity to PV perturbations

    Science.gov (United States)

    Arbogast, P.; Maynard, K.

    2010-09-01

    It appears that some short-range weather forecast failures may be attributed to initial conditions errors. In some cases it is possible to anticipate the behavior of the model by comparison between observations and model analyses. In the case of extratropical cyclone development one may qualify the representation of the upper-level precursors described in terms of PV in the initial conditions by comparison with either satellite ozone or water-vapor. A step forward has been made in developing a tool based upon manual modifications of dynamical tropopause (i.e. height of 1.5 PV units) and PV inversion. After five years of experimentations it turns out that the forecasters eventually succeed in improving the forecast of some strong cyclone development. However the present approach is subjective per se. To measure the subjectivity of the procedure a set of 15 experiments has been performed provided by 7 different people (senior forecasters and scientists involved in dynamical meteorology) in order to improve an initial state of the global model ARPEGE leading to a poor forecast of the wind storm Klaus (24 January 2009). This experiment reveals that the manually defined corrections present common features but also a large spread.

  17. A Variable PV Broad Absorption Line and Quasar Outflow Energetics

    CERN Document Server

    Capellupo, Daniel M; Barlow, Tom A

    2014-01-01

    Broad absorption lines (BALs) in quasar spectra identify high velocity outflows that might exist in all quasars and could play a major role in feedback to galaxy evolution. The viability of BAL outflows as a feedback mechanism depends on their kinetic energies, as derived from the outflow velocities, column densities, and distances from the central quasar. We estimate these quantities for the quasar, Q1413+1143 (redshift $z_e = 2.56$), aided by the first detection of PV $\\lambda\\lambda$1118,1128 BAL variability in a quasar. In particular, PV absorption at velocities where the CIV trough does not reach zero intensity implies that the CIV BAL is saturated and the absorber only partially covers the background continuum source (with characteristic size 22.3 (cm^-2). Variability in the PV and saturated CIV BALs strongly disfavors changes in the ionization as the cause of the BAL variability, but supports models with high-column density BAL clouds moving across our lines of sight. The observed variability time of ...

  18. Rooftop PV system. Final technical progress report, Phase II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    Under this four-year PV:BONUS Program, ECD and United Solar are developing and demonstrating two new lightweight flexible building integrated Photovoltaic (BIPV) modules specifically designed as exact replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and address the even larger roofing replacement market. The modules are designed to be installed by roofing contractors without special training which minimizes the installation and balance of system costs. The modules will be fabricated from high-efficiency, multiple-junction a-Si alloy solar cells developed by ECD and United Solar. Under the Phase I Program, which ended in March 1994, we developed two different concept designs for rooftop PV modules: (1) the United Solar overlapping (asphalt shingle replacement) shingle-type modules and (2) the ECD metal roof-type modules. We also developed a plan for fabricating, testing and demonstrating these modules. Candidate demonstration sites for our rooftop PV modules were identified and preliminary engineering designs for these demonstrations were developed; a marketing study plan was also developed. The major objectives of the Phase II Program, which started in June 1994 was (1) to develop, test, and qualify these new rooftop modules; (2) to develop mechanical and electrical engineering specifications for the demonstration projects; and (3) to develop a marketing/commercialization plan.

  19. Comparative Study Between Wind and Photovoltaic (PV) Systems

    Science.gov (United States)

    Taha, Wesam

    This paper reviews two renewable energy systems; wind and photovoltaic (PV) systems. The common debate between the two of them is to conclude which one is better, in terms of cost and efficiency. Therefore, comparative study, in terms of cost and efficiency, is attempted. Regarding total cost of both, wind and PV systems, many parameters must be taken into consideration such as availability of energy (either wind or solar), operation and maintenance, availability of costumers, political influence, and the components used in building the system. The main components and parameters that play major role in determining the overall efficiency of wind systems are the wind turbine generator (WTG), gearbox and control technologies such as power, and speed control. On the other hand, in grid-connected PV systems (GCPVS), converter architecture along with maximum power point tracking (MPPT) algorithm and inverter topologies are the issues that affects the efficiency significantly. Cost and efficiency analyses of both systems have been carried out based on the statistics available till today and would be useful in the progress of renewable energy penetration throughout the world.

  20. Modeling and Simulation for Hybrid of PV-Wind system

    Directory of Open Access Journals (Sweden)

    Maged N. F. Nashed

    2015-04-01

    Full Text Available The rising consumption rate of fossil fuels causes a significant pollution impact on the atmosphere, unwanted greenhouse gases has drawn worldwide attention towards renewable energy sources. Moreover, in recent year’s generation of electricity using the different types of renewable sources are specifically evaluated in the economical performance of the overall equipment. This paper focuses on the modeling and analysis of a Standalone Photovoltaic (PV- wind energy hybrid generation system under different conditions using MATLAB. The proposed system consists of two renewable sources i.e. wind and solar energy. Modeling of PV array and wind turbine is explained. The wind subsystem is equipped of an induction generator. In photovoltaic system, the variable DC output voltage is controlled using buck-boost converter for the MPPT. These two systems are combined to operate in parallel and the common bus collects the total energy from the wind and PV systems are uses it to the load and with change the load

  1. Pv rural electrification in Kiribati: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Hurry, Suresh [Energy and Atmosphere Programme, SEED/BPPS UNDP, New York (United States)

    1995-12-31

    In collaboration with the Japan International Cooperation Agency (JICA), United Nations Development Programme (UNDP) participated in the implementation of a photovoltaic (PV) rural electrification project in Kiribati. Under this project, assistance was provided to the Kiribati Solar Energy Company (SEC) in order to enable it to provide electricity service as a micro utility in a effective manner. The assistance provided included installation of 55 PV-based solar home systems and one community system. In addition, the assistance focussed on technical training of SEC personnel on PV systems and management training on accounting, billing, spare parts inventory, etcetera. [Espanol] En colaboracion con la Japan International Cooperation Agency (JICA), el Programa de las Naciones Unidas para el Desarrollo (PNUD) participo en la puesta en practica de un proyecto de electrificacion rural fotovoltaico en Kiribati. Dentro de este proyecto, se proporciono ayuda a la Kiribati Solar Energy Company (SEC) para ponerla en condicion de suministrar el servicio electrico, en una forma efectiva, como una micro empresa electrica. La ayuda proporcionada incluyo la instalacion de 55 sistemas domesticos solares fotovoltaicos y un sistema comunitario. Adicionalmente, la ayuda se enfoco al entrenamiento tecnico del personal de SEC en sistemas fotovoltaicos y en el entrenamiento administrativo en contabilidad, facturacion, inventariado de partes de repuesto, etc.

  2. Overcoming PV grid issues in the urban areas

    Energy Technology Data Exchange (ETDEWEB)

    Ehara, T.

    2009-10-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at grid issues in urban photovoltaic electricity and how to overcome them. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy as a significant and sustainable renewable energy option. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the goal of mainstreaming PV systems in the urban environment. In this report, PV grid interconnection issues and countermeasures based on the latest studies are identified and summarised. Appropriate and understandable information is provided for all possible stakeholders. Possible impacts and benefits of PV grid interconnection are identified, technical measures designed to eliminate negative impacts and enhance possible benefits are presented. The status of research and demonstration projects is introduced and the latest outcomes are summarised. Recommendations and conclusions based on the review process are summarised and presented.

  3. Molecular detection of Xanthomonas oryzae pv.oryzae, Xanthomonas oryzae pv. oryzicola, and Burkholderia glumae in infected rice seeds and leaves

    Institute of Scientific and Technical Information of China (English)

    Wen; Lu; Luqi; Pan; Haijun; Zhao; Yulin; Jia; Yanli; Wang; Xiaoping; Yu; Xueyan; Wang

    2014-01-01

    The polymerase chain reaction(PCR) is particularly useful for plant pathogen detection. In the present study, multiplex PCR and SYBR Green real-time PCR were developed to facilitate the simultaneous detection of three important rice pathogens, Xanthomonas oryzae pv.oryzae, X. oryzae pv. oryzicola, and Burkholderia glumae. The unique PCR primer sets were designed from portions of a putative glycosyltransferase gene of X. oryzae pv. oryzae, an Avr Rxo gene of X. oryzae pv. oryzicola, and an internal transcribed spacer(ITS) sequence of B. glumae. Using a multiplex PCR assay, X. oryzae pv. oryzae, X. oryzae pv. oryzicola, and B. glumae were detected in one PCR reaction that contained the newly developed primer set mix. Using SYBR Green real-time PCR assays, X. oryzae pv. oryzae, X. oryzae pv. oryzicola, and B. glumae were detected at 1, 1, and 10 fg μL-1, respectively. These newly designed molecular assays are sensitive and could be reliable tools for pathogen detection and disease forecasting.

  4. Quantification, challenges and outlook of PV integration in the power system: a review by the European PV Technology Platform

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Baccaro, Federica; De Felice, Matteo;

    2015-01-01

    Integration in the power system has become a limiting factor to the further development of photovoltaics. Proper quantification is needed to evaluate both issues and solutions; the share of annual electricity demand is widely used but we found that some of the metrics which are related to power...... rather than energy better reflect the impact on networks. Barriers to wider deployment of PV into power grids can be split between local technical issues (voltage levels, harmonics distortion, reverse power flows and transformer loading) and system-wide issues (intermittency, reduction of system...... networks. Forecasting, storage, and combination with other renewable sources are interdependent solutions to solve the intermittency issue. Finally, we found that PV is also an opportunity to reduce some investment required to upgrade existing power networks. Through integration with micro-grids and hybrid...

  5. Quantification, challenges and outlook of PV integration in the power system: a review by the European PV Technology Platform

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Baccaro, Federica; De Felice, Matteo;

    2015-01-01

    rather than energy better reflect the impact on networks. Barriers to wider deployment of PV into power grids can be split between local technical issues (voltage levels, harmonics distortion, reverse power flows and transformer loading) and system-wide issues (intermittency, reduction of system......Integration in the power system has become a limiting factor to the further development of photovoltaics. Proper quantification is needed to evaluate both issues and solutions; the share of annual electricity demand is widely used but we found that some of the metrics which are related to power...... networks. Forecasting, storage, and combination with other renewable sources are interdependent solutions to solve the intermittency issue. Finally, we found that PV is also an opportunity to reduce some investment required to upgrade existing power networks. Through integration with micro-grids and hybrid...

  6. Antagonism of Bacillus spp. against Xanthomonas campestris pv. campestris

    Directory of Open Access Journals (Sweden)

    Leila Monteiro

    2005-01-01

    Full Text Available The antagonism of eight Bacillus isolates was investigated against nine strains of Xanthomonas campestris pv. campestris (causal agent of crucifers black rot to assess the role of lipopeptides in this process. Antimicrobial and hemolytic (surfactant activity tests were performed in vitro using agar diffusion methods. Antibiosis and hemolysis were positive for four Bacillus isolates against all X. campestris pv. campestris strains. The correlation observed between antimicrobial and hemolytic activities indicated that lipopeptides were involved in the antibiosis mechanism of the studied antagonists. Fermentation studies were carried out with the isolates that showed highest antimicrobial and hemolytic activities, to follow up growth and production of bioactive and surfactant compounds. Production of bioactive and surfactant compounds was observed during the late growth phase of the Bacillus isolates.Investigação sobre o antagonismo de oito isolados de Bacillus: B. subtilis R14, B. megaterium pv. cerealis RAB7, B. megaterium pv. cerealis C211, B. megaterium C116, Bacillus sp. RAB9, B. cereus C240, Bacillus sp. C11 e B. cereus C210, contra nove linhagens de X. campestris pv. campestris (bactéria responsável pela podridão negra das crucíferas foi realizada para se verificar a participação de lipopeptídeos neste mecanismo. Testes de atividades antimicrobiana e hemolítica (surfactante foram realizados, utilizando-se o método de difusão em ágar. Antibiose e hemólise foram positivas para quatro isolados de Bacillus: R14, RAB7, C116 e C210. A correlação observada entre as atividades antimicrobiana e a hemolítica indica que lipopeptídeos estão envolvidos no mecanismo de antibiose dos isolados investigados. As fermentações foram realizadas com os isolados que demonstraram melhores resultados nos testes de atividades antimicrobiana e hemolítica: R14, RAB7 e C116, para acompanhar o crescimento e a produção de compostos bioativos e

  7. Investigation of the Effect Temperature on Photovoltaic (PV Panel Output Performance

    Directory of Open Access Journals (Sweden)

    Amelia Razak

    2016-10-01

    Full Text Available The main limit of PV systems is the low conversion efficiency of PV panels, which is strongly influenced by their operating temperature. Lack of accuracy in consideration through PV panel temperature increases the financial risk of system installation. This present study investigates the effects of operating temperature on monocrystalline PV panel at Perlis, Malaysia. A selected model of PV panel firstly was simulated using PVSYST software in order to evaluate its output performance. Meanwhile, PROVA 200 used to measure and record all electrical data for outdoor experimental during the sunniest day. Besides, the thermal distribution was analysed through PV panel temperatures and thermal imaging. Simulation results implied that the output power of PV panel decreases with increasing of its working temperature followed by the efficiency. The experimental results obviously show that the STC parameters do not represent the real operating conditions of PV panel for outdoor conditions. Less output power was produced affected by the atmospheric factors such as solar irradiance and ambient temperature. These both factors strongly affected the PV panel temperature distribution. In short, the elevating of PV panel temperature contributed to the negative impact on output performance of the panel.

  8. EcPV2 DNA in equine genital squamous cell carcinomas and normal genital mucosa.

    Science.gov (United States)

    Bogaert, Lies; Willemsen, Anouk; Vanderstraeten, Eva; Bracho, Maria A; De Baere, Cindy; Bravo, Ignacio G; Martens, Ann

    2012-07-01

    Squamous cell carcinoma (SCC) represents the most common genital malignant tumor in horses. Similar to humans, papillomaviruses (PVs) have been proposed as etiological agents and recently Equine papillomavirus type 2 (EcPV2) has been identified in a subset of genital SCCs. The goals of this study were (1) to determine the prevalence of EcPV2 DNA in tissue samples from equine genital SCCs, penile intraepithelial neoplasia (PIN) and penile papillomas, using EcPV2-specific PCR, (2) to examine the prevalence of latent EcPV2 infection in healthy genital mucosa and (3) to determine genetic variability within EcPV2 and to disentangle phylogenetic relationships of EcPV2 among PVs. EcPV2 DNA was detected in all but one penile SCC (15/16), in all PIN lesions (8/8) and penile papillomas (4/4). Additionally, EcPV2 DNA was demonstrated in one of two metastasized lymph nodes, one contact metastasis in the mouth, two vaginal and one anal lesion. In healthy horses, EcPV2 DNA was detected in 10% (4/39) of penile swabs but in none of vulvovaginal swabs (0/20). This study confirms the presence of EcPV2 DNA in equine genital SCCs and shows its involvement in anal lesions, a lymph node and contact metastases. Latent EcPV2 presence was also shown in normal male genital mucosa. We found that different EcPV2 variants cocirculate among horses and that EcPV2 is related to the Delta+Zeta PVs and is only a very distant relative of high-risk human PVs causing genital cancer. Thus, similar viral tropism and similar malignant outcome of the infection do not imply close evolutionary relationship.

  9. An aquaporin PvTIP4;1 from Pteris vittata may mediate arsenite uptake.

    Science.gov (United States)

    He, Zhenyan; Yan, Huili; Chen, Yanshan; Shen, Hongling; Xu, Wenxiu; Zhang, Haiyan; Shi, Lei; Zhu, Yong-Guan; Ma, Mi

    2016-01-01

    The fern Pteris vittata is an arsenic hyperaccumulator. The genes involved in arsenite (As(III)) transport are not yet clear. Here, we describe the isolation and characterization of a new P. vittata aquaporin gene, PvTIP4;1, which may mediate As(III) uptake. PvTIP4;1 was identified from yeast functional complement cDNA library of P. vittata. Arsenic toxicity and accumulating activities of PvTIP4;1 were analyzed in Saccharomyces cerevisiae and Arabidopsis. Subcellular localization of PvTIP4;1-GFP fusion protein in P. vittata protoplast and callus was conducted. The tissue expression of PvTIP4;1 was investigated by quantitative real-time PCR. Site-directed mutagenesis of the PvTIP4;1 aromatic/arginine (Ar/R) domain was studied. Heterologous expression in yeast demonstrates that PvTIP4;1 was able to facilitate As(III) diffusion. Transgenic Arabidopsis showed that PvTIP4;1 increases arsenic accumulation and induces arsenic sensitivity. Images and FM4-64 staining suggest that PvTIP4;1 localizes to the plasma membrane in P. vittata cells. A tissue location study shows that PvTIP4;1 transcripts are mainly expressed in roots. Site-directed mutation in yeast further proved that the cysteine at the LE1 position of PvTIP4;1 Ar/R domain is a functional site. PvTIP4;1 is a new represented tonoplast intrinsic protein (TIP) aquaporin from P. vittata and the function and location results imply that PvTIP4;1 may be involved in As(III) uptake.

  10. Characterisation of Si-crystalline PV modules by artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Almonacid, F.; Rus, C.; Hontoria, L.; Fuentes, M.; Nofuentes, G. [Grupo Investigacion y Desarrollo en Energia Solar y Automatica, Dpto. de Ingenieria Electronica y Automatica, E.P.S. Jaen, Universidad de Jaen, Despacho B-110-AB, C vertical stroke Alfoso X El Sabio n 28, 23071 Linares (Jaen) (Spain)

    2009-04-15

    In the photovoltaic field, manufacturers provide ratings for PV modules for conditions referred to as standard test conditions (STC). However, these conditions rarely occur outdoors, so the usefulness and applicability of the indoors' characterisation in standard test conditions of PV modules are a controversial issue. Therefore, to carry out photovoltaic engineering well, a suitable characterisation of PV module electrical behaviour (V-I curves) is necessary. The IDEA Research Group from Jaen University has developed a method based on artificial neural networks (ANNs) to electrical characterisation of PV modules. An ANN has been developed which is able to generate V-I curves of Si-crystalline PV modules for any irradiance and module cell temperature. The results show that the proposed ANN introduces a good accurate prediction for Si-crystalline PV modules' performance when compared with the measured values. (author)

  11. Optimal Planning Strategy for Large PV/Battery System Based on Long-Term Insolation Forecasting

    Science.gov (United States)

    Yona, Atsushi; Uchida, Kosuke; Senjyu, Tomonobu; Funabashi, Toshihisa

    Photovoltaic (PV) systems are rapidly gaining acceptance as some of the best alternative energy sources. Usually the power output of PV system fluctuates depending on weather conditions. In order to control the fluctuating power output for PV system, it requires control method of energy storage system. This paper proposes an optimization approach to determine the operational planning of power output for PV system with battery energy storage system (BESS). This approach aims to obtain more benefit for electrical power selling and to smooth the fluctuating power output for PV system. The optimization method applies genetic algorithm (GA) considering PV power output forecast error. The forecast error is based on our previous works with the insolation forecasting at one day ahead by using weather reported data, fuzzy theory and neural network(NN). The validity of the proposed method is confirmed by the computer simulations.

  12. Determining the maximum feasible amount of photovoltaics in the European transmission grid under optimal PV utilization

    Energy Technology Data Exchange (ETDEWEB)

    Cherevatskiy, Stanislav; Troester, Eckehard [Energynautics GmbH, Langen (Germany)

    2012-07-01

    In the past few years a significant growth of the number of photovoltaic (PV) systems has been observed worldwide and particularly in Europe. Increasing maturity of this technology and growing manufacturing capacities have led to a considerable decline in prices. Looking at a future possible development of installed PV capacities in Europe, the paper at hand investigates how well the available PV energy is made use of when the installed capacity of PV reaches nearly 2000 gigawatt-peak (GWp). A methodology is presented that aims at optimal placement of PV plants taking into consideration region-specific irradiation conditions in Europe and restrictions imposed by the transmission network. Additionally, a mehtod for optimized placement and dimensioning of storage systems along with their best possible operation strategy is applied for assessment of the effect on PV utilization. (orig.)

  13. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  14. Statistical overview of findings by IR-inspections of PV-plants

    Science.gov (United States)

    Buerhop, Claudia; Pickel, Tobias; Scheuerpflug, Hans; Camus, Christian; Hauch, Jens; Brabec, Christoph J.

    2016-09-01

    First statistical evaluation of IR-inspections of PV-plants reveals that 86% of the installed PV-plants show IR-abnormalities. More than 120 PV-plants with more than 160,000 PV-modules were inspected and evaluated statistically. Main IR-abnormalities or failures in modules and string installations are analyzed, respectively. The average failure rate for PV-modules is about 8% and for module strings approximately 4%. The differentiation between the installation locations reveals that small residential installation show relatively more defective modules than large field installations. - Therefore, IR-imaging is a valuable method to give fast and reliable information about the actual quality and failure rate in inspected PV-installations.

  15. Research Status and Solution for Photovoltaic/thermal (PV/T) Solar System%光伏/热(PV/T)太阳能系统的研究现状及解决方案

    Institute of Scientific and Technical Information of China (English)

    何永泰; 肖丽仙; 刘晋豪; 李雷

    2014-01-01

    The research status of the photovoltaic/thermal ( PV/T) solar system is introduced in the paper. The cause of poor practicability for the PV/T solar system is analyzed. In order to improver the practicability of the PV/T solar system, the solutions ( integrated condenser in PV/T solar system, opti-mized the structure of PV/T collector, balance of the conversion efficiency and the operation temperature, perfection evaluation method) are proposed based on the structure and theory of the PV/T collector.%本文介绍了PV/T太阳能系统的研究现状,分析了导致PV/T太阳能系统实用性差的原因。根据PV/T太阳能系统的结构特点及其相关理论,提出聚光技术与PV/T太阳能系统集成、 PV/T集热器结构优化、 PV/T太阳能系统转换效率与工作温度之间的平衡及完善PV/T太阳能特性评价体系的解决方案。实验证明方案有利于提高PV/T太阳能系统的实用性。

  16. Field analysis of solar PV-based collective systems for rural electrification.

    OpenAIRE

    Díaz, P.; Peña, R.; Muñoz Cano, Javier; Arias, C. A.; Sandoval, D

    2011-01-01

    This article analyses the long-term performance of collective off-grid photovoltaic (PV) systems in rural areas. The use of collective PV systems for the electrification of small medium-size villages in developing countries has increased in the recent years. They are basically set up as stand-alone installations (diesel hybrid or pure PV) with no connection with other electrical grids. Their particular conditions (isolated) and usual installation places (far from commercial/industrial centers...

  17. Optimal Capacity Allocation of Large-Scale Wind-PV-Battery Units

    OpenAIRE

    Kehe Wu; Huan Zhou; Jizhen Liu

    2014-01-01

    An optimal capacity allocation of large-scale wind-photovoltaic- (PV-) battery units was proposed. First, an output power model was established according to meteorological conditions. Then, a wind-PV-battery unit was connected to the power grid as a power-generation unit with a rated capacity under a fixed coordinated operation strategy. Second, the utilization rate of renewable energy sources and maximum wind-PV complementation was considered and the objective function of full life cycle-net...

  18. Final Technical Report: Advanced Measurement and Analysis of PV Derate Factors.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burton, Patrick D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hansen, Clifford [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The Advanced Measurement and Analysis of PV Derate Factors project focuses on improving the accuracy and reducing the uncertainty of PV performance model predictions by addressing a common element of all PV performance models referred to as “derates”. Widespread use of “rules of thumb”, combined with significant uncertainty regarding appropriate values for these factors contribute to uncertainty in projected energy production.

  19. Regulatory islanding parameters in battery based solar PV for electricity system resiliency

    OpenAIRE

    Alsayyed, Nidal; Zhu, Weihang

    2016-01-01

    Distributed battery based solar power photovoltaic (PV) systems have the potential to supply electricity during grid outages resulting from extreme weather or other emergency situations. As such, distributed PV can significantly increase the resiliency of the electricity system. In order to take advantage of this capability, however, the PV systems must be designed with regulatory parameters in mind and combined with other technologies, such as smart energy storage and auxiliary generation. S...

  20. Incremental Conductance MPPT Algorithm for PV System Implemented Using DC-DC Buck and Boost Converter

    OpenAIRE

    2014-01-01

    The two basic topologies of switch mode DC-DC converters (Buck and Boost) are analyzed with a view of their use in PV (photovoltaic) systems, as the photovoltaic generator exhibits non-linear characteristics due to the change in environmental condition and load variation. As the efficiency of PV panels is low it becomes mandatory to extract maximum power from the PV panel at a given period of time. Several MPPT algorithms with different types of converters are being proposed f...

  1. Grid Integration of PV Power based on PHIL testing using different Interface Algorithms

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso;

    2013-01-01

    Photovoltaic (PV) power among all renewable energies had the most accelerated growth rate in terms of installed capacity in recent years. Transmission System Operators (TSOs) changed their perspective about PV power and started to include it into their planning and operation, imposing PV systems...... and supply of ancillary services, first the grid has to be simulated using PHIL, but in order to achieve it, different interface algorithms (IA) had to be evaluated in terms of system stability and signal accuracy....

  2. Distributed Solar PV for Electricity System Resiliency: Policy and Regulatory Considerations (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    Distributed Solar PV systems have the potential of increasing the grid's resiliency to unforeseen events, such as extreme weather events and attacks. This paper presents the role that distributed PV can play in electric grid resiliency, introduces basic system design requirements and options, and discusses the regulatory and policy options for supporting the use of distributed PV for the purpose of increased electricity resiliency.

  3. Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2010-01-01

    PVs. In order to increase PV penetration level further, new voltage support control functions for individual inverters are required. This paper investigates distributed reactive power regulation and active power curtailment strategies regarding the development of PV connection capacity by evaluation......Admissible range of grid voltage is one of the strictest constraints for the penetration of distributed photovoltaic (PV) generators especially connection to low voltage (LV) public networks. Voltage limits are usually fulfilled either by network reinforcements or limiting of power injections from...

  4. Life cycle assessment study of solar PV systems: An example of a 2.7kW{sub p} distributed solar PV system in Singapore

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, R.; Leong, K.C.; Osman, R.; Ho, H.K. [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Tso, C.P. [Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450 Melaka (Malaysia)

    2006-05-15

    In life cycle assessment (LCA) of solar PV systems, energy pay back time (EPBT) is the commonly used indicator to justify its primary energy use. However, EPBT is a function of competing energy sources with which electricity from solar PV is compared, and amount of electricity generated from the solar PV system which varies with local irradiation and ambient conditions. Therefore, it is more appropriate to use site-specific EPBT for major decision-making in power generation planning. LCA and life cycle cost analysis are performed for a distributed 2.7kW{sub p} grid-connected mono-crystalline solar PV system operating in Singapore. This paper presents various EPBT analyses of the solar PV system with reference to a fuel oil-fired steam turbine and their greenhouse gas (GHG) emissions and costs are also compared. The study reveals that GHG emission from electricity generation from the solar PV system is less than one-fourth that from an oil-fired steam turbine plant and one-half that from a gas-fired combined cycle plant. However, the cost of electricity is about five to seven times higher than that from the oil or gas fired power plant. The environmental uncertainties of the solar PV system are also critically reviewed and presented. (author)

  5. Calculation Method and Analysis for the Annual Power Generation of PV Façades in China

    Institute of Scientific and Technical Information of China (English)

    Shen Xu; ZhongMing Hu; Jian Kang; Wei Liao; Jing Huang

    2014-01-01

    The application of PV façades emerges greatly in recent years and however its calculation methods and analysis remains insufficient under the weather conditions of China. In such demand, this paper investigates PV façade in terms of PV electricity generation in different arrangements and weather conditions of four major cities in China. The calculation models for PV façade are developed and validated by comparing the results with the measured data from the field experiments. A parametric study is carried out to provide a reference for the optimal design of the PV façades. The results show that with various cities, building orientations, building forms, materials and arrangements of PV modules, there is a distinct difference in the electrical output energy of PV façades. Weather conditions play a very important role in terms of PV generation performance of PV façades.

  6. EFFECT OF REFLECTOR APPLICATION ON PV PANEL PERFORMANCE UNDER EGYPTIAN CONDITIONS

    OpenAIRE

    Mamdouh Abbas HELMY; E. M. KHALIFA; A. M. OKSHA; A. W. ELHADDAD

    2014-01-01

    The proposed approach in the present study is to employ a mirror augmented PV solar panel to track the sun and reflect rays on to the PV panel. Its performance was compared with same PV module without reflector under the same environmental conditions. The mirror augmented solar PV panel tracked sun from East to West along the daytime in Winter 2011 with tilt angle0.523 rad (30 deg) for panel and 0.122 rad (7deg) for mirror which are estimated by experiment. The average energy output values of...

  7. Comparative Analysis and Considerations for PV Interconnection Standards in the United States and China

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-01-01

    The main objectives of this report are to evaluate China's photovoltaic (PV) interconnection standards and the U.S. counterparts and to propose recommendations for future revisions to these standards. This report references the 2013 report Comparative Study of Standards for Grid-Connected PV System in China, the U.S. and European Countries, which compares U.S., European, and China's PV grid interconnection standards; reviews various metrics for the characterization of distribution network with PV; and suggests modifications to China's PV interconnection standards and requirements. The recommendations are accompanied by assessments of four high-penetration PV grid interconnection cases in the United States to illustrate solutions implemented to resolve issues encountered at different sites. PV penetration in China and in the United States has significantly increased during the past several years, presenting comparable challenges depending on the conditions of the grid at the point of interconnection; solutions are generally unique to each interconnected PV installation or PV plant.

  8. Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Roger R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Balfour, John R. [High Performance PV, Phoenix, AZ (United States)

    2015-01-01

    Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

  9. Estimation of Maximum Allowable PV Connection to LV Residential Power Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2011-01-01

    Maximum photovoltaic (PV) hosting capacity of low voltage (LV) power networks is mainly restricted by either thermal limits of network components or grid voltage quality resulted from high penetration of distributed PV systems. This maximum hosting capacity may be lower than the available solar...... potential of geographic area due to power network limitations even though all rooftops are fully occupied with PV modules. Therefore, it becomes more of an issue to know what exactly limits higher PV penetration level and which solutions should be engaged efficiently such as over sizing distribution...

  10. Delta Power Control Strategy for Multi-String Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    With a still increasing penetration level of grid-connected PV systems, more advanced active power control functionalities have been introduced in certain grid regulations. A delta power constraint, where a portion of the active power from the PV panels is reserved during operation, is required...... for the entire PV system is achieved. Simulations and experiments have been performed on a 3-kW single-phase grid-connected PV system. The results have confirmed the effectiveness of the delta power control strategy, where the power reserve according to the delta power constraint is achieved under several...

  11. Dynamic response evaluation of sensorless MPPT method for hybrid PV-DFIG wind turbine system

    Directory of Open Access Journals (Sweden)

    Danvu Nguyen

    2016-01-01

    Full Text Available This research proposes a sensorless Maximum Power Point Tracking (MPPT method for a hybrid Photovoltaic-Wind system, which consists of Photovoltaic (PV system and Doubly-Fed Induction Generator (DFIG Wind Turbine. In the hybrid system, the DC/DC converter output of the PV system is directly connected to the DC-link of DFIG’s back-to-back converter. Therefore, the PV inverter and its associated circuit can be removed in this structure. Typically, the PV power is monitored by using PV current sensor and PV voltage sensor for MPPT. In this paper, the powers of converters on grid side and rotor side of DFIG are used to estimate the PV power without the PV current sensor. That can efficiently reduce the cost of the hybrid system. The detailed analysis of the sensorless MPPT method, which includes derived equations and operation response, is also presented in this paper. In addition, an overview of PV-DFIG research in literature is stated to supply comprehensive knowledge of related research.

  12. Determining the Effects of Environment and Atmospheric Parameters on PV Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Micheli, Leonardo; Muller, Matthew; Kurtz, Sarah

    2016-11-21

    The performance losses due to soiling occurring on any photovoltaic (PV) device are caused by a complex mechanism that involves numerous factors and their interactions. For this reason, the present work analyzes the outputs of reference PV cells installed in various locations, with the aim of contributing to the identification of the most important factors influencing the accumulation of dust on a PV surface. Parameters such as the air-quality indexes, the recurrence and the amount of rainfall and the climate zone are investigated and related to the soiling losses of the PV device.

  13. Optimization of SiC-based H5 and Conergy-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The transformerless DC/AC inverters are critical components in the rapidly growing market of grid-connected Photovoltaic (PV) applications. Also, the SiC-based power semiconductors are capable to operate reliably at high operating temperature and switches frequency levels. In this paper, a new...... profitability of the PV system....... design technique is presented for optimizing the switching frequency and structure of the LCL-type output filter in transformerless H5 and Conergy-NPC PV inverters, which employ SiC-type power devices. The design optimization results demonstrate that the optimized SiC-based PV inverters are more...

  14. Modeling of PV Systems Based on Inflection Points Technique Considering Reverse Mode

    Directory of Open Access Journals (Sweden)

    Bonie J. Restrepo-Cuestas

    2013-11-01

    Full Text Available This paper proposes a methodology for photovoltaic (PV systems modeling, considering their behavior in both direct and reverse operating mode and considering mismatching conditions. The proposed methodology is based on the inflection points technique with a linear approximation to model the bypass diode and a simplified PV model. The proposed mathematical model allows to evaluate the energetic performance of a PV system, exhibiting short simulation times in large PV systems. In addition, this methodology allows to estimate the condition of the modules affected by the partial shading since it is possible to know the power dissipated due to its operation at the second quadrant.

  15. Intelligent control of PV system on the basis of the fuzzy recurrent neuronet*

    Science.gov (United States)

    Engel, E. A.; Kovalev, I. V.; Engel, N. E.

    2016-04-01

    This paper presents the fuzzy recurrent neuronet for PV system’s control. Based on the PV system’s state, the fuzzy recurrent neural net tracks the maximum power point under random perturbations. The validity and advantages of the proposed intelligent control of PV system are demonstrated by numerical simulations. The simulation results show that the proposed intelligent control of PV system achieves real-time control speed and competitive performance, as compared to a classical control scheme on the basis of the perturbation & observation algorithm.

  16. Distribution System Augmented by DC Links for Increasing the Hosting Capacity of PV Generation

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Demirok, Erhan; Teodorescu, Remus

    2012-01-01

    This paper presents a concept of enhancing the photovoltaic (PV) power generation hosting capacity of distribution networks. Distribution network serving electrical energy to farm settlements was selected as an example for their large roof area available for PV installation. Further, they are cha......This paper presents a concept of enhancing the photovoltaic (PV) power generation hosting capacity of distribution networks. Distribution network serving electrical energy to farm settlements was selected as an example for their large roof area available for PV installation. Further...

  17. Development and implementation of a PV performance monitoring system based on inverter measurements

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Gavriluta, Anamaria Florina; Sera, Dezso

    2016-01-01

    applications the cost of the performance monitoring hardware and implementation is still high. Therefore, we present the practical development and implementation of a low-cost PV performance monitoring system for residential and commercial PV applications, based on the inverter’s own monitoring......Performance monitoring and fault detection systems are becoming more common in large photovoltaic (PV) plants as they can contribute to decreasing operation and maintenance costs, as well as for maximizing plant yield and lifetime. However, in case of residential and smaller commercial PV system...

  18. Silicon shortage: supply constraints limit PV growth until 2008

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, H.; Bradford, T. [Prometheus Inst. (United States)

    2006-10-01

    It is argued that a shortage of refined (polycystalline) silicon will curtail the expansion of the solar photovoltaics industry until about 2008. At present, 94% of PV cells produced worldwide use refined silicon. The problem has arisen because the traditional source, scrap silicon from the electronics industry, is no longer available in sufficient quantities - demand has outstripped supply. Although plans are in place to double the present supply of silicon over the next four years, doubts are expressed over the likelihood of this happening. Currently, there are only seven big companies producing the silicon - production figures for these companies are given. (author)

  19. Spectrally-Selective Photonic Structures for PV Applications

    Directory of Open Access Journals (Sweden)

    Benedikt Bläsi

    2010-01-01

    Full Text Available We review several examples of how spectrally-selective photonic structures may be used to improve solar cell systems. Firstly, we introduce different spectrally-selective structures that are based on interference effects. Examples shown include Rugate filter, edge filter and 3D photonic crystals such as artificial opals. In the second part, we discuss several examples of photovoltaic (PV concepts that utilize spectral selectivity such as fluorescence collectors, upconversion systems, spectrum splitting concepts and the intermediate reflector concept. The potential of spectrally selective filters in the context of solar cells is discussed.

  20. Weather modeling and forecasting of PV systems operation

    CERN Document Server

    Paulescu, Marius; Gravila, Paul; Badescu, Viorel

    2012-01-01

    In the past decade, there has been a substantial increase of grid-feeding photovoltaic applications, thus raising the importance of solar electricity in the energy mix. This trend is expected to continue and may even increase. Apart from the high initial investment cost, the fluctuating nature of the solar resource raises particular insertion problems in electrical networks. Proper grid managing demands short- and long-time forecasting of solar power plant output. Weather modeling and forecasting of PV systems operation is focused on this issue. Models for predicting the state of the sky, nowc

  1. Power Electronic System for Multi-MW PV sites

    DEFF Research Database (Denmark)

    Paasch, Kasper

    for solar inverters is under a severe pressure regarding cost reduction. The main topic of this thesis is the investigation of the potential advantage of applying string inverters with multiple Maximum-Power-Point-trackers (MPPT) in large PV plants compared to the use of one large central inverter with one.......4%. A portable IV-scanning instrument for the fast long term characterization of solar panels was developed as part of the project. Each second a sweep of the IV-characteristics of a solar panel is performed and the result stored for later analysis. The instrument is based on an active load, is optimized...

  2. Analysis of Irradiance Models for Bifacial PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Clifford W.; Stein, Joshua S.; Deline, Chris; MacAlpine, Sara; Marion, Bill; Asgharzadeh, Amir; Toor, Fatima

    2016-11-21

    We describe and compare two methods for modeling irradiance on the back surface of rack-mounted bifacial PV modules: view factor models and ray-tracing simulations. For each method we formulate one or more models and compare each model with irradiance measurements and short circuit current for a bifacial module mounted a fixed tilt rack with three other similarly sized modules. Our analysis illustrates the computational requirements of the different methods and provides insight into their practical applications. We find a level of consistency among the models which indicates that consistent models may be obtained by parameter calibrations.

  3. Genomic and evolutionary features of the SPI-1 type III secretion system that is present in Xanthomonas albilineans but is not essential for xylem colonization and symptom development of sugarcane leaf scald.

    Science.gov (United States)

    Marguerettaz, Mélanie; Pieretti, Isabelle; Gayral, Philippe; Puig, Jérôme; Brin, Chrystelle; Cociancich, Stéphane; Poussier, Stéphane; Rott, Philippe; Royer, Monique

    2011-02-01

    Xanthomonas albilineans is the causal agent of sugarcane leaf scald. Interestingly, this bacterium, which is not known to be insect or animal associated, possesses a type III secretion system (T3SS) belonging to the injectisome family Salmonella pathogenicity island 1 (SPI-1). The T3SS SPI-1 of X. albilineans shares only low similarity with other available T3SS SPI-1 sequences. Screening of a collection of 128 plant-pathogenic bacteria revealed that this T3SS SPI-1 is present in only two species of Xanthomonas: X. albilineans and X. axonopodis pv. phaseoli. Inoculation of sugarcane with knockout mutants showed that this system is not required by X. albilineans to spread within xylem vessels and to cause disease symptoms. This result was confirmed by the absence of this T3SS SPI-1 in an X. albilineans strain isolated from diseased sugarcane. To investigate the importance of the T3SS SPI-1 during the life cycle of X. albilineans, we analyzed T3SS SPI-1 sequences from 11 strains spanning the genetic diversity of this species. No nonsense mutations or frameshifting indels were observed in any of these strains, suggesting that the T3SS SPI-1 system is maintained within the species X. albilineans. Evolutionary features of T3SS SPI-1 based on phylogenetic, recombination, and selection analyses are discussed in the context of the possible functional importance of T3SS SPI-1 in the ecology of X. albilineans.

  4. Sizing and Simulation of PV-Wind Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2013-01-01

    Full Text Available A sizing procedure is developed for hybrid system with the aid of mathematical models for photovoltaic cell, wind turbine, and battery that are readily present in the literature. This sizing procedure can simulate the annual performance of different kinds of photovoltaic-wind hybrid power system structures for an identified set of renewable resources, which fulfills technical limitations with the lowest energy cost. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Security lightning application is selected, whereas system performance data and environmental operating conditions are measured and stored. This hybrid system, which includes a PV, wind turbine, inverter, and a battery, was installed to supply energy to 24 W lamps, considering that the renewable energy resources of this site where the system was installed were 1700 Wh/m2/day solar radiation and 3.43 m/s yearly average wind speed. Using the measured variables, the inverter and charge regulator efficiencies were calculated as 90% and 98%, respectively, and the overall system’s electrical efficiency is calculated as 72%. Life cycle costs per kWh are found to be $0.89 and LLP = 0.0428.

  5. Centre for Interactive Research on Sustainability : integration of PV

    Energy Technology Data Exchange (ETDEWEB)

    Cole, R.J. [British Columbia Univ., Vancouver, BC (Canada). School of Architecture and Landscape Architecture; Cayuela, A.; McCarry, B. [Stantec Consulting Ltd., Surrey, BC (Canada); Robinson, J. [British Columbia Univ., Vancouver, BC (Canada); Tabatabaian, M.; Yen, D. [British Columbia Institute of Technology, Burnaby, BC (Canada)

    2007-07-01

    This paper provided details of the building-integrated photovoltaic (BIPV) system designed for the Centre for Interactive Research on Sustainability (CIRS). The centre will be used as a research vehicle for the assessment and monitoring of sustainable building products and practices. The BIPV will occupy an area of 170 m{sup 2}, and will encompass the south-facing modules of an atrium skylight saw-tooth. Installed capacity of the system will be 23 kWp. The tilt angle of the south-facing part of the skylight will be 30 degrees. Real time monitoring and display of the energy provided by the BIPV is expected to provide feedback for the researchers and allow the public to gain a better understanding of its operation. The BIPV was designed to be a net producer of energy for the centre and is one of several clean energy strategies that will be used to ensure that the centre remains carbon neutral. The design of the PV system and its overall transparently will ensure that the centre uses 100 per cent daylighting. Rainwater will also be collected on the PV surfaces. The BIPV will be monitored as part of a research program developing anticipatory-predictive control algorithms for solar-optimized buildings, and was designed to be accessible to the public. It was concluded that the BIPV system will lead to greater public and industry acceptance of solar technology. 7 refs., 2 tabs., 7 figs.

  6. A control strategy for PV stand-alone applications

    Science.gov (United States)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  7. Curtobacterium flaccumfaciens pv. flaccumfaciens: etiology, detection and control strategies

    Directory of Open Access Journals (Sweden)

    Giseli Valentini

    2010-12-01

    Full Text Available The diseases caused by bacteria present a phytopathological and agricultural problem in various economic crops. The Curtobacterium wilt caused by Curtobacterium fl accumfaciens pv. fl accumfaciens has become a threat to the cultivation of beans (Phaseolus vulgaris L.. The disease statement for the Brazilian territory occurred in 1995 and today the pathogen is distributed in various Brazilian producing regions. Transmission is primarily via contaminated seed, which imposes great diffi culties and limitations on the control of these bacteria. After plant infection, the only way to control it is the eradication of infected plants. The alternatives for the control of this disease are the use of healthy seeds, crop rotation and resistant varieties. The use of resistant varieties is the most effi cient and economical solution for the farmer. The most important research to support the development of bean cultivars resistant to C. fl accumfaciens pv. fl accumfaciens is the identifi cation of sources of genetic resistance and the study of mechanisms of genetic resistance to disease.

  8. Trimode Power Converter optimizes PV, diesel and battery energy sources

    Science.gov (United States)

    Osullivan, George; Bonn, Russell; Bower, Ward

    1994-12-01

    Conservatively, there are 100,000 localities in the world waiting for the benefits that electricity can provide, and many of these are in climates where sunshine is plentiful. With these locations in mind a prototype 30 kW hybrid system has been assembled at Sandia to prove the reliability and economics of photovoltaic, diesel and battery energy sources managed by an autonomous power converter. In the Trimode Power Converter the same power parts, four IGBT's with an isolation transformer and filter components, serve as rectifier and charger to charge the battery from the diesel; as a stand-alone inverter to convert PV and battery energy to AC; and, as a parallel inverter with the diesel-generator to accommodate loads larger than the rating of the diesel. Whenever the diesel is supplying the load, an algorithm assures that the diesel is running at maximum efficiency by regulating the battery charger operating point. Given the profile of anticipated solar energy, the cost of transporting diesel fuel to a remote location and a five year projection of load demand, a method to size the PV array, battery and diesel for least cost is developed.

  9. Assuring long-term reliability of concentrator PV systems

    Science.gov (United States)

    McConnell, R.; Garboushian, V.; Brown, J.; Crawford, C.; Darban, K.; Dutra, D.; Geer, S.; Ghassemian, V.; Gordon, R.; Kinsey, G.; Stone, K.; Turner, G.

    2009-08-01

    Concentrator PV (CPV) systems have attracted significant interest because these systems incorporate the world's highest efficiency solar cells and they are targeting the lowest cost production of solar electricity for the world's utility markets. Because these systems are just entering solar markets, manufacturers and customers need to assure their reliability for many years of operation. There are three general approaches for assuring CPV reliability: 1) field testing and development over many years leading to improved product designs, 2) testing to internationally accepted qualification standards (especially for new products) and 3) extended reliability tests to identify critical weaknesses in a new component or design. Amonix has been a pioneer in all three of these approaches. Amonix has an internal library of field failure data spanning over 15 years that serves as the basis for its seven generations of CPV systems. An Amonix product served as the test CPV module for the development of the world's first qualification standard completed in March 2001. Amonix staff has served on international standards development committees, such as the International Electrotechnical Commission (IEC), in support of developing CPV standards needed in today's rapidly expanding solar markets. Recently Amonix employed extended reliability test procedures to assure reliability of multijunction solar cell operation in its seventh generation high concentration PV system. This paper will discuss how these three approaches have all contributed to assuring reliability of the Amonix systems.

  10. Islanding Issues of Grid-connected PV Systems

    Directory of Open Access Journals (Sweden)

    S.Narendiran

    2013-04-01

    Full Text Available ‘Islanding’ is a term, which refers to the situation when the Distributed generator (DG continues to power the consumer-end even when the electrical power from the electric utility is no longerpresent. Islanding phenomenon occurs after the certain part of the utility grid gets disconnected from a large number of inter-connected PVs. It leads to troubles in voltage and frequency control and powerquality issues. Therefore there is a need for appropriate anti-islanding measures for grid-connected PV systems. There are two ways to defeat the islanding phenomenon, by reactor insertion method on utility side and capacitor insertion method on PV side. Some of the Islanding detection methods (IDMs are broadly classifies as Active, Passive and Utility based. Active mode of detection includes impedance measurement, slip mode frequency shift and frequency bias. Passive methods contain over/under voltage and frequency and harmonics detection. Utility-based methods consist of manual disconnection, SCADA, impedance insertion.

  11. Temperature Dependences on Various Types of Photovoltaic (PV) Panel

    Science.gov (United States)

    Audwinto, I. A.; Leong, C. S.; Sopian, K.; Zaidi, S. H.

    2015-09-01

    Temperature is one of the key roles in PV technology performance, since with the increases of temperature the open-circuit voltage will drop accordingly so do the electrical efficiency and power output generation. Different types of Photovoltaic (PV) panels- silicon solar panels and thin film solar panels; mono-crystalline, poly-crystalline, CIS, CIGS, CdTe, back-contact, and bi-facial solar panel under 40°C to 70°C approximately with 5°C interval have been comparatively analyzed their actual performances with uniformly distribution of light illumination from tungsten halogen light source, ±500W/m2. DC-Electronic Load and Data Logger devices with “Lab View” data program interface were used to collect all the necessary parameters in this study. Time needed to achieve a certain degree of temperature was recorded. Generally, each of the panels needed 15 minutes to 20 minutes to reach 70°C. Halogen based light source is not compatible in short wave-length in response to thin-film solar cell. Within this period of times, all the panels are facing a performance loss up to 15%. Other parameters; Pmax, Vmax, Imax, Voc, Isc, Rserries, Rshunt, Fillfactor were collected as study cases. Our study is important in determining Photovoltaic type selection and system design as for study or industrial needed under different temperature condition.

  12. Future of Grid-Tied PV Business Models: What Will Happen When PV Penetration on the Distribution Grid is Significant? Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Graham, S.; Katofsky, R.; Frantzis, L.; Sawyer, H.; Margolis, R.

    2008-05-01

    Eventually, distributed PV will become a more significant part of the generation mix. When this happens, it is expected that utilities will have to take on a more active role in the placement, operation and control of these systems. There are operational complexities and concerns of revenue erosion that will drive utilities into greater involvement of distributed PV and will create new business models. This report summarizes work done by Navigant Consulting Inc. for the National Renewable Energy Laboratory as part of the Department of Energy's work on Renewable System Integration. The objective of the work was to better understand the structure of these future business models and the research, development and demonstration (RD&D) required to support their deployment. This report describes potential future PV business models in terms of combinations of utility ownership and control of the PV assets, and the various relationships between end-users and third-party owners.

  13. Induction of Callose Deposition in Tobacco (Nicotiana tabacum by Bacterial Lipopolysaccharide Pseudomonas syringae pv. tabaci and Pseudomonas syringae pv. glycinea

    Directory of Open Access Journals (Sweden)

    Pipit Marianingsih

    2014-12-01

    Full Text Available Lipopolysaccharide (LPS is a major component of outer-membrane gram-negative bacteria, and it can act as a Pathogen-Associated Molecular Pattern (PAMP for perception of pathogens by plants. LPS can be recognized by plants, triggering certain plant defense-related responses, including callose deposition. This study investigated induction of callose deposition by bacterial LPS in tobacco. Tobacco leaves were infiltrated with 400 μg/mL and 800 μg/mL LPS extracted from Pseudomonas syringae pv. tabaci (Pta and Pseudomonas syringae pv. glycinea (Pgl and incubated for 24 h or 48 h. To detect callose deposition, tobacco leaves were cleared in lactophenol solution, stained with aniline blue, and visualized by fluorescence microscopy. Results showed that LPS from Pgl induced more callose deposition in tobacco leaves than did that from Pta. In addition, a Pearson correlation test revealed that incubation period was the most significant factor in callose deposition, followed by the type of LPS bacteria. However, LPS concentration was not significantly corelated to callose deposition in tobacco leaves.

  14. Lithium Ion Batteries Ageing Analysis when used in a PV Power Plants

    DEFF Research Database (Denmark)

    Beltran, H.; Swierczynski, Maciej Jozef; Aparicio, N.;

    2012-01-01

    This paper analyzes the integration of lithium ion (Li-ion) batteries into large scale grid-connected PV plants. It performs a systematic analysis on both the operation improvement obtained by a PV+ES power plant and the ageing experienced by the Li-ion batteries used as Energy Storage (ES) system...

  15. Seroepidemiology of TmPV1 infection in captive and wild Florida manatees (Trichechus manatus latirostris)

    Science.gov (United States)

    Dona, Maria Gabriella; Rehtanz, Manuela; Adimey, Nicole M.; Bossart, Gregory D.; Jenson, Alfred B.; Bonde, Robert K.; Ghim, Shin-je

    2011-01-01

    In 1997, cutaneous papillomatosis caused by Florida manatee (Trichechus manatus latirostris [Tm]) papillomavirus 1 (TmPV1) was detected in seven captive manatees at the Homosassa Springs Wildlife State Park, Florida, USA, and, subsequently, in two wild manatees from the adjacent Homosassa River. Since then, papillomatosis has been reported in captive manatees housed in other locations, but not in wild animals. To determine TmPV1 antibody prevalence in captive and wild manatees sampled at various locations throughout Florida coastal regions, virus-like particles, composed of the L1 capsid protein of TmPV1, were generated with a baculovirus expression system and used to measure anti-TmPV1 antibodies in an enzyme-linked immunosorbent assay. Serologic analysis of 156 manatees revealed a TmPV1 antibody prevalence of 26.3%, with no significant difference between captive (n=39) and wild (n=117) manatees (28.2% and 25.6%, respectively). No antibody-positive wild animal showed PV-induced cutaneous lesions, whereas papillomatosis was observed in 72.7% of antibody-positive captive manatees. Our data indicate that Florida manatees living in the wild are naturally infected by TmPV1 but rarely show TmPV1-induced papillomatosis. Hence, it appears that the wild population would not be harmed in a case of contact with captive animals without visible lesions and productive infections, which could be thus released into the wild.

  16. Moving to a Higher Level for PV Reliability through Comprehensive Standards Based on Solid Science (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.

    2014-11-01

    PV reliability is a challenging topic because of the desired long life of PV modules, the diversity of use environments and the pressure on companies to rapidly reduce their costs. This presentation describes the challenges, examples of failure mechanisms that we know or don't know how to test for, and how a scientific approach is being used to establish international standards.

  17. Indoor simulation and testing of photovoltaic thermal (PV/T) air collectors

    NARCIS (Netherlands)

    Solanki, S.C.; Dubey, Swapnil; Tiwari, Arvind

    2009-01-01

    An indoor standard test procedure has been developed for thermal and electrical testing of PV/T collectors connected in series. For this, a PV/T solar air heater has been designed, fabricated and its performance over different operating parameters were studied. Based on the energy balance equations,

  18. Distributed measurement system for long term monitoring of clouding effects on large PV plants

    DEFF Research Database (Denmark)

    Paasch, K. M.; Nymand, M.; Haase, F.

    2013-01-01

    A recording system for the generation of current-voltage characteristics of solar panels is presented. The system is intended for large area PV power plants. The recorded curves are used to optimize the energy output of PV power plants, which are likely to be influenced by passing clouds...

  19. Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; He, Ran; Jian, Jiamin;

    2016-01-01

    Eliminating the leakage current is one of the most important issues for transformerless three phase photovoltaic (PV) systems. In this paper, the leakage current elimination of a three-phase four-leg PV inverter is investigated. With the common mode loop model established, the generation mechanism...

  20. Solution to avoid unwanted trips for PV systems connected to LV network facing voltage sags

    Energy Technology Data Exchange (ETDEWEB)

    Le Thi Minh, Chau; Tran-Quoc, Tuan; Kieny, Christophe [IDEA, Saint-Martin-d' Heres (France); Bacha, Seddik [Grenoble Electric Engineering Laboratory, Saint-Martin-d' Heres (France); Cabanac, Philippe; Grenard, Sebastien [Electricite de France, Clamart (France). Direction des Etudes et Recherches; Goulielmakis, David [Schneider Electric, Grenoble (France). Projects and Engineering Center

    2011-07-01

    Most of photovoltaic (PV) systems connected to low voltage (LV) distribution networks have a single-phase connection. The analysis of the behavior of these single-phase connection. The analysis of the behavior of these single-phase PV inverters facing voltage sags caused by short circuits is of major concern. These behaviors depend on fault types, fault location, types of grid architecture, grid protection systems (with or without auto-recloser system) and PV protection types. Therefore, the first investigation of this work is to study comprehensively the behaviors of PV systems connected to real LV networks facing voltage sags in different scenarios by taking into account the real network protection. Furthermore, future power systems with a large share of PV systems connected could be severely affected if several of the PV systems are tripping at the same instant. From these results of simulation, unwanted trip cases, due to the disconnection protection of PV systems are identified. Finally, a simple efficient solution by using the voltage-time characteristic for PV system is proposed. The validation by simulations shows the efficiency of the proposed solution. (orig.)

  1. Seroepidemiology of TmPV1 infection in captive and wild Florida manatees (Trichechus manatus latirostris).

    Science.gov (United States)

    Donà, Maria Gabriella; Rehtanz, Manuela; Adimey, Nicole M; Bossart, Gregory D; Jenson, Alfred B; Bonde, Robert K; Ghim, Shin-je

    2011-07-01

    In 1997, cutaneous papillomatosis caused by Florida manatee (Trichechus manatus latirostris [Tm]) papillomavirus 1 (TmPV1) was detected in seven captive manatees at the Homosassa Springs Wildlife State Park, Florida, USA, and, subsequently, in two wild manatees from the adjacent Homosassa River. Since then, papillomatosis has been reported in captive manatees housed in other locations, but not in wild animals. To determine TmPV1 antibody prevalence in captive and wild manatees sampled at various locations throughout Florida coastal regions, virus-like particles, composed of the L1 capsid protein of TmPV1, were generated with a baculovirus expression system and used to measure anti-TmPV1 antibodies in an enzyme-linked immunosorbent assay. Serologic analysis of 156 manatees revealed a TmPV1 antibody prevalence of 26.3%, with no significant difference between captive (n=39) and wild (n=117) manatees (28.2% and 25.6%, respectively). No antibody-positive wild animal showed PV-induced cutaneous lesions, whereas papillomatosis was observed in 72.7% of antibody-positive captive manatees. Our data indicate that Florida manatees living in the wild are naturally infected by TmPV1 but rarely show TmPV1-induced papillomatosis. Hence, it appears that the wild population would not be harmed in a case of contact with captive animals without visible lesions and productive infections, which could be thus released into the wild.

  2. Solar Eclipse: The rise and "dusk" of the Dutch PV Innovation System

    NARCIS (Netherlands)

    Negro, S.O.; Vasseur, V.; Sark, W.G.J.H.M. van; Hekkert, M.P.

    2012-01-01

    In this paper, we take the theoretical perspective of innovation system dynamics and apply this to Photovoltaic (PV) solar energy technology in the Netherlands. The history of the development of the PV innovation system is analysed in terms of seven key processes that are essential for the build-up

  3. CO2 Emissions of PV in the Perspective of a Renewable Energy Economy

    NARCIS (Netherlands)

    van Sark, W.G.J.H.M.; Reich, N.H.; Alsema, E.A.; Nieuwlaar, E.

    2007-01-01

    The wide range of greenhouse gas emissions (30-300 g CO2-eq/kWh) quoted for PV generated electricity in life cycle assessment studies so far is shown to be mainly caused by the different CO2 emission of energy consumed in manufacture of PV modules. A better way of comparing the CO2-eq emissions woul

  4. A fault diagnosis system for PV power station based on global partitioned gradually approximation method

    Science.gov (United States)

    Wang, S.; Zhang, X. N.; Gao, D. D.; Liu, H. X.; Ye, J.; Li, L. R.

    2016-08-01

    As the solar photovoltaic (PV) power is applied extensively, more attentions are paid to the maintenance and fault diagnosis of PV power plants. Based on analysis of the structure of PV power station, the global partitioned gradually approximation method is proposed as a fault diagnosis algorithm to determine and locate the fault of PV panels. The PV array is divided into 16x16 blocks and numbered. On the basis of modularly processing of the PV array, the current values of each block are analyzed. The mean current value of each block is used for calculating the fault weigh factor. The fault threshold is defined to determine the fault, and the shade is considered to reduce the probability of misjudgments. A fault diagnosis system is designed and implemented with LabVIEW. And it has some functions including the data realtime display, online check, statistics, real-time prediction and fault diagnosis. Through the data from PV plants, the algorithm is verified. The results show that the fault diagnosis results are accurate, and the system works well. The validity and the possibility of the system are verified by the results as well. The developed system will be benefit for the maintenance and management of large scale PV array.

  5. The wind chill temperature effect on a large-scale PV plant—an exergy approach

    DEFF Research Database (Denmark)

    Xydis, George

    2013-01-01

    (PV) system. Atmospheric variables such as air temperature, humidity and wind speed and their effects, shadow effects, tracking losses, and low radiation losses of the PV power output were investigated aiming at identifying the real and net solar energy output. It was shown that some usually...

  6. Effective information channels for reducing costs of environmentally- friendly technologies: evidence from residential PV markets

    Science.gov (United States)

    Rai, Varun; Robinson, Scott A.

    2013-03-01

    Realizing the environmental benefits of solar photovoltaics (PV) will require reducing costs associated with perception, informational gaps and technological uncertainties. To identify opportunities to decrease costs associated with residential PV adoption, in this letter we use multivariate regression models to analyze a unique, household-level dataset of PV adopters in Texas (USA) to systematically quantify the effect of different information channels on aspiring PV adopters’ decision-making. We find that the length of the decision period depends on the business model, such as whether the system was bought or leased, and on special opportunities to learn, such as the influence of other PV owners in the neighborhood. This influence accrues passively through merely witnessing PV systems in the neighborhood, increasing confidence and motivation, as well as actively through peer-to-peer communications. Using these insights we propose a new framework to provide public information on PV that could drastically reduce barriers to PV adoption, thereby accelerating its market penetration and environmental benefits. This framework could also serve as a model for other distributed generation technologies.

  7. How China became a leader in solar PV : An innovation system analysis

    NARCIS (Netherlands)

    Huang, Ping; Negro, Simona O.; Hekkert, Marko P.; Bi, Kexin

    2016-01-01

    In this paper we focus on understanding the rapid rise of the Chinese PV industry and its profound impact on the global PV industry. We investigate how it is possible that a nation that is still focusing on catching up in terms of industry, innovation and technology has been able to bring manufactur

  8. Design and Operation Studies of A Stand-Alone PV Generation System

    DEFF Research Database (Denmark)

    Hu, Yanting; Chen, Zhe; Zhang, Donglai

    2013-01-01

    This paper discusses the modeling, design and operation of a PV powered stand-alone system, which includes a PV array, a battery bank, power electronic converters and the associated control system. The design considerations are analyzed and a design platform is presented. Furthermore the operatio...

  9. Stabilization of hexa-coordinated P(v) corroles by axial silyloxy groups.

    Science.gov (United States)

    Chatterjee, Tamal; Lee, Way-Zen; Ravikanth, Mangalampalli

    2016-05-04

    We report the stabilization of the hexa-coordination environment for P(v) corroles by using alkyl/aryl substituted silyloxy groups as axial ligands. The P(v) corroles are highly fluorescent in a hexa-coordination environment compared to in a penta-coordination environment. However, P(v) corroles generally undergo axial ligand dissociation to form a mixture of penta- and hexa-coordinated P(v) corroles in non-coordinating solvents such as toluene, CH2Cl2, CHCl3. The usage of moderately bulkier and electron-donating silyloxy groups helps to restrict the axial ligand dissociation of silyloxy substituted hexa-coordinated P(v) corroles in non-coordinating solvents. The crystal structure confirmed the hexa-coordination geometry for the P(v) corroles. The P(v) corroles strongly absorb and emit in the visible region, with decent quantum yields and singlet state lifetimes. The hexa-coordinated P(v) corroles are highly stable under electrochemical conditions.

  10. Market dynamics, innovation, and transition in China's solar photovoltaic (PV) industry

    DEFF Research Database (Denmark)

    Zou, Hongyang; Du, Huibin; Ren, Jingzheng

    2017-01-01

    China’s photovoltaic (PV) industry has undergone dramatic development in recent years and is now the global market leader in terms of newly added capacity. However, market diffusion and adoption in China is not ideal. This paper examines the blocking and inducement mechanisms of China’s PV industry...

  11. Market dynamics, innovation, and transition in China's solar photovoltaic (PV) industry: A critical review

    DEFF Research Database (Denmark)

    Zou, Hongyang; Du, Huibin; Ren, Jingzheng

    2016-01-01

    China’s photovoltaic (PV) industry has undergone dramatic development in recent years and is now the global market leader in terms of newly added capacity. However, market diffusion and adoption in China is not ideal. This paper examines the blocking and inducement mechanisms of China’s PV industry...

  12. Energy and exergy analysis of PV/T air collectors connected in series

    NARCIS (Netherlands)

    Dubey, Swapnil; Solanki, S.C.; Tiwari, Arvind

    2009-01-01

    In this paper an attempt has been made to derive the analytical expressions for N hybrid photovoltaic/thermal (PV/T) air collectors connected in series. The performance of collectors is evaluated by considering the two different cases, namely, Case I (air collector is fully covered by PV module (gla

  13. PV-wind hybrid system performance. A new approach and a case study

    Energy Technology Data Exchange (ETDEWEB)

    Arribas, Luis; Cano, Luis; Cruz, Ignacio [Departamento de Energias Renovables, CIEMAT, Avda. Complutense 22, 28040 Madrid (Spain); Mata, Montserrat; Llobet, Ermen [Ecotecnia, Roc Boronat 78, 08005 Barcelona (Spain)

    2010-01-15

    Until now, there is no internationally accepted guideline for the measurement, data exchange and analysis of PV-Wind Hybrid Systems. As there is a need for such a tool, so as to overcome the barrier that the lack of confidence due to the absence of reliability means for the development of the market of Hybrid Systems, an effort has been made to suggest one tool for PV-Wind Hybrid Systems. The suggested guidelines presented in this work are based on the existing guidelines for PV Systems, as a PV-Wind Hybrid system can be roughly thought of as a PV System to which wind generation has been added. So, the guidelines for PV Systems are valid for the PV-Wind System, and only the part referred to wind generation should be included. This has been the process followed in this work. The proposed method is applied to a case study, the CICLOPS Project, a 5 kW PV, 7.5 kW Wind Hybrid system installed at the Isolated Wind Systems Test Site that CIEMAT owns in CEDER (Soria, Spain). This system has been fully monitored through a year and the results of the monitoring activity, characterizing the long-term performance of the system are shown in this work. (author)

  14. Efficiency of procedures for induction and cultivation of Pseudomonas syringae pv. pisi L-form

    NARCIS (Netherlands)

    Elvira-Recuenco, M.; Vuurde, van J.W.L.

    2003-01-01

    The L-form of Pseudomonas syringae pv. phaseolicola has been proved to induce resistance to bean halo blight.Various procedures were tested to induce the L-form of Pseudomonas syringae pv. pisi for its potential use as biocontrol agent of pea bacterial blight. Cell-wall deficient cells were induced

  15. Stability of Grid-Connected PV Inverters with Large Grid Impedance Variation

    DEFF Research Database (Denmark)

    Liserre, Marco; Teodorescu, Remus; Blaabjerg, Frede

    2004-01-01

    Photovoltaic (PV) inverters used in dispersed power generation of houses in the range of 1-5 kW are currently available from several manufactures. However, large grid impedance variation is challenging the control and the grid filter design in terms of stability. In fact the PV systems are well...

  16. Design, production and materials of PV-powered consumer products - The case of mass production

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Akkerman, R.

    2005-01-01

    Though many options exist, the application of integrated PV systems in mass produced consumer products is still unusual and rare [1]. Therefore, to date, design and manufacturing aspects of product-integrated PV systems have been explored only to a very limited extent. The requirements for the desig

  17. Solar PV O&M Standards and Best Practices - Existing Gaps and Improvement Efforts

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Balfour, John R. [High Performance PV, Phoenix, AZ (United States); Keating, T. J. [SunSpec Alliance, San Jose, CA (United States)

    2014-11-01

    As greater numbers of photovoltaic (PV) systems are being installed, operations & maintenance (O&M) activities will need to be performed to ensure the PV system is operating as designed over its useful lifetime. To mitigate risks to PV system availability and performance, standardized procedures for O&M activities are needed to ensure high reliability and long-term system bankability. Efforts are just getting underway to address the need for standard O&M procedures as PV gains a larger share of U.S. generation capacity. Due to the existing landscape of how and where PV is installed, including distributed generation from small and medium PV systems, as well as large, centralized utility-scale PV, O&M activities will require different levels of expertise and reporting, making standards even more important. This report summarizes recent efforts made by solar industry stakeholders to identify the existing standards and best practices applied to solar PV O&M activities, and determine the gaps that have yet to be, or are currently being addressed by industry.

  18. Solar PV O&M Standards and Best Practices – Existing Gaps and Improvement Efforts

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Balfour, John R. [High Performance PV, Phoenix, AZ (United States); Keating, T. J. [SunSpec Alliance, San Jose, CA (United States)

    2014-11-01

    As greater numbers of photovoltaic (PV) systems are being installed, operations & maintenance (O&M) activities will need to be performed to ensure the PV system is operating as designed over its useful lifetime. To mitigate risks to PV system availability and performance, standardized procedures for O&M activities are needed to ensure high reliability and long-term system bankability. Efforts are just getting underway to address the need for standard O&M procedures as PV gains a larger share of U.S. generation capacity. Due to the existing landscape of how and where PV is installed, including distributed generation from small and medium PV systems, as well as large, centralized utility-scale PV, O&M activities will require different levels of expertise and reporting, making standards even more important. This report summarizes recent efforts made by solar industry stakeholders to identify the existing standards and best practices applied to solar PV O&M activities, and determine the gaps that have yet to be, or are currently being addressed by industry.

  19. Sensor System for Long-term Recording of Photovoltaic (PV) IV-curves

    DEFF Research Database (Denmark)

    Paasch, Kasper; Nymand, Morten; Haase, Frerk

    The purpose of this paper is to present a recording system for long-term investigation of PV panel dynamics under partial shading conditions. The system is intended to be a low-cost system deployable for stand-alone field use and long-term data recording at PV-plants. Passing clouds will affect...

  20. Design of Energy Storage Control Strategy to Improve the PV System Power Quality

    DEFF Research Database (Denmark)

    Lei, Mingyu; Yang, Zilong; Wang, Yibo

    2016-01-01

    Random fluctuation of PV power is becoming a more and more serious problem affecting the power quality and stability of grid as the PV penetration keeps increasing recent years. Aiming at this problem, this paper proposed a control strategy of energy storage system based on Model Predictive Control...

  1. Review of solar PV policies, interventions and diffusion in East Africa

    DEFF Research Database (Denmark)

    Hansen, Ulrich Elmer; Pedersen, Mathilde Brix; Nygaard, Ivan

    2015-01-01

    Previous research on the diffusion of solar PV in Africa has mainly focused on solar home systems (SHS) in individual countries and thus overlooked developments in other PV market segments that have recently emerged. In contrast this paper adopts a regional perspective by reviewing developments...

  2. Draft genome sequences of pseudomonas syringae pv. syringae ALF3 isolated from alfalfa

    Science.gov (United States)

    We report the annotated draft genome of Pseudomonas syringae pv. syringae strain ALF3, isolated in Wyoming, USA. Comparison of this genome sequence with those of closely related strains of P. syringae pv. syringae adapted to other hosts will facilitate research into interactions between this pathoge...

  3. Comparison of the indoor performance of 12 commercial PV products by a simple model

    NARCIS (Netherlands)

    Apostolou, G.; Reinders, A.H.M.E.; Verwaal, M.

    2016-01-01

    This article presents a simple comparative model which has been developed for the estimation of the performance of photovoltaic (PV) products' cells in indoor environments. The model predicts the performance of PV solar cells, as a function of the distance from a spectrum of artificial (fluorescent

  4. System engineering and design of LSC-PV for outdoor lighting applications

    NARCIS (Netherlands)

    Viswanathan, B.; Reinders, A.H.M.E.; De Boer, D.K.G.; Ras, A.; Zahn, H.; Desmet, L.

    2012-01-01

    Solar photovoltaic outdoor lighting applications usually comprise flat plate PV modules mounted on top of a light pole. In our paper instead, it is thought of to design the light pole as a luminescent solar concentrator photovoltaic (LSC-PV) module with solar cell strips and hence reduce costs of si

  5. Wind effect on PV module temperature: Analysis of different techniques for an accurate estimation.

    Science.gov (United States)

    Schwingshackl, Clemens; Petitta, Marcello; Ernst Wagner, Jochen; Belluardo, Giorgio; Moser, David; Castelli, Mariapina; Zebisch, Marc; Tetzlaff, Anke

    2013-04-01

    In this abstract a study on the influence of wind to model the PV module temperature is presented. This study is carried out in the framework of the PV-Alps INTERREG project in which the potential of different photovoltaic technologies is analysed for alpine regions. The PV module temperature depends on different parameters, such as ambient temperature, irradiance, wind speed and PV technology [1]. In most models, a very simple approach is used, where the PV module temperature is calculated from NOCT (nominal operating cell temperature), ambient temperature and irradiance alone [2]. In this study the influence of wind speed on the PV module temperature was investigated. First, different approaches suggested by various authors were tested [1], [2], [3], [4], [5]. For our analysis, temperature, irradiance and wind data from a PV test facility at the airport Bolzano (South Tyrol, Italy) from the EURAC Institute of Renewable Energies were used. The PV module temperature was calculated with different models and compared to the measured PV module temperature at the single panels. The best results were achieved with the approach suggested by Skoplaki et al. [1]. Preliminary results indicate that for all PV technologies which were tested (monocrystalline, amorphous, microcrystalline and polycrystalline silicon and cadmium telluride), modelled and measured PV module temperatures show a higher agreement (RMSE about 3-4 K) compared to standard approaches in which wind is not considered. For further investigation the in-situ measured wind velocities were replaced with wind data from numerical weather forecast models (ECMWF, reanalysis fields). Our results show that the PV module temperature calculated with wind data from ECMWF is still in very good agreement with the measured one (R² > 0.9 for all technologies). Compared to the previous analysis, we find comparable mean values and an increasing standard deviation. These results open a promising approach for PV module

  6. Computer Modelling and Simulation of Solar PV Array Characteristics

    Science.gov (United States)

    Gautam, Nalin Kumar

    2003-02-01

    The main objective of my PhD research work was to study the behaviour of inter-connected solar photovoltaic (PV) arrays. The approach involved the construction of mathematical models to investigate different types of research problems related to the energy yield, fault tolerance, efficiency and optimal sizing of inter-connected solar PV array systems. My research work can be divided into four different types of research problems: 1. Modeling of inter-connected solar PV array systems to investigate their electrical behavior, 2. Modeling of different inter-connected solar PV array networks to predict their expected operational lifetimes, 3. Modeling solar radiation estimation and its variability, and 4. Modeling of a coupled system to estimate the size of PV array and battery-bank in the stand-alone inter-connected solar PV system where the solar PV system depends on a system providing solar radiant energy. The successful application of mathematics to the above-m entioned problems entailed three phases: 1. The formulation of the problem in a mathematical form using numerical, optimization, probabilistic and statistical methods / techniques, 2. The translation of mathematical models using C++ to simulate them on a computer, and 3. The interpretation of the results to see how closely they correlated with the real data. Array is the most cost-intensive component of the solar PV system. Since the electrical performances as well as life properties of an array are highly sensitive to field conditions, different characteristics of the arrays, such as energy yield, operational lifetime, collector orientation, and optimal sizing were investigated in order to improve their efficiency, fault-tolerance and reliability. Three solar cell interconnection configurations in the array - series-parallel, total-cross-tied, and bridge-linked, were considered. The electrical characteristics of these configurations were investigated to find out one that is comparatively less susceptible to

  7. Simplified Method for Modeling the Impact of Arbitrary Partial Shading Conditions on PV Array Performance: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    MacAlpine, Sara; Deline, Chris

    2015-09-15

    It is often difficult to model the effects of partial shading conditions on PV array performance, as shade losses are nonlinear and depend heavily on a system's particular configuration. This work describes and implements a simple method for modeling shade loss: a database of shade impact results (loss percentages), generated using a validated, detailed simulation tool and encompassing a wide variety of shading scenarios. The database is intended to predict shading losses in crystalline silicon PV arrays and is accessed using basic inputs generally available in any PV simulation tool. Performance predictions using the database are within 1-2% of measured data for several partially shaded PV systems, and within 1% of those predicted by the full, detailed simulation tool on an annual basis. The shade loss database shows potential to considerably improve performance prediction for partially shaded PV systems.

  8. Optimal Sizing and Design of Stand-Alone PV System Supplying Gas Well in Delta Egypt

    Directory of Open Access Journals (Sweden)

    Emad Ahmed Sweelem

    2015-01-01

    Full Text Available This paper presents a design for a standalone photovoltaic (PV system to provide the required electricity for a gas well located in Delta Egypt. The complete design steps for the proposed gas well loads are carried out. Site radiation data and the electrical load data of a typical gas well in the considered site are taken into account during the design steps. The reliability of the system is quantified by the loss of load probability. A computer program is developed to simulate the PV system behavior and to numerically find an optimal combination of PV array and battery bank for the design of stand-alone photovoltaic systems in terms of reliability. Simulations results showed that a value of loss of load probability LLP = 0 can be met by several combinations of PV array and battery storage. This paper describes the design steps in stand alone photovoltaic system that include sizing of PV modules, battery storages and charge controller.

  9. PSA Solar furnace: A facility for testing PV cells under concentrated solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Reche, J.; Canadas, I.; Sanchez, M.; Ballestrin, J.; Yebra, L.; Monterreal, R.; Rodriguez, J.; Garcia, G. [Concentration Solar Technologies, Plataforma Solar de Almeria-CIEMAT P.O. Box 22, Tabernas, E-04200 (Almeria) (Spain); Alonso, M.; Chenlo, F. [Photovoltaic Components and Systems, Renewable Energies Department-CIEMAT Avda. Complutense, 22, Madrid, E-28040 (Spain)

    2006-09-22

    The Plataforma Solar de Almeria (PSA), the largest centre for research, development and testing of concentration solar thermal technologies in Europe, has started to apply its knowledge, facilities and resources to development of the Concentration PV technology in an EU-funded project HiConPV. A facility for testing PV cells under solar radiation concentrated up to 2000x has recently been completed. The advantages of this facility are that, since it is illuminated by solar radiation, it is possible to obtain the appropriate cell spectral response directly, and the flash tests can be combined with prolonged PV-cell irradiation on large surfaces (up to 150cm{sup 2}), so the thermal response of the PV cell can be evaluated simultaneously. (author)

  10. Photovoltaic module V-I and P-V characterization through instrumentation control toolkit of MATLAB

    Directory of Open Access Journals (Sweden)

    Genci Sharko

    2011-11-01

    Full Text Available This paper describes one experimental method for determining the V-I and P-V characteristic of the photovoltaic modules. The short-circuit current (Isc, open-circuit voltage (Voc and the filling coefficient are measured, also. Direct characteristics of V-I and P-V curves under solar irradiance are measured and graphed in real time with system proposed for this reason. It describes the development of an automated monitoring system for a solar PV plant based on the use of Instrumentation Control Toolkit of MatLab Software. PV modules still have relatively low conversion efficiency; therefore, determining and controlling maximum power point tracking (MPPT for the solar array is essential in a PV system.

  11. A Best Practice for Developing Availability Guarantee Language in Photovoltaic (PV) O&M Agreements.

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Balfour, John [High Performance PV, Phoenix, AZ (United States)

    2015-11-01

    This document outlines the foundation for developing language that can be utilized in an Equipment Availability Guarantee, typically included in an O&M services agreement between a PV system or plant owner and an O&M services provider, or operator. Many of the current PV O&M service agreement Availability Guarantees are based on contracts used for traditional power generation, which create challenges for owners and operators due to the variable nature of grid-tied photovoltaic generating technologies. This report documents language used in early PV availability guarantees and presents best practices and equations that can be used to more openly communicate how the reliability of the PV system and plant equipment can be expressed in an availability guarantee. This work will improve the bankability of PV systems by providing greater transparency into the equipment reliability state to all parties involved in an O&M services contract.

  12. A Sensorless Power Reserve Control Strategy for Two-Stage Grid-Connected PV Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    Due to the still increasing penetration of grid-connected Photovoltaic (PV) systems, advanced active power control functionalities have been introduced in grid regulations. A power reserve control, where namely the active power from the PV panels is reserved during operation, is required for grid...... to achieve the power reserve. In this method, the solar irradiance and temperature measurements that have been used in conventional power reserve control schemes to estimate the available PV power are not required, and thereby being a sensorless approach with reduced cost. Experimental tests have been...... support. In this paper, a cost-effective solution to realize the power reserve for two-stage grid-connected PV systems is proposed. The proposed solution routinely employs a Maximum Power Point Tracking (MPPT) control to estimate the available PV power and a Constant Power Generation (CPG) control...

  13. Photovoltaic/thermal solar hybrid system with bifacial PV module and transparent plane collector

    Energy Technology Data Exchange (ETDEWEB)

    Robles-Ocampo, B. [Instituto Tecnologico de Celaya, Celaya 11111, Guanajuato (Mexico); CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Ruiz-Vasquez, E.; Canseco-Sanchez, H. [Instituto Tecnologico de Oaxaca, Oaxaca 68030, Oaxaca (Mexico); CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Cornejo-Meza, R.C. [Instituto Tecnologico de Tepic, av. Tecnologico 2595, Tepic 63175, Nayarit (Mexico); CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Trapaga-Martinez, G.; Vorobiev, Y.V. [CINVESTAV-Queretaro, Libramiento Norponiente 2000, Unidad Queretaro, Fracc. Real de Juriquilla, Queretaro, 76230, QRO (Mexico); Garcia-Rodriguez, F.J. [Instituto Tecnologico de Celaya, Celaya 11111, Guanajuato (Mexico); Gonzalez-Hernandez, J. [CIMAV, Miguel de Cervantes 120, Chihuahua 31109, Chihuahua (Mexico)

    2007-12-14

    Electric energy production with photovoltaic (PV)/thermal solar hybrid systems can be enhanced with the employment of a bifacial PV module. Experimental model of a PV/thermal hybrid system with such a module was constructed and studied. To make use of both active surfaces of the bifacial PV module, we designed and made an original water-heating planar collector and a set of reflecting planes. The heat collector was transparent in the visible and near-infrared spectral regions, which makes it compatible with the PV module made of crystalline Si. The estimated overall solar energy utilization efficiency for the system related to the direct radiation flux is of the order of 60%, with an electric efficiency of 16.4%. (author)

  14. The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Nielsen, Kaspar Kirstein

    2015-01-01

    The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system is examined using an analytical model for four different types of commercial PVs and a commercial bismuth telluride TEG. The TEG is applied directly on the back of the PV, so that the two devices have...... the same temperature. The PVs considered are crystalline Si (c-Si), amorphous Si (a-Si), copper indium gallium (di) selenide (CIGS) and cadmium telluride (CdTe) cells. The degradation of PV performance with temperature is shown to dominate the increase in power produced by the TEG, due to the low...... efficiency of the TEG. For c-Si, CIGS and CdTe PV cells the combined system produces a lower power and has a lower efficiency than the PV alone, whereas for an a-Si cell the total system performance may be slightly increased by the TEG....

  15. The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system

    CERN Document Server

    Bjørk, R

    2015-01-01

    The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system is examined using an analytical model for four different types of commercial PVs and a commercial bismuth telluride TEG. The TEG is applied directly on the back of the PV, so that the two devices have the same temperature. The PVs considered are crystalline Si (c-Si), amorphous Si (a-Si), copper indium gallium (di)selenide (CIGS) and cadmium telluride (CdTe) cells. The degradation of PV performance with temperature is shown to dominate the increase in power produced by the TEG, due to the low efficiency of the TEG. For c-Si, CIGS and CdTe PV cells the combined system produces a lower power and has a lower efficiency than the PV alone, whereas for an a-Si cell the total system performance may be slightly increased by the TEG.

  16. Modeling Single-Phase PV HB-ZVR Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong;

    2011-01-01

    PLECS is used to model the PV H-bridge zero voltage rectifier (HB-ZVR) inverter connected to grid and good results are obtained. First, several common topologies of PV inverters are introduced. Then the unipolar PWM control strategy is described for PV HB-ZVR inverter. Third, PLECS is briefly...... introduced. Fourth, the modeling of PV HB-ZVR inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is very powerful tool to real power circuits and it is very easy to simulate LCL filter. They have also verified that the unipolar PWM control...... strategy is feasible to control the PV HB-ZVR inverter....

  17. Control of Grid Interactive PV Inverters for High Penetration in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan

    distorted conditions. Chapter 2, therefore; overviews the latest ancillary services such as real power reduction during over frequency/over voltage events and reactive power control for static grid voltage support function of PV inverters. In case of high density of PV integration, grid connection rules...... which do not consider interaction among multiple PV inverters with the grid may allow unlimited number of PV plant connections and lead to unstable network operation. Harmonic emissions from multiple inverters connected to the same feeder and resulting in a network resonance can be a good example......Regarding of high density deployment of PV installations in electricity grids, new technical challenges such as voltage rise, thermal loading of network components, voltage unbalance, harmonic interaction and fault current contributions are being added to tasks list of distribution system operators...

  18. Implementation and Test of an Online Embedded Grid Impedance Estimation Technique for PV Inverters

    DEFF Research Database (Denmark)

    Asiminoaei, Lucian; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    New and stronger power quality requirements are issued due to the increased amount of photovoltaic (PV) installations. In this paper different methods are used for continuous grid monitoring in PV inverters. By injecting a noncharacteristic harmonic current and measuring the grid voltage response...... it is possible to evaluate the grid impedance directly by the PV inverter, providing a fast and low-cost implementation. This principle theoretically provides an accurate result of the grid impedance but when using it in the context of PV integration, different implementation issues strongly affect the quality...... of the results. This paper also presents a new impedance estimation method including typical implementation problems encountered, and it also presents adopted solutions for online grid impedance measurement. Practical tests on an existing PV inverter validate the chosen solution....

  19. 1366 Project Silicon: Reclaiming US Silicon PV Leadership

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Adam [1366 Technologies, Bedford, MA (United States)

    2016-02-16

    1366 Technologies’ Project Silicon addresses two of the major goals of the DOE’s PV Manufacturing Initiative Part 2 program: 1) How to reclaim a strong silicon PV manufacturing presence and; 2) How to lower the levelized cost of electricity (“LCOE”) for solar to $0.05-$0.07/kWh, enabling wide-scale U.S. market adoption. To achieve these two goals, US companies must commercialize disruptive, high-value technologies that are capable of rapid scaling, defensible from foreign competition, and suited for US manufacturing. These are the aims of 1366 Technologies Direct Wafer ™ process. The research conducted during Project Silicon led to the first industrial scaling of 1366’s Direct Wafer™ process – an innovative, US-friendly (efficient, low-labor content) manufacturing process that destroys the main cost barrier limiting silicon PV cost-reductions: the 35-year-old grand challenge of making quality wafers (40% of the cost of modules) without the cost and waste of sawing. The SunPath program made it possible for 1366 Technologies to build its demonstration factory, a key and critical step in the Company’s evolution. The demonstration factory allowed 1366 to build every step of the process flow at production size, eliminating potential risk and ensuring the success of the Company’s subsequent scaling for a 1 GW factory to be constructed in Western New York in 2016 and 2017. Moreover, the commercial viability of the Direct Wafer process and its resulting wafers were established as 1366 formed key strategic partnerships, gained entry into the $8B/year multi-Si wafer market, and installed modules featuring Direct Wafer products – the veritable proving grounds for the technology. The program also contributed to the development of three Generation 3 Direct Wafer furnaces. These furnaces are the platform for copying intelligently and preparing our supply chain – large-scale expansion will not require a bigger machine but more machines. SunPath filled the

  20. Economic evaluation of a photovoltaic (PV) power generation system with battery; Battery wo heiyoshita taiyoko hatsuden system no keizaiseihyoka

    Energy Technology Data Exchange (ETDEWEB)

    Tomikura, S.; Kaya, Y. [Keio University, Tokyo (Japan)

    1997-01-30

    To improve the correlation characteristics between unstable output of PV system and demand, and to improve its economical value, use of battery was investigated. In this study, at first, solution of constrained optimization problem was derived in the case when the demand and PV output were defined by the continuous function, to obtain the break-even cost of PV system. To investigate the charge from PV in daytime or the charge from base power source at night, peak, middle and base power sources were considered. Finally, break-even cost of the PV system with battery was calculated as a trial using a multiple time zone model having PV and usual three power sources. As a result, the difference ranging from 25000 to 29000 yen in the break-even costs between PV and PV with battery was provided, which was considered to be a pure increase of the value using battery. 10 refs., 7 figs., 1 tab.

  1. Expressão dos genes nod de Rhizobium tropici, R. etli e R. leguminosarum bv. phaseoli e estabelecimento da nodulação do feijoeiro na presença de exsudatos de sementes de Mimosa flocculosa e Leucaena leucocephala

    Directory of Open Access Journals (Sweden)

    F. M. Mercante

    2000-06-01

    Full Text Available Na etapa inicial da troca de sinais moleculares entre macro e microssimbiontes, a interação do feijoeiro e estirpes de Rhizobium tropici, R. etli e R. leguminosarum bv. phaseoli foi avaliada pela expressão dos genes nod de estirpes bacterianas, contendo a fusão nodA::gusA. Esta avaliação foi efetuada por meio da atividade da enzima ß-glucuronidase, utilizando, como indutores, exsudatos liberados pelas sementes de Mimosa flocculosa e Leucaena leucocephala. Além disso, avaliou-se o efeito da adição desses exsudatos no estabelecimento da nodulação do feijoeiro, cv. Carioca. Nos testes "in vitro", a mistura de exsudatos de sementes de feijoeiro e M. flocculosa promoveu aumentos sinergísticos significativos na expressão dos genes nod, tanto das estirpes de R. tropici (CIAT 899/pGUS 32 e F 98.5/pGUS 32 quanto de R. etli (CFN 42/pGUS 32. Em condições controladas, a adição dos exsudatos, tanto de M. flocculosa quanto de L. leucocephala, proporcionou aumento significativo na nodulação inicial do feijoeiro, quando foi inoculada a estirpe CFN 42 (R. etli. A nodulação do feijoeiro cultivado em vasos com solo não foi inibida pelo suprimento de N-mineral, quando se inoculou a estirpe CIAT 899 (R. tropici e foram fornecidos exsudatos de sementes de M. flocculosa.

  2. An investigation of the maximum penetration level of a photovoltaic (PV) system into a traditional distribution grid

    Science.gov (United States)

    Chalise, Santosh

    Although solar photovoltaic (PV) systems have remained the fastest growing renewable power generating technology, variability as well as uncertainty in the output of PV plants is a significant issue. This rapid increase in PV grid-connected generation presents not only progress in clean energy but also challenges in integration with traditional electric power grids which were designed for transmission and distribution of power from central stations. Unlike conventional electric generators, PV panels do not have rotating parts and thus have no inertia. This potentially causes a problem when the solar irradiance incident upon a PV plant changes suddenly, for example, when scattered clouds pass quickly overhead. The output power of the PV plant may fluctuate nearly as rapidly as the incident irradiance. These rapid power output fluctuations may then cause voltage fluctuations, frequency fluctuations, and power quality issues. These power quality issues are more severe with increasing PV plant power output. This limits the maximum power output allowed from interconnected PV plants. Voltage regulation of a distribution system, a focus of this research, is a prime limiting factor in PV penetration levels. The IEEE 13-node test feeder, modeled and tested in the MATLAB/Simulink environment, was used as an example distribution feeder to analyze the maximum acceptable penetration of a PV plant. The effect of the PV plant's location was investigated, along with the addition of a VAR compensating device (a D-STATCOM in this case). The results were used to develop simple guidelines for determining an initial estimate of the maximum PV penetration level on a distribution feeder. For example, when no compensating devices are added to the system, a higher level of PV penetration is generally achieved by installing the PV plant close to the substation. The opposite is true when a VAR compensator is installed with the PV plant. In these cases, PV penetration levels over 50% may be

  3. Comparative analysis of PvPAP gene family and their functions in response to phosphorus deficiency in common bean.

    Directory of Open Access Journals (Sweden)

    Cuiyue Liang

    Full Text Available BACKGROUND: Purple acid phosphatases (PAPs play a vital role in adaptive strategies of plants to phosphorus (P deficiency. However, their functions in relation to P efficiency are fragmentary in common bean. PRINCIPAL FINDINGS: Five PvPAPs were isolated and sequenced in common bean. Phylogenetic analysis showed that PvPAPs could be classified into two groups, including a small group with low molecular mass, and a large group with high molecular mass. Among them, PvPAP3, PvPAP4 and PvPAP5 belong to the small group, while the other two belong to the large group. Transient expression of 35S:PvPAPs-GFP on onion epidermal cells verified the variations of subcellular localization among PvPAPs, suggesting functional diversities of PvPAPs in common bean. Quantitative PCR results showed that most PvPAPs were up-regulated by phosphate (Pi starvation. Among them, the expression of the small group PvPAPs responded more to Pi starvation, especially in the roots of G19833, the P-efficient genotype. However, only overexpressing PvPAP1 and PvPAP3 could result in significantly increased utilization of extracellular dNTPs in the transgenic bean hairy roots. Furthermore, overexpressing PvPAP3 in Arabidopsis enhanced both plant growth and total P content when dNTPs were supplied as the sole external P source. CONCLUSIONS: The results suggest that PvPAPs in bean varied in protein structure, response to P deficiency and subcellular localization. Among them, both PvPAP1 and PvPAP3 might function as utilization of extracellular dNTPs.

  4. An Optimized Combination of a Large Grid Connected PV System along with Battery Cells and a Diesel Generator

    OpenAIRE

    2016-01-01

    Environmental, economical and technical benefits of photovoltaic (PV) systems make them to be used in many countries. The main characteristic of PV systems is the fluctuations of their output power. Hence, high penetration of PV systems into electric network could be detrimental to overall system performance. Furthermore, the fluctuations in the output power of PV systems make it difficult to predict their output, and to consider them in generation planning of the units. The main objective of...

  5. Modeling the Impedance of Nanostructured PV in Simulink/matlab

    Science.gov (United States)

    Houshmand, Mohammad; Zandi, Mohammad. H.; Gorji, Nima E.

    2013-08-01

    Impedance measurement is a common method to study the electrical properties of thin film photovoltaics. For the first time, we use the MATLAB/Simulink environment to extract the complex impedance of the nanostructured heterojunction solar cells. The impedance magnitude, phase and Nyquist plot of the PV are simulated in LTI Viewer and Impedance versus Frequency analysis tools of SimPower GUI block of Simulink. We examined a variety of the equivalent circuits consisting of capacitance, series and shunt resistances representing the solar cell structure. The model uses the parameters with values reported in the literature at room temperature and zero bias. The effect of the additional capacitance and resistances in the equivalent circuits on the impedance components of the cells is considered by Simulink environment.

  6. Electronic processes in thin-film PV materials. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, P.C.; Chen, D.; Chen, S.L. [and others

    1998-07-01

    The electronic and optical processes in an important class of thin-film PV materials, hydrogenated amorphous silicon (a-Si:H) and related alloys, have been investigated using several experimental techniques designed for thin-film geometries. The experimental techniques include various magnetic resonance and optical spectroscopies and combinations of these two spectroscopies. Two-step optical excitation processes through the manifold of silicon dangling bond states have been identifies as important at low excitation energies. Local hydrogen motion has been studied using nuclear magnetic resonance techniques and found to be much more rapid than long range diffusion as measured by secondary ion mass spectroscopy. A new metastable effect has been found in a-Si:H films alloyed with sulfur. Spin-one optically excited states have been unambiguously identified using optically detected electron spin resonance. Local hydrogen bonding in microcrystalline silicon films has been studied using NMR.

  7. The reliability and stability of multijunction amorphous silicon PV modules

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, D.E. [Solarex, Newtown, PA (United States)

    1995-11-01

    Solarex is developing a manufacturing process for the commercial production of 8 ft{sup 2} multijunction amorphous silicon (a-Si) PV modules starting in 1996. The device structure used in these multijunction modules is: glass/textured tin oxide/p-i-n/p-i-n/ZnO/Al/EVA/Tedlar where the back junction of the tandem structure contains an amorphous silicon germanium alloy. As an interim step, 4 ft{sup 2} multijunction modules have been fabricated in a pilot production mode over the last several months. The distribution of initial conversion efficiencies for an engineering run of 67 modules (4 ft{sup 2}) is shown. Measurements recently performed at NREL indicate that the actual efficiencies are about 5% higher than those shown, and thus exhibit an average initial conversion efficiency of about 9.5%. The data indicates that the process is relatively robust since there were no modules with initial efficiencies less than 7.5%.

  8. Application ofBoost Inverter to Multi Input PV system

    Directory of Open Access Journals (Sweden)

    G.SHINYVIKRAM

    2014-11-01

    Full Text Available With the shortage of the energy and ever increasing of the oil price, research on the renewable and green energy sources, especially the solar arrays and the fuel cells, becomes more and more important. How to achieve high step- up and high efficiency DC/DC converters is the major consideration in the renewable power applications due to the low voltage of PV arrays and fuel cells. The conventional boost converters increase the harmonics rate and add an extra stage of power conversion. This paper proposes a boost dc-ac inverter that can invert and boost the output voltage in a single stage. In this paper the proposed boost dc-ac inverter is applied to the solar power panels and is simulated using Simulink. The output results of the boost inverter are worthy promising.

  9. Comparison of four MPPT techniques for PV systems

    Science.gov (United States)

    Atik, L.; Petit, P.; Sawicki, J. P.; Ternifi, Z. T.; Bachir, G.; Aillerie, M.

    2016-07-01

    The working behavior of a module / PV array is non-linear and highly dependent on working conditions. As a given condition, there is only one point at which the level of available power at its output is maximum. This point varies with time, enlightenment and temperature. To ensure optimum operation, the use of MPPT control allows us to extract the maximum power. This paper presents a comparative study of four widely-adopted MPPT algorithms, such as Perturb and Observe, Incremental Conductance, Measurements of the variation of the open circuit voltage or of the short-circuit current. Their performance is evaluated using, for all these techniques. In particular, this study compares the behaviors of each technique in presence of solar irradiation variations and temperature fluctuations. These MPPT techniques will be compared using the Matlab / Simulink tool.

  10. PV Degradation Methodology Comparison -- A Basis for a Standard

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, Dirk C.; Deceglie, Michael G.; Kurtz, Sarah R.

    2016-11-21

    What is the best method to determine long-term PV system performance and degradation rates? Ideally, one universally applicable methodology would be desirable so that a single number could be derived. However, data sets vary in their attributes and evidence is presented that defining two methodologies may be preferable. Monte Carlo simulations of artificial performance data allowed investigation of different methodologies and their respective confidence intervals. Tradeoffs between different approaches were delineated, elucidating as to why two separate approaches may need to be included in a standard. Regression approaches tend to be preferable when data sets are less contaminated by seasonality, noise and occurrence of outliers although robust regression can significantly improve the accuracy when outliers are present. In the presence of outliers, marked seasonality, or strong soiling events, year-on-year approaches tend to outperform regression approaches.

  11. Final Technical Report - Photovoltaics for You (PV4You) Program

    Energy Technology Data Exchange (ETDEWEB)

    Weissman, J. M. [Interstate Renewable Energy Council (IREC), New York, NY (United States); Sherwood, L. [Interstate Renewable Energy Council (IREC), New York, NY (United States); Pulaski, J. [Interstate Renewable Energy Council (IREC), New York, NY (United States); Cook, C. [Interstate Renewable Energy Council (IREC), New York, NY (United States); Kalland, S. [Interstate Renewable Energy Council (IREC), New York, NY (United States); Haynes, J. [Interstate Renewable Energy Council (IREC), New York, NY (United States)

    2005-08-14

    In September 2000, the Interstate Renewable Energy Council (IREC) began its 5-year work on contract # DE-FGO3-00SF22116, the Photovoltaics for You (PV4You) Project. The objective was to develop and distribute information on photovoltaics and to educate key stakeholder groups including state government agencies, local government offices, consumer representative agencies, school officials and students, and Million Solar Roofs Partnerships. In addition, the project was to identify barriers to the deployment of photovoltaics and implement strategies to overcome them. Information dissemination and education was accomplished by publishing newsletters; creating a base of information, guides, and models on the www.irecusa.org and the www.millionsolarroofs.org web sites; convening workshops and seminars; engaging multiple stakeholders; and widening the solar network to include new consumers and decision makers. Two major web sites were maintained throughout the project cycle. The www.irecusa.org web site housed dedicated pages for Connecting to the Grid, Schools Going Solar, Community Outreach, and Certification & Training. The www.millionsolarroofs.org web site was created to serve the MSR Partnerships with news, interviews, key documents, and resource material. Through the course of this grant, the Interstate Renewable Energy Council has been supporting the Department of Energy's solar energy program goals by providing the Department with expertise services for their network of city, state, and community stakeholders. IREC has been the leading force at the state and federal levels regarding net metering and interconnection policy for photovoltaic systems. The principal goal and benefit of the interconnection and net metering work is to lower both barriers and cost for the installation of PV. IREC typically plays a leadership role among small generator stakeholders and has come to be relied upon for its expertise by industry and regulators. IREC also took a leadership

  12. Modified Multilevel Inverter Topology for Grid Connected Pv Systems

    Directory of Open Access Journals (Sweden)

    Dhivya Balakrishnan

    2013-10-01

    Full Text Available Multilevel converters offer high power capability, associated with lower output harmonics and lower commutation losses. Their main disadvantage is their complexity, requiring a great number of power devices and passive components, and a rather complex control circuitry. This paper proposes a single-phase seven- level inverter for grid connected PV systems, with a novel pulse width-modulated (PWM control scheme. Three reference signals that are identical to each other with an offset that is equivalent to the amplitude of the triangular carrier signal were used to generate the PWM signals. The inverter is capable of producing seven levels of output-voltage levels from the dc supply voltage. This paper proposes a new multilevel inverter topology using an H-bridge output stage with two bidirectional auxiliary switches. The new topology produces a significant reduction in the number of power devices and capacitors required to implement a multilevel output using the Asymmetric Cascade configuration.

  13. Testing QCD factorization and charming penguins in charmless B -> PV

    CERN Document Server

    Aleksan, Roy; Morénas, V; Pène, O; Safir, A S

    2002-01-01

    We try a global fit of the experimental branching ratios and CP-asymmetries of the charmless B -> PV decays according to QCD factorization. We find it impossible to reach a satisfactory agreement, the confidence level (CL) of the best is smaller than .1 %. The main reason for this failure is the difficulty to accommodate several large experimental branching ratios of the strange channels. Furthermore, experiment was not able to exclude a large direct CP asymmetry in B-bar0 -> rho sup +pi sup - which is predicted very small by QCD factorization. Trying a fit with QCD factorization complemented by a charming-penguin inspired model we reach a best fit which is not excluded by experiment (CL of about 8 %) but is not fully convincing. These negative results must be tempered by the remark that some of the experimental data used are recent and might still evolve significantly.

  14. Optimal Demand Response of Smart Home with PV Generators

    Directory of Open Access Journals (Sweden)

    Chao-Rong Chen

    2014-01-01

    Full Text Available Demand response (DR is used mainly to help to schedule a customer’s power utilization based on the electricity price that is announced by the power distribution company so that both demand and supply can optimally benefit. The work proposes a users’ load model and the interior point method for optimal scheduling with elastic power utilization to minimize power price. The interior point method has the advantages of rapid convergence and robustness. Customers can not only use PV generators and battery sets as backup power sources, but also benefit from green energy. As revealed by the results herein, the use of elastic power utilization time intervals enables customers to pay less power price.

  15. Lifetime of lithium-ion batteries for PV applications

    Energy Technology Data Exchange (ETDEWEB)

    Brand, Martin; Keil, Peter; Jossen, Andreas [Technische Univ. Muenchen (DE). Inst. for Electrical Energy Storage Technology (EES); Spaeth, Volker [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Ulm (Germany)

    2010-07-01

    Two different types of lithium-ion batteries are investigated for use in photovoltaic stand alone systems. To minimize the spread of the cells, small, mass produced cells and no large cells were used for our investigations. As technologies Lithium-Iron-Phosphate (LFP) and a cell with blended LiCoO{sub 2}, LiMn{sub 2}O{sub 4} and LiNi{sub X}Co{sub Y}Al{sub Z}O{sub 2} (NMC blend) were used. With each cell technology different storage and cycling tests were started 2 years ago. Here the depth of discharge, the average state of charge and the temperature were varied. The results show that both battery technologies have different ageing characteristics. Most difference is in the influence of the average state of charge. The other important result is that in case of PV-stand alone operation, calendar ageing is more significant than cycle life ageing. (orig.)

  16. High Performance Packaging Solutions for Low Cost, Reliable PV Modules: Final Subcontract Report, 26 May 2005 - 30 November 2008

    Energy Technology Data Exchange (ETDEWEB)

    Keotla, B. M.; Marinik, B. J.

    2009-06-01

    During this research effort, Dow Corning Corporation has addressed the PV manufacturing goals of: (i) improving PV manufacturing processes and equipment; (ii) accelerating manufacturing cost reductions of PV modules; (iii) increasing commercial product performance and reliability; and (iv) scaling up U.S. manufacturing capacity.

  17. Evaluation of the Performance of the PVUSA Rating Methodology Applied to Dual Junction PV Technology: Preprint (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D. R.

    2009-07-01

    The PVUSA (Photovoltaics for Utility Scale Applications) project in the 1990's developed a rating methodology for PV performance evaluation which has become popular, and even incorporated into concentrating PV rating standards This report apply that method to rack-mounted dual-junction PV system, and produces a system rating.

  18. First report of the crucifer pathogen Pseudomonas cannabina pv. alisalensis causing bacterial blight on radish (Raphanus sativus) in Germany

    Science.gov (United States)

    Pseudomonas cannabina pv. alisalensis is a severe pathogen of crucifers across the U.S. We compared a strain isolated from diseased radish (Raphanus sativus) in Germany to pathotypes and additional strains of P. cannabina pv. alisalensis and P. syringae pv. maculicola. We demonstrated that the patho...

  19. Comparison of the complete genome sequences of Pseudomonas syringae pv. syringae B728a and pv. tomato DC3000

    Energy Technology Data Exchange (ETDEWEB)

    Feil, Helene [University of California, Berkeley; Feil, William [University of California, Berkeley; Chain, Patrick S. G. [Lawrence Livermore National Laboratory (LLNL); Larimer, Frank W [ORNL; DiBartolo, Genevieve [U.S. Department of Energy, Joint Genome Institute; Copeland, A [U.S. Department of Energy, Joint Genome Institute; Lykidis, A [U.S. Department of Energy, Joint Genome Institute; Trong, Stephen [U.S. Department of Energy, Joint Genome Institute; Nolan, Matt [U.S. Department of Energy, Joint Genome Institute; Goltsman, Eugene [U.S. Department of Energy, Joint Genome Institute; Thiel, James [U.S. Department of Energy, Joint Genome Institute; Malfatti, Stephanie [Lawrence Livermore National Laboratory (LLNL); Loper, Joyce E. [U.S. Department of Agriculture, Agricultural Research Service; Detter, J C [U.S. Department of Energy, Joint Genome Institute; Lapidus, Alla L. [U.S. Department of Energy, Joint Genome Institute; Land, Miriam L [ORNL; Richardson, P M [U.S. Department of Energy, Joint Genome Institute; Kyrpides, Nikos C [U.S. Department of Energy, Joint Genome Institute; Ivanova, N [U.S. Department of Energy, Joint Genome Institute; Lindow, Steven E. [University of California, Berkeley

    2005-01-01

    The complete genomic sequence of Pseudomonas syringae pv. syringae B728a (Pss B728a) has been determined and is compared with that of A syringae pv. tomato DC3000 (Pst DC3000). The two pathovars of this economically important species of plant pathogenic bacteria differ in host range and other interactions with plants, with Pss having a more pronounced epiphytic stage of growth and higher abiotic stress tolerance and Pst DC3000 having a more pronounced apoplastic growth habitat. The Pss B728a genome (6.1 Mb) contains a circular chromosome and no plasmid, whereas the Pst DC3000 genome is 6.5 mbp in size, composed of a circular chromosome and two plasmids. Although a high degree of similarity exists between the two sequenced Pseudomonads, 976 protein-encoding genes are unique to Pss B728a when compared with Pst DC3000, including large genomic islands likely to contribute to virulence and host specificity. Over 375 repetitive extragenic palindromic sequences unique to Pss B728a when compared with Pst DC3000 are widely distributed throughout the chromosome except in 14 genomic islands, which generally had lower GC content than the genome as a whole. Content of the genomic islands varies, with one containing a prophage and another the plasmid pKLC102 of Pseudomonas aeruginosa PAO1. Among the 976 genes of Pss B728a with no counterpart in Pst DC3000 are those encoding for syringopeptin, syringomycin, indole acetic acid biosynthesis, arginine degradation, and production of ice nuclei. The genomic comparison suggests that several unique genes for Pss B728a such as ectoine synthase, DNA repair, and antibiotic production may contribute to the epiphytic fitness and stress tolerance of this organism.

  20. Interconnecting PV on New York City's Secondary Network Distribution System

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, K; Coddington, M; Burman, K; Hayter, S; Kroposki, B; Watson, and A

    2009-11-01

    The U.S. Department of Energy (DOE) has teamed with cities across the country through the Solar America Cities (SAC) partnership program to help reduce barriers and accelerate implementation of solar energy. The New York City SAC team is a partnership between the City University of New York (CUNY), the New York City Mayor s Office of Long-term Planning and Sustainability, and the New York City Economic Development Corporation (NYCEDC).The New York City SAC team is working with DOE s National Renewable Energy Laboratory (NREL) and Con Edison, the local utility, to develop a roadmap for photovoltaic (PV) installations in the five boroughs. The city set a goal to increase its installed PV capacity from1.1 MW in 2005 to 8.1 MW by 2015 (the maximum allowed in 2005). A key barrier to reaching this goal, however, is the complexity of the interconnection process with the local utility. Unique challenges are associated with connecting distributed PV systems to secondary network distribution systems (simplified to networks in this report). Although most areas of the country use simpler radial distribution systems to distribute electricity, larger metropolitan areas like New York City typically use networks to increase reliability in large load centers. Unlike the radial distribution system, where each customer receives power through a single line, a network uses a grid of interconnected lines to deliver power to each customer through several parallel circuits and sources. This redundancy improves reliability, but it also requires more complicated coordination and protection schemes that can be disrupted by energy exported from distributed PV systems. Currently, Con Edison studies each potential PV system in New York City to evaluate the system s impact on the network, but this is time consuming for utility engineers and may delay the customer s project or add cost for larger installations. City leaders would like to streamline this process to facilitate faster, simpler, and