WorldWideScience

Sample records for axial tomography evidence

  1. The Role of Computed Axial Tomography in the Study of the Child with Minimal Brain Dysfunction.

    Science.gov (United States)

    Thompson, J. S.; And Others

    1980-01-01

    It was concluded that computed axial tomography of the brain is not a necessary screening procedure in the evaluation of the child with minimal brain dysfunction or learning disabilities unless there is evidence of a focal neurologic deficit. (Author)

  2. Medullary sponge kidney on axial computed tomography

    International Nuclear Information System (INIS)

    Ginalski, J.-M.; Schnyder, Pierre; Portmann, Luc; Jaeger, Philippe

    1991-01-01

    To evaluate features of medullary sponge kidney (MSK) on computed tomography (CT), 4-mm-thick axial slices without intravenous contrast material were 1st made in 13 patients through 24 kidneys which showed images of MSK on excretory urograms. On CT, papillary calcifications were found in 11 kidneys. In 5 of these, the calcifications were not detectable on plain films. Some hyperdense papillae (attenuation value 55-70 Hounsfield units) without calcification were found in 4 other kidneys. 9 kidneys appeared normal. 10 of the 14 kidneys were reexamined by a 2nd series of 4-mm-thick axial slices, 5 min after intravenous injection of 50 ml of Urografin. Images suggesting possible ectasia of precaliceal tubules were found in only 4 kidneys. These images appear much less obvious and characteristic on CT than on excretory urogram and do nothing more than suggest the possibility of MSK. In conclusion, the sensitivity of CT in the detection of MSK is markedly lower than that of excretory urography. In the most florid cases of the disease, CT can only show images suggesting the possibility of MSK. On the other hand, CT appears much more sensitive than plain films and tomograms of excretory in the detection of papillary calcifications, the most frequent complication of MSK. (author). 13 refs.; 3 figs

  3. Axial tomography in live cell laser microscopy

    Science.gov (United States)

    Richter, Verena; Bruns, Sarah; Bruns, Thomas; Weber, Petra; Wagner, Michael; Cremer, Christoph; Schneckenburger, Herbert

    2017-09-01

    Single cell microscopy in a three-dimensional (3-D) environment is reported. Cells are grown in an agarose culture gel, located within microcapillaries and observed from different sides after adaptation of an innovative device for sample rotation. Thus, z-stacks can be recorded by confocal microscopy in different directions and used for illustration in 3-D. This gives additional information, since cells or organelles that appear superimposed in one direction, may be well resolved in another one. The method is tested and validated with single cells expressing a membrane or a mitochondrially associated green fluorescent protein, or cells accumulating fluorescent quantum dots. In addition, axial tomography supports measurements of cellular uptake and distribution of the anticancer drug doxorubicin in the nucleus (2 to 6 h after incubation) or the cytoplasm (24 h). This paper discusses that upon cell rotation an enhanced optical resolution in lateral direction compared to axial direction can be utilized to obtain an improved effective 3-D resolution, which represents an important step toward super-resolution microscopy of living cells.

  4. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  5. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  6. Axial myopia in computed and magnetic resonance tomography

    Energy Technology Data Exchange (ETDEWEB)

    Beyer-Enke, S.A.; Goerich, J.; Gamroth, A.

    1987-08-01

    The case of a 44-year old woman suffering from amblyopia on the left eye with unilateral proptosis caused by axial (progressive) myopia is presented. The clinical and radiological findings were discussed in reference to the literature. The diagnosis was established by ruling out neoplastic, inflammatory or endocrine causes for the exophtalmos. CT and MR scans revealed an enlarged left globe without evidence of orbital masses. The findings were regarded as typical for the diagnosis at axial myopia.

  7. Axial positrons emission tomography: from mouse to human brain imaging

    International Nuclear Information System (INIS)

    Brard, Emmanuel

    2013-01-01

    Positrons emission tomography is a nuclear imaging technics using nuclear decays. It is used both in clinical and preclinical studies. The later requires the use of small animals such as the mouse. The objective is to obtain the best signal with the best spatial resolution. Yet, a weight ratio between humans and mice indicates the need of a sub-millimeter resolution. A conventional scanner is based on detection modules surrounding the object to image and arranged perpendicularly. This implies a strong relationship between efficiency and spatial resolution. This work focuses on the axial geometry in which detection modules are arranged parallel to the object. This limits the relationship between the figures of merit, leading to both high spatial resolution and efficiency. The simulations of prototypes showed great perspectives in term of sub-millimeter resolution with efficiencies of 15 or 40% according to the scanner's axial extension. These results indicate great perspectives for both clinical and preclinical imaging. (author)

  8. A review of X-ray computed axial tomography

    International Nuclear Information System (INIS)

    Schmidt, M.

    1989-01-01

    A review of Computed axial tomography (CAT) scanning literature outlining the theoretical and practical aspects of this technique with application in both medical diagnosis and industrial non-destructive inspection (NDI) is presented. Practical aspects of CAT scanning discussed include : radiation sources, currently available spatial and contrast resolution limits and the evolution of the computerized tomography (CT) system. It was found that monochromatic gamma rays are preferred to X-rays, especially for very high density materials, and that in medical CAT scanning, the special resolution is only, 0.5 mm while spatial resolutions of less than 50μm have been achieved in NDI. An increased number of scientific and industrial applications are anticipated (e.g. for studying sintering reactions), as the capital cost of CAT scanning decreased. 13 refs., 9 figs., 2 tabs

  9. Computerized axial tomography in the detection of brain damage

    International Nuclear Information System (INIS)

    Cala, L.A.; Mastaglia, F.L.

    1980-01-01

    The cranial computerized axial tomography (CAT) findings in groups of patients with epilepsy, migraine, hypertension, and other general medical disorders have been reviewed to assess the frequency and patterns of focal and diffuse brain damage. In addition to demonstrating focal lesions in a proportion of patients with seizures and in patients presenting with a stroke, the CAT scan showed a premature degree of cerebral atrophy in an appreciable proportion of patients with long-standing epilepsy, hypertension and diabetes, and in some patients with migraine, valvular and ischaemic heart disease, chronic obstructive airways disease, and chronic renal failure. The value of CAT as a means of screening for brain damage in groups of individuals at risk is discussed

  10. Target localization on standard axial images in computed tomography (CT) stereotaxis for functional neurosurgery - a technical note

    International Nuclear Information System (INIS)

    Patil, A.-A.

    1986-01-01

    A simple technique for marking functional neurosurgery target on computed tomography (CT) axial image is described. This permits the use of standard axial image for computed tomography (CT) stereotaxis in functional neurosurgery. (Author)

  11. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  12. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  13. Transverse axial plane anatomy of the temporal bone employing high spatial resolution computed tomography

    International Nuclear Information System (INIS)

    Russell, E.J.; Koslow, M.; Lasjaunias, P.; Bergeron, R.T.; Chase, N.

    1982-01-01

    Anatomical relationships of temporal bone structures are demonstrated by thin section edge detection computed tomography. Many otic structures are best appreciated in axial view, but reorientation to anatomy as seen in this plane is needed for optimal diagnosis. A level by level review of key structure is presented toward this end. The limitations and advantages of computed tomography are discussed. (orig.)

  14. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin V, J.C.; Falcony, C.; Azorin N, J.

    2000-01-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  15. Three-dimensional S-wave tomography under Axial Seamount

    Science.gov (United States)

    Baillard, C.; Wilcock, W. S. D.; Arnulf, A. F.; Tolstoy, M.; Waldhauser, F.

    2017-12-01

    Axial Seamount is a submarine volcano located at the intersection of the Juande Fuca Ridge and the Cobb-Eickelberg hotspot 500 km off the coast of thenorthwestern United States. The seamount, which rises 1 km above the seafloor, ischaracterized by a shallow caldera that is elongated in the N-S direction, measure 8km by 3 km and sits on top of a 14 km by 3 km magma reservoir. Two eruptive eventsin 1998 and 2011 motivated the deployment in 2014 of a real time cabled observatorywithin the Axial caldera, as part of the Ocean Observatories Initiative (OOI).Theobservatory includes a network of seven seismometers that span the southern half ofthe caldera. Five months after the observatory came on-line in November 2014, thevolcano erupted on April 24, 2015. Well over 100,000 events were located in thevicinity of the caldera, delineating an outward dipping ring fault that extends fromnear the surface to the magma body at 2 km depth and which accommodatesinflation and deflation of the volcano.The initial earthquake locations have beenobtained with a one-dimensional velocity model but the travel time residuals suggeststrong heterogeneities. A three-dimensional P-wave velocity model, obtained bycombining multichannel and ocean bottom seismometer refraction data, is being usedto refine locations but the three-dimensional S-wave structure is presently unknown.In most mid-ocean ridge settings, the distribution of earthquakes is not conducive forjoint inversions for S-wave velocity and hypocentral parameters because there are fewcrossing ray paths but at Axial the presence of a ring fault that is seismically active atall depths on both the east and west side of the caldera, provides a reasonablegeometry for such efforts. We will present the results of joint inversions that assumethe existing three-dimensional P wave velocity model and solve for VP/VS structure andhypocentral parameters using LOTOS, an algorithm that solves the forward problemusing ray bending.The resulting model

  16. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  17. Pericardial cyst diagnosed by echocardiogram and computerized axial tomography. Presentation of a case

    International Nuclear Information System (INIS)

    Porro, N.; Castells, R.; Borges, A.

    1988-01-01

    A case of pericardial celomic cyst in a 50 years-old, asymptomatic female patient is presented. The diagnosis was performed by X rays of the thorax, echocardiogram and computerized axial tomography. The value of these examinations was emphasized, since they allow the detection of the presence of juxtacardiac tumors and their nature. The treatment was surgical, as it is recommended, practicing exeresis of the cyst, which measured 6x3 in diameter. No complications occurred. Photos are shown

  18. Testing objects in Computerized Axial Tomography. Contributions to the Spanish Protocol on quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Villaescusa, J.I.; Campayo, J.M.

    1995-01-01

    In the provisional version of the Spanish Protocol about the technical aspects of Quality Control in Radiodiagnostic,SEFM-SEPR 1993, it is dedicated a section to Computerized Axial tomography, establishing a total of eleven technical parameters of the equipment for examination. The present work describes the practical use of the Protocol using various types of Test Object. The authors also propose new tests that should be considered in the final version of the Spanish Protocol. (Author)

  19. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters; Medicion del perfil de dosis en equipos de tomografia axial computarizada usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Azorin V, J.C.; Falcony, C.; Azorin N, J. [Centro de Investigacion en Ciencia y Tecnologia Avanzada, IPN, 07000 Mexico D.F. (Mexico)

    2000-07-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  20. Dual-channel phase-contrast spectral optical coherence tomography for simultaneously measuring axial and normal to B-scan off-axial displacements

    Science.gov (United States)

    Dong, Bo; Zhang, Yun; Ye, Shuangli; Zhou, Yanzhou; He, Zhaoshui; Xie, Shengli

    2017-09-01

    A dual-channel phase-contrast spectral optical coherence tomography (DPC-SOCT) method is proposed for measuring axial and normal to B-scan off-axial displacements inside weakly scattering translucent materials. By employing a dual-channel observation structure with depth multiplexing, only one shot before and one shot after the object deformation are required for simultaneously measuring the displacements. To validate the method, a DPC-SOCT system was built and axial and normal to B-scan off-axial displacements inside polymer films were measured at 20 frames per second. The results suggest that the method can be used for investigating inner mechanical properties of materials under different loads. In the future, a method for all orthogonal measurement of displacement components will be developed.

  1. Study of the human encephalon morphology by computerized axial tomography in neurological diseases

    International Nuclear Information System (INIS)

    Loynaz Fernandez, Clara Silvia; Milan Companioni, Daile; Gomez Padron, Ivo; Alvarez Leon, Oladys; Espinosa Quiros, Desiderio

    2001-01-01

    Since the middle of the last century, the study of the human encephalon morphology has been of great interest for the researchers. With the introduction of the computerized axial tomography in 1974, it was possible to expand the knowledge about this area and at the same time provide information on the structural lesions that are pathologies of great psychosocial repercussion like epilepsy and Parkinsonism. This paper used 90 tomographic studies on people aged 20-80 years. A series of linear measurements were made and statistically processed. The results showed variations in linear measurements among control, epileptic and Parkinsonian subjects

  2. Complementary medicine for axial spondyloarthritis: is there any scientific evidence?

    Science.gov (United States)

    Danve, Abhijeet; Deodhar, Atul

    2018-04-09

    Majority of patients with axial spondyloarthritis (axSpA) report use of complementary and alternative medicine (CAM) therapies before and even after the diagnosis, due to perceived efficacy and wide-spread belief that these modalities lack side effects. In this review, we describe the available scientific evidence for the CAM therapies in axSpA. Clinical trials of the CAM therapies in axSpA are generally hampered by small sample size, short duration, difficulties in blinding, lack of control groups and strong placebo effect. Nonetheless, exercise programs like Pilates and mind-body techniques such as Tai Chi may have favorable effect on the disease activity and function. Although not yet confirmed, the modulation of the microbiome with the help of probiotics or fecal transplant has face validity given the evolving scientific rationale. Diet has only limited role in the management of axSpA. Deep tissue massage, omega-3 fatty acids and Stanger bath were found to be useful in small studies. CAM therapies are not always entirely well tolerated, particularly the manipulative techniques like chiropractic and Tui-na in patients with advanced disease and osteoporosis. There are no trials of yoga in axSpA despite the wider acceptance and use of yoga as an effective mind-body technique. Larger and better quality clinical trials of CAM therapies are needed to confirm their efficacy and safety in the management of axSpA and to include them in the 'mainstream' medicine.

  3. Quantitative lateral and axial flow imaging with optical coherence microscopy and tomography.

    Science.gov (United States)

    Bouwens, Arno; Szlag, Daniel; Szkulmowski, Maciej; Bolmont, Tristan; Wojtkowski, Maciej; Lasser, Theo

    2013-07-29

    Optical coherence tomography (OCT) and optical coherence microscopy (OCM) allow the acquisition of quantitative three-dimensional axial flow by estimating the Doppler shift caused by moving scatterers. Measuring the velocity of red blood cells is currently the principal application of these methods. In many biological tissues, blood flow is often perpendicular to the optical axis, creating the need for a quantitative measurement of lateral flow. Previous work has shown that lateral flow can be measured from the Doppler bandwidth, albeit only for simplified optical systems. In this work, we present a generalized model to analyze the influence of relevant OCT/OCM system parameters such as light source spectrum, numerical aperture and beam geometry on the Doppler spectrum. Our analysis results in a general framework relating the mean and variance of the Doppler frequency to the axial and lateral flow velocity components. Based on this model, we present an optimized acquisition protocol and algorithm to reconstruct quantitative measurements of lateral and axial flow from the Doppler spectrum for any given OCT/OCM system. To validate this approach, Doppler spectrum analysis is employed to quantitatively measure flow in a capillary with both extended focus OCM and OCT.

  4. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  5. Axial resolution improvement by spectral data fusion in simultaneous dual-band optical coherence tomography

    Science.gov (United States)

    Cimalla, Peter; Gaertner, Maria; Walther, Julia; Koch, Edmund

    2011-06-01

    A method for axial resolution improvement by adequate spectral data fusion of two parallel acquired disjunct wavelength bands in the 0.8 μm and 1.3 μm region in the field of simultaneous dual-band optical coherence tomography (OCT) is presented. The applied spectral domain dual-band OCT system is illuminated by a supercontinuum laser light source and allows simultaneous imaging at 800 nm and 1250 nm with free-space axial resolutions better than 4.5 μm and 7 μm, respectively, over the entire depth scan range. Each wavelength band is analyzed with an individual spectrometer at an A-scan rate of 12 kHz. To further improve axial resolution, the 1250 nm spectra are fused with the 800 nm spectra considering the spectrometer-inherent non-linear fringe frequency course of the interference light. The phase and amplitude of the 1250 nm spectra are matched to the 800 nm spectra by means of short time Fourier transform analysis in order to obtain ideally continuous joint spectra. The joint spectra then undergo conventional spectral shaping, wave number resampling, windowing and fast Fourier transformation. First results for single A-scans of a glass slide as well as entire cross-sectional images of biological tissue yield an axial resolution improvement of 52 % compared to conventional single band imaging at 800 nm. The obtained A-scans show a good sharpness with a side lobe suppression of 30 dB. Additional investigations have to be employed for the full understanding of the underlying physical background and the optimization of the applied data processing for further image quality enhancement.

  6. X-ray detectors in axial computed tomography development; Sensori di radiazioni X negli sviluppi della tomografia assiale computerizzata

    Energy Technology Data Exchange (ETDEWEB)

    Gislon, R.; Imperiali, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione

    1996-12-01

    The increase of potentially of axial computed tomography as a non destructive investigation method in industrial field is particularly tied to the development of the X-rays detectors. The transition from the first gas ionization detectors to the last semiconductor detectors has indeed dramatically increased the performances of tomographic systems. In this report, after a quick analysis of fundamental principles of tomography, the most significant parameters for a detector to be used in a tomographic system are reviewed. The examination of the principal kinds of detectors that have been up to now used, with their working schemes, allows to delineate their characteristics and so to compare them with the ideal detector sketched above. The necessity of using high definition arrays brings to put into evidence the inadequacy of both gas and liquid ionization detectors and also of those types of light conversion devices which utilize for signal amplification a photomultiplier tube. Systems based on charge coupled devices or on a light conversion obtained with semiconductor photodiode arrays are definitely to be preferred. The progress of the last years in microelectronic technologies has brought great improvements in this field.

  7. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    International Nuclear Information System (INIS)

    Sondheimer, H.M.; Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-01-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease

  8. Value of the computerized axial tomography for early diagnosis of cranio cerebral trauma

    International Nuclear Information System (INIS)

    Rodriguez Cheong, Maricel; Dosouto Infante, Vivian; Rosales Fargie, Yamile

    2010-01-01

    A descriptive and cross-sectional study was conducted in 62 patients with cranio cerebral trauma admitted to 'Saturnino Lora' Provincial Teaching Hospital of Santiago de Cuba, from January 2005 to May 2006, in whom computerized axial tomography indicated at the emergency room was performed with the purpose of evaluating the effectiveness of this radiographic technique for early diagnosis of the injury. In the case material there was neither association between the source and imaging results, nor between the age and sex. The main clinical manifestations were vomiting, headache and motor deficit as well as frontal location, intraparenchymatous hematoma (the latter as the most common image finding) and the hyperdense area as tomographic pattern. The survival was of 91,9%

  9. Long axial imaging range using conventional swept source lasers in optical coherence tomography via re-circulation loops

    Science.gov (United States)

    Bradu, Adrian; Jackson, David A.; Podoleanu, Adrian

    2018-03-01

    Typically, swept source optical coherence tomography (SS-OCT) imaging instruments are capable of a longer axial range than their camera based (CB) counterpart. However, there are still various applications that would take advantage for an extended axial range. In this paper, we propose an interferometer configuration that can be used to extend the axial range of the OCT instruments equipped with conventional swept-source lasers up to a few cm. In this configuration, the two arms of the interferometer are equipped with adjustable optical path length rings. The use of semiconductor optical amplifiers in the two rings allows for compensating optical losses hence, multiple paths depth reflectivity profiles (Ascans) can be combined axially. In this way, extremely long overall axial ranges are possible. The use of the recirculation loops produces an effect equivalent to that of extending the coherence length of the swept source laser. Using this approach, the achievable axial imaging range in SS-OCT can reach values well beyond the limit imposed by the coherence length of the laser, to exceed in principle many centimeters. In the present work, we demonstrate axial ranges exceeding 4 cm using a commercial swept source laser and reaching 6 cm using an "in-house" swept source laser. When used in a conventional set-up alone, both these lasers can provide less than a few mm axial range.

  10. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  11. Excessive lateral patellar translation on axial computed tomography indicates positive patellar J sign.

    Science.gov (United States)

    Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua

    2018-03-20

    The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J sign was 70%. The BOI measured from the axial CT scans of the knee joint can be used as an appropriate predictor to differentiate the positive J sign from the negative J sign, highlighting that the excessive lateral patellar translation on axial CT scan indicates positive

  12. Imagenological characterization by Computerized Axial Tomography of the primary intracranial tumors

    International Nuclear Information System (INIS)

    Sosa Rivera, Manuel; Quintas Santana, Maria

    2009-01-01

    A descriptive observational study to 56 patients with imagenological diagnosis of primary intracranial neoplasia attended in the service of imagenology of the Provincial Docent Hospital 'Dr. Antonio Luaces Iraola' was carried out from March 1st 2006 to February 1st 2008, with the aim of characterizing these injuries by Computerized Axial Tomography and establishing an evaluation with the histological diagnosis. A questionnaire with the following variables was applied: sex, presuntive age, clinic, topographical characteristics (location, size, tumoral density, changes with administration of the resistance, calcifications, effect of mass and evaluation of the imagenological diagnosis with the histological diagnosis. Masculine sex and the group of ages of 60 are more predominated. The more frequent clinical manifestations were migraine, convulsions, difficulty to walk and vertigo. The size of the injury that prevailed was of 5, 9 and 2, 1 cm with supratentorial location. The majority of primary intracranial neoplasms were hypodense, and enhancement of the injuries with the administration of the resistance was observed. The mass effect bears a close relation with the location and size of the injury. The imagenological diagnosis fitted in with the histological one, being the gliomas the more frequent histological type

  13. Evaluation for computerized axial tomography to three anthropomorphic methods to estimate the thigh muscle area

    International Nuclear Information System (INIS)

    Fernandez Vieitez, Jorge Alberto; Alvarez Cuesta, Jose Alberto; Williams Wilson, Luis

    2001-01-01

    Three anthropometric methods to estimate the thigh muscle area (TMA, cm) were evaluated. Seventeen young males were taken as a sample. The TMA was estimated by using the formulas of Gurney-Jellife, Jones-Pearson, Housh, and others. In the same place where the measurements of circumferences and skinfolds were made, the TAM was determined by computerized axial tomography. It was used as a reference criterion with which the anthropometric values were compared. The methods of Gurney-Jellife and Jones-Pearson significantly overestimated the TAM obtained by CAT (9.0 + - 12.8 cm 2 [4.4 %]; p = 0.01 and 22.0 + - 14.9 cm 2 [10.9 %]; p = 1.6 . 10-5, respectively), whereas that of Housh and others underestimated the values of CAT (-48.8 + - 11.7 cm 2 [24.1 %]; p = 9.4 . 10-12). The Gurney-Jellife equation was the only one that proved to be interchangeable with CAT, on obtaining a coefficient of correlation (r) and a slope of regression (b) for the difference and the average between both methods that were not statistically significant (r 0,421; b = 0,21 + - 0.12, p = 0.09). It was concluded that of the 3 studied anthropometric methods, the Gurney-Jellife method offers the most accurate TAM values

  14. High-resolution 3-D imaging of living cells in suspension using confocal axial tomography.

    Science.gov (United States)

    Renaud, Olivier; Viña, Jose; Yu, Yong; Machu, Christophe; Trouvé, Alain; Van der Voort, Hans; Chalmond, Bernard; Shorte, Spencer L

    2008-01-01

    Conventional flow cytometry (FC) methods report optical signals integrated from individual cells at throughput rates as high as thousands of cells per second. This is further combined with the powerful utility to subsequently sort and/or recover the cells of interest. However, these methods cannot extract spatial information. This limitation has prompted efforts by some commercial manufacturers to produce state-of-the-art commercial flow cytometry systems allowing fluorescence images to be recorded by an imaging detector. Nonetheless, there remains an immediate and growing need for technologies facilitating spatial analysis of fluorescent signals from cells maintained in flow suspension. Here, we report a novel methodological approach to this problem that combines micro-fluidic flow, and microelectrode dielectric-field control to manipulate, immobilize and image individual cells in suspension. The method also offers unique possibilities for imaging studies on cells in suspension. In particular, we report the system's immediate utility for confocal "axial tomography" using micro-rotation imaging and show that it greatly enhances 3-D optical resolution compared with conventional light reconstruction (deconvolution) image data treatment. That the method we present here is relatively rapid and lends itself to full automation suggests its eventual utility for 3-D imaging cytometry.

  15. [Correlation between diagnostic hypothesis and result of cranial computed axial tomography].

    Science.gov (United States)

    Nóvak, E M; Terabe, F; Nasimoto, A L; Carvalho, P H; Loper, A D; Büchele, F S; Nogara, J C

    2001-09-01

    The use of computed axial tomography (CT) in the investigation of neurologic disorders is attractive for its disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 +/- 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36.2%), Emergency room (17.4%), Pediatric Neurology (16.9%) and Internal Medicine (5.9%). The CT was more indicated in cases of seizures (30%), headache (26.2%), motor impairment (20.2%) and reduction of conscience level (16.9%). The main hypothetic diagnosis were "to discard anatomic lesions" (9.0%), not specified stroke (8.2%) and neurocisticercosis (8.2%). The result of the CT was normal in 50.4% of the exams specially those requested in cases of headache (94.4%), seizures (71.4%) and "to discard anatomic lesions"(66.7%). The more frequently CT abnormalities were hydrocephalus (5.4%), ischemic stroke (5.4%) and neoplasm (3.5%) The greatest rates of correlation were among those to discard anatomic lesions (66,7%), hydrocephalus (50%), ischemic stroke (50%) and hematoma (50%). We concluded that CT is more helpful if more clinical data is provided in the request form, so aiding the radiologist in the final report.

  16. Complementary role of computerized axial transmission tomography and radionuclide imaging of the brain

    International Nuclear Information System (INIS)

    Fordham, E.W.

    1977-01-01

    Computerized axial transmission tomography and radionuclide imaging are complementary procedures, and the following recommendations are made as to their use. Where there is no real clinical suspicion of intracranial disease, either modality can be used for ''rule out'' screening; the choice can frequently be made on the basis of which modality is cheaper or more quickly available. It should be remembered that ''quicker'' is often ''cheaper.'' Total cost is determined, not only by the cost of the procedure, but also the per diem costs incurred in waiting for that procedure. Thus the more expensive modality may, in effect, be cheaper if delays are shorter. Screening of the elderly patient, particularly when atrophy or communicating hydrocephalus is of clinical concern, should be by the CT method because of its ability to visualize cerebrospinal fluid spaces. When clinical signs and symptoms point to intracranial abnormality, both modalities should be utilized. If either study done first is normal, use of the other modality is mandatory. When the first study is positive with pathognomonic findings for a specific disease, which totally explains the patient's neurologic problems, the second study need not be employed. Such examples might include the fresh cerebral hemorrhage demonstrated by CT imaging, the AV malformation defined by dynamic-static radionuclide imaging, or multifocal metastatic lesions defined by either. However, when the clinical picture is not totally and satisfactorily explained by the demonstrated disease, the other modality should also be employed. Under many circumstances, neither study will be so reliable, specific, and free of false-negative or false-positive findings as to warrant ignoring the additional information potentially available from the other study

  17. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  18. Density measurements with computed tomography in patients with extra-axial hematoma can quantitatively estimate a degree of brain compression.

    Science.gov (United States)

    Nguyen, Ha Son; Li, Luyuan; Patel, Mohit; Mueller, Wade

    2016-10-01

    Extra-axial hematoma can cause significant brain compression. Guidelines for surgical evacuation include imaging findings (midline shift and hematoma thickness/volume) in conjunction with Glasgow Coma Scale (GCS) scores and/or intracranial pressure (ICP) monitoring. Physiologically, overall brain density should also change with compression. In our observational study, we explored whether overall brain density, defined using computed tomography Hounsfield Units (CT HU), changes after surgical evacuation of extra-axial hematoma. Only patients with a surgical acute epidural hematoma or subacute/chronic subdural hematoma were considered. Other exclusion criteria were concurrent intraparenchymal pathology, bilateral pathology, or incomplete follow-up imaging. Between fall 2012 and spring 2015, 22 patients were included in the study. CT head imaging (preoperative, postoperative, and at ∼1- to 2-month clinic visit) were loaded into OsiriX (Pixmeo, Switzerland). All the intracranial regions were selected and all extra-axial features were removed; subsequently, software was used to calculate a global CT HU value. A repeated-measures ANOVA found significant time effect, p brain, can cause an elevation in global CT HU value; moreover, surgical decompression is associated with lower global CT HU values. The use of global CT HU values in selected populations may serve as an adjunct for the evaluation of surgical lesions. © The Author(s) 2016.

  19. Axial resolution and the value of interpolating scan in multislice positron computed tomography.

    Science.gov (United States)

    Senda, M; Yonekura, Y; Tamaki, N; Tanaka, Y; Komori, M; Minato, K; Konishi, J; Torizuka, K

    1985-01-01

    We have calculated the aperture function of a positron computed tomograph (PCT) with computer simulation, and evaluated the axial resolution of a multislice PCT, Positologica III, both theoretically and experimentally. The axial point spread function (PSF) was approximately a triangle at or near the center of the field, and the sensitivity for the slice decreased significantly as the source moved away off the image plane. Accordingly, there were low sensitivity areas between an in-plane and the adjacent cross-plane. This invisible region was clinically significant if the object was thin enough in the z-axis. In order to fill up the gaps between adjacent slices, it is valuable to move the patient half the slice interval in the z-axis and perform an " interpolating scan."

  20. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sondheimer, H.M. (Upstate Medical Center, Syracuse, NY); Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-05-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease.

  1. Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, Nathalia Cristine; Junqueira, Jose Luiz Cinta; Panzarella, Francine Keuhi; Raitz, Ricardo [Sao Leopoldo Mandic Research Center, Dept. of Oral Radiology, College of Dentistry, Sao Paulo (Brazil); Brriviera, Mauricio [Dept. of Oral Radiology, College of Dentistry, Catholic University of Brasilia, Sao Paulo (Brazil)

    2017-03-15

    This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

  2. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Sampson, Danuta M; Gong, Peijun; An, Di; Menghini, Moreno; Hansen, Alex; Mackey, David A; Sampson, David D; Chen, Fred K

    2017-06-01

    To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA). Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae. Relative changes between corrected and uncorrected SRVD and FAZA were calculated. Forty subjects were enrolled and the median (range) age of the participants was 30 (18-74) years. The mean (range) spherical equivalent refractive error was -1.65 (-8.00 to +4.88) diopters and mean (range) axial length was 24.42 mm (21.27-28.85). Images from 13 eyes were excluded due to poor image quality leaving 67 for analysis. Relative changes in foveal and parafoveal SRVD and FAZA after correction ranged from -20% to +10%, -3% to +2%, and -20% to +51%, respectively. Image size correction in measurements of foveal SRVD and FAZA was greater than 5% in 51% and 74% of eyes, respectively. In contrast, 100% of eyes had less than 5% correction in measurements of parafoveal SRVD. Ocular biometry should be performed with OCTA to correct image magnification error induced by axial length variation. We advise caution when interpreting interocular and interindividual comparisons of SRVD and FAZA derived from OCTA without image size correction.

  3. Axial myopathy

    DEFF Research Database (Denmark)

    Witting, Nanna; Andersen, Linda K; Vissing, John

    2016-01-01

    Classically, myopathies are categorized according to limb or cranial nerve muscle affection, but with the growing use of magnetic resonance imaging it has become evident that many well-known myopathies have significant involvement of the axial musculature. New disease entities with selective axial...

  4. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator.

    Science.gov (United States)

    Andersson, P; Andersson-Sunden, E; Sjöstrand, H; Jacobsson-Svärd, S

    2014-08-01

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm(-1), solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful

  5. Utility of computed axial tomography angiography in anatomic evaluation of pediatric patients with congenital heart diseases

    International Nuclear Information System (INIS)

    Mosquera, Walter A; Reyes P, Rafael; Aguilera N, Favio M; Breton, Cesar A; Buitrago, Danuby A; Suarez J Ramiro; Castillo, Victor

    2007-01-01

    Although echocardiogram and cardiac catheterization are used as first option tools for congenital heart diseases diagnosis, computed tomography angiography is a minimally invasive exam that through two to three dimensional images in real time gives an adequate approach to patients having this type of pathologies that require a rapid and precise evaluation of its extra cardiac anatomy. Objective: describe the institutional experience from August 2005 to August 2006 in the use of angiography by tomography as a complementary diagnostic method in the evaluation of pediatric patients with congenital heart diseases. Method: serial descriptive study. 58 pediatric patients with clinical and echocardiographic diagnosis of congenital heart diseases were evaluated through the General Electric Multislice Light peed/16 scanner. Results: 58 patients with history of congenital heart disease were evaluated through CT angiography. Mean age was 2.4 ± 4.03 years. Twenty (33.8%) had diagnosis of pulmonary atresia, four (6.7%) had tricuspid atresia, eight (13.5%,) had double-outlet right ventricle, seven (11.8%) had tetralogy of Fallot, nine (15.2%) had alterations of the aortic arch, seven (11.8%) had coarctation of the aorta two (3.3%) had interrupted aortic arch, six (10.3%) had persistent ductus arteriosus, four (6.7%) had anomalous venous drainage and three (5.1 %) had transposition of the great arteries. High quality images that allowed assessing the precise vascular anatomy were obtained. Conclusions: computed tomography angiography turned out to be a useful tool in the diagnostic approach of congenital heart diseases, because it allowed a tridimensional anatomic reconstruction. New studies that may permit the assessment of sensitivity, specificity and concordance level of this technique with other invasive diagnostic methods available for the diagnosis of this type of diseases, are required

  6. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane.

    Science.gov (United States)

    Kim, Ji-Beom; Yi, Young; Kim, Jae-Young; Cho, Jae-Ho; Kwon, Min-Soo; Choi, Seung-Hyuk; Lee, Woo-Chun

    2017-08-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis.

  7. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun [Seoul Foot and Ankle Center, Dubalo Orthopaedic Clinic, Seochogu, Seoul (Korea, Republic of); Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk [Inje University Seoul Paik Hospital, Department of Orthopaedic Surgery, Jung-gu, Seoul (Korea, Republic of); Cho, Jae-Ho [Hallym University, ChunCheon Sacred Heart Hospital, Department of Orthopaedic Surgery, Chuncheon, GangWon-do (Korea, Republic of)

    2017-08-15

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  8. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    International Nuclear Information System (INIS)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun; Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk; Cho, Jae-Ho

    2017-01-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  9. A method for volume determination of the orbit and its contents by high resolution axial tomography and quantitative digital image analysis.

    Science.gov (United States)

    Cooper, W C

    1985-01-01

    The various congenital and acquired conditions which alter orbital volume are reviewed. Previous investigative work to determine orbital capacity is summarized. Since these studies were confined to postmortem evaluations, the need for a technique to measure orbital volume in the living state is presented. A method for volume determination of the orbit and its contents by high-resolution axial tomography and quantitative digital image analysis is reported. This procedure has proven to be accurate (the discrepancy between direct and computed measurements ranged from 0.2% to 4%) and reproducible (greater than 98%). The application of this method to representative clinical problems is presented and discussed. The establishment of a diagnostic system versatile enough to expand the usefulness of computerized axial tomography and polytomography should add a new dimension to ophthalmic investigation and treatment.

  10. Evolution of the dinosauriform respiratory apparatus: new evidence from the postcranial axial skeleton.

    Science.gov (United States)

    Schachner, Emma R; Farmer, C G; McDonald, Andrew T; Dodson, Peter

    2011-09-01

    Examination of the thoracic rib and vertebral anatomy of extant archosaurs indicates a relationship between the postcranial axial skeleton and pulmonary anatomy. Lung ventilation in extant crocodilians is primarily achieved with a hepatic piston pump and costal rotation. The tubercula and capitula of the ribs lie on the horizontal plane, forming a smooth thoracic "ceiling" facilitating movement of the viscera. Although the parietal pleura is anchored to the dorsal thoracic wall, the dorsal visceral pleura exhibits a greater freedom of movement. The air sac system and lungs of birds are associated with bicapitate ribs with a ventrally positioned capitular articulation, generating a rigid and furrowed rib cage that minimizes dorsoventral changes in volume in the dorsal thorax. The thin walled bronchi are kept from collapsing by fusion of the lung to the thorax on all sides. Data from this study suggest a progression from a dorsally rigid, heterogeneously partitioned, multichambered lung in basal dinosauriform archosaurs towards the small entirely rigid avian-style lung that was likely present in saurischian dinosaurs, consistent with a constant volume cavum pulmonale, thin walled parabronchi, and distinct air sacs. There is no vertebral evidence for a crocodilian hepatic piston pump in any of the taxa reviewed. The evidence for both a rigid lung and unidirectional airflow in dinosauriformes raises the possibility that these animals had a highly efficient lung relative to other Mesozoic vertebrates, which may have contributed to their successful radiation during this time period. Copyright © 2011 Wiley-Liss, Inc.

  11. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    Directory of Open Access Journals (Sweden)

    Akinobu Watanabe

    Full Text Available Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT imaging. Complementary examination of external and internal osteology reveals (1 highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2 anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3 apneumatic sacral vertebrae; and (4 a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  12. Ultrastructural evidence of the excretory function in the asteroid axial organ (Asteroidea, Echinodermata).

    Science.gov (United States)

    Ezhova, O V; Egorova, E A; Malakhov, V V

    2016-05-01

    The ultrastructure of the axial organ of Asterias amurensis has been studied The organ is a network of canals of the axial coelom separated by haemocoelic spaces. The axial coelom is lined with two types of monociliary cells: podocytes and musculo-epithelial cells. Podocytes form numerous basal processes adjacent to the basal lamina on the coelomic side. Musculo-epithelial cells form processes running along the basal lamina. Some bundles of these processes wrapped in the basal lamina pass through haemocoelic spaces between neighboring coelomic canals. It is hypothesized that the axial organ serves for filtration of fluid from haemocoelic spaces into the axial coelom cavity, from which urine is excreted through the madreporite to the exterior.

  13. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    a".turjore posterior. lateral. ante r ior TABLE 3 Dose values from diffused radiation Occhi - eyets Tiroide - thyroid Gonadi -gonads Soggetti...Dose do~vuta a&radiatiode-. diffusa j Ochij Tiroide " GZd 5]g&*tl Riferimen: EMIlscanner CTIOIO 0.850 0.310 0.030 bambini (36) di 10 Kg Angiografia

  14. Are Hox genes ancestrally involved in axial patterning? Evidence from the hydrozoan Clytia hemisphaerica (Cnidaria.

    Directory of Open Access Journals (Sweden)

    Roxane Chiori

    Full Text Available BACKGROUND: The early evolution and diversification of Hox-related genes in eumetazoans has been the subject of conflicting hypotheses concerning the evolutionary conservation of their role in axial patterning and the pre-bilaterian origin of the Hox and ParaHox clusters. The diversification of Hox/ParaHox genes clearly predates the origin of bilaterians. However, the existence of a "Hox code" predating the cnidarian-bilaterian ancestor and supporting the deep homology of axes is more controversial. This assumption was mainly based on the interpretation of Hox expression data from the sea anemone, but growing evidence from other cnidarian taxa puts into question this hypothesis. METHODOLOGY/PRINCIPAL FINDINGS: Hox, ParaHox and Hox-related genes have been investigated here by phylogenetic analysis and in situ hybridisation in Clytia hemisphaerica, an hydrozoan species with medusa and polyp stages alternating in the life cycle. Our phylogenetic analyses do not support an origin of ParaHox and Hox genes by duplication of an ancestral ProtoHox cluster, and reveal a diversification of the cnidarian HOX9-14 genes into three groups called A, B, C. Among the 7 examined genes, only those belonging to the HOX9-14 and the CDX groups exhibit a restricted expression along the oral-aboral axis during development and in the planula larva, while the others are expressed in very specialised areas at the medusa stage. CONCLUSIONS/SIGNIFICANCE: Cross species comparison reveals a strong variability of gene expression along the oral-aboral axis and during the life cycle among cnidarian lineages. The most parsimonious interpretation is that the Hox code, collinearity and conservative role along the antero-posterior axis are bilaterian innovations.

  15. Mandibular condylar fractures and acute atlanto-axial subluxation. Part 1 - A new clinical and nosographic evidence.

    Science.gov (United States)

    Cutilli, T; Corbacelli, A

    2009-05-01

    The aim of this study was to analyze the acute repercussions of condylar mandibular fractures on occipital-atlanto-axial joint. Twenty-five non-consecutive cases (16 males and 9 females, mean age: 22.96/range 14-36 years), observed and treated in the Maxillofacial Surgery Department of the University of L'Aquila have been considered. Types of fractures examined included: unilateral: 19 cases (solitary: 12; associated with other mandibular fractures: 7; homolateral: 2); bilateral: 6 cases (equivalent: 2; not equivalent: 4). A control group was constituted of 10 patients, 5 males and 5 females, aged from 19 to 24 years (mean-range: 21.6) suffering from acute isolated cervical distorsion (whiplash). The study has been performed by means of the analysis of X-ray and computed tomography (CT)-CT/3D of the mandibular condylar regions, the occipital-atlanto-axial structures and the cervical region. In all the cases of fractures of the mandibular condyle an acute alteration of the junctional atlanto-axial structures was present. In case of unilateral solitary condylar fractures the authors have observed an atlas rotation, homolateral to the side of the condylar fracture, independent from the level of the fracture (intra- or extracapsular). The rotation seems to be proportional to the entity of the condylar fragments dislocation on the horizontal plane and it causes a modification of the articular relations between atlas and axis (atlanto-axial subluxation) and between the atlas and the occipital bone. The authors have observed a constant derangement of the cranio-axial joint on the three planes of the space. In particular, on the vertical plane the CT reconstructions show on the right and left side a different height between the atlanto-axial articular spaces. The largest one is homolateral to the side of the condylar fracture. In case of unilateral condylar fractures associated with other mandibular fracture (homolateral or not) the authors have observed the same

  16. Limitaciones de la tomografia axial computada en la localizacion de quistes hidatidicos abdominales en pacientes con confirmacion inmunodiagnostica Limitations of computerized axial tomography in the localization of abdominal hydatid cysts in patients with immunodiagnostic confirmation

    Directory of Open Access Journals (Sweden)

    E. A. Guarnera

    1984-12-01

    Full Text Available Se describe el aporte de la prueba de doble disfusión arco 5 (DD5 al diagnóstico de la hidatidosis en dos pacientes con operaciones previas. En una de ellas, asintomática, la reacción positiva a los cinco años de su última intervención quirúrgica por hidatidosis, permitió diagnosticar la presencia de quistes cuya localización abdominal fue establecida por la tomografía axial computada (TAC. En el otro caso, sintomático, aunque operado de hidatidosis nueve años antes, la positividad a la DD5 confirmó la etiología de la enfermedad que se había sospechado por centellografía, TAC y su historia clínica. En ambos casos, sin embargo, se hallaron en el acto quirúrgico otros quistes abdominales cuyas imágenes no habían sido reveladas en los estudios a los que se las había sometido.The contribution of the arc 5 double diffusion test (DD5 to the diagnosis of hydatidosis in two patients with previous surgery for this parasitic infection is described. In one of the patients, who was asymptomatic, the diagnosis was established on the basis of a positive DD5 reaction five years after her last surgical intervention. The abdominal location of cysts was revealed by computerized axial tomography (CAT. The other patient had been operated on for hydatidosis nine years earlier and showed symptoms. Positivity to the DD5 test confirmed the etiology of the disease, which had been suspected on the basis of her clinical history and the findings of scintillographic and CAT studies. In both cases, however, other abdominal cysts were found at surgery whose images had not been revealed in the previous studies.

  17. Comparison of 3D cellular imaging techniques based on scanned electron probes: Serial block face SEM vs. Axial bright-field STEM tomography.

    Science.gov (United States)

    McBride, E L; Rao, A; Zhang, G; Hoyne, J D; Calco, G N; Kuo, B C; He, Q; Prince, A A; Pokrovskaya, I D; Storrie, B; Sousa, A A; Aronova, M A; Leapman, R D

    2018-02-01

    Microscopies based on focused electron probes allow the cell biologist to image the 3D ultrastructure of eukaryotic cells and tissues extending over large volumes, thus providing new insight into the relationship between cellular architecture and function of organelles. Here we compare two such techniques: electron tomography in conjunction with axial bright-field scanning transmission electron microscopy (BF-STEM), and serial block face scanning electron microscopy (SBF-SEM). The advantages and limitations of each technique are illustrated by their application to determining the 3D ultrastructure of human blood platelets, by considering specimen geometry, specimen preparation, beam damage and image processing methods. Many features of the complex membranes composing the platelet organelles can be determined from both approaches, although STEM tomography offers a higher ∼3 nm isotropic pixel size, compared with ∼5 nm for SBF-SEM in the plane of the block face and ∼30 nm in the perpendicular direction. In this regard, we demonstrate that STEM tomography is advantageous for visualizing the platelet canalicular system, which consists of an interconnected network of narrow (∼50-100 nm) membranous cisternae. In contrast, SBF-SEM enables visualization of complete platelets, each of which extends ∼2 µm in minimum dimension, whereas BF-STEM tomography can typically only visualize approximately half of the platelet volume due to a rapid non-linear loss of signal in specimens of thickness greater than ∼1.5 µm. We also show that the limitations of each approach can be ameliorated by combining 3D and 2D measurements using a stereological approach. Copyright © 2018. Published by Elsevier Inc.

  18. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  19. Pathological investigation of caries and occlusal pulpar exposure in donkey cheek teeth using computerised axial tomography with histological and ultrastructural examinations.

    Science.gov (United States)

    Toit, Nicole du; Burden, Faith A; Kempson, Sue A; Dixon, Padraic M

    2008-12-01

    Post-mortem examination of 16 donkey cheek teeth (CT) with caries (both peripheral and infundibular) and pulpar exposure were performed using computerised axial tomography (CAT), histology and scanning electron microscopy. CAT imaging was found to be useful to assess the presence and extent of caries and pulp exposure in individual donkey CT. Histology identified the loss of occlusal secondary dentine, and showed pulp necrosis in teeth with pulpar exposure. Viable pulp was present more apically in one exposed pulp horn, with its occlusal aspect sealed off from the exposed aspect of the pulp horn by a false pulp stone. Scanning electron microscopy showed the amelo-cemental junction to be a possible route of bacterial infection in infundibular cemental caries. The basic pathogenesis of dental caries in donkeys appears very similar to its description in other species.

  20. Fourier domain mode locking at 1050 nm for ultra-high-speed optical coherence tomography of the human retina at 236,000 axial scans per second.

    Science.gov (United States)

    Huber, R; Adler, D C; Srinivasan, V J; Fujimoto, J G

    2007-07-15

    A Fourier domain mode-locked (FDML) laser at 1050 nm for ultra-high-speed optical coherence tomography (OCT) imaging of the human retina is demonstrated. Achievable performance, physical limitations, design rules, and scaling principles for FDML operation and component choice in this wavelength range are discussed. The fiber-based FDML laser operates at a sweep rate of 236 kHz over a 63 nm tuning range, with 7 mW average output power. Ultra-high-speed retinal imaging is demonstrated at 236,000 axial scans per second. This represents a speed improvement of approximately10x over typical high-speed OCT systems, paving the way for densely sampled volumetric data sets and new imaging protocols.

  1. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nizic, Dinko [Zagreb University Hospital Center, Clinical Institute of Diagnostic and Interventional Radiology, Zagreb (Croatia)

    2012-09-15

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  2. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  3. Application of the axial tomography computed for the detection of bags of dampness in dry wood of Gmelina arborea (Roxb.)

    International Nuclear Information System (INIS)

    Moya R, Roger; Munoz A, Freddy; Escalante, Ivan

    2006-01-01

    Gmelina arborea (Roxb.) is widely used for commercial reforestation in Costa Rica due to its excellent growth rate and productivity. However, during the lumber drying process, the wooden boards show non-uniform values of final moisture content (MC). The low uniformity in final MC is caused by the presence of wet pockets, originated during the growing process of the tree. The regions with wet pockets present zones with a high MC, which are hard to detect with traditional methods for MC measurements during the wood drying process. It is possible to detect and to set the limits of the presence of wet wood in Gmelina arborea boards using scanning computed tomography (CT-scanning), a technique applied in medical diagnostic. A board with wet pockets is shown in the CT-scanning images in clear color and with low values of the Hounsfield Unit (HU) or CT number. When these values were transformed to wood density, it was determined that wet pockets were in a density of around 190 kg/m 3 , a value higher than normal wood. Also, it was possible to observe growth tree rings in the CT-scanning images, an important feature for dendrochronological research. The obtained results allowed showing that it is possible to apply this technique in the process of lumber production, to detect the zones with high MC in kiln dried Gmelina arborea wood. (author) [es

  4. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  5. Real-time axial motion detection and correction for single photon emission computed tomography using a linear prediction filter

    International Nuclear Information System (INIS)

    Saba, V.; Setayeshi, S.; Ghannadi-Maragheh, M.

    2011-01-01

    We have developed an algorithm for real-time detection and complete correction of the patient motion effects during single photon emission computed tomography. The algorithm is based on a linear prediction filter (LPC). The new prediction of projection data algorithm (PPDA) detects most motions-such as those of the head, legs, and hands-using comparison of the predicted and measured frame data. When the data acquisition for a specific frame is completed, the accuracy of the acquired data is evaluated by the PPDA. If patient motion is detected, the scanning procedure is stopped. After the patient rests in his or her true position, data acquisition is repeated only for the corrupted frame and the scanning procedure is continued. Various experimental data were used to validate the motion detection algorithm; on the whole, the proposed method was tested with approximately 100 test cases. The PPDA shows promising results. Using the PPDA enables us to prevent the scanner from collecting disturbed data during the scan and replaces them with motion-free data by real-time rescanning for the corrupted frames. As a result, the effects of patient motion is corrected in real time. (author)

  6. Correlação entre hipótese diagnóstica e laudo de tomografia axial computadorizada craniana Correlation between diagnostic hypothesis and result of cranial computed axial tomography

    Directory of Open Access Journals (Sweden)

    Edison Matos Nóvak

    2001-09-01

    Full Text Available Para avaliar a utilização da tomografia axial computadorizada craniana (TC em nosso meio, analisamos as solicitações de 367 exames consecutivos no período compreendido entre 07/1995 e 07/1996. Houve ampla variação da faixa etária, com média de 31,7 ± 22,9 anos. As especialidades que mais solicitaram o exame foram: Neurologia (36,2%, Pronto Atendimento (17,4%, Neuropediatria (16,9% e Clínica Médica (5,9%. As indicações mais frequentes para o exame foram: convulsão (30%, cefaléia (26,2%, déficit motor (20,2% e redução do nível de consciência (16,9%. As "hipóteses" aventadas com maior frequência foram: afastar lesão estrutural (9,0%, acidente vascular não discriminado (8,2% e neurocisticercose (8,2%. O laudo da TC foi normal em 50,4% dos exames. Os laudos anormais mais frequentes foram: hidrocefalia (5,4%, acidente vascular isquêmico (5,4% e neoplasia (3,5%. As maiores taxas de achados normais foram encontradas nas "hipóteses" de cefaléia (94,4%, convulsão (71,4% e afastar lesão estrutural (66,7%. Os maiores índices de acerto entre hipótese e laudo foram encontrados nas situações de "afastar lesões estruturais" (66,7%, hidrocefalia (50%, acidente vascular cerebral isquêmico (50% e hematoma (50%. Concluimos que a utilização de um recurso auxiliar de diagnóstico como a TC cumpre melhor ainda a sua função se o requisitante do exame preencher com clareza e detalhamento o pedido do exame.The use of computed axial tomography (CT in the investigation of neurologic disorders is attractive for his disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 ± 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36

  7. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E. (National Institute of Aging, Baltimore, MD (USA))

    1990-11-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas.

  8. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    International Nuclear Information System (INIS)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E.

    1990-01-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas

  9. Study of the relationship and importance of clinical semiology, axial computed tomography and electroneuromyography in lumbar radioculopathies Estudo da relação e da importância entre a semiologia clínica, tomografia axial computadorizada e eletroneuromiografia nas radiculopatias lombares

    Directory of Open Access Journals (Sweden)

    Emílio Cezar Mamede Murade

    2002-12-01

    Full Text Available The authors evaluated forty-three patients with clinical suspect of lumbar radiculopathy caused by disk hernia, concerning to clinical semiology, computed tomography and electromyography were studied and their correlations. The clinical semiology was altered in 100,0% of the patients, the computed tomography in 90,7% and the electromyography in 88,7%. The correlation among the three exams didn´t show any prevalency among any of the possible associations. The authors emphasize the importance of clinical semiology, computed tomography and electromyography for a more accurate diagnosis of lumbar radiculopathy following by disk hernia.Os autores estudaram 43 pacientes com suspeita clínica de radiculopatia lombar, causada por hérnia de disco, relacionando os achados da semiologia clínica, tomografia axial computadorizada e eletroneuromiografia, entre si. A semiologia clínica estava alterada em 100,0% dos pacientes, a tomografia axial computadorizada em 90,7% e a eletroneuromiografia em 88,7%. A correlação entre os três exames não mostrou prevalência entre nenhuma associação. Os autores enfatizam a importância da semiologia clínica, tomografia axial computadorizada e eletroneuromiografia para maior exatidão diagnóstica das radiculopatias lombares por hérnia de disco.

  10. Tomography system having axial scanning

    International Nuclear Information System (INIS)

    1976-01-01

    An improved method and apparatus has been invented for the transaxial tomographic scanning of a patient to determine mass distribution internal to the patient. A scanning system is provided having a rotatably mounted X-ray radiation source/detector assembly which orbits and scans the patient in plane of orbit. The source provides a plurality of beams of radiation in the orbital plane. Beams pass through the patient to an array of detectors which are spaced in the plane of orbit and respectively aligned with one of the beams. Radiation intensity data is collected at predetermined orientations of each beam-detector pair as the assembly orbits about the patient

  11. Axial spondyloarthritis.

    Science.gov (United States)

    Sieper, Joachim; Braun, Jürgen; Dougados, Maxime; Baeten, Dominique

    2015-07-09

    The term axial spondyloarthritis covers both non-radiographic disease and radiographic disease (also known as ankylosing spondylitis). Some studies have been performed to investigate the prevalence of axial spondyloarthritis, although most are limited to patients with radiographic disease. A strong genetic association has been shown between axial spondyloarthritis and human leukocyte antigen-B27 (HLA-B27), but the pathogenetic role of HLA-B27 has not yet been clarified. Tumour necrosis factor (TNF), IL-17, IL-23 and downstream pathways also seem to be important - based on the good results of therapies directed against these molecules - but their exact role in the inflammatory process is also not yet clear. Elucidating the interaction between osteoproliferation and inflammation will be crucial for the prevention of long-term structural damage of the bone. The development of new criteria for classification, diagnosis and screening of patients with axial spondyloarthritis will enable earlier intervention for this chronic inflammatory disease. MRI has become an important tool for the early detection of axial spondyloarthritis. NSAIDs and TNF blockers are effective therapies, including in the early non-radiographic stage. Therapeutic blockade of IL-17 or IL-23 seems to be a promising new treatment option. Tools for measuring quality of life in axial spondyloarthritis have become relevant to assess the impact that the disease has on patients. These diagnostic and therapeutic advances will continue to change the management of axial spondyloarthritis, and new insights into the disease pathogenesis will hopefully accelerate this process. For an illustrated summary of this Primer, visit: http://go.nature.com/51b1af.

  12. Tomography

    International Nuclear Information System (INIS)

    Allan, C.J.; Keller, N.A.; Lupton, L.R.; Taylor, T.; Tonner, P.D.

    1984-10-01

    Tomography is a non-intrusive imaging technique being developed at CRNL as an industrial tool for generating quantitative cross-sectional density maps of objects. Of most interest is tomography's ability to: distinguish features within complex geometries where other NDT techniques fail because of the complexity of the geometry; detect/locate small density changes/defects within objects, e.g. void fraction measurements within thick-walled vessels, shrink cavities in castings, etc.; provide quantitative data that can be used in analyses, e.g. of complex processes, or fracture mechanics; and provide objective quantitative data that can be used for (computer-based) quality assurance decisions, thereby reducing and in some cases eliminating the present subjectivity often encountered in NDT. The CRNL program is reviewed and examples are presented to illustrate the potential and the limitations of the technology

  13. Computed Tomography

    Science.gov (United States)

    Castellano, Isabel; Geleijns, Jacob

    After its clinical introduction in 1973, computed tomography developed from an x-ray modality for axial imaging in neuroradiology into a versatile three dimensional imaging modality for a wide range of applications in for example oncology, vascular radiology, cardiology, traumatology and even in interventional radiology. Computed tomography is applied for diagnosis, follow-up studies and screening of healthy subpopulations with specific risk factors. This chapter provides a general introduction in computed tomography, covering a short history of computed tomography, technology, image quality, dosimetry, room shielding, quality control and quality criteria.

  14. Ultrastructure and potential sub-seafloor evidence of bacteriogenic iron oxides from Axial Volcano, Juan de Fuca Ridge, north-east Pacific Ocean.

    Science.gov (United States)

    Kennedy, C B; Scott, S D; Ferris, F G

    2003-03-01

    Iron oxides from the caldera of Axial Volcano, a site of hydrothermal vent activity along the Juan de Fuca Ridge, were found to consist predominantly of microbial structures in hydrated whole mounts examined using an environmental scanning electron microscope. Novel observations were made of the iron oxides revealing the spatial relationships of the bacteria within to be more consistent with microbial mats than mineral precipitates. The bacterial structures are attributed to the sheaths of Leptothrix ochracea, the stalks of Gallionella ferruginea, and the filaments of a novel iron oxidizing PV-1 strain, based on the distinctive morphological characteristics of these three bacteria. Energy dispersive X-ray spectroscopy revealed the presence and distribution of Fe, Si, and Cl on the bacterial sheaths, stalks and filaments. The iron oxides were identified by X-ray diffraction to be two-line ferrihydrite, a poorly ordered iron oxyhydroxide. Adsorption of Si in particular to two-line ferrihydrite likely contributes to its stability on the seafloor, and might also be a preservation mechanism creating microfossils of the bacterial structures encrusted with ferrihydrite. Presumptive evidence of the sub-seafloor presence of L. ochracea, G. ferruginea and PV-1 at Axial Volcano was obtained from the presence of these bacteria on a trap that had been placed within an active vent, and also in a vent fluid sample. If indeed these bacteria are present in the sub-seafloor, it may be an indication that the surface expression of iron oxide deposits at Axial Volcano is minimal in comparison to what exists beneath the seafloor.

  15. Prognosis of the computerized tomography in the severe head injury. Valor pronostico de la tomografia axial computada (TC) en los traumatismos craneoencefalicos severos

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Nieto, J.J.; Lorenzo Dominguez, M.T.; Martin Sanchez, M.J.; Sanchez Gonzalez, E.

    1991-01-01

    A prospective study is made with sixty five people affected of severe head injury, that is to say, with eight or less points in the Glasgow Coma Scale (GCS), when they get to the hospital. They are studied by computerized tomography at admission, and three and seven days after arrival. In this way, we appraise the type of the lesion, its intensity and the possible prognosis, considering in the last case three features: a) ventricular collapse; b) the mean line structure s shift; and c) effects on perimesencephalic cistern. The findings were parametized and we were able to introduce into the computer program relationships between these findings and the end results. These last ones were appraised through the Glasgow Outcome Scale (GOS). We could show that certain findings in computerized tomography scans have an unavoidable prognosis while as others have a more favorable prognosis. (Author)

  16. Evidence for a caudate role in aphasia from FDG positron emission tomography

    International Nuclear Information System (INIS)

    Metter, E.J.; Riege, W.H.; Hanson, W.R.; Phelps, M.; Kuhl, D.E.

    1982-01-01

    In a recent study correlations between language function and regional glucose metabolism from FDG positron computed tomography were examined. Caudate metabolism correlated with PICA speaking and comprehension factors, as well as BDAE mean writing and reading scores. To identify the language function implicated with caudate metabolism in these eleven patients, twenty subtests making up these two PICA factors and mean BDAE scores were correlated to caudate metabolism. Also a principle components analysis on the twenty subtests identified three factors, only one of which correlated with caudate metabolism. Evidence was found that the caudate has a functional relationship to recognition or motor planning of simple and overlearned materials. This involved simple syntax, low levels of abstraction, identification or sequencing of phonetic and semantic material. This role appeared related to but independent of Broca and frontal lobe function, and may involve the focusing of cortical functions, by allowing two or more regions to interact together

  17. Axial skeletal CT densitometry

    International Nuclear Information System (INIS)

    Lampmann, L.E.H.

    1982-01-01

    Since the discovery of the Roentgen ray a precise and accurate assessment of bone mineral content has been a challenge to many investigators. A number of methods have been developed but no one satisfied. Considering its technical possibilities computed tomography is very promising in determination of bone mineral content (BMC). The new modality enables BMC estimations in the axial skeletal trabecular bone. CT densitometry can be performed on a normal commercially available third generation whole body CT scanner. No dedicated device in a special clinical set-up is necessary. In this study 106 patients, most of them clinically suspected of osteoporosis, were examined. The new method CT densitometry has been evaluated. The results have been correlated to alternative BMC determination methods. (Auth.)

  18. Safety of intravenous tissue plasminogen activator administration with computed tomography evidence of prior infarction.

    Science.gov (United States)

    Lyerly, Michael J; Houston, J Thomas; Boehme, Amelia K; Albright, Karen C; Bavarsad Shahripour, Reza; Palazzo, Paola; Alvi, Muhammed; Rawal, Pawan V; Kapoor, Niren; Sisson, April; Alexandrov, Anne W; Alexandrov, Andrei V

    2014-07-01

    Prior stroke within 3 months excludes patients from thrombolysis; however, patients may have computed tomography (CT) evidence of prior infarct, often of unknown time of origin. We aimed to determine if the presence of a previous infarct on pretreatment CT is a predictor of hemorrhagic complications and functional outcomes after the administration of intravenous (IV) tissue plasminogen activator (tPA). We retrospectively analyzed consecutive patients treated with IV tPA at our institution from 2009-2011. Pretreatment CTs were reviewed for evidence of any prior infarct. Further review determined if any hemorrhagic transformation (HT) or symptomatic intracerebral hemorrhage (sICH) were present on repeat CT or magnetic resonance imaging. Outcomes included sICH, any HT, poor functional outcome (modified Rankin Scale score of 4-6), and discharge disposition. Of 212 IV tPA-treated patients, 84 (40%) had evidence of prior infarct on pretreatment CT. Patients with prior infarcts on CT were older (median age, 72 versus 65 years; P=.001) and had higher pretreatment National Institutes of Health Stroke Scale scores (median, 10 versus 7; P=.023). Patients with prior infarcts on CT did not experience more sICH (4% versus 2%; P=.221) or any HT (18% versus 14%; P=.471). These patients did have a higher frequency of poor functional outcome at discharge (82% versus 50%; P<.001) and were less often discharged to home or inpatient rehabilitation center (61% versus 73%; P=.065). Visualization of prior infarcts on pretreatment CT did not predict an increased risk of sICH in our study and should not be viewed as a reason to withhold systemic tPA treatment after clinically evident strokes within 3 months were excluded. Published by Elsevier Inc.

  19. Characterization of electrical properties in axial Si-Ge nanowire heterojunctions using off-axis electron holography and atom-probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gan, Zhaofeng [Department of Physics, Arizona State University, Tempe, Arizona 85287, USA; Perea, Daniel E. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Yoo, Jinkyoung [Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; He, Yang [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pennsylvania 15261, USA; Colby, Robert J. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Barker, Josh E. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Gu, Meng [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Mao, Scott X. [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pennsylvania 15261, USA; Wang, Chongmin [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Picraux, S. T. [Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Smith, David J. [Department of Physics, Arizona State University, Tempe, Arizona 85287, USA; McCartney, Martha R. [Department of Physics, Arizona State University, Tempe, Arizona 85287, USA

    2016-09-13

    Doped Si-Ge nanowire (NW) heterojunctions were grown using the vapor-liquid-solid method with AuGa and Au catalyst particles. Transmission electron microscopy and off-axis electron holography (EH) were used to characterize the nanostructure and to measure the electrostatic potential profile across the junction resulting from electrically active dopants, while atom-probe tomography (APT) was used to determine the Si, Ge and total (active and inactive) dopant concentration profiles. A comparison of the measured potential profile with simulations indicated that Ga dopants unintentionally introduced during AuGa catalyst growth were electronically inactive despite APT results that showed considerable amounts of Ga in the Si region. 10% P in Ge and 100% B in Si were estimated to be activated, which was corroborated by in situ electron-holography biasing experiments. This combination of EH, APT, in situ biasing and simulations allows a better knowledge and understanding of the electrically active dopant distributions in NWs.

  20. Cone-beam computed tomography: time for an evidence-based approach.

    Science.gov (United States)

    Horner, Keith

    2013-01-01

    Cone-beam computed tomography (CBCT) is an imaging technology that has revolutionised dental imaging in the last decade. Although of particular value to specialists performing implant treatment, it is increasingly being adopted by general dental practitioners. As the radiation dose is higher than that of conventional radiography, it is important to consider its diagnostic efficacy for the common tasks performed in general dental practice, such as caries diagnosis, endodontics and the detection of periapical pathosis. Any new imaging technique needs to have proven advantages over existing techniques before it is adopted, yet the evidence remains quite limited. Furthermore, image quality and radiation doses vary enormously between different manufacturers' equipment, so that extrapolating results of one piece of research from one CBCT machine to another is fraught with pitfalls. Radiation doses with CBCT are typically an order of magnitude higher than conventional radiography. There is scope, however, for reducing these doses by judicious adjustment of exposure factors and limiting the field of view to the smallest dimensions consistent with the clinical situation. There is still a long way to go before we understand the value of CBCT in dentistry. High quality research evidence is needed, particularly with regard to assessing whether using BCT improves patient outcomes.

  1. Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis

    Science.gov (United States)

    Armstrong, James J.; Pintwala, Robert; Hutnik, Cindy

    2018-01-01

    Purpose Early detection, monitoring and understanding of changes in the retina are central to the diagnosis of glaucomatous optic neuropathy, and vital to reduce visual loss from this progressive condition. The main objective of this investigation was to compare glaucoma diagnostic accuracy of commercially available optical coherence tomography (OCT) devices (Zeiss Stratus, Zeiss Cirrus, Heidelberg Spectralis and Optovue RTVue, and Topcon 3D-OCT). Patients 16,104 glaucomatous and 11,543 normal eyes reported in 150 studies. Methods Between Jan. 2017 and Feb 2017, MEDLINE®, EMBASE®, CINAHL®, Cochrane Library®, Web of Science®, and BIOSIS® were searched for studies assessing glaucoma diagnostic accuracy of the aforementioned OCT devices. Meta-analysis was performed pooling area under the receiver operating characteristic curve (AUROC) estimates for all devices, stratified by OCT type (RNFL, macula), and area imaged. Results 150 studies with 16,104 glaucomatous and 11,543 normal control eyes were included. Key findings: AUROC of glaucoma diagnosis for RNFL average for all glaucoma patients was 0.897 (0.887–0.906, n = 16,782 patient eyes), for macula ganglion cell complex (GCC) was 0.885 (0.869–0.901, n = 4841 eyes), for macula ganglion cell inner plexiform layer (GCIPL) was 0.858 (0.835–0.880, n = 4211 eyes), and for total macular thickness was 0.795 (0.754–0.834, n = 1063 eyes). Conclusion The classification capability was similar across all 5 OCT devices. More diagnostically favorable AUROCs were demonstrated in patients with increased glaucoma severity. Diagnostic accuracy of RNFL and segmented macular regions (GCIPL, GCC) scans were similar and higher than total macular thickness. This study provides a synthesis of contemporary evidence with features of robust inclusion criteria and large sample size. These findings may provide guidance to clinicians when navigating this rapidly evolving diagnostic area characterized by numerous options. PMID:29300765

  2. The Formation of Laurentia: Evidence from Shear Wave Splitting and Seismic Tomography

    Science.gov (United States)

    Liddell, M. V.; Bastow, I. D.; Rawlinson, N.; Darbyshire, F. A.; Gilligan, A.

    2017-12-01

    The northern Hudson Bay region of Canada comprises several Archean cratonic nuclei, assembled by Paleoproterozoic orogenies including the 1.8 Ga Trans-Hudson Orogen (THO) and Rinkian-Nagssugtoqidian Orogen (NO). Questions remain about how similar in scale and nature these orogens were compared to modern orogens like the Himalayas. Also in question is whether the thick Laurentian cratonic root below Hudson Bay is stratified, with a seismically-fast Archean core underlain by a lower, younger, thermal layer. We investigate these problems via shear-wave splitting and teleseismic tomography using up to 25 years of data from 65 broadband seismic stations across northern Hudson Bay. The results of the complementary studies comprise the most comprehensive study to date of mantle seismic velocity and anisotropy in northern Laurentia. Splitting parameter patterns are used to interpret multiple layers, lithospheric boundaries, dipping anisotropy, and deformation zone limits for the THO and NO. Source-side waveguide effects from Japan and the Aleutian trench are observed despite the tomographic data being exclusively relative arrival time. Mitigating steps to ensure data quality are explained and enforced. In the Hudson Strait, anisotropic fast directions (φ) generally parallel the THO, which appears in tomographic images as a strong low velocity feature relative to the neighbouring Archean cratons. Several islands in northern Hudson Bay show short length-scale changes in φ coincident with strong velocity contrasts. These are interpreted as distinct lithospheric blocks with unique deformational histories, and point to a complex, rather than simple 2-plate, collisional history for the THO. Strong evidence is presented for multiple anisotropic layers beneath Archean zones, consistent with the episodic development model of cratonic keels (e.g., Yuan & Romanowicz 2010). We show via both tomographic inversion models and SKS splitting patterns that southern Baffin Island was

  3. Persistence with golimumab in immune-mediated rheumatic diseases: a systematic review of real-world evidence in rheumatoid arthritis, axial spondyloarthritis, and psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    Svedbom A

    2017-04-01

    estimates of OLE trials.Conclusion: The data reviewed in this study indicate that golimumab may have higher persistence than other TNFis, a notion that is supported by indirect comparisons of persistence data from OLEs of randomized controlled trials (RCTs. Furthermore, the study suggests that persistence may be lower in biologic-experienced compared with biologic-naive patients and higher in axial spondyloarthritis compared with rheumatoid arthritis and psoriatic arthritis. Keywords: golimumab, Simponi, Treatment persistence, drug survival, retention rates, real-world evidence (RWE

  4. Light axial vector mesons

    Science.gov (United States)

    Chen, Kan; Pang, Cheng-Qun; Liu, Xiang; Matsuki, Takayuki

    2015-04-01

    Inspired by the abundant experimental observation of axial-vector states, we study whether the observed axial-vector states can be categorized into the conventional axial-vector meson family. In this paper we carry out an analysis based on the mass spectra and two-body Okubo-Zweig-Iizuka-allowed decays. Besides testing the possible axial-vector meson assignments, we also predict abundant information for their decays and the properties of some missing axial-vector mesons, which are valuable for further experimental exploration of the observed and predicted axial-vector mesons.

  5. Positional Change of Optic Nerve Head Vasculature during Axial Elongation as Evidence of Lamina Cribrosa Shifting: Boramae Myopia Cohort Study Report 2.

    Science.gov (United States)

    Lee, Kyoung Min; Choung, Ho-Kyung; Kim, Martha; Oh, Sohee; Kim, Seok Hwan

    2018-03-12

    To investigate the positional change of central retinal vasculature and vascular trunk to deduce the change in the lamina cribrosa (LC) during axial elongation. Prospective cohort study. Twenty-three healthy myopic children (46 eyes). Participants had undergone a full ophthalmologic examination and axial length measurement every 6 months for 2 years. Using spectral-domain OCT, circle scans centered around the optic disc in the glaucoma progression analysis mode, which enabled capturing of the same positions throughout the entire study period, and enhanced depth imaging of the deep optic nerve head complex were performed. Infrared imaging of the circle scans was used to measure the changes in the angles between the first and final visits. The angle between the major superior and inferior retinal arteries was measured along the circle scan twice: from the center of the circle scan and from the central retinal vascular trunk, respectively. The positional change of the retinal vascular trunk also was measured. Change in vascular angle and position of vascular trunk with axial elongation and associated factors. The vascular angle measured from the center of the circle scan did not change (P = 0.247), whereas the angle measured from the central retinal arterial trunk decreased with axial elongation (P dragging (P dragging was associated with axial elongation (P dragging could not be explained fully by their combination. The major directionality of dragging was mostly to the nasal side of the optic disc, with large variations among participants. During axial elongation, the retinal vasculature at the posterior pole was unchanged, whereas the position of the central vascular trunk was dragged nasally. Because the central retinal vascular trunk is embedded in the LC, its dragging indicates nasal shifting of the LC, which could explain the vulnerability of myopic eyes to glaucomatous optic neuropathy. Copyright © 2018 American Academy of Ophthalmology. Published by

  6. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  7. Computerized Axial Tomography in thorax trauma

    International Nuclear Information System (INIS)

    Zuluaga, Alejandro

    1997-01-01

    The great presentation frequency and the high morbid mortality, make of the thorax trauma a topic of great importance and of constant investigation, where the images have been useful in the evaluation of lesions, to define pathologies, like guide for the drainage of pleural collections and other evaluations; the paper includes a protocol, mediastine, and lesions among other topics

  8. The heart of patients with aortic aneurysms: evidence from cardiac computed tomography.

    NARCIS (Netherlands)

    Stolzmann, P.; Phan, C.; Desbiolles, L.; Lachat, M.; Pfammatter, T.; Marincek, B.; Prokop, M.; Alkadhi, H.

    2009-01-01

    To determine in patients with abdominal aortic aneurysm (AAA) the coronary calcium burden and prevalence of coronary artery disease (CAD) in relation to cardiovascular risk factors, and to assess the left ventricular (LV) function using cardiac computed tomography (CT). Sixty consecutive patients

  9. Wood anatomical correlates with theoretical conductivity and wood density across China: evolutionary evidence of the functional differentiation of axial and radial parenchyma.

    Science.gov (United States)

    Zheng, Jingming; Martínez-Cabrera, Hugo I

    2013-09-01

    In recent years considerable effort has focused on linking wood anatomy and key ecological traits. Studies analysing large databases have described how these ecological traits vary as a function of wood anatomical traits related to conduction and support, but have not considered how these functions interact with cells involved in storage of water and carbohydrates (i.e. parenchyma cells). We analyzed, in a phylogenetic context, the functional relationship between cell types performing each of the three xylem functions (conduction, support and storage) and wood density and theoretical conductivity using a sample of approx. 800 tree species from China. Axial parenchyma and rays had distinct evolutionary correlation patterns. An evolutionary link was found between high conduction capacity and larger amounts of axial parenchyma that is probably related to water storage capacity and embolism repair, while larger amounts of ray tissue have evolved with increased mechanical support and reduced hydraulic capacity. In a phylogenetic principal component analysis this association of axial parenchyma with increased conduction capacity and rays with wood density represented orthogonal axes of variation. In multivariate space, however, the proportion of rays might be positively associated with conductance and negatively with wood density, indicating flexibility in these axes in species with wide rays. The findings suggest that parenchyma types may differ in function. The functional axes represented by different cell types were conserved across lineages, suggesting a significant role in the ecological strategies of the angiosperms.

  10. Cervical Spinal Cord Injury without Computed Tomography Evidence of Trauma in Adults: Magnetic Resonance Imaging Prognostic Factors.

    Science.gov (United States)

    Martinez-Perez, Rafael; Munarriz, Pablo M; Paredes, Igor; Cotrina, Javier; Lagares, Alfonso

    2017-03-01

    Spinal cord injury (SCI) without computed tomography evidence of trauma is underreported in adults and is considered a subtype of SCI with relatively good outcome. Despite this, few studies have been performed to determine specific imaging-related prognostic factors. Our objective is to describe the imaging characteristics of patients experiencing blunt cervical spine trauma with neurologic deficits, but without radiologic abnormalities and associated prognostic factors. A retrospective review of all adult patients with cervical SCI admitted to the emergency room of 2 university hospitals from January 2004 to December 2013 was performed. Only patients with a magnetic resonance imaging (MRI) performed within 72 hours after trauma were included for further analysis. All patients with bony injury or traumatic malalignment were excluded. Data gathered on the remaining patients included demographics, mechanism of injury, severity of SCI, long-term patient outcome, improvement in neurologic condition, and MRI results. There were 48 patients who met the inclusion and exclusion criteria, and 40 who demonstrated improvement in the neurologic examination at follow-up. Disruption of either the anterior longitudinal ligament or ligamentum flavum and larger lesions in the MRI were predictors of lack of neurologic improvement. Early MRI has prognostic value in patients suffering SCI without computed tomography evidence of trauma. Lesion length is a powerful predictor of outcome in this subgroup of patients. Soft tissue injury plays a role in the severity of injury and the ability to recover in this subgroups of patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Axial and coronal orientation of subaxial cervical zygapophysial joints and their effect on axial rotation and lateral bending.

    Science.gov (United States)

    Hsu, Wen-Hsing; Benzel, Edward C; Chen, Tzu-Yung; Chen, Yao-Liang

    2008-10-15

    Computerized tomography and image processing methodologies were used to analyze the axial and coronal orientation of cervical zygapophysial joints in asymptomatic adults. Surface motions of axial rotation and lateral bending were simulated. The study was designed to obtain the normal distribution and variation of facet orientation (FO) in axial and coronal planes to investigate factors affecting FO and to study the effects of FO on axial rotation and lateral bending. The FO of the subaxial cervical spine is usually evaluated in the sagittal plane. Cervical spine axial and coronal FO is usually considered to be horizontal. The literature reveals no statistical data for axial or coronal FO. Serial thin-sliced computed tomography scans of the cervical spine in asymptomatic adults were input into Image J, National Institutes of Health, image processing software. Bilateral zygapophysial joint angles from C2-C3 to C6-C7 were measured in the axial and coronal planes and collected from 100 subjects. The effect of gender, age, and correlation was analyzed. The surface motions of axial rotation and lateral bending were simulated in Abaqus CAE 6.5. Mathematical facet contact and range of motion were computed. The FO was widely distributed at each level. Gender had no significant association with FO. Age affected FO at most levels. Axial and coronal FO were significantly correlated. The zygapophysial joint of internally rotated/inverted FO contacted more perpendicularly to each other, and mathematical range of motion was smaller. The axial or coronal FO of the subaxial cervical spine was found with more variability. Age was significantly related to FO. Geometrically, internally rotated/inverted FO of axial rotation/lateral bending was morerestricted. The extent of axial rotation and lateral bending was correlated with each other.

  12. Axial static mixer

    Science.gov (United States)

    Sandrock, H.E.

    1982-05-06

    Static axial mixing apparatus includes a plurality of channels, forming flow paths of different dimensions. The axial mixer includes a flow adjusting device for adjustable selective control of flow resistance of various flow paths in order to provide substantially identical flows through the various channels, thereby reducing nonuniform coating of interior surfaces of the channels. The flow adjusting device may include diaphragm valves, and may further include a pressure regulating system therefor.

  13. Positron Emission Tomography (PET) in the oncologic clinical practice

    International Nuclear Information System (INIS)

    Serna M, J.A.; Luviano, C.; Martinez V, D.; Maldonado S, A.

    2005-01-01

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  14. Cryoelectron Tomography of HIV-1 Envelope Spikes: Further Evidence for Tripod-Like Legs

    Science.gov (United States)

    Zhu, Ping; Winkler, Hanspeter; Chertova, Elena; Taylor, Kenneth A.; Roux, Kenneth H.

    2008-01-01

    A detailed understanding of the morphology of the HIV-1 envelope (Env) spike is key to understanding viral pathogenesis and for informed vaccine design. We have previously presented a cryoelectron microscopic tomogram (cryoET) of the Env spikes on SIV virions. Several structural features were noted in the gp120 head and gp41 stalk regions. Perhaps most notable was the presence of three splayed legs projecting obliquely from the base of the spike head toward the viral membrane. Subsequently, a second 3D image of SIV spikes, also obtained by cryoET, was published by another group which featured a compact vertical stalk. We now report the cryoET analysis of HIV-1 virion-associated Env spikes using enhanced analytical cryoET procedures. More than 2,000 Env spike volumes were initially selected, aligned, and sorted into structural classes using algorithms that compensate for the “missing wedge” and do not impose any symmetry. The results show varying morphologies between structural classes: some classes showed trimers in the head domains; nearly all showed two or three legs, though unambiguous three-fold symmetry was not observed either in the heads or the legs. Subsequently, clearer evidence of trimeric head domains and three splayed legs emerged when head and leg volumes were independently aligned and classified. These data show that HIV-1, like SIV, also displays the tripod-like leg configuration, and, unexpectedly, shows considerable gp41 leg flexibility/heteromorphology. The tripod-like model for gp41 is consistent with, and helps explain, many of the unique biophysical and immunological features of this region. PMID:19008954

  15. Cryoelectron tomography of HIV-1 envelope spikes: further evidence for tripod-like legs.

    Directory of Open Access Journals (Sweden)

    Ping Zhu

    2008-11-01

    Full Text Available A detailed understanding of the morphology of the HIV-1 envelope (Env spike is key to understanding viral pathogenesis and for informed vaccine design. We have previously presented a cryoelectron microscopic tomogram (cryoET of the Env spikes on SIV virions. Several structural features were noted in the gp120 head and gp41 stalk regions. Perhaps most notable was the presence of three splayed legs projecting obliquely from the base of the spike head toward the viral membrane. Subsequently, a second 3D image of SIV spikes, also obtained by cryoET, was published by another group which featured a compact vertical stalk. We now report the cryoET analysis of HIV-1 virion-associated Env spikes using enhanced analytical cryoET procedures. More than 2,000 Env spike volumes were initially selected, aligned, and sorted into structural classes using algorithms that compensate for the "missing wedge" and do not impose any symmetry. The results show varying morphologies between structural classes: some classes showed trimers in the head domains; nearly all showed two or three legs, though unambiguous three-fold symmetry was not observed either in the heads or the legs. Subsequently, clearer evidence of trimeric head domains and three splayed legs emerged when head and leg volumes were independently aligned and classified. These data show that HIV-1, like SIV, also displays the tripod-like leg configuration, and, unexpectedly, shows considerable gp41 leg flexibility/heteromorphology. The tripod-like model for gp41 is consistent with, and helps explain, many of the unique biophysical and immunological features of this region.

  16. [18F]Fludeoxyglucose-Positron Emission Tomography Evidence for Cerebral Hypermetabolism in the Awake State in Narcolepsy and Idiopathic Hypersomnia

    Directory of Open Access Journals (Sweden)

    Yves Dauvilliers

    2017-07-01

    Full Text Available BackgroundChanges in structural and functional central nervous system have been reported in narcolepsy, with large discrepancies between studies. No study has investigated yet spontaneous brain activity at wake in idiopathic hypersomnia (IH. We compared relative changes in regional brain metabolism in two central hypersomnia conditions with different clinical features, namely narcolepsy type 1 (NT1 and IH, and in healthy controls.MethodsSixteen patients [12 males, median age 30 years (17–78] with NT1, nine patients [2 males, median age 27 years (20–60] with IH and 19 healthy controls [16 males, median age 36 years (17–78] were included. 18F-fludeoxyglucose positron emission tomography (PET was performed in all drug-free subjects under similar conditions and instructions to stay in a wake resting state.ResultsWe found increased metabolism in the anterior and middle cingulate and the insula in the two pathological conditions as compared to healthy controls. The reverse contrast failed to evidence hypometabolism in patients vs. controls. Comparisons between patient groups were non-significant. At sub-statistical threshold, we found higher right superior occipital gyrus glucose metabolism in narcolepsy and higher middle orbital cortex and supplementary motor area metabolism in IH, findings that require further confirmation.ConclusionThere is significant hypermetabolism in narcolepsy and IH in the wake resting state in a set of brain regions constitutive of the salience cortical network that may reflect a compensatory neurocircuitry activity secondary to sleepiness. Metabolic differences between the two disorders within the executive-control network may be a signature of abnormally functioning neural system leading to persistent drowsiness typical of IH.

  17. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  18. Axial dispersion in a Kureha Crystal Purifier (KCP)

    Science.gov (United States)

    Otawara, K.; Matsuoka, T.

    2002-04-01

    It is widely accepted that the degree of axial back-mixing in the equipment affects the performance of a column crystallizer. Specifically, small such mixing is inevitable for obtaining highly pure crystal. In fact, it is believed that scale-up of some column crystallizers has been terminated due to the large axial back-mixing or maldistribution. Thus, experiments have been performed for estimating axial dispersion coefficients of liquid phase representing axial back-mixing in the column of a Kureha Crystal Purifier (KCP). The effect of the column diameter on such coefficients has been investigated and it has become evident that the axial back-mixing in the column is more significant in the larger column. Nevertheless, the results have also indicated that the axial back-mixing in KCPs of industrial sizes can be substantially smaller than those in other types of column crystallizers.

  19. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  20. Atlanto-Axial Subluxation After Adenoidectomy.

    Science.gov (United States)

    Gross, Isabel Theresia; Bahar-Posey, Laleh

    2017-06-01

    Atlanto-axial subluxation is a rare but potentially serious complication after otolaryngological procedures. We are describing a case of a 4-year-old child who developed atlanto-axial subluxation of the cervical spine after adenoidectomy. Our patient underwent adenoidectomy and, 18 days later, presented to the emergency department with her neck tilted to the left in a cock-robin position and complaining of neck pain persisting since the surgery. A multiplanar 3-dimensional computed tomography was obtained and confirmed the diagnosis of an atlanto-axial subluxation (Fielding type 3). She was managed conservatively with the application of a cervical collar, anti-inflammatory medication, and manual reduction under anesthesia later in the course because of persistence of her symptoms. It is important to consider this diagnosis in any child who undergoes ENT surgical procedures complaining of neck pain subsequent to surgery or holding the head in a fixed position persistently after surgery. Early diagnosis is important to reduce the time between the onset of symptoms and reduction to reduce the risk or need for surgical intervention.

  1. Compton backscattering axial spectrometer

    International Nuclear Information System (INIS)

    Rad'ko, V.E.; Mokrushin, A.D.; Razumovskaya, I.V.

    1981-01-01

    Compton gamma backscattering axial spectrometer of new design with the 200 time larger aperture as compared with the known spectrometers at the equal angular resolution (at E=159 keV) is described. Collimator unit, radiation source and gamma detector are located in the central part of the spectrometer. The investigated specimen (of cylindrical form) and the so called ''black body'' used for absorption of photons, passed through the specimen are placed in the peripheric part. Both these parts have an imaginary symmetry axis that is why the spectrometer is called axial. 57 Co is used as the gamma source. The 122 keV spectral line which corresponds to the 83 keV backscattered photon serves as working line. Germanium disk detector of 10 mm diameter and 4 mm height has energy resolution not worse than 900 eV. The analysis of results of test measurements of compton water profile and their comparison with data obtained earlier show that only finity of detector resolution can essentially affect the form of Compton profile. It is concluded that the suggested variant of the spectrometer would be useful for determination of Compton profiles of chemical compounds of heavy elements [ru

  2. Utilidad de la angiografía por tomografía axial computarizada en la evaluación anatómica de los pacientes pediátricos con cardiopatías congénitas Utility of computed axial tomography angiography in anatomic evaluation of pediatric patients with congenital heart diseases

    Directory of Open Access Journals (Sweden)

    Walter Mosquera A

    2007-12-01

    disponibles para el diagnóstico de este tipo de enfermedades.Antecedents: although echocardiogram and cardiac catheterization are used as first option tools for congenital heart diseases diagnosis, computed tomography angiography is a minimally invasive exam that through two to three dimensional images in real time gives an adequate approach to patients having this type of pathologies that require a rapid and precise evaluation of its extracardiac anatomy. Objective: describe the institutional experience from August 2005 to August 2006 in the use of angiography by tomography as a complementary diagnostic method in the evaluation of pediatric patients with congenital heart diseases. Method: serial descriptive study. 58 pediatric patients with clinical and echocardiographic diagnosis of congenital heart diseases were evaluated through the General Electric Multislice Lightpeed/16 scanner. Results: 58 patients with history of congenital heart disease were evaluated through CT angiography. Mean age was 2.4 ± 4.03 years. Twenty (33.8% had diagnosis of pulmonary atresia, four (6.7% had tricuspid atresia, eight (13.5% had double-outlet right ventricle, seven (11.8% had tetralogy of Fallot, nine (15.2% had alterations of the aortic arch, seven (11.8% had coarctation of the aorta, two (3.3% had interrupted aortic arch, six (10.3% had persistent ductus arteriosus, four (6.7% had anomalous venous drainage and three (5.1% had transposition of the great arteries. High quality images that allowed assessing the precise vascular anatomy were obtained. Conclusions: computed tomography angiography turned out to be a useful tool in the diagnostic approach of congenital heart diseases, because it allowed a tridimensional anatomic reconstruction. New studies that may permit the assessment of sensitivity, specificity and concordance level of this technique with other invasive diagnostic methods available for the diagnosis of this type of diseases, are required.

  3. Dissipative Axial Inflation

    CERN Document Server

    Notari, Alessio

    2016-12-22

    We analyze in detail the background cosmological evolution of a scalar field coupled to a massless abelian gauge field through an axial term $\\frac{\\phi}{f_\\gamma} F \\tilde{F}$, such as in the case of an axion. Gauge fields in this case are known to experience tachyonic growth and therefore can backreact on the background as an effective dissipation into radiation energy density $\\rho_R$, which which can lead to inflation without the need of a flat potential. We analyze the system, for momenta $k$ smaller than the cutoff $f_\\gamma$, including numerically the backreaction. We consider the evolution from a given static initial condition and explicitly show that, if $f_\\gamma$ is smaller than the field excursion $\\phi_0$ by about a factor of at least ${\\cal O} (20)$, there is a friction effect which turns on before that the field can fall down and which can then lead to a very long stage of inflation with a generic potential. In addition we find superimposed oscillations, which would get imprinted on any kind of...

  4. Characterization of Multiflux Axial Compressors

    International Nuclear Information System (INIS)

    Brasnarof, Daniel; Kyung Kyu-Hyung; Rivarola, Martin; Gonzalez Jose; Florido, Pablo; Orellano, Pablo; Bergallo, Juan

    2003-01-01

    In the present work the results of analytical models of performance are compared with experimental data acquired in the multi flux axial compressor test facility, built in The Pilcaniyeu Technological Complex for the SIGMA project.We describe the experimental circuit and the data of the dispersion inside the axial compressor obtained using a tracer gas through one of the annular inlets.The attained results can be used to validate the design code for the multi flux axial compressors and SIGMA industrial plant

  5. Linking Intra-Aggregate Pore Size Distribution with Organic Matter Decomposition Status, Evidence from FTIR and X-Ray Tomography

    Science.gov (United States)

    Toosi, E. R.; Quigley, M.; Kravchenko, A. N.

    2014-12-01

    It has been reported that conversion of intensively cultivated lands to less disturbed systems enhances soil OM storage capacity, primarily through OM stabilization in macroaggregates. We hypothesized that the potential for OM stabilization inside macro-aggregates is influenced by presence and abundance of intra-aggregate pores. Pores determine microbial access to OM and regulate diffusion of solution/gases within aggregates which drives microbial functioning. We investigated the influence of longterm disturbance intensity on soil OM composition and its relation to pore size distribution within macroaggregates. We used quantitative FTIR to determine OM decomposition status and X-ray micro-tomography to assess pore size distribution in macroaggregates as affected by management and landuse. Macroaggregates 4-6 mm in size where selected from topsoil under long term conventional tillage (CT), cover-crop (CC), and native succession vegetation (NS) treatments at Kellogg Biological Station, Michigan. Comparison of main soil OM functional groups suggested that with increasing disturbance intensity, the proportion of aromatic and carboxylic/carbohydrates associated compounds increased and it was concomitant with a decrease in the proportion of aliphatic associated compounds and lignin derivatives. Further, FTIR-based decomposition indices revealed that overall decomposition status of macroaggregates followed the pattern of CT > CC ≈ NS. X-ray micro-tomography findings suggested that greater OM decomposition within the macroaggregates was associated with i) greater percent of pores >13 micron in size within the aggregates, as well as ii) greater proportion of small to medium pores (13-110 micron). The results develop previous findings, suggesting that shift in landuse or management indirectly affects soil OM stabilization through alteration of pore size distribution within macroaggregates that itself, is coupled with OM decomposition status.

  6. Fluorescence axial nanotomography with plasmonics.

    Science.gov (United States)

    Cade, Nicholas I; Fruhwirth, Gilbert O; Krasavin, Alexey V; Ng, Tony; Richards, David

    2015-01-01

    We present a novel imaging technique with super-resolution axial sensitivity, exploiting the changes in fluorescence lifetime above a plasmonic substrate. Using conventional confocal fluorescence lifetime imaging, we show that it is possible to deliver down to 6 nm axial position sensitivity of fluorophores in whole biological cell imaging. We employ this technique to map the topography of the cellular membrane, and demonstrate its application in an investigation of receptor-mediated endocytosis in carcinoma cells.

  7. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  8. Evident?

    DEFF Research Database (Denmark)

    Plant, Peter

    2012-01-01

    Quality assurance and evidence in career guidance in Europe are often seen as self-evident approaches, but particular interests lie behind......Quality assurance and evidence in career guidance in Europe are often seen as self-evident approaches, but particular interests lie behind...

  9. Bone formation in axial spondyloarthritis.

    Science.gov (United States)

    Lories, Rik J; Haroon, Nigil

    2014-10-01

    The success of targeted therapies directed against tumor necrosis factor for patients with spondyloarthritis has shifted the focus of physicians and scientists towards the prevention of structural damage to the involved structures, in particular the sacroiliac joints and the spine, to avoid loss of function and disability. Structural damage to the skeleton as witnessed by radiography mainly consists of new bone formation potentially progressively leading to spine or joint ankylosis. This important long-term outcome parameter has been difficult to study, not alone because the time window for change may be long but also because human tissues with direct translational relevance are rarely available. Data from rodent models have identified growth factor signaling pathways as relevant targets. Both human and animal studies have tried to understand the link between inflammation and new bone formation. At the current moment, most evidence points towards a strong link between both but with the question still lingering about the sequence of events, disease triggers, and the interdependence of both features of disease. New discoveries such as a masterswitch T cell population that carries the IL23 receptor and the analysis of auto-antibodies directed again noggin and sclerostin are contributing to innovative insights into the pathophysiology of disease. Long-term data with tumor necrosis factor (TNF) inhibitors also suggest that some window of opportunity may exist to inhibit structural disease progression. All these data provide support for a further critical analysis of the available datasets and boost research in the field. The introduction of novel disease definitions, in particular the characterization of non-radiographic axial spondyloarthritis patients, will likely be instrumental in our further understanding of structural damage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Positron Emission Tomography (PET) in the oncologic clinical practice; Tomografia por Emision de Positrones (PET) en la practica clinica oncologica

    Energy Technology Data Exchange (ETDEWEB)

    Serna M, J.A.; Luviano, C.; Martinez V, D. [Hospital Angeles del Pedregal Mexico DF (Mexico); Maldonado S, A. [Centro PET Complutense, Madrid (Spain)

    2005-07-01

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  11. Variable polarisation and Doppler tomography of PSR J1023+0038 - Evidence for the magnetic propeller during flaring?

    Science.gov (United States)

    Hakala, Pasi; Kajava, Jari J. E.

    2018-03-01

    Transitional millisecond pulsars are systems that alternate between an accreting low-mass X-ray binary (LMXB) state and a non-accreting radio pulsar state. When at the LMXB state, their X-ray and optical light curves show rapid flares and dips, the origin of which is not well understood. We present results from our optical and NIR observing campaign of PSR J1023+0038, a transitional millisecond pulsar observed in an accretion state. Our wide-band optical photopolarimetry indicates that the system shows intrinsic linear polarisation, the degree of which is anticorrelated with optical emission, i.e. the polarisation could be diluted during the flares. However, the change in position angle during the flares suggests an additional emerging polarised component during the flares. We also find, based on our H α spectroscopy and Doppler tomography, that there is indication for change in the accretion disc structure/emission during the flares, possibly due to a change in accretion flow. This, together with changing polarisation during the flares, could mark the existence of magnetic propeller mass ejection process in the system. Furthermore, our analysis of flare profiles in both optical and NIR shows that NIR flares are at least as powerful as the optical ones and both can exhibit transition time-scales less than 3 s. The optical/NIR flares therefore seem to originate from a separate, polarised transient component, which might be due to Thomson scattering from propeller ejected matter.

  12. Organo-axial volvulus of the small intestine: radiological case report and consideration for its mechanism.

    Science.gov (United States)

    Ishiguro, Toshitaka; Hiyama, Takashi; Nasu, Katsuhiro; Akashi, Yoshimasa; Minami, Manabu

    2017-07-01

    Gastrointestinal volvulus is mainly classified into two subtypes, mesentero-axial volvulus and organo-axial volvulus. The detailed imaging findings of organo-axial volvulus of the small intestine have never been reported as far as we know. In this article, we report a case of organo-axial volvulus of the small intestine, focusing on the computed tomography (CT) findings. An 80-year-old man was radiologically diagnosed as having organo-axial volvulus of the terminal ileum and it was confirmed by open surgery without adhesion or any other anatomical abnormalities. CT showed two specific findings, split-bowel sign and rotating-C sign, which we think reflect pathophysiologic features of organo-axial volvulus. We think the pathogenic mechanism of organo-axial volvulus can be explained by the convergence of the reversed-rotational twist following the formation of a twisted but non-obstructive circular loop, even if there is no adhesion. Radiologists should be aware that organo-axial volvulus can occur even in the small intestine, and in the case of small bowel obstruction with single transition point, the two pathophysiologic signs mentioned above must be looked for to diagnose the possibility of organo-axial volvulus.

  13. Evidence of neurofibromatosis type 1 in a multi-morbid Inca child mummy: A paleoradiological investigation using computed tomography.

    Science.gov (United States)

    Panzer, Stephanie; Wittig, Holger; Zesch, Stephanie; Rosendahl, Wilfried; Blache, Sandra; Müller-Gerbl, Magdalena; Hotz, Gerhard

    2017-01-01

    In this study, an Inca bundle was examined using computed tomography (CT). The primary aim was to determine the preservation status of bony and soft tissues, the sex, the age at the time of death, possible indicators for disease or even the cause of death, as well as the kind of mummification. A secondary aim was to obtain a brief overview of the wrapping in order to gain additional information on the cultural background. The bundle belongs to the Museum of Cultures in Basel, Switzerland, and was bought in Munich, Germany, in 1921. Radiocarbon dating of the superficial textile yielded a calibrated age between 1480 and 1650 AD. The mummy was investigated using multi-slice CT with slice thickness of 0.75 mm and 110 kilovolt. For standardized assessment of soft tissue preservation, a recently developed checklist was applied. CT revealed the mummy of a seven to nine year old boy with superior preservation of bony and soft tissues allowing detailed assessment. Indicators of neurofibromatosis type 1 (paravertebral and cutaneous neurofibromas, a breast neurofibroma, sphenoid wing dysplasia), Chagas disease (dilatation of the esophagus, stomach, rectum, and large amounts of feces), and lung infection (pleural adherence, calcifications), probably due to tuberculosis, were found. Furthermore, signs of peri-mortem violence (transection of the chest and a defect in the abdominal wall) were detected. CT images revealed a carefully performed wrapping. CT examination of the Inca bundle proved to be an important non-destructive examination method. Standardized assessment, especially of the soft tissue structures, allowed for diagnoses of several diseases, indicating a multi-morbid child at the time of death. The careful wrapping pointed to a ceremonial burial. Within the cultural background, the signs of fatal violence were discussed as a possible result of war, murder, accident, or human sacrifice.

  14. Technical foundations and progress of the axial tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1980-01-01

    The X-ray-source is rotating about the object (or the object is rotating). Opposite is rotating an X-ray-image intensifier and a conventional television scanning technique. For tomographic application the total effective field is constrained by a diaphragm of the X-rays to a slit defining the slice under observation and hence the corresponding profile. The X-ray-beam source and the slit-diaphragm are rotating 180 deg around the object. For any angle the profile can be obtained as an electric signal in a time-domain by applying television technique: an X-ray image intensifier with a television-camera. A tomographic picture is the result by back-projection of the various profiles ('electronic spreading') and a process of integration ('deflection'), accumulation and storage of the density profiles. A second method is discussed: the X-ray-source-detector-system is rotating around the object and simultaneous displacing longitudinal. The detector sends its impulses to an electronic storage, off that the images can be successive transferred to a monitor. So quickly shifting the layers we obtain spatial pictures. (orig.) [de

  15. Axial Confocal Tomography of Capillary-Contained Colloidal Structures

    NARCIS (Netherlands)

    Liber, Shir R.; Indech, Ganit; Wee, Van Der Ernest B.; Butenko, Alexander V.; Kodger, Thomas E.; Lu, Peter J.; Schofield, Andrew B.; Weitz, David A.; Blaaderen, Van Alfons; Sloutskin, Eli

    2017-01-01

    Confocal microscopy is widely used for three-dimensional (3D) sample reconstructions. Arguably, the most significant challenge in such reconstructions is posed by the resolution along the optical axis being significantly lower than in the lateral directions. In addition, the imaging rate is lower

  16. Optical Coherence Tomography Monitoring Strategies for A-VEGF-Treated Age-Related Macular Degeneration: An Evidence-Based Analysis.

    Science.gov (United States)

    Pron, G

    2014-01-01

    New anti-angiogenesis pharmacotherapies have dramatically altered treatment of age-related macular degeneration (AMD), the leading cause of blindness in older adults. Monthly intraocular injections however, are extremely burdensome to ophthalmologists, patients, and their families. Repeated injections also increase risks of complications or adverse events. Although the pharmacokinetics of anti-vascular endothelial growth factor (A-VEGF) drugs are fairly well known, an individuals' AMD presentation and their pharmacodynamics or response to the drug has been shown to be extremely variable. Therefore treating everyone on the same fixed or standard regimen has potential for undertreating or overtreating patients, and drug costs are not trivial. To review monitoring strategies and to evaluate the role of optical coherence tomography (OCT) in guiding management of A-VEGF-treated neovascular AMD (n-AMD) patients. Systematic reviews of biographic databases for studies published between 2008 and February 2013 involving A-VEGF-treated n-AMD patients monitored in longitudinal follow-up. Studies were grouped according to varying treatments, monitoring schedules, and re-treatment protocols reported for n-AMD patients treated with A-VEGF. Several outcomes were evaluated across strategies including visual acuity (VA), retinal anatomy, re-treatment criteria and frequencies of clinical follow-up, OCT imaging investigations, and intravitreal injections. Results were summarized qualitatively, as heterogeneity in study objectives and methods precluded formal meta-analysis. A systematic review identified 18 randomized controlled trials (RCTs) and 20 observational studies involving A-VEGF treatment employing various monitoring and as-needed (PRN) re-treatment protocols. Several maintenance strategies were unsuccessful, resulting in lower VA gains and stabilization than monthly injections in A-VEGF-treated n-AMD. These included fixed quarterly treatment; fixed quarterly monitoring and

  17. Optical Coherence Tomography Monitoring Strategies for A-VEGF—Treated Age-Related Macular Degeneration: An Evidence-Based Analysis

    Science.gov (United States)

    Pron, G

    2014-01-01

    Background New anti-angiogenesis pharmacotherapies have dramatically altered treatment of age-related macular degeneration (AMD), the leading cause of blindness in older adults. Monthly intraocular injections however, are extremely burdensome to ophthalmologists, patients, and their families. Repeated injections also increase risks of complications or adverse events. Although the pharmacokinetics of anti–vascular endothelial growth factor (A-VEGF) drugs are fairly well known, an individuals’ AMD presentation and their pharmacodynamics or response to the drug has been shown to be extremely variable. Therefore treating everyone on the same fixed or standard regimen has potential for undertreating or overtreating patients, and drug costs are not trivial. Objectives To review monitoring strategies and to evaluate the role of optical coherence tomography (OCT) in guiding management of A-VEGF–treated neovascular AMD (n-AMD) patients. Data Sources Systematic reviews of biographic databases for studies published between 2008 and February 2013 involving A-VEGF–treated n-AMD patients monitored in longitudinal follow-up. Review Methods Studies were grouped according to varying treatments, monitoring schedules, and re-treatment protocols reported for n-AMD patients treated with A-VEGF. Several outcomes were evaluated across strategies including visual acuity (VA), retinal anatomy, re-treatment criteria and frequencies of clinical follow-up, OCT imaging investigations, and intravitreal injections. Results were summarized qualitatively, as heterogeneity in study objectives and methods precluded formal meta-analysis. Results A systematic review identified 18 randomized controlled trials (RCTs) and 20 observational studies involving A-VEGF treatment employing various monitoring and as-needed (PRN) re-treatment protocols. Several maintenance strategies were unsuccessful, resulting in lower VA gains and stabilization than monthly injections in A-VEGF–treated n-AMD. These

  18. Neurotransmitters behind pain relief with transcranial magnetic stimulation - positron emission tomography evidence for release of endogenous opioids.

    Science.gov (United States)

    Lamusuo, S; Hirvonen, J; Lindholm, P; Martikainen, I K; Hagelberg, N; Parkkola, R; Taiminen, T; Hietala, J; Helin, S; Virtanen, A; Pertovaara, A; Jääskeläinen, S K

    2017-10-01

    Repetitive transcranial magnetic stimulation (rTMS) at M1/S1 cortex has been shown to alleviate neuropathic pain. To investigate the possible neurobiological correlates of cortical neurostimulation for the pain relief. We studied the effects of M1/S1 rTMS on nociception, brain dopamine D2 and μ-opioid receptors using a randomized, sham-controlled, double-blinded crossover study design and 3D-positron emission tomography (PET). Ten healthy subjects underwent active and sham rTMS treatments to the right M1/S1 cortex with E-field navigated device. Dopamine D2 and μ-receptor availabilities were assessed with PET radiotracers [ 11 C]raclopride and [ 11 C]carfentanil after each rTMS treatment. Thermal quantitative sensory testing (QST), contact heat evoked potential (CHEP) and blink reflex (BR) recordings were performed between the PET scans. μ-Opioid receptor availability was lower after active than sham rTMS (P ≤ 0.0001) suggested release of endogenous opioids in the right ventral striatum, medial orbitofrontal, prefrontal and anterior cingulate cortices, and left insula, superior temporal gyrus, dorsolateral prefrontal cortex and precentral gyrus. There were no differences in striatal dopamine D2 receptor availability between active and sham rTMS, consistent with lack of long-lasting measurable dopamine release. Active rTMS potentiated the dopamine-regulated habituation of the BR compared to sham (P = 0.02). Thermal QST and CHEP remained unchanged after active rTMS. rTMS given to M1/S1 activates the endogenous opioid system in a wide brain network associated with processing of pain and other salient stimuli. Direct enhancement of top-down opioid-mediated inhibition may partly explain the clinical analgesic effects of rTMS. Neurobiological correlates of rTMS for the pain relief are unclear. rTMS on M1/S1 with 11 C-carfentanyl-PET activates endogenous opioids. Thermal and heat pain thresholds remain unchanged. rTMS induces top-down opioid-mediated inhibition

  19. The deep structure of Axial Volcano

    Science.gov (United States)

    West, Michael Edwin

    The subsurface structure of Axial Volcano, near the intersection of the Juan de Fuca Ridge and the Cobb-Eickelberg seamount chain in the northeast Pacific, is imaged from an active source seismic experiment. At a depth of 2.25 to 3.5 km beneath Axial lies an 8 km x 12 km region of very low seismic velocities that can only be explained by the presence of magma. In the center of this magma storage chamber at 2--3.5 km below sea floor, the crust is at least 10--20% melt. At depths of 4--5 km there is evidence of additional low concentrations of magma (a few percent) over a larger area. In total, 5--11 km3 of magma are stored in the mid-crust beneath Axial. This is more melt than has been positively identified under any basaltic volcano on Earth. It is also far more than the 0.1--0.2 km3 emplaced during the 1998 eruption. The implied residence time in the magma reservoir of a few hundred to a few thousand years agrees with geochemical trends which suggest prolonged storage and mixing of magmas. The large volume of melt bolsters previous observations that Axial provides much of the material to create crust along its 50 km rift zones. A high velocity ring-shaped feature sits above the magma chamber just outside the caldera walls. This feature is believed to be the result of repeated dike injections from the magma body to the surface during the construction of the volcanic edifice. A rapid change in crustal thickness from 8 to 11 km within 15 km of the caldera implies focused delivery of melt from the mantle. The high flux of magma suggests that melting occurs deeper in the mantle than along the nearby ridge. Melt supply to the volcano is not connected to any plumbing system associated with the adjacent segments of the Juan de Fuca Ridge. This suggests that, despite Axial's proximity to the ridge, the Cobb hot spot currently drives the supply of melt to the volcano.

  20. [Inflammatory spinal diseases: axial spondyloarthritis : Central importance of imaging].

    Science.gov (United States)

    Baraliakos, X; Fruth, M; Kiltz, U; Braun, J

    2017-03-01

    The diagnosis of axial spondyloarthritis (axSpA) includes classical ankylosing spondylitis (AS) as well as earlier stages and abortive courses of the disease, in which structural alterations have not yet occurred. These are classified as non-radiographic axSpA (nr-axSpa). Inflammatory changes in the entire axial skeleton are characteristic for axSpA and can be visualized by magnetic resonance imaging (MRI), while in most patients structural alterations, such as new bone formation with syndesmophytes and ankylosis develop in the later course of the disease. These bony alterations can best be visualized by conventional radiography and by computed tomography. Certain MRI sequences are nowadays considered as the standard method for depiction of inflammatory changes in axSpA. The introduction of MRI has led to a paradigm shift for this disease because the inflammatory lesions characteristic for the disease can be visualized at an early stage using appropriate MRI sequences.

  1. Axial structure of the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Veronique Bernard; Latifa Elouadrhiri; Ulf-G Meissner

    2002-01-01

    We review the current status of experimental and theoretical understanding of the axial nucleon structure at low and moderate energies. Topics considered include (quasi)elastic (anti)neutrino-nucleon scattering, charged pion electroproduction off nucleons and ordinary as well as radiative muon capture on the proton.

  2. Axial stability of Taylor bubbles

    NARCIS (Netherlands)

    Lu, X.; Prosperetti, Andrea

    2006-01-01

    Long gas bubbles rising in a vertical tube are observed to lose axial symmetry and become unstable in a downward liquid flow. In this paper an approximate linear stability analysis of this phenomenon is presented. It is found that, under the combined effect of gravity and the pressure gradient which

  3. Computerized Tomography

    International Nuclear Information System (INIS)

    Mirell, S.G.

    1979-01-01

    The physical bases of computerized tomography are presented, the following items being discussed:attenuation of a photon beam by an absorbent material, reconstruction algorithms and detection systems. Image statistics is also presented. The emission computerized tomography is discussed. Clinical results of computerized tomography are presented. (M.A.) [pt

  4. The role of metabotropic glutamate receptor 5 in the pathogenesis of mood disorders and addiction:Combining preclinical evidence with human Positron Emission Tomography (PET studies

    Directory of Open Access Journals (Sweden)

    Sylvia eTerbeck

    2015-03-01

    Full Text Available In the present review, we deliver an overview of the involvement of metabotropic glutamate receptor 5 (mGluR5 activity and density in pathological anxiety, mood disorders and addiction. Specifically, we will describe mGluR5 studies in humans that employed Positron Emission Tomography (PET and combined the findings with preclinical animal research. This combined view of different methodological approaches — from basic neurobiological approaches to human studies — might give a more comprehensive and clinically relevant view of mGluR5 function in mental health than the view on preclinical data alone. We will also review the current research data on mGluR5 along the Research Domain Criteria (RDoC. Firstly, we found evidence of abnormal glutamate activity related to the positive and negative valence systems, which would suggest that antagonistic mGluR5 intervention has prominent anti-addictive, anti-depressive and anxiolytic effects. Secondly, there is evidence that mGluR5 plays in important role in systems for social functioning and the response to social stress. Finally, mGluR5’s important role in sleep homeostasis suggests that this glutamate receptor may play an important role in RDoC’s arousal and modulatory systems domain. Glutamate was previously mostly investigate in non-human studies, however initial human clinical PET research now also supports the hypothesis that, by mediating brain excitability, neuroplasticity and social cognition, abnormal metabotropic glutamate activity might predispose individuals to a broad range of psychiatric problems.

  5. Relation between axial length and ocular parameters

    Directory of Open Access Journals (Sweden)

    Xue-Qiu Yang

    2013-09-01

    Full Text Available AIM: To investigatethe relation between axial length(AL, age and ocular parameters.METHODS: A total of 360 subjects(360 eyeswith emmetropia or myopia were recruited. Refraction, center corneal thickness(CCT, AL, intraocular pressure(IOPwere measured by automatic-refractor, Pachymeter, A-mode ultrasound and non-contact tonometer, respectively. Corneal curvature(CC, anterior chamber depth(ACDand white-to-white distance(WWDwere measured by Orbscan II. Three dimensional frequency domain coherent optical tomography(3D-OCTwas used to examine the retinal nerve fiber layer thickness(RNFLT. The Pearson correlation coefficient(rand multiple regression analysis were performed to evaluate the relationship between AL, age and ocular parameters.RESULTS: The average AL was 24.15±1.26mm. With elongation of the AL, spherical equivalent(SE(r=-0.742,Pr=-0.395, Pr=-0.374, Pr=0.411, Pr=0.099, P=0.060and WWD(r=0.061, P=0.252. There was also a significant correlation between AL and age(P=0.001, SE(PPPCONCLUSION: In longer eyes, there is a tendency toward myopia, a flatter cornea, a deeper ACD and a thinner RNFLT. Age is an influencing factor for the AL as well.

  6. Axial Permanent Magnet Generator for Wearable Energy Harvesting

    DEFF Research Database (Denmark)

    Högberg, Stig; Sødahl, Jakob Wagner; Mijatovic, Nenad

    2016-01-01

    An increasing demand for battery-free electronics is evident by the rapid increase of wearable devices, and the design of wearable energy harvesters follows accordingly. An axial permanent magnet generator was designed to harvest energy from human body motion and supplying it to a wearable...... application. The design was approached from an lectromagnetic point of view in this article. Two types of axial flux permanent magnet generators were designed: one with an iron yoke, which is commonly used to reduce the machine volume and demand of permanent magnets, and a second without the iron yoke...

  7. Axial magnetic field produced by axially and radially magnetized permanent rings

    International Nuclear Information System (INIS)

    Peng, Q.L.; McMurry, S.M.; Coey, J.M.D.

    2004-01-01

    Axial magnetic fields produced by axially and radially magnetized permanent magnet rings were studied. First, the axial magnetic field produced by a current loop is introduced, from which the axial field generated by an infinitely thin solenoid and by an infinitely thin current disk can be derived. Then the axial fields produced by axially and by radially magnetized permanent magnet rings can be obtained. An analytic formula for the axial fields produced by two axially magnetized rings is given. A permanent magnet with a high axial gradient field is fabricated, the measured results agree with the theoretical calculation very well. As an example, the axial periodic field produced by an arrangement of alternating axially and radially magnetized rings has been discussed

  8. Industrial tomography applied to reactor safety

    International Nuclear Information System (INIS)

    Kruger, R.P.

    1977-01-01

    Work has begun which explores the use of Computed Axial Tomography (CAT), boundary detection, and internal surface reconstruction techniques in industrial nondestructive testing applications. This initial work is intended to inform the reader of the existence and interrelated nature of these techniques through the use of a realistic simulation of an industrial inspection problem

  9. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  10. Axial Lengths in Children with Recessive Cornea Plana.

    Science.gov (United States)

    Al Hazimi, Amro; Khan, Arif O

    2015-06-01

    While flat keratometry contributes to the hyperopia and associated refractive accommodative esotropia that is part of recessive cornea plana, whether or not axial lengths are abnormally short in the disease is unclear. In this study we assess this possibility. Prospective (2010-2012) axial length measurement (IOLmaster; Carl Zeiss, Oberkochen, Germany) of affected right eyes and comparison to right eyes with refractive accommodative esotropia only. Keratometry and refraction were also performed. For eight affected right eyes (age 10-12 years; seven families) axial length ranged from 21.46-24.80 mm (mean 23.34). Best corrected visual acuity ranged from 20/25 to 20/50, keratometry from 25.33-39.80 diopters (D) [mean 31.80], and refraction from +2.00 to +14.00 D (mean +7.22). For 50 control right eyes (age 4-12 years), axial length ranged from 19.87-23.66 mm (mean 21.6). Best-corrected visual acuity was 20/25 or better, keratometry ranged from 39.81-46.25 D (mean 42.42), and refraction from +2.25 to +8.00 D (mean 4.71). Axial lengths were longer in the affected group (2-tailed unpaired t-test p value 0.000005) despite greater hyperopia (2-tailed unpaired t-test p value 0.001). Despite greater hyperopia, axial lengths were longer in eyes with recessive cornea plana, evidence that axial lengths are not shortened by the disease. Keratometry in children with cornea plana was below the range of controls and was the major factor underlying the phenotype's hyperopia.

  11. Joint interpretation of seismic tomography and new magnetotelluric results provide evidence for support of high topography in the Southern Rocky Mountains and High Plains of eastern Colorado, USA

    Science.gov (United States)

    Feucht, D. W.; Sheehan, A. F.; Bedrosian, P.

    2015-12-01

    A recent magnetotelluric (MT) survey in central Colorado, USA, when interpreted alongside existing seismic tomography, reveals potential mechanisms of support for high topography both regionally and locally. Broadband and long period magnetotelluric data were collected at twenty-three sites along a 330 km E-W profile across the Southern Rocky Mountains and High Plains of central North America as part of the Deep RIFT Electrical Resistivity (DRIFTER) experiment. Remote-reference data processing yielded high quality MT data over a period range of 100 Hz to 10,000 seconds. A prominent feature of the regional geo-electric structure is the Denver Basin, which contains a thick package of highly conductive shales and porous sandstone aquifers. One-dimensional forward modeling was performed on stations within the Denver Basin to estimate depth to the base of this shallow conductor. Those estimates were then used to place a horizontal penalty cut in the model mesh of a regularized two-dimensional inversion. Two-dimensional modeling of the resistivity structure reveals two major anomalous regions in the lithosphere: 1) a high conductivity region in the crust under the tallest peaks of the Rocky Mountains and 2) a lateral step increase in lithospheric resistivity beneath the plains. The Rocky Mountain crustal anomaly coincides with low seismic wave speeds and enhanced heat flow and is thus interpreted as evidence of partial melt and/or high temperature fluids emplaced in the crust by tectonic activity along the Rio Grande Rift. The lateral variation in the mantle lithosphere, while co-located with a pronounced step increase in seismic velocity, appears to be a gradational boundary in resistivity across eastern Colorado and could indicate a small degree of compositional modification at the edge of the North American craton. These inferred conductivity mechanisms, namely crustal melt and modification of mantle lithosphere, likely contribute to high topography locally in the

  12. Computed tomography of the oropharynx in obstructive sleep apnea

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, S.G.; Gislason, T.; Lindholm, C.E.

    Computed tomography (CT) of the oropharynx was obtained in 32 consecutive adult patients with proven OSAS. An additional 15 patients with the same complaints, but without objective evidence of OSAS, were used as a control group, together with 20 normal subjects. The axial widths of the tongue and the genioglossus and hyoglossus muscles were measured by CT. Both the tongue and genioglossus widths were significantly larger in the OSAS patients than in the two control groups (p < 0.001). The increased tongue width will cause encroachment of the oropharyngeal airway below the level of the soft palate. Thus, CT can be used to measure the tongue size in order to evaluate its predictive value for the outcome of the UPPP procedure.

  13. Atlantoaxial dislocation with special emphasis on computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Kazuo; Isu, Toyohiko; Abe, Satoru; Takei, Hidetoshi; Irie, Goro

    1983-01-01

    In this study, the authors evaluated the effectiveness of computed tomography (CT) in the diagnosis of atlantoaxial dislocation (AAD). On the basis of CT evidence of Cl-2 interrelationship, AAD in 26 patients was classified into 4 major types; anteroposterior dislocation in 13 patients, transverse dislocation in 2, anteroposterior-transverse dislocation in 3, and rotatory dislocation in 8. A thick wad of soft tissue on the posterior aspect of the odontoid was found in as many as 38% of the patients and related to compromise the spinal canal. Association of atlantooccipital subluxation with AAD was not rarely encountered in this series (6 out of 26 patients). CT can most optimally and noninvasively demonstrate relationship among the occipitoatlanto-axial complex and associated soft tissue abnormalities. (author).

  14. Axial diagnostic package for Z

    International Nuclear Information System (INIS)

    Nash, T.J.; Derzon, M.S.; Chandler, G.

    1998-06-01

    The authors have developed and fielded an axial diagnostic package for the 20 MA, 100 ns, z-pinch driver Z. The package is used to diagnose dynamic hohlraum experiments which require an axial line of sight. The heart of the package is a reentrant cone originally used to diagnose ion-beam-driven hohlraums on PBFA-H. It has one diagnostic line of sight at 0 degrees, 4 at 6 degrees, and 4 at 9 degrees. In addition it has a number of viewing, alignment, and vacuum feedthrough ports. The front of the package sits approximately 5 feet from the pinch. This allows much closer proximity to the pinch, with inherently better resolution and signal, than is presently possible in viewing the pinch from the side. Debris that is preferentially directed along the axis is mitigated by two apertures for each line of sight, and by fast valves and imaging pinholes or cross slits for each diagnostic. In the initial run with this package they fielded a time resolved pinhole camera, a five-channel pinhole-apertured x-ray diode array, a bolometer, a spatially resolved time-integrated crystal spectrometer, and a spatially and temporally resolved crystal spectrometer. They present data obtained from these diagnostics in the dynamic hohlraum research conducted on Z

  15. Electric machines with axial magnetic flux

    Science.gov (United States)

    Nuca, I.; Ambros, T.; Burduniuc, M.; Deaconu, S. I.; Turcanu, A.

    2018-01-01

    The paper contains information on the performance of axial machines compared to cylindrical ones. At the same time, various constructive schemes of synchronous electromechanical converters with permanent magnets and asynchronous with short-circuited rotor are presented. In the developed constructions, the aim is to maximize the usage of the material of the stator windings. The design elements of the axial machine magnetic system are presented. The FEMM application depicted the array of the magnetic field of an axial machine.

  16. Axial vector mass spectrum and mixing angles

    International Nuclear Information System (INIS)

    Caffarelli, R.V.; Kang, K.

    1976-01-01

    Spectral sum rules of the axial-vector current and axial-vector current-pseudoscalar field are used to study the axial-vector mass spectrum and mixing angles, as well as the decay constants and mixing angles of the pseudoscalar mesons. In general, the result is quite persuasive for the existence of the Jsup(PC) = 1 ++ multiplet in which one has a canonical D-E mixing. (Auth.)

  17. Centrifugal and axial compressor control

    CERN Document Server

    McMillan, Gregory K

    2009-01-01

    Control engineers, mechanical engineers and mechanical technicians will learn how to select the proper control systems for axial and centrifugal compressors for proper throughput and surge control, with a particular emphasis on surge control. Readers will learn to understand the importance of transmitter speed, digital controller sample time, and control valve stroking time in helping to prevent surge. Engineers and technicians will find this book to be a highly valuable guide on compressor control schemes and the importance of mitigating costly and sometimes catastrophic surge problems. It can be used as a self-tutorial guide or in the classroom with the book's helpful end-of-chapter questions and exercises and sections for keeping notes.

  18. Axial channeling of uttrarelativistic electrons

    Energy Technology Data Exchange (ETDEWEB)

    Telegin, V.I.; Khokonov, M.Kh. (Moskovskij Gosudarstvennyj Univ. (USSR). Nauchno-Issledovatel' skij Inst. Yadernoj Fiziki)

    1982-07-01

    The dynamics of motion of ultrarelativistic electrons under axial channeling conditions is investigated. The analysis is based on the solution of the kinetic equation obtained recently by Beloshitsky and Kumakhov. The particle dechanneling function is investigated as depending on the type of a crystal, particle energy and angle of entrance into the single crystal. It is found that for most of the beam the major diffusion mechanism is scattering by electrons. It is shown that an optimal depth range exists for which the fraction of channeled particles sharply increases at the expense of the quasi-channeled particles. In a number of cases the dechanneling length for crystals with high atomic numbers may be greater than that of light elements.

  19. Axial channeling of uttrarelativistic electrons

    International Nuclear Information System (INIS)

    Telegin, V.I.; Khokonov, M.Kh.

    1982-01-01

    The dynamics of motion of ultrarelativistic electrons under axial channeling conditions is investigated. The analysis is based on the solution of the kinetic equation obtained recently by Beloshitsky and Kumakhov. The particle dechanneling function is investigated as depending on the type of a crystal, particle energy and angle of entrance into the single crystal. It is found that for most of the beam the major diffusion mechanism is scattering by electrons. It is shown that an optimal depth range exists for which the fraction of channeled particles sharply increases at the expense of the quasi-channeled particles. In a number of cases the dechanneling length for crystals with high atomic numbers may be greater than that of light elements

  20. Radial and axial compression of pure electron

    International Nuclear Information System (INIS)

    Park, Y.; Soga, Y.; Mihara, Y.; Takeda, M.; Kamada, K.

    2013-01-01

    Experimental studies are carried out on compression of the density distribution of a pure electron plasma confined in a Malmberg-Penning Trap in Kanazawa University. More than six times increase of the on-axis density is observed under application of an external rotating electric field that couples to low-order Trivelpiece-Gould modes. Axial compression of the density distribution with the axial length of a factor of two is achieved by controlling the confining potential at both ends of the plasma. Substantial increase of the axial kinetic energy is observed during the axial compression. (author)

  1. Axial and Radial Oxylipin Transport.

    Science.gov (United States)

    Gasperini, Debora; Chauvin, Adeline; Acosta, Ivan F; Kurenda, Andrzej; Stolz, Stéphanie; Chételat, Aurore; Wolfender, Jean-Luc; Farmer, Edward E

    2015-11-01

    Jasmonates are oxygenated lipids (oxylipins) that control defense gene expression in response to cell damage in plants. How mobile are these potent mediators within tissues? Exploiting a series of 13-lipoxygenase (13-lox) mutants in Arabidopsis (Arabidopsis thaliana) that displays impaired jasmonic acid (JA) synthesis in specific cell types and using JA-inducible reporters, we mapped the extent of the transport of endogenous jasmonates across the plant vegetative growth phase. In seedlings, we found that jasmonate (or JA precursors) could translocate axially from wounded shoots to unwounded roots in a LOX2-dependent manner. Grafting experiments with the wild type and JA-deficient mutants confirmed shoot-to-root oxylipin transport. Next, we used rosettes to investigate radial cell-to-cell transport of jasmonates. After finding that the LOX6 protein localized to xylem contact cells was not wound inducible, we used the lox234 triple mutant to genetically isolate LOX6 as the only JA precursor-producing LOX in the plant. When a leaf of this mutant was wounded, the JA reporter gene was expressed in distal leaves. Leaf sectioning showed that JA reporter expression extended from contact cells throughout the vascular bundle and into extravascular cells, revealing a radial movement of jasmonates. Our results add a crucial element to a growing picture of how the distal wound response is regulated in rosettes, showing that both axial (shoot-to-root) and radial (cell-to-cell) transport of oxylipins plays a major role in the wound response. The strategies developed herein provide unique tools with which to identify intercellular jasmonate transport routes. © 2015 American Society of Plant Biologists. All Rights Reserved.

  2. Study on optimization of the circumferential and axial wavy geometrical configuration of hydrodynamic journal bearing

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Xiaoping; Chen, Jin; Hussain, Sinan H [Chongqung University, Chongqing (China)

    2013-12-15

    This paper is focused on using GA genetic algorithm to find the optimal performance with respect to shape optimization in three dimensions for the hydrodynamic journal bearing. The mathematical model for film thickness was drawn using Fourier series function and axial waviness value (Δ) D to represent the journal bearing in circumferential and axial direction, respectively. The objective was then to determine the Fourier coefficients and axial waviness value (Δ) D that maximized the load capacity subjected to a given set of constraint. Optimized results show that the presence of cos wave in axial direction, with a positive dimensionless amplitude (+A) and waviness number m = 0.633, improves the load capacity by (8-10) % over the cylindrical plain bearing with the same arbitrary shape and size; in general, the increasing order of Fourier series (n), an axial dimensionless amplitude and L/D ratio cause the change in load capacity to become more evident.

  3. Transverse tomography and radiotherapy

    International Nuclear Information System (INIS)

    Leer, J.W.H.

    1982-01-01

    This study was intended to delineate the indications for radiotherapy treatment-planning with the help of computerized axial tomography (C.T.) and transverse analog tomography (T.A.T.). Radiotherapy localisation procedures with the conventional method (simulator), with the CT-scanner and with the transverse analog tomograph (T.A.T., Simtomix, Oldelft) were compared. As criterium for evaluation differences in reconstruction drawing based on these methods were used. A certain method was judged ''superior'' to another if the delineation of the target volume was more accurate, if a better impression was gained of the site of (for irradiation) organs at risk, or if the localisation could only be performed with that method. The selected group of patients consisted of 120 patients for whom a reconstruction drawing in the transverse plane was made according to the treatment philosophy. In this group CT-assisted localisation was judged on 68 occasions superior to the conventional method. In a number of cases it was found that a ''standard'' change in a standard target volume, on the base of augmented anatomical knowledge, made the conventional method sufficient. The use of CT-scanner for treatment planning was estimated. For ca. 270/1000 new patients a CT-scan is helpful (diagnostic scan), for 140 of them the scan is necessary (planning scan). The quality of the anatomical information obtained with the T.A.T. does not yet fall within acceptable limits, but progress has been made. (Auth.)

  4. Health and imaging outcomes in axial spondyloarthritis

    NARCIS (Netherlands)

    Machado, P.M.

    2016-01-01

    This thesis focuses on the assessment and monitoring of health and imaging outcomes in axial spondyloarthritis (SpA) and the relationship between these outcomes. Four major contributions to the understanding and management of axial SpA were made: 1) the improvement and facilitation of the assessment

  5. Aryabhata and Axial Rotation of Earth

    Indian Academy of Sciences (India)

    GENERAL I ARTICLE. Aryabhata and Axial Rotation of Earth. 3. A Brief History. Amartya Kumar Datta is in the Stat-Math Unit of. Indian Statistic.llnstiutte,. Kolkata. His research ... historical account of some of Aryabha~a's views on axial rotation of Earth, ..... and stress on periodic observations and updating of the parameters.

  6. Axial anomalies of Lifshitz fermions

    CERN Document Server

    Bakas, Ioannis

    2011-01-01

    We compute the axial anomaly of a Lifshitz fermion theory with anisotropic scaling z=3 which is minimally coupled to geometry in 3+1 space-time dimensions. We find that the result is identical to the relativistic case using path integral methods. An independent verification is provided by showing with spectral methods that the eta-invariant of the Dirac and Lifshitz fermion operators in three dimensions are equal. Thus, by the integrated form of the anomaly, the index of the Dirac operator still accounts for the possible breakdown of chiral symmetry in non-relativistic theories of gravity. We apply this framework to the recently constructed gravitational instanton backgrounds of Horava-Lifshitz theory and find that the index is non-zero provided that the space-time foliation admits leaves with harmonic spinors. Using Hitchin's construction of harmonic spinors on Berger spheres, we obtain explicit results for the index of the fermion operator on all such gravitational instanton backgrounds with SU(2)xU(1) isom...

  7. Conditions and mechanism for the appearance of interlobar fissures as 5-line signs in axial maximum intensity projection images.

    Science.gov (United States)

    Yu, Anle; Li, Qun; He, Jinlong; Zhan, Yuefu

    2014-01-01

    To assess the conditions and mechanism for the 5-line sign of normal interlobar fissures revealed on axial maximum intensity projection (MIP). Fifty subjects (32 males and 18 females aged 16 to 76 years) whose conditions were diagnosed as normal on computed tomography (CT) of the chest were presented. Images for the fissures with a slice thickness of 1.25 mm, a space thickness of 1.25 mm, and an MIP slab thickness of 6.25 mm were reconstructed. A 5-line shadow of normal interlobar fissures was shown on axial MIP imaging using a slab thickness of 6.25 mm. On axial MIP imaging, 93% of interlobar fissure parts were manifested as clear or barely clear. On axial MIP imaging using a slab thickness of 6.25 mm, normal interlobar fissures were displayed as 5-line signs, which, similar to the beaded small lung vessels shown on MIP imaging, might be a partial volume-averaging phenomenon.

  8. Diagnostic value of axial CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Kiuchi, Sousuke (Tsukuba Univ., Sakura, Ibaraki (Japan))

    1983-03-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal.

  9. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans

    2009-01-01

    force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...... documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe...

  10. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  11. An investigation of inconsistent projections and artefacts in multi-pinhole SPECT with axially aligned pinholes

    International Nuclear Information System (INIS)

    Kench, P L; Meikle, S R; Lin, J; Gregoire, M C

    2011-01-01

    Multiple pinholes are advantageous for maximizing the use of the available field of view (FOV) of compact small animal single photon emission computed tomography (SPECT) detectors. However, when the pinholes are aligned axially to optimize imaging of extended objects, such as rodents, multiplexing of the pinhole projections can give rise to inconsistent data which leads to 'ghost point' artefacts in the reconstructed volume. A novel four pinhole collimator with a baffle was designed and implemented to eliminate these inconsistent projections. Simulation and physical phantom studies were performed to investigate artefacts from axially aligned pinholes and the efficacy of the baffle in removing inconsistent data and, thus, reducing reconstruction artefacts. SPECT was performed using a Defrise phantom to investigate the impact of collimator design on FOV utilization and axial blurring effects. Multiple pinhole SPECT acquired with a baffle had fewer artefacts and improved quantitative accuracy when compared to SPECT acquired without a baffle. The use of four pinholes positioned in a square maximized the available FOV, increased acquisition sensitivity and reduced axial blurring effects. These findings support the use of a baffle to eliminate inconsistent projection data arising from axially aligned pinholes and improve small animal SPECT reconstructions.

  12. Capacitive axial position and speed transduction system

    International Nuclear Information System (INIS)

    Jimenez D, H.; Flores Ll, H.; Cabral P, A.; Ramirez J, F.J.; Galindo, S.

    1984-01-01

    A new and inexpensive circuit arrangement of a capacitive axial position and speed transduction system is described. Design details and the theory of operation of the device are briefly outlined together with performance results. (author)

  13. Two pad axially grooved hydrostatic bearing

    Science.gov (United States)

    San Andres, Luis A. (Inventor)

    1995-01-01

    A hydrostatic bearing having two axial grooves on opposite sides of the bearing for breaking the rotational symmetry in the dynamic force coefficients thus reducing the whirl frequency ratio and increasing the damping and stiffness of the hydrostatic bearing.

  14. High temperature co-axial winding transformers

    Science.gov (United States)

    Divan, Deepakraj M.; Novotny, Donald W.

    1993-01-01

    The analysis and design of co-axial winding transformers is presented. The design equations are derived and the different design approaches are discussed. One of the most important features of co-axial winding transformers is the fact that the leakage inductance is well controlled and can be made low. This is not the case in conventional winding transformers. In addition, the power density of co-axial winding transformers is higher than conventional ones. Hence, using co-axial winding transformers in a certain converter topology improves the power density of the converter. The design methodology used in meeting the proposed specifications of the co-axial winding transformer specifications are presented and discussed. The final transformer design was constructed in the lab. Co-axial winding transformers proved to be a good choice for high power density and high frequency applications. They have a more predictable performance compared with conventional transformers. In addition, the leakage inductance of the transformer can be controlled easily to suit a specific application. For space applications, one major concern is the extraction of heat from power apparatus to prevent excessive heating and hence damaging of these units. Because of the vacuum environment, the only way to extract heat is by using a cold plate. One advantage of co-axial winding transformers is that the surface area available to extract heat from is very large compared to conventional transformers. This stems from the unique structure of the co-axial transformer where the whole core surface area is exposed and can be utilized for cooling effectively. This is a crucial issue here since most of the losses are core losses.

  15. Axial model in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Barcelos-Neto, J.; Farina, C.; Vaidya, A.N.

    1986-12-11

    We study the axial model in a background gravitational field. Using the zeta-function regularization, we obtain explicitly the anomalous divergence of the axial-vector current and the exact generating functional of the theory. We show that, as a consequence of a space-time-dependent metric, all differential equations involved in the theory generalize to their covariantized forms. We also comment on the finite-mass renormalization exhibited by the pseudoscalar field and the form of the fermion propagator.

  16. Dechanneling function for relativistic axially channeled electrons

    International Nuclear Information System (INIS)

    Muralev, V.A.; Telegin, V.I.

    1981-01-01

    Behaviour of the x(t) dechanneling function depending on the depth is theoretically studied. Theoretical consideration of x(t) for axial channeled relativistic electrons in anisotropic medium results in two-dimensional kinetic equation with mixed derivatives of the parabolic type. The kinetic equation in the approximation of the continuous Lindchard model for relativistic axial channeled electrons is numerically solved. The depth dependence of the x(t) dechanneling function is obtained [ru

  17. Axial forces in centrifugal compressor couplings

    Science.gov (United States)

    Ivanov, A. N.; Ivanov, N. M.; Yun, V. K.

    2017-08-01

    The article presents the results of the theoretical and experimental investigation of axial forces arising in the toothed and plate couplings of centrifugal compressor shaft lines. Additional loads on the thrust bearing are considered that can develop in the toothed couplings as a result of coupled rotors misalignment. Design relationships to evaluate the level of axial forces and recommendations for their reduction in the operating conditions are given.

  18. High harmonic generation from axial chiral molecules.

    Science.gov (United States)

    Wang, Dian; Zhu, Xiaosong; Liu, Xi; Li, Liang; Zhang, Xiaofan; Lan, Pengfei; Lu, Peixiang

    2017-09-18

    Axial chiral molecules, whose stereogenic element is an axis rather than a chiral center, have attracted widespread interest due to their important application, such as asymmetric synthesis and chirality transfer. We investigate high harmonic generation from axial chiral molecules with bichromatic counterrotating circularly polarized laser fields. High harmonic generation from three typical molecules: (Sa)-3-chloropropa-1,2-dien-1-ol, propadiene, and (Ra)-2,3-pentadiene is simulated with time-dependent density-functional theory and strong field approximation. We found that harmonic spectra for 3D oriented axial chiral molecules exhibit obvious circular dichroism. However, the circular dichroism of High harmonic generation from an achiral molecule is much trivial. Moreover, the dichroism of high harmonic generation still exists when axial chiral molecules are 1D oriented,such as (Sa) -3-chloropropa-1,2-dien-1-ol. For a special form of axial chiral molecules with the formula abC=C=Cab (a, b are different substituents), like (Ra)-2,3-pentadiene, the dichroism discriminations disappear when the molecules are only in 1D orientation. The circular dichroism of high harmonic generation from axial chiral molecules is well explained by the trajectory analysis based on the semiclassical three-step mechanism.

  19. Unexplained heterochromia. Intraocular foreign body demonstrated by computed tomography.

    Science.gov (United States)

    Barr, C C; Vine, A K; Martonyi, C L

    1984-01-01

    Standard radiographic techniques are often inadequate in demonstrating the presence and location of intraocular foreign bodies. Computerized axial tomography was used to confirm the presence of a metallic foreign body in a patient with heterochromia iridis and suspected ocular siderosis in whom no foreign material was found by conventional examination methods.

  20. Estimation of axial curvature of anterior sclera: correlation between axial length and anterior scleral curvature as affected by angle kappa.

    Science.gov (United States)

    Lee, Sang-Mok; Choi, Hyuk Jin; Choi, Heejin; Kim, Mee Kum; Wee, Won Ryang

    2016-10-07

    BACKGROUND: Though the development and fitting of scleral contact lenses are expanding steadily, there is no simple method to provide scleral metrics for scleral contact lens fitting yet. The aim of this study was to establish formulae for estimation of the axial radius of curvature (ARC) of the anterior sclera using ocular biometric parameters that can be easily obtained with conventional devices. A semi-automated stitching method and a computational analysis tool for calculating ARC were developed by using the ImageJ and MATLAB software. The ARC of all the ocular surface points were analyzed from the composite horizontal cross-sectional images of the right eyes of 24 volunteers; these measurements were obtained using anterior segment optical coherence tomography for a previous study (AS-OCT; Visante). Ocular biometric parameters were obtained from the same volunteers with slit-scanning topography and partial coherence interferometry. Correlation analysis was performed between the ARC at 8 mm to the axis line (ARC[8]) and other ocular parameters (including age). With ARC obtained on several nasal and temporal points (7.0, 7.5, 8.0, 8.5, and 9.0 mm from the axis line), univariate and multivariate linear regression analyses were performed to develop a model for estimating ARC with the help of ocular biometric parameters. Axial length, spherical equivalent, and angle kappa showed correlations with temporal ARC[8] (tARC[8]; Pearson's r = 0.653, -0.579, and -0.341; P = 0.001, 0.015, and 0.015, respectively). White-to-white corneal diameter (WTW) and anterior chamber depth (ACD) showed correlation with nasal ARC[8] (nARC[8]; Pearson's r = -0.492 and -0.461; P = 0.015 and 0.023, respectively). The formulae for estimating scleral curvatures (tARC, nARC, and average ARC) were developed as a function of axial length, ACD, WTW, and distance from the axis line, with good determinant power (72 - 80 %; SPSS ver. 22.0). Angle kappa showed strong

  1. Is tomography of intervertebral disc calcification useful in children?

    International Nuclear Information System (INIS)

    Ginalski, J.M.; Landry, M.; Gudinchet, F.; Schnyder, P.

    1992-01-01

    In the past ten years, we have found cervical intervertebral disc calcification in three children on plain films of the cervical spine made because of cervical pain. In each case, we required further radiological investigations, antero-posterior and lateral linear tomography for two children and an axial computed tomography for one child. In each case, tomography revealed no supplementary useful information. On retrospect, we think that these examinations caused unnecessary irradiation and that they should only be carried out in the rare circumstances when disc calcification is associated with neurological symptoms. (orig.)

  2. The Sex and Race Specific Relationship between Anthropometry and Body Fat Composition Determined from Computed Tomography: Evidence from the Multi-Ethnic Study of Atherosclerosis.

    Science.gov (United States)

    Mongraw-Chaffin, Morgana; Golden, Sherita Hill; Allison, Matthew A; Ding, Jingzhong; Ouyang, Pamela; Schreiner, Pamela J; Szklo, Moyses; Woodward, Mark; Young, Jeffery Hunter; Anderson, Cheryl A M

    2015-01-01

    Few studies have investigated the relationship of anthropometric measurements with computed tomography (CT) body fat composition, and even fewer determined if these relationships differ by sex and race. CT scans from 1,851 participants in the population based Multi-Ethnic Study of Atherosclerosis were assessed for visceral and subcutaneous fat areas by semi-automated segmentation of body compartments. Regression models were used to investigate relationships for anthropometry with visceral and subcutaneous fat separately by sex and race/ethnicity. Participants were 50% female, 41% Caucasian, 13% Asian, 21% African American, and 25% Hispanic. For visceral fat, the positive relationship with weight (p = 0.028), waist circumference (panthropometry and underlying adiposity differs by sex and race/ethnicity. When anthropometry is used as a proxy for visceral fat in research, sex-specific models should be used.

  3. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  4. Vector and axial constants of the baryon decuplet

    International Nuclear Information System (INIS)

    Belyaev, V.M.; Blok, B.Y.; Kogan, Y.I.

    1985-01-01

    On the basis of the QCD sum rules for the polarization operator in external axial and vector fields we determine the vector and axial transition constants in the 3/2 + baryon decuplet. We show that the renormalization of the axial constant is due to the interaction of the external axial field with the quark condensate

  5. Nucleon axial form factor from lattice QCD

    International Nuclear Information System (INIS)

    Liu, K.F.; Dong, S.J.; Draper, T.; Wu, J.M.; Wilcox, W.

    1994-01-01

    Results for the isovector axial form factors of the proton from a lattice QCD calculation are presented for both the point-split and local currents. They are obtained on a quenched 16 3 x24 lattice at β=6.0 with Wilson fermions for a range of quark masses from strange to twice the charm mass. For each quark mass, we find that the axial form factor falls off slower than the corresponding proton electric form factor. Results extrapolated to the chiral limit show that the q 2 dependence of the axial form factor agrees quite well with experiment. The axial vector coupling constant g A calculated for the point-split and local currents is 1.20±0.11 and 1.18±0.11. The central values are 4% and 6% smaller than the experimental value of 1.254, respectively. We also consider the large ma correction and renormalization for the axial vector current of heavy quarks

  6. Optimization of residual heat removal pump axial thrust and axial bearing

    International Nuclear Information System (INIS)

    Schubert, F.

    1996-01-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies

  7. Optimization of residual heat removal pump axial thrust and axial bearing

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  8. Wave propagation in axially moving periodic strings

    DEFF Research Database (Denmark)

    Sorokin, Vladislav S.; Thomsen, Jon Juel

    2017-01-01

    The paper deals with analytically studying transverse waves propagation in an axially moving string with periodically modulated cross section. The structure effectively models various relevant technological systems, e.g. belts, thread lines, band saws, etc., and, in particular, roller chain drives...... for diesel engines by capturing both their spatial periodicity and axial motion. The Method of Varying Amplitudes is employed in the analysis. It is shown that the compound wave traveling in the axially moving periodic string comprises many components with different frequencies and wavenumbers....... This is in contrast to non-moving periodic structures, for which all components of the corresponding compound wave feature the same frequency. Due to this "multi-frequency" character of the wave motion, the conventional notion of frequency band-gaps appears to be not applicable for the moving periodic strings. Thus...

  9. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  10. Axial pico turbine - construction and experimental research

    Science.gov (United States)

    Peczkis, G.; Goryca, Z.; Korczak, A.

    2017-08-01

    The paper concerns axial water turbine of power equal to 1 kW. The example of axial water turbine constructional calculations was provided, as well as turbine rotor construction with NACA profile blades. The laboratory test rig designed and built to perform measurements on pico turbine was described. The turbine drove three-phase electrical generator. On the basis of highest efficiency parameters, pico turbine basic characteristics were elaborated. The experimental research results indicated that pico turbine can achieve maximum efficiency close to the values of larger water turbines.

  11. Axial Vircator for Electronic Warfare Applications

    Directory of Open Access Journals (Sweden)

    L. Drazan

    2009-12-01

    Full Text Available This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered by magneto-cumulative generator and in weapons for defense of objects (WDO, it is powered by Marx generator. The possible applications of a vircator in the DEWM area are discussed.

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special ... the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT ...

  13. Positron Emission Tomography - Computed Tomography (PET/CT)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Positron Emission Tomography - Computed Tomography (PET/CT) Positron emission tomography (PET) ... Emission Tomography – Computed Tomography (PET/CT)? What is Positron Emission Tomography – Computed Tomography (PET/CT) Scanning? Positron emission tomography, ...

  14. A pictorial review of atlanto-axial rotatory fixation: Key points for the radiologist

    International Nuclear Information System (INIS)

    Roche, Clare J.; O'Malley, Michael; Dorgan, John C.; Carty, Helen M.

    2001-01-01

    Atlanto-axial rotatory fixation (AARF) is a rare condition which occurs more commonly in children than in adults. The terminology can be confusing and the condition is also known as 'atlanto-axial rotatory subluxation' and 'atlanto-axial rotary dislocation'. Rotatory fixation is the preferred term, however, as in most cases the fixation occurs within the normal range of rotation of the joint. By definition, therefore, the joint is neither subluxed nor dislocated. AARF is a cause of acquired torticollis. Diagnosis can be difficult and is often delayed. The radiologist plays a key role in confirming the diagnosis. The classification system proposed by Fielding in 1977 is most frequently used and will be discussed in detail. Given that this classification system was devised in the days before computed tomography (CT), as well as the fact that combined atlanto-axial and atlanto-occipital rotatory subluxation (AORF) is omitted from the classification, we propose a modification to the classification of this rare but significant disorder. The radiological findings in six cases of AARF will be illustrated, including a case with associated atlanto-occipital subluxation. The pertinent literature is reviewed and a more comprehensive classification system proposed. The imaging approach to diagnosis and the orthopaedic approach to management will be discussed. Roche, C.J. et al. (2001)

  15. A pictorial review of atlanto-axial rotatory fixation: Key points for the radiologist

    Energy Technology Data Exchange (ETDEWEB)

    Roche, Clare J.; O' Malley, Michael; Dorgan, John C.; Carty, Helen M

    2001-12-01

    Atlanto-axial rotatory fixation (AARF) is a rare condition which occurs more commonly in children than in adults. The terminology can be confusing and the condition is also known as 'atlanto-axial rotatory subluxation' and 'atlanto-axial rotary dislocation'. Rotatory fixation is the preferred term, however, as in most cases the fixation occurs within the normal range of rotation of the joint. By definition, therefore, the joint is neither subluxed nor dislocated. AARF is a cause of acquired torticollis. Diagnosis can be difficult and is often delayed. The radiologist plays a key role in confirming the diagnosis. The classification system proposed by Fielding in 1977 is most frequently used and will be discussed in detail. Given that this classification system was devised in the days before computed tomography (CT), as well as the fact that combined atlanto-axial and atlanto-occipital rotatory subluxation (AORF) is omitted from the classification, we propose a modification to the classification of this rare but significant disorder. The radiological findings in six cases of AARF will be illustrated, including a case with associated atlanto-occipital subluxation. The pertinent literature is reviewed and a more comprehensive classification system proposed. The imaging approach to diagnosis and the orthopaedic approach to management will be discussed. Roche, C.J. et al. (2001)

  16. No evidence for a role of the serotonin 4 receptor in five-factor personality traits: A positron emission tomography brain study.

    Science.gov (United States)

    Stenbæk, Dea Siggaard; Dam, Vibeke Høyrup; Fisher, Patrick MacDonald; Hansen, Nanna; Hjordt, Liv Vadskjær; Frokjaer, Vibe Gedsoe

    2017-01-01

    Serotonin (5-HT) brain architecture appears to be implicated in normal personality traits as supported by genetic associations and studies using molecular brain imaging. However, so far, no studies have addressed potential contributions to variation in normal personality traits from in vivo serotonin 4 receptor (5-HT4R) brain availability, which has recently become possible to image with Positron Emission Tomography (PET). This is particularly relevant since availability of 5-HT4R has been shown to adapt to synaptic levels of 5-HT and thus offers information about serotonergic tone in the healthy brain. In 69 healthy participants (18 females), the associations between personality traits assessed with the five-factor NEO Personality Inventory-Revised (NEO PI-R) and regional cerebral 5-HT4R binding in neocortex, amygdala, hippocampus, and anterior cingulate cortex (ACC) were investigated using linear regression models. The associations between each of the five personality traits and a latent variable construct of global 5-HT4R levels were also evaluated using latent variable structural equation models. We found no significant associations between the five NEO personality traits and regional 5-HT4R binding (all p-values > .17) or the latent construct of global 5-HT4R levels (all p-values > .37). Our findings indicate that NEO personality traits and 5-HT4R are not related in healthy participants. Under the assumption that global 5-HT4R levels index 5-HT tone, our data also suggest that 5-HT tone per se is not directly implicated in normal personality traits.

  17. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  18. Axial crystals macroscopic symmetry and tensor properties

    Czech Academy of Sciences Publication Activity Database

    Janovec, Václav

    2017-01-01

    Roč. 90, č. 1 (2017), s. 1-10 ISSN 0141-1594 Institutional support: RVO:68378271 Keywords : axial * polar * pseudopolar * chiral * enantiomorphism * optical activity Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.060, year: 2016

  19. Optimisation of efficiency of axial fans

    NARCIS (Netherlands)

    Kruyt, Nicolaas P.; Pennings, P.C.; Faasen, R.

    2014-01-01

    A three-stage research project has been executed to develop ducted axial-fans with increased efficiency. In the first stage a design method has been developed in which various conflicting design criteria can be incorporated. Based on this design method, an optimised design has been determined

  20. The design of axial shaftless pump

    Science.gov (United States)

    Schmirler, Michal; Netrebska, Hana

    The axial shaftless pump with a rotary casing has been proposed. The pump is unique in its small space requirements and the ability to draw a liquid with a high content of impurities and fibers. Modern motor with an external commutation was used to propel the pump rotor. The pump can be used for both pumping of liquids and marine propulsion.

  1. VERY SLOW SPEED AXIAL MOTION RELUCTANCE MOTOR

    African Journals Online (AJOL)

    Dr Obe

    1984-09-01

    Sep 1, 1984 ... VERY SLOW SPEED AXIAL MOTION RELUCTANCE MOTOR by. L. A. Agu. Electrical Engineering Department. University of Nigeria, Nsukka. ABSTRACT. This paper presents the scheme for a very slow speed linear machine which uses conventional laminations and with which speeds of the same low.

  2. Aryabha~ and Axial Rotation of Earth

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 4. Aryabhata and Axial Rotation of Earth - Naksatra Dina (the Sidereal Day). Amartya Kumar Dutta. General Article Volume 11 Issue 4 April 2006 pp 56-74. Fulltext. Click here to view fulltext PDF. Permanent link:

  3. Aryabhala and Axial Rotation of Earth

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 3. Aryabhata and Axial Rotation of Earth - Khagola (The Celestial Sphere). Amartya Kumar Dutta. General Article Volume 11 Issue 3 March 2006 pp 51-68. Fulltext. Click here to view fulltext PDF. Permanent link:

  4. The axial polarizability of nucleons and nuclei

    International Nuclear Information System (INIS)

    Ericson, M.; Figureau, A.

    1981-02-01

    The part of the static nuclear axial polarizability arising from the nucleonic excitations is derived from the low energy expansion of the πN amplitude. It is shown that the contribution of the Δ intermediate state, though dominant, does not saturate the nucleonic response. A similar effect, though more pronounced, is known to occur for the magnetic susceptibility

  5. Excitation modes in non-axial nuclei

    International Nuclear Information System (INIS)

    Leviatan, A.; Ginnochio, J.N.

    1990-01-01

    Excitation modes of non-axial quadrupole shapes are investigated in the framework of interacting boson models. Both γ-unstable and γ-rigid nuclear shapes are considered for systems with one type of boson as well as with proton-neutron bosons. 6 refs

  6. Excitation modes in non-axial nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Leviatan, A.; Ginnochio, J.N.

    1990-01-01

    Excitation modes of non-axial quadrupole shapes are investigated in the framework of interacting boson models. Both {gamma}-unstable and {gamma}-rigid nuclear shapes are considered for systems with one type of boson as well as with proton-neutron bosons. 6 refs.

  7. AERODYNAMIC DESIGN OF HIGH PRESSRE AXIAL FAN

    Directory of Open Access Journals (Sweden)

    Y. A. Ryzhov

    2014-01-01

    Full Text Available The paper presents the results of numerical studies of flow in a high axial fan of H-2, the geometric parameters are carefully designed by the author. The coefficients of performance, the total pressure, efficiency and capacity. Shows the benefits of fan of H-2 on several other fans, expressed in increased efficiency with equal dimensions and angles of blade setting.

  8. Co-axial, high energy gamma generator

    Science.gov (United States)

    Reijonen, Jani Petteri [Princeton, NJ; Gicquel, Frederic [Pennington, NJ

    2011-08-16

    A gamma ray generator includes an ion source in a first chamber. A second chamber is configured co-axially around the first chamber at a lower second pressure. Co-axially arranged plasma apertures separate the two chambers and provide for restricted passage of ions and gas from the first to the second chamber. The second chamber is formed by a puller electrode having at least one long channel aperture to draw ions from the first chamber when the puller electrode is subject to an appropriate applied potential. A plurality of electrodes rings in the third chamber in third pressure co-axially surround the puller electrode and have at least one channel corresponding to the at least one puller electrode aperture and plasma aperture. The electrode rings increase the energy of the ions to a selected energy in stages in passing between successive pairs of the electrodes by application of an accelerating voltage to the successive pairs of accelerator electrodes. A target disposed co-axially around the plurality of electrodes receives the beam of accelerated ions, producing gamma rays.

  9. Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study.

    Science.gov (United States)

    Hausleiter, Jörg; Meyer, Tanja S; Martuscelli, Eugenio; Spagnolo, Pietro; Yamamoto, Hiroaki; Carrascosa, Patricia; Anger, Thomas; Lehmkuhl, Lukas; Alkadhi, Hatem; Martinoff, Stefan; Hadamitzky, Martin; Hein, Franziska; Bischoff, Bernhard; Kuse, Miriam; Schömig, Albert; Achenbach, Stephan

    2012-05-01

    The purpose of this study was to evaluate image quality and radiation dose using a prospectively electrocardiogram (ECG)-triggered axial scan protocol compared with standard retrospective ECG-gated helical scanning for coronary computed tomography angiography. Concerns have been raised regarding radiation exposure during coronary computed tomography angiography. Although the use of prospectively ECG-triggered axial scan protocols may effectively lower radiation dose compared with helical scanning, it is unknown whether image quality is maintained in a clinical setting. In a prospective, multicenter, multivendor trial, 400 patients with low and stable heart rates were randomized to either an axial or a helical coronary computed tomography angiography scan protocol. The primary endpoint was to demonstrate noninferiority in image quality with the axial scan protocol, which was assessed on a 4-point scale (1 = nondiagnostic, 4 = excellent image quality). Secondary endpoints included radiation dose and the rate of downstream testing during 30-day follow-up. Image quality in patients scanned with the axial scan protocol (score 3.36 ± 0.59) was not inferior compared with helical scan protocols (3.37 ± 0.59) (p for noninferiority <0.004). Axial scanning was associated with a 69% reduction in radiation exposure (dose-length product [estimated effective dose] 252 ± 147 mGy · cm [3.5 ± 2.1 mSv] vs. 802 ± 419 mGy · cm [11.2 ± 5.9 mSv] for axial vs. helical scan protocols, p < 0.001). The rate of downstream testing did not differ (13.8% vs. 15.9% for axial vs. helical scan protocols, p = 0.555). In patients with stable and low heart rates, the prospectively ECG-triggered axial scan protocol maintained image quality but reduced radiation exposure by 69% compared with helical scanning. Axial computed tomography data acquisition should be strongly recommended in suitable patients to avoid unnecessarily high radiation exposure. Copyright © 2012 American College of

  10. Examination of forensic entomology evidence using computed tomography scanning: case studies and refinement of techniques for estimating maggot mass volumes in bodies.

    Science.gov (United States)

    Johnson, Aidan; Archer, Melanie; Leigh-Shaw, Lyndie; Pais, Mike; O'Donnell, Chris; Wallman, James

    2012-09-01

    A new technique has recently been developed for estimating the volume of maggot masses on deceased persons using post-mortem CT scans. This allows volume to be measured non-invasively and factored into maggot mass temperature calculations for both casework and research. Examination of admission scans also allows exploration of entomological evidence in anatomical areas not usually exposed by autopsy (e.g. nasal cavities and facial sinuses), and before autopsy disrupts the maggot distribution on a body. This paper expands on work already completed by providing the x-ray attenuation coefficient by way of Hounsfield unit (HU) values for various maggot species, maggot masses and human tissue adjacent to masses. Specifically, this study looked at the HU values for four forensically important blowfly larvae: Lucilia cuprina, L. sericata, Calliphora stygia and C. vicina. The Calliphora species had significantly lower HU values than the Lucilia species. This might be explained by histological analysis, which revealed a non-significant trend, suggesting that Calliphora maggots have a higher fat content than the Lucilia maggots. It is apparent that the variation in the x-ray attenuation coefficient usually precludes its use as a tool for delineating the maggot mass from human tissue and that morphology is the dominant method for delineating a mass. This paper also includes three case studies, which reveal different applications for interpreting entomological evidence using post-mortem CT scans.

  11. Axial movements are relatively preserved with respect to limb movements in aphasic patients.

    Science.gov (United States)

    Hanlon, R E; Mattson, D; Demery, J A; Dromerick, A W

    1998-12-01

    Apraxia is commonly manifested during the acute stage following left hemisphere cerebrovascular accident and typically co-occurs with aphasia. We examined 30 acute stroke patients with aphasia and apraxia in order to determine if such patients show evidence of preservation of selective subclasses of movements. Although Geschwind noted the preservation of axial movements to command in aphasic apraxic patients, his views were subsequently refuted. However, we found that aphasic apraxic patients of varying degrees of severity, including patients with global aphasia, showed relative preservation of axial movements to command and imitation. Theoretical interpretations and implications for acute neurologic rehabilitation are discussed.

  12. The space-time outside a source of gravitational radiation: the axially symmetric null fluid

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, L. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Universidad de Salamanca, Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain); Di Prisco, A. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Ospino, J. [Universidad de Salamanca, Departamento de Matematica Aplicada and Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain)

    2016-11-15

    We carry out a study of the exterior of an axially and reflection symmetric source of gravitational radiation. The exterior of such a source is filled with a null fluid produced by the dissipative processes inherent to the emission of gravitational radiation, thereby representing a generalization of the Vaidya metric for axially and reflection symmetric space-times. The role of the vorticity, and its relationship with the presence of gravitational radiation is put in evidence. The spherically symmetric case (Vaidya) is, asymptotically, recovered within the context of the 1 + 3 formalism. (orig.)

  13. The atlanto-axial joint: Physiological range of rotation on MRI and CT

    Energy Technology Data Exchange (ETDEWEB)

    Roche, Clare J.; King, Susan J.; Dangerfield, Peter H.; Carty, Helen M

    2002-02-01

    AIMS: To measure the range of rotation and determine the instantaneous axis of rotation of the atlanto-axial joint in healthy volunteers using magnetic resonance imaging (MRI) and to highlight the appearances of the rotated atlanto-axial joint on computed tomography (CT) and MRI. MATERIALS AND METHODS: Twenty-eight healthy volunteers were examined using MRI during maximal head rotation. In addition, an anatomical specimen of the atlanto-axial joint, fixed in varying degrees of rotation, was imaged using CT. RESULTS: At the extremes of physiological rotation in healthy subjects there is striking but incomplete loss of contact between the articular surfaces of the atlas (C1) and the axis (C2). The range of rotation to the right was 20-48{center_dot}5 degree sign (mean 32{center_dot}4 degree sign ) and to the left was 13-52{center_dot}75 degree sign (mean 34{center_dot}2 degree sign ). There was no significant difference between rotation to the right and left (P = 0{center_dot}455). Total rotation was 45-88{center_dot}5 degree sign (mean 69{center_dot}25 degree sign ). The instantaneous axis of rotation was located within the odontoid peg. CONCLUSION: There is a wide range of atlanto-axial rotation in normal subjects. The instantaneous axis of rotation lies within the odontoid peg. The appearances of the rotated atlanto-axial joint are striking and may be misinterpreted as subluxation. Roche, C.J. et al. (2002)

  14. Review of Axial Burnup Distribution Considerations for Burnup Credit Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, J.C.; DeHart, M.D.

    2000-03-01

    This report attempts to summarize and consolidate the existing knowledge on axial burnup distribution issues that are important to burnup credit criticality safety calculations. Recently released Nuclear Regulatory Commission (NRC) staff guidance permits limited burnup credit, and thus, has prompted resolution of the axial burnup distribution issue. The reactivity difference between the neutron multiplication factor (keff) calculated with explicit representation of the axial burnup distribution and keff calculated assuming a uniform axial burnup is referred to as the ``end effect.'' This end effect is shown to be dependent on many factors, including the axial-burnup profile, total accumulated burnup, cooling time, initial enrichment, assembly design, and the isotopics considered (i.e., actinide-only or actinides plus fission products). Axial modeling studies, efforts related to the development of axial-profile databases, and the determination of bounding axial profiles are also discussed. Finally, areas that could benefit from further efforts are identified.

  15. Review of Axial Burnup Distribution Considerations for Burnup Credit Calculations

    International Nuclear Information System (INIS)

    Wagner, J.C.; DeHart, M.D.

    2000-01-01

    This report attempts to summarize and consolidate the existing knowledge on axial burnup distribution issues that are important to burnup credit criticality safety calculations. Recently released Nuclear Regulatory Commission (NRC) staff guidance permits limited burnup credit, and thus, has prompted resolution of the axial burnup distribution issue. The reactivity difference between the neutron multiplication factor (keff) calculated with explicit representation of the axial burnup distribution and keff calculated assuming a uniform axial burnup is referred to as the ''end effect.'' This end effect is shown to be dependent on many factors, including the axial-burnup profile, total accumulated burnup, cooling time, initial enrichment, assembly design, and the isotopics considered (i.e., actinide-only or actinides plus fission products). Axial modeling studies, efforts related to the development of axial-profile databases, and the determination of bounding axial profiles are also discussed. Finally, areas that could benefit from further efforts are identified

  16. Piping inspection carriage having axially displaceable sensor

    Science.gov (United States)

    Zollinger, W.T.; Treanor, R.C.

    1994-12-06

    A pipe inspection instrument carriage is described for use with a pipe crawler for performing internal inspections of piping surfaces. The carriage has a front leg assembly, a rear leg assembly and a central support connecting the two assemblies and for mounting an instrument arm having inspection instruments. The instrument arm has a Y-arm mounted distally thereon for axially aligning the inspection instrumentation and a mounting block, a linear actuator and axial movement arm for extending the inspection instruments radially outward to operably position the inspection instruments on the piping interior. Also, the carriage has a rotation motor and gear assembly for rotating the central support and the front leg assembly with respect to the rear leg assembly so that the inspection instruments azimuthally scan the piping interior. The instrument carriage allows performance of all piping inspection operations with a minimum of moving parts, thus decreasing the likelihood of performance failure. 4 figures.

  17. Ventajas de los motores de flujo axial

    Directory of Open Access Journals (Sweden)

    Alberto M Basanta Otero

    2011-03-01

    Full Text Available Es importante conocer sobre una familia de motores que a diferencia de los convencionales o tradicionales no presentanun flujo rotatorio radial, denominados motores de flujo axial. Dichos motores presentan altos valores de par motriz abajas velocidades, una alta eficiencia y alta densidad de potencia. Este trabajo constituye un breve análisis dealgunos motores de la referencia bibliográfica.  Is important to know about a family of motors that at difference whit the traditional, don't have a rotator radial flux,called, axial flux motors. These motors have high torque for low speed, high efficiency and high power density. Thiswork is a brief analysis of several motors of the bibliographic references.

  18. Cross-flow filtration and axial filtration

    International Nuclear Information System (INIS)

    Kraus, K.A.

    1974-01-01

    Two relatively novel alternative solid-liquid-separation techniques of filtration are discussed. In cross-flow filtration, the feed is pumped past the filtering surface. While in axial filtration the filter, mounted on a rotor, is moved with respect to the feed. While large-scale application of the axial filter is still in doubt, it permits with little expenditure of time and money, duplication of many hydrodynamic aspects of cross-flow filtration for fine-particle handling problems. The technique has been applied to municipal wastes, low-level radioactive waste treatment plant, lead removal from industrial wastes, removal of pulp-mill contaminants, textile-mill wastes, and pretreatment of saline waters by lime-soda process in preparation for hyperfiltration. Economics and energy requirements are also discussed

  19. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  20. Axial pattern skin flaps in cats.

    Science.gov (United States)

    Remedios, A M; Bauer, M S; Bowen, C V; Fowler, J D

    1991-01-01

    The major direct cutaneous vessels identified in the cat include the omocervical, thoracodorsal, deep circumflex iliac, and caudal superficial epigastric arteries. Axial pattern skin flaps based on the thoracodorsal and caudal superficial epigastric arteries have been developed in cats. Rotation of these flaps as islands allows skin coverage to the carpus and metatarsus, respectively. The thoracodorsal and caudal superficial epigastric flaps provide a practical, one-step option in the reconstruction of large skin defects involving the distal extremities of cats.

  1. Atlanto-axial subluxation: a case report

    OpenAIRE

    Thurlow, Robert D

    1988-01-01

    One of the causes of death in rheumatoid patients is cord compression following atlanto-axial subluxation. Dislocations in the cervical spine are common with patients who have rheumatoid arthritis. Anterior subluxation occurs in up to 35%, followed by vertical subluxation in 22.2%, lateral subluxation in 20.6% and rarely posterior subluxation. A case report is presented to illustrate such a complication.

  2. Axial flux permanent magnet brushless machines

    CERN Document Server

    Gieras, Jacek F; Kamper, Maarten J

    2008-01-01

    Axial Flux Permanent Magnet (AFPM) brushless machines are modern electrical machines with a lot of advantages over their conventional counterparts. They are being increasingly used in consumer electronics, public life, instrumentation and automation system, clinical engineering, industrial electromechanical drives, automobile manufacturing industry, electric and hybrid electric vehicles, marine vessels and toys. They are also used in more electric aircrafts and many other applications on larger scale. New applications have also emerged in distributed generation systems (wind turbine generators

  3. Cervical Spine Axial Rotation Goniometer Design

    OpenAIRE

    Emin Ulaş Erdem; Filiz Can

    2012-01-01

    To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera). With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measureme...

  4. Axial gravity, massless fermions and trace anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Bonora, L. [International School for Advanced Studies (SISSA), Trieste (Italy); KEK, Tsukuba (Japan). KEK Theory Center; INFN, Sezione di Trieste (Italy); Cvitan, M.; Giaccari, S.; Stemberga, T. [Zagreb Univ. (Croatia). Dept. of Physics; Prester, P.D. [Rijeka Univ. (Croatia). Dept. of Physics; Pereira, A.D. [UERJ-Univ. Estadual do Rio de Janeiro (Brazil). Dept. de Fisica Teorica; UFF-Univ. Federal Fluminense, Niteroi (Brazil). Inst. de Fisica

    2017-08-15

    This article deals with two main topics. One is odd parity trace anomalies in Weyl fermion theories in a 4d curved background, the second is the introduction of axial gravity. The motivation for reconsidering the former is to clarify the theoretical background underlying the approach and complete the calculation of the anomaly. The reference is in particular to the difference between Weyl and massless Majorana fermions and to the possible contributions from tadpole and seagull terms in the Feynman diagram approach. A first, basic, result of this paper is that a more thorough treatment, taking account of such additional terms and using dimensional regularization, confirms the earlier result. The introduction of an axial symmetric tensor besides the usual gravitational metric is instrumental to a different derivation of the same result using Dirac fermions, which are coupled not only to the usual metric but also to the additional axial tensor. The action of Majorana and Weyl fermions can be obtained in two different limits of such a general configuration. The results obtained in this way confirm the previously obtained ones. (orig.)

  5. Axial polarizability and weak currents in nuclei

    International Nuclear Information System (INIS)

    Ericson, M.

    1977-01-01

    The weak interaction nucleonic coupling constants in nuclei are modified by the presence of the neighbouring nucleons. One type of modification is due to the virtual excitation of the isobars through meson exchange. The influence of the isobars is described by means of the nuclear axial polarizability coefficient. This polarizability is known; it is linked to the p-wave πN scattering volume. A relation is derived between the axial nuclear current and the pion field which incorporates the polarizability effects. This relation has an electromagnetic analogue. It is then possible to derive the axial and pseudoscalar coupling constants from a knowledge of the pion field. This field in turn obeys a Klein-Gordon equation which has to include the isobaric excitations. The propagation of the pion field is similar to that of an electromagnetic wave in a dielectric medium. The strong interaction coupling constant is shown to be renormalized in nuclei by the effect of the various types of correlations. (author)

  6. Dynamic control of knee axial deformities

    Directory of Open Access Journals (Sweden)

    E. E. Malyshev

    2013-01-01

    Full Text Available The authors have evaluated the clinical examination of the patients with axial malalignments in the knee by the original method and device which was named varovalgometer. The measurements were conducted by tension of the cord through the spina iliaca anterior superior and the middle of the lower pole of patella. The deviation of the center of the ankle estimated by metal ruler which was positioned perpendicular to the lower leg axis on the level of the ankle joint line. The results of comparison of our method and computer navigation in 53 patients during the TKA show no statistically significant varieties but they differ by average 5° of valgus in clinical examination in comparison with mechanical axis which was identified by computer navigation. The dynamic control of axial malalignment can be used in clinical practice for estimation of the results of treatment of pathology with axial deformities in the knee; for the control of reduction and secondary displacement of the fractures around the knee; for assessment of instability; in planning of correctional osteotomies and intraoperative control of deformity correction; for estimation of Q angle in subluxation and recurrent dislocation of patella; in planning of TKA; during the growth of child it allows to assess the progression of deformity.

  7. Respiratory effects of transient axial acceleration.

    Science.gov (United States)

    Loring, S H; Lee, H T; Butler, J P

    2001-06-01

    Whereas gravity has an inspiratory effect in upright subjects, transient upward acceleration is reported to have an expiratory effect. To explore the respiratory effects of transient axial accelerations, we measured axial acceleration at the head and transrespiratory pressure or airflow in five subjects as they were dropped or lifted on a platform. For the first 100 ms, upward acceleration caused a decrease in mouth pressure and inspiratory flow, and downward acceleration caused the opposite. We also simulated these experimental observations by using a computational model of a passive respiratory system based on anatomical data and normal respiratory characteristics. After 100 ms, respiratory airflow in our subjects became highly variable, no longer varying with acceleration. Electromyograms of thoracic and abdominal respiratory muscles showed bursts of activity beginning 40-125 ms after acceleration, suggesting reflex responses responsible for subsequent flow variability. We conclude that, in relaxed subjects, transient upward axial acceleration causes inspiratory airflow and downward acceleration causes expiratory airflow, but that after ~100 ms, reflex activation of respiratory musculature largely determines airflow.

  8. Can axial pain be helpful to determine surgical level in the multilevel cervical radiculopathy?

    Science.gov (United States)

    Suh, Bo-Kyung; You, Ki Han; Park, Moon Soo

    2017-01-01

    Spine surgeons are required to differentiate symptomatic cervical disc herniation with asymptomatic radiographic herniation. Although the dermatomal sensory dysfunction of upper extremity is the most important clue, axial pain including cervicogenic headache and parascapular pain may be helpful to find surgical target level. However, there is no review article about the axial pain originated from cervical spondylotic radiculopathy and relieved by surgical decompression. The purpose is to review the literatures about the axial pain, which can be utilized in determining target level to be decompressed in the patients with cervical radiculopathy at multiple levels. Cervicogenic headaches of suboccipital headaches, retro-orbital pain, retro-auricular pain, or temporal pain may be associated with C2, C3, and C4 radiculopathies. The pain around scapula may be associated with C5, C6, C7, and C8 radiculopathies. However, there is insufficient evidence to make recommendations for the use in clinical practice because they did not evaluate sensitivity and specificity.

  9. Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Segars, W. P.; Rybicki, K.; Norris, Hannah; Samei, E.; Frush, D.

    2014-01-01

    Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r 2 = 0.382, mean r 2 = 0.236). Similar trends were found for organ midpoint versus height (max r 2 = 0.439, mean r 2 = 0.200) and for organ volume versus height (max r 2 = 0.410, mean r 2 = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r 2 -values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r 2 = 0.842, mean r 2 = 0.790; max r 2 = 0.949, mean r 2 = 0.894; and max r 2 = 0.870, mean r 2 = 0.847, respectively). Moderate linear correlations were also observed for organ axial width versus height (max r 2 = 0.772, mean r 2 = 0.562) and for organ

  10. Cranial computerized tomography in children suffering from acute leukemia

    International Nuclear Information System (INIS)

    Metz, O.

    1981-01-01

    Cranial computerized (axial) tomography permits a more complete neurologic supervision of children with acute leukemia and a better knowledge of the frequency and varieties of cerebral complications in leukemia. Endocranial complications in acute leukemia are essentially infiltrative, hemorrhagic, infectious or iatrogenic. Cranial computerized tomography can demonstrate cerebral changes in meningeal leukemia, hemorrhages, calcifications, brain atrophy or leukencephalopathy. The preliminary results of cranial computerized tomography in childhood leukemia suggest that the iatrogenic main lesion of the brain due to combined radiation-chemotherapy is atrophy whereas that of the intrathecal cytostatic therapy is demyelination. Accurate diagnostics and control of possible cerebral complications in therapy of leukemia is essentially for appropriate therapeutic management. For that cranial computerized tomography is the best method to a effective supervision of the brain. (author)

  11. Intrinsic carpal ligaments on MR and multidetector CT arthrography: comparison of axial and axial oblique planes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Ng, Alex W.H.; Law, Eric K.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong (China); Tse, W.L.; Wong, Clara W.Y.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince Of Wales Hospital, Hong Kong (China)

    2017-03-15

    To compare axial and oblique axial planes on MR arthrography (MRA) and multidetector CT arthrography (CTA) to evaluate dorsal and volar parts of scapholunate (SLIL) and lunotriquetral interosseous (LTIL) ligaments. Nine cadaveric wrists of five male subjects were studied. The visibility of dorsal and volar parts of the SLIL and LTIL was graded semi-quantitatively (good, intermediate, poor) on MRA and CTA. The presence of a ligament tear was determined on arthrosocopy and sensitivity, specificity and accuracy of tear detection were calculated. Oblique axial imaging was particularly useful for delineating dorsal and volar parts of the LTIL on MRA with overall 'good' visibility increased from 11 % to 78 %. The accuracy of MRA and CTA in revealing SLIL and LTIL tear was higher using the oblique axial plane. The overall accuracy for detecting SLIL tear on CTA improved from 94 % to 100 % and from 89 % to 94 % on MRA; the overall accuracy of detecting LTIL tear on CTA improved from 89 % to 100 % and from 72 % to 89 % on MRA Oblique axial imaging during CT and MR arthrography improves detection of tears in the dorsal and volar parts of both SLIL and LTIL. (orig.)

  12. Cone-Beam Computed Tomography and Interdisciplinary Dentofacial Therapy: An American Academy of Periodontology Best Evidence Review Focusing on Risk Assessment of the Dentoalveolar Bone Changes Influenced by Tooth Movement.

    Science.gov (United States)

    Mandelaris, George A; Neiva, Rodrigo; Chambrone, Leandro

    2017-10-01

    The aim of this systematic review is to evaluate whether cone-beam computed tomography (CBCT) imaging can be used to assess dentoalveolar anatomy critical to the periodontist when determining risk assessment for patients undergoing orthodontic therapy using fixed or removable appliances. Both observational and interventional trials reporting on the use of CBCT imaging assessing the impact of orthodontic/dentofacial orthopedic treatment on periodontal tissues (i.e., alveolar bone) were included. Changes in the alveolar bone thickness and height around natural teeth as well as treatment costs were evaluated. MEDLINE (via PubMed) and EMBASE databases were searched for articles published in the English language, up to and including July 2016, and extracted data were organized into evidence tables. Thirteen studies were included in this systematic review describing the positive or deleterious changes on the alveolar bone surrounding natural teeth undergoing orthodontic tooth movement or influenced by orthopedic forces through fixed appliances. Clinical recommendation summaries presenting the strengths and weaknesses of the evidence in terms of benefits and harms were generated. CBCT imaging can improve the periodontal diagnostic acumen regarding alveolar bone alterations influenced by orthodontic tooth movement and can help determine risk assessment prior to such intervention. Clinicians are also better informed to determine risk assessment and develop preventative or plan interceptive periodontal augmentation (soft tissue and/or bone augmentation) therapies for patients undergoing orthodontic tooth movement. These considerations are recognized as being especially critical for treatment approaches in patients where buccal tooth movement (expansion) is planned in the anterior mandible or involving the maxillary premolars.

  13. Estudo de caso de oferta induzindo a demanda: o caso da oferta de exames de imagem (tomografia axial computadorizada e ressonância magnética na Unimed-Manaus Case study of supply induced demand: the case of provision of imaging scans (computed tomography and magnetic resonance at Unimed-Manaus

    Directory of Open Access Journals (Sweden)

    Edson de Oliveira Andrade

    2011-04-01

    Full Text Available OBJETIVO: Apresentar a experiência de uma operadora de plano de saúde (Unimed-Manaus na cidade de Manaus, Estado do Amazonas, com o credenciamento de serviços de imagem e a indução de demanda pela oferta dos novos serviços (Lei de Roemer. MÉTODOS: Trata-se de uma pesquisa de caráter retrospectivo, com estudo de série temporal, abordando o período de janeiro de 1998 a junho de 2004, lapso de tempo em que ocorreu a implantação dos serviços de tomografia computadorizada e da ressonância magnética no âmbito dos serviços oferecidos por aquele plano de saúde. A análise estatística consistiu em uma parte descritiva e uma inferencial, sendo esta última utilizando teste paramétrico de média (teste t de Student e ANOVA e o teste de correlação de Pearson. Foi adotado um alfa de 5% e um intervalo de confiança de 95%. RESULTADOS: Foi possível identificar na Unimed-Manaus que a oferta de novos serviços de imagem foi capaz de, por si só, gerar um aumento da demanda do serviço caracterizando o fenômeno descrito por Roemer. CONCLUSÃO: Os resultados deste trabalho ressaltam a necessidade de se estar atento ao fato de que a oferta de novos serviços no setor da saúde poderá acarretar, por si só, um aumento de sua utilização sem que haja uma demanda real.OBJECTIVE: To present the experience of a health plan operator (Unimed-Manaus in Manaus, Amazonas, Brazil, with the accreditation of imaging services and the demand induced by the supply of new services (Roemer's Law. METHODS: This is a retrospective work studying a time series covering the period from January 1998 to June 2004, in which the computed tomography and the magnetic resonance imaging services were implemented as part of the services offered by that health plan operator. Statistical analysis consisted of a descriptive and an inferential part, with the latter using a mean parametric test (Student T-test and ANOVA and the Pearson correlation test. A 5% alpha and a 95

  14. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Science.gov (United States)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  15. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  16. Volar morphology of the distal radius in axial planes: a quantitative analysis.

    Science.gov (United States)

    Oura, Keiichiro; Oka, Kunihiro; Kawanishi, Yohei; Sugamoto, Kazuomi; Yoshikawa, Hideki; Murase, Tsuyoshi

    2015-04-01

    To investigate the cause of rupture of the flexor pollicis longus (FPL) after volar plate fixation of distal radius fractures, previous studies have examined the shape of the distal radius in the sagittal plane or in the lateral view. However, there are no reports on the anatomical shape of the volar surface concavity of the distal radius in the axial plane. We hypothesized that this concavity might contribute to the mismatch between the plate and the surface of the radius. To test this hypothesis, we constructed three-dimensional models of the radius and FPL based on computed tomography scans of 70 normal forearms. We analyzed axial cross-sectional views with 2 mm intervals. In all cases, the volar surface of the distal radius was concave in the axial plane. The concavity depth was maximum at 6 mm proximal to the palmar edge of the lunate fossa and progressively decreased toward the proximal radius. FPL was closest to the radius at 2 mm proximal to the palmar edge of the lunate fossa. The volar surface of the distal radius was externally rotated from proximal to distal. These results may help to develop new implants which fit better to the radius and decrease tendon irritation. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Three-dimensional computed tomography of the acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S.; Muner, G.; Pozzi Mucelli, F.; Pozzi Mucelli, M.; Marotti, F.; Dalla Palma, L.

    1986-08-01

    Acetabular fractures represent a complex variety that are classified in different types. Conventional radiology is often inadequate to demonstrate and classify the fractures. Computed tomography (CT) has already been shown to be superior in this field. A further advantage of CT is represented by the recent availability of three-dimensional (3D) images that are realized from axial CT scans by means of a new software. The Authors report the applications of this new software to the study of the normal acetabulum and in patients with fractures. 3D images allows an effective demonstration of the fracture, its irradiation and the dislocation of bone fragments. The information is contained in one or few images rather than many axial images. Therefore the role of 3D images may be considered complementary to axial CT scans.

  18. Advances of optical coherence tomography in myopia and pathologic myopia

    OpenAIRE

    Ng, D S C; Cheung, C Y L; Luk, F O; Mohamed, S; Brelen, M E; Yam, J C S; Tsang, C W; Lai, T Y Y

    2016-01-01

    The natural course of high-axial myopia is variable and the development of pathologic myopia is not fully understood. Advancements in optical coherence tomography (OCT) technology have revealed peculiar intraocular structures in highly myopic eyes and unprecedented pathologies that cause visual impairment. New OCT findings include posterior precortical vitreous pocket and precursor stages of posterior vitreous detachment; peripapillary intrachoroidal cavitation; morphological patterns of scle...

  19. QCD plasma parameters in axial gauge

    Energy Technology Data Exchange (ETDEWEB)

    Nachbagauer, H. (Technische Univ., Vienna (Austria). Inst. fuer Theoretische Physik)

    1992-11-01

    Within the framework of imaginary time formalism we investigate the structure of the gluon polarization tensor and relate its structure functions to the dispersion relation of plasma eigenmodes. To one loop order, we calculate the transversal structure function to leading order in the high temperature expansion as well as the first subleading order contribution in the long wavelength limit. The result is used to express the dynamical mass and the damping constant for transversal plasma eigenmodes. The aim of our present paper is a systematic discussion of the gauge fixing vector dependence of the damping constant. In the limit of temporal axial gauge we encounter a negative damping constant contradicting previous results. (orig.).

  20. QCD plasma parameters in axial gauge

    Science.gov (United States)

    Nachbagauer, Herbert

    1992-09-01

    Within the framework of imaginary time formalism we investigate the structure of the gluon polarization tensor and relate its structure functions to the dispersion relation of plasma eigenmodes. To one loop order, we calculate the transversal structure function to leading order in the high temperature expansion as well as the first subleading order contribution in the long wavelength limit. The result is used to express the dynamical mass and the damping constant for transversal plasma eigenmodes. The aim of our present paper is a systematic discussion of the gauge fixing vector dependence of the damping constant. In the limit of temporal axial gauge we encounter a negative damping constant contradicting previous results.

  1. Disordered axial movement in Parkinson's disease.

    OpenAIRE

    Steiger, M J; Thompson, P D; Marsden, C D

    1996-01-01

    Axial motor impairments are a common cause of disability in patients with Parkinson's disease, become more prominent with longer disease duration, and have been said to be less responsive to levodopa replacement therapy. The ability to turn in bed while lying supine before and after dopaminergic stimulation was studied in a group of 36 patients with Parkinson's disease; 23 were in Hoehn and Yahr stages 3-5 when "off", and 13 were in stages 1-2. Turning was also compared with postural stabilit...

  2. Water ingestion into jet engine axial compressors

    Science.gov (United States)

    Tsuchiya, T.; Murthy, S. N. B.

    1982-01-01

    An axial flow compressor has been tested with water droplet ingestion under a variety of conditions. The results illustrate the manner in which the compressor pressure ratio, efficiency and surging characteristics are affected. A model for estimating the performance of a compressor during water ingestion has been developed and the predictions obtained compare favorably with the test results. It is then shown that with respect to five droplet-associated nonlinearly-interacting processes (namely, droplet-blade interactions, blade performance changes, centrifugal action, heat and mass transfer processes and droplet break-up), the initial water content and centrifugal action play the most dominant roles.

  3. Ankylosing Spondylitis versus Nonradiographic Axial Spondyloarthritis

    DEFF Research Database (Denmark)

    Glintborg, Bente; Sørensen, Inge J; Østergaard, Mikkel

    2017-01-01

    OBJECTIVE: To compare baseline disease activity and treatment effectiveness in biologic-naive patients with nonradiographic axial spondyloarthritis (nr-axSpA) and ankylosing spondylitis (AS) who initiate tumor necrosis factor inhibitor (TNFi) treatment and to study the role of potential confounders....../disease duration/TNFi-type/smoking/baseline disease activity) on TNFi adherence and response [e.g., Bath Ankylosing Spondylitis Activity Index (BASDAI) 50%/20 mm]. RESULTS: The study included 1250 TNFi-naive patients with axSpA (29% nr-axSpA, 50% AS, 21% lacked radiographs of sacroiliac joints). Patients...

  4. Cervical Spine Axial Rotation Goniometer Design

    Directory of Open Access Journals (Sweden)

    Emin Ulaş Erdem

    2012-06-01

    Full Text Available To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera. With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measurement of "joint position sense" which is recently has rising interest in researches can be made practically with this goniometer.

  5. Imaging of basal cell carcinoma by high-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, M A L M; Norrenberg, S; Jemec, G B E

    2012-01-01

    With the continued development of noninvasive therapies for basal cell carcinoma (BCC) such as photodynamic therapy and immune therapies, noninvasive diagnosis and monitoring become increasingly relevant. High-definition optical coherence tomography (HD-OCT) is a high-resolution imaging tool......, with micrometre resolution in both transversal and axial directions, enabling visualization of individual cells up to a depth of around 570 μm, and filling the imaging gap between conventional optical coherence tomography (OCT) and reflectance confocal microscopy (RCM)....

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography ( ... cross-sectional images generated during a CT scan can be reformatted in multiple planes, and can even ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  8. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  9. Spectral and Diffraction Tomography

    OpenAIRE

    Lionheart, William

    2016-01-01

    We discuss several cases of what we call "Rich Tomography" problems in which more data is measured than a scalar for each ray. We give examples of infra red spectral tomography and Bragg edge neutron tomography in which the data is insufficient. For diffraction tomography of strain for polycrystaline materials we give an explicit reconstruction procedure. We go on to describe a way to find six independent rotation axes using Pascal's theorem of projective geometry

  10. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Perfusion of the Head CT Angiography (CTA) Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography ( ...

  12. Axial vessel widening in arborescent monocots.

    Science.gov (United States)

    Petit, Giai; DeClerck, Fabrice A J; Carrer, Marco; Anfodillo, Tommaso

    2014-02-01

    Dicotyledons have evolved a strategy to compensate for the increase in hydraulic resistance to water transport with height growth by widening xylem conduits downwards. In monocots, the accumulation of hydraulic resistance with height should be similar, but the absence of secondary growth represents a strong limitation for the maintenance of xylem hydraulic efficiency during ontogeny. The hydraulic architecture of monocots has been studied but it is unclear how monocots arrange their axial vascular structure during ontogeny to compensate for increases in height. We measured the vessel lumina and estimated the hydraulic diameter (Dh) at different heights along the stem of two arborescent monocots, Bactris gasipaes (Kunth) and Guadua angustifolia (Kunth). For the former, we also estimated the variation in Dh along the leaf rachis. Hydraulic diameter increased basally from the stem apex to the base with a scaling exponent (b) in the range of those reported for dicot trees (b = 0.22 in B. gasipaes; b = 0.31 and 0.23 in G. angustifolia). In B. gasipaes, vessels decrease in Dh from the stem's centre towards the periphery, an opposite pattern compared with dicot trees. Along the leaf rachis, a pattern of increasing Dh basally was also found (b = 0.13). The hydraulic design of the monocots studied revealed an axial pattern of xylem conduits similar to those evolved by dicots to compensate and minimize the negative effect of root-to-leaf length on hydrodynamic resistance to water flow.

  13. Modeling the axial offset anomaly in PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Blok, J.; Chauffriat, S.; Frattini, P. [EPRI, Palo Alto, CA (United States)

    2002-07-01

    Axially un-symmetrical flux depression is defined as axial offset anomaly (AOA) in PWRs. The effect has only been observed in PWR reactor cores operated at high power duty. The threat of AOA limits the aggressiveness of core design, and in extreme form, the effect can decrease shutdown margin near end of cycle (EOC) sufficiently to mandate power reduction. AOA is ultimately the result of boron hideout on fuel. Studies have confirmed that sufficient boron hideout to produce measurable AOA requires relatively large amounts of corrosion products to deposit on the fuel. Because corrosion product deposition is favored in the boiling upper regions of the (high duty) core, the amount of boron uptake in these regions is large in proportion, and core reactivity is affected disproportionately in the upper region of the core. This paper explores possible mechanisms for deposition of corrosion products on fuel and the consequent incorporation of boron compounds. The proposed mechanisms are viewed in the context of corrosion product samples from the Callaway Cycle 9, one of the PWR fuel cycles that exhibited the most severe AOA to date. (author)

  14. Extended Hamiltonian formalism of the pure space-like axial gauge Schwinger model

    International Nuclear Information System (INIS)

    Nakawaki, Yuji; Mccartor, Gary

    2001-01-01

    We demonstrate that pure space-like axial gauge quantizations of gauge fields can be constructed in ways that are free from infrared divergences. To do so, we must extend the Hamiltonian formalism to include residual gauge fields. We construct an operator solution and an extended Hamiltonian of the pure space-like axial gauge Schwinger model. We begin by constructing an axial gauge formation in auxiliary coordinates, x μ =(x + , x - ), where x + =x 0 sinθ + x 1 cosθ, x - =x 0 cosθ - x 1 sinθ, and we take A=A 0 cosθ + A 1 sin θ=0 as the gauge fixing condition. In the region 0 - as the evolution parameter and construct a traditional canonical formulation of the temporal gauge Schwinger model in which residual gauge fields dependent only on x + are static canonical variables. Then we extrapolate the temporal gauge operator solution into the axial region, π / 4 + is taken as the evolution parameter. In the axial region we find that we have to take the representation of the residual gauge fields realizing the Mandelstam-Leibbrandt prescription in order for the infrared divergences resulting from (∂) -1 to be canceled by corresponding ones resulting from the inverse of the hyperbolic Laplace operator. We overcome the difficulty of constructing the Hamiltonian for the residual gauge fields by employing McCartor and Robertson's method, which gives us a term integrated over x - =constant. Finally, by taking the limit θ→π / 2 - 0, we obtain an operator solution and the Hamiltonian of the axial gauge (Coulomb gauge) Schwinger model in ordinary coordinates. That solution includes auxiliary fields, and the representation space is of indefinite metric, providing further evidence that 'physical' gauges are no more physical than 'unphysical' gauges. (author)

  15. Subfoveal Choroidal Thickness and Axial Length in Preschool Children with Hyperopic Anisometropic Amblyopia.

    Science.gov (United States)

    Mori, Takafumi; Sugano, Yukinori; Maruko, Ichiro; Sekiryu, Tetsuju

    2015-09-01

    To investigate the relationship between subfoveal choroidal thickness and axial length in Japanese preschool children with hyperopic anisometropic amblyopia. Twenty-four children between the age of 3 and 6 years exhibiting hyperopic anisometropic amblyopia were examined. Differences in spherical equivalent between the two eyes were over 1.5 D in all children. Twenty-four eyes in 12 children without anisometropia and amblyopia were examined as age-matched normal controls. Subfoveal choroidal thickness was measured by using enhanced depth imaging optical coherence tomography. Axial length was measured with noncontact optical biometer. The spherical equivalent ranged from +3.50 to +7.25 D in amblyopic eyes and from +0.75 to +3.50 D in fellow eyes. The subfoveal choroidal thickness was significantly greater in the amblyopic eyes than that in the fellow eyes (407.3 ± 54.2 μm versus 357.7 ± 54.3 μm, Paired t-test, p amblyopia was greater than that in age matched normal children, although this difference did not reach statistical significance (326.0 ± 62.1 μm, p = 0.07). The subfoveal choroidal thickness in amblyopic children was negatively correlated with their axial length (r = -0.50, p < 0.01). The subfoveal choroidal thickness of amblyopic children abnormally increased and the thicker subfoveal choroid is mildly correlated with their shorter axial length. The anomalous subfoveal choroidal thicknesses in our amblyopic children may reflect a delay in emmetropization.

  16. Axial stress corrosion cracking forming method to metal tube

    International Nuclear Information System (INIS)

    Araki, Kumiko

    1998-01-01

    Generally, it is more difficult in a metal tube, to intentionally cause a stress corrosion cracking in axial direction than in circumferential direction. In the present invention, a bevel is formed on a metal tube and welding is conducted in circumferential direction along the bevel, and welding is conducted in axial direction partially to the portion welded in circumferential direction. Namely, a bevel is formed in circumferential direction to an abutting portion of thick-walled metal tubes with each other, welding is conducted in circumferential direction along the bevel, and welding is conducted in axial direction partially to a portion welded in circumferential direction. With such procedures, since tensile stress in the circumferential direction is increased partially at a portion welded in axial direction, stress corrosion cracking is caused in axial direction at the portion. Then, stress corrosion cracking in axial direction can thus be formed on the thick-walled metal tube. (N.H.)

  17. Revisiting the vector and axial-vector vacuum susceptibilities

    International Nuclear Information System (INIS)

    Chang Lei; Liu Yuxin; Sun Weimin; Zong Hongshi

    2008-01-01

    We re-investigate the vector and axial-vector vacuum susceptibilities by taking advantage of the vector and axial-vector Ward-Takahashi identities. We show analytically that, in the chiral limit, the vector vacuum susceptibility is zero and the axial-vector vacuum susceptibility equals three fourths of the square of the pion decay constant. Besides, our analysis reproduces the Weinberg sum rule

  18. Aerodynamic Modelling and Optimization of Axial Fans

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft

    A numerically efficient mathematical model for the aerodynamics oflow speed axial fans of the arbitrary vortex flow type has been developed.The model is based on a blade-element principle, whereby therotor is divided into a number of annular streamtubes.For each of these streamtubes relations...... and integrated propertiesshow that the computed results agree well with the measurements.Integrating a rotor-only version of the aerodynamic modelwith an algorithm for numerical designoptimization, enables the finding of an optimum fan rotor.The angular velocity of the rotor, the hub radius and the spanwise...... of fan efficiency in a design interval of flow rates,thus designinga fan which operates well over a range of different flow conditions.The optimization scheme was used to investigate the dependence ofmaximum efficiency on1: the number of blades,2: the width of the design interval and3: the hub radius...

  19. Geometric inequalities for axially symmetric black holes

    International Nuclear Information System (INIS)

    Dain, Sergio

    2012-01-01

    A geometric inequality in general relativity relates quantities that have both a physical interpretation and a geometrical definition. It is well known that the parameters that characterize the Kerr-Newman black hole satisfy several important geometric inequalities. Remarkably enough, some of these inequalities also hold for dynamical black holes. This kind of inequalities play an important role in the characterization of the gravitational collapse; they are closely related with the cosmic censorship conjecture. Axially symmetric black holes are the natural candidates to study these inequalities because the quasi-local angular momentum is well defined for them. We review recent results in this subject and we also describe the main ideas behind the proofs. Finally, a list of relevant open problems is presented. (topical review)

  20. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The objects of this invention are first to reduce the time required to obtain statistically significant data in trans-axial tomographic radioisotope scanning using a scintillation camera. Secondly, to provide a scintillation camera system to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a known radiation source without sacrificing spatial resolution. Thirdly to reduce the scanning time without loss of image clarity. The system described comprises a scintillation camera detector, means for moving this in orbit about a cranial-caudal axis relative to a patient and a collimator having septa defining apertures such that gamma rays perpendicular to the axis are admitted with high spatial resolution, parallel to the axis with low resolution. The septa may be made of strips of lead. Detailed descriptions are given. (U.K.)

  1. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The principal problem in trans-axial tomographic radioisotope scanning is the length of time required to obtain meaningful data. Patient movement and radioisotope migration during the scanning period can cause distortion of the image. The object of this invention is to reduce the scanning time without degrading the images obtained. A system is described in which a scintillation camera detector is moved to an orbit about the cranial-caudal axis relative to the patient. A collimator is used in which lead septa are arranged so as to admit gamma rays travelling perpendicular to this axis with high spatial resolution and those travelling in the direction of the axis with low spatial resolution, thus increasing the rate of acceptance of radioactive events to contribute to the positional information obtainable without sacrificing spatial resolution. (author)

  2. Axial flux data for fuel measurement

    Energy Technology Data Exchange (ETDEWEB)

    Popovich, R.P.

    1964-02-11

    A survey of the PITA-18 nonpoisonous spline program was conducted in conjunction with a study to determine the best method of eliminating the variability of axial flux on the fuel performance parameter, q. The results of this survey and the conclusions reached in the rupture coefficient study were found to be inter-dependent such that both are presented in this report. The data from the PITA-18 nonpoisonous spline program, as received, is the output of the NOLA-2 computer program. One quantity of interest is the rupture potential relative to a cosine, commonly referred to as the relative rupture potential. As programmed, the relative rupture potential, which was derived by applying the rupture model to individual fuel elements, might be expected to vary linearly with the rupture rate. The use of the relative rupture potential was studied over the period of July 1962 through December 1963. The results of this study are presented.

  3. Composite Axial Flow Propulsor for Small Aircraft

    Directory of Open Access Journals (Sweden)

    R. Poul

    2005-01-01

    Full Text Available This work focuses on the design of an axial flow ducted fan driven by a reciprocating engine. The solution minimizes the turbulization of the flow around the aircraft. The fan has a rotor - stator configuration. Due to the need for low weight of the fan, a carbon/epoxy composite material was chosen for the blades and the driving shaft.The fan is designed for optimal isentropic efficiency and free vortex flow. A stress analysis of the rotor blade was performed using the Finite Element  Method. The skin of the blade is calculated as a laminate and the foam core as a solid. A static and dynamic analysis were made. The RTM technology is compared with other technologies and is described in detail. 

  4. Toward spectral-domain optical coherence tomography on a silicon chip

    NARCIS (Netherlands)

    Akça, B.I.; Povazay, B.; Alex, A.; Worhoff, Kerstin; de Ridder, R.M.; Drexler, W.; Pollnau, Markus

    In-vivo imaging was demonstrated with a depth range of 1.4 mm and axial resolution of 7.5 µm by using a miniaturized spectral-domain optical coherence tomography system comprising an integrated spectrometer and a beam splitter.

  5. Estimation of ocular volume from axial length.

    Science.gov (United States)

    Nagra, Manbir; Gilmartin, Bernard; Logan, Nicola S

    2014-12-01

    To determine which biometric parameters provide optimum predictive power for ocular volume. Sixty-seven adult subjects were scanned with a Siemens 3-T MRI scanner. Mean spherical error (MSE) (D) was measured with a Shin-Nippon autorefractor and a Zeiss IOLMaster used to measure (mm) axial length (AL), anterior chamber depth (ACD) and corneal radius (CR). Total ocular volume (TOV) was calculated from T2-weighted MRIs (voxel size 1.0 mm(3)) using an automatic voxel counting and shading algorithm. Each MR slice was subsequently edited manually in the axial, sagittal and coronal plane, the latter enabling location of the posterior pole of the crystalline lens and partitioning of TOV into anterior (AV) and posterior volume (PV) regions. Mean values (±SD) for MSE (D), AL (mm), ACD (mm) and CR (mm) were -2.62±3.83, 24.51±1.47, 3.55±0.34 and 7.75±0.28, respectively. Mean values (±SD) for TOV, AV and PV (mm(3)) were 8168.21±1141.86, 1099.40±139.24 and 7068.82±1134.05, respectively. TOV showed significant correlation with MSE, AL, PV (all p<0.001), CR (p=0.043) and ACD (p=0.024). Bar CR, the correlations were shown to be wholly attributable to variation in PV. Multiple linear regression indicated that the combination of AL and CR provided optimum R(2) values of 79.4% for TOV. Clinically useful estimations of ocular volume can be obtained from measurement of AL and CR. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  7. Effects of axial, transverse, and oblique sample motion in FD OCT in systems with global or rolling shutter line detector.

    Science.gov (United States)

    Walther, Julia; Krüger, Alexander; Cuevas, Maximiliano; Koch, Edmund

    2008-11-01

    This study deals with effects on the interference signal caused by axial, transverse, and oblique motion in spectrometer-based Fourier-domain optical coherence tomography (FD OCT). Two different systems are compared-one with a global shutter line detector and the other with a rolling shutter. We present theoretical and experimental investigations of motion artifacts. Regarding axial motion, fringe washout is observed in both systems, and an additional Doppler frequency shift is seen in the system using a rolling shutter. In addition, both systems show the same SNR decrease as a result of a transversely and obliquely moving sample. The possibility of flow measurement by using the decrease in signal power was demonstrated by imaging 1% Intralipid emulsion flowing through a glass capillary. This research provides an understanding of the SNR degradation caused by sample motion and demonstrates the importance of fast data acquisition in medical imaging.

  8. The clinical significance of computerized axial tomography (CAT) in consideration of conventional diagnostic methods

    International Nuclear Information System (INIS)

    Huenig, R.

    1976-01-01

    Regarding CAT of the intracranial region, the article informs on a) techniques of examination including the production of normal structures, b) the recognizable pathological changes, c) possibilities of enhancement, d) possibilities of course observation, e) limitations of the methods, as well as on f) risk/benefit aspects g) benefit/cost calculations as compared to conventional methods, and on h) the influence of CAT on the frequency of conventional methods of examination. Regarding CAT of the extracranial region, the information available up to the meeting is reported on. (orig./LH) [de

  9. The clinical value of computerized axial tomography in patients without focal neurological features

    International Nuclear Information System (INIS)

    Lundorf, E.; Nielson, M.B.

    1985-01-01

    74 randomly selected patients with non-focal cerebral symptoms and a normal neurologic examination were referred from neurologic departments to CT scan of the brain. 29 patients had generalised epilepsy of long duration. In 26 patients (90%) with epilepsy the Ct scan was normal. 2 patients (7%) had cerebral atrophy, 1 (3%) showed porencephaly (.) 41 (91%) of the patients without epileptic features had a normal CT scan. 4 (9%) presented cerebral atrophy. In this survey, Ct scanning did not contribute to a focal diagnosis in patients with diffuse cerebral features. (orig.) [de

  10. Analysis of peritumoral edema and contrast enhancement by computerized axial tomography

    International Nuclear Information System (INIS)

    Oi, Shizuo; Szper, I.; Wetzel, N.; Kim, Kwang-S.

    1980-01-01

    For the purpose of treating brain tumors satisfactorily with steroids, CT findings of brain tumors were analyzed, and pathogenesis of peritumoral edema and supposed effects of steroids were investigated. The degree of peritumoral edema and contrast enhancement and their relationship were analyzed in total 201 patients with brain tumors (gliomas, meningiomas, and metastatic brain tumors). As a result, significant peritumoral edema was recognized in 59% of patients with metastatic brain tumors, 46% of patients with glioma, and 34% of patients with meningioma. As a rule, there was a relationship between peritumoral edema and malignancy or localization of braiin tumors. Severe peritumoral edema was observed in malignant supratentorial tumors (over 60%), but peritumoral edema which was found in infratentorial tumors benign gliomas was mild. The degree of contrast enhancement differed according to tumors, and there was not always a relationship between the degree of contrast enhancement and malignancy or localization of brain tumors. CT findings of brain tumors after the administration of steroids showed decrease in the degree of contrast enhancement. Judging from the effect of steroids to inhibit increased vascular permeability associated with brain edema, like CT findings of peritumoral edema, the degree of contrast enhancement which probably expressed vascularity or vascular permeability seemed to be important in deciding the indications for steroid administration. (Tsunoda, M.)

  11. Equation of motion for the axial gravitational superfield

    International Nuclear Information System (INIS)

    Ogievetsky, V.; Sokatchev, E.

    1980-01-01

    Transformation properties of the axial supergravitational field variants are investigated. The equation of motion for the axial gravitational superfield is derived by direct variation of the N = 1 supergravity action. The left-hand side of this equation is a component of the torsion tensor, and the right-hand side is the supercurrent. The question about the cosmological term in supergravity is discussed

  12. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  13. Bi-axial quartz as a stress indicator

    Science.gov (United States)

    Starkey, John

    2000-03-01

    Experiments confirm that stress causes quartz to become biaxial with the optical axial plane parallel to the direction of maximum applied stress. Five tectonites were studied for which published data indicate strong patterns of preferred orientation of quartz. Conoscopic investigation, using an optical universal stage, reveals that the quartz in these rocks is biaxial with the 2V as large as 22°. The optic axial planes display strong patterns of preferred orientation. In the natural tectonites the maximum stress directions deduced from the orientations of the optical axial planes cannot be correlated with the supposed tectonic framework responsible for the quartz orientation fabric. The ease with which quartz can be made biaxial experimentally suggests that the orientation of the optic axial planes may be sensitive to tectonic events which affected the rocks subsequent to the development of the quartz orientation fabrics. The analysis of the orientation of optic axial planes in biaxial quartz may provide a tool for the investigation of neotectonics.

  14. Nucleon axial coupling from Lattice QCD

    Science.gov (United States)

    Cheng Chang, Chia; Nicholson, Amy; Rinaldi, Enrico; Berkowitz, Evan; Garron, Nicolas; Brantley, David; Monge-Camacho, Henry; Monahan, Chris; Bouchard, Chris; Clark, M. A.; Joó, Bálint; Kurth, Thorsten; Orginos, Kostas; Vranas, Pavlos; Walker-Loud, André

    2018-03-01

    We present state-of-the-art results from a lattice QCD calculation of the nucleon axial coupling, gA, using Möbius Domain-Wall fermions solved on the dynamical Nf = 2 + 1 + 1 HISQ ensembles after they are smeared using the gradient-flow algorithm. Relevant three-point correlation functions are calculated using a method inspired by the Feynman-Hellmann theorem, and demonstrate significant improvement in signal for fixed stochastic samples. The calculation is performed at five pion masses of mπ {400, 350, 310, 220, 130} MeV, three lattice spacings of a {0.15, 0.12, 0.09} fm, and we do a dedicated volume study with mπL {3.22, 4.29, 5.36}. Control over all relevant sources of systematic uncertainty are demonstrated and quantified. We achieve a preliminary value of gA = 1.285(17), with a relative uncertainty of 1.33%.

  15. Axial sheath dynamics in a plasma focus

    International Nuclear Information System (INIS)

    Soliman, H.M.; El-Khalafawy, T.A.; Masoud, M.M.

    1990-01-01

    This paper presents the result of investigation with a 10 kJ Mather type plasma focus. It is operated in hydrogen gas at ambient pressure of 0.15--1 torr and charging voltage of 8--11 kV. Radial distribution of the current sheath density with axial distance has been estimated. Plasma rotation in the expansion chamber in the absence of external magnetic field has been detected. A plasma flare from the plasma focus region propagating in the radial direction has been observed. Streak photography shows two plasma streams flowing simultaneously out of the muzzle. The mean energy of the electron beam ejected from the pinch region of the focused plasma, was measured by retarding field analyzer to be 0.32 keV. The electron temperature of the plasma focus at peak compression was determined by measuring the X-ray intensity as a function of absorber thickness at a distance of 62 cm from the focus. The electron temperature has been found to 3 keV

  16. Nitinol stent design - understanding axial buckling.

    Science.gov (United States)

    McGrath, D J; O Brien, B; Bruzzi, M; McHugh, P E

    2014-12-01

    Nitinol׳s superelastic properties permit self-expanding stents to be crimped without plastic deformation, but its nonlinear properties can contribute towards stent buckling. This study investigates the axial buckling of a prototype tracheobronchial nitinol stent design during crimping, with the objective of eliminating buckling from the design. To capture the stent buckling mechanism a computational model of a radial force test is simulated, where small geometric defects are introduced to remove symmetry and allow buckling to occur. With the buckling mechanism ascertained, a sensitivity study is carried out to examine the effect that the transitional plateau region of the nitinol loading curve has on stent stability. Results of this analysis are then used to redesign the stent and remove buckling. It is found that the transitional plateau region can have a significant effect on the stability of a stent during crimping, and by reducing the amount of transitional material within the stent hinges during loading the stability of a nitinol stent can be increased. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Rare location of spondylitis tuberculosis;atlanto-axial, sacral and cervico-thoracic junction

    Science.gov (United States)

    Victorio; Nasution, M. D.; Ibrahim, S.; Dharmajaya, R.

    2018-03-01

    Three cases of rare location spondylitis tuberculosis are reported, each in atlantoaxial, cervico-thoracic junction,and sacral. The complaints were aweakness of motoric strength and local back pain. Patients’thoracal x-ray was normal, there was no complaint of acough, PCR forTB was early diagnostic and positive in all three cases, HIV negative, intraoperative tissue samplings were sent for histopathology examination and the results showed thespecific inflammatory process. Lesions were evaluated with computer tomography and/or MRI imaging.Preoperative TB regimens therapy were given for 2 weeks and continued for nine months. The surgical procedurewas done in all cases with excellent improvement of symptoms and motoric strength. In our institution,25 cases of total TB spondylitis were performed in 2 years, only 1 case eachwas found in atlanto-axial, cervico-thoracic and sacral.

  18. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  19. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  1. New classes of bi-axially symmetric solutions to four-dimensional Vasiliev higher spin gravity

    Energy Technology Data Exchange (ETDEWEB)

    Sundell, Per; Yin, Yihao [Departamento de Ciencias Físicas, Universidad Andres Bello,Republica 220, Santiago de Chile (Chile)

    2017-01-11

    We present new infinite-dimensional spaces of bi-axially symmetric asymptotically anti-de Sitter solutions to four-dimensional Vasiliev higher spin gravity, obtained by modifications of the Ansatz used in https://arxiv.org/abs/1107.1217, which gave rise to a Type-D solution space. The current Ansatz is based on internal semigroup algebras (without identity) generated by exponentials formed out of the bi-axial symmetry generators. After having switched on the vacuum gauge function, the resulting generalized Weyl tensor is given by a sum of generalized Petrov type-D tensors that are Kerr-like or 2-brane-like in the asymptotic AdS{sub 4} region, and the twistor space connection is smooth in twistor space over finite regions of spacetime. We provide evidence for that the linearized twistor space connection can be brought to Vasiliev gauge.

  2. Quantitative analysis of cone photoreceptor distribution and its relationship with axial length, age, and early age-related macular degeneration.

    Directory of Open Access Journals (Sweden)

    Ryo Obata

    Full Text Available PURPOSE: It has not been clarified whether early age-related macular degeneration (AMD is associated with cone photoreceptor distribution. We used adaptive optics fundus camera to examine cone photoreceptors in the macular area of aged patients and quantitatively analyzed its relationship between the presence of early AMD and cone distribution. METHODS: Sixty cases aged 50 or older were studied. The eyes were examined with funduscopy and spectral-domain optical coherence tomography to exclude the eyes with any abnormalities at two sites of measurement, 2° superior and 5° temporal to the fovea. High-resolution retinal images with cone photoreceptor mosaic were obtained with adaptive optics fundus camera (rtx1, Imagine Eyes, France. After adjusting for axial length, cone packing density was calculated and the relationship with age, axial length, or severity of early AMD based on the age-related eye disease study (AREDS classification was analyzed. RESULTS: Patient's age ranged from 50 to 77, and axial length from 21.7 to 27.5 mm. Mean density in metric units and that in angular units were 24,900 cells/mm2, 2,170 cells/deg2 at 2° superior, and 18,500 cells/mm2, 1,570 cels/deg2 at 5° temporal, respectively. Axial length was significantly correlated with the density calculated in metric units, but not with that in angular units. Age was significantly correlated with the density both in metric and angular units at 2° superior. There was no significant difference in the density in metric and angular units between the eyes with AREDS category one and those with categories two or three. CONCLUSION: Axial length and age were significantly correlated with parafoveal cone photoreceptor distribution. The results do not support that early AMD might influence cone photoreceptor density in the area without drusen or pigment abnormalities.

  3. Metastatic disease of the brain: extra-axial metastases (skull, dura, leptomeningeal) and tumour spread.

    Science.gov (United States)

    Maroldi, Roberto; Ambrosi, Claudia; Farina, Davide

    2005-03-01

    Extra-axial intracranial metastases may arise through several situations. Hematogenous spread to the meninges is the most frequent cause. Direct extension from contiguous extra-cranial neoplasms, secondary invasion of the meninges by calvarium and skull base metastases, and migration along perineural or perivascular structures are less common. Leptomeningeal invasion gives rise to tumour cell dissemination by the cerebrospinal fluid (CSF), eventually leading to neoplastic coating of brain surfaces. Contrast-enhanced magnetic resonance (MR) imaging is complementary to CSF examinations and can be invaluable, detecting up to 50% of false-negative lumbar punctures. MR findings range from diffuse linear leptomeningeal enhancement to multiple enhancing extra-axial nodules, obstructive communicating and non-communicating hydrocephalus. Both calvarial and epidural metastases infrequently transgress the dura, which acts as a barrier against tumour spread. Radionuclide bone studies are still a valuable screening test to detect bone metastases. With computed tomography (CT) and MR, bone metastases extending intracranially and primary dural metastases show the characteristic biconvex shape, usually associated with brain displacement away from the inner table. Although CT is better in detecting skull base erosion, MR is more sensitive and provides more detailed information about dural involvement. Perineural and perivascular spread from head and neck neoplasms require thin-section contrast-enhanced MR.

  4. Metastatic disease of the brain: extra-axial metastases (skull, dura, leptomeningeal) and tumour spread

    Energy Technology Data Exchange (ETDEWEB)

    Maroldi, Roberto; Ambrosi, Claudia; Farina, Davide [University of Brescia, Department of Radiology, Brescia, BS (Italy)

    2005-03-01

    Extra-axial intracranial metastases may arise through several situations. Hematogenous spread to the meninges is the most frequent cause. Direct extension from contiguous extra-cranial neoplasms, secondary invasion of the meninges by calvarium and skull base metastases, and migration along perineural or perivascular structures are less common. Leptomeningeal invasion gives rise to tumour cell dissemination by the cerebrospinal fluid (CSF), eventually leading to neoplastic coating of brain surfaces. Contrast-enhanced magnetic resonance (MR) imaging is complementary to CSF examinations and can be invaluable, detecting up to 50% of false-negative lumbar punctures. MR findings range from diffuse linear leptomeningeal enhancement to multiple enhancing extra-axial nodules, obstructive communicating and non-communicating hydrocephalus. Both calvarial and epidural metastases infrequently transgress the dura, which acts as a barrier against tumour spread. Radionuclide bone studies are still a valuable screening test to detect bone metastases. With computed tomography (CT) and MR, bone metastases extending intracranially and primary dural metastases show the characteristic biconvex shape, usually associated with brain displacement away from the inner table. Although CT is better in detecting skull base erosion, MR is more sensitive and provides more detailed information about dural involvement. Perineural and perivascular spread from head and neck neoplasms require thin-section contrast-enhanced MR. (orig.)

  5. Spectral-domain optical coherence tomography of macula in myopia.

    Science.gov (United States)

    Choovuthayakorn, Janejit; Laowong, Taksaorn; Watanachai, Nawat; Patikulsila, Direk; Chaikitmongkol, Voraporn

    2016-06-01

    The aim of this study is to determine the associations between regional macular thickness and gender, age, axial length, and degree of myopia in young and middle-aged healthy myopic eyes. One hundred and seventy-one subjects with -0.5 diopters of myopia or worse underwent prospective macular thickness measurement by Spectralis spectral-domain optical coherence tomography. Subjects' mean age was 32.40 ± 8.25 years (range 18 to 49 years), with 45 % being male. The mean degree of myopia was -4.57 ± 3.52 diopters, with a mean axial length of 25.09 ± 1.67 mm. Multivariate regression analysis demonstrated significantly thicker central (mean 9.13 µm thicker) and inner subfields (mean 8.55 µm thicker) in males (P values were <0.001 and 0.002, respectively). In addition, in both genders, for each millimeter of increased axial length, the central subfield thickness increased by 2.11 µm, the inner subfield decreased by 2.25 µm, and the outer subfield decreased by 3.62 µm (P values were 0.010, <0.001, and <0.001, respectively). Factors including gender and axial length affect baseline regional macular thickness in young and middle-age myopic subjects. The central subfield and inner subfield were affected by both gender and axial length, while the outer subfield was affected only by axial length. The macular thickness of myopic subjects with macular disease should be interpreted in light of these factors.

  6. Conservative axial burnup distributions for actinide-only burnup credit

    International Nuclear Information System (INIS)

    Kang, C.; Lancaster, D.

    1997-11-01

    Unlike the fresh fuel approach, which assumes the initial isotopic compositions for criticality analyses, any burnup credit methodology must address the proper treatment of axial burnup distributions. A straightforward way of treating a given axial burnup distribution is to segment the fuel assembly into multiple meshes and to model each burnup mesh with the corresponding isotopic compositions. Although this approach represents a significant increase in modeling efforts compared to the uniform average burnup approach, it can adequately determine the reactivity effect of the axial burnup distribution. A major consideration is what axial burnup distributions are appropriate for use in light of many possible distributions depending on core operating conditions and histories. This paper summarizes criticality analyses performed to determine conservative axial burnup distributions. The conservative axial burnup distributions presented in this paper are included in the Topical Report on Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel Packages, Revision 1 submitted in May 1997 by the US Department of Energy (DOE) to the US Nuclear Regulatory Commission (NRC). When approved by NRC, the conservative axial burnup distributions may be used to model PWR spent nuclear fuel for the purpose of gaining actinide only burnup credit

  7. Axial elongation following prolonged near work in myopes and emmetropes.

    Science.gov (United States)

    Woodman, Emily C; Read, Scott A; Collins, Michael J; Hegarty, Katherine J; Priddle, Scott B; Smith, Josephine M; Perro, Judd V

    2011-05-01

    To investigate the influence of a period of sustained near work upon axial length in groups of emmetropes (EMM) and myopes. Forty young adult subjects (20 myopes and 20 emmetropes) were recruited for the study. Myopes were further classified as early onset (EOM), late onset (LOM), stable (SM) or progressing (PM) subgroups. Axial length was measured with the IOLMaster instrument before, immediately after and then again 10 min after a continuous 30 min near task of 5 D accommodation demand. Measures of distance objective refraction were also collected. Significant changes in axial length were observed immediately following the near task. EOM axial length elongated on average by 0.027±0.021 mm, LOM by 0.014±0.020 mm, EMM by 0.010±0.015 mm, PM by 0.031±0.022 mm and SM by 0.014±0.018 mm. At the conclusion of the 10 min regression period, axial length measures were not significantly different from baseline values. Axial elongation was observed following a prolonged near task. Both EOM and PM groups showed increases in axial length that were significantly greater than emmetropes.

  8. Dispositivos de asistencia ventricular de tipo axial

    Directory of Open Access Journals (Sweden)

    Albert Miralles Cassina

    2009-04-01

    Full Text Available El uso de dispositivos de asistencia ventricular se ha ido extendiendo en las últimas décadas. La mejora de los resultados ha ido acompañada del diseño de nuevos aparatos más pequeños y eficientes como son las bombas de flujo axial. las características técnicas básicas de estos dispositivos se hallan en la generación de un flujo continuo unidireccional conseguido mediante sistemas de turbina que obtienen su alimentación de una fuente eléctrica. Las ventajas principales de estos dispositivos son: su facilidad de implantación por su tamaño reducido, su prolongada durabilidad gracias a su sencillo diseño y su eficiencia energética al utilizar energía eléctrica. Su utilidad se ha podido demostrar en diferentes indicaciones de asistencia circulatoria mecánica, como en el caso de puente al trasplante o dispositivo de recuperación miocárdica, si bien donde radica más interés es en su uso como sistemas de asistencia circulatoria mecánica definitiva. Existe una variedad de modelos de diversos diseños. Son dispositivos que permiten soporte normalmente univentricular izquierdo, que se implantan en el tórax con cánula de entrada a nivel ventricular y cánula de salida a nivel aórtico. En este artículo se efectúa una descripción de los principales sistemas disponibles en la actualidad, comentando las características técnicas, ventajas e inconvenientes y un resumen de la experiencia existente.

  9. Computed tomography findings in convergent strabismus fixus

    International Nuclear Information System (INIS)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio

    1995-01-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author)

  10. Computed tomography of atresia auris congenita

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke; Koide, Fujio

    1983-01-01

    Computed tomography was performed in 9 patients with atresia auris congenita. In this study, scans were done in axial or coronal projection with the CT/T body scanner. The external auditory canals were involved in varying degrees from mild narrowing to complete atresia. In partial atresia, CT scanning demonstrated the patency of the canal, and also showed the cardrum as a clearly defined soft tissue. Simulatenously, the associated middle ear anomalies were well demonstrated. One of the most common deformities of the ossicular chains was fusion of the malleus and incus. In some cases, these ossicles were dislocated, and occasionally were fixed to the atresia plate or attic wall. Other variations of the temporal bone could be assumed. We concluded that CT is the technique of choice to evaluate patients with atresia auris congenita. (author)

  11. Radial loads and axial thrusts on centrifugal pumps

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The proceedings of a seminar organised by the Power Industries Division of the IMechE are presented in this text. Complete contents: Review of parameters influencing hydraulic forces on centrifugal impellers; The effect of fluid forces at various operation conditions on the vibrations of vertical turbine pumps; A review of the pump rotor axial equilibrium problem - some case studies; Dynamic hydraulic loading on a centrifugal pump impeller; Experimental research on axial thrust loads of double suction centrifugal pumps; A comparison of pressure distribution and radial loads on centrifugal pumps; A theoretical and experimental investigation of axial thrusts within a multi-stage centrifugal pump

  12. Measurement for cobalt target activity and its axial distribution

    International Nuclear Information System (INIS)

    Li Xingyuan; Chen Zigen.

    1985-01-01

    Cobalt target activity and its axial distribution are measured in process of producing radioactive isotopes 60 Co by irradiation in HFETR. Cobalt target activity is obtained with measured data at 3.60 m and 4.60 m, relative axial distribution of cobalt target activity is obtained with one at 30 cm, and axial distribution of cobalt target activity(or specific activity) is obtained with both of data. The difference between this specific activity and measured result for 60 Co teletherapy sources in the end is less than +- 5%

  13. Axial weak currents in the Wess-Zumino term

    International Nuclear Information System (INIS)

    Fujikawa, Kazuo.

    1985-03-01

    The conventional axial gauging of the Wess-Zumino term leads to the results which do not necessarily agree with the expectations on the basis of quark level Ward-Takahashi identities. This discrepancy arises from the fact that the quark level anomalous identities reflect the short distance structure of QCD, whereas the gauging of the Wess-Zumino term reflects the axial symmetry in the spontaneously broken chiral phase. The low energy theorem for axial weak fields is not sharply defined, in contrast to the case of vector fields where no such complications arise. (author)

  14. The Design Method of Axial Flow Runners Focusing on Axial Flow Velocity Uniformization and Its Application to an Ultra-Small Axial Flow Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2016-01-01

    Full Text Available We proposed a portable and ultra-small axial flow hydraulic turbine that can generate electric power comparatively easily using the low head of open channels such as existing pipe conduits or small rivers. In addition, we proposed a simple design method for axial flow runners in combination with the conventional one-dimensional design method and the design method of axial flow velocity uniformization, with the support of three-dimensional flow analysis. Applying our design method to the runner of an ultra-small axial flow hydraulic turbine, the performance and internal flow of the designed runner were investigated using CFD analysis and experiment (performance test and PIV measurement. As a result, the runners designed with our design method were significantly improved in turbine efficiency compared to the original runner. Specifically, in the experiment, a new design of the runner achieved a turbine efficiency of 0.768. This reason was that the axial component of absolute velocity of the new design of the runner was relatively uniform at the runner outlet in comparison with that of the original runner, and as a result, the negative rotational flow was improved. Thus, the validity of our design method has been verified.

  15. The Nonradiographic Axial Spondyloarthritis, the Radiographic Axial Spondyloarthritis, and Ankylosing Spondylitis: The Tangled Skein of Rheumatology

    Science.gov (United States)

    Rawat, Roopa; Agrawal, Neha; Patil, Nilesh S.

    2017-01-01

    Since 1984 the diagnosis of ankylosing spondylitis (AS) has been based upon the modified New York (mNY) criteria with mandatory presence of radiographic sacroiliitis, without which the diagnosis is not tenable. However, it may take years or decades for radiographic sacroiliitis to develop delaying the diagnosis for long periods. It did not matter in the past because no effective treatment was available. However, with the availability of a highly effective treatment, namely, tumour necrosis factor-α inhibitors (TNFi), the issue of early diagnosis of AS acquired an urgency. The Assessment of SpondyloArthritis International Society (ASAS) classification criteria published in 2009 was a significant step towards this goal. These criteria described an early stage of the disease where sacroiliitis was demonstrable only on MRI but not on standard radiograph. Therefore, this stage of the disease was labelled “nonradiographic axial SpA” (nr-axSpA). But questions have been raised if, in search of early diagnosis, specificity was compromised. The Federal Drug Administration (FDA, USA) withheld approval for the use of TNFi in patients with nr-axSpA because of issues related to the specificity of these criteria. This review attempts to clarify some of these aspects of the nr-axSpA-AS relationship and also tries to answer the question whether ASAS classifiable radiographic axial spondyloarthritis (r-axSpA) term can be interchangeably used with the term AS. PMID:28555158

  16. Cladding axial elongation models for FRAP-T6

    International Nuclear Information System (INIS)

    Shah, V.N.; Carlson, E.R.; Berna, G.A.

    1983-01-01

    This paper presents a description of the cladding axial elongation models developed at the Idaho National Engineering Laboratory (INEL) for use by the FRAP-T6 computer code in analyzing the response of fuel rods during reactor transients in light water reactors (LWR). The FRAP-T6 code contains models (FRACAS-II subcode) that analyze the structural response of a fuel rod including pellet-cladding-mechanical-interaction (PCMI). Recently, four models were incorporated into FRACAS-II to calculate cladding axial deformation: (a) axial PCMI, (b) trapped fuel stack, (c) fuel relocation, and (d) effective fuel thermal expansion. Comparisons of cladding axial elongation measurements from two experiments with the corresponding FRAP-T6 calculations are presented

  17. The relation between anomalous magnetic moment and axial anomaly

    International Nuclear Information System (INIS)

    Teryaev, O.V.

    1990-12-01

    The conservation of total angular momentum of spinor particle leads to a simple relation between the famous Schwinger and Adler coefficients determining axial anomaly and anomalous magnetic moment, respectively. (author). 8 refs, 1 fig

  18. Defining active sacroiliitis on MRI for classification of axial spondyloarthritis

    DEFF Research Database (Denmark)

    Lambert, Robert G W; Bakker, Pauline A C; van der Heijde, Désirée

    2016-01-01

    OBJECTIVES: To review and update the existing definition of a positive MRI for classification of axial spondyloarthritis (SpA). METHODS: The Assessment in SpondyloArthritis International Society (ASAS) MRI working group conducted a consensus exercise to review the definition of a positive MRI...... for inclusion in the ASAS classification criteria of axial SpA. Existing definitions and new data relevant to the MRI diagnosis and classification of sacroiliitis and spondylitis in axial SpA, published since the ASAS definition first appeared in print in 2009, were reviewed and discussed. The precise wording....... CONCLUSION: The definition of a positive MRI for classification of axial SpA should continue to primarily depend on the imaging features of 'active sacroiliitis' until more data are available regarding MRI features of structural damage in the sacroiliac joint and MRI features in the spine and their utility...

  19. The geometrical theory of diffraction for axially symmetric reflectors

    DEFF Research Database (Denmark)

    Rusch, W.; Sørensen, O.

    1975-01-01

    The geometrical theory of diffraction (GTD) (cf. [1], for example) may be applied advantageously to many axially symmetric reflector antenna geometries. The material in this communication presents analytical, computational, and experimental results for commonly encountered reflector geometries...

  20. The impact of degenerative spinal changes on the correlation of peripheral and axial bone density

    International Nuclear Information System (INIS)

    Schneider, P.; Boerner, W.

    1994-01-01

    Results of bone density measurements by quantitative computed tomography of the peripheral skeleton (pQCT) were compared with those of measurements at the axial skeleton with a view to study the effects of degenerative spinal changes on the validity of bone densitometry of the lumbar spine. 556 consecutive patients were examined by dual-energy X-ray absorptiometry (DXA) of the spine and by peripheral quantitative computed tomography (pQCT) of the distal radius. There were significant differences between the bone mineral values at the distal radius and those at the spine, depending on the degree of spinal degeneration. As expected, spinal degenerations showed a highly significant age dependence. With increasing degeneration the correlations between the radius total bone mineral concentration and the bone density of the lumbar spine decreased from r=0.45 to 0.23 in women and from r=0.64 to 0.28 in men. We conclude that the value of spinal DXA is reduced in patients with degenerative spinal disease, compared to the pQCT at the peripheral skeleton. (orig.) [de

  1. Pole prescription in axial gauge at finite temperature

    Science.gov (United States)

    Kreuzer, Maximilian; Nachbagauer, Herbert

    1991-11-01

    We establish Yang-Mills theory at finite temperature in axial gauge. We encounter the breakdown of the Hata-Kugo expression for the partition function in the special choice of temporal axial gauge. For n ≠ 0 the finite temperature propagator is calculated in both the imaginary time formalism and the real time formalism. In the latter we recover the Leibbrandt-Mandelstam prescription in the lijit T→0. As a check we calculate the mean energy to lowest order.

  2. Pole prescription in axial gauge at finite temperature

    Energy Technology Data Exchange (ETDEWEB)

    Kreuzer, M.; Nachbagauer, H. (Technische Univ., Vienna (Austria). Inst. fuer Theoretische Physik)

    1991-11-14

    We establish Yang-Mills theory at finite temperature in axial gauge. We encounter the breakdown of the Hata-Kugo expression for the partition function in the special choice of temporal axial gauge. For n {ne} 0 the finite temperature propagator is calculated in both the imaginary time formalism and the real time formalism. In the latter we recover the Leibbrandt-Mandelstam prescription in the limit T {yields} 0. As a check we calculate the mean energy to lowest order. (orig.).

  3. Flutter of a fan blade in supersonic axial flow

    Science.gov (United States)

    Kielb, Robert E.; Ramsey, John K.

    1988-01-01

    An application of a simple aeroelastic model to an advanced supersonic axial flow fan is presented. Lane's cascade theory is used to determine the unsteady aerodynamic loads. Parametric studies are performed to determine the effects of mode coupling, Mach number, damping, pitching axis location, solidity, stagger angle, and mistuning. The results show that supersonic axial flow fan and compressor blades are susceptible to a strong torsional mode flutter having critical reduced velocities which can be less than one.

  4. Osteolytic extra-axial sacral myxopapillary ependymoma

    International Nuclear Information System (INIS)

    Biagini, R.; Demitri, S.; Orsini, U.; Bibiloni, J.; Briccoli, A.; Bertoni, F.

    1999-01-01

    The authors report an unusual case of sacral osteolytic myxopapillary ependymoma treated with curettage and radiotherapy. There is no evidence of recurrence 8 years after treatment. A review of the literature is presented on sacral ependymomas presenting with an osteolytic radiographic appearance (24 cases in 18 reports). The differential diagnosis with other sacral neoplasms is discussed. (orig.)

  5. Osteolytic extra-axial sacral myxopapillary ependymoma.

    Science.gov (United States)

    Biagini, R; Demitri, S; Orsini, U; Bibiloni, J; Briccoli, A; Bertoni, F

    1999-10-01

    The authors report an unusual case of sacral osteolytic myxopapillary ependymoma treated with curettage and radiotherapy. There is no evidence of recurrence 8 years after treatment. A review of the literature is presented on sacral ependymomas presenting with an osteolytic radiographic appearance (24 cases in 18 reports). The differential diagnosis with other sacral neoplasms is discussed.

  6. Osteolytic extra-axial sacral myxopapillary ependymoma

    Energy Technology Data Exchange (ETDEWEB)

    Biagini, R.; Demitri, S.; Orsini, U. [Clinica Ortopedica, Istituto Ortopedico Rizzoli, Bologna (Italy); Bibiloni, J. [Medical Sciences Campus San Juan, University of Puerto Rico (Puerto Rico); Briccoli, A. [Istituto di Patologia Chirurgica, University of Modena (Italy); Bertoni, F. [Servizio di Anatomia Patologica, Istituto Ortopedico Rizzoli Bologna (Italy)

    1999-10-01

    The authors report an unusual case of sacral osteolytic myxopapillary ependymoma treated with curettage and radiotherapy. There is no evidence of recurrence 8 years after treatment. A review of the literature is presented on sacral ependymomas presenting with an osteolytic radiographic appearance (24 cases in 18 reports). The differential diagnosis with other sacral neoplasms is discussed. (orig.)

  7. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  8. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  9. Axial loading cross screw fixation for the Austin bunionectomy.

    Science.gov (United States)

    Rigby, Ryan B; Fallat, Lawrence M; Kish, John P

    2011-01-01

    The Austin procedure has become a common method of osteotomy for the correction of hallux abductovalgus when indicated. The V-type configuration is intrinsically stable but not without complications. One complication encountered is rotation and/or displacement of the capital fragment. We present the use of an axial loading screw in conjunction with a dorsally placed compression screw. The benefit to this technique lies in the orientation of the axial loading screw, because it is directed to resist the ground reactive forces while also providing a second point of fixation in a crossing screw design. In a head-to-head biomechanical comparison, we tested single dorsal screw fixation versus double screw fixation, including both the dorsal and the axial loading screws in 10 metatarsal Sawbones(®) (Pacific Research Laboratories Inc, Vashon, WA). Five metatarsals received single dorsal screw fixation and five received the dorsal screw and the additional axial loading screw. The metatarsals were analyzed on an Instron compression device for comparison; 100% of the single screw fixation osteotomies failed with compression at an average peak load of 205 N. Four of five axial loading double screw fixation osteotomies did not fail. This finding suggests that the addition of an axial loading screw providing cross screw orientation significantly increases the stability of the Austin osteotomy, ultimately decreasing the likelihood of displacement encountered in the surgical repair of hallux abductovalgus. Copyright © 2011 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Reactive control of subsonic axial fan noise in a duct.

    Science.gov (United States)

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical.

  11. Axial design of nuclear fuel using path relinking; Diseno axial de combustible nuclear utilizando path relinking

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, A.; Torres, M.; Ortiz, J. J.; Perusquia, R.; Hernandez, J. L.; Montes, J. L. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: jacm@nuclear.inin.mx

    2008-07-01

    In the present work the preliminary results were obtained with the zoctli system whose purpose is the axial design of assembly of nuclear fuel under certain considerations. For the mentioned design well-know cells were already used and that they have been proven in diverse cycles of operation in the nuclear power plant of Laguna Verde. The design contemplates fuels assemblies of 10x10 and with 2 water channels. The assembly was distributed in 6 axial zones according to its structure. In order to take to end the optimization is was used the well-known technique like Path relinking and to find the group of previous solutions required by this technique uses the technical Taboo search. In order to work with Path relinking, 5 trajectories was taken in to account from a set of 5 previous solutions generated with theTaboo search, the update of the group of solutions is carried out in dynamic form. In the case of the Taboo search it was used a list of variable size, it was implement an aspiration approach, it was used the vector of frequencies and due to the cost of the evaluation of the objective function, only it was review 5% of the vicinity. For the objective function was considered the limit thermal, the axial profile of power, the effective multiplication factor and the margin of having turned off in cold. In order to prove the design system, it was used a balance cycle with a value of reference of 0.9928 for the effective multiplication factor that is equivalent to a produced energy of 10896 MWd/TU at the end of operation to full power. The designed assemblies were placed both in one of lots different from fresh assemblies on which it counts the referred cycle. At the end one a comparison with the results obtained with other techniques and under similar conditions is made. The results obtained until the moment show an appropriate performance of the system. It is possible to indicate that a small inconvenient is the amount of consumed resources of calculation during

  12. Advances in classification, basic mechanisms and clinical science in ankylosing spondylitis and axial spondyloarthritis.

    Science.gov (United States)

    Robinson, P C; Benham, H

    2015-02-01

    The field of spondyloarthritis (SpA) has seen huge advances over the past 5 years. The classification of axial disease has been redefined by the axial SpA criteria that incorporate disease captured before radiographic damage is evident as well as established erosive sacroiliac joint disease. Our knowledge of genetics and basic immunological pathways has progressed significantly. In addition, revolutionary progress has been achieved with the availability of tumour necrosis factor inhibitors for treating patients with moderate to severe disease. In parallel, several of novel biomarkers have been identified that show significant promise for the future. Advances in magnetic resonance imaging have helped define positive disease. We have identified that T1 and short tau inversion recovery sequences are best for the diagnosis of axial SpA, and gadolinium contrast is not additive for diagnosis. Progress has been made in identifying potential agents and strategies that reduce radiographic progression. Several referral strategies aimed at appropriate identification of patients have been trialled and found to be effective. There is still substantial work ahead, but the advances of the last 5 years have made a huge and tangible difference at the clinical coalface, and we suggest that this trend will continue. © 2014 Royal Australasian College of Physicians.

  13. High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix

    CERN Document Server

    Braem, André; Joram, C; Séguinot, Jacques; Weilhammer, P; De Leo, R; Nappi, E; Lustermann, W; Schinzel, D; Johnson, I; Renker, D; Albrecht, S

    2007-01-01

    We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM).

  14. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  15. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... imaging provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  17. Computed Tomography (CT) - Spine

    Science.gov (United States)

    ... the removal of fluid from a localized infection ( abscess ). In patients with narrowing ( stenosis ) of the spine ... Survey Images × Image Gallery Computed Tomography (CT or CAT scan) equipment View full size with caption Do ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  20. Computer tomography in otolaryngology

    Energy Technology Data Exchange (ETDEWEB)

    Gradzki, J. (Akademia Medyczna, Poznan (Poland))

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented.

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of a stroke. a stroke, especially with a new technique called Perfusion CT. brain tumors. enlarged brain ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  3. Informationally incomplete quantum tomography

    Science.gov (United States)

    Teo, Yong Siah; Řeháček, Jaroslav; Hradil, Zdenĕk

    2013-11-01

    In quantum-state tomography on sources with quantum degrees of freedom of large Hilbert spaces, inference of quantum states of light for instance, a complete characterization of the quantum states for these sources is often not feasible owing to limited resources. As such, the concepts of informationally incomplete state estimation becomes important. These concepts are ideal for applications to quantum channel/ process tomography, which typically requires a much larger number of measurement settings for a full characterization of a quantum channel. Some key aspects of both quantumstate and quantum-process tomography are arranged together in the form of a tutorial review article that is catered to students and researchers who are new to the field of quantum tomography, with focus on maximum-likelihood related techniques as instructive examples to illustrate these ideas.

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  5. Intracoronary optical coherence tomography

    DEFF Research Database (Denmark)

    Tenekecioglu, Erhan; Albuquerque, Felipe N; Sotomi, Yohei

    2017-01-01

    By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT)...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  8. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  10. Introduction to Seismic Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Charlotte Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.

  11. STEM tomography for thick biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Kazuhiro [FEI Company Japan Ltd., Application Laboratory, NSS-II Building, 2-13-34 Kohnan, Minato-ku, Tokyo 108-0075 (Japan)], E-mail: kazuhiro.aoyama@fei.com; Takagi, Tomoko [FEI Company Japan Ltd., Application Laboratory, NSS-II Building, 2-13-34 Kohnan, Minato-ku, Tokyo 108-0075 (Japan); Laboratory of Electron Microscopy, Japan Women' s University, 2-8-1 Mejirodai, Bunkyo-ku, Tokyo 112-8681 (Japan); Hirase, Ai; Miyazawa, Atsuo [Bio-multisome Research Team, RIKEN SPring-8 Center, Harima Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan); CREST, JST (Japan)

    2008-12-15

    Scanning transmission electron microscopy (STEM) tomography was applied to biological specimens such as yeast cells, HEK293 cells and primary culture neurons. These cells, which were embedded in a resin, were cut into 1-{mu}m-thick sections. STEM tomography offers several important advantages including: (1) it is effective even for thick specimens, (2) 'dynamic focusing', (3) ease of using an annular dark field (ADF) mode and (4) linear contrasts. It has become evident that STEM tomography offers significant advantages for the observation of thick specimens. By employing STEM tomography, even a 1-{mu}m-thick specimen (which is difficult to observe by conventional transmission electron microscopy (TEM)) was successfully analyzed in three dimensions. The specimen was tilted up to 73 deg. during data acquisition. At a large tilt angle, the specimen thicknesses increase dramatically. In order to observe such thick specimens, we introduced a special small condenser aperture that reduces the collection angle of the STEM probe. The specimen damage caused by the convergent electron beam was expected to be the most serious problem; however, the damage in STEM was actually smaller than that in TEM. In this study, the irradiation damage caused by TEM- and STEM-tomography in biological specimens was quantitatively compared.

  12. In vitro assessment of cone beam local computed tomography for proximal caries detection.

    Science.gov (United States)

    Kalathingal, Sajitha M; Mol, André; Tyndall, Donald A; Caplan, Daniel J

    2007-11-01

    To compare the accuracy of local computed tomography (LCT) and conventional radiography for proximal caries detection and depth assessment. An in vitro model was used consisting of 20 extracted posterior teeth with 18 caries lesions. Local computed tomography slices were reconstructed in axial and parasagittal planes from 100 basis projections. Conventional radiographs were also acquired. Eight observers determined the presence and depth of caries lesions. Receiver operating characteristic analysis and weighted kappa statistics were used. Local computed tomography had a mean A(z) score of 0.82 (SD = 0.07) and conventional radiography of 0.79 (SD = 0.08; analysis of variance: P > .05). Interobserver agreement was moderate. The mean kappa for depth assessment was 0.68 (SD = 0.06) for LCT and 0.47 (SD = 0.08) for conventional radiography (analysis of variance: P proximal caries detection. Local computed tomography was more accurate for assessing caries lesion depth.

  13. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  14. Computed Tomography Imaging of the Topographical Anatomy of Canine Prostate

    International Nuclear Information System (INIS)

    Dimtrox, R.; Yonkova, P.; Vladova, D.; Kostov, D.

    2010-01-01

    AIM: To investigate the topographical anatomy of canine prostate gland by computed tomography (CT) for diagnostic imaging purposes. ÐœATERIAL AND METHODS: Seven clinically healthy mongrel male dogs at the age of 3−4 years and body weight of 10−15 kg were submitted to transverse computerized axial tomography (CAT) with cross section thickness of 5 mm. RESULTS: The CT image of canine prostate is visualized throughout the scans of the pelvis in the planes through the first sacral vertebra (S1) dorsally; the bodies of iliac bones laterally and cranially to the pelvic brim (ventrally). The body of prostate appears as an oval homogenous relatively hypo dense finding with soft tissue density. The gland is well differentiated from the adjacent soft tissues. CONCLUSION: By means of CT, the cranial part of prostate gland in adult dogs aged 3−4 years exhibited an abdominal localization. (author)

  15. Shape Manifestation of Respiration in the Axial System

    Directory of Open Access Journals (Sweden)

    Eliška Slawiková

    2014-07-01

    Full Text Available Shape Manifestation of Respiration in the Axial System The aim of the study was to evaluate the effect of respiration on the shape changes of the axial system. Our approach focuses more on the analysis of respiratory function and their implementation within the complex axial system – the trunk. The results of this pilot study will use as evidence for further study of relationship between respiration and physiotherapy. Now we are looking for an answer to the question, at what level of the human body reflected the influence of respiration and its use in physiotherapy. This pilot study was attended by two women and one man aged 25–40 years, who were not selected for the study according to predetermined conditions. The same characteristic features of all three prarticipants were sedentary job connected with excessive mental strain, occasional low back pain (usually after a long sitting and the absence of acute or chronic respiratory diseases. Another common feature of the participants was the absence of structural changes in the spine. During the experiment was monitored maximum inhalation and maximum exhalation, and respiratory maneuver Kapalabhati, often used as one of the basic yoga breathing exercises. To detect trunk movement during the respiratory maneuver, we opted for a Qualysis – 3D torso topography. At the same time spirometer panned changes in volume over time, both exhaled and inhaled air. The purpose of this study was to assess symptoms and implementation of respiratory maneuvers in the axial system, particularly the chest and abdominal area. During the experiment, we followed the differences in reaction of the chest and abdomen in respiratory maneuver in the direction vertical, antero-posterior and lateral. The difference in these indicators at different phases of the respiratory maneuver confirms our assumption of the possibility of influencing the selected folders axial system through appropriately selected respiratory maneuver

  16. Continuous millennial decrease of the Earth's magnetic axial dipole

    Science.gov (United States)

    Poletti, Wilbor; Biggin, Andrew J.; Trindade, Ricardo I. F.; Hartmann, Gelvam A.; Terra-Nova, Filipe

    2018-01-01

    Since the establishment of direct estimations of the Earth's magnetic field intensity in the first half of the nineteenth century, a continuous decay of the axial dipole component has been observed and variously speculated to be linked to an imminent reversal of the geomagnetic field. Furthermore, indirect estimations from anthropologically made materials and volcanic derivatives suggest that this decrease began significantly earlier than direct measurements have been available. Here, we carefully reassess the available archaeointensity dataset for the last two millennia, and show a good correspondence between direct (observatory/satellite) and indirect (archaeomagnetic) estimates of the axial dipole moment creating, in effect, a proxy to expand our analysis back in time. Our results suggest a continuous linear decay as the most parsimonious long-term description of the axial dipole variation for the last millennium. We thus suggest that a break in the symmetry of axial dipole moment advective sources occurred approximately 1100 years earlier than previously described. In addition, based on the observed dipole secular variation timescale, we speculate that the weakening of the axial dipole may end soon.

  17. Amphiregulin Antibody and Reduction of Axial Elongation in Experimental Myopia

    Directory of Open Access Journals (Sweden)

    Wen Jun Jiang

    2017-03-01

    Full Text Available To examine the mechanism of ocular axial elongation in myopia, guinea pigs (age: 2–3 weeks which either underwent unilateral or bilateral lens-induced myopization (group 1 or which were primarily myopic at baseline (group 2 received unilateral intraocular injections of amphiregulin antibody (doses: 5, 10, or 15 μg three times in intervals of 9 days. A third group of emmetropic guinea pigs got intraocular unilateral injections of amphiregulin (doses: 0.25, 0.50 or 1.00 ng, respectively. In each group, the contralateral eyes received intraocular injections of Ringer's solution. In intra-animal inter-eye comparison and intra-eye follow-up comparison in groups 1 and 2, the study eyes as compared to the contralateral eyes showed a dose-dependent reduction in axial elongation. In group 3, study eyes and control eyes did not differ significantly in axial elongation. Immunohistochemistry revealed amphiregulin labelling at the retinal pigment epithelium in eyes with lens-induced myopization and Ringer's solution injection, but not in eyes with amphiregulin antibody injection. Intraocular injections of amphiregulin-antibody led to a reduction of lens-induced axial myopic elongation and of the physiological eye enlargement in young guinea pigs. In contrast, intraocularly injected amphiregulin in a dose of ≤1 ng did not show a significant effect. Amphiregulin may be one of several essential molecular factors for axial elongation.

  18. Analysis of axial compressive loaded beam under random support excitations

    Science.gov (United States)

    Xiao, Wensheng; Wang, Fengde; Liu, Jian

    2017-12-01

    An analytical procedure to investigate the response spectrum of a uniform Bernoulli-Euler beam with axial compressive load subjected to random support excitations is implemented based on the Mindlin-Goodman method and the mode superposition method in the frequency domain. The random response spectrum of the simply supported beam subjected to white noise excitation and to Pierson-Moskowitz spectrum excitation is investigated, and the characteristics of the response spectrum are further explored. Moreover, the effect of axial compressive load is studied and a method to determine the axial load is proposed. The research results show that the response spectrum mainly consists of the beam's additional displacement response spectrum when the excitation is white noise; however, the quasi-static displacement response spectrum is the main component when the excitation is the Pierson-Moskowitz spectrum. Under white noise excitation, the amplitude of the power spectral density function decreased as the axial compressive load increased, while the frequency band of the vibration response spectrum increased with the increase of axial compressive load.

  19. Development and Testing of an Axial Halbach Magnetic Bearing

    Science.gov (United States)

    Eichenberg, Dennis J.; Gallo, Christopher A.; Thompson, William K.

    2006-01-01

    The NASA Glenn Research Center has developed and tested a revolutionary Axial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic thrust bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Axial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Axial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical systems, computer memory systems, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Axial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability.

  20. Modeling Effects of Axial Extension on Arterial Growth and Remodeling

    Science.gov (United States)

    Valentín, A.; Humphrey, J.D.

    2013-01-01

    Diverse mechanical perturbations elicit arterial growth and remodeling responses that appear to optimize structure and function so as to achieve mechanical homeostasis. For example, it is well known that functional adaptations to sustained changes in transmural pressure and blood flow primarily affect wall thickness and caliber to restore circumferential and wall shear stresses toward normal. More recently, however, it has been shown that changes in axial extension similarly prompt dramatic cell and matrix reorganization and turnover, resulting in marked changes in unloaded geometry and mechanical behavior that presumably restore axial stress toward normal. Because of the inability to infer axial stress from in vivo measurements, simulations are needed to examine this hypothesis and to guide the design of future experiments. In this paper, we show that a constrained mixture model predicts salient features of observed responses to step increases in axial extension, including marked increases in fibrous constituent production, leading to a compensatory lengthening that restores original mechanical behavior. Because axial extension can be modified via diverse surgical procedures, including bypass operations and exploited in tissue regeneration research, there is a need for increased attention to this important aspect of arterial biomechanics and mechanobiology. PMID:19649667

  1. Sagittal reconstruction computed tomography in metrizamide cisternography. Useful diagnostic procedure for malformations in craniovertebral junction and posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, H.; Okita, N.; Fujii, T.; Yoshioka, M.; Saito, H. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1982-08-01

    We studied the sagittal reconstruction technique in computed tomography with metrizamide. Ten ml of metrizamide, 170 mg iodine/ml in concentration, were injected by lumbar puncture. After diffusion of the injected metrizamide, axial computed tomograms were taken by thin slice width (5 mm) with overlapped technique. Then electrical sagittal reconstruction was carried out by optioned software. Injection of metrizamide, non-ionic water soluble contrast media, made clear contrasts among bone, brain parenchyma and cerebrospinal fluid with computed tomography. Sagittal reconstruction technique could reveal more precise details and accurate anatomical relations than ordinary axial computed tomography. This technique was applied on 3 cases (Arnold-Chiari malformation, large cisterna magna and partial agenesis cerebellar vermis), which demonstrated a useful diagnostic procedure for abnormalities of craniovertebral junction and posterior fossa. The adverse reactions of metrizamide were negligible in our series.

  2. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  3. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  4. Thermocapillary Convection in Floating Zone with Axial Magnetic Fields

    Science.gov (United States)

    Liang, Ruquan; Yang, Shuo; Li, Jizhao

    2014-02-01

    Numerical simulations on the effects of axial magnetic fields on the thermocapillary convection in a liquid bridge of silicone-oil-based ferrofluid under zero gravity have been conducted. The Navier-Stokes equations coupled with the energy conservation equation are solved on a staggered grid, and the mass conserving level set approach is used to capture the free surface deformation of the liquid bridge. The obvious effects of the magnetic fields on the flow pattern as well as the velocity and temperature distributions in the liquid bridge can be detected. The axial magnetic fields suppress the thermocapillary convection and a stagnant flow zone is formed between the circulating flow and the symmetric axis as the magnetic fields increase. The axial magnetic fields affect not only the velocity level inside the liquid bridge but also the velocity level on the free surface. The temperature contours near the free surface illustrates conduction-type temperature profiles at moderate strength fields.

  5. Ball Screw Actuator Including an Axial Soft Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Forrest, Steven Talbert (Inventor); Abel, Steve (Inventor); Woessner, George (Inventor); Hanlon, Casey (Inventor)

    2016-01-01

    An actuator includes an actuator housing, a ball screw, and an axial soft stop assembly. The ball screw extends through the actuator housing and has a first end and a second end. The ball screw is coupled to receive a drive force and is configured, upon receipt of the drive force, to selectively move in a retract direction and an extend direction. The axial soft stop assembly is disposed within the actuator housing. The axial soft stop assembly is configured to be selectively engaged by the ball screw and, upon being engaged thereby, to translate, with compliance, a predetermined distance in the extend direction, and to prevent further movement of the ball screw upon translating the predetermined distance.

  6. Improvement of axial power distribution synthesis methodology in CPC

    International Nuclear Information System (INIS)

    Kim, H. H.; Gee, S. G.;; Kim, Y. B.; In, W. K.

    2003-01-01

    The capability of axial power distribution synthesis in CPC plays an important role in determining the DNBR and LPD trip caused by CPC. The axial power distribution is synthesized using the cubic spline function based on the three excore detector signals. The axial power distributions are categorized into 8 function sets and each sets are stored as pre-calculated values in CPC to save the calculation time. In this study, the additional function sets, the real break-point function sets and the polynomial function are suggested to evaluate the possibility of improving the synthesis capability in CPC. In addition, RMS errors are compared and evaluated for each synthesis method. As a result, it was confirmed that the function sets stored in CPC were not optimal. The analysis result showed that RMS error could be reduced by selecting the proper function sets suggested in this study

  7. Axially modulated arch resonator for logic and memory applications

    KAUST Repository

    Hafiz, Md Abdullah Al

    2018-01-17

    We demonstrate reconfigurable logic and random access memory devices based on an axially modulated clamped-guided arch resonator. The device is electrostatically actuated and the motional signal is capacitively sensed, while the resonance frequency is modulated through an axial electrostatic force from the guided side of the microbeam. A multi-physics finite element model is used to verify the effectiveness of the axial modulation. We present two case studies: first, a reconfigurable two-input logic gate based on the linear resonance frequency modulation, and second, a memory element based on the hysteretic frequency response of the resonator working in the nonlinear regime. The energy consumptions of the device for both logic and memory operations are in the range of picojoules, promising for energy efficient alternative computing paradigm.

  8. Program for beam optical computation of axial symmetrical electrostatic systems

    International Nuclear Information System (INIS)

    Ke Jianlin; Wu Chunlei; Zhou Changgeng

    2012-01-01

    The beam optical computation of axial symmetrical electrostatic systems is very important in the design and test of low-energy accelerators such as Cock-Croft and Van de Graaf accelerators. In this paper, a program for the beam optical computation of these structures has been developed using transfer matrix method. The electrostatic field region is divided into several small intervals in the program, and then the beam envelope is calculated interval-to-interval from the axial potential distribution, which is calculated by other electromagnetic field simulation software such as Maxwell SV. Space charge effect is included so that the program can be used in the computation of intense beam, while nonlinear effect is beyond its ability. The program can be used in the calculation of beam optics in most complicated axial symmetrical electrostatic fields, and the computing time required is very short. (authors)

  9. Progressive atlanto-axial subluxation in Behcet's disease

    International Nuclear Information System (INIS)

    Kim, Sang-hyuk; Eoh, Whan

    2010-01-01

    Behcet's disease is a chronic inflammatory condition involving several organs, such as the skin, mucous membranes, eyes, joints, intestines, lungs and central nervous system. It rarely affects the spinal column. We describe a case of progressive atlanto-axial subluxation in a 44-year-old woman with Behcet's disease. The patient started complaining of posterior neck pain 10 years after the diagnosis of her Behcet's disease. Initial radiographs showed no abnormal finding, but follow-up radiographs 6 month later demonstrated atlanto-axial subluxation. To the best of our knowledge, this is the second reported case in the worldwide literature of an atlanto-axial instability in a patient with Behcet's disease. (orig.)

  10. Bifurcation and chaos of an axially accelerating viscoelastic beam

    International Nuclear Information System (INIS)

    Yang Xiaodong; Chen Liqun

    2005-01-01

    This paper investigates bifurcation and chaos of an axially accelerating viscoelastic beam. The Kelvin-Voigt model is adopted to constitute the material of the beam. Lagrangian strain is used to account for the beam's geometric nonlinearity. The nonlinear partial-differential equation governing transverse motion of the beam is derived from the Newton second law. The Galerkin method is applied to truncate the governing equation into a set of ordinary differential equations. By use of the Poincare map, the dynamical behavior is identified based on the numerical solutions of the ordinary differential equations. The bifurcation diagrams are presented in the case that the mean axial speed, the amplitude of speed fluctuation and the dynamic viscoelasticity is respectively varied while other parameters are fixed. The Lyapunov exponent is calculated to identify chaos. From numerical simulations, it is indicated that the periodic, quasi-periodic and chaotic motions occur in the transverse vibrations of the axially accelerating viscoelastic beam

  11. An appraisal of golimumab in the treatment of severe, active nonradiographic axial spondyloarthritis

    Directory of Open Access Journals (Sweden)

    Paccou J

    2016-07-01

    Full Text Available Julien Paccou, René-Marc Flipo Department of Rheumatology, Lille University Hospital, Lille, France Abstract: Golimumab (Simponi® is a fully human tumor necrosis factor α inhibitor (TNFi antibody administered subcutaneously. In the European Union, golimumab is indicated for the treatment of adults with severe, active axial spondyloarthritis (axSpA, which includes both ankylosing spondylitis (AS and nonradiographic axSpA (nr-axSpA. In the US, it is indicated for the treatment of adults with active AS only. This article reviews the efficacy and tolerability of golimumab in nr-axSpA patients compared to other TNFi agents (adalimumab, infliximab, etanercept, and certolizumab pegol. In one ongoing, well-designed controlled study (GO-AHEAD, data at 16 weeks showed that treatment with golimumab (50 mg every 4 weeks was effective in improving the clinical signs and symptoms of disease in nr-axSpA patients. In addition, 16 weeks of treatment with golimumab reduced inflammation in the sacroiliac joints and spine in patients with nr-axSpA. Moreover, objective evidence of active inflammation at baseline, such as a positive magnetic resonance imaging scan and/or an elevated CRP level, was a good predictor of treatment response to golimumab. Golimumab was generally well tolerated in this study, with a tolerability profile consistent with that seen in previous clinical trials for other indications. Although additional long-term data are needed, current evidence indicates that golimumab is an effective option for the treatment of nr-axSpA. However, in the absence of comparative head-to-head trials, there is no recommended hierarchy for the first prescription of a TNFi agent for the treatment of either nr-axSpA or AS. Keywords: axial spondyloarthritis, nonradiographic axial spondyloarthritis, ankylosing spondylitis, golimumab, tumor necrosis factor α inhibitor, therapy

  12. Integrated positron emission tomography/computed tomography for ...

    African Journals Online (AJOL)

    Integrated positron emission tomography/computed tomography for evaluation of mediastinal lymph node staging of non-small-cell lung cancer in a tuberculosisendemic area: A 5-year prospective observational study.

  13. Reducing gait speed affects axial coordination of walking turns.

    Science.gov (United States)

    Forsell, Caroline; Conradsson, David; Paquette, Caroline; Franzén, Erika

    2017-05-01

    Turning is a common feature of daily life and dynamic coordination of the axial body segments is a cornerstone for safe and efficient turning. Although slow walking speed is a common trait of old age and neurological disorders, little is known about the effect of walking speed on axial coordination during walking turns. The aim of this study was to investigate the influence of walking speed on axial coordination during walking turns in healthy elderly adults. Seventeen healthy elderly adults randomly performed 180° left and right turns while walking in their self-selected comfortable pace and in a slow pace speed. Turning velocity, spatiotemporal gait parameters (step length and step time), angular rotations and angular velocity of the head and pelvis, head-pelvis separation (i.e. the angular difference in degrees between the rotation of the head and pelvis) and head-pelvis velocity were analyzed using Wilcoxon signed-rank tests. During slow walking, turning velocity was 15% lower accompanied by shorter step length and longer step time compared to comfortable walking. Reducing walking speed also led to a decrease in the amplitude and velocity of the axial rotation of the head and pelvis as well as a reduced head-pelvis separation and angular velocity. This study demonstrates that axial coordination during turning is speed dependent as evidenced by a more 'en bloc' movement pattern (i.e. less separation between axial segments) at reduced speeds in healthy older adults. This emphasizes the need for matching speed when comparing groups with diverse walking speeds to differentiate changes due to speed from changes due to disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. [Myopia: frequency of lattice degeneration and axial length].

    Science.gov (United States)

    Martín Sánchez, M D; Roldán Pallarés, M

    2001-05-01

    To evaluate the relationship between lattice retinal degeneration and axial length of the eye in different grades of myopia. A sample of 200 eyes from 124 myopic patients was collected by chance. The average age was 34.8 years (20-50 years) and the myopia was between 0.5 and 20 diopters (D). The eyes were grouped according to the degree of refraction defect, the mean axial length of each group (Scan A) and the frequency of lattice retinal degeneration and the relationship between these variables was studied. The possible influence of age on our results was also considered. For the statistical analysis, the SAS 6.07 program with the variance analysis for quantitative variables, and chi(2) test for qualitative variables with a 5% significance were used. A multivariable linear regression model was also adjusted. The highest frequency of lattice retinal degeneration occurred in those myopia patients having more than 15 D, and also in the group of myopia patients between 3 and 6 D, but this did not show statistical significance when compared with the other myopic groups. If the axial length is assessed, a greater frequency of lattice retinal degeneration is also found when the axial length is 25-27 mm and 29-30 mm, which correspond, respectively, to myopias between 3-10 D and more than 15 D. When the multivariable linear regression model was adjusted, the axial length showed the existence of lattice retinal degeneration (beta 0.41 mm; p=0.08) adjusted by the number of diopters (beta 0.38 mm; plattice retinal degeneration was found for myopias with axial eye length between 29-30 mm (more than 15 D), and 25-27 mm (between 3-10 D).

  15. Correction of distortions in optical coherence tomography imaging of the eye

    International Nuclear Information System (INIS)

    Podoleanu, Adrian; Charalambous, Ismini; Plesea, Lucian; Dogariu, Aristide; Rosen, Richard

    2004-01-01

    Optical coherence tomography (OCT) images are affected by artefacts. These artefacts are the result of different factors such as refraction, curvature of the intermediate layers up to the depth of interest and the scanning procedure. The effect of such errors is different, depending on the way the image is acquired, either en-face or longitudinal OCT. We quantify the distortions by evaluating a lateral and an axial error. These measure the lateral and axial deviations of each image point from the object point inside the tissue. We show that the axial distortion can be larger than the achievable depth resolution in modern OCT systems. We have investigated these errors in imaging different tissue: cornea and retina in vivo and an intraocular lens in vitro

  16. Ocean acoustic reverberation tomography.

    Science.gov (United States)

    Dunn, Robert A

    2015-12-01

    Seismic wide-angle imaging using ship-towed acoustic sources and networks of ocean bottom seismographs is a common technique for exploring earth structure beneath the oceans. In these studies, the recorded data are dominated by acoustic waves propagating as reverberations in the water column. For surveys with a small receiver spacing (e.g., ocean acoustic reverberation tomography, is developed that uses the travel times of direct and reflected waves to image ocean acoustic structure. Reverberation tomography offers an alternative approach for determining the structure of the oceans and advancing the understanding of ocean heat content and mixing processes. The technique has the potential for revealing small-scale ocean thermal structure over the entire vertical height of the water column and along long survey profiles or across three-dimensional volumes of the ocean. For realistic experimental geometries and data noise levels, the method can produce images of ocean sound speed on a smaller scale than traditional acoustic tomography.

  17. Practical Bayesian tomography

    Science.gov (United States)

    Granade, Christopher; Combes, Joshua; Cory, D. G.

    2016-03-01

    In recent years, Bayesian methods have been proposed as a solution to a wide range of issues in quantum state and process tomography. State-of-the-art Bayesian tomography solutions suffer from three problems: numerical intractability, a lack of informative prior distributions, and an inability to track time-dependent processes. Here, we address all three problems. First, we use modern statistical methods, as pioneered by Huszár and Houlsby (2012 Phys. Rev. A 85 052120) and by Ferrie (2014 New J. Phys. 16 093035), to make Bayesian tomography numerically tractable. Our approach allows for practical computation of Bayesian point and region estimators for quantum states and channels. Second, we propose the first priors on quantum states and channels that allow for including useful experimental insight. Finally, we develop a method that allows tracking of time-dependent states and estimates the drift and diffusion processes affecting a state. We provide source code and animated visual examples for our methods.

  18. Fluoroscopic lumbar interlaminar epidural injections in managing chronic lumbar axial or discogenic pain

    Directory of Open Access Journals (Sweden)

    Manchikanti L

    2012-08-01

    Full Text Available Laxmaiah Manchikanti,1,2 Kimberly A Cash,1 Carla D McManus,1 Vidyasagar Pampati,1 Ramsin Benyamin3,41Pain Management Center of Paducah, Paducah, KY; 2University of Louisville, Louisville, KY; 3Millennium Pain Center, Bloomington, IL; 4University of Illinois, Urbana-Champaign, IL, USAAbstract: Among the multiple causes of chronic low back pain, axial and discogenic pain are common. Various modalities of treatments are utilized in managing discogenic and axial low back pain including epidural injections. However, there is a paucity of evidence regarding the effectiveness, indications, and medical necessity of any treatment modality utilized for managing axial or discogenic pain, including epidural injections. In an interventional pain management practice in the US, a randomized, double-blind, active control trial was conducted. The objective was to assess the effectiveness of lumbar interlaminar epidural injections of local anesthetic with or without steroids for managing chronic low back pain of discogenic origin. However, disc herniation, radiculitis, facet joint pain, or sacroiliac joint pain were excluded. Two groups of patients were studied, with 60 patients in each group receiving either local anesthetic only or local anesthetic mixed with non-particulate betamethasone. Primary outcome measures included the pain relief-assessed by numeric rating scale of pain and functional status assessed by the, Oswestry Disability Index, Secondary outcome measurements included employment status, and opioid intake. Significant improvement or success was defined as at least a 50% decrease in pain and disability. Significant improvement was seen in 77% of the patients in Group I and 67% of the patients in Group II. In the successful groups (those with at least 3 weeks of relief with the first two procedures, the improvement was 84% in Group I and 71% in Group II. For those with chronic function-limiting low back pain refractory to conservative management

  19. Manufacture of axially insulated large-area diodes

    International Nuclear Information System (INIS)

    Ma Weiyi; Zhou Kungang; Wang Youtian; Zhang Dong; Shan Yusheng; Wang Naiyan

    1999-01-01

    The author describes the design and construction of the axially insulated large-area diodes used in the 'Heaven-1'. The four axially insulated large-area diodes are connected to the 10 ohm pulse transmission lines via the vacuum feed through tubes. The experimental results with the diodes are given. The diodes can steadily work at the voltage of 650 kV, and the diode current density is about 80 A per cm 2 with a pulse width of 220 ns. The electron beams with a total energy of 25 kJ are obtained

  20. Periodicity effects of axial waves in elastic compound rods

    DEFF Research Database (Denmark)

    Nielsen, R. B.; Sorokin, S. V.

    2015-01-01

    Floquet analysis is applied to the Bernoulli-Euler model for axial waves in a periodic rod. Explicit asymptotic formulae for the stop band borders are given and the topology of the stop band pattern is explained. Eigenfrequencies of the symmetric unit cell are determined by the Phase-closure Prin......Floquet analysis is applied to the Bernoulli-Euler model for axial waves in a periodic rod. Explicit asymptotic formulae for the stop band borders are given and the topology of the stop band pattern is explained. Eigenfrequencies of the symmetric unit cell are determined by the Phase...

  1. Buckling localization in a cylindrical panel under axial compression

    DEFF Research Database (Denmark)

    Tvergaard, Viggo; Needleman, A.

    2000-01-01

    Localization of an initially periodic buckling pattern is investigated for an axially compressed elastic-plastic cylindrical panel of the type occurring between axial stiffeners on cylindrical shells. The phenomenon of buckling localization and its analogy with plastic flow localization in tensile...... test specimens is discussed in general. For the cylindrical panel, it is shown that buckling localization develops shortly after a maximum load has been attained, and this occurs for a purely elastic panel as well as for elastic-plastic panels. In a case where localization occurs after a load maximum...

  2. Spectral analysis in thin tubes with axial heterogeneities

    KAUST Repository

    Ferreira, Rita

    2015-01-01

    In this paper, we present the 3D-1D asymptotic analysis of the Dirichlet spectral problem associated with an elliptic operator with axial periodic heterogeneities. We extend to the 3D-1D case previous 3D-2D results (see [10]) and we analyze the special case where the scale of thickness is much smaller than the scale of the heterogeneities and the planar coefficient has a unique global minimum in the periodic cell. These results are of great relevance in the comprehension of the wave propagation in nanowires showing axial heterogeneities (see [17]).

  3. A simple approach to the ABJ axial anomaly

    International Nuclear Information System (INIS)

    Horejsi, J.

    1985-01-01

    A very simple semi-quantitative derivation of the Adler-Bell-Jackiw (ABJ) axial anomaly is given, based on an investigation of the absorptive part of the VVA triangle graph and dispersion relations. Essential ingredients of our discussion are: normal Ward identities for the absorptive part of the relevant diagram, dimensional analysis, unitarity, and energy-momentum conservation. An explanation of the physical origin of axial anomaly, proposed in some earlier treatments within such a dispersive framework, is critically examined. In particular, the interpretation of the ABJ anomaly as an analogy of the Lee-Nauenberg effect occurring in the massless limit of spinor electrodynamics is shown to be fallacious

  4. Light-front view of the axial anomaly

    International Nuclear Information System (INIS)

    Ji, C.; Rey, S.

    1996-01-01

    Motivated by an apparent puzzle of the light-front vacua incompatible with the axial anomaly, we have considered the two-dimensional massless Schwinger model for an arbitrary interpolating angle of Hornbostel close-quote s interpolating quantization surface. By examining spectral deformation of the Dirac sea under an external electric field semiclassically, we have found that the axial anomaly is quantization angle independent. This indicates an intricate nontrivial vacuum structure present even in the light-front limit. copyright 1996 The American Physical Society

  5. Study on Predicting Axial Load Capacity of CFST Columns

    Science.gov (United States)

    Ravi Kumar, H.; Muthu, K. U.; Kumar, N. S.

    2017-11-01

    This work presents an analytical study and experimental study on the behaviour and ultimate load carrying capacity of axially compressed self-compacting concrete-filled steel tubular columns. Results of tests conducted by various researchers on 213 samples concrete-filled steel tubular columns are reported and present authors experimental data are reported. Two theoretical equations were derived for the prediction of the ultimate axial load strength of concrete-filled steel tubular columns. The results from prediction were compared with the experimental data. Validation to the experimental results was made.

  6. Computed tomographic myelography (CTM) in atlanto-axial rheumatoid arthritis

    International Nuclear Information System (INIS)

    Laasonen, E.M.; Servo, A.; Kankaanpaeae, U.; Paukku, P.; Sandelin, J.; Slaetis, P.

    1985-01-01

    Thirty-two patients with severe cervical rheumatoid arthritis were investigated preoperatively with cervical myelography (CeM) and computed tomographic myelography (CTM). The severity of their clinical symptoms correlated excellently with a combination of the deformation of the spinal cord at the atlanto-axial level, the lateral dislocation of the cord at the same level, and the deformation of the cord at some lower cervical level. Obstructing softtissue excrescences seemed to have little value. No correlation was found in this study between the deformation of the cord and the main findings of the plain films: the atlanto-axial subluxation (AAS), the vertical subluxation (VS), or their combination. (orig.)

  7. Digital multilayer tomography

    International Nuclear Information System (INIS)

    Dueber, C.; Klose, K.J.; Thelen, M.

    1991-01-01

    With digital multilayer tomography a sequence of projection images is recorded by an image intensifier television system and stored as digital data during a linear run of a layer sequence. Using this data record, tomograms of the examined body region can be computed for any layer thickness by shifts and superimposition of the single projections later at a digital workstation. The qualities of digital and conventional tomograms are basically comparable. A drawback of digital tomography is its lower local resolution (512 x 512 image matrix), advantages are a lower radiation exposure, a shorter patient examination time, and the facilities of digital image processing (later processing, archive setup, transmission). (orig.) [de

  8. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  9. High resolution computed tomography of the inferior alveolar and lingual nerves

    International Nuclear Information System (INIS)

    Feifel, H.; Riediger, D.; Gustorf-Aeckerle, R.

    1994-01-01

    Coronal and axial high resolution computed tomography of the mandible extends facilities in dentoalveolar surgery. Preoperatively the relationship between the mandibular canal and the roots of deeply displaced third molars can be determined precisely. After surgical removal of lower wisdom teeth iatrogenic defects of the lingual cortical bone can be detected. The additional information obtained when compared with conventional radiographs is demonstrated in case descriptions. Indications for this technique, radiation exposure and implications for surgery are discussed. (orig.)

  10. Diagnostic scope of computer tomography in hip disease - Paget's disease, femoral head necrosis, coxarthrosis, coxarthritis

    International Nuclear Information System (INIS)

    Nebel, G.; Lingg, G.; Reid, W.

    1982-01-01

    The value of computer tomography was investigated in Paget's disease of the hip, femoral head necrosis (adult avascular and osteoradionecrosis), coxarthrosis and coxarthritis (bacterial and rheumatoid). The greatest value of CT is in the diagnosis of adult avascular necrosis of the femoral head and is valuable for localising the necrotic area in the axial plane. This is of value in planning surgical treatment (displacement osteotomy or endoprosthesis). In Paget's disease, coxarthrosis and coxarthritis, CT provides only additional or more precise information. (orig.) [de

  11. Lateral resonant Doppler flow measurement by spectral domain optical coherence tomography

    Science.gov (United States)

    Walther, Julia; Koch, Edmund

    2017-07-01

    In spectral domain optical coherence tomography (SD-OCT), any transverse motion component of a detected obliquely moving sample results in a nonlinear relationship between the Doppler phase shift and the axial sample velocity restricting phase-resolved Doppler OCT. To circumvent the limitation, we propose the lateral resonant Doppler flow quantification in spectral domain OCT, where the scanner movement velocity is matched to the transverse velocity component of the sample motion.

  12. In vivo visualization of photoreceptor layer and lipofuscin accumulation in Stargardt’s disease and fundus flavimaculatus by high resolution spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Giuseppe Querques

    2009-12-01

    Full Text Available Giuseppe Querques, Rosy Prato, Gabriel Coscas, Gisèle Soubrane, Eric H SouiedDepartment of Ophthalmology, Hopital Intercommunal de Creteil, University Paris XII, FranceIntroduction: To assess photoreceptor (PR layer morphology in patients with Stargardt’s disease (STGD and fundus flavimaculatus (FFM using high resolution spectral domain optical coherence tomography (HD-OCT; OCT 4000 Cirrus, Humphrey-Zeiss, San Leandro, CA.Methods: This was a prospective observational case series. Sixteen consecutive patients with STGD and FFM underwent a complete ophthalmologic examination. Optical coherence tomography examination was performed with HD-OCT, a high-speed (27,000 axial scans per second OCT system using spectral/Fourier domain detection, with an axial image resolution of 5 µm.Results: A total of 31 eyes were included in the study. Transverse loss of the PR layer in the foveal region was shown by HD-OCT. Twenty eyes with clinically evident central atrophy had a disruption of either the Verhoeff‘s membrane (VM or the layer corresponding to the interface of inner segment (IS and outer segment (OS of PR in the foveal region. Among these eyes, 12/20 eyes had a loss of the PR layer (loss of both VM and IS-OS interface in the foveal region. Eleven eyes (11/31 without clinically evident central atrophy had an intact interface of IS and OS of PR centrally. Moreover, we observed hyperreflective deposits: type 1 lesions located within the retinal pigment epithelium (RPE layer and at the level of the outer segments of PR, and type 2 lesions located at the level of the outer nuclear layer and clearly separated from the RPE layer. Type 1 lesions alone were associated with absence of loss of the PR layer in the foveal region in all eyes; type 2 lesions were always associated with presence of type 1 lesions, and often (8/12 eyes associated with loss of the PR layer within the foveal region. Mean best-corrected visual acuity (BCVA was significantly

  13. The evolutionary origin of the turtle shell and its dependence on the axial arrest of the embryonic rib cage.

    Science.gov (United States)

    Hirasawa, Tatsuya; Pascual-Anaya, Juan; Kamezaki, Naoki; Taniguchi, Mari; Mine, Kanako; Kuratani, Shigeru

    2015-05-01

    Turtles are characterized by their possession of a shell with dorsal and ventral moieties: the carapace and the plastron, respectively. In this review, we try to provide answers to the question of the evolutionary origin of the carapace, by revising morphological, developmental, and paleontological comparative analyses. The turtle carapace is formed through modification of the thoracic ribs and vertebrae, which undergo extensive ossification to form a solid bony structure. Except for peripheral dermal elements, there are no signs of exoskeletal components ontogenetically added to the costal and neural bones, and thus the carapace is predominantly of endoskeletal nature. Due to the axial arrest of turtle rib growth, the axial part of the embryo expands laterally and the shoulder girdle becomes encapsulated in the rib cage, together with the inward folding of the lateral body wall in the late phase of embryogenesis. Along the line of this folding develops a ridge called the carapacial ridge (CR), a turtle-specific embryonic structure. The CR functions in the marginal growth of the carapacial primordium, in which Wnt signaling pathway might play a crucial role. Both paleontological and genomic evidence suggest that the axial arrest is the first step toward acquisition of the turtle body plan, which is estimated to have taken place after the divergence of a clade including turtles from archosaurs. The developmental relationship between the CR and the axial arrest remains a central issue to be solved in future. © 2014 Wiley Periodicals, Inc.

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  16. Nanometer resolution optical coherence tomography using broad bandwidth XUV and soft x-ray radiation

    Science.gov (United States)

    Fuchs, Silvio; Rödel, Christian; Blinne, Alexander; Zastrau, Ulf; Wünsche, Martin; Hilbert, Vinzenz; Glaser, Leif; Viefhaus, Jens; Frumker, Eugene; Corkum, Paul; Förster, Eckhart; Paulus, Gerhard G.

    2016-01-01

    Optical coherence tomography (OCT) is a non-invasive technique for cross-sectional imaging. It is particularly advantageous for applications where conventional microscopy is not able to image deeper layers of samples in a reasonable time, e.g. in fast moving, deeper lying structures. However, at infrared and optical wavelengths, which are commonly used, the axial resolution of OCT is limited to about 1 μm, even if the bandwidth of the light covers a wide spectral range. Here, we present extreme ultraviolet coherence tomography (XCT) and thus introduce a new technique for non-invasive cross-sectional imaging of nanometer structures. XCT exploits the nanometerscale coherence lengths corresponding to the spectral transmission windows of, e.g., silicon samples. The axial resolution of coherence tomography is thus improved from micrometers to a few nanometers. Tomographic imaging with an axial resolution better than 18 nm is demonstrated for layer-type nanostructures buried in a silicon substrate. Using wavelengths in the water transmission window, nanometer-scale layers of platinum are retrieved with a resolution better than 8 nm. XCT as a nondestructive method for sub-surface tomographic imaging holds promise for several applications in semiconductor metrology and imaging in the water window. PMID:26860894

  17. Redesigning axial-axial (biaxial) cruciform specimens for very high cycle fatigue ultrasonic testing machines.

    Science.gov (United States)

    Montalvão, Diogo; Wren, Andrew

    2017-11-01

    The necessity to increase performances in terms of lifetime and security in mechanical components or structures is the motivation for intense research in fatigue. Applications range from aeronautics to medical devices. With the development of new materials, there is no longer a fatigue limit in the classical sense, where it was accepted that the fatigue limit is the stress level such that there is no fracture up to 1E7 cycles. The recent development of ultrasonic testing machines where frequencies can go as high as 20 kHz or over enabled tests to be extended to ranges larger than 1E9 in just a few days. This area of studies is now known as Very High Cycle Fatigue (VHCF). On the other hand, most of the existing test equipment in the market for both classical and VHCF are uniaxial test machines. However, critical components used in Engineering applications are usually subjected to complex multi-axial loading conditions. In this paper, it is presented the methodology to redesigning existing cruciform test specimens that can be used to create an in-plane biaxial state of stress when used in 'uniaxial' VHCF ultrasonic testing machines (in this case, the term 'uniaxial' is used not because of the state of stress created at the centre of the specimen, but because of the direction at which the load is applied). The methodology is explained in such a way that it can be expanded to other existing designs, namely cruciform designs, that are not yet used in VHCF. Also, although the approach is presented in simple and logical terms, it may not be that obvious for those who have a more focused approach on fatigue rather than on modal analysis. It is expected that by contributing to bridging the gap between the sciences of modal analysis and fatigue, this research will help and encourage others exploiting new capabilities in VHCF.

  18. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  1. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  2. Geodetic SAR Tomography

    NARCIS (Netherlands)

    Zhu, Xiao Xiang; Montazeri, Sina; Gisinger, Christoph; Hanssen, R.F.; Bamler, Richard

    2016-01-01

    In this paper, we propose a framework referred to as 'geodetic synthetic aperture radar (SAR) tomography' that fuses the SAR imaging geodesy and tomographic SAR inversion (TomoSAR) approaches to obtain absolute 3-D positions of a large amount of natural scatterers. The methodology is applied on

  3. Advances in neutron tomography

    Indian Academy of Sciences (India)

    Up to now the interaction of the neutron spin with magnetic fields in samples has not been applied to imaging techniques despite the fact that it was proposed many years ago. About ten years ago neutron depolarization as imaging signal for neutron radiography or tomography was demonstrated and in principle it works.

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  6. Optical Tomography in Combustion

    DEFF Research Database (Denmark)

    Evseev, Vadim

    . JQSRT 113 (2012) 2222, 10.1016/j.jqsrt.2012.07.015] included in the PhD thesis as an attachment. The knowledge and experience gained in the PhD project is the first important step towards introducing the advanced optical tomography methods of combustion diagnostics developed in the project to future...

  7. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Andersen, Peter E.

    2015-01-01

    Optical coherence tomography (OCT) is a noninvasive imaging technique that provides real-time two- and three-dimensional images of scattering samples with micrometer resolution. Mapping the local reflectivity, OCT visualizes the morphology of the sample, in real time or at video rate. In addition...

  8. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  9. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  10. Holography and tomography

    International Nuclear Information System (INIS)

    Howells, M.

    1997-01-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography

  11. Supersymmetric axial anomalies and the Wess-Zumino action

    International Nuclear Information System (INIS)

    Harada, K.; Shizuya, K.

    1988-01-01

    We derive, by an algebraic method, a manifestly supersymmetric extension of Bardeen's minimal form of axial anomalies, which obeys the Wess-Zumino consistency condition. The left-right symmetric form of the anomalies is also obtained by a reduction procedure. We construct the supersymmetric Wess-Zumino effective action and study its low-energy features. (orig.)

  12. Dynamic Response of Axially Loaded Euler-Bernoulli Beams

    DEFF Research Database (Denmark)

    Bayat, M.; Barari, Amin; Shahidi, M.

    2011-01-01

    The current research deals with application of a new analytical technique called Energy Balance Method (EBM) for a nonlinear problem. Energy Balance Method is used to obtain the analytical solution for nonlinear vibration behavior of Euler-Bernoulli beams subjected to axial loads. Analytical...

  13. Axial Torsion of Gangrenous Meckel's Diverticulum Causing Small ...

    African Journals Online (AJOL)

    dividing the band. Resection and anastomosis of the small bowel including the MD was performed. We hereby report a rare and unusual complication of a MD. Although treatment outcome is generally good, pre-operative diagnosis is often difficult. Key words: Axial torsion, Meckel's diverticulum, small bowel obstruction.

  14. A cylindrical drift chamber with azimuthal and axial position readout

    Energy Technology Data Exchange (ETDEWEB)

    Bar-Yam, Z.; Cummings, J.P.; Dowd, J.P.; Eugenio, P.; Hayek, M.; Kern, W.; King, E.; Shenhav, N.; Chung, S.U.; Hackenburg, R.W.; Olchanski, C.; Weygand, D.P.; Willutzki, H.J.; Brabson, B.B.; Crittenden, R.R.; Dzierba, A.R.; Gunter, J.; Lindenbusch, R.; Rust, D.R.; Scott, E.; Smith, P.T.; Sulanke, T.; Teige, S.; Denisov, S.; Dushkin, A.; Kochetkov, V.; Lipaev, V.; Popov, A.; Shein, I.; Soldatov, A.; Anoshina, E.V.; Bodyagin, V.A.; Demianov, A.I.; Gribushin, A.M.; Kodolova, O.L.; Korotkikh, V.L.; Kostin, M.A.; Ostrovidov, A.I.; Sarycheva, L.I.; Sinev, N.B.; Vardanyan, I.N.; Yershov, A.A.; Adams, T.; Bishop, J.M.; Cason, N.M.; Sanjari, A.H.; LoSecco, J.M.; Manak, J.J.; Shephard, W.D.; Stienike, D.L.; Taegar, S.A.; Thompson, D.R.; Brown, D.S.; Pedlar, T.; Seth, K.K.; Wise, J.; Zhao, D.; Adams, G.S.; Napolitano, J.; Nozar, M.; Smith, J.A.; Witkowski, M. [Massachusetts Univ., North Dartmouth, MA (United States)]|[Brookhaven National Laboratory, Upton, L.I., NY 11973 (United States)]|[Indiana University, Bloomington, IN 47405 (United States)]|[Institute for High Energy Physics, Protvino (Russian Federation)]|[Institute of Nuclear Physics, Moscow State University, Moscow (Russian Federation)]|[University of Notre Dame, Notre Dame, IN 46556 (United States)]|[Northwestern University, Evanston, IL 60208 (United States)]|[Rensselaer Polytechnic Institute, Troy, NY 12180 (United States)

    1997-02-21

    A cylindrical multiwire drift chamber with axial charge-division has been constructed and used in experiment E852 at Brookhaven National Laboratory. It serves as a trigger element and as a tracking device for recoil protons in {pi}{sup -}p interactions. We describe the chamber`s design considerations, details of its construction, electronics, and performance characteristics. (orig.).

  15. Studi Regangan Axial dan Lateral pada Tanah Ekspansif

    Directory of Open Access Journals (Sweden)

    Lisa Fitriyana

    2017-07-01

    Full Text Available Swelling and shrinkage abilities of soils are dangerous for buildings. According to Hardiyatmo (2014 There are two types of swelling in expansive soils that are the movement of lateral (horizontal and axial (vertical. Oftentimes the deformation of soils cannot be supported by building stiffness. This damage can be seen in retaining walls, tunnel walls, and etc. With the aims to identify an expansive soil and to know its lateral and axial strains, an experimental study was performed. Swelling tests were conducted in a specimen having diameter (d of 4,5 cm and height (h0 of 2 cm with the variations in : 1 water content wopt = 31% and 18%; 2 vertical pressure (pv 1 kPa, 3.5 kPa and 6.9 kPa; and 3 membrane thickness (t 0.7 mm and 0.5 mm. The strain in the axial direction was measured with a dial gauge that was set vertically parallel whereas the lateral strain is by measuring changes in diameter of the specimen with a digital caliper measurement tools. Based on the analysis on the identification results, the observed soil is classified as expansive soil with the expansion potential is high average. The test results show the same potential for the occurrence of lateral and lateral strain if the lateral retention (e.g. retaining wall is weak. The largest lateral and axial soil development occurred at water content w0 = 18% are 15.7% and 15.8% respectively.

  16. Axial-Gap Induction Motor For Levitated Specimens

    Science.gov (United States)

    Sridharan, Govind; Rhim, Won-Kyu; Barber, Dan; Chung, Sang

    1992-01-01

    Motor does not obscure view of specimen. Axial-gap induction motor applies torque to rotate electrostatically or electromagnetically levitated specimen of metal. Possible applications include turning specimens for uniform heating under focused laser beams and obtaining indirect measurements of resistivities or of surface tensions in molten specimens.

  17. On aspects of vibration of axially moving continua

    NARCIS (Netherlands)

    Hageraats-Ponomareva, S.

    2009-01-01

    In axially moving structures like conveyor belt systems, magnetic tapes, and so on, vibrations occur due to the presence of different kinds of imperfections in the systems. For these structures internal resonances can lead to severe vibrations. Resonance free conveyor belt systems can be constructed

  18. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... variously described as determined by the ocular biometric variables. There have been many studies on the relationship between refractive error and ocular axial length (AL), anterior chamber depth, corneal radius of curvature (CR), keratometric readings as well as other ocular biometric variables such as ...

  19. Solution of the gauge identities in the axial gauge

    International Nuclear Information System (INIS)

    Delbourgo, R.

    1981-01-01

    Starting from the spectral representation of the two-point functions in the axial gauge, the gauge identities are solved so as to express the higher-point Green functions linearly in terms of the two-point spectral function. The four-point functions are an important input for investigations of scalar electrodynamics and vector chromodynamics based on the gauge technique. (author)

  20. 3-D Simulation of Vertical-Axial Tidal Current Turbine

    Directory of Open Access Journals (Sweden)

    Zhiyang Zhang

    2016-12-01

    Full Text Available Vertical-axial tidal current turbine is the key for the energy converter, which has the advantages of simple structure, adaptability to flow and uncomplex convection device. It has become the hot point for research and application recently. At present, the study on the hydrodynamic performance of vertical-axial tidal current turbine is almost on 2-D numerical simulation, without the consideration of 3-D effect. CFD (Computational Fluid Dynamics method and blade optimal control technique are used to improve accuracy in the prediction of tidal current turbine hydrodynamic performance. Numerical simulation of vertical-axial tidal current turbine is validated. Fixed and variable deflection angle turbine are comparatively studied to analysis the influence of 3-D effect and the character of fluid field and pressure field. The method, put the plate on the end of blade, of reduce the energy loss caused by 3-D effect is proposed. The 3-D CFD numerical model of vertical-axial tidal current turbine hydrodynamic performance in this study may provide theoretical, methodical and technical reference for the optimal design of turbine.

  1. View of the Axial Field Spectrometer (R807)

    CERN Multimedia

    1980-01-01

    In this view of the Axial Field Spectrometer at I8, the vertical uranium/scintillator hadron calorimeter (just left of centre) is retracted to give access to the cylindrical central drift chamber. The yellow iron structure served as a filter to identify muons, with MWPCs and the array of Cherenkov counters to the right.

  2. Landforms along transverse faults parallel to axial zone of folded ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Earth System Science; Volume 126; Issue 1. Landforms along transverse faults parallel to axial zone of folded mountain front, north-eastern Kumaun Sub-Himalaya, India. Khayingshing ... Keywords. Himalayan Frontal Thrust; outer Kumaun Himalaya; transverse structure; folded mountain front.

  3. sizing of wind powered axial flux permanent magnet alternator using

    African Journals Online (AJOL)

    user

    2016-10-04

    Oct 4, 2016 ... Using analytical calculations, the design parameters of the alternator's main dimensions were obtained in a ... SIZING OF WIND POWERED AXIAL FLUX PERMANENT MAGNET ALTERNATOR USING ANALYTICAL APPROACH,. A. O. Otuoze, et al .... then be expressed as. Equation (7) can be re-written as.

  4. Evaluation of electromagnetic shielding effectiveness of multi-axial ...

    Indian Academy of Sciences (India)

    Abstract. The usage of electrical and electronic equipments has been increasing in daily life, which has a potential hazardous impact on humans and other living organisms. In this paper, multi-axial fabrics containing steel yarns and carbon filaments, and their polyester (PES) resin-reinforced composites have been ...

  5. Ocular Axial Length and Keratometry Readings of Normal Eyes in ...

    African Journals Online (AJOL)

    Aim: To provide average axial length and keratometry readings in healthy eyes of people in Rivers and surrounding states in southern Nigeria. This may guide the purchase of intraocular lens in the study area. Materials and methods: Four hundred consecutive patients with 800 non-cataractous eyes attending the eye clinic ...

  6. Axial drive to nonlinear flow between rotating cylinders

    Science.gov (United States)

    Ashrafi, Nariman; Hazbavi, Abbas

    2014-02-01

    Stability of pseudoplastic rotational flow between cylinders in presence of an independent axial component is investigated. The fluid is assumed to follow the Carreau model and mixed boundary conditions are imposed. The conservation of mass and momentum equations give rise to a four-dimensional low-order dynamical system, including additional nonlinear terms in the velocity components originated from the shear-dependent viscosity. In absence of the axial flow, as the pseudoplasticity effects increases, the purely-azimuthal base flow loses its stability to the vortex structure at a lower critical Taylor number. Emergence of the vortices corresponds to the onset of a supercritical bifurcation also present in the flow of a linear fluid. However, unlike the Newtonian case, pseudoplastic Taylor vortices lose their stability as the Taylor number reaches a second critical number corresponding to the onset of a Hopf bifurcation. Existence of an axial flow induced by a pressure gradient appears to further advance each critical point on the bifurcation diagram. In continuation, complete flow field together with viscosity maps is analyzed for different flow scenarios. Through evaluation of the Lyapunov exponent, flow stability and temporal behavior of the system for cases with and without axial flow are brought to attention.

  7. Employing a tri-axial accelerometer for estimating energy ...

    African Journals Online (AJOL)

    The Tritrac-R3D, a portable tri-axial accelerometer, was assessed for its ability to estimate energy expenditure during simulated load carrying activities. The Tritrac data were compared to metabolic data collected simultaneously by a MetaMax ergospirometry system while ten, healthy male subjects (aged 20.7 ±1.4 years) ...

  8. Numerical simulation of breakup and detachment of an axially ...

    Indian Academy of Sciences (India)

    Kishore Singh Patel

    Abstract. The extensional, breakup and detachment dynamics of an axially stretching Newtonian liquid bridge are investigated numerically with a dynamic domain multiphase incompressible flow solver. The mul- tiphase flow solver employs a Cahn–Hilliard phase field model to describe the evolution of the diffuse interface.

  9. Computation of the lateral and axial point spread functions in ...

    Indian Academy of Sciences (India)

    ... confocal scanning microscopes for the above-mentioned amplitude filters. These results of axial and lateral irradiances are graphically represented by constructing a computer program using MATLAB. The obtained results are compared with that obtained in case of circular, annular, and Martinez-Corral apodized aperture ...

  10. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Aim/Background: Associations between axial length (AL) to corneal radius of curvature (CR) ratio and refractive status in a healthy Nigerian adult population were studied. Materials and Methods: Healthy students and members of staff of Obafemi Awolowo Teaching Hospitals Complex, Ile-Ife, South West ...

  11. Axial heterogeneous core concept applied for super phoenix reactor

    International Nuclear Information System (INIS)

    Batista, J.L.; Renke, C.A.C.; Waintraub, M.; Santos Bastos, W. dos; Brito Aghina, L.O. de.

    1991-11-01

    Always maintaining the current design rules, this paper presents a parametric study on the type of axial heterogeneous core concept (CHA), utilizing a core of fast reactor Super Phenix type, reaching a maximum thermal burnup rate of 150000 M W d/t and being managed in single batch. (author)

  12. Fission gas retention and axial expansion of irradiated metallic fuel

    International Nuclear Information System (INIS)

    Fenske, G.R.; Emerson, J.E.; Savoie, F.E.; Johanson, E.W.

    1986-05-01

    Out-of-reactor experiments utilizing direct electrical heating and infrared heating techniques were performed on irradiated metallic fuel. The results indicate accelerated expansion can occur during thermal transients and that the accelerated expansion is driven by retained fission gases. The results also demonstrate gas retention and, hence, expansion behavior is a function of axial position within the pin

  13. Evaluation of electromagnetic shielding effectiveness of multi-axial ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... ... Lecture Workshops · Refresher Courses · Symposia. Home; Journals; Bulletin of Materials Science; Volume 39; Issue 4. Evaluation of electromagnetic shielding effectiveness of multi-axial fabrics and their reinforced PES composites. RAMAZAN ERDEM. Volume 39 Issue 4 August 2016 pp 963-970 ...

  14. Evaluation of electromagnetic shielding effectiveness of multi-axial ...

    Indian Academy of Sciences (India)

    The usage of electrical and electronic equipments has been increasing in daily life, which has a potential hazardous impact on humans and other living organisms. In this paper, multi-axial fabrics containing steel yarns and carbon filaments, and their polyester (PES) resin-reinforced composites have been prepared for ...

  15. Elevated temperature axial and torsional fatigue behavior of Haynes 188

    Science.gov (United States)

    Bonacuse, Peter J.; Kalluri, Sreeramesh

    1995-01-01

    The results are reported for high-temperature axial and torsional low-cycle fatigue experiments performed at 760 C in air on thin-walled tubular specimens of Haynes 188, a wrought cobalt-based superalloy. Data are also presented for mean coefficient of thermal expansion, elastic modulus, and shear modulus at various temperatures from room to 1000 C, and monotonic and cyclic stress-strain curves in tension and in shear at 760 C. This data set is used to evaluate several multiaxial fatigue life models (most were originally developed for room temperature multiaxial life prediction) including von Mises equivalent strain range (ASME Boiler and Pressure Code), Manson-Halford, modified multiaxiality factor (proposed in this paper), modified Smith-Watson-Topper, and Fatemi-Socie-Kurath. At von Mises equivalent strain ranges (the torsional strain range divided by the square root of 3, taking the Poisson's ratio to be 0.5), torsionally strained specimens lasted, on average, factors of 2 to 3 times longer than axially strained specimens. The modified multiaxiality factor approach shows promise as a useful method of estimating torsional fatigue life from axial fatigue data at high temperatures. Several difficulties arose with the specimen geometry and extensometry used in these experiments. Cracking at extensometer probe indentations was a problem at smaller strain ranges. Also, as the largest axial and torsional strain range fatigue tests neared completion, a small amount of specimen buckling was observed.

  16. first principles derivation of a stress function for axially symmetric

    African Journals Online (AJOL)

    HOD

    found to be identical with the Love stress function. The stress function was then applied to solve the axially symmetric problem of finding the stress fields, strain fields and displacement fields in the semi-infinite linear elastic, isotropic homogeneous medium subject to a point load P acting at the origin of coordinates also ...

  17. Kinetics and equilibria for the axial ligation of bromomethyl (aqua ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 121; Issue 6. Kinetics and equilibria for the axial ligation of bromomethyl (aqua)cobaloxime with pyridines - Isolation characterization and DNA binding. Kotha Laxma Reddy K Ashwini Kumar N Ravi Kumar Reddy Penumaka Nagababu A Panasa Reddy S ...

  18. Axial anomaly and magnetism of nuclear and quark matter

    Science.gov (United States)

    Son, D. T.; Stephanov, M. A.

    2008-01-01

    We consider the response of the QCD ground state at finite baryon density to a strong magnetic field B. We point out the dominant role played by the coupling of neutral Goldstone bosons, such as π0, to the magnetic field via the axial triangle anomaly. We show that, in vacuum, above a value of B˜mπ2/e, a metastable object appears—the π0 domain wall. Because of the axial anomaly, the wall carries a baryon number surface density proportional to B. As a result, for B≳1019G a stack of parallel π0 domain walls is energetically more favorable than nuclear matter at the same density. Similarly, at higher densities, somewhat weaker magnetic fields of order B≳1017 1018G transform the color-superconducting ground state of QCD into new phases containing stacks of axial isoscalar (η or η') domain walls. We also show that a quark-matter state known as “Goldstone current state,” in which a gradient of a Goldstone field is spontaneously generated, is ferromagnetic due to the axial anomaly. We estimate the size of the fields created by such a state in a typical neutron star to be of order 1014 1015G.

  19. Modelling the cardiac transverse-axial tubular system

    Czech Academy of Sciences Publication Activity Database

    Pásek, Michal; Šimurda, J.; Christé, G.; Orchard, C.

    2008-01-01

    Roč. 96, - (2008), s. 226-246 ISSN 0079-6107 Institutional research plan: CEZ:AV0Z20760514 Keywords : cardiac cell * transverse-axial tubular system * quantitative modelling Subject RIV: BO - Biophysics Impact factor: 6.388, year: 2008

  20. Comparison of design methods for axially loaded buckets in sand

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2015-01-01

    A study of the present knowledge about the bucket resistance for axial loading was performed considering analytical and numerical design methods as well as physical models. A case study was performed with two bucket foundations of equal diameter, but different skirt lengths installed in dense san...

  1. Axial and focal-plane diffraction catastrophe integrals

    International Nuclear Information System (INIS)

    Berry, M V; Howls, C J

    2010-01-01

    Exact expressions in terms of Bessel functions are found for some of the diffraction catastrophe integrals that decorate caustics in optics and mechanics. These are the axial and focal-plane sections of the elliptic and hyperbolic umbilic diffraction catastrophes, and symmetric elliptic and hyperbolic unfoldings of the X 9 diffraction catastrophes. These representations reveal unexpected relations between the integrals.

  2. Atlanto-axial instability in rheumatoid arthritis: a review | Omar ...

    African Journals Online (AJOL)

    Objectives: The purpose of this literature review is to identify common lesions present in the rheumatoid neck with specific emphasis to atlanto-axial instability, review its clinical presentation, imaging findings and management. Study design: A review of the English medical literature was done with focus on recent studies ...

  3. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    Aim/Background: Associations between axial length (AL) to corneal radius of curvature (CR) ratio and refractive status in a healthy Nigerian adult population were studied. Materials and Methods: Healthy students and members of staff of Obafemi Awolowo Teaching Hospitals Complex, Ile‑Ife, South West Nigeria, free of ...

  4. Ocular Axial Length Measurement Among Normal Adults Using ...

    African Journals Online (AJOL)

    2017-07-26

    Jul 26, 2017 ... Background/Introduction: Macrophthalmia and microphthalmia are cardinal signs of many orbito-ocular and systemic diseases which are seen in northern Nigeria. Some cases of refractive error may also be directly related to the ocular axial length (AL). The need for an imaging parameter that will aid their ...

  5. Axial Torsion of Gangrenous Meckel's Diverticulum Causing Small ...

    African Journals Online (AJOL)

    Meckel's diverticulum (MD) is a commonly encountered congenital anomaly of the small intestine. We report an extremely unusual case of an axially torted, gangrenous MD presenting as acute intestinal obstruction. A 26-year-old male patient presented to our emergency department with 3 days history of abdominal pain, ...

  6. Computation of the lateral and axial point spread functions in ...

    Indian Academy of Sciences (India)

    scanning microscopes for the above-mentioned amplitude filters. These results of axial and lateral irradiances are graphically represented by constructing a computer program using MATLAB. The obtained results are compared with that obtained in case of circular, annular, and Martinez-Corral apodized aperture. Keywords ...

  7. Fatigue Limit of Axially Compressed Concrete | Levchich | Nigerian ...

    African Journals Online (AJOL)

    An attempt to evaluate analytically the fatigue limit of axially loaded concrete depending upon the load parameters, number of load cycles and static short-term strength is presented. The conventional limit of concrete microcracking statical sustained strength of concrete, curvelinear relationship between fatigue limit and load ...

  8. Severe vertical atlanto-axial subluxation in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Sílvia Fernandes

    2015-01-01

    Full Text Available The authors present the imaging study of a case of severe vertical atlanto-axial subluxation in a 60-year-old male with long-term rheumatoid arthritis with severe polyarticular involvement (Class IV of Steinbrocker functional classification.

  9. Report on the Dynamical Evolution of an Axially Symmetric Quasar ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The role of the angular momentum in the regular or chaotic character of motion in an axially symmetric quasar model is examined. It is found that, for a given value of the critical angular momentum , there are two values of the mass of the nucleus for which transition from regular to chaotic motion ...

  10. Report on the Dynamical Evolution of an Axially Symmetric Quasar ...

    Indian Academy of Sciences (India)

    Abstract. The role of the angular momentum in the regular or chaotic character of motion in an axially symmetric quasar model is examined. It is found that, for a given value of the critical angular momentum Lzc, there are two values of the mass of the nucleus Mn for which transition from regular to chaotic motion occurs.

  11. Axial-flow fan with eccentric rotor | Blaho | Zede Journal

    African Journals Online (AJOL)

    Axial-flow fan with eccentric rotor. M Blaho. Abstract. No Abstract. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact AJOL · News. OTHER RESOURCES... for Researchers · for Journals ...

  12. EDITORIAL: Process Tomography

    Science.gov (United States)

    Wang, Mi

    2006-08-01

    Process tomography (PT) refers to a methodology by which the internal characteristics of process vessel reaction or pipeline flows are acquired from measurements on or outside the domain of interest in a non-invasive fashion. As a generic 'tool' PT is extremely useful in improving, for example, the modelling and design of many complex processes, in understanding the dynamic mechanisms of flowing and mixing of colloidal dispersions, and in multiphase flow phenomena, hydraulic transport and process control. Over two decades of research worldwide, PT has become a routine research tool in many research laboratories and is being accepted for process measurement and control in some industrial applications. This is the fourth special feature on process tomography after previous publications in this journal in 1996, 2001 and 2002. In this issue, recent developments in sensors, measurements and algorithms with new features for specific distinctive applications are addressed, such as the high temporal resolutions of 1000 frames/s and beyond obtained by both x-ray and impedance tomography for flow measurement and fast process reaction; interferometric tomography combining the Mach Zehnder interferometer and tomography to utilize the phase difference in propagation for visualization of particular features in a process and new three-dimensional image reconstruction algorithms in process applications. The important aspect of this issue is that it demonstrates current developments focusing on the improvement of performance at the temporal resolution, phase information and 3D algorithms for specific application. Looking back over two decades of research, we can see that the process tomography technique is maturing and its applications in industrial manufacture are being deployed as a result of the determined efforts of researchers worldwide. As Guest Editor of this special feature, I would like to thank my colleagues at the Virtual Centre for Industrial Process Tomography (VCIPT

  13. The Nucleon Axial Form Factor and Staggered Lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Aaron Scott [Chicago U.

    2017-01-01

    The study of neutrino oscillation physics is a major research goal of the worldwide particle physics program over the upcoming decade. Many new experiments are being built to study the properties of neutrinos and to answer questions about the phenomenon of neutrino oscillation. These experiments need precise theoretical cross sections in order to access fundamental neutrino properties. Neutrino oscillation experiments often use large atomic nuclei as scattering targets, which are challenging for theorists to model. Nuclear models rely on free-nucleon amplitudes as inputs. These amplitudes are constrained by scattering experiments with large nuclear targets that rely on the very same nuclear models. The work in this dissertation is the rst step of a new initiative to isolate and compute elementary amplitudes with theoretical calculations to support the neutrino oscillation experimental program. Here, the eort focuses on computing the axial form factor, which is the largest contributor of systematic error in the primary signal measurement process for neutrino oscillation studies, quasielastic scattering. Two approaches are taken. First, neutrino scattering data on a deuterium target are reanalyzed with a model-independent parametrization of the axial form factor to quantify the present uncertainty in the free-nucleon amplitudes. The uncertainties on the free-nucleon cross section are found to be underestimated by about an order of magnitude compared to the ubiquitous dipole model parametrization. The second approach uses lattice QCD to perform a rst-principles computation of the nucleon axial form factor. The Highly Improved Staggered Quark (HISQ) action is employed for both valence and sea quarks. The results presented in this dissertation are computed at physical pion mass for one lattice spacing. This work presents a computation of the axial form factor at zero momentum transfer, and forms the basis for a computation of the axial form factor momentum dependence

  14. Axial SPN and radial MOC coupled whole core transport calculation

    International Nuclear Information System (INIS)

    Cho, Jin-Young; Kim, Kang-Seog; Lee, Chung-Chan; Zee, Sung-Quun; Joo, Han-Gyu

    2007-01-01

    The Simplified P N (SP N ) method is applied to the axial solution of the two-dimensional (2-D) method of characteristics (MOC) solution based whole core transport calculation. A sub-plane scheme and the nodal expansion method (NEM) are employed for the solution of the one-dimensional (1-D) SP N equations involving a radial transverse leakage. The SP N solver replaces the axial diffusion solver of the DeCART direct whole core transport code to provide more accurate, transport theory based axial solutions. In the sub-plane scheme, the radial equivalent homogenization parameters generated by the local MOC for a thick plane are assigned to the multiple finer planes in the subsequent global three-dimensional (3-D) coarse mesh finite difference (CMFD) calculation in which the NEM is employed for the axial solution. The sub-plane scheme induces a much less nodal error while having little impact on the axial leakage representation of the radial MOC calculation. The performance of the sub-plane scheme and SP N nodal transport solver is examined by solving a set of demonstrative problems and the C5G7MOX 3-D extension benchmark problems. It is shown in the demonstrative problems that the nodal error reaching upto 1,400 pcm in a rodded case is reduced to 10 pcm by introducing 10 sub-planes per MOC plane and the transport error is reduced from about 150 pcm to 10 pcm by using SP 3 . Also it is observed, in the C5G7MOX rodded configuration B problem, that the eigenvalues and pin power errors of 180 pcm and 2.2% of the 10 sub-planes diffusion case are reduced to 40 pcm and 1.4%, respectively, for SP 3 with only about a 15% increase in the computing time. It is shown that the SP 5 case gives very similar results to the SP 3 case. (author)

  15. Mandibular condylar fractures and acute atlanto-axial subluxation Part 2 A physiopathological factor for the cervical spine sprain.

    Science.gov (United States)

    Cutilli, T; Corbacelli, A

    2009-05-01

    The aim of this study was to analyze the physiopathology of the acute cervical injure in the event of mandibular condylar fractures. As in the Part 1, 25 non-consecutive cases of condylar mandibular fractures (16 males and 9 females, mean age: 22.96/range 14-36 years) observed and treated in the Maxillofacial Surgery Department of the University of L'Aquila, have been studied. Types of fractures examined included: unilateral: 19 cases (solitary: 12; associated with other mandibular fractures: 7, homolateral: 2); bilateral: 6 cases (equivalent: 2, not equivalent: 4). A control group was constituted of 10 patients, 5 males and 5 females, aged from 19 to 24 years (mean range: 21.6) suffering from acute isolated cervical distorsion (whiplash). The study has been performed by means of the analysis of X-ray and computed tomography (CT)-CT/3D of the mandibular condylar regions, the occipital-atlanto-axial structures and the cervical region. In all the patients the following constant alterations that link up with these fractures have been observed: the rotation of atlas, the atlanto-axial subluxation and the derangement of the occipital-atlanto-epistropheal joint, homolateral to the side of the mandibular condylar fracture. The cervical spine shows the constant loss of physiological lordosis with hinge between C3 and C4. In the whiplash, as the authors have been able to assess in the control group, there are no alterations of occipital-atlanto-axial joint and the kinetic vector is placed on the longitudinal plane. In the mandibular condylar fractures the kinetic mechanism is completely different regarding the whiplash. The point of entry is the chin and the kinetic vector is oriented down-up, sometimes oblique in the opposite side. Subsequently the kinetic force is transmitted throughout the mandibular structure and causes the condylar or bicondylar fracture. The kinetic vector is placed before on the vertical plane, then on the horizontal plane and later on the vertical

  16. Non-steroidal anti-inflammatory drugs (NSAIDs) for axial spondyloarthritis (ankylosing spondylitis and non-radiographic axial spondyloarthritis)

    NARCIS (Netherlands)

    Kroon, Feline P. B.; van der Burg, Lennart R. A.; Ramiro, Sofia; Landewé, Robert B. M.; Buchbinder, Rachelle; Falzon, Louise; van der Heijde, Désirée

    2015-01-01

    Axial spondyloarthritis (axSpA) comprises ankylosing spondylitis (radiographic axSpA) and non-radiographic (nr-)axSpA and is associated with psoriasis, uveitis and inflammatory bowel disease. Non-steroidal anti-inflammatory drugs (NSAIDs) are recommended as first-line drug treatment. To determine

  17. Two-dimensional nonlinear dynamics of an axially moving viscoelastic beam with time-dependent axial speed

    International Nuclear Information System (INIS)

    Ghayesh, Mergen H.; Amabili, Marco; Farokhi, Hamed

    2013-01-01

    In the present study, the coupled nonlinear dynamics of an axially moving viscoelastic beam with time-dependent axial speed is investigated employing a numerical technique. The equations of motion for both the transverse and longitudinal motions are obtained using Newton’s second law of motion and the constitutive relations. A two-parameter rheological model of the Kelvin–Voigt energy dissipation mechanism is employed in the modelling of the viscoelastic beam material, in which the material time derivative is used in the viscoelastic constitutive relation. The Galerkin method is then applied to the coupled nonlinear equations, which are in the form of partial differential equations, resulting in a set of nonlinear ordinary differential equations (ODEs) with time-dependent coefficients due to the axial acceleration. A change of variables is then introduced to this set of ODEs to transform them into a set of first-order ordinary differential equations. A variable step-size modified Rosenbrock method is used to conduct direct time integration upon this new set of first-order nonlinear ODEs. The mean axial speed and the amplitude of the speed variations, which are taken as bifurcation parameters, are varied, resulting in the bifurcation diagrams of Poincaré maps of the system. The dynamical characteristics of the system are examined more precisely via plotting time histories, phase-plane portraits, Poincaré sections, and fast Fourier transforms (FFTs)

  18. [Producing the third dimension of flat radiographic images: analogue tomography - computer tomography].

    Science.gov (United States)

    Praestholm, J

    1995-01-01

    The inventor of computer tomography, Godfrey N. Hounsfield, mentioned in his Nobel Foundation lecture the following three main problems of conventional radiography: 1. It depicts the sum of shadows from several tissue elements at the same spot of the film. 2. The sensitivity of the employed photographic medium does not allow to differentiate between various soft tissue densities. 3. It gives no exact measure characterizing tissue densities. The first part of this article is dealing with the solution of problem number one. Researchers within medical imaging from many countries developed independently of each other a variety of methods for body-sectional imaging methods, but he did not construct any equipment. Alessandro Vallebona constructed equipment and published the first clinical body-section imaging material ever in 1930, but his method was not ideal. The first clinical material employing an ideal method was published by Bernhard Ziedses des Plantes in 1932. Methods for transverse axial tomography was independently described by William Watson in 1937, Jean Kieffer in 1938, and Shinji Takahashi in 1947. The limitation in sensitivity of the photographic medium was revealed in parallel to this development. In 1963 Allan M. Cormack described the mathematical model for absorption of ionizing rays in inhomogenous tissue. Godfrey N. Hounsfield combined this knowledge of mathematics with the fast developing computer technology and the medical need for a more sensitive registration medium. In 1971 computer tomography was a reality. One of the greatest conquests in medicine of this century had been made. Recent developments within scanner technology predict still better and safer diagnostic possibilities.

  19. Imaging of cerebellopontine angle lesions: an update. Part 2: intra-axial lesions, skull base lesions that may invade the CPA region, and non-enhancing extra-axial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Bonneville, Fabrice; Chiras, Jacques [Pitie-Salpetriere Hospital, Department of Neuroradiology, Paris (France); Savatovsky, Julien [Adolphe de Rothschild Foundation, Department of Radiology, Paris (France)

    2007-11-15

    Computed tomography (CT) and magnetic resonance (MR) imaging reliably demonstrate typical features of vestibular schwannomas or meningiomas in the vast majority of mass lesions responsible for cerebellopontine angle (CPA) syndrome. However, a large variety of unusual lesions can also be encountered in the CPA. Covering the entire spectrum of lesions potentially found in the CPA, these articles explain the pertinent neuroimaging features that radiologists need to know to make clinically relevant diagnoses in these cases, including data from diffusion- and perfusion-weighted imaging or MR spectroscopy, when available. A diagnostic algorithm based on the lesion's site of origin, shape and margins, density, signal intensity and contrast material uptake is also proposed. Non-enhancing extra-axial CPA masses are cystic (epidermoid cyst, arachnoid cyst, neurenteric cyst) or contain fat (dermoid cyst, lipoma). Tumours can also extend into the CPA by extension from the skull base (paraganglioma, chondromatous tumours, chordoma, cholesterol granuloma, endolymphatic sac tumour). Finally, brain stem or ventricular tumours can present with a significant exophytic component in the CPA that may be difficult to differentiate from an extra-axial lesion (lymphoma, hemangioblastoma, choroid plexus papilloma, ependymoma, glioma, medulloblastoma, dysembryoplastic neuroepithelial tumour). (orig.)

  20. Surgical treatment of children with non-traumatic old atlanto-axial rotatory fixation

    Directory of Open Access Journals (Sweden)

    A. V. Gubin

    2015-01-01

    Full Text Available Atlanto-axial rotatory fixation (AORF develops on the background of acute torticollis. Widely adopted terms such as C1 subluxation or atlantooccipital rotational subluxation do not reflect the core of this pathology and carry negative weight in the diagnostics and treatment of AORF. Retrospective analysis of the diagnostics and treatment outcome of 5 children with confirmed AORF diagnosis and literature review were performed. Clinical method, radiography and functional computer tomography were used to verify the diagnosis. De-rotational halo-traction and open correction with screw fixation were applied for treatment. Head position was managed to be improved in all patients. In one case the reduction was performed using correction in suboccipital segments and in other 4 cases the correction and fixation by Harms and de-rotational halo-traction allowed to correct torticollis. The pain syndrome had been arrested completely. Disease outcome resulted in formation of C1-C2 fibrous or bone fusion regardless the method of treatment. The patients with neglected AORF represent a great challenge for diagnostics and treatment. When conservative treatment fails it is necessary to involve de-rotational halo-traction with possible application of open reduction and posterior fusion. The purpose of treatment is to eliminate torticollis and pain using creation of proper C1-C2 alignment. The motions in atlantooccipital joint do not restore due to formation of the fibrous or bone fusion.

  1. Fully automatic measurements of axial vertebral rotation for assessment of spinal deformity in idiopathic scoliosis

    Science.gov (United States)

    Forsberg, Daniel; Lundström, Claes; Andersson, Mats; Vavruch, Ludvig; Tropp, Hans; Knutsson, Hans

    2013-03-01

    Reliable measurements of spinal deformities in idiopathic scoliosis are vital, since they are used for assessing the degree of scoliosis, deciding upon treatment and monitoring the progression of the disease. However, commonly used two dimensional methods (e.g. the Cobb angle) do not fully capture the three dimensional deformity at hand in scoliosis, of which axial vertebral rotation (AVR) is considered to be of great importance. There are manual methods for measuring the AVR, but they are often time-consuming and related with a high intra- and inter-observer variability. In this paper, we present a fully automatic method for estimating the AVR in images from computed tomography. The proposed method is evaluated on four scoliotic patients with 17 vertebrae each and compared with manual measurements performed by three observers using the standard method by Aaro-Dahlborn. The comparison shows that the difference in measured AVR between automatic and manual measurements are on the same level as the inter-observer difference. This is further supported by a high intraclass correlation coefficient (0.971-0.979), obtained when comparing the automatic measurements with the manual measurements of each observer. Hence, the provided results and the computational performance, only requiring approximately 10 to 15 s for processing an entire volume, demonstrate the potential clinical value of the proposed method.

  2. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  3. Mathematical Methods in Tomography

    CERN Document Server

    Louis, Alfred; Natterer, Frank

    1991-01-01

    The conference was devoted to the discussion of present and future techniques in medical imaging, including 3D x-ray CT, ultrasound and diffraction tomography, and biomagnetic ima- ging. The mathematical models, their theoretical aspects and the development of algorithms were treated. The proceedings contains surveys on reconstruction in inverse obstacle scat- tering, inversion in 3D, and constrained least squares pro- blems.Research papers include besides the mentioned imaging techniques presentations on image reconstruction in Hilbert spaces, singular value decompositions, 3D cone beam recon- struction, diffuse tomography, regularization of ill-posed problems, evaluation reconstruction algorithms and applica- tions in non-medical fields. Contents: Theoretical Aspects: J.Boman: Helgason' s support theorem for Radon transforms-a newproof and a generalization -P.Maass: Singular value de- compositions for Radon transforms- W.R.Madych: Image recon- struction in Hilbert space -R.G.Mukhometov: A problem of in- teg...

  4. Controllable tomography phase microscopy

    Science.gov (United States)

    Xiu, Peng; Zhou, Xin; Kuang, Cuifang; Xu, Yingke; Liu, Xu

    2015-03-01

    Tomography phase microscopy (TPM) is a new microscopic method that can quantitatively yield the volumetric 3D distribution of a sample's refractive index (RI), which is significant for cell biology research. In this paper, a controllable TPM system is introduced. In this system a circulatory phase-shifting method and piezoelectric ceramic are used which enable the TPM system to record the 3D RI distribution at a more controllable speed, from 1 to 40 fps, than in the other TPM systems reported. The resolution of the RI distribution obtained by this controllable TPM is much better than that in images recorded by phase contrast microscopy and interference tomography microscopy. The realization of controllable TPM not only allows for the application of TPM to the measurement of kinds of RI sample, but also contributes to academic and technological support for the practical use of TPM.

  5. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  6. Reinforced concrete tomography

    International Nuclear Information System (INIS)

    Mariscotti, M.A.J.; Morixe, M.; Tarela, P.A.; Thieberger, P.

    1997-01-01

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of ± 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) [es

  7. Non-steroidal anti-inflammatory drugs (NSAIDs) for axial spondyloarthritis (ankylosing spondylitis and non-radiographic axial spondyloarthritis).

    Science.gov (United States)

    Kroon, Féline P B; van der Burg, Lennart R A; Ramiro, Sofia; Landewé, Robert B M; Buchbinder, Rachelle; Falzon, Louise; van der Heijde, Désirée

    2015-07-17

    Axial spondyloarthritis (axSpA) comprises ankylosing spondylitis (radiographic axSpA) and non-radiographic (nr-)axSpA and is associated with psoriasis, uveitis and inflammatory bowel disease. Non-steroidal anti-inflammatory drugs (NSAIDs) are recommended as first-line drug treatment. To determine the benefits and harms of NSAIDs in axSpA. We searched CENTRAL, MEDLINE and EMBASE to 18 June 2014. Randomised controlled trials (RCTs) or quasi-RCTs of NSAIDs versus placebo or any comparator in adults with axSpA and observational cohort studies studying the long term effect (≥ six months) of NSAIDs on radiographic progression or adverse events (AEs). The main comparions were traditional or COX-2 NSAIDs versus placebo. The major outcomes were pain, Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Bath Ankylosing Spondylitis Functional Index (BASFI), Bath Ankylosing Spondylitis Metrology Index (BASMI), radiographic progression, number of withdrawals due to AEs and number of serious AEs Two review authors independently selected trials for inclusion, assessed the risk of bias, extracted data and assessed the quality of evidence for major outcomes using GRADE. We included 39 studies (35 RCTs, two quasi-RCTs and two cohort studies); and 29 RCTs and two quasi-RCTs (n = 4356) in quantitative analyses for the comparisons: traditional NSAIDs versus placebo, cyclo-oxygenase-2 (COX-2) versus placebo, COX-2 versus traditional NSAIDs, NSAIDs versus NSAIDs, naproxen versus other NSAIDs, low versus high dose. Most trials were at unclear risk of selection bias (n = 29), although blinding of participants and personnel was adequate in 24 trials. Twenty-five trials had low risk of attrition bias and 29 trials had low risk of reporting bias. Risk of bias in both cohort studies was high for study participation, and low or unclear for all other criteria. No trials in the meta-analyses assessed patients with nr-axSpA.Traditional NSAIDs were more beneficial than placebo at six

  8. Simultaneous measurement of cerebral blood flow and oxygen extraction fraction by positron emission tomography: theoretical study and experimental evidence of cerebral blood flow measurement with the C15O2 continuous inhalation technique

    International Nuclear Information System (INIS)

    Steinling, M.

    1983-01-01

    The method of the continuous inhalation technique of oxygen-15 labelled CO 2 coupled with positron emission tomography for the measurement of cerebral blood flow (C.B.F.) is described. An indirect experimental verification that this technique allowed the measurement of C.B.F. has been carried out in baboons by showing the expected change in the measured parameter with variations in the PaCO 2 . A critical investigation of the C 15 O 2 model was performed. The amount of tracer present in the cerebral vascular pool has a negligible effect on C.B.F. value. The use of a mean brain-blood partition coefficient of water instead of that specific to gray or to white matter is commented upon, and its influence on the final C.B.F. value is studied. Lastly, the problem of the limited diffusion of water across the blood-brain-barrier is discussed. The study of the combined effects of gray-white mixing and limited wates extraction of the C.B.F. value shows that the C 15 O 2 technique tends to understimate real C.B.F., and that this error is more severe with high flows and even gray white mixing. These limitations do not depart from the possibility to estimate in the same brain locus not only C.B.F. but oxygen utilization as well by the consecutive inhalation of C 15 O 2 and 15 O 2 . The advantages of this possibility has already been shown in a number of clinical studies [fr

  9. Polychromatic diffraction contrast tomography

    International Nuclear Information System (INIS)

    King, A.; Reischig, P.; Adrien, J.; Peetermans, S.; Ludwig, W.

    2014-01-01

    This tutorial review introduces the use of polychromatic radiation for 3D grain mapping using X-ray diffraction contrast tomography. The objective is to produce a 3D map of the grain shapes and orientations within a bulk, millimeter-sized polycrystalline sample. The use of polychromatic radiation enables the standard synchrotron X-ray technique to be applied in a wider range of contexts: 1) Using laboratory X-ray sources allows a much wider application of the diffraction contrast tomography technique. 2) Neutron sources allow large samples, or samples containing high Z elements to be studied. 3) Applied to synchrotron sources, smaller samples may be treated, or faster measurements may be possible. Challenges and particularities in the data acquisition and processing, and the limitations of the different variants, are discussed. - Highlights: • We present a tutorial review of polychromatic diffraction contrast tomography techniques. • The use of polychromatic radiation allows the standard synchrotron DCT technique to be extended to a range of other sources. • The characteristics and limitations of all variants of the techniques are derived, discussed and compared. • Examples using laboratory X-ray and cold neutron radiation are presented. • Suggestions for the future development of these techniques are presented

  10. Coded aperture tomography revisited

    International Nuclear Information System (INIS)

    Bizais, Y.; Rowe, R.W.; Zubal, I.G.; Bennett, G.W.; Brill, A.B.

    1983-01-01

    Coded aperture (CA) Tomography never achieved wide spread use in Nuclear Medicine, except for the degenerate case of Seven Pinhole tomagraphy (7PHT). However it enjoys several attractive features (high sensitivity and tomographic ability with a statis detector). On the other hand, resolution is usually poor especially along the depth axis and the reconstructed volume is rather limited. Arguments are presented justifying the position that CA tomography can be useful for imaging time-varying 3D structures, if its major drawbacks (poor longitudinal resolution and difficulty in quantification) are overcome. Poor results obtained with 7PHT can be explained by both a very limited angular range sampled and a crude modelling of the image formation process. Therefore improvements can be expected by the use of a dual-detector system, along with a better understanding of its sampling properties and the use of more powerful reconstruction algorithms. Non overlapping multipinhole plates, because they do not involve a decoding procedure, should be considered first for practical applications. Use of real CA should be considered for cases in which non overlapping multipinhole plates do not lead to satisfactory solutions. We have been and currently are carrying out theoretical and experimental works, in order to define the factors which limit CA imaging and to propose satisfactory solutions for Dynamic Emission Tomography

  11. On the performance of circular concrete-filled high strength steel columns under axial loading

    Directory of Open Access Journals (Sweden)

    Mohamed Mahmoud El-Heweity

    2012-06-01

    Full Text Available This work presents a numerical study to investigate the performance of circular high-strength steel tubes filled with concrete (CFT under monotonic axial loading. A model is developed to implement the material constitutive relationships and non-linearity. Calibration against previous experimental data shows good agreement. A parametric study is then conducted using the model and compared with codes provisions. Strength and ductility of confined concrete are of primary concern. Variables considered are yield stress of steel tube and column diameter. The assessment of column performance is based on axial load carrying capacities and enhancements of both strength and ductility due to confinement. Two parameters namely strength enhancement factor (Kf and ductility index (μ are clearly defined and introduced for assessment. Results indicate that both concrete strength and ductility of CFT columns are enhanced but to different extents. The ductile behaviors are significantly evident. The increase in yield stress of steel tube has a minimal effect on concrete strength but pronounced effect on concrete ductility. However, reduction in ductility is associated with using high-tensile steel of Grade 70. The overall findings indicate that the use of high-strength tube in CFT columns is not promising. This finding may seriously be considered in seismic design.

  12. Unilateral atlanto-axial fractures in near side impact collisions: An under recognized entity in cervical trauma

    Directory of Open Access Journals (Sweden)

    Andrew M Lozen

    2014-01-01

    Full Text Available Objective: Nearside impact collisions presenting with lateral mass fractures of atlanto-axial vertebrae contralateral to the impact site represents a rare fracture pattern that does not correlate with previously described injury mechanism. We describe our clinical experience with such fractures and propose a novel description of biomechanical forces involved in this unique injury pattern. The findings serve to alert clinicians to potentially serious consequences of associated unrecognized and untreated vertebral artery injury. Material and Methods : In addition to describing our clinical experience with three of these fractures, a review of Crash Injury Research and Engineering Network (CIREN database was conducted to further characterize such fractures. A descriptive analysis of three recent lateral mass fractures of the atlanto-axial segment is coupled with a review of the CIREN database. A total of 4047 collisions were screened for unilateral fractures of atlas or axis. Information was screened for side of impact and data regarding impact velocity, occupant injuries and use of restraints. Results: Following screening of unilateral fractures of atlas and axis for direct side impacts, 41 fractures were identified. Cross referencing these cases for occurrence contralateral to side of impact identified four such fractures. Including our recent clinical experience, seven injuries were identified: Five C1 and two C2 fractures. Velocity ranged from 14 to 43 km/h. Two associated vertebral artery injuries were identified. Conclusions: Complexity of the atlanto-axial complex is responsible for a sequence of events that define load application in side impacts. This study demonstrates the vulnerability of vertebral artery to injury under unique translational forces and supports the use or routine screening for vascular injury. Diminished sensitivity of plain radiography in identifying these injuries suggests that computerized tomography should be used in

  13. Geometry of the articular facets of the lateral atlanto-axial joints in the case of occipitalization.

    Science.gov (United States)

    Ryniewicz, A M; Skrzat, J; Ryniewicz, A; Ryniewicz, W; Walocha, J

    2010-08-01

    This study investigates if atlanto-occipital fusion affects the size and geometrical configuration of the articular facets of the atlanto-axial joint. Morphometric analysis was performed on the male adult skull, the occipital bone of which is assimilated with the first cervical vertebrae (the atlas). The perimeter, Feret's diameter, surface area, and circularity of the inferior articular fa-cets were measured. However, we did not observe significant bilateral differences in size of the inferior articular facets of the assimilated atlas compared to normal first cervical vertebrae. Geometrical conformation of the articular facets of the atlas and axis was assessed using a coordinate measuring machine (PMM - 12106, Leitz). The results obtained from this machine indicated that the inferior articular facets of the assimilated atlas presented asymmetrical orientation compared to the normal anatomy of the atlas. Hence, in the case of occipitalization, the gap between the articulating facets of the atlas and the axis was measured to be greater than in the normal atlanto-axial joint. Computer assisted tomography was applied to visualise the anatomical relationship between the inferior articular facets of the assimilated atlas and the corresponding facets located on the axis. In this case, radiographic examination revealed that the bilaterally articulating facets (inferior and superior) showed disproportion in their adjustment within the lateral atlanto-axial joints. Thus, we concluded that the fusion of the atlas with the occipital bone altered the geometry of the inferior articular facets of the atlas and influenced the orientation of the superior articular facets of the axis.

  14. Early brain enlargement and elevated extra-axial fluid in infants who develop autism spectrum disorder.

    Science.gov (United States)

    Shen, Mark D; Nordahl, Christine W; Young, Gregory S; Wootton-Gorges, Sandra L; Lee, Aaron; Liston, Sarah E; Harrington, Kayla R; Ozonoff, Sally; Amaral, David G

    2013-09-01

    resonance imaging study to prospectively evaluate brain growth trajectories from infancy in children who develop autism spectrum disorder. The presence of excessive extra-axial fluid detected as early as 6 months and the lack of resolution by 24 months is a hitherto unreported brain anomaly in infants who later develop autism spectrum disorder. This is also the first magnetic resonance imaging evidence of brain enlargement in autism before age 2. These findings raise the potential for the use of structural magnetic resonance imaging to aid in the early detection of children at risk for autism spectrum disorder or other neurodevelopmental disorders.

  15. Mixing and axial dispersion in Taylor-Couette flow: experimental and numerical study

    International Nuclear Information System (INIS)

    Nemri, M.

    2013-01-01

    Taylor-Couette flows between two concentric cylinders have great potential applications in chemical engineering. They are particularly convenient for two-phase small scale devices enabling solvent extraction operations. An experimental device was designed with this idea in mind. It consists of two concentric cylinders with the inner one rotating and the outer one fixed. Taylor-Couette flows take place in the annular gap between them, and are known to evolve towards turbulence through a sequence of successive instabilities. Macroscopic quantities, such as axial dispersion and mixing index, are extremely sensitive to these flow structures, which may lead to flawed modelling of the coupling between hydrodynamics and mass transfer. This particular point has been studied both experimentally and numerically. The flow and mixing have been characterized by means of flow visualization and simultaneous PIV (Particle Imaging Velocimetry) and PLIF (Planar Laser Induced Fluorescence) measurements. PLIF visualizations showed clear evidences of different transport mechanisms including 'intra-vortex mixing' and 'inter-vortex mixing'. Under WVF and MWVF regimes, intra-vortex mixing is controlled by chaotic advection, due to the 3D nature of the flow, while inter-vortex transport occurs due to the presence of waves between neighboring vortices. The combination of these two mechanisms results in enhanced axial dispersion. We showed that hysteresis may occur between consecutive regimes depending on flow history and this may have a significant effect on mixing for a given Reynolds number. The axial dispersion coefficient Dx evolution along the successive flow states was investigated thanks to dye Residence Time Distribution measurements (RTD) and particle tracking (DNS). Both experimental and numerical results have confirmed the significant effect of the flow structure and history on axial dispersion. Our study confirmed that the commonly used 1-parameter chemical engineering models (e

  16. Axial segregation in spherical and cylindrical rotating tumblers

    Directory of Open Access Journals (Sweden)

    D’Ortona Umberto

    2017-01-01

    Full Text Available Monodisperse and bidisperse granular flows are studied in rotating tumblers using DEM. In spherical tumblers, flowing particles’ trajectories do not follow straight lines but are curved. At the same time particles near the surface drift toward the pole, inducing two global recirculation cells. Combined with radial segregation, drift and curvature compete to impose the axial segregation pattern: Small-Large-Small (SLS or Large-Small-Large (LSL. Fill level, rotation speed and wall roughness influence drift and curvature, and modify the resulting segregation pattern. In cylindrical tumblers, equivalent recirculation cells occur next to the end walls. A second pair of recirculation cells with a weak drift in the opposite direction appears at the center for long enough tumblers. Unlike the sphere case, curvature and drift in the primary cells combine to push large particles toward the end walls, explaining why large particle bands appear at the end walls for axial segregation in cylinder.

  17. Classical theory of the Kumakhov radiation in axial channeling

    International Nuclear Information System (INIS)

    Khokonov, M.K.; Komarov, F.F.; Telegin, V.I.

    1984-01-01

    The paper considers radiation of ultrarelativistic electrons in axial channeling initially predicted by Kumakhov. The consideration is based on the results of solution of the Fokker-Planck equation. The spectral-angular characteristics of the Kumakhov radiation in thick single crystals are calculated. It is shown that in heavy single crystals the energy losses on radiation can amount to a considerable portion of the initial beam energy. The possibility of a sharp increase of radiation due to a decrease of crystal temperature is discussed. It is shown that radiation intensity in axial channeling is weakly dependent on the initial angle of the electron entrance into the channel if this angle changes within the limits of a critical one. (author)

  18. Impaired bed mobility: quantitative torque analysis with axial inertial sensors.

    Science.gov (United States)

    Bhidayasiri, Roongroj; Sringean, Jirada; Thanawattano, Chusak

    2017-08-01

    Difficulty in turning in bed is rated as the most troublesome night-time symptom among Parkinson's disease (PD) patients. To develop a practical objective method for home assessment of a patient's ability to turn in bed. Nocturnal parameters and torque of self-turning in bed from 17 PD couples were assessed and compared using a wearable axial sensor for two nights in their homes. The torque of axial rotation which indicates the ability of PD patients to turn in bed was significantly less than their spouses (p turning in bed and total unified Parkinson's Disease Rating Scale score (r = 0.71; p = 0.001), and total Nocturnal Akinesia Dystonia and Cramp score (r = 0.634; p = 0.006). Our study confirms a decreased ability in turning in PD.

  19. Vector and axial nucleon form factors: A duality constrained parameterization

    International Nuclear Information System (INIS)

    Bodek, A.; Avvakumov, S.; Bradford, R.; Budd, H.

    2008-01-01

    We present new parameterizations of vector and axial nucleon form factors. We maintain an excellent descriptions of the form factors at low momentum transfers, where the spatial structure of the nucleon is important, and use the Nachtman scaling variable ξ to relate elastic and inelastic form factors and impose quark-hadron duality constraints at high momentum transfers where the quark structure dominates. We use the new vector form factors to re-extract updated values of the axial form factor from neutrino experiments on deuterium. We obtain an updated world average value from ν μ d and pion electroproduction experiments of M A =1.014±0.014 GeV/c 2 . Our parameterizations are useful in modeling neutrino interactions at low energies (e.g. for neutrino oscillations experiments). The predictions for high momentum transfers can be tested in the next generation electron and neutrino scattering experiments. (orig.)

  20. Organocatalyzed Asymmetric Synthesis of Axially, Planar, and Helical Chiral Compounds.

    Science.gov (United States)

    Shirakawa, Seiji; Liu, Shiyao; Kaneko, Shiho

    2016-02-04

    Axially, planar, and helical chiral compounds are indispensable building blocks in modern organic synthesis. A wide variety of chiral ligands and catalysts were designed based on these chiral scaffolds, and these chiral ligands and catalysts were used for various catalytic asymmetric transformations to produce important chiral compounds in an optically enriched form. Furthermore, these chiral skeletons are found in the structure of biologically active natural products. Thus, the development of efficient enantioselective methods for the synthesis of these chiral compounds is an important task in the field of organic chemistry. In the last few years, organocatalyzed approaches, which are one of the most reliable catalytic asymmetric methods, became a hot topic. This Focus Review summarizes asymmetric organocatalytic methods for the synthesis of axially, planar, and helical chiral compounds as useful chiral building blocks. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. An Axial Sliding Test for machine elements surfaces

    DEFF Research Database (Denmark)

    Godi, Alessandro; Grønbæk, J.; Mohaghegh, Kamran

    2012-01-01

    are necessary: a press to provide the normal pressure and a tensile machine to perform the axial movements. The test is calibrated so that the correspondence between the normal pressure and the container advancement is found. Finally, preliminary tests are carried out involving a multifunctional and a fine......Throughout the years, it has become more and more important to find new methods for reducing friction and wear occurrence in machine elements. A possible solution is found in texturing the surfaces under tribological contact, hence the development and spread of plateau-honed surface for cylinder...... liners. To prove the efficacy of a particular textured surface, it is paramount to perform experimental tests under controlled laboratory conditions. In this paper a new test rig simulating pure sliding conditions is presented, dubbed Axial Sliding Test. It presents four major components: a rod, a sleeve...

  2. Buckling Imperfection Sensitivity of Axially Compressed Orthotropic Cylinders

    Science.gov (United States)

    Schultz, Marc R.; Nemeth, Michael P.

    2010-01-01

    Structural stability is a major consideration in the design of lightweight shell structures. However, the theoretical predictions of geometrically perfect structures often considerably over predict the buckling loads of inherently imperfect real structures. It is reasonably well understood how the shell geometry affects the imperfection sensitivity of axially compressed cylindrical shells; however, the effects of shell anisotropy on the imperfection sensitivity is less well understood. In the present paper, the development of an analytical model for assessing the imperfection sensitivity of axially compressed orthotropic cylinders is discussed. Results from the analytical model for four shell designs are compared with those from a general-purpose finite-element code, and good qualitative agreement is found. Reasons for discrepancies are discussed, and potential design implications of this line of research are discussed.

  3. Involvement of the axial skeleton in psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    E. E. Gubar

    2017-01-01

    Full Text Available The involvement of the spine in psoriatic arthritis (PsA is observed in a large number of cases; however, a unified approach to solving this problem has not yet been formed. Criteria for the diagnosis of psoriatic spondylitis have not been clearly defined; internationally accepted definitions for this concept are absent; criteria for a PsA exacerbation and remission have not been formulated with regard to spondylitis. The specialists of GRAPPA (Group for Research and Assessment of Psoriasis and Psoriatic Arthritis have no their own recommendations for the treatment of axial involvement in PsA now. The therapeutic tactics used in the treatment of axial spondylitis and ankylosing spondylitis is borrowed in this area. The involvement of the spine calls for further investigation.

  4. Axial Ge/Si nanowire heterostructure tunnel FETs

    Energy Technology Data Exchange (ETDEWEB)

    Picraux, Sanuel T [Los Alamos National Laboratory; Daych, Shadi A [Los Alamos National Laboratory

    2010-01-01

    The vapor-liquid-solid (VLS) growth of semiconductor nanowires allows doping and composition modulation along their axis and the realization of axial 1 D heterostructures. This provides additional flexibility in energy band-edge engineering along the transport direction which is difficult to attain by planar materials growth and processing techniques. We report here on the design, growth, fabrication, and characterization of asymmetric heterostructure tunnel field-effect transistors (HTFETs) based on 100% compositionally modulated Si/Ge axial NWs for high on-current operation and low ambipolar transport behavior. We discuss the optimization of band-offsets and Schottky barrier heights for high performance HTFETs and issues surrounding their experimental realization. Our HTFET devices with 10 nm PECVD SiN{sub x} gate dielectric resulted in a measured current drive exceeding 100 {mu}A/{mu}m (I/{pi}D) and 10{sup 5} I{sub on}/I{sub off} ratios.

  5. Buckling localization in a cylindrical panel under axial compression

    DEFF Research Database (Denmark)

    Tvergaard, Viggo; Needleman, A.

    2000-01-01

    Localization of an initially periodic buckling pattern is investigated for an axially compressed elastic-plastic cylindrical panel of the type occurring between axial stiffeners on cylindrical shells. The phenomenon of buckling localization and its analogy with plastic flow localization in tensile...... test specimens is discussed in general. For the cylindrical panel, it is shown that buckling localization develops shortly after a maximum load has been attained, and this occurs for a purely elastic panel as well as for elastic-plastic panels. In a case where localization occurs after a load maximum......, but where subsequently the load starts to increase again, it is found that near the local load minimum, the buckling pattern switches back to a periodic type of pattern. The inelastic material behavior of the panel is described in terms of J(2) corner theory, which avoids the sometimes unrealistically high...

  6. Accuracy Improvement of Axial Power Shape Reconstruction Using GMDH Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Yum, Seongpil; Kim, Jaemin; Park, Minyong; Choe, Jiwon; Zhang, Peng; Lee, Deokjung [UNIST, Ulsan (Korea, Republic of); Shin, Ho Cheol [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    This paper applies Group Method of Data Handling (GMDH) algorithm to improve the reconstruction accuracy. Reference three-dimensional power distributions are generated for Shinkori Unit 1 Cycle 3 by simulating Xe transients in BOC, MOC, and EOC, which include saddle, top- and bottom-skewed shapes. Using these power distributions, the axial power distributions were reconstructed by GMDH and the 5th order Fourier series method. It was shown that GMDH algorithm reduced the average Root-Mean-Square-Error (RMSE) from 1.01% of Fourier series method, down to 0.17%. This paper presents the accuracy improvement of axial power reconstruction using GMDH algorithm with the first order polynomial basis function compared to the COLSS Fourier series expansion algorithm.

  7. Axial weak currents in the Wess-Zumino term

    International Nuclear Information System (INIS)

    Fujikawa, Kazuo

    1986-01-01

    In a simplified model lagrangian of 3 quarks with an SU(2)sub(L) gauging of chiral SU(3)sub(L)xSU(3)sub(R) to introduce W-boson, we analyse certain complications associated with the low-energy theorem including axial weak fields. We first show that the low-energy amplitude is independent of the form of the quark-level anomalous identity, whether in the covariant form or the consistent form. However, the interplay of the short-distance dynamics (anomalous identity) and the long-distance dynamics (low-energy theorem) becomes involved in the presence of axial fields. We then discuss what kinds of conditions single out the gauged Wess-Zumino term as a low-energy effective action. The connection of the low-energy theorem with the 't Hooft anomaly matching condition is also discussed. (orig.)

  8. [Dome-shaped macula: appearance on ultrasound and optical coherence tomography].

    Science.gov (United States)

    Chéour, M; Ben Aleya, N; Brour, J; Falfoul, Y; Agrebi, S; Skhiri, M; Kraïem, A

    2013-10-01

    The purpose of our work is to demonstrate the role of optical coherence tomography and ocular ultrasound in the diagnosis of the dome-shaped macula in high myopia. We report the case of a patient with high myopia who presented with a decrease in visual acuity and metamorphopsia in the left eye. She underwent visual acuity measurement, biomicroscopic examination and measurement of axial length. B-mode ultrasound and optical coherence tomography showed a projection of the macula in the convexity of the myopic staphyloma confirming the diagnosis of dome-shaped macula. Dome-shaped macula is a recently discovered entity, which may be responsible for a decrease in visual acuity in patients with high myopic posterior staphyloma. Ultrasound and optical coherence tomography are very helpful in making the diagnosis. Copyright © 2013. Published by Elsevier Masson SAS.

  9. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  10. Dynamics of tubular cylindrical structures in axial flow.

    OpenAIRE

    Paidoussis, Michael P.

    2017-01-01

    The dynamics of slender cylinders in axial flow subject to conventional boundary conditions is recalled first. This is followed by brief reviews and discussion of new developments in (i) the dynamics of unconventionally supported cylinders, e.g. cylinders free at the upstream end and supported at the downstream one, (ii) the dynamics of cylinders subject to both internal and external flow for applications in oil and gas drilling and production, as well as hydrocarbon storage in salt-mined cav...

  11. Experimental investigations on an axial grooved cryogenic heat pipe

    Directory of Open Access Journals (Sweden)

    Senthil Kumar Muniappan

    2012-01-01

    Full Text Available This paper deals with development and studies of a trapezoidal axial grooved nitrogen heat pipe. A special liquid nitrogen cryostat has been designed and developed for evaluating the performance of heat pipe where the condenser portion is connected to the cold sink externally. Experiments have been performed on the heat pipe as well as on an equivalent diameter copper rod at different heat loads. The steady state performance of the heat pipe is compared with that of copper rod.

  12. Axially symmetric domain wall in 2+1-dimensions

    International Nuclear Information System (INIS)

    Soda, Jiro; Yamanaka, Yuki.

    1991-04-01

    An axially symmetric domain wall (string) in 2+1-dimensions is investigated in the synchronous gauge. This problem is also regarded as a cylindrical symmetric domain wall (membrane) in 3+1-dimensions. Using Israel's method, we present a general solution. As a special case, a static solution is obtained which agrees with the previous result of Deser and Jackiw obtained by another method. (author)

  13. Axially symmetric, stationary gravitational field equations and pseudospherical surfaces

    International Nuclear Information System (INIS)

    Tomimatsu, Akira.

    1981-04-01

    For axially symmetric, stationary gravitational field equations, a new Lax pair of the inverse scattering method is presented from a geometrical point of view. The metric coefficient e sup(2γ) (= -g sub(rho rho)g sub(tt)sup(-1)) is taken as the basic field variable, which satisfies an equation describing pseudospherical surfaces, i.e., surfaces of constant negative Gaussian curvature. The equations for other metric coefficients are also discussed. (author)

  14. Overview of the Axial Field Spectrometer in the ISR tunnel

    CERN Multimedia

    1980-01-01

    A view of the Axial Field Spectrometer – the last large experiment at the ISR. The horizontal top and vertical outer arrays of the uranium-scintillator hadron calorimeter are clear to be seen, with the blue cylindrical pole piece of the magnet just visible. The pipes that are visible in front of the pole piece are cryogenic feed pipes for the superconducting low-beta quadrupoles.

  15. Channel of Axial Injection of DC-60 Cyclotron

    CERN Document Server

    Gikal, B N; Bogomolov, S L; Borisenko, A N; Borisov, O N; Gulbekyan, G G; Ivanenko, I A; Kalagin, I V; Kazacha, V I; Kazarinov, N Yu; Khabarov, M V; Lysukhin, S N; Melnikov, V N; Paschenko, S V; Tikhomirov, A V

    2006-01-01

    The design study and realization of the axial injection beam line of DC-60 cyclotron constructed at the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research are given. The channel allows one to transport and to inject into the cyclotron ions with mass-to-charge ratio $A/Z$ being within interval A/Z=6-12 and kinetic energy up to 17 $Z/A$ keV/m.u.

  16. Colonic surveillance by CT colonography using axial images only

    International Nuclear Information System (INIS)

    Bruzzi, John F.; Brennan, Darren D.; Fenlon, Helen M.; Moss, Alan C.; MacMathuna, Padraic

    2004-01-01

    Patients at increased risk of colon cancer require strict colon surveillance. Our objective was to establish the efficacy of 2D axial CT colonography as a surveillance test when performed in routine clinical practice. Eighty-two patients at increased risk of colon cancer underwent CT colonography followed by conventional colonoscopy on the same morning. CT colonography studies were performed on a four-ring multidetector CT scanner (100 mAs, 120 kVp, 4 x 2.5 collimation) and were interpreted by two radiologists using 2D axial images only. Results were correlated with findings at colonoscopy. Note was made of subsequent histology reports from polypectomy specimens. A total of 52 polyps were detected at colonoscopy. Using 2D axial images alone, with no recourse to 2D multiplanar or 3D views, the sensitivity of CT colonography was 100, 33 and 19% for polyps larger than 9, 6-9 and smaller than 6 mm, respectively. Per-patient specificities were 98.8, 96 and 81.5%, respectively. Twenty-nine percent of polyps smaller than 1 cm were adenomatous and there were no histological features of severe dysplasia. CT colonography is a useful colon surveillance tool for patients at increased risk of colon cancer. It has a high specificity for identifying patients who should proceed to colonoscopy and polypectomy, while allowing further colon examination to be deferred in patients with normal studies. Using 2D axial images only, CT colonography can be performed as part of the daily CT workload, with a very low rate of referral for unnecessary colonoscopy. (orig.)

  17. Numerical analysis of a microwave torch with axial gas injection

    Energy Technology Data Exchange (ETDEWEB)

    Gritsinin, S. I.; Davydov, A. M.; Kossyi, I. A., E-mail: kossyi@fpl.gpi.ru [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation); Kulumbaev, E. B. [National Research University Belgorod State University (Russian Federation); Lelevkin, V. M. [Kyrgyz-Russian Slavic University (Kyrgyzstan)

    2013-07-15

    The characteristics of a microwave discharge in an argon jet injected axially into a coaxial channel with a shortened inner electrode are numerically analyzed using a self-consistent equilibrium gas-dynamic model. The specific features of the excitation and maintenance of the microwave discharge are determined, and the dependences of the discharge characteristics on the supplied electromagnetic power and gas flow rate are obtained. The calculated results are compared with experimental data.

  18. One-loop corrections to the baryon axial vector current

    Indian Academy of Sciences (India)

    2012-10-06

    Oct 6, 2012 ... 917–920. One-loop corrections to the baryon axial vector current. M A HERNÁNDEZ-RUÍZ1,2. 1Instituto de Física, Universidad Autónoma de San Luis Potosí,. Av. Manuel Nava 6 Zona Universitaria 78290, San Luis Potosí SLP, México. 2Facultad de Ciencias Químicas, Universidad Autónoma de Zacatecas,.

  19. Taming axial dispersion in hydrodynamic chromatography columns through wall patterning

    Science.gov (United States)

    Adrover, Alessandra; Cerbelli, Stefano; Giona, Massimiliano

    2018-04-01

    A well-known limitation of hydrodynamic chromatography arises from the synergistic interaction between transverse diffusion and streamwise convection, which enhances axial dispersion through the Taylor-Aris mechanism. We show that a periodic sequence of slip/no-slip conditions at the channel walls (e.g., representing wall indentations hosting stable air pockets) can significantly reduce axial dispersion, thus enhancing separation performance. The theoretical/numerical analysis is based on a generalization of Brenner's macrotransport approach to solute transport, here modified to account for the finite-size of the suspended particles. The most effective dispersion-taming outcome is observed when the alternating sequence of slip/no-slip conditions yields non-vanishing cross-sectional flow components. The combination of these components with the hindering interaction between the channel boundaries and the finite-sized particles gives rise to a non-trivial solution of Brenner's problem on the unit periodic cell, where the cross-sectional particle number density departs from the spatially homogeneous condition. In turn, this effect impacts upon the solution of the so-called b-field defining the large-scale dispersion tensor, with an overall decremental effect on the axial dispersion coefficient and on the Height Equivalent of a Theoretical Plate.

  20. Fundamental metallurgical aspects of axial splitting in zircaloy cladding

    International Nuclear Information System (INIS)

    Chung, H. M.

    2000-01-01

    Fundamental metallurgical aspects of axial splitting in irradiated Zircaloy cladding have been investigated by microstructural characterization and analytical modeling, with emphasis on application of the results to understand high-burnup fuel failure under RIA situations. Optical microscopy, SEM, and TEM were conducted on BWR and PWR fuel cladding tubes that were irradiated to fluence levels of 3.3 x 10 21 n cm -2 to 5.9 x 10 21 n cm -2 (E > 1 MeV) and tested in hot cell at 292--325 C in Ar. The morphology, distribution, and habit planes of macroscopic and microscopic hydrides in as-irradiated and posttest cladding were determined by stereo-TEM. The type and magnitude of the residual stress produced in association with oxide-layer growth and dense hydride precipitation, and several synergistic factors that strongly influence axial-splitting behavior were analyzed. The results of the microstructural characterization and stress analyses were then correlated with axial-splitting behavior of high-burnup PWR cladding reported for simulated-RIA conditions. The effects of key test procedures and their implications for the interpretation of RIA test results are discussed

  1. Imaging results and TOF studies with axial PET detectors

    CERN Document Server

    Joram, Christian

    2013-01-01

    We have developed a fully operational PET demonstrator setup which allows true 3D reconstruction of the 511 keV photons and therefore leads to practically parallax free images. The AX-PET concept is based on thin 100 mm long scintillation crystals (LYSO), axially oriented and arranged in layers around the held of view. Layers of wavelength shifting plastic strips mounted in between the crystal layers give the axial coordinate. Both crystals and WLS strips are individually read out by G-APD (SiPM) photodetectors. The Fully scalable concept overcomes the dilemma of sensitivity versus spatial resolution which is inherent to classical PET designs. A demonstrator set-up based on two axial modules was exhaustively characterized using point-like sources, phantoms filled with radiotracer and finally rats and a mouse. The results entirely meet the performance expectations ( <2 mm FWHM in all three coordinates over the complete held of view) and also demonstrated the ability to include Compton interactions (inter-cr...

  2. Imaging results and TOF studies with axial PET detectors

    Science.gov (United States)

    Joram, Christian

    2013-12-01

    We have developed a fully operational PET demonstrator setup which allows true 3D reconstruction of the 511 keV photons and therefore leads to practically parallax free images. The AX-PET concept is based on thin 100 mm long scintillation crystals (LYSO), axially oriented and arranged in layers around the field of view. Layers of wavelength shifting plastic strips mounted in between the crystal layers give the axial coordinate. Both crystals and WLS strips are individually read out by G-APD (SiPM) photodetectors. The fully scalable concept overcomes the dilemma of sensitivity versus spatial resolution which is inherent to classical PET designs. A demonstrator set-up based on two axial modules was exhaustively characterized using point-like sources, phantoms filled with radiotracer and finally rats and a mouse. The results entirely meet the performance expectations (PET concept making use of the novel digital SiPM detectors by Philips. After reproducing comparable energy and spatial resolution on a small digital AX-PET set-up with 100 mm long crystals, we demonstrated a coincidence resolving time of about 210 ps FWHM.

  3. The New Performance Calculation Method of Fouled Axial Flow Compressor

    Directory of Open Access Journals (Sweden)

    Huadong Yang

    2014-01-01

    Full Text Available Fouling is the most important performance degradation factor, so it is necessary to accurately predict the effect of fouling on engine performance. In the previous research, it is very difficult to accurately model the fouled axial flow compressor. This paper develops a new performance calculation method of fouled multistage axial flow compressor based on experiment result and operating data. For multistage compressor, the whole compressor is decomposed into two sections. The first section includes the first 50% stages which reflect the fouling level, and the second section includes the last 50% stages which are viewed as the clean stage because of less deposits. In this model, the performance of the first section is obtained by combining scaling law method and linear progression model with traditional stage stacking method; simultaneously ambient conditions and engine configurations are considered. On the other hand, the performance of the second section is calculated by averaged infinitesimal stage method which is based on Reynolds’ law of similarity. Finally, the model is successfully applied to predict the 8-stage axial flow compressor and 16-stage LM2500-30 compressor. The change of thermodynamic parameters such as pressure ratio, efficiency with the operating time, and stage number is analyzed in detail.

  4. Multi technical analysis of wear mechanisms in axial piston pumps

    Science.gov (United States)

    Schuhler, G.; Jourani, A.; Bouvier, S.; Perrochat, J.-M.

    2017-05-01

    Axial piston pumps convert a motor rotation motion into hydraulic or pneumatic power. Their compactness and efficiency of approximately 0.9 make them suitable for actuation applications especially in aeronautics. However, they suffer a limited life due to the wear of their components. In the literature, studies of axial piston pumps deal with contact between its different elements under lubrication conditions. Nevertheless, they are more focused on analytic or numerical approaches. This study consists in an experimental analysis of worn pump components to highlight and understand wear mechanisms. Piston shoes are central components in the axial piston pump since they are involved in three tribological contacts. These three contacts are thereby studied: piston shoes/swashplate, piston shoes/pistons and piston shoes/shoes hold down plate (SHDP). To perform this analysis, helicopter hydraulic pumps after different operating times have been studied. The wear damage mechanisms and wear debris are analysed using SEM observations. 3D surface roughness measurements are then used to characterize worn surfaces. The observations reveal that in the contact between shoes and swashplate, the main wear mechanism is three-body abrasive wear due to coarse carbides removal. Between shoes and pistons, wear occurs in a less severe way and is mainly due to the debris generated in the first contact and conveyed by the lubricating fluid. In the third contact, the debris are also the prime cause of the abrasive wear and the generation of deep craters in the piston shoes.

  5. Simultaneous Rotational and Axial Flow of Nonlinear Fluids

    Science.gov (United States)

    Ashrafi, Nariman; Yektapour, Mehdi; Shafahi, Mehdi

    2017-11-01

    An axial flow is introduced to the rotational flow of pseudoplastic fluids in the gap between concentric cylinders. The outer cylinder is fixed while the inner one has simultaneous and independent rotational and translational motions. The fluid follows the Carreau-Bird model and mixed boundary conditions are imposed. The four-dimensional low-order equations resulted from Galerkin projection of the conservation of mass and momentum equations, includes highly non-linear terms in the velocity components. Without axial flow, stability of the base radial flow is lost to the vortex structure at a lower critical Taylor number, with increase of the fluid pseudoplasticity. The vortices imply onset of a supercritical bifurcation which occurs in the rotational flow of linear fluids as well. In contrast to the Newtonian case, pseudoplastic Taylor vortices lose their stability at a second critical Taylor number is reached a second critical number that corresponds to the onset of a Hopf bifurcation. The axial flow, caused by the translational motion of the inner cylinder advance each critical point on the bifurcation diagram. The flow field and viscosity maps are provided for major stability regions.

  6. Behavior of unbonded flexible risers subject to axial tension

    Science.gov (United States)

    Ren, Shao-fei; Tang, Wen-yong; Guo, Jin-ting

    2014-04-01

    Owing to nonlinear contact problems with slip and friction, a lot of limiting assumptions are made when developing analytical models to simulate the behavior of an unbonded flexible riser. Meanwhile, in order to avoid convergence problems and excessive calculating time associated with running the detailed finite element (FE) model of an unbonded flexible riser, interlocked carcass and zeta layers with complicated cross section shapes are replaced by simple geometrical shapes (e.g. hollow cylindrical shell) with equivalent orthotropic materials. But the simplified model does not imply the stresses equivalence of these two layers. To solve these problems, based on ABAQUS/Explicit, a numerical method that is suitable for the detailed FE model is proposed. In consideration of interaction among all component layers, the axial stiffness of an eight-layer unbonded flexible riser subjected to axial tension is predicted. Compared with analytical and experimental results, it is shown that the proposed numerical method not only has high accuracy but also can substantially reduce the calculating time. In addition, the impact of the lay angle of helical tendons on axial stiffness is discussed.

  7. HTS axial flux induction motor with analytic and FEA modeling

    International Nuclear Information System (INIS)

    Li, S.; Fan, Y.; Fang, J.; Qin, W.; Lv, G.; Li, J.H.

    2013-01-01

    Highlights: •A high temperature superconductor axial flux induction motor and a novel maglev scheme are presented. •Analytic method and finite element method have been adopted to model the motor and to calculate the force. •Magnetic field distribution in HTS coil is calculated by analytic method. •An effective method to improve the critical current of HTS coil is presented. •AC losses of HTS coils in the HTS axial flux induction motor are estimated and tested. -- Abstract: This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested

  8. Axial power monitoring uncertainty in the Savannah River Reactors

    International Nuclear Information System (INIS)

    Losey, D.C.; Revolinski, S.M.

    1990-01-01

    The results of this analysis quantified the uncertainty associated with monitoring the Axial Power Shape (APS) in the Savannah River Reactors. Thermocouples at each assembly flow exit map the radial power distribution and are the primary means of monitoring power in these reactors. The remaining uncertainty in power monitoring is associated with the relative axial power distribution. The APS is monitored by seven sensors that respond to power on each of nine vertical Axial Power Monitor (APM) rods. Computation of the APS uncertainty, for the reactor power limits analysis, started with a large database of APM rod measurements spanning several years of reactor operation. A computer algorithm was used to randomly select a sample of APSs which were input to a code. This code modeled the thermal-hydraulic performance of a single fuel assembly during a design basis Loss-of Coolant Accident. The assembly power limit at Onset of Significant Voiding was computed for each APS. The output was a distribution of expected assembly power limits that was adjusted to account for the biases caused by instrumentation error and by measuring 7 points rather than a continuous APS. Statistical analysis of the final assembly power limit distribution showed that reducing reactor power by approximately 3% was sufficient to account for APS variation. This data confirmed expectations that the assembly exit thermocouples provide all information needed for monitoring core power. The computational analysis results also quantified the contribution to power limits of the various uncertainties such as instrumentation error

  9. Numerical Analysis of Erosion Caused by Biomimetic Axial Fan Blade

    Directory of Open Access Journals (Sweden)

    Jun-Qiu Zhang

    2013-01-01

    Full Text Available Damage caused by erosion has been reported in several industries for a wide range of situations. In the present work, a new method is presented to improve the erosion resistance of machine components by biomimetic method. A numerical investigation of solid particle erosion in the standard and biomimetic configuration blade of axial fan is presented. The analysis consists in the application of the discrete phase model, for modeling the solid particles flow, and the Eulerian conservation equations to the continuous phase. The numerical study employs computational fluid dynamics (CFD software, based on a finite volume method. User-defined function was used to define wear equation. Gas/solid flow axial fan was simulated to calculate the erosion rate of the particles on the fan blades and comparatively analyzed the erosive wear of the smooth surface, the groove-shaped, and convex hull-shaped biomimetic surface axial flow fan blade. The results show that the groove-shaped biomimetic blade antierosion ability is better than that of the other two fan blades. Thoroughly analyze of antierosion mechanism of the biomimetic blade from many factors including the flow velocity contours and flow path lines, impact velocity, impact angle, particle trajectories, and the number of collisions.

  10. Characteristics of tip-leakage flow in an axial fan

    Science.gov (United States)

    Park, Keuntae; Choi, Haecheon; Choi, Seokho; Sa, Yongcheol

    2014-11-01

    An axial fan with a shroud generates complicated vortical structures by the interaction of the axial flow with the fan blades and shroud near the blade tips. Large eddy simulation (LES) is performed for flow through a forward-swept axial fan, operating at the design condition of Re = 547,000 based on the radius of blade tip and the tip velocity. A dynamic global model (Lee et al. 2010) is used for a subgrid-scale model, and an immersed boundary method in a non-inertial reference frame (Kim & Choi 2006) is adopted for the present simulation. It is found that two vortical structures are formed near the blade tip: the main tip leakage vortex (TLV) and the auxiliary TLV. The main TLV is initiated near the leading edge, develops downstream, and impinges on the pressure surface of the next blade, where the pressure fluctuations and turbulence intensity become high. On the other hand, the auxiliary TLV is initiated at the aft part of the blade but is relatively weak such that it merges with the main TLV. Supported by the KISTI Supercomputing Center (KSC-2014-C2-014).

  11. Hybrid Gama Emission Tomography (HGET): FY16 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Erin A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Smith, Leon E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wittman, Richard S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Campbell, Luke W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Deshmukh, Nikhil S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zalavadia, Mital A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Batie, Margo A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mozin, Vladimir V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-01

    Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX) assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.

  12. Design of electrical capacitance tomography sensors

    International Nuclear Information System (INIS)

    Yang, Wuqiang

    2010-01-01

    Electrical capacitance tomography (ECT) has been developed since the late 1980s for visualization and measurement of a permittivity distribution in a cross section using a multi-electrode capacitance sensor. While the hardware and image reconstruction algorithms for ECT have been published extensively and the topics have been reviewed, few papers have been published to discuss ECT sensors and the design issues, which are crucial for a specific application. This paper will briefly discuss the principles of ECT sensors, but mostly will address key issues for ECT sensor design, with reference to some existing ECT sensors as a good understanding of the key issues would help optimization of the design of ECT sensors. The key issues to be discussed include the number and length of electrodes, the use of external and internal electrodes, implications of wall thickness, earthed screens (including the outer screen, axial end screens and radial screens), driven guard electrodes, dealing with high temperature and high pressure, twin planes for velocity measurement by cross correlation and limitations in sensor diameter. While conventional ECT sensors are circular with the electrodes in a single plane or in twin planes, some non-conventional ECT sensors, such as square, conical and 3D sensors, will also be discussed. As a practical guidance, the procedure to fabricate an ECT sensor will be given. In the end are summary and discussion on future challenges, including re-engineering of ECT sensors. (topical review)

  13. Axial resolution of confocal Raman microscopes : Gaussian beam theory and practice

    NARCIS (Netherlands)

    Grauw, C J De; Sijtsema, N M; Otto, C; Greve, J

    1997-01-01

    A straightforward and transparent model, based on Gaussian beam optics, for the axial ro resolution of a confocal microscope is presented, A confocal Raman microscope was used to determine the axial confocality in practice. The axial response of a thin planar object was measured for three different

  14. Axial Resolution of Confocal Raman Microscopes: Gaussian Beam Theory and Practice

    NARCIS (Netherlands)

    de Grauw, C.J.; de Grauw, C.J.; Sijtsema, N.M.; Otto, Cornelis; Greve, Jan

    1997-01-01

    A straightforward and transparent model, based on Gaussian beam optics, for the axial r0 resolution of a confocal microscope is presented. A confocal Raman microscope was used to determine the axial confocality in practice. The axial response of a thin planar object was measured for three different

  15. Electric capacitance tomography and two-phase flow for the nuclear reactor safety analysis

    International Nuclear Information System (INIS)

    Lee, Jae Young

    2008-01-01

    Recently electric capacitance tomography has been developed to be used in the analysis of two-phase flow. Although its electric field is not focused as the hard ray tomography such as the X-ray or gamma ray, its convenience of easy access to the system and easy maintenance due to no requirement of radiation shielding benefits us in its application in the two-phase flow study, one of important area in the nuclear safety analysis. In the present paper, the practical technologies in the electric capacitance tomography are represented in both parts of hardware and software. In the software part, both forward problem and inverse problem are discussed and the method of regularization. In the hardware part, the brief discussion of the electronics circuits is made which provides femto farad resolution with a reasonable speed (150 frame/sec for 16 electrodes). Some representative ideal cases are studied to demonstrate its potential capability for the two-phase flow analysis. Also, some variations of the tomography such as axial tomography, and three dimensional tomography are discussed. It was found that the present ECT is expected to become a useful tool to understand the complicated three dimensional two-phase flow which may be an important feature to be equipped by the safety analysis codes. (author)

  16. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  17. Experimental Study of Axially Tension Cold Formed Steel Channel Members

    Science.gov (United States)

    Apriani, Widya; Lubis, Fadrizal; Angraini, Muthia

    2017-12-01

    Experimental testing is commonly used as one of the steps to determine the cause of the collapse of a building structure. The collapse of structures can be due to low quality materials. Although material samples have passed laboratory tests and the existing technical specifications have been met but there may be undetected defects and known material after failure. In this paper will be presented Experimental Testing of Axially Tension Cold Formed Steel Channel Members to determine the cause of the collapse of a building roof truss x in Pekanbaru. Test of tensile strength material cold formed channel sections was performed to obtain the main characteristics of Cold Formed steel material, namely ultimate tensile strength loads that can be held by members and the yield stress possessed by channel sections used in construction. Analysis of axially tension cold formed steel channel section presents in this paper was conducted through experimental study based on specificationsAnnualBook of ASTM Standards: Metal Test methods and Analitical Procedures, Section 3 (1991). The result of capacity loads experimental test was compared with design based on SNI 03-7971-2013standard of Indonesia for the design of cold formed steel structural members. The results of the yield stress of the material will be seen against the minimum allowable allowable stress range. After the test, the percentace of ultimate axial tension capacity theory has a result that is 16.46% larger than the ultimate axial tension capacity experimental. When compared with the load that must be borne 5.673 kN/m it can be concluded that 2 specimens do not meet. Yield stress of member has fulfilled requirement that wass bigger than 550 MPa. Based on the curve obtained ultimate axial tension capacity theory, results greater than experimental. The greatest voltage value (fu) is achieved under the same conditions as its yield stress. For this specimen with a melting voltage value fy = 571.5068 MPa has fulfilled the

  18. Design and axial optimization of nuclear fuel for BWR reactors

    International Nuclear Information System (INIS)

    Garcia V, M.A.

    2006-01-01

    In the present thesis, the modifications made to the axial optimization system based on Tabu Search (BT) for the axial design of BWR fuel type are presented, developed previously in the Nuclear Engineering Group of the UNAM Engineering Faculty. With the modifications what is mainly looked is to consider the particular characteristics of the mechanical design of the GE12 fuel type, used at the moment in the Laguna Verde Nucleo electric Central (CNLV) and that it considers the fuel bars of partial longitude. The information obtained in this thesis will allow to plan nuclear fuel reloads with the best conditions to operate in a certain cycle guaranteeing a better yield and use in the fuel burnt, additionally people in charge in the reload planning will be favored with the changes carried out to the system for the design and axial optimization of nuclear fuel, which facilitate their handling and it reduces their execution time. This thesis this developed in five chapters that are understood in the following way in general: Chapter 1: It approaches the basic concepts of the nuclear energy, it describes the physical and chemical composition of the atoms as well as that of the uranium isotopes, the handling of the uranium isotope by means of the nuclear fission until arriving to the operation of the nuclear reactors. Chapter 2: The nuclear fuel cycle is described, the methods for its extraction, its conversion and its enrichment to arrive to the stages of the nuclear fuel management used in the reactors are described. Beginning by the radial design, the axial design and the core design of the nuclear reactor related with the fuel assemblies design. Chapter 3: the optimization methods of nuclear fuel previously used are exposed among those that are: the genetic algorithms method, the search methods based on heuristic rules and the application of the tabu search method, which was used for the development of this thesis. Chapter 4: In this part the used methodology to the

  19. Experimental Studies on Strength Behaviour of Notched Glass/Epoxy Laminated Composites under Uni-axial and Bi-axial Loading

    Science.gov (United States)

    Guptha, V. L. Jagannatha; Sharma, Ramesh S.

    2017-11-01

    The use of FRP composite materials in aerospace, aviation, marine, automotive and civil engineering industry has increased rapidly in recent years due to their high specific strength and stiffness properties. The structural members contrived from such composite materials are generally subjected to complex loading conditions and leads to multi-axial stress conditions at critical surface localities. Presence of notches, much required for joining process of composites, makes it further significant. The current practice of using uni-axial test data alone to validate proposed material models is inadequate leading to evaluation and consideration of bi-axial test data. In order to correlate the bi-axial strengths with the uni-axial strengths of GFRP composite laminates in the presence of a circular notch, bi-axial tests using four servo-hydraulic actuators with four load cells were carried out. To determine the in-plane strength parameters, bi-axial cruciform test specimen model was considered. Three different fibre orientations, namely, 0°, 45°, and 90° are considered with a central circular notch of 10 mm diameter in the present investigation. From the results obtained, it is observed that there is a reduction in strength of 5.36, 2.41 and 13.92% in 0°, 45°, and 90° fibre orientation, respectively, under bi-axial loading condition as compared to that of uni-axial loading in laminated composite.

  20. Comparison of computed tomography with radionuclide tomography in chest diagnosis

    International Nuclear Information System (INIS)

    Takayama, Makoto; Katsuyama, Naofumi; Kawakami, Kenji; Tada, Shimpei

    1979-01-01

    Abnormal accumulation of 67 Ga citrate detected by RI tomoscan, PHO/CON, was compared with the findings of CT image by ACTA 0100 in intrathoracic diseases. Diagnostic efficacy of the RI tomoscan and CT on anatomical localization of the lesion detected by both methods were discussed. Comparative study was performed in 30 cases with malignant tumor of the lung and the mediastinum; 12 cases of primary lung cancer, 6 cases of metastatic lung cancer, 2 cases of malignant lymphoma and 10 others. Eighteen of the 30 cases showed definite evidence of enlarged mediastinal lymph nodes and/or hilar lymph nodes either by chest plain film, chest tomography or CT. Localization of 67 Ga deposit was divided into 3 groups; 1) mediastinal region, 2) hilar region and 3) lung field. The localization of lesions in each group was compared with the findings of CT image. The findings by both methods were well correlated in all cases but one. The RI tomoscan, PHO/CON, can facilitate the localization of 67 Ga accumulation by tomographic manner, and it appears to be possible to identify anatomically subdivided mediastinal lymph node groups by the combined study of RI tomoscan and CT. (author)

  1. Scanning Microwave Induced Acoustic Tomography

    National Research Council Canada - National Science Library

    Wang, Lihong V

    2002-01-01

    .... Specifically, our accomplishments include (1) an exact and an approximate time-domain reconstruction algorithm for thermoacoustic tomography in a spherical geometry was derived and published, (2...

  2. Axial level-specific regulation of neuronal development: lessons from PITX2.

    Science.gov (United States)

    Waite, Mindy R; Martin, Donna M

    2015-02-01

    Transcriptional regulation of gene expression is vital for proper control of proliferation, migration, differentiation, and survival of developing neurons. Pitx2 encodes a homeodomain transcription factor that is highly expressed in the developing and adult mammalian brain. In humans, mutations in PITX2 result in Rieger syndrome, characterized by defects in the development of the eyes, umbilicus, and teeth and variable abnormalities in the brain, including hydrocephalus and cerebellar hypoplasia. Alternative splicing of Pitx2 in the mouse results in three isoforms, Pitx2a, Pitx2b, and Pitx2c, each of which is expressed symmetrically along the left-right axis of the brain throughout development. Here, we review recent evidence for axial and brain region-specific requirements for Pitx2 during neuronal migration and differentiation, highlighting known isoform contributions. © 2014 Wiley Periodicals, Inc.

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  4. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  5. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  6. Compressive Phase Contrast Tomography

    International Nuclear Information System (INIS)

    Maia, Filipe; MacDowell, Alastair; Marchesini, Stefano; Padmore, Howard A.; Parkinson, Dula Y.; Pien, Jack; Schirotzek, Andre; Yang, Chao

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. Interference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher contrast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  7. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  8. Dynamic tomography in dentistry

    International Nuclear Information System (INIS)

    Richards, A.G.

    1976-01-01

    Dynamic tomography is a procedure in which a sandwich of eight underexposed radiographs is utilized to display sharp images of details lying in a thin layer at any chosen depth within a subject. When the sandwich of films is viewed by transmitted light, the location of this chosen layer can be moved up or down within the subject by simply mechanically moving the radiographs in a precise manner relative to each other. The amount of radiation used in exposing the eight radiographs is the same as would be used to fully expose two normal radiographs

  9. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Fercher, A.F.; Andersen, Peter E.

    2017-01-01

    Optical coherence tomography (OCT) is a technique that is used to peer inside a body noninvasively. Tissue structure defined by tissue absorption and scattering coefficients, and the speed of blood flow, are derived from the characteristics of light remitted by the body. Singly backscattered light...... technique can be realized by using ultrafast wavelength scanning light sources. For tissue imaging, the light source wavelengths are restricted to the red and near-infrared (NIR) region from about 600 to 1300 nm, the so-called therapeutic window, where absorption (μa ≈ 0.01 mm−1) is small enough. Transverse...

  10. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  11. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  12. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  13. Solar Stereoscopy and Tomography

    Directory of Open Access Journals (Sweden)

    Markus J. Aschwanden

    2011-10-01

    Full Text Available We review stereoscopic and tomographic methods used in the solar corona, including ground-based and space-based measurements, using solar rotation or multiple spacecraft vantage points, in particular from the STEREO mission during 2007--2010. Stereoscopic and tomographic observations in the solar corona include large-scale structures, streamers, active regions, coronal loops, loop oscillations, acoustic waves in loops, erupting filaments and prominences, bright points, jets, plumes, flares, CME source regions, and CME-triggered global coronal waves. Applications in the solar interior (helioseismic tomography and reconstruction and tracking of CMEs from the outer corona and into the heliosphere (interplanetary CMEs are not included.

  14. Practical adaptive quantum tomography

    Science.gov (United States)

    Granade, Christopher; Ferrie, Christopher; Flammia, Steven T.

    2017-11-01

    We introduce a fast and accurate heuristic for adaptive tomography that addresses many of the limitations of prior methods. Previous approaches were either too computationally intensive or tailored to handle special cases such as single qubits or pure states. By contrast, our approach combines the efficiency of online optimization with generally applicable and well-motivated data-processing techniques. We numerically demonstrate these advantages in several scenarios including mixed states, higher-dimensional systems, and restricted measurements. http://cgranade.com complete data and source code for this work are available online [1], and can be previewed at https://goo.gl/koiWxR.

  15. Recent RI tomography

    International Nuclear Information System (INIS)

    Katsuyama, Naofumi; Kawakami, Kenshi

    1979-01-01

    In this paper, new equipments for radionuclide tomography and recent radiopharmaceuticals with positron emission are described. Positron CT is very usefull for functional imaging. Those nucleides 11 C, 13 N and 15 O have been studied for their sake, but used as a usefull tool as tracer elements for the basic research in the fields of chemistry, bio-chemistry, biology and medicine. Also they have been utilized in the diagnosis of diseases, particularly in the non-invasive and dynamic assessment of metabolic and functional disorders in the patients. We will also describe the clinical usefullness of a commercial scanner such as the Anger multiplane tomographic scanner (PHO/CON). (author)

  16. Tumor-Induced Osteomalacia Caused by Primary Fibroblast Growth Factor 23 Secreting Neoplasm in Axial Skeleton: A Case Report

    Directory of Open Access Journals (Sweden)

    Gunjan Y. Gandhi

    2012-01-01

    Full Text Available We report the case of a 66-year-old woman with tumor-induced osteomalacia (TIO caused by fibroblast growth factor 23 (FGF-23 secreting mesenchymal tumor localized in a lumbar vertebra and review other cases localized to the axial skeleton. She presented with nontraumatic low back pain and spontaneous bilateral femur fractures. Laboratory testing was remarkable for low serum phosphorus, phosphaturia, and significantly elevated serum FGF-23 level. Magnetic resonance imaging (MRI of the lumbar spine showed a focal lesion in the L-4 vertebra which was hypermetabolic on positron emission tomography (PET scan. A computed tomography (CT guided needle biopsy showed a low grade spindle cell neoplasm with positive FGF-23 mRNA expression by reverse transcriptase polymerase chain reaction (RT-PCR, confirming the diagnosis of a phosphaturic mesenchymal tumor mixed connective tissue variant (PMTMCT. The patient elected to have surgery involving anterior resection of L-4 vertebra with subsequent normalization of serum phosphorus. Including the present case, we identified 12 cases of neoplasms localized to spine causing TIO. To our knowledge, this paper represents the first documented case of lumbar vertebra PMT causing TIO. TIO is a rare metabolic bone disorder that carries a favorable prognosis. When a lesion is identifiable, surgical intervention is typically curative.

  17. Design and axial optimization of nuclear fuel for BWR reactors; Diseno y optimizacion axial de combustible nuclear para reactores BWR

    Energy Technology Data Exchange (ETDEWEB)

    Garcia V, M.A

    2006-07-01

    In the present thesis, the modifications made to the axial optimization system based on Tabu Search (BT) for the axial design of BWR fuel type are presented, developed previously in the Nuclear Engineering Group of the UNAM Engineering Faculty. With the modifications what is mainly looked is to consider the particular characteristics of the mechanical design of the GE12 fuel type, used at the moment in the Laguna Verde Nucleo electric Central (CNLV) and that it considers the fuel bars of partial longitude. The information obtained in this thesis will allow to plan nuclear fuel reloads with the best conditions to operate in a certain cycle guaranteeing a better yield and use in the fuel burnt, additionally people in charge in the reload planning will be favored with the changes carried out to the system for the design and axial optimization of nuclear fuel, which facilitate their handling and it reduces their execution time. This thesis this developed in five chapters that are understood in the following way in general: Chapter 1: It approaches the basic concepts of the nuclear energy, it describes the physical and chemical composition of the atoms as well as that of the uranium isotopes, the handling of the uranium isotope by means of the nuclear fission until arriving to the operation of the nuclear reactors. Chapter 2: The nuclear fuel cycle is described, the methods for its extraction, its conversion and its enrichment to arrive to the stages of the nuclear fuel management used in the reactors are described. Beginning by the radial design, the axial design and the core design of the nuclear reactor related with the fuel assemblies design. Chapter 3: the optimization methods of nuclear fuel previously used are exposed among those that are: the genetic algorithms method, the search methods based on heuristic rules and the application of the tabu search method, which was used for the development of this thesis. Chapter 4: In this part the used methodology to the

  18. Geochemistry of axial seamount lavas: Magmatic relationship between the Cobb Hotspot and the Juan de Fuca Ridge

    Science.gov (United States)

    Rhodes, J. M.; Morgan, C.; Liias, R. A.

    1990-08-01

    Axial Seamount, located along the central portion of the Juan de Fuca Ridge axis and at the eastern end of the Cobb-Eickelberg Seamount Chain, is the current center of the Cobb Hotspot. The Axial Seamount lavas are transitional between N-type and E-type mid-ocean ridge basalt (MORB), characteristics that they share with lavas along the rest of the Juan de Fuca Ridge. There are, however, subtle, but distinct, differences between the seamount lavas and those of the adjoining ridge segments. These include higher Na2O, CaO, and Sr at a given MgO content and lower silica saturation in the seamount lavas as compared with the ridge lavas. Lava chemistry and bathymetry indicate that Axial Seamount is a discrete volcanic unit, with a more productive shallow magmatic plumbing system separate from the adjacent ridge segments. These high magma supply rates have sustained a continuously replenished, steady state magma reservoir that has erupted remarkably homogeneous lavas over a long time period. Despite this classic association of spreading center and hotspot volcanic activity, there is no evidence in the lavas for geochemical or isotopic enrichment typical of hotspot or mantle plume activity. The differences in composition between the Axial Seamount lavas and the Juan de Fuca Ridge lavas are attributed to melting processes rather than to any fundamental differences in their mantle source compositions. The higher magma production rates, higher Sr, and lower silica saturation in the seamount lavas relative to the ridge lavas are thought to be a consequence of melt initiation at greater depths. The melting column producing the seamount lavas is thought to be initiated in the stability field of spinel peridotite, whereas the ridge lavas are produced from a melting column initiated at shallower levels, possibly within or close to the stability field of plagioclase peridotite. Implicit in this interpretation is the conclusion that the Juan de Fuca Ridge lavas, and by analogy most

  19. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Lecomte, R.; Bentourkia, M.; Benard, F.

    2002-01-01

    Positron Emission Tomography is a sophisticated molecular imaging technique, using a special scanner, that displays the functional status of tissues in the body at the cellular level (their metabolism). It is a diagnostic scan that provides the physician with information not available with traditional anatomic studies such as CT or MRI. PET can detect changes in cell function (disease) long before they are evident as physical (anatomic) changes seen on CT or MRI. In this way PET can add important information about many diseases allowing the physician to make a diagnosis often much earlier than with anatomic imaging techniques such as CT or MRI alone. In addition, in cases where an abnormality is noted on CT or MRI, PET can help differentiate benign changes from changes due to disease. PET scanning also typically images the entire body, unlike CT/MRI which is usually broken up into specific limited body section scans. All cells use glucose as an energy source but cancer cells use much more since they are growing much faster and out of control. This is the basis of imaging with F-18 FDG glucose, the radiotracer agent use in a PET oncology study. The abnormal, accelerated glucose used by cancer cells is detected by the PET scanner that processes the emissions from the F-18 FDG glucose by abnormally high levels of metabolism (tumor)

  20. Cork quality estimation by using Compton tomography

    CERN Document Server

    Brunetti, A; Golosio, B; Luciano, P; Ruggero, A

    2002-01-01

    The quality control of cork stoppers is mandatory in order to guarantee the perfect conservation of the wine. Several techniques have been developed but until now the quality control was essentially related to the status of the external surface. Thus possible cracks or holes inside the stopper will be hidden. In this paper a new technique based on X-ray Compton tomography is described. It is a non-destructive technique that allows one to reconstruct and visualize the cross-section of the cork stopper analyzed, and so to put in evidence the presence of internal imperfections. Some results are reported and compared with visual classification.