WorldWideScience

Sample records for axial tomography evidence

  1. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  2. Axial Super-resolution Evanescent Wave Tomography

    CERN Document Server

    Pendharker, Sarang; Newman, Ward; Ogg, Stephen; Nazemifard, Neda; Jacob, Zubin

    2016-01-01

    Optical tomographic reconstruction of a 3D nanoscale specimen is hindered by the axial diffraction limit, which is 2-3 times worse than the focal plane resolution. We propose and experimentally demonstrate an axial super-resolution evanescent wave tomography (AxSET) method that enables the use of regular evanescent wave microscopes like Total Internal Reflection Fluorescence Microscope (TIRF) beyond surface imaging, and achieve tomographic reconstruction with axial super-resolution. Our proposed method based on Fourier reconstruction achieves axial super-resolution by extracting information from multiple sets of three-dimensional fluorescence images when the sample is illuminated by an evanescent wave. We propose a procedure to extract super-resolution features from the incremental penetration of an evanescent wave and support our theory by 1D (along the optical axis) and 3D simulations. We validate our claims by experimentally demonstrating tomographic reconstruction of microtubules in HeLa cells with an axi...

  3. Axial super-resolution evanescent wave tomography

    Science.gov (United States)

    Pendharker, Sarang; Shende, Swapnali; Newman, Ward; Ogg, Stephen; Nazemifard, Neda; Jacob, Zubin

    2016-12-01

    Optical tomographic reconstruction of a 3D nanoscale specimen is hindered by the axial diffraction limit, which is 2-3 times worse than the focal plane resolution. We propose and experimentally demonstrate an axial super-resolution evanescent wave tomography (AxSET) method that enables the use of regular evanescent wave microscopes like Total Internal Reflection Fluorescence Microscope (TIRF) beyond surface imaging, and achieve tomographic reconstruction with axial super-resolution. Our proposed method based on Fourier reconstruction achieves axial super-resolution by extracting information from multiple sets of three-dimensional fluorescence images when the sample is illuminated by an evanescent wave. We propose a procedure to extract super-resolution features from the incremental penetration of an evanescent wave and support our theory by 1D (along the optical axis) and 3D simulations. We validate our claims by experimentally demonstrating tomographic reconstruction of microtubules in HeLa cells with an axial resolution of $\\sim$130 nm. Our method does not require any additional optical components or sample preparation. The proposed method can be combined with focal plane super-resolution techniques like STORM and can also be adapted for THz and microwave near-field tomography.

  4. Axial super-resolution evanescent wave tomography.

    Science.gov (United States)

    Pendharker, Sarang; Shende, Swapnali; Newman, Ward; Ogg, Stephen; Nazemifard, Neda; Jacob, Zubin

    2016-12-01

    Optical tomographic reconstruction of a three-dimensional (3D) nanoscale specimen is hindered by the axial diffraction limit, which is 2-3 times worse than the focal plane resolution. We propose and experimentally demonstrate an axial super-resolution evanescent wave tomography method that enables the use of regular evanescent wave microscopes like the total internal reflection fluorescence microscope beyond surface imaging and achieve a tomographic reconstruction with axial super-resolution. Our proposed method based on Fourier reconstruction achieves axial super-resolution by extracting information from multiple sets of 3D fluorescence images when the sample is illuminated by an evanescent wave. We propose a procedure to extract super-resolution features from the incremental penetration of an evanescent wave and support our theory by one-dimensional (along the optical axis) and 3D simulations. We validate our claims by experimentally demonstrating tomographic reconstruction of microtubules in HeLa cells with an axial resolution of ∼130  nm. Our method does not require any additional optical components or sample preparation. The proposed method can be combined with focal plane super-resolution techniques like stochastic optical reconstruction microscopy and can also be adapted for THz and microwave near-field tomography.

  5. Computerized axial tomography in clinical pediatrics.

    Science.gov (United States)

    McCullough, D C; Kufta, C; Axelbaum, S P; Schellinger, D

    1977-02-01

    Computerized axial tomography (CAT), a noninvasive radiologie method, provides a new dimension in screening and diagnosis of intracranial pathology. Evaluation of 725 scans in infants and children demonstrates that CAT may be performed with negligible risk, although sedation and restraint are essential to the successful performance of studies in children under 6 years of age. CAT is the preferred initial diagnostic method in suspected hydrocephalls and is accurate in the detection and precise localization of brain tumors. The management of hydrocephalus and brain tumors has been significantly altered by the availability of CAT. Few invasive neuroradiologic procedures are required and pneumography is especially curtailed. Serial scanning is the best available method of monitoring ventricular alterations in hydrocephalus, tumor size during radiotherapy or chemotherapy, and postoperative recurrence of benign neoplasms. Complex intracranial anomalies are detectable with computerized tomography, but complete definition of pathology often requires angiography and air studies. Limited clinical experience in detecting neonatal intraventricular hemorrhage suggests that CAT will be a valuable tool for futlre investigations of that problem.

  6. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  7. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  8. Computed tomography of the sella turcica content in coronal and axial plane

    Energy Technology Data Exchange (ETDEWEB)

    Lovrencic, M.; Kalousek, M.; Klaric, R.; Sekso, M.

    1984-10-01

    Computed tomography of the pituitary fossa in the axial and coronal plane have been performed in 40 patients. The use of both planes has improved diagnostic accuracy through a more exact spatial demonstration. The method has also been reliable in the detection of pituitary microadenomas. The use of both planes has a limited diagnostic accuracy due artefacts in coronal plane.

  9. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  10. Analysis and calibration of stage axial vibration for synchrotron radiation nanoscale computed tomography.

    Science.gov (United States)

    Fu, Jian; Li, Chen; Liu, Zhenzhong

    2015-10-01

    Synchrotron radiation nanoscale computed tomography (SR nano-CT) is a powerful analysis tool and can be used to perform chemical identification, mapping, or speciation of carbon and other elements together with X-ray fluorescence and X-ray absorption near edge structure (XANES) imaging. In practical applications, there are often challenges for SR nano-CT due to the misaligned geometry caused by the sample stage axial vibration. It occurs quite frequently because of experimental constraints from the mechanical error of manufacturing and assembly and the thermal expansion during the time-consuming scanning. The axial vibration will lead to the structure overlap among neighboring layers and degrade imaging results by imposing artifacts into the nano-CT images. It becomes worse for samples with complicated axial structure. In this work, we analyze the influence of axial vibration on nano-CT image by partial derivative. Then, an axial vibration calibration method for SR nano-CT is developed and investigated. It is based on the cross correlation of plane integral curves of the sample at different view angles. This work comprises a numerical study of the method and its experimental verification using a dataset measured with the full-field transmission X-ray microscope nano-CT setup at the beamline 4W1A of the Beijing Synchrotron Radiation Facility. The results demonstrate that the presented method can handle the stage axial vibration. It can work for random axial vibration and needs neither calibration phantom nor additional calibration scanning. It will be helpful for the development and application of synchrotron radiation nano-CT systems.

  11. Donkey dental anatomy. Part 1: Gross and computed axial tomography examinations.

    Science.gov (United States)

    Du Toit, N; Kempson, S A; Dixon, P M

    2008-06-01

    Post-mortem examination of 19 donkey skulls showed that donkeys have a greater degree of anisognathia (27% width difference between upper and lower jaws) compared to horses (23%). Teeth (n=108) were collected from 14 skulls and examined grossly and by computed axial tomography (CAT). A greater degree of peripheral enamel infolding was found in mandibular cheek teeth (CT) compared to maxillary CT (P16 years) than in the younger (dental anatomy was shown to be largely similar to that described in horses.

  12. Lateral and axial measurement differences between spectral-domain optical coherence tomography systems

    Science.gov (United States)

    Folgar, Francisco A.; Yuan, Eric L.; Farsiu, Sina; Toth, Cynthia A.

    2014-01-01

    We assessed the reproducibility of lateral and axial measurements performed with spectral-domain optical coherence tomography (SDOCT) instruments from a single manufacturer and across several manufacturers. One human retina phantom was imaged on two instruments each from four SDOCT platforms: Zeiss Cirrus, Heidelberg Spectralis, Bioptigen SDOIS, and hand-held Bioptigen Envisu. Built-in software calipers were used to perform manual measurements of a fixed lateral width (LW), central foveal thickness (CFT), and parafoveal thickness (PFT) 1 mm from foveal center. Inter- and intraplatform reproducibilities were assessed with analysis of variance and Tukey-Kramer tests. The range of measurements between platforms was 5171 to 5290 μm for mean LW (p<0.001), 162 to 196 μm for mean CFT (p<0.001), and 267 to 316 μm for mean PFT (p<0.001). All SDOCT platforms had significant differences between each other for all measurements, except LW between Bioptigen SDOIS and Envisu (p=0.27). Intraplatform differences were significantly smaller than interplatform differences for LW (p=0.020), CFT (p=0.045), and PFT (p=0.004). Conversion factors were generated for lateral and axial scaling between SDOCT platforms. Lateral and axial manual measurements have greater variance across different SDOCT platforms than between instruments from the same platform. Conversion factors for measurements from different platforms can produce normalized values for patient care and clinical studies.

  13. X-ray detectors in axial computed tomography development; Sensori di radiazioni X negli sviluppi della tomografia assiale computerizzata

    Energy Technology Data Exchange (ETDEWEB)

    Gislon, R.; Imperiali, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione

    1996-12-01

    The increase of potentially of axial computed tomography as a non destructive investigation method in industrial field is particularly tied to the development of the X-rays detectors. The transition from the first gas ionization detectors to the last semiconductor detectors has indeed dramatically increased the performances of tomographic systems. In this report, after a quick analysis of fundamental principles of tomography, the most significant parameters for a detector to be used in a tomographic system are reviewed. The examination of the principal kinds of detectors that have been up to now used, with their working schemes, allows to delineate their characteristics and so to compare them with the ideal detector sketched above. The necessity of using high definition arrays brings to put into evidence the inadequacy of both gas and liquid ionization detectors and also of those types of light conversion devices which utilize for signal amplification a photomultiplier tube. Systems based on charge coupled devices or on a light conversion obtained with semiconductor photodiode arrays are definitely to be preferred. The progress of the last years in microelectronic technologies has brought great improvements in this field.

  14. Spectral estimation optical coherence tomography for axial super-resolution (Conference Presentation)

    Science.gov (United States)

    Liu, Xinyu; Yu, Xiaojun; Wang, Nanshuo; Bo, En; Luo, Yuemei; Chen, Si; Cui, Dongyao; Liu, Linbo

    2016-03-01

    The sample depth reflectivity profile of Fourier domain optical coherence tomography (FD-OCT) is estimated from the inverse Fourier transform of the spectral interference signals (interferograms). As a result, the axial resolution is fundamentally limited by the coherence length of the light source. We demonstrate an axial resolution improvement method by using the autoregressive spectral estimation technique to instead of the inverse Fourier transform to analyze the spectral interferograms, which is named as spectral estimation OCT (SE-OCT). SE-OCT improves the axial resolution by a factor of up to 4.7 compared with the corresponding FD-OCT. Furthermore, SE-OCT provides a complete sidelobe suppression in the point-spread function. Using phantoms such as an air wedge and micro particles, we prove the ability of resolution improvement. To test SE-OCT for real biological tissue, we image the rat cornea and demonstrate that SE-OCT enables clear identification of corneal endothelium anatomical details ex vivo. We also find that the performance of SE-OCT is depended on SNR of the feature object. To evaluate the potential usage and define the application scope of SE-OCT, we further investigate the property of SNR dependence and the artifacts that may be caused. We find SE-OCT may be uniquely suited for viewing high SNR layer structures, such as the epithelium and endothelium in cornea, retina and aorta. Given that SE-OCT can be implemented in the FD-OCT devices easily, the new capabilities provided by SE-OCT are likely to offer immediate improvements to the diagnosis and management of diseases based on OCT imaging.

  15. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  16. Seeing the Axial Line: Evidence from Wayfinding Experiments

    Directory of Open Access Journals (Sweden)

    Beatrix Emo

    2014-07-01

    Full Text Available Space-geometric measures are proposed to explain the location of fixations during wayfinding. Results from an eye tracking study based on real-world stimuli are analysed; the gaze bias shows that attention is paid to structural elements in the built environment. Three space-geometric measures are used to explain the data: sky area, floor area and longest line of sight. Together with the finding that participants choose the more connected street, a relationship is proposed between the individual cognitive processes that occur during wayfinding, relative street connectivity measured through space syntactic techniques and the spatial geometry of the environment. The paper adopts an egocentric approach to gain a greater understanding on how individuals process the axial map.

  17. [Correlation between diagnostic hypothesis and result of cranial computed axial tomography].

    Science.gov (United States)

    Nóvak, E M; Terabe, F; Nasimoto, A L; Carvalho, P H; Loper, A D; Büchele, F S; Nogara, J C

    2001-09-01

    The use of computed axial tomography (CT) in the investigation of neurologic disorders is attractive for its disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 +/- 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36.2%), Emergency room (17.4%), Pediatric Neurology (16.9%) and Internal Medicine (5.9%). The CT was more indicated in cases of seizures (30%), headache (26.2%), motor impairment (20.2%) and reduction of conscience level (16.9%). The main hypothetic diagnosis were "to discard anatomic lesions" (9.0%), not specified stroke (8.2%) and neurocisticercosis (8.2%). The result of the CT was normal in 50.4% of the exams specially those requested in cases of headache (94.4%), seizures (71.4%) and "to discard anatomic lesions"(66.7%). The more frequently CT abnormalities were hydrocephalus (5.4%), ischemic stroke (5.4%) and neoplasm (3.5%) The greatest rates of correlation were among those to discard anatomic lesions (66,7%), hydrocephalus (50%), ischemic stroke (50%) and hematoma (50%). We concluded that CT is more helpful if more clinical data is provided in the request form, so aiding the radiologist in the final report.

  18. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    Energy Technology Data Exchange (ETDEWEB)

    Dugas, Alexandre; Therasse, Eric; Kauffmann, Claude; Tang, An [University of Montreal, Department of Radiology, Centre Hospitalier de l' Universite de Montreal (CHUM) and CHUM Research Center (CRCHUM) (Canada); Elkouri, Stephane [University of Montreal, Department of Surgery, Centre Hospitalier de l' Universite de Montreal (CHUM) (Canada); Nozza, Anna [Institut de Cardiologie de Montreal, Montreal Heart Institute Coordinating Centre (Canada); Giroux, Marie-France; Oliva, Vincent L.; Soulez, Gilles, E-mail: gilles.soulez.chum@ssss.gouv.qc.ca [University of Montreal, Department of Radiology, Centre Hospitalier de l' Universite de Montreal (CHUM) and CHUM Research Center (CRCHUM) (Canada)

    2012-08-15

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001-0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662-0.780) and single-plane MPR images (0.772-0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

  19. Computerized axial tomography of the chest for visualization of ''absent'' pulmonary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sondheimer, H.M. (Upstate Medical Center, Syracuse, NY); Oliphant, M.; Schneider, B.; Kavey, R.E.W.; Blackman, M.S.; Parker, F.B. Jr.

    1982-05-01

    To expand the search for central pulmonary arteries in six patients with absence of cardiac-pulmonary continuity, computerized axial tomography (CAT) of the chest was performed. The CAT scans were compared with previous arteriograms and pulmonary vein wedge angiograms. Three patients with type IV truncus arteriosus were studied, and none had a central, right or left pulmonary artery on CAT scan. However, two patients with tetralogy of Fallot with pulmonary atresia and a patent ductus arteriosus to the right lung demonstrated the presence of a left pulmonary artery. In addition, one child with truncus arteriosus with ''absent'' left pulmonary artery demonstrated a left pulmonary artery on the CAT scan. The CAT scan may therefore enhance our ability to search for disconnected pulmonary arteries in children with complex cyanotic congenital heart disease.

  20. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder...... cancer were referred to preoperative staging including MRI and ¹⁸F-FDG PET/CT. Eighteen out of 48 patients underwent radical cystoprostatectomy including removal of lymph nodes for histology, and were included in the study. Values of ¹⁸F-FDG PET/CT and MRI for regional N staging were compared...... to histopathology findings, the gold standard. Results. ¹⁸F-FDG PET/CT and MRI were performed in 18 patients. The specificities for detection of lymph-node metastases for MRI and ¹⁸F-FDG PET/CT were 80% (n = 15) and 93.33% (n = 15), respectively. The negative predictive values were 80% (n = 15) and 87.5% (n = 16...

  1. Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

    Science.gov (United States)

    da Silva, Nathália Cristine; Barriviera, Maurício; Junqueira, José Luiz Cintra; Panzarella, Francine Kühl

    2017-01-01

    Purpose This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. Materials and Methods A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. Results All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. Conclusion It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators. PMID:28361024

  2. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

    Science.gov (United States)

    Andersson, P.; Andersson-Sunden, E.; Sjöstrand, H.; Jacobsson-Svärd, S.

    2014-08-01

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm-1, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication

  3. Radiation dose in computed tomography of the pelvis: comparison of helical and axial scanning.

    Science.gov (United States)

    Pitman, A G; Budd, R S; McKenzie, A F

    1997-11-01

    An anthropomorphic Rando phantom was used to compare radiation doses sustained during helical and conventional axial CT of the pelvis. The values obtained with the Rando phantom were validated against cadaveric phantoms, and show good agreement. For the authors' particular CT unit, helical scanning was found to deliver a lower radiation dose than conventional axial scanning. This was most prominent at 1.0-s tube rotation times (average dose ratio 1.24). For realistic scanning parameters and exposure factors, the ratio of radiation dose to pelvic organs can be expected to lie in the range of 40-100 mGy. The whole-body effective dose (ED) depends on selection of scanning parameters and patients anatomy. In a favourable case scenario, the ED for CT scanning of the pelvis in a male can be expected to be between 10 and 20 mSv if the scrotum is not included in the radiation field, while the ED in a female will be approximately 20 mSv. An examination of scatter radiation fall-off curves from a single slice shows that the spread of scatter radiation is only marginally affected by slice thickness. A total of 10-12 cm of human soft tissue acts as a good barrier against internal scattered radiation. The use of such scatter fall-off curves, together with manufacturers' dosimetry specifications, allows a fast estimate of absorbed dose.

  4. Usefulness of thin axial images of computerized tomography angiography for surgery on paraclinoid carotid artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Nagasawa, Shiro; Deguchi, Jun; Arai, Motohiro; Tanaka, Hideo; Ohta, Tomio [Osaka Medical Coll., Takatsuki (Japan)

    1995-08-01

    Ten cases involving a total of 13 aneurysms located in the clinoid portion of the carotid artery were included in this study according to Al-Radham`s classification. Non-ionic, iodinated contrast solution, a total of 2 ml/ kg, was intravenously infused at a rate of 2 ml/sec. Helical scanning was begun 30 seconds after initiating the infusion, 1 mm pitch/1.5 second/rotation. 3-D images and original images of axial slices were compared to conventional angiography, DSA and surgical findings. The 3-D images of 3-D-CT-A were able to demonstrate both aneurysms located in the C2 segment of the carotid artery (groups I and II), and five of nine carotid cave aneurysms (group III). The aneurysms located more proximally (group IV or V) could not be visualized. Original axial images of 3-D-CT-A, on the other hand, clearly demonstrated the C2, C3 and C4 segment of the carotid artery, dome and neck of the aneurysm and bone structures such as the anterior clinoid process (ACP) and sella turcica in all cases. 3-D-CT-A is known to have several advantages in cases involving common locations around the Willis ring: multiple aneurysms on a single approach line, a giant aneurysm whose neck is not clearly demonstrated, or bony structures disturbing the access to aneurysms. However, it has been generally regarded that 3-D-CT-A is of little value for diagnosing paraclinoid internal carotid artery aneurysms. This study demonstrated that a series of original axial images of 3-D-CT-A provides excellent information regarding surgical anatomy; each segment of the carotid artery, neck and dome of the aneurysms, the ACP and its topographic relations to the aneurysm, calcification, and so forth. Since aneurysms can be visualized even in the presence of clips applied to adjacent aneurysms, original images are useful for the follow-up of these specific untreated aneurysms. (J.P.N.).

  5. [Brain changes in patients on chronic hemodialysis recorded by computed axial tomography].

    Science.gov (United States)

    Todorov, V; Penkova, S; Boneva, R; Kiuchukov, G

    1988-01-01

    The brain changes in patients with chronic renal failure treated by chronic hemodialysis were studied with the help of computed tomography. The results showed the development of internal hydrocephalus in the patients in whose treatment "hard" water was used. In some of these patients the hydrocephalus was accompanied by clinical manifestations of the "disequilibrium" syndrome and the "hard water" syndrome. The patients dialyzed with "soft" water showed no brain changes and clinical signs. Hydrocephalus is probably the main pathogenetic factor for the development of the "hard water" syndrome which later develops in dialysis encephalopathy.

  6. Axial resolution and the value of interpolating scan in multislice positron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Senda, M.; Yonekura, Y.; Tamaki, N.; Tanaka, Y.; Komori, M.; Minato, K.; Torizuka, K.

    1985-05-01

    The authors have calculated the aperture function of a positron computed tomograph (PCT) with computer simulation and evaluated both theoretically and experimentally the axial resolution of a multislice PCT, Positologica III, which has 7 slices at the interval of 16mm. The axial point spread function (PSF) was approximately a triangle at or near the center of the field and the sensitivity for the slice decreased significantly as the source moved away off the image plane. Accordingly there are low sensitivity areas between an in-plane and the adjacent cross-plane. In experiments using a myocardial phantom, a small myocardial defect of 1cm diameter could not be detected when dropped into the gap between slices, although the machine had sufficiently high resolution to deliniate it if it was on the image plane. When long-axis images of the ''myocardium'' were reconstructed three-dimensionally from the images obtained in single object position, the ''inferior wall'' dropped into the gap and disappeared. In clinical myocardial scan with N-13 labeled ammonia in a normal volunteer, a false positive defect appeared in the inferior wall. However, when the object is slided half the slice interval to perform the ''interpolating'' scan and the two sets of images were interlaced with each other, no artifacts appeared. These results have suggested that the invisible regions between slices may be clinically significant if the object is thin enough in z-axis. In order to fill up the gaps between slices, it is valuable to perform the interpolating scan.

  7. Computer Axial Tomography and evoked potentials as predictors of clinical improvement in cranioencephalic trauma. Tomografía axial computarizada y potenciales evocados como predictores de mejoría clínica en el traumatismo craneoencefálico.

    Directory of Open Access Journals (Sweden)

    José Arteaga Bermúdez

    2009-03-01

    Full Text Available Background: Mortality predictors in cranioencephalic trauma reveal mortality chances or possible severe sequels; but they do not predict rehabilitation possibilities. Objective: To assess the effectiveness of Computer Axial Tomography and evoked potentials to predict clinical improvement six moths after cranioencephalic trauma. Method: Prospective, observational, descriptive study developed from January to December, 2006, to assess the effectiveness of Computer Axial Tomography and evoked potentials as possible predictors of clinical improvement in an adult population (64 patients of Cienfuegos province suffering from cranioencephalic trauma. Results: Patients with less serious lesions had three times more chances of clinical improvement. Patients with normal evoked potentials had greater chances of clinical improvement compared with those presenting irregular evoked potentials. Conclusions: The study showed the predictive value of computer axial tomography and evoked potentials related with clinical improvement in patients with cranioencephalic trauma.Fundamento: Los factores predictores de mortalidad del traumatismo craneoencefálico pronostican posibilidades de morir o quedar con secuelas graves, pero no predicen el grado de recuperabilidad. Objetivo: Analizar la efectividad de la tomografía axial computarizada de cráneo inicial y de los potenciales evocados en función de la predicción de mejoría clínica a los 6 meses de evolución del traumatismo craneoencefálico. Método: Estudio descriptivo, observacional y prospectivo realizado desde enero y hasta diciembre de 2006, que estudió la efectividad de la tomografía axial computarizada y de los potenciales evocados como posibles factores predictivos de mejoría clínica en la población adulta (64 pacientes de la provincia de Cienfuegos que sufri

  8. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    Directory of Open Access Journals (Sweden)

    Akinobu Watanabe

    Full Text Available Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT imaging. Complementary examination of external and internal osteology reveals (1 highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2 anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3 apneumatic sacral vertebrae; and (4 a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  9. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Radiologia - Neuradiologia dell’Ospedale Regionale Umberto I, Anconal(2 in 1976, was approximately 60 thousand lira. In 1976, this centre examined a total...Radiology 121, 189-195 (1976). 45) E.Benassi, G. uliani - Elementi di radiologia medica ed. Minerva Medica 1975. 46) W.Swindell, H.H.Barrett

  10. Diagnostic Sensitivity of Multidetector-Row Spiral Computed Tomography Angiography in the Evaluation of Type-II Endoleaks and their Source: Comparison between Axial Scans and Reformatting Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saba, L.; Pascalis, L.; Montisci, R.; Sanfilippo, R.; Mallarini, G. (Depts. of Radiology and Vascular Surgery, Azienda Ospedaliero-Universitaria di Cagliari, Polo di Monserrato, Monserrato, Cagliari (Italy))

    2008-07-15

    Background: After endovascular stent-graft placement, several complications may occur. Retrograde filling of the aneurysm (type-II endoleak) is the most common. Purpose: To evaluate the accuracy, image quality, and interobserver agreement of multidetector-row spiral computed tomography angiography (MDCTA) in the diagnosis of type-II endoleak, by using various types of reformatting techniques in comparison to regular axial images. Material and Methods: Twenty-four patients who had had endovascular repair of an infrarenal abdominal aortic aneurysm with stent graft were retrospectively studied. In 12 of 24 patients, a type-II endoleak was found. CT scans were obtained after intravenous administration of 130 ml of nonionic contrast material using a 4-6-ml/s flow rate. All patients were investigated with axial scans, multiplanar reconstruction (MPR), maximum intensity projection (MIP), shaded-surface display (SSD), and volume-rendering (VR) techniques. For each patient and for each reconstruction method, the image quality of the scans was scored as 0 for bad quality, 1 for poor quality, 2 for good quality, and 3 for excellent quality images. Two radiologists reviewed the CT images independently. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each reconstruction method, with the axial images as the reference method. Interobserver agreement and kappa value were also recorded. Results: MPR showed the highest sensitivity (83% and 67% for observers 1 and 2, respectively), PPV (91% and 80% for observers 1 and 2, respectively), and NPV (85% and 71% for observers 1 and 2, respectively), whereas VR showed the highest specificity (92% for both observer 1 and 2). Conclusion: Reformatting techniques provide good-quality images; nevertheless, their efficacy in the study of type-II endoleak was found to be suboptimal in comparison to regular axial images. The MPR technique is probably the best choice in conjunction

  11. Are Hox genes ancestrally involved in axial patterning? Evidence from the hydrozoan Clytia hemisphaerica (Cnidaria.

    Directory of Open Access Journals (Sweden)

    Roxane Chiori

    Full Text Available BACKGROUND: The early evolution and diversification of Hox-related genes in eumetazoans has been the subject of conflicting hypotheses concerning the evolutionary conservation of their role in axial patterning and the pre-bilaterian origin of the Hox and ParaHox clusters. The diversification of Hox/ParaHox genes clearly predates the origin of bilaterians. However, the existence of a "Hox code" predating the cnidarian-bilaterian ancestor and supporting the deep homology of axes is more controversial. This assumption was mainly based on the interpretation of Hox expression data from the sea anemone, but growing evidence from other cnidarian taxa puts into question this hypothesis. METHODOLOGY/PRINCIPAL FINDINGS: Hox, ParaHox and Hox-related genes have been investigated here by phylogenetic analysis and in situ hybridisation in Clytia hemisphaerica, an hydrozoan species with medusa and polyp stages alternating in the life cycle. Our phylogenetic analyses do not support an origin of ParaHox and Hox genes by duplication of an ancestral ProtoHox cluster, and reveal a diversification of the cnidarian HOX9-14 genes into three groups called A, B, C. Among the 7 examined genes, only those belonging to the HOX9-14 and the CDX groups exhibit a restricted expression along the oral-aboral axis during development and in the planula larva, while the others are expressed in very specialised areas at the medusa stage. CONCLUSIONS/SIGNIFICANCE: Cross species comparison reveals a strong variability of gene expression along the oral-aboral axis and during the life cycle among cnidarian lineages. The most parsimonious interpretation is that the Hox code, collinearity and conservative role along the antero-posterior axis are bilaterian innovations.

  12. Iterative Reconstruction of Computed Axial Tomography images based on GPUs; Reconstruccion Iterativa de Imagenes TAC basada en GPUs

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, V.; Florez, L. A.; Mayo, P.; Rodenas, F.; Verdu, G.

    2013-07-01

    Although widely used in nuclear medicine (gamma-cameras, SPECT-single photon emission computed tomography, positron emission tomography, PET), the iterative image reconstruction is not widespread in Computed tomography (CT). The biggest reason for this is that the data set required in TAC is much higher than in nuclear medicine and iterative reconstruction is computationally very intensive. The graphics processing units (GPUs) provide the possibility to reduce the high computational cost of rebuilding in an effective way. The objective of this work is to develop image reconstruction algorithm based on GPUs.

  13. Subduction or delamination beneath the Apennines? Evidence from regional tomography

    NARCIS (Netherlands)

    Koulakov, I.; Jakovlev, A.; Zabelina, I.; Roure, F.; Cloetingh, S.; El Khrepy, S.; Al-Arifi, N.

    2015-01-01

    In this study we present a new regional tomography model of the upper mantle beneath Italy and the surrounding area derived from the inversion of travel times of P and S waves from the updated International Seismological Centre (ISC) catalogue. Beneath Italy, we identify a high-velocity anomaly whic

  14. Pathological investigation of caries and occlusal pulpar exposure in donkey cheek teeth using computerised axial tomography with histological and ultrastructural examinations.

    Science.gov (United States)

    Toit, Nicole du; Burden, Faith A; Kempson, Sue A; Dixon, Padraic M

    2008-12-01

    Post-mortem examination of 16 donkey cheek teeth (CT) with caries (both peripheral and infundibular) and pulpar exposure were performed using computerised axial tomography (CAT), histology and scanning electron microscopy. CAT imaging was found to be useful to assess the presence and extent of caries and pulp exposure in individual donkey CT. Histology identified the loss of occlusal secondary dentine, and showed pulp necrosis in teeth with pulpar exposure. Viable pulp was present more apically in one exposed pulp horn, with its occlusal aspect sealed off from the exposed aspect of the pulp horn by a false pulp stone. Scanning electron microscopy showed the amelo-cemental junction to be a possible route of bacterial infection in infundibular cemental caries. The basic pathogenesis of dental caries in donkeys appears very similar to its description in other species.

  15. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  16. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  17. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E. (National Institute of Aging, Baltimore, MD (USA))

    1990-11-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas.

  18. Evidence supporting the use of cone-beam computed tomography in orthodontics.

    NARCIS (Netherlands)

    Vlijmen, O.J.C. van; Kuijpers, M.A.R.; Berge, S.J.; Schols, J.G.J.H.; Maal, T.J.J.; Breuning, H.; Kuijpers-Jagtman, A.M.

    2012-01-01

    BACKGROUND: The authors conducted a systematic review of cone-beam computed tomography (CBCT) applications in orthodontics and evaluated the level of evidence to determine whether the use of CBCT is justified in orthodontics. TYPES OF STUDIES REVIEWED: The authors identified articles by searching th

  19. Retinal optical coherence tomography at 1 μm with dynamic focus control and axial motion tracking.

    Science.gov (United States)

    Cua, Michelle; Lee, Sujin; Miao, Dongkai; Ju, Myeong Jin; Mackenzie, Paul J; Jian, Yifan; Sarunic, Marinko V

    2016-02-01

    High-resolution optical coherence tomography (OCT) retinal imaging is important to noninvasively visualize the various retinal structures to aid in better understanding of the pathogenesis of vision-robbing diseases. However, conventional OCT systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking OCT system with automatic focus optimization for high-resolution, extended-focal-range clinical retinal imaging by incorporating a variable-focus liquid lens into the sample arm optics. Retinal layer tracking and selection was performed using a graphics processing unit accelerated processing platform for focus optimization, providing real-time layer-specific en face visualization. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the retina and optic nerve head, from which we extracted clinically relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.

  20. Sensitivity of computer assisted radionuclide angiography in transient ischemic attack and prolonged reversible ischemic neurological deficit. Comparison with findings in radiographic angiography and transmission computerized axial tomography

    Energy Technology Data Exchange (ETDEWEB)

    Buell, U.; Scheid, K.F.; Lanksch, W.; Kleinhans, E.; Ulbert, V.; Reger, U.; Rath, M.; Moser, E.A.

    Computer assisted radionuclide angiography (CARNA) with 99mTc-DTPA was employed to study 143 patients with transient ischemic attacks (TIA) and 79 patients with prolonged reversible ischemic neurologic deficit (PRIND). The results of CARNA were compared with findings from radiographic angiography (RGA) in 173 patients and with findings in transmission computerized axial tomography (T-CAT) in 154 patients. In patients with TIA, CARNA showed a hemispherical perfusion deficit in 74.8%, and with PRIND 87.3%. This deficit, determined as the relative difference between the involved and the non-involved hemisphere, was significantly (p less than 0.0025) greater in PRIND (minus 23%) than in TIA (minus 17%). Sensitivity of CARNA was independent of the interval from ictus to examination for more than 4 months. RGA in TIA revealed true positives in 82.0%, in PRIND it was 89.5%. T-CAT was positive in TIA in only 16.8% but in PRIND it was 64.4%. Combined sensitivities in TIA (92.4%) and in PRIND (94.0%) were highest with the combination of CARNA and RGA. However, in PRIND the combination of non-invasive methods (CARNA and T-CAT) revealed 93.2% positive findings. Combinations of these evaluation methods may be used to detect cerebrovascular disease in patients with such dysfunction.

  1. Assimilation of Seawater in Basaltic Magmas: Evidence Found in a Lava Pillar From Axial Seamount, Juan de Fuca Ridge

    Science.gov (United States)

    Schiffman, P.; Zierenberg, R.; Chadwick, W. W.; Clague, D. A.

    2008-12-01

    A lava pillar formed during the 1998 eruption at Axial Seamount exhibits compositional and textural evidence consistent with the direct assimilation of seawater under magmatic conditions. Glass immediately adjacent to anastomosing microfractures within 1 cm of the inner pillar wall is oxidized and significantly enriched in both Na and Cl (and depleted in Fe and K) with respect to that in selvages from the (unaffected) outer pillar wall. The affected glass contains up to 1 wt. % Cl and is enriched by ca. 2 wt. % Na2O relative to unaffected glass, consistent with a nearly 1:1 (molar) assimilation of NaCl. Glass not adjacent to microfractures in the inner pillar wall is depleted in Na, but enriched in K, with respect to the NaCl-enriched, inner pillar wall glass and the unaffected outer pillar wall glass. The 87Sr/86Sr ratio of the NaCl-enriched glass (ca. 0.704 +/- .001), as determined by LA ICPMS, is slightly elevated with respect to that of unaffected glass (ca. .703) consistent with the incorporation of a seawater-derived fluid. The presence of tiny (< 10 mm) grains of Cu-Fe- and Fe-sulfides as well as elemental Ni, Ag, and Au in the Na-depleted, K-enriched glass of the inner pillar wall implies significant reduction of this glass, presumably by hydrogen generated during seawater assimilation and oxidation of magma adjacent to microfractures. We interpret that the chemical anomalies we see in the glass of the interior pillar wall are caused by nearly instantaneous assimilation of seawater into the magma during pillar growth. Other lava pillars we have examined from Axial Seamount and elsewhere on the Juan de Fuca Ridge do not display similar features, although we have not examined a statistically significant number of samples to ascertain how widespread a process this is for seawater assimilation.

  2. Correlação entre hipótese diagnóstica e laudo de tomografia axial computadorizada craniana Correlation between diagnostic hypothesis and result of cranial computed axial tomography

    Directory of Open Access Journals (Sweden)

    Edison Matos Nóvak

    2001-09-01

    Full Text Available Para avaliar a utilização da tomografia axial computadorizada craniana (TC em nosso meio, analisamos as solicitações de 367 exames consecutivos no período compreendido entre 07/1995 e 07/1996. Houve ampla variação da faixa etária, com média de 31,7 ± 22,9 anos. As especialidades que mais solicitaram o exame foram: Neurologia (36,2%, Pronto Atendimento (17,4%, Neuropediatria (16,9% e Clínica Médica (5,9%. As indicações mais frequentes para o exame foram: convulsão (30%, cefaléia (26,2%, déficit motor (20,2% e redução do nível de consciência (16,9%. As "hipóteses" aventadas com maior frequência foram: afastar lesão estrutural (9,0%, acidente vascular não discriminado (8,2% e neurocisticercose (8,2%. O laudo da TC foi normal em 50,4% dos exames. Os laudos anormais mais frequentes foram: hidrocefalia (5,4%, acidente vascular isquêmico (5,4% e neoplasia (3,5%. As maiores taxas de achados normais foram encontradas nas "hipóteses" de cefaléia (94,4%, convulsão (71,4% e afastar lesão estrutural (66,7%. Os maiores índices de acerto entre hipótese e laudo foram encontrados nas situações de "afastar lesões estruturais" (66,7%, hidrocefalia (50%, acidente vascular cerebral isquêmico (50% e hematoma (50%. Concluimos que a utilização de um recurso auxiliar de diagnóstico como a TC cumpre melhor ainda a sua função se o requisitante do exame preencher com clareza e detalhamento o pedido do exame.The use of computed axial tomography (CT in the investigation of neurologic disorders is attractive for his disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 ± 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36

  3. Study of the relationship and importance of clinical semiology, axial computed tomography and electroneuromyography in lumbar radioculopathies Estudo da relação e da importância entre a semiologia clínica, tomografia axial computadorizada e eletroneuromiografia nas radiculopatias lombares

    Directory of Open Access Journals (Sweden)

    Emílio Cezar Mamede Murade

    2002-12-01

    Full Text Available The authors evaluated forty-three patients with clinical suspect of lumbar radiculopathy caused by disk hernia, concerning to clinical semiology, computed tomography and electromyography were studied and their correlations. The clinical semiology was altered in 100,0% of the patients, the computed tomography in 90,7% and the electromyography in 88,7%. The correlation among the three exams didn´t show any prevalency among any of the possible associations. The authors emphasize the importance of clinical semiology, computed tomography and electromyography for a more accurate diagnosis of lumbar radiculopathy following by disk hernia.Os autores estudaram 43 pacientes com suspeita clínica de radiculopatia lombar, causada por hérnia de disco, relacionando os achados da semiologia clínica, tomografia axial computadorizada e eletroneuromiografia, entre si. A semiologia clínica estava alterada em 100,0% dos pacientes, a tomografia axial computadorizada em 90,7% e a eletroneuromiografia em 88,7%. A correlação entre os três exames não mostrou prevalência entre nenhuma associação. Os autores enfatizam a importância da semiologia clínica, tomografia axial computadorizada e eletroneuromiografia para maior exatidão diagnóstica das radiculopatias lombares por hérnia de disco.

  4. Contamination of basaltic lava by seawater: Evidence found in a lava pillar from Axial Seamount, Juan de Fuca Ridge

    Science.gov (United States)

    Schiffman, Peter; Zierenberg, Robert; Chadwick, William W.; Clague, David A.; Lowenstern, Jacob

    2010-04-01

    A lava pillar formed during the 1998 eruption at Axial Seamount exhibits compositional and textural evidence for contamination by seawater under magmatic conditions. Glass immediately adjacent to anastomosing microfractures within 1 cm of the inner pillar wall is oxidized and significantly enriched in Na and Cl and depleted in Fe and K with respect to that in glassy selvages from the unaffected outer pillar wall. The affected glass contains up to 1 wt % Cl and is enriched by ˜2 wt % Na2O relative to unaffected glass, consistent with a nearly 1:1 (molar) incorporation of NaCl. Glass bordering the Cl-enriched glass in the inner pillar wall is depleted in Na but enriched in K. The presence of tiny (<10 μm) grains of Cu-Fe sulfides and Fe sulfides as well as elemental Ni, Ag, and Au in the Na-depleted, K-enriched glass of the inner pillar wall implies significant reduction of this glass, presumably by hydrogen generated during seawater contamination and oxidation of lava adjacent to microfractures. We interpret the compositional anomalies we see in the glass of the interior pillar wall as caused by rapid incorporation of seawater into the still-molten lava during pillar growth, probably on the time scale of seconds to minutes. Only one of seven examined lava pillars shows this effect, and we interpret that seawater has to be trapped in contact with molten lava (inside the lava pillar, in this case) to produce the effects we see. Thus, under the right conditions, seawater contamination of lavas during submarine eruptions is one means by which the oceanic crust can sequester Cl during its global flux cycle. However, since very few recent lava flows have been examined in similar detail, the global significance of this process in effecting Earth's Cl budget remains uncertain.

  5. Axial myopathy

    DEFF Research Database (Denmark)

    Witting, Nanna; Andersen, Linda K; Vissing, John

    2016-01-01

    musculature involvement in the majority of myopathies in which paraspinal musculature was examined. Even in diseases named after a certain pattern of non-axial muscle affection, such as facioscapulohumeral and limb girdle muscular dystrophies, affection of the axial musculature was often severe and early...

  6. Computed tomography evidence of dental restoration as aetiological factor for maxillary sinusitis.

    Science.gov (United States)

    Connor, S E; Chavda, S V; Pahor, A L

    2000-07-01

    Maxillary sinusitis due to dental causes is usually secondary to periodontal disease or periapical infection and is commonly associated with mucosal thickening of the floor of the maxillary antrum. Computed tomography (CT) is currently the modality of choice for evaluating the extent of disease and any predisposing factors in patients with symptoms of chronic maxillary sinusitis, but it is unable to diagnose dental disease reliably. The presence of restorative dentistry is, however, easily seen at CT and is associated with both periapical and periodontal disease. We aimed to determine whether its presence at CT may predispose to maxillary sinusitis, and in particular to focal mucosal thickening of the sinus floor characteristic of dental origin. Three hundred and thirty maxillary sinus CT images in 165 patients were reviewed for the presence of restorative dentistry in the adjacent teeth, focal maxillary sinus floor mucosal thickening, any maxillary sinus disease (including complete opacification, air fluid levels, diffuse mucosal thickening, focal mucosal thickening) and evidence of a rhinogenic aetiology (osteomeatal complex pathology, mucosal thickening in other sinuses). One hundred and ninety two sinuses adjacent to restorative dentistry and 178 sinuses not adjacent to restorative dentistry were analysed. Focal floor thickening both with, and without, evidence of a rhinogenic aetiology, was significantly more common adjacent to restorative dentistry. Maxillary sinus disease overall was no more common adjacent to restorative dentistry. This work demonstrated that the presence of restorative dentistry predisposes to focal mucosal thickening in the floor of the maxillary sinus and its presence should prompt clinical and radiographical assessment to exclude dental disease as a source of chronic maxillary sinusitis.

  7. Prognosis of the computerized tomography in the severe head injury. Valor pronostico de la tomografia axial computada (TC) en los traumatismos craneoencefalicos severos

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Nieto, J.J.; Lorenzo Dominguez, M.T.; Martin Sanchez, M.J.; Sanchez Gonzalez, E.

    1991-01-01

    A prospective study is made with sixty five people affected of severe head injury, that is to say, with eight or less points in the Glasgow Coma Scale (GCS), when they get to the hospital. They are studied by computerized tomography at admission, and three and seven days after arrival. In this way, we appraise the type of the lesion, its intensity and the possible prognosis, considering in the last case three features: a) ventricular collapse; b) the mean line structure s shift; and c) effects on perimesencephalic cistern. The findings were parametized and we were able to introduce into the computer program relationships between these findings and the end results. These last ones were appraised through the Glasgow Outcome Scale (GOS). We could show that certain findings in computerized tomography scans have an unavoidable prognosis while as others have a more favorable prognosis. (Author)

  8. Ultrastructure and potential sub-seafloor evidence of bacteriogenic iron oxides from Axial Volcano, Juan de Fuca Ridge, north-east Pacific Ocean.

    Science.gov (United States)

    Kennedy, C B; Scott, S D; Ferris, F G

    2003-03-01

    Iron oxides from the caldera of Axial Volcano, a site of hydrothermal vent activity along the Juan de Fuca Ridge, were found to consist predominantly of microbial structures in hydrated whole mounts examined using an environmental scanning electron microscope. Novel observations were made of the iron oxides revealing the spatial relationships of the bacteria within to be more consistent with microbial mats than mineral precipitates. The bacterial structures are attributed to the sheaths of Leptothrix ochracea, the stalks of Gallionella ferruginea, and the filaments of a novel iron oxidizing PV-1 strain, based on the distinctive morphological characteristics of these three bacteria. Energy dispersive X-ray spectroscopy revealed the presence and distribution of Fe, Si, and Cl on the bacterial sheaths, stalks and filaments. The iron oxides were identified by X-ray diffraction to be two-line ferrihydrite, a poorly ordered iron oxyhydroxide. Adsorption of Si in particular to two-line ferrihydrite likely contributes to its stability on the seafloor, and might also be a preservation mechanism creating microfossils of the bacterial structures encrusted with ferrihydrite. Presumptive evidence of the sub-seafloor presence of L. ochracea, G. ferruginea and PV-1 at Axial Volcano was obtained from the presence of these bacteria on a trap that had been placed within an active vent, and also in a vent fluid sample. If indeed these bacteria are present in the sub-seafloor, it may be an indication that the surface expression of iron oxide deposits at Axial Volcano is minimal in comparison to what exists beneath the seafloor.

  9. Characterization of electrical properties in axial Si-Ge nanowire heterojunctions using off-axis electron holography and atom-probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gan, Zhaofeng [Department of Physics, Arizona State University, Tempe, Arizona 85287, USA; Perea, Daniel E. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Yoo, Jinkyoung [Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; He, Yang [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pennsylvania 15261, USA; Colby, Robert J. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Barker, Josh E. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Gu, Meng [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Mao, Scott X. [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pennsylvania 15261, USA; Wang, Chongmin [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Picraux, S. T. [Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Smith, David J. [Department of Physics, Arizona State University, Tempe, Arizona 85287, USA; McCartney, Martha R. [Department of Physics, Arizona State University, Tempe, Arizona 85287, USA

    2016-09-13

    Doped Si-Ge nanowire (NW) heterojunctions were grown using the vapor-liquid-solid method with AuGa and Au catalyst particles. Transmission electron microscopy and off-axis electron holography (EH) were used to characterize the nanostructure and to measure the electrostatic potential profile across the junction resulting from electrically active dopants, while atom-probe tomography (APT) was used to determine the Si, Ge and total (active and inactive) dopant concentration profiles. A comparison of the measured potential profile with simulations indicated that Ga dopants unintentionally introduced during AuGa catalyst growth were electronically inactive despite APT results that showed considerable amounts of Ga in the Si region. 10% P in Ge and 100% B in Si were estimated to be activated, which was corroborated by in situ electron-holography biasing experiments. This combination of EH, APT, in situ biasing and simulations allows a better knowledge and understanding of the electrically active dopant distributions in NWs.

  10. Origin of the Changbai intraplate volcanism in Northeast China:Evidence from seismic tomography

    Institute of Scientific and Technical Information of China (English)

    ZHAO Dapeng; LEI Jianshe; TANG Rongyu

    2004-01-01

    Seismic images of the mantle beneath the active Changbai intraplate volcano in Northeast China determined by teleseismic travel time tomography are presented. The data are measured at a new seismic network consisting of 19 portable stations and 3 permanent stations. The results show a columnar low-velocity (-3 %) anomaly extending to 400 km depth under the Changbai volcano. High velocity anomalies are visible in the mantle transition zone, and deep earthquakes occur at depths of 500-600 km under the region,suggesting that the subducting Pacific slab is stagnant in the transition zone, as imaged clearly also by global tomography.These results suggest that the Changbai intraplate volcano is not a hotspot like Hawaii but a kind of back-arc volcano related to the upwelling of hot asthenospheric materials associated with the deep subduction and stagnancy of the Pacific slab under northeast Asia.

  11. Evidence for a coherent southeastern edge of the Farallon slab window from USArray tomography models

    Science.gov (United States)

    Panessa, Alexander

    Before the San Andreas Fault developed, subduction of the ancient Farallon plate dominated North America's west coast. As the Pacific-Farallon ridge reached the continent and Farallon subduction became restricted to separate regions, an area with no slab formed under southwestern North America. The northern boundary of this "slab window" is well-defined in recent high-resolution tomography models derived from USArray data, but the geometry of the southeastern edge of the slab window has received less attention. I will show that this eastern edge exists as a coherent boundary separating the subducted Cocos plate from the slab window. I adapt stage pole data for the Cocos plate into a single surface slab model designed to track the motion of the plate through time. This model of the Cocos plate geometry is consistent with recently published tomography models derived from combinations of USArray and global seismic data. The tomography results suggest the subducted slab remains intact along the southeastern edge of the Farallon slab window.

  12. Improper hydrogen bonded cyclohexane C-Hax···Yax contacts: theoretical predictions and experimental evidence from 1H NMR spectroscopy of suitable axial cyclohexane models.

    Science.gov (United States)

    Kolocouris, Antonios; Zervos, Nikolaos; De Proft, Frank; Koch, Andreas

    2011-06-03

    C-H(ax)···Y(ax) contacts are a textbook prototype of steric hindrance in organic chemistry. The nature of these contacts is investigated in this work. MP2/6-31+G(d,p) calculations predicted the presence of improper hydrogen bonded C-H(ax)···Y(ax) contacts of different strength in substituted cyclohexane rings. To support the theoretical predictions with experimental evidence, several synthetic 2-substituted adamantane analogues (1-24) with suitable improper H-bonded C-H(ax)···Y(ax) contacts of different strength were used as models of a substituted cyclohexane ring. The (1)H NMR signal separation, Δδ(γ-CH(2)), within the cyclohexane ring γ-CH(2)s is raised when the MP2/6-31+G(d,p) calculated parameters, reflecting the strength of the H-bonded C-H(ax)···Y(ax) contact, are increased. In molecules with enhanced improper H-bonded contacts C-H(ax)···Y(ax), like those having sterically crowded contacts (Y(ax) = t-Bu) or contacts including considerable electrostatic attractions (Y(ax) = O-C or O═C) the calculated DFT steric energies of the γ-axial hydrogens are considerably reduced reflecting their electron cloud compression. The results suggest that the proton H(ax) electron cloud compression, caused by the C-H(ax)···Y(ax) contacts, and the resulting increase in Δδ(γ-CH(2)) value can be effected not just from van der Waals spheres compression, but more generally from electrostatic attraction forces and van der Waals repulsion, both of which are improper H-bonding components.

  13. Light axial vector mesons

    CERN Document Server

    Chen, Kan; Liu, Xiang; Matsuki, Takayuki

    2015-01-01

    Inspired by the abundant experimental observation of axial vector states, we study whether the observed axial vector states can be categorized into the conventional axial vector meson family. In this paper we carry out analysis based on the mass spectra and two-body Okubo-Zweig-Iizuka-allowed decays. Besides testing the possible axial vector meson assignments, we also predict abundant information for their decays and the properties of some missing axial vector mesons, which are valuable to further experimental exploration of the observed and predicted axial vector mesons.

  14. Cryoelectron tomography of HIV-1 envelope spikes: further evidence for tripod-like legs.

    Directory of Open Access Journals (Sweden)

    Ping Zhu

    2008-11-01

    Full Text Available A detailed understanding of the morphology of the HIV-1 envelope (Env spike is key to understanding viral pathogenesis and for informed vaccine design. We have previously presented a cryoelectron microscopic tomogram (cryoET of the Env spikes on SIV virions. Several structural features were noted in the gp120 head and gp41 stalk regions. Perhaps most notable was the presence of three splayed legs projecting obliquely from the base of the spike head toward the viral membrane. Subsequently, a second 3D image of SIV spikes, also obtained by cryoET, was published by another group which featured a compact vertical stalk. We now report the cryoET analysis of HIV-1 virion-associated Env spikes using enhanced analytical cryoET procedures. More than 2,000 Env spike volumes were initially selected, aligned, and sorted into structural classes using algorithms that compensate for the "missing wedge" and do not impose any symmetry. The results show varying morphologies between structural classes: some classes showed trimers in the head domains; nearly all showed two or three legs, though unambiguous three-fold symmetry was not observed either in the heads or the legs. Subsequently, clearer evidence of trimeric head domains and three splayed legs emerged when head and leg volumes were independently aligned and classified. These data show that HIV-1, like SIV, also displays the tripod-like leg configuration, and, unexpectedly, shows considerable gp41 leg flexibility/heteromorphology. The tripod-like model for gp41 is consistent with, and helps explain, many of the unique biophysical and immunological features of this region.

  15. Grapevine petioles are more sensitive to drought induced embolism than stems: evidence from in vivo MRI and microcomputed tomography observations of hydraulic vulnerability segmentation.

    Science.gov (United States)

    Hochberg, Uri; Albuquerque, Caetano; Rachmilevitch, Shimon; Cochard, Herve; David-Schwartz, Rakefet; Brodersen, Craig R; McElrone, Andrew; Windt, Carel W

    2016-09-01

    The 'hydraulic vulnerability segmentation' hypothesis predicts that expendable distal organs are more susceptible to water stress-induced embolism than the main stem of the plant. In the current work, we present the first in vivo visualization of this phenomenon. In two separate experiments, using magnetic resonance imaging or synchrotron-based microcomputed tomography, grapevines (Vitis vinifera) were dehydrated while simultaneously scanning the main stems and petioles for the occurrence of emboli at different xylem pressures (Ψx ). Magnetic resonance imaging revealed that 50% of the conductive xylem area of the petioles was embolized at a Ψx of -1.54 MPa, whereas the stems did not reach similar losses until -1.9 MPa. Microcomputed tomography confirmed these findings, showing that approximately half the vessels in the petioles were embolized at a Ψx of -1.6 MPa, whereas only few were embolized in the stems. Petioles were shown to be more resistant to water stress-induced embolism than previously measured with invasive hydraulic methods. The results provide the first direct evidence for the hydraulic vulnerability segmentation hypothesis and highlight its importance in grapevine responses to severe water stress. Additionally, these data suggest that air entry through the petiole into the stem is unlikely in grapevines during drought.

  16. Modular functional organisation of the axial locomotor system in salamanders.

    Science.gov (United States)

    Cabelguen, Jean-Marie; Charrier, Vanessa; Mathou, Alexia

    2014-02-01

    Most investigations on tetrapod locomotion have been concerned with limb movements. However, there is compelling evidence that the axial musculoskeletal system contributes to important functions during locomotion. Adult salamanders offer a remarkable opportunity to examine these functions because these amphibians use axial undulations to propel themselves in both aquatic and terrestrial environments. In this article, we review the currently available biological data on axial functions during various locomotor modes in salamanders. We also present data showing the modular organisation of the neural networks that generate axial synergies during locomotion. The functional implication of this modular organisation is discussed.

  17. Altered Axial Skeletal Development

    Science.gov (United States)

    The axial skeleton is routinely examined in standard developmental toxicity bioassays and has proven to be sensitive to a wide variety of chemical agents. Dysmorphogenesis in the skull, vertebral column and ribs has been described in both human populations and in laboratory anima...

  18. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  19. Positron Emission Tomography (PET) in the oncologic clinical practice; Tomografia por Emision de Positrones (PET) en la practica clinica oncologica

    Energy Technology Data Exchange (ETDEWEB)

    Serna M, J.A.; Luviano, C.; Martinez V, D. [Hospital Angeles del Pedregal Mexico DF (Mexico); Maldonado S, A. [Centro PET Complutense, Madrid (Spain)

    2005-07-01

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  20. Influence of pore size distributions on decomposition of maize leaf residue: evidence from X-ray computed micro-tomography

    Science.gov (United States)

    Negassa, Wakene; Guber, Andrey; Kravchenko, Alexandra; Rivers, Mark

    2014-05-01

    Soil's potential to sequester carbon (C) depends not only on quality and quantity of organic inputs to soil but also on the residence time of the applied organic inputs within the soil. Soil pore structure is one of the main factors that influence residence time of soil organic matter by controlling gas exchange, soil moisture and microbial activities, thereby soil C sequestration capacity. Previous attempts to investigate the fate of organic inputs added to soil did not allow examining their decomposition in situ; the drawback that can now be remediated by application of X-ray computed micro-tomography (µ-CT). The non-destructive and non-invasive nature of µ-CT gives an opportunity to investigate the effect of soil pore size distributions on decomposition of plant residues at a new quantitative level. The objective of this study is to examine the influence of pore size distributions on the decomposition of plant residue added to soil. Samples with contrasting pore size distributions were created using aggregate fractions of five different sizes (soil samples. Dried pieces of maize leaves 2.5 mg in size (equivalent to 1.71 mg C g-1 soil) were added to half of the studied samples. Samples with and without maize leaves were incubated for 120 days. CO2 emission from the samples was measured at regular time intervals. In order to ensure that the observed differences are due to differences in pore structure and not due to differences in inherent properties of the studied aggregate fractions, we repeated the whole experiment using soil from the same aggregate size fractions but ground to soil size fractions of intact aggregates, and 40-50% in ground samples, respectively. The results of the incubation experiment demonstrated that, while greater C mineralization was observed in samples of all size fractions amended with leaf, the effect of leaf presence was most pronounced in the smaller aggregate fractions (0.05-0.1 mm and 0.05 mm) of intact aggregates. The results of

  1. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  2. Evidence of different thermoregulatory mechanisms between two sympatric Scarabaeus species using infrared thermography and micro-computer tomography.

    Directory of Open Access Journals (Sweden)

    José R Verdú

    Full Text Available In endotherms insects, the thermoregulatory mechanisms modulate heat transfer from the thorax to the abdomen to avoid overheating or cooling in order to obtain a prolonged flight performance. Scarabaeus sacer and S. cicatricosus, two sympatric species with the same habitat and food preferences, showed daily temporal segregation with S. cicatricosus being more active during warmer hours of the day in opposition to S. sacer who avoid it. In the case of S. sacer, their endothermy pattern suggested an adaptive capacity for thorax heat retention. In S. cicatricosus, an active 'heat exchanger' mechanism was suggested. However, no empirical evidence had been documented until now. Thermographic sequences recorded during flight performance showed evidence of the existence of both thermoregulatory mechanisms. In S. sacer, infrared sequences showed a possible heat insulator (passive thermal window, which prevents heat transfer from meso- and metathorax to the abdomen during flight. In S. cicatricosus, infrared sequences revealed clear and effective heat flow between the thorax and abdomen (abdominal heat transfer that should be considered the main mechanism of thermoregulation. This was related to a subsequent increase in abdominal pumping (as a cooling mechanism during flight. Computer microtomography scanning, anatomical dissections and internal air volume measurements showed two possible heat retention mechanisms for S. sacer; the abdominal air sacs and the development of the internal abdominal sternites that could explain the thermoregulation between thorax and abdomen. Our results suggest that interspecific interactions between sympatric species are regulated by very different mechanisms. These mechanisms create unique thermal niches for the different species, thereby preventing competition and modulating spatio-temporal distribution and the composition of dung beetle assemblages.

  3. Photoelastic tomography as hybrid mechanics

    OpenAIRE

    Errapart A.; Ainola L.; Aben H.

    2010-01-01

    Photoelastic tomography is a non-destructive method of 3D stress analysis. It permits determination of normal stress distribution in an arbitrary section of a 3D test object. In case of axial symmetry also the shear stress distribution can be determined directly from the measurement data. To determine also the other stress components one can use equations of the theory of elasticity. Such a combined application of experimental measurements and numerical handling of the equations of the ...

  4. In vivo evidence for greater amphetamine-induced dopamine release in pathological gambling: a positron emission tomography study with [(11)C]-(+)-PHNO.

    Science.gov (United States)

    Boileau, I; Payer, D; Chugani, B; Lobo, D S S; Houle, S; Wilson, A A; Warsh, J; Kish, S J; Zack, M

    2014-12-01

    Drug addiction has been associated with deficits in mesostriatal dopamine (DA) function, but whether this state extends to behavioral addictions such as pathological gambling (PG) is unclear. Here we used positron emission tomography and the D3 receptor-preferring radioligand [(11)C]-(+)-PHNO during a dual-scan protocol to investigate DA release in response to oral amphetamine in pathological gamblers (n=12) and healthy controls (n=11). In contrast with human neuroimaging findings in drug addiction, we report the first evidence that PG is associated with greater DA release in dorsal striatum (54-63% greater [(11)C]-(+)-PHNO displacement) than controls. Importantly, dopaminergic response to amphetamine in gamblers was positively predicted by D3 receptor levels (measured in substantia nigra), and related to gambling severity, allowing for construction of a mechanistic model that could help explain DA contributions to PG. Our results are consistent with a hyperdopaminergic state in PG, and support the hypothesis that dopaminergic sensitization involving D3-related mechanisms might contribute to the pathophysiology of behavioral addictions.

  5. Macular thickness measured by stratus optical coherence tomography in patients with diabetes type 2 and mild nonproliferative retinopathy without clinical evidence of macular edema.

    Science.gov (United States)

    Pires, Isabel; Santos, Ana Rita; Nunes, Sandrina; Lobo, Conceição

    2013-01-01

    To evaluate macular thickness in eyes with mild nonproliferative diabetic retinopathy (NPDR), patients with diabetes type 2, NPDR level 20 or 35, and without evidence of clinical macular edema underwent best-corrected visual acuity assessment, color fundus photography and Stratus optical coherence tomography. Mean center point thickness (CPT) and mean central subfield (CSF) thickness were compared with those of a healthy control population. 410 eyes/patients aged 61.2 ± 8.3 years, and with glycosylated hemoglobin of 7.9 ± 1.5% were included. Mean CPT and CSF were 186.6 ± 28.4 and 215.2 ± 25 µm, respectively, significantly increased compared to healthy subjects (p < 0.001). CSF thickness was abnormally increased in 17.6% of the patients, with values within the normal range in 79.5%, and abnormally decreased in 2.9%. CPT and CSF thickness were significantly thicker in men. No systemic factors showed a significant association. A significant increase in the macular thickness was found in eyes/patients with mild NPDR without clinical macular edema; however, only 17.6% of the eyes/patients had abnormally increased values and less than 3% abnormally decreased values.

  6. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  7. Fe-implanted 6H-SiC: Direct evidence of Fe{sub 3}Si nanoparticles observed by atom probe tomography and {sup 57}Fe Mössbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Diallo, M. L.; Fnidiki, A., E-mail: abdeslem.fnidiki@univ-rouen.fr; Lardé, R.; Cuvilly, F.; Blum, I. [Groupe de Physique des Matériaux, Université et INSA de Rouen - UMR CNRS 6634 - Normandie Université. F-76801 Saint Etienne du Rouvray (France); Lechevallier, L. [Groupe de Physique des Matériaux, Université et INSA de Rouen - UMR CNRS 6634 - Normandie Université. F-76801 Saint Etienne du Rouvray (France); Département de GEII, Université de Cergy-Pontoise, rue d' Eragny, Neuville sur Oise, 95031 Cergy-Pontoise (France); Debelle, A.; Thomé, L. [Centre de Spectrométrie Nucléaire et de Spectrométrie de Masse (CSNSM), CNRS-IN2P3-Univ. Paris-Sud 11, Bât. 108, 91405 Orsay (France); Viret, M. [Service de Physique de l' Etat Condensé (DSM/IRAMIS/SPEC), UMR 3680 CNRS, Bât. 772, Orme des Merisiers, CEA Saclay 91191 Gif sur Yvette (France); Marteau, M.; Eyidi, D.; Declémy, A. [Institut PPRIME, UPR 3346 CNRS, Université de Poitiers, ENSMA, SP2MI, téléport 2, 11 Bvd M. et P. Curie 86962 Futuroscope, Chasseneuil (France)

    2015-05-14

    In order to understand ferromagnetic ordering in SiC-based diluted magnetic semiconductors, Fe-implanted 6H-SiC subsequently annealed was studied by Atom Probe Tomography, {sup 57}Fe Mössbauer spectroscopy and SQUID magnetometry. Thanks to its 3D imaging capabilities at the atomic scale, Atom Probe Tomography appears as the most suitable technique to investigate the Fe distribution in the 6H-SiC host semiconductor and to evidence secondary phases. This study definitely evidences the formation of Fe{sub 3}Si nano-sized clusters after annealing. These clusters are unambiguously responsible for the main part of the magnetic properties observed in the annealed samples.

  8. [Evidence-based recommendations on diagnostics and therapy of axial spondyloarthritis : S3 guidelines of the German Society of Rheumatology (DGRh) in cooperation with the Association of the Scientific Medical Societies in Germany (AWMF)].

    Science.gov (United States)

    Kiltz, U; Rudwaleit, M; Sieper, J; Braun, J

    2017-03-01

    The clinical course of axial spondyloarthritis (SpA) is variable and characterized by chronic back pain and extraspinal manifestations, such as asymmetrical arthritis, dactylitis and enthesitis. Extra-articular manifestations in the eyes (anterior uveitis), skin (psoriasis) and intestines (chronic inflammatory bowel disease) are also frequent manifestations in patients with SpA. Due to the heterogeneity of disease manifestations and the partial concentration on structural alterations in the sacroiliac joints visible in X‑ray images, the diagnosis is often delayed for many years. An important step in the direction of improved early recognition of axial SpA was establishment of the Assessment of SpondyloArthritis International Society (ASAS) classification criteria published in 2009, which focused on the initally deep-seated back pain and chronicity in relatively young patients as well as the importance of magnetic resonance imaging and HLA B 27 determination in the early stages of the disease. In order to achieve the foundations for an effective and timely therapy of affected patients, in 2014 on the initiative of the German Society of Rheumatology, S3 guidelines on axial SpA including Bechterew's disease and early forms were formulated in cooperation with other specialist societies. This article gives an overview of the contents of the S3 guidelines on axial SpA.

  9. "Slab graveyards" beneath axial rift of the Mid-Atlantic Ridge?: Evidence from SHRIMP-II dating of zircon in gabbroids from the Markov Deep, 6oN

    Science.gov (United States)

    Sharkov, E.; Bortnikov, N.; Zinger, T.; Lepekhina3, E.; Sergeev, S.

    2009-04-01

    Unusually ancient (ranging from ~100 to 300 and even 2230 Ma [5, 6, etc.) and young (~1.2-2 Ma [1] zircons were discovered in the axial Mid-Atlantic Ridge (MAR) zone using U-Pb dating. At first glance, finds of ancient zircons are inconsistent with the general accepted plate tectonics model which suggests the formation of new oceanic crust in the spreading zone of the World Ocean. However, they can be explained by features of the oceanic mantle structure. We have dated 150 grains of zircon by U-Pb SIMS SHRIMP technique, which identified both ancient and young zircons in the same samples of MAR gabbroids from Sierra Leone testing area, Markov Deep, 6oN, dredged during Cruise 10 of R/V "Akademik Ioffe" (2001-2002) and Cruise 22 of R/V "Professor Logachev" (2003) [2]. Zircons were separated from gabbroids in the Markov Deep from depths 3600-3240 and 3900-3600 m. All complexes of the oceanic lithosphere occur on it's slopes: mantle residual ultramafites (harzburgites, lherzolites, and dunites), diverse gabbroids, granodiorites, plagiogranites, dolerites and basalts, including fresh pillow lavas (with chilled glassy margins), and deformed and hydrothermally altered rocks with sulfide mineralization. Studied samples are represented by cataclased and altered leucogabbronorites and one sample of fresh non-cataclased troctolite. Based on SHRIMP U-Pb dating, zircons can be subdivided into two groups: "young" zircon (less than ~2.3 Ma) and "old" zircon (older than ~87 Ma). The young zircon often form subhedral crystals with thin oscillatory zoning and a sectorial structure. It has low U and Th contents (up to 100 μg/g) and extremely low radiogenic lead. Its 238U/206Pb age varied from 0.76 ± 0.04 Ma to 2.28 ± 0.18 Ma. Zircons from nearby plagiogranites define an intermediate age of ~1.2-1.4 Ma [1]. The magmatic nature of young zircon suggests that its age defines the crystallization age of the host magmatic rocks. Ancient zircons define U/Pb ages between the Paleozoic and

  10. Build Axial Gradient Field by Using Axial Magnetized Permanent Rings

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Axial magnetic field produced by an axial magnetized permanent ring was studied. For two permanent rings, if they are magnetized in the same directions, a nearly uniform axial field can be produced. If they are magnetized in opposite direction,an axial gradient magnetic field can be generated, with the field range changing from -B0 to B0. A permanent magnet with a high axial gradient field was fabricated, the measured results agree with the PANDIRA calculation very well. For wider usage,it is desirable for the field gradient to be changed. Some methods to produce the variable gradient field are presented. These kinds of axial gradient magnetic field can also be used as a beam focusing for linear accelerator if the periodic field can be produced along the beam trajectory. The axial magnetic field is something like a solenoid, large stray field will leak to the outside environment if no method is taken to control them. In this paper, one method is illustrated to shield off the outside leakage field.

  11. [Value of computerized axial tomography in cranio-cerebral injuries].

    Science.gov (United States)

    Vigouroux, R P; Baurand, C; Gomez, A; Legre, J; Regis, H; Debaene, A

    1976-01-01

    Since May 1975 was have been working in the field of C.A.T. and its application to study head injuries. We are presenting differents groups of patients studied by C.A.T. I. -- DATA OF C.A.T. IN THE CASES OF EMERGENCY AND IMMEDIATE POST-OPERATIVE FOLLOW-UP OF HEAD INJURIES A) EMERGENCY STATE As soon as the clinical state of an head injured patient was supposed to need an operation, C.A.T. was realized; so differents abnormal scanners may be observed: 1. epidural hematoma, 2. subdural hematoma, 3. intra-cerebral hematoma, 4. acute subdural hematoma or contusion. We must do some comments: -- The Emi-scanner is pre-eminent in showing the exact topography of the lesion : so, the flap is easier to realise. -- In most cases the Emi-scanner is easier to interpret than angiogram for example contusion and hematoma. We know the goods results in hematomas and the poors results in surgery of contusions. -- But the senior advantage of C.A.T. is to provide all the informations in the totality of skull content. Emi-scanner shows bilateral lesions, ipsilateral lesion. C.A.T. is pre-eminent in showing the presence of this two lesions, more accurately than senior methods of investigations, so C.A.T. permits emergency neurosurgical treatment. B) C.A.T. AND FOLLOW-UP Repeated studies at post-intervals can be accomplished without risk to the patient, thus making follow-up simpler and more effective to the neurosurgical attitude. C) POST-OPERATIVE CONTROL AND C.A.T. Post-operative complications are always hard to diagnosis. C.A.T. is painless, quick and safe, and easier to interpret than an angiogram. II -- SEQUELLAE STADE AND C.A.T. In this field certains advantages of C.A.T. are immediatly apparents. In most cases the C.A.T. is the best screening method. Patients carried out are: -- psychiatric troubles, -- post-traumatic epilepsy. The results are not reliable. There is no anatomical-clinical relation in most cases. Differents pictures are observed: -- asymetrical ventricle enlargment, -- global ventricule enlargment, -- partial cerebral atrophy. III -- DISCUSSION 1. We are at the beginning of our study. 2. This not always possible to obtain a C.A.T. in emergency for a head injury, especialy at night. 3. Patients investigated following head trauma are among the most difficult to study with C.A.T. These invididuals send to be restless and uncooperative. Numerous artefacts produced by patient motion may lead to erroneous negative or positive diagnosis, so general anesthesia is often helpful. It is hoped that as a more rapid scanners become available this problem will be obviated. The C.A.T. alone is not capable, to provide all the necessary date concerning head injury. The C.A.T. is, however, re-adjusting our total investigation (E.E.G., angiograms) philosophy and practice rather than replacing the standard neuroradiological technique, except, may be, with epidural hematoma.

  12. Dissipative Axial Inflation

    CERN Document Server

    Notari, Alessio

    2016-01-01

    We analyze in detail the background cosmological evolution of a scalar field coupled to a massless abelian gauge field through an axial term $\\frac{\\phi}{f_\\gamma} F \\tilde{F}$, such as in the case of an axion. Gauge fields in this case are known to experience tachyonic growth and therefore can backreact on the background as an effective dissipation into radiation energy density $\\rho_R$, which which can lead to inflation without the need of a flat potential. We analyze the system, for momenta $k$ smaller than the cutoff $f_\\gamma$, including numerically the backreaction. We consider the evolution from a given static initial condition and explicitly show that, if $f_\\gamma$ is smaller than the field excursion $\\phi_0$ by about a factor of at least ${\\cal O} (20)$, there is a friction effect which turns on before that the field can fall down and which can then lead to a very long stage of inflation with a generic potential. In addition we find superimposed oscillations, which would get imprinted on any kind of...

  13. Magnetic resonance imaging in diffuse idiopathic skeletal hyperostosis: similarities to axial spondyloarthritis.

    Science.gov (United States)

    Arad, Uri; Elkayam, Ori; Eshed, Iris

    2017-03-31

    Diffuse idiopathic skeletal hyperostosis (DISH) is a non-inflammatory condition that involves calcification and ossification of the spinal ligaments and entheses. While, characteristic magnetic resonance imaging (MRI) lesions of the spine in patients with axial spondyloarthritis, another enthesitis-related disease, have been described and defined, there is a paucity of information regarding the MRI findings in DISH. The aim of this study was to describe the MRI findings of patients with DISH. We collected computed tomography studies with findings characteristic of DISH and that also had corresponding and concurrent MRI studies of the spine. For each patient, sagittal T1-weighted and STIR MRI sequences were evaluated for anterior/posterior vertebral corners of bone marrow edema (BME) and fat deposition. In total, we assessed 156 vertebral units in 10 patients that had both radiographic evidence of DISH and available MRI studies of the spine. Lesions consistent with BME corners were detected in five patients, and in three of them, three separate sites were involved, a finding that is suggestive of axial spondyloarthritis (SpA) according to the ASAS/OMERACT consensus statement. Fat deposition corners were detected in eight patients and in seven of them, several sites were involved. Spinal MRI lesions that are characteristic of axial SpA were commonly observed in a cohort of patients with DISH. This bears relevance to cases with diagnostic uncertainty and may imply overlapping pathogenetic mechanisms for new bone formation in both SpA and DISH. Further study is indicated to better characterize the similarities and differences between the MRI lesions of DISH and SpA.

  14. Study of axial magnetic effect

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, Victor [IHEP, Protvino, Moscow region, 142284 Russia ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 (Russian Federation); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Chernodub, M. N. [CNRS, Laboratoire de Mathématiques et Physique Théorique, Université François-Rabelais Tours, Fédération Denis Poisson, Parc de Grandmont, 37200 Tours, France Department of Physics and Astronomy, University of Gent, Krijgslaan 281, S9, B-9000 Gent (Belgium); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Goy, V. A. [School of Natural Sciences, Far Eastern Federal University, Sukhanova street 8, Vladivostok, 690950 (Russian Federation); Landsteiner, K. [Instituto de Física Teórica UAM/CSIC, C/ Nicolás Cabrera 13-15, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Molochkov, A. V. [School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Ulybyshev, M. [ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 Russia Institute for Theoretical Problems of Microphysics, Moscow State University, Moscow, 119899 (Russian Federation)

    2016-01-22

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T{sup 2} behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction.

  15. Amplified Dispersive Optical Tomography

    CERN Document Server

    Goda, Keisuke; Jalali, Bahram

    2008-01-01

    Optical coherence tomography (OCT) has proven to be a powerful technique for studying tissue morphology in ophthalmology, cardiology, and endomicroscopy. Its performance is limited by the fundamental trade-off between the imaging sensitivity and acquisition speed -- a predicament common in virtually all imaging systems. In this paper, we circumvent this limit by using distributed Raman post-amplification of the reflection from the sample. We combine the amplification with simultaneously performed dispersive Fourier transformation, a process that maps the optical spectrum into an easily measured time-domain waveform. The Raman amplification enables measurement of weak signals which are otherwise buried in noise. It extends the depth range without sacrificing the acquisition speed or causing damage to the sample. As proof of concept, single-shot imaging with 15 dB improvement in sensitivity at an axial scan rate of 36.6 MHz is demonstrated.

  16. Dissipative axial inflation

    Science.gov (United States)

    Notari, Alessio; Tywoniuk, Konrad

    2016-12-01

    We analyze in detail the background cosmological evolution of a scalar field coupled to a massless abelian gauge field through an axial term phi/fγ F ~F, such as in the case of an axion. Gauge fields in this case are known to experience tachyonic growth and therefore can backreact on the background as an effective dissipation into radiation energy density ρR, which can lead to inflation without the need of a flat potential. We analyze the system, for momenta k smaller than the cutoff fγ, including the backreaction numerically. We consider the evolution from a given static initial condition and explicitly show that, if fγ is smaller than the field excursion phi0 by about a factor of at least Script O (20), there is a friction effect which turns on before the field can fall down and which can then lead to a very long stage of inflation with a generic potential. In addition we find superimposed oscillations, which would get imprinted on any kind of perturbations, scalars and tensors. Such oscillations have a period of 4-5 efolds and an amplitude which is typically less than a few percent and decreases linearly with fγ. We also stress that the curvature perturbation on uniform density slices should be sensitive to slow-roll parameters related to ρR rather than dot phi2/2 and we discuss the existence of friction terms acting on the perturbations, although we postpone a calculation of the power spectrum and of non-gaussianity to future work and we simply define and compute suitable slow roll parameters. Finally we stress that this scenario may be realized in the axion case, if the coupling 1/fγ to U(1) (photons) is much larger than the coupling 1/fG to non-abelian gauge fields (gluons), since the latter sets the range of the potential and therefore the maximal allowed phi0~ fG.

  17. Lens dosimetry during examination of the sella turcica: comparison between conventional tomography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Louis, O.; Bette, L.; Noseda, A.

    1986-01-01

    Lens irradiation measurements were performed with thermo-luminescent lithium fluoride dosimeters during tomographic examinations of the sella turcica, simulated on a phantom head. Lens dosimetry during linear or hypocycloidal conventional tomography was compared with that during computed tomography (CT). Results showed that CT involved much lower radiation exposure to the lens than did conventional tomography and that the major part of the irradiation delivered by CT was related to axial scanning. Therefore, the major finding was that lens irradiation during CT of the sella can be kept at a particularly low level (< 1 m Gy/8 sections) when only coronal scanning is performed.

  18. Influx of Different Galapagos Plume Components to the Galapagos Spreading Center: Evidence From Sr-Nd-Pb-Hf Isotope Variations in Axial Lavas Between 86W and 92.5W

    Science.gov (United States)

    Hauff, F.; Hanan, B.; Hoernle, K. A.; Kokfelt, T. F.; Christie, D.; Werner, R.

    2006-12-01

    We present new Sr-Nd-Pb-Hf isotope data of basaltic glasses from the GSC between 86W and 92.5W. In this part of the ridge the main structural inventory includes an overlapping spreading center (OSC) at 87.3W, a transform fault (TF) at 91W and a series of seamount chains intersecting the GSC West of the 91W TF. The systematic transition from an axial-valley and rift morphology at axial depths of 2450 m.b.s.l. in the 86W area to an axial-high morphology at progressively shallower depths of 1500 m.b.s.l in the 90.5W area together with gradational changes in major and trace element chemistry of the axial lavas is believed to reflect increasing mantle temperature and compositional changes related to the Galapagos plume [1]. Previous work from 83W to 105W revealed a broad symmetric gradational pattern at around 91W and lead to the conclusion that this region is the main point of plume influx on the GSC [2]. Based on published isotope data Christie et al. (2005) inferred the probable existence of two enrichment peaks immediately East and West of the 91TF. Indeed, along axis variations of our new Sr-Nd-Pb-Hf isotope data map two distinct peaks of enrichment at 92W and 90.5W, suggesting that mantle from the Galapagos hotspot enters the GSC melting zone on both sides of the 91W transform fault. Lavas from within the 91W TF are isotopically intermediate and show a distinct depletion in incompatible trace elements, which may reflect repeated melting at shallow depth of passively upwelling mantle in this unique extensional regime. At least three different components are required to generate the observed isotope correlations. When compared to the geographically distinct isotopic domains of the Galapagos islands; GSC lavas East of the 91W TF form tight correlations from the rim of the Central Galapagos domain through the Eastern Galapagos domain towards DMM. Most axial lavas and corresponding off axis seamounts West of the 91W TF have higher 87Sr/86Sr, 207Pb/204Pb, 208Pb/204Pb

  19. [Inflammatory spinal diseases: axial spondyloarthritis : Central importance of imaging].

    Science.gov (United States)

    Baraliakos, X; Fruth, M; Kiltz, U; Braun, J

    2017-03-01

    The diagnosis of axial spondyloarthritis (axSpA) includes classical ankylosing spondylitis (AS) as well as earlier stages and abortive courses of the disease, in which structural alterations have not yet occurred. These are classified as non-radiographic axSpA (nr-axSpa). Inflammatory changes in the entire axial skeleton are characteristic for axSpA and can be visualized by magnetic resonance imaging (MRI), while in most patients structural alterations, such as new bone formation with syndesmophytes and ankylosis develop in the later course of the disease. These bony alterations can best be visualized by conventional radiography and by computed tomography. Certain MRI sequences are nowadays considered as the standard method for depiction of inflammatory changes in axSpA. The introduction of MRI has led to a paradigm shift for this disease because the inflammatory lesions characteristic for the disease can be visualized at an early stage using appropriate MRI sequences.

  20. Relationship between chemical structure of soil organic matter and intra-aggregate pore structure: evidence from X-ray computed micro-tomography

    Science.gov (United States)

    Kravchenko, Alexandra; Grandy, Stuart A.

    2014-05-01

    Understanding chemical structure of soil organic matter (SOM) and factors that affect it are vital for gaining understanding of mechanisms of C sequestration by soil. Physical protection of C by adsorption to mineral particles and physical disconnection between C sources and microbial decomposers is now regarded as the key component of soil C sequestration. Both of the processes are greatly influenced by micro-scale structure and distribution of soil pores. However, because SOM chemical structure is typically studied in disturbed (ground and sieved) soil samples the experimental evidence of the relationships between soil pore structure and chemical structure of SOM are still scarce. Our study takes advantage of the X-ray computed micro-tomography (µ-CT) tools that enable non-destructive analysis of pore structure in intact soil samples. The objective of this study is to examine the relationship between SOM chemical structure and pore-characteristics in intact soil macro-aggregates from two contrasting long-term land uses. The two studied land use treatments are a conventionally tilled corn-soybean-wheat rotation treatment and a native succession vegetation treatment removed from agricultural use >20 years ago. The study is located in southwest Michigan, USA, on sandy-loam Typic Hapludalfs. For this study we used soil macro-aggregates 4-6 mm in size collected at 0-15 cm depth. The aggregate size was selected so as both to enable high resolution of µ-CT and to provide sufficient amount of soil for C measurements. X-ray µ-CT scanning was conducted at APS Argonne at a scanning resolution of 14 µm. Two scanned aggregates (1 per treatment) were used in this preliminary study. Each aggregate was cut into 7 "geo-referenced" sections. Analyses of pore characteristics in each section were conducted using 3DMA and ImageJ image analysis tools. SOM chemistry was analyzed using pyrolysis/gas chromatography-mass spectroscopy. Results demonstrated that the relationships

  1. Computed Tomography (CT) -- Sinuses

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the ... of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly ...

  2. [Inadvertent thoracic duct puncture during right axially central venous cannulation].

    Science.gov (United States)

    Kawashima, Shingo; Itagaki, Taiga; Adachi, Yushi; Ishii, Yasuhiro; Taniguchi, Midzuki; Doi, Matsuyuki; Sato, Shigehito

    2010-10-01

    A case of inadvertent thoracic duct puncture during right axially central venous cannulation is reported. The catheterization was performed under the real time ultrasound guidance technique and the coronal view image was continuously displayed. After confirming the feelings of venous puncture, clear yellow fluid was aspired into the connected syringe to the needle. Initially, an accidental thoracic puncture with subsequent pleural fluid aspiration was suspected;however, no finding of pleural effusion was observed with ultrasound imaging and computed tomography. Thus, an accidental thoracic duct puncture and the subsequent lymph fluid aspiration were suspected. Even in a right side approach for central venous catheterization, thoracic duct injury might ensure.

  3. Axial Current and Noether Charge

    CERN Document Server

    Mahato, Prasanta

    2012-01-01

    A decade ago, a Lagrangian density has been proposed by the author where only the local symmetries of the Lorentz subgroup of (A)ds group is retained. This formalism has been found to produce some results encompassing that of standard Einstein-Hilbert formalism. In the present article, the conserved axial vector matter currents, constructed in some earlier paper, have been found to be a result of Noether's theorem. PACS: 04.20.Fy, 04.20.Cv, 11.40.-q Keywords: Torsion, Axial Current, Noether's Theorem

  4. Relativistic RPA in axial symmetry

    CERN Document Server

    Arteaga, D Pena; 10.1103/PhysRevC.77.034317

    2009-01-01

    Covariant density functional theory, in the framework of self-consistent Relativistic Mean Field (RMF) and Relativistic Random Phase approximation (RPA), is for the first time applied to axially deformed nuclei. The fully self-consistent RMF+RRPA equations are posed for the case of axial symmetry and non-linear energy functionals, and solved with the help of a new parallel code. Formal properties of RPA theory are studied and special care is taken in order to validate the proper decoupling of spurious modes and their influence on the physical response. Sample applications to the magnetic and electric dipole transitions in $^{20}$Ne are presented and analyzed.

  5. Cortical and trabecular bone adaptation to incremental load magnitudes using the mouse tibial axial compression loading model.

    Science.gov (United States)

    Weatherholt, Alyssa M; Fuchs, Robyn K; Warden, Stuart J

    2013-01-01

    The mouse tibial axial compression loading model has recently been described to allow simultaneous exploration of cortical and trabecular bone adaptation within the same loaded element. However, the model frequently induces cortical woven bone formation and has produced inconsistent results with regards to trabecular bone adaptation. The aim of this study was to investigate bone adaptation to incremental load magnitudes using the mouse tibial axial compression loading model, with the ultimate goal of revealing a load that simultaneously induced lamellar cortical and trabecular bone adaptation. Adult (16 weeks old) female C57BL/6 mice were randomly divided into three load magnitude groups (5, 7 and 9N), and had their right tibia axially loaded using a continuous 2-Hz haversine waveform for 360 cycles/day, 3 days/week for 4 consecutive weeks. In vivo peripheral quantitative computed tomography was used to longitudinally assess midshaft tibia cortical bone adaptation, while ex vivo micro-computed tomography and histomorphometry were used to assess both midshaft tibia cortical and proximal tibia trabecular bone adaptation. A dose response to loading magnitude was observed within cortical bone, with increasing load magnitude inducing increasing levels of lamellar cortical bone adaptation within the upper two thirds of the tibial diaphysis. Greatest cortical bone adaptation was observed at the midshaft where there was a 42% increase in estimated mechanical properties (polar moment of inertia) in the highest (9N) load group. A dose response to load magnitude was not clearly evident within trabecular bone, with only the highest load (9N) being able to induce measureable adaptation (31% increase in trabecular bone volume fraction at the proximal tibia). The ultimate finding was that a load of 9N (engendering a tensile strain of 1833 με on medial surface of the midshaft tibia) was able to simultaneously induce measurable lamellar cortical and trabecular bone adaptation

  6. Doppler Tomography

    CERN Document Server

    Marsh, T R

    2000-01-01

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the a...

  7. Axial structure of the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Veronique Bernard; Latifa Elouadrhiri; Ulf-G Meissner

    2002-01-01

    We review the current status of experimental and theoretical understanding of the axial nucleon structure at low and moderate energies. Topics considered include (quasi)elastic (anti)neutrino-nucleon scattering, charged pion electroproduction off nucleons and ordinary as well as radiative muon capture on the proton.

  8. Thermophoresis of Axially Symmetric Bodies

    Science.gov (United States)

    2007-11-02

    Sweden Abstract. Thermophoresis of axially symmetric bodies is investigated to first order in the Knudsen-mimber, Kn. The study is made in the limit...derived. Asymptotic solutions are studied. INTRODUCTION Thermophoresis as a phenomenon has been known for a long time, and several authors have approached

  9. Experimental Demonstration of Spectral Intensity Optical Coherence Tomography

    CERN Document Server

    Ryczkowski, Piotr; Friberg, Ari T; Genty, Goëry

    2015-01-01

    We demonstrate experimentally quantum-inspired, spectral-domain intensity optical coherence tomography. We show that the technique allows for both axial resolution improvement and dispersion cancellation compared to conventional optical coherence tomography. The method does not involve scanning and it works with classical light sources and standard photodetectors. The measurements are in excellent agreement with the theoretical predictions. We also propose an approach that enables the elimination of potential artifacts arising from multiple interfaces.

  10. Cone Beam Computed Tomography - Know its Secrets

    OpenAIRE

    Kumar, Mohan; Shanavas, Muhammad; Sidappa, Ashwin; Kiran, Madhu

    2015-01-01

    Cone-beam computed tomography (CBCT) is an advanced imaging modality that has high clinical applications in the field of dentistry. CBCT proved to be a successful investigative modality that has been used for dental and maxillofacial imaging. Radiation exposure dose from CBCT is 10 times less than from conventional CT scans during maxillofacial exposure. Furthermore, CBCT is highly accurate and can provide a three-dimensional volumetric data in axial, sagittal and coronal planes. This article...

  11. Optimization of axial blowers. Optimierung von Axial-Ventilatoren

    Energy Technology Data Exchange (ETDEWEB)

    Bolte, W.

    1992-08-01

    For the optimum possible design of axial blowers, trials are evaluated in the article, which are based on the grid profile examined by N. Scholz. The computation for the pressure number and the primary degree of efficiency are shown as well as the evaluation of the effect of the Reynolds and mach number on the degree of efficiency and determination of the secondary losses. In a final example, the dimensions of a blower are computed from the data determined during the trials. (orig.).

  12. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  13. Axial Spondyloarthritis: An Evolving Concept

    Directory of Open Access Journals (Sweden)

    Nelly Ziadé

    2015-07-01

    Full Text Available Axial spondyloarthritis (AxSpA is the prototype of a family of inter-related yet heterogeneous diseases sharing common clinical and genetic manifestations: the spondyloarthritides (SpAs. The condition mainly affects the sacroiliac joints and axial skeleton, and has a clear classification scheme, wider epidemiological data, and distinct therapeutic guidelines when compared with other SpAs. However, the concept of AxSpA has not been immutable over time and has evolved tremendously on many levels over the past decades. This review identifies the evolution of the AxSpA concept at two levels. First, at the level of classification, the old classifications and rationales leading to the current Assessment of SpondyloArthritis international Society (ASAS classification are reviewed, and the advantages and drawbacks are discussed. Second, at the therapeutic level, current and future treatments are described and treatment strategies are discussed.

  14. [Axial spondyloarthritis and ankylosing spondylitis].

    Science.gov (United States)

    Nordström, Dan; Kauppi, Markku

    2010-01-01

    Current classification criteria for ankylosing spondylitis do not allow diagnosis before radiographic changes are visible in sacroiliacal joints. The the new axial spondyloarthropathy (SpA) criteria include axial SpA without radiographic changes as well as established ankylosing spondylitis, recognizing them as a continuum of the same disease. This is of major importance as the burden of early SpA is comparable to that of later stage disease. Diagnosis relies on inflammatory MRI findings which is the most significant change compared to earlier criteria. Emerging data on the efficacy of tumor necrosis factor (TNF) alpha blocking therapies already in early but also in established disease have given new promising alternatives for treatment of this often very cumbersome disease, that rarely responds to classic DMARDs.

  15. Golimumab for treatment of axial spondyloarthritis.

    Science.gov (United States)

    Rios Rodriguez, Valeria; Poddubnyy, Denis

    2016-02-01

    Axial spondyloarthritis comprises two forms: nonradiographic (nonradiographic axial spondyloarthritis) and radiographic (better known as ankylosing spondylitis), which are often considered as two stages of one disease. Historically, all currently available TNF-α inhibitors were first investigated in ankylosing spondylitis and later on in nonradiographic axial spondyloarthritis. This year, EMA has granted golimumab approval for the treatment of active nonradiographic axial spondyloarthritis based on the recently published data from the GO-AHEAD study. This article summarizes recent data on efficacy and safety of golimumab in the treatment of ankylosing spondylitis and nonradiographic axial spondyloarthritis.

  16. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    Clinical trials for the treatment of cystic fibrosis (CF) lung disease are important to test and optimize new therapeutic interventions. To evaluate the effect of these interventions, sensitive and accurate outcome measures are needed. The most commonly used endpoints are spirometric variables...... are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  17. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  18. Unexplained heterochromia. Intraocular foreign body demonstrated by computed tomography.

    Science.gov (United States)

    Barr, C C; Vine, A K; Martonyi, C L

    1984-01-01

    Standard radiographic techniques are often inadequate in demonstrating the presence and location of intraocular foreign bodies. Computerized axial tomography was used to confirm the presence of a metallic foreign body in a patient with heterochromia iridis and suspected ocular siderosis in whom no foreign material was found by conventional examination methods.

  19. Single photon emission computed tomography/computed tomography for malignant otitis externa: lesion not shown on planar image.

    Science.gov (United States)

    Chen, Yu-Hung; Hsieh, Hung-Jen

    2013-01-01

    Malignant otitis externa is a severe and rare infection of the external acoustic meatus. Triphasic bone and (67)Ga scintigraphies are used to initial detect and follow-up the response of therapy. With single photon emission computed tomography/computed tomography images, the diagnostic sensitivity is higher. We presented a case with malignant otitis externa with initial negative planar scintigraphic finding. The lesion was detected by photon emission computed tomography/computed tomography images. We concluded that the photon emission computed tomography/computed tomography should be performed routinely for patients with suspected malignant otitis externa, even without evidence of lesion on planar images.

  20. Atlanto-axial subluxation after pyogenic spondylitis of the atlanto-occipital joint.

    Science.gov (United States)

    Tsunoda, Kazuhiko; Iizuka, Haku; Sorimachi, Yasunori; Ara, Tsuyoshi; Nishinome, Masahiro; Takechi, Yasuhiko; Takagishi, Kenji

    2011-07-01

    This report presents a case of atlanto-axial subluxation after treatment of pyogenic spondylitis of the atlanto-occipital joint. A 60-year-old male had 1-month history of neck pain with fever. Magnetic resonance imaging showed inflammation around the odontoid process. Intravenous antibiotic therapy was administrated immediately. After 6 weeks, CRP had returned almost to normal. After 4 months, laboratory data was still normal, but the patient experienced increasing neck pain. Lateral cervical radiography in the neutral position showed instability between C1 and C2. Computed tomography showed a bony union of the atlanto-occipital joint and severe destruction of the atlanto-axial joint on the left side. Transarticular screw fixation for the atlanto-axial joint was performed. A lateral cervical radiograph in the neutral position after surgery showed a solid bony union. Neck pain improved following surgery. We speculate that spondylitis of the atlanto-occipital joint induced a loosening of the transverse ligament and articulation of the atlanto-axial joint. A bony fusion of the atlanto-occipital joint after antibiotic treatment resolved the pyogenic inflammation concentrated stress to the damaged atlanto-axial joint, resulting in further damage. The atlanto-axial instability was finally managed by the insertion of a transarticular screw.

  1. High-resolution seismic tomography of the 2015 Mw7.8 Gorkha earthquake, Nepal: Evidence for the crustal tearing of the Himalayan rift

    Science.gov (United States)

    Pei, Shunping; Liu, Hongbing; Bai, Ling; Liu, Yanbing; Sun, Quan

    2016-09-01

    The Mw7.8 Gorkha earthquake struck Nepal and ruptured the boundary between the Indian and Eurasian plates. We conducted 2-D Pg wave tomography to clarify the seismogenic structure and try to understand causal mechanisms for this large earthquake, using the aftershock data recorded by 15 broadband seismic stations located near the China-Nepal border. Our high-resolution results show that coseismic slip area of the main shock is consistent with the high P wave velocity anomaly, and the region of maximum slip has a larger area with higher velocity than the region of initial slip, possibly resulting in the dominant low-frequency radiation of energy observed after the dominant high-frequency radiation of energy in the source rupture process. The boundary between these regions of contrasting high and low seismic velocity anomalies suggests a potential crustal tearing at the southern end of the Tangra Yum Co Rift, possibly resulting from different thrust speeds in the Greater Himalaya.

  2. Neutron tomography

    Science.gov (United States)

    Crump, James C., III; Richards, Wade J.; Shields, Kevin C.

    1995-07-01

    The McClellan Nuclear Radiation Center's (MNRC) staff in conjunction with a Cooperative Research and Development Agreement (CRDA) with the U.C. Santa Barbara facility has developed a system that can be used for aircraft inspection of jet engine blades. The problem was to develop an inspection system that can detect very low concentrations of hydrogen (i.e., greater than 100 ppm) in metal matricies. Specifically in Titanium alloy jet engine blades. Entrapment and precipitation of hydrogen in metals is an undesirable phenomenon which occurs in many alloys of steel and titanium. In general, metals suffer a loss of mechanical properties after long exposures to hydrogen, especially at high temperatures and pressures, thereby becoming embrittled. Neutron radiography has been used as a nondestructive testing technique for many years. Neutrons, because of their unique interactions with materials, are especially useful in the detection of hydrogen. They have an extremely high interaction cross section for low atomic number nuclei (i.e., hydrogen). Thus hydrogen in a metal matrix can be visualized using neutrons. Traditional radiography is sensitive to the total attenuation integrated over the path of radiation through the material. Increased sensitivity and quantitative cross section resolution can be obtained using three-dimensional volumetric imaging techniques such as tomography. The solution used to solve the problem was to develop a neutron tomography system. The neutron source is the McClellan Nuclear Radiation Center's 1 MW TRIGA reactor. This paper describes the hardware used in the system as well as some of the preliminary results.

  3. More evidence for the red-shift dependence of colour from the Joint Light-curve Analysis supernova sample using red-shift tomography

    Science.gov (United States)

    Li, Miao; Li, Nan; Wang, Shuang; Zhou, Lanjun

    2016-08-01

    In this work, by applying the red-shift tomography method to the Joint Light-curve Analysis (JLA) supernova sample, we explore the possible red-shift dependence of the stretch luminosity α and the colour luminosity β. The basic idea is to divide the JLA sample into different red-shift bins, assuming that α and β are piecewise constants. Then, by constraining the ΛCDM model, we check the consistency of the cosmology-fitting results given by the supernova sample of each red-shift bin. We also adopt the same technique to explore the possible evolution of β in various subsamples of JLA. Using the full JLA data, we find that α is always consistent with a constant value. In contrast, at high red shift, β has a significant trend of decreasing, at ˜3.5σ confidence level (CL). Moreover, we find that the low-z subsample favours a constant β; in contrast, the Sloan Digital Sky Survey and Supernova Legacy Survey subsamples favour a decreasing β at 2σ and 3.3σ CL, respectively. Besides, by using a binned parametrization of β, we study the impact of the evolution of β on parameter estimation. We find that compared with a constant β, a varying β yields a larger best-fitting value of fractional matter density Ωm0, which slightly deviates from the best-fitting result given by other cosmological observations. However, for both the varying β and the constant β cases, the 1σ regions of Ωm0 are still consistent with the result given by other observations.

  4. Axial Vector $Z'$ and Anomaly Cancellation

    CERN Document Server

    Ismail, Ahmed; Tsao, Kuo-Hsing; Unwin, James

    2016-01-01

    Whilst the prospect of new $Z'$ gauge bosons with only axial couplings to the Standard Model (SM) fermions is widely discussed, examples of anomaly-free renormalisable models are lacking in the literature. We look to remedy this by constructing several motivated examples. Specifically, we consider axial vectors which couple universally to all SM fermions, as well as those which are generation-specific, leptophilic, and leptophobic. Anomaly cancellation typically requires the presence of new coloured and charged chiral fermions, and we argue that the masses of these new states must generally be comparable to that of the axial vector. Finally, an axial vector mediator could provide a portal between SM and hidden sector states, and we also consider the possibility that the axial vector couples to dark matter. If the dark matter relic density is set due to freeze-out via the axial vector, this strongly constrains the parameter space.

  5. Non-traumatic atlanto-axial subluxation: Grisel's syndrome. Two case reports.

    Science.gov (United States)

    Cekinmez, Melih; Tufan, Kadir; Sen, Orhan; Caner, Hakan

    2009-04-01

    Two 8-year-old boys presented with complaints of torticollis and pain on neck turning. Both patients had a history of throat infection. Radiography and computed tomography demonstrated atlanto-axial subluxation. The patients were treated under diagnoses of Grisel's syndrome, unilateral or bilateral subluxation of the atlas on the axis associated with infection in the head or neck. Both patients were treated conservatively with bed rest, muscle relaxants, non-steroid anti-inflammatory agents, and immobilization with a soft cervical collar and cervical halter traction. The torticollis had resolved and reduction of atlanto-axial subluxation was confirmed within 2 weeks in both patients. Early diagnosis of Grisel's syndrome with appropriate antibiotics and a cervical collar, with halter traction if necessary, can achieve good outcome. Surgical treatment for the reduction of atlanto-axial subluxation should be reserved for persistent or recurrent cases.

  6. Diabetes mellitus and the eye: axial length

    OpenAIRE

    Huntjens, B.; O’Donnell, C.

    2006-01-01

    Background and aims: The refractive error of the eye is dependent on its axial length. Refractive error is known to fluctuate significantly in poorly controlled diabetic patients. Recently it has been reported that human eyes fluctuate in axial length during the day. However, this change is not detectable in all subjects, suggesting physiological influences such as diet. The purpose of this study was to investigate fluctuations in axial length and blood glucose levels (BGLs) in diabetic patie...

  7. System Study for Axial Vane Engine Technology

    Science.gov (United States)

    Badley, Patrick R.; Smith, Michael R.; Gould, Cedric O.

    2008-01-01

    The purpose of this engine feasibility study was to determine the benefits that can be achieved by incorporating positive displacement axial vane compression and expansion stages into high bypass turbofan engines. These positive-displacement stages would replace some or all of the conventional compressor and turbine stages in the turbine engine, but not the fan. The study considered combustion occurring internal to an axial vane component (i.e., Diesel engine replacing the standard turbine engine combustor, burner, and turbine); and external continuous flow combustion with an axial vane compressor and an axial vane turbine replacing conventional compressor and turbine systems.

  8. Diffraction tomography with Fourier ptychography

    CERN Document Server

    Horstmeyer, Roarke

    2015-01-01

    This article presents a method to perform diffraction tomography in a standard microscope that includes an LED array for illumination. After acquiring a sequence of intensity-only images of a thick sample, a ptychography-based reconstruction algorithm solves for its unknown complex index of refraction across three dimensions. The experimental microscope demonstrates a spatial resolution of 0.39 $\\mu$m and an axial resolution of 3.7 $\\mu$m at the Nyquist-Shannon sampling limit (0.54 $\\mu$m and 5.0 $\\mu$m at the Sparrow limit, respectively), across a total imaging volume of 2.2 mm $\\times$ 2.2 mm $\\times$ 110 $\\mu$m. Unlike competing methods, the 3D tomograms presented in this article are continuous, quantitative, and formed without the need for interferometry or any moving parts. Wide field-of-view reconstructions of thick biological specimens demonstrate potential applications in pathology and developmental biology.

  9. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  10. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  11. Photoelastic tomography as hybrid mechanics

    Directory of Open Access Journals (Sweden)

    Errapart A.

    2010-06-01

    Full Text Available Photoelastic tomography is a non-destructive method of 3D stress analysis. It permits determination of normal stress distribution in an arbitrary section of a 3D test object. In case of axial symmetry also the shear stress distribution can be determined directly from the measurement data. To determine also the other stress components one can use equations of the theory of elasticity. Such a combined application of experimental measurements and numerical handling of the equations of the theory of elasticity is named hybrid mechanics. It is shown that if stresses are due to external loads, the hybrid mechanics algorithm is based on the equations of equilibrium and compatibility. In the case of the measurement of the residual stress in glass the compatibility equation can not be applied. In this case a new relationship of axisymmetric thermoelasticity, the generalized sum rule can be applied.

  12. Photoelastic tomography as hybrid mechanics

    Science.gov (United States)

    Aben, H.; Ainola, L.; Errapart, A.

    2010-06-01

    Photoelastic tomography is a non-destructive method of 3D stress analysis. It permits determination of normal stress distribution in an arbitrary section of a 3D test object. In case of axial symmetry also the shear stress distribution can be determined directly from the measurement data. To determine also the other stress components one can use equations of the theory of elasticity. Such a combined application of experimental measurements and numerical handling of the equations of the theory of elasticity is named hybrid mechanics. It is shown that if stresses are due to external loads, the hybrid mechanics algorithm is based on the equations of equilibrium and compatibility. In the case of the measurement of the residual stress in glass the compatibility equation can not be applied. In this case a new relationship of axisymmetric thermoelasticity, the generalized sum rule can be applied.

  13. The Emergence of Axial Parts

    Directory of Open Access Journals (Sweden)

    Peter Svenonius

    2007-01-01

    Full Text Available Many languages have specialized locative words or morphemes translating roughly into words like ‘front,’ ‘back,’ ‘top,’ ‘bottom,’ ‘side,’ and so on. Often, these words are used instead of more specialized adpositions to express spatial meanings corresponding to ‘behind,’ ‘above,’ and so on. I argue, on the basis of a cross-linguistic survey of such expressions, that in many cases they motivate a syntactic category which is distinct from both N and P, which I call AxPart for ‘Axial Part’; I show how the category relates to the words which instantiate it, and how the meaning of the construction is derived from the combination of P[lace] elements, AxParts, and the lexical material which expresses them.

  14. Unsteady Flows in Axial Turbomachines

    Science.gov (United States)

    Marble, F. E.; Rannie, W. D.

    1957-01-01

    Of the various unsteady flows that occur in axial turbomachines certain asymmetric disturbances, of wave length large in comparison with blade spacing, have become understood to a certain extent. These disturbances divide themselves into two categories: self-induced oscillations and force disturbances. A special type of propagating stall appears as a self-induced disturbance; an asymmetric velocity profile introduced at the compressor inlet constitutes a forced disturbance. Both phenomena have been treated from a unified theoretical point of view in which the asymmetric disturbances are linearized and the blade characteristics are assumed quasi-steady. Experimental results are in essential agreement with this theory wherever the limitations of the theory are satisfied. For the self-induced disturbances and the more interesting examples of the forced disturbances, the dominant blade characteristic is the dependence of total pressure loss, rather than the turning angle, upon the local blade inlet angle.

  15. Examination of forensic entomology evidence using computed tomography scanning: case studies and refinement of techniques for estimating maggot mass volumes in bodies.

    Science.gov (United States)

    Johnson, Aidan; Archer, Melanie; Leigh-Shaw, Lyndie; Pais, Mike; O'Donnell, Chris; Wallman, James

    2012-09-01

    A new technique has recently been developed for estimating the volume of maggot masses on deceased persons using post-mortem CT scans. This allows volume to be measured non-invasively and factored into maggot mass temperature calculations for both casework and research. Examination of admission scans also allows exploration of entomological evidence in anatomical areas not usually exposed by autopsy (e.g. nasal cavities and facial sinuses), and before autopsy disrupts the maggot distribution on a body. This paper expands on work already completed by providing the x-ray attenuation coefficient by way of Hounsfield unit (HU) values for various maggot species, maggot masses and human tissue adjacent to masses. Specifically, this study looked at the HU values for four forensically important blowfly larvae: Lucilia cuprina, L. sericata, Calliphora stygia and C. vicina. The Calliphora species had significantly lower HU values than the Lucilia species. This might be explained by histological analysis, which revealed a non-significant trend, suggesting that Calliphora maggots have a higher fat content than the Lucilia maggots. It is apparent that the variation in the x-ray attenuation coefficient usually precludes its use as a tool for delineating the maggot mass from human tissue and that morphology is the dominant method for delineating a mass. This paper also includes three case studies, which reveal different applications for interpreting entomological evidence using post-mortem CT scans.

  16. Health and imaging outcomes in axial spondyloarthritis

    NARCIS (Netherlands)

    Machado, P.M.

    2016-01-01

    This thesis focuses on the assessment and monitoring of health and imaging outcomes in axial spondyloarthritis (SpA) and the relationship between these outcomes. Four major contributions to the understanding and management of axial SpA were made: 1) the improvement and facilitation of the assessment

  17. Cubic meter volume optical coherence tomography

    Science.gov (United States)

    WANG, ZHAO; POTSAID, BENJAMIN; CHEN, LONG; DOERR, CHRIS; LEE, HSIANG-CHIEH; NIELSON, TORBEN; JAYARAMAN, VIJAYSEKHAR; CABLE, ALEX E.; SWANSON, ERIC; FUJIMOTO, JAMES G.

    2017-01-01

    Optical coherence tomography (OCT) is a powerful three-dimensional (3D) imaging modality with micrometer-scale axial resolution and up to multi-GigaVoxel/s imaging speed. However, the imaging range of high-speed OCT has been limited. Here, we report 3D OCT over cubic meter volumes using a long coherence length, 1310 nm vertical-cavity surface-emitting laser and silicon photonic integrated circuit dual-quadrature receiver technology combined with enhanced signal processing. We achieved 15 µm depth resolution for tomographic imaging at a 100 kHz axial scan rate over a 1.5 m range. We show 3D macroscopic imaging examples of a human mannequin, bicycle, machine shop gauge blocks, and a human skull/brain model. High-bandwidth, meter-range OCT demonstrates new capabilities that promise to enable a wide range of biomedical, scientific, industrial, and research applications. PMID:28239628

  18. Investigation of Valve Plate in Water Hydraulic Axial Piston Motor

    Institute of Scientific and Technical Information of China (English)

    聂松林; 李壮云; 等

    2002-01-01

    This paper has introduced the developments of water hydraulic axial piston equipments.According to the effects of physicochemical properties of water on water hydraulic components,a novel valve plate for water hydraulic axial motor has been put forward,whose moment exerted by the fluid field between valve plate and bearing plate is balanced entirely.The material screening experiment of valve plate is done on the test rig.Through numerical simulation the effects of some geometry parameters on the performance of water hydraulic motor have been studied.The silencing grooves on the valve plate in water hydraulic motor can reduce the pressure shock and the occurrence of cavitation effectively.It is evident that the appropriate structure should change the wear status between matching paris and reduces the wear and specific pressure of the matching pairs.The specimen with the new type valve plate is used in a tool system.

  19. Homodyne en face optical coherence tomography

    OpenAIRE

    Yaqoob, Zahid; Fingler, Jeff; Heng, Xin; Yang, Changhuei

    2006-01-01

    We demonstrate, for what we believe to be the first time, the use of a 3×3 fiber-optic coupler to realize a homodyne optical coherence tomography (OCT) system for en face imaging of highly scattering tissues and turbid media. The homodyne OCT setup exploits the inherent phase shifts between different output ports of a 3×3 fiber-optic coupler to extract amplitude information of a sample. Our homodyne en face OCT system features a measured resolution of 14 μm axially and 9.4 μm laterally with a...

  20. Axial force measurement for esophageal function testing

    Institute of Scientific and Technical Information of China (English)

    Flemming H Gravesen; Peter Funch-Jensen; Hans Gregersen; Asbjφrn Mohr Drewes

    2009-01-01

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.

  1. Axial force measurement for esophageal function testing.

    Science.gov (United States)

    Gravesen, Flemming H; Funch-Jensen, Peter; Gregersen, Hans; Drewes, Asbjørn Mohr

    2009-01-14

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.

  2. Computed Tomography (CT) - Spine

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Spine Computed tomography (CT) of the ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  3. Computed Tomography (CT) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  5. New Anomaly of the Axial-Vector Current

    Institute of Scientific and Technical Information of China (English)

    HE Han-Xin

    2001-01-01

    By computing the axial-vector current operator equation, we find the anomalous axial-vector curl equation besides the well-known anomalous axial-vector divergence equation (the Adler-Bell-Jackiw anomaly) and discuss its implication.``

  6. Práticas cirúrgicas baseadas em evidências: tomografia computadorizada helicoidal no diagnóstico da apendicite aguda Evidence-based surgical practices: helical computed tomography in acute appendicitis diagnosis

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Guimarães

    2008-08-01

    Full Text Available Os cirurgiões são instados a não somente ler os artigos dos periódicos, mas também a compreendê-los e analisá-los criticamente quanto à validade. Eles cuidam melhor dos seus pacientes se são capazes de analisar criticamente a literatura e aplicar os resultados a sua prática. Este é o segundo artigo de uma série - Práticas Cirúrgicas Baseadas em Evidência - que tem por objetivo apresentar a avaliação crítica de um teste diagnóstico.Surgeons are told that they need not only read journal articles, but also understand them and make a critical appraisal of their validity. They offer better care if they are able to appraise critically the original literature and apply the results to their practice. This is the second article of a series - Evidence-Based Surgical Practices - which focus on critical appraisal of a diagnostic test.

  7. ASAS classification criteria for axial spondyloarthritis: time to modify.

    Science.gov (United States)

    Akkoc, Nurullah; Khan, Muhammad A

    2016-06-01

    The relationship between ankylosing spondylitis and the recently proposed entity called axial spondyloarthritis with its radiographic and non-radiographic forms that have been defined by the Assessment of Spondyloarthritis International Society (ASAS) criteria for axial spondyloarthritis (axSpA), is currently being debated. The Food and Drug Agency (FDA) had criticized the ASAS criteria and the studies which used these criteria to enroll patients in a clinical trial of certolizumab and adalimumab for the treatment of non-radiographic axial spondyloarthritis. The primary aim of classification criteria is to create homogenous patient populations for basic and clinical research. But the multi-arm construct of the ASAS criteria is a potential source of heterogeneity reducing their utility. Criteria sets should be regarded as dynamic concepts open to modifications or updates as our knowledge advances. We provide evidence to conclude that it is time to modify the ASAS Criteria for axSpA, and we propose some of the steps that can be taken to start moving forward in improving the validity of these criteria.

  8. High-resolution second harmonic optical coherence tomography

    Science.gov (United States)

    Jiang, Yi; Tomov, Ivan V.; Wang, Yimin; Chen, Zhongping

    2005-04-01

    A high-resolution Second Harmonic Optical Coherence Tomography (SH-OCT) system is demonstrated using a spectrum broadened femtosecond Ti:sapphire laser. An axial resolution of 4.2 μm at the second harmonic wave center wavelength of 400 nm has been achieved. Because the SH-OCT system uses the second harmonic generation signals that strongly depend on the orientation, polarization and local symmetry properties of chiral molecules, this technique provides unique contrast enhancement to conventional optical coherence tomography. The system is applied to image biological tissues like the rat-tail tendon. Images of highly organized collagen fibrils in the rat-tail tendon have been demonstrated.

  9. Axial thermal rotation of slender rods.

    Science.gov (United States)

    Li, Dichuan; Fakhri, Nikta; Pasquali, Matteo; Biswal, Sibani Lisa

    2011-05-06

    Axial rotational diffusion of rodlike polymers is important in processes such as microtubule filament sliding and flagella beating. By imaging the motion of small kinks along the backbone of chains of DNA-linked colloids, we produce a direct and systematic measurement of axial rotational diffusivity of rods both in bulk solution and near a wall. The measured diffusivities decrease linearly with the chain length, irrespective of the distance from a wall, in agreement with slender-body hydrodynamics theory. Moreover, the presence of small kinks does not affect the chain's axial diffusivity. Our system and measurements provide insights into fundamental axial diffusion processes of slender objects, which encompass a wide range of entities including biological filaments and linear polymer chains.

  10. How to diagnose axial spondyloarthritis early

    OpenAIRE

    Rudwaleit, M.; van der Heijde, D.; Khan, M.; Braun, J.; Sieper, J.

    2004-01-01

    Background: Chronic low back pain (LBP), the leading symptom of ankylosing spondylitis (AS) and undifferentiated axial spondyloarthritis (SpA), precedes the development of radiographic sacroiliitis, sometimes by many years.

  11. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans

    2009-01-01

    force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been...... force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...... documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe...

  12. Numerical simulation of axial flow compressors.

    OpenAIRE

    Jesuino Takachi Tomita

    2002-01-01

    This work deals with the numerical simulation of axial flow compressors, from design to performance prediction. The stage performance prediction uses the meanline flow properties. Stage-stacking is used to analyse a multi-stage compressor. A computer program, written in FORTRAN, was developed and is able to design an axial flow compressor given air mass flow, total pressure ratio, overall efficiency and design speed. All geometrical data relevant to the compressor performance prediction is ca...

  13. Nonperturbative Aspects of Axial Vector Vertex

    Institute of Scientific and Technical Information of China (English)

    ZONG Hong-Shi; CHEN Xiang-Song; WANG Fan; CHANG Chao-Hsi; ZHAO En-Guang

    2002-01-01

    It is shown how the axial vector current of current quarks is related to that of constituent quarks within the framework of the global color symmetry model.Gluon dressing of the axial vector vertex and the quark self-energy functions are described by the inhomogeneous Bethe-Salpeter equation in the ladder approximation and the Schwinger Dyson equation in the rainbow approximation,respectively.

  14. A Cone Beam Computed Tomography (CBCT) evaluation of MB2 canals in endodontically treated permanent maxillary molars. A retrospective study in Indian population

    Science.gov (United States)

    Sontakke, Subodh; Karjodkar, Freny; Gupta, Pankaj; Mandwe, Ashish; Banga, K.S

    2017-01-01

    Background Current technological advances have allowed application of different study designs and techniques for investigation of dental anatomy. Some clinical studies have provided evidence that Cone Beam computed tomography (CBCT) scanning is an important resource in assessment of root canal systems notably to identify MB2 canals in maxillary molars as CBCT scans allow in vivo dental investigation in axial, sagittal and coronal planes simultaneously. The current study was undertaken to detect and evaluate filled/unfilled MB2 canals in endodontically treated, asymptomatic maxillary molars utilizing cone beam computed tomography (CBCT). Material and Methods A retrospective study of 100 CBCTs of patients were underwent scanning for various treatment modalities, with asymptomatic endodontically treated permanent first and second maxillary molars were selected. History of root canal treatment varied from minimum of 1 year to a maximum of 10 years. Axial and paraxial images obtained were used to assess the presence of MB2 canal. Paraxial images were used to assess the periapical status. Results Of the 100 scans, 66 were of permanent maxillary first molar and 34 were of permanent maxillary second molar. The incidence of MB2 canal was 86.36% in maxillary first molars and 29.4% in maxillary second molars. 77.19 % of maxillary first molars and 90% of maxillary second molars had an unfilled MB2 canal. 72.7% of maxillary first molars and 88.8% of maxillary second molars showed significant periapical radiolucencies in unfilled MB2 canals. Conclusions MB2 canals were present in majority of cases and most of the unfilled MB2 canals showed evidence of periapical radiolucencies. Key words:MB2 Canals, Cone Beam computed Tomography (CBCT), Filled /Unfilled canals, Endodontically treated teeth. PMID:28149463

  15. Meaning of Interior Tomography

    CERN Document Server

    Wang, Ge

    2013-01-01

    The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as omni-tomography is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features.

  16. SU(3)--Breaking Effects in Axial--Vector Couplings of Octet Baryons

    CERN Document Server

    Gensini, P M; Gensini, Paolo M.; Violini, Galileo

    1993-01-01

    Present evidence on baryon axial--vector couplings is reviewed, the main emphasis being on internal consistency between asymmetry and rate data. A complete account of all {\\sl small} terms in the Standard Model description of these latter leads to {\\sl both} consistency {\\sl and} evidence for breaking of flavour SU(3) in the axial couplings of octet baryons. Talk presented at "5th Int. Sympos. on Meson--Nucleon Physics and the Structure of the Nucleon", Boulder, CO, sept. 1993. To be published in $\\pi N$ Newsletter.

  17. Axial Permanent Magnet Generator for Wearable Energy Harvesting

    DEFF Research Database (Denmark)

    Högberg, Stig; Sødahl, Jakob Wagner; Mijatovic, Nenad

    2016-01-01

    An increasing demand for battery-free electronics is evident by the rapid increase of wearable devices, and the design of wearable energy harvesters follows accordingly. An axial permanent magnet generator was designed to harvest energy from human body motion and supplying it to a wearable......W, respectively) with an iron yoke is subject to losses that exceed the realistic input power, and was therefore deemed infeasible. A generator without the iron yoke was concluded to perform well as a wearable energy harvester. An experimental investigation of a prototype revealed an output power of almost 1 m...

  18. Wave propagation in axially moving periodic strings

    Science.gov (United States)

    Sorokin, Vladislav S.; Thomsen, Jon Juel

    2017-04-01

    The paper deals with analytically studying transverse waves propagation in an axially moving string with periodically modulated cross section. The structure effectively models various relevant technological systems, e.g. belts, thread lines, band saws, etc., and, in particular, roller chain drives for diesel engines by capturing both their spatial periodicity and axial motion. The Method of Varying Amplitudes is employed in the analysis. It is shown that the compound wave traveling in the axially moving periodic string comprises many components with different frequencies and wavenumbers. This is in contrast to non-moving periodic structures, for which all components of the corresponding compound wave feature the same frequency. Due to this "multi-frequency" character of the wave motion, the conventional notion of frequency band-gaps appears to be not applicable for the moving periodic strings. Thus, for such structures, by frequency band-gaps it is proposed to understand frequency ranges in which the primary component of the compound wave attenuates. Such frequency band-gaps can be present for a moving periodic string, but only if its axial velocity is lower than the transverse wave speed, and, the higher the axial velocity, the narrower the frequency band-gaps. The revealed effects could be of potential importance for applications, e.g. they indicate that due to spatial inhomogeneity, oscillations of axially moving periodic chains always involve a multitude of frequencies.

  19. An Unbroken Axial Vector Current Conservation Law

    CERN Document Server

    Sharafiddinov, Rasulkhozha S

    2015-01-01

    The mass, energy and momentum of the neutrino of a true flavor have an axial-vector nature. As a consequence, the left-handed truly neutral neutrino in an axial-vector field of emission can be converted into a right-handed one and vice versa. This predicts the unidenticality of masses, energies and momenta of neutrinos of the different components. Recognizing such a difference in masses, energies, momenta and accepting that the left-handed axial-vector neutrino and the right-handed antineutrino of true neutrality refer to long-lived C-odd leptons, and the right-handed truly neutral neutrino and the left-handed axial-vector antineutrino are of short-lived fermions of C-oddity, we would write a new CP-even Dirac equation taking into account the flavor symmetrical axial-vector mass, energy and momentum matrices. Their presence explains the spontaneous mirror symmetry violation, confirming that an axial-vector current conservation law has never violated. They reflect the availability of a mirror Minkowski space i...

  20. Parallel optical coherence tomography using a CCD camera

    Institute of Scientific and Technical Information of China (English)

    Junle Qu(屈军乐); Ravi S.Jonnal; Donald T. Miller

    2004-01-01

    Parallel optical coherence tomography is demonstrated using a 12-bit scientific-grade charge-coupled device array.A superluminescent diode in combination with a free-space Michelson interferometer was employed to achieve 10-μm axial resolution and 1.1-μm transverse resolution on a 902×575 μm2 field of view.We imaged a test mirror and bovine retinal tissue using a four-step phase shift method.

  1. Hypoplasia of the parotid gland: computed tomography sialography diagnosis.

    Science.gov (United States)

    Sun, Lisha; Sun, Zhipeng; Ma, Xuchen

    2013-10-01

    We report two unusual cases of non-syndromic hypoplasia of the parotid gland. The hypoplastic parotid gland mimicked a preauricular parotid tumor in one case and presented as an incidental image finding in the other case. Absence of the deep lobe and isthmus of the parotid parenchyma could be determined on axial computed tomography (CT) by revealing fat tissue composition of the parotid space. The underdeveloped superficial lobe of the gland was observed on three-dimensional CT sialography.

  2. Three-dimensional computed tomography of the acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, R.S.; Muner, G.; Pozzi Mucelli, F.; Pozzi Mucelli, M.; Marotti, F.; Dalla Palma, L.

    1986-08-01

    Acetabular fractures represent a complex variety that are classified in different types. Conventional radiology is often inadequate to demonstrate and classify the fractures. Computed tomography (CT) has already been shown to be superior in this field. A further advantage of CT is represented by the recent availability of three-dimensional (3D) images that are realized from axial CT scans by means of a new software. The Authors report the applications of this new software to the study of the normal acetabulum and in patients with fractures. 3D images allows an effective demonstration of the fracture, its irradiation and the dislocation of bone fragments. The information is contained in one or few images rather than many axial images. Therefore the role of 3D images may be considered complementary to axial CT scans.

  3. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  4. Turbocharging Quantum Tomography.

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J; Gamble, John King,; Nielsen, Erik; Maunz, Peter Lukas Wilhelm; Scholten, Travis L.; Rudinger, Kenneth Michael

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography su %7C ers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more e %7C ectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  5. Optimization of residual heat removal pump axial thrust and axial bearing

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  6. Reducing axial mixing in flotation columns

    Energy Technology Data Exchange (ETDEWEB)

    Al Taweel, A.M.; Ramadan, A.M. [Technical Univ. of Nova Scotia, Halifax (Canada). Chemical Engineering Dept.; Moharam, M.R.; Hassan, T.A. [Al Azhar Univ., Cairo (Egypt); El Mofty, S.M. [Cairo Univ., Giza (Egypt)

    1995-10-01

    The axial mixing characteristics of a pilot-scale flotation column were investigated with the objective of identifying means to mitigate the extent of axial mixing that adversely affects its grade/recovery performance. A wide range of design and operating conditions wa investigated and the experimental results, obtained using the dynamic response method, were analyzed using three axial mixing models. The dynamic response of the column can best be described using the axial dispersion model. The results obtained suggest that the value of the axial dispersion coefficient, E{sub L}, can be significantly reduced by judicial selection of hydrodynamic conditions and/or the use of column inserts that suppress the onset of hydrodynamic instabilities inherent to the operation of conventional flotation columns. Up to 40% reduction in the value of E{sub L} was thus obtained by using spargers that produce more uniform bubble sizes, while up to 30% reductions were obtained by controlling the residual frother concentration. 33 refs., 7 figs.

  7. Improving the lattice axial vector current

    Energy Technology Data Exchange (ETDEWEB)

    Horsley, R. [Edinburgh Univ. (United Kingdom). School of Physics and Astronomy; Nakamura, Y. [RIKEN Advanced Institute for Computational Science, Kobe (Japan); Perlt, H.; Schiller, A. [Leipzig Univ. (Germany). Inst. fuer Theoretische Physik; Rakow, P.E.L. [Liverpool Univ. (United Kingdom). Theoretical Physics Div.; Schierholz, G. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Zanotti, J.M. [Adelaide Univ. (Australia). CSSM, Dept. of Physics

    2015-11-15

    For Wilson and clover fermions traditional formulations of the axial vector current do not respect the continuum Ward identity which relates the divergence of that current to the pseudoscalar density. Here we propose to use a point-split or one-link axial vector current whose divergence exactly satisfies a lattice Ward identity, involving the pseudoscalar density and a number of irrelevant operators. We check in one-loop lattice perturbation theory with SLiNC fermion and gauge plaquette action that this is indeed the case including order O(a) effects. Including these operators the axial Ward identity remains renormalisation invariant. First preliminary results of a nonperturbative check of the Ward identity are also presented.

  8. Axial flow positive displacement worm gas generator

    Science.gov (United States)

    Murrow, Kurt David (Inventor); Giffin, Rollin George (Inventor); Fakunle, Oladapo (Inventor)

    2010-01-01

    An axial flow positive displacement engine has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first, second, and third sections of a core assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. The first twist slopes are less than the second twist slopes and the third twist slopes are less than the second twist slopes. A combustor section extends axially downstream through at least a portion of the second section.

  9. Axial symmetry and conformal Killing vectors

    CERN Document Server

    Mars, M; Mars, Marc; Senovilla, Jose M.M.

    1993-01-01

    Axisymmetric spacetimes with a conformal symmetry are studied and it is shown that, if there is no further conformal symmetry, the axial Killing vector and the conformal Killing vector must commute. As a direct consequence, in conformally stationary and axisymmetric spacetimes, no restriction is made by assuming that the axial symmetry and the conformal timelike symmetry commute. Furthermore, we prove that in axisymmetric spacetimes with another symmetry (such as stationary and axisymmetric or cylindrically symmetric spacetimes) and a conformal symmetry, the commutator of the axial Killing vector with the two others mush vanish or else the symmetry is larger than that originally considered. The results are completely general and do not depend on Einstein's equations or any particular matter content.

  10. Atlanto-axial infection after acupuncture.

    Science.gov (United States)

    Robinson, A; Lind, C R P; Smith, R J; Kodali, V

    2015-12-11

    A 67-year-old man presented with neck cellulitis following acupuncture for cervical spondylosis. Blood cultures were positive for methicillin-sensitive Staphylococcus aureus. Increased neck pain and bacteraemia prompted MRI, which showed atlanto-axial septic arthritis without signs of infection of the tissues between the superficial cellulitic area and the atlanto-axial joint, thus making direct extension of infection unlikely. It is more likely that haematogenous spread of infection resulted in seeding in the atlanto-axial joint, with the proximity of the arthritis and acupuncture site being coincidental. Acupuncture is a treatment option for some indolent pain conditions. As such, acupuncture services are likely to be more frequently utilised. A history of acupuncture is rarely requested by the admitting doctor and seldom offered voluntarily by the patient, especially where the site of infection due to haematogenous spread is distant from the needling location. Awareness of infectious complications following acupuncture can reduce morbidity through early intervention.

  11. Improving the lattice axial vector current

    CERN Document Server

    Horsley, R; Perlt, H; Rakow, P E L; Schierholz, G; Schiller, A; Zanotti, J M

    2015-01-01

    For Wilson and clover fermions traditional formulations of the axial vector current do not respect the continuum Ward identity which relates the divergence of that current to the pseudoscalar density. Here we propose to use a point-split or one-link axial vector current whose divergence exactly satisfies a lattice Ward identity, involving the pseudoscalar density and a number of irrelevant operators. We check in one-loop lattice perturbation theory with SLiNC fermion and gauge plaquette action that this is indeed the case including order $O(a)$ effects. Including these operators the axial Ward identity remains renormalisation invariant. First preliminary results of a nonperturbative check of the Ward identity are also presented.

  12. Axial loaded MRI of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Saifuddin, A. E-mail: asaifuddin@aol.com; Blease, S.; MacSweeney, E

    2003-09-01

    Magnetic resonance imaging is established as the technique of choice for assessment of degenerative disorders of the lumbar spine. However, it is routinely performed with the patient supine and the hips and knees flexed. The absence of axial loading and lumbar extension results in a maximization of spinal canal dimensions, which may in some cases, result in failure to demonstrate nerve root compression. Attempts have been made to image the lumbar spine in a more physiological state, either by imaging with flexion-extension, in the erect position or by using axial loading. This article reviews the literature relating to the above techniques.

  13. Axial Nucleon form factors from lattice QCD

    CERN Document Server

    Alexandrou, C; Carbonell, J; Constantinou, M; Harraud, P A; Guichon, P; Jansen, K; Korzec, T; Papinutto, M

    2010-01-01

    We present results on the nucleon axial form factors within lattice QCD using two flavors of degenerate twisted mass fermions. Volume effects are examined using simulations at two volumes of spatial length $L=2.1$ fm and $L=2.8$ fm. Cut-off effects are investigated using three different values of the lattice spacings, namely $a=0.089$ fm, $a=0.070$ fm and $a=0.056$ fm. The nucleon axial charge is obtained in the continuum limit and chirally extrapolated to the physical pion mass enabling comparison with experiment.

  14. Optimization of Axial Intensity Point Spread Function

    Institute of Scientific and Technical Information of China (English)

    WANG Haifeng; GAN Fuxi; CHEN Zhongyu

    2001-01-01

    It is known that for the converged laser beam, the axial intensity distribution corresponds to a Gaussian curve, that is, the intensity on the focal plane is the peak intensity. When it defocuses, the intensity would decrease rapidly. In optical data storage, for instance, we expect the intensity within a certain distance to be almost equal. In this paper, we propose to use a pure phase superresolution apodizer to optimize the axial intensity distribution of the converged laser beam and at the same time improve the resolution. The intensity point spread function remains almost identical in a wide range within the focal depth.

  15. «FLARES» IN AXIAL SPONDYLOARTHRITIS

    Directory of Open Access Journals (Sweden)

    Sh. F. Erdes

    2016-01-01

    Full Text Available The clear definition of the concept of «flare in axial spondyloarthritis» is of paramount importance for clinical trials and routine practice in particular. It will be able to unify the characteristics of outcomes over a particular period of time on the one hand and to standardize therapeutic approaches on the other. On 4 February 2016, the journal Annals of Rheumatic Diseases published the on-line paper «Preliminary definitions of 'flare' in axial spondyloarthritis, based on pain, BASDAI and ASDAS-CRP: an ASAS initiative» by L. Gossec et al., which was devoted to this topic.

  16. Optical Coherence Tomography for the Assessment of Coronary Atherosclerosis and Vessel Response after Stent Implantation

    NARCIS (Netherlands)

    N. Gonzalo (Nieves)

    2010-01-01

    textabstractOptical Coherence Tomography (OCT) is a light-based imaging modality that can provide in vivo high-resolution images of the coronary artery with a level of resolution (axial 10-20 µm) ten times higher than intravascular ultrasound. The technique, uses low-coherent near infrarred light t

  17. Estimation of Chromatographic Columns Performances using Computer Tomography and CFD Simulations

    DEFF Research Database (Denmark)

    Schmidt, Irma; Lottes, Florian; Minceva, Mirjana;

    2011-01-01

    The flow inside a chromatographic column depends decisively on the packed bed inside. Non‐destructive X‐ray computed tomography (CT) was applied as a novel measurement technique to visualize the distribution of velocity and axial dispersion coefficients in preparative scale columns. The results s...

  18. Estudo de caso de oferta induzindo a demanda: o caso da oferta de exames de imagem (tomografia axial computadorizada e ressonância magnética na Unimed-Manaus Case study of supply induced demand: the case of provision of imaging scans (computed tomography and magnetic resonance at Unimed-Manaus

    Directory of Open Access Journals (Sweden)

    Edson de Oliveira Andrade

    2011-04-01

    Full Text Available OBJETIVO: Apresentar a experiência de uma operadora de plano de saúde (Unimed-Manaus na cidade de Manaus, Estado do Amazonas, com o credenciamento de serviços de imagem e a indução de demanda pela oferta dos novos serviços (Lei de Roemer. MÉTODOS: Trata-se de uma pesquisa de caráter retrospectivo, com estudo de série temporal, abordando o período de janeiro de 1998 a junho de 2004, lapso de tempo em que ocorreu a implantação dos serviços de tomografia computadorizada e da ressonância magnética no âmbito dos serviços oferecidos por aquele plano de saúde. A análise estatística consistiu em uma parte descritiva e uma inferencial, sendo esta última utilizando teste paramétrico de média (teste t de Student e ANOVA e o teste de correlação de Pearson. Foi adotado um alfa de 5% e um intervalo de confiança de 95%. RESULTADOS: Foi possível identificar na Unimed-Manaus que a oferta de novos serviços de imagem foi capaz de, por si só, gerar um aumento da demanda do serviço caracterizando o fenômeno descrito por Roemer. CONCLUSÃO: Os resultados deste trabalho ressaltam a necessidade de se estar atento ao fato de que a oferta de novos serviços no setor da saúde poderá acarretar, por si só, um aumento de sua utilização sem que haja uma demanda real.OBJECTIVE: To present the experience of a health plan operator (Unimed-Manaus in Manaus, Amazonas, Brazil, with the accreditation of imaging services and the demand induced by the supply of new services (Roemer's Law. METHODS: This is a retrospective work studying a time series covering the period from January 1998 to June 2004, in which the computed tomography and the magnetic resonance imaging services were implemented as part of the services offered by that health plan operator. Statistical analysis consisted of a descriptive and an inferential part, with the latter using a mean parametric test (Student T-test and ANOVA and the Pearson correlation test. A 5% alpha and a 95

  19. Tomography of nonclassical states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    A review of the symplectic tomography method is presented. Superpositions of different types of photon states are considered within the framework of the tomography approach. Such nonclassical photon states as even and odd coherent states, crystallized Schrodinger cat states, and other superposition

  20. Ridge asymmetry and deep aqueous alteration at the trench observed from Rayleigh wave tomography of the Juan de Fuca plate

    Science.gov (United States)

    Bell, Samuel; Ruan, Youyi; Forsyth, Donald W.

    2016-10-01

    Using Rayleigh wave tomography of noise-removed ocean bottom seismometer data from the Cascadia Initiative, we illuminate the structure of the upper mantle beneath the Juan de Fuca plate. Beneath the Juan de Fuca ridge, there is strong asymmetry, with a pronounced low-velocity zone in the 25-65 km depth range. Extending to the west from the spreading axis, this anomaly has velocities low enough to indicate the presence of melt. The asymmetry in velocity structure and the much greater abundance of seamounts on the west flank of the ridge suggest that dynamic, buoyant upwelling is important, perhaps triggered by thermal or compositional anomalies beneath Axial Seamount. In contrast, there is no evidence for asymmetry in the axial zone or lower than expected velocities beneath the Gorda ridge. On the eastern flank of the Juan de Fuca ridge, the shear velocity in the 25-65 depth range is higher than expected; the lithosphere appears to be colder and thicker than predicted by standard plate cooling models, perhaps caused by the downwelling counterpart of the upwelling on the west side of the ridge. Close to the trench, there is a sharp decrease in shear velocity. We interpret this as aqueous alteration caused by hydrothermal circulation through deep normal faults associated with bending of the plate. Beneath the Astoria and Nitinat fans, where abyssal plain sediment is thickest, the velocity decrease is much smaller, which is consistent with a thick sediment cap that prevents hydrothermal alteration of the plate.

  1. Investigations on Experimental Impellers for Axial Blowers

    Science.gov (United States)

    Encke, W.

    1947-01-01

    A selection of measurements obtained on experimental impellers for axial blowers will be reported. In addition to characteristic curves plotted for low and for high peripheral velocities, proportions and blade sections for six different blower models and remarks on the design of blowers will be presented.

  2. Excitation modes in non-axial nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Leviatan, A.; Ginnochio, J.N.

    1990-01-01

    Excitation modes of non-axial quadrupole shapes are investigated in the framework of interacting boson models. Both {gamma}-unstable and {gamma}-rigid nuclear shapes are considered for systems with one type of boson as well as with proton-neutron bosons. 6 refs.

  3. Ankylosing Spondylitis versus Nonradiographic Axial Spondyloarthritis

    DEFF Research Database (Denmark)

    Glintborg, Bente; Sørensen, Inge J; Østergaard, Mikkel

    2017-01-01

    OBJECTIVE: To compare baseline disease activity and treatment effectiveness in biologic-naive patients with nonradiographic axial spondyloarthritis (nr-axSpA) and ankylosing spondylitis (AS) who initiate tumor necrosis factor inhibitor (TNFi) treatment and to study the role of potential confounders...

  4. Wave propagation in axially moving periodic strings

    DEFF Research Database (Denmark)

    Sorokin, Vladislav S.; Thomsen, Jon Juel

    2017-01-01

    The paper deals with analytically studying transverse waves propagation in an axially moving string with periodically modulated cross section. The structure effectively models various relevant technological systems, e.g. belts, thread lines, band saws, etc., and, in particular, roller chain drive...

  5. The spacetime outside a source of gravitational radiation: The axially symmetric null fluid

    CERN Document Server

    Herrera, L; Ospino, J

    2016-01-01

    We carry out a study of the exterior of an axially and reflection symmetric source of gravitational radiation. The exterior of such a source is filled with a null fluid produced by the dissipative processes inherent to the emission of gravitational radiation, thereby representing a generalization of the Vaidya metric for axially and reflection symmetric spacetimes. The role of the vorticity, and its relationship with the presence of gravitational radiation is put in evidence. The spherically symmetric case (Vaidya) is, asymptotically, recovered within the context of the $1+3$ formalism.

  6. The space-time outside a source of gravitational radiation: the axially symmetric null fluid

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, L. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Universidad de Salamanca, Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain); Di Prisco, A. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Ospino, J. [Universidad de Salamanca, Departamento de Matematica Aplicada and Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain)

    2016-11-15

    We carry out a study of the exterior of an axially and reflection symmetric source of gravitational radiation. The exterior of such a source is filled with a null fluid produced by the dissipative processes inherent to the emission of gravitational radiation, thereby representing a generalization of the Vaidya metric for axially and reflection symmetric space-times. The role of the vorticity, and its relationship with the presence of gravitational radiation is put in evidence. The spherically symmetric case (Vaidya) is, asymptotically, recovered within the context of the 1 + 3 formalism. (orig.)

  7. Might axial myofascial properties and biomechanical mechanisms be relevant to ankylosing spondylitis and axial spondyloarthritis?

    OpenAIRE

    Masi, Alfonse T.

    2014-01-01

    Ankylosing spondylitis and axial spondyloarthropathy have characteristic age- and sex-specific onset patterns, typical entheseal lesions, and marked heritability, but the integrative mechanisms causing the pathophysiological and structural alterations remain largely undefined. Myofascial tissues are integrated in the body into webs and networks which permit transmission of passive and active tensional forces that provide stabilizing support and help to control movements. Axial myofascial hype...

  8. Influence of tip clearance on pressure fluctuations in an axial flow pump

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Jianjun; Luo, Xingqi; Guo, Pengcheng; Wu, Guangkuan [Xi' an University, Xi' an (China)

    2016-04-15

    Rotor-stator interaction in axial pumps can produce pressure fluctuations and further vibrations even damage to the pump system in some extreme case. In this paper, the influence of tip clearance on pressure fluctuations in an axial flow water pump has been investigated by numerical method. Three-dimensional unsteady flow in the axial flow water pump has been simulated with different tip clearances between the impeller blade tip and the casing wall. In addition to monitoring pressure fluctuations at some typical points, a new method based on pressure statistics was proposed to determine pressure fluctuations at all grid nodes inside the whole pump. The comparison shows that the existence of impeller tip clearance magnifies the pressure fluctuations in the impeller region, from the hub to shroud. However, the effect on pressure fluctuation in the diffuser region is not evident. Furthermore, the tip clearance vortex has also been examined under different tip clearances.

  9. Geophysical wave tomography

    Science.gov (United States)

    Zhou, Chaoguang

    2000-11-01

    This study is concerned with geophysical wave tomography techniques that include advanced diffraction tomography, traveltime calculation techniques and simultaneous attenuation and velocity tomography approaches. We propose the source independent approximation, the Modified Quasi-Linear approximation and develop a fast and accurate diffraction tomography algorithm that uses this approximation. Since the Modified Quasi-Linear approximation accounts for the scattering fields within scatterers, this tomography algorithm produces better image quality than conventional Born approximation tomography algorithm does with or without the presence of multiple scatterers and can be used to reconstruct images of high contrast objects. Since iteration is not required, this algorithm is efficient. We improve the finite difference traveltime calculation algorithm proposed by Vidale (1990). The bucket theory is utilized in order to enhance the sorting efficiency, which accounts for about ten percent computing time improvement for large velocity models. Snell's law is employed to solve the causality problem analytically, which enables the modified algorithm to compute traveltimes accurately and rapidly for high velocity contrast media. We also develop two simultaneous attenuation and velocity tomography approaches, which use traveltimes and amplitude spectra of the observed data, and discuss some of their applications. One approach is processing geophysical data that come from one single survey and the other deals with the repeated survey cases. These approaches are nonlinear and therefore more accurate than linear tomography. A linear system for wave propagation and constant-Q media are assumed in order to develop the tomography algorithms. These approaches not only produce attenuation and velocity images at the same time but also can be used to infer the physical rock properties, such as the dielectric permittivity, the electric conductivity, and the porosity. A crosshole radar

  10. Axial flow positive displacement worm compressor

    Science.gov (United States)

    Murrow, Kurt David (Inventor); Giffin, Rollin George (Inventor); Fakunle, Oladapo (Inventor)

    2010-01-01

    An axial flow positive displacement compressor has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first and second sections of a compressor assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first and second twist slopes in the first and second sections respectively. The first twist slopes are less than the second twist slopes. An engine including the compressor has in downstream serial flow relationship from the compressor a combustor and a high pressure turbine drivingly connected to the compressor by a high pressure shaft.

  11. Direct optical nanoscopy with axially localized detection

    CERN Document Server

    Bourg, N; Dupuis, G; Barroca, T; Bon, P; Lécart, S; Fort, E; Lévêque-Fort, S

    2014-01-01

    Evanescent light excitation is widely used in super-resolution fluorescence microscopy to confine light and reduce background noise. Herein we propose a method of exploiting evanescent light in the context of emission. When a fluorophore is located in close proximity to a medium with a higher refractive index, its near-field component is converted into light that propagates beyond the critical angle. This so-called Supercritical Angle Fluorescence (SAF) can be captured using a hig-NA objective and used to determine the axial position of the fluorophore with nanometer precision. We introduce a new technique for 3D nanoscopy that combines direct STochastic Optical Reconstruction Microscopy (dSTORM) imaging with dedicated detection of SAF emission. We demonstrate that our approach of a Direct Optical Nanoscopy with Axially Localized Detection (DONALD) yields a typical isotropic 3D localization precision of 20 nm.

  12. Piping inspection carriage having axially displaceable sensor

    Science.gov (United States)

    Zollinger, William T.; Treanor, Richard C.

    1994-01-01

    A pipe inspection instrument carriage for use with a pipe crawler for performing internal inspections of piping surfaces. The carriage has a front leg assembly, a rear leg assembly and a central support connecting the two assemblies and for mounting an instrument arm having inspection instruments. The instrument arm has a y-arm mounted distally thereon for axially aligning the inspection instrumentation and a mounting block, a linear actuator and axial movement arm for extending the inspection instruments radially outward to operably position the inspection instruments on the piping interior. Also, the carriage has a rotation motor and gear assembly for rotating the central support and the front leg assembly with respect to the rear leg assembly so that the inspection instruments azimuthally scan the piping interior. The instrument carriage allows performance of all piping inspection operations with a minimum of moving parts, thus decreasing the likelihood of performance failure.

  13. The genetics of ankylosing spondylitis and axial spondyloarthritis.

    Science.gov (United States)

    Robinson, Philip C; Brown, Matthew A

    2012-08-01

    Ankylosing spondylitis (AS) and spondyloarthritis are strongly genetically determined. The long-standing association with HLA-B27 is well described, although the mechanism by which that association induces AS remains uncertain. Recent developments include the description of HLA-B27 tag single nucleotide polymorphisms in European and Asian populations. An increasing number of non-MHC genetic associations have been reported, which provided amongst other things the first evidence of the involvement of the IL-23 pathway in AS. The association with ERAP1 is now known to be restricted to HLA-B27 positive disease. Preliminary studies on the genetics of axial spondyloarthritis demonstrate a lower HLA-B27 carriage rate compared with AS. Studies with larger samples and including non-European ethnic groups are likely to further advance the understanding of the genetics of AS and spondyloarthritis.

  14. Multimode interaction in axially excited cylindrical shells

    OpenAIRE

    2014-01-01

    Cylindrical shells exhibit a dense frequency spectrum, especially near the lowest frequency range. In addition, due to the circumferential symmetry, frequencies occur in pairs. So, in the vicinity of the lowest natural frequencies, several equal or nearly equal frequencies may occur, leading to a complex dynamic behavior. So, the aim of the present work is to investigate the dynamic behavior and stability of cylindrical shells under axial forcing with multiple equal or nearly equal natural fr...

  15. Axial flux permanent magnet brushless machines

    CERN Document Server

    Gieras, Jacek F; Kamper, Maarten J

    2008-01-01

    Axial Flux Permanent Magnet (AFPM) brushless machines are modern electrical machines with a lot of advantages over their conventional counterparts. They are being increasingly used in consumer electronics, public life, instrumentation and automation system, clinical engineering, industrial electromechanical drives, automobile manufacturing industry, electric and hybrid electric vehicles, marine vessels and toys. They are also used in more electric aircrafts and many other applications on larger scale. New applications have also emerged in distributed generation systems (wind turbine generators

  16. Consistent formulation of the spacelike axial gauge

    Energy Technology Data Exchange (ETDEWEB)

    Burnel, A.; Van der Rest-Jaspers, M.

    1983-12-15

    The usual formulation of the spacelike axial gauge is afflicted with the difficulty that the metric is indefinite while no ghost is involved. We solve this difficulty by introducing a ghost whose elimination is such that the metric becomes positive for physical states. The technique consists in the replacement of the gauge condition nxA = 0 by the weaker one partial/sub 0/nxAroughly-equal0.

  17. Volar morphology of the distal radius in axial planes: a quantitative analysis.

    Science.gov (United States)

    Oura, Keiichiro; Oka, Kunihiro; Kawanishi, Yohei; Sugamoto, Kazuomi; Yoshikawa, Hideki; Murase, Tsuyoshi

    2015-04-01

    To investigate the cause of rupture of the flexor pollicis longus (FPL) after volar plate fixation of distal radius fractures, previous studies have examined the shape of the distal radius in the sagittal plane or in the lateral view. However, there are no reports on the anatomical shape of the volar surface concavity of the distal radius in the axial plane. We hypothesized that this concavity might contribute to the mismatch between the plate and the surface of the radius. To test this hypothesis, we constructed three-dimensional models of the radius and FPL based on computed tomography scans of 70 normal forearms. We analyzed axial cross-sectional views with 2 mm intervals. In all cases, the volar surface of the distal radius was concave in the axial plane. The concavity depth was maximum at 6 mm proximal to the palmar edge of the lunate fossa and progressively decreased toward the proximal radius. FPL was closest to the radius at 2 mm proximal to the palmar edge of the lunate fossa. The volar surface of the distal radius was externally rotated from proximal to distal. These results may help to develop new implants which fit better to the radius and decrease tendon irritation.

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  1. STEM tomography for thick biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Kazuhiro [FEI Company Japan Ltd., Application Laboratory, NSS-II Building, 2-13-34 Kohnan, Minato-ku, Tokyo 108-0075 (Japan)], E-mail: kazuhiro.aoyama@fei.com; Takagi, Tomoko [FEI Company Japan Ltd., Application Laboratory, NSS-II Building, 2-13-34 Kohnan, Minato-ku, Tokyo 108-0075 (Japan); Laboratory of Electron Microscopy, Japan Women' s University, 2-8-1 Mejirodai, Bunkyo-ku, Tokyo 112-8681 (Japan); Hirase, Ai; Miyazawa, Atsuo [Bio-multisome Research Team, RIKEN SPring-8 Center, Harima Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan); CREST, JST (Japan)

    2008-12-15

    Scanning transmission electron microscopy (STEM) tomography was applied to biological specimens such as yeast cells, HEK293 cells and primary culture neurons. These cells, which were embedded in a resin, were cut into 1-{mu}m-thick sections. STEM tomography offers several important advantages including: (1) it is effective even for thick specimens, (2) 'dynamic focusing', (3) ease of using an annular dark field (ADF) mode and (4) linear contrasts. It has become evident that STEM tomography offers significant advantages for the observation of thick specimens. By employing STEM tomography, even a 1-{mu}m-thick specimen (which is difficult to observe by conventional transmission electron microscopy (TEM)) was successfully analyzed in three dimensions. The specimen was tilted up to 73 deg. during data acquisition. At a large tilt angle, the specimen thicknesses increase dramatically. In order to observe such thick specimens, we introduced a special small condenser aperture that reduces the collection angle of the STEM probe. The specimen damage caused by the convergent electron beam was expected to be the most serious problem; however, the damage in STEM was actually smaller than that in TEM. In this study, the irradiation damage caused by TEM- and STEM-tomography in biological specimens was quantitatively compared.

  2. Direct optical nanoscopy with axially localized detection

    Science.gov (United States)

    Bourg, N.; Mayet, C.; Dupuis, G.; Barroca, T.; Bon, P.; Lécart, S.; Fort, E.; Lévêque-Fort, S.

    2015-09-01

    Evanescent light excitation is widely used in super-resolution fluorescence microscopy to confine light and reduce background noise. Here, we propose a method of exploiting evanescent light in the context of emission. When a fluorophore is located in close proximity to a medium with a higher refractive index, its near-field component is converted into light that propagates beyond the critical angle. This so-called supercritical-angle fluorescence can be captured using a high-numerical-aperture objective and used to determine the axial position of the fluorophore with nanometre precision. We introduce a new technique for three-dimensional nanoscopy that combines direct stochastic optical reconstruction microscopy (dSTORM) with dedicated detection of supercritical-angle fluorescence emission. We demonstrate that our approach of direct optical nanoscopy with axially localized detection (DONALD) typically yields an isotropic three-dimensional localization precision of 20 nm within an axial range of ∼150 nm above the coverslip.

  3. Golimumab for the treatment of axial spondyloarthritis.

    Science.gov (United States)

    Gelfer, Gita; Perry, Lisa; Deodhar, Atul

    2016-01-01

    Axial spondyloarthritis (axSpA) is a chronic, immune-mediated inflammatory disease of the axial skeleton that includes ankylosing spondylitis (AS) and non-radiographic axial spondyloarthritis (nr-axSpA). Patients with AS experience chronic pain due to sacroiliac joint and spinal inflammation, and may develop spinal ankylosing with syndesmophyte formation. Tumor necrosis factor α inhibitors (TNFi) have shown promise in the management of AS and axSpA by targeting the underlying inflammatory process, and providing symptomatic relief. Whether they alter the progression of the disease is uncertain. Golimumab is a fully human IgG1 monoclonal antibody that targets and downregulates the pro-inflammatory cytokine TNF-α. The use of golimumab has been shown to reduce the signs and symptoms of axSpA as well as improve patient function and quality reported outcomes. This review focuses on the biological rationale and the results of clinical trials with golimumab for the treatment of axSpA.

  4. 4D Electron Tomography

    OpenAIRE

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-01-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a mov...

  5. Computed tomography imaging strategies and perspectives in orbital fractures

    Directory of Open Access Journals (Sweden)

    Denise Takehana dos Santos

    2007-04-01

    Full Text Available OBJECTIVE: The objective of this study was to demonstrate the sensitivity and specificity of multislice computed tomography (CT for diagnosis of orbital fractures following different protocols, using an independent workstation. MATERIALS AND METHODS: CT images of 36 patients with maxillofacial fractures (symptomatic to orbit region who were submitted to multislice CT scanning were analyzed, retrospectively. The images were interpreted based on 5 protocols, using an independent workstation: 1 axial (original images; 2 multiplanar reconstruction (MPR; 3 3D images; 4 association of axial/MPR/3D images and 5 coronal images. The evaluated anatomical sites were divided according to the orbital walls: lateral (with or without zygomatic frontal process fracture; medial; superior (roof and inferior (anterior, medial. The collected data were analyzed statistically using a validity test (Youden's J index; p<0.05. The clinical and/or surgical findings (medical records were considered as the gold standard to corroborate the diagnosis of the anatomical localization of the orbital fracture. RESULTS: 3D-CT scanning presented sensitivity of 78.9%, which was not superior to that of MPR (84.0%, axial/MPR/3D (90.5% and coronal images (86.1%. On the other hand, the diagnostic value of axial images was considered limited for orbital fractures region, with sensitivity of 44.2%. CONCLUSIONS: Except for the axial images, which presented a low sensitivity, all methods evaluated in this study showed high specificity and sensitivity for the diagnosis of orbital fractures according to the proposed methodology. This protocol can add valuable information to the diagnosis of fractures using the association of axial/MPR/3D with multislice CT.

  6. Axial variation in the three-spine stickleback: genetic and environmental factors.

    Science.gov (United States)

    Ahn, D G; Gibson, G

    1999-01-01

    Subtle differences in the pattern of arrangement of types of vertebrae and associated median skeletal structures between a benthic and limnetic species pair of three-spine stickleback from Paxton Lake, British Columbia, are typical of those found throughout the range of the Gasterosteus aculeatus species complex. We established laboratory colonies from just three individuals of each species, and studied the effect of three generations of inbreeding on axial morphology. There was sufficient divergence in the location of individual elements between families to regenerate close to the entire range of axial diversity seen in threespine sticklebacks worldwide. Analysis of the patterns of variance and covariance between the axial locations of elements provides evidence for the action of both meristic and homeotic processes in the generation of morphological divergence within each species. Hybrid sticklebacks produced by the cross of limnetic and benthic parents tend to have intermediate morphologies, with dominance of either parental type evident for some elements. Effects of temperature and salinity were found to be small in direct comparison with between-family effects, and varied according to genetic background. These results demonstrate that considerable genetic variation for axial morphology is maintained in natural populations of three-spine stickleback, and that differences between populations may be brought about rapidly by changes in frequency of alleles that have coordinated effects along the body axis.

  7. Might axial myofascial properties and biomechanical mechanisms be relevant to ankylosing spondylitis and axial spondyloarthritis?

    Science.gov (United States)

    Masi, Alfonse T

    2014-01-01

    Ankylosing spondylitis and axial spondyloarthropathy have characteristic age- and sex-specific onset patterns, typical entheseal lesions, and marked heritability, but the integrative mechanisms causing the pathophysiological and structural alterations remain largely undefined. Myofascial tissues are integrated in the body into webs and networks which permit transmission of passive and active tensional forces that provide stabilizing support and help to control movements. Axial myofascial hypertonicity was hypothesized as a potential excessive polymorphic trait which could contribute to chronic biomechanical overloading and exaggerated stresses at entheseal sites. Such a mechanism may help to integrate many of the characteristic host, pathological, and structural features of ankylosing spondylitis and axial spondyloarthritis. Biomechanical stress and strain were recently documented to correlate with peripheral entheseal inflammation and new bone formation in a murine model of spondyloarthritis. Ankylosing spondylitis has traditionally been classified by the modified New York criteria, which require the presence of definite radiographic sacroiliac joint lesions. New classification criteria for axial spondyloarthritis now include patients who do not fulfill the modified New York criteria. The male-to-female sex ratios clearly differed between the two patient categories - 2:1 or 3:1 in ankylosing spondylitis and 1:1 in non-radiographic axial spondyloarthritis - and this suggests a spectral concept of disease and, among females, milder structural alterations. Magnetic resonance imaging of active and chronic lesions in ankylosing spondylitis and axial spondyloarthritis reveals complex patterns, usually interpreted as inflammatory reactions, but shows similarities to acute degenerative disc disease, which attributed to edema formation following mechanical stresses and micro-damage. A basic question is whether mechanically induced microinjury and immunologically mediated

  8. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  9. Effects of Axial Non-uniform Tip Clearances on Aerodynamic Performance of a Transonic Axial Compressor

    Institute of Scientific and Technical Information of China (English)

    Hongwei MA; Baihe LI

    2008-01-01

    This paper presents a numerical investigation of effects of axial non-uniform tip clearances on the aerodynamic performance of a transonic axial compressor rotor (NASA Rotor 37). The three-dimensional steady flow field within the rotor passage was simulated with the datum tip clearance of 0.356 mm at the design wheel speed of 17188.7 rpm. The simulation results are well consistent with the measurement results, which verified the numeri-cal method. Then the three-dimensional steady flow field within the rotor passage was simulated respectively with different axial non-uniform tip clearances. The calculation results showed that optimal axial non-uniform tip clearances could improve the compressor performance, while the efficiency and the pressure ratio of the com-pressor were increased. The flow mechanism is that the axial non-uniform tip clearance can weaken the tip leak-age vortex, blow down low-energy fluids in boundary layers and reduce both flow blockage and tip loss.

  10. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Energy Technology Data Exchange (ETDEWEB)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  11. Digital volume tomography for diagnostics in periodontology.

    Science.gov (United States)

    Kasaj, A; Willershausen, B

    2007-04-01

    The impact of radiographic imaging on the diagnosis and treatment of periodontal disease has essentially remained unchanged for decades. Thus, periodontal diagnosis relies primarly on traditional two-dimensional representation of the alveolar bone. Recently, digital volume tomography (DVT) has been introduced for head and neck applications. Major advantages of the DVT are a markedly reduced radiation exposure and superior image quality when compared to conventional computed tomography (CT). With this device, three-dimensional sectional images in the axial, frontal and sagittal plane can be obtained at one examination with tomographic slices of widths ranging from 0.125 to 2 mm. Clinical applications of this unit have been reported for implant site imaging, orthodontics, and temporomandibular joint imaging. Investigations regarding the usefulness of DVT for periodontal applications are still in progress. Thus, a field of interest for the use in periodontology might be the imaging of periodontal intrabony defects, dehiscence and fenestration defects, periodontal cysts as well as the diagnosis of furcation-involved molars.

  12. Facial reconstruction of a 3500-year-old Egyptian mummy using axial computed tomography.

    Science.gov (United States)

    Hill, B; Macleod, I; Watson, L

    1993-01-01

    Rebuilding faces from skulls presented for forensic identification or of historical importance has been carried out for many years using standardized methods. However, the reproduction of the face of a 3500-year-old mummy still enclosed in its cartonnage proved to be an unusual challenge. The face had to be rebuilt without opening the cartonnage to ensure preservation of the remains. Consequently, the method devised involved using the latest medical imaging technology to determine the shape of the skull.

  13. Aerodynamic Modelling and Optimization of Axial Fans

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft

    A numerically efficient mathematical model for the aerodynamics oflow speed axial fans of the arbitrary vortex flow type has been developed.The model is based on a blade-element principle, whereby therotor is divided into a number of annular streamtubes.For each of these streamtubes relations...... for velocity, pressure andradial position are derived from the conservationlaws for mass, tangential momentum and energy.The resulting system of equations is non-linear and, dueto mass conservation and pressure equilibrium far downstream of the rotor,strongly coupled.The equations are solved using the Newton...

  14. Single Band Helical Antenna in Axial Mode

    Directory of Open Access Journals (Sweden)

    Parminder Singh

    2012-11-01

    Full Text Available Helical antennas have been widely used in a various useful applications, due to their low weight and low profile conformability, easy and cheap realization.Radiation properties of this antenna are examined both theoretically and experimentally. In this paper, an attempt has been made to investigate new helical antenna structure for Applications. CST MWS Software is used for the simulation and design calculations of the helical antennas. The axial ratio, return loss, VSWR, Directivity, gain, radiation pattern is evaluated. Using CST MWS simulation software proposed antenna is designed/simulated and optimized. The antenna exhibits a single band from 0 GHz to 3 GHz for GPS and several satellite applications

  15. Tunable axial potentials for atom chip waveguides

    CERN Document Server

    Stickney, James A; Imhof, Eric; Kroese, Bethany R; Crow, Jonathon A R; Olson, Spencer E; Squires, Matthew B

    2014-01-01

    We present a method for generating algebraically precise magnetic potentials along the axis of a cold atom waveguide near the surface of an atom chip. With a single chip design consisting of several wire pairs, various axial potentials can be created, including double wells, triple wells, and pure harmonic traps with suppression of higher order terms. We characterize the error along a harmonic trap between the expected algebraic form and magnetic field simulations and find excel- lent agreement, particularly at small displacements from the trap center. Finally, we demonstrate experimental control over the bottom fields of an asymmetric double well potential.

  16. Cervical Spine Axial Rotation Goniometer Design

    Directory of Open Access Journals (Sweden)

    Emin Ulaş Erdem

    2012-06-01

    Full Text Available To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera. With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measurement of "joint position sense" which is recently has rising interest in researches can be made practically with this goniometer.

  17. Aerodynamics of Advanced Axial-Flow Turbomachinery.

    Science.gov (United States)

    1980-11-30

    cementing in place short segments of lb ga. (1.2 mm I.D.) hypodermic tubing in drillud holes carefully aligned normal to the sidewall profile at the...PRESSURE I REFERENCE SCANPREF I I SYSTEM 0YTE NECKED- PRF NEEDLE VALVE PE PRRSSUE TRANSDUCER AMPLIF IER] POSITIONER TEMPERATURES I STO BE READ I...Compressors. U.S. NASA SP-36. 1965. 23. Hearsey, R. M. A Revised Computer Program for Axial Compressor Design Volume 1: Theory , Descriptions and User’s

  18. Composite Axial Flow Propulsor for Small Aircraft

    OpenAIRE

    2005-01-01

    This work focuses on the design of an axial flow ducted fan driven by a reciprocating engine. The solution minimizes the turbulization of the flow around the aircraft. The fan has a rotor - stator configuration. Due to the need for low weight of the fan, a carbon/epoxy composite material was chosen for the blades and the driving shaft.The fan is designed for optimal isentropic efficiency and free vortex flow. A stress analysis of the rotor blade was performed using the Finite Element  Method....

  19. High-resolution imaging of biological tissue with full-field optical coherence tomography

    Science.gov (United States)

    Zhu, Yue; Gao, Wanrong

    2015-03-01

    A new full-field optical coherence tomography system with high-resolution has been developed for imaging of cells and tissues. Compared with other FF-OCT (Full-field optical coherence tomography, FF-OCT) systems illuminated with optical fiber bundle, the improved Köhler illumination arrangement with a halogen lamp was used in the proposed FF-OCT system. High numerical aperture microscopic objectives were used for imaging and a piezoelectric ceramic transducer (PZT) was used for phase-shifting. En-face tomographic images can be obtained by applying the five-step phase-shifting algorithm to a series of interferometric images which are recorded by a smart camera. Three-dimensional images can be generated from these tomographic images. Imaging of the chip of Intel Pentium 4 processor demonstrated the ultrahigh resolution of the system (lateral resolution is 0.8μm ), which approaches the theoretical resolution 0.7 μm× 0.5 μm (lateral × axial). En-face images of cells of onion show an excellent performance of the system in generating en-face images of biological tissues. Then, unstained pig stomach was imaged as a tissue and gastric pits could be easily recognized using FF-OCT system. Our study provides evidence for the potential ability of FFOCT in identifying gastric pits from pig stomach tissue. Finally, label-free and unstained ex vivo human liver tissues from both normal and tumor were imaged with this FFOCT system. The results show that the setup has the potential for medical diagnosis applications such liver cancer diagnosis.

  20. Ultrahigh resolution optical coherence tomography with femtosecond Ti:sapphire laser and photonic crystal fiber

    Institute of Scientific and Technical Information of China (English)

    XUE Ping; James G FUJIMOTO

    2008-01-01

    Optical coherence tomography (OCT) with ultrahigh axial resolution was achieved by the super-contin- uum generated by coupling femtosecond pulses from a commercial Ti :sapphire laser into an air-silica microstructure fiber. The visible spectrum of the super-continuum from 450 to 700 nm centered at 540 nm can be generated. A free-space axial OCT resolution of 0.64 IJm was achieved. The sensitivity of OCT system was 108 dB with incident light power 3 mW at sample, only 7dB below the theoretical limit. Subcellular OCT imaging was also demonstrated, showing great potential for biomedical application.

  1. Adaptive optics optical coherence tomography for retina imaging

    Institute of Scientific and Technical Information of China (English)

    Guohua Shi; Yun Dai; Ling Wang; Zhihua Ding; Xuejun Rao; Yudong Zhang

    2008-01-01

    When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 frames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented.

  2. Limited Angle Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Kyung; Cho, Min Kook; Kim, Seong Sik [Pusan National University, Busan (Korea, Republic of)

    2007-07-01

    In computed tomography (CT), many situations are restricted to obtain enough number of projections or views to avoid artifacts such as streaking and geometrical distortion in the reconstructed images. Speed of motion of an object to be imaged can limit the number of views. Cardiovascular imaging is a representative example. Size of an object can also limit the complete traverse motion or geometrical complexity can obscure to be imaged at certain range of angles. These situations are frequently met in industrial nondestructive testing and evaluation. Dental CT also suffers from similar situation because cervical spine causes less x-ray penetration from some directions such that the available information is not sufficient for standard reconstruction algorithms. The limited angle tomography is now greatly paid attention as a new genre in medical and industrial imaging, popularly known as digital tomosynthesis. In this study, we introduce a modified filtered backprojection method in limited angle tomography and demonstrate its application for the dental imaging.

  3. 4D Electron Tomography

    Science.gov (United States)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  4. Experimental adaptive process tomography

    Science.gov (United States)

    Pogorelov, I. A.; Struchalin, G. I.; Straupe, S. S.; Radchenko, I. V.; Kravtsov, K. S.; Kulik, S. P.

    2017-01-01

    Adaptive measurements were recently shown to significantly improve the performance of quantum state tomography. Utilizing information about the system for the online choice of optimal measurements allows one to reach the ultimate bounds of precision for state reconstruction. In this article we generalize an adaptive Bayesian approach to the case of process tomography and experimentally show its superiority in the task of learning unknown quantum operations. Our experiments with photonic polarization qubits cover all types of single-qubit channels. We also discuss instrumental errors and the criteria for evaluation of the ultimate achievable precision in an experiment. It turns out that adaptive tomography provides a lower noise floor in the presence of strong technical noise.

  5. Ocean acoustic reverberation tomography.

    Science.gov (United States)

    Dunn, Robert A

    2015-12-01

    Seismic wide-angle imaging using ship-towed acoustic sources and networks of ocean bottom seismographs is a common technique for exploring earth structure beneath the oceans. In these studies, the recorded data are dominated by acoustic waves propagating as reverberations in the water column. For surveys with a small receiver spacing (e.g., ocean acoustic reverberation tomography, is developed that uses the travel times of direct and reflected waves to image ocean acoustic structure. Reverberation tomography offers an alternative approach for determining the structure of the oceans and advancing the understanding of ocean heat content and mixing processes. The technique has the potential for revealing small-scale ocean thermal structure over the entire vertical height of the water column and along long survey profiles or across three-dimensional volumes of the ocean. For realistic experimental geometries and data noise levels, the method can produce images of ocean sound speed on a smaller scale than traditional acoustic tomography.

  6. Practical Bayesian Tomography

    CERN Document Server

    Granade, Christopher; Cory, D G

    2015-01-01

    In recent years, Bayesian methods have been proposed as a solution to a wide range of issues in quantum state and process tomography. State-of- the-art Bayesian tomography solutions suffer from three problems: numerical intractability, a lack of informative prior distributions, and an inability to track time-dependent processes. Here, we solve all three problems. First, we use modern statistical methods, as pioneered by Husz\\'ar and Houlsby and by Ferrie, to make Bayesian tomography numerically tractable. Our approach allows for practical computation of Bayesian point and region estimators for quantum states and channels. Second, we propose the first informative priors on quantum states and channels. Finally, we develop a method that allows online tracking of time-dependent states and estimates the drift and diffusion processes affecting a state. We provide source code and animated visual examples for our methods.

  7. Stall inception in a high-speed axial compressor

    Science.gov (United States)

    Cameron, Joshua David

    A research program designed to provide understanding of the fluid dynamic mechanisms that lead to rotating stall in the Notre Dame Stage 01 high-speed axial compressor is described. The stalling behavior of this compressor was studied with unsteady casing pressure measurements from a circumferentially spaced array of sensors. In addition, over rotor casing surface streak measurements were performed to investigate the time-averaged end-wall flow near the rotor at operating points near stall. Several investigative tools were applied to the analysis and interpretation of the unsteady casing pressure data. Traditional methods such as visual inspection, spatial Fourier decomposition, traveling wave energy and wavelet analysis were shown to be insufficient to characterize the pre-stall and stall inception behavior of the compressor. A new technique based on a windowed two-point correlation between adjacent sensors was developed and demonstrated to provide spatial and temporal resolution of both pre-stall and stall inception behavior. The spatial correlation technique was then applied to the analysis of stall inception data from experiments with asymmetric tip clearance. The non-uniform tip clearance was produced using the magnetic bearings which levitate the rotor shaft of the Notre Dame Transonic Axial Compressor facility. Both steady rotor centerline offset and rotor whirl were investigated. The results of these experiments, along with the surface streak measurements, provide evidence in support of recent computational observations (found in the literature) that predict that short length scale stall inception is related to specific features of the rotor tip clearance flow.

  8. Axial vascularization of a large volume calcium phosphate ceramic bone substitute in the sheep AV loop model.

    Science.gov (United States)

    Beier, Justus P; Horch, Raymund E; Hess, Andreas; Arkudas, Andreas; Heinrich, Johanna; Loew, Johanna; Gulle, Heinz; Polykandriotis, Elias; Bleiziffer, Oliver; Kneser, Ulrich

    2010-03-01

    Vascularization still remains an obstacle to engineering of bone tissue with clinically relevant dimensions. Our aim was to induce axial vascularization in a large volume of a clinically approved biphasic calcium phosphate ceramic by transferring the arteriovenous (AV) loop approach to a large animal model. HA/beta-TCP granula were mixed with fibrin gel for a total volume of 16 cm(3), followed by incorporation into an isolation chamber together with an AV loop. The chambers were implanted into the groins of merino sheep and the development of vascularization was monitored by sequential non-invasive magnetic resonance imaging (MRI). The chambers were explanted after 6 and 12 weeks, the pedicle was perfused with contrast agent and specimens were subjected to micro-computed tomography (micro-CT) scan and histological analysis. Sequential MRI demonstrated a significantly increased perfusion in the HA/beta-TCP matrices over time. Micro-CT scans and histology confirmed successful axial vascularization of HA/beta-TCP constructs. This study demonstrates, for the first time, successful axial vascularization of a clinically approved bone substitute with a significant volume in a large animal model by means of a microsurgically created AV loop, thus paving the way for the first microsurgical transplantation of a tissue-engineered, axially vascularized bone with clinically relevant dimensions.

  9. Single Rod Vibration in Axial Flow

    Science.gov (United States)

    Weichselbaum, Noah; Wang, Shengfu; Bardet, Philippe

    2013-11-01

    Fluid structure interaction of a single rod in axial flow is a coupled dynamical system present in many application including nuclear reactors, steam generators, and towed antenna arrays. Fluid-structure response can be quantified thanks to detailed experimental data where both structure and fluid responses are recorded. Such datum deepen understanding of the physics inherent to the system and provide high-dimensionality quantitative measurements to validate coupled structural and CFD codes with various level of complexity. In this work, single rods fixed on both ends in a concentric pipe, are subjected to an axial flow with Reynolds number based on hydraulic diameter of Re =4000. Rods of varying material stiffness and diameter are utilized in the experiment resulting in a range of dimensionless U between 0.5 and 1, where U = (ρA/EI)1/2uL. Experimental measurements of the velocity field around the rod are taken with PIV from time-resolved Nd:YLF laser and a high speed CMOS camera. Three-dimensional and temporal vibration and deflection of the rod is recorded with shadowgraphy utilizing two sets of pulsed high power LED and dedicated CMOS camera. Through integration of these two diagnostics, it is possible to reconstruct the full FSI domain providing unique validation data.

  10. Axial residual stresses in boron fibers

    Science.gov (United States)

    Behrendt, D. R.

    1978-01-01

    A method of measuring axial residual stresses in boron fibers is presented. With this method, the axial residual stress distribution as a function of radius is determined from the fiber surface to the core including the average residual stress in the core. Such measurements on boron on tungsten (B/W) fibers show that the residual stresses for 102, 142, 203, and 366 micron diam fibers are similar, being compressive at the surface and changing monotonically to a region of tensile stress within the boron. At approximately 25% of the original radius, the stress reaches a maximum tensile stress of about 860 MN sq m and then decreases to a compressive stress near the tungsten boride core. Data are presented for 203-micron diam B/W fibers that show annealing above 900 C reduces the residual stresses. A comparison between 102-micron diam B/W and boron on carbon (B/C) show that the residual stresses are similar in the outer regions of the fibers, but that large differences near and in the core are observed. Fracture of boron fibers is discussed.

  11. Atom Probe Tomography 2012

    Science.gov (United States)

    Kelly, Thomas F.; Larson, David J.

    2012-08-01

    In the world of tomographic imaging, atom probe tomography (APT) occupies the high-spatial-resolution end of the spectrum. It is highly complementary to electron tomography and is applicable to a wide range of materials. The current state of APT is reviewed. Emphasis is placed on applications and data analysis as they apply to many fields of research and development including metals, semiconductors, ceramics, and organic materials. We also provide a brief review of the history and the instrumentation associated with APT and an assessment of the existing challenges in the field.

  12. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Muehllehner, Gerd; Karp, Joel S [Department of Radiology, University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104 (United States)

    2006-07-07

    The developments in positron emission tomography (PET) are reviewed with an emphasis on instrumentation for clinical PET imaging. After a brief summary of positron imaging before the advent of computed tomography, various improvements are highlighted including the move from PET scanners with septa to fully 3D scanners, changes in the preferred scintillators, efforts to improve the energy discrimination, and improvements in attenuation correction. Time-of-flight PET imaging is given special attention due to the recent revival of this technique, which promises significant improvement. Besides technical instrumentation efforts, other factors which influenced the acceptance of clinical PET are also discussed. (review)

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  14. Coronary Computed Tomography Angiography (CTA)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Coronary Computed Tomography Angiography (CCTA) Coronary computed tomography angiography (CCTA) ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  15. Computer processing of tomography data

    OpenAIRE

    Konečný, Jan

    2011-01-01

    Computer processing of tomography data Tomographs are one of the most important diagnostic devices, which are used in every hospital nowadays; they have already been so for a considerable period of time. The different types of tomographs and the processing of tomographic data and imaging of these data are the subject of this thesis. I have described the four most common types of tomography: X-ray Computed Tomography, Magnetic Resonance Imaging, Positron Emission Tomography and Single Photon E...

  16. The ASAS Criteria for Axial Spondyloarthritis: Strengths, Weaknesses, and Proposals for a Way Forward.

    Science.gov (United States)

    van der Linden, Sjef; Akkoc, Nurullah; Brown, Matthew A; Robinson, Philip C; Khan, Muhammad A

    2015-09-01

    Classification criteria should facilitate selection of similar patients for clinical and epidemiologic studies, therapeutic trials, and research on etiopathogenesis to enable comparison of results across studies from different centers. We critically appraise the validity and performance of the Assessment of SpondyloArthritis international Society (ASAS) classification criteria for axial spondyloarthritis (axSpA). It is still debatable whether all patients fulfilling these criteria should be considered as having true axSpA. Patients with radiographically evident disease by the ASAS criteria are not necessarily identical with ankylosing spondylitis (AS) as classified by the modified New York criteria. The complex multi-arm selection design of the ASAS criteria induces considerable heterogeneity among patients so classified, and applying them in settings with a low prevalence of axial spondyloarthritis (SpA) greatly increases the proportion of subjects falsely classified as suffering from axial SpA. One of the unmet needs in non-radiographic form of axial SpA is to have reliable markers that can identify individuals at risk for progression to AS and thereby facilitate early intervention trials designed to prevent such progression. We suggest needed improvements of the ASAS criteria for axSpA, as all criteria sets should be regarded as dynamic concepts open to modifications or updates as our knowledge advances.

  17. Study on the Axial Dispersion of Liquid in Column Flotation

    Institute of Scientific and Technical Information of China (English)

    周鵾; 曾爱武; 高长宝; 余国琮

    2003-01-01

    An experimental study on the axial dispersion of liquid was carried out in a 0.382-m-ID flotation column packed with different structured packings or free of packings. The correlations of axial Peclet numbers with the liquid and gas superficial Reynolds numbers were developed for various packings. Among the packings tested, it is found that in the column packed with 250Y or 350Y packings the axial dispersion is the lowest. The addition of frother can decrease the axial dispersion. By the simulation analysis of the one-dimension dispersion model of packed flotation column, it is found that small axial dispersion, high collection rate constant and low axial liquid velocity can increase the collection zone recovery.

  18. A technique to determine a desired preparation axial inclination.

    Science.gov (United States)

    Parker, M Harry; Ivanhoe, John R; Blalock, John S; Frazier, Kevin B; Plummer, Kevin D

    2003-10-01

    The guidelines recommended in the literature for the convergence angle of a crown preparation vary from 3 to 24 degrees. There is a lack of guidelines on techniques to achieve a specific axial inclination. The purpose of this article was to present a practical technique, with a diamond rotary cutting instrument of known axial inclination, to determine the diamond rotary cutting instrument angulations required to achieve the desired axial inclination of a preparation.

  19. Design and Test of a Transonic Axial Splittered Rotor

    Science.gov (United States)

    2015-06-15

    geometric rendering and analysis of a transonic axial compressor rotor with splitter blades. Predictive numerical simulations were conducted and...ANSYS-CFX) for the geometric rendering and analysis of a transonic axial compressor rotor with splitter blades. Predictive numerical simulations were...that uses commercial-off-the-shelf software ( MATLAB , SolidWorks, and ANSYS-CFX) for the geometric rendering and analysis of a transonic axial

  20. Rotordynamics of Turbine Labyrinth Seals with Rotor Axial Shifting

    OpenAIRE

    Jinxiang Xi; Rhode, David L.

    2006-01-01

    Rotors in high-performance steam turbines experience a significant axial shifting during starting and stopping processes due to thermal expansion, for example. This axial shifting could significantly alter the flow pattern and the flow-induced rotordynamic forces in labyrinth seals, which in turn, can considerably affect the rotor-seal system performance. This paper investigates the influence of the rotor axial shifting on leakage rate as well as rotordynamic forces in hi...

  1. Underwater Acoustic Tomography

    Directory of Open Access Journals (Sweden)

    V. K. Aatre

    1985-04-01

    Full Text Available Ever since the CAT scanner technique for medical imaging was introduced, the fields of tomography and image reconstruction from slices have been gaining in popularity. Towards the end of the last decade, the application of tomographic method to large scale ocean monitoring was explored. This paper surveys the application of tomographic methods to ocean monitoring and surveiIlance.

  2. Holography and tomography

    Energy Technology Data Exchange (ETDEWEB)

    Howells, M. [Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography.

  3. Dental Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Kun-Feng Lin

    2013-07-01

    Full Text Available This review paper describes the applications of dental optical coherence tomography (OCT in oral tissue images, caries, periodontal disease and oral cancer. The background of OCT, including basic theory, system setup, light sources, spatial resolution and system limitations, is provided. The comparisons between OCT and other clinical oral diagnostic methods are also discussed.

  4. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Andersen, Peter E.

    2015-01-01

    Optical coherence tomography (OCT) is a noninvasive imaging technique that provides real-time two- and three-dimensional images of scattering samples with micrometer resolution. Mapping the local reflectivity, OCT visualizes the morphology of the sample, in real time or at video rate. In addition...

  5. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  6. Casimir Energy in the Axial Gauge

    CERN Document Server

    Esposito, G; Kirsten, K; Esposito, Giampiero; Kamenshchik, Alexander Yu.; Kirsten, Klaus

    2000-01-01

    The zero-point energy of a conducting spherical shell is studied by imposing the axial gauge via path-integral methods, with boundary conditions on the electromagnetic potential and ghost fields. The coupled modes are then found to be the temporal and longitudinal modes for the Maxwell field. The resulting system can be decoupled by studying a fourth-order differential equation with boundary conditions on longitudinal modes and their second derivatives. The exact solution of such equation is found by using a Green-function method, and is obtained from Bessel functions and definite integrals involving Bessel functions. Complete agreement with a previous path-integral analysis in the Lorenz gauge, and with Boyer's value, is proved in detail.

  7. The Axial Part Phrase in Japanese

    Directory of Open Access Journals (Sweden)

    Kaori Takamine

    2007-01-01

    Full Text Available In this paper, I investigate the categorial status of spatial terms in locative/directional expressions in Japanese. I will show that a certain class of spatial terms have a distinct categorial status from both regular postpositions and nouns. On one hand, syntactic diagnostics such as doubling, coordination by to, and co-occurrence with demonstratives indicate that these spatial terms belong to a nominal category rather than to a postpositional category. On the other hand, the fact that these spatial terms are modified by range modifiers indicates that they are more similar to regular postpositions than to nouns. On the basis of these diagnostics, I will argue that spatial terms in Japanese need to be assigned a new category Axial Part Phrase which is proposed by Svenonius 2006.

  8. Composite Axial Flow Propulsor for Small Aircraft

    Directory of Open Access Journals (Sweden)

    R. Poul

    2005-01-01

    Full Text Available This work focuses on the design of an axial flow ducted fan driven by a reciprocating engine. The solution minimizes the turbulization of the flow around the aircraft. The fan has a rotor - stator configuration. Due to the need for low weight of the fan, a carbon/epoxy composite material was chosen for the blades and the driving shaft.The fan is designed for optimal isentropic efficiency and free vortex flow. A stress analysis of the rotor blade was performed using the Finite Element  Method. The skin of the blade is calculated as a laminate and the foam core as a solid. A static and dynamic analysis were made. The RTM technology is compared with other technologies and is described in detail. 

  9. Aerodynamics of advanced axial-flow turbomachinery

    Science.gov (United States)

    Serovy, G. K.; Kavanagh, P.; Kiishi, T. H.

    1980-01-01

    A multi-task research program on aerodynamic problems in advanced axial-flow turbomachine configurations was carried out at Iowa State University. The elements of this program were intended to contribute directly to the improvement of compressor, fan, and turbine design methods. Experimental efforts in intra-passage flow pattern measurements, unsteady blade row interaction, and control of secondary flow are included, along with computational work on inviscid-viscous interaction blade passage flow techniques. This final report summarizes the results of this program and indicates directions which might be taken in following up these results in future work. In a separate task a study was made of existing turbomachinery research programs and facilities in universities located in the United States. Some potentially significant research topics are discussed which might be successfully attacked in the university atmosphere.

  10. Aerodynamic modelling and optimization of axial fans

    Energy Technology Data Exchange (ETDEWEB)

    Noertoft Soerensen, Dan

    1998-01-01

    A numerically efficient mathematical model for the aerodynamics of low speed axial fans of the arbitrary vortex flow type has been developed. The model is based on a blade-element principle, whereby the rotor is divided into a number of annular stream tubes. For each of these stream tubes relations for velocity, pressure and radial position are derived from the conservation laws for mass, tangential momentum and energy. The equations are solved using the Newton-Raphson methods, and solutions converged to machine accuracy are found at small computing costs. The model has been validated against published measurements on various fan configurations, comprising two rotor-only fan stages, a counter-rotating fan unit and a stator-rotor stator stage. Comparisons of local and integrated properties show that the computed results agree well with the measurements. Optimizations have been performed to maximize the mean value of fan efficiency in a design interval of flow rates, thus designing a fan which operates well over a range of different flow conditions. The optimization scheme was used to investigate the dependence of maximum efficiency on 1: the number of blades, 2: the width of the design interval and 3: the hub radius. The degree of freedom in the choice of design variable and constraints, combined with the design interval concept, provides a valuable design-tool for axial fans. To further investigate the use of design optimization, a model for the vortex shedding noise from the trailing edge of the blades has been incorporated into the optimization scheme. The noise emission from the blades was minimized in a flow rate design point. Optimizations were performed to investigate the dependence of the noise on 1: the number of blades, 2: a constraint imposed on efficiency and 3: the hub radius. The investigations showed, that a significant reduction of noise could be achieved, at the expense of a small reduction in fan efficiency. (EG) 66 refs.

  11. Coexistence of axial spondyloarthritis and thromboangiitis obliterans in a young woman

    Directory of Open Access Journals (Sweden)

    G. Lopalco

    2015-06-01

    Full Text Available A peculiar coexistence of axial spondyloarthritis and ischemia of the feet and the fourth finger of the left hand in a young woman, who was a heavy smoker, is discussed in this report. This picture was considered within the context of thromboangiitis obliterans. Positivity of anti-nuclear antibodies and mild elevation of inflammatory parameters were noted. Computed tomography angiograms of upper and lower limbs showed luminal narrowing and occlusion of the left humeral, left anterior/posterior tibial and right anterior tibial arteries. Daily iloprost perfusions were started, and smoking cessation was strongly recommended. Coldness and rest pain in the distal extremities improved within a few weeks. The possibility that spondyloarthritis might precede the clinical picture of thromboangiitis obliterans should be considered in heavy smokers.

  12. Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Segars, W. P., E-mail: paul.segars@duke.edu; Rybicki, K.; Norris, Hannah; Samei, E. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Frush, D. [Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States)

    2014-12-15

    Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r{sup 2} = 0.382, mean r{sup 2} = 0.236). Similar trends were found for organ midpoint versus height (max r{sup 2} = 0.439, mean r{sup 2} = 0.200) and for organ volume versus height (max r{sup 2} = 0.410, mean r{sup 2} = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r{sup 2}-values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r{sup 2} = 0.842, mean r{sup 2} = 0.790; max r{sup 2} = 0.949, mean r{sup 2} = 0.894; and max r{sup 2} = 0.870, mean r{sup 2} = 0.847, respectively). Moderate linear correlations were also observed for organ axial width

  13. Update on the American College of Rheumatology/Spondyloarthritis Research and Treatment Network/Spondylitis Association of America axial spondyloarhtritis treatment guidelines project.

    Science.gov (United States)

    Ward, Michael M

    2014-06-01

    The American College of Rheumatology, the Spondyloarthritis Research and Treatment Network, and the Spondylitis Association of America have begun collaborating on a project to develop treatment guidelines for axial spondyloarthritis. The project will use the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) method, which is based on systematic literature reviews and quantitative evidence summaries, to develop treatment recommendations for the use of pharmacological interventions, rehabilitation, surgery, preventive care, and disease monitoring in patients with ankylosing spondylitis and axial spondyloarthritis.

  14. Direct coronal computed tomography of the lumbar spine: A new technical approach in supine position

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Uske, A.; Mansouri, B.

    1986-11-01

    Computed tomography (CT) was carried out on 46 subjects with L5-S1 disk hernia. All the patients had a L5-S1 angle equal or greater than 40 degrees. Coronal sections of the disk were obtained with a rostral angulation of the gantry, having placed the lumbar spin in a hyperlordotic position. Results are discussed and compared with those obtained from para-axial transverse sections and multidirectional reformated images.

  15. Morphometric study of maxillary sinus by computed tomography. Assessment of sinus floor bone reconstruction

    OpenAIRE

    2012-01-01

    Rehabilitation with dental implants in posterior maxilla is difficult because of the presence of maxillary sinus with anatomical variations. The aim of this research was to evaluate the sinus volume to install one or more implants without invading the sinus membrane. Forty (40) maxillary sinuses were evaluated in 22 skulls by computed tomography measuring in the axial, coronal and sagittal slice. The sinus were classified according to the remaining alveolar bone and a dental implant in the pl...

  16. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  17. Quantitative analysis of cone photoreceptor distribution and its relationship with axial length, age, and early age-related macular degeneration.

    Directory of Open Access Journals (Sweden)

    Ryo Obata

    Full Text Available PURPOSE: It has not been clarified whether early age-related macular degeneration (AMD is associated with cone photoreceptor distribution. We used adaptive optics fundus camera to examine cone photoreceptors in the macular area of aged patients and quantitatively analyzed its relationship between the presence of early AMD and cone distribution. METHODS: Sixty cases aged 50 or older were studied. The eyes were examined with funduscopy and spectral-domain optical coherence tomography to exclude the eyes with any abnormalities at two sites of measurement, 2° superior and 5° temporal to the fovea. High-resolution retinal images with cone photoreceptor mosaic were obtained with adaptive optics fundus camera (rtx1, Imagine Eyes, France. After adjusting for axial length, cone packing density was calculated and the relationship with age, axial length, or severity of early AMD based on the age-related eye disease study (AREDS classification was analyzed. RESULTS: Patient's age ranged from 50 to 77, and axial length from 21.7 to 27.5 mm. Mean density in metric units and that in angular units were 24,900 cells/mm2, 2,170 cells/deg2 at 2° superior, and 18,500 cells/mm2, 1,570 cels/deg2 at 5° temporal, respectively. Axial length was significantly correlated with the density calculated in metric units, but not with that in angular units. Age was significantly correlated with the density both in metric and angular units at 2° superior. There was no significant difference in the density in metric and angular units between the eyes with AREDS category one and those with categories two or three. CONCLUSION: Axial length and age were significantly correlated with parafoveal cone photoreceptor distribution. The results do not support that early AMD might influence cone photoreceptor density in the area without drusen or pigment abnormalities.

  18. Correction of distortions in optical coherence tomography imaging of the eye

    Energy Technology Data Exchange (ETDEWEB)

    Podoleanu, Adrian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Charalambous, Ismini [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Plesea, Lucian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Dogariu, Aristide [School of Optics, CREOL, University of Central Florida, Orlando, FL (United States); Rosen, Richard [Advanced Retinal Imaging Center, New York Eye and Ear Infirmary, NY (United States)

    2004-04-07

    Optical coherence tomography (OCT) images are affected by artefacts. These artefacts are the result of different factors such as refraction, curvature of the intermediate layers up to the depth of interest and the scanning procedure. The effect of such errors is different, depending on the way the image is acquired, either en-face or longitudinal OCT. We quantify the distortions by evaluating a lateral and an axial error. These measure the lateral and axial deviations of each image point from the object point inside the tissue. We show that the axial distortion can be larger than the achievable depth resolution in modern OCT systems. We have investigated these errors in imaging different tissue: cornea and retina in vivo and an intraocular lens in vitro.

  19. Improved axial position detection in optical tweezers measurements

    DEFF Research Database (Denmark)

    Dreyer, Jakob Kisbye; Berg-Sørensen, Kirstine; Oddershede, Lene

    2004-01-01

    We investigate the axial position detection of a trapped microsphere in an optical trap by using a quadrant photodiode. By replacing the photodiode with a CCD camera, we obtain detailed information on the light scattered by the microsphere. The correlation of the interference pattern with the axial...

  20. Through flow analysis within axial flow turbomachinery blade rows

    Science.gov (United States)

    Girigoswami, H.

    1986-09-01

    Using Katsanis' Through Flow Code, inviscid flow through an axial flow compressor rotor blade as well as flow through inlet guide vanes are analyzed and the computed parameters such as meridional velocity distribution, axial velocity distribution along radial lines, and velocity distribution over blade surfaces are presented.

  1. Test Setup for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test setup for testing axially static and cyclic loaded piles in sand is described in the following. The purpose for the tests is to examine the tensile capacity of axially loaded piles in dense fully saturated sand. The pile dimensions are chosen to resemble full scale dimension of piles used...... in offshore pile foundations today....

  2. An Unbroken Axial-Vector Current Conservation Law

    Science.gov (United States)

    Sharafiddinov, Rasulkhozha S.

    2016-04-01

    The mass, energy and momentum of the neutrino of a true flavor have an axial-vector nature. As a consequence, the left-handed truly neutral neutrino in an axial-vector field of emission can be converted into a right-handed one and vice versa. This predicts the unidenticality of masses, energies and momenta of neutrinos of the different components. Recognizing such a difference in masses, energies, momenta and accepting that the left-handed axial-vector neutrino and the right-handed antineutrino of true neutrality refer to long-lived C-odd leptons, and the right-handed truly neutral neutrino and the left-handed axial-vector antineutrino are of short-lived fermions of C-oddity, we would write a new CP-even Dirac equation taking into account the flavor symmetrical axial-vector mass, energy and momentum matrices. Their presence explains the spontaneous mirror symmetry violation, confirming that an axial-vector current conservation law has never violated. They reflect the availability of a mirror Minkowski space in which a neutrino is characterized by left as well as by right space-time coordinates. Therefore, it is not surprising that whatever the main purposes experiments about a quasielastic axial-vector mass say in favor of an axial-vector mirror Minkowski space-time.

  3. A new approach to radial and axial gauges

    Science.gov (United States)

    Weigert, Heribert; Heinz, Ulrich

    1992-03-01

    We develop a new path integral formulation of QCD in radial and axial gauges. This formalism yields free propagators which are free of gauge poles. We find that radial gauges are ghost free. In axial gauges ghosts cannot generally be excluded from the formalism due to the need to fix the residual gauge freedom.

  4. Metastatic disease of the brain: extra-axial metastases (skull, dura, leptomeningeal) and tumour spread

    Energy Technology Data Exchange (ETDEWEB)

    Maroldi, Roberto; Ambrosi, Claudia; Farina, Davide [University of Brescia, Department of Radiology, Brescia, BS (Italy)

    2005-03-01

    Extra-axial intracranial metastases may arise through several situations. Hematogenous spread to the meninges is the most frequent cause. Direct extension from contiguous extra-cranial neoplasms, secondary invasion of the meninges by calvarium and skull base metastases, and migration along perineural or perivascular structures are less common. Leptomeningeal invasion gives rise to tumour cell dissemination by the cerebrospinal fluid (CSF), eventually leading to neoplastic coating of brain surfaces. Contrast-enhanced magnetic resonance (MR) imaging is complementary to CSF examinations and can be invaluable, detecting up to 50% of false-negative lumbar punctures. MR findings range from diffuse linear leptomeningeal enhancement to multiple enhancing extra-axial nodules, obstructive communicating and non-communicating hydrocephalus. Both calvarial and epidural metastases infrequently transgress the dura, which acts as a barrier against tumour spread. Radionuclide bone studies are still a valuable screening test to detect bone metastases. With computed tomography (CT) and MR, bone metastases extending intracranially and primary dural metastases show the characteristic biconvex shape, usually associated with brain displacement away from the inner table. Although CT is better in detecting skull base erosion, MR is more sensitive and provides more detailed information about dural involvement. Perineural and perivascular spread from head and neck neoplasms require thin-section contrast-enhanced MR. (orig.)

  5. Simultaneous refraction measurement and OCT axial biometry of the eye during accommodation (Conference Presentation)

    Science.gov (United States)

    De Freitas, Carolina; Hernandez, Victor M.; Ruggeri, Marco; Durkee, Heather A.; Williams, Siobhan; Gregori, Giovanni; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie

    2016-03-01

    The purpose of this project is to design and evaluate a system that will enable objective assessment of the optical accommodative response in real-time while acquiring axial biometric information. The system combines three sub-systems which were integrated and mounted on a joystick x-y-z adjustable modified slit-lamp base to facilitate alignment and data acquisition: (1) a Shack-Hartmann wavefront sensor for dynamic refraction measurement, provided software calculates sphere, cylinder and axis values, (2) an extended-depth Optical Coherence Tomography (OCT) system using an optical switch records high-resolution cross-sectional images across the length of the eye, from which, dynamic axial biometry (corneal thickness, anterior chamber depth, crystalline lens thickness and vitreous depth) can be extracted, and (3) a modified dual-channel accommodation stimulus unit based on the Badal optometer for providing a step change in accommodative stimulus. The prototypal system is capable of taking simultaneous measurements of both the optical and the mechanical response of lens accommodation. These measurements can provide insight into correlating changes in lens shape with changes in lens power and ocular refraction and ultimately provide a more comprehensive understanding of accommodation, presbyopia and an objective assessment of presbyopia correction techniques.

  6. Optical Tomography in Combustion

    DEFF Research Database (Denmark)

    Evseev, Vadim

    spectral measurements at several line-of-sights with a view to applications for tomographic measurements on full-scale industrial combustion systems. The system was successfully applied on industrial scale for simultaneous fast exhaust gas temperature measurements in the three optical ports of the exhaust......D project, it was also important to investigate the spectral properties of major combustion species such as carbon dioxide and carbon monoxide in the infrared range at high temperatures to provide the theoretical background for the development of the optical tomography methods. The new software....... JQSRT 113 (2012) 2222, 10.1016/j.jqsrt.2012.07.015] included in the PhD thesis as an attachment. The knowledge and experience gained in the PhD project is the first important step towards introducing the advanced optical tomography methods of combustion diagnostics developed in the project to future...

  7. Mathematical Methods in Tomography

    CERN Document Server

    Louis, Alfred; Natterer, Frank

    1991-01-01

    The conference was devoted to the discussion of present and future techniques in medical imaging, including 3D x-ray CT, ultrasound and diffraction tomography, and biomagnetic ima- ging. The mathematical models, their theoretical aspects and the development of algorithms were treated. The proceedings contains surveys on reconstruction in inverse obstacle scat- tering, inversion in 3D, and constrained least squares pro- blems.Research papers include besides the mentioned imaging techniques presentations on image reconstruction in Hilbert spaces, singular value decompositions, 3D cone beam recon- struction, diffuse tomography, regularization of ill-posed problems, evaluation reconstruction algorithms and applica- tions in non-medical fields. Contents: Theoretical Aspects: J.Boman: Helgason' s support theorem for Radon transforms-a newproof and a generalization -P.Maass: Singular value de- compositions for Radon transforms- W.R.Madych: Image recon- struction in Hilbert space -R.G.Mukhometov: A problem of in- teg...

  8. Proton computed tomography

    Science.gov (United States)

    Bucciantonio, Martina; Sauli, Fabio

    2015-05-01

    Proton computed tomography (pCT) is a diagnostic method capable of in situ imaging the three-dimensional density distribution in a patient before irradiation with charged particle beams. Proposed long time ago, this technology has been developed by several groups, and may become an essential tool for advanced quality assessment in hadrontherapy. We describe the basic principles of the method, its performance and limitations as well as provide a summary of experimental systems and of results achieved.

  9. Transurethral Ultrasound Diffraction Tomography

    Science.gov (United States)

    2007-03-01

    results 15. SUBJECT TERMS acoustic inverse scattering, acoustic tomography, Lippmann- Schwinger Equation, conjugate gradient FFT, prostate imaging 16...any ultrasonic inverse scattering algo- rithm. These are: (1) efficient solutions of the Lippmann- Schwinger integral equation of scattering - the so...Fast and efficient codes for the solution of the Lippmann- Schwinger equation were written using CG-FFT. These were checked against ana- lytical benchmark

  10. Tutorial on photoacoustic tomography

    Science.gov (United States)

    Zhou, Yong; Yao, Junjie; Wang, Lihong V.

    2016-06-01

    Photoacoustic tomography (PAT) has become one of the fastest growing fields in biomedical optics. Unlike pure optical imaging, such as confocal microscopy and two-photon microscopy, PAT employs acoustic detection to image optical absorption contrast with high-resolution deep into scattering tissue. So far, PAT has been widely used for multiscale anatomical, functional, and molecular imaging of biological tissues. We focus on PAT's basic principles, major implementations, imaging contrasts, and recent applications.

  11. New classes of bi-axially symmetric solutions to four-dimensional Vasiliev higher spin gravity

    CERN Document Server

    Sundell, Per

    2016-01-01

    We present new infinite-dimensional spaces of bi-axially symmetric asymptotically anti-de Sitter solutions to four-dimensional Vasiliev higher spin gravity, obtained by modifications of the Ansatz used in arXiv:1107.1217, which gave rise to a Type-D solution space. The current Ansatz is based on internal semigroup algebras (without identity) generated by exponentials formed out of the bi-axial symmetry generators. After having switched on the vacuum gauge function, the resulting generalized Weyl tensor is given by the sum of two generalized Petrov type-D tensors, and the twistor space connections are smooth in twistor space over finite regions of spacetime. We provide evidence for that the linearized twistor space connection can be brought to Vasiliev gauge.

  12. On Stationary Axially Symmetric Solutions in Brans-Dicke Theory

    CERN Document Server

    Kirezli, Pınar

    2015-01-01

    Stationary axially symmetric Brans-Dicke-Maxwell solutions are re-examined in the framework of the Brans-Dicke theory. We see that, employing a particular parametrization of the standard axially symmetric metric simplifies the procedure of obtaining the Ernst equations for axially symmetric electro-vacuum space-times for this theory. This analysis also permit us to construct a two parameter extension in both Jordan and Einstein frames of an old solution generating technique frequently used to construct axially symmetric solutions for Brans-Dicke theory from a seed solution of General Relativity. As applications of this technique, several known and new solutions are constructed including a general axially symmetric BD-Maxwell solution of Plebanski-Demianski with vanishing cosmological constant, i.e. the Kinnersley solution and general magnetized Kerr-Newman type solutions. Some physical properties and circular motion of test particles for a particular subclass of Kinnersley solution, i.e. Kerr-Newman-NUT type ...

  13. Axial vibration analysis of nanocones based on nonlocal elasticity theory

    Institute of Scientific and Technical Information of China (English)

    Shu-Qi Guo; Shao-Pu Yang

    2012-01-01

    Carbon nanocones have quite fascinating electronic and structural properties,whose axial vibration is seldom investigated in previous studies.In this paper,based on a nonlocal elasticity theory,a nonuniform rod model is applied to investigate the small-scale effect and the nonuniform effect on axial vibration of nanocones.Using the modified Wentzel-Brillouin-Kramers (WBK) method,an asymptotic solution is obtained for the axial vibration of general nonuniform nanorods.Then,using similar procedure,the axial vibration of nanocones is analyzed for nonuniform parameters,mode number and nonlocal parameters.Explicit expressions are derived for mode frequencies of clamped-clamped and clamped-free boundary conditions.It is found that axial vibration frequencies are highly overestimated by the classical rod model because of ignorance of the effect of small length scale.

  14. Polychromatic diffraction contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    King, A., E-mail: king@synchrotron-soleil.fr [Synchrotron SOLEIL, Gif-sur-Yvette 91192 (France); Reischig, P. [Xnovo Technology ApS, 4600 Køge (Denmark); Department of Materials Science and Engineering, Delft University of Technology, Delft 2628 CD (Netherlands); Adrien, J. [MATEIS, INSA de Lyon, Villeurbanne 69621 (France); Peetermans, S. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Ludwig, W. [MATEIS, INSA de Lyon, Villeurbanne 69621 (France); European Synchrotron Radiation Facility, Grenoble 38043 (France)

    2014-11-15

    This tutorial review introduces the use of polychromatic radiation for 3D grain mapping using X-ray diffraction contrast tomography. The objective is to produce a 3D map of the grain shapes and orientations within a bulk, millimeter-sized polycrystalline sample. The use of polychromatic radiation enables the standard synchrotron X-ray technique to be applied in a wider range of contexts: 1) Using laboratory X-ray sources allows a much wider application of the diffraction contrast tomography technique. 2) Neutron sources allow large samples, or samples containing high Z elements to be studied. 3) Applied to synchrotron sources, smaller samples may be treated, or faster measurements may be possible. Challenges and particularities in the data acquisition and processing, and the limitations of the different variants, are discussed. - Highlights: • We present a tutorial review of polychromatic diffraction contrast tomography techniques. • The use of polychromatic radiation allows the standard synchrotron DCT technique to be extended to a range of other sources. • The characteristics and limitations of all variants of the techniques are derived, discussed and compared. • Examples using laboratory X-ray and cold neutron radiation are presented. • Suggestions for the future development of these techniques are presented.

  15. The Definition and Measurement of Axial Psoriatic Arthritis.

    Science.gov (United States)

    Lubrano, Ennio; Parsons, Wendy Joanne; Marchesoni, Antonio; Olivieri, Ignazio; D'Angelo, Salvatore; Cauli, Alberto; Caso, Francesco; Costa, Luisa; Scarpa, Raffaele; Brunese, Luca

    2015-11-01

    This review seeks to update the state of the art of axial psoriatic arthritis (axPsA). The definition and assessment of axPsA can be problematic because no agreement and no definitive data on this topic have been published, resulting in uncertainty as to the best approach to deal with these patients. A few recent scientific reports show new data on the possible coincidence of diffuse idiopathic skeletal hyperostosis and axPsA, as well as on the radiological assessment as measured with the validated instruments for axPsA. Moreover, the role of magnetic resonance imaging has also been evaluated for this intriguing subset. All data confirmed that radiological assessment is a useful tool to detect typical findings of axPsA, while other imaging techniques remain to be validated. Finally, there is no evidence to support treatment of axPsA with traditional disease-modifying antirheumatic drugs, while a "leap" to biologic agents is the only treatment after failure with nonsteroidal antiinflammatory drugs.

  16. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  17. Axial 3D region of interest reconstruction using weighted cone beam BPF/DBPF algorithm cascaded with adequately oriented orthogonal butterfly filtering

    Science.gov (United States)

    Tang, Shaojie; Tang, Xiangyang

    2016-03-01

    Axial cone beam (CB) computed tomography (CT) reconstruction is still the most desirable in clinical applications. As the potential candidates with analytic form for the task, the back projection-filtration (BPF) and the derivative backprojection filtered (DBPF) algorithms, in which Hilbert filtering is the common algorithmic feature, are originally derived for exact helical and axial reconstruction from CB and fan beam projection data, respectively. These two algorithms have been heuristically extended for axial CB reconstruction via adoption of virtual PI-line segments. Unfortunately, however, streak artifacts are induced along the Hilbert filtering direction, since these algorithms are no longer accurate on the virtual PI-line segments. We have proposed to cascade the extended BPF/DBPF algorithm with orthogonal butterfly filtering for image reconstruction (namely axial CB-BPP/DBPF cascaded with orthogonal butterfly filtering), in which the orientation-specific artifacts caused by post-BP Hilbert transform can be eliminated, at a possible expense of losing the BPF/DBPF's capability of dealing with projection data truncation. Our preliminary results have shown that this is not the case in practice. Hence, in this work, we carry out an algorithmic analysis and experimental study to investigate the performance of the axial CB-BPP/DBPF cascaded with adequately oriented orthogonal butterfly filtering for three-dimensional (3D) reconstruction in region of interest (ROI).

  18. Axial Vibration Confinement in Nonhomogenous Rods

    Directory of Open Access Journals (Sweden)

    S. Choura

    2005-01-01

    Full Text Available A design methodology for the vibration confinement of axial vibrations in nonhomogenous rods is proposed. This is achieved by a proper selection of a set of spatially dependent functions characterizing the rod material and geometric properties. Conditions for selecting such properties are established by constructing positive Lyapunov functions whose derivative with respect to the space variable is negative. It is shown that varying the shape of the rod alone is sufficient to confine the vibratory motion. In such a case, the vibration confinement requires that the eigenfunctions be exponentially decaying functions of space, where the notion of spatial domain stability is introduced as a concept dual to that of the time domain stability. It is also shown that vibration confinement can be produced if the rod density and/or stiffness are varied with respect to the space variable while the cross-section area is kept constant. Several case studies, supporting the developed conditions imposed on the spatially dependent functions for vibration confinement in vibrating rods, are discussed. Because variation in the geometric and material properties might decrease the critical buckling loads, we also discuss the buckling problem.

  19. Nitinol stent design - understanding axial buckling.

    Science.gov (United States)

    McGrath, D J; O'Brien, B; Bruzzi, M; McHugh, P E

    2014-12-01

    Nitinol׳s superelastic properties permit self-expanding stents to be crimped without plastic deformation, but its nonlinear properties can contribute towards stent buckling. This study investigates the axial buckling of a prototype tracheobronchial nitinol stent design during crimping, with the objective of eliminating buckling from the design. To capture the stent buckling mechanism a computational model of a radial force test is simulated, where small geometric defects are introduced to remove symmetry and allow buckling to occur. With the buckling mechanism ascertained, a sensitivity study is carried out to examine the effect that the transitional plateau region of the nitinol loading curve has on stent stability. Results of this analysis are then used to redesign the stent and remove buckling. It is found that the transitional plateau region can have a significant effect on the stability of a stent during crimping, and by reducing the amount of transitional material within the stent hinges during loading the stability of a nitinol stent can be increased.

  20. Axially Symmetric Post-Newtonian Stellar Systems

    Directory of Open Access Journals (Sweden)

    Camilo Akímushkin

    2010-06-01

    Full Text Available We introduce a method to obtain self-consistent, axially symmetric disklike stellar models in the first post-Newtonian (1PN approximation. By using in the field equations of the 1PN approximation a distribution function (DF corresponding to a Newtonian model, two fundamental equations determining the 1PN corrections are obtained. The rotation curves of the corrected models differs from the classical ones and the corrections are clearly appreciable with values of the mass and radius of a typical galaxy. On the other hand, the relativistic mass correction can be ignored for all models. Resumen. Presentamos un método para obtener modelos estelares discoidales, axialmente simétricos, auto-consistentes en la primera aproximación post-Newtoniana (1PN. Usando en las ecuaciones de campo de la aproximación 1PN una función de distribución conocida (DF que corresponde a un modelo Newtoniano, se obtienen dos ecuaciones fundamentales para determinar las correcciones 1PN. Las curvas de rotación de los modelos corregidos difieren de las clásicas y las correcciones son claramente apreciables con los valores de la masa y el radio de una galaxia típica. Por otro lado, la corrección relativista de la masa se puede ignorar para todos los modelos.

  1. Multimode interaction in axially excited cylindrical shells

    Directory of Open Access Journals (Sweden)

    Silva F. M. A.

    2014-01-01

    Full Text Available Cylindrical shells exhibit a dense frequency spectrum, especially near the lowest frequency range. In addition, due to the circumferential symmetry, frequencies occur in pairs. So, in the vicinity of the lowest natural frequencies, several equal or nearly equal frequencies may occur, leading to a complex dynamic behavior. So, the aim of the present work is to investigate the dynamic behavior and stability of cylindrical shells under axial forcing with multiple equal or nearly equal natural frequencies. The shell is modelled using the Donnell nonlinear shallow shell theory and the discretized equations of motion are obtained by applying the Galerkin method. For this, a modal solution that takes into account the modal interaction among the relevant modes and the influence of their companion modes (modes with rotational symmetry, which satisfies the boundary and continuity conditions of the shell, is derived. Special attention is given to the 1:1:1:1 internal resonance (four interacting modes. Solving numerically the governing equations of motion and using several tools of nonlinear dynamics, a detailed parametric analysis is conducted to clarify the influence of the internal resonances on the bifurcations, stability boundaries, nonlinear vibration modes and basins of attraction of the structure.

  2. New treatment targets for axial spondyloarthritis.

    Science.gov (United States)

    Sieper, Joachim

    2016-12-01

    Axial spondyloarthritis (axSpA) patients can be divided into those with structural damage in the SI joint visible on X-rays, termed radiographic axSpA or AS, and those in an earlier phase of the disease, without structural damage in the SI joint, termed non-radiographic axSpA. TNF-blockers have been shown to be highly effective in the treatment of active axSpA. Interestingly, conventional DMARDs and also non-TNF-blocker biologics targeting IL-1, IL-6 and T cells (abatacept) are not effective. Recent interest has focused on the cytokines IL-23 and IL-17 as potential treatment targets in axSpA. An open-label trial with ustekinumab showed a good efficacy in AS patients. Two placebo-controlled phase 3 trials with a mAb blocking IL-17, secukinumab, showed a good reduction in disease activity, similar to that shown for TNF blockers. Probably triggered by inflammation, new bone formation is another hallmark in AS and a potentially important treatment target. However, a previously reported inhibitory effect of NSAID treatment could not be confirmed in a recent NSAID trial.

  3. The impact of degenerative spinal changes on the correlation of peripheral and axial bone density

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, P. (Klinik und Poliklinik fuer Nuklearmedizin, Wuerzburg Univ. (Germany)); Boerner, W. (Klinik und Poliklinik fuer Nuklearmedizin, Wuerzburg Univ. (Germany))

    1994-08-01

    Results of bone density measurements by quantitative computed tomography of the peripheral skeleton (pQCT) were compared with those of measurements at the axial skeleton with a view to study the effects of degenerative spinal changes on the validity of bone densitometry of the lumbar spine. 556 consecutive patients were examined by dual-energy X-ray absorptiometry (DXA) of the spine and by peripheral quantitative computed tomography (pQCT) of the distal radius. There were significant differences between the bone mineral values at the distal radius and those at the spine, depending on the degree of spinal degeneration. As expected, spinal degenerations showed a highly significant age dependence. With increasing degeneration the correlations between the radius total bone mineral concentration and the bone density of the lumbar spine decreased from r=0.45 to 0.23 in women and from r=0.64 to 0.28 in men. We conclude that the value of spinal DXA is reduced in patients with degenerative spinal disease, compared to the pQCT at the peripheral skeleton. (orig.)

  4. Angular and axial deformities of the legs of children.

    Science.gov (United States)

    McDonough, M W

    1984-12-01

    Age is often a determining factor in establishing a treatment program for these axial and angular problems. As can be seen, the deformities of torsion are noticeable from early life. Any tibial torsion should be treated early, but an excessive medial range of motion in the infant leg with a corresponding adequate lateral range of motion of the limb may be cautiously observed. Medial femoral torsion is a normal early finding in the infant thigh. The problem becomes evident as the child matures without the corresponding reduction in femoral torsion, leading to a persistence of fetal or infantile alignment. The gait consequences are usually noticed at 4 to 8 years of age. The angular changes generally are a delayed finding noticed in stance. The bowleg may be associated with marked tibial torsion and picked up early but the Blount's patient has been traditionally definable at 2 years of age. Levin and Drennan may hasten the time of diagnosis with their radiographic criteria. Knock-knee is an alignment disturbance noticed during the early to mid-childhood years, age 4 to 8 years. The diagnosis is important, differentiating physiologic from torsion-related deformities, and treatment, if warranted, should not be delayed. Generally the earlier these problems are discovered, the more optimistic the prognosis. Since the pediatric limb is in a constant state of transition, there will be a perpetual argument as to the need or efficacy of various approaches to the problems of knock-knee and bowleg. If observation is the treatment of choice, the percentage of cases which go on to osteotomies and epiphyseal stapling will continue. For those with axial or angular deformities, degenerative arthritis of the knee may be forthcoming. Swanson, Greene, and Allis warned of problems becoming "unphysiologic." If we consider the epiphyseal malleability, not only to deformity but to correction, we can appreciate Lenoir's comment of "every day the problem goes untreated is a golden

  5. Análisis de la fuerza axial en un transportador de sinfín // Analysis of axial force in a screw conveyor.

    Directory of Open Access Journals (Sweden)

    F. Aguilar Parés

    1999-01-01

    Full Text Available Durante el movimiento de un material en un transportador de sinfín surge una fuerza en dirección axial que influye en laselección de uno de los cojinetes de apoyo del equipo. En el artículo aparecen algunas soluciones constructivas que tienen encuentan la fuerza axial. Por otro lado se establece la relación entre la fuerza axial y el empuje axial y se precisa de quiendepende el sentido del empuje axial. Por último se propone un modelo matemático que relaciona la fuerza axial con la potenciarequerida por el equipo.Palabras claves: Transportador de sinf in, fuerza axial , empuje axial ._________________________________________________________________________AbstractDuring the movement of material in a screw conveyor surge a force in axial direction that influence in the selection of one ofthe equipment support bearings. Some constructive solutions appear in the article for considering the axial force. In the otherhand it is established the relation between axial force and axial thurst and it is precised whose direction thurst axial depend of.Finally it is proposed a mathematic model that relates the axial force with the power required by the equipment.Key words: Screw conveyor, axial force, axial thurst .

  6. Is there a role for the use of volumetric cone beam computed tomography in periodontics?

    Science.gov (United States)

    du Bois, A H; Kardachi, B; Bartold, P M

    2012-03-01

    Volumetric computed cone beam tomography offers a number of significant advantages over conventional intraoral and extraoral panoramic radiography, as well as computed tomography. To date, periodontal diagnosis has relied heavily on the assessment of both intraoral radiographs and extraoral panoramic radiographs. With emerging technology in radiology there has been considerable interest in the role that volumetric cone beam computed tomography might play in periodontal diagnostics. This narrative reviews the current evidence and considers whether there is a role for volumetric cone beam computed tomography in periodontics.

  7. Active axial spondyloarthritis: potential role of certolizumab pegol

    Directory of Open Access Journals (Sweden)

    Ranatunga S

    2014-02-01

    Full Text Available Sriya Ranatunga, Anne V Miller Department of Internal Medicine, Southern Illinois University School of Medicine, Springfield, IL, USA Abstract: The axial spondyloarthropathies are a group of chronic inflammatory diseases that predominantly affect the axial joints. This group includes ankylosing spondylitis and nonradiographic axial spondyloarthropathy. While the pathogenesis of axial spondyloarthropathies is not clear, immunologically active tissues primarily include the entheses, ie, the areas where ligaments, tendons, and joint capsules attach to bone and to the annulus fibrosis at the vertebrae. One of the major mediators of the immune response in this group of diseases is tumor necrosis factor-alpha (TNFα. Blockade of TNFα results in reduced vascularity and inflammatory cell infiltration in the synovial tissues of affected joints. Certolizumab pegol (CZP is an Fc-free, PEGylated anti-TNFα monoclonal antibody. CZP has unique properties that differ from other available TNFα inhibitors by virtue of its lack of an Fc region, which minimizes potential Fc-mediated effects, and its PEGylation, which improves drug pharmacokinetics and bioavailability. It has been shown in clinical trials that CZP improves patient outcomes and reduces inflammation in the sacroiliac joints and spine in both ankylosing spondylitis and nonradiographic axial spondyloarthropathies. These data support CZP as a treatment option for axial spondyloarthropathies. Keywords: axial spondyloarthropathy, certolizumab pegol, anti-tumor necrosis factor-alpha, therapy

  8. Radial Reflection Diffraction Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lehman, S K; Norton, S J

    2003-10-10

    We develop a wave-based tomographic imaging algorithm based upon a single rotating radially outward oriented transducer. At successive angular locations at a fixed radius, the transducer launches a primary field and collects the backscattered field in a ''pitch/catch'' operation. The hardware configuration, operating mode, and data collection method is identical to that of most medical intravascular ultrasound (IVUS) systems. IVUS systems form images of the medium surrounding the probe based upon ultrasonic B-scans, using a straight-ray model of sound propagation. Our goal is to develop a wave-based imaging algorithm using diffraction tomography techniques. Given the hardware configuration and the imaging method, we refer to this system as ''radial reflection diffraction tomography.'' We consider two hardware configurations: a multimonostatic mode using a single transducer as described above, and a multistatic mode consisting of a single transmitter and an aperture formed by multiple receivers. In this latter case, the entire source/receiver aperture rotates about the fixed radius. Practically, such a probe is mounted at the end of a catheter or snaking tube that can be inserted into a part or medium with the goal of forming images of the plane perpendicular to the axis of rotation. We derive an analytic expression for the multimonostatic inverse but ultimately use the new Hilbert space inverse wave (HSIW) algorithm to construct images using both operating modes. Applications include improved IVUS imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts with existing access holes.

  9. Evaluation of reformatted sagittal CT images for measurement of condylar position. Comparison between original axial and coronal images

    Energy Technology Data Exchange (ETDEWEB)

    Hiruma, Takayoshi; Funato, Masahiko; Suganuma, Takeshi; Shinya, Akiyuki; Furuya, Ryoichi; Kawawa, Tadaharu; Seki, Kenji; Okano, Tomohiro [Showa Univ., Tokyo (Japan). School of Dentistry

    1995-09-01

    Accurate measurement of the condylar position is important for diagnosis and treatment of temporomandibular joint dysfunction. Conventional radiographic techniques have been used for this purpose and the recent advance of computed tomography (CT) is applicable to temporomandibular joints. The accuracy of CT in the measurement of the condylar position is still unclear. The purpose of this study was to evaluate the measurement accuracy of the condylar position on reformatted sagittal CT images. Six TMJs obtained from dried skulls were used. The TMJs were examined using a CT scanner with 1 mm thickness/interval in the axial and coronal directions. The visibility of the condyle and fossa on the reformatted sagittal images created were evaluated by measuring the joint space defined in our study. The results were as follows: (1) The superior surface of the condyle and the deepest part of the fossa were obscured in the reformatted images created from the axial scan and coronal scan projected at 60deg to the F-H plane. (2) The reformatted images from the coronal scan projected at 90deg, 80deg or 70deg to the F-H plane clearly depicted the condyle and fossa, the reproducibility of the measurement on these images mentioned above was less than 0.1 mm. The results indicated that the coronal scan from 90deg to 70deg to the F-H plane is more accurate than the axial scan for determining the condylar position on the reformatted sagittal images. (author).

  10. Computed tomography of the brain in kwashiorkor: a follow up study.

    OpenAIRE

    Househam, K C

    1991-01-01

    Computed tomography of the brain was performed initially and after nutritional rehabilitation on 12 children with kwashiorkor. The severe cerebral shrinkage evident initially resolved after nutritional rehabilitation. The mechanism and significance of this reversible abnormality remains to be determined.

  11. Dynamic Analysis of Axial Magnetic Forces for DVD Spindle Motors

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The axial magnetic force, induced by the complicated flux linkage distribution from rotor magnet and stator slotted, is constructed by different relative heights and calculated by 3D finite element method (FEM) to analyze the dynamic characteristics for a DVD spindle motor. The axial magnetic force is designed to provide an axial stiffness and govern the natural frequency of the dynamic performance. According to the simulation results and experimental measurements, the dynamic behaviors are significantly improved with a variation of relative height of rotor magnet and stator slotted on a DVD spindle motor.

  12. The axial charges of the hidden-charm pentaquark states

    CERN Document Server

    Wang, Guang-Juan; Zhu, Shi-Lin

    2016-01-01

    With the chiral quark model, we have calculated the axial charges of the pentaquark states with $(I,I_3)=(\\frac{1}{2},\\frac{1}{2})$ and $J^{P}=\\frac{1}{2}^{\\pm},\\frac{3}{2}^{\\pm},\\frac{5}{2}^{\\pm}$. The $P_c$ states with the same $J^P$ quantum numbers but different color-spin-flavor configurations have very different axial charges, which encode important information on their underlying structures. For some of the $J^{P}=\\frac{3}{2}^{\\pm}$ or $\\frac{5}{2}^{\\pm}$ pentaquark states, their axial charges are much smaller than that of the proton.

  13. Tensile Property of Bi-axial Warp Knitted Structure

    Institute of Scientific and Technical Information of China (English)

    沈为

    2003-01-01

    The tensile property of bi-axial warp knitted fabrics is tested and compared with that of the plain weave fabric. The results show that there are obvious differences between the tensile property of a bi-axial warp knitted fabric and that of a plain weave fabric.The former can give fuller play to the property of a high modulus yarn than the latter. The tensile strength of a bi-axial warp knitted fabric is linear with the number of yarns in the direction of force.

  14. Gravitational waves from the axial perturbations of hyperon stars

    Institute of Scientific and Technical Information of China (English)

    Wen De-Hua; Yan Jing; Liu Xue-Mei

    2012-01-01

    The eigen-frequencies of the axial w-mode oscillations of hyperon stars are examined.It is shown that as the appearance of hyperons softens the equation of state of the super-density matter,the frequency of gravitational waves from the axial w-mode of hyperon star becomes smaller than that of a traditional neutron star at the same stellar mass.Moreover,the eigenfrequencies of hyperon stars also have scaling universality.It is shown that the EURO thirdgeneration gravitational-wave detector has the potential to detect the gravitational-wave signal emitted from the axial w-mode oscillations of a hyperon star.

  15. Evolution prediction from tomography

    Science.gov (United States)

    Dominy, Jason M.; Venuti, Lorenzo Campos; Shabani, Alireza; Lidar, Daniel A.

    2017-03-01

    Quantum process tomography provides a means of measuring the evolution operator for a system at a fixed measurement time t. The problem of using that tomographic snapshot to predict the evolution operator at other times is generally ill-posed since there are, in general, infinitely many distinct and compatible solutions. We describe the prediction, in some "maximal ignorance" sense, of the evolution of a quantum system based on knowledge only of the evolution operator for finitely many times 0evolution at times away from the measurement times. Even if the original evolution is unitary, the predicted evolution is described by a non-unitary, completely positive map.

  16. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  17. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  18. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  19. Compressive Phase Contrast Tomography

    CERN Document Server

    Maia, F R N C; Marchesini, S; Padmore, H A; Parkinson, D Y; Pien, J; Schirotzek, A; Yang, C; 10.1117/12.861946

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. In- terference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher con- trast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  20. Hyperspectral optical diffraction tomography

    CERN Document Server

    Jung, JaeHwang; Yoon, Jonghee; Park, YongKeun

    2015-01-01

    Here, we present a novel microscopic technique for measuring wavelength-dependent three-dimensional (3-D) distributions of the refractive indices (RIs) of microscopic samples in the visible wavelengths. Employing 3-D quantitative phase microscopy techniques with a wavelength-swept source, 3-D RI tomograms were obtained in the range of 450 - 700 nm with a spectral resolution of a few nanometers. The capability of the technique was demonstrated by measuring the hyperspectral 3-D RI tomograms of polystyrene beads, human red blood cells, and hepatocytes. The results demonstrate the potential for label-free molecular specific 3-D tomography of biological samples.

  1. Atom probe tomography today

    Directory of Open Access Journals (Sweden)

    Alfred Cerezo

    2007-12-01

    Full Text Available This review aims to describe and illustrate the advances in the application of atom probe tomography that have been made possible by recent developments, particularly in specimen preparation techniques (using dual-beam focused-ion beam instruments but also of the more routine use of laser pulsing. The combination of these two developments now permits atomic-scale investigation of site-specific regions within engineering alloys (e.g. at grain boundaries and in the vicinity of cracks and also the atomic-level characterization of interfaces in multilayers, oxide films, and semiconductor materials and devices.

  2. Abdominal perfusion computed tomography.

    Science.gov (United States)

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-02-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

  3. Tomography finds waste sites

    Science.gov (United States)

    Bush, Susan M.

    Geophysical diffraction tomography (GDT), a remote sensing method, is being developed for hazardous waste site characterization by researchers at Oak Ridge National Laboratory, Tenn., with the support of the U.S. Army Toxic and Hazardous Materials Agency, Aberdeen Proving Ground, Md.More accurate assessment of hazardous sites translates into more efficient and less costly cleanup efforts by defining parameters such as waste site boundaries, geophysical site characteristics, buried container leakage, and hazardous material migration. Remote sensing devices eliminate the potential for environmental damage, safety hazards, or high costs associated with intrusive site characterization techniques.

  4. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  5. Radial reflection diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lehman, Sean K.

    2012-12-18

    A wave-based tomographic imaging method and apparatus based upon one or more rotating radially outward oriented transmitting and receiving elements have been developed for non-destructive evaluation. At successive angular locations at a fixed radius, a predetermined transmitting element can launch a primary field and one or more predetermined receiving elements can collect the backscattered field in a "pitch/catch" operation. A Hilbert space inverse wave (HSIW) algorithm can construct images of the received scattered energy waves using operating modes chosen for a particular application. Applications include, improved intravascular imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts having existing access holes.

  6. Revealing atropisomer axial chirality in drug discovery.

    Science.gov (United States)

    LaPlante, Steven R; Edwards, Paul J; Fader, Lee D; Jakalian, Araz; Hucke, Oliver

    2011-03-07

    An often overlooked source of chirality is atropisomerism, which results from slow rotation along a bond axis due to steric hindrance and/or electronic factors. If undetected or not managed properly, this time-dependent chirality has the potential to lead to serious consequences, because atropisomers can be present as distinct enantiomers or diastereoisomers with their attendant different properties. Herein we introduce a strategy to reveal and classify compounds that have atropisomeric chirality. Energy barriers to axial rotation were calculated using quantum mechanics, from which predicted high barriers could be experimentally validated. A calculated rotational energy barrier of 20 kcal mol(-1) was established as a suitable threshold to distinguish between atropisomers and non-atropisomers with a prediction accuracy of 86%. This methodology was applied to subsets of drug databases in the course of which atropisomeric drugs were identified. In addition, some drugs were exposed that were not yet known to have this chiral attribute. The most valuable utility of this tool will be to predict atropisomerism along the drug discovery pathway. When used in concert with our compound classification scheme, decisions can be made during early discovery stages such as "hit-to-lead" and "lead optimization," to foresee and validate the presence of atropisomers and to exercise options of removing, further stabilizing, or rendering the chiral axis of interest more freely rotatable via SAR design, thereby decreasing this potential liability within a compound series. The strategy can also improve drug development plans, such as determining whether a drug or series should be developed as a racemic mixture or as an isolated single compound. Moreover, the work described herein can be extended to other chemical fields that require the assessment of potential chiral axes.

  7. Computed tomography in neuronal ceroid lipofuscinosis

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neuronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter.

  8. Cork quality estimation by using Compton tomography

    CERN Document Server

    Brunetti, A; Golosio, B; Luciano, P; Ruggero, A

    2002-01-01

    The quality control of cork stoppers is mandatory in order to guarantee the perfect conservation of the wine. Several techniques have been developed but until now the quality control was essentially related to the status of the external surface. Thus possible cracks or holes inside the stopper will be hidden. In this paper a new technique based on X-ray Compton tomography is described. It is a non-destructive technique that allows one to reconstruct and visualize the cross-section of the cork stopper analyzed, and so to put in evidence the presence of internal imperfections. Some results are reported and compared with visual classification.

  9. Imaging actinic keratosis by high-definition optical coherence tomography. Histomorphologic correlation

    DEFF Research Database (Denmark)

    Boone, Marc A L M; Norrenberg, Sarah; Jemec, Gregor B E;

    2013-01-01

    transversal and axial directions, enable to visualize individual cells up to a depth of around 570 μm filling the imaging gap between conventional optical coherence tomography and reflectance confocal microscopy. We sought to determine the feasibility of detecting and grading of actinic keratosis...... by this technique using criteria defined for reflectance confocal microscopy compared to histology. In this pilot study, skin lesions of 17 patients with a histologically proven actinic keratosis were imaged by high-definition optical coherence tomography just before excision and images analysed qualitatively...... of photodamage. Using features already suggested by reflectance confocal microscopy, the study implies that high-definition optical coherence tomography facilitates in vivo diagnosis of actinic keratosis and allows the grading of different actinic keratosis lesions for increased clinical utility....

  10. The Design Method of Axial Flow Runners Focusing on Axial Flow Velocity Uniformization and Its Application to an Ultra-Small Axial Flow Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2016-01-01

    Full Text Available We proposed a portable and ultra-small axial flow hydraulic turbine that can generate electric power comparatively easily using the low head of open channels such as existing pipe conduits or small rivers. In addition, we proposed a simple design method for axial flow runners in combination with the conventional one-dimensional design method and the design method of axial flow velocity uniformization, with the support of three-dimensional flow analysis. Applying our design method to the runner of an ultra-small axial flow hydraulic turbine, the performance and internal flow of the designed runner were investigated using CFD analysis and experiment (performance test and PIV measurement. As a result, the runners designed with our design method were significantly improved in turbine efficiency compared to the original runner. Specifically, in the experiment, a new design of the runner achieved a turbine efficiency of 0.768. This reason was that the axial component of absolute velocity of the new design of the runner was relatively uniform at the runner outlet in comparison with that of the original runner, and as a result, the negative rotational flow was improved. Thus, the validity of our design method has been verified.

  11. Value of computed tomography for evaluating the sub glottis in laryngeal and hypopharyngeal squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Ricardo Pires de; Barros, Nestor de; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza; Rapoport, Abrao; Cerri, Giovanni Guido [Hospital Heliopolis, Sao Paulo, SP (Brazil). Dept. de Cirurgia de Cabeca e Pescoco, Otorrinolaringologia e Imagem]. E-mail: ricapires@ig.com.br; olger1@uol.com.br

    2007-03-15

    Context And Objective: Sub glottic involvement in squamous cell carcinoma is a determining factor for contraindicating conservative partial surgery. The subglottis is easily identified by axial computed tomography sections. The present study aimed to evaluate the occurrence of false-negative and false-positive results, and the overall accuracy of staging by computed tomography, in order to detect the involvement of the subglottic laryngeal compartment, in cases of laryngeal and hypopharyngeal squamous cell carcinoma. Design And Setting: Retrospective, non-randomized study of patients treated at Hospital Heliopolis, Sao Paulo, Brazil. Methods: Computed tomography scans were performed on third-generation equipment with 5-mm slice thickness. Afterwards, all patients underwent surgical and anatomopathological examinations as the gold standard procedures. Results: Among 60 patients, 14 were diagnosed with subglottic extension by surgical and histopathological examination. There were three false-negative and no false-positive results from computed tomography scans. The sensitivity and negative predictive value were 100.0%. Accuracy was 95.0%, specificity was 93.5% and positive predictive value was 82.4%. Conclusions: Computed tomography could serve as a powerful auxiliary method for staging laryngeal and hypopharyngeal cancer. However, precautions should be taken in analyzing computed tomography scan data, because vegetating lesions may also be projected into the subglottic compartment, without real involvement of the subglottis, which may cause a false-positive result. (author)

  12. Application of computed tomography to spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Sha, N.; Kurihara, A.; Kataoka, O. (Kobe Univ. (Japan). School of Medicine)

    1980-08-01

    The axial tomographic examination of the spine and its soft tissues is now readily available for orthopaedic surgery. If the appropriate conditions are maintained, computed tomography (CT) can provide useful information concerning the diagnosis and the treatment of spinal diseases. There are, however, some pitfalls in interpreting CT scans: 1) the existence of the lesion may be masked, and 2) its extent and configuration may be over- or under-evaluated depending on such technical factors as the slicing level, the slicing angle, the window width, and the window level. Experimental studies were carried out on a plaster of Paris model of the spine and a cadaver spine to determine the appropriate technical factors by which the CT (EMI whole body CT scanner 5005) can be applied accurately to a diseased spine. The factors obtained were then applied in examining ninety-nine patients with various spinal disorders. Window levels ranging between 100 and 150 were found to be most appropriate. The slicing angle should be 90/sup 0/, or perpendicular to the long axis of the object under study. However, deviations of +10 or -10 degrees are acceptable. The CT view of the spine may be divided into two patterns at the cervical and thoracic levels and into three patterns at the lumbar level. In addition, the usefulness and the diagnostic value of CT for various spinal problems are discussed based on our clinical material.

  13. Uniform versus Nonuniform Axial Power Distribution in Rod Bundle CHF Experiments

    Directory of Open Access Journals (Sweden)

    Baowen Yang

    2014-01-01

    Full Text Available Rod bundle experiments with axially uniform and nonuniform heat fluxes are examined to explore the potential limitations of using uniform rod bundle CHF data for CHF correlation development of light water reactors with nonuniform axial power distribution (APD. The case of upstream burnout is presented as an example of unique phenomena associated with nonuniform rod bundle CHF experiments. It is a result from combined effect of axial nonuniform power shape and different interchannel mixing mechanisms. In addition, several key parameters are investigated with respect to their potential impacts on the thermal-hydraulic behaviors between rod bundles with uniform and nonuniform APDs. This type of misrepresentation cannot be amended or compensated through the use of correction factors due to the lack of critical information in the uniform rod bundle CHF testing as well as the fundamental difference in the underlining driving mechanisms. Other potential issues involved with the use of uniform rod bundle CHF data for nonuniform APD system applications also present strong evidence concerning the limitations and inadequacy of using uniform rod bundle CHF data for the correlation, prediction, and design limit calculation for safety analysis.

  14. Advances in classification, basic mechanisms and clinical science in ankylosing spondylitis and axial spondyloarthritis.

    Science.gov (United States)

    Robinson, P C; Benham, H

    2015-02-01

    The field of spondyloarthritis (SpA) has seen huge advances over the past 5 years. The classification of axial disease has been redefined by the axial SpA criteria that incorporate disease captured before radiographic damage is evident as well as established erosive sacroiliac joint disease. Our knowledge of genetics and basic immunological pathways has progressed significantly. In addition, revolutionary progress has been achieved with the availability of tumour necrosis factor inhibitors for treating patients with moderate to severe disease. In parallel, several of novel biomarkers have been identified that show significant promise for the future. Advances in magnetic resonance imaging have helped define positive disease. We have identified that T1 and short tau inversion recovery sequences are best for the diagnosis of axial SpA, and gadolinium contrast is not additive for diagnosis. Progress has been made in identifying potential agents and strategies that reduce radiographic progression. Several referral strategies aimed at appropriate identification of patients have been trialled and found to be effective. There is still substantial work ahead, but the advances of the last 5 years have made a huge and tangible difference at the clinical coalface, and we suggest that this trend will continue.

  15. Compressed sensing electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Leary, Rowan, E-mail: rkl26@cam.ac.uk [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Saghi, Zineb; Midgley, Paul A. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Holland, Daniel J. [Department of Chemical Engineering and Biotechnology, University of Cambridge, New Museums Site, Pembroke Street, Cambridge CB2 3RA (United Kingdom)

    2013-08-15

    The recent mathematical concept of compressed sensing (CS) asserts that a small number of well-chosen measurements can suffice to reconstruct signals that are amenable to sparse or compressible representation. In addition to powerful theoretical results, the principles of CS are being exploited increasingly across a range of experiments to yield substantial performance gains relative to conventional approaches. In this work we describe the application of CS to electron tomography (ET) reconstruction and demonstrate the efficacy of CS–ET with several example studies. Artefacts present in conventional ET reconstructions such as streaking, blurring of object boundaries and elongation are markedly reduced, and robust reconstruction is shown to be possible from far fewer projections than are normally used. The CS–ET approach enables more reliable quantitative analysis of the reconstructions as well as novel 3D studies from extremely limited data. - Highlights: • Compressed sensing (CS) theory and its application to electron tomography (ET) is described. • The practical implementation of CS–ET is outlined and its efficacy demonstrated with examples. • High fidelity tomographic reconstruction is possible from a small number of images. • The CS–ET reconstructions can be more reliably segmented and analysed quantitatively. • CS–ET is applicable to different image content by choice of an appropriate sparsifying transform.

  16. Internal tide oceanic tomography

    Science.gov (United States)

    Zhao, Zhongxiang

    2016-09-01

    A concept of internal tide oceanic tomography (ITOT) is proposed to monitor ocean warming on a global scale. ITOT is similar to acoustic tomography, but that work waves are internal tides. ITOT detects ocean temperature changes by precisely measuring travel time changes of long-range propagating internal tides. The underlying principle is that upper ocean warming strengthens ocean stratification and thus increases the propagation speed of internal tides. This concept is inspired by recent advances in observing internal tides by satellite altimetry. In particular, a plane wave fit method can separately resolve multiple internal tidal waves and thus accurately determines the phase of each wave. Two examples are presented to demonstrate the feasibility and usefulness of ITOT. In the eastern tropical Pacific, the yearly time series of travel time changes of the M2 internal tide is closely correlated with the El Niño-Southern Oscillation index. In the North Atlantic, significant interannual variations and bidecadal trends are observed and consistent with the changes in ocean heat content measured by Argo floats. ITOT offers a long-term, cost-effective, environmentally friendly technique for monitoring global ocean warming. Future work is needed to quantify the accuracy of this technique.

  17. Advances in neutron tomography

    Indian Academy of Sciences (India)

    W Treimer

    2008-11-01

    In the last decade neutron radiography (NR) and tomography (NCT) have experienced a number of improvements, due to the well-known properties of neutrons interacting with matter, i.e. the low attenuation by many materials, the strong attenuation by hydrogenous constituent in samples, the wavelength-dependent attenuation in the neighbourhood of Bragg edges and due to better 2D neutron detectors. So NR and NCT were improved by sophisticated techniques that are based on the attenuation of neutrons or on phase changes of the associated neutron waves if they pass through structured materials. Up to now the interaction of the neutron spin with magnetic fields in samples has not been applied to imaging techniques despite the fact that it was proposed many years ago. About ten years ago neutron depolarization as imaging signal for neutron radiography or tomography was demonstrated and in principle it works. Now one can present much improved test experiments using polarized neutrons for radiographic imaging. For this purpose the CONRAD instrument of the HMI was equipped with polarizing and analysing benders very similar to conventional scattering experiments using polarized neutrons. Magnetic fields in different coils and in samples (superconductors) at low temperatures could be visualized. In this lecture a summary about standard signals (attenuation) and the more `sophisticated' imaging signals as refraction, small angle scattering and polarized neutrons will be given.

  18. Waste inspection tomography (WIT)

    Energy Technology Data Exchange (ETDEWEB)

    Bernardi, R.T. [Bio-Imaging Research, Inc., Lincolnshire, IL (United States)

    1995-10-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU.

  19. Radial breathing mode of carbon nanotubes subjected to axial pressure.

    Science.gov (United States)

    Lei, Xiao-Wen; Ni, Qing-Qing; Shi, Jin-Xing; Natsuki, Toshiaki

    2011-08-11

    In this paper, a theoretical analysis of the radial breathing mode (RBM) of carbon nanotubes (CNTs) subjected to axial pressure is presented based on an elastic continuum model. Single-walled carbon nanotubes (SWCNTs) are described as an individual elastic shell and double-walled carbon nanotubes (DWCNTs) are considered to be two shells coupled through the van der Waals force. The effects of axial pressure, wave numbers and nanotube diameter on the RBM frequency are investigated in detail. The validity of these theoretical results is confirmed through the comparison of the experiment, calculation and simulation. Our results show that the RBM frequency is linearly dependent on the axial pressure and is affected by the wave numbers. We concluded that RBM frequency can be used to characterize the axial pressure acting on both ends of a CNT.

  20. ANALYSIS OF PULSATILE BLOOD FLOW IN AXIALLY MOVING ARTERIES

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In order to study motional properties of pulsatile blood flow in axially moving arteries, the authors derived some expressions of the pulsatile blood flow from the basic equations of motion for blood and vascular walls, including an axial blood velocity equation, a flow rate equation and a wall shear stress equation, which described not only the overall axial movement of the arteries but also the elastic properties of the vascular walls, discussed the effects of the arterial wall elasticity on the wall shear stress in coronary arteries in terms of these expressions, and analyzed changes of motional properties of pulsatile blood flow between an elastic arterial tube model and a rigid tube model. The results proved the inference by J.E. Moore Jr. et al. (1994) that the axial movement of arteries be as important in determining coronary artery hemodynamics as the elastic property of the vascular wall.

  1. The geometrical theory of diffraction for axially symmetric reflectors

    DEFF Research Database (Denmark)

    Rusch, W.; Sørensen, O.

    1975-01-01

    The geometrical theory of diffraction (GTD) (cf. [1], for example) may be applied advantageously to many axially symmetric reflector antenna geometries. The material in this communication presents analytical, computational, and experimental results for commonly encountered reflector geometries...

  2. Axial Stringy System of the Kerr Spinning Particle

    CERN Document Server

    Burinskii, A

    2004-01-01

    The structure of classical spinning particle based on the Kerr-Newman black hole (BH) solution is investigated. For large angular momentum, $|a|>>m$, the BH horizons disappear exposing a naked ringlike source which is a circular relativistic string. It was shown recently that electromagnetic excitations of this string lead to the appearance of an extra axial stringy system which consists of two half-infinite strings of opposite chirality. In this paper we consider the relation of this stringy system to the Dirac equation. We also show that the axial strings are the Witten superconducting strings and describe their structure by the Higgs field model where the Higgs condensate is used to regularize axial singularity. We argue that this axial stringy system may play the role of a classical carrier of the wave function.

  3. Open-Axial-Field Magnet at ISR intersection I8

    CERN Multimedia

    1979-01-01

    This axial field spectrometer left the central collision region unobstructed in order to ease analysis of secondary particles emitted at large angle. The ISR circulating beams were passing through a hole in the magnet poles.

  4. Axial mesodermal dysplasia complex: a new case with parental consanguinity.

    Science.gov (United States)

    Mota, C R; Azevedo, M; Rocha, G; Manuela, F; Coelho, R; Lima, M R

    2000-01-01

    A female is described with axial mesodermal dysplasia complex (AMDC) born to a consanguineous couple. This is thought to be the first description of a patient with AMDC born to consanguineous parents.

  5. Metrizamide computed tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, T.; Tamakawa, Y.; Arii, H. (Akita Univ. (Japan). Faculty of Medicine); Takahashi, M.; Hirota, K.

    1981-11-01

    Serial computed tomography of the cervical cord was performed following metrizamide myelography in five cases of clinically suspected syringomyelia. The syrinx filled with refluxed metrizamide was demonstrated in all of the cases. The reflux of metrizamide into the syrinx was most marked several hours following intrathecal injection of metrizamide. Computed tomography combined with metrizamide myelography is essential in the diagnosis of communicating syringomyelia.

  6. Osteolytic extra-axial sacral myxopapillary ependymoma

    Energy Technology Data Exchange (ETDEWEB)

    Biagini, R.; Demitri, S.; Orsini, U. [Clinica Ortopedica, Istituto Ortopedico Rizzoli, Bologna (Italy); Bibiloni, J. [Medical Sciences Campus San Juan, University of Puerto Rico (Puerto Rico); Briccoli, A. [Istituto di Patologia Chirurgica, University of Modena (Italy); Bertoni, F. [Servizio di Anatomia Patologica, Istituto Ortopedico Rizzoli Bologna (Italy)

    1999-10-01

    The authors report an unusual case of sacral osteolytic myxopapillary ependymoma treated with curettage and radiotherapy. There is no evidence of recurrence 8 years after treatment. A review of the literature is presented on sacral ependymomas presenting with an osteolytic radiographic appearance (24 cases in 18 reports). The differential diagnosis with other sacral neoplasms is discussed. (orig.)

  7. Axial Anomaly in Lattice Abelian Gauge Theory in Arbitrary Dimensions

    CERN Document Server

    Fujiwara, T; Wu, K; Fujiwara, Takanori; Suzuki, Hiroshi; Wu, Ke

    1999-01-01

    Axial anomaly of lattice abelian gauge theory in hyper-cubic regular lattice in arbitrary even dimensions is investigated by applying the method of exterior differential calculus. The topological invariance, gauge invariance and locality of the axial anomaly determine the explicit form of the topological part. The anomaly is obtained up to a multiplicative constant for finite lattice spacing and can be interpreted as the Chern character of the abelian lattice gauge theory.

  8. Axially astigmatic surfaces: different types and their properties

    Science.gov (United States)

    Malacara-Doblado, Daniel; Malacara-Hernandez, Daniel; Garcia-Marquez, Jorge L.

    1996-12-01

    Axially astigmatic surfaces have different curvatures in orthogonal diameters. Toroidal and spherocylindrical optical surfaces are two mathematically different special cases of axially astigmatic surfaces as noted by Menchaca and Malacara (1986), but they are almost identical in the vicinity of the optical axis. The different between these two surfaces increases when the distance to the optical axis increases. We study the general properties of astigmatic surfaces and some special interesting cases.

  9. Testing of Axially Loaded Bucket Foundation with Applied Overburden Pressure

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    This report analyses laboratory testing data performed with a bucket foundation model subjected to axial loading. The examinations were conducted at the Geotechnical laboratory of Aalborg University. The report aims at showing and discussing the results of the static and cyclic axial loading tests...... on the bucket foundation model. Finally, a cyclic loading interaction diagram is given that can be applied for a full-scale bucket foundation design....

  10. Watson's theorem and the $N\\Delta(1232)$ axial transition

    CERN Document Server

    Alvarez-Ruso, L; Nieves, J; Vacas, M J Vicente

    2016-01-01

    We present a new determination of the $N\\Delta$ axial form factors from neutrino induced pion production data. For this purpose, the model of Hernandez et al., Phys. Rev. D76, 033005 (2007) is improved by partially restoring unitarity. This is accomplished by imposing Watson's theorem on the dominant vector and axial multipoles. As a consequence, a larger $C_5^A(0)$, in good agreement with the prediction from the off-diagonal Goldberger-Treiman relation, is now obtained.

  11. Method to Measure Tone of Axial and Proximal Muscle

    OpenAIRE

    2011-01-01

    The control of tonic muscular activity remains poorly understood. While abnormal tone is commonly assessed clinically by measuring the passive resistance of relaxed limbs1, no systems are available to study tonic muscle control in a natural, active state of antigravity support. We have developed a device (Twister) to study tonic regulation of axial and proximal muscles during active postural maintenance (i.e. postural tone). Twister rotates axial body regions relative to each other about the ...

  12. Axially symmetric volume constrained anisotropic mean curvature flow

    CERN Document Server

    Palmer, Bennett

    2011-01-01

    We study the long time existence theory for a non local flow associated to a free boundary problem for a trapped non liquid drop. The drop has free boundary components on two horizontal plates and its free energy is anisotropic and axially symmetric. For axially symmetric initial surfaces with sufficiently large volume, we show that the flow exists for all time. Numerical simulations of the curvature flow are presented.

  13. Fluoroscopic lumbar interlaminar epidural injections in managing chronic lumbar axial or discogenic pain.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Cash, Kimberly A; McManus, Carla D; Pampati, Vidyasagar; Benyamin, Ramsin

    2012-01-01

    Among the multiple causes of chronic low back pain, axial and discogenic pain are common. Various modalities of treatments are utilized in managing discogenic and axial low back pain including epidural injections. However, there is a paucity of evidence regarding the effectiveness, indications, and medical necessity of any treatment modality utilized for managing axial or discogenic pain, including epidural injections. In an interventional pain management practice in the US, a randomized, double-blind, active control trial was conducted. The objective was to assess the effectiveness of lumbar interlaminar epidural injections of local anesthetic with or without steroids for managing chronic low back pain of discogenic origin. However, disc herniation, radiculitis, facet joint pain, or sacroiliac joint pain were excluded. Two groups of patients were studied, with 60 patients in each group receiving either local anesthetic only or local anesthetic mixed with non-particulate betamethasone. Primary outcome measures included the pain relief-assessed by numeric rating scale of pain and functional status assessed by the, Oswestry Disability Index, Secondary outcome measurements included employment status, and opioid intake. Significant improvement or success was defined as at least a 50% decrease in pain and disability. Significant improvement was seen in 77% of the patients in Group I and 67% of the patients in Group II. In the successful groups (those with at least 3 weeks of relief with the first two procedures), the improvement was 84% in Group I and 71% in Group II. For those with chronic function-limiting low back pain refractory to conservative management, it is concluded that lumbar interlaminar epidural injections of local anesthetic with or without steroids may be an effective modality for managing chronic axial or discogenic pain. This treatment appears to be effective for those who have had facet joints as well as sacroiliac joints eliminated as the pain source.

  14. Aerodynamics and combustion of axial swirlers

    Science.gov (United States)

    Fu, Yongqiang

    A multipoint lean direct injection (LDI) concept was introduced recently in non-premixed combustion to obtain both low NOx emissions and good combustion stability. In this concept, a key feature is the injection of finely atomized fuel into the high-swirling airflow at the combustor dome that provides a homogenous, lean fuel-air mixture. In order to achieve the fine atomization and mixing of the fuel and air quickly and uniformly, a good swirler design should be studied. The focus of this dissertation is to investigate the aerodynamics and combustion of the swirling flow field in a multipoint Lean Direct Injector combustor. A helical axial-vaned swirler with a short internal convergent-divergent venturi was used. Swirlers with various vane angles and fuel nozzle insertion lengths have been designed. Three non-dimensional parameter effects on non-reacting, swirling flow field were studied: swirler number, confinement ratio and Reynolds number. Spray and combustion characteristics on the single swirler were studied to understand the mechanism of fuel-air mixing in this special configuration. Multi-swirler interactions were studied by measuring the confined flow field of a multipoint swirler array with different configurations. Two different swirler arrangements were investigated experimentally, which include a co-swirling array and a counter-swirling array. In order to increase the range of stability of multipoint LDI combustors, an improved design were also conducted. The results show that the degree of swirl and the level of confinement have a clear impact on the mean and turbulent flow fields. The swirling flow fields may also change significantly with the addition of a variety of simulated fuel nozzle insertion lengths. The swirler with short insertion has the stronger swirling flow as compared with the long insertion swirler. Reynolds numbers, with range of current study, will not alter mean and turbulent properties of generated flows. The reaction of the spray

  15. Slow axial drift in three-dimensional granular tumbler flow

    Science.gov (United States)

    Zaman, Zafir; D'Ortona, Umberto; Umbanhowar, Paul B.; Ottino, Julio M.; Lueptow, Richard M.

    2013-07-01

    Models of monodisperse particle flow in partially filled three-dimensional tumblers often assume that flow along the axis of rotation is negligible. We test this assumption, for spherical and double cone tumblers, using experiments and discrete element method simulations. Cross sections through the particle bed of a spherical tumbler show that, after a few rotations, a colored band of particles initially perpendicular to the axis of rotation deforms: particles near the surface drift toward the pole, while particles deeper in the flowing layer drift toward the equator. Tracking of mm-sized surface particles in tumblers with diameters of 8-14 cm shows particle axial displacements of one to two particle diameters, corresponding to axial drift that is 1-3% of the tumbler diameter, per pass through the flowing layer. The surface axial drift in both double cone and spherical tumblers is zero at the equator, increases moving away from the equator, and then decreases near the poles. Comparing results for the two tumbler geometries shows that wall slope causes axial drift, while drift speed increases with equatorial diameter. The dependence of axial drift on axial position for each tumbler geometry is similar when both are normalized by their respective maximum values.

  16. Axial scanning in confocal microscopy employing adaptive lenses (CAL).

    Science.gov (United States)

    Koukourakis, Nektarios; Finkeldey, Markus; Stürmer, Moritz; Leithold, Christoph; Gerhardt, Nils C; Hofmann, Martin R; Wallrabe, Ulrike; Czarske, Jürgen W; Fischer, Andreas

    2014-03-10

    In this paper we analyze the capability of adaptive lenses to replace mechanical axial scanning in confocal microscopy. The adaptive approach promises to achieve high scan rates in a rather simple implementation. This may open up new applications in biomedical imaging or surface analysis in micro- and nanoelectronics, where currently the axial scan rates and the flexibility at the scan process are the limiting factors. The results show that fast and adaptive axial scanning is possible using electrically tunable lenses but the performance degrades during the scan. This is due to defocus and spherical aberrations introduced to the system by tuning of the adaptive lens. These detune the observation plane away from the best focus which strongly deteriorates the axial resolution by a factor of ~2.4. Introducing balancing aberrations allows addressing these influences. The presented approach is based on the employment of a second adaptive lens, located in the detection path. It enables shifting the observation plane back to the best focus position and thus creating axial scans with homogeneous axial resolution. We present simulated and experimental proof-of-principle results.

  17. Reactive control of subsonic axial fan noise in a duct.

    Science.gov (United States)

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical.

  18. Axial blanket for 16NGF Angra 1 fuel type

    Energy Technology Data Exchange (ETDEWEB)

    Sadde, Luciano Martins; Faria, Eduardo Fernandes [Industrias Nucleares do Brasil (INB), Resende, RJ (Brazil)]. E-mails: sadde@inb.gov.br; faria@inb.gov.br; Sang-Keun You [Korea Nuclear Fuel Co. Ltd. (KNFC), Taejon (Korea, Republic of)]. E-mail: skyou@knfc.co.kr

    2007-07-01

    Angra-1, Kori-2 and Krsko are nuclear power plants with the same design. However, the fuel assemblies have some differences in design due to the countries strategies and the differences in the fabrication process. The 16NGF (16x16 Next Generation Fuel) was developed by INB, KNFC and Westinghouse in order to be used in these three nuclear power plants and the 'Axial Blanket' is one of the new features for the 16NGF design. The main purpose of the Axial Blanket Optimization study is to determine which axial blanket enrichment and length would provide the better fuel cycle cost benefit. All of the calculations were performed using Gadolinium as Burnable Absorber and solid pellets type for Axial Blanket. The results indicate 1.8 w/o U235 enrichment and 8 inches length as the best option of Axial Blanket from the fuel cycle cost benefit standpoint. The economy is about 1.8%. The difference in the reload cost in the range between 1.5 and 2.6 w/o U235 enrichment and for the 6 and 8 inches length is not so significant. Due that, from the Fq limit standpoint and also for longer cycle length requirements, a higher axial blanket enrichment (2.6 w/o) and shorter length (6 inches) is recommended. (author)

  19. Axial design of nuclear fuel using path relinking; Diseno axial de combustible nuclear utilizando path relinking

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, A.; Torres, M.; Ortiz, J. J.; Perusquia, R.; Hernandez, J. L.; Montes, J. L. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: jacm@nuclear.inin.mx

    2008-07-01

    In the present work the preliminary results were obtained with the zoctli system whose purpose is the axial design of assembly of nuclear fuel under certain considerations. For the mentioned design well-know cells were already used and that they have been proven in diverse cycles of operation in the nuclear power plant of Laguna Verde. The design contemplates fuels assemblies of 10x10 and with 2 water channels. The assembly was distributed in 6 axial zones according to its structure. In order to take to end the optimization is was used the well-known technique like Path relinking and to find the group of previous solutions required by this technique uses the technical Taboo search. In order to work with Path relinking, 5 trajectories was taken in to account from a set of 5 previous solutions generated with theTaboo search, the update of the group of solutions is carried out in dynamic form. In the case of the Taboo search it was used a list of variable size, it was implement an aspiration approach, it was used the vector of frequencies and due to the cost of the evaluation of the objective function, only it was review 5% of the vicinity. For the objective function was considered the limit thermal, the axial profile of power, the effective multiplication factor and the margin of having turned off in cold. In order to prove the design system, it was used a balance cycle with a value of reference of 0.9928 for the effective multiplication factor that is equivalent to a produced energy of 10896 MWd/TU at the end of operation to full power. The designed assemblies were placed both in one of lots different from fresh assemblies on which it counts the referred cycle. At the end one a comparison with the results obtained with other techniques and under similar conditions is made. The results obtained until the moment show an appropriate performance of the system. It is possible to indicate that a small inconvenient is the amount of consumed resources of calculation during

  20. Neurovascular photoacoustic tomography

    Directory of Open Access Journals (Sweden)

    Song Hu

    2010-06-01

    Full Text Available Neurovascular coupling refers to the relationship between neuronal activities and downstream hemodynamic responses. Photoacoustic tomography (PAT, enabling comprehensive label-free imaging of hemodynamic activities with highly scalable penetration and spatial resolution, has great potential in the study of neurovascular coupling. In this review, we first introduce the technical basis of hemodynamic PAT—including label-free quantification of total hemoglobin concentration, blood oxygenation, and blood flow—as well as its applications in hemodynamic monitoring. Then, we demonstrate the potential application of PAT in neurovascular imaging by highlighting representative studies on cerebral vascular responses to whisker stimulation and Alzheimer’s disease. Finally, potential research directions and associated technical challenges are discussed.

  1. Forensic postmortem computed tomography

    DEFF Research Database (Denmark)

    Jakobsen, Lykke Schrøder; Lundemose, Sissel; Banner, Jytte

    2016-01-01

    PURPOSE: The purpose of this study was to investigate the utility of postmortem computed tomography (PMCT) images in estimating organ sizes and to examine the use of the cardiothoracic ratio (CTR). METHODS: We included 45 individuals (19 females), who underwent a medico-legal autopsy. Using...... the computer software program Mimics(®), we determined in situ heart and liver volumes derived from linear measurements (width, height and depth) on a whole body PMCT-scan, and compared the volumes with ex vivo volumes derived by CT-scan of the eviscerated heart and liver. The ex vivo volumes were also...... differences. CONCLUSIONS: Noninvasive in situ PMCT methods for organ measuring, as performed in this study, are not useful tools in forensic pathology. The best method to estimate organ volume is a CT-scan of the eviscerated organ. PMCT-determined CTR seems to be useless for ascertaining cardiomegaly...

  2. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Fercher, A.F.; Andersen, Peter E.

    2017-01-01

    Optical coherence tomography (OCT) is a technique that is used to peer inside a body noninvasively. Tissue structure defined by tissue absorption and scattering coefficients, and the speed of blood flow, are derived from the characteristics of light remitted by the body. Singly backscattered light...... used in the medical field, in particular, in ophthalmology. Owing to the high transmissivity of ocular media, the depth penetration is considerable. Corresponding applications in dermatology are somewhat hindered by the strong scattering of epidermic tissue (μs ≈ 102 mm−1). As OCT provides images...... for intraoperative monitoring, and in microsurgical intervention. Optical biopsy based on OCT also provides diagnostic information by differentiating the architectural morphology of urological tissue, gastrointestinal tissue, and respiratory tissue....

  3. 4-D Photoacoustic Tomography

    Science.gov (United States)

    Xiang, Liangzhong; Wang, Bo; Ji, Lijun; Jiang, Huabei

    2013-01-01

    Photoacoustic tomography (PAT) offers three-dimensional (3D) structural and functional imaging of living biological tissue with label-free, optical absorption contrast. These attributes lend PAT imaging to a wide variety of applications in clinical medicine and preclinical research. Despite advances in live animal imaging with PAT, there is still a need for 3D imaging at centimeter depths in real-time. We report the development of four dimensional (4D) PAT, which integrates time resolutions with 3D spatial resolution, obtained using spherical arrays of ultrasonic detectors. The 4D PAT technique generates motion pictures of imaged tissue, enabling real time tracking of dynamic physiological and pathological processes at hundred micrometer-millisecond resolutions. The 4D PAT technique is used here to image needle-based drug delivery and pharmacokinetics. We also use this technique to monitor 1) fast hemodynamic changes during inter-ictal epileptic seizures and 2) temperature variations during tumor thermal therapy.

  4. Structural examination of easel paintings with optical coherence tomography.

    Science.gov (United States)

    Targowski, Piotr; Iwanicka, Magdalena; Tymińska-Widmer, Ludmiła; Sylwestrzak, Marcin; Kwiatkowska, Ewa A

    2010-06-15

    Identification of the order, thickness, composition, and possibly the origin of the paint layers forming the structure of a painting, that is, its stratigraphy, is important in confirming its attribution and history as well as planning conservation treatments. The most common method of examination is analysis of a sample collected from the art object, both visually with a microscope and instrumentally through a variety of sophisticated, modern analytical tools. Because of its invasiveness, however, sampling is less than ideally compatible with conservation ethics; it is severely restricted with respect to the amount of material extirpated from the artwork. Sampling is also rather limited in that it provides only very local information. There is, therefore, a great need for a noninvasive method with sufficient in-depth resolution for resolving the stratigraphy of works of art. Optical coherence tomography (OCT) is a noninvasive, noncontact method of optical sectioning of partially transparent objects, with micrometer-level axial resolution. The method utilizes near-infrared light of low intensity (a few milliwatts) to obtain cross-sectional images of various objects; it has been mostly used in medical diagnostics. Through the serial collection of many such images, volume information may be extracted. The application of OCT to the examination of art objects has been in development since 2003. In this Account, we present a short introduction to the technique, briefly discuss the apparatus we use, and provide a paradigm for reading OCT tomograms. Unlike the majority of papers published previously, this Account focuses on one, very specific, use of OCT. We then consider two examples of successful, practical application of the technique. At the request of a conservation studio, the characteristics of inscriptions on two oil paintings, originating from the 18th and 19th centuries, were analyzed. In the first case, it was possible to resolve some questions concerning the

  5. Investigation of axial power gradients near a control rod tip

    Energy Technology Data Exchange (ETDEWEB)

    Loberg, John, E-mail: John.Loberg@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Osterlund, Michael, E-mail: Michael.Osterlund@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Bejmer, Klaes-Hakan, E-mail: Klaes-Hakan.Bejmer@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Blomgren, Jan, E-mail: Jan.Blomgren@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Kierkegaard, Jesper, E-mail: Jesper.Kierkegaar@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden)

    2011-07-15

    Highlights: > Pin power gradients near BWR control rod tips have been investigated. > A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. > Small nodes increases pin power gradients; standard nodes underestimates gradients. > The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, {approx}15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  6. Magnetic resonance tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.

    1985-12-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness.

  7. Shape Manifestation of Respiration in the Axial System

    Directory of Open Access Journals (Sweden)

    Eliška Slawiková

    2014-07-01

    Full Text Available Shape Manifestation of Respiration in the Axial System The aim of the study was to evaluate the effect of respiration on the shape changes of the axial system. Our approach focuses more on the analysis of respiratory function and their implementation within the complex axial system – the trunk. The results of this pilot study will use as evidence for further study of relationship between respiration and physiotherapy. Now we are looking for an answer to the question, at what level of the human body reflected the influence of respiration and its use in physiotherapy. This pilot study was attended by two women and one man aged 25–40 years, who were not selected for the study according to predetermined conditions. The same characteristic features of all three prarticipants were sedentary job connected with excessive mental strain, occasional low back pain (usually after a long sitting and the absence of acute or chronic respiratory diseases. Another common feature of the participants was the absence of structural changes in the spine. During the experiment was monitored maximum inhalation and maximum exhalation, and respiratory maneuver Kapalabhati, often used as one of the basic yoga breathing exercises. To detect trunk movement during the respiratory maneuver, we opted for a Qualysis – 3D torso topography. At the same time spirometer panned changes in volume over time, both exhaled and inhaled air. The purpose of this study was to assess symptoms and implementation of respiratory maneuvers in the axial system, particularly the chest and abdominal area. During the experiment, we followed the differences in reaction of the chest and abdomen in respiratory maneuver in the direction vertical, antero-posterior and lateral. The difference in these indicators at different phases of the respiratory maneuver confirms our assumption of the possibility of influencing the selected folders axial system through appropriately selected respiratory maneuver

  8. Axial length as a risk factor to branch retinal vein occlusion

    NARCIS (Netherlands)

    Timmerman, EA; deLavalette, VWR; vandenBrom, HJB

    1997-01-01

    Purpose: To determine whether axial length is a factor in branch retinal vein occlusion. Methods: Axial length measurements in a group of 24 patients with a unilateral branch retinal Vein occlusion were compared with the axial length measurements in a control group. axial length measurements were ta

  9. An appraisal of golimumab in the treatment of severe, active nonradiographic axial spondyloarthritis

    Directory of Open Access Journals (Sweden)

    Paccou J

    2016-07-01

    Full Text Available Julien Paccou, René-Marc Flipo Department of Rheumatology, Lille University Hospital, Lille, France Abstract: Golimumab (Simponi® is a fully human tumor necrosis factor α inhibitor (TNFi antibody administered subcutaneously. In the European Union, golimumab is indicated for the treatment of adults with severe, active axial spondyloarthritis (axSpA, which includes both ankylosing spondylitis (AS and nonradiographic axSpA (nr-axSpA. In the US, it is indicated for the treatment of adults with active AS only. This article reviews the efficacy and tolerability of golimumab in nr-axSpA patients compared to other TNFi agents (adalimumab, infliximab, etanercept, and certolizumab pegol. In one ongoing, well-designed controlled study (GO-AHEAD, data at 16 weeks showed that treatment with golimumab (50 mg every 4 weeks was effective in improving the clinical signs and symptoms of disease in nr-axSpA patients. In addition, 16 weeks of treatment with golimumab reduced inflammation in the sacroiliac joints and spine in patients with nr-axSpA. Moreover, objective evidence of active inflammation at baseline, such as a positive magnetic resonance imaging scan and/or an elevated CRP level, was a good predictor of treatment response to golimumab. Golimumab was generally well tolerated in this study, with a tolerability profile consistent with that seen in previous clinical trials for other indications. Although additional long-term data are needed, current evidence indicates that golimumab is an effective option for the treatment of nr-axSpA. However, in the absence of comparative head-to-head trials, there is no recommended hierarchy for the first prescription of a TNFi agent for the treatment of either nr-axSpA or AS. Keywords: axial spondyloarthritis, nonradiographic axial spondyloarthritis, ankylosing spondylitis, golimumab, tumor necrosis factor α inhibitor, therapy

  10. Improving resolution of optical coherence tomography for imaging of microstructures

    Science.gov (United States)

    Shen, Kai; Lu, Hui; Wang, James H.; Wang, Michael R.

    2015-03-01

    Multi-frame superresolution technique has been used to improve the lateral resolution of spectral domain optical coherence tomography (SD-OCT) for imaging of 3D microstructures. By adjusting the voltages applied to ? and ? galvanometer scanners in the measurement arm, small lateral imaging positional shifts have been introduced among different C-scans. Utilizing the extracted ?-? plane en face image frames from these specially offset C-scan image sets at the same axial position, we have reconstructed the lateral high resolution image by the efficient multi-frame superresolution technique. To further improve the image quality, we applied the latest K-SVD and bilateral total variation denoising algorithms to the raw SD-OCT lateral images before and along with the superresolution processing, respectively. The performance of the SD-OCT of improved lateral resolution is demonstrated by 3D imaging a microstructure fabricated by photolithography and a double-layer microfluidic device.

  11. Rhesus monkey brain imaging through intact skull with thermoacoustic tomography.

    Science.gov (United States)

    Xu, Yuan; Wang, Lihong V

    2006-03-01

    Two-dimensional microwave-induced thermoacoustic tomography (TAT) is applied to imaging the Rhesus monkey brain through the intact skull. To reduce the wavefront distortion caused by the skull, only the low-frequency components of the thermoacoustic signals (images. The methods of signal processing and image reconstruction are validated by imaging a lamb kidney. The resolution of the system is found to be 4 mm when we image a 1-month-old monkey head containing inserted needles. We also image the coronal and axial sections of a 7-month-old monkey head. Brain features that are 3 cm deep in the head are imaged clearly. Our results demonstrate that TAT has potential for use in portable, cost-effective imagers for pediatric brains.

  12. Imaging port wine stains by fiber optical coherence tomography

    Science.gov (United States)

    Zhao, Shiyong; Gu, Ying; Xue, Ping; Guo, Jin; Shen, Tingmei; Wang, Tianshi; Huang, Naiyan; Zhang, Li; Qiu, Haixia; Yu, Xin; Wei, Xunbin

    2010-05-01

    We develop a fiber optical coherence tomography (OCT) system in the clinical utility of imaging port wine stains (PWS). We use our OCT system on 41 patients with PWS to document the difference between PWS skin and contralateral normal skin. The system, which operates at 4 frames/s with axial and transverse resolutions of 10 and 9 μm, respectively, in the skin tissue, can clearly distinguish the dilated dermal blood vessels from normal tissue. We present OCT images of patients with PWS and normal human skin. We obtain the structural parameters, including epidermal thickness and diameter and depth of dilated blood vessels. We demonstrate that OCT may be a useful tool for the noninvasive imaging of PWS. It may help determine the photosensitizer dose and laser parameters in photodynamic therapy for treating port wine stains.

  13. Development and Testing of an Axial Halbach Magnetic Bearing

    Science.gov (United States)

    Eichenberg, Dennis J.; Gallo, Christopher A.; Thompson, William K.

    2006-01-01

    The NASA Glenn Research Center has developed and tested a revolutionary Axial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic thrust bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Axial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Axial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical systems, computer memory systems, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Axial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability.

  14. Design and Simulation of Axial Flow Maglev Blood Pump

    Directory of Open Access Journals (Sweden)

    Huachun Wu

    2011-03-01

    Full Text Available The axial flow maglev blood pump (AFMBP has become a global research focus and emphasis for artificial ventricular assist device, which has no mechanical contact, mechanical friction, compact structure and light weight, can effectively solve thrombus and hemolysis. Magnetic suspension and impeller is two of the important parts in the axial flow maglev blood pump, and their structure largely determines the blood pump performance. The research adopts electromagnetic and fluid finite element analysis, and puts forward a method to design the magnetic suspension and impeller of axial flow blood pump, which tacks into account the small volume of axial blood pump. The magnetic bearing’s characteristics are evaluated by electromagnetic finite element analysis. The Blades have been designed by calculating aerofoil bone line, and make simulation analysis for different thicken ways of blade by Fluent software, and make a conclusion that the blade thickened with certain rules has better characteristics in the same conditions. The results will provide some guidance for design of axial flow maglev blood pump, and establish theoretical basis for application of the implantable artificial heart pump.

  15. Light Weakly Coupled Axial Forces: Models, Constraints, and Projections

    CERN Document Server

    Kahn, Yonatan; Mishra-Sharma, Siddharth; Tait, Tim M P

    2016-01-01

    We investigate the landscape of constraints on MeV-GeV scale, hidden U(1) forces with nonzero axial-vector couplings to Standard Model fermions. While the purely vector-coupled dark photon, which may arise from kinetic mixing, is a well-motivated scenario, several MeV-scale anomalies motivate a theory with axial couplings which can be UV-completed consistent with Standard Model gauge invariance. Moreover, existing constraints on dark photons depend on products of various combinations of axial and vector couplings, making it difficult to isolate the effects of axial couplings for particular flavors of SM fermions. We present a representative renormalizable, UV-complete model of a dark photon with adjustable axial and vector couplings, discuss its general features, and show how some UV constraints may be relaxed in a model with nonrenormalizable Yukawa couplings at the expense of fine-tuning. We survey the existing parameter space and the projected reach of planned experiments, briefly commenting on the relevan...

  16. Amphiregulin Antibody and Reduction of Axial Elongation in Experimental Myopia

    Directory of Open Access Journals (Sweden)

    Wen Jun Jiang

    2017-03-01

    Full Text Available To examine the mechanism of ocular axial elongation in myopia, guinea pigs (age: 2–3 weeks which either underwent unilateral or bilateral lens-induced myopization (group 1 or which were primarily myopic at baseline (group 2 received unilateral intraocular injections of amphiregulin antibody (doses: 5, 10, or 15 μg three times in intervals of 9 days. A third group of emmetropic guinea pigs got intraocular unilateral injections of amphiregulin (doses: 0.25, 0.50 or 1.00 ng, respectively. In each group, the contralateral eyes received intraocular injections of Ringer's solution. In intra-animal inter-eye comparison and intra-eye follow-up comparison in groups 1 and 2, the study eyes as compared to the contralateral eyes showed a dose-dependent reduction in axial elongation. In group 3, study eyes and control eyes did not differ significantly in axial elongation. Immunohistochemistry revealed amphiregulin labelling at the retinal pigment epithelium in eyes with lens-induced myopization and Ringer's solution injection, but not in eyes with amphiregulin antibody injection. Intraocular injections of amphiregulin-antibody led to a reduction of lens-induced axial myopic elongation and of the physiological eye enlargement in young guinea pigs. In contrast, intraocularly injected amphiregulin in a dose of ≤1 ng did not show a significant effect. Amphiregulin may be one of several essential molecular factors for axial elongation.

  17. Axial clamp for nuclear reactor head penetration conoseal joints

    Energy Technology Data Exchange (ETDEWEB)

    Hackley, T.A.

    1987-03-31

    A method is described for forming a sealed coupling between two bodies, each body presenting an annular abutment surface. The respective bodies are arranged so that their respective annular abutment surfaces are axially adjacent one another, defining a space therebetween, wherein a deformable gasket is disposed within the space. The method comprises: providing one of the bodies with an annular projection; providing the other body with threads for receiving an annular locknut which can be tightened to bear against the annular projection of the one body; applying an external axial forced to the bodies for compressing the abutment surfaces together against the gasket to form a seal between the bodies; immobilizing the bodies relative to one another while the external force is being applied to the bodies by hand-tightening an annular locknut via the threads of the other body until the locknut abuts the annular projection of the one body, substantially preventing relative axial movement between the bodies when the external axial force is withdrawn; and withdrawing the external axial force applied to the bodies, leaving the two bodies coupled together via the seal.

  18. An Axial-Vector Photon in a Mirror World

    Science.gov (United States)

    Sharafiddinov, Rasulkhozha S.

    2016-03-01

    The unity of symmetry laws emphasizes, in the case of a mirror CP-even Dirac Lagrangian, the ideas of the left- and right-handed axial-vector photons referring to long- and short-lived bosons of true neutrality, respectively. Such a difference in lifetimes expresses the unidenticality of masses, energies and momenta of axial-vector photons of the different components. They define the unified field theory equation of C-odd particles with an integral spin. Together with a new equation of a theory of truly neutral particles with the half-integral spin, the latter reflects the availability in their nature of the second type of the local axial-vector gauge transformation responsible for origination in the Lagrangian of C-oddity of an interaction Newton component giving an axial-vector mass to all the interacting particles and fields. The mirror axial-vector mass, energy and momentum operators constitute a CP-invariant equation of quantum mechanics, confirming that each of them can individually influence on matter field. Thereby, findings suggest at the level of the mass-charge structure of gauge invariance a new equation for the C-noninvariant Lagrangian.

  19. Light Weakly Coupled Axial Forces: Models, Constraints, and Projections

    Energy Technology Data Exchange (ETDEWEB)

    Kahn, Yonatan [Princeton U.; Krnjaic, Gordan [Fermilab; Mishra-Sharma, Siddharth [Princeton U.; Tait, Tim P. [UC, Irvine

    2016-09-28

    We investigate the landscape of constraints on MeV-GeV scale, hidden U(1) forces with nonzero axial-vector couplings to Standard Model fermions. While the purely vector-coupled dark photon, which may arise from kinetic mixing, is a well-motivated scenario, several MeV-scale anomalies motivate a theory with axial couplings which can be UV-completed consistent with Standard Model gauge invariance. Moreover, existing constraints on dark photons depend on products of various combinations of axial and vector couplings, making it difficult to isolate the effects of axial couplings for particular flavors of SM fermions. We present a representative renormalizable, UV-complete model of a dark photon with adjustable axial and vector couplings, discuss its general features, and show how some UV constraints may be relaxed in a model with nonrenormalizable Yukawa couplings at the expense of fine-tuning. We survey the existing parameter space and the projected reach of planned experiments, briefly commenting on the relevance of the allowed parameter space to low-energy anomalies in pi^0 and 8-Be* decay.

  20. Method to measure tone of axial and proximal muscle.

    Science.gov (United States)

    Gurfinkel, Victor S; Cacciatore, Timothy W; Cordo, Paul J; Horak, Fay B

    2011-12-14

    The control of tonic muscular activity remains poorly understood. While abnormal tone is commonly assessed clinically by measuring the passive resistance of relaxed limbs, no systems are available to study tonic muscle control in a natural, active state of antigravity support. We have developed a device (Twister) to study tonic regulation of axial and proximal muscles during active postural maintenance (i.e. postural tone). Twister rotates axial body regions relative to each other about the vertical axis during stance, so as to twist the neck, trunk or hip regions. This twisting imposes length changes on axial muscles without changing the body's relationship to gravity. Because Twister does not provide postural support, tone must be regulated to counteract gravitational torques. We quantify this tonic regulation by the restive torque to twisting, which reflects the state of all muscles undergoing length changes, as well as by electromyography of relevant muscles. Because tone is characterized by long-lasting low-level muscle activity, tonic control is studied with slow movements that produce "tonic" changes in muscle length, without evoking fast "phasic" responses. Twister can be reconfigured to study various aspects of muscle tone, such as co-contraction, tonic modulation to postural changes, tonic interactions across body segments, as well as perceptual thresholds to slow axial rotation. Twister can also be used to provide a quantitative measurement of the effects of disease on axial and proximal postural tone and assess the efficacy of intervention.

  1. An Axial Vector Photon in a Mirror World

    CERN Document Server

    Sharafiddinov, Rasulkhozha S

    2015-01-01

    The unity of symmetry laws emphasizes, in the case of a mirror CP-even Dirac Lagrangian, the ideas of the left- and right-handed axial-vector photons referring to long- and short-lived bosons of true neutrality, respectively. Such a difference in lifetimes expresses the unidenticality of masses, energies and momenta of axial-vector photons of the different components. They define the unified field theory equation of C-odd particles with an integral spin. Together with a new equation of a theory of truly neutral particles with the half-integral spin, the latter reflects the availability in their nature of the second type of the local axial-vector gauge transformation responsible for origination in the Lagrangian of C-oddity of an interaction Newton component giving an axial-vector mass to all the interacting particles and fields. The mirror axial-vector mass, energy and momentum operators constitute a CP-invariant equation of quantum mechanics, confirming that each of them can individually influence on matter ...

  2. Fluoroscopic lumbar interlaminar epidural injections in managing chronic lumbar axial or discogenic pain

    Directory of Open Access Journals (Sweden)

    Manchikanti L

    2012-08-01

    Full Text Available Laxmaiah Manchikanti,1,2 Kimberly A Cash,1 Carla D McManus,1 Vidyasagar Pampati,1 Ramsin Benyamin3,41Pain Management Center of Paducah, Paducah, KY; 2University of Louisville, Louisville, KY; 3Millennium Pain Center, Bloomington, IL; 4University of Illinois, Urbana-Champaign, IL, USAAbstract: Among the multiple causes of chronic low back pain, axial and discogenic pain are common. Various modalities of treatments are utilized in managing discogenic and axial low back pain including epidural injections. However, there is a paucity of evidence regarding the effectiveness, indications, and medical necessity of any treatment modality utilized for managing axial or discogenic pain, including epidural injections. In an interventional pain management practice in the US, a randomized, double-blind, active control trial was conducted. The objective was to assess the effectiveness of lumbar interlaminar epidural injections of local anesthetic with or without steroids for managing chronic low back pain of discogenic origin. However, disc herniation, radiculitis, facet joint pain, or sacroiliac joint pain were excluded. Two groups of patients were studied, with 60 patients in each group receiving either local anesthetic only or local anesthetic mixed with non-particulate betamethasone. Primary outcome measures included the pain relief-assessed by numeric rating scale of pain and functional status assessed by the, Oswestry Disability Index, Secondary outcome measurements included employment status, and opioid intake. Significant improvement or success was defined as at least a 50% decrease in pain and disability. Significant improvement was seen in 77% of the patients in Group I and 67% of the patients in Group II. In the successful groups (those with at least 3 weeks of relief with the first two procedures, the improvement was 84% in Group I and 71% in Group II. For those with chronic function-limiting low back pain refractory to conservative management

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... materials and a metallic taste in his/her mouth that lasts for a few minutes. Occasionally, a ...

  4. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...

  5. Electrical Impedance Tomography Technology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Electrical Impendance Tomography (EIT) utilizes a series of electrodes in a circumferential band-like device feeding these signals to a portable computer that...

  6. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  7. Interventional video tomography

    Science.gov (United States)

    Truppe, Michael J.; Pongracz, Ferenc; Ploder, Oliver; Wagner, Arne; Ewers, Rolf

    1995-05-01

    Interventional Video Tomography (IVT) is a new imaging modality for Image Directed Surgery to visualize in real-time intraoperatively the spatial position of surgical instruments relative to the patient's anatomy. The video imaging detector is based on a special camera equipped with an optical viewing and lighting system and electronic 3D sensors. When combined with an endoscope it is used for examining the inside of cavities or hollow organs of the body from many different angles. The surface topography of objects is reconstructed from a sequence of monocular video or endoscopic images. To increase accuracy and speed of the reconstruction the relative movement between objects and endoscope is continuously tracked by electronic sensors. The IVT image sequence represents a 4D data set in stereotactic space and contains image, surface topography and motion data. In ENT surgery an IVT image sequence of the planned and so far accessible surgical path is acquired prior to surgery. To simulate the surgical procedure the cross sectional imaging data is superimposed with the digitally stored IVT image sequence. During surgery the video sequence component of the IVT simulation is substituted by the live video source. The IVT technology makes obsolete the use of 3D digitizing probes for the patient image coordinate transformation. The image fusion of medical imaging data with live video sources is the first practical use of augmented reality in medicine. During surgery a head-up display is used to overlay real-time reformatted cross sectional imaging data with the live video image.

  8. Solar tomography adaptive optics.

    Science.gov (United States)

    Ren, Deqing; Zhu, Yongtian; Zhang, Xi; Dou, Jiangpei; Zhao, Gang

    2014-03-10

    Conventional solar adaptive optics uses one deformable mirror (DM) and one guide star for wave-front sensing, which seriously limits high-resolution imaging over a large field of view (FOV). Recent progress toward multiconjugate adaptive optics indicates that atmosphere turbulence induced wave-front distortion at different altitudes can be reconstructed by using multiple guide stars. To maximize the performance over a large FOV, we propose a solar tomography adaptive optics (TAO) system that uses tomographic wave-front information and uses one DM. We show that by fully taking advantage of the knowledge of three-dimensional wave-front distribution, a classical solar adaptive optics with one DM can provide an extra performance gain for high-resolution imaging over a large FOV in the near infrared. The TAO will allow existing one-deformable-mirror solar adaptive optics to deliver better performance over a large FOV for high-resolution magnetic field investigation, where solar activities occur in a two-dimensional field up to 60'', and where the near infrared is superior to the visible in terms of magnetic field sensitivity.

  9. Multiphoton tomography of astronauts

    Science.gov (United States)

    König, Karsten; Weinigel, Martin; Pietruszka, Anna; Bückle, Rainer; Gerlach, Nicole; Heinrich, Ulrike

    2015-03-01

    Weightlessness may impair the astronaut's health conditions. Skin impairments belong to the most frequent health problems during space missions. Within the Skin B project, skin physiological changes during long duration space flights are currently investigated on three European astronauts that work for nearly half a year at the ISS. Measurements on the hydration, the transepidermal water loss, the surface structure, elasticity and the tissue density by ultrasound are conducted. Furthermore, high-resolution in vivo histology is performed by multiphoton tomography with 300 nm spatial and 200 ps temporal resolution. The mobile certified medical tomograph with a flexible 360° scan head attached to a mechano-optical arm is employed to measure two-photon autofluorescence and SHG in the volar forearm of the astronauts. Modification of the tissue architecture and of the fluorescent biomolecules NAD(P)H, keratin, melanin and elastin are detected as well as of SHG-active collagen. Thinning of the vital epidermis, a decrease of the autofluoresence intensity, an increase in the long fluorescence lifetime, and a reduced skin ageing index SAAID based on an increased collagen level in the upper dermis have been found. Current studies focus on recovery effects.

  10. Fast dual tomography

    Science.gov (United States)

    Carrion, Philip M.

    1990-09-01

    This paper can be considered as a continuation of the work by Carrion and Carneiro (1989), where a generalized approach to linearized inversion of geophysical data was developed. Their method allows one to incorporate virtually any constraints in the inversion and reformulate the problem in the dual space of Langrangian multipliers (see also Carrion, 1989a). The constrained tomography makes traveltime inversion robust: it automatically rejects “bad data” which correspond to solutions beyond the chosen constraints and allows one to start inversion with an arbitrary chosen initial model.In this paper, I will derive basic formulas for constrained tomographic imaging that can be used in such areas of geophysics as global mapping of the earth interior, exploration geophysics, etc. The method is fast: an example that will be shown in the paper took only 6 min. of VAX CPU time. Had the conventional least-squares matrix inversion been used it would have taken more than 10 hours of the CPU time to solve the same problem.

  11. Fast dual tomography

    Energy Technology Data Exchange (ETDEWEB)

    Carrion, P.M. (PPPG/UFBA - Campus Universitario da Federacao, Salvador-Bahia (Brazil))

    1990-09-01

    This paper can be considered as a continuation of the work by Carrion and Carneiro (1989), where a generalized approach to linearized inversion of geophysical data was developed. Their method allows one to incorporate virtually any constraints in the inversion and reformulate the problem in the dual space of Langrangian multipliers (see also Carrion, 1989a). The constrained tomography makes traveltime inversion robust: it automatically rejects bad data which correspond to solutions beyond the chosen constraints and allows one to start inversion with an arbitrary chosen initial model. In this paper, the author derives basic formulas for constrained tomographic imaging that can be used in such areas of geophysics as global mapping of the earth interior, exploration geophysics, etc. The method is fast: an example that will be shown in the paper took only 6 min. of VAX CPU time. Had the conventional least-squares matrix inversion been used it would have taken more than 10 hours of the CPU time to solve the same problem.

  12. Dynamic Behavior of Axially Functionally Graded Pipes Conveying Fluid

    Directory of Open Access Journals (Sweden)

    Chen An

    2017-01-01

    Full Text Available Dynamic behavior of axially functionally graded (FG pipes conveying fluid was investigated numerically by using the generalized integral transform technique (GITT. The transverse vibration equation was integral transformed into a coupled system of second-order differential equations in the temporal variable. The Mathematica’s built-in function, NDSolve, was employed to numerically solve the resulting transformed ODE system. Excellent convergence of the proposed eigenfunction expansions was demonstrated for calculating the transverse displacement at various points of axially FG pipes conveying fluid. The proposed approach was verified by comparing the obtained results with the available solutions reported in the literature. Moreover, parametric studies were performed to analyze the effects of Young’s modulus variation, material distribution, and flow velocity on the dynamic behavior of axially FG pipes conveying fluid.

  13. Liquid Axial Mixing in Packed Tower at Elevated Pressure

    Institute of Scientific and Technical Information of China (English)

    唐忠利; 张鹏; 等

    2003-01-01

    Liquid phase axial mixing was measured with the tracer technique in a packed column with inner diameter of 0.15m,in which the structured packing,Mellapak 350Y,was installed.Tap water as the liquid phase flowed down through the column and stagnant gas was at elevated pressure ranging from atmospheric to 2.0MPa.The model parameters of Bo andθwere estimated with the least square method in the time domain.As liquid flow rate was increased,the liquid axial mixing decreased.under our experimental conditions,the effect of pressure on Bo number on single liquid phase was negligible,and eddy diffusion was believed to be the primary cause of axial mixing in liquid phase.

  14. Unsteady cooperative flow type in the axial compressor

    Institute of Scientific and Technical Information of China (English)

    ZHENG Xinqian; ZHOU Sheng; HOU Anping; XIONG Jinsong

    2005-01-01

    For increasing the performance of the axial compressor, a method for realizing unsteady cooperative flow type is proposed in this paper as a critical objective in the new generation of the axial compressor design system. Unsteady excitations were utilized to trigger the transformation from the unsteady natural flow pattern into the unsteady cooperative flow pattern, resulting in increment of aerodynamic performances of axial compressor. Numerical simulations show that distinct positive effect can be obtained for the 2D cascade in a wide range of subsonic working conditions. No positive effect can be observed under the 2D supersonic working conditions and unsteady excitations have little influence on the flow field space-time structure. However, positive effect can be obtained under the 3D transsonic working conditions. In addition, engineering applications of unsteady cooperative flow type are discussed.

  15. Investigation of Aluminum-Copper Tube Hydroforming with Axial Feeding

    Science.gov (United States)

    Parto D., M.; Seyedkashi, S. M. H.; Liaghat, Gh.; Naeini, H. Moslemi; Panahizadeh R., V.

    2011-01-01

    Hydroforming of a two-layered Aluminum-Copper tube is investigated numerically and experimentally. Pressure is applied through a nonlinear path along with symmetrical axial feeding. ABAQUS/Explicit commercial code is used for finite element simulation of the process. ASTM C11000 Copper alloy is used as inner layer and ASTM AA1050A Aluminum alloy is used as outer layer. The simulation results show that the part can be successfully formed under internal pressure of 40 MPa with 8 mm axial displacement. Stress distributions on both inner and outer tubes are compared and maximum thinning on their wall is also discussed. Different friction conditions are applied on the process using different coefficients of friction and their effects are investigated on thinning percentage of inner and outer tubes and also on axial feeding. It is observed that finite element results are in good agreement with experimental results.

  16. Numerical analysis of cavitation within slanted axial-flow pump

    Institute of Scientific and Technical Information of China (English)

    张睿; 陈红勋

    2013-01-01

    In this paper, the cavitating flow within a slanted axial-flow pump is numerically researched. The hydraulic and cavitation performance of the slanted axial-flow pump under different operation conditions are estimated. Compared with the experimental hydraulic performance curves, the numerical results show that the filter-based model is better than the standard k-e model to predict the parameters of hydraulic performance. In cavitation simulation, compared with the experimental results, the proposed numerical method has good predicting ability. Under different cavitation conditions, the internal cavitating flow fields within slanted axial-flow pump are investigated. Compared with flow visualization results, the major internal flow features can be effectively grasped. In order to explore the origin of the cavitation performance breakdown, the Boundary Vorticity Flux (BVF) is introduced to diagnose the cavitating flow fields. The analysis results indicate that the cavitation performance drop is relevant to the instability of cavitating flow on the blade suction surface.

  17. Bistability between equatorial and axial dipoles during magnetic field reversals

    CERN Document Server

    Gissinger, Christophe; Schrinner, Martin; Dormy, Emmanuel

    2012-01-01

    Numerical simulations of the geodynamo in presence of an heterogeneous heating are presented. We study the dynamics and the structure of the magnetic field when the equatorial symmetry of the flow is broken. If the symmetry breaking is sufficiently strong, the m = 0 axial dipolar field is replaced by an hemispherical magnetic field, dominated by an oscillating m = 1 magnetic field. Moreover, for moderate symmetry breaking, a bistability between the axial and the equatorial dipole is observed. In this bistable regime, the axial magnetic field exhibits chaotic switches of its polarity, involving the equatorial dipole during the transition period. This new scenario for magnetic field reversals is discussed within the framework of the Earth's dynamo.

  18. Bistability between equatorial and axial dipoles during magnetic field reversals.

    Science.gov (United States)

    Gissinger, Christophe; Petitdemange, Ludovic; Schrinner, Martin; Dormy, Emmanuel

    2012-06-08

    Numerical simulations of the geodynamo in the presence of heterogeneous heating are presented. We study the dynamics and the structure of the magnetic field when the equatorial symmetry of the flow is broken. If the symmetry breaking is sufficiently strong, the m=0 axial dipolar field is replaced by a hemispherical magnetic field, dominated by an oscillating m=1 magnetic field. Moreover, for moderate symmetry breaking, a bistability between the axial and the equatorial dipole is observed. In this bistable regime, the axial magnetic field exhibits chaotic switches of its polarity, involving the equatorial dipole during the transition period. This new scenario for magnetic field reversals is discussed within the framework of Earth's dynamo.

  19. Depth Compensated Spectral Domain Optical Coherence Tomography via Digital Compensation

    CERN Document Server

    Boroomand, Ameneh; Shafiee, Mohammad Javad; Bizheva, Kostadinka; Wong, Alexander

    2015-01-01

    Spectral Domain Optical Coherence Tomography (SD-OCT) is a well-known imaging modality which allows for \\textit{in-vivo} visualization of the morphology of different biological tissues at cellular level resolutions. The overall SD-OCT imaging quality in terms of axial resolution and Signal-to-Noise Ratio (SNR) degrades with imaging depth, while the lateral resolution degrades with distance from the focal plane. This image quality degradation is due both to the design of the SD-OCT imaging system and the optical properties of the imaged object. Here, we present a novel Depth Compensated SD-OCT (DC-OCT) system that integrates a Depth Compensating Digital Signal Processing (DC-DSP) module to improve the overall imaging quality via digital compensation. The designed DC-DSP module can be integrated to any SD-OCT system and is able to simultaneously compensate for the depth-dependent loss of axial and lateral resolutions, depth-varying SNR, as well as sidelobe artifact for improved imaging quality. The integrated D...

  20. Bone changes of mandibular condyle using cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Un; Kim, Hyung Seop; Song, Ju Seop; Kim, Kyoung A; Koh, Kwang Joon [Chonbuk National Univ., Chonju (Korea, Republic of)

    2007-09-15

    To assess bone changes of mandibular condyle using cone beam computed tomography (CBCT) in temporomandibualr disorder (TMD) patients. 314 temporomandibular joints (TMJs) images of 163 TMD patients were examined at the Department of Oral and Maxillofacial Radiology, Chonbuk National University. The images were obtained by PSR9000N (Asahi Roentgen Co., Japan) and reconstructed by using Asahivision software (Asahi Roentgen Co., Japan). The CBCT images were examined three times with four weeks interval by three radiologists. Bone changes of mandibular condyle such as flattening, sclerosis, erosion and osteophyte formation were observed in sagittal, axial, coronal and 3 dimensional images of the mandibular condyle. The statistical analysis was performed using SPSS 12.0. Intra-and interobserver agreement were performed by 3 radiologists without the knowledge of clinical information. Osteopathy (2.9%) was found more frequently on anterior surface of the mandibular condyle. Erosion (31.8%) was found more frequently on anterior surface of the mandibular condyle. The intraobserver agreement was good to excellent (k=0.78{sub 0}.84), but interobserver agreement was fair (k=0.45). CBCT can provide high qualified images of bone changes of the TMJ with axial, coronal and 3 dimensional images.

  1. Oblique reconstruction of the cruciate ligaments on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Hidetoshi; Nishino, Koshi; Koga, Masayuki; Kitakata, Akira; Deya, Keizo; Nakagawa, Hiroto

    1984-12-01

    Optimal positioning where the entire longitudinal axis of the cruciate ligaments could be demonstrated on computed tomography was discovered by using an amputated knee and was applied clinically. To demonstrate the anterior cruciate ligament, the patient was positioned on the table with the hip flexed, abducted, externally rotated and knee flexed at a 110-140 degrees angle. For the posterior cruciate ligament, the patient was placed in a prone position on the table with the knee flexed at a 50 degrees angle. These positions, especially the one for the anterior cruciate ligament, were difficult for some patients with gonalgia or limited range of motion. Reconstruction in the oblique planes was studied for those patients by using an amputated knee and quasi-ligament made of gum. Clinically, an axial image was obtained by the simple position of the patient lying prone on the table with knee extended. Oblique reconstruction was made from the axial images and this reconstructed image also demonstrated the entire longitudinal axis of the ligament. The rupture of the cruciate ligaments could be assessed by the reconstructed image in the oblique plane. (author).

  2. Regional brain axial and radial diffusivity changes during development.

    Science.gov (United States)

    Kumar, Rajesh; Nguyen, Haidang D; Macey, Paul M; Woo, Mary A; Harper, Ronald M

    2012-02-01

    The developing human brain shows rapid myelination and axonal changes during childhood, adolescence, and early adulthood, requiring successive evaluations to determine normative values for potential pathological assessment. Fiber characteristics can be examined by axial and radial diffusivity procedures, which measure water diffusion parallel and perpendicular to axons and show primarily axonal status and myelin changes, respectively. Such measures are lacking from widespread sites for the developing brain. Diffusion tensor imaging data were acquired from 30 healthy subjects (age 17.7 ± 4.6 years, range 8-24 years, body mass index 21.5 ± 4.5 kg/m(2), 18 males) using a 3.0-Tesla MRI scanner. Diffusion tensors were calculated, principal eigenvalues determined, and axial and radial diffusivity maps calculated and normalized to a common space. A set of regions of interest was outlined from widespread brain areas within rostral, thalamic, hypothalamic, cerebellar, and pontine regions, and average diffusivity values were calculated using normalized diffusivity maps and these regions of interest masks. Age-related changes were assessed with Pearson's correlations, and gender differences evaluated with Student's t-tests. Axial and radial diffusivity values declined with age in the majority of brain areas, except for midhippocampus, where axial diffusivity values correlated positively with age. Gender differences emerged within putamen, thalamic, hypothalamic, cerebellar, limbic, temporal, and other cortical sites. Documentation of normal axial and radial diffusivity values will help assess disease-related tissue changes. Axial and radial diffusivities change with age,with fiber structure and organization differing between sexes in several brain areas. The findings may underlie gender-based functional characteristics, and mandate partitioning age- and gender-related changes during developmental brain pathology evaluation.

  3. Seismic attenuation tomography in frequency domain and its application to engineering

    Institute of Scientific and Technical Information of China (English)

    赵永贵[1; 李勤[2; 郭鸿[3; 靳洪晓[4; 王超凡[5

    2000-01-01

    Seismic tomography is a new geophysical technique being developed to meet the needs of mining and engineering projects. Attenuation tomography, as one kind of seismic tomography technique, is a powerful prospecting tool for determining structure defaults such as fault, broken zone, and hidden voids, but it has been little discussed up to now. Its principle and applications are presented in detail. Attenuation tomography technology includes the following main points. First, on the basis of spectrum analysis to each seismic record, geometric correction is conducted, then common source parameters are introduced into common shot records in order to keep absorption effect of the geological media separate from source spectrum influence. Finally, an equation set is obtained which consists of absorption coefficients, common source parameters and energy field data observed. This technique can be employed together with velocity tomography to provide more evidence for engineering and geological diagnosis. Its appl

  4. Seismic attenuation tomography in frequency domain and its application to engineering

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Seismic tomography is a new geophysical technique being developed to meet the needs of mining and engineering projects. Attenuation tomography, as one kind of seismic tomography technique, is a powerful prospecting tool for determining structure defaults such as fault, broken zone, and hidden voids, but it has been little discussed up to now. Its principle and applications are presented in detail. Attenuation tomography technology includes the following main points. First, on the basis of spectrum analysis to each seismic record, geometric correction is conducted, then common source parameters are introduced into common shot records in order to keep absorption effect of the geological media separate from source spectrum influence. Finally, an equation set is obtained which consists of absorption coefficients, common source parameters and energy field data observed. This technique can be employed together with velocity tomography to provide more evidence for engineering and geological diagnosis. Its applications to exploration of mineral and engineering have led to satisfactory results.

  5. The axial topographic high at intermediate and fast spreading ridges

    Science.gov (United States)

    Carbotte, Suzanne M.; MacDonald, Ken C.

    1994-12-01

    An axial topographic high is commonly observed at both fast spreading ridges and some segments of intermediate spreading ridges. At fast rates the axial high is primarily created by the buoyancy of hot rock and magma beneath the rise. As newly formed crust is transported off axis, little vestige of an axial high is observed on the ridge flanks. In contrast, at intermediate rates, a significant component of the positive topography may be a volcanic construction, preserved on the ridge flanks as abyssal hills, which are slit axial volcanoes. We suggest this difference in the nature of the axial high reflects a lithosphere strong enough to support construction of a volcanic crestal ridge at intermediate spreading rates, but only rarely at fast rates. Relict overlap ridges, found within the discordant zones left by overlapping spreading centers, is one class of ridge-flank topography which appears to have a significant volcanic constructional component even at fast spreading ridges. Unlike topography away from these discontinuities, the relief and shape of overlapping spreading centers is preserved as relict ridge tips are rafted onto the ridge flanks. Reduced magma supply at these discontinuities may give rise to an axial lithosphere strong enough to support volcanic construction of overlap ridges. Low axial lithospheric strength may also account for the lack of normal faults within the innermost 1-2 km of fast, and some intermediate, spreading ridges. With a thin/weak brittle layer at the ridge crest, tensile failure will predominate and few normal faults will form. Depths to the axial magma chamber reflector observed in multi-channel seismic data limit the thickness of the brittel layer on axis to less than 1-2 km for much of the East Pacific Rise (EPR). This depth is comparable to depths over which tensile failure within the oceanic crust will predominate, estimated from the Griffith criteria for fracture initiation (approx. 0.5-1.5 km). As the brittle layer

  6. Recent Results on High-Pressure Axial Blowers

    Science.gov (United States)

    Eckert, B.

    1947-01-01

    Considerable progress has, in recent times, been attained in the development of the high-pressure axial blower by well-planned research. The efforts are directed toward improving the efficiencies, which are already high for the axial blower, and in particular the delivery pressure heads. For high pressures multistage arrangements are used. Of fundamental importance is the careful design of all structural parts of the blower that are subject to the effects of the flow. In the present report, several recent results and experiences are reported, which are based on results of German engine research.

  7. The seismic design of axial blower using Ansys

    Energy Technology Data Exchange (ETDEWEB)

    Im, Hyung Bin; Kim, Kang Sung; Heo, Jin Wook; Chung, Jin Tai [Hanyang Univ., Seoul (Korea, Republic of)

    2001-07-01

    The seismic design for an axial blower is the procedure in which the Required Response Spectrum(RRS) is computed by using the Floor Response Spectrum(FRS). The seismic design is very important to reduce severe damages from an earthquake; therefore, the seismic design has been a great concern in engineering society. In this study, after finite element modeling is established by using Ansys, the modal data are obtained such as the natural frequencies, the participation factor, and so on. With these data, the RRS is acquired by a numerical approach. The seismic safety of the axial blower is evaluated.

  8. Fermion decoupling and the axial anomaly on the lattice

    CERN Document Server

    Banerjee, H; De, Asit K.

    1999-01-01

    By an explicit calculation of the continuum limit of the triangle graph amplitude in lattice QED we show that in the axial Ward identity the ABJ anomaly exactly cancels the pseudoscalar density term in the limit of infinite fermion mass $m$. The result, a reflection of decoupling of the heavy fermion, provides a convenient framework for computing the flavor-singlet or U(1) axial anomaly in non-Abelian gauge theories on lattice. Our calculations on the lattice are performed using Wilson fermions but the results are general.

  9. Vector and Axial Currents in Wilson Chiral Perturbation Theory

    CERN Document Server

    Aoki, Sinya; Sharpe, Stephen R

    2009-01-01

    We reconsider the construction of the vector and axial-vector currents in Wilson Chiral Perturbation Theory (WChPT), the low-energy effective theory for lattice QCD with Wilson fermions. We discuss in detail the finite renormalization of the currents that has to be taken into account in order to properly match the currents. We explicitly show that imposing the chiral Ward identities on the currents does, in general, affect the axial-vector current at O(a). As an application of our results we compute the pion decay constant to one loop in the two flavor theory. Our result differs from previously published ones.

  10. Self-collimated axial jets from thin accretion disks

    CERN Document Server

    Tirabassi, Giulio; Carlevaro, Nakia; Benini, Riccardo

    2012-01-01

    We show how an appropriate stationary crystalline structure of the magnetic field can induce a partial fragmentation of the accretion disk, generating an axial jet composed of hot rising plasma twisted in a funnel-like structure by the rotation of the system. The most important feature of the obtained jet is its high degree of collimation, naturally arising from the condition for its existence. The presence of non-zero dissipative effects allows the plasma ejection throughout the axial jet and the predicted values of the accretion rate are in agreement with observations.

  11. An effective theory for QCD with an axial chemical potential

    CERN Document Server

    Andrianov, Alexander A; Espriu, Domenec; Planells, Xumeu

    2013-01-01

    We consider the low energy realization of QCD in terms of meson fields when an axial chemical potential is present; a situation that may be relevant in heavy ion collisions. We shall demonstrate that the presence of an axial charge constitutes an explicit source of parity breaking. The eigenstates of strong interactions do not have a definite parity and interactions that would otherwise be forbidden compete with the familiar ones. In this work, we first focus on scalars and pseudoscalars that are described by a generalized linear sigma model; and next, we give some hints on how the Vector Meson Dominance model describes the vector sector.

  12. Instability of Meridional Axial System in f(R) Gravity

    CERN Document Server

    Sharif, M

    2015-01-01

    We analyze dynamical instability of non-static reflection axial stellar structure by taking into account generalized Euler's equation in metric $f(R)$ gravity. Such an equation is obtained by contracting Bianchi identities of usual anisotropic and effective stress-energy tensors, which after using radial perturbation technique gives modified collapse equation. In the realm of $R+\\epsilon R^n$ gravity model, we investigate instability constraints at Newtonian and post-Newtonian approximations. We find that instability of meridional axial self-gravitating system depends upon static profile of structure coefficients while $f(R)$ extra curvature terms induce stability to the evolving celestial body.

  13. Spectral analysis in thin tubes with axial heterogeneities

    KAUST Repository

    Ferreira, Rita

    2015-01-01

    In this paper, we present the 3D-1D asymptotic analysis of the Dirichlet spectral problem associated with an elliptic operator with axial periodic heterogeneities. We extend to the 3D-1D case previous 3D-2D results (see [10]) and we analyze the special case where the scale of thickness is much smaller than the scale of the heterogeneities and the planar coefficient has a unique global minimum in the periodic cell. These results are of great relevance in the comprehension of the wave propagation in nanowires showing axial heterogeneities (see [17]).

  14. En-face optical coherence tomography revival

    Science.gov (United States)

    Bradu, Adrian; Kapinchev, Konstantin; Barnes, Frederick; Podoleanu, Adrian Gh.

    2016-03-01

    Quite recently, we introduced a novel Optical Coherence Tomography (OCT) method, termed as Master Slave OCT (MS-OCT), especially to deliver en-face images. MS-OCT operates like a time domain OCT, selecting signal from a selected depth only while scanning the laser beam across the sample. Time domain OCT allows real time production of an en-face image, although relatively slowly. As a major advance, the Master Slave method allows collection of signals from any number of depths, as required by the user. MS-OCT is an OCT method that does not require resampling of data and can be used to deliver en-face images from several depths simultaneously. However, as the MS-OCT method requires important computational resources, the number of multiple depth en-face images produced in real-time is limited. Here, we demonstrate that taking advantage of the parallel processing feature of the MS-OCT technology by harnessing the capabilities of graphics processing units (GPU)s, information from 384 depth positions is acquired in one raster with real time display of 40 en-face OCT images. These exhibit comparable resolution and sensitivity to the images produced using the traditional Fourier domain based method. The GPU facilitates versatile real time selection of parameters, such as the depth positions of the 40 images out of a set of 384 depth locations, as well as their axial resolution. Here, we present in parallel with the 40 en-face OCT images of a human tooth, a confocal microscopy lookalike image, together with two B-scan OCT images along rectangular directions.

  15. Carious growth monitoring with optical coherence tomography

    Science.gov (United States)

    Freitas, A. Z.; Zezell, D. M.; Mayer, M. P. A.; Ribeiro, A. C.; Gomes, A. S. L.; Vieira, N. D., Jr.

    2006-02-01

    Optical Coherence Tomography was used to monitor subsurface caries evolution process in vitro. Human tooth was used and bacteria were employed to induce caries lesions. Twenty-five human third molars, were used in this study. The teeth were cut longitudinally at mesio-distal direction; the surfaces were coated with nail varnish except for two squared windows (2x4 mm); at the cement-enamel junction. Artificial lesions were induced by a S. Mutans microbiological culture. The samples (N = 50) were divided into groups according to the demineralization time: 3, 5, 7, 9 and 11 days. The culture medium, was changed each 48 hours. After the demineralization process the samples were rinsed with double-deionized water and stored in a humid environment. The OCT system was implemented with average power of 96 μW in the sample arm, providing a 23 μm of axial resolution. The images were produced with lateral scans step of 10 μm. The detection system was composed by a detector, a demodulator and a computer. With the images generated by OCT it was possible to determine the lesion depth as function of sample exposition time to microbiological culture. We observed that the depth of the lesion in the root dentine increased from 70 μm to 230 μm, depending of exposure time, and follows the bacterial population growth law. This OCT system accurately depicts hard dental tissue and it was able to detect early caries in its structure, providing a powerful contactless high resolution image of lesions.

  16. Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gaia, Bruno Felipe [University of Sao Paulo (USP), SP (Brazil). Dental School. Stomatology Dept.; Sales, Marcelo Augusto Oliveira de [University of Paraiba (UFPB), Joao Pessoa, PB (Brazil). Dental School. Dept. of Radiology; Perrella, Andreia; Fenyo-Pereira, Marlene; Cavalcanti, Marcelo Gusmao Paraiso, E-mail: mgpcaval@usp.b [University of Sao Paulo (USP), SP (Brazil). Dental School. Dept. of Radiology

    2011-07-15

    There are many studies that compare the accuracy of multislice (MSCT) and cone beam (CBCT) computed tomography for evaluations in the maxillofacial region. However, further studies comparing both acquisition techniques for the evaluation of simulated mandibular bone lesions are needed. The aim of this study was to compare the accuracy of MSCT and CBCT in the diagnosis of simulated mandibular bone lesions by means of cross sectional images and axial/MPR slices. Lesions with different dimensions, shape and locularity were produced in 15 dry mandibles. The images were obtained following the cross sectional and axial/MPR (Multiplanar Reconstruction) imaging protocols and were interpreted independently. CBCT and MSCT showed similar results in depicting the percentage of cortical bone involvement, with great sensitivity and specificity (p < 0.005). There were no significant intra- or inter-examiner differences between axial/MPR images and cross sectional images with regard to sensitivity and specificity. CBCT showed results similar to those of MSCT for the identification of the number of simulated bone lesions. Cross sectional slices and axial/MPR images presented high accuracy, proving useful for bone lesion diagnosis. (author)

  17. Doppler optical coherence microscopy and tomography applied to inner ear mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Page, Scott; Freeman, Dennis M. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Ghaffari, Roozbeh [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States)

    2015-12-31

    While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

  18. Optical Coherence Tomography

    Science.gov (United States)

    Huang, David

    Optical coherence tomography (OCT) is a new method for noninvasive cross-sectional imaging in biological systems. In OCT, the longitudinal locations of tissue structures are determined by measuring the time-of-flight delays of light backscattered from these structures. The optical delays are measured by low coherence interferometry. Information on lateral position is provided by transverse scanning of the probe beam. The two dimensional map of optical scattering from internal tissue microstructures is then represented in a false-color or grayscale image. OCT is the optical analog of ultrasonic pulse-echo imaging, but with greatly improved spatial resolutions (a few microns). This thesis describes the development of this new high resolution tomographic imaging technology and the demonstration of its use in a variety of tissues under both in vitro and in vivo conditions. In vitro OCT ranging and imaging studies were performed using human ocular and arterial tissues, two clinically relevant examples of transparent and turbid media, respectively. In the anterior eye, precise measurements of cornea and anterior chamber dimensions were made. In the arterial specimens, the differentiation between fatty -calcified and fibromuscular tissues was demonstrated. In vivo OCT imaging in the retina and optic nerve head in human subjects was also performed. The delineation of retinal layers, which has not been possible with other noninvasive imaging techniques, is demonstrated in these OCT images. OCT has high spatial resolution but limited penetration into turbid tissue. It has potential for diagnostic applications where high resolution is needed and optical access is available, such as in the eye, skin, surgically exposed tissues, and surfaces that can be reached by various catheters and endoscopic probes. In particular, the measurement of fine retinal structures promises improvements in the diagnosis and management of glaucoma, macular edema and other vitreo-retinal diseases

  19. Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Pier Alberto Testoni

    2007-01-01

    Full Text Available Optical coherence tomography (OCT is an optical imaging modality that performs high-resolution, cross-sectional, subsurface tomographic imaging of the microstructure of tissues. The physical principle of OCT is similar to that of B-mode ultrasound imaging, except that it uses infrared light waves rather than acoustic waves. The in vivo resolution is 10–25 times better (about 10 µm than with high-frequency ultrasound imaging, but the depth of penetration is limited to 1–3 mm, depending on tissue structure, depth of focus of the probe used, and pressure applied to the tissue surface. In the last decade, OCT technology has evolved from an experimental laboratory tool to a new diagnostic imaging modality with a wide spectrum of clinical applications in medical practice, including the gastrointestinal tract and pancreatico-biliary ductal system. OCT imaging from the gastrointestinal tract can be done in humans by using narrow-diameter, catheter-based probes that can be inserted through the accessory channel of either a conventional front-view endoscope, for investigating the epithelial structure of the gastrointestinal tract, or a side-view endoscope, inside a standard transparent ERCP (endoscopic retrograde cholangiopancreatography catheter, for investigating the pancreatico-biliary ductal system. The esophagus and esophagogastric junction have been the most widely investigated organs so far; more recently, duodenum, colon, and the pancreatico-biliary ductal system have also been extensively investigated. OCT imaging of the gastrointestinal wall structure is characterized by a multiple-layer architecture that permits an accurate evaluation of the mucosa, lamina propria, muscularis mucosae, and part of the submucosa. The technique may therefore be used to identify preneoplastic conditions of the gastrointestinal tract, such as Barrett's epithelium and dysplasia, and evaluate the depth of penetration of early-stage neoplastic lesions. OCT imaging

  20. Dynamic response of the occipito-atlanto-axial (C0-C1-C2) complex in right axial rotation.

    Science.gov (United States)

    Chang, H; Gilbertson, L G; Goel, V K; Winterbottom, J M; Clark, C R; Patwardhan, A

    1992-05-01

    The torque-angular deformation in right axial rotation until failure of the ligamentous occipito-atlanto-axial complex subjected to variable loading rate (dynamic) axial torque was characterized using a biaxial MTS system. A special fixture and gear box that permitted right axial rotation of the specimen until failure without imposing any additional constraints were used to obtain the data. The specimens were divided into three groups and tested until failure at three different dynamic loading rates: 50, 100, and 400 degrees/s. A previous study by the authors provided data for quasi-static (4 degrees/s) loading conditions. The torque versus rotation curves can be divided into two straight regions and two transition zones. The plots clearly indicated that at loading rates higher than 4 degrees/s, the specimens became stiffer in the region of steadily increasing resistance prior to failure. The increase in stiffness was maximum at 100 degrees/s. The stiffness decreased somewhat at 400 degrees/s in comparison with 100 degrees/s, but this decrease was not significant. The resulting torque-right axial rotation curves were also examined to estimate the magnitude of maximum resistance (torque) and the corresponding angular rotation value. The average maximum resistance torque increased from 13.6 Nm at 4 degrees/s to 27.8 Nm at 100 degrees/s. The corresponding right angular rotation data (65-78 degrees), however, did not show any significant variation with loading rate. Posttest dissection of the specimens indicated that the type of injury observed was related to the rate of axial loading imposed on a specimen during testing.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Quantitative analysis of cholesteatoma using high resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Shigeru; Yamasoba, Tatsuya (Kameda General Hospital, Chiba (Japan)); Iinuma, Toshitaka

    1992-05-01

    Seventy-three cases of adult cholesteatoma, including 52 cases of pars flaccida type cholesteatoma and 21 of pars tensa type cholesteatoma, were examined using high resolution computed tomography, in both axial (lateral semicircular canal plane) and coronal sections (cochlear, vestibular and antral plane). These cases were classified into two subtypes according to the presence of extension of cholesteatoma into the antrum. Sixty cases of chronic otitis media with central perforation (COM) were also examined as controls. Various locations of the middle ear cavity were measured in terms of size in comparison with pars flaccida type cholesteatoma, pars tensa type cholesteatoma and COM. The width of the attic was significantly larger in both pars flaccida type and pars tensa type cholesteatoma than in COM. With pars flaccida type cholesteatoma there was a significantly larger distance between the malleus and lateral wall of the attic than with COM. In contrast, the distance between the malleus and medial wall of the attic was significantly larger with pars tensa type cholesteatoma than with COM. With cholesteatoma extending into the antrum, regardless of the type of cholesteatoma, there were significantly larger distances than with COM at the following sites: the width and height of the aditus ad antrum, and the width, height and anterior-posterior diameter of the antrum. However, these distances were not significantly different between cholesteatoma without extension into the antrum and COM. The hitherto demonstrated qualitative impressions of bone destruction in cholesteatoma were quantitatively verified in detail using high resolution computed tomography. (author).

  2. Positron Emission Tomography with Three-Dimensional Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of `mobile pixels`, which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs.

  3. Computed tomography findings of paracoccidiodomycosis in musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Francisco Valtenor Araujo; Savarese, Leonor Garbin; Monsignore, Lucas Moretti; Martinez, Roberto; Nogueira-Barbosa, Marcello Henrique, E-mail: fvaltenor@gmail.com [Universidade de Sao Paulo (FM/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina

    2015-01-15

    Objective: to evaluate musculoskeletal involvement in paracoccidioidomycosis at computed tomography. Materials and methods: development of a retrospective study based on a review of radiologic and pathologic reports in the institution database. Patients with histopathologically confirmed musculoskeletal paracoccidioidomycosis and submitted to computed tomography were included in the present study. The imaging findings were consensually described by two radiologists. In order to avoid bias in the analysis, one patient with uncountable bone lesions was excluded from the study. Results: a total of seven patients were included in the present study. A total of 18 bone lesions were counted. The study group consisted of 7 patients. A total number of 18 bone lesions were counted. Osteoarticular lesions were the first manifestation of the disease in four patients (57.14%). Bone lesions were multiple in 42.85% of patients. Appendicular and axial skeleton were affected in 85.71% and 42.85% of cases, respectively. Bone involvement was characterized by well-demarcated osteolytic lesions. Marginal osteosclerosis was identified in 72.22% of the lesions, while lamellar periosteal reaction and soft tissue component were present in 5.55% of them. One patient showed multiple small lesions with bone sequestra. Conclusion: paracoccidioidomycosis can be included in the differential diagnosis of either single or multiple osteolytic lesions in young patients even in the absence of a previous diagnosis of pulmonary or visceral paracoccidioidomycosis. (author)

  4. Use of cone beam computed tomography in periodontology.

    Science.gov (United States)

    Acar, Buket; Kamburoğlu, Kıvanç

    2014-05-28

    Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography (CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  5. Fourier phase in Fourier-domain optical coherence tomography.

    Science.gov (United States)

    Uttam, Shikhar; Liu, Yang

    2015-12-01

    Phase of an electromagnetic wave propagating through a sample-of-interest is well understood in the context of quantitative phase imaging in transmission-mode microscopy. In the past decade, Fourier-domain optical coherence tomography has been used to extend quantitative phase imaging to the reflection-mode. Unlike transmission-mode electromagnetic phase, however, the origin and characteristics of reflection-mode Fourier phase are poorly understood, especially in samples with a slowly varying refractive index. In this paper, the general theory of Fourier phase from first principles is presented, and it is shown that Fourier phase is a joint estimate of subresolution offset and mean spatial frequency of the coherence-gated sample refractive index. It is also shown that both spectral-domain phase microscopy and depth-resolved spatial-domain low-coherence quantitative phase microscopy are special cases of this general theory. Analytical expressions are provided for both, and simulations are presented to explain and support the theoretical results. These results are further used to show how Fourier phase allows the estimation of an axial mean spatial frequency profile of the sample, along with depth-resolved characterization of localized optical density change and sample heterogeneity. Finally, a Fourier phase-based explanation of Doppler optical coherence tomography is also provided.

  6. Multi-axial mechanical stimulation of tissue engineered cartilage: Review

    Directory of Open Access Journals (Sweden)

    S D Waldman

    2007-04-01

    Full Text Available The development of tissue engineered cartilage is a promising new approach for the repair of damaged or diseased tissue. Since it has proven difficult to generate cartilaginous tissue with properties similar to that of native articular cartilage, several studies have used mechanical stimuli as a means to improve the quantity and quality of the developed tissue. In this study, we have investigated the effect of multi-axial loading applied during in vitro tissue formation to better reflect the physiological forces that chondrocytes are subjected to in vivo. Dynamic combined compression-shear stimulation (5% compression and 5% shear strain amplitudes increased both collagen and proteoglycan synthesis (76 ± 8% and 73 ± 5%, respectively over the static (unstimulated controls. When this multi-axial loading condition was applied to the chondrocyte cultures over a four week period, there were significant improvements in both extracellular matrix (ECM accumulation and the mechanical properties of the in vitro-formed tissue (3-fold increase in compressive modulus and 1.75-fold increase in shear modulus. Stimulated tissues were also significantly thinner than the static controls (19% reduction suggesting that there was a degree of ECM consolidation as a result of long-term multi-axial loading. This study demonstrated that stimulation by multi-axial forces can improve the quality of the in vitro-formed tissue, but additional studies are required to further optimize the conditions to favour improved biochemical and mechanical properties of the developed tissue.

  7. Optimal design of multi-conditions for axial flow pump

    Science.gov (United States)

    Shi, L. J.; Tang, F. P.; Liu, C.; Xie, R. S.; Zhang, W. P.

    2016-11-01

    Passage components of the pump device will have a negative flow state when axial pump run off the design condition. Combined with model tests of axial flow pump, this paper use numerical simulation and numerical optimization techniques, and change geometric design parameters of the impeller to optimal design of multi conditions for Axial Flow Pump, in order to improve the efficiency of non-design conditions, broad the high efficient district and reduce operating cost. The results show that, efficiency curve of optimized significantly wider than the initial one without optimization. The efficiency of low flow working point increased by about 2.6%, the designed working point increased by about 0.5%, and the high flow working point increased the most, about 7.4%. The change range of head is small, so all working point can meet the operational requirements. That will greatly reduce operating costs and shorten the period of optimal design. This paper adopted the CFD simulation as the subject analysis, combined with experiment study, instead of artificial way of optimization design with experience, which proves the reliability and efficiency of the optimization design of multi-operation conditions of axial-flow pump device.

  8. FINITE ELEMENT ANALYSIS OF AXIAL FEED BAR ROLLING

    Institute of Scientific and Technical Information of China (English)

    C.G. Xu; G.H. Liu; G.S. Ren; Z. Shen; C.P. Ma; W. W. Ren

    2007-01-01

    A flexible technique of hot working of bars by axial feed rolling was introduced. The processdeformation, strain field, stress field, and temperature field of the parts are analyzed by finite elementmethod (FEM)-simulation software DEFORM-3D. The material flow rule and tool load have beeninvestigated.

  9. 3-D Simulation of Vertical-Axial Tidal Current Turbine

    Directory of Open Access Journals (Sweden)

    Zhiyang Zhang

    2016-12-01

    Full Text Available Vertical-axial tidal current turbine is the key for the energy converter, which has the advantages of simple structure, adaptability to flow and uncomplex convection device. It has become the hot point for research and application recently. At present, the study on the hydrodynamic performance of vertical-axial tidal current turbine is almost on 2-D numerical simulation, without the consideration of 3-D effect. CFD (Computational Fluid Dynamics method and blade optimal control technique are used to improve accuracy in the prediction of tidal current turbine hydrodynamic performance. Numerical simulation of vertical-axial tidal current turbine is validated. Fixed and variable deflection angle turbine are comparatively studied to analysis the influence of 3-D effect and the character of fluid field and pressure field. The method, put the plate on the end of blade, of reduce the energy loss caused by 3-D effect is proposed. The 3-D CFD numerical model of vertical-axial tidal current turbine hydrodynamic performance in this study may provide theoretical, methodical and technical reference for the optimal design of turbine.

  10. On aspects of vibration of axially moving continua

    NARCIS (Netherlands)

    Hageraats-Ponomareva, S.

    2009-01-01

    In axially moving structures like conveyor belt systems, magnetic tapes, and so on, vibrations occur due to the presence of different kinds of imperfections in the systems. For these structures internal resonances can lead to severe vibrations. Resonance free conveyor belt systems can be constructed

  11. Dynamic Behaviors of Axially Moving Viscoelastic Plate with Varying Thicknessn

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yinfeng; WANG Zhongmin

    2009-01-01

    Structural components of varying thickness draw increasing attention these days due to economy and light-weight considerations. In view of the absence of research in vibration analysis of viscoelastic plate with varying thickness, this study devotes to investigate the dynamic behaviors of axially moving viscoelastic plate with varying thickness. Based on the thin plate theory and the two-dimensional viscoelastic differential constitutive relation, the differential equation of motion of the axially moving viscoelastic rectangular plate is derived, the plate constituted by Kelvin-Voigt model has linearly varying thickness in the y-direction. The dimensionless complex frequencies of axially moving viscoelastic plate with four edges simply supported are calculated by the differential quadrature method, curves of real parts and imaginary parts of the first three-order dimensionless complex frequencies versus dimensionless moving speed are obtained, the effects of the aspect ratio, thickness ratio, the dimensionless moving speed and delay time on the dynamic behaviors of the axially moving viscoelastic rectangular plate with varying thickness are analyzed. When other parameters keep constant, with the decrease of thickness ratio, the real parts of the first three-order natural frequencies decrease, and the critical divergence speeds of various modes decrease too, moreover, whether the delay time is large or small, the frequencies are all complex numbers.

  12. View of the Axial Field Spectrometer (R807)

    CERN Multimedia

    1980-01-01

    In this view of the Axial Field Spectrometer at I8, the vertical uranium/scintillator hadron calorimeter (just left of centre) is retracted to give access to the cylindrical central drift chamber. The yellow iron structure served as a filter to identify muons, with MWPCs and the array of Cherenkov counters to the right.

  13. Axially and spherically symmetric solitons in warm plasma

    CERN Document Server

    Dvornikov, Maxim

    2010-01-01

    We study the existence of stable axially and spherically symmetric plasma structures on the basis of the new nonlinear Schrodinger equation (NLSE) accounting for nonlocal electron nonlinearities. The numerical solutions of NLSE having the form of spatial solitions are obtained and their stability is analyzed. We discuss the possible application of the obtained results to the theoretical description of natural plasmoids in the atmosphere.

  14. An axially symmetric solution of metric-affine gravity

    CERN Document Server

    Vlachynsky, E J; Obukhov, Yu N; Hehl, F W

    1996-01-01

    We present an exact stationary {\\it axially symmetric} vacuum solution of metric-affine gravity (MAG) which generalises the recently reported spherically symmetric solution. Besides the metric, it carries nonmetricity and torsion as post-Riemannian geometrical structures. The parameters of the solution are interpreted as mass and angular momentum and as dilation, shear and spin charges.

  15. Further comment on pion electroproduction and the axial form factor

    CERN Document Server

    Bernard, V; Meißner, Ulf G; Mei{\\ss}ner, Ulf-G.

    2001-01-01

    We show that a recent claim (H.Haberzettl, Phys. Rev. Lett. 85 (2000) 3576) that one cannot extract the nucleon weak axial form factor G_A (t) from charged pion threshold electroproduction is incorrect. Thus previous calculations remain valid and threshold charged pion electroproduction experiments can indeed be used to determine G_A (t), and they should certainly be pursued.

  16. The cause of axial rotation of the scoliotic spine

    NARCIS (Netherlands)

    Lemmers, L.G.; Sanders, M.M.; Cool, J.C.; Grootenboer, H.J.

    1991-01-01

    To explain the cause of axial rotation in a scoliotic vertebral column, the influence of the gravitation force on a spine with a C-scoliosis has been investigated by means of a mechanical model. In this model the gravitation force takes hold of the three-dimensionally curved vertebral column eccentr

  17. On the generation techniques of axially symmetric stationary metrics

    Indian Academy of Sciences (India)

    S Chaudhuri

    2002-03-01

    In the present paper, a relationship between the method of Gutsunaev–Manko and the soliton technique (for two-soliton solutions) of Belinskii–Zakharov, for generating solutions of axially symmetric stationary space-times in general relativity is discussed.

  18. Numerical Study of Axial Turbulent Flow Over Long Cylinders

    Science.gov (United States)

    1992-04-01

    DATAV [NZ/2, MTH, 3, MR] and as DATAP[NZ/2, MTH, MR], respectively. The first index indicates the axial (streamwise) wave number I = 1, ... , NZ/2...MTH + 12, 12 !5 MTH/2, -[(THGR -1) *MTH + 12- MTH/2], I2> MTH/2. The third index in DATAV indicates the velocity component according to/3 = 3 (1 -4 V

  19. Chondrocyte activity is increased in psoriatic arthritis and axial spondyloarthritis

    DEFF Research Database (Denmark)

    Gudmann, Natasja Stæhr; Munk, Heidi Lausten; Christensen, Anne Friesgaard

    2016-01-01

    BACKGROUND: Psoriatic arthritis (PsA) and axial spondyloarthritis (axSpA) are chronic inflammatory rheumatic diseases with complex origins. Both are characterized by altered extracellular matrix remodeling in joints and entheses that results in destructive and osteochondral proliferative lesions...

  20. Etanercept for the treatment of non-radiographic axial spondyloarthritis.

    Science.gov (United States)

    Rios Rodriguez, Valeria; Poddubnyy, Denis

    2016-01-01

    Presently, tumor necrosis factor α antagonist therapy is the only effective alternative treatment to nonsteroidal anti-inflammatory drugs for the entire spectrum of axial spondyloarthritis, including non-radiographic and radiographic (=ankylosing spondylitis) forms. Recently, etanercept has been approved by the European Medicines Agency for the treatment of non-radiographic axial spondyloarthritis, increasing the number of available treatment options for this indication. The latest data on etanercept concerning clinical efficacy and safety in short-term and long-term treatment of patients with non-radiographic axial spondyloarthritis who do not respond to the first-line therapy with non-steroidal anti-inflammatory drugs suggests good efficacy and safety profiles similar to that observed previously in ankylosing spondylitis. This article reviews recent data on the efficacy and safety of etanercept and is focused on the treatment of non-radiographic axial spondyloarthritis. This article will also discuss the role of etanercept in the context of current and developing treatment options.

  1. A cylindrical drift chamber with azimuthal and axial position readout

    Energy Technology Data Exchange (ETDEWEB)

    Bar-Yam, Z.; Cummings, J.P.; Dowd, J.P.; Eugenio, P.; Hayek, M.; Kern, W.; King, E.; Shenhav, N.; Chung, S.U.; Hackenburg, R.W.; Olchanski, C.; Weygand, D.P.; Willutzki, H.J.; Brabson, B.B.; Crittenden, R.R.; Dzierba, A.R.; Gunter, J.; Lindenbusch, R.; Rust, D.R.; Scott, E.; Smith, P.T.; Sulanke, T.; Teige, S.; Denisov, S.; Dushkin, A.; Kochetkov, V.; Lipaev, V.; Popov, A.; Shein, I.; Soldatov, A.; Anoshina, E.V.; Bodyagin, V.A.; Demianov, A.I.; Gribushin, A.M.; Kodolova, O.L.; Korotkikh, V.L.; Kostin, M.A.; Ostrovidov, A.I.; Sarycheva, L.I.; Sinev, N.B.; Vardanyan, I.N.; Yershov, A.A.; Adams, T.; Bishop, J.M.; Cason, N.M.; Sanjari, A.H.; LoSecco, J.M.; Manak, J.J.; Shephard, W.D.; Stienike, D.L.; Taegar, S.A.; Thompson, D.R.; Brown, D.S.; Pedlar, T.; Seth, K.K.; Wise, J.; Zhao, D.; Adams, G.S.; Napolitano, J.; Nozar, M.; Smith, J.A.; Witkowski, M. [Massachusetts Univ., North Dartmouth, MA (United States)]|[Brookhaven National Laboratory, Upton, L.I., NY 11973 (United States)]|[Indiana University, Bloomington, IN 47405 (United States)]|[Institute for High Energy Physics, Protvino (Russian Federation)]|[Institute of Nuclear Physics, Moscow State University, Moscow (Russian Federation)]|[University of Notre Dame, Notre Dame, IN 46556 (United States)]|[Northwestern University, Evanston, IL 60208 (United States)]|[Rensselaer Polytechnic Institute, Troy, NY 12180 (United States)

    1997-02-21

    A cylindrical multiwire drift chamber with axial charge-division has been constructed and used in experiment E852 at Brookhaven National Laboratory. It serves as a trigger element and as a tracking device for recoil protons in {pi}{sup -}p interactions. We describe the chamber`s design considerations, details of its construction, electronics, and performance characteristics. (orig.).

  2. Spiral thickenings in the axial Parenchyma of Chrysobalanaceae

    NARCIS (Netherlands)

    Welle, ter B.J.H.

    1976-01-01

    Spiral thickenings in the axial parenchyma, seldom recorded in the secondary xylem of the dicotyledons so far, are described for a number of genera and/or species of Chrysobalanaceae. In 66 out of 99 samples investigated, representing most genera of the Chrysobalanaceae, spiral thickenings proved to

  3. Static Tension Tests on Axially Loaded Pile Segments in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    This paper provides laboratory test results of static axially loaded piles in sand. With a newly developed test setup, the pile-soil interface friction was investigated by using an open-ended steel pile segment with a diameter of 0.5 m. Use of a pile length of 1 m enabled the pile-soil interface...

  4. On the Applications of Axial Representation of Trigonometric Functions

    Science.gov (United States)

    Siadat, M. Vali

    2006-01-01

    In terms of modern pedagogy, having visual interpretation of trigonometric functions is useful and quite helpful. This paper presents, pictorially, an easy approach to prove all single angle trigonometric identities on the axes. It also discusses the application of axial representation in calculus--finding the derivative of trigonometric functions.

  5. Observers in spacetimes with spherical and axial symmetries

    OpenAIRE

    Gusin, Pawel; Kusnierz, Bartosz; Radosz, Andrzej

    2015-01-01

    We introduce in the explicit form the tetrads of arbitrary observers in spacetimes with spherical and axial symmetries. The observers confined to the equatorial plane are parametrized by the pair of functions. We apply this description in the analysis of the null-geodesics in the observers' frames. The observers with the constant acceleration are distinguished.

  6. Periodicity effects of axial waves in elastic compound rods

    DEFF Research Database (Denmark)

    Nielsen, R. B.; Sorokin, S. V.

    2015-01-01

    Floquet analysis is applied to the Bernoulli-Euler model for axial waves in a periodic rod. Explicit asymptotic formulae for the stop band borders are given and the topology of the stop band pattern is explained. Eigenfrequencies of the symmetric unit cell are determined by the Phase-closure Prin...

  7. Axial dispersion in flowing red blood cell suspensions

    Science.gov (United States)

    Podgorski, Thomas; Losserand, Sylvain; Coupier, Gwennou

    2016-11-01

    A key parameter in blood microcirculation is the transit time of red blood cells (RBCs) through an organ, which can influence the efficiency of gas exchange and oxygen availability. A large dispersion of this transit time is observed in vivo and is partly due to the axial dispersion in the flowing suspension. In the classic Taylor-Aris example of a solute flowing in a tube, the combination of molecular diffusion and parabolic velocity profile leads to enhanced axial dispersion. In suspensions of non-Brownian deformable bodies such as RBCs, axial dispersion is governed by a combination of shear induced migration and shear-induced diffusion arising from hydrodynamic interactions. We revisit this problem in the case of RBC pulses flowing in a microchannel and show that the axial dispersion of the pulse eventually saturates with a final extension that depends directly on RBC mechanical properties. The result is especially interesting in the dilute limit since the final pulse length depends only on the channel width, exponent of the migration law and dimensionless migration velocity. In continuous flow, the dispersion of transit times is the result of complex cell-cell and cell-wall interactions and is strongy influenced by the polydispersity of the blood sample. The authors acknowledge support from LabEx TEC21 and CNES.

  8. Fully automatic measurements of axial vertebral rotation for assessment of spinal deformity in idiopathic scoliosis

    Science.gov (United States)

    Forsberg, Daniel; Lundström, Claes; Andersson, Mats; Vavruch, Ludvig; Tropp, Hans; Knutsson, Hans

    2013-03-01

    Reliable measurements of spinal deformities in idiopathic scoliosis are vital, since they are used for assessing the degree of scoliosis, deciding upon treatment and monitoring the progression of the disease. However, commonly used two dimensional methods (e.g. the Cobb angle) do not fully capture the three dimensional deformity at hand in scoliosis, of which axial vertebral rotation (AVR) is considered to be of great importance. There are manual methods for measuring the AVR, but they are often time-consuming and related with a high intra- and inter-observer variability. In this paper, we present a fully automatic method for estimating the AVR in images from computed tomography. The proposed method is evaluated on four scoliotic patients with 17 vertebrae each and compared with manual measurements performed by three observers using the standard method by Aaro-Dahlborn. The comparison shows that the difference in measured AVR between automatic and manual measurements are on the same level as the inter-observer difference. This is further supported by a high intraclass correlation coefficient (0.971-0.979), obtained when comparing the automatic measurements with the manual measurements of each observer. Hence, the provided results and the computational performance, only requiring approximately 10 to 15 s for processing an entire volume, demonstrate the potential clinical value of the proposed method.

  9. Donor disc attachment assessment with intraoperative spectral optical coherence tomography during descemet stripping automated endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Edward Wylegala

    2013-01-01

    Full Text Available Optical coherence tomography has already been proven to be useful for pre- and post-surgical anterior eye segment assessment, especially in lamellar keratoplasty procedures. There is no evidence for intraoperative usefulness of optical coherence tomography (OCT. We present a case report of the intraoperative donor disc attachment assessment with spectral-domain optical coherence tomography in case of Descemet stripping automated endothelial keratoplasty (DSAEK surgery combined with corneal incisions. The effectiveness of the performed corneal stab incisions was visualized directly by OCT scan analysis. OCT assisted DSAEK allows the assessment of the accuracy of the Descemet stripping and donor disc attachment.

  10. Diffractive molecular-orbital tomography

    Science.gov (United States)

    Zhai, Chunyang; Zhu, Xiaosong; Lan, Pengfei; Wang, Feng; He, Lixin; Shi, Wenjing; Li, Yang; Li, Min; Zhang, Qingbin; Lu, Peixiang

    2017-03-01

    High-order-harmonic generation in the interaction of femtosecond lasers with atoms and molecules opens the path to molecular-orbital tomography and to probe the electronic dynamics with attosecond-Ångström resolutions. Molecular-orbital tomography requires both the amplitude and phase of the high-order harmonics. Yet the measurement of phases requires sophisticated techniques and represents formidable challenges at present. Here we report a scheme, called diffractive molecular-orbital tomography, to retrieve the molecular orbital solely from the amplitude of high-order harmonics without measuring any phase information. We have applied this method to image the molecular orbitals of N2, CO2, and C2H2 . The retrieved orbital is further improved by taking account the correction of Coulomb potential. The diffractive molecular-orbital tomography scheme, removing the roadblock of phase measurement, significantly simplifies the molecular-orbital tomography procedure and paves an efficient and robust way to the imaging of more complex molecules.

  11. Database tomography for commercial application

    Science.gov (United States)

    Kostoff, Ronald N.; Eberhart, Henry J.

    1994-01-01

    Database tomography is a method for extracting themes and their relationships from text. The algorithms, employed begin with word frequency and word proximity analysis and build upon these results. When the word 'database' is used, think of medical or police records, patents, journals, or papers, etc. (any text information that can be computer stored). Database tomography features a full text, user interactive technique enabling the user to identify areas of interest, establish relationships, and map trends for a deeper understanding of an area of interest. Database tomography concepts and applications have been reported in journals and presented at conferences. One important feature of the database tomography algorithm is that it can be used on a database of any size, and will facilitate the users ability to understand the volume of content therein. While employing the process to identify research opportunities it became obvious that this promising technology has potential applications for business, science, engineering, law, and academe. Examples include evaluating marketing trends, strategies, relationships and associations. Also, the database tomography process would be a powerful component in the area of competitive intelligence, national security intelligence and patent analysis. User interests and involvement cannot be overemphasized.

  12. Double-Difference Adjoint Tomography

    Science.gov (United States)

    Yuan, Yanhua O.; Simons, Frederik J.; Tromp, Jeroen

    2016-04-01

    We introduce a double-difference method for the inversion of seismic wavespeed structure by adjoint tomography. Differences between seismic observations and model-based predictions at individual stations may arise from factors other than structural heterogeneity, such as errors in the assumed source-time function, inaccurate timings, and systematic uncertainties. To alleviate the corresponding nonuniqueness in the inverse problem, we construct differential measurements between stations, thereby largely canceling out the source signature and systematic errors. We minimize the discrepancy between observations and simulations in terms of differential measurements made on station pairs. We show how to implement the double-difference concept in adjoint tomography, both theoretically and in practice. We compare the sensitivities of absolute and differential measurements. The former provide absolute information on structure along the ray paths between stations and sources, whereas the latter explain relative (and thus higher-resolution) structural variations in areas close to the stations. Whereas in conventional tomography, a measurement made on a single earthquake-station pair provides very limited structural information, in double-difference tomography, one earthquake can actually resolve significant details of the structure. The double-difference methodology can be incorporated into the usual adjoint tomography workflow by simply pairing up all conventional measurements; the computational cost of the necessary adjoint simulations is largely unaffected. Rather than adding to the computational burden, the inversion of double-difference measurements merely modifies the construction of the adjoint sources for data assimilation.

  13. Uni-axial compaction of a granular material

    Science.gov (United States)

    Morland, L. W.; Sawicki, A.; Milne, P. C.

    1993-11-01

    S HEARING OF GRANULAR materials causes rearrangement of the granular structure which induces irreversible volume decrease and shear strain, in addition to reversible strain. The model adopted describes the reversible compression and shear by hypoelastic laws, and the irreversible compaction and shear by evolutionary laws. The latter are differential relations defining the progress of irreversible strain as an appropriate time-independent monotonie loading parameter increases, which incorporate dependence on the current state, and which prescribe a direction for the irreversible shear strain increment. The model is described by four material functions and two material constants, and has been shown to determine valid initial response to applied shear stress. We apply the model to the compaction of a granular material in uni-axial strain, which is described by two simultaneous differential equations for the axial stress and compaction with the axial strain as independent variable, together with algebraic relations for the pressure and lateral stress. The equation forms for loading-increasing axial stress—and unloading—decreasing axial stress-are distinct. Reformulation as differential equations for the pressure and the principal stress difference shows that the pressure derivative depends only on two of the material functions and one constant. The axial strain and lateral stress measured during a complete load-unload cycle on a sand determine the pressure and stress difference derivatives which are correlated directly with the model differential relations. Two material functions and one constant are determined by an optimization procedure from the complete loadunload ressure data, then the remaining two functions and constant from the stress difference data. Solution of the resulting model differential equations reproduces accurately the axial strain and lateral stress variations during the experimental loading cycle. In addition, model predictions for load

  14. Rapid, accurate, and non-invasive measurement of zebrafish axial length and other eye dimensions using SD-OCT allows longitudinal analysis of myopia and emmetropization.

    Directory of Open Access Journals (Sweden)

    Ross F Collery

    Full Text Available Refractive errors in vision can be caused by aberrant axial length of the eye, irregular corneal shape, or lens abnormalities. Causes of eye length overgrowth include multiple genetic loci, and visual parameters. We evaluate zebrafish as a potential animal model for studies of the genetic, cellular, and signaling basis of emmetropization and myopia. Axial length and other eye dimensions of zebrafish were measured using spectral domain-optical coherence tomography (SD-OCT. We used ocular lens and body metrics to normalize and compare eye size and relative refractive error (difference between observed retinal radial length and controls in wild-type and lrp2 zebrafish. Zebrafish were dark-reared to assess effects of visual deprivation on eye size. Two relative measurements, ocular axial length to body length and axial length to lens diameter, were found to accurately normalize comparisons of eye sizes between different sized fish (R2=0.9548, R2=0.9921. Ray-traced focal lengths of wild-type zebrafish lenses were equal to their retinal radii, while lrp2 eyes had longer retinal radii than focal lengths. Both genetic mutation (lrp2 and environmental manipulation (dark-rearing caused elongated eye axes. lrp2 mutants had relative refractive errors of -0.327 compared to wild-types, and dark-reared wild-type fish had relative refractive errors of -0.132 compared to light-reared siblings. Therefore, zebrafish eye anatomy (axial length, lens radius, retinal radius can be rapidly and accurately measured by SD-OCT, facilitating longitudinal studies of regulated eye growth and emmetropization. Specifically, genes homologous to human myopia candidates may be modified, inactivated or overexpressed in zebrafish, and myopia-sensitizing conditions used to probe gene-environment interactions. Our studies provide foundation for such investigations into genetic contributions that control eye size and impact refractive errors.

  15. Anterior Segment Tomography with the Cirrus Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Eduardo B. Rodrigues

    2012-01-01

    Full Text Available Optical coherence tomography (OCT is an optical acquisition method to examine biological tissues. In recent years, OCT has become an important imaging technology used in diagnosing and following macular pathologies. Further development enabled application of optical coherence tomography in evaluation of the integrity of the nerve fiber layer, optic nerve cupping, anterior chamber angle, or corneal topography. In this manuscript we overview the use of OCT in the clinical practice to enable corneal, iris, ciliary body, and angle evaluation and diagnostics.

  16. Physiologic positron emission tomography/CT imaging of an integrated orbital implant.

    Science.gov (United States)

    Graue, Gerardo F; Finger, Paul T

    2012-01-01

    A 46-year-old woman with a T4N0M0 choroidal melanoma was staged for metastatic disease with whole-body positron emission tomography/CT imaging. She underwent enucleation of the right eye and placement of a 20-mm MEDPOR spherical implant. Four months after surgery, follow-up positron emission tomography/CT imaging revealed physiologic metabolic activity in the MEDPOR implant with no evidence of orbital melanoma or chronic inflammation.

  17. Axially extended-volume C-arm CT using a reverse helical trajectory in the interventional room.

    Science.gov (United States)

    Yu, Zhicong; Maier, Andreas; Lauritsch, Gunter; Vogt, Florian; Schonborn, Manfred; Kohler, Christoph; Hornegger, Joachim; Noo, Frederic

    2015-01-01

    C-arm computed tomography (CT) is an innovative technique that enables a C-arm system to generate 3-D images from a set of 2-D X-ray projections. This technique can reduce treatment-related complications and may improve interventional efficacy and safety. However, state-of-the-art C-arm systems rely on a circular short scan for data acquisition, which limits coverage in the axial direction. This limitation was reported as a problem in hepatic vascular interventions. To solve this problem, as well as to further extend the value of C-arm CT, axially extended-volume C-arm CT is needed. For example, such an extension would enable imaging the full aorta, the peripheral arteries or the spine in the interventional room, which is currently not feasible. In this paper, we demonstrate that performing long object imaging using a reverse helix is feasible in the interventional room. This demonstration involved developing a novel calibration method, assessing geometric repeatability, implementing a reconstruction method that applies to real reverse helical data, and quantitatively evaluating image quality. Our results show that: 1) the reverse helical trajectory can be implemented and reliably repeated on a multiaxis C-arm system; and 2) a long volume can be reconstructed with satisfactory image quality using reverse helical data.

  18. Geometry of the articular facets of the lateral atlanto-axial joints in the case of occipitalization.

    Science.gov (United States)

    Ryniewicz, A M; Skrzat, J; Ryniewicz, A; Ryniewicz, W; Walocha, J

    2010-08-01

    This study investigates if atlanto-occipital fusion affects the size and geometrical configuration of the articular facets of the atlanto-axial joint. Morphometric analysis was performed on the male adult skull, the occipital bone of which is assimilated with the first cervical vertebrae (the atlas). The perimeter, Feret's diameter, surface area, and circularity of the inferior articular fa-cets were measured. However, we did not observe significant bilateral differences in size of the inferior articular facets of the assimilated atlas compared to normal first cervical vertebrae. Geometrical conformation of the articular facets of the atlas and axis was assessed using a coordinate measuring machine (PMM - 12106, Leitz). The results obtained from this machine indicated that the inferior articular facets of the assimilated atlas presented asymmetrical orientation compared to the normal anatomy of the atlas. Hence, in the case of occipitalization, the gap between the articulating facets of the atlas and the axis was measured to be greater than in the normal atlanto-axial joint. Computer assisted tomography was applied to visualise the anatomical relationship between the inferior articular facets of the assimilated atlas and the corresponding facets located on the axis. In this case, radiographic examination revealed that the bilaterally articulating facets (inferior and superior) showed disproportion in their adjustment within the lateral atlanto-axial joints. Thus, we concluded that the fusion of the atlas with the occipital bone altered the geometry of the inferior articular facets of the atlas and influenced the orientation of the superior articular facets of the axis.

  19. Unilateral atlanto-axial fractures in near side impact collisions: An under recognized entity in cervical trauma

    Directory of Open Access Journals (Sweden)

    Andrew M Lozen

    2014-01-01

    Full Text Available Objective: Nearside impact collisions presenting with lateral mass fractures of atlanto-axial vertebrae contralateral to the impact site represents a rare fracture pattern that does not correlate with previously described injury mechanism. We describe our clinical experience with such fractures and propose a novel description of biomechanical forces involved in this unique injury pattern. The findings serve to alert clinicians to potentially serious consequences of associated unrecognized and untreated vertebral artery injury. Material and Methods : In addition to describing our clinical experience with three of these fractures, a review of Crash Injury Research and Engineering Network (CIREN database was conducted to further characterize such fractures. A descriptive analysis of three recent lateral mass fractures of the atlanto-axial segment is coupled with a review of the CIREN database. A total of 4047 collisions were screened for unilateral fractures of atlas or axis. Information was screened for side of impact and data regarding impact velocity, occupant injuries and use of restraints. Results: Following screening of unilateral fractures of atlas and axis for direct side impacts, 41 fractures were identified. Cross referencing these cases for occurrence contralateral to side of impact identified four such fractures. Including our recent clinical experience, seven injuries were identified: Five C1 and two C2 fractures. Velocity ranged from 14 to 43 km/h. Two associated vertebral artery injuries were identified. Conclusions: Complexity of the atlanto-axial complex is responsible for a sequence of events that define load application in side impacts. This study demonstrates the vulnerability of vertebral artery to injury under unique translational forces and supports the use or routine screening for vascular injury. Diminished sensitivity of plain radiography in identifying these injuries suggests that computerized tomography should be used in

  20. Are we ready for positron emission tomography/computed tomography-based target volume definition in lymphoma radiation therapy?

    Science.gov (United States)

    Yeoh, Kheng-Wei; Mikhaeel, N George

    2013-01-01

    Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) has become indispensable for the clinical management of lymphomas. With consistent evidence that it is more accurate than anatomic imaging in the staging and response assessment of many lymphoma subtypes, its utility continues to increase. There have therefore been efforts to incorporate PET/CT data into radiation therapy decision making and in the planning process. Further, there have also been studies investigating target volume definition for radiation therapy using PET/CT data. This article will critically review the literature and ongoing studies on the above topics, examining the value and methods of adding PET/CT data to the radiation therapy treatment algorithm. We will also discuss the various challenges and the areas where more evidence is required.

  1. Quantum optical coherence tomography using three time-energy entangled photons

    Science.gov (United States)

    Lopez-Mago, Dorilian; Burguete, Arturo; Campos, Eernesto

    2016-09-01

    Quantum Optical Coherence Tomography can achieve a greater image resolution compared to its classical counterpart, due to the entanglement of the photon pairs. Following the idea that higher the number of entangled photons, higher the resolution, we study the physical underpinnings that appear when using photon triplets. Unlike the usual Hong-Ou-Mandel interferometer used for QOCT, a much simpler implementation in the form of a Michelson interferometer is used in this work. We find that axial resolution can be improved by a factor of four. Additionally, we provide the numerical method to reconstruct the image given the triple coincidence rate.

  2. High resolution computed tomography for malformations of the cochlear and vestibular organs

    Energy Technology Data Exchange (ETDEWEB)

    Koester, O.; Straehler-Pohl, H.J.; Kim, K.H.

    1987-07-01

    Twenty-one patients with congenital deformities of the petrous bones were examined by high resolution computed tomography. This allows an accurate description of the extent of the malformation in all parts of the cochlear and vestibular organs; only localised changes in the auditory ossicles, such as fixation of the stapes and changes in the soft tissue portions of the labyrinth, cannot be shown. Improved demonstration of soft tissues while using less radiation makes high resolution CT preferable to conventional polytomography. It is also easier to perform and provides axial projections which are essential for the elucidation of malformations of the middle and inner ear.

  3. Interpretation of computed tomography imaging of the eye and orbit. A systematic approach

    Directory of Open Access Journals (Sweden)

    Naik Milind

    2002-01-01

    Full Text Available Computed tomography (CT has revolutionised the diagnosis and management of ocular and orbital diseases. The use of thin sections with multiplanar scanning (axial, coronal and sagittal planes and the possibility of three-dimensional reconstruction permits thorough evaluation. To make the most of this technique, users must familiarize themselves with the pertinent CT principles and terminology. The diagnostic yield is optimal when the ophthalmologist and radiologist collaborate in the radiodiagnostic workup. In this article we describe a systematic approach to the interpretation of ocular and orbital CT scans.

  4. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  5. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  6. Test target for characterizing 3D resolution of optical coherence tomography

    Science.gov (United States)

    Hu, Zhixiong; Hao, Bingtao; Liu, Wenli; Hong, Baoyu; Li, Jiao

    2014-12-01

    Optical coherence tomography (OCT) is a non-invasive 3D imaging technology which has been applied or investigated in many diagnostic fields including ophthalmology, dermatology, dentistry, cardiovasology, endoscopy, brain imaging and so on. Optical resolution is an important characteristic that can describe the quality and utility of an image acquiring system. We employ 3D printing technology to design and fabricate a test target for characterizing 3D resolution of optical coherence tomography. The test target which mimics USAF 1951 test chart was produced with photopolymer. By measuring the 3D test target, axial resolution as well as lateral resolution of a spectral domain OCT system was evaluated. For comparison, conventional microscope and surface profiler were employed to characterize the 3D test targets. The results demonstrate that the 3D resolution test targets have the potential of qualitatively and quantitatively validating the performance of OCT systems.

  7. In vitro birefringence imaging with spectral domain polarization-sensitive optical coherence tomography

    Institute of Scientific and Technical Information of China (English)

    Qiang Gong; Chuanmao Fan; Fan Zhang; Jianquan Yao

    2008-01-01

    Spectral domain polarization-sensitive optical coherence tomography (SDPS-OCT) is a depth-resolved polarization-sensitive interferometry which integrates polarization optics into spectral domain optical co-herence tomography (SD-OCT). This configuration can obtain birefringence information of samples and improve the imaging speed. In this paper, horizontally polarized light is used to replace natural light of the source. Then, right-rotated circularly polarized light is the incident sample light. To obtain two orthogonal components of the polarized interferogram, the reflected light of the reference arm is set to be 45° linearly polarized light. These two components are acquired by two spectrometers synchronously. The system was employed to achieve 12.8-#m axial resolution and 4.36-#m transverse resolution. We have imaged in vitro chicken tendon and muscle tissues with these system.

  8. Swept source optical coherence tomography based on non-uniform discrete fourier transform

    Institute of Scientific and Technical Information of China (English)

    Tong Wu; Zhihua Ding; Kai Wang; Chuan Wang

    2009-01-01

    A high-speed high-sensitivity swept source optical coherence tomography (SSOCT) system using a high speed swept laser source is developed.Non-uniform discrete fourier transform (NDFT) method is introduced in the SSOCT system for data processing.Frequency calibration method based on a Mach-Zender interferometer (MZI) and conventional data interpolation method is also adopted in the system for comparison.Optical coherence tomography (OCT) images from SSOCT based on the NDFT method,the MZI method,and the interpolation method are illustrated.The axial resolution of the SSOCT based on the NDFT method is comparable to that of the SSOCT system using MZI calibration method and conventional data interpolation method.The SSOCT system based on the NDFT method can achieve higher signal intensity than that of the system based on the MZI calibration method and conventional data interpolation method because of the better utilization of the power of source.

  9. High-resolution second-harmonic optical coherence tomography of collagen in rat-tail tendon

    Science.gov (United States)

    Jiang, Yi; Tomov, Ivan V.; Wang, Yimin; Chen, Zhongping

    2005-03-01

    A high-resolution second-harmonic optical coherence tomography (SH-OCT) system is demonstrated using a spectrum broadened femtosecond Ti :sapphire laser. An axial resolution of 4.2μm at the second-harmonic wave center wavelength of 400 nm has been achieved. Because the SH-OCT system uses the second-harmonic generation signals that strongly depend on the orientation, polarization, and local symmetry properties of chiral molecules, this technique provides unique contrast enhancement to conventional optical coherence tomography. The system is applied to image biological tissues of the rat-tail tendon. Highly organized collagen fibrils in the rat-tail tendon can be visualized in recorded images.

  10. On the performance of circular concrete-filled high strength steel columns under axial loading

    Directory of Open Access Journals (Sweden)

    Mohamed Mahmoud El-Heweity

    2012-06-01

    Full Text Available This work presents a numerical study to investigate the performance of circular high-strength steel tubes filled with concrete (CFT under monotonic axial loading. A model is developed to implement the material constitutive relationships and non-linearity. Calibration against previous experimental data shows good agreement. A parametric study is then conducted using the model and compared with codes provisions. Strength and ductility of confined concrete are of primary concern. Variables considered are yield stress of steel tube and column diameter. The assessment of column performance is based on axial load carrying capacities and enhancements of both strength and ductility due to confinement. Two parameters namely strength enhancement factor (Kf and ductility index (μ are clearly defined and introduced for assessment. Results indicate that both concrete strength and ductility of CFT columns are enhanced but to different extents. The ductile behaviors are significantly evident. The increase in yield stress of steel tube has a minimal effect on concrete strength but pronounced effect on concrete ductility. However, reduction in ductility is associated with using high-tensile steel of Grade 70. The overall findings indicate that the use of high-strength tube in CFT columns is not promising. This finding may seriously be considered in seismic design.

  11. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus;

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  12. Electron tomography of dislocation structures

    Energy Technology Data Exchange (ETDEWEB)

    Liu, G.S.; House, S.D.; Kacher, J. [Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, 1304 W. Green St., Urbana, IL 61801 (United States); Tanaka, M.; Higashida, K. [Department of Materials Science and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Robertson, I.M., E-mail: irobertson@wisc.edu [Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, 1304 W. Green St., Urbana, IL 61801 (United States); Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, WI 53706 (United States)

    2014-01-15

    Recent developments in the application of electron tomography for characterizing microstructures in crystalline solids are described. The underlying principles for electron tomography are presented in the context of typical challenges in adapting the technique to crystalline systems and in using diffraction contrast imaging conditions. Methods for overcoming the limitations associated with the angular range, the number of acquired images, and uniformity of image contrast are introduced. In addition, a method for incorporating the real space coordinate system into the tomogram is presented. As the approach emphasizes development of experimental solutions to the challenges, the solutions developed and implemented are presented in the form of examples.

  13. Assessment of Safety and Interference Issues of Radio Frequency Identification Devices in 0.3 Tesla Magnetic Resonance Imaging and Computed Tomography

    Directory of Open Access Journals (Sweden)

    M. Periyasamy

    2014-01-01

    Full Text Available The objective of this study was to evaluate two issues regarding magnetic resonance imaging (MRI including device functionality and image artifacts for the presence of radio frequency identification devices (RFID in association with 0.3 Tesla at 12.7 MHz MRI and computed tomography (CT scanning. Fifteen samples of RFID tags with two different sizes (wristband and ID card types were tested. The tags were exposed to several MR-imaging conditions during MRI examination and X-rays of CT scan. Throughout the test, the tags were oriented in three different directions (axial, coronal, and sagittal relative to MRI system in order to cover all possible situations with respect to the patient undergoing MRI and CT scanning, wearing a RFID tag on wrist. We observed that the tags did not sustain physical damage with their functionality remaining unaffected even after MRI and CT scanning, and there was no alternation in previously stored data as well. In addition, no evidence of either signal loss or artifact was seen in the acquired MR and CT images. Therefore, we can conclude that the use of this passive RFID tag is safe for a patient undergoing MRI at 0.3 T/12.7 MHz and CT Scanning.

  14. Assessment of safety and interference issues of radio frequency identification devices in 0.3 Tesla magnetic resonance imaging and computed tomography.

    Science.gov (United States)

    Periyasamy, M; Dhanasekaran, R

    2014-01-01

    The objective of this study was to evaluate two issues regarding magnetic resonance imaging (MRI) including device functionality and image artifacts for the presence of radio frequency identification devices (RFID) in association with 0.3 Tesla at 12.7 MHz MRI and computed tomography (CT) scanning. Fifteen samples of RFID tags with two different sizes (wristband and ID card types) were tested. The tags were exposed to several MR-imaging conditions during MRI examination and X-rays of CT scan. Throughout the test, the tags were oriented in three different directions (axial, coronal, and sagittal) relative to MRI system in order to cover all possible situations with respect to the patient undergoing MRI and CT scanning, wearing a RFID tag on wrist. We observed that the tags did not sustain physical damage with their functionality remaining unaffected even after MRI and CT scanning, and there was no alternation in previously stored data as well. In addition, no evidence of either signal loss or artifact was seen in the acquired MR and CT images. Therefore, we can conclude that the use of this passive RFID tag is safe for a patient undergoing MRI at 0.3 T/12.7 MHz and CT Scanning.

  15. Early brain enlargement and elevated extra-axial fluid in infants who develop autism spectrum disorder.

    Science.gov (United States)

    Shen, Mark D; Nordahl, Christine W; Young, Gregory S; Wootton-Gorges, Sandra L; Lee, Aaron; Liston, Sarah E; Harrington, Kayla R; Ozonoff, Sally; Amaral, David G

    2013-09-01

    resonance imaging study to prospectively evaluate brain growth trajectories from infancy in children who develop autism spectrum disorder. The presence of excessive extra-axial fluid detected as early as 6 months and the lack of resolution by 24 months is a hitherto unreported brain anomaly in infants who later develop autism spectrum disorder. This is also the first magnetic resonance imaging evidence of brain enlargement in autism before age 2. These findings raise the potential for the use of structural magnetic resonance imaging to aid in the early detection of children at risk for autism spectrum disorder or other neurodevelopmental disorders.

  16. Tumor-Induced Osteomalacia Caused by Primary Fibroblast Growth Factor 23 Secreting Neoplasm in Axial Skeleton: A Case Report

    Directory of Open Access Journals (Sweden)

    Gunjan Y. Gandhi

    2012-01-01

    Full Text Available We report the case of a 66-year-old woman with tumor-induced osteomalacia (TIO caused by fibroblast growth factor 23 (FGF-23 secreting mesenchymal tumor localized in a lumbar vertebra and review other cases localized to the axial skeleton. She presented with nontraumatic low back pain and spontaneous bilateral femur fractures. Laboratory testing was remarkable for low serum phosphorus, phosphaturia, and significantly elevated serum FGF-23 level. Magnetic resonance imaging (MRI of the lumbar spine showed a focal lesion in the L-4 vertebra which was hypermetabolic on positron emission tomography (PET scan. A computed tomography (CT guided needle biopsy showed a low grade spindle cell neoplasm with positive FGF-23 mRNA expression by reverse transcriptase polymerase chain reaction (RT-PCR, confirming the diagnosis of a phosphaturic mesenchymal tumor mixed connective tissue variant (PMTMCT. The patient elected to have surgery involving anterior resection of L-4 vertebra with subsequent normalization of serum phosphorus. Including the present case, we identified 12 cases of neoplasms localized to spine causing TIO. To our knowledge, this paper represents the first documented case of lumbar vertebra PMT causing TIO. TIO is a rare metabolic bone disorder that carries a favorable prognosis. When a lesion is identifiable, surgical intervention is typically curative.

  17. Modelling larval transport in a axial convergence front

    Science.gov (United States)

    Robins, P.

    2010-12-01

    Marine larvae exhibit different vertical swimming behaviours, synchronised by factors such as tidal currents and daylight, in order to aid retention near the parent populations and hence promote production, avoid predation, or to stimulate digestion. This paper explores two types of larval migration in an estuarine axial convergent front which is an important circulatory mechanism in many coastal regions where larvae are concentrated. A parallelised, three-dimensional, ocean model was applied to an idealised estuarine channel which was parameterised from observations of an axial convergent front which occurs in the Conwy Estuary, U.K. (Nunes and Simpson, 1985). The model successfully simulates the bilateral cross-sectional recirculation of an axial convergent front, which has been attributed to lateral density gradients established by the interaction of the lateral shear of the longitudinal currents with the axial salinity gradients. On the flood tide, there is surface axial convergence whereas on the ebb tide, there is (weaker) surface divergence. Further simulations with increased/decreased tidal velocities and with stronger/weaker axial salinity gradients are planned so that the effects of a changing climate on the secondary flow can be understood. Three-dimensional Lagrangian Particle Tracking Models (PTMs) have been developed which use the simulated velocity fields to track larvae in the estuarine channel. The PTMs take into account the vertical migrations of two shellfish species that are commonly found in the Conwy Estuary: (i) tidal migration of the common shore crab (Carcinus maenas) and (ii), diel (daily) migration of the Great scallop (Pecten maximus). These migration behaviours are perhaps the most widespread amongst shellfish larvae and have been compared with passive (drifting) particles in order to assess their relative importance in terms of larval transport. Preliminary results suggest that the net along-estuary dispersal over a typical larval

  18. Ultrahigh-resolution optical coherence tomography and its application in insp ection of industrial materials%超高分辨光学相干层析成像技术与材料检测应用∗

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    Since many industrial materials have micro or submicro structures on the surface or subsurface, utrahigh-resolution is required in the inspection of these materials. Ultrahigh-resolution optical coherence tomography uses broadband light sources to achieve axial image resolutions on the scale of a few microns. We have been investigating an ultrahigh-resolution spectral-domain optical coherence tomography (SD-OCT) system using supercontinuum sources (SC) in free space. The effective SC spectrum has a full width at half maximum of 230 nm centered around 665 nm, and the imaging setup has an ultrahigh axial resolution of 0.9 µm in air, and a lateral resolution of 3.9 µm, with the system measurement range being 0.6 mm in axial direction. At a 50 µm axial position, the sensitivity can be 63 dB with 28600 axial scans per second at 2048 pixels per axial scan. Images of polystyrene microspheres solution with an average diameter of 5 µm and different sizes of industrial abrasive papers are presented to illustrate the performance of the system.

  19. The anomalous transport of axial charge: topological vs non-topological fluctuations

    CERN Document Server

    Iatrakis, Ioannis; Yin, Yi

    2015-01-01

    Axial charge imbalance is an essential ingredient in novel effects associated with chiral anomaly such as chiral magnetic effects (CME). In a non-Abelian plasma with chiral fermions, local axial charge can be generated a) by topological fluctuations which would create domains with non-zero winding number b) by conventional non-topological thermal fluctuations. We provide a holographic evaluations of medium's response to dynamically generated axial charge density in hydrodynamic limit and examine if medium's response depends on the microscopic origins of axial charge imbalance. We show a local domain with non-zero winding number would induce a non-dissipative axial current due to chiral anomaly. We illustrate holographically that a local axial charge imbalance would be damped out with the damping rate related to Chern-Simon diffusive constant. By computing chiral magnetic current in the presence of dynamically generated axial charge density, we found that the ratio of CME current over the axial charge density ...

  20. Investigation on a procedure for optimal axial depth of cut accuracy in micromilling

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    On the basis of a previously developed procedure for control of axial depth of cut in high accuracy micromilling operations, this paper presents an investigation on the estimation of the uncertainty of the set axial depth of cut....

  1. Computed tomography:the details.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2007-07-01

    Computed Tomography (CT) is a well established technique, particularly in medical imaging, but also applied in Synthetic Aperture Radar (SAR) imaging. Basic CT imaging via back-projection is treated in many texts, but often with insufficient detail to appreciate subtleties such as the role of non-uniform sampling densities. Herein are given some details often neglected in many texts.

  2. Optical tomography with structured illumination.

    Science.gov (United States)

    Lukic, Vladimir; Markel, Vadim A; Schotland, John C

    2009-04-01

    We consider the image reconstruction problem for optical tomography with structured illumination. A fast image reconstruction algorithm is proposed that reduces the required number of measurements of the optical field compared to methods that utilize point-source illumination. The results are illustrated with numerical simulations.

  3. Buckling localization in a cylindrical panel under axial compression

    DEFF Research Database (Denmark)

    Tvergaard, Viggo; Needleman, A.

    2000-01-01

    Localization of an initially periodic buckling pattern is investigated for an axially compressed elastic-plastic cylindrical panel of the type occurring between axial stiffeners on cylindrical shells. The phenomenon of buckling localization and its analogy with plastic flow localization in tensile...... test specimens is discussed in general. For the cylindrical panel, it is shown that buckling localization develops shortly after a maximum load has been attained, and this occurs for a purely elastic panel as well as for elastic-plastic panels. In a case where localization occurs after a load maximum......, but where subsequently the load starts to increase again, it is found that near the local load minimum, the buckling pattern switches back to a periodic type of pattern. The inelastic material behavior of the panel is described in terms of J(2) corner theory, which avoids the sometimes unrealistically high...

  4. Effect of axial mixing on RDC and PSE columns performance

    CERN Document Server

    Bastani, D

    2001-01-01

    Using the experimental data obtained from two RDC columns at two different sizes (7.62 and 21.9 cm) and one PSE column with 21.5 cm size, the effect of axial mixing on the performance of these columns was studied. Comparison between the experimental and theoretical (neglecting the axial mixing) number of transfer units indicates that, this effect in PSE columns is more than RDC columns (400% and 200% respectively). These results show that this effect can increase the height of the PSE column up to 4 times for a specific efficiency. Also the results show that this effect is more in law interfacial tension systems, which shows no need of application of agitation facilities when these systems are used.

  5. A velocity parameter for the correlation of axial fan noise

    Science.gov (United States)

    Wright, T.

    1982-08-01

    An aerodynamic parameter that relates subsonic axial fan noise to the fundamental flow behavior in the blade row of a fan is proposed. The parameter is the peak or maximum blade surface velocity in the rotating reference frame and includes, either explicitly or implicitly, the influence of tip speed, volume flow rate, pressure rise, shaft horsepower and efficiency. Correlation of the noise associated with a very broad range of axial fans yields good agreement and collapse of data when compared to currently used correlation methods. Use of this parameter, rather than those based on overall performance, allows trade-off studies to be made within a given performance requirement so that a minimum noise configuration may be designed or selected.

  6. Reduced aniseikonia in axial anisometropia with contact lens correction.

    Science.gov (United States)

    Winn, B; Ackerley, R G; Brown, C A; Murray, F K; Prais, J; St John, M F

    1988-01-01

    Aniseikonia, although present in isometropia, is associated principally with anisometropia and is widely thought to be the result of differences in the retinal image size presented to each eye. This assumes that equating retinal image size results in congruous cortical images. To test this assumption 1 refractive and 17 axial anisometropic subjects were examined to determine the aniseikonia present when corrected with spectacles and contact lenses. Contrary to many previous predictions, based upon Knapp's Law, the presence of equal retinal images resulted in larger aniseikonias than observed when the eyes were presented with unequal retinal images. This suggests that non-optical components have a significant role in the production of the cortical image, and this therefore requires a shift in the way the management of anisometropia is considered clinically. Contact lens correction maintains the aniseikonia at a minimum level in axial as well as refractive anisometropia and offers the clinician an acceptable practical alternative when prescribing for these patients.

  7. Ritual relieved axial dystonia triggered by gaze-evoked amaurosis.

    Science.gov (United States)

    Jacome, D E

    1997-11-01

    A woman with chronic posttraumatic axial lateropulsion cervical dystonia ("belly dancer's head") found relief of her spontaneous dystonic spasms by the sequential performance of an elaborate motor ritual. During an episode of left optic papillitis caused by central retinal vein occlusion, gaze-evoked amaurosis of the left eye developed, preceded by achromatopsia, during left lateral gaze. Gaze-evoked amaurosis triggered axial dystonia, which was followed by her unique, stereotyped, dystonia-relieving ritual that simulated a slow dance. Visual symptoms improved progressively in 1 year. Eventually, she was unable to trigger her dystonia by eye movements. Spontaneous dystonia remained otherwise unchanged from before the episode of papillitis and was still relieved by her unique ritual.

  8. Plasticity around an Axial Surface Crack in a Cylindrical Shell

    DEFF Research Database (Denmark)

    Krenk, Steen

    1979-01-01

    and Ratwani,3–5 it generalises Dugdale's assumption of a concentrated yield zone in the plane of the crack but, contrary to that model, transverse shear effects are included and a continuous stress distribution is assumed in the yield zone. The inherent difficulties arising from the use of shell theory...... field in an axially cracked cylindrical shell arising from use of classical eighth order shallow shell theory is removed when use is made of a tenth order shell theory which accounts for transverse shear deformations. Although the membrane stresses are only moderately affected, the influence...... on the bending stresses is considerable. In the case of surface cracks moments are induced due to the eccentricity of the crack and transverse shear effects should therefore be included. A plasticity model for a rectangular axial surface crack is developed. Like a previous surface crack model by Erdogen...

  9. Instability of meridional axial system in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Sharif, M.; Yousaf, Z. [University of the Punjab, Department of Mathematics, Lahore (Pakistan)

    2015-05-15

    We analyze the dynamical instability of a non-static reflection axial stellar structure by taking into account the generalized Euler equation in metric f(R) gravity. Such an equation is obtained by contracting the Bianchi identities of the usual anisotropic and effective stress-energy tensors, which after using a radial perturbation technique gives a modified collapse equation. In the realm of the R + εR{sup n} gravity model, we investigate instability constraints at Newtonian and post-Newtonian approximations. We find that the instability of a meridional axial self-gravitating system depends upon the static profile of the structure coefficients, while f(R) extra curvature terms induce the stability of the evolving celestial body. (orig.)

  10. Right parietal stroke with Gerstmann's syndrome. Appearance on computed tomography, magnetic resonance imaging, and single-photon emission computed tomography.

    Science.gov (United States)

    Moore, M R; Saver, J L; Johnson, K A; Romero, J A

    1991-04-01

    We examined a patient who exhibited Gerstmann's syndrome (left-right disorientation, finger agnosia, dyscalculia, and dysgraphia) in association with a perioperative stroke in the right parietal lobe. This is the first description of the Gerstmann tetrad occurring in the setting of discrete right hemisphere pathologic findings. A well-localized vascular lesion was demonstrated by computed tomography, magnetic resonance imaging, and single-photon emission computed tomographic studies. The patient had clinical evidence of reversed functional cerebral dominance and radiologic evidence of reversed anatomic cerebral asymmetries.

  11. Report on the Dynamical Evolution of an Axially Symmetric Quasar Model

    Indian Academy of Sciences (India)

    N. J. Papadopoulos; N. D. Caranicolas

    2006-12-01

    The role of the angular momentum in the regular or chaotic character of motion in an axially symmetric quasar model is examined. It is found that, for a given value of the critical angular momentum , there are two values of the mass of the nucleus for which transition from regular to chaotic motion occurs. The [-] relationship shows a linear dependence for the time independent model and an exponential dependence for the evolving model. Both cases are explained using theoretical arguments together with some numerical evidence. The evolution of the orbits is studied, as mass is transported from the disk to the nucleus. The results are compared with the outcomes derived for galactic models with massive nuclei.

  12. AXIAL RATIO OF EDGE-ON SPIRAL GALAXIES AS A TEST FOR BRIGHT RADIO HALOS

    Energy Technology Data Exchange (ETDEWEB)

    Singal, J.; Jones, E.; Dunlap, H. [Physics Department, University of Richmond 28 Westhampton Way, Richmond, VA 23173 (United States); Kogut, A., E-mail: jsingal@richmond.edu [Code 665, NASA Goddard Space Flight Center Greenbelt, MD 20771 (United States)

    2015-01-20

    We use surface brightness contour maps of nearby edge-on spiral galaxies to determine whether extended bright radio halos are common. In particular, we test a recent model of the spatial structure of the diffuse radio continuum by Subrahmanyan and Cowsik which posits that a substantial fraction of the observed high-latitude surface brightness originates from an extended Galactic halo of uniform emissivity. Measurements of the axial ratio of emission contours within a sample of normal spiral galaxies at 1500 MHz and below show no evidence for such a bright, extended radio halo. Either the Galaxy is atypical compared to nearby quiescent spirals or the bulk of the observed high-latitude emission does not originate from this type of extended halo. (letters)

  13. Parametric Analysis of Composite Reinforced Wood Tubes Under Axial Compression

    OpenAIRE

    Cabrero, J.; Heiduschke, A.; Haller, P. (P.)

    2010-01-01

    Wood tubes combine economy, an efficient use of the material and optimal structural performance. They can be optionally reinforced with technical fibers and/or textiles laminated to the outer wood surface. The paper presents the outcomes of a parametric study on the performance of wood reinforced tubes submitted to axial compression. Simple analytical models were applied to estimate the load-carrying capacity of the tubes and their failure mechanisms. Analytical and numerical models were deve...

  14. A Nonlocal Model for Carbon Nanotubes under Axial Loads

    Directory of Open Access Journals (Sweden)

    Raffaele Barretta

    2013-01-01

    Full Text Available Various beam theories are formulated in literature using the nonlocal differential constitutive relation proposed by Eringen. A new variational framework is derived in the present paper by following a consistent thermodynamic approach based on a nonlocal constitutive law of gradient-type. Contrary to the results obtained by Eringen, the new model exhibits the nonlocality effect also for constant axial load distributions. The treatment can be adopted to get new benchmarks for numerical analyses.

  15. Dynamic Response of Axially Loaded Euler-Bernoulli Beams

    DEFF Research Database (Denmark)

    Bayat, M.; Barari, Amin; Shahidi, M.

    2011-01-01

    The current research deals with application of a new analytical technique called Energy Balance Method (EBM) for a nonlinear problem. Energy Balance Method is used to obtain the analytical solution for nonlinear vibration behavior of Euler-Bernoulli beams subjected to axial loads. Analytical expr...... to the conventional methods, only one iteration leads to high accuracy of the solutions which are valid for a wide range of vibration amplitudes....

  16. Overview of the Axial Field Spectrometer in the ISR tunnel

    CERN Multimedia

    1980-01-01

    A view of the Axial Field Spectrometer – the last large experiment at the ISR. The horizontal top and vertical outer arrays of the uranium-scintillator hadron calorimeter are clear to be seen, with the blue cylindrical pole piece of the magnet just visible. The pipes that are visible in front of the pole piece are cryogenic feed pipes for the superconducting low-beta quadrupoles.

  17. Dynamics and statics of flexible axially symmetric shallow shells

    OpenAIRE

    2006-01-01

    In this work, we propose the method for the investigation of stochastic vibrations of deterministic mechanical systems represented by axially symmetric spherical shells. These structure members are widely used as sensitive elements of pressure measuring devices in various branches of measuring and control industry, machine design, and so forth. The proposed method can be easily extended for the investigation of shallow spherical shells, goffer-type membranes, and so on. T...

  18. Experimental investigations on an axial grooved cryogenic heat pipe

    Directory of Open Access Journals (Sweden)

    Senthil Kumar Muniappan

    2012-01-01

    Full Text Available This paper deals with development and studies of a trapezoidal axial grooved nitrogen heat pipe. A special liquid nitrogen cryostat has been designed and developed for evaluating the performance of heat pipe where the condenser portion is connected to the cold sink externally. Experiments have been performed on the heat pipe as well as on an equivalent diameter copper rod at different heat loads. The steady state performance of the heat pipe is compared with that of copper rod.

  19. Aerodynamic optimisation of an industrial axial fan blade

    OpenAIRE

    2006-01-01

    Numerical optimisation methods have successfully been used for a variety of aerodynamic design problems over quite a few years. However the application of these methods to the aerodynamic blade shape optimisation of industrial axial fans has received much less attention in the literature probably given the fact that the majority of resources available to develop these automated design approaches is to be found in the aerospace field. This work presents the develo...

  20. Measurement of axial injection displacement with trim coil current unbalance

    Science.gov (United States)

    Covo, Michel Kireeff

    2014-08-01

    The Dee probe used for measuring internal radial beam intensity shows large losses inside the radius of 20 cm of the 88 in. cyclotron. The current of the top and bottom innermost trim coil 1 is unbalanced to study effects of the axial injection displacement. A beam profile monitor images the ion beam bunches, turn by turn. The experimental bunch center of mass position is compared with calculations of the magnetic mirror effect displacement and shows good agreement.

  1. MRI of the axial skeletal manifestations of ankylosing spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Levine, D.S.; Forbat, S.M.; Saifuddin, A. E-mail: asaifuddin@aol.com

    2004-05-01

    Magnetic resonance imaging (MRI) is a valuable tool in the imaging and assessment of patients with ankylosing spondylitis. MRI can demonstrate the acute and chronic changes of sacroiliitis, osteitis, discovertebral lesions, disc calcifications and ossification and arthopathic lesions, which characterize the disease, as well as the complications, which include fracture and the rare cauda equina syndrome. This article reviews the range of MRI findings commonly seen within the axial skeleton in patients with this condition.

  2. Axial form factor of the nucleon at large momentum transfers

    CERN Document Server

    Anikin, I V; Offen, N

    2016-01-01

    Motivated by the emerging possibilities to study threshold pion electroproduction at large momentum transfers at Jefferson Laboratory following the 12 GeV upgrade, we provide a short theory summary and an estimate of the nucleon axial form factor for large virtualities in the $Q^2 = 1-10~\\text{GeV}^2$ range using next-to-leading order light-cone sum rules.

  3. Turbulence and Complex Flow Phenomena in Axial Turbomachines

    Science.gov (United States)

    2007-11-02

    Adamczyk J. J., 1996, "Wake Mixing in Axial Flow Compressors," ASME Paper No. 96-GT-029 Adamczyk J.J., Mulac R.A., Celestina M.L., 1986, "A Model for...Closing the Inviscid Form of the Average-Passage Equation System," ASME Paper No. 86-GT-227 Adamczyk J.J.; Celestina M.L.; Beach T.A.; Barnett M., 1990

  4. Experimental studies of axial magnetic fields generated in ultrashort-pulse laser-plasma interaction

    Institute of Scientific and Technical Information of China (English)

    李玉同; 张杰; 陈黎明; 赵理曾; 夏江帆; 魏志义; 江文勉

    2000-01-01

    The quasistatic axial magnetic fields in plasmas produced by ultrashort laser pulses were measured by measuring the Faraday rotation angle of the backscattered emission. The spatial distribution of the axial magnetic field was obtained with a peak value as high as 170 Tesla. Theory suggests that the axial magnetic field is generated by dynamo effect in laser-plasma interaction.

  5. Axial and Centrifugal Compressor Mean Line Flow Analysis Method

    Science.gov (United States)

    Veres, Joseph P.

    2009-01-01

    This paper describes a method to estimate key aerodynamic parameters of single and multistage axial and centrifugal compressors. This mean-line compressor code COMDES provides the capability of sizing single and multistage compressors quickly during the conceptual design process. Based on the compressible fluid flow equations and the Euler equation, the code can estimate rotor inlet and exit blade angles when run in the design mode. The design point rotor efficiency and stator losses are inputs to the code, and are modeled at off design. When run in the off-design analysis mode, it can be used to generate performance maps based on simple models for losses due to rotor incidence and inlet guide vane reset angle. The code can provide an improved understanding of basic aerodynamic parameters such as diffusion factor, loading levels and incidence, when matching multistage compressor blade rows at design and at part-speed operation. Rotor loading levels and relative velocity ratio are correlated to the onset of compressor surge. NASA Stage 37 and the three-stage NASA 74-A axial compressors were analyzed and the results compared to test data. The code has been used to generate the performance map for the NASA 76-B three-stage axial compressor featuring variable geometry. The compressor stages were aerodynamically matched at off-design speeds by adjusting the variable inlet guide vane and variable stator geometry angles to control the rotor diffusion factor and incidence angles.

  6. HTS axial flux induction motor with analytic and FEA modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, S., E-mail: alexlee.zn@gmail.com; Fan, Y.; Fang, J.; Qin, W.; Lv, G.; Li, J.H.

    2013-11-15

    Highlights: •A high temperature superconductor axial flux induction motor and a novel maglev scheme are presented. •Analytic method and finite element method have been adopted to model the motor and to calculate the force. •Magnetic field distribution in HTS coil is calculated by analytic method. •An effective method to improve the critical current of HTS coil is presented. •AC losses of HTS coils in the HTS axial flux induction motor are estimated and tested. -- Abstract: This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested.

  7. Behavior of Unbonded Flexible Risers Subject to Axial Tension

    Institute of Scientific and Technical Information of China (English)

    任少飞; 唐文勇; 郭晋挺

    2014-01-01

    Owing to nonlinear contact problems with slip and friction, a lot of limiting assumptions are made when developing analytical models to simulate the behavior of an unbonded flexible riser. Meanwhile, in order to avoid convergence problems and excessive calculating time associated with running the detailed finite element (FE) model of an unbonded flexible riser, interlocked carcass and zeta layers with complicated cross section shapes are replaced by simple geometrical shapes (e.g. hollow cylindrical shell) with equivalent orthotropic materials. But the simplified model does not imply the stresses equivalence of these two layers. To solve these problems, based on ABAQUS/Explicit, a numerical method that is suitable for the detailed FE model is proposed. In consideration of interaction among all component layers, the axial stiffness of an eight-layer unbonded flexible riser subjected to axial tension is predicted. Compared with analytical and experimental results, it is shown that the proposed numerical method not only has high accuracy but also can substantially reduce the calculating time. In addition, the impact of the lay angle of helical tendons on axial stiffness is discussed.

  8. Numerical Analysis of Erosion Caused by Biomimetic Axial Fan Blade

    Directory of Open Access Journals (Sweden)

    Jun-Qiu Zhang

    2013-01-01

    Full Text Available Damage caused by erosion has been reported in several industries for a wide range of situations. In the present work, a new method is presented to improve the erosion resistance of machine components by biomimetic method. A numerical investigation of solid particle erosion in the standard and biomimetic configuration blade of axial fan is presented. The analysis consists in the application of the discrete phase model, for modeling the solid particles flow, and the Eulerian conservation equations to the continuous phase. The numerical study employs computational fluid dynamics (CFD software, based on a finite volume method. User-defined function was used to define wear equation. Gas/solid flow axial fan was simulated to calculate the erosion rate of the particles on the fan blades and comparatively analyzed the erosive wear of the smooth surface, the groove-shaped, and convex hull-shaped biomimetic surface axial flow fan blade. The results show that the groove-shaped biomimetic blade antierosion ability is better than that of the other two fan blades. Thoroughly analyze of antierosion mechanism of the biomimetic blade from many factors including the flow velocity contours and flow path lines, impact velocity, impact angle, particle trajectories, and the number of collisions.

  9. Magnetic and axial-vector transitions of the baryon antidecuplet

    CERN Document Server

    Kim, H -Ch; Göke, K

    2007-01-01

    We report the recent results of the magnetic transitions and axial-vector transitions of the baryon antidecuplet within the framework of the chiral quark-soliton model. The dynamical model parameters are fixed by experimental data for the magnetic moments of the baryon octet, for the hyperon semileptonic decay constants, and for the singlet axial-vector constant. The transition magnetic moments $\\mu_{\\Lambda\\Sigma}$ and $\\mu_{N\\Delta}$ are well reproduced and other octet-decuplet and octet-antidecuplet transitions are predicted. In particular, the present calculation of $\\mu_{\\Sigma\\Sigma^*}$ is found to be below the upper bound $0.82\\mu_N$ that the SELEX collaboration measured very recently. The results explains consistently the recent findings of a new $N^*$ resonance from the GRAAL and Tohoku LNS group. We also obtain the transition axial-vector constants for the $\\Theta^+\\to KN$ from which the decay width of the $\\Theta^{+}$ pentaquark baryon is determined as a function of the pion-nucleon sigma term $\\Si...

  10. On the axial $U(1)$ symmetry at finite temperature

    CERN Document Server

    Cossu, Guido; Hashimoto, Shoji; Noaki, Jun-ichi; Tomiya, Akio

    2015-01-01

    We study the $U(1)_A$ anomaly in two-flavor lattice QCD at finite temperature with the M\\"obius domain-wall Dirac operator. We generate gauge configurations in the temperature range $(0.9, 1.2) T_c$ on different physical volumes, $L=$ 2--4 fm, and lattice spacings. We measure the difference of the susceptibilities of the flavor non-singlet scalar ($\\chi_\\delta$) and pseudoscalar ($\\chi_\\pi$) mesons. They are related by an axial $U(1)$ transformation and the difference vanishes if the axial $U(1)$ symmetry is respected. We identify the source of axial $U(1)$ symmetry breaking at finite temperature in the lowest eigenmodes, for the observable $\\chi_\\pi - \\chi_\\delta$. We then reweight the M\\"obius domain-wall fermion partition function to that of the overlap-Dirac operator to fully recover chiral symmetry. Our data show a significant discrepancy in the results coming from the M\\"obius domain-wall valence quarks, the overlap valence quarks on our DWF configurations and the reweighted ones that have full chiral s...

  11. Axial stress localization facilitates pressure propagation in gelled pipes

    Science.gov (United States)

    Norrman, Jens; Skjæraasen, Olaf; Oschmann, Hans-Jörg; Paso, Kristofer; Sjöblom, Johan

    2016-03-01

    Paraffin wax-oil gels are unique rheological fluids which undergo shear degradation starting at a deformation (shear strain level) of approximately 1%. Flow commencement in pipelines filled with wax-oil gels is a complex hydrodynamic process involving propagation of acoustic, diffusive, and rheological degradation pressure wave fronts. Dynamic simulation informed by qualified rheological relations provides useful insight into the physical nature of these flow processes. Eulerian simulations are presented which emulate known physical phenomena and essential characteristics of wax-gel flow dynamics. A constitutive rheological equation set accounts for deformation-driven reduction in yield stress and viscosity terms. No explicit time-dependent rheological parameters are utilized in the equations. Rheological yielding alters the nature of the dominant pressure wave from inherently diffusive towards self-sharpening. Axial stress localization effectively sequentializes the gel breakage process, quantified by reduced length of the pressure wave-front zone. Ultimately, axial stress localization allows flow in longer pipe segments, albeit with a concomitant time delay. Viscous behavior and yielding degradation behavior are shown to account for upward and downward concavity in transient axial pressure profiles, respectively. Overall, a unique synergy between gel compressibility and gel degradation is revealed. Deformation-coupled interaction between compressibility and degradation allows pressure propagation and subsequent sustained flow through a gel material which is otherwise immobile in the incompressible case.

  12. Characteristics of tip-leakage flow in an axial fan

    Science.gov (United States)

    Park, Keuntae; Choi, Haecheon; Choi, Seokho; Sa, Yongcheol

    2014-11-01

    An axial fan with a shroud generates complicated vortical structures by the interaction of the axial flow with the fan blades and shroud near the blade tips. Large eddy simulation (LES) is performed for flow through a forward-swept axial fan, operating at the design condition of Re = 547,000 based on the radius of blade tip and the tip velocity. A dynamic global model (Lee et al. 2010) is used for a subgrid-scale model, and an immersed boundary method in a non-inertial reference frame (Kim & Choi 2006) is adopted for the present simulation. It is found that two vortical structures are formed near the blade tip: the main tip leakage vortex (TLV) and the auxiliary TLV. The main TLV is initiated near the leading edge, develops downstream, and impinges on the pressure surface of the next blade, where the pressure fluctuations and turbulence intensity become high. On the other hand, the auxiliary TLV is initiated at the aft part of the blade but is relatively weak such that it merges with the main TLV. Supported by the KISTI Supercomputing Center (KSC-2014-C2-014).

  13. Imaging results and TOF studies with axial PET detectors

    CERN Document Server

    Joram, Christian

    2013-01-01

    We have developed a fully operational PET demonstrator setup which allows true 3D reconstruction of the 511 keV photons and therefore leads to practically parallax free images. The AX-PET concept is based on thin 100 mm long scintillation crystals (LYSO), axially oriented and arranged in layers around the held of view. Layers of wavelength shifting plastic strips mounted in between the crystal layers give the axial coordinate. Both crystals and WLS strips are individually read out by G-APD (SiPM) photodetectors. The Fully scalable concept overcomes the dilemma of sensitivity versus spatial resolution which is inherent to classical PET designs. A demonstrator set-up based on two axial modules was exhaustively characterized using point-like sources, phantoms filled with radiotracer and finally rats and a mouse. The results entirely meet the performance expectations ( <2 mm FWHM in all three coordinates over the complete held of view) and also demonstrated the ability to include Compton interactions (inter-cr...

  14. The new performance calculation method of fouled axial flow compressor.

    Science.gov (United States)

    Yang, Huadong; Xu, Hong

    2014-01-01

    Fouling is the most important performance degradation factor, so it is necessary to accurately predict the effect of fouling on engine performance. In the previous research, it is very difficult to accurately model the fouled axial flow compressor. This paper develops a new performance calculation method of fouled multistage axial flow compressor based on experiment result and operating data. For multistage compressor, the whole compressor is decomposed into two sections. The first section includes the first 50% stages which reflect the fouling level, and the second section includes the last 50% stages which are viewed as the clean stage because of less deposits. In this model, the performance of the first section is obtained by combining scaling law method and linear progression model with traditional stage stacking method; simultaneously ambient conditions and engine configurations are considered. On the other hand, the performance of the second section is calculated by averaged infinitesimal stage method which is based on Reynolds' law of similarity. Finally, the model is successfully applied to predict the 8-stage axial flow compressor and 16-stage LM2500-30 compressor. The change of thermodynamic parameters such as pressure ratio, efficiency with the operating time, and stage number is analyzed in detail.

  15. The New Performance Calculation Method of Fouled Axial Flow Compressor

    Directory of Open Access Journals (Sweden)

    Huadong Yang

    2014-01-01

    Full Text Available Fouling is the most important performance degradation factor, so it is necessary to accurately predict the effect of fouling on engine performance. In the previous research, it is very difficult to accurately model the fouled axial flow compressor. This paper develops a new performance calculation method of fouled multistage axial flow compressor based on experiment result and operating data. For multistage compressor, the whole compressor is decomposed into two sections. The first section includes the first 50% stages which reflect the fouling level, and the second section includes the last 50% stages which are viewed as the clean stage because of less deposits. In this model, the performance of the first section is obtained by combining scaling law method and linear progression model with traditional stage stacking method; simultaneously ambient conditions and engine configurations are considered. On the other hand, the performance of the second section is calculated by averaged infinitesimal stage method which is based on Reynolds’ law of similarity. Finally, the model is successfully applied to predict the 8-stage axial flow compressor and 16-stage LM2500-30 compressor. The change of thermodynamic parameters such as pressure ratio, efficiency with the operating time, and stage number is analyzed in detail.

  16. Axial Non-linear Dynamic Soil-Pile Interaction - Keynote

    Directory of Open Access Journals (Sweden)

    Holeyman A.

    2014-01-01

    Full Text Available This keynote lecture describes recent analytical and numerical advances in the modeling of the axial nonlinear dynamic interaction between a single pile and its embedding soil. On one hand, analytical solutions are developed for assessing the nonlinear axial dynamic response of the shaft of a pile subjected to dynamic loads, and in particular to vibratory loads. Radial inhomogeneity arising from shear modulus degradation is evaluated over a range of parameters and compared with those obtained by other authors and by a numerical radial discrete model simulating the pile and soil movements from integration of the laws of motion. New approximate non linear solutions for axial pile shaft behaviour developed from general elastodynamic equations are presented and compared to existing linear solutions. The soil non linear behaviour and its ability to dissipate mechanical energy upon cyclic loading are shown to have a significant influence on the mechanical impedance provided by the surrounding soil against pile shaft movement. The limitations of over-simplified modelling of pile response are highlighted.

  17. EDITORIAL: Optical tomography and digital holography

    Science.gov (United States)

    Coupland, Jeremy; Lobera, Julia

    2008-07-01

    this for the case of mono-disperse particles in air. Here the number density of the particles is such that multiple scattering is prevalent; however, a priori knowledge of particle size and refractive index allows individual particles to be located accurately. In general, reconstruction can be thought of as a nonlinear optimization process that is used to discover the object which best explains the measured field and is consistent with a priori information. As Gire et al point out in their article, a priori knowledge can also be used to overcome the Nyquist sampling criteria. Although some caution should be exercised (for example, it is not usually possible to decide whether a given solution is unique), it is interesting to note that despite the disparity in resolution, digital holography and computer technology might yet create 3D images of greater clarity than the best optical holograms. References [1] Schnars U and Jueptner W 2005 Digital Holography (Berlin: Springer) ISBN: 978 3 540 21934 7 [2] Gabor D 1948 A new microscopic principle Nature 161 777-8 [3] Bjelkhagen H I 1993 Silver-Halide Recording Materials (Berlin: Springer) ISBN 3 540 58619 9 [4] Leendertz J A 1970 Interferometric displacement measurement on scattering surfaces utilizing speckle effect J. Phys. E: Sci. Instrum. 3 214-8 [5] Marquet P, Rappaz B, Magistretti P J, Cuche E, Emery Y, Colomb T and Depeursinge C 2005 Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy Opt. Lett. 30 468-70 [6] Wolf E 1969 Three-dimensional structure determination of semi-transparent objects from holographic data Opt. Commun. 1 153-6 [7] Dandliker R and Weiss K 1970 Reconstruction of the three-dimensional refractive index from scattered waves Opt. Commun. 1 323-8 [8] Coupland J and Lobera J 2007 International Workshop on Digital Holographic Reconstruction and Optical Tomography for Engineering Applications ISBN 978 0

  18. Peri-implant biomechanical responses to standard, short-wide, and mini implants supporting single crowns under axial and off-axial loading (an in vitro study).

    Science.gov (United States)

    Kheiralla, Lamia Sayed; Younis, Jihan Farouk

    2014-02-01

    This study compared the biomechanical responses of 3 single crowns supported by 3 different implants under axial and off-axial loading. A standard implant (3.75 mm diameter, 13 mm length), a mini implant (3 mm diameter, 13 mm length), and a short-wide implant (5.7 mm diameter, 8 mm length) were embedded in epoxy resin by the aid of a surveyor to ensure their parallelism. Each implant supported a full metal crown made of Ni-Cr alloy with standardized dimensions. Strain gauges and finite element analysis (FEA) were used to measure the strain induced under axial and off-axial functional loads of 300 N. Results showed that mini implants recorded the highest microstrains, under both axial and off-axial loading. All implants showed a considerable increase in strain values under off-axial loading. Standard and short-wide implants proved to be preferable in supporting crowns, as the standard implant showed the lowest strains under axial and off-axial loading using FEA simulation, while the short-wide implant showed the lowest strains under nonaxial loading using strain gauge analysis.

  19. Axial-transversal coupling in the free nonlinear vibrations of Timoshenko beams with arbitrary slenderness and axial boundary conditions

    Science.gov (United States)

    Lenci, Stefano; Rega, Giuseppe

    2016-06-01

    The nonlinear free oscillations of a straight planar Timoshenko beam are investigated analytically by means of the asymptotic development method. Attention is focused for the first time, to the best of our knowledge, on the nonlinear coupling between the axial and the transversal oscillations of the beam, which are decoupled in the linear regime. The existence of coupled and uncoupled motion is discussed. Furthermore, the softening versus hardening nature of the backbone curves is investigated in depth. The results are summarized by means of behaviour charts that illustrate the different possible classes of motion in the parameter space. New, and partially unexpected, phenomena, such as the changing of the nonlinear behaviour from softening to hardening by adding/removing the axial vibrations, are highlighted.

  20. Axial psoriatic arthritis: an intriguing clinical entity or a subset of an intriguing disease?

    Science.gov (United States)

    Lubrano, Ennio; Spadaro, Antonio

    2012-07-01

    This article summarizes the state of the art of axial involvement in psoriatic arthritis (axial PsA). The definition and measurement of axial disease in PsA still remain problematic, and this, in turn, could affect the best approach of recognition and treatment of this intriguing subset of the psoriatic disease. Axial PsA has been studied over the last few years looking at the difference in function and radiological finding compared to ankylosing spondylitis (AS), trying to differentiate it from a coincidental AS with psoriasis. Finally, this review has described the diagnosis and treatment of axial PsA reporting the data obtained from the literature.

  1. Application of the wavelet transforms on axial strain calculation in ultrasound elastography

    Institute of Scientific and Technical Information of China (English)

    LUO Jianwen; BAI Jing; SHAO Jinhua

    2006-01-01

    In ultrasound elastography, the axial strain distribution within biological tissues is calculated as the numerical derivative (differentiation) of the estimated axial displacement field. Unfortunately, the numerical derivative is unstable because it can greatly amplify the noises, especially at high frequencies. This work focuses on the axial strain calculation from the estimated axial displacements using wavelet transforms (WTs), including continuous wavelet transforms (CWTs) and discrete wavelet transforms (DWTs). The feasibility of the WT-based method using the quadratic spline function is verified by computer simulations and some phantom data. Results indicate that the WT-based method can effectively reduce the noise amplification in axial strain calculation.

  2. Light fields with an axially expanded intensity distribution for stable three-dimensional optical trapping.

    Science.gov (United States)

    Zwick, Susanne; Schaub, Christian; Haist, Tobias; Osten, Wolfgang

    2010-09-13

    We introduce a new kind of light field to improve and simplify the trapping process of axially displaced particles. To this end we employ a light field with an axially expanded intensity distribution, which at the same time enables stable axial trapping. We present simulations of the axial intensity distribution of the novel trapping field and first experimental results, which demonstrate the improvement of the reliability of the axial trapping process. The method can be used to automate trapping of particles that are located outside of the focal plane of the microscope.

  3. Computed tomography angiography with pulmonary artery thrombus burden and right-to-left ventricular diameter ratio after pulmonary embolism.

    Science.gov (United States)

    Ouriel, Kenneth; Ouriel, Richard L; Lim, Yeun J; Piazza, Gregory; Goldhaber, Samuel Z

    2017-02-01

    Purpose Computed tomography angiography is used for quantifying the significance of pulmonary embolism, but its reliability has not been well defined. Methods The study cohort comprised 10 patients randomly selected from a 150-patient prospective trial of ultrasound-facilitated fibrinolysis for acute pulmonary embolism. Four reviewers independently evaluated the right-to-left ventricular diameter ratios using the standard multiplanar reformatted technique and a simplified (axial) method, and thrombus burden with the standard modified Miller score and a new, refined Miller scoring system. Results The intraclass correlation coefficient for intra-observer variability was .949 and .970 for the multiplanar reformatted and axial methods for estimating right-to-left ventricular ratios, respectively. Inter-observer agreement was high and similar for the two methods, with intraclass correlation coefficient of .969 and .976. The modified Miller score had good intra-observer agreement (intraclass correlation coefficient .820) and was similar to the refined Miller method (intraclass correlation coefficient .883) for estimating thrombus burden. Inter-observer agreement was also comparable between the techniques, with intraclass correlation coefficient of .829 and .914 for the modified Miller and refined Miller methods. Conclusions The reliability of computed tomography angiography for pulmonary embolism was excellent for the axial and multiplanar reformatted methods for quantifying the right-to-left ventricular ratio and for the modified Miller and refined Miller scores for quantifying of pulmonary artery thrombus burden.

  4. Introduction of quantitative and qualitative cornea optical coherence tomography findings induced by collagen cross-linking for keratoconus: a novel effect measurement benchmark

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2013-02-01

    Full Text Available A John Kanellopoulos1,2 George Asimellis11Laservision.gr Institute, Athens, Greece; 2New York University Medical School, New York, NY, USAPurpose: To introduce a novel, noninvasive technique to determine the depth and extent of anterior corneal stroma changes induced by collagen cross-linking (CXL using quantitative analysis of high-resolution anterior-segment optical coherence tomography (OCT post-operative images.Setting: Private clinical ophthalmology practice.Patients and methods: Two groups of corneal cross-sectional images obtained with the OptoVue RTVue anterior-segment OCT system were studied: group A (control consisted of unoperated, healthy corneas, with the exception of possible refractive errors. The second group consisted of keratoconic corneas with CXL that were previously operated on. The two groups were investigated for possible quantitative evidence of changes induced by the CXL, and specifically, the depth, horizontal extent, as well as the cross-sectional area of intrastromal hyper-reflective areas (defined in our study as the area consisting of pixels with luminosity greater than the mean +2 × standard deviation of the entire stromal cross section within the corneal stroma.Results: In all images of the second group (keratoconus patients treated with CXL there was evidence of intrastromal hyper-reflective areas. The hyper-reflective areas ranged from 0.2% to 8.8% of the cross-sectional area (mean ± standard deviation; 3.46% ± 1.92%. The extent of the horizontal hyper-reflective area ranged from 4.42% to 99.2% (56.2% ± 23.35% of the cornea image, while the axial extent (the vertical extent in the image ranged from 40.00% to 86.67% (70.98% ± 7.85%. There was significant statistical difference (P < 0.02 in these values compared to the control group, in which, by application of the same criteria, the same hyper-reflective area (owing to signal noise ranged from 0.00% to 2.51% (0.74% ± 0.63%.Conclusion: Herein, we introduce a

  5. Differences between postmortem computed tomography and conventional autopsy in a stabbing murder case

    Directory of Open Access Journals (Sweden)

    Talita Zerbini

    2014-12-01

    Full Text Available Objective: The aim of the present work is to analyze the differences and similarities between the elements of a conventional autopsy and images obtained from postmortem computed tomography in a case of a homicide stab wound. Method: Comparison between the findings of different methods: autopsy and postmortem computed tomography. Results: In some aspects, autopsy is still superior to imaging, especially in relation to external examination and the description of lesion vitality. However, the findings of gas embolism, pneumothorax and pulmonary emphysema and the relationship between the internal path of the instrument of aggression and the entry wound are better demonstrated by postmortem computed tomography. Conclusions: Although multislice computed tomography has greater accuracy than autopsy, we believe that the conventional autopsy method is fundamental for providing evidence in criminal investigations.

  6. Study on image feature extraction and classification for human colorectal cancer using optical coherence tomography

    Science.gov (United States)

    Huang, Shu-Wei; Yang, Shan-Yi; Huang, Wei-Cheng; Chiu, Han-Mo; Lu, Chih-Wei

    2011-06-01

    Most of the colorectal cancer has grown from the adenomatous polyp. Adenomatous lesions have a well-documented relationship to colorectal cancer in previous studies. Thus, to detect the morphological changes between polyp and tumor can allow early diagnosis of colorectal cancer and simultaneous removal of lesions. OCT (Optical coherence tomography) has been several advantages including high resolution and non-invasive cross-sectional image in vivo. In this study, we investigated the relationship between the B-scan OCT image features and histology of malignant human colorectal tissues, also en-face OCT image and the endoscopic image pattern. The in-vitro experiments were performed by a swept-source optical coherence tomography (SS-OCT) system; the swept source has a center wavelength at 1310 nm and 160nm in wavelength scanning range which produced 6 um axial resolution. In the study, the en-face images were reconstructed by integrating the axial values in 3D OCT images. The reconstructed en-face images show the same roundish or gyrus-like pattern with endoscopy images. The pattern of en-face images relate to the stages of colon cancer. Endoscopic OCT technique would provide three-dimensional imaging and rapidly reconstruct en-face images which can increase the speed of colon cancer diagnosis. Our results indicate a great potential for early detection of colorectal adenomas by using the OCT imaging.

  7. Positron emission tomography / computerized tomography evaluation of primary Hodgkin's disease of liver.

    Science.gov (United States)

    Gota, V S; Purandare, N C; Gujral, S; Shah, S; Nair, R; Rangarajan, V

    2009-01-01

    Occurrence of primary Hodgkin's lymphoma (PHL) of the liver is extremely rare. We report on a case of a 60-year-old male who presented with liver mass and B-symptomatology. Hepatoma or hepatic metastasis from a gastrointestinal primary was initially suspected. Tumor markers like AFP, CEA, Total PSA, and CA-19.9 were within normal limits. Positron Emission Tomography / Computerized Tomography (PET/CT) revealed a large hepatic lesion and a nodal mass in the porta hepatis. A liver biopsy was consistent with Hodgkin's lymphoma. There was complete regression of the hepatic lesion and evidence of shrinkage of the nodal mass following four cycles of chemotherapy. 18F Fluro -de-oxy Glucose (FDG) PET / CT in this case helped in establishing a primary hepatic lymphoma by demonstrating the absence of pathologically hypermetabolic foci in any other nodes or organs. PET / CT scan is a useful adjunct to conventional imaging and histopathology, not only to establish the initial diagnosis, but also to monitor treatment response in PHL.

  8. Design and axial optimization of nuclear fuel for BWR reactors; Diseno y optimizacion axial de combustible nuclear para reactores BWR

    Energy Technology Data Exchange (ETDEWEB)

    Garcia V, M.A

    2006-07-01

    In the present thesis, the modifications made to the axial optimization system based on Tabu Search (BT) for the axial design of BWR fuel type are presented, developed previously in the Nuclear Engineering Group of the UNAM Engineering Faculty. With the modifications what is mainly looked is to consider the particular characteristics of the mechanical design of the GE12 fuel type, used at the moment in the Laguna Verde Nucleo electric Central (CNLV) and that it considers the fuel bars of partial longitude. The information obtained in this thesis will allow to plan nuclear fuel reloads with the best conditions to operate in a certain cycle guaranteeing a better yield and use in the fuel burnt, additionally people in charge in the reload planning will be favored with the changes carried out to the system for the design and axial optimization of nuclear fuel, which facilitate their handling and it reduces their execution time. This thesis this developed in five chapters that are understood in the following way in general: Chapter 1: It approaches the basic concepts of the nuclear energy, it describes the physical and chemical composition of the atoms as well as that of the uranium isotopes, the handling of the uranium isotope by means of the nuclear fission until arriving to the operation of the nuclear reactors. Chapter 2: The nuclear fuel cycle is described, the methods for its extraction, its conversion and its enrichment to arrive to the stages of the nuclear fuel management used in the reactors are described. Beginning by the radial design, the axial design and the core design of the nuclear reactor related with the fuel assemblies design. Chapter 3: the optimization methods of nuclear fuel previously used are exposed among those that are: the genetic algorithms method, the search methods based on heuristic rules and the application of the tabu search method, which was used for the development of this thesis. Chapter 4: In this part the used methodology to the

  9. Dynamic 3D computed tomography scanner for vascular imaging

    Science.gov (United States)

    Lee, Mark K.; Holdsworth, David W.; Fenster, Aaron

    2000-04-01

    A 3D dynamic computed-tomography (CT) scanner was developed for imaging objects undergoing periodic motion. The scanner system has high spatial and sufficient temporal resolution to produce quantitative tomographic/volume images of objects such as excised arterial samples perfused under physiological pressure conditions and enables the measurements of the local dynamic elastic modulus (Edyn) of the arteries in the axial and longitudinal directions. The system was comprised of a high resolution modified x-ray image intensifier (XRII) based computed tomographic system and a computer-controlled cardiac flow simulator. A standard NTSC CCD camera with a macro lens was coupled to the electro-optically zoomed XRII to acquire dynamic volumetric images. Through prospective cardiac gating and computer synchronized control, a time-resolved sequence of 20 mm thick high resolution volume images of porcine aortic specimens during one simulated cardiac cycle were obtained. Performance evaluation of the scanners illustrated that tomographic images can be obtained with resolution as high as 3.2 mm-1 with only a 9% decrease in the resolution for objects moving at velocities of 1 cm/s in 2D mode and static spatial resolution of 3.55 mm-1 with only a 14% decrease in the resolution in 3D mode for objects moving at a velocity of 10 cm/s. Application of the system for imaging of intact excised arterial specimens under simulated physiological flow/pressure conditions enabled measurements of the Edyn of the arteries with a precision of +/- kPa for the 3D scanner. Evaluation of the Edyn in the axial and longitudinal direction produced values of 428 +/- 35 kPa and 728 +/- 71 kPa, demonstrating the isotropic and homogeneous viscoelastic nature of the vascular specimens. These values obtained from the Dynamic CT systems were not statistically different (p less than 0.05) from the values obtained by standard uniaxial tensile testing and volumetric measurements.

  10. Under-reporting of osteoporotic vertebral fractures on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Alexandra L. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester (United Kingdom)], E-mail: alexandra.firth@virgin.net; Al-Busaidi, Aisha [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester (United Kingdom)], E-mail: albusaidi@doctors.org.uk; Sparrow, Patrick J. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester (United Kingdom)], E-mail: patsparrow@doctors.org.uk; Adams, Judith E. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester (United Kingdom); Department of Clinical Radiology, Imaging Science and Biomedical Engineering, Stopford Building, , University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom)], E-mail: judith.adams@manchester.ac.uk; Whitehouse, Richard W. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester (United Kingdom)], E-mail: Richard.Whitehouse@cmmc.nhs.uk

    2009-01-15

    Purpose: Osteoporotic vertebral fractures are frequently asymptomatic. They are often not diagnosed clinically or radiologically. Despite this, prevalent osteoporotic vertebral fractures predict future osteoporotic fractures and are associated with increased mortality and morbidity. Appropriate management of osteoporosis can reduce future fracture risk. Fractures on lateral chest radiographs taken for other conditions are frequently overlooked by radiologists. Our aim was to assess the value of computed tomography (CT) in the diagnosis of vertebral fracture and identify the frequency with which significant fractures are missed. Materials and methods: The thoracic CT scans of 100 consecutive male and 100 consecutive female patients over 55 years were reviewed. CT images were acquired on General Electric Lightspeed multi-detector (MD) CT scanners (16 or 32 row) using 1.25 mm slice thickness. Midline sagittal images were reconstructed from the 3D volume images. The presence of moderate (25-40% height loss) or severe (>40% height loss) vertebral fractures between T1 and L1 was determined using an established semi-quantitative method and confirmed by morphological measurement. Results were compared with the formal CT report. Results: Scans of 192 patients were analysed (95 female; 97 male); mean age 70.1 years. Thirty-eight (19.8%) patients had one or more moderate to severe vertebral fractures. Only 5 (13%) were correctly reported as having osteoporotic fractures in the official report. The sensitivity of axial CT images to vertebral fracture was 0.35. Conclusion: Incidental osteoporotic vertebral fractures are under-reported on CT. The sensitivity of axial images in detecting these fractures is poor. Sagittal reformations are strongly recommended to improve the detection rate.

  11. Cranial computed tomography in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Boltshauser, E. (Zuerich Univ. (Switzerland). Kinderklinik)

    1984-01-01

    This paper deals mainly with methodical aspects (such as sedation, intravenous and intrathecal application of contrast media) and with common difficulties in interpretation of computed tomography images. The indications for cranial CT are discussed in respect to probable therapeutic consequences and expected diagnostic yield. In the view of the author CT is, as a rule, not required in assessing chronic headache, generalised epileptic convulsions, non-specific mental retardation and cerebral palsy.

  12. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  13. Computerized tomography. Yesterday and today

    Energy Technology Data Exchange (ETDEWEB)

    Ethier, R.; Melanson, D. (Montreal Neurological Inst., Quebec (Canada))

    1983-10-01

    This presentation describes the evolution of computerized tomography over the past decade and its contribution to the radiologic investigation of neurologic disorders. This new technique has not only stimulated development in the diagnosis of cerebral diseases, but the whole body as well. Detailed investigation of the spine, spinal cord, sella turcica, the orbits, as well as the petrous pyramids has been made possible through the development of high resolution scanning.

  14. Classification of temporal bone pneumatization based on sigmoid sinus using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Han, S.-J. [Department of Otorhinolaryngology, National Health Insurance Corporation Ilsan Hospital, Seoul (Korea, Republic of); Song, M.H. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Kim, J. [Department of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, W.-S. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Lee, H.-K. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of)], E-mail: hoki@yuhs.ac

    2007-11-15

    Aim: To analyse several reference structures using axial computed tomography (CT) imaging of the temporal bone, which may reflect pneumatization of the entire temporal bone by statistical correlation to the actual volume of the temporal bone measured using three-dimensional reconstruction. Materials and methods: One hundred and sixteen temporal bones were studied, comprising 48 with normal findings and 68 sides showing chronic otitis media or temporal bone fracture. After measuring the volume of temporal bone air cells by the volume rendering technique using three-dimensional reconstruction images, classification of temporal bone pneumatization was performed using various reference structures on axial images to determine whether significant differences in the volume of temporal bone air cells could be found between the groups. Results: When the sigmoid sinus at the level of the malleoincudal complex was used in the classification, there were statistically significant differences between the groups that correlated with the entire volume of the temporal bone. Grouping based on the labyrinth and the ascending carotid artery showed insignificant differences in volume. Furthermore, there was no significant correlation between the cross-sectional area of the antrum and the entire volume of the temporal bone. Conclusion: The degree of pneumatization of temporal bone can be estimated easily by the evaluation of the air cells around the sigmoid sinus on axial CT images.

  15. Application of maximum-likelihood estimation in optical coherence tomography for nanometer-class thickness estimation

    Science.gov (United States)

    Huang, Jinxin; Yuan, Qun; Tankam, Patrice; Clarkson, Eric; Kupinski, Matthew; Hindman, Holly B.; Aquavella, James V.; Rolland, Jannick P.

    2015-03-01

    In biophotonics imaging, one important and quantitative task is layer-thickness estimation. In this study, we investigate the approach of combining optical coherence tomography and a maximum-likelihood (ML) estimator for layer thickness estimation in the context of tear film imaging. The motivation of this study is to extend our understanding of tear film dynamics, which is the prerequisite to advance the management of Dry Eye Disease, through the simultaneous estimation of the thickness of the tear film lipid and aqueous layers. The estimator takes into account the different statistical processes associated with the imaging chain. We theoretically investigated the impact of key system parameters, such as the axial point spread functions (PSF) and various sources of noise on measurement uncertainty. Simulations show that an OCT system with a 1 μm axial PSF (FWHM) allows unbiased estimates down to nanometers with nanometer precision. In implementation, we built a customized Fourier domain OCT system that operates in the 600 to 1000 nm spectral window and achieves 0.93 micron axial PSF in corneal epithelium. We then validated the theoretical framework with physical phantoms made of custom optical coatings, with layer thicknesses from tens of nanometers to microns. Results demonstrate unbiased nanometer-class thickness estimates in three different physical phantoms.

  16. Foreign-catalyst-free growth of InAs/InSb axial heterostructure nanowires on Si (111) by molecular-beam epitaxy.

    Science.gov (United States)

    So, Hyok; Pan, Dong; Li, Lixia; Zhao, Jianhua

    2017-03-01

    Epitaxial high-quality InAs/InSb axial heterostructure nanowires are of great interest due to their distinct advantages in fundamental research as well as applications in semiconductor electronic and quantum devices. Currently, nearly all the growth of InAs/InSb axial heterostructure nanowires is assisted with foreign catalysts such as Au, and work on foreign-catalyst-free growth of InAs/InSb axial heterostructure nanowires is lacking. Here we report on the growth of InAs/InSb axial heterostructure nanowires on Si (111) substrates by molecular-beam epitaxy without using any foreign catalysts. The Sb/In beam equivalent pressure (BEP) ratio is found to have important influence on the heterostructure nanowire morphology, and InSb nanowires can be epitaxially grown on InAs nanowire stems with a hexagonal prism and nanosheet-like shapes when the Sb/In BEP ratio varies from 10 to 20. Transmission electron microscopy studies reveal that the InAs nanowire stems have a mixture of zincblende (ZB) and wurtzite (WZ) crystal structures, while InSb nanowire parts have a pure ZB crystal structure free of stacking faults. Composition analysis of axial heterostructure nanowires provides clear evidence that the InSb nanowires are epitaxially grown on InAs nanowires in an In self-assisted vapor-liquid-solid manner. This study paves a new route for growing narrow-gap semiconductor heterostructures with strong spin-orbit interaction for the study of topological states, and the growth manner presented here is expected to be used to grow other In-based axial heterostructure nanowires.

  17. Condylus tertius with atlanto-axial rotatory fixation: an unreported association

    Energy Technology Data Exchange (ETDEWEB)

    Udare, Ashlesha Satish [M.G.M. Hospital, Department of Radiology, Kamothe, Navi Mumbai (India); Global Hospital Super Speciality and Transplant Centre, Department of Radiology, Mumbai (India); Navi Mumbai, Maharashtra (India); Bansal, Divya; Patel, Bhavin [M.G.M. Hospital, Department of Radiology, Kamothe, Navi Mumbai (India); Mondel, Prabath Kumar [P.D. Hinduja Hospital, Department of Radiology, Mahim, Mumbai (India); Aiyer, Siddharth [Shatabdi Hospital, Department of Orthopedics, Chembur, Mumbai (India)

    2014-04-15

    The ''condylus tertius'' or the ''third occipital condyle'' is an embryological remnant of the proatlas sclerotome. Anatomically, it is attached to the basion and often articulates with the anterior arch of the atlas and the odontoid apex; hence, it is also called the ''median occipital condyle''. It is a rare anomaly of the cranio-vertebral junction (CVJ) that can lead to instability and compression of important surrounding neurovascular structures. We report a case of a 16-year-old boy who presented with suboccipital neck pain, torticollis and right sided hemiparesis. Plain radiographs revealed an increased atlanto-dental interspace (ADI) with a retroflexed odontoid. Open mouth view showed asymmetry of the articular processes of the atlas with respect to the dens. Computed tomography (CT) of the CVJ delineated the third occipital condyle. Furthermore, on dynamic CT study, a type 3 atlanto-axial rotatory fixation (AARF) was clearly demonstrated. Magnetic resonance imaging (MRI) of the CVJ revealed severe right-sided spinal cord compression by the retroflexed and rightward deviated dens. It also revealed disruption of the left alar and transverse ligaments. The patient was treated with 8 weeks of cranial traction and reasonable alignment was obtained. This was followed by C1-C2 lateral mass screw fixation and C1-C2 interlaminar wiring to maintain the alignment. A review of the literature did not reveal any cases of condylus tertius associated with non-traumatic AARF. An accurate knowledge of the embryology and imaging features of this rare CVJ anomaly is useful in the prompt diagnosis and management of such patients. (orig.)

  18. Alendronate increases BMD at appendicular and axial skeletons in patients with established osteoporosis

    Directory of Open Access Journals (Sweden)

    Au Szeki

    2007-05-01

    Full Text Available Abstract Background To identify high-risk patients and provide pharmacological treatment is one of the effective approaches in prevention of osteoporotic fractures. This study investigated the effect of 12-month Alendronate treatment on bone mineral density (BMD and bone turnover biochemical markers in postmenopausal women with one or more non-traumatic fractures, i.e. patients with established osteoporosis. Methods A total of 118 Hong Kong postmenopausal Chinese women aged 50 to 75 with low-energy fracture at distal radius (Colles' fracture were recruited for BMD measurement at lumbar spine and non-dominant hip using Dual-Energy X-ray Absorptiometry (DXA. 47 women with BMD T-score below -2 SD at either side were identified as patients with established osteoporosis and then randomized into Alendronate group (n = 22 and placebo control group (n = 25 for BMD measurement at spine and hip using DXA and distal radius of the non-fracture side by peripheral quantitative computed tomography (pQCT, and bone turnover markers, including bone forming alkaline phosphatase (BALP and bone resorbing urinary Deoxypyridinoline (DPD. All measurements were repeated at 6 and 12 months. Results Alendronate treatment significantly increased BMD, more in weight-bearing skeletons (5.1% at spine and 2.5% at hip than in non-weight bearing skeleton (0.9% at distal radius after 12 months treatment. Spine T-score was significant improved in Alendronate group (p Conclusion 12 months Alendronate treatment was effective to increase BMD at both axial and appendicular skeletons in postmenopausal women with established osteoporosis.

  19. Computed tomography in the foramen magnum and high cervical cord lesion

    Energy Technology Data Exchange (ETDEWEB)

    Isu, T.; Ito, T.; Iwasaki, Y.; Tsuru, M. (Hokkaido Univ., Sapporo (Japan). School of Medicine); Kitaoka, K.

    1981-10-01

    The value of computed tomography in the spine and spinal cord disease recently has been well documented. However, little attention is made to the role of computed tomography in foramen magnum and high cervical cord lesion. We report 16 cases of the foramen magnum and high cervical cord lesion. Method: Either EMI Head Scanner, CT 1010 (slice thickness 10 mm) or EMI Whole Body Scanner, CT 5005 (slice thickness 13 mm) was used. In 9 cases enhanced CT with intravenous injection of contrast medium was performed. Eleven cases received intrathecal injection of metrizamide. Materials: 1) control group without cervical pathology 70 cases, 2) spinal cord tumor 6 cases, 3) atlanto-axial dislocation 6 cases, 4) Chiari malformation (type 1) 3 cases, 5) spinal foreign body (acupuncture needle) 1 case. Results: 1. plain CT. 1) In control group without cervical pathology the cervical cord at C/sub 1/ level was seen as area surrounded by ring of subarachnoid space. 2) In 14 cases except for 1 case of atlanto-axial dislocation and 1 case of spinal foreign body identification of the cervical cord at C/sub 1/ level was impossible. 3) CT was of diagnostic value in detecting altanto-axial dislocation and spinal foreign body. 2. enhanded CT. Meningioma and neurinoma showed positive contrast enhancement. However, astrocytoma and herniated cerebellar tonsils were not detectable. 3. CT metrizamide myelography visualized the subarachnoid space and made it possible to localize the lesion in the spinal canal in relation to the spinal cord. Conclusion: Attention should be given to plain CT finding at C/sub 1/ level in diagnosis of foramen magnum and high cervical cord lesion. If identification of cervical cord at C/sub 1/ level is impossible, it is suspected that subarachnoid space is blocked by the lesion, and enhanced CT and CT metrizamide myelography must be performed.

  20. Ingestion into the upstream wheelspace of an axial turbine stage

    Science.gov (United States)

    Green, T.; Turner, A. B.

    1994-04-01

    The upstream wheelspace of an axial air turbine stage complete with nozzle guide vanes (NGVs) and rotor blades (430 mm mean diameter) has been tested with the objective of examining the combined effect of NGVs and rotor blades on the level of mainstream ingestion for different seal flow rates. A simple axial clearance seal was used with the rotor spun up to 6650 rpm by drawing air through it from atmospheric pressure with a large centrifugal compressor. The effect of rotational speed was examined for several constant mainstream flow rates by controlling the rotor speed with an air brake. The circumferential variation in hub static pressure was measured at the trailing edge of the NGVs upstream of the seal gap and was found to affect ingestion significantly. The hub static pressure distribution on the rotor blade leading edges was rotor speed dependent and could not be measured in the experiments. The Denton three-dimensional CFD computer code was used to predict the smoothed time-dependent pressure field for the rotor together with the pressure distribution downstream of the NGVs. The level and distribution of mainstream ingestion, and thus, the seal effectiveness, was determined from nitrous oxide gas concentration measurements and related to static pressure measurements made throughout the wheelspace. With the axial clearance rim seal close to the rotor the presence of the blades had a complex effect. Rotor blades in connection with NGVs were found to reduce mainstream ingestion seal flow rates significantly, but a small level of ingestion existed even for very high levels of seal flow rate.