WorldWideScience

Sample records for axial tomography evidence

  1. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  2. Computerized axial tomography in clinical pediatrics.

    Science.gov (United States)

    McCullough, D C; Kufta, C; Axelbaum, S P; Schellinger, D

    1977-02-01

    Computerized axial tomography (CAT), a noninvasive radiologie method, provides a new dimension in screening and diagnosis of intracranial pathology. Evaluation of 725 scans in infants and children demonstrates that CAT may be performed with negligible risk, although sedation and restraint are essential to the successful performance of studies in children under 6 years of age. CAT is the preferred initial diagnostic method in suspected hydrocephalls and is accurate in the detection and precise localization of brain tumors. The management of hydrocephalus and brain tumors has been significantly altered by the availability of CAT. Few invasive neuroradiologic procedures are required and pneumography is especially curtailed. Serial scanning is the best available method of monitoring ventricular alterations in hydrocephalus, tumor size during radiotherapy or chemotherapy, and postoperative recurrence of benign neoplasms. Complex intracranial anomalies are detectable with computerized tomography, but complete definition of pathology often requires angiography and air studies. Limited clinical experience in detecting neonatal intraventricular hemorrhage suggests that CAT will be a valuable tool for futlre investigations of that problem.

  3. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  4. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  5. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient

  6. Axial myopia in computed and magnetic resonance tomography

    Energy Technology Data Exchange (ETDEWEB)

    Beyer-Enke, S.A.; Goerich, J.; Gamroth, A.

    1987-08-01

    The case of a 44-year old woman suffering from amblyopia on the left eye with unilateral proptosis caused by axial (progressive) myopia is presented. The clinical and radiological findings were discussed in reference to the literature. The diagnosis was established by ruling out neoplastic, inflammatory or endocrine causes for the exophtalmos. CT and MR scans revealed an enlarged left globe without evidence of orbital masses. The findings were regarded as typical for the diagnosis at axial myopia.

  7. A review of X-ray computed axial tomography

    International Nuclear Information System (INIS)

    A review of Computed axial tomography (CAT) scanning literature outlining the theoretical and practical aspects of this technique with application in both medical diagnosis and industrial non-destructive inspection (NDI) is presented. Practical aspects of CAT scanning discussed include : radiation sources, currently available spatial and contrast resolution limits and the evolution of the computerized tomography (CT) system. It was found that monochromatic gamma rays are preferred to X-rays, especially for very high density materials, and that in medical CAT scanning, the special resolution is only, 0.5 mm while spatial resolutions of less than 50μm have been achieved in NDI. An increased number of scientific and industrial applications are anticipated (e.g. for studying sintering reactions), as the capital cost of CAT scanning decreased. 13 refs., 9 figs., 2 tabs

  8. Development of Axial Tomography for Steam Explosion Study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Young; Seo, Shi Won [HanDong Global University, Pohang (Korea, Republic of); Song, Jin Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    Visual understanding of complicated system leads us often to the intuitive enlightenment of the invisible causes of the effect. When it is formulated based on the rigorous mathematics, the produced formula or correlation will be very useful in design and analysis of the engineering system. In this point of view, the tomography technology can be a tool to meet such a purpose. However, the traditional hard ray tomography using high energy radiation cannot meet the case due to heavy shielding structure which obstructs access of the sensing unit to the very complicated and limited space. Therefore, the recent development of the electric tomography is noteworthy in the application to the industrial process monitoring. It has the merit not only of low cost but also of easier access to the limited space than the hard ray tomography.

  9. Investigations of the radiation exposure of the head during computerized axial tomography

    International Nuclear Information System (INIS)

    Various head phantoms and patients were used to measure, by means of thermoluminescence and film dosimetry, the radiation exposure of the head, especially of the eye lenses, in computerized axial tomography with the EMI scanner. The form of the isodoses and the dependence on position of the exposure dose in the region of the eyes were confirmed by calculations with a computer program. (orig.)

  10. Time-Domain Terahertz Computed Axial Tomography NDE System

    Science.gov (United States)

    Zimdars, David

    2012-01-01

    NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D

  11. Semi-axial view by computed tomography. A new projection to the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Akai, Sadayasu; Hashimoto, Hiroaki; Kano, Yuji; Yamada, Osamu; Suzuki, Jun-ichi

    1983-09-01

    The efficiency of the semi-axial view, which is a new projection of computed tomography (CT) for the temporal bone, was evaluated through the study of 48 normal and 55 pathological ears. The semi-axial view is obtained by the technique that X-ray segment is inclined 30 degrees below the Cantho-meatal line to the nose. The results were as follows: the pictures of the semi-axial view were extremely similar to horizontal series of temporal bone specimen and facilitated understanding of the surgical anatomy; the pathology as well as morphology in the middle ear, especially from the eustachian tube to the antrum, was detected; the head position during the examination did not cause discomfort to the patient; the radiation dose to the lens in the semi-axial view was very low. These results indicate that the semi-axial view by CT can be applied to the routine X-ray test for detecting abnormalities the temporal bone.

  12. Analysis and calibration of stage axial vibration for synchrotron radiation nanoscale computed tomography.

    Science.gov (United States)

    Fu, Jian; Li, Chen; Liu, Zhenzhong

    2015-10-01

    Synchrotron radiation nanoscale computed tomography (SR nano-CT) is a powerful analysis tool and can be used to perform chemical identification, mapping, or speciation of carbon and other elements together with X-ray fluorescence and X-ray absorption near edge structure (XANES) imaging. In practical applications, there are often challenges for SR nano-CT due to the misaligned geometry caused by the sample stage axial vibration. It occurs quite frequently because of experimental constraints from the mechanical error of manufacturing and assembly and the thermal expansion during the time-consuming scanning. The axial vibration will lead to the structure overlap among neighboring layers and degrade imaging results by imposing artifacts into the nano-CT images. It becomes worse for samples with complicated axial structure. In this work, we analyze the influence of axial vibration on nano-CT image by partial derivative. Then, an axial vibration calibration method for SR nano-CT is developed and investigated. It is based on the cross correlation of plane integral curves of the sample at different view angles. This work comprises a numerical study of the method and its experimental verification using a dataset measured with the full-field transmission X-ray microscope nano-CT setup at the beamline 4W1A of the Beijing Synchrotron Radiation Facility. The results demonstrate that the presented method can handle the stage axial vibration. It can work for random axial vibration and needs neither calibration phantom nor additional calibration scanning. It will be helpful for the development and application of synchrotron radiation nano-CT systems. PMID:26265032

  13. Analysis and calibration of stage axial vibration for synchrotron radiation nanoscale computed tomography.

    Science.gov (United States)

    Fu, Jian; Li, Chen; Liu, Zhenzhong

    2015-10-01

    Synchrotron radiation nanoscale computed tomography (SR nano-CT) is a powerful analysis tool and can be used to perform chemical identification, mapping, or speciation of carbon and other elements together with X-ray fluorescence and X-ray absorption near edge structure (XANES) imaging. In practical applications, there are often challenges for SR nano-CT due to the misaligned geometry caused by the sample stage axial vibration. It occurs quite frequently because of experimental constraints from the mechanical error of manufacturing and assembly and the thermal expansion during the time-consuming scanning. The axial vibration will lead to the structure overlap among neighboring layers and degrade imaging results by imposing artifacts into the nano-CT images. It becomes worse for samples with complicated axial structure. In this work, we analyze the influence of axial vibration on nano-CT image by partial derivative. Then, an axial vibration calibration method for SR nano-CT is developed and investigated. It is based on the cross correlation of plane integral curves of the sample at different view angles. This work comprises a numerical study of the method and its experimental verification using a dataset measured with the full-field transmission X-ray microscope nano-CT setup at the beamline 4W1A of the Beijing Synchrotron Radiation Facility. The results demonstrate that the presented method can handle the stage axial vibration. It can work for random axial vibration and needs neither calibration phantom nor additional calibration scanning. It will be helpful for the development and application of synchrotron radiation nano-CT systems.

  14. Donkey dental anatomy. Part 1: Gross and computed axial tomography examinations.

    Science.gov (United States)

    Du Toit, N; Kempson, S A; Dixon, P M

    2008-06-01

    Post-mortem examination of 19 donkey skulls showed that donkeys have a greater degree of anisognathia (27% width difference between upper and lower jaws) compared to horses (23%). Teeth (n=108) were collected from 14 skulls and examined grossly and by computed axial tomography (CAT). A greater degree of peripheral enamel infolding was found in mandibular cheek teeth (CT) compared to maxillary CT (P16 years) than in the younger (dental anatomy was shown to be largely similar to that described in horses.

  15. X-ray detectors in axial computed tomography development; Sensori di radiazioni X negli sviluppi della tomografia assiale computerizzata

    Energy Technology Data Exchange (ETDEWEB)

    Gislon, R.; Imperiali, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione

    1996-12-01

    The increase of potentially of axial computed tomography as a non destructive investigation method in industrial field is particularly tied to the development of the X-rays detectors. The transition from the first gas ionization detectors to the last semiconductor detectors has indeed dramatically increased the performances of tomographic systems. In this report, after a quick analysis of fundamental principles of tomography, the most significant parameters for a detector to be used in a tomographic system are reviewed. The examination of the principal kinds of detectors that have been up to now used, with their working schemes, allows to delineate their characteristics and so to compare them with the ideal detector sketched above. The necessity of using high definition arrays brings to put into evidence the inadequacy of both gas and liquid ionization detectors and also of those types of light conversion devices which utilize for signal amplification a photomultiplier tube. Systems based on charge coupled devices or on a light conversion obtained with semiconductor photodiode arrays are definitely to be preferred. The progress of the last years in microelectronic technologies has brought great improvements in this field.

  16. Value of the computerized axial tomography for early diagnosis of cranio cerebral trauma

    International Nuclear Information System (INIS)

    A descriptive and cross-sectional study was conducted in 62 patients with cranio cerebral trauma admitted to 'Saturnino Lora' Provincial Teaching Hospital of Santiago de Cuba, from January 2005 to May 2006, in whom computerized axial tomography indicated at the emergency room was performed with the purpose of evaluating the effectiveness of this radiographic technique for early diagnosis of the injury. In the case material there was neither association between the source and imaging results, nor between the age and sex. The main clinical manifestations were vomiting, headache and motor deficit as well as frontal location, intraparenchymatous hematoma (the latter as the most common image finding) and the hyperdense area as tomographic pattern. The survival was of 91,9%

  17. Spectral estimation optical coherence tomography for axial super-resolution (Conference Presentation)

    Science.gov (United States)

    Liu, Xinyu; Yu, Xiaojun; Wang, Nanshuo; Bo, En; Luo, Yuemei; Chen, Si; Cui, Dongyao; Liu, Linbo

    2016-03-01

    The sample depth reflectivity profile of Fourier domain optical coherence tomography (FD-OCT) is estimated from the inverse Fourier transform of the spectral interference signals (interferograms). As a result, the axial resolution is fundamentally limited by the coherence length of the light source. We demonstrate an axial resolution improvement method by using the autoregressive spectral estimation technique to instead of the inverse Fourier transform to analyze the spectral interferograms, which is named as spectral estimation OCT (SE-OCT). SE-OCT improves the axial resolution by a factor of up to 4.7 compared with the corresponding FD-OCT. Furthermore, SE-OCT provides a complete sidelobe suppression in the point-spread function. Using phantoms such as an air wedge and micro particles, we prove the ability of resolution improvement. To test SE-OCT for real biological tissue, we image the rat cornea and demonstrate that SE-OCT enables clear identification of corneal endothelium anatomical details ex vivo. We also find that the performance of SE-OCT is depended on SNR of the feature object. To evaluate the potential usage and define the application scope of SE-OCT, we further investigate the property of SNR dependence and the artifacts that may be caused. We find SE-OCT may be uniquely suited for viewing high SNR layer structures, such as the epithelium and endothelium in cornea, retina and aorta. Given that SE-OCT can be implemented in the FD-OCT devices easily, the new capabilities provided by SE-OCT are likely to offer immediate improvements to the diagnosis and management of diseases based on OCT imaging.

  18. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  19. Regional myocardial perfusion assessed by N-13 labeled ammonia and positron emission computerized axial tomography

    International Nuclear Information System (INIS)

    The usefulness of 13NH3 as an indicator of regional myocardial perfusion suitable for positron emission computerized axial tomography (PCT) has been suggested. However, the relationship between myocardial blood flow and uptake of 13NH3 has not been examined quantitatively. It was therefore the purpose of the current investigation to quantitate the relationship of myocardial 13NH3 tissue concentration to myocardial blood flow and to examine its suitability for PCT imaging. Twelve open chest dogs were studied. In 8 of the dogs 25 imaging procedures with 13NH3 and PCT were performed. In the remaining four dogs the relationship between flow and myocardial 13NH3 tissue concentration was assessed by in vitro techniques. The PCT technique provided high quality cross-sectional images of the distribution of 13NH3 in left ventricular myocardium. No significant redistribution of 13NH3 in myocardium occurred with time. Alterations in regional myocardial blood flow resulted in changes of the regional distribution of 13NH3 that were readily appreciated on the PCT images

  20. [Correlation between diagnostic hypothesis and result of cranial computed axial tomography].

    Science.gov (United States)

    Nóvak, E M; Terabe, F; Nasimoto, A L; Carvalho, P H; Loper, A D; Büchele, F S; Nogara, J C

    2001-09-01

    The use of computed axial tomography (CT) in the investigation of neurologic disorders is attractive for its disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 +/- 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36.2%), Emergency room (17.4%), Pediatric Neurology (16.9%) and Internal Medicine (5.9%). The CT was more indicated in cases of seizures (30%), headache (26.2%), motor impairment (20.2%) and reduction of conscience level (16.9%). The main hypothetic diagnosis were "to discard anatomic lesions" (9.0%), not specified stroke (8.2%) and neurocisticercosis (8.2%). The result of the CT was normal in 50.4% of the exams specially those requested in cases of headache (94.4%), seizures (71.4%) and "to discard anatomic lesions"(66.7%). The more frequently CT abnormalities were hydrocephalus (5.4%), ischemic stroke (5.4%) and neoplasm (3.5%) The greatest rates of correlation were among those to discard anatomic lesions (66,7%), hydrocephalus (50%), ischemic stroke (50%) and hematoma (50%). We concluded that CT is more helpful if more clinical data is provided in the request form, so aiding the radiologist in the final report.

  1. Development of analysis and processing programs for the numerical diagnosis of head by computed axial tomography

    International Nuclear Information System (INIS)

    The series of basic processing programs for the numerical diagnosis of head by computed axial tomography (CT) were developed as one step connecting to the future automatic screening and diagnosis. The system for this CT numerical processing, consisting of the computer EMI 1010, the mini-computer ECLIPSE S/200, the real time disc operating system (RDOS) and the CRT, is presented. As for the basic programs, the transmission of picture data to the disc (TTRDQ), the picture output (NGRPIC), the noise elimination outside skulls (ERATF), the smoothing process (SM 9PIC), the statistical quantity in the interesting region (ROISTAT), the statistical values of whole pictures (GRSTAT), the measurement of the symmetry of pictures (NCGAPIC), the parallel movement of pictures (MVPIC), the subtraction (SBPIC), the reconstruction of pictures (RCONST) and the Sigma-scan (SIGMASCAN) are explained, showing the many experimental data and pictures, such as the format of the print-out program NGRPIC, the picture of the cross section of a brain, the output data of the statistical quantity in the interesting region ROISTAT, the calculating formula of CGAPIC and the histogram, the picture of a tumor of meninx in a brain utilizing SM9PIC, etc. The pictures utilizing RCONST and slicing a brain into 5 mm thickness, and the pictures of a brain utilizing SIGMASCAN. These pictures were taken out as the output with a line printer. These programs were designed originally, and the characteristics of these programs are explained, especially about the special print-out, the peripheral correction for partial volume effect, the calculation of CT-Weight and the skull elimination. The future effective diagnosis is expected by this program. (Nakai, Y.)

  2. [Correlation between diagnostic hypothesis and result of cranial computed axial tomography].

    Science.gov (United States)

    Nóvak, E M; Terabe, F; Nasimoto, A L; Carvalho, P H; Loper, A D; Büchele, F S; Nogara, J C

    2001-09-01

    The use of computed axial tomography (CT) in the investigation of neurologic disorders is attractive for its disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 +/- 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36.2%), Emergency room (17.4%), Pediatric Neurology (16.9%) and Internal Medicine (5.9%). The CT was more indicated in cases of seizures (30%), headache (26.2%), motor impairment (20.2%) and reduction of conscience level (16.9%). The main hypothetic diagnosis were "to discard anatomic lesions" (9.0%), not specified stroke (8.2%) and neurocisticercosis (8.2%). The result of the CT was normal in 50.4% of the exams specially those requested in cases of headache (94.4%), seizures (71.4%) and "to discard anatomic lesions"(66.7%). The more frequently CT abnormalities were hydrocephalus (5.4%), ischemic stroke (5.4%) and neoplasm (3.5%) The greatest rates of correlation were among those to discard anatomic lesions (66,7%), hydrocephalus (50%), ischemic stroke (50%) and hematoma (50%). We concluded that CT is more helpful if more clinical data is provided in the request form, so aiding the radiologist in the final report. PMID:11593279

  3. Discrepancies in determination of abdominal aortic aneurysms maximum diameter and growth rate, using axial and orhtogonal computed tomography measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kontopodis, Nikolaos, E-mail: kontopodisn@yahoo.gr [Department of Vascular Surgery, University of Crete Medical School, Heraklion (Greece); Metaxa, Eleni, E-mail: emmetaxa@gmail.com [Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, Heraklion, Crete (Greece); Gionis, Michalis, E-mail: gkionismichalis@yahoo.gr [Department of Vascular Surgery, University of Crete Medical School, Heraklion (Greece); Papaharilaou, Yannis, E-mail: yannisp@iacm.forth.gr [Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, Heraklion, Crete (Greece); Ioannou, Christos V., E-mail: ioannou@med.uoc.gr [Department of Vascular Surgery, University of Crete Medical School, Heraklion (Greece)

    2013-09-15

    Purpose: Maximum diameter and growth rate of abdominal aortic aneurysms (AAAs) which are currently used as the only variables to set the indication for elective repair are recorded through computed tomography (CT) measurements on an axial plane or on an orthogonal plane that is perpendicular to vessel centerline, interchangeably. We will attempt to record possible discrepancies between the two methods, identify whether such differences could influence therapeutic decisions and determine in which cases this should be expected. Materials and methods: We retrospectively reviewed sixty CT-scans performed in thirty-nine patients. Three-dimensional reconstruction of AAAs has been performed and differences in maximum diameter measured on axial and orthogonal planes were recorded. A measure for asymmetry was introduced termed ShapeIndex defined as the value of section minor over major axis and was related with differences in maximum diameter recordings. Growth rates were also determined using both axial and orthogonal measurements. Results: Axial measurements overestimate maximum diameter by 2 ± 2.7 mm (P < 0.001) with a range of 0–12.3 mm. Overall, 20% of the CTs had an axial maximum diameter >5.5 cm indicating the need for intervention whereas, orthogonal diameter was below that threshold. Asymmetry of the axial sections with ShapeIndex ≤ 0.8 was found to be related to an overestimation of maximum diameter by >5 mm. There were no significant differences in growth rates when determined using orthogonal or axial measurements in both examinations (median growth rate: 2.3 mm and 3.3 mm respectively P = 0.2). However there were significant differences when orthogonal measurements were used at initial and axial measurements used at follow-up examination or vice versa (median growth rate: 4.9 mm and 0.9 mm respectively P < 0.001). Conclusions: Although the mean difference between measurements is low there is a wide range among cases, mainly observed in asymmetrical AAAs

  4. Radiation dose to the head, and particularly to the lens of the eye, during axial tomography with the EMI scanner

    International Nuclear Information System (INIS)

    Radiation dose to the lens of the eye was estimated using thermoluminescence and film dosimetry on patients undergoing computerised axial skull tomography with the EMI scanner, and also on various phantoms. The dose decreases from the lateral margin of the right eye to the lateral margin of the left eye. During conventional three-layer tomography, maximal exposure of the eye is about 0.6 R (1.55 x 10-4 C x kg-1), produced entirely by scatter. Direct irradiation of the plane of the orbits produces a maximal exposure rate of 3 R (7.7 x 10-4 C x kg-1). Maximal dose to the head depends on skull size and is about 4 R (approximately 10-3 C x kg-1). The local dose dependence of the eyes was confirmed theoretically by drawing up a computer programme, and was related to the method used by the EMI scanner. (orig.)

  5. The feasibility of axial and coronal combined imaging using multi-detector row computed tomography for the diagnosis and treatment of a primary spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Kim Do

    2011-05-01

    Full Text Available Abstract Background The preoperative detection of emphysema like changes (ELCs is necessary for the successful treatment of pneumothorax. High resolution computed tomography (HRCT has been used for the preoperative detection of ELCs. However, the traditional HRCT method uses only the axial view, which is perpendicular to the distribution of ELCs. This is not an ideal diagnostic method for the evaluation of ELCs. Methods Forty-eight patients with pneumothorax had multi-detector computed tomography (MDCT reconstruction using the coronal view. ELCs were evaluated in the axial and coronal view by a radiologist. A surgeon performed intra-operative examinations of the ELCs. The sensitivity of the different views was compared. Results The detection sensitivity was 74.4% (70/94 for the axial view and 91.5% (86/94 for the axial-coronal combined view. The intra-operative detection rate was 95.7% (90/94. The preoperative detection of ELCs on the axial-coronal combined view was significantly higher than on the conventional axial view alone (p Conclusions Evaluation of ELCs on the axial and coronal combined HRCT improved the sensitivity of preoperative detection of ELCs compared to the conventional single axial HRCT. This increased sensitivity will help decrease the recurrence with VATS.

  6. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    Energy Technology Data Exchange (ETDEWEB)

    Dugas, Alexandre; Therasse, Eric; Kauffmann, Claude; Tang, An [University of Montreal, Department of Radiology, Centre Hospitalier de l' Universite de Montreal (CHUM) and CHUM Research Center (CRCHUM) (Canada); Elkouri, Stephane [University of Montreal, Department of Surgery, Centre Hospitalier de l' Universite de Montreal (CHUM) (Canada); Nozza, Anna [Institut de Cardiologie de Montreal, Montreal Heart Institute Coordinating Centre (Canada); Giroux, Marie-France; Oliva, Vincent L.; Soulez, Gilles, E-mail: gilles.soulez.chum@ssss.gouv.qc.ca [University of Montreal, Department of Radiology, Centre Hospitalier de l' Universite de Montreal (CHUM) and CHUM Research Center (CRCHUM) (Canada)

    2012-08-15

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001-0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662-0.780) and single-plane MPR images (0.772-0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

  7. Determination of the antetorsional angle at the femur via axial computer tomography

    International Nuclear Information System (INIS)

    The antetorsional angle was determined in several patient as well as in an isolated femoral bone by means of computer tomography. A comparison with Rippsteins method shows good correlation, taking different definitions of the antetorsional angle into consideration. Due to a mathematical correction method, the CT determination method is independent of the positioning of the patient. (orig.) 891 MG/orig. 892 MB

  8. Positioning study of cervical vertebra pedicle axial line projective point by computed tomography image reconstruction

    Institute of Scientific and Technical Information of China (English)

    ZHANG Pei-xun; XUE Feng; ZHANG Dian-ying; FU Zhong-guo; HAN Na; KOU Yu-hui; JIANG Bao-guo

    2012-01-01

    Background Safe placement of the screws is a critical aspect of trans-pedicle internal fixation,and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is available.The aim of this study was to measure the dimensions of cervical vertebrae C3 to C7 and provide screw length,screw diameter and tilt angle for clinical cervical vertebra trans-pedicle internal fixation.Methods Thirty Chinese men and women underwent high-speed spiral computed tomography measurements to obtain data for C3 to C7,and the morphology of the cervical vertebra pedicles was reconstructed.Results Reconstructed computer tomography image data revealed that:(1) pedicle sponge width increased incrementally from C3 to C7,(2) pedicle depth was similar for C3 to C7,(3) pedicle angle decreased incrementally from 47.20° to 33.76° for C3 to C7,and (4) pedicle point to midline distance was similar for C3 to C7.There were no statistical differences in morphological data between the right and the left side.Men had statistically larger values than women for all morphological parameters.Conclusions Reconstructed computed tomography images can provide useful data for clinical cervical vertebra trans-pedicle internal fixation.The individual measurement of cervical vertebra pedicles is recommended for safe placement of trans-vertebra pedicle screws.

  9. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

    International Nuclear Information System (INIS)

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm−1, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful

  10. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, P., E-mail: peter.andersson@physics.uu.se; Andersson-Sunden, E.; Sjöstrand, H.; Jacobsson-Svärd, S. [Department of Physics and Astronomy, Division of Applied Nuclear Physics, Uppsala University, Lägerhyddsgatan 1, 751 20 Uppsala (Sweden)

    2014-08-01

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful

  11. Axial resolution and the value of interpolating scan in multislice positron computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Senda, M.; Yonekura, Y.; Tamaki, N.; Tanaka, Y.; Komori, M.; Minato, K.; Torizuka, K.

    1985-05-01

    The authors have calculated the aperture function of a positron computed tomograph (PCT) with computer simulation and evaluated both theoretically and experimentally the axial resolution of a multislice PCT, Positologica III, which has 7 slices at the interval of 16mm. The axial point spread function (PSF) was approximately a triangle at or near the center of the field and the sensitivity for the slice decreased significantly as the source moved away off the image plane. Accordingly there are low sensitivity areas between an in-plane and the adjacent cross-plane. In experiments using a myocardial phantom, a small myocardial defect of 1cm diameter could not be detected when dropped into the gap between slices, although the machine had sufficiently high resolution to deliniate it if it was on the image plane. When long-axis images of the ''myocardium'' were reconstructed three-dimensionally from the images obtained in single object position, the ''inferior wall'' dropped into the gap and disappeared. In clinical myocardial scan with N-13 labeled ammonia in a normal volunteer, a false positive defect appeared in the inferior wall. However, when the object is slided half the slice interval to perform the ''interpolating'' scan and the two sets of images were interlaced with each other, no artifacts appeared. These results have suggested that the invisible regions between slices may be clinically significant if the object is thin enough in z-axis. In order to fill up the gaps between slices, it is valuable to perform the interpolating scan.

  12. Compton scatter axial tomography with x-rays: SCAT-CAT.

    Science.gov (United States)

    Brateman, L; Jacobs, A M; Fitzgerald, L T

    1984-11-01

    A method of extracting information from the backscattered field produced in parallel beam x-ray computed tomography (CT) is presented. A calculational model to predict the backscattered field based on Compton scattering is described, and the model is verified by measurements of simple phantoms. The phantoms tested--cylinders of polymethylmethacrylate (PMM) with air gaps and aluminium rods placed internally--are irradiated on a scanning assembly, built to simulate a first generation CT scanner with a transmission and a scatter detector (the SCAT-CAT). Data from the transmission detector are reconstructed by traditional CT methods to provide a transmission image; it is the data from the backscatter detector which are analysed in this study. After verification of the model for the scattered field calculations, a method of extracting information from the scattered field is developed, based on ratios of scatter signals from non-uniform to uniform phantoms. This method is demonstrated for predicted data of a simulated phantom and for measured data of the same and two additional phantoms. The method is very sensitive to air gaps in the phantoms because of the relative electron density of air with respect to PMM; it is not as sensitive to aluminium rods for the same reason. Various methods of applying the scattered field information to produce an image representing a simulated phantom are considered, and a preferred method is chosen to reconstruct scattered field data into an image for the three phantoms studied. PMID:6505017

  13. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    Directory of Open Access Journals (Sweden)

    Akinobu Watanabe

    Full Text Available Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT imaging. Complementary examination of external and internal osteology reveals (1 highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2 anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3 apneumatic sacral vertebrae; and (4 a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  14. Ultrastructural evidence of the excretory function in the asteroid axial organ (Asteroidea, Echinodermata).

    Science.gov (United States)

    Ezhova, O V; Egorova, E A; Malakhov, V V

    2016-05-01

    The ultrastructure of the axial organ of Asterias amurensis has been studied The organ is a network of canals of the axial coelom separated by haemocoelic spaces. The axial coelom is lined with two types of monociliary cells: podocytes and musculo-epithelial cells. Podocytes form numerous basal processes adjacent to the basal lamina on the coelomic side. Musculo-epithelial cells form processes running along the basal lamina. Some bundles of these processes wrapped in the basal lamina pass through haemocoelic spaces between neighboring coelomic canals. It is hypothesized that the axial organ serves for filtration of fluid from haemocoelic spaces into the axial coelom cavity, from which urine is excreted through the madreporite to the exterior. PMID:27411825

  15. Are Hox genes ancestrally involved in axial patterning? Evidence from the hydrozoan Clytia hemisphaerica (Cnidaria.

    Directory of Open Access Journals (Sweden)

    Roxane Chiori

    Full Text Available BACKGROUND: The early evolution and diversification of Hox-related genes in eumetazoans has been the subject of conflicting hypotheses concerning the evolutionary conservation of their role in axial patterning and the pre-bilaterian origin of the Hox and ParaHox clusters. The diversification of Hox/ParaHox genes clearly predates the origin of bilaterians. However, the existence of a "Hox code" predating the cnidarian-bilaterian ancestor and supporting the deep homology of axes is more controversial. This assumption was mainly based on the interpretation of Hox expression data from the sea anemone, but growing evidence from other cnidarian taxa puts into question this hypothesis. METHODOLOGY/PRINCIPAL FINDINGS: Hox, ParaHox and Hox-related genes have been investigated here by phylogenetic analysis and in situ hybridisation in Clytia hemisphaerica, an hydrozoan species with medusa and polyp stages alternating in the life cycle. Our phylogenetic analyses do not support an origin of ParaHox and Hox genes by duplication of an ancestral ProtoHox cluster, and reveal a diversification of the cnidarian HOX9-14 genes into three groups called A, B, C. Among the 7 examined genes, only those belonging to the HOX9-14 and the CDX groups exhibit a restricted expression along the oral-aboral axis during development and in the planula larva, while the others are expressed in very specialised areas at the medusa stage. CONCLUSIONS/SIGNIFICANCE: Cross species comparison reveals a strong variability of gene expression along the oral-aboral axis and during the life cycle among cnidarian lineages. The most parsimonious interpretation is that the Hox code, collinearity and conservative role along the antero-posterior axis are bilaterian innovations.

  16. Diagnostic Sensitivity of Multidetector-Row Spiral Computed Tomography Angiography in the Evaluation of Type-II Endoleaks and their Source: Comparison between Axial Scans and Reformatting Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saba, L.; Pascalis, L.; Montisci, R.; Sanfilippo, R.; Mallarini, G. (Depts. of Radiology and Vascular Surgery, Azienda Ospedaliero-Universitaria di Cagliari, Polo di Monserrato, Monserrato, Cagliari (Italy))

    2008-07-15

    Background: After endovascular stent-graft placement, several complications may occur. Retrograde filling of the aneurysm (type-II endoleak) is the most common. Purpose: To evaluate the accuracy, image quality, and interobserver agreement of multidetector-row spiral computed tomography angiography (MDCTA) in the diagnosis of type-II endoleak, by using various types of reformatting techniques in comparison to regular axial images. Material and Methods: Twenty-four patients who had had endovascular repair of an infrarenal abdominal aortic aneurysm with stent graft were retrospectively studied. In 12 of 24 patients, a type-II endoleak was found. CT scans were obtained after intravenous administration of 130 ml of nonionic contrast material using a 4-6-ml/s flow rate. All patients were investigated with axial scans, multiplanar reconstruction (MPR), maximum intensity projection (MIP), shaded-surface display (SSD), and volume-rendering (VR) techniques. For each patient and for each reconstruction method, the image quality of the scans was scored as 0 for bad quality, 1 for poor quality, 2 for good quality, and 3 for excellent quality images. Two radiologists reviewed the CT images independently. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each reconstruction method, with the axial images as the reference method. Interobserver agreement and kappa value were also recorded. Results: MPR showed the highest sensitivity (83% and 67% for observers 1 and 2, respectively), PPV (91% and 80% for observers 1 and 2, respectively), and NPV (85% and 71% for observers 1 and 2, respectively), whereas VR showed the highest specificity (92% for both observer 1 and 2). Conclusion: Reformatting techniques provide good-quality images; nevertheless, their efficacy in the study of type-II endoleak was found to be suboptimal in comparison to regular axial images. The MPR technique is probably the best choice in conjunction

  17. Iterative Reconstruction of Computed Axial Tomography images based on GPUs; Reconstruccion Iterativa de Imagenes TAC basada en GPUs

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, V.; Florez, L. A.; Mayo, P.; Rodenas, F.; Verdu, G.

    2013-07-01

    Although widely used in nuclear medicine (gamma-cameras, SPECT-single photon emission computed tomography, positron emission tomography, PET), the iterative image reconstruction is not widespread in Computed tomography (CT). The biggest reason for this is that the data set required in TAC is much higher than in nuclear medicine and iterative reconstruction is computationally very intensive. The graphics processing units (GPUs) provide the possibility to reduce the high computational cost of rebuilding in an effective way. The objective of this work is to develop image reconstruction algorithm based on GPUs.

  18. Limitaciones de la tomografia axial computada en la localizacion de quistes hidatidicos abdominales en pacientes con confirmacion inmunodiagnostica Limitations of computerized axial tomography in the localization of abdominal hydatid cysts in patients with immunodiagnostic confirmation

    Directory of Open Access Journals (Sweden)

    E. A. Guarnera

    1984-12-01

    Full Text Available Se describe el aporte de la prueba de doble disfusión arco 5 (DD5 al diagnóstico de la hidatidosis en dos pacientes con operaciones previas. En una de ellas, asintomática, la reacción positiva a los cinco años de su última intervención quirúrgica por hidatidosis, permitió diagnosticar la presencia de quistes cuya localización abdominal fue establecida por la tomografía axial computada (TAC. En el otro caso, sintomático, aunque operado de hidatidosis nueve años antes, la positividad a la DD5 confirmó la etiología de la enfermedad que se había sospechado por centellografía, TAC y su historia clínica. En ambos casos, sin embargo, se hallaron en el acto quirúrgico otros quistes abdominales cuyas imágenes no habían sido reveladas en los estudios a los que se las había sometido.The contribution of the arc 5 double diffusion test (DD5 to the diagnosis of hydatidosis in two patients with previous surgery for this parasitic infection is described. In one of the patients, who was asymptomatic, the diagnosis was established on the basis of a positive DD5 reaction five years after her last surgical intervention. The abdominal location of cysts was revealed by computerized axial tomography (CAT. The other patient had been operated on for hydatidosis nine years earlier and showed symptoms. Positivity to the DD5 test confirmed the etiology of the disease, which had been suspected on the basis of her clinical history and the findings of scintillographic and CAT studies. In both cases, however, other abdominal cysts were found at surgery whose images had not been revealed in the previous studies.

  19. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  20. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  1. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nizic, Dinko [Zagreb University Hospital Center, Clinical Institute of Diagnostic and Interventional Radiology, Zagreb (Croatia)

    2012-09-15

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  2. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E. (National Institute of Aging, Baltimore, MD (USA))

    1990-11-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas.

  3. Sensitivity of computer assisted radionuclide angiography in transient ischemic attack and prolonged reversible ischemic neurological deficit. Comparison with findings in radiographic angiography and transmission computerized axial tomography

    Energy Technology Data Exchange (ETDEWEB)

    Buell, U.; Scheid, K.F.; Lanksch, W.; Kleinhans, E.; Ulbert, V.; Reger, U.; Rath, M.; Moser, E.A.

    Computer assisted radionuclide angiography (CARNA) with 99mTc-DTPA was employed to study 143 patients with transient ischemic attacks (TIA) and 79 patients with prolonged reversible ischemic neurologic deficit (PRIND). The results of CARNA were compared with findings from radiographic angiography (RGA) in 173 patients and with findings in transmission computerized axial tomography (T-CAT) in 154 patients. In patients with TIA, CARNA showed a hemispherical perfusion deficit in 74.8%, and with PRIND 87.3%. This deficit, determined as the relative difference between the involved and the non-involved hemisphere, was significantly (p less than 0.0025) greater in PRIND (minus 23%) than in TIA (minus 17%). Sensitivity of CARNA was independent of the interval from ictus to examination for more than 4 months. RGA in TIA revealed true positives in 82.0%, in PRIND it was 89.5%. T-CAT was positive in TIA in only 16.8% but in PRIND it was 64.4%. Combined sensitivities in TIA (92.4%) and in PRIND (94.0%) were highest with the combination of CARNA and RGA. However, in PRIND the combination of non-invasive methods (CARNA and T-CAT) revealed 93.2% positive findings. Combinations of these evaluation methods may be used to detect cerebrovascular disease in patients with such dysfunction.

  4. Correlação entre hipótese diagnóstica e laudo de tomografia axial computadorizada craniana Correlation between diagnostic hypothesis and result of cranial computed axial tomography

    Directory of Open Access Journals (Sweden)

    Edison Matos Nóvak

    2001-09-01

    Full Text Available Para avaliar a utilização da tomografia axial computadorizada craniana (TC em nosso meio, analisamos as solicitações de 367 exames consecutivos no período compreendido entre 07/1995 e 07/1996. Houve ampla variação da faixa etária, com média de 31,7 ± 22,9 anos. As especialidades que mais solicitaram o exame foram: Neurologia (36,2%, Pronto Atendimento (17,4%, Neuropediatria (16,9% e Clínica Médica (5,9%. As indicações mais frequentes para o exame foram: convulsão (30%, cefaléia (26,2%, déficit motor (20,2% e redução do nível de consciência (16,9%. As "hipóteses" aventadas com maior frequência foram: afastar lesão estrutural (9,0%, acidente vascular não discriminado (8,2% e neurocisticercose (8,2%. O laudo da TC foi normal em 50,4% dos exames. Os laudos anormais mais frequentes foram: hidrocefalia (5,4%, acidente vascular isquêmico (5,4% e neoplasia (3,5%. As maiores taxas de achados normais foram encontradas nas "hipóteses" de cefaléia (94,4%, convulsão (71,4% e afastar lesão estrutural (66,7%. Os maiores índices de acerto entre hipótese e laudo foram encontrados nas situações de "afastar lesões estruturais" (66,7%, hidrocefalia (50%, acidente vascular cerebral isquêmico (50% e hematoma (50%. Concluimos que a utilização de um recurso auxiliar de diagnóstico como a TC cumpre melhor ainda a sua função se o requisitante do exame preencher com clareza e detalhamento o pedido do exame.The use of computed axial tomography (CT in the investigation of neurologic disorders is attractive for his disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 ± 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36

  5. Study of the relationship and importance of clinical semiology, axial computed tomography and electroneuromyography in lumbar radioculopathies Estudo da relação e da importância entre a semiologia clínica, tomografia axial computadorizada e eletroneuromiografia nas radiculopatias lombares

    Directory of Open Access Journals (Sweden)

    Emílio Cezar Mamede Murade

    2002-12-01

    Full Text Available The authors evaluated forty-three patients with clinical suspect of lumbar radiculopathy caused by disk hernia, concerning to clinical semiology, computed tomography and electromyography were studied and their correlations. The clinical semiology was altered in 100,0% of the patients, the computed tomography in 90,7% and the electromyography in 88,7%. The correlation among the three exams didn´t show any prevalency among any of the possible associations. The authors emphasize the importance of clinical semiology, computed tomography and electromyography for a more accurate diagnosis of lumbar radiculopathy following by disk hernia.Os autores estudaram 43 pacientes com suspeita clínica de radiculopatia lombar, causada por hérnia de disco, relacionando os achados da semiologia clínica, tomografia axial computadorizada e eletroneuromiografia, entre si. A semiologia clínica estava alterada em 100,0% dos pacientes, a tomografia axial computadorizada em 90,7% e a eletroneuromiografia em 88,7%. A correlação entre os três exames não mostrou prevalência entre nenhuma associação. Os autores enfatizam a importância da semiologia clínica, tomografia axial computadorizada e eletroneuromiografia para maior exatidão diagnóstica das radiculopatias lombares por hérnia de disco.

  6. Evidence for iron and sulfur enrichments in hydrothermal plumes at Axial Volcano following the January-February 1998 eruption

    Science.gov (United States)

    Feely, Richard A.; Baker, Edward T.; Lebon, Geoff T.; Gendron, James F.; Resing, Joseph A.; Cowen, James P.

    In response to 12 days of seismic activity at Axial Volcano, Juan de Fuca Ridge in January-February 1998, the NSF/NOAA-sponsored Axial Response Team conducted three response cruises in February, August, and August/September to map and sample hydrothermal plumes over the region. Vertical profiles of particulate Fe and S over the eruption site show high concentrations from about 1400 m to the bottom. Chemical and scanning electron microscope analysis of the February plume samples revealed anhydrite, Fe-ferrihydrites, elemental sulfur, and angular glassy basalt shards up to 190 µm in the longest dimension. Many of these shards had halite coatings, which is consistent with subseafloor basalt seawater reactions at temperatures >450°C at 1500 m depth. In August and September cruises the basalt shards were no longer present in the hydrothermal plumes. Instead, the plumes were predominantly composed of Fe-ferrihydrites, elemental sulfur, and sulfur filaments. A unique feature of this data set is the high concentrations of elemental sulfur in the lower 60 m of the water column. The sulfur results are suggestive of a significant enrichment of the bacterial biomass in the water column over the eruption site with time. Within the Axial caldera, approximately 10-20% of the total sulfur is present as sulfur filaments. These post-eruption particle compositional changes have strong similarities to the results from the 1993 CoAxial eruption on the Juan de Fuca Ridge.

  7. Limitaciones de la tomografia axial computada en la localizacion de quistes hidatidicos abdominales en pacientes con confirmacion inmunodiagnostica Limitations of computerized axial tomography in the localization of abdominal hydatid cysts in patients with immunodiagnostic confirmation

    OpenAIRE

    Guarnera, E A; V. M. Varela-Díaz

    1984-01-01

    Se describe el aporte de la prueba de doble disfusión arco 5 (DD5) al diagnóstico de la hidatidosis en dos pacientes con operaciones previas. En una de ellas, asintomática, la reacción positiva a los cinco años de su última intervención quirúrgica por hidatidosis, permitió diagnosticar la presencia de quistes cuya localización abdominal fue establecida por la tomografía axial computada (TAC). En el otro caso, sintomático, aunque operado de hidatidosis nueve años antes, la positividad a la DD5...

  8. Correlação entre hipótese diagnóstica e laudo de tomografia axial computadorizada craniana Correlation between diagnostic hypothesis and result of cranial computed axial tomography

    OpenAIRE

    Edison Matos Nóvak; Fábio Terabe; André Luís Nasimoto; Paulo Henrique Migliari de Carvalho; Ariane Desirée Loper; Fabiana Schenato Büchele; Júlio César Nogara

    2001-01-01

    Para avaliar a utilização da tomografia axial computadorizada craniana (TC) em nosso meio, analisamos as solicitações de 367 exames consecutivos no período compreendido entre 07/1995 e 07/1996. Houve ampla variação da faixa etária, com média de 31,7 ± 22,9 anos. As especialidades que mais solicitaram o exame foram: Neurologia (36,2%), Pronto Atendimento (17,4%), Neuropediatria (16,9%) e Clínica Médica (5,9%). As indicações mais frequentes para o exame foram: convulsão (30%), cefaléia (26,2%),...

  9. Ultrastructure and potential sub-seafloor evidence of bacteriogenic iron oxides from Axial Volcano, Juan de Fuca Ridge, north-east Pacific Ocean.

    Science.gov (United States)

    Kennedy, C B; Scott, S D; Ferris, F G

    2003-03-01

    Iron oxides from the caldera of Axial Volcano, a site of hydrothermal vent activity along the Juan de Fuca Ridge, were found to consist predominantly of microbial structures in hydrated whole mounts examined using an environmental scanning electron microscope. Novel observations were made of the iron oxides revealing the spatial relationships of the bacteria within to be more consistent with microbial mats than mineral precipitates. The bacterial structures are attributed to the sheaths of Leptothrix ochracea, the stalks of Gallionella ferruginea, and the filaments of a novel iron oxidizing PV-1 strain, based on the distinctive morphological characteristics of these three bacteria. Energy dispersive X-ray spectroscopy revealed the presence and distribution of Fe, Si, and Cl on the bacterial sheaths, stalks and filaments. The iron oxides were identified by X-ray diffraction to be two-line ferrihydrite, a poorly ordered iron oxyhydroxide. Adsorption of Si in particular to two-line ferrihydrite likely contributes to its stability on the seafloor, and might also be a preservation mechanism creating microfossils of the bacterial structures encrusted with ferrihydrite. Presumptive evidence of the sub-seafloor presence of L. ochracea, G. ferruginea and PV-1 at Axial Volcano was obtained from the presence of these bacteria on a trap that had been placed within an active vent, and also in a vent fluid sample. If indeed these bacteria are present in the sub-seafloor, it may be an indication that the surface expression of iron oxide deposits at Axial Volcano is minimal in comparison to what exists beneath the seafloor.

  10. Computed tomography evidence of dental restoration as aetiological factor for maxillary sinusitis.

    Science.gov (United States)

    Connor, S E; Chavda, S V; Pahor, A L

    2000-07-01

    Maxillary sinusitis due to dental causes is usually secondary to periodontal disease or periapical infection and is commonly associated with mucosal thickening of the floor of the maxillary antrum. Computed tomography (CT) is currently the modality of choice for evaluating the extent of disease and any predisposing factors in patients with symptoms of chronic maxillary sinusitis, but it is unable to diagnose dental disease reliably. The presence of restorative dentistry is, however, easily seen at CT and is associated with both periapical and periodontal disease. We aimed to determine whether its presence at CT may predispose to maxillary sinusitis, and in particular to focal mucosal thickening of the sinus floor characteristic of dental origin. Three hundred and thirty maxillary sinus CT images in 165 patients were reviewed for the presence of restorative dentistry in the adjacent teeth, focal maxillary sinus floor mucosal thickening, any maxillary sinus disease (including complete opacification, air fluid levels, diffuse mucosal thickening, focal mucosal thickening) and evidence of a rhinogenic aetiology (osteomeatal complex pathology, mucosal thickening in other sinuses). One hundred and ninety two sinuses adjacent to restorative dentistry and 178 sinuses not adjacent to restorative dentistry were analysed. Focal floor thickening both with, and without, evidence of a rhinogenic aetiology, was significantly more common adjacent to restorative dentistry. Maxillary sinus disease overall was no more common adjacent to restorative dentistry. This work demonstrated that the presence of restorative dentistry predisposes to focal mucosal thickening in the floor of the maxillary sinus and its presence should prompt clinical and radiographical assessment to exclude dental disease as a source of chronic maxillary sinusitis.

  11. Hybrid averaging offers high-flow contrast by cost apportionment among imaging time, axial, and lateral resolution in optical coherence tomography angiography.

    Science.gov (United States)

    Li, Peng; Cheng, Yuxuan; Li, Pei; Zhou, Liping; Ding, Zhihua; Ni, Yang; Pan, Cong

    2016-09-01

    The current temporal, wavelength, angular, and spatial averaging approaches trade imaging time and resolution for multiple independent measurements that improve the flow contrast in optical coherence tomography angiography (OCTA). We find that these averaging approaches are equivalent in principle, offering almost the same flow contrast enhancement as the number of averages increases. Based on this finding, we propose a hybrid averaging strategy for contrast enhancement by cost apportionment. We demonstrate that, compared with any individual approach, the hybrid averaging is able to offer a desired flow contrast without severe degradation of imaging time and resolution. Making use of the extended range of a VCSEL-based swept-source OCT, an angular averaging approach by path length encoding is also demonstrated for flow contrast enhancement. PMID:27607943

  12. Axial skeletal CT densitometry

    International Nuclear Information System (INIS)

    Since the discovery of the Roentgen ray a precise and accurate assessment of bone mineral content has been a challenge to many investigators. A number of methods have been developed but no one satisfied. Considering its technical possibilities computed tomography is very promising in determination of bone mineral content (BMC). The new modality enables BMC estimations in the axial skeletal trabecular bone. CT densitometry can be performed on a normal commercially available third generation whole body CT scanner. No dedicated device in a special clinical set-up is necessary. In this study 106 patients, most of them clinically suspected of osteoporosis, were examined. The new method CT densitometry has been evaluated. The results have been correlated to alternative BMC determination methods. (Auth.)

  13. Evidence of shallow gas in the Queen Charlotte Basin from waveform tomography of seismic reflection data

    Energy Technology Data Exchange (ETDEWEB)

    Takam Takougang, Eric M.; Calvert, Andrew J. [Simon Fraser University (Canada)], email: eta9@sfu.ca

    2011-07-01

    The Geological Survey of Canada (GSC) collected eight seismic reflection lines in 1988 across the Queen Charlotte sedimentary basin of western Canada, which is the largest tertiary basin on the west coast. This work furthers the study of the upper part of the basin by using quantitative imaging of its structure through application of 2-D waveform tomography to the limited offset seismic reflection data. With the help of waveform tomography, seismic reflection data has allowed the identification of pockmark structures and pipe-like gas chimney in the recovered velocity and attenuation models. Overall, there is an excellent match between field data and predicted data. and a good match between the sonic log and a 1-D velocity function derived from the 2-D velocity model. This shows that specific preconditioning of the data and a good inversion strategy make it possible to use waveform tomography of relatively short offset reflection data for the imaging of shallow geological features.

  14. Origin of the Changbai intraplate volcanism in Northeast China:Evidence from seismic tomography

    Institute of Scientific and Technical Information of China (English)

    ZHAO Dapeng; LEI Jianshe; TANG Rongyu

    2004-01-01

    Seismic images of the mantle beneath the active Changbai intraplate volcano in Northeast China determined by teleseismic travel time tomography are presented. The data are measured at a new seismic network consisting of 19 portable stations and 3 permanent stations. The results show a columnar low-velocity (-3 %) anomaly extending to 400 km depth under the Changbai volcano. High velocity anomalies are visible in the mantle transition zone, and deep earthquakes occur at depths of 500-600 km under the region,suggesting that the subducting Pacific slab is stagnant in the transition zone, as imaged clearly also by global tomography.These results suggest that the Changbai intraplate volcano is not a hotspot like Hawaii but a kind of back-arc volcano related to the upwelling of hot asthenospheric materials associated with the deep subduction and stagnancy of the Pacific slab under northeast Asia.

  15. Evidence of magma activation beneath the Lunayyir basaltic field (Saudi Arabia from attenuation tomography

    Directory of Open Access Journals (Sweden)

    I. Koulakov

    2014-06-01

    Full Text Available We present a seismic attenuation model for the crust beneath the Cenozoic basaltic field of Lunayyir (western Saudi Arabia, where a strong seismic swarm occurred in 2009. The tomography inversion uses the envelope shape of the S wave seismograms from over 300 strong events (M > 3.5. The resulting attenuation structures appear to be consistent with the distribution of seismic velocities. The obtained 3-D attenuation model distinguishes the low-attenuation zones down to 5 km depth corresponding to the rigid basaltic cover. At greater depths, we detect a high-attenuation anomaly coinciding with the main seismicity cluster. We propose that this zone corresponds to the upper part of the conduit area ascending from deeper magma sources. According to the distributions of local events, fluids and melts from this conduit appear to reach a depth of ~2 km, but were not able to reach the surface and cause the eruption in 2009.

  16. Contrasting Subduction Modes with Slab Tearing beneath Eastern Himalaya: Evidence from Teleseismic P-wave Tomography

    Science.gov (United States)

    Peng, M.; Jiang, M.; Li, Z. H.; Xu, Z.; Chen, Y.; Chan, W. W. W.; Wang, Y.; Yu, C.; Lei, J.

    2014-12-01

    On the eastern margin of the Himalayan orogenic belt, the rapid uplift of the Namche Barwa metamorphic terrane and the significant bending of the Yarlung Zangbo suture zone occur. However, the formation mechanism and dynamics of the Eastern Himalayan Syntaxis is still debated. In order to better understand the deep structures beneath eastern Himalaya, we further deployed 35 broadband seismic stations (2010-2013) around the Namche Barwa Mountain, which is integrated with the existing Lehigh data sets of 45 stations (2003-2004). We totally selected 18,979 high-quality P-wave arrival times from 2,140 teleseismic events to image P-wave teleseismic tomography. The results demonstrate complex deep structures and significantly different subduction modes in the eastern Himalaya. In contrast to the steep subduction of the Indian lithosphere beneath the Eastern Himalayan Syntaxis, the Indian slab flatly subducted in the west, which might extend close to the Bangong-Nujiang Suture and then steeply sink and bend over. The contrasting subduction model results in the tearing and fragmentation of the Indian lithosphere in the transition zone between the flat and steep subduction. Consequently, the upwelling of hot asthenospheric mantle may occur through the slab tear window, which might further lead to the rapid uplift of Namche Barwa and the formation of the Eastern Himalayan Syntaxis. The lateral variation in subduction mode and slab tearing induced asthenospheric mantle upwelling is similar to that observed in the Hellenide and Anatolide domains of the Tethyan orogen.

  17. Multislice computed tomography coronary angiography

    OpenAIRE

    Cademartiri, Filippo

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield of EMI Laboratories, England, and independently by South Mrican born physicist Allan Cormack of Tufts University, Massachusetts.1 • 2 Hounsfield was later awarded the Nobel Peace Prize and honoured with K...

  18. Positron Emission Tomography (PET) in the oncologic clinical practice

    International Nuclear Information System (INIS)

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  19. Cryoelectron tomography of HIV-1 envelope spikes: further evidence for tripod-like legs.

    Directory of Open Access Journals (Sweden)

    Ping Zhu

    2008-11-01

    Full Text Available A detailed understanding of the morphology of the HIV-1 envelope (Env spike is key to understanding viral pathogenesis and for informed vaccine design. We have previously presented a cryoelectron microscopic tomogram (cryoET of the Env spikes on SIV virions. Several structural features were noted in the gp120 head and gp41 stalk regions. Perhaps most notable was the presence of three splayed legs projecting obliquely from the base of the spike head toward the viral membrane. Subsequently, a second 3D image of SIV spikes, also obtained by cryoET, was published by another group which featured a compact vertical stalk. We now report the cryoET analysis of HIV-1 virion-associated Env spikes using enhanced analytical cryoET procedures. More than 2,000 Env spike volumes were initially selected, aligned, and sorted into structural classes using algorithms that compensate for the "missing wedge" and do not impose any symmetry. The results show varying morphologies between structural classes: some classes showed trimers in the head domains; nearly all showed two or three legs, though unambiguous three-fold symmetry was not observed either in the heads or the legs. Subsequently, clearer evidence of trimeric head domains and three splayed legs emerged when head and leg volumes were independently aligned and classified. These data show that HIV-1, like SIV, also displays the tripod-like leg configuration, and, unexpectedly, shows considerable gp41 leg flexibility/heteromorphology. The tripod-like model for gp41 is consistent with, and helps explain, many of the unique biophysical and immunological features of this region.

  20. Subduction of continental lithosphere in the Banda Sea region: Combining evidence from full waveform tomography and isotope ratios

    Science.gov (United States)

    Fichtner, Andreas; De Wit, Maarten; van Bergen, Manfred

    2010-09-01

    We provide new insight into the subduction of old continental lithosphere to depths of more than 100 km beneath the Banda arc, based on a spatial correlation of full waveform tomographic images of its lithosphere with He, Pb, Nd and Sr isotope signatures in its arc volcanics. The thickness of the subducted lithosphere of around 200 km coincides with the thickness of Precambrian lithosphere as inferred from surface wave tomography. While the deep subduction of continental material in continent-continent collisions is widely recognised, the analogue process in the arc-continent collision of the Banda region is currently unique. The integrated data suggest that the late Jurassic ocean lithosphere north of the North Australian craton was capable of entraining large volumes of continental lithosphere. The Banda arc example demonstrates that continental lithosphere in arc-continent collisions is not generally preserved, thus increasing the complexity of tectonic reconstructions. In the particular case of Timor, the tomographic images indicate that this island is not located directly above the northern margin of the North Australian craton, and that decoupled oceanic lithosphere must be located at a considerable distance north of Timor, possibly as far north as the northern margin of the volcanically extinct arc sector. The tomographic images combined with isotope data suggest that subduction of the continental lithosphere did not lead to the delamination of its complete crust. A plausible explanation involves delamination within the continental crust, separating upper from lower crustal units. This interpretation is consistent with the existence of a massive accretionary complex on Timor island, with evidence from Pb isotope analysis for lower-crust involvement in arc volcanism; and with the approximate gravitational stability of the subducted lithosphere as inferred from the tomographic images. The subduction of continental lithosphere including crustal material beneath

  1. Axial Halbach Magnetic Bearings

    Science.gov (United States)

    Eichenberg, Dennis J.; Gallo, Christopher A.; Thompson, William K.

    2008-01-01

    Axial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly reliable noncontact bearings for future high-speed rotary machines that may be used in such applications as aircraft, industrial, and land-vehicle power systems and in some medical and scientific instrumentation systems. Axial Halbach magnetic bearings are passive in the sense that unlike most other magnetic bearings that have been developed in recent years, they effect stable magnetic levitation without need for complex active control.

  2. Axial static mixer

    Science.gov (United States)

    Sandrock, H.E.

    1982-05-06

    Static axial mixing apparatus includes a plurality of channels, forming flow paths of different dimensions. The axial mixer includes a flow adjusting device for adjustable selective control of flow resistance of various flow paths in order to provide substantially identical flows through the various channels, thereby reducing nonuniform coating of interior surfaces of the channels. The flow adjusting device may include diaphragm valves, and may further include a pressure regulating system therefor.

  3. Surface nanoscale axial photonics

    OpenAIRE

    Sumetsky, M.; Fini, J. M.

    2011-01-01

    Dense photonic integration promises to revolutionize optical computing and communications. However, efforts towards this goal face unacceptable attenuation of light caused by surface roughness in microscopic devices. Here we address this problem by introducing Surface Nanoscale Axial Photonics (SNAP). The SNAP platform is based on whispering gallery modes circulating around the optical fiber surface and undergoing slow axial propagation readily described by the one-dimensional Schr\\"odinger e...

  4. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  5. Modular functional organisation of the axial locomotor system in salamanders.

    Science.gov (United States)

    Cabelguen, Jean-Marie; Charrier, Vanessa; Mathou, Alexia

    2014-02-01

    Most investigations on tetrapod locomotion have been concerned with limb movements. However, there is compelling evidence that the axial musculoskeletal system contributes to important functions during locomotion. Adult salamanders offer a remarkable opportunity to examine these functions because these amphibians use axial undulations to propel themselves in both aquatic and terrestrial environments. In this article, we review the currently available biological data on axial functions during various locomotor modes in salamanders. We also present data showing the modular organisation of the neural networks that generate axial synergies during locomotion. The functional implication of this modular organisation is discussed.

  6. Computational, electrochemical, and spectroscopic studies of two mononuclear cobaloximes: the influence of an axial pyridine and solvent on the redox behaviour and evidence for pyridine coordination to cobalt(i) and cobalt(ii) metal centres.

    Science.gov (United States)

    Lawrence, Mark A W; Celestine, Michael J; Artis, Edward T; Joseph, Lorne S; Esquivel, Deisy L; Ledbetter, Abram J; Cropek, Donald M; Jarrett, William L; Bayse, Craig A; Brewer, Matthew I; Holder, Alvin A

    2016-06-21

    [Co(dmgBF2)2(H2O)2] (where dmgBF2 = difluoroboryldimethylglyoximato) was used to synthesize [Co(dmgBF2)2(H2O)(py)]·0.5(CH3)2CO (where py = pyridine) in acetone. The formulation of complex was confirmed by elemental analysis, high resolution MS, and various spectroscopic techniques. The complex [Co(dmgBF2)2(solv)(py)] (where solv = solvent) was readily formed in situ upon the addition of pyridine to complex . A spectrophotometric titration involving complex and pyridine proved the formation of such a species, with formation constants, log K = 5.5, 5.1, 5.0, 4.4, and 3.1 in 2-butanone, dichloromethane, acetone, 1,2-difluorobenzene/acetone (4 : 1, v/v), and acetonitrile, respectively, at 20 °C. In strongly coordinating solvents, such as acetonitrile, the lower magnitude of K along with cyclic voltammetry, NMR, and UV-visible spectroscopic measurements indicated extensive dissociation of the axial pyridine. In strongly coordinating solvents, [Co(dmgBF2)2(solv)(py)] can only be distinguished from [Co(dmgBF2)2(solv)2] upon addition of an excess of pyridine, however, in weakly coordinating solvents the distinctions were apparent without the need for excess pyridine. The coordination of pyridine to the cobalt(ii) centre diminished the peak current at the Epc value of the Co(I/0) redox couple, which was indicative of the relative position of the reaction equilibrium. Herein we report the first experimental and theoretical (59)Co NMR spectroscopic data for the formation of Co(i) species of reduced cobaloximes in the presence and absence of py (and its derivatives) in CD3CN. From spectroelectrochemical studies, it was found that pyridine coordination to a cobalt(i) metal centre is more favourable than coordination to a cobalt(ii) metal centre as evident by the larger formation constant, log K = 4.6 versus 3.1, respectively, in acetonitrile at 20 °C. The electrosynthesis of hydrogen by complexes and in various solvents demonstrated the dramatic effects of the axial

  7. On renormalization of axial anomaly

    International Nuclear Information System (INIS)

    It is shown that multiplicative renormalization of the axial singlet current results in renormalization of the axial anomaly in all orders of perturbation theory. It is a necessary condition for the Adler - Bardeen theorem being valid. 10 refs.; 2 figs

  8. Grapevine petioles are more sensitive to drought induced embolism than stems: evidence from in vivo MRI and microcomputed tomography observations of hydraulic vulnerability segmentation.

    Science.gov (United States)

    Hochberg, Uri; Albuquerque, Caetano; Rachmilevitch, Shimon; Cochard, Herve; David-Schwartz, Rakefet; Brodersen, Craig R; McElrone, Andrew; Windt, Carel W

    2016-09-01

    The 'hydraulic vulnerability segmentation' hypothesis predicts that expendable distal organs are more susceptible to water stress-induced embolism than the main stem of the plant. In the current work, we present the first in vivo visualization of this phenomenon. In two separate experiments, using magnetic resonance imaging or synchrotron-based microcomputed tomography, grapevines (Vitis vinifera) were dehydrated while simultaneously scanning the main stems and petioles for the occurrence of emboli at different xylem pressures (Ψx ). Magnetic resonance imaging revealed that 50% of the conductive xylem area of the petioles was embolized at a Ψx of -1.54 MPa, whereas the stems did not reach similar losses until -1.9 MPa. Microcomputed tomography confirmed these findings, showing that approximately half the vessels in the petioles were embolized at a Ψx of -1.6 MPa, whereas only few were embolized in the stems. Petioles were shown to be more resistant to water stress-induced embolism than previously measured with invasive hydraulic methods. The results provide the first direct evidence for the hydraulic vulnerability segmentation hypothesis and highlight its importance in grapevine responses to severe water stress. Additionally, these data suggest that air entry through the petiole into the stem is unlikely in grapevines during drought.

  9. Grapevine petioles are more sensitive to drought induced embolism than stems: evidence from in vivo MRI and microcomputed tomography observations of hydraulic vulnerability segmentation.

    Science.gov (United States)

    Hochberg, Uri; Albuquerque, Caetano; Rachmilevitch, Shimon; Cochard, Herve; David-Schwartz, Rakefet; Brodersen, Craig R; McElrone, Andrew; Windt, Carel W

    2016-09-01

    The 'hydraulic vulnerability segmentation' hypothesis predicts that expendable distal organs are more susceptible to water stress-induced embolism than the main stem of the plant. In the current work, we present the first in vivo visualization of this phenomenon. In two separate experiments, using magnetic resonance imaging or synchrotron-based microcomputed tomography, grapevines (Vitis vinifera) were dehydrated while simultaneously scanning the main stems and petioles for the occurrence of emboli at different xylem pressures (Ψx ). Magnetic resonance imaging revealed that 50% of the conductive xylem area of the petioles was embolized at a Ψx of -1.54 MPa, whereas the stems did not reach similar losses until -1.9 MPa. Microcomputed tomography confirmed these findings, showing that approximately half the vessels in the petioles were embolized at a Ψx of -1.6 MPa, whereas only few were embolized in the stems. Petioles were shown to be more resistant to water stress-induced embolism than previously measured with invasive hydraulic methods. The results provide the first direct evidence for the hydraulic vulnerability segmentation hypothesis and highlight its importance in grapevine responses to severe water stress. Additionally, these data suggest that air entry through the petiole into the stem is unlikely in grapevines during drought. PMID:26648337

  10. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  11. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  12. Evident?

    DEFF Research Database (Denmark)

    Plant, Peter

    2012-01-01

    Quality assurance and evidence in career guidance in Europe are often seen as self-evident approaches, but particular interests lie behind......Quality assurance and evidence in career guidance in Europe are often seen as self-evident approaches, but particular interests lie behind...

  13. Positron Emission Tomography (PET) in the oncologic clinical practice; Tomografia por Emision de Positrones (PET) en la practica clinica oncologica

    Energy Technology Data Exchange (ETDEWEB)

    Serna M, J.A.; Luviano, C.; Martinez V, D. [Hospital Angeles del Pedregal Mexico DF (Mexico); Maldonado S, A. [Centro PET Complutense, Madrid (Spain)

    2005-07-01

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  14. Influence of pore size distributions on decomposition of maize leaf residue: evidence from X-ray computed micro-tomography

    Science.gov (United States)

    Negassa, Wakene; Guber, Andrey; Kravchenko, Alexandra; Rivers, Mark

    2014-05-01

    Soil's potential to sequester carbon (C) depends not only on quality and quantity of organic inputs to soil but also on the residence time of the applied organic inputs within the soil. Soil pore structure is one of the main factors that influence residence time of soil organic matter by controlling gas exchange, soil moisture and microbial activities, thereby soil C sequestration capacity. Previous attempts to investigate the fate of organic inputs added to soil did not allow examining their decomposition in situ; the drawback that can now be remediated by application of X-ray computed micro-tomography (µ-CT). The non-destructive and non-invasive nature of µ-CT gives an opportunity to investigate the effect of soil pore size distributions on decomposition of plant residues at a new quantitative level. The objective of this study is to examine the influence of pore size distributions on the decomposition of plant residue added to soil. Samples with contrasting pore size distributions were created using aggregate fractions of five different sizes (soil samples. Dried pieces of maize leaves 2.5 mg in size (equivalent to 1.71 mg C g-1 soil) were added to half of the studied samples. Samples with and without maize leaves were incubated for 120 days. CO2 emission from the samples was measured at regular time intervals. In order to ensure that the observed differences are due to differences in pore structure and not due to differences in inherent properties of the studied aggregate fractions, we repeated the whole experiment using soil from the same aggregate size fractions but ground to soil size fractions of intact aggregates, and 40-50% in ground samples, respectively. The results of the incubation experiment demonstrated that, while greater C mineralization was observed in samples of all size fractions amended with leaf, the effect of leaf presence was most pronounced in the smaller aggregate fractions (0.05-0.1 mm and 0.05 mm) of intact aggregates. The results of

  15. Extra-axial brain tumors.

    Science.gov (United States)

    Rapalino, Otto; Smirniotopoulos, James G

    2016-01-01

    Extra-axial brain tumors are the most common adult intracranial neoplasms and encompass a broad spectrum of pathologic subtypes. Meningiomas are the most common extra-axial brain tumor (approximately one-third of all intracranial neoplasms) and typically present as slowly growing dural-based masses. Benign meningiomas are very common, and may occasionally be difficult to differentiate from more aggressive subtypes (i.e., atypical or malignant varieties) or other dural-based masses with more aggressive biologic behavior (e.g., hemangiopericytoma or dural-based metastases). Many neoplasms that typically affect the brain parenchyma (intra-axial), such as gliomas, may also present with primary or secondary extra-axial involvement. This chapter provides a general and concise overview of the common types of extra-axial tumors and their typical imaging features. PMID:27432671

  16. Atom probe tomography evidence for uniform incorporation of Bi across the growth front in GaAs1-xBix/GaAs superlattice

    Science.gov (United States)

    Chen, Weixin; Ronsheim, Paul A.; Wood, Adam W.; Forghani, Kamran; Guan, Yingxin; Kuech, Thomas F.; Babcock, Susan E.

    2016-07-01

    The three-dimensional distribution of Bi atoms in a GaAs1-xBix/GaAs superlattice grown by metalorganic vapor phase epitaxy (MOVPE) was studied using atom probe tomography (APT). The Bi distribution in the growth direction deduced from APT agreed quantitatively with the complex Bi concentration profile that was discovered using high-angle annular dark-field scanning transmission electron microscopy in a previous study. More importantly, APT revealed the Bi atom distribution in the growth planes at near atomic resolution. Bi nearest neighbor distribution and concentration frequency distribution analysis of the APT data indicated a statistically random distribution of Bi atoms in 1-2 nm thick layers oriented perpendicular to the growth direction. These results provide evidence that Bi is incorporated homogeneously across the growth front even when the concentration profile in the growth direction is complex. They also suggest that MOVPE growth conditions can promote uniform Bi distribution within GaAs1-xBix layers, opening a path for application of these materials in the optoelectronic devices for which they show much promise.

  17. Macular thickness measured by stratus optical coherence tomography in patients with diabetes type 2 and mild nonproliferative retinopathy without clinical evidence of macular edema.

    Science.gov (United States)

    Pires, Isabel; Santos, Ana Rita; Nunes, Sandrina; Lobo, Conceição

    2013-01-01

    To evaluate macular thickness in eyes with mild nonproliferative diabetic retinopathy (NPDR), patients with diabetes type 2, NPDR level 20 or 35, and without evidence of clinical macular edema underwent best-corrected visual acuity assessment, color fundus photography and Stratus optical coherence tomography. Mean center point thickness (CPT) and mean central subfield (CSF) thickness were compared with those of a healthy control population. 410 eyes/patients aged 61.2 ± 8.3 years, and with glycosylated hemoglobin of 7.9 ± 1.5% were included. Mean CPT and CSF were 186.6 ± 28.4 and 215.2 ± 25 µm, respectively, significantly increased compared to healthy subjects (p < 0.001). CSF thickness was abnormally increased in 17.6% of the patients, with values within the normal range in 79.5%, and abnormally decreased in 2.9%. CPT and CSF thickness were significantly thicker in men. No systemic factors showed a significant association. A significant increase in the macular thickness was found in eyes/patients with mild NPDR without clinical macular edema; however, only 17.6% of the eyes/patients had abnormally increased values and less than 3% abnormally decreased values.

  18. In vivo evidence for greater amphetamine-induced dopamine release in pathological gambling: a positron emission tomography study with [(11)C]-(+)-PHNO.

    Science.gov (United States)

    Boileau, I; Payer, D; Chugani, B; Lobo, D S S; Houle, S; Wilson, A A; Warsh, J; Kish, S J; Zack, M

    2014-12-01

    Drug addiction has been associated with deficits in mesostriatal dopamine (DA) function, but whether this state extends to behavioral addictions such as pathological gambling (PG) is unclear. Here we used positron emission tomography and the D3 receptor-preferring radioligand [(11)C]-(+)-PHNO during a dual-scan protocol to investigate DA release in response to oral amphetamine in pathological gamblers (n=12) and healthy controls (n=11). In contrast with human neuroimaging findings in drug addiction, we report the first evidence that PG is associated with greater DA release in dorsal striatum (54-63% greater [(11)C]-(+)-PHNO displacement) than controls. Importantly, dopaminergic response to amphetamine in gamblers was positively predicted by D3 receptor levels (measured in substantia nigra), and related to gambling severity, allowing for construction of a mechanistic model that could help explain DA contributions to PG. Our results are consistent with a hyperdopaminergic state in PG, and support the hypothesis that dopaminergic sensitization involving D3-related mechanisms might contribute to the pathophysiology of behavioral addictions.

  19. Proto-I axial-focusing experiments

    International Nuclear Information System (INIS)

    The time-integrated axial (z) focus of the 4.5-cm-radius Proto I (1.5 MV, 500 kA) radial proton diode is presently limited to approx. 3 mm FWHM. This result is obtained with current neutralized beam transport in a gas cell with 6 Torr argon. If the vertical local divergence were the same (10 or less) as the horizontal divergence, the local divergence alone would produce a 1.5 mm FWHM focus. The axial focal size is evidently limited by time-dependent effects. These are studied by observing the beam incident upon various targets with two time-resolved pinhole cameras. The first camera observes Rutherford-scattered protons from gold targets with an array of 11 siicon PIN detectors. The second camera observes K/sub α/-fluorescence from aluminum targets with 4 independently-gated microchannel plates imaging tubes

  20. Build Axial Gradient Field by Using Axial Magnetized Permanent Rings

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Axial magnetic field produced by an axial magnetized permanent ring was studied. For two permanent rings, if they are magnetized in the same directions, a nearly uniform axial field can be produced. If they are magnetized in opposite direction,an axial gradient magnetic field can be generated, with the field range changing from -B0 to B0. A permanent magnet with a high axial gradient field was fabricated, the measured results agree with the PANDIRA calculation very well. For wider usage,it is desirable for the field gradient to be changed. Some methods to produce the variable gradient field are presented. These kinds of axial gradient magnetic field can also be used as a beam focusing for linear accelerator if the periodic field can be produced along the beam trajectory. The axial magnetic field is something like a solenoid, large stray field will leak to the outside environment if no method is taken to control them. In this paper, one method is illustrated to shield off the outside leakage field.

  1. The role of metabotropic glutamate receptor 5 in the pathogenesis of mood disorders and addiction:Combining preclinical evidence with human Positron Emission Tomography (PET studies

    Directory of Open Access Journals (Sweden)

    Sylvia eTerbeck

    2015-03-01

    Full Text Available In the present review, we deliver an overview of the involvement of metabotropic glutamate receptor 5 (mGluR5 activity and density in pathological anxiety, mood disorders and addiction. Specifically, we will describe mGluR5 studies in humans that employed Positron Emission Tomography (PET and combined the findings with preclinical animal research. This combined view of different methodological approaches — from basic neurobiological approaches to human studies — might give a more comprehensive and clinically relevant view of mGluR5 function in mental health than the view on preclinical data alone. We will also review the current research data on mGluR5 along the Research Domain Criteria (RDoC. Firstly, we found evidence of abnormal glutamate activity related to the positive and negative valence systems, which would suggest that antagonistic mGluR5 intervention has prominent anti-addictive, anti-depressive and anxiolytic effects. Secondly, there is evidence that mGluR5 plays in important role in systems for social functioning and the response to social stress. Finally, mGluR5’s important role in sleep homeostasis suggests that this glutamate receptor may play an important role in RDoC’s arousal and modulatory systems domain. Glutamate was previously mostly investigate in non-human studies, however initial human clinical PET research now also supports the hypothesis that, by mediating brain excitability, neuroplasticity and social cognition, abnormal metabotropic glutamate activity might predispose individuals to a broad range of psychiatric problems.

  2. Dissipative Axial Inflation

    CERN Document Server

    Notari, Alessio

    2016-01-01

    We analyze in detail the background cosmological evolution of a scalar field coupled to a massless abelian gauge field through an axial term $\\frac{\\phi}{f_\\gamma} F \\tilde{F}$, such as in the case of an axion. Gauge fields in this case are known to experience tachyonic growth and therefore can backreact on the background as an effective dissipation into radiation energy density $\\rho_R$, which which can lead to inflation without the need of a flat potential. We analyze the system, for momenta $k$ smaller than the cutoff $f_\\gamma$, including numerically the backreaction. We consider the evolution from a given static initial condition and explicitly show that, if $f_\\gamma$ is smaller than the field excursion $\\phi_0$ by about a factor of at least ${\\cal O} (20)$, there is a friction effect which turns on before that the field can fall down and which can then lead to a very long stage of inflation with a generic potential. In addition we find superimposed oscillations, which would get imprinted on any kind of...

  3. Fe-implanted 6H-SiC: Direct evidence of Fe{sub 3}Si nanoparticles observed by atom probe tomography and {sup 57}Fe Mössbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Diallo, M. L.; Fnidiki, A., E-mail: abdeslem.fnidiki@univ-rouen.fr; Lardé, R.; Cuvilly, F.; Blum, I. [Groupe de Physique des Matériaux, Université et INSA de Rouen - UMR CNRS 6634 - Normandie Université. F-76801 Saint Etienne du Rouvray (France); Lechevallier, L. [Groupe de Physique des Matériaux, Université et INSA de Rouen - UMR CNRS 6634 - Normandie Université. F-76801 Saint Etienne du Rouvray (France); Département de GEII, Université de Cergy-Pontoise, rue d' Eragny, Neuville sur Oise, 95031 Cergy-Pontoise (France); Debelle, A.; Thomé, L. [Centre de Spectrométrie Nucléaire et de Spectrométrie de Masse (CSNSM), CNRS-IN2P3-Univ. Paris-Sud 11, Bât. 108, 91405 Orsay (France); Viret, M. [Service de Physique de l' Etat Condensé (DSM/IRAMIS/SPEC), UMR 3680 CNRS, Bât. 772, Orme des Merisiers, CEA Saclay 91191 Gif sur Yvette (France); Marteau, M.; Eyidi, D.; Declémy, A. [Institut PPRIME, UPR 3346 CNRS, Université de Poitiers, ENSMA, SP2MI, téléport 2, 11 Bvd M. et P. Curie 86962 Futuroscope, Chasseneuil (France)

    2015-05-14

    In order to understand ferromagnetic ordering in SiC-based diluted magnetic semiconductors, Fe-implanted 6H-SiC subsequently annealed was studied by Atom Probe Tomography, {sup 57}Fe Mössbauer spectroscopy and SQUID magnetometry. Thanks to its 3D imaging capabilities at the atomic scale, Atom Probe Tomography appears as the most suitable technique to investigate the Fe distribution in the 6H-SiC host semiconductor and to evidence secondary phases. This study definitely evidences the formation of Fe{sub 3}Si nano-sized clusters after annealing. These clusters are unambiguously responsible for the main part of the magnetic properties observed in the annealed samples.

  4. Characterization of Multiflux Axial Compressors

    International Nuclear Information System (INIS)

    In the present work the results of analytical models of performance are compared with experimental data acquired in the multi flux axial compressor test facility, built in The Pilcaniyeu Technological Complex for the SIGMA project.We describe the experimental circuit and the data of the dispersion inside the axial compressor obtained using a tracer gas through one of the annular inlets.The attained results can be used to validate the design code for the multi flux axial compressors and SIGMA industrial plant

  5. Study of axial magnetic effect

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, Victor [IHEP, Protvino, Moscow region, 142284 Russia ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 (Russian Federation); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Chernodub, M. N. [CNRS, Laboratoire de Mathématiques et Physique Théorique, Université François-Rabelais Tours, Fédération Denis Poisson, Parc de Grandmont, 37200 Tours, France Department of Physics and Astronomy, University of Gent, Krijgslaan 281, S9, B-9000 Gent (Belgium); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Goy, V. A. [School of Natural Sciences, Far Eastern Federal University, Sukhanova street 8, Vladivostok, 690950 (Russian Federation); Landsteiner, K. [Instituto de Física Teórica UAM/CSIC, C/ Nicolás Cabrera 13-15, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Molochkov, A. V. [School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Ulybyshev, M. [ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 Russia Institute for Theoretical Problems of Microphysics, Moscow State University, Moscow, 119899 (Russian Federation)

    2016-01-22

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T{sup 2} behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction.

  6. Axial gap rotating electrical machine

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-02-23

    Direct drive rotating electrical machines with axial air gaps are disclosed. In these machines, a rotor ring and stator ring define an axial air gap between them. Sets of gap-maintaining rolling supports bear between the rotor ring and the stator ring at their peripheries to maintain the axial air gap. Also disclosed are wind turbines using these generators, and structures and methods for mounting direct drive rotating electrical generators to the hubs of wind turbines. In particular, the rotor ring of the generator may be carried directly by the hub of a wind turbine to rotate relative to a shaft without being mounted directly to the shaft.

  7. Multiplanner spine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. K.; Jeon, H. J.; Hong, K. C.; Chung, K. B.; Suh, W. H. [Korea University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    The computed tomography is useful in evaluation of bony structures and adjacent soft tissues of the spine. Recently, the multiplanar spine CT scan is highly superior than usual axial scan, because of easily demonstrable longitudinal dimension, level of spine and spinal canal. We evaluated 62 cases of spine CT, whom complains of spinal symptoms, from July, 1982 to January, 1983. The results were as follows: 1. The sex distribution of cases were 45 male and 17 female, ages were from 15 years to 76 years, and sites were 15 cervical spine, 7 thoracic spine, 42 lumbar spine and 21 sacral spine. 2. Sixty two cases of the CT diagnosis were reviewed and shows 19 cases of herniated intervertebral disc, 7 cases of spine fracture, 5 cases of degenerative disease, 4 cases of metastatic cancer, 2 cases of posterior longitudinal ligament ossification, 1 case of cord injury and 24 cases of normal. 3. The CT findings of herniated intervertebral disc were protruding disc, obliteration of anterior epidural fat, with or without indentation of dural sac and calcification within posterior disc margin. In cases of trauma, the multiplanar spine CT scan detects more specific extension of the fracture sites, and it is able to demonstrate relationship between fracture fragment and spinal cord, therefore operability can be decided. In case of posterior longitudinal ligament ossification, it is easy to demonstrate linear high density along posterior margin of vertebral bodies on sagittal reconstruction scan. 4. The computed tomography is diagnostic in detection of spinal disease. However, multiplanar spine CT is more diagnostic than axial computed tomography such as detecting the longitudinal dimension and demonstration of spinal canal.

  8. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret;

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  9. Influx of Different Galapagos Plume Components to the Galapagos Spreading Center: Evidence From Sr-Nd-Pb-Hf Isotope Variations in Axial Lavas Between 86W and 92.5W

    Science.gov (United States)

    Hauff, F.; Hanan, B.; Hoernle, K. A.; Kokfelt, T. F.; Christie, D.; Werner, R.

    2006-12-01

    We present new Sr-Nd-Pb-Hf isotope data of basaltic glasses from the GSC between 86W and 92.5W. In this part of the ridge the main structural inventory includes an overlapping spreading center (OSC) at 87.3W, a transform fault (TF) at 91W and a series of seamount chains intersecting the GSC West of the 91W TF. The systematic transition from an axial-valley and rift morphology at axial depths of 2450 m.b.s.l. in the 86W area to an axial-high morphology at progressively shallower depths of 1500 m.b.s.l in the 90.5W area together with gradational changes in major and trace element chemistry of the axial lavas is believed to reflect increasing mantle temperature and compositional changes related to the Galapagos plume [1]. Previous work from 83W to 105W revealed a broad symmetric gradational pattern at around 91W and lead to the conclusion that this region is the main point of plume influx on the GSC [2]. Based on published isotope data Christie et al. (2005) inferred the probable existence of two enrichment peaks immediately East and West of the 91TF. Indeed, along axis variations of our new Sr-Nd-Pb-Hf isotope data map two distinct peaks of enrichment at 92W and 90.5W, suggesting that mantle from the Galapagos hotspot enters the GSC melting zone on both sides of the 91W transform fault. Lavas from within the 91W TF are isotopically intermediate and show a distinct depletion in incompatible trace elements, which may reflect repeated melting at shallow depth of passively upwelling mantle in this unique extensional regime. At least three different components are required to generate the observed isotope correlations. When compared to the geographically distinct isotopic domains of the Galapagos islands; GSC lavas East of the 91W TF form tight correlations from the rim of the Central Galapagos domain through the Eastern Galapagos domain towards DMM. Most axial lavas and corresponding off axis seamounts West of the 91W TF have higher 87Sr/86Sr, 207Pb/204Pb, 208Pb/204Pb

  10. Amplified Dispersive Optical Tomography

    CERN Document Server

    Goda, Keisuke; Jalali, Bahram

    2008-01-01

    Optical coherence tomography (OCT) has proven to be a powerful technique for studying tissue morphology in ophthalmology, cardiology, and endomicroscopy. Its performance is limited by the fundamental trade-off between the imaging sensitivity and acquisition speed -- a predicament common in virtually all imaging systems. In this paper, we circumvent this limit by using distributed Raman post-amplification of the reflection from the sample. We combine the amplification with simultaneously performed dispersive Fourier transformation, a process that maps the optical spectrum into an easily measured time-domain waveform. The Raman amplification enables measurement of weak signals which are otherwise buried in noise. It extends the depth range without sacrificing the acquisition speed or causing damage to the sample. As proof of concept, single-shot imaging with 15 dB improvement in sensitivity at an axial scan rate of 36.6 MHz is demonstrated.

  11. Simulation of an Axial Vircator

    CERN Document Server

    Tikhomirov, V V

    2013-01-01

    An algorithm of particle-in-cell simulations is described and tested to aid further the actual design of simple vircators working on axially symmetric modes. The methods of correction of the numerical solution, have been chosen and jointly tested, allow the stable simulation of the fast nonlinear multiflow dynamics of virtual cathode formation and evolution, as well as the fields generated by the virtual cathode. The selected combination of the correction methods can be straightforwardly generalized to the case of axially nonsymmetric modes, while the parameters of these correction methods can be widely used to improve an agreement between the simulation predictions and the experimental data.

  12. Progress in computerized body tomography

    International Nuclear Information System (INIS)

    Since computerized tomography of the head has become well-established as a most important diagnostic tool in medicine, technical advance and scientific investigation has centered on CT of the remainder of the body. A proliferation of scientific papers covering many aspects of body scanning has occured, but the evidence is only slowly emerging to establish the indications, advantages, and cost effectiveness of computerized tomography below the head. An appraisal of the present status of computerized body tomography from viewpoint of the clinical radiologist is presented. 1977 planning recommendations for the western United States are cited. (orig.) 891 MG/orig. 892 MB

  13. Facility for positron computed tomography

    International Nuclear Information System (INIS)

    For positron computed tomography two or more rings of scintillation detectors are used by which three or more sections of the object may be determined at a time. The rings are placed in parallel planes having got some distance from each other, axially movable collimator rings being provided for. Each collimator can be moved towards the opposite collimator and towards a central collimator which also is ring-shaped and is placed between the rows of detectors. The external and internal collimator are used for data selection and image-forming. (DG)

  14. Forced axial segregation in axially inhomogeneous rotating systems

    Science.gov (United States)

    González, S.; Windows-Yule, C. R. K.; Luding, S.; Parker, D. J.; Thornton, A. R.

    2015-08-01

    Controlling segregation is both a practical and a theoretical challenge. Using a novel drum design comprising concave and convex geometry, we explore, through the application of both discrete particle simulations and positron emission particle tracking, a means by which radial size segregation may be used to drive axial segregation, resulting in an order of magnitude increase in the rate of separation. The inhomogeneous drum geometry explored also allows the direction of axial segregation within a binary granular bed to be controlled, with a stable, two-band segregation pattern being reliably and reproducibly imposed on the bed for a variety of differing system parameters. This strong banding is observed to persist even in systems that are highly constrained in the axial direction, where such segregation would not normally occur. These findings, and the explanations provided of their underlying mechanisms, could lead to radical new designs for a broad range of particle processing applications but also may potentially prove useful for medical and microflow applications.

  15. Relationship between chemical structure of soil organic matter and intra-aggregate pore structure: evidence from X-ray computed micro-tomography

    Science.gov (United States)

    Kravchenko, Alexandra; Grandy, Stuart A.

    2014-05-01

    Understanding chemical structure of soil organic matter (SOM) and factors that affect it are vital for gaining understanding of mechanisms of C sequestration by soil. Physical protection of C by adsorption to mineral particles and physical disconnection between C sources and microbial decomposers is now regarded as the key component of soil C sequestration. Both of the processes are greatly influenced by micro-scale structure and distribution of soil pores. However, because SOM chemical structure is typically studied in disturbed (ground and sieved) soil samples the experimental evidence of the relationships between soil pore structure and chemical structure of SOM are still scarce. Our study takes advantage of the X-ray computed micro-tomography (µ-CT) tools that enable non-destructive analysis of pore structure in intact soil samples. The objective of this study is to examine the relationship between SOM chemical structure and pore-characteristics in intact soil macro-aggregates from two contrasting long-term land uses. The two studied land use treatments are a conventionally tilled corn-soybean-wheat rotation treatment and a native succession vegetation treatment removed from agricultural use >20 years ago. The study is located in southwest Michigan, USA, on sandy-loam Typic Hapludalfs. For this study we used soil macro-aggregates 4-6 mm in size collected at 0-15 cm depth. The aggregate size was selected so as both to enable high resolution of µ-CT and to provide sufficient amount of soil for C measurements. X-ray µ-CT scanning was conducted at APS Argonne at a scanning resolution of 14 µm. Two scanned aggregates (1 per treatment) were used in this preliminary study. Each aggregate was cut into 7 "geo-referenced" sections. Analyses of pore characteristics in each section were conducted using 3DMA and ImageJ image analysis tools. SOM chemistry was analyzed using pyrolysis/gas chromatography-mass spectroscopy. Results demonstrated that the relationships

  16. Computed Tomography (CT) -- Sinuses

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  18. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  19. Neutron tomography

    International Nuclear Information System (INIS)

    In this paper a survey is given of recent developments in selected areas of neutron tomography, within the context of several applications Argonne is involved in, including high penetration of reactor-fuel bundles in thick containers (involving TREAT and NRAD facilities), dual-energy hydrogen imaging (performed at IPNS), dynamic coarse-resolution emission tomography of rector fuel under test (a proposed modification to the TREAT hodoscope), and an associated-particle system that uses neutron flight-time to electronically collimate transmitted neutrons and to tomographically image nuclides identified by reaction gamma-rays

  20. Axially symmetric rotating traversable wormholes

    CERN Document Server

    Kuhfittig, P K F

    2003-01-01

    This paper generalizes the static and spherically symmetric traversable wormhole geometry to a rotating axially symmetric one with a time-dependent angular velocity by means of an exact solution. It was found that the violation of the weak energy condition, although unavoidable, is considerably less severe than in the static spherically symmetric case. The radial tidal constraint is more easily met due to the rotation. Similar improvements are seen in one of the lateral tidal constraints. The magnitude of the angular velocity may have little effect on the weak energy condition violation for an axially symmetric wormhole. For a spherically symmetric one, however, the violation becomes less severe with increasing angular velocity. The time rate of change of the angular velocity, on the other hand, was found to have no effect at all. Finally, the angular velocity must depend only on the radial coordinate, confirming an earlier result.

  1. Simulation of an Axial Vircator

    OpenAIRE

    Tikhomirov, V. V.; Siahlo, S. E.

    2013-01-01

    An algorithm of particle-in-cell simulations is described and tested to aid further the actual design of simple vircators working on axially symmetric modes. The methods of correction of the numerical solution, have been chosen and jointly tested, allow the stable simulation of the fast nonlinear multiflow dynamics of virtual cathode formation and evolution, as well as the fields generated by the virtual cathode. The selected combination of the correction methods can be straightforwardly gene...

  2. Seismic Tomography.

    Science.gov (United States)

    Anderson, Don L.; Dziewonski, Adam M.

    1984-01-01

    Describes how seismic tomography is used to analyze the waves produced by earthquakes. The information obtained from the procedure can then be used to map the earth's mantle in three dimensions. The resulting maps are then studied to determine such information as the convective flow that propels the crustal plates. (JN)

  3. Axial Force at the Vessel Bottom Induced by Axial Impellers

    OpenAIRE

    I. Fořt; P. Hasal; A. Paglianti; F. Magelli

    2008-01-01

    This paper deals with the axial force affecting the flat bottom of a cylindrical stirred vessel. The vessel is equipped with four radial baffles and is stirred with a four 45° pitched blade impeller pumping downwards. The set of pressure transducers is located along the whole radius of the flat bottom between two radial baffles. The radial distribution of the dynamic pressures indicated by the transducers is measured in dependence on the impeller off-bottom clearance and impeller speed.It fol...

  4. Golimumab for treatment of axial spondyloarthritis.

    Science.gov (United States)

    Rios Rodriguez, Valeria; Poddubnyy, Denis

    2016-02-01

    Axial spondyloarthritis comprises two forms: nonradiographic (nonradiographic axial spondyloarthritis) and radiographic (better known as ankylosing spondylitis), which are often considered as two stages of one disease. Historically, all currently available TNF-α inhibitors were first investigated in ankylosing spondylitis and later on in nonradiographic axial spondyloarthritis. This year, EMA has granted golimumab approval for the treatment of active nonradiographic axial spondyloarthritis based on the recently published data from the GO-AHEAD study. This article summarizes recent data on efficacy and safety of golimumab in the treatment of ankylosing spondylitis and nonradiographic axial spondyloarthritis.

  5. Experimental Demonstration of Spectral Intensity Optical Coherence Tomography

    CERN Document Server

    Ryczkowski, Piotr; Friberg, Ari T; Genty, Goëry

    2015-01-01

    We demonstrate experimentally quantum-inspired, spectral-domain intensity optical coherence tomography. We show that the technique allows for both axial resolution improvement and dispersion cancellation compared to conventional optical coherence tomography. The method does not involve scanning and it works with classical light sources and standard photodetectors. The measurements are in excellent agreement with the theoretical predictions. We also propose an approach that enables the elimination of potential artifacts arising from multiple interfaces.

  6. Atlanto-axial rotatory fixation in a girl with Spondylocarpotarsal synostosis syndrome

    Directory of Open Access Journals (Sweden)

    Grill Franz

    2006-10-01

    Full Text Available Abstract We report a 15-year-old girl who presented with spinal malsegmentation, associated with other skeletal anomalies. The spinal malsegmentation was subsequently discovered to be part of the spondylocarpotarsal synostosis syndrome. In addition, a distinctive craniocervical malformation was identified, which included atlanto-axial rotatory fixation. The clinical and the radiographic findings are described, and we emphasise the importance of computerised tomography to characterize the craniocervical malformation complex. To the best of our knowledge, this is the first clinical report of a child with spondylocarpotarsal synostosis associated with atlanto-axial rotatory fixation.

  7. Computed tomography of the spine

    International Nuclear Information System (INIS)

    Until the advent of Computed Tomography (CT), axial studies of the spine were limited in the main to gross bony anatomy and to conventional transaxial tomography (TAT). Others studied the upper cervical cord in transverse section during gas myelography and encephalography. The potential role of CT in the evaluation of spinal anatomy and disease was recognized, however, at an early stage in the development of the general purpose CT scanner. CT is not organ specific and therefore provides a uniformly thin (1.5-13 mm) axial section displaying detailed spinal topographical anatomy against a background of paravertebral muscles, vascular structures and body cavity organs. The relationships of the apophyseal joints to the spinal canal and intervertebral foramina are particularly well displayed. The study of neural tissue and pathology within the spinal canal is facilitated by the use of a non-ionic water-soluble contrast medium (viz. metrizamide) in the subarachnoid spaces. The high sensitivity of CT to very small changes in X-ray attenuation permits studies to be continued over several hours. The digital derivation of the sequential CT transaxial sections enables not only interrogation of data and quantitative studies to be made but also makes possible computer-generated reconstructions in other planes

  8. 3D SPIRAL COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF AN ABDOMINAL TUMOUR

    OpenAIRE

    R.C. Tiutiuca; Iuliana Eva

    2006-01-01

    Patients with digestive illnesses requires a full exploration, cases where imagistic assets support (echographic examination, radiological data, computed tomography, magnetic resonance) are very usefully. Computed tomography, in this process, has a special value. The results from axial images are sustained by the informations supplied from three-dimensional reconstruction processes (3D reconstruction) with relevant importance in establishment of diagnosis and therapeutic plan.

  9. Computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Caille, J.M.; Salamon, G.

    1980-01-01

    As X-ray CT becomes more commonplace, other techniques of investigation using roughly comparable hardware and software have appeared. Positron-Emission Tomography already provides indispensable physiological and physio-pathological information. Similarly, in the histo-chemical field, Nuclear Magnetic Resonance seems very promising. Some of these new techniques will no doubt shortly be considered as essential as CT in establishing accurate diagnoses non-invasively.

  10. Computerized tomography

    International Nuclear Information System (INIS)

    As X-ray Ct becomes more commonplace, other techniques of investigation using roughly comparable hardware and software have appeared. Positron-Emission Tomography already provides indispensable physiological and physio-pathological information. Similarly, in the histo-chemical field, Nuclear Magnetic Resonance seems very promising. Some of these new techniques will no doubt shortly be considered as essential as CT in establishing accurate diagnoses non-invasively. (orig./VJ)

  11. Axial Vector $Z'$ and Anomaly Cancellation

    CERN Document Server

    Ismail, Ahmed; Tsao, Kuo-Hsing; Unwin, James

    2016-01-01

    Whilst the prospect of new $Z'$ gauge bosons with only axial couplings to the Standard Model (SM) fermions is widely discussed, examples of anomaly-free renormalisable models are lacking in the literature. We look to remedy this by constructing several motivated examples. Specifically, we consider axial vectors which couple universally to all SM fermions, as well as those which are generation-specific, leptophilic, and leptophobic. Anomaly cancellation typically requires the presence of new coloured and charged chiral fermions, and we argue that the masses of these new states must generally be comparable to that of the axial vector. Finally, an axial vector mediator could provide a portal between SM and hidden sector states, and we also consider the possibility that the axial vector couples to dark matter. If the dark matter relic density is set due to freeze-out via the axial vector, this strongly constrains the parameter space.

  12. Mass Effect on Axial Charge Dynamics

    CERN Document Server

    Guo, Er-dong

    2016-01-01

    We studied effect of finite quark mass on the dynamics of axial charge using the D3/D7 model in holography. The mass term in axial anomaly equation affects both the fluctuation (generation) and dissipation of axial charge. We studied the dependence of the effect on quark mass and external magnetic field. For axial charge generation, we calculated the mass diffusion rate, which characterizes the helicity flipping rate. The rate is a non-monotonous function of mass and can be significantly enhanced by the magnetic field. The diffusive behavior is also related to a divergent susceptibility of axial charge. For axial charge dissipation, we found that in the long time limit, the mass term dissipates all the charge effectively generated by parallel electric and magnetic fields. The result is consistent with a relaxation time approximation. The rate of dissipation through mass term is a monotonous increasing function of both quark mass and magnetic field.

  13. Origin of axial current in scyllac

    International Nuclear Information System (INIS)

    The origin of the axial current observed in Scyllac (a high beta stellarator experiment) is discussed. A shaped coil and/or helical winding produce rotational transform which links magnetic lines of force to the plasma column and the axial current is induced electromagnetically. This phenomenon is inherent in a pulsed high-beta stellarator. The rotational transform produced by the induced axial current is much smaller than that associated with the l = 1, 0 equilibrium fields. The effect of the axial current on the equilibrium and stability of the plasma column is thus small. It is also shown that the magnetic field shear near a plasma surface is very strong

  14. Spinal computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sartor, K.

    1980-10-01

    Computed tomography (CT) of the spine and spinal cord is gaining more and more importance as a valuable investigative method in neuroradiology. Performed as a noninvasive procedure, with or without intravenous contrast enhancement, it can be used to diagnose paravertebral soft tissue lesions, constrictive lesions of the bony spinal canal, structure changes of the vertebral column or of individual vertebrae, vascular intraspinal lesions, and intraspinal tumors with abnormally high or abnormally low attenuation values. Performed as an invasive procedure, after intrathecal introduction of metrizamide, spinal CT can in selected cases be used in conjunction with conventional metrizamide myelography as an additional procedure (secondary CT-myelography) or even as initial procedure ( primary CT-myelography), taking advantage of its unique properties, namely to provide a transverse axial image of the spine and related soft tissue structures and to detect even small differences in density. Further improvement of spinal CT, particularly the routine non-invasive demonstration of the intraspinal soft tissues, is to be expected.

  15. Optical Coherence Tomography

    Science.gov (United States)

    ... Cardiac Magnetic Resonance Imaging (MRI and MRA) Computed Tomography (CT) Scan Diagnostic Tests and Procedures Echocardiography Electrocardiogram ... Ultrasound Nuclear Stress Test Nuclear Ventriculography Positron Emission Tomography (PET) Stress ... Optical Coherence Tomography | ...

  16. High-resolution seismic tomography of the 2015 Mw7.8 Gorkha earthquake, Nepal: Evidence for the crustal tearing of the Himalayan rift

    Science.gov (United States)

    Pei, Shunping; Liu, Hongbing; Bai, Ling; Liu, Yanbing; Sun, Quan

    2016-09-01

    The Mw7.8 Gorkha earthquake struck Nepal and ruptured the boundary between the Indian and Eurasian plates. We conducted 2-D Pg wave tomography to clarify the seismogenic structure and try to understand causal mechanisms for this large earthquake, using the aftershock data recorded by 15 broadband seismic stations located near the China-Nepal border. Our high-resolution results show that coseismic slip area of the main shock is consistent with the high P wave velocity anomaly, and the region of maximum slip has a larger area with higher velocity than the region of initial slip, possibly resulting in the dominant low-frequency radiation of energy observed after the dominant high-frequency radiation of energy in the source rupture process. The boundary between these regions of contrasting high and low seismic velocity anomalies suggests a potential crustal tearing at the southern end of the Tangra Yum Co Rift, possibly resulting from different thrust speeds in the Greater Himalaya.

  17. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  18. Health and imaging outcomes in axial spondyloarthritis

    NARCIS (Netherlands)

    Machado, P.M.

    2016-01-01

    This thesis focuses on the assessment and monitoring of health and imaging outcomes in axial spondyloarthritis (SpA) and the relationship between these outcomes. Four major contributions to the understanding and management of axial SpA were made: 1) the improvement and facilitation of the assessment

  19. More evidence for the red-shift dependence of colour from the Joint Light-curve Analysis supernova sample using red-shift tomography

    Science.gov (United States)

    Li, Miao; Li, Nan; Wang, Shuang; Zhou, Lanjun

    2016-08-01

    In this work, by applying the red-shift tomography method to the Joint Light-curve Analysis (JLA) supernova sample, we explore the possible red-shift dependence of the stretch luminosity α and the colour luminosity β. The basic idea is to divide the JLA sample into different red-shift bins, assuming that α and β are piecewise constants. Then, by constraining the ΛCDM model, we check the consistency of the cosmology-fitting results given by the supernova sample of each red-shift bin. We also adopt the same technique to explore the possible evolution of β in various subsamples of JLA. Using the full JLA data, we find that α is always consistent with a constant value. In contrast, at high red shift, β has a significant trend of decreasing, at ˜3.5σ confidence level (CL). Moreover, we find that the low-z subsample favours a constant β; in contrast, the Sloan Digital Sky Survey and Supernova Legacy Survey subsamples favour a decreasing β at 2σ and 3.3σ CL, respectively. Besides, by using a binned parametrization of β, we study the impact of the evolution of β on parameter estimation. We find that compared with a constant β, a varying β yields a larger best-fitting value of fractional matter density Ωm0, which slightly deviates from the best-fitting result given by other cosmological observations. However, for both the varying β and the constant β cases, the 1σ regions of Ωm0 are still consistent with the result given by other observations.

  20. The Sex and Race Specific Relationship between Anthropometry and Body Fat Composition Determined from Computed Tomography: Evidence from the Multi-Ethnic Study of Atherosclerosis.

    Directory of Open Access Journals (Sweden)

    Morgana Mongraw-Chaffin

    Full Text Available Few studies have investigated the relationship of anthropometric measurements with computed tomography (CT body fat composition, and even fewer determined if these relationships differ by sex and race.CT scans from 1,851 participants in the population based Multi-Ethnic Study of Atherosclerosis were assessed for visceral and subcutaneous fat areas by semi-automated segmentation of body compartments. Regression models were used to investigate relationships for anthropometry with visceral and subcutaneous fat separately by sex and race/ethnicity.Participants were 50% female, 41% Caucasian, 13% Asian, 21% African American, and 25% Hispanic. For visceral fat, the positive relationship with weight (p = 0.028, waist circumference (p<0.001, waist to hip ratio (p<0.001, and waist to height ratio (p = 0.05 differed by sex, with a steeper slope for men. That is, across the range of these anthropometric measures the rise in visceral fat is faster for men than for women. Additionally, there were differences by race/ethnicity in the relationship with height (p<0.001, weight (p<0.001, waist circumference (p<0.001, hip circumference (p = 0.006, and waist to hip ratio (p = 0.001 with the Hispanic group having shallower slopes. For subcutaneous fat, interaction by sex was found for all anthropometric indices at p<0.05, but not for race/ethnicity.The relationship between anthropometry and underlying adiposity differs by sex and race/ethnicity. When anthropometry is used as a proxy for visceral fat in research, sex-specific models should be used.

  1. Investigation of Valve Plate in Water Hydraulic Axial Piston Motor

    Institute of Scientific and Technical Information of China (English)

    聂松林; 李壮云; 等

    2002-01-01

    This paper has introduced the developments of water hydraulic axial piston equipments.According to the effects of physicochemical properties of water on water hydraulic components,a novel valve plate for water hydraulic axial motor has been put forward,whose moment exerted by the fluid field between valve plate and bearing plate is balanced entirely.The material screening experiment of valve plate is done on the test rig.Through numerical simulation the effects of some geometry parameters on the performance of water hydraulic motor have been studied.The silencing grooves on the valve plate in water hydraulic motor can reduce the pressure shock and the occurrence of cavitation effectively.It is evident that the appropriate structure should change the wear status between matching paris and reduces the wear and specific pressure of the matching pairs.The specimen with the new type valve plate is used in a tool system.

  2. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  3. [Computer tomography of sports injuries].

    Science.gov (United States)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  4. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  5. Diffraction tomography with Fourier ptychography

    CERN Document Server

    Horstmeyer, Roarke

    2015-01-01

    This article presents a method to perform diffraction tomography in a standard microscope that includes an LED array for illumination. After acquiring a sequence of intensity-only images of a thick sample, a ptychography-based reconstruction algorithm solves for its unknown complex index of refraction across three dimensions. The experimental microscope demonstrates a spatial resolution of 0.39 $\\mu$m and an axial resolution of 3.7 $\\mu$m at the Nyquist-Shannon sampling limit (0.54 $\\mu$m and 5.0 $\\mu$m at the Sparrow limit, respectively), across a total imaging volume of 2.2 mm $\\times$ 2.2 mm $\\times$ 110 $\\mu$m. Unlike competing methods, the 3D tomograms presented in this article are continuous, quantitative, and formed without the need for interferometry or any moving parts. Wide field-of-view reconstructions of thick biological specimens demonstrate potential applications in pathology and developmental biology.

  6. Axial force measurement for esophageal function testing

    Institute of Scientific and Technical Information of China (English)

    Flemming H Gravesen; Peter Funch-Jensen; Hans Gregersen; Asbjφrn Mohr Drewes

    2009-01-01

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.

  7. Axial force measurement for esophageal function testing.

    Science.gov (United States)

    Gravesen, Flemming H; Funch-Jensen, Peter; Gregersen, Hans; Drewes, Asbjørn Mohr

    2009-01-14

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method. PMID:19132762

  8. Examination of forensic entomology evidence using computed tomography scanning: case studies and refinement of techniques for estimating maggot mass volumes in bodies.

    Science.gov (United States)

    Johnson, Aidan; Archer, Melanie; Leigh-Shaw, Lyndie; Pais, Mike; O'Donnell, Chris; Wallman, James

    2012-09-01

    A new technique has recently been developed for estimating the volume of maggot masses on deceased persons using post-mortem CT scans. This allows volume to be measured non-invasively and factored into maggot mass temperature calculations for both casework and research. Examination of admission scans also allows exploration of entomological evidence in anatomical areas not usually exposed by autopsy (e.g. nasal cavities and facial sinuses), and before autopsy disrupts the maggot distribution on a body. This paper expands on work already completed by providing the x-ray attenuation coefficient by way of Hounsfield unit (HU) values for various maggot species, maggot masses and human tissue adjacent to masses. Specifically, this study looked at the HU values for four forensically important blowfly larvae: Lucilia cuprina, L. sericata, Calliphora stygia and C. vicina. The Calliphora species had significantly lower HU values than the Lucilia species. This might be explained by histological analysis, which revealed a non-significant trend, suggesting that Calliphora maggots have a higher fat content than the Lucilia maggots. It is apparent that the variation in the x-ray attenuation coefficient usually precludes its use as a tool for delineating the maggot mass from human tissue and that morphology is the dominant method for delineating a mass. This paper also includes three case studies, which reveal different applications for interpreting entomological evidence using post-mortem CT scans.

  9. New Anomaly of the Axial-Vector Current

    Institute of Scientific and Technical Information of China (English)

    HE Han-Xin

    2001-01-01

    By computing the axial-vector current operator equation, we find the anomalous axial-vector curl equation besides the well-known anomalous axial-vector divergence equation (the Adler-Bell-Jackiw anomaly) and discuss its implication.``

  10. Interleaved optical coherence tomography.

    Science.gov (United States)

    Lee, Hee Yoon; Sudkamp, Helge; Marvdashti, Tahereh; Ellerbee, Audrey K

    2013-11-01

    We present a novel and cost-effective technique--interleaved optical coherence tomography (iOCT)--to enhance the imaging speed of swept source OCT systems by acquiring data from multiple lateral positions simultaneously during a single wavelength sweep, using a single detector and a virtually imaged phase array (VIPA) as a multi-band demultiplexer. This technique uses spectral encoding to convert coherence length into higher imaging speed; the speed enhancement factor is independent of the source speed or center wavelength, and the effective A-scan rate scales linearly with sweep speed. The optical configuration requires only a change in the sample arm of a traditional OCT system and preserves the axial resolution and fall-off characteristic of a traditional SS-OCT using the same light source. Using 10 kHz, 20 kHz and 100 kHz sources we provide a first demonstration of image speed enhancement factors of up to 12, 6 and 10, respectively, which yield effective A-scan rates of 120 kHz, 120 kHz and 1 MHz for B-scan imaging, with a sensitivity of up to 82.5 dB. We also show that iOCT can image faster dynamics than traditional OCT B-scan imaging and is capable of 3D biological imaging. The iOCT concept suggests a new route to high-speed OCT imaging for laser developers: that is, by focusing on improving the coherence length and linewidth of existing and emerging sources. Hence, iOCT is a nice complement to ongoing research and commercial efforts to enable faster imaging through development of lasers with faster sweep rates, and offers new hope for existing sources with slow sweep rates and potential for enhancement of coherence length to compete with faster sources to achieve high-speed OCT. PMID:24216876

  11. ASAS classification criteria for axial spondyloarthritis: time to modify.

    Science.gov (United States)

    Akkoc, Nurullah; Khan, Muhammad A

    2016-06-01

    The relationship between ankylosing spondylitis and the recently proposed entity called axial spondyloarthritis with its radiographic and non-radiographic forms that have been defined by the Assessment of Spondyloarthritis International Society (ASAS) criteria for axial spondyloarthritis (axSpA), is currently being debated. The Food and Drug Agency (FDA) had criticized the ASAS criteria and the studies which used these criteria to enroll patients in a clinical trial of certolizumab and adalimumab for the treatment of non-radiographic axial spondyloarthritis. The primary aim of classification criteria is to create homogenous patient populations for basic and clinical research. But the multi-arm construct of the ASAS criteria is a potential source of heterogeneity reducing their utility. Criteria sets should be regarded as dynamic concepts open to modifications or updates as our knowledge advances. We provide evidence to conclude that it is time to modify the ASAS Criteria for axSpA, and we propose some of the steps that can be taken to start moving forward in improving the validity of these criteria. PMID:27094940

  12. Axial Thermal Rotation of Slender Rods

    Science.gov (United States)

    Li, Dichuan; Fakhri, Nikta; Pasquali, Matteo; Biswal, Sibani Lisa

    2011-05-01

    Axial rotational diffusion of rodlike polymers is important in processes such as microtubule filament sliding and flagella beating. By imaging the motion of small kinks along the backbone of chains of DNA-linked colloids, we produce a direct and systematic measurement of axial rotational diffusivity of rods both in bulk solution and near a wall. The measured diffusivities decrease linearly with the chain length, irrespective of the distance from a wall, in agreement with slender-body hydrodynamics theory. Moreover, the presence of small kinks does not affect the chain’s axial diffusivity. Our system and measurements provide insights into fundamental axial diffusion processes of slender objects, which encompass a wide range of entities including biological filaments and linear polymer chains.

  13. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans;

    2009-01-01

    force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...... force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been...... documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe...

  14. Nonperturbative features of the axial current

    CERN Document Server

    Kopeliovich, B Z; Siddikov, M

    2013-01-01

    In this paper we study the nonperturbative structure of the axial current and evaluate the two-point distribution amplitudes $\\int d\\xi\\, e^{-iq...\\xi}$ in the framework of the instanton vacuum model in the leading order in $\\mathcal{O}(N_{c})$. We perform a direct numerical test of the relations between the axial current and the pion distribution amplitudes, imposed by PCAC, and found excellent agreement.

  15. Nonperturbative Aspects of Axial Vector Vertex

    Institute of Scientific and Technical Information of China (English)

    ZONG Hong-Shi; CHEN Xiang-Song; WANG Fan; CHANG Chao-Hsi; ZHAO En-Guang

    2002-01-01

    It is shown how the axial vector current of current quarks is related to that of constituent quarks within the framework of the global color symmetry model.Gluon dressing of the axial vector vertex and the quark self-energy functions are described by the inhomogeneous Bethe-Salpeter equation in the ladder approximation and the Schwinger Dyson equation in the rainbow approximation,respectively.

  16. Axial Vircator for Electronic Warfare Applications

    OpenAIRE

    L. Drazan; R. Vrana

    2009-01-01

    This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM) is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered b...

  17. An Unbroken Axial Vector Current Conservation Law

    CERN Document Server

    Sharafiddinov, Rasulkhozha S

    2015-01-01

    The mass, energy and momentum of the neutrino of a true flavor have an axial-vector nature. As a consequence, the left-handed truly neutral neutrino in an axial-vector field of emission can be converted into a right-handed one and vice versa. This predicts the unidenticality of masses, energies and momenta of neutrinos of the different components. Recognizing such a difference in masses, energies, momenta and accepting that the left-handed axial-vector neutrino and the right-handed antineutrino of true neutrality refer to long-lived C-odd leptons, and the right-handed truly neutral neutrino and the left-handed axial-vector antineutrino are of short-lived fermions of C-oddity, we would write a new CP-even Dirac equation taking into account the flavor symmetrical axial-vector mass, energy and momentum matrices. Their presence explains the spontaneous mirror symmetry violation, confirming that an axial-vector current conservation law has never violated. They reflect the availability of a mirror Minkowski space i...

  18. SU(3)--Breaking Effects in Axial--Vector Couplings of Octet Baryons

    CERN Document Server

    Gensini, P M; Gensini, Paolo M.; Violini, Galileo

    1993-01-01

    Present evidence on baryon axial--vector couplings is reviewed, the main emphasis being on internal consistency between asymmetry and rate data. A complete account of all {\\sl small} terms in the Standard Model description of these latter leads to {\\sl both} consistency {\\sl and} evidence for breaking of flavour SU(3) in the axial couplings of octet baryons. Talk presented at "5th Int. Sympos. on Meson--Nucleon Physics and the Structure of the Nucleon", Boulder, CO, sept. 1993. To be published in $\\pi N$ Newsletter.

  19. Bioluminescence tomography with Gaussian prior

    OpenAIRE

    Gao, Hao; Zhao, Hongkai; Cong, Wenxiang; Wang, Ge

    2010-01-01

    Parameterizing the bioluminescent source globally in Gaussians provides several advantages over voxel representation in bioluminescence tomography. It is mathematically unique to recover Gaussians [Med. Phys. 31(8), 2289 (2004)] and practically sufficient to approximate various shapes by Gaussians in diffusive medium. The computational burden is significantly reduced since much fewer unknowns are required. Besides, there are physiological evidences that the source can be modeled by Gaussians....

  20. Sensitivity assessment of wide Axial Field of View PET systems via Monte Carlo simulations of NEMA-like measurements

    International Nuclear Information System (INIS)

    The sensitivity characteristics of Positron Emission Tomography (PET) systems with wide Axial Field of View (AFOV) was studied by MonteCarlo simulations complemented by an approximate analytical model, aiming at full-body human PET systems with AFOV in the order of 200 cm. Simulations were based on the GEANT4 package and followed closely the NEMA NU-2 1994 norm. The sensitivity, dominated by the solid angle, grows strongly with the AFOV and with the axial acceptance angle, while the scatter fraction is almost independent from the geometry

  1. Computed tomography studies of human brain movements

    International Nuclear Information System (INIS)

    Rhythmic brain movements have been revealed by sets of sequential computed tomography scans of human brains (seen retrospectively to be normal). These scans have shown that both (unenhanced) brain parenchymal density and the shapes of the elements of the supratentorial ventricular/cisternal system are subject to wave motions having similar periods - ranging from 26 s through 56 s, 77-96 s, 109 s and 224 s to 224 X 2 s (or even longer), with good correlation between peak values. These motions, as well as phase variations between the waves, suggest a peristaltic movement of cerebrospinal fluid through the ventricular/cisternal system with progressive axial damping

  2. Práticas cirúrgicas baseadas em evidências: tomografia computadorizada helicoidal no diagnóstico da apendicite aguda Evidence-based surgical practices: helical computed tomography in acute appendicitis diagnosis

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Guimarães

    2008-08-01

    Full Text Available Os cirurgiões são instados a não somente ler os artigos dos periódicos, mas também a compreendê-los e analisá-los criticamente quanto à validade. Eles cuidam melhor dos seus pacientes se são capazes de analisar criticamente a literatura e aplicar os resultados a sua prática. Este é o segundo artigo de uma série - Práticas Cirúrgicas Baseadas em Evidência - que tem por objetivo apresentar a avaliação crítica de um teste diagnóstico.Surgeons are told that they need not only read journal articles, but also understand them and make a critical appraisal of their validity. They offer better care if they are able to appraise critically the original literature and apply the results to their practice. This is the second article of a series - Evidence-Based Surgical Practices - which focus on critical appraisal of a diagnostic test.

  3. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2001-09-15

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  4. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  5. Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r2 = 0.382, mean r2 = 0.236). Similar trends were found for organ midpoint versus height (max r2 = 0.439, mean r2 = 0.200) and for organ volume versus height (max r2 = 0.410, mean r2 = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r2-values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r2 = 0.842, mean r2 = 0.790; max r2 = 0.949, mean r2 = 0.894; and max r2 = 0.870, mean r2 = 0.847, respectively). Moderate linear correlations were also observed for organ axial width versus height (max r2 = 0.772, mean r2 = 0.562) and for organ volume versus

  6. Optimization of residual heat removal pump axial thrust and axial bearing

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  8. Polarization converters based on axially symmetric twisted nematic liquid crystal.

    Science.gov (United States)

    Ko, Shih-Wei; Ting, Chi-Lun; Fuh, Andy Y-G; Lin, Tsung-Hsien

    2010-02-15

    An axially symmetric twisted nematic liquid crystal (ASTNLC) device, based on axially symmetric photoalignment, was demonstrated. Such an ASTNLC device can convert axial (azimuthal) to azimuthal (axial) polarization. The optical properties of the ASTNLC device are analyzed and found to agree with simulation results. The ASTNLC device with a specific device can be adopted as an arbitrary axial symmetric polarization converter or waveplate for axially, azimuthally or vertically polarized light. A design for converting linear polarized light to axially symmetric circular polarized light is also demonstrated. PMID:20389369

  9. Detection of hepatic tumor by means of single photon emission computed tomography, Gray scale ultrasonography, and computed tomography

    International Nuclear Information System (INIS)

    We have studied the hepatic tumor detection by single photon emission computed tomography (SPECT) using rotatory chair and gamma camera. SPECT were taken by multiple section slice not only in transaxial view, but also in frontal and sagital. The results were superior in detectability to conventional liver scintiphoto (CLS). In cases of obstructive jaundice, ultrasonography (US) and/or computed axial tomography (CAT) should be taken before SPECT, because there are various probabilities of evaluation like as false positive by means of SPECT. Simultaneous interpretation of SPECT, US, and CAT was more helpful than independent interpretation

  10. Axial instability of rotating relativistic stars

    CERN Document Server

    Friedman, J L; Friedman, John L.; Morsink, Sharon M.

    1998-01-01

    Perturbations of rotating relativistic stars can be classified by their behavior under parity. For axial perturbations (r-modes), initial data with negative canonical energy is found with angular dependence $e^{im\\phi}$ for all values of $m\\geq 2$ and for arbitrarily slow rotation. This implies instability (or marginal stability) of such perturbations for rotating perfect fluids. This low $m$-instability is strikingly different from the instability to polar perturbations, which sets in first for large values of $m$. The timescale for the axial instability appears, for small angular velocity $\\Omega$, to be proportional to a high power of $\\Omega$. As in the case of polar modes, viscosity will again presumably enforce stability except for hot, rapidly rotating neutron stars. This work complements Andersson's numerical investigation of axial modes in slowly rotating stars.

  11. Axial flow positive displacement worm gas generator

    Science.gov (United States)

    Murrow, Kurt David (Inventor); Giffin, Rollin George (Inventor); Fakunle, Oladapo (Inventor)

    2010-01-01

    An axial flow positive displacement engine has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first, second, and third sections of a core assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. The first twist slopes are less than the second twist slopes and the third twist slopes are less than the second twist slopes. A combustor section extends axially downstream through at least a portion of the second section.

  12. Improving the lattice axial vector current

    CERN Document Server

    Horsley, R; Perlt, H; Rakow, P E L; Schierholz, G; Schiller, A; Zanotti, J M

    2015-01-01

    For Wilson and clover fermions traditional formulations of the axial vector current do not respect the continuum Ward identity which relates the divergence of that current to the pseudoscalar density. Here we propose to use a point-split or one-link axial vector current whose divergence exactly satisfies a lattice Ward identity, involving the pseudoscalar density and a number of irrelevant operators. We check in one-loop lattice perturbation theory with SLiNC fermion and gauge plaquette action that this is indeed the case including order $O(a)$ effects. Including these operators the axial Ward identity remains renormalisation invariant. First preliminary results of a nonperturbative check of the Ward identity are also presented.

  13. Axial Stiffness of Multiwalled Carbon Nanotubes

    OpenAIRE

    Zavalniuk, Vladimir

    2011-01-01

    The axial stiffness of MWCNTs is demonstrated to be determined only by several external shells (usually 3-5 and up to 15 for the extremely large nanotubes and high elongations) what is in a good agreement with experimentally observed inverse relation between the radius and Young modulus (i.e., stiffness) of MWCNTs. This result is a consequence of the van der Waals intershell interaction. The interpolating formula is obtained for the actual axial stiffness of MWCNT as a function of the tube ex...

  14. Axial Vircator for Electronic Warfare Applications

    Directory of Open Access Journals (Sweden)

    L. Drazan

    2009-12-01

    Full Text Available This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered by magneto-cumulative generator and in weapons for defense of objects (WDO, it is powered by Marx generator. The possible applications of a vircator in the DEWM area are discussed.

  15. Axial loaded MRI of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Saifuddin, A. E-mail: asaifuddin@aol.com; Blease, S.; MacSweeney, E

    2003-09-01

    Magnetic resonance imaging is established as the technique of choice for assessment of degenerative disorders of the lumbar spine. However, it is routinely performed with the patient supine and the hips and knees flexed. The absence of axial loading and lumbar extension results in a maximization of spinal canal dimensions, which may in some cases, result in failure to demonstrate nerve root compression. Attempts have been made to image the lumbar spine in a more physiological state, either by imaging with flexion-extension, in the erect position or by using axial loading. This article reviews the literature relating to the above techniques.

  16. Imaging of basal cell carcinoma by high-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, M A L M; Norrenberg, S; Jemec, G B E;

    2012-01-01

    With the continued development of noninvasive therapies for basal cell carcinoma (BCC) such as photodynamic therapy and immune therapies, noninvasive diagnosis and monitoring become increasingly relevant. High-definition optical coherence tomography (HD-OCT) is a high-resolution imaging tool, wit......, with micrometre resolution in both transversal and axial directions, enabling visualization of individual cells up to a depth of around 570 μm, and filling the imaging gap between conventional optical coherence tomography (OCT) and reflectance confocal microscopy (RCM)....

  17. Role of Optical Coherence Tomography on Corneal Surface Laser Ablation

    OpenAIRE

    Ventura, Bruna V.; Moraes, Haroldo V.; Newton Kara-Junior; Santhiago, Marcony R.

    2012-01-01

    This paper focuses on reviewing the roles of optical coherence tomography (OCT) on corneal surface laser ablation procedures. OCT is an optical imaging modality that uses low-coherence interferometry to provide noninvasive cross-sectional imaging of tissue microstructure in vivo. There are two types of OCTs, each with transverse and axial spatial resolutions of a few micrometers: the time-domain and the fourier-domain OCTs. Both have been increasingly used by refractive surgeons and have spec...

  18. Optical Coherence Tomography of Retinal and Choroidal Tumors

    OpenAIRE

    Say, Emil Anthony T.; Shah, Sanket U.; Ferenczy, Sandor; Shields, Carol L.

    2011-01-01

    Optical coherence tomography (OCT) has revolutionized the field of ophthalmology since its introduction 20 years ago. Originally intended primarily for retina specialists to image the macula, it has found its role in other subspecialties that include glaucoma, cornea, and ocular oncology. In ocular oncology, OCT provides axial resolution to approximately 7 microns with cross-sectional images of the retina, delivering valuable information on the effects of intraocular tumors on the retinal arc...

  19. Parallel optical coherence tomography using a CCD camera

    Institute of Scientific and Technical Information of China (English)

    Junle Qu(屈军乐); Ravi S.Jonnal; Donald T. Miller

    2004-01-01

    Parallel optical coherence tomography is demonstrated using a 12-bit scientific-grade charge-coupled device array.A superluminescent diode in combination with a free-space Michelson interferometer was employed to achieve 10-μm axial resolution and 1.1-μm transverse resolution on a 902×575 μm2 field of view.We imaged a test mirror and bovine retinal tissue using a four-step phase shift method.

  20. Knowledge Based Design of Axial Flow Compressor

    Directory of Open Access Journals (Sweden)

    Dinesh kumar.R

    2015-05-01

    Full Text Available In the aerospace industry with highly competitive market the time to design and delivery is shortening every day. Pressure on delivering robust product with cost economy is in demand in each development. Even though technology is older, it is new for each customer requirement and highly non-liner to fit one in another place. Gas turbine is considered one of a complex design in the aircraft system. It involves experts to be grouped with designers of various segments to arrive the best output. The time is crucial to achieve a best design and it needs knowledge automation incorporated with CAD/CAE tools. In the present work an innovative idea in the form of Knowledge Based Engineering for axial compressor is proposed, this includes the fundamental design of axial compressor integrated with artificial intelligence in the form of knowledge capturing and programmed with high level language (Visual Basis.Net and embedded into CATIA v5. This KBE frame work eases out the design and modeling of axial compressor design and produces 3D modeling for further flow simulation with fluid dynamic in Ansys-Fluent. Most of the aerospace components are developed through simulation driven product development and in this case it is established for axial compressor.

  1. The Axial Current in Electromagnetic Interaction

    CERN Document Server

    Cheoun, M K; Cheon, I T; Cheoun, Myung Ki; Cheon, Il-Tong

    1998-01-01

    We discussed the possibility that the charged axial currents of matter fields could be non-conserved in electromagnetic interaction at $O(e) $ order. It means that chiral symmetry is broken explicitly by electromagnetic interaction. This explicit symmetry breaking of chiral symmetry is shown to lead the mass differences between the charged and neutral particles of matter fields.

  2. Primitive axial algebras of Jordan type

    OpenAIRE

    Hall, J I; Rehren, F; Shpectorov, S.

    2014-01-01

    An axial algebra over the field $\\mathbb F$ is a commutative algebra generated by idempotents whose adjoint action has multiplicity-free minimal polynomial. For semisimple associative algebras this leads to sums of copies of $\\mathbb F$. Here we consider the first nonassociative case, where adjoint minimal polynomials divide $(x-1)x(x-\\eta)$ for fixed $0\

  3. Axially symmetric SU(3) gravitating skyrmions

    Energy Technology Data Exchange (ETDEWEB)

    Ioannidou, Theodora [Maths Division, School of Technology, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece)]. E-mail: ti3@auth.gr; Kleihaus, Burkhard [Institut fuer Physik, Universitaet Oldenburg, Postfach 2503, D-26111 Oldenburg (Germany)]. E-mail: kleihaus@theorie.physik.uni-oldenburg.de; Zakrzewski, Wojtek [Department of Mathematical Sciences, University of Durham, Durham DH1 3LE (United Kingdom)]. E-mail: w.j.zakrzewski@durham.ac.uk

    2004-10-21

    Axially symmetric gravitating multi-skyrmion configurations are obtained using the harmonic map ansatz introduced in [J. Math. Phys. 40 (1999) 6353]. In particular, the effect of gravity on the energy and baryon densities of the SU(3) non-gravitating multi-skyrmion configurations is studied in detail.

  4. Axially symmetric SU(3) Gravitating Skyrmions

    CERN Document Server

    Ioannidou, T A; Zakrzewski, W J; Ioannidou, Theodora; Kleihaus, Burkhard; Zakrzewski, Wojtek

    2004-01-01

    Axially symmetric gravitating multi-skyrmion configurations are obtained using the harmonic map ansatz introduced in [1]. In particular, the effect of gravity on the energy and baryon densities of the SU(3) non-gravitating multi-skyrmion configurations is studied in detail.

  5. Axially symmetric SU(3) gravitating skyrmions

    International Nuclear Information System (INIS)

    Axially symmetric gravitating multi-skyrmion configurations are obtained using the harmonic map ansatz introduced in [J. Math. Phys. 40 (1999) 6353]. In particular, the effect of gravity on the energy and baryon densities of the SU(3) non-gravitating multi-skyrmion configurations is studied in detail

  6. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  7. Turbocharging Quantum Tomography.

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J; Gamble, John King,; Nielsen, Erik; Maunz, Peter Lukas Wilhelm; Scholten, Travis L.; Rudinger, Kenneth Michael

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography su %7C ers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more e %7C ectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  8. The spacetime outside a source of gravitational radiation: The axially symmetric null fluid

    CERN Document Server

    Herrera, L; Ospino, J

    2016-01-01

    We carry out a study of the exterior of an axially and reflection symmetric source of gravitational radiation. The exterior of such a source is filled with a null fluid produced by the dissipative processes inherent to the emission of gravitational radiation, thereby representing a generalization of the Vaidya metric for axially and reflection symmetric spacetimes. The role of the vorticity, and its relationship with the presence of gravitational radiation is put in evidence. The spherically symmetric case (Vaidya) is, asymptotically, recovered within the context of the $1+3$ formalism.

  9. Unusual case of infantile fibrosarcoma evaluated on F-18 fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Bedmutha, Akshay; Singh, Natasha; Shivdasani, Divya; Gupta, Nitin

    2016-01-01

    Infantile fibrosarcoma (IFS) is a rare soft-tissue sarcoma originating from extremities and occasionally from axial soft tissue. The prognosis is good with favorable long-term survival. It is rarely metastasizing tumor, the chances being lesser with IFS originating from extremities. Use of neoadjuvant chemotherapy (NACT) as a treatment regime further reduces the chances of local relapse and distant metastasis. The organs commonly affected in metastatic IFS are lungs and lymph nodes. We report an unusual case of an IFS originating from extremity, which received NACT, yet presented with an early metastatic disease involving soft tissues and sparing lungs and lymph nodes, as demonstrated on fluorodeoxyglucose positron emission tomography-computed tomography. PMID:27385891

  10. Estudo de caso de oferta induzindo a demanda: o caso da oferta de exames de imagem (tomografia axial computadorizada e ressonância magnética na Unimed-Manaus Case study of supply induced demand: the case of provision of imaging scans (computed tomography and magnetic resonance at Unimed-Manaus

    Directory of Open Access Journals (Sweden)

    Edson de Oliveira Andrade

    2011-04-01

    Full Text Available OBJETIVO: Apresentar a experiência de uma operadora de plano de saúde (Unimed-Manaus na cidade de Manaus, Estado do Amazonas, com o credenciamento de serviços de imagem e a indução de demanda pela oferta dos novos serviços (Lei de Roemer. MÉTODOS: Trata-se de uma pesquisa de caráter retrospectivo, com estudo de série temporal, abordando o período de janeiro de 1998 a junho de 2004, lapso de tempo em que ocorreu a implantação dos serviços de tomografia computadorizada e da ressonância magnética no âmbito dos serviços oferecidos por aquele plano de saúde. A análise estatística consistiu em uma parte descritiva e uma inferencial, sendo esta última utilizando teste paramétrico de média (teste t de Student e ANOVA e o teste de correlação de Pearson. Foi adotado um alfa de 5% e um intervalo de confiança de 95%. RESULTADOS: Foi possível identificar na Unimed-Manaus que a oferta de novos serviços de imagem foi capaz de, por si só, gerar um aumento da demanda do serviço caracterizando o fenômeno descrito por Roemer. CONCLUSÃO: Os resultados deste trabalho ressaltam a necessidade de se estar atento ao fato de que a oferta de novos serviços no setor da saúde poderá acarretar, por si só, um aumento de sua utilização sem que haja uma demanda real.OBJECTIVE: To present the experience of a health plan operator (Unimed-Manaus in Manaus, Amazonas, Brazil, with the accreditation of imaging services and the demand induced by the supply of new services (Roemer's Law. METHODS: This is a retrospective work studying a time series covering the period from January 1998 to June 2004, in which the computed tomography and the magnetic resonance imaging services were implemented as part of the services offered by that health plan operator. Statistical analysis consisted of a descriptive and an inferential part, with the latter using a mean parametric test (Student T-test and ANOVA and the Pearson correlation test. A 5% alpha and a 95

  11. Soft X-ray Tomography and Cryogenic Light Microscopy: The Cool Combination in Cellular Imaging

    OpenAIRE

    McDermott, Gerry; Le Gros, Mark A.; Knoechel, Christian G.; Uchida, Maho; Larabell, Carolyn A.

    2009-01-01

    Soft x-ray tomography (SXT) is ideally suited to imaging sub-cellular architecture and organization, particularly in eukaryotic cells. SXT is similar in concept to the well-established medical diagnostic technique computed axial tomography (CAT), except SXT is capable of imaging with a spatial resolution of 50 nm, or better. In soft x-ray tomography (SXT) cells are imaged using photons from a region of the spectrum known as the ‘water window’. This results in quantitative, high-contrast image...

  12. Review of Axial Burnup Distribution Considerations for Burnup Credit Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, J.C.; DeHart, M.D.

    2000-03-01

    This report attempts to summarize and consolidate the existing knowledge on axial burnup distribution issues that are important to burnup credit criticality safety calculations. Recently released Nuclear Regulatory Commission (NRC) staff guidance permits limited burnup credit, and thus, has prompted resolution of the axial burnup distribution issue. The reactivity difference between the neutron multiplication factor (keff) calculated with explicit representation of the axial burnup distribution and keff calculated assuming a uniform axial burnup is referred to as the ``end effect.'' This end effect is shown to be dependent on many factors, including the axial-burnup profile, total accumulated burnup, cooling time, initial enrichment, assembly design, and the isotopics considered (i.e., actinide-only or actinides plus fission products). Axial modeling studies, efforts related to the development of axial-profile databases, and the determination of bounding axial profiles are also discussed. Finally, areas that could benefit from further efforts are identified.

  13. Review of Axial Burnup Distribution Considerations for Burnup Credit Calculations

    International Nuclear Information System (INIS)

    This report attempts to summarize and consolidate the existing knowledge on axial burnup distribution issues that are important to burnup credit criticality safety calculations. Recently released Nuclear Regulatory Commission (NRC) staff guidance permits limited burnup credit, and thus, has prompted resolution of the axial burnup distribution issue. The reactivity difference between the neutron multiplication factor (keff) calculated with explicit representation of the axial burnup distribution and keff calculated assuming a uniform axial burnup is referred to as the ''end effect.'' This end effect is shown to be dependent on many factors, including the axial-burnup profile, total accumulated burnup, cooling time, initial enrichment, assembly design, and the isotopics considered (i.e., actinide-only or actinides plus fission products). Axial modeling studies, efforts related to the development of axial-profile databases, and the determination of bounding axial profiles are also discussed. Finally, areas that could benefit from further efforts are identified

  14. On the problem of axial anomaly in supersymmetric gauge theories

    International Nuclear Information System (INIS)

    The explicit relation is found between the axial current obeying the Adler-Bardeen theorem and the supersymmetric one belonging to a supermultiplet. It is shown that the axial and superconformal anomalies are consistent in all orders of perturbation theory

  15. Aerodynamic Modelling and Optimization of Axial Fans

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft

    of fan efficiency in a design interval of flow rates,thus designinga fan which operates well over a range of different flow conditions.The optimization scheme was used to investigate the dependence ofmaximum efficiency on1: the number of blades,2: the width of the design interval and3: the hub radius.......The degree of freedom in the choice of design variables andconstraints, combined with the design interval concept, providesa valuable design-tool for axial fans.To further investigate the use of design optimization, a modelfor the vortex shedding noise from the trailing edge of the bladeshas been......A numerically efficient mathematical model for the aerodynamics oflow speed axial fans of the arbitrary vortex flow type has been developed.The model is based on a blade-element principle, whereby therotor is divided into a number of annular streamtubes.For each of these streamtubes relations...

  16. Microwave axial dielectric properties of carbon fiber

    Science.gov (United States)

    Hong, Wen; Xiao, Peng; Luo, Heng; Li, Zhuan

    2015-10-01

    Randomly distributed carbon fibers (CFs) reinforced epoxy resin composites are prepared by the pouring method, the dielectric properties of CF composites with different fiber content and length have been performed in the frequency range from 8.2 to 12.4 GHz. The complex permittivity of the composite increases with the fiber length, which is attributed to the decrease of depolarization field, and increases with the volume fraction, which is attributed to the increase of polarization. A formula, based on the theory of Reynolds-Hugh, is proposed to calculate the effective permittivity of CF composites, and validated by the experiments. The proposed formula is further applied to derive the axial permittivity of CF and analyze the effect of fiber length on the axial permittivity.

  17. Axial flow positive displacement worm compressor

    Science.gov (United States)

    Murrow, Kurt David (Inventor); Giffin, Rollin George (Inventor); Fakunle, Oladapo (Inventor)

    2010-01-01

    An axial flow positive displacement compressor has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first and second sections of a compressor assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first and second twist slopes in the first and second sections respectively. The first twist slopes are less than the second twist slopes. An engine including the compressor has in downstream serial flow relationship from the compressor a combustor and a high pressure turbine drivingly connected to the compressor by a high pressure shaft.

  18. Extra-Axial Medulloblastoma in the Cerebellar Hemisphere

    OpenAIRE

    Chung, Eui Jin; Jeun, Sin Soo

    2014-01-01

    Extra-axial medulloblastoma is a rare phenomenon. We report a case in a 5-year-old boy who presented with nausea, vomiting, and gait disturbance. He was treated with total removal of the tumor. This is the first case of an extra-axially located medulloblastoma occurring in the cerebellar hemisphere posteriolateral to the cerebellopontine angle in Korea. Although the extra-axial occurrence of medulloblastoma is rare, it should be considered in the differential diagnosis of extra-axial lesions ...

  19. Axial flux permanent magnet brushless machines

    CERN Document Server

    Gieras, Jacek F; Kamper, Maarten J

    2008-01-01

    Axial Flux Permanent Magnet (AFPM) brushless machines are modern electrical machines with a lot of advantages over their conventional counterparts. They are being increasingly used in consumer electronics, public life, instrumentation and automation system, clinical engineering, industrial electromechanical drives, automobile manufacturing industry, electric and hybrid electric vehicles, marine vessels and toys. They are also used in more electric aircrafts and many other applications on larger scale. New applications have also emerged in distributed generation systems (wind turbine generators

  20. Axial force measurement for esophageal function testing

    OpenAIRE

    Gravesen, Flemming H; Funch-Jensen, Peter; Gregersen, Hans; Drewes, Asbjørn Mohr

    2009-01-01

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the “golden standard” for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure o...

  1. Multimode interaction in axially excited cylindrical shells

    OpenAIRE

    Silva F. M. A.; Rodrigues L.; Gonçalves P. B.; Del Prado Z. J. G. N

    2014-01-01

    Cylindrical shells exhibit a dense frequency spectrum, especially near the lowest frequency range. In addition, due to the circumferential symmetry, frequencies occur in pairs. So, in the vicinity of the lowest natural frequencies, several equal or nearly equal frequencies may occur, leading to a complex dynamic behavior. So, the aim of the present work is to investigate the dynamic behavior and stability of cylindrical shells under axial forcing with multiple equal or nearly equal natural fr...

  2. Numerical simulation of an axial blood pump.

    Science.gov (United States)

    Chua, Leok Poh; Su, Boyang; Lim, Tau Meng; Zhou, Tongming

    2007-07-01

    The axial blood pump with a magnetically suspended impeller is superior to other artificial blood pumps because of its small size. In this article, the distributions of velocity, path line, pressure, and shear stress in the straightener, the rotor, and the diffuser of the axial blood pump, as well as the gap zone were obtained using the commercial software, Fluent (version 6.2). The main focus was on the flow field of the blood pump. The numerical results showed that the axial blood pump could produce 5.14 L/min of blood at 100 mm Hg through the outlet when rotating at 11,000 rpm. However, there was a leakage flow of 1.06 L/min in the gap between the rotor cylinder and the pump housing, and thus the overall flow rate the impeller could generate was 6.2 L/min. The numerical results showed that 75% of the scalar shear stresses (SSs) were less than 250 Pa, and 10% were higher than 500 Pa within the whole pump. The high SS region appeared around the blade tip where a large variation of velocity direction and magnitude was found, which might be due to the steep angle variation at the blade tip. Because the exposure time of the blood cell at the high SS region within the pump was relatively short, it might not cause serious damage to the blood cells, but the improvement of blade profile should be considered in the future design of the axial pump. PMID:17584481

  3. Axially evoked postural reflexes: influence of task

    OpenAIRE

    Govender, Sendhil; Dennis, Danielle L.; Colebatch, James G.

    2014-01-01

    Postural reflexes were recorded in healthy subjects (n = 17) using brief axial accelerations and tap stimuli applied at the vertebra prominens (C7) and manubrium sterni. Short latency (SL) responses were recorded from the soleus, hamstrings and tibialis anterior muscles and expressed as a percentage of the background EMG prior to stimulus onset. In the majority of postural conditions tested, subjects were recorded standing erect and leaning forward with their feet together. The SL response wa...

  4. Consistent formulation of the spacelike axial gauge

    Energy Technology Data Exchange (ETDEWEB)

    Burnel, A.; Van der Rest-Jaspers, M.

    1983-12-15

    The usual formulation of the spacelike axial gauge is afflicted with the difficulty that the metric is indefinite while no ghost is involved. We solve this difficulty by introducing a ghost whose elimination is such that the metric becomes positive for physical states. The technique consists in the replacement of the gauge condition nxA = 0 by the weaker one partial/sub 0/nxAroughly-equal0.

  5. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  6. Computed tomography of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    The cranial computed tomography (CT) is a new radiological technique with which, for the first time, minimal differences an attenuation by intracranial soft tissue can be measured exactly. The basic physical principles of computed tomography have been extensively presented by Hounsfield (1973). It is well established that the attenuation of extravasated blood measures between 35 and 45 Hounsfield units. Therefore no difficulty should be encountered in the recognition and diagnosis of extra-axial hematoma and cerebral contusion since the density of the brain parenchyma never measures more than 25 units. As the constant increase in high velocity accidents and violence, the problem of acute head injury is one of the matters of great importance in today's medical practice. Therefore it is very important to figure out the method that would allow us to diagnose easily and precisely the effects of trauma upon the brain in order to institute the proper treatment at the earliest possible moment. Computed tomography allows us to make a diagnosis quickly and in a non-invasive manner. The CT scan was carried out on 310 head trauma cases in the department of radiology, St. Mary's and Kang Nam St. Mary's Hospital, Catholic Medical College, for 16 months from June 1979 to October 1980. All the scans were obtained with the Hitachi CT-H2 scanner and the scans were repeated following intravenous injection of high dose of contrast media (roughly 1.8 cc per kg body weight of 60% Conray). We have reviewed the CT scans of 310 patients got acute head injury in order to assess the location of brain lesions, the relationship between the CT densities of hematomas and their stage, the shape and mass effect of the extra-axial hematomas, and the effect of contrast enhancement. The results were as follows: 1. Of all 310 cases of the head injuries, epidural hematoma was 13.5%, subdural hematoma was 8.7%, subdural hygroma was 10%, cerebral contusion was 39%, hydrocephalus and atrophy was 3.9% and

  7. Golimumab for the treatment of axial spondyloarthritis.

    Science.gov (United States)

    Gelfer, Gita; Perry, Lisa; Deodhar, Atul

    2016-01-01

    Axial spondyloarthritis (axSpA) is a chronic, immune-mediated inflammatory disease of the axial skeleton that includes ankylosing spondylitis (AS) and non-radiographic axial spondyloarthritis (nr-axSpA). Patients with AS experience chronic pain due to sacroiliac joint and spinal inflammation, and may develop spinal ankylosing with syndesmophyte formation. Tumor necrosis factor α inhibitors (TNFi) have shown promise in the management of AS and axSpA by targeting the underlying inflammatory process, and providing symptomatic relief. Whether they alter the progression of the disease is uncertain. Golimumab is a fully human IgG1 monoclonal antibody that targets and downregulates the pro-inflammatory cytokine TNF-α. The use of golimumab has been shown to reduce the signs and symptoms of axSpA as well as improve patient function and quality reported outcomes. This review focuses on the biological rationale and the results of clinical trials with golimumab for the treatment of axSpA.

  8. Turbulence Effects of Axial Flow Hydrokinetic Turbines

    Science.gov (United States)

    Hill, C.; Chamorro, L. P.; Neary, V. S.; Morton, S.; Sotiropoulos, F.

    2011-12-01

    Axial flow hydrokinetic turbines provide a method for extracting the kinetic energy available in unidirectional (river), bidirectional (tidal) and marine currents; however, a deep understanding of the wake dynamics, momentum recovery, geomorphologic effects, and ecological interaction with these hydrokinetic turbines is required to guarantee their economical and environmental viability. The St. Anthony Falls Laboratory (SAFL) at the University of Minnesota (UMN) has performed physical modeling experiments using a 1:10 scale axial flow tidal turbine in the SAFL Main Channel, a 2.75m x 1.8m x 80m open channel test facility. A sophisticated control system allows synchronous measurements of turbine torque and rotational speed along with high resolution 3-D velocity measurements within the channel. Using acoustic Doppler velocimeters (ADVs), high resolution 3-D velocity profile data were collected up to 15 turbine diameters downstream of the turbine location. These data provide valuable information on the wake characteristics (turbulence, Reynolds stresses, etc.) resulting from a rotating axial flow hydrokinetic machine. Regions of high turbulence and shear zones that persist in the near wake regions are delineated along with the velocity deficit and momentum recovery within the wake downstream of the device. Synchronous ADV data shed light on the rotational and meandering characteristics of the wake and its potential impacts on the local geomorphology and hydrodynamic environment. This dataset on single hydrokinetic turbine flow characteristics is the basis for further work on the optimal arrangement and performance environment for arrays of similar hydrokinetic devices.

  9. DYNAMIC RESPONSES OF VISCOELASTIC AXIALLY MOVING BELT

    Institute of Scientific and Technical Information of China (English)

    李映辉; 高庆; 蹇开林; 殷学纲

    2003-01-01

    Based on the Kelvin viscoelastic differential constitutive law and the motion equation of the axially moving belt, the nonlinear dynamic model of the viscoelastic axial moving belt was established. And then it was reduced to be a linear differential system which the analytical solutions with a constant transport velocity and with a harmonically varying transport velocity were obtained by applying Lie group transformations. According to the nonlinear dynamic model, the effects of material parameters and the steady-state velocity and the perturbed axial velocity of the belt on the dynamic responses of the belts were investigated by the research of digital simulation. The result shows: 1 ) The nonlinear vibration frequency of the belt will become small when the relocity of the belt increases. 2 ) Increasing the value of viscosity or decreasing the value of elasticity leads to a deceasing in vibration frequencies. 3 ) The most effects of the transverse amplitudes come from the frequency of the perturbed velocity when the belt moves with harmonic velocity.

  10. Tomography of nonclassical states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    A review of the symplectic tomography method is presented. Superpositions of different types of photon states are considered within the framework of the tomography approach. Such nonclassical photon states as even and odd coherent states, crystallized Schrodinger cat states, and other superposition

  11. A new strategy of axial power distribution control based on three axial offsets concept

    International Nuclear Information System (INIS)

    We have proposed a very simple control procedure for axial xenon oscillation control based on a characteristic trajectory. The trajectory is drawn by three offsets of power distributions, namely, AOp, AOi and AOx. They are defined as the offset of axial power distribution, the offset of the power distribution under which the current iodine distribution is obtained as the equilibrium and that for xenon distribution, respectively. When these offsets are plotted on X-Y plane for (AOp-AOx, AOi-AOx) the trajectory draws a quite characteristic ellipse (or an elliptic spiral). On the other hands, Constant Axial Offset Control (CAOC) procedure is adopted as axial power distribution control strategy during both base load and load following operations in domestic PWRs. In the previous paper, we have presented an innovative procedure of axial power distribution control during load following in PWRs based on this trajectory such that the AOp-AOx is to be controlled to zero when the value deviates the pre-determined limiting values. In this paper we propose a modified control strategy to get more stability of axial power distributions. In this strategy, we control the trajectory to be close to the major axis of the ellipse when the power distribution reaches the limiting values. In other words, the plot is not controlled only to reduce AOp-AOx but also AOi-AOx is taken into account at the same time. It is known that when the plot is controlled to the major axis, it means that the point gives the peak position of axial xenon oscillation. Therefore xenon oscillation will not increase its amplitude any more. Thus more stable axial power distribution control is attained. This kind of design concept is quite important especially for the future PWRs with elongated fuel length and longer core life. Because in a longer effective core and also the longer core life, it has been known that the stability of axial xenon oscillation becomes more unstable. In this paper, some simulation

  12. Might axial myofascial properties and biomechanical mechanisms be relevant to ankylosing spondylitis and axial spondyloarthritis?

    Science.gov (United States)

    Masi, Alfonse T

    2014-01-01

    Ankylosing spondylitis and axial spondyloarthropathy have characteristic age- and sex-specific onset patterns, typical entheseal lesions, and marked heritability, but the integrative mechanisms causing the pathophysiological and structural alterations remain largely undefined. Myofascial tissues are integrated in the body into webs and networks which permit transmission of passive and active tensional forces that provide stabilizing support and help to control movements. Axial myofascial hypertonicity was hypothesized as a potential excessive polymorphic trait which could contribute to chronic biomechanical overloading and exaggerated stresses at entheseal sites. Such a mechanism may help to integrate many of the characteristic host, pathological, and structural features of ankylosing spondylitis and axial spondyloarthritis. Biomechanical stress and strain were recently documented to correlate with peripheral entheseal inflammation and new bone formation in a murine model of spondyloarthritis. Ankylosing spondylitis has traditionally been classified by the modified New York criteria, which require the presence of definite radiographic sacroiliac joint lesions. New classification criteria for axial spondyloarthritis now include patients who do not fulfill the modified New York criteria. The male-to-female sex ratios clearly differed between the two patient categories - 2:1 or 3:1 in ankylosing spondylitis and 1:1 in non-radiographic axial spondyloarthritis - and this suggests a spectral concept of disease and, among females, milder structural alterations. Magnetic resonance imaging of active and chronic lesions in ankylosing spondylitis and axial spondyloarthritis reveals complex patterns, usually interpreted as inflammatory reactions, but shows similarities to acute degenerative disc disease, which attributed to edema formation following mechanical stresses and micro-damage. A basic question is whether mechanically induced microinjury and immunologically mediated

  13. Abnormal access of axial vibrotactile input to deafferented somatosensory cortex in human upper limb amputees.

    Science.gov (United States)

    Kew, J J; Halligan, P W; Marshall, J C; Passingham, R E; Rothwell, J C; Ridding, M C; Marsden, C D; Brooks, D J

    1997-05-01

    input delivered to the axial body surface may gain access to the S1 hand/arm area in some humans who have suffered extensive deafferentation of this area. The findings are consistent with the hypothesis that deafferentation of an area of S1 may result in activation of previously dormant inputs from body surfaces represented in immediately adjacent parts of S1. The results also provide evidence that changes in functional connectivity between these adjacent areas of the cortex play a role in the somatotopic reorganization. PMID:9163390

  14. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Energy Technology Data Exchange (ETDEWEB)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  15. CFD Simulation of Casing Treatment of Axial Flow Compressors

    Science.gov (United States)

    DeWitt, Kenneth

    2005-01-01

    A computational study is carried out to understand the physical mechanism responsible for the improvement in stall margin of an axial flow rotor due to the circumferential casing grooves. It is shown that the computational tool used predicts an increase in operating range of the rotor when casing grooves are present. A budget of the axial momentum equation is carried out at the rotor casing in the tip gap in order to uncover the physical process behind this stall margin improvement. It is shown that for the smooth casing the net axial pressure force . However in the presence of casing grooves the net axial shear stress force acting at the casing is augmented by the axial force due to the radial transport of axial momentum, which occurs across the grooves and power stream interface. This additional force adds to the net axial viscous sheer force and thus leads to an increase in the stall margin of the rotor.

  16. Geophysical wave tomography

    Science.gov (United States)

    Zhou, Chaoguang

    2000-11-01

    This study is concerned with geophysical wave tomography techniques that include advanced diffraction tomography, traveltime calculation techniques and simultaneous attenuation and velocity tomography approaches. We propose the source independent approximation, the Modified Quasi-Linear approximation and develop a fast and accurate diffraction tomography algorithm that uses this approximation. Since the Modified Quasi-Linear approximation accounts for the scattering fields within scatterers, this tomography algorithm produces better image quality than conventional Born approximation tomography algorithm does with or without the presence of multiple scatterers and can be used to reconstruct images of high contrast objects. Since iteration is not required, this algorithm is efficient. We improve the finite difference traveltime calculation algorithm proposed by Vidale (1990). The bucket theory is utilized in order to enhance the sorting efficiency, which accounts for about ten percent computing time improvement for large velocity models. Snell's law is employed to solve the causality problem analytically, which enables the modified algorithm to compute traveltimes accurately and rapidly for high velocity contrast media. We also develop two simultaneous attenuation and velocity tomography approaches, which use traveltimes and amplitude spectra of the observed data, and discuss some of their applications. One approach is processing geophysical data that come from one single survey and the other deals with the repeated survey cases. These approaches are nonlinear and therefore more accurate than linear tomography. A linear system for wave propagation and constant-Q media are assumed in order to develop the tomography algorithms. These approaches not only produce attenuation and velocity images at the same time but also can be used to infer the physical rock properties, such as the dielectric permittivity, the electric conductivity, and the porosity. A crosshole radar

  17. Single Band Helical Antenna in Axial Mode

    Directory of Open Access Journals (Sweden)

    Parminder Singh

    2012-11-01

    Full Text Available Helical antennas have been widely used in a various useful applications, due to their low weight and low profile conformability, easy and cheap realization.Radiation properties of this antenna are examined both theoretically and experimentally. In this paper, an attempt has been made to investigate new helical antenna structure for Applications. CST MWS Software is used for the simulation and design calculations of the helical antennas. The axial ratio, return loss, VSWR, Directivity, gain, radiation pattern is evaluated. Using CST MWS simulation software proposed antenna is designed/simulated and optimized. The antenna exhibits a single band from 0 GHz to 3 GHz for GPS and several satellite applications

  18. Shaped charge with an axial channel

    Science.gov (United States)

    Malygin, A. V.; Proskuryakov, E. V.; Sorokin, M. V.; Fomin, V. M.

    2011-05-01

    A shaped charge with an axial channel is considered. The charge is initiated by an impact of an annular plate. As a result, the shaped charge is initiated at all points of the domain shaped as a ring. The impact plate material and parameters (velocity, thickness, width, and distance covered by the plate) that ensure stable penetration of the shaped charge are determined. The results obtained can be used to develop a composite (e.g., "tandem") shaped charge of the "base-head" type (the charge located farther from the target is first initiated, followed by initiation of the charge located closer to the target).

  19. Thermophoretic motion of bodies with axial symmetry

    International Nuclear Information System (INIS)

    Thermophoresis of axially symmetric bodies is investigated to first order in the Knudsen number, K n. The study is made in the limit where the typical length of the immersed body is small compared with the mean free path. It is shown that in this case, in contrast to what is the case for spherical bodies, the arising thermal force on the body is not in general anti-parallel to the temperature gradient. It is also shown that the gas exerts a torque on the body, which in magnitude and direction depends on the body geometry. Equations of motion describing the body movement are derived. Stationary solutions are studied

  20. Cervical Spine Axial Rotation Goniometer Design

    Directory of Open Access Journals (Sweden)

    Emin Ulaş Erdem

    2012-06-01

    Full Text Available To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera. With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measurement of "joint position sense" which is recently has rising interest in researches can be made practically with this goniometer.

  1. Resonances in axially symmetric dielectric objects

    CERN Document Server

    Helsing, Johan

    2016-01-01

    A high-order convergent and robust numerical solver is constructed and used to find complex eigenwavenumbers and electromagnetic eigenfields of dielectric objects with axial symmetry. The solver is based on Fourier--Nystr\\"om discretization of M\\"uller's combined integral equations for the transmission problem and can be applied to demanding resonance problems at microwave, terahertz, and optical wavelengths. High achievable accuracy, even at very high wavenumbers, makes the solver ideal for benchmarking and for assessing the performance of general purpose commercial software.

  2. Axial electron-channelling analysis of perovskite

    International Nuclear Information System (INIS)

    The orientation dependence of characteristic X-ray emission (the Borrmann effect) under near-zone-axis diffraction conditions has been used to identify the site preferences of strontium, zirconium and uranium impurities within a CaTiO3 (perovskite) host structure. As characteristic emission lines from these impurities occur at both higher and lower energies than the calcium or titanium K-shell excitations, effects of delocalization are clearly measureable, and are used as a tool in axial electron channeling or ALCHEMI analysis. It is found that strontium and uranium strongly partition into calcium sites, whereas zirconium occupies titanium sites. (author)

  3. Computed tomography findings in convergent strabismus fixus

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Michitaka; Iwashige, Hiroyasu; Hayashi, Takao; Maruo, Toshio [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1995-08-01

    X-ray computed tomography (CT) of the eyeball and orbit revealed the cause of eye movement disorder in convergent strabismus fixus. The findings suggest that the disease can be diagnosed and treated at an early stage. Twelve cases of progressive esotropia with high myopia and 20 cases with normal visual acuity served as subjects in this study. The CT slice was parallel to the German horizontal plane, and the lens and medial and lateral rectus muscles were scanned. The average axial length of the affected eyes was significantly longer than in normal eyes. In progressive esotropia, the characteristic CT findings are an elongated eyeball, mechanical contact between the eyeball and lateral wall of the orbit, and a downward displacement of the lateral rectus muscle. Thus, it is reasonable to conclude that eye movement disorder in convergent strabismus fixus results from weakness of the lateral rectus muscle which has been displaced downward due to compression of the eyeball against the orbital wall. (author).

  4. Macular Bruch's Membrane Length and Axial Length. The Beijing Eye Study.

    Directory of Open Access Journals (Sweden)

    Jost B Jonas

    Full Text Available To assess whether macular Bruch´s membrane gets lengthened in axial myopia.Using the enhanced depth imaging mode of spectral-domain optical coherence tomography and examining a subgroup of participants of the population-based cross-sectional Beijing Eye Study, we measured the length of Bruch´s membrane ("MacBMLength" from the fovea to the temporal edge of parapapillary gamma zone, and the distance between the fovea and the temporal optic disc border. Parapapillary gamma zone was defined as the parapapillary region without Bruch's membrane. We additionally measured ocular biometric parameters and assessed non-ophthalmologic variables.Measurements of MacBMLength were performed on 322 individuals. MacBMLength (mean: 3.99 ± 0.33 mm; range: 3.17-4.93 mm was not significantly associated with any systemic parameter or ocular biometric parameter. Gamma zone width (mean: 0.18 ± 0.30 mm; range: 0.00-2.61 mm was associated (multivariate analysis; correlation coefficient r:0.80 with longer axial length (P<0.001; standardized correlation coefficient beta: 0.60; non-standardized correlation coefficient B:0.11; 95%CI: 0.09,0.14 and with longer fovea-optic disc border distance (P<0.001; beta:0.28; B:0.19; 95%CI:0.14,0.25, but not with MacBMLength (P = 0.42. Fovea-temporal disc border distance (mean: 4.16 ± 0.44 mm; range: 3.17-5.86 mm was associated (overall correlation coefficient: 0.68 with longer axial length (P<0.001; beta: 0.36; B: 0.10; 95%CI: 0.06, 0.13, after adjusting for flatter anterior chamber depth (P = 0.003; beta:-0.14; B:-0.14; 95%CI: -0.23,-0.05 and wider parapapillary gamma zone (P<0.001; beta:0.42; B:0.62; 95%CI:0.44,0.81.In contrast to parapapillary gamma zone width and fovea-disc border distance, MacBMLength was not significantly associated with axial length. Axial elongation associated increase in fovea-disc distance may predominantly occur through development or elongation of parapapillary gamma zone, while macular Bruch´s membrane

  5. STEM tomography for thick biological specimens

    Energy Technology Data Exchange (ETDEWEB)

    Aoyama, Kazuhiro [FEI Company Japan Ltd., Application Laboratory, NSS-II Building, 2-13-34 Kohnan, Minato-ku, Tokyo 108-0075 (Japan)], E-mail: kazuhiro.aoyama@fei.com; Takagi, Tomoko [FEI Company Japan Ltd., Application Laboratory, NSS-II Building, 2-13-34 Kohnan, Minato-ku, Tokyo 108-0075 (Japan); Laboratory of Electron Microscopy, Japan Women' s University, 2-8-1 Mejirodai, Bunkyo-ku, Tokyo 112-8681 (Japan); Hirase, Ai; Miyazawa, Atsuo [Bio-multisome Research Team, RIKEN SPring-8 Center, Harima Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5148 (Japan); CREST, JST (Japan)

    2008-12-15

    Scanning transmission electron microscopy (STEM) tomography was applied to biological specimens such as yeast cells, HEK293 cells and primary culture neurons. These cells, which were embedded in a resin, were cut into 1-{mu}m-thick sections. STEM tomography offers several important advantages including: (1) it is effective even for thick specimens, (2) 'dynamic focusing', (3) ease of using an annular dark field (ADF) mode and (4) linear contrasts. It has become evident that STEM tomography offers significant advantages for the observation of thick specimens. By employing STEM tomography, even a 1-{mu}m-thick specimen (which is difficult to observe by conventional transmission electron microscopy (TEM)) was successfully analyzed in three dimensions. The specimen was tilted up to 73 deg. during data acquisition. At a large tilt angle, the specimen thicknesses increase dramatically. In order to observe such thick specimens, we introduced a special small condenser aperture that reduces the collection angle of the STEM probe. The specimen damage caused by the convergent electron beam was expected to be the most serious problem; however, the damage in STEM was actually smaller than that in TEM. In this study, the irradiation damage caused by TEM- and STEM-tomography in biological specimens was quantitatively compared.

  6. Atroposelective Synthesis of Axially Chiral Thiohydantoin Derivatives.

    Science.gov (United States)

    Sarigul, Sevgi; Dogan, Ilknur

    2016-07-15

    Nonracemic axially chiral thiohydantoins were synthesized atroposelectively by the reaction of o-aryl isothiocyanates with amino acid ester salts in the presence of triethylamine (TEA). The synthesis of the nonaxially chiral derivatives, however, gave thiohydantoins racemized at C-5 of the heterocyclic ring. The micropreparatively resolved enantiomers of the nonaxially chiral derivatives from the racemic products were found to be optically stable under neutral conditions. On formation of the 5-methyl-3-arylthiohydantoin ring, bulky o-aryl substituents at N3 were found to suppress the C-5 racemization and in this way enabled the transfer of chirality from the α-amino acid to the products. The corresponding 5-isopropylthiohydantoins turned out to be more prone to racemization at C-5 during the ring formation. The isomer compositions of the synthesized axially chiral thiohydantoins have been determined through HPLC analyses with chiral stationary phases. In most cases a high prevalence of the P isomers over the M isomers has been obtained. The barriers to rotation determined around the Nsp(2)-Caryl chiral axis were found to be dependent upon the size of the o-halo aryl substituents. PMID:27322739

  7. Single Rod Vibration in Axial Flow

    Science.gov (United States)

    Weichselbaum, Noah; Wang, Shengfu; Bardet, Philippe

    2013-11-01

    Fluid structure interaction of a single rod in axial flow is a coupled dynamical system present in many application including nuclear reactors, steam generators, and towed antenna arrays. Fluid-structure response can be quantified thanks to detailed experimental data where both structure and fluid responses are recorded. Such datum deepen understanding of the physics inherent to the system and provide high-dimensionality quantitative measurements to validate coupled structural and CFD codes with various level of complexity. In this work, single rods fixed on both ends in a concentric pipe, are subjected to an axial flow with Reynolds number based on hydraulic diameter of Re =4000. Rods of varying material stiffness and diameter are utilized in the experiment resulting in a range of dimensionless U between 0.5 and 1, where U = (ρA/EI)1/2uL. Experimental measurements of the velocity field around the rod are taken with PIV from time-resolved Nd:YLF laser and a high speed CMOS camera. Three-dimensional and temporal vibration and deflection of the rod is recorded with shadowgraphy utilizing two sets of pulsed high power LED and dedicated CMOS camera. Through integration of these two diagnostics, it is possible to reconstruct the full FSI domain providing unique validation data.

  8. The failure of axially loaded steel columns

    International Nuclear Information System (INIS)

    Slender compression steel members fail by elastic bucking, and short compression members may be loaded until the steel yields. In the majority of usual situations, failure occurs by inelastic buckling after a portion of the cross section has yielded. Residual stresses are the primary cause of the nonlinear protion of the average stress strain curve of axially loaded compression members (huber and Beedle, 1954). A number of theories tackled the problem of inelastic bucking. The LRFD Code ended with adopting an empirical parabolic equation that is stitched to the Euler hyperbola at the column slenderness value of λ C =2 square root and is believed to provide a reasonable approximation for column strength curves. The analysis of steel sections used in this paper defines an explicit from of failure to define the failure load of axially loaded columns in the inelastic range. inelastic bucking is defined in terms of the elaSTIC bucking of transformed sections. Two examples are used to clarify the method of analysis that accounts for residual stresses. (author). 9 refs., 5 figs

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Videos related to Computed Tomography (CT) - Head About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Images related to Computed Tomography (CT) - Sinuses About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  13. Presumed orbital sarcoidosis: report of a case followed by computerized axial tomography and conjunctival biopsy.

    Science.gov (United States)

    Nichols, C W; Mishkin, M; Yanoff, M

    1978-01-01

    A thirty-two-year old woman with known sarcoidosis was seen in the Ophthalmology Clinic because of discomfort in the left eye and orbit when looking up. A CT scan showed a small mass in the posterior left orbit. Conjunctival biopsy of the left eye showed a granuloma consistent with sarcoid. Rapid resolution of her condition occurred with prednisone therapy. One year later she had a recurrence with inability to elevate or depress the left eye. Similar, but more extensive, changes were seen on a CT scan. Conjunctival biopsy again was positive. With steroid therapy rapid and complete resolution occurred both clinically and as demonstrated by a CT scan. The relationship between her orbital mass and systemic sarcoidosis is discussed. Images FIGURE 1 A FIGURE 1 B FIGURE 1 C FIGURE 1 D FIGURE 2 A FIGURE 2 B FIGURE 2 C FIGURE 2 D FIGURE 3 A FIGURE 3 B FIGURE 3 C FIGURE 3 D FIGURE 4 A FIGURE 4 B FIGURE 4 C FIGURE 4 D FIGURE 5 A FIGURE 5 B FIGURE 5 C FIGURE 5 D PMID:754385

  14. Facial reconstruction of a 3500-year-old Egyptian mummy using axial computed tomography.

    Science.gov (United States)

    Hill, B; Macleod, I; Watson, L

    1993-01-01

    Rebuilding faces from skulls presented for forensic identification or of historical importance has been carried out for many years using standardized methods. However, the reproduction of the face of a 3500-year-old mummy still enclosed in its cartonnage proved to be an unusual challenge. The face had to be rebuilt without opening the cartonnage to ensure preservation of the remains. Consequently, the method devised involved using the latest medical imaging technology to determine the shape of the skull.

  15. The place of computerized axial tomography in the evaluation of acetabular fractures

    OpenAIRE

    Asik, Mehmet; Akman, Senol; Taser, Omer; Aritamur, Ayhan

    2004-01-01

    Besides the importance of standard AP and Judet s 45° iliac and obturator pelvic views, CAT has proved to be very useful in the evaluation of the fractures of the acetabulum. Of 96 patients with acetabular fractures, who applied to the Orthopaedics and Traumatology Department, Istanbul Medical Faculty, Istanbul University between 1987 and 1991 in addition to conventional radiography, CAT investigation was done in 32 patients for whom it was considered necessary. The results of both convention...

  16. The clinical significance of computerized axial tomography (CAT) in consideration of conventional diagnostic methods

    International Nuclear Information System (INIS)

    Regarding CAT of the intracranial region, the article informs on a) techniques of examination including the production of normal structures, b) the recognizable pathological changes, c) possibilities of enhancement, d) possibilities of course observation, e) limitations of the methods, as well as on f) risk/benefit aspects g) benefit/cost calculations as compared to conventional methods, and on h) the influence of CAT on the frequency of conventional methods of examination. Regarding CAT of the extracranial region, the information available up to the meeting is reported on. (orig./LH)

  17. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  18. Three dimensional time reversal optical tomography

    Science.gov (United States)

    Wu, Binlin; Cai, W.; Alrubaiee, M.; Xu, M.; Gayen, S. K.

    2011-03-01

    Time reversal optical tomography (TROT) approach is used to detect and locate absorptive targets embedded in a highly scattering turbid medium to assess its potential in breast cancer detection. TROT experimental arrangement uses multi-source probing and multi-detector signal acquisition and Multiple-Signal-Classification (MUSIC) algorithm for target location retrieval. Light transport from multiple sources through the intervening medium with embedded targets to the detectors is represented by a response matrix constructed using experimental data. A TR matrix is formed by multiplying the response matrix by its transpose. The eigenvectors with leading non-zero eigenvalues of the TR matrix correspond to embedded objects. The approach was used to: (a) obtain the location and spatial resolution of an absorptive target as a function of its axial position between the source and detector planes; and (b) study variation in spatial resolution of two targets at the same axial position but different lateral positions. The target(s) were glass sphere(s) of diameter ~9 mm filled with ink (absorber) embedded in a 60 mm-thick slab of Intralipid-20% suspension in water with an absorption coefficient μa ~ 0.003 mm-1 and a transport mean free path lt ~ 1 mm at 790 nm, which emulate the average values of those parameters for human breast tissue. The spatial resolution and accuracy of target location depended on axial position, and target contrast relative to the background. Both the targets could be resolved and located even when they were only 4-mm apart. The TROT approach is fast, accurate, and has the potential to be useful in breast cancer detection and localization.

  19. Axial Coordination and Conformational Heterogeneity of Nickel(II) Tetraphenylporphyrin Complexes with Nitrogenous Bases.

    Science.gov (United States)

    Jia, Song-Ling; Jentzen, Walter; Shang, Mayou; Song, Xing-Zhi; Ma, Jian-Guo; Scheidt, W. Robert; Shelnutt, John A.

    1998-08-24

    Axial ligation of nickel(II) 5,10,15,20-tetraphenylporphyrin (NiTPP) with pyrrolidine or piperidine has been investigated using X-ray crystallography, UV-visible spectroscopy, resonance Raman spectroscopy, and molecular mechanics (MM) calculations. By varying the pyrrolidine concentration in dichloromethane, distinct nu(4) Raman lines are found for the four-, five-, and six-coordinate species of NiTPP. The equilibrium constants for addition of the first and second pyrrolidine axial ligands are 1.1 and 3.8 M(-)(1), respectively. The axial ligands and their orientations influence the type and magnitude of the calculated nonplanar distortion. The differences in the calculated energies of the conformers having different ligand rotational angles are small so they may coexist in solution. Because of the similarity in macrocyclic structural parameters of these conformers and the free rotation of the axial ligands, narrow and symmetric nu(2) and nu(8) Raman lines are observed. Nonetheless, the normal-coordinate structural-decomposition analysis of the nonplanar distortions of the calculated structures and the crystal structure of the bis(piperidine) complex reveals a relationship between the orientations of axial ligand(s) and the macrocyclic distortions. For the five-coordinate complex with the plane of the axial ligand bisecting the Ni-N(pyrrole) bonds, a primarily ruffled deformation results. With the ligand plane eclipsing the Ni-N(pyrrole) bonds, a mainly saddled deformation occurs. With the addition of the second axial ligand, the small doming of the five-coordinate complexes disappears, and ruffling or saddling deformations change depending on the relative orientation of the two axial ligands. The crystal structure of the NiTPP bis(piperidine) complex shows a macrocycle distortion composed of wav(x) and wav(y) symmetric deformations, but no ruffling, saddling, or doming. The difference in the calculated and observed distortions results partly from the phenyl group

  20. Axial vascularization of a large volume calcium phosphate ceramic bone substitute in the sheep AV loop model.

    Science.gov (United States)

    Beier, Justus P; Horch, Raymund E; Hess, Andreas; Arkudas, Andreas; Heinrich, Johanna; Loew, Johanna; Gulle, Heinz; Polykandriotis, Elias; Bleiziffer, Oliver; Kneser, Ulrich

    2010-03-01

    Vascularization still remains an obstacle to engineering of bone tissue with clinically relevant dimensions. Our aim was to induce axial vascularization in a large volume of a clinically approved biphasic calcium phosphate ceramic by transferring the arteriovenous (AV) loop approach to a large animal model. HA/beta-TCP granula were mixed with fibrin gel for a total volume of 16 cm(3), followed by incorporation into an isolation chamber together with an AV loop. The chambers were implanted into the groins of merino sheep and the development of vascularization was monitored by sequential non-invasive magnetic resonance imaging (MRI). The chambers were explanted after 6 and 12 weeks, the pedicle was perfused with contrast agent and specimens were subjected to micro-computed tomography (micro-CT) scan and histological analysis. Sequential MRI demonstrated a significantly increased perfusion in the HA/beta-TCP matrices over time. Micro-CT scans and histology confirmed successful axial vascularization of HA/beta-TCP constructs. This study demonstrates, for the first time, successful axial vascularization of a clinically approved bone substitute with a significant volume in a large animal model by means of a microsurgically created AV loop, thus paving the way for the first microsurgical transplantation of a tissue-engineered, axially vascularized bone with clinically relevant dimensions.

  1. Axial stress corrosion cracking forming method to metal tube

    International Nuclear Information System (INIS)

    Generally, it is more difficult in a metal tube, to intentionally cause a stress corrosion cracking in axial direction than in circumferential direction. In the present invention, a bevel is formed on a metal tube and welding is conducted in circumferential direction along the bevel, and welding is conducted in axial direction partially to the portion welded in circumferential direction. Namely, a bevel is formed in circumferential direction to an abutting portion of thick-walled metal tubes with each other, welding is conducted in circumferential direction along the bevel, and welding is conducted in axial direction partially to a portion welded in circumferential direction. With such procedures, since tensile stress in the circumferential direction is increased partially at a portion welded in axial direction, stress corrosion cracking is caused in axial direction at the portion. Then, stress corrosion cracking in axial direction can thus be formed on the thick-walled metal tube. (N.H.)

  2. Estimation of Reversed Flow in Long Pipeline Based on Axial Vibration Model of Dense Paste

    Directory of Open Access Journals (Sweden)

    Fuyan Lyu

    2016-01-01

    Full Text Available Intense axial vibration of the paste and the reversed flow make damage to the transportation system and lag the transport progress. This paper analyzed the axial vibration of the paste by building the vibration model according to the working situations of the system. The amount of the reversed flow share is then estimated based on the formed axial vibration model. The estimation of the reversed flow is carried out by counting the amount of the decompressed paste in certain time, which is being relative to the displacement in a single process of the vibration in numerical. The estimation of the reversed flow share of coal slime paste under certain transportation conditions was given and compared with the result based on the wave velocity method. It is evident that the introduction of axial vibration model into the study of the pipeline transportation system is feasible and reasonable, which also supplements the theoretical foundation for the analysis of dense paste vibrations in pipeline transportation system and its impacts on the system.

  3. Universal Axial Algebras and a Theorem of Sakuma

    OpenAIRE

    Hall, J I; Rehren, F; Shpectorov, S.

    2013-01-01

    In the first half of this paper, we define axial algebras: nonassociative commutative algebras generated by axes, that is, semisimple idempotents---the prototypical example of which is Griess' algebra [C85] for the Monster group. When multiplication of eigenspaces of axes is controlled by fusion rules, the structure of the axial algebra is determined to a large degree. We give a construction of the universal Frobenius axial algebra on $n$ generators with a specified fusion rules, of which all...

  4. Transverse vibration characteristics of axially moving viscoelastic plate

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yin-feng; WANG Zhong-min

    2007-01-01

    The dynamic characteristics and stability of axially moving viscoelastic rectangular thin plate are investigated. Based on the two dimensional viscoelastic differential constitutive relation, the differential equations of motion of the axially moving viscoelastic plate are established. Dimensionless complex frequencies of an axially moving viscoelastic plate with four edges simply supported, two opposite edges simply supported and other two edges clamped are calculated by the differential quadrature method. The effects of the aspect ratio, moving speed and dimensionless delay time of the material on the transverse vibration and stability of the axially moving viscoelastic plate are analyzed.

  5. Composite Axial Flow Propulsor for Small Aircraft

    Directory of Open Access Journals (Sweden)

    R. Poul

    2005-01-01

    Full Text Available This work focuses on the design of an axial flow ducted fan driven by a reciprocating engine. The solution minimizes the turbulization of the flow around the aircraft. The fan has a rotor - stator configuration. Due to the need for low weight of the fan, a carbon/epoxy composite material was chosen for the blades and the driving shaft.The fan is designed for optimal isentropic efficiency and free vortex flow. A stress analysis of the rotor blade was performed using the Finite Element  Method. The skin of the blade is calculated as a laminate and the foam core as a solid. A static and dynamic analysis were made. The RTM technology is compared with other technologies and is described in detail. 

  6. Axially symmetric static sources of gravitational field

    CERN Document Server

    Hernandez-Pastora, J L; Martin, J

    2016-01-01

    A general procedure to find static and axially symmetric, interior solutions to the Einstein equations is presented. All the so obtained solutions, verify the energy conditions for a wide range of values of the parameters, and match smoothly to some exterior solution of the Weyl family, thereby representing globally regular models describing non spherical sources of gravitational field. In the spherically symmetric limit, all our models converge to the well known incompressible perfect fluid solution.The key stone of our approach is based on an ansatz allowing to define the interior metric in terms of the exterior metric functions evaluated at the boundary source. Some particular sources are obtained, and the physical variables of the energy-momentum tensor are calculated explicitly, as well as the geometry of the source in terms of the relativistic multipole moments. The total mass of different configurations is also calculated, it is shown to be equal to the monopole of the exterior solution.

  7. Dynamics of Flapping Flag in Axial Flow

    Science.gov (United States)

    Abderrahmane, Hamid Ait; Fayed, Mohamed; Gunter, Amy-Lee; Paidoussis, Michael P.; Ng, Hoi Dick

    2010-11-01

    We investigate experimentally the phenomenon of the flapping of a flag, placed within a low turbulent axial flow inside a small scale wind tunnel test section. Flags of different sizes and flexural rigidities were used. Image processing technique was used and the time series of a given point on the edge of the flag was analyzed. The stability condition of the flag was obtained and compared to the recent theoretical models and numerical simulations. Afterwards, the nonlinear dynamics of the flapping was investigated using nonlinear time series method. The nonlinear dynamics is depicted in phase space and the correlation dimension of the attractors is determined. On the basis of observations made in this study, some conclusions on the existing models were drawn.

  8. Fragmentation of an axially impacted slender rod

    Science.gov (United States)

    Ji, W.; Waas, A. M.

    2010-02-01

    Motivated by experimental results on the dynamic buckling and fragmentation of a vertical column impacted by a falling mass, results from an analytical model for dynamic buckling which considers the dynamic interaction between the axial column deformation and the out-of-plane buckling displacements are used to interpret the fragmentation process and the resulting fragment lengths. It is shown that a critical time exists for the rod to undergo fragmentation. At this critical time, the rod deforms in a modulated pattern of waves, setting up the stage for the ensuing fragmentation as a result of induced large curvatures that exceed the critical bending strain of the rod material. The resulting fragment length distributions, which show two characteristics peaks at \\frac{\\lambda}{2} and \\frac{\\lambda}{4} , where λ is a characteristic half-wavelength, are found to compare favorably with the experimental results.

  9. Axial flux data for fuel measurement

    Energy Technology Data Exchange (ETDEWEB)

    Popovich, R.P.

    1964-02-11

    A survey of the PITA-18 nonpoisonous spline program was conducted in conjunction with a study to determine the best method of eliminating the variability of axial flux on the fuel performance parameter, q. The results of this survey and the conclusions reached in the rupture coefficient study were found to be inter-dependent such that both are presented in this report. The data from the PITA-18 nonpoisonous spline program, as received, is the output of the NOLA-2 computer program. One quantity of interest is the rupture potential relative to a cosine, commonly referred to as the relative rupture potential. As programmed, the relative rupture potential, which was derived by applying the rupture model to individual fuel elements, might be expected to vary linearly with the rupture rate. The use of the relative rupture potential was studied over the period of July 1962 through December 1963. The results of this study are presented.

  10. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    The objects of this invention are first to reduce the time required to obtain statistically significant data in trans-axial tomographic radioisotope scanning using a scintillation camera. Secondly, to provide a scintillation camera system to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a known radiation source without sacrificing spatial resolution. Thirdly to reduce the scanning time without loss of image clarity. The system described comprises a scintillation camera detector, means for moving this in orbit about a cranial-caudal axis relative to a patient and a collimator having septa defining apertures such that gamma rays perpendicular to the axis are admitted with high spatial resolution, parallel to the axis with low resolution. The septa may be made of strips of lead. Detailed descriptions are given. (U.K.)

  11. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    The principal problem in trans-axial tomographic radioisotope scanning is the length of time required to obtain meaningful data. Patient movement and radioisotope migration during the scanning period can cause distortion of the image. The object of this invention is to reduce the scanning time without degrading the images obtained. A system is described in which a scintillation camera detector is moved to an orbit about the cranial-caudal axis relative to the patient. A collimator is used in which lead septa are arranged so as to admit gamma rays travelling perpendicular to this axis with high spatial resolution and those travelling in the direction of the axis with low spatial resolution, thus increasing the rate of acceptance of radioactive events to contribute to the positional information obtainable without sacrificing spatial resolution. (author)

  12. Computed tomography of juvenile nasopharyngeal angiofibroma

    International Nuclear Information System (INIS)

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma

  13. Axially symmetric Lorentzian wormholes in general relativity

    International Nuclear Information System (INIS)

    The field equations of Einstein's theory of general relativity, being local, do not fix the global structure of space-time. They admit topologically non-trivial solutions, including spatially closed universes and the amazing possibility of shortcuts for travel between distant regions in space and time - so-called Lorentzian wormholes. The aim of this thesis is to (mathematically) construct space-times which contain traversal wormholes connecting arbitrary distant regions of an asymptotically flat or asymptotically de Sitter universe. Since the wormhole mouths appear as two separate masses in the exterior space, space-time can at best be axially symmetric. We eliminate the non-staticity caused by the gravitational attraction of the mouths by anchoring them by strings held at infinity or, alternatively, by electric repulsion. The space-times are obtained by surgically grafting together well-known solutions of Einstein's equations along timelike hypersurfaces. This surgery naturally concentrates a non-zero stress-energy tensor on the boundary between the two space-times which can be investigated by using the standard thin shell formalism. It turns out that, when using charged black holes, the provided constructions are possible without violation of any of the energy conditions. In general, observers living in the axially symmetric, asymptotically flat (respectively asymptotically de Sitter) region axe able to send causal signals through the topologically non-trivial region. However, the wormhole space-times contain closed timelike curves. Because of this explicit violation of global hyperbolicity these models do not serve as counterexamples to known topological censorship theorems. (author)

  14. Green's Functions in Axial and Lorentz-type Gauges and Application to The Axial Pole Prescription and The Wilson Loop

    OpenAIRE

    Joglekar, Satish D.

    2000-01-01

    We summarize the work done in connecting Green's functions in a different classes of gauges and its applications to the problems in the axial gauges.The procedure adopted uses finite field-dependent BRS [FFBRS] transformations to connect axial and the Lorentz type gauges.These transformations preserve the vacuum expectation of gauge-invariant observables explicitly. We discuss the applications of these ideas to the axial gauge pole problem and to the preservation of the Wilson loop and the th...

  15. Ultrahigh resolution optical coherence tomography with femtosecond Ti:sapphire laser and photonic crystal fiber

    Institute of Scientific and Technical Information of China (English)

    XUE Ping; James G FUJIMOTO

    2008-01-01

    Optical coherence tomography (OCT) with ultrahigh axial resolution was achieved by the super-contin- uum generated by coupling femtosecond pulses from a commercial Ti :sapphire laser into an air-silica microstructure fiber. The visible spectrum of the super-continuum from 450 to 700 nm centered at 540 nm can be generated. A free-space axial OCT resolution of 0.64 IJm was achieved. The sensitivity of OCT system was 108 dB with incident light power 3 mW at sample, only 7dB below the theoretical limit. Subcellular OCT imaging was also demonstrated, showing great potential for biomedical application.

  16. Adaptive optics optical coherence tomography for retina imaging

    Institute of Scientific and Technical Information of China (English)

    Guohua Shi; Yun Dai; Ling Wang; Zhihua Ding; Xuejun Rao; Yudong Zhang

    2008-01-01

    When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 frames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented.

  17. Nano-sensitive optical coherence tomography

    Science.gov (United States)

    Alexandrov, Sergey A.; Subhash, Hrebesh M.; Zam, Azhar; Leahy, Martin

    2014-03-01

    Depth resolved label-free detection of structural changes with nanoscale sensitivity is an outstanding problem in the biological and physical sciences and has significant applications in both the fundamental research and healthcare diagnostics arenas. Here we experimentally demonstrate a novel label-free depth resolved sensing technique based on optical coherence tomography (OCT) to detect structural changes at the nanoscale. Structural components of the 3D object, spectrally encoded in the remitted light, are transformed from the Fourier domain into each voxel of the 3D OCT image without compromising sensitivity. Spatial distribution of the nanoscale structural changes in the depth direction is visualized in just a single OCT scan. This label free approach provides new possibilities for depth resolved study of pathogenic and physiologically relevant molecules in the body with high sensitivity and specificity. It offers a powerful opportunity for early diagnosis and treatment of diseases. Experimental results show the ability of the approach to differentiate structural changes of 30 nm in nanosphere aggregates, located at different depths, from a single OCT scan, and structural changes less than 30 nm in time from two OCT scans. Application for visualization of the structure of human skin in vivo is also demonstrated.Depth resolved label-free detection of structural changes with nanoscale sensitivity is an outstanding problem in the biological and physical sciences and has significant applications in both the fundamental research and healthcare diagnostics arenas. Here we experimentally demonstrate a novel label-free depth resolved sensing technique based on optical coherence tomography (OCT) to detect structural changes at the nanoscale. Structural components of the 3D object, spectrally encoded in the remitted light, are transformed from the Fourier domain into each voxel of the 3D OCT image without compromising sensitivity. Spatial distribution of the nanoscale

  18. Computed Tomography Imaging of the Topographical Anatomy of Canine Prostate

    International Nuclear Information System (INIS)

    AIM: To investigate the topographical anatomy of canine prostate gland by computed tomography (CT) for diagnostic imaging purposes. ÐœATERIAL AND METHODS: Seven clinically healthy mongrel male dogs at the age of 3−4 years and body weight of 10−15 kg were submitted to transverse computerized axial tomography (CAT) with cross section thickness of 5 mm. RESULTS: The CT image of canine prostate is visualized throughout the scans of the pelvis in the planes through the first sacral vertebra (S1) dorsally; the bodies of iliac bones laterally and cranially to the pelvic brim (ventrally). The body of prostate appears as an oval homogenous relatively hypo dense finding with soft tissue density. The gland is well differentiated from the adjacent soft tissues. CONCLUSION: By means of CT, the cranial part of prostate gland in adult dogs aged 3−4 years exhibited an abdominal localization. (author)

  19. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  20. Practical Bayesian Tomography

    CERN Document Server

    Granade, Christopher; Cory, D G

    2015-01-01

    In recent years, Bayesian methods have been proposed as a solution to a wide range of issues in quantum state and process tomography. State-of- the-art Bayesian tomography solutions suffer from three problems: numerical intractability, a lack of informative prior distributions, and an inability to track time-dependent processes. Here, we solve all three problems. First, we use modern statistical methods, as pioneered by Husz\\'ar and Houlsby and by Ferrie, to make Bayesian tomography numerically tractable. Our approach allows for practical computation of Bayesian point and region estimators for quantum states and channels. Second, we propose the first informative priors on quantum states and channels. Finally, we develop a method that allows online tracking of time-dependent states and estimates the drift and diffusion processes affecting a state. We provide source code and animated visual examples for our methods.

  1. Ocean acoustic reverberation tomography.

    Science.gov (United States)

    Dunn, Robert A

    2015-12-01

    Seismic wide-angle imaging using ship-towed acoustic sources and networks of ocean bottom seismographs is a common technique for exploring earth structure beneath the oceans. In these studies, the recorded data are dominated by acoustic waves propagating as reverberations in the water column. For surveys with a small receiver spacing (e.g., tomography, is developed that uses the travel times of direct and reflected waves to image ocean acoustic structure. Reverberation tomography offers an alternative approach for determining the structure of the oceans and advancing the understanding of ocean heat content and mixing processes. The technique has the potential for revealing small-scale ocean thermal structure over the entire vertical height of the water column and along long survey profiles or across three-dimensional volumes of the ocean. For realistic experimental geometries and data noise levels, the method can produce images of ocean sound speed on a smaller scale than traditional acoustic tomography. PMID:26723303

  2. Ocean acoustic reverberation tomography.

    Science.gov (United States)

    Dunn, Robert A

    2015-12-01

    Seismic wide-angle imaging using ship-towed acoustic sources and networks of ocean bottom seismographs is a common technique for exploring earth structure beneath the oceans. In these studies, the recorded data are dominated by acoustic waves propagating as reverberations in the water column. For surveys with a small receiver spacing (e.g., ocean acoustic reverberation tomography, is developed that uses the travel times of direct and reflected waves to image ocean acoustic structure. Reverberation tomography offers an alternative approach for determining the structure of the oceans and advancing the understanding of ocean heat content and mixing processes. The technique has the potential for revealing small-scale ocean thermal structure over the entire vertical height of the water column and along long survey profiles or across three-dimensional volumes of the ocean. For realistic experimental geometries and data noise levels, the method can produce images of ocean sound speed on a smaller scale than traditional acoustic tomography.

  3. Neutron Computed Tomography

    International Nuclear Information System (INIS)

    Computed tomography is a non-destructive testing method which can visualize cross-section of materials based on their nuclear characteristics. In the previous work, X-ray was used as its radiation media. The aim of this experiment was to improve the computed tomography technique using neutron beam. For reconstructing the cross-section image of materials, a filtered back projection was used. Result indicated that a minimum hole shown was 3 mm in diameter using a black and white presentation. While using eight colour levels, a hole of 2 mm in diameter could be seen clearly. It is expected that neutron computed tomography can improve the results of non-destructive testing. (author). 5 refs., 6 figs

  4. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  5. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  6. Emission tomography: Physical aspects

    International Nuclear Information System (INIS)

    Two different approaches have been followed: i/ tomography by single gamma-photon counting (SPC), using either conventional scintillation cameras or specially designed detector arrays. These systems use radionuclides which are readily available commercially (99 mTc, 131 I, 201 Tl); ii/ positron-emission tomography (ACD) which relies on the simultaneous and colinear emission of two 511 keV gamma photons, permitting a higher detection efficiency and effective 'electronic collimation'. These factors give good spatial resolution and quantitative precision. The principal positron-emitting isotopes 11 C, 13 N, 150 O can also serve as tracers in a very wide range of biological processes. (orig./VJ)

  7. Atom Probe Tomography 2012

    Science.gov (United States)

    Kelly, Thomas F.; Larson, David J.

    2012-08-01

    In the world of tomographic imaging, atom probe tomography (APT) occupies the high-spatial-resolution end of the spectrum. It is highly complementary to electron tomography and is applicable to a wide range of materials. The current state of APT is reviewed. Emphasis is placed on applications and data analysis as they apply to many fields of research and development including metals, semiconductors, ceramics, and organic materials. We also provide a brief review of the history and the instrumentation associated with APT and an assessment of the existing challenges in the field.

  8. Improved axial position detection in optical tweezers measurements

    DEFF Research Database (Denmark)

    Dreyer, Jakob Kisbye; Berg-Sørensen, Kirstine; Oddershede, Lene

    2004-01-01

    We investigate the axial position detection of a trapped microsphere in an optical trap by using a quadrant photodiode. By replacing the photodiode with a CCD camera, we obtain detailed information on the light scattered by the microsphere. The correlation of the interference pattern with the axial...

  9. Through flow analysis within axial flow turbomachinery blade rows

    Science.gov (United States)

    Girigoswami, H.

    1986-09-01

    Using Katsanis' Through Flow Code, inviscid flow through an axial flow compressor rotor blade as well as flow through inlet guide vanes are analyzed and the computed parameters such as meridional velocity distribution, axial velocity distribution along radial lines, and velocity distribution over blade surfaces are presented.

  10. Test Setup for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test setup for testing axially static and cyclic loaded piles in sand is described in the following. The purpose for the tests is to examine the tensile capacity of axially loaded piles in dense fully saturated sand. The pile dimensions are chosen to resemble full scale dimension of piles used...... in offshore pile foundations today....

  11. Pre-bilaterian origin of the blastoporal axial organizer

    Science.gov (United States)

    Kraus, Yulia; Aman, Andy; Technau, Ulrich; Genikhovich, Grigory

    2016-01-01

    The startling capacity of the amphibian Spemann organizer to induce naïve cells to form a Siamese twin embryo with a second set of body axes is one of the hallmarks of developmental biology. However, the axis-inducing potential of the blastopore-associated tissue is commonly regarded as a chordate feature. Here we show that the blastopore lip of a non-bilaterian metazoan, the anthozoan cnidarian Nematostella vectensis, possesses the same capacity and uses the same molecular mechanism for inducing extra axes as chordates: Wnt/β-catenin signaling. We also demonstrate that the establishment of the secondary, directive axis in Nematostella by BMP signaling is sensitive to an initial Wnt signal, but once established the directive axis becomes Wnt-independent. By combining molecular analysis with experimental embryology, we provide evidence that the emergence of the Wnt/β-catenin driven blastopore-associated axial organizer predated the cnidarian-bilaterian split over 600 million years ago. PMID:27229764

  12. Fabrication and Experimental Analysis of Axially Oriented Nanofibers.

    Science.gov (United States)

    Aphale, Ashish N; Mahakalkar, Kapil; Macwan, Isaac G; Mukerji, Ishita; Cox, Paris J; Mahapatra, Manoj; Singh, Prabhakar; Ajayan, Pulickel M; Patra, Prabir K

    2016-03-01

    A novel design of a laboratory built axially rotating collector (ARC) having capability to align electrospun nanofibers have been described. A detailed morphological comparison of such nanofibers orientation and their geometry is done using scanning electron microscopy (SEM). For comparison various polymeric solutions were electrospun on conventional static collector as well as ARC. The average diameter of polyvinyl alcohol (PVA) nanofibers was found to be 250 nm while polycaprolactone (PCL) nanofibers were found to be within a range of 600-800 nm. Conducting nanoparticles such as graphene and multi-walled carbon nanotubes (MWNTs) mixed with polymer solutions shown to have a significant influence on the overall geometry of these nanofibers and their diameter distribution. It is evident from the SEM analysis that both graphene and MWNTs in polymer solution play a crucial role in achieving a uniform diameter of nanofibers. Lastly, the formation of the aligned nanofibers using ARC has been mathematically modeled and the electromagnetic field governing the process has been simulated. PMID:27455687

  13. The Definition and Measurement of Axial Psoriatic Arthritis.

    Science.gov (United States)

    Lubrano, Ennio; Parsons, Wendy Joanne; Marchesoni, Antonio; Olivieri, Ignazio; D'Angelo, Salvatore; Cauli, Alberto; Caso, Francesco; Costa, Luisa; Scarpa, Raffaele; Brunese, Luca

    2015-11-01

    This review seeks to update the state of the art of axial psoriatic arthritis (axPsA). The definition and assessment of axPsA can be problematic because no agreement and no definitive data on this topic have been published, resulting in uncertainty as to the best approach to deal with these patients. A few recent scientific reports show new data on the possible coincidence of diffuse idiopathic skeletal hyperostosis and axPsA, as well as on the radiological assessment as measured with the validated instruments for axPsA. Moreover, the role of magnetic resonance imaging has also been evaluated for this intriguing subset. All data confirmed that radiological assessment is a useful tool to detect typical findings of axPsA, while other imaging techniques remain to be validated. Finally, there is no evidence to support treatment of axPsA with traditional disease-modifying antirheumatic drugs, while a "leap" to biologic agents is the only treatment after failure with nonsteroidal antiinflammatory drugs.

  14. On Stationary Axially Symmetric Solutions in Brans-Dicke Theory

    CERN Document Server

    Kirezli, Pınar

    2015-01-01

    Stationary axially symmetric Brans-Dicke-Maxwell solutions are re-examined in the framework of the Brans-Dicke theory. We see that, employing a particular parametrization of the standard axially symmetric metric simplifies the procedure of obtaining the Ernst equations for axially symmetric electro-vacuum space-times for this theory. This analysis also permit us to construct a two parameter extension in both Jordan and Einstein frames of an old solution generating technique frequently used to construct axially symmetric solutions for Brans-Dicke theory from a seed solution of General Relativity. As applications of this technique, several known and new solutions are constructed including a general axially symmetric BD-Maxwell solution of Plebanski-Demianski with vanishing cosmological constant, i.e. the Kinnersley solution and general magnetized Kerr-Newman type solutions. Some physical properties and circular motion of test particles for a particular subclass of Kinnersley solution, i.e. Kerr-Newman-NUT type ...

  15. Quantitative analysis of cone photoreceptor distribution and its relationship with axial length, age, and early age-related macular degeneration.

    Directory of Open Access Journals (Sweden)

    Ryo Obata

    Full Text Available PURPOSE: It has not been clarified whether early age-related macular degeneration (AMD is associated with cone photoreceptor distribution. We used adaptive optics fundus camera to examine cone photoreceptors in the macular area of aged patients and quantitatively analyzed its relationship between the presence of early AMD and cone distribution. METHODS: Sixty cases aged 50 or older were studied. The eyes were examined with funduscopy and spectral-domain optical coherence tomography to exclude the eyes with any abnormalities at two sites of measurement, 2° superior and 5° temporal to the fovea. High-resolution retinal images with cone photoreceptor mosaic were obtained with adaptive optics fundus camera (rtx1, Imagine Eyes, France. After adjusting for axial length, cone packing density was calculated and the relationship with age, axial length, or severity of early AMD based on the age-related eye disease study (AREDS classification was analyzed. RESULTS: Patient's age ranged from 50 to 77, and axial length from 21.7 to 27.5 mm. Mean density in metric units and that in angular units were 24,900 cells/mm2, 2,170 cells/deg2 at 2° superior, and 18,500 cells/mm2, 1,570 cels/deg2 at 5° temporal, respectively. Axial length was significantly correlated with the density calculated in metric units, but not with that in angular units. Age was significantly correlated with the density both in metric and angular units at 2° superior. There was no significant difference in the density in metric and angular units between the eyes with AREDS category one and those with categories two or three. CONCLUSION: Axial length and age were significantly correlated with parafoveal cone photoreceptor distribution. The results do not support that early AMD might influence cone photoreceptor density in the area without drusen or pigment abnormalities.

  16. New classes of bi-axially symmetric solutions to four-dimensional Vasiliev higher spin gravity

    CERN Document Server

    Sundell, Per

    2016-01-01

    We present new infinite-dimensional spaces of bi-axially symmetric asymptotically anti-de Sitter solutions to four-dimensional Vasiliev higher spin gravity, obtained by modifications of the Ansatz used in arXiv:1107.1217, which gave rise to a Type-D solution space. The current Ansatz is based on internal semigroup algebras (without identity) generated by exponentials formed out of the bi-axial symmetry generators. After having switched on the vacuum gauge function, the resulting generalized Weyl tensor is given by the sum of two generalized Petrov type-D tensors, and the twistor space connections are smooth in twistor space over finite regions of spacetime. We provide evidence for that the linearized twistor space connection can be brought to Vasiliev gauge.

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  18. Multimode interaction in axially excited cylindrical shells

    Directory of Open Access Journals (Sweden)

    Silva F. M. A.

    2014-01-01

    Full Text Available Cylindrical shells exhibit a dense frequency spectrum, especially near the lowest frequency range. In addition, due to the circumferential symmetry, frequencies occur in pairs. So, in the vicinity of the lowest natural frequencies, several equal or nearly equal frequencies may occur, leading to a complex dynamic behavior. So, the aim of the present work is to investigate the dynamic behavior and stability of cylindrical shells under axial forcing with multiple equal or nearly equal natural frequencies. The shell is modelled using the Donnell nonlinear shallow shell theory and the discretized equations of motion are obtained by applying the Galerkin method. For this, a modal solution that takes into account the modal interaction among the relevant modes and the influence of their companion modes (modes with rotational symmetry, which satisfies the boundary and continuity conditions of the shell, is derived. Special attention is given to the 1:1:1:1 internal resonance (four interacting modes. Solving numerically the governing equations of motion and using several tools of nonlinear dynamics, a detailed parametric analysis is conducted to clarify the influence of the internal resonances on the bifurcations, stability boundaries, nonlinear vibration modes and basins of attraction of the structure.

  19. What is Computed Tomography?

    Science.gov (United States)

    ... word "tomography" is from the Greek word "tomos" meaning "slice" or "section" and "graphe" meaning "drawing." A CT imaging system produces cross-sectional ... The patient may receive an injection of a "contrast material" to facilitate visualization of vascular structure. Detectors ...

  20. Holography and tomography

    Energy Technology Data Exchange (ETDEWEB)

    Howells, M. [Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography.

  1. Waste inspection tomography (WIT)

    International Nuclear Information System (INIS)

    The WIT program will provide an inspection system that offers the nuclear waste evaluator a unique combination of tools for regulatory-driven characterization of low-level waste (LLW), transuranic waste (TRU), and mixed waste drums. WIT provides nondestructive, noninvasive, and environmentally safe inspections using X-ray and gamma ray technologies, with reasonable cost and throughput. Two emission imaging techniques will be employed for characterizing materials in waste containers. The first of these is gamma emission tomography, commonly called single-photon emission computed tomography (SPECT). Rather than using an external radiation source, SPECT uses the emission of radioactive materials within the object of interest for imaging. In this case, emission from actual nuclear waste within a container will provide a three-dimensional image of the radioactive substances in the container. The second emission technique will use high-purity germanium detectors for gamma ray spectroscopy. This technique, called nondestructive assay (NDA), can identify the emitting isotopic species and strength. Work in emission tomography and assay of nuclear waste has been undertaken at Lawrence Livermore National Laboratory using a technique called Passive Tomography. Results from a process development unit are presented

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  4. Dental Optical Coherence Tomography

    OpenAIRE

    Kun-Feng Lin; Jui-che Tsai; Ching-Cheng Chuang; Shyh-Yuan Lee; Yi-Ching Ho; Yao-Sheng Hsieh; Chia-Wei Sun

    2013-01-01

    This review paper describes the applications of dental optical coherence tomography (OCT) in oral tissue images, caries, periodontal disease and oral cancer. The background of OCT, including basic theory, system setup, light sources, spatial resolution and system limitations, is provided. The comparisons between OCT and other clinical oral diagnostic methods are also discussed.

  5. Angular and axial deformities of the legs of children.

    Science.gov (United States)

    McDonough, M W

    1984-12-01

    Age is often a determining factor in establishing a treatment program for these axial and angular problems. As can be seen, the deformities of torsion are noticeable from early life. Any tibial torsion should be treated early, but an excessive medial range of motion in the infant leg with a corresponding adequate lateral range of motion of the limb may be cautiously observed. Medial femoral torsion is a normal early finding in the infant thigh. The problem becomes evident as the child matures without the corresponding reduction in femoral torsion, leading to a persistence of fetal or infantile alignment. The gait consequences are usually noticed at 4 to 8 years of age. The angular changes generally are a delayed finding noticed in stance. The bowleg may be associated with marked tibial torsion and picked up early but the Blount's patient has been traditionally definable at 2 years of age. Levin and Drennan may hasten the time of diagnosis with their radiographic criteria. Knock-knee is an alignment disturbance noticed during the early to mid-childhood years, age 4 to 8 years. The diagnosis is important, differentiating physiologic from torsion-related deformities, and treatment, if warranted, should not be delayed. Generally the earlier these problems are discovered, the more optimistic the prognosis. Since the pediatric limb is in a constant state of transition, there will be a perpetual argument as to the need or efficacy of various approaches to the problems of knock-knee and bowleg. If observation is the treatment of choice, the percentage of cases which go on to osteotomies and epiphyseal stapling will continue. For those with axial or angular deformities, degenerative arthritis of the knee may be forthcoming. Swanson, Greene, and Allis warned of problems becoming "unphysiologic." If we consider the epiphyseal malleability, not only to deformity but to correction, we can appreciate Lenoir's comment of "every day the problem goes untreated is a golden

  6. In vivo visualization of photoreceptor layer and lipofuscin accumulation in Stargardt’s disease and fundus flavimaculatus by high resolution spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Giuseppe Querques

    2009-12-01

    Full Text Available Giuseppe Querques, Rosy Prato, Gabriel Coscas, Gisèle Soubrane, Eric H SouiedDepartment of Ophthalmology, Hopital Intercommunal de Creteil, University Paris XII, FranceIntroduction: To assess photoreceptor (PR layer morphology in patients with Stargardt’s disease (STGD and fundus flavimaculatus (FFM using high resolution spectral domain optical coherence tomography (HD-OCT; OCT 4000 Cirrus, Humphrey-Zeiss, San Leandro, CA.Methods: This was a prospective observational case series. Sixteen consecutive patients with STGD and FFM underwent a complete ophthalmologic examination. Optical coherence tomography examination was performed with HD-OCT, a high-speed (27,000 axial scans per second OCT system using spectral/Fourier domain detection, with an axial image resolution of 5 µm.Results: A total of 31 eyes were included in the study. Transverse loss of the PR layer in the foveal region was shown by HD-OCT. Twenty eyes with clinically evident central atrophy had a disruption of either the Verhoeff‘s membrane (VM or the layer corresponding to the interface of inner segment (IS and outer segment (OS of PR in the foveal region. Among these eyes, 12/20 eyes had a loss of the PR layer (loss of both VM and IS-OS interface in the foveal region. Eleven eyes (11/31 without clinically evident central atrophy had an intact interface of IS and OS of PR centrally. Moreover, we observed hyperreflective deposits: type 1 lesions located within the retinal pigment epithelium (RPE layer and at the level of the outer segments of PR, and type 2 lesions located at the level of the outer nuclear layer and clearly separated from the RPE layer. Type 1 lesions alone were associated with absence of loss of the PR layer in the foveal region in all eyes; type 2 lesions were always associated with presence of type 1 lesions, and often (8/12 eyes associated with loss of the PR layer within the foveal region. Mean best-corrected visual acuity (BCVA was significantly

  7. Axial 3D region of interest reconstruction using weighted cone beam BPF/DBPF algorithm cascaded with adequately oriented orthogonal butterfly filtering

    Science.gov (United States)

    Tang, Shaojie; Tang, Xiangyang

    2016-03-01

    Axial cone beam (CB) computed tomography (CT) reconstruction is still the most desirable in clinical applications. As the potential candidates with analytic form for the task, the back projection-filtration (BPF) and the derivative backprojection filtered (DBPF) algorithms, in which Hilbert filtering is the common algorithmic feature, are originally derived for exact helical and axial reconstruction from CB and fan beam projection data, respectively. These two algorithms have been heuristically extended for axial CB reconstruction via adoption of virtual PI-line segments. Unfortunately, however, streak artifacts are induced along the Hilbert filtering direction, since these algorithms are no longer accurate on the virtual PI-line segments. We have proposed to cascade the extended BPF/DBPF algorithm with orthogonal butterfly filtering for image reconstruction (namely axial CB-BPP/DBPF cascaded with orthogonal butterfly filtering), in which the orientation-specific artifacts caused by post-BP Hilbert transform can be eliminated, at a possible expense of losing the BPF/DBPF's capability of dealing with projection data truncation. Our preliminary results have shown that this is not the case in practice. Hence, in this work, we carry out an algorithmic analysis and experimental study to investigate the performance of the axial CB-BPP/DBPF cascaded with adequately oriented orthogonal butterfly filtering for three-dimensional (3D) reconstruction in region of interest (ROI).

  8. Análisis de la fuerza axial en un transportador de sinfín // Analysis of axial force in a screw conveyor.

    Directory of Open Access Journals (Sweden)

    F. Aguilar Parés

    1999-01-01

    Full Text Available Durante el movimiento de un material en un transportador de sinfín surge una fuerza en dirección axial que influye en laselección de uno de los cojinetes de apoyo del equipo. En el artículo aparecen algunas soluciones constructivas que tienen encuentan la fuerza axial. Por otro lado se establece la relación entre la fuerza axial y el empuje axial y se precisa de quiendepende el sentido del empuje axial. Por último se propone un modelo matemático que relaciona la fuerza axial con la potenciarequerida por el equipo.Palabras claves: Transportador de sinf in, fuerza axial , empuje axial ._________________________________________________________________________AbstractDuring the movement of material in a screw conveyor surge a force in axial direction that influence in the selection of one ofthe equipment support bearings. Some constructive solutions appear in the article for considering the axial force. In the otherhand it is established the relation between axial force and axial thurst and it is precised whose direction thurst axial depend of.Finally it is proposed a mathematic model that relates the axial force with the power required by the equipment.Key words: Screw conveyor, axial force, axial thurst .

  9. Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Segars, W. P., E-mail: paul.segars@duke.edu; Rybicki, K.; Norris, Hannah; Samei, E. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Frush, D. [Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States)

    2014-12-15

    Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r{sup 2} = 0.382, mean r{sup 2} = 0.236). Similar trends were found for organ midpoint versus height (max r{sup 2} = 0.439, mean r{sup 2} = 0.200) and for organ volume versus height (max r{sup 2} = 0.410, mean r{sup 2} = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r{sup 2}-values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r{sup 2} = 0.842, mean r{sup 2} = 0.790; max r{sup 2} = 0.949, mean r{sup 2} = 0.894; and max r{sup 2} = 0.870, mean r{sup 2} = 0.847, respectively). Moderate linear correlations were also observed for organ axial width

  10. The impact of degenerative spinal changes on the correlation of peripheral and axial bone density

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, P. (Klinik und Poliklinik fuer Nuklearmedizin, Wuerzburg Univ. (Germany)); Boerner, W. (Klinik und Poliklinik fuer Nuklearmedizin, Wuerzburg Univ. (Germany))

    1994-08-01

    Results of bone density measurements by quantitative computed tomography of the peripheral skeleton (pQCT) were compared with those of measurements at the axial skeleton with a view to study the effects of degenerative spinal changes on the validity of bone densitometry of the lumbar spine. 556 consecutive patients were examined by dual-energy X-ray absorptiometry (DXA) of the spine and by peripheral quantitative computed tomography (pQCT) of the distal radius. There were significant differences between the bone mineral values at the distal radius and those at the spine, depending on the degree of spinal degeneration. As expected, spinal degenerations showed a highly significant age dependence. With increasing degeneration the correlations between the radius total bone mineral concentration and the bone density of the lumbar spine decreased from r=0.45 to 0.23 in women and from r=0.64 to 0.28 in men. We conclude that the value of spinal DXA is reduced in patients with degenerative spinal disease, compared to the pQCT at the peripheral skeleton. (orig.)

  11. Neutron tomography for void distribution measurements

    International Nuclear Information System (INIS)

    Neutron tomography has previously been performed using large, stationary neutron sources such as reactors and spallation sources for applications where the object under study can be transported to the source. This paper accounts for the challenges met when applying neutron tomography using a portable accelerator driven neutron generator, which is required when studying non-transportable objects. In general, portable sources offer significantly lower neutron yields than stationary sources, implying the need for either longer measurement times or highly efficient measurement and/or analysis procedures. The particular application investigated here is the mapping of steam distributions in water (void distribution), which is of high importance for the performance of nuclear fuel assemblies in boiling water reactors (BWR). The void distribution cannot be measured directly in a reactor core, so instead various electrically-heated thermal-hydraulic test loops are used. In these loops, void correlations can be determined in full-size fuel assembly models, such as FRIGG in Sweden and DESIRE in Holland, but measurements are also performed in smaller, less complicated geometries. Previously, gamma tomography has been used to measure the void distribution in the FRIGG loop. However, improved capabilities to map the void distribution can be expected using neutrons because of their higher sensitivity to water relative to metal structures, as compared to gamma rays. At the same time, neutrons as probe also give rise to some challenges, such as high background from scattering. This paper investigates the possibility to use neutron tomography at axially symmetric objects such as the HWAT test loop in Sweden, where an annular two-phase flow of water/void is confined and heated by a steel cylinder. Monte Carlo simulations of the HWAT geometry and a suggested measurement setup have been carried out, using the particle transport code MCNPX. A reconstruction technique which exploits the

  12. An update on biomarkers in axial spondyloarthritis.

    Science.gov (United States)

    Prajzlerová, Klára; Grobelná, Kristýna; Pavelka, Karel; Šenolt, Ladislav; Filková, Mária

    2016-06-01

    Axial spondyloarthritis is a chronic inflammatory disease with the onset at a young age, and, if undiagnosed and untreated, it may result in permanent damage and lifelong disability. Rates of early diagnosis have improved, due in particular to the addition of magnetic resonance imaging into the diagnostic armamentaria; however, it is costly, not widely available, and requires experienced readers to interpret the findings. In addition to clinical measures and imaging techniques, biomarkers that will be described in this review may represent useful tools for diagnosis, monitoring disease activity and outcomes as well as therapeutic responses. Currently, HLA-B27 remains the best genetic biomarker for making a diagnosis, while CRP currently appears to be the best circulating measure for assessing disease activity, predicting structural progression and therapeutic response. Interestingly, key molecules in the pathogenesis of the disease and essential therapeutic targets, such as tumour necrosis factor (TNF)α, interleukin (IL)-17 and IL-23, show only limited association with disease characteristics or disease progression. Some genetic biomarkers and particularly anti-CD74 antibodies, may become a promising tool for the early diagnosis of axSpA. Further biomarkers, such as matrix metalloproteinases (MMP)-3, calprotectin (S100A8/9), vascular endothelial growth factor (VEGF), C-terminal telopeptide of type II collagen (CTX-II) or dickkopf-1 (DKK-1), are not sufficient to reflect disease activity, but may predict spinal structural progression. In addition, recent data have shown that monitoring calprotectin might represent a valuable biomarker of therapeutic response. However, all of these results need to be confirmed in large cohort studies prior to use in daily clinical practice. PMID:26851549

  13. Ultrasonic reflection tomography vs. canonical body approximation: experimental assessment of an infinite elastic cylindrical tube

    OpenAIRE

    Lasaygues, Philippe; Le Marrec, Loïc

    2008-01-01

    Comparisons were made between the results obtained using two quantitative ultrasound imaging methods on the solid cross section of a cylindrical tube that is infinite in the axial direction. The first method tested was the classical reflection tomography method based on the first-order Born approximation, which can only be used under conditions to obtain limited reconstruction of the external bound aries of the high contrast scatterer. The results were compared with those obtained using anoth...

  14. Direct coronal computed tomography of the lumbar spine: A new technical approach in supine position

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, P.; Uske, A.; Mansouri, B.

    1986-11-01

    Computed tomography (CT) was carried out on 46 subjects with L5-S1 disk hernia. All the patients had a L5-S1 angle equal or greater than 40 degrees. Coronal sections of the disk were obtained with a rostral angulation of the gantry, having placed the lumbar spin in a hyperlordotic position. Results are discussed and compared with those obtained from para-axial transverse sections and multidirectional reformated images.

  15. EDITORIAL: Industrial Process Tomography

    Science.gov (United States)

    West, Robert M.

    2004-07-01

    Industrial process tomography remains a multidisciplinary field with considerable interest for many varied participants. Indeed this adds greatly to its appeal. It is a pleasure and a privilege to once again act as guest editor for a special feature issue of Measurement Science and Technology on industrial process tomography, the last being in December 2002. Those involved in the subject appreciate the efforts of Measurement Science and Technology in producing another issue and I thank the journal on their behalf. It can be seen that there are considerable differences in the composition of material covered in this issue compared with previous publications. The dominance of electrical impedance and electrical capacitance techniques is reduced and there is increased emphasis on general utility of tomographic methods. This is encompassed in the papers of Hoyle and Jia (visualization) and Dierick et al (Octopus). Electrical capacitance tomography has been a core modality for industrial applications. This issue includes new work in two very interesting aspects of image reconstruction: pattern matching (Takei and Saito) and simulated annealing (Ortiz-Aleman et al). It is important to take advantage of knowledge of the process such as the presence of only two components, and then to have robust reconstruction methods provided by pattern matching and by simulated annealing. Although crude reconstruction methods such as approximation by linear back projection were utilized for initial work on electrical impedance tomography, the techniques published here are much more advanced. The paper by Kim et al includes modelling of a two-component system permitting an adaption-related approach; the paper by Tossavainen et al models free surface boundaries to enable the estimation of shapes of objects within the target. There are clear improvements on the previous crude and blurred reconstructions where boundaries were merely inferred rather than estimated as in these new developments

  16. Correction of distortions in optical coherence tomography imaging of the eye

    Energy Technology Data Exchange (ETDEWEB)

    Podoleanu, Adrian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Charalambous, Ismini [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Plesea, Lucian [Applied Optics Group, University of Kent, Canterbury (United Kingdom); Dogariu, Aristide [School of Optics, CREOL, University of Central Florida, Orlando, FL (United States); Rosen, Richard [Advanced Retinal Imaging Center, New York Eye and Ear Infirmary, NY (United States)

    2004-04-07

    Optical coherence tomography (OCT) images are affected by artefacts. These artefacts are the result of different factors such as refraction, curvature of the intermediate layers up to the depth of interest and the scanning procedure. The effect of such errors is different, depending on the way the image is acquired, either en-face or longitudinal OCT. We quantify the distortions by evaluating a lateral and an axial error. These measure the lateral and axial deviations of each image point from the object point inside the tissue. We show that the axial distortion can be larger than the achievable depth resolution in modern OCT systems. We have investigated these errors in imaging different tissue: cornea and retina in vivo and an intraocular lens in vitro.

  17. Dynamic Analysis of Axial Magnetic Forces for DVD Spindle Motors

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The axial magnetic force, induced by the complicated flux linkage distribution from rotor magnet and stator slotted, is constructed by different relative heights and calculated by 3D finite element method (FEM) to analyze the dynamic characteristics for a DVD spindle motor. The axial magnetic force is designed to provide an axial stiffness and govern the natural frequency of the dynamic performance. According to the simulation results and experimental measurements, the dynamic behaviors are significantly improved with a variation of relative height of rotor magnet and stator slotted on a DVD spindle motor.

  18. Gravitational waves from the axial perturbations of hyperon stars

    Institute of Scientific and Technical Information of China (English)

    Wen De-Hua; Yan Jing; Liu Xue-Mei

    2012-01-01

    The eigen-frequencies of the axial w-mode oscillations of hyperon stars are examined.It is shown that as the appearance of hyperons softens the equation of state of the super-density matter,the frequency of gravitational waves from the axial w-mode of hyperon star becomes smaller than that of a traditional neutron star at the same stellar mass.Moreover,the eigenfrequencies of hyperon stars also have scaling universality.It is shown that the EURO thirdgeneration gravitational-wave detector has the potential to detect the gravitational-wave signal emitted from the axial w-mode oscillations of a hyperon star.

  19. Tensile Property of Bi-axial Warp Knitted Structure

    Institute of Scientific and Technical Information of China (English)

    沈为

    2003-01-01

    The tensile property of bi-axial warp knitted fabrics is tested and compared with that of the plain weave fabric. The results show that there are obvious differences between the tensile property of a bi-axial warp knitted fabric and that of a plain weave fabric.The former can give fuller play to the property of a high modulus yarn than the latter. The tensile strength of a bi-axial warp knitted fabric is linear with the number of yarns in the direction of force.

  20. The axial charges of the hidden-charm pentaquark states

    CERN Document Server

    Wang, Guang-Juan; Zhu, Shi-Lin

    2016-01-01

    With the chiral quark model, we have calculated the axial charges of the pentaquark states with $(I,I_3)=(\\frac{1}{2},\\frac{1}{2})$ and $J^{P}=\\frac{1}{2}^{\\pm},\\frac{3}{2}^{\\pm},\\frac{5}{2}^{\\pm}$. The $P_c$ states with the same $J^P$ quantum numbers but different color-spin-flavor configurations have very different axial charges, which encode important information on their underlying structures. For some of the $J^{P}=\\frac{3}{2}^{\\pm}$ or $\\frac{5}{2}^{\\pm}$ pentaquark states, their axial charges are much smaller than that of the proton.

  1. A non-integral, axial-force measuring element

    Science.gov (United States)

    Ringel, M.; Levin, D.; Seginer, A.

    1989-10-01

    A new approach to the measurement of the axial force is presented. A nonintegral axial-force measuring element, housed within the wind-tunnel model, avoids the interactions that are caused by nonlinear elastic phenomena characteristic of integral balances. The new design overcomes other problems, such as friction, misalignment and relative motion between metric elements, that plagued previous attempts at separate measurement of the axial force. Calibration and test results prove the ability of the new approach to duplicate and even surpass the results of much more complicated and expensive integral balances. The advantages of the new design make it the best known solution for particular measurement problems.

  2. Effects of external axial magnetic field on fast electron propagation

    International Nuclear Information System (INIS)

    A scheme employing an external axial magnetic field is proposed to diagnose the intrinsic divergence of laser-generated fast electron beams, and this is studied numerically with hybrid simulations. The maximum beam radius of fast electrons increases with the initial divergence and decreases with the amplitude of the axial magnetic field. It is indicated that the intrinsic divergence of fast electrons can be inferred from measurements of the beam radius at different depth under the axial field. The proposed scheme here may be useful for future fast ignition experiments and in other applications of laser-generated fast electron beams.

  3. [Pneumothorax revealed by postoperative computed tomography].

    Science.gov (United States)

    Ikeda, Shizuka; Katori, Kiyoshi; Fujimoto, Minoru; Nitahara, Keiichi; Higa, Kazuo

    2005-11-01

    We report a case of pneumothorax revealed by postoperative computed tomography. A 39-year-old obese woman (height 153 cm, weight 70 kg) with fractures of the radius, ulna, clavicle, and femur in a traffic accident, was scheduled for osteosynthesis. Anesthesia was induced with thiopental and maintained with 50% nitrous oxide in oxygen and sevoflurane. The Spo2 decreased from 99% to 94% during the surgery. Bilateral chest sounds were symmetrical. The Spo2 increased to 100% after discontinuation of nitrous oxide. Pneumothorax was not evident on a postoperative chest X-ray, but computed tomography of the chest demonstrated right-sided pneumothorax. An ECG electrode had overlapped the fractured rib on the preoperative chest X-ray.

  4. Nanometer resolution optical coherence tomography using broad bandwidth XUV and soft x-ray radiation.

    Science.gov (United States)

    Fuchs, Silvio; Rödel, Christian; Blinne, Alexander; Zastrau, Ulf; Wünsche, Martin; Hilbert, Vinzenz; Glaser, Leif; Viefhaus, Jens; Frumker, Eugene; Corkum, Paul; Förster, Eckhart; Paulus, Gerhard G

    2016-01-01

    Optical coherence tomography (OCT) is a non-invasive technique for cross-sectional imaging. It is particularly advantageous for applications where conventional microscopy is not able to image deeper layers of samples in a reasonable time, e.g. in fast moving, deeper lying structures. However, at infrared and optical wavelengths, which are commonly used, the axial resolution of OCT is limited to about 1 μm, even if the bandwidth of the light covers a wide spectral range. Here, we present extreme ultraviolet coherence tomography (XCT) and thus introduce a new technique for non-invasive cross-sectional imaging of nanometer structures. XCT exploits the nanometerscale coherence lengths corresponding to the spectral transmission windows of, e.g., silicon samples. The axial resolution of coherence tomography is thus improved from micrometers to a few nanometers. Tomographic imaging with an axial resolution better than 18 nm is demonstrated for layer-type nanostructures buried in a silicon substrate. Using wavelengths in the water transmission window, nanometer-scale layers of platinum are retrieved with a resolution better than 8 nm. XCT as a nondestructive method for sub-surface tomographic imaging holds promise for several applications in semiconductor metrology and imaging in the water window. PMID:26860894

  5. Nanometer resolution optical coherence tomography using broad bandwidth XUV and soft x-ray radiation

    Science.gov (United States)

    Fuchs, Silvio; Rödel, Christian; Blinne, Alexander; Zastrau, Ulf; Wünsche, Martin; Hilbert, Vinzenz; Glaser, Leif; Viefhaus, Jens; Frumker, Eugene; Corkum, Paul; Förster, Eckhart; Paulus, Gerhard G.

    2016-02-01

    Optical coherence tomography (OCT) is a non-invasive technique for cross-sectional imaging. It is particularly advantageous for applications where conventional microscopy is not able to image deeper layers of samples in a reasonable time, e.g. in fast moving, deeper lying structures. However, at infrared and optical wavelengths, which are commonly used, the axial resolution of OCT is limited to about 1 μm, even if the bandwidth of the light covers a wide spectral range. Here, we present extreme ultraviolet coherence tomography (XCT) and thus introduce a new technique for non-invasive cross-sectional imaging of nanometer structures. XCT exploits the nanometerscale coherence lengths corresponding to the spectral transmission windows of, e.g., silicon samples. The axial resolution of coherence tomography is thus improved from micrometers to a few nanometers. Tomographic imaging with an axial resolution better than 18 nm is demonstrated for layer-type nanostructures buried in a silicon substrate. Using wavelengths in the water transmission window, nanometer-scale layers of platinum are retrieved with a resolution better than 8 nm. XCT as a nondestructive method for sub-surface tomographic imaging holds promise for several applications in semiconductor metrology and imaging in the water window.

  6. Osteolytic extra-axial sacral myxopapillary ependymoma

    Energy Technology Data Exchange (ETDEWEB)

    Biagini, R.; Demitri, S.; Orsini, U. [Clinica Ortopedica, Istituto Ortopedico Rizzoli, Bologna (Italy); Bibiloni, J. [Medical Sciences Campus San Juan, University of Puerto Rico (Puerto Rico); Briccoli, A. [Istituto di Patologia Chirurgica, University of Modena (Italy); Bertoni, F. [Servizio di Anatomia Patologica, Istituto Ortopedico Rizzoli Bologna (Italy)

    1999-10-01

    The authors report an unusual case of sacral osteolytic myxopapillary ependymoma treated with curettage and radiotherapy. There is no evidence of recurrence 8 years after treatment. A review of the literature is presented on sacral ependymomas presenting with an osteolytic radiographic appearance (24 cases in 18 reports). The differential diagnosis with other sacral neoplasms is discussed. (orig.)

  7. Neutron beam tomography software

    International Nuclear Information System (INIS)

    When a sample is traversed by a neutron beam, inhomogeneities in the sample will cause deflections, and the deflections will permit conclusions to be drawn concerning the location and size of the inhomogeneities. The associated computation is similar to problems in tomography, analogous to X-ray tomography though significantly different in detail. We do not have any point-sample information, but only mean values over short line segments. Since each mean value is derived from a separate neutron counter, the quantity of available data has to be modest; also, since each datum is an integral, its geometric precision is inferior to that of X-ray data. Our software is designed to cope with these difficulties. (orig.)

  8. Mathematical Methods in Tomography

    CERN Document Server

    Louis, Alfred; Natterer, Frank

    1991-01-01

    The conference was devoted to the discussion of present and future techniques in medical imaging, including 3D x-ray CT, ultrasound and diffraction tomography, and biomagnetic ima- ging. The mathematical models, their theoretical aspects and the development of algorithms were treated. The proceedings contains surveys on reconstruction in inverse obstacle scat- tering, inversion in 3D, and constrained least squares pro- blems.Research papers include besides the mentioned imaging techniques presentations on image reconstruction in Hilbert spaces, singular value decompositions, 3D cone beam recon- struction, diffuse tomography, regularization of ill-posed problems, evaluation reconstruction algorithms and applica- tions in non-medical fields. Contents: Theoretical Aspects: J.Boman: Helgason' s support theorem for Radon transforms-a newproof and a generalization -P.Maass: Singular value de- compositions for Radon transforms- W.R.Madych: Image recon- struction in Hilbert space -R.G.Mukhometov: A problem of in- teg...

  9. Controllable tomography phase microscopy

    Science.gov (United States)

    Xiu, Peng; Zhou, Xin; Kuang, Cuifang; Xu, Yingke; Liu, Xu

    2015-03-01

    Tomography phase microscopy (TPM) is a new microscopic method that can quantitatively yield the volumetric 3D distribution of a sample's refractive index (RI), which is significant for cell biology research. In this paper, a controllable TPM system is introduced. In this system a circulatory phase-shifting method and piezoelectric ceramic are used which enable the TPM system to record the 3D RI distribution at a more controllable speed, from 1 to 40 fps, than in the other TPM systems reported. The resolution of the RI distribution obtained by this controllable TPM is much better than that in images recorded by phase contrast microscopy and interference tomography microscopy. The realization of controllable TPM not only allows for the application of TPM to the measurement of kinds of RI sample, but also contributes to academic and technological support for the practical use of TPM.

  10. Polarised light sheet tomography.

    Science.gov (United States)

    Reidt, Sascha L; O'Brien, Daniel J; Wood, Kenneth; MacDonald, Michael P

    2016-05-16

    The various benefits of light sheet microscopy have made it a widely used modality for capturing three-dimensional images. It is mostly used for fluorescence imaging, but recently another technique called light sheet tomography solely relying on scattering was presented. The method was successfully applied to imaging of plant roots in transparent soil, but is limited when it comes to more turbid samples. This study presents a polarised light sheet tomography system and its advantages when imaging in highly scattering turbid media. The experimental configuration is guided by Monte Carlo radiation transfer methods, which model the propagation of a polarised light sheet in the sample. Images of both reflecting and absorbing phantoms in a complex collagenous matrix were acquired, and the results for different polarisation configurations are compared. Focus scanning methods were then used to reduce noise and produce three-dimensional reconstructions of absorbing targets. PMID:27409945

  11. Positron-emission tomography

    International Nuclear Information System (INIS)

    Positron-emission tomography (PET) combines early biochemical assessment of pathology achieved by nuclear medicine with the precise localization achieved by computerized image reconstruction. In this technique a chemical compound with the desired biological activity is labeled with a radioactive isotope that decays by emitting a positron, or positive electron. With suitable interpretation PET images can provide a noninvasive, regional assessment of many biochemical processes that are essential to the functioning of the organ that is being visualized

  12. Tutorial on photoacoustic tomography.

    Science.gov (United States)

    Zhou, Yong; Yao, Junjie; Wang, Lihong V

    2016-06-01

    Photoacoustic tomography (PAT) has become one of the fastest growing fields in biomedical optics. Unlike pure optical imaging, such as confocal microscopy and two-photon microscopy, PAT employs acoustic detection to image optical absorption contrast with high-resolution deep into scattering tissue. So far, PAT has been widely used for multiscale anatomical, functional, and molecular imaging of biological tissues. We focus on PAT’s basic principles, major implementations, imaging contrasts, and recent applications. PMID:27086868

  13. Reference structure tomography

    Science.gov (United States)

    Brady, David J.; Pitsianis, Nikos P.; Sun, Xiaobai

    2004-07-01

    Reference structure tomography (RST) uses multidimensional modulations to encode mappings between radiating objects and measurements. RST may be used to image source-density distributions, estimate source parameters, or classify sources. The RST paradigm permits scan-free multidimensional imaging, data-efficient and computation-efficient source analysis, and direct abstraction of physical features. We introduce the basic concepts of RST and illustrate the use of RST for multidimensional imaging based on a geometric radiation model.

  14. Compton tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Grubsky, Victor; Romanoov, Volodymyr; Shoemaker, Keith; Patton, Edward Matthew; Jannson, Tomasz

    2016-02-02

    A Compton tomography system comprises an x-ray source configured to produce a planar x-ray beam. The beam irradiates a slice of an object to be imaged, producing Compton-scattered x-rays. The Compton-scattered x-rays are imaged by an x-ray camera. Translation of the object with respect to the source and camera or vice versa allows three-dimensional object imaging.

  15. Investigation on centrifugal impeller in an axial-radial combined compressor with inlet distortion

    Science.gov (United States)

    Li, Du; Yang, Ce; Zhao, Ben; Zhou, Mi; Qi, Mingxu; Zhang, Jizhong

    2011-12-01

    Assembling an axial rotor and a stator at centrifugal compressor upstream to build an axial-radial combined compressor could achieve high pressure ratio and efficiency by appropriate size augment. Then upstream potential flow and wake effect appear at centrifugal impeller inlet. In this paper, the axial-radial compressor is unsteadily simulated by three-dimensional Reynolds averaged Navier-Stokes equations with uniform and circumferential distorted total pressure inlet condition to investigate upstream effect on radial rotor. The results show that span-wise nonuniform total pressure distribution is generated and radial and circumferential combined distortion is formed at centrifugal rotor inlet. The upstream stator wake deflects to rotor rotation direction and decreases with blade span increases. Circumferential distortion causes different separated flow formations at different pitch positions. The tip leakage vortex is suppressed in centrifugal blade passages. Under distorted inlet condition, flow direction of centrifugal impeller leading edge upstream varies evidently near hub and shroud but varies slightly at mid-span. In addition, compressor stage inlet distortion produces remarkable effect on blade loading of centrifugal blade both along chordwise and pitchwise.

  16. Uniform versus Nonuniform Axial Power Distribution in Rod Bundle CHF Experiments

    Directory of Open Access Journals (Sweden)

    Baowen Yang

    2014-01-01

    Full Text Available Rod bundle experiments with axially uniform and nonuniform heat fluxes are examined to explore the potential limitations of using uniform rod bundle CHF data for CHF correlation development of light water reactors with nonuniform axial power distribution (APD. The case of upstream burnout is presented as an example of unique phenomena associated with nonuniform rod bundle CHF experiments. It is a result from combined effect of axial nonuniform power shape and different interchannel mixing mechanisms. In addition, several key parameters are investigated with respect to their potential impacts on the thermal-hydraulic behaviors between rod bundles with uniform and nonuniform APDs. This type of misrepresentation cannot be amended or compensated through the use of correction factors due to the lack of critical information in the uniform rod bundle CHF testing as well as the fundamental difference in the underlining driving mechanisms. Other potential issues involved with the use of uniform rod bundle CHF data for nonuniform APD system applications also present strong evidence concerning the limitations and inadequacy of using uniform rod bundle CHF data for the correlation, prediction, and design limit calculation for safety analysis.

  17. ANALYSIS OF PULSATILE BLOOD FLOW IN AXIALLY MOVING ARTERIES

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In order to study motional properties of pulsatile blood flow in axially moving arteries, the authors derived some expressions of the pulsatile blood flow from the basic equations of motion for blood and vascular walls, including an axial blood velocity equation, a flow rate equation and a wall shear stress equation, which described not only the overall axial movement of the arteries but also the elastic properties of the vascular walls, discussed the effects of the arterial wall elasticity on the wall shear stress in coronary arteries in terms of these expressions, and analyzed changes of motional properties of pulsatile blood flow between an elastic arterial tube model and a rigid tube model. The results proved the inference by J.E. Moore Jr. et al. (1994) that the axial movement of arteries be as important in determining coronary artery hemodynamics as the elastic property of the vascular wall.

  18. Effect of axial heat flux distribution on CHF

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol

    2000-10-01

    Previous investigations for the effect of axial heat flux distributions on CHF and the prediction methods are reviewed and summarized. A total of 856 CHF data in a tube with a non-uniform axial heat flux distribution has been compiled from the articles and analyzed using the 1995 Groeneveld look-up table. The results showed that two representative correction factors, K5 of the look-up table and Tongs F factor, can be applied to describe the axial heat flux distribution effect on CHF. However, they overpredict slightly the measured CHF, depending on the quality and flux peak shape. Hence, a corrected K5 factor, which accounts for the axial heat flux distribution effect is suggested to correct these trends. It predicted the CHF power for the compiled data with an average error of 1.5% and a standard deviation of 10.3%, and also provides a reasonable prediction of CHF locations.

  19. Axial Stringy System of the Kerr Spinning Particle

    CERN Document Server

    Burinskii, A

    2004-01-01

    The structure of classical spinning particle based on the Kerr-Newman black hole (BH) solution is investigated. For large angular momentum, $|a|>>m$, the BH horizons disappear exposing a naked ringlike source which is a circular relativistic string. It was shown recently that electromagnetic excitations of this string lead to the appearance of an extra axial stringy system which consists of two half-infinite strings of opposite chirality. In this paper we consider the relation of this stringy system to the Dirac equation. We also show that the axial strings are the Witten superconducting strings and describe their structure by the Higgs field model where the Higgs condensate is used to regularize axial singularity. We argue that this axial stringy system may play the role of a classical carrier of the wave function.

  20. Polychromatic diffraction contrast tomography

    International Nuclear Information System (INIS)

    This tutorial review introduces the use of polychromatic radiation for 3D grain mapping using X-ray diffraction contrast tomography. The objective is to produce a 3D map of the grain shapes and orientations within a bulk, millimeter-sized polycrystalline sample. The use of polychromatic radiation enables the standard synchrotron X-ray technique to be applied in a wider range of contexts: 1) Using laboratory X-ray sources allows a much wider application of the diffraction contrast tomography technique. 2) Neutron sources allow large samples, or samples containing high Z elements to be studied. 3) Applied to synchrotron sources, smaller samples may be treated, or faster measurements may be possible. Challenges and particularities in the data acquisition and processing, and the limitations of the different variants, are discussed. - Highlights: • We present a tutorial review of polychromatic diffraction contrast tomography techniques. • The use of polychromatic radiation allows the standard synchrotron DCT technique to be extended to a range of other sources. • The characteristics and limitations of all variants of the techniques are derived, discussed and compared. • Examples using laboratory X-ray and cold neutron radiation are presented. • Suggestions for the future development of these techniques are presented

  1. Tomography with thermal neutrons

    International Nuclear Information System (INIS)

    This paper describes some tomographic measurements performed with thermal neutrons at the Instituto de Engenharia Nuclear - IEN/CNEN. The Argonauta Reactor at this Institute was used as neutron source. During the measurements this reactor produced a 36 x 105 n.cm-1.s-1 thermal neutron flux at end of the irradiation channel, wherein the tomographic system was installed. An homogeneous aluminum cylindrical rod was used to calibrate the system and to determine parameters governing the quality of the images. The aluminum cross section emerging from the image reconstruction process, was then compared with the values found in the literature. To evaluate the capability of this technique as a complementary tool, to the X-ray tomography, images of a solid aluminum cylinder, wherein, several thin rods of different materials were inserted, were taken. These materials were chosen among elements with high atomic numbers, as well as, among elements having a Z close to each other. A tomographic image of a small electric motor, displayed several elements of its internal structure. The overall results have demonstrated the capability of the thermal neutron tomography to complement the X-ray tomography, specially for samples containing elements of high atomic numbers such as lead (Z=82), or elements having atomic numbers close to each other such as iron (Z=26) and copper (Z=29). (author)

  2. Polychromatic diffraction contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    King, A., E-mail: king@synchrotron-soleil.fr [Synchrotron SOLEIL, Gif-sur-Yvette 91192 (France); Reischig, P. [Xnovo Technology ApS, 4600 Køge (Denmark); Department of Materials Science and Engineering, Delft University of Technology, Delft 2628 CD (Netherlands); Adrien, J. [MATEIS, INSA de Lyon, Villeurbanne 69621 (France); Peetermans, S. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Ludwig, W. [MATEIS, INSA de Lyon, Villeurbanne 69621 (France); European Synchrotron Radiation Facility, Grenoble 38043 (France)

    2014-11-15

    This tutorial review introduces the use of polychromatic radiation for 3D grain mapping using X-ray diffraction contrast tomography. The objective is to produce a 3D map of the grain shapes and orientations within a bulk, millimeter-sized polycrystalline sample. The use of polychromatic radiation enables the standard synchrotron X-ray technique to be applied in a wider range of contexts: 1) Using laboratory X-ray sources allows a much wider application of the diffraction contrast tomography technique. 2) Neutron sources allow large samples, or samples containing high Z elements to be studied. 3) Applied to synchrotron sources, smaller samples may be treated, or faster measurements may be possible. Challenges and particularities in the data acquisition and processing, and the limitations of the different variants, are discussed. - Highlights: • We present a tutorial review of polychromatic diffraction contrast tomography techniques. • The use of polychromatic radiation allows the standard synchrotron DCT technique to be extended to a range of other sources. • The characteristics and limitations of all variants of the techniques are derived, discussed and compared. • Examples using laboratory X-ray and cold neutron radiation are presented. • Suggestions for the future development of these techniques are presented.

  3. Aerodynamics and combustion of axial swirlers

    Science.gov (United States)

    Fu, Yongqiang

    A multipoint lean direct injection (LDI) concept was introduced recently in non-premixed combustion to obtain both low NOx emissions and good combustion stability. In this concept, a key feature is the injection of finely atomized fuel into the high-swirling airflow at the combustor dome that provides a homogenous, lean fuel-air mixture. In order to achieve the fine atomization and mixing of the fuel and air quickly and uniformly, a good swirler design should be studied. The focus of this dissertation is to investigate the aerodynamics and combustion of the swirling flow field in a multipoint Lean Direct Injector combustor. A helical axial-vaned swirler with a short internal convergent-divergent venturi was used. Swirlers with various vane angles and fuel nozzle insertion lengths have been designed. Three non-dimensional parameter effects on non-reacting, swirling flow field were studied: swirler number, confinement ratio and Reynolds number. Spray and combustion characteristics on the single swirler were studied to understand the mechanism of fuel-air mixing in this special configuration. Multi-swirler interactions were studied by measuring the confined flow field of a multipoint swirler array with different configurations. Two different swirler arrangements were investigated experimentally, which include a co-swirling array and a counter-swirling array. In order to increase the range of stability of multipoint LDI combustors, an improved design were also conducted. The results show that the degree of swirl and the level of confinement have a clear impact on the mean and turbulent flow fields. The swirling flow fields may also change significantly with the addition of a variety of simulated fuel nozzle insertion lengths. The swirler with short insertion has the stronger swirling flow as compared with the long insertion swirler. Reynolds numbers, with range of current study, will not alter mean and turbulent properties of generated flows. The reaction of the spray

  4. PRELIMINARY DESIGN ANALYSIS OF AXIAL FLOW TURBINES

    Science.gov (United States)

    Glassman, A. J.

    1994-01-01

    A computer program has been developed for the preliminary design analysis of axial-flow turbines. Rapid approximate generalized procedures requiring minimum input are used to provide turbine overall geometry and performance adequate for screening studies. The computations are based on mean-diameter flow properties and a stage-average velocity diagram. Gas properties are assumed constant throughout the turbine. For any given turbine, all stages, except the first, are specified to have the same shape velocity diagram. The first stage differs only in the value of inlet flow angle. The velocity diagram shape depends upon the stage work factor value and the specified type of velocity diagram. Velocity diagrams can be specified as symmetrical, zero exit swirl, or impulse; or by inputting stage swirl split. Exit turning vanes can be included in the design. The 1991 update includes a generalized velocity diagram, a more flexible meanline path, a reheat model, a radial component of velocity, and a computation of free-vortex hub and tip velocity diagrams. Also, a loss-coefficient calibration was performed to provide recommended values for airbreathing engine turbines. Input design requirements include power or pressure ratio, mass flow rate, inlet temperature and pressure, and rotative speed. The design variables include inlet and exit diameters, stator angle or exit radius ratio, and number of stages. Gas properties are input as gas constant, specific heat ratio, and viscosity. The program output includes inlet and exit annulus dimensions, exit temperature and pressure, total and static efficiencies, flow angles, blading angles, and last stage absolute and relative Mach numbers. This program is written in FORTRAN 77 and can be ported to any computer with a standard FORTRAN compiler which supports NAMELIST. It was originally developed on an IBM 7000 series computer running VM and has been implemented on IBM PC computers and compatibles running MS-DOS under Lahey FORTRAN, and

  5. Nuclear Axial Currents in Chiral Effective Field Theory

    OpenAIRE

    Baroni, A.; Girlanda, L.; Pastore, S.; Schiavilla, R.; Viviani, M

    2015-01-01

    Two-nucleon axial charge and current operators are derived in chiral effective field theory up to one loop. The derivation is based on time-ordered perturbation theory, and accounts for cancellations between the contributions of irreducible diagrams and the contributions due to non-static corrections from energy denominators of reducible diagrams. Ultraviolet divergencies associated with the loop corrections are isolated in dimensional regularization. The resulting axial current is finite and...

  6. Design and Simulation of Axial Flow Maglev Blood Pump

    OpenAIRE

    Huachun Wu; Ziyan Wang; Xujun Lv

    2011-01-01

    The axial flow maglev blood pump (AFMBP) has become a global research focus and emphasis for artificial ventricular assist device, which has no mechanical contact, mechanical friction, compact structure and light weight, can effectively solve thrombus and hemolysis. Magnetic suspension and impeller is two of the important parts in the axial flow maglev blood pump, and their structure largely determines the blood pump performance. The research adopts electromagnetic and fluid finite element an...

  7. Axial Anomaly in Lattice Abelian Gauge Theory in Arbitrary Dimensions

    CERN Document Server

    Fujiwara, T; Wu, K; Fujiwara, Takanori; Suzuki, Hiroshi; Wu, Ke

    1999-01-01

    Axial anomaly of lattice abelian gauge theory in hyper-cubic regular lattice in arbitrary even dimensions is investigated by applying the method of exterior differential calculus. The topological invariance, gauge invariance and locality of the axial anomaly determine the explicit form of the topological part. The anomaly is obtained up to a multiplicative constant for finite lattice spacing and can be interpreted as the Chern character of the abelian lattice gauge theory.

  8. Volume Dependence of the Axial Charge of the Nucleon

    OpenAIRE

    Hall, N. L.; Thomas, A. W.; Young, R.D.(ARC Centre of Excellence for Particle Physics at the Terascale and CSSM, School of Chemistry and Physics, University of Adelaide, Adelaide, SA 5005, Australia); Zanotti, J. M.

    2012-01-01

    It is shown that the strong volume-dependence of the axial charge of the nucleon seen in lattice QCD calculations can be understood quantitatively in terms of the pion-induced interactions between neighbouring nucleons. The associated wave function renormalization leads to an increased suppression of the axial charge as the strength of the interaction increases, either because of a decrease in lattice size or in pion mass.

  9. Passive axial stabilization of a magnetic radial bearing by superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Marinescu, M.; Marinescu, N. (Ing.-Buro f. Magnettechnik, Mailander Str.19, D-6000 Frankfurt/M. 70 (DE)); Tenbrink, J.; Krauth, H. (Vacuumschmelze GmbH, Gruner Weg 37, D-6450 Hanau (DE))

    1989-09-01

    Contactless bearings for high-speed operation can be constructed using passive magnet systems, which inherently need a second, active bearing for their stabilization. Completely passive bearings only can be obtained using diamagnetic materials. This study deals with the axial stabilization of magnetic radial bearings using a permanent magnet/superconductor system. Using finite element calculation procedures it is shown that axial forces of up 3000 N and stiffnesses of up to 400 N/mm may be achieved.

  10. Testing of Axially Loaded Bucket Foundation with Applied Overburden Pressure

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    This report analyses laboratory testing data performed with a bucket foundation model subjected to axial loading. The examinations were conducted at the Geotechnical laboratory of Aalborg University. The report aims at showing and discussing the results of the static and cyclic axial loading tests...... on the bucket foundation model. Finally, a cyclic loading interaction diagram is given that can be applied for a full-scale bucket foundation design....

  11. Watson's theorem and the $N\\Delta(1232)$ axial transition

    CERN Document Server

    Alvarez-Ruso, L; Nieves, J; Vacas, M J Vicente

    2016-01-01

    We present a new determination of the $N\\Delta$ axial form factors from neutrino induced pion production data. For this purpose, the model of Hernandez et al., Phys. Rev. D76, 033005 (2007) is improved by partially restoring unitarity. This is accomplished by imposing Watson's theorem on the dominant vector and axial multipoles. As a consequence, a larger $C_5^A(0)$, in good agreement with the prediction from the off-diagonal Goldberger-Treiman relation, is now obtained.

  12. Axial Non-linear Dynamic Soil-Pile Interaction - Keynote

    OpenAIRE

    Holeyman A.; Whenham V.

    2014-01-01

    This keynote lecture describes recent analytical and numerical advances in the modeling of the axial nonlinear dynamic interaction between a single pile and its embedding soil. On one hand, analytical solutions are developed for assessing the nonlinear axial dynamic response of the shaft of a pile subjected to dynamic loads, and in particular to vibratory loads. Radial inhomogeneity arising from shear modulus degradation is evaluated over a range of parameters and compared with those obtained...

  13. Particle simulation of an improved axially extracted vircator

    International Nuclear Information System (INIS)

    An axially extracted virtual cathode oscillator (vircator) with a feedback annulus is proposed and configured through particle-in-cell (PIC) simulation. In this paper, the effects of the feedback mechanism are studied through PIC method. The simulated results indicate that the improved new vircator can increase the output power twice large than that of the axially-extracted conventional vircator under the same condition. On the other hand, it can narrow the bandwidth and purify the modes

  14. Particle Simulation of an Improved Axially Extracted Vircator

    Institute of Scientific and Technical Information of China (English)

    刘振祥; 舒挺; 张建德; 钱宝良

    2003-01-01

    An axially extracted virtual cathode oscillator (vircator) with a feedback annulusis proposed and configured through particle-in-cell (PIC) simulation in Ref. [1]. In this paper,the effects of the feedback mechanism are studied through PIC method. The simulated resultsindicate that the improved new vircator can increase the output power twice large than that ofthe axially-extracted conventional vircator under the same condition. On the other hand, it cannarrow the bandwidth and purify the modes.

  15. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  16. Axial Myopia and its Influence on Diabetic Retinopathy

    International Nuclear Information System (INIS)

    Objective: To evaluate the correlation between axial myopia and diabetic retinopathy. Study Design: Cross-sectional study. Place and Duration of Study: Eye Department of Postgraduate Medical Institute, Lahore General Hospital, from August 2012 to February 2013. Methodology: A total of 258 participants suffering from type-2 diabetic retinopathy were included. Axial length was measured by two optometrists using contact type ultrasound biometer. Colored retinal photographs, red free retinal photographs and Fundus Fluorescein Angiography (FFA) were performed on all patients using standard fundus camera. All fundus photographs and angiograms were independently reviewed and graded by two qualified vitreoretinal fellows. Results: Out of 258 patients, 163 were males (63.2%) and 95 (36.8%) were females. Average age of patients was 56.30 +- 7.57 years. Average axial length of right and left eyes were 23.16 mm and 23.15 mm respectively. There was statistically significant negative correlation between axial length and severity of diabetic retinopathy in the right eye, (Spearman correlation = -0.511, p = 0.0001) as well as the left eye (Spearman correlation = -0.522, p = 0.0001). Conclusion: There is a protective influence of longer axial length of globe on the stage and severity of diabetic retinopathy. This study may help in modifying the screening protocol for diabetic retinopathy amongst patients of differing axial lengths. (author)

  17. Axial blanket for 16NGF Angra 1 fuel type

    Energy Technology Data Exchange (ETDEWEB)

    Sadde, Luciano Martins; Faria, Eduardo Fernandes [Industrias Nucleares do Brasil (INB), Resende, RJ (Brazil)]. E-mails: sadde@inb.gov.br; faria@inb.gov.br; Sang-Keun You [Korea Nuclear Fuel Co. Ltd. (KNFC), Taejon (Korea, Republic of)]. E-mail: skyou@knfc.co.kr

    2007-07-01

    Angra-1, Kori-2 and Krsko are nuclear power plants with the same design. However, the fuel assemblies have some differences in design due to the countries strategies and the differences in the fabrication process. The 16NGF (16x16 Next Generation Fuel) was developed by INB, KNFC and Westinghouse in order to be used in these three nuclear power plants and the 'Axial Blanket' is one of the new features for the 16NGF design. The main purpose of the Axial Blanket Optimization study is to determine which axial blanket enrichment and length would provide the better fuel cycle cost benefit. All of the calculations were performed using Gadolinium as Burnable Absorber and solid pellets type for Axial Blanket. The results indicate 1.8 w/o U235 enrichment and 8 inches length as the best option of Axial Blanket from the fuel cycle cost benefit standpoint. The economy is about 1.8%. The difference in the reload cost in the range between 1.5 and 2.6 w/o U235 enrichment and for the 6 and 8 inches length is not so significant. Due that, from the Fq limit standpoint and also for longer cycle length requirements, a higher axial blanket enrichment (2.6 w/o) and shorter length (6 inches) is recommended. (author)

  18. Axial design of nuclear fuel using path relinking; Diseno axial de combustible nuclear utilizando path relinking

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, A.; Torres, M.; Ortiz, J. J.; Perusquia, R.; Hernandez, J. L.; Montes, J. L. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: jacm@nuclear.inin.mx

    2008-07-01

    In the present work the preliminary results were obtained with the zoctli system whose purpose is the axial design of assembly of nuclear fuel under certain considerations. For the mentioned design well-know cells were already used and that they have been proven in diverse cycles of operation in the nuclear power plant of Laguna Verde. The design contemplates fuels assemblies of 10x10 and with 2 water channels. The assembly was distributed in 6 axial zones according to its structure. In order to take to end the optimization is was used the well-known technique like Path relinking and to find the group of previous solutions required by this technique uses the technical Taboo search. In order to work with Path relinking, 5 trajectories was taken in to account from a set of 5 previous solutions generated with theTaboo search, the update of the group of solutions is carried out in dynamic form. In the case of the Taboo search it was used a list of variable size, it was implement an aspiration approach, it was used the vector of frequencies and due to the cost of the evaluation of the objective function, only it was review 5% of the vicinity. For the objective function was considered the limit thermal, the axial profile of power, the effective multiplication factor and the margin of having turned off in cold. In order to prove the design system, it was used a balance cycle with a value of reference of 0.9928 for the effective multiplication factor that is equivalent to a produced energy of 10896 MWd/TU at the end of operation to full power. The designed assemblies were placed both in one of lots different from fresh assemblies on which it counts the referred cycle. At the end one a comparison with the results obtained with other techniques and under similar conditions is made. The results obtained until the moment show an appropriate performance of the system. It is possible to indicate that a small inconvenient is the amount of consumed resources of calculation during

  19. Evolving "Diagnostic" Criteria for Axial Spondyloarthritis in the Context of Anterior Uveitis.

    Science.gov (United States)

    Rosenbaum, James T

    2016-08-01

    Anterior uveitis is far more common than intermediate, posterior or panuveitis. About 50% of patients with acute anterior uveitis are HLA B27+. Those who are HLA B27+ are highly likely to have associated back, joint, or tendon disease. The majority of patients with acute anterior uveitis and inflammatory low back pain are suffering from axial spondyloarthritis and radiographic evidence for abnormal sacroiliac joints is not required to make this diagnosis. Received 12 October 2015; revised 31 January 2016; accepted 16 February 2016; published online 12 April 2016. PMID:27070270

  20. Simultaneous measurement of cerebral blood flow and oxygen extraction fraction by positron emission tomography: theoretical study and experimental evidence of cerebral blood flow measurement with the C15O2 continuous inhalation technique

    International Nuclear Information System (INIS)

    The method of the continuous inhalation technique of oxygen-15 labelled CO2 coupled with positron emission tomography for the measurement of cerebral blood flow (C.B.F.) is described. An indirect experimental verification that this technique allowed the measurement of C.B.F. has been carried out in baboons by showing the expected change in the measured parameter with variations in the PaCO2. A critical investigation of the C15O2 model was performed. The amount of tracer present in the cerebral vascular pool has a negligible effect on C.B.F. value. The use of a mean brain-blood partition coefficient of water instead of that specific to gray or to white matter is commented upon, and its influence on the final C.B.F. value is studied. Lastly, the problem of the limited diffusion of water across the blood-brain-barrier is discussed. The study of the combined effects of gray-white mixing and limited wates extraction of the C.B.F. value shows that the C15O2 technique tends to understimate real C.B.F., and that this error is more severe with high flows and even gray white mixing. These limitations do not depart from the possibility to estimate in the same brain locus not only C.B.F. but oxygen utilization as well by the consecutive inhalation of C15O2 and 15O2. The advantages of this possibility has already been shown in a number of clinical studies

  1. Finite quantum tomography via semidefinite programming

    OpenAIRE

    Jafarizadeh, M. A.; Mirzaee, M.; Rezaee, M

    2007-01-01

    Using the the convex semidefinite programming method and superoperator formalism we obtain the finite quantum tomography of some mixed quantum states such as: qudit tomography, N-qubit tomography, phase tomography and coherent spin state tomography, where that obtained results are in agreement with those of References \\cite{schack,Pegg,Barnett,Buzek,Weigert}.

  2. Determination of Axial Length Requiring Adjustment of Measured Circumpapillary Retinal Nerve Fiber Layer Thickness for Ocular Magnification

    Science.gov (United States)

    Hirasawa, Kazunori; Shoji, Nobuyuki; Yoshii, Yukako; Haraguchi, Shota

    2014-01-01

    Purpose To determine the axial length requiring adjustment of measured circumpapillary retinal nerve fiber layer (cpRNFL) thickness to account for ocular magnification during spectral-domain optical coherence tomography (SD-OCT). Methods In this prospective study, 148 eyes of 148 healthy student volunteers were imaged by two examiners using three-dimensional SD-OCT. In 54 randomly selected eyes, total cpRNFL thickness was measured with and without adjustment for ocular magnification to establish intra-examiner and inter-examiner measurement error. The 148 eyes were then divided into three groups according to the error values: control group (difference in the corrected and uncorrected total cpRNFL thickness was within the measurement error range), thinner group (the corrected total cpRNFL thickness was less than the uncorrected one), and thicker group (the corrected total cpRNFL thickness was more than the uncorrected one). The cutoff values of axial length between the control and the other groups were calculated by receiver operating characteristic analysis. Results Measurement error ranged from 4.2 to 5.3 µm; the threshold value was defined as 5.3 µm. The cutoff values of axial length between the thinner and the control groups and between the control and the thicker groups were 23.60 (area under the curve [AUC] = 0.959) and 25.55 (AUC = 0.944) mm, respectively. Conclusions Axial lengths shorter than 23.60 mm and longer than 25.55 mm require adjustment of measured cpRNFL thickness to account for ocular magnification during SD-OCT. Clinical Trial Registration UMIN Clinical Trials Registry (http://www.umin.ac.jp/) under unique trial number UMIN000013248 (date of registration: 02/24/2014) PMID:25215521

  3. Analysis of acetabular version in the native hip: comparison between 2D axial CT and 3D CT measurements

    Energy Technology Data Exchange (ETDEWEB)

    Dandachli, Wael [Department of Orthopaedic Surgery, Imperial College London Hospitals, London (United Kingdom); Ul Islam, Saif; Tippett, Richard; Hall-Craggs, Margaret A.; Witt, Johan D. [University College London Hospitals, London (United Kingdom)

    2011-07-15

    To compare two-dimensional (2D) axial with three-dimensional (3D) computerized tomography (CT) measurements of acetabular version in native hips. CT scans of 34 hips in 17 consecutive patients being investigated for femoroacetabular impingement were analyzed. Acetabular version was measured using 2D CT at two different axial levels, one cranial (slice 2) and the other at the equator (slice 3). The measurements were repeated after correction for pelvic tilt. The results were compared to the measurements of anatomical version obtained using a 3D CT method that automatically corrects for pelvic tilt. The mean acetabular version using the 3D CT method was 15.7 (SD 6.9 ). The mean version using slice 2 was 9.3 (SD 6.5 ) before correction for pelvic tilt and 15.7 (SD 8.0 ) after the correction. The mean version using slice 3 was 16.4 (SD 4.2 ) before tilt correction and 19.0 (SD 5.0 ) after the correction. In relation to the 3D method, the intraclass correlation coefficient (ICC) was 0.58 for the uncorrected and 0.93 for the corrected slice 2 method. For the uncorrected and corrected slice 3 methods, the ICC was 0.64 and 0.89, respectively. The 2D axial methods produced variable results. The results that correlated best with the 3D method were those of the cranial slice (slice 2) after correction for pelvic tilt. Interpretation of 2D axial CT measurements of acetabular version should be done with caution. The level at which the measurement is done and the presence of pelvic tilt appear to be significant factors. (orig.)

  4. Computed Tomography Structural Lung Changes in Discordant Airflow Limitation

    NARCIS (Netherlands)

    F.A.A. Mohamed Hoesein (Firdaus); P.A. de Jong (Pim); J.W.J. Lammers; W.P. Mali (Willem); M. Schmidt (Michael); H.J. de Koning (Harry); C.M. van der Aalst (Carlijn); M. Oudkerk (Matthijs); R. Vliegenthart (Rozemarijn); B.T.J. van Ginneken (Berbke); E.M. van Rikxoort (Eva); P. Zanen (Pieter)

    2013-01-01

    textabstractBackground:There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping acco

  5. Computed tomography structural lung changes in discordant airflow obstruction

    NARCIS (Netherlands)

    Hoesein, F.A.A.M.; Jong, P.A. de; Lammers, J.W.; Mali, W.P.Th.; Schmidt, M.; Koning, H.J. de; Aalst, C. van der; Oudkerk, M.; Vliegenthart, R.; Ginneken, B. van; Rikxoort, E.M. van; Zanen, P.

    2013-01-01

    Background: There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to cl

  6. Computed Tomography Structural Lung Changes in Discordant Airflow Limitation

    OpenAIRE

    Firdaus A A Mohamed Hoesein; de Jong, Pim A; Lammers, Jan-Willem J; Willem Pthm Mali; Michael Schmidt; de Koning, Harry J.; Carlijn van der Aalst; Matthijs Oudkerk; Rozemarijn Vliegenthart; Bram van Ginneken; van Rikxoort, Eva M; Pieter Zanen

    2013-01-01

    BACKGROUND: There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to classification of airflow limitation (FEV1/FVC 70%; group 2LLN; and group 370% but FEV1

  7. Cork quality estimation by using Compton tomography

    CERN Document Server

    Brunetti, A; Golosio, B; Luciano, P; Ruggero, A

    2002-01-01

    The quality control of cork stoppers is mandatory in order to guarantee the perfect conservation of the wine. Several techniques have been developed but until now the quality control was essentially related to the status of the external surface. Thus possible cracks or holes inside the stopper will be hidden. In this paper a new technique based on X-ray Compton tomography is described. It is a non-destructive technique that allows one to reconstruct and visualize the cross-section of the cork stopper analyzed, and so to put in evidence the presence of internal imperfections. Some results are reported and compared with visual classification.

  8. Imaging actinic keratosis by high-definition optical coherence tomography. Histomorphologic correlation

    DEFF Research Database (Denmark)

    Boone, Marc A L M; Norrenberg, Sarah; Jemec, Gregor B E;

    2013-01-01

    transversal and axial directions, enable to visualize individual cells up to a depth of around 570 μm filling the imaging gap between conventional optical coherence tomography and reflectance confocal microscopy. We sought to determine the feasibility of detecting and grading of actinic keratosis...... by this technique using criteria defined for reflectance confocal microscopy compared to histology. In this pilot study, skin lesions of 17 patients with a histologically proven actinic keratosis were imaged by high-definition optical coherence tomography just before excision and images analysed qualitatively...... of photodamage. Using features already suggested by reflectance confocal microscopy, the study implies that high-definition optical coherence tomography facilitates in vivo diagnosis of actinic keratosis and allows the grading of different actinic keratosis lesions for increased clinical utility....

  9. Multiple scattering tomography.

    Science.gov (United States)

    Modregger, Peter; Kagias, Matias; Peter, Silvia; Abis, Matteo; Guzenko, Vitaliy A; David, Christian; Stampanoni, Marco

    2014-07-11

    Multiple scattering represents a challenge for numerous modern tomographic imaging techniques. In this Letter, we derive an appropriate line integral that allows for the tomographic reconstruction of angular resolved scattering distributions, even in the presence of multiple scattering. The line integral is applicable to a wide range of imaging techniques utilizing various kinds of probes. Here, we use x-ray grating interferometry to experimentally validate the framework and to demonstrate additional structural sensitivity, which exemplifies the impact of multiple scattering tomography. PMID:25062159

  10. Extended Diffraction Tomography

    CERN Document Server

    Schlottmann, R B

    2009-01-01

    We present the development of extended diffraction tomography, a new approach to the solution of the linear seismic waveform inversion problem. This method has several appealing features, such as the use of arbitrary depth-dependent reference models and the decomposition of the full 2D or 3D inverse problem into a large number of independent 1D problems. This decomposition makes the method naturally highly parallelizable. Careful implementation yields significant robustness with respect to noise. Several synthetic examples are shown which characterize the benefits of our method and demonstrate the usefulness of choosing realistic 1D reference media.

  11. DIY Tomography sample holder

    Science.gov (United States)

    Lari, L.; Wright, I.; Boyes, E. D.

    2015-10-01

    A very simple tomography sample holder at minimal cost was developed in-house. The holder is based on a JEOL single tilt fast exchange sample holder where its exchangeable tip was modified to allow high angle degree tilt. The shape of the tip was designed to retain mechanical stability while minimising the lateral size of the tip. The sample can be mounted on as for a standard 3mm Cu grids as well as semi-circular grids from FIB sample preparation. Applications of the holder on different sample systems are shown.

  12. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  13. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  14. Computed tomography device

    International Nuclear Information System (INIS)

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  15. Compressive Phase Contrast Tomography

    CERN Document Server

    Maia, F R N C; Marchesini, S; Padmore, H A; Parkinson, D Y; Pien, J; Schirotzek, A; Yang, C; 10.1117/12.861946

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. In- terference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher con- trast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  16. Radial reflection diffraction tomography

    Science.gov (United States)

    Lehman, Sean K.

    2012-12-18

    A wave-based tomographic imaging method and apparatus based upon one or more rotating radially outward oriented transmitting and receiving elements have been developed for non-destructive evaluation. At successive angular locations at a fixed radius, a predetermined transmitting element can launch a primary field and one or more predetermined receiving elements can collect the backscattered field in a "pitch/catch" operation. A Hilbert space inverse wave (HSIW) algorithm can construct images of the received scattered energy waves using operating modes chosen for a particular application. Applications include, improved intravascular imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts having existing access holes.

  17. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  18. Compressive Phase Contrast Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Maia, Filipe; MacDowell, Alastair; Marchesini, Stefano; Padmore, Howard A.; Parkinson, Dula Y.; Pien, Jack; Schirotzek, Andre; Yang, Chao

    2010-09-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. Interference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher contrast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  19. Stored Luminescence Computed Tomography

    CERN Document Server

    Cong, Wenxiang; Wang, Ge

    2013-01-01

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  20. Hyperspectral optical diffraction tomography

    CERN Document Server

    Jung, JaeHwang; Yoon, Jonghee; Park, YongKeun

    2015-01-01

    Here, we present a novel microscopic technique for measuring wavelength-dependent three-dimensional (3-D) distributions of the refractive indices (RIs) of microscopic samples in the visible wavelengths. Employing 3-D quantitative phase microscopy techniques with a wavelength-swept source, 3-D RI tomograms were obtained in the range of 450 - 700 nm with a spectral resolution of a few nanometers. The capability of the technique was demonstrated by measuring the hyperspectral 3-D RI tomograms of polystyrene beads, human red blood cells, and hepatocytes. The results demonstrate the potential for label-free molecular specific 3-D tomography of biological samples.

  1. Atom probe tomography today

    Directory of Open Access Journals (Sweden)

    Alfred Cerezo

    2007-12-01

    Full Text Available This review aims to describe and illustrate the advances in the application of atom probe tomography that have been made possible by recent developments, particularly in specimen preparation techniques (using dual-beam focused-ion beam instruments but also of the more routine use of laser pulsing. The combination of these two developments now permits atomic-scale investigation of site-specific regions within engineering alloys (e.g. at grain boundaries and in the vicinity of cracks and also the atomic-level characterization of interfaces in multilayers, oxide films, and semiconductor materials and devices.

  2. Optical Tomography in Combustion

    DEFF Research Database (Denmark)

    Evseev, Vadim

    in the lab using Fourier transform infrared spectroscopy techniques, including a new tomographic measurement scheme, sweeping scanning, having great potential for industrial applications with limited optical access. The results were compared to the reference point measurements on the same flame...... and the deviations are discussed. The methods are shown to have promising potential for future industrial applications. The new multichannel infrared spectrometer system as a first prototype of the infrared spectroscopic tomography system was developed in the PhD project for simultaneous fast transient infrared...

  3. Tomography finds waste sites

    Science.gov (United States)

    Bush, Susan M.

    Geophysical diffraction tomography (GDT), a remote sensing method, is being developed for hazardous waste site characterization by researchers at Oak Ridge National Laboratory, Tenn., with the support of the U.S. Army Toxic and Hazardous Materials Agency, Aberdeen Proving Ground, Md.More accurate assessment of hazardous sites translates into more efficient and less costly cleanup efforts by defining parameters such as waste site boundaries, geophysical site characteristics, buried container leakage, and hazardous material migration. Remote sensing devices eliminate the potential for environmental damage, safety hazards, or high costs associated with intrusive site characterization techniques.

  4. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  5. Integrated diffuse optical tomography and photoacoustic tomography: phantom validations

    OpenAIRE

    Li, Xiaoqi; Xi, Lei; Jiang, Ruixin; Yao, Lei; Jiang, Huabei

    2011-01-01

    We designed, fabricated and tested a novel imaging system that fuses diffuse optical tomography (DOT) and photoacoustic tomography (PAT) in a single platform. This platform takes advantages of both DOT and PAT, and can potentially provide dual-modality two dimensional functional and cellular images of the breast quantitatively. Here we describe this integrated platform along with initial tissue phantom validations.

  6. Resistive plate chambers in positron emission tomography

    Science.gov (United States)

    Crespo, Paulo; Blanco, Alberto; Couceiro, Miguel; Ferreira, Nuno C.; Lopes, Luís; Martins, Paulo; Ferreira Marques, Rui; Fonte, Paulo

    2013-07-01

    Resistive plate chambers (RPC) were originally deployed for high energy physics. Realizing how their properties match the needs of nuclear medicine, a LIP team proposed applying RPCs to both preclinical and clinical positron emission tomography (RPC-PET). We show a large-area RPC-PET simulated scanner covering an axial length of 2.4m —slightly superior to the height of the human body— allowing for whole-body, single-bed RPC-PET acquisitions. Simulations following NEMA (National Electrical Manufacturers Association, USA) protocols yield a system sensitivity at least one order of magnitude larger than present-day, commercial PET systems. Reconstruction of whole-body simulated data is feasible by using a dedicated, direct time-of-flight-based algorithm implemented onto an ordered subsets estimation maximization parallelized strategy. Whole-body RPC-PET patient images following the injection of only 2mCi of 18-fluorodesoxyglucose (FDG) are expected to be ready 7 minutes after the 6 minutes necessary for data acquisition. This compares to the 10-20mCi FDG presently injected for a PET scan, and to the uncomfortable 20-30minutes necessary for its data acquisition. In the preclinical field, two fully instrumented detector heads have been assembled aiming at a four-head-based, small-animal RPC-PET system. Images of a disk-shaped and a needle-like 22Na source show unprecedented sub-millimeter spatial resolution.

  7. Analyzing the Evolution of Membrane Fouling via a Novel Method Based on 3D Optical Coherence Tomography Imaging.

    Science.gov (United States)

    Li, Weiyi; Liu, Xin; Wang, Yi-Ning; Chong, Tzyy Haur; Tang, Chuyang Y; Fane, Anthony G

    2016-07-01

    The development of novel tools for studying the fouling behavior during membrane processes is critical. This work explored optical coherence tomography (OCT) to quantitatively interpret the formation of a cake layer during a membrane process; the quantitative analysis was based on a novel image processing method that was able to precisely resolve the 3D structure of the cake layer on a micrometer scale. Fouling experiments were carried out with foulants having different physicochemical characteristics (silica nanoparticles and bentonite particles). The cake layers formed at a series of times were digitalized using the OCT-based characterization. The specific deposit (cake volume/membrane surface area) and surface coverage were evaluated as a function of time, which for the first time provided direct experimental evidence for the transition of various fouling mechanisms. Axial stripes were observed in the grayscale plots showing the deposit distribution in the scanned area; this interesting observation was in agreement with the instability analysis that correlated the polarized particle groups with the small disturbances in the boundary layer. This work confirms that the OCT-based characterization is able to provide deep insights into membrane fouling processes and offers a powerful tool for exploring membrane processes with enhanced performance.

  8. An appraisal of golimumab in the treatment of severe, active nonradiographic axial spondyloarthritis

    Directory of Open Access Journals (Sweden)

    Paccou J

    2016-07-01

    Full Text Available Julien Paccou, René-Marc Flipo Department of Rheumatology, Lille University Hospital, Lille, France Abstract: Golimumab (Simponi® is a fully human tumor necrosis factor α inhibitor (TNFi antibody administered subcutaneously. In the European Union, golimumab is indicated for the treatment of adults with severe, active axial spondyloarthritis (axSpA, which includes both ankylosing spondylitis (AS and nonradiographic axSpA (nr-axSpA. In the US, it is indicated for the treatment of adults with active AS only. This article reviews the efficacy and tolerability of golimumab in nr-axSpA patients compared to other TNFi agents (adalimumab, infliximab, etanercept, and certolizumab pegol. In one ongoing, well-designed controlled study (GO-AHEAD, data at 16 weeks showed that treatment with golimumab (50 mg every 4 weeks was effective in improving the clinical signs and symptoms of disease in nr-axSpA patients. In addition, 16 weeks of treatment with golimumab reduced inflammation in the sacroiliac joints and spine in patients with nr-axSpA. Moreover, objective evidence of active inflammation at baseline, such as a positive magnetic resonance imaging scan and/or an elevated CRP level, was a good predictor of treatment response to golimumab. Golimumab was generally well tolerated in this study, with a tolerability profile consistent with that seen in previous clinical trials for other indications. Although additional long-term data are needed, current evidence indicates that golimumab is an effective option for the treatment of nr-axSpA. However, in the absence of comparative head-to-head trials, there is no recommended hierarchy for the first prescription of a TNFi agent for the treatment of either nr-axSpA or AS. Keywords: axial spondyloarthritis, nonradiographic axial spondyloarthritis, ankylosing spondylitis, golimumab, tumor necrosis factor α inhibitor, therapy

  9. Ambient Noise Tomography of the British Isles

    Science.gov (United States)

    Nicolson, H. J.; Curtis, A.; Baptie, B.

    2009-12-01

    In recent years, surface wave tomography using empirical Green’s functions computed via the ambient noise interferometry method has become an established approach to lithospheric imaging problems. To date, ambient noise tomography has been successfully applied to seismometer arrays in the United States, Australia, Iceland, China, South Africa, Europe and the Tibetan Plateau. The basis of the ambient seismic interferometry method is that, by cross-correlating noise data between two seismic stations and stacking over a long enough time period, one can approximate the Green’s Function that would have been recorded at one of the stations if the other had actually been a source. Consequently, one of the main advantages of ambient noise interferometry is that traditional seismic sources such as earthquakes or ballistics are not required; therefore it is ideal for application to seismically quiescent areas such as the British Isles. The British Isles are an archipelago located adjacent to the Eurasian continental shelf in a typically intra-plate setting, formed by a complex amalgamation of several terranes. These range from Laurentian north of the Highland Boundary fault to Avalonian south of the Iapetus Suture and evidence of the regions turbulent geological past can be inferred from its lithospheric structure. Previous studies of the structure of the British Isles considered relatively few seismic stations and/or were limited to using offshore shots, quarry blasts or teleseismic earthquakes as seismic energy sources. We have applied the ambient noise tomography method to noise data recorded on approximately 100 broadband and short period seismometers, including many new stations, in the British Isles and mainland Europe. This dense coverage of the British Isles allows us to image the crust and upper mantle velocity structure with a horizontal resolution in the region of 100km across the North Sea and 30km in the mainland United Kingdom. Here we present the first

  10. Axial clamp for nuclear reactor head penetration conoseal joints

    Energy Technology Data Exchange (ETDEWEB)

    Hackley, T.A.

    1987-03-31

    A method is described for forming a sealed coupling between two bodies, each body presenting an annular abutment surface. The respective bodies are arranged so that their respective annular abutment surfaces are axially adjacent one another, defining a space therebetween, wherein a deformable gasket is disposed within the space. The method comprises: providing one of the bodies with an annular projection; providing the other body with threads for receiving an annular locknut which can be tightened to bear against the annular projection of the one body; applying an external axial forced to the bodies for compressing the abutment surfaces together against the gasket to form a seal between the bodies; immobilizing the bodies relative to one another while the external force is being applied to the bodies by hand-tightening an annular locknut via the threads of the other body until the locknut abuts the annular projection of the one body, substantially preventing relative axial movement between the bodies when the external axial force is withdrawn; and withdrawing the external axial force applied to the bodies, leaving the two bodies coupled together via the seal.

  11. Rotordynamics of Turbine Labyrinth Seals with Rotor Axial Shifting

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available Rotors in high-performance steam turbines experience a significant axial shifting during starting and stopping processes due to thermal expansion, for example. This axial shifting could significantly alter the flow pattern and the flow-induced rotordynamic forces in labyrinth seals, which in turn, can considerably affect the rotor-seal system performance. This paper investigates the influence of the rotor axial shifting on leakage rate as well as rotordynamic forces in high-low labyrinth seals over a range of seal clearances and inlet swirl velocities. A well-established CFD-perturbation model was employed to predict the rotordynamic coefficients. A surprisingly large effect was detected for rotordynamic characteristics due to rotor shifting. It was also found that a less destabilizing effect arose from rotor axial shifting in the leakage flow direction, whereas a more destabilizing effect arose from shifting against the leakage flow direction. Further, a tentative explanation was proposed for the large sensitivities of dynamic forces to rotor axial shifting.

  12. Design and Simulation of Axial Flow Maglev Blood Pump

    Directory of Open Access Journals (Sweden)

    Huachun Wu

    2011-03-01

    Full Text Available The axial flow maglev blood pump (AFMBP has become a global research focus and emphasis for artificial ventricular assist device, which has no mechanical contact, mechanical friction, compact structure and light weight, can effectively solve thrombus and hemolysis. Magnetic suspension and impeller is two of the important parts in the axial flow maglev blood pump, and their structure largely determines the blood pump performance. The research adopts electromagnetic and fluid finite element analysis, and puts forward a method to design the magnetic suspension and impeller of axial flow blood pump, which tacks into account the small volume of axial blood pump. The magnetic bearing’s characteristics are evaluated by electromagnetic finite element analysis. The Blades have been designed by calculating aerofoil bone line, and make simulation analysis for different thicken ways of blade by Fluent software, and make a conclusion that the blade thickened with certain rules has better characteristics in the same conditions. The results will provide some guidance for design of axial flow maglev blood pump, and establish theoretical basis for application of the implantable artificial heart pump.

  13. An Axial Vector Photon in a Mirror World

    CERN Document Server

    Sharafiddinov, Rasulkhozha S

    2015-01-01

    The unity of symmetry laws emphasizes, in the case of a mirror CP-even Dirac Lagrangian, the ideas of the left- and right-handed axial-vector photons referring to long- and short-lived bosons of true neutrality, respectively. Such a difference in lifetimes expresses the unidenticality of masses, energies and momenta of axial-vector photons of the different components. They define the unified field theory equation of C-odd particles with an integral spin. Together with a new equation of a theory of truly neutral particles with the half-integral spin, the latter reflects the availability in their nature of the second type of the local axial-vector gauge transformation responsible for origination in the Lagrangian of C-oddity of an interaction Newton component giving an axial-vector mass to all the interacting particles and fields. The mirror axial-vector mass, energy and momentum operators constitute a CP-invariant equation of quantum mechanics, confirming that each of them can individually influence on matter ...

  14. Light Weakly Coupled Axial Forces: Models, Constraints, and Projections

    CERN Document Server

    Kahn, Yonatan; Mishra-Sharma, Siddharth; Tait, Tim M P

    2016-01-01

    We investigate the landscape of constraints on MeV-GeV scale, hidden U(1) forces with nonzero axial-vector couplings to Standard Model fermions. While the purely vector-coupled dark photon, which may arise from kinetic mixing, is a well-motivated scenario, several MeV-scale anomalies motivate a theory with axial couplings which can be UV-completed consistent with Standard Model gauge invariance. Moreover, existing constraints on dark photons depend on products of various combinations of axial and vector couplings, making it difficult to isolate the effects of axial couplings for particular flavors of SM fermions. We present a representative renormalizable, UV-complete model of a dark photon with adjustable axial and vector couplings, discuss its general features, and show how some UV constraints may be relaxed in a model with nonrenormalizable Yukawa couplings at the expense of fine-tuning. We survey the existing parameter space and the projected reach of planned experiments, briefly commenting on the relevan...

  15. An Axial-Vector Photon in a Mirror World

    Science.gov (United States)

    Sharafiddinov, Rasulkhozha S.

    2016-03-01

    The unity of symmetry laws emphasizes, in the case of a mirror CP-even Dirac Lagrangian, the ideas of the left- and right-handed axial-vector photons referring to long- and short-lived bosons of true neutrality, respectively. Such a difference in lifetimes expresses the unidenticality of masses, energies and momenta of axial-vector photons of the different components. They define the unified field theory equation of C-odd particles with an integral spin. Together with a new equation of a theory of truly neutral particles with the half-integral spin, the latter reflects the availability in their nature of the second type of the local axial-vector gauge transformation responsible for origination in the Lagrangian of C-oddity of an interaction Newton component giving an axial-vector mass to all the interacting particles and fields. The mirror axial-vector mass, energy and momentum operators constitute a CP-invariant equation of quantum mechanics, confirming that each of them can individually influence on matter field. Thereby, findings suggest at the level of the mass-charge structure of gauge invariance a new equation for the C-noninvariant Lagrangian.

  16. Auroral Tomography Workshop, Proceedings

    International Nuclear Information System (INIS)

    In ionospheric and atmospheric physics the importance of multi-station imaging has grown as a consequence of the availability of scientific grade CCD cameras with digital output and affordable massive computing power. Tomographic inversion techniques are used in many different areas, e.g. medicine, plasma research and space physics. The tomography workshop was announced to gather a limited group of people interested in auroral tomography or tomographic inversion methods in general. ALIS (Auroral Large Imaging System) is a multi-station ground-based system developed primarily for three-dimensional auroral imaging, however other non-auroral objects can be studied with ALIS, e.g. stratospheric clouds. Several of the contributions in the workshop dealt with problems related to geometries similar to the ALIS-configuration. The Proceedings contain written contributions received either in abstract form or as full papers. The Proceedings also contain contributions intended for the Workshop but not presented due to the absence of the speaker. Separate abstracts have been prepared for 15 of the 17 papers

  17. Internal tide oceanic tomography

    Science.gov (United States)

    Zhao, Zhongxiang

    2016-09-01

    A concept of internal tide oceanic tomography (ITOT) is proposed to monitor ocean warming on a global scale. ITOT is similar to acoustic tomography, but that work waves are internal tides. ITOT detects ocean temperature changes by precisely measuring travel time changes of long-range propagating internal tides. The underlying principle is that upper ocean warming strengthens ocean stratification and thus increases the propagation speed of internal tides. This concept is inspired by recent advances in observing internal tides by satellite altimetry. In particular, a plane wave fit method can separately resolve multiple internal tidal waves and thus accurately determines the phase of each wave. Two examples are presented to demonstrate the feasibility and usefulness of ITOT. In the eastern tropical Pacific, the yearly time series of travel time changes of the M2 internal tide is closely correlated with the El Niño-Southern Oscillation index. In the North Atlantic, significant interannual variations and bidecadal trends are observed and consistent with the changes in ocean heat content measured by Argo floats. ITOT offers a long-term, cost-effective, environmentally friendly technique for monitoring global ocean warming. Future work is needed to quantify the accuracy of this technique.

  18. Advances in neutron tomography

    Indian Academy of Sciences (India)

    W Treimer

    2008-11-01

    In the last decade neutron radiography (NR) and tomography (NCT) have experienced a number of improvements, due to the well-known properties of neutrons interacting with matter, i.e. the low attenuation by many materials, the strong attenuation by hydrogenous constituent in samples, the wavelength-dependent attenuation in the neighbourhood of Bragg edges and due to better 2D neutron detectors. So NR and NCT were improved by sophisticated techniques that are based on the attenuation of neutrons or on phase changes of the associated neutron waves if they pass through structured materials. Up to now the interaction of the neutron spin with magnetic fields in samples has not been applied to imaging techniques despite the fact that it was proposed many years ago. About ten years ago neutron depolarization as imaging signal for neutron radiography or tomography was demonstrated and in principle it works. Now one can present much improved test experiments using polarized neutrons for radiographic imaging. For this purpose the CONRAD instrument of the HMI was equipped with polarizing and analysing benders very similar to conventional scattering experiments using polarized neutrons. Magnetic fields in different coils and in samples (superconductors) at low temperatures could be visualized. In this lecture a summary about standard signals (attenuation) and the more `sophisticated' imaging signals as refraction, small angle scattering and polarized neutrons will be given.

  19. Waste inspection tomography (WIT)

    Energy Technology Data Exchange (ETDEWEB)

    Bernardi, R.T. [Bio-Imaging Research, Inc., Lincolnshire, IL (United States)

    1995-10-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU.

  20. Compressed sensing electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Leary, Rowan, E-mail: rkl26@cam.ac.uk [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Saghi, Zineb; Midgley, Paul A. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Holland, Daniel J. [Department of Chemical Engineering and Biotechnology, University of Cambridge, New Museums Site, Pembroke Street, Cambridge CB2 3RA (United Kingdom)

    2013-08-15

    The recent mathematical concept of compressed sensing (CS) asserts that a small number of well-chosen measurements can suffice to reconstruct signals that are amenable to sparse or compressible representation. In addition to powerful theoretical results, the principles of CS are being exploited increasingly across a range of experiments to yield substantial performance gains relative to conventional approaches. In this work we describe the application of CS to electron tomography (ET) reconstruction and demonstrate the efficacy of CS–ET with several example studies. Artefacts present in conventional ET reconstructions such as streaking, blurring of object boundaries and elongation are markedly reduced, and robust reconstruction is shown to be possible from far fewer projections than are normally used. The CS–ET approach enables more reliable quantitative analysis of the reconstructions as well as novel 3D studies from extremely limited data. - Highlights: • Compressed sensing (CS) theory and its application to electron tomography (ET) is described. • The practical implementation of CS–ET is outlined and its efficacy demonstrated with examples. • High fidelity tomographic reconstruction is possible from a small number of images. • The CS–ET reconstructions can be more reliably segmented and analysed quantitatively. • CS–ET is applicable to different image content by choice of an appropriate sparsifying transform.

  1. Fluoroscopic lumbar interlaminar epidural injections in managing chronic lumbar axial or discogenic pain

    Directory of Open Access Journals (Sweden)

    Manchikanti L

    2012-08-01

    Full Text Available Laxmaiah Manchikanti,1,2 Kimberly A Cash,1 Carla D McManus,1 Vidyasagar Pampati,1 Ramsin Benyamin3,41Pain Management Center of Paducah, Paducah, KY; 2University of Louisville, Louisville, KY; 3Millennium Pain Center, Bloomington, IL; 4University of Illinois, Urbana-Champaign, IL, USAAbstract: Among the multiple causes of chronic low back pain, axial and discogenic pain are common. Various modalities of treatments are utilized in managing discogenic and axial low back pain including epidural injections. However, there is a paucity of evidence regarding the effectiveness, indications, and medical necessity of any treatment modality utilized for managing axial or discogenic pain, including epidural injections. In an interventional pain management practice in the US, a randomized, double-blind, active control trial was conducted. The objective was to assess the effectiveness of lumbar interlaminar epidural injections of local anesthetic with or without steroids for managing chronic low back pain of discogenic origin. However, disc herniation, radiculitis, facet joint pain, or sacroiliac joint pain were excluded. Two groups of patients were studied, with 60 patients in each group receiving either local anesthetic only or local anesthetic mixed with non-particulate betamethasone. Primary outcome measures included the pain relief-assessed by numeric rating scale of pain and functional status assessed by the, Oswestry Disability Index, Secondary outcome measurements included employment status, and opioid intake. Significant improvement or success was defined as at least a 50% decrease in pain and disability. Significant improvement was seen in 77% of the patients in Group I and 67% of the patients in Group II. In the successful groups (those with at least 3 weeks of relief with the first two procedures, the improvement was 84% in Group I and 71% in Group II. For those with chronic function-limiting low back pain refractory to conservative management

  2. Computerised tomography of the orbits

    Directory of Open Access Journals (Sweden)

    Talwar Inder

    1988-01-01

    Full Text Available Computerised Tomography has revolutionised the approach to many problems, especially orbital diseases. It is a simple, safe, non-invasive diagnostic examination done on an out patient. Computerised Tomography not only shows the presence of a lesion but also shows the extent of the disease and its relationship to other intraorbital and adjacent structures. With coronal scans, relationship of orbital disease to the optic nerve and extraocular muscles can be well demonstrated. However it must be remembered that Computerised Tomography is not a microscope to give histopathological diagnosis but we can often draw a conclusion of the nature of the disease by Computerised′ Tomography appearances and clinical details. Now Computerised Tomography has become the primary investigation of choice in evaluating orbital disease.

  3. Liquid Axial Mixing in Packed Tower at Elevated Pressure

    Institute of Scientific and Technical Information of China (English)

    唐忠利; 张鹏; 等

    2003-01-01

    Liquid phase axial mixing was measured with the tracer technique in a packed column with inner diameter of 0.15m,in which the structured packing,Mellapak 350Y,was installed.Tap water as the liquid phase flowed down through the column and stagnant gas was at elevated pressure ranging from atmospheric to 2.0MPa.The model parameters of Bo andθwere estimated with the least square method in the time domain.As liquid flow rate was increased,the liquid axial mixing decreased.under our experimental conditions,the effect of pressure on Bo number on single liquid phase was negligible,and eddy diffusion was believed to be the primary cause of axial mixing in liquid phase.

  4. Unsteady cooperative flow type in the axial compressor

    Institute of Scientific and Technical Information of China (English)

    ZHENG Xinqian; ZHOU Sheng; HOU Anping; XIONG Jinsong

    2005-01-01

    For increasing the performance of the axial compressor, a method for realizing unsteady cooperative flow type is proposed in this paper as a critical objective in the new generation of the axial compressor design system. Unsteady excitations were utilized to trigger the transformation from the unsteady natural flow pattern into the unsteady cooperative flow pattern, resulting in increment of aerodynamic performances of axial compressor. Numerical simulations show that distinct positive effect can be obtained for the 2D cascade in a wide range of subsonic working conditions. No positive effect can be observed under the 2D supersonic working conditions and unsteady excitations have little influence on the flow field space-time structure. However, positive effect can be obtained under the 3D transsonic working conditions. In addition, engineering applications of unsteady cooperative flow type are discussed.

  5. Numerical analysis of cavitation within slanted axial-flow pump

    Institute of Scientific and Technical Information of China (English)

    张睿; 陈红勋

    2013-01-01

    In this paper, the cavitating flow within a slanted axial-flow pump is numerically researched. The hydraulic and cavitation performance of the slanted axial-flow pump under different operation conditions are estimated. Compared with the experimental hydraulic performance curves, the numerical results show that the filter-based model is better than the standard k-e model to predict the parameters of hydraulic performance. In cavitation simulation, compared with the experimental results, the proposed numerical method has good predicting ability. Under different cavitation conditions, the internal cavitating flow fields within slanted axial-flow pump are investigated. Compared with flow visualization results, the major internal flow features can be effectively grasped. In order to explore the origin of the cavitation performance breakdown, the Boundary Vorticity Flux (BVF) is introduced to diagnose the cavitating flow fields. The analysis results indicate that the cavitation performance drop is relevant to the instability of cavitating flow on the blade suction surface.

  6. STED microscopy based on axially symmetric polarized vortex beams

    Science.gov (United States)

    Zhehai, Zhou; Lianqing, Zhu

    2016-03-01

    A stimulated emission depletion (STED) microscopy scheme using axially symmetric polarized vortex beams is proposed based on unique focusing properties of such kinds of beams. The concept of axially symmetric polarized vortex beams is first introduced, and the basic principle about the scheme is described. Simulation results for several typical beams are then shown, including radially polarized vortex beams, azimuthally polarized vortex beams, and high-order axially symmetric polarized vortex beams. The results indicate that sharper doughnut spots and thus higher resolutions can be achieved, showing more flexibility than previous schemes based on flexible modulation of both phase and polarization for incident beams. Project supported by the National Natural Science Foundation of China (Grant Nos. 61108047 and 61475021), the Natural Science Foundation of Beijing, China (Grant No. 4152015), the Program for New Century Excellent Talents in Universities of China (Grant No. NCET-13-0667), and the Top Young Talents Support Program of Beijing, China (Grant No. CIT&TCD201404113).

  7. Identification du comportement de composites en fatigue bi-axiale

    OpenAIRE

    Busca, Damien

    2014-01-01

    La connaissance du comportement de composites sous un état de contraintes multi-axial reste un enjeu majeur pour l’optimisation du dimensionnement des structures. La machine de fatigue bi-axiale présente au LGP permet de générer un état de contrainte bi-axial par l’utilisation d’éprouvettes cruciformes. La conception des éprouvettes reste un enjeu majeur pour les chercheurs pour répondre aux problèmes spécifiques liés aux matériaux composites. Un nouveau type d’éprouvette cruciforme en compos...

  8. Unsteady Numerical Simulation of Cavitation in Axial Turbine

    Directory of Open Access Journals (Sweden)

    Nabil H. Mostafa

    2012-09-01

    Full Text Available A 3-D numerical study has been carried out in order to study the unsteady, turbulent, void growth and cavitation simulation inside the passage of the axial flow turbine. In this study a 3D Navier-Stokes code was used (CFDRC, 2008 to model the two-phase flow field around a four blades axial turbine. The governing equations are discretized on a structured grid using an upwind difference scheme. The numerical simulation used the standard k-ε turbulence model to account for the turbulence effect. The numerical simulation of void growth and cavitation in an axial turbine was studied under unsteady calculating. Pressure distribution and vapour volume fraction were completed versus time at different condition. The computational code has been validated by comparing the predicated numerical results with the previous studies. The comparison shows good agreement.

  9. The small axial charge of the N(1535) resonance

    CERN Document Server

    an, C S

    2008-01-01

    There is a natural cancellation between the contributions of the $qqq$ and $qqqq\\bar q$ components to the axial charge of the N(1535) resonance. While the probability of the former is larger than that of the latter, its coefficient in the axial charge expression is exceptionally small. The magnitude of two of the corresponding coefficients of the $qqqq\\bar q$ components are in contrast large and have the opposite sign. This result provides a phenomenological illustration of the recent unquenched lattice calculation result that the axial charge of the N(1535) resonance is very small, if not vanishing \\cite{takah}. The result sets an upper limit on the magnitude of the probability of $qqqq\\bar q$ components as well.

  10. A simple approach to the ABJ axial anomaly

    International Nuclear Information System (INIS)

    A very simple semi-quantitative derivation of the Adler-Bell-Jackiw (ABJ) axial anomaly is given, based on an investigation of the absorptive part of the VVA triangle graph and dispersion relations. Essential ingredients of our discussion are: normal Ward identities for the absorptive part of the relevant diagram, dimensional analysis, unitarity, and energy-momentum conservation. An explanation of the physical origin of axial anomaly, proposed in some earlier treatments within such a dispersive framework, is critically examined. In particular, the interpretation of the ABJ anomaly as an analogy of the Lee-Nauenberg effect occurring in the massless limit of spinor electrodynamics is shown to be fallacious

  11. Vector and Axial Currents in Wilson Chiral Perturbation Theory

    CERN Document Server

    Aoki, Sinya; Sharpe, Stephen R

    2009-01-01

    We reconsider the construction of the vector and axial-vector currents in Wilson Chiral Perturbation Theory (WChPT), the low-energy effective theory for lattice QCD with Wilson fermions. We discuss in detail the finite renormalization of the currents that has to be taken into account in order to properly match the currents. We explicitly show that imposing the chiral Ward identities on the currents does, in general, affect the axial-vector current at O(a). As an application of our results we compute the pion decay constant to one loop in the two flavor theory. Our result differs from previously published ones.

  12. Instability of Meridional Axial System in f(R) Gravity

    CERN Document Server

    Sharif, M

    2015-01-01

    We analyze dynamical instability of non-static reflection axial stellar structure by taking into account generalized Euler's equation in metric $f(R)$ gravity. Such an equation is obtained by contracting Bianchi identities of usual anisotropic and effective stress-energy tensors, which after using radial perturbation technique gives modified collapse equation. In the realm of $R+\\epsilon R^n$ gravity model, we investigate instability constraints at Newtonian and post-Newtonian approximations. We find that instability of meridional axial self-gravitating system depends upon static profile of structure coefficients while $f(R)$ extra curvature terms induce stability to the evolving celestial body.

  13. Axial crack propagation and arrest in pressurized fuselage

    Science.gov (United States)

    Kosai, M.; Shimamoto, A.; Yu, C.-T.; Walker, S. I.; Kobayashi, A. S.; Tan, P.

    1994-01-01

    The crack arrest capability of a tear strap in a pressurized precracked fuselage was studied through instrumented axial rupture tests of small scale models of an idealized fuselage. Upon pressurization, rapid crack propagation initiated at an axial through crack along the stringer and immediately kinked due to the mixed modes 1 and 2 state caused by the one-sided opening of the crack flap. The diagonally running crack further turned at the tear straps. Dynamic finite element analysis of the rupturing cylinder showed that the crack kinked and also ran straight in the presence of a mixed mode state according to a modified two-parameter crack kinking criterion.

  14. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    -scale structural elements in fast sandwich vessels. Two of the crushing tests are simulated with the explicit finite element software LS-DYNA3D. The key results are load-end shortening relationship and the energy dissipation. Good agreement between the numerical predictions and the experiments are obtained......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  15. Vector and axial currents in Wilson chiral perturbation theory

    International Nuclear Information System (INIS)

    We reconsider the construction of the vector and axial-vector currents in Wilson Chiral Perturbation Theory, the low-energy effective theory for lattice QCD with Wilson fermions. We discuss in detail the finite renormalization of the currents that has to be taken into account in order to properly match the currents. We explicitly show that imposing the chiral Ward identities on the currents does, in general, affect the axial-vector current at O(a). As an application of our results we compute the pion decay constant to one loop in the two-flavor theory. Our result differs from previously published ones.

  16. Spectral analysis in thin tubes with axial heterogeneities

    KAUST Repository

    Ferreira, Rita

    2015-01-01

    In this paper, we present the 3D-1D asymptotic analysis of the Dirichlet spectral problem associated with an elliptic operator with axial periodic heterogeneities. We extend to the 3D-1D case previous 3D-2D results (see [10]) and we analyze the special case where the scale of thickness is much smaller than the scale of the heterogeneities and the planar coefficient has a unique global minimum in the periodic cell. These results are of great relevance in the comprehension of the wave propagation in nanowires showing axial heterogeneities (see [17]).

  17. Infrared and terahertz radiation of a crystal at axial channeling

    International Nuclear Information System (INIS)

    Basic properties of radiation of a crystal lattice excited by an axial channeling particle are considered. It is shown that a coherent radiation of atoms occurs if the frequency of oscillations of the channeled particle comes to a resonance with the vibrational mode of the crystal. Spectral and angular distribution of radiation and its polarization are calculated. In case of a relativistic channeled particle, the radiation of atoms is generated into a narrow cone in the direction of a crystallographic axis along which the particle is channeling. The radiation of atoms exited at axial channelling has significant degree of circular polarization

  18. Buckling localization in a cylindrical panel under axial compression

    DEFF Research Database (Denmark)

    Tvergaard, Viggo; Needleman, A.

    2000-01-01

    Localization of an initially periodic buckling pattern is investigated for an axially compressed elastic-plastic cylindrical panel of the type occurring between axial stiffeners on cylindrical shells. The phenomenon of buckling localization and its analogy with plastic flow localization in tensile......, but where subsequently the load starts to increase again, it is found that near the local load minimum, the buckling pattern switches back to a periodic type of pattern. The inelastic material behavior of the panel is described in terms of J(2) corner theory, which avoids the sometimes unrealistically...

  19. The Role of 18F-FDG-Positron Emission Tomography/Computed Tomography in Staging Primary Breast Cancer

    Directory of Open Access Journals (Sweden)

    Naoki Niikura, Naoto T. Ueno

    2010-01-01

    Full Text Available Despite Medicare approving the use of positron emission tomography/computed tomography (PET/CT in staging primary breast cancer, little evidence is available to support the use of 18F-FDG-PET/CT for the detection of distant metastases in the initial staging of breast cancer. In this review of the literature listed in MEDLINE, we examine whether 18F-FDG-PET/CT may play a role in the initial staging of breast cancer. We discuss studies comparing PET/CT with conventional imaging for diagnosing distant metastases and axillary and extra-axillary lymph node metastases.

  20. 4-D Photoacoustic Tomography

    Science.gov (United States)

    Xiang, Liangzhong; Wang, Bo; Ji, Lijun; Jiang, Huabei

    2013-01-01

    Photoacoustic tomography (PAT) offers three-dimensional (3D) structural and functional imaging of living biological tissue with label-free, optical absorption contrast. These attributes lend PAT imaging to a wide variety of applications in clinical medicine and preclinical research. Despite advances in live animal imaging with PAT, there is still a need for 3D imaging at centimeter depths in real-time. We report the development of four dimensional (4D) PAT, which integrates time resolutions with 3D spatial resolution, obtained using spherical arrays of ultrasonic detectors. The 4D PAT technique generates motion pictures of imaged tissue, enabling real time tracking of dynamic physiological and pathological processes at hundred micrometer-millisecond resolutions. The 4D PAT technique is used here to image needle-based drug delivery and pharmacokinetics. We also use this technique to monitor 1) fast hemodynamic changes during inter-ictal epileptic seizures and 2) temperature variations during tumor thermal therapy.

  1. Neurovascular photoacoustic tomography

    Directory of Open Access Journals (Sweden)

    Song Hu

    2010-06-01

    Full Text Available Neurovascular coupling refers to the relationship between neuronal activities and downstream hemodynamic responses. Photoacoustic tomography (PAT, enabling comprehensive label-free imaging of hemodynamic activities with highly scalable penetration and spatial resolution, has great potential in the study of neurovascular coupling. In this review, we first introduce the technical basis of hemodynamic PAT—including label-free quantification of total hemoglobin concentration, blood oxygenation, and blood flow—as well as its applications in hemodynamic monitoring. Then, we demonstrate the potential application of PAT in neurovascular imaging by highlighting representative studies on cerebral vascular responses to whisker stimulation and Alzheimer’s disease. Finally, potential research directions and associated technical challenges are discussed.

  2. Pion electroproduction, partially conserved axial-vector current, chiral Ward identities, and the axial form factor revisited

    International Nuclear Information System (INIS)

    We reinvestigate Adler's partially conserved axial-vector current relation in the presence of an external electromagnetic field within the framework of QCD coupled to external fields. We discuss pion electroproduction within a tree-level approximation to chiral perturbation theory and explicitly verify a chiral Ward identity referred to as the Adler-Gilman relation. We critically examine soft-momentum techniques and point out how inadmissable approximations may lead to results incompatible with chiral symmetry. As a result we confirm that threshold pion electroproduction is indeed a tool to obtain information on the axial form factor of the nucleon

  3. Quantum-polarization state tomography

    Science.gov (United States)

    Bayraktar, Ömer; Swillo, Marcin; Canalias, Carlota; Björk, Gunnar

    2016-08-01

    We propose and demonstrate a method for quantum-state tomography of qudits encoded in the quantum polarization of N -photon states. This is achieved by distributing N photons nondeterministically into three paths and their subsequent projection, which for N =1 is equivalent to measuring the Stokes (or Pauli) operators. The statistics of the recorded N -fold coincidences determines the unknown N -photon polarization state uniquely. The proposed, fixed setup manifestly rules out any systematic measurement errors due to moving components and allows for simple switching between tomography of different states, which makes it ideal for adaptive tomography schemes.

  4. Plasma tomography of higher resolution

    International Nuclear Information System (INIS)

    New microwave tomography scheme for plasma diagnostic is suggested - ray based diffraction tomography, which promises to reach a resolution, close to a diffraction limit. Besides, this scheme is less sensitive to the amplitude fluctuations as compared with traditional phase tomography. The method, which was suggested earlier for the ionosphere applications, can be helpful also for revealing of electron density inhomogeneities in a hot plasma. The algorithm, used for processing, is able to reveal small-scale plasma inhomogeneities of characteristic length, comparable with microwave wavelength, that is up to 1-3 cm. (author)

  5. Time-multiplexed chromatic-controlled axial diffractive optical elements

    Science.gov (United States)

    Martínez-García, Antonio

    2010-07-01

    Programmable diffractive optical elements (DOEs) with axial response have many interesting applications, including diffractive lenses, axicons, and optical tweezers. In all these cases, it is essential to properly select the modulation configuration of the spatial light modulator (SLM) where the DOE is displayed, in order to avoid the undiffracted zero order component that appears on axis and overlaps the desired axial response. However, in general, the chromatic dispersion in liquid crystal SLMs prevents the cancellation of the zero order for a broadband light source, thus limiting the possibilities for polychromatic programmable axial DOEs. We operate a ferroelectric liquid crystal on silicon display with polychromatic illumination and with a specific polarization configuration that provides binary π-phase modulation for all wavelengths. Since this type of modulation cancels the undiffracted zero order, we use this SLM to display DOEs with axial response. Moreover, chromatic control is achieved by time-multiplexing sequences of properly scaled DOEs with the corresponding selection of the input wavelength by means of an electronically controlled color-filter wheel. The presented experimental results include wavelength-controlled diffraction gratings, axicons, and vortex-producing lenses.

  6. Elevated temperature axial and torsional fatigue behavior of Haynes 188

    Science.gov (United States)

    Bonacuse, Peter J.; Kalluri, Sreeramesh

    1992-06-01

    The results of high-temperature axial and torsional low-cycle fatigue experiments performed on Haynes 188, a wrought cobalt-base superalloy, are reported. Fatigue tests were performed at 760 C in air on thin-walled tubular specimens at various ranges under strain control. Data are also presented for coefficient of thermal expansion, elastic modulus, and shear modulus at various temperatures from room to 1000 C, and monotonic and cyclic stress-strain curves in tension and in shear at 760 C. The data set is used to evaluate several multiaxial fatigue life models (most were originally developed for room temperature multiaxial life prediction) including von Mises equivalent strain range (ASME boiler and pressure vessel code), Manson-Halford, Modified Multiaxiality Factor (proposed here), Modified Smith-Watson-Topper, and Fatemi-Socie-Kurath. At von Mises equivalent strain ranges (the torsional strain range divided by the square root of 3, taking the Poisson's ratio to be 0.5), torsionally strained specimens lasted, on average, factors of 2 to 3 times longer than axially strained specimens. The Modified Multiaxiality Factor approach shows promise as a useful method of estimating torsional fatigue life from axial fatigue data at high temperatures. Several difficulties arose with the specimen geometry and extensometry used in these experiments. Cracking at extensometer probe indentations was a problem at smaller strain ranges. Also, as the largest axial and torsional strain range fatigue tests neared completion, a small amount of specimen buckling was observed.

  7. Defining active sacroiliitis on MRI for classification of axial spondyloarthritis

    DEFF Research Database (Denmark)

    Lambert, Robert G W; Bakker, Pauline A C; van der Heijde, Désirée;

    2016-01-01

    OBJECTIVES: To review and update the existing definition of a positive MRI for classification of axial spondyloarthritis (SpA). METHODS: The Assessment in SpondyloArthritis International Society (ASAS) MRI working group conducted a consensus exercise to review the definition of a positive MRI for...

  8. Dynamic Behaviors of Axially Moving Viscoelastic Plate with Varying Thicknessn

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yinfeng; WANG Zhongmin

    2009-01-01

    Structural components of varying thickness draw increasing attention these days due to economy and light-weight considerations. In view of the absence of research in vibration analysis of viscoelastic plate with varying thickness, this study devotes to investigate the dynamic behaviors of axially moving viscoelastic plate with varying thickness. Based on the thin plate theory and the two-dimensional viscoelastic differential constitutive relation, the differential equation of motion of the axially moving viscoelastic rectangular plate is derived, the plate constituted by Kelvin-Voigt model has linearly varying thickness in the y-direction. The dimensionless complex frequencies of axially moving viscoelastic plate with four edges simply supported are calculated by the differential quadrature method, curves of real parts and imaginary parts of the first three-order dimensionless complex frequencies versus dimensionless moving speed are obtained, the effects of the aspect ratio, thickness ratio, the dimensionless moving speed and delay time on the dynamic behaviors of the axially moving viscoelastic rectangular plate with varying thickness are analyzed. When other parameters keep constant, with the decrease of thickness ratio, the real parts of the first three-order natural frequencies decrease, and the critical divergence speeds of various modes decrease too, moreover, whether the delay time is large or small, the frequencies are all complex numbers.

  9. Effect of axial modes on Doppler experiments with gas lasers

    NARCIS (Netherlands)

    Bolwijn, P.T.; Peek, Th.H.; Alkemade, C.T.J.

    1966-01-01

    Power output modulation was obtained by using a moving mirror reflecting one beam back into the laser interferometer. The strong dependence of modulation amplitude on the distance between moving mirror and laser is related to the number, n, of excited axial modes for n > 1.

  10. AXIAL DEFFLECTION STUDIES OF RING SHAPED FORCE TRANSDUCER: A REVIEW

    Directory of Open Access Journals (Sweden)

    SUDHIR KUMAR,

    2011-01-01

    Full Text Available The ring shaped force transducers are widely used in practice and are available in varying capacities from few hundred newtons to mega newtons. The present paper discusses the deflection studies of thering shaped force transducers under action of axial forces. Various methods leading to the measurement of deflection have been discussed and compared here.

  11. On aspects of vibration of axially moving continua

    NARCIS (Netherlands)

    Hageraats-Ponomareva, S.

    2009-01-01

    In axially moving structures like conveyor belt systems, magnetic tapes, and so on, vibrations occur due to the presence of different kinds of imperfections in the systems. For these structures internal resonances can lead to severe vibrations. Resonance free conveyor belt systems can be constructed

  12. Dynamic Response of Axially Loaded Euler-Bernoulli Beams

    DEFF Research Database (Denmark)

    Bayat, M.; Barari, Amin; Shahidi, M.

    2011-01-01

    The current research deals with application of a new analytical technique called Energy Balance Method (EBM) for a nonlinear problem. Energy Balance Method is used to obtain the analytical solution for nonlinear vibration behavior of Euler-Bernoulli beams subjected to axial loads. Analytical...

  13. View of the Axial Field Spectrometer (R807)

    CERN Multimedia

    1980-01-01

    In this view of the Axial Field Spectrometer at I8, the vertical uranium/scintillator hadron calorimeter (just left of centre) is retracted to give access to the cylindrical central drift chamber. The yellow iron structure served as a filter to identify muons, with MWPCs and the array of Cherenkov counters to the right.

  14. FINITE ELEMENT ANALYSIS OF AXIAL FEED BAR ROLLING

    Institute of Scientific and Technical Information of China (English)

    C.G. Xu; G.H. Liu; G.S. Ren; Z. Shen; C.P. Ma; W. W. Ren

    2007-01-01

    A flexible technique of hot working of bars by axial feed rolling was introduced. The processdeformation, strain field, stress field, and temperature field of the parts are analyzed by finite elementmethod (FEM)-simulation software DEFORM-3D. The material flow rule and tool load have beeninvestigated.

  15. COMPARISON OF AXIAL FAN ROTOR EXPERIMENTAL DATA WITH CFD SIMULATION

    OpenAIRE

    Aleš Prachař

    2016-01-01

    Data obtained from an experimental simulation on a new test rig for axial fans are compared to a CFD simulation. The Edge solver is used and the development needed for the simulation (boundary conditions, free stream consistency) is described. Adequate agreement between the measured and calculated data is observed.

  16. COMPARISON OF AXIAL FAN ROTOR EXPERIMENTAL DATA WITH CFD SIMULATION

    Directory of Open Access Journals (Sweden)

    Aleš Prachař

    2016-02-01

    Full Text Available Data obtained from an experimental simulation on a new test rig for axial fans are compared to a CFD simulation. The Edge solver is used and the development needed for the simulation (boundary conditions, free stream consistency is described. Adequate agreement between the measured and calculated data is observed.

  17. On the generation techniques of axially symmetric stationary metrics

    Indian Academy of Sciences (India)

    S Chaudhuri

    2002-03-01

    In the present paper, a relationship between the method of Gutsunaev–Manko and the soliton technique (for two-soliton solutions) of Belinskii–Zakharov, for generating solutions of axially symmetric stationary space-times in general relativity is discussed.

  18. Test Procedure for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test procedure described in the following is used when examining the effects of static or cyclic loading on the skin friction of an axially loaded pile in dense sand. The pile specimen is only loaded in tension to avoid any contribution from the base resistance. The pile dimensions are chosen...

  19. A non-commutative time-frequency tomography

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The characterization of non-stationary signal requires joint time and frequency information. However, time and frequency are a pair of non-commuting variables that cannot constitute a joint probability density in the time-frequency plane. The time-frequency distributions have difficult interpretation problems arising from negative and complex values or spurious components. In this paper, we get time-frequency information from the marginal distributions in rotated directions in the time-frequency plane. The rigorous probability interpretation of the marginal distributions is without any ambiguities. This time-frequency transformation is similar to the computerized axial tomography (CT or CAT) and is applied to signal analysis and signal detection and reveals a lot of advantages especially in the signal detection of the low signal/noise (S/N).

  20. Optical Coherence Tomography of Retinal and Choroidal Tumors

    Directory of Open Access Journals (Sweden)

    Emil Anthony T. Say

    2011-01-01

    Full Text Available Optical coherence tomography (OCT has revolutionized the field of ophthalmology since its introduction 20 years ago. Originally intended primarily for retina specialists to image the macula, it has found its role in other subspecialties that include glaucoma, cornea, and ocular oncology. In ocular oncology, OCT provides axial resolution to approximately 7 microns with cross-sectional images of the retina, delivering valuable information on the effects of intraocular tumors on the retinal architecture. Some effects include retinal edema, subretinal fluid, retinal atrophy, photoreceptor loss, outer retinal thinning, and retinal pigment epithelial detachment. With more advanced technology, OCT now provides imaging deeper into the choroid using a technique called enhanced depth imaging. This allows characterization of the thickness and reflective quality of small (<3 mm thick choroidal lesions including choroidal nevus and melanoma. Future improvements in image resolution and depth will allow better understanding of the mechanisms of visual loss, tumor growth, and tumor management.

  1. Imaging port wine stains by fiber optical coherence tomography

    Science.gov (United States)

    Zhao, Shiyong; Gu, Ying; Xue, Ping; Guo, Jin; Shen, Tingmei; Wang, Tianshi; Huang, Naiyan; Zhang, Li; Qiu, Haixia; Yu, Xin; Wei, Xunbin

    2010-05-01

    We develop a fiber optical coherence tomography (OCT) system in the clinical utility of imaging port wine stains (PWS). We use our OCT system on 41 patients with PWS to document the difference between PWS skin and contralateral normal skin. The system, which operates at 4 frames/s with axial and transverse resolutions of 10 and 9 μm, respectively, in the skin tissue, can clearly distinguish the dilated dermal blood vessels from normal tissue. We present OCT images of patients with PWS and normal human skin. We obtain the structural parameters, including epidermal thickness and diameter and depth of dilated blood vessels. We demonstrate that OCT may be a useful tool for the noninvasive imaging of PWS. It may help determine the photosensitizer dose and laser parameters in photodynamic therapy for treating port wine stains.

  2. Toward an automated method for optical coherence tomography characterization

    Science.gov (United States)

    Strupler, Mathias; Beckley, Amber M.; Benboujja, Fouzi; Dubois, Sylvain; Noiseux, Isabelle; Mermut, Ozzy; Bouchard, Jean-Pierre; Boudoux, Caroline

    2015-12-01

    With the increasing use of optical coherence tomography (OCT) in biomedical applications, robust yet simple methods for calibrating and benchmarking a system are needed. We present here a procedure based on a calibration object complemented with an algorithm that analyzes three-dimensional OCT datasets to retrieve key characteristics of an OCT system. The calibration object combines state-of-the-art tissue phantom material with a diamond-turned aluminum multisegment mirror. This method is capable of determining rapidly volumetric field-of-view, axial resolution, and image curvature. Moreover, as the phantom material mimics biological tissue, the system's signal and noise levels can be evaluated in conditions close to biological experiments. We believe this method could improve OCT quantitative data analysis and help OCT data comparison for longitudinal or multicenter studies.

  3. Fluid Chemistry Through an Eruption Cycle at Axial Seamount 1998-2011

    Science.gov (United States)

    Butterfield, D. A.; Chadwick, B.; Lilley, M. D.; Roe, K. K.; Lupton, J. E.; Dziak, R. P.; Walker, S. L.; Olson, E. J.; Evans, L. J.

    2011-12-01

    A primary goal for the NeMO seafloor observatory at Axial Seamount was to monitor and study a hydrothermal system through the cycle from one eruption to the next. With the January 1998 eruption and the April 2011 eruption discovered during Jason ROV operations in late July this year, that goal has now been accomplished. Based on observations and fluid temperature/chemistry measurements before and after both eruptions, there are common features leading up to and following the eruptions. Both eruptions at Axial originated in the SE corner of the caldera associated with the S Rift Zone. Isolated snowblower vents were found on new lava following both eruptions. Centimeter-thick orange hydrothermal mats formed rapidly on the new lava flows. There is some evidence that the fluids from ASHES vent field, located near the SW caldera wall, were hottest before the 1998 eruption. A second high-temperature vent field is located in the SE caldera just east of the recent lava flows. Lava flows came close to both high-temperature fields in 2011, but did not flow over any known chimneys. Recorded time series for several high-temperature vents show increasing temperatures from 2001 through 2010. Vent fluid chlorinity decreased at ASHES for 0.5 to 2 years following the 1998 eruption. As of 3.5 months after the 2011 eruption, ASHES fluid chlorinity did not change significantly. High gas contents reflect magma degassing throughout the entire history of fluid sampling at Axial. Spatial and temporal patterns of vent fluid chemistry will be presented.

  4. Imaging of cerebellopontine angle lesions: an update. Part 2: intra-axial lesions, skull base lesions that may invade the CPA region, and non-enhancing extra-axial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Bonneville, Fabrice; Chiras, Jacques [Pitie-Salpetriere Hospital, Department of Neuroradiology, Paris (France); Savatovsky, Julien [Adolphe de Rothschild Foundation, Department of Radiology, Paris (France)

    2007-11-15

    Computed tomography (CT) and magnetic resonance (MR) imaging reliably demonstrate typical features of vestibular schwannomas or meningiomas in the vast majority of mass lesions responsible for cerebellopontine angle (CPA) syndrome. However, a large variety of unusual lesions can also be encountered in the CPA. Covering the entire spectrum of lesions potentially found in the CPA, these articles explain the pertinent neuroimaging features that radiologists need to know to make clinically relevant diagnoses in these cases, including data from diffusion- and perfusion-weighted imaging or MR spectroscopy, when available. A diagnostic algorithm based on the lesion's site of origin, shape and margins, density, signal intensity and contrast material uptake is also proposed. Non-enhancing extra-axial CPA masses are cystic (epidermoid cyst, arachnoid cyst, neurenteric cyst) or contain fat (dermoid cyst, lipoma). Tumours can also extend into the CPA by extension from the skull base (paraganglioma, chondromatous tumours, chordoma, cholesterol granuloma, endolymphatic sac tumour). Finally, brain stem or ventricular tumours can present with a significant exophytic component in the CPA that may be difficult to differentiate from an extra-axial lesion (lymphoma, hemangioblastoma, choroid plexus papilloma, ependymoma, glioma, medulloblastoma, dysembryoplastic neuroepithelial tumour). (orig.)

  5. Fully automatic measurements of axial vertebral rotation for assessment of spinal deformity in idiopathic scoliosis

    Science.gov (United States)

    Forsberg, Daniel; Lundström, Claes; Andersson, Mats; Vavruch, Ludvig; Tropp, Hans; Knutsson, Hans

    2013-03-01

    Reliable measurements of spinal deformities in idiopathic scoliosis are vital, since they are used for assessing the degree of scoliosis, deciding upon treatment and monitoring the progression of the disease. However, commonly used two dimensional methods (e.g. the Cobb angle) do not fully capture the three dimensional deformity at hand in scoliosis, of which axial vertebral rotation (AVR) is considered to be of great importance. There are manual methods for measuring the AVR, but they are often time-consuming and related with a high intra- and inter-observer variability. In this paper, we present a fully automatic method for estimating the AVR in images from computed tomography. The proposed method is evaluated on four scoliotic patients with 17 vertebrae each and compared with manual measurements performed by three observers using the standard method by Aaro-Dahlborn. The comparison shows that the difference in measured AVR between automatic and manual measurements are on the same level as the inter-observer difference. This is further supported by a high intraclass correlation coefficient (0.971-0.979), obtained when comparing the automatic measurements with the manual measurements of each observer. Hence, the provided results and the computational performance, only requiring approximately 10 to 15 s for processing an entire volume, demonstrate the potential clinical value of the proposed method.

  6. Electrical Impedance Tomography Technology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Electrical Impendance Tomography (EIT) utilizes a series of electrodes in a circumferential band-like device feeding these signals to a portable computer that...

  7. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature th...

  8. Computed tomography of the prostate.

    Science.gov (United States)

    Van Engelshoven, J M; Kreel, L

    1979-02-01

    The conventional anatomy of the prostate is reviewed and the computed tomography (CT) anatomy described and illustrated. The results of 55 "normal" cases were analyzed for size and relationship to the symphysis pubis, retropubic space, and bladder, as shown on CT sections correlating the features with age and possible urinary symptoms. Attention is also drawn to the differences between phleboliths and prostatic calcification. Computed tomography is an effective method of demonstrating the prostate and surrounding structures and of assessing prostatic enlargement.

  9. Axially extended-volume C-arm CT using a reverse helical trajectory in the interventional room.

    Science.gov (United States)

    Yu, Zhicong; Maier, Andreas; Lauritsch, Gunter; Vogt, Florian; Schonborn, Manfred; Kohler, Christoph; Hornegger, Joachim; Noo, Frederic

    2015-01-01

    C-arm computed tomography (CT) is an innovative technique that enables a C-arm system to generate 3-D images from a set of 2-D X-ray projections. This technique can reduce treatment-related complications and may improve interventional efficacy and safety. However, state-of-the-art C-arm systems rely on a circular short scan for data acquisition, which limits coverage in the axial direction. This limitation was reported as a problem in hepatic vascular interventions. To solve this problem, as well as to further extend the value of C-arm CT, axially extended-volume C-arm CT is needed. For example, such an extension would enable imaging the full aorta, the peripheral arteries or the spine in the interventional room, which is currently not feasible. In this paper, we demonstrate that performing long object imaging using a reverse helix is feasible in the interventional room. This demonstration involved developing a novel calibration method, assessing geometric repeatability, implementing a reconstruction method that applies to real reverse helical data, and quantitatively evaluating image quality. Our results show that: 1) the reverse helical trajectory can be implemented and reliably repeated on a multiaxis C-arm system; and 2) a long volume can be reconstructed with satisfactory image quality using reverse helical data.

  10. Common approach for compensation of axial motion artifacts in swept-source OCT and dispersion in Fourier-domain OCT.

    Science.gov (United States)

    Hillmann, Dierck; Bonin, Tim; Lührs, Christian; Franke, Gesa; Hagen-Eggert, Martin; Koch, Peter; Hüttmann, Gereon

    2012-03-12

    Swept-source optical coherence tomography (SS-OCT) is sensitive to sample motion during the wavelength sweep, which leads to image blurring and image artifacts. In line-field and full-field SS-OCT parallelization is achieved by using a line or area detector, respectively. Thus, approximately 1000 lines or images at different wavenumbers are acquired. The sweep duration is identically with the acquisition time of a complete B-scan or volume, rendering parallel SS-OCT more sensitive to motion artifacts than scanning OCT. The effect of axial motion on the measured spectra is similar to the effect of non-balanced group velocity dispersion (GVD) in the interferometer arms. It causes the apparent optical path lengths in the sample arm to vary with the wavenumber. Here we propose the cross-correlation of sub-bandwidth reconstructions (CCSBR) as a new algorithm that is capable of detecting and correcting the artifacts induced by axial motion in line-field or full-field SS-OCT as well as GVD mismatch in any Fourier-domain OCT (FD-OCT) setup. By cross-correlating images which were reconstructed from a limited spectral range of the interference signal, a phase error is determined which is used to correct the spectral modulation prior to the calculation of the A-scans. Performance of the algorithm is demonstrated on in vivo full-field SS-OCT images of skin and scanning FD-OCT of skin and retina. PMID:22418560

  11. Seismic attenuation tomography in frequency domain and its application to engineering

    Institute of Scientific and Technical Information of China (English)

    赵永贵[1; 李勤[2; 郭鸿[3; 靳洪晓[4; 王超凡[5

    2000-01-01

    Seismic tomography is a new geophysical technique being developed to meet the needs of mining and engineering projects. Attenuation tomography, as one kind of seismic tomography technique, is a powerful prospecting tool for determining structure defaults such as fault, broken zone, and hidden voids, but it has been little discussed up to now. Its principle and applications are presented in detail. Attenuation tomography technology includes the following main points. First, on the basis of spectrum analysis to each seismic record, geometric correction is conducted, then common source parameters are introduced into common shot records in order to keep absorption effect of the geological media separate from source spectrum influence. Finally, an equation set is obtained which consists of absorption coefficients, common source parameters and energy field data observed. This technique can be employed together with velocity tomography to provide more evidence for engineering and geological diagnosis. Its appl

  12. Seismic attenuation tomography in frequency domain and its application to engineering

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Seismic tomography is a new geophysical technique being developed to meet the needs of mining and engineering projects. Attenuation tomography, as one kind of seismic tomography technique, is a powerful prospecting tool for determining structure defaults such as fault, broken zone, and hidden voids, but it has been little discussed up to now. Its principle and applications are presented in detail. Attenuation tomography technology includes the following main points. First, on the basis of spectrum analysis to each seismic record, geometric correction is conducted, then common source parameters are introduced into common shot records in order to keep absorption effect of the geological media separate from source spectrum influence. Finally, an equation set is obtained which consists of absorption coefficients, common source parameters and energy field data observed. This technique can be employed together with velocity tomography to provide more evidence for engineering and geological diagnosis. Its applications to exploration of mineral and engineering have led to satisfactory results.

  13. Depth Compensated Spectral Domain Optical Coherence Tomography via Digital Compensation

    CERN Document Server

    Boroomand, Ameneh; Shafiee, Mohammad Javad; Bizheva, Kostadinka; Wong, Alexander

    2015-01-01

    Spectral Domain Optical Coherence Tomography (SD-OCT) is a well-known imaging modality which allows for \\textit{in-vivo} visualization of the morphology of different biological tissues at cellular level resolutions. The overall SD-OCT imaging quality in terms of axial resolution and Signal-to-Noise Ratio (SNR) degrades with imaging depth, while the lateral resolution degrades with distance from the focal plane. This image quality degradation is due both to the design of the SD-OCT imaging system and the optical properties of the imaged object. Here, we present a novel Depth Compensated SD-OCT (DC-OCT) system that integrates a Depth Compensating Digital Signal Processing (DC-DSP) module to improve the overall imaging quality via digital compensation. The designed DC-DSP module can be integrated to any SD-OCT system and is able to simultaneously compensate for the depth-dependent loss of axial and lateral resolutions, depth-varying SNR, as well as sidelobe artifact for improved imaging quality. The integrated D...

  14. Oblique reconstruction of the cruciate ligaments on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Hidetoshi; Nishino, Koshi; Koga, Masayuki; Kitakata, Akira; Deya, Keizo; Nakagawa, Hiroto

    1984-12-01

    Optimal positioning where the entire longitudinal axis of the cruciate ligaments could be demonstrated on computed tomography was discovered by using an amputated knee and was applied clinically. To demonstrate the anterior cruciate ligament, the patient was positioned on the table with the hip flexed, abducted, externally rotated and knee flexed at a 110-140 degrees angle. For the posterior cruciate ligament, the patient was placed in a prone position on the table with the knee flexed at a 50 degrees angle. These positions, especially the one for the anterior cruciate ligament, were difficult for some patients with gonalgia or limited range of motion. Reconstruction in the oblique planes was studied for those patients by using an amputated knee and quasi-ligament made of gum. Clinically, an axial image was obtained by the simple position of the patient lying prone on the table with knee extended. Oblique reconstruction was made from the axial images and this reconstructed image also demonstrated the entire longitudinal axis of the ligament. The rupture of the cruciate ligaments could be assessed by the reconstructed image in the oblique plane. (author).

  15. Bone changes of mandibular condyle using cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Un; Kim, Hyung Seop; Song, Ju Seop; Kim, Kyoung A; Koh, Kwang Joon [Chonbuk National Univ., Chonju (Korea, Republic of)

    2007-09-15

    To assess bone changes of mandibular condyle using cone beam computed tomography (CBCT) in temporomandibualr disorder (TMD) patients. 314 temporomandibular joints (TMJs) images of 163 TMD patients were examined at the Department of Oral and Maxillofacial Radiology, Chonbuk National University. The images were obtained by PSR9000N (Asahi Roentgen Co., Japan) and reconstructed by using Asahivision software (Asahi Roentgen Co., Japan). The CBCT images were examined three times with four weeks interval by three radiologists. Bone changes of mandibular condyle such as flattening, sclerosis, erosion and osteophyte formation were observed in sagittal, axial, coronal and 3 dimensional images of the mandibular condyle. The statistical analysis was performed using SPSS 12.0. Intra-and interobserver agreement were performed by 3 radiologists without the knowledge of clinical information. Osteopathy (2.9%) was found more frequently on anterior surface of the mandibular condyle. Erosion (31.8%) was found more frequently on anterior surface of the mandibular condyle. The intraobserver agreement was good to excellent (k=0.78{sub 0}.84), but interobserver agreement was fair (k=0.45). CBCT can provide high qualified images of bone changes of the TMJ with axial, coronal and 3 dimensional images.

  16. Multiphoton tomography of astronauts

    Science.gov (United States)

    König, Karsten; Weinigel, Martin; Pietruszka, Anna; Bückle, Rainer; Gerlach, Nicole; Heinrich, Ulrike

    2015-03-01

    Weightlessness may impair the astronaut's health conditions. Skin impairments belong to the most frequent health problems during space missions. Within the Skin B project, skin physiological changes during long duration space flights are currently investigated on three European astronauts that work for nearly half a year at the ISS. Measurements on the hydration, the transepidermal water loss, the surface structure, elasticity and the tissue density by ultrasound are conducted. Furthermore, high-resolution in vivo histology is performed by multiphoton tomography with 300 nm spatial and 200 ps temporal resolution. The mobile certified medical tomograph with a flexible 360° scan head attached to a mechano-optical arm is employed to measure two-photon autofluorescence and SHG in the volar forearm of the astronauts. Modification of the tissue architecture and of the fluorescent biomolecules NAD(P)H, keratin, melanin and elastin are detected as well as of SHG-active collagen. Thinning of the vital epidermis, a decrease of the autofluoresence intensity, an increase in the long fluorescence lifetime, and a reduced skin ageing index SAAID based on an increased collagen level in the upper dermis have been found. Current studies focus on recovery effects.

  17. Solar tomography adaptive optics.

    Science.gov (United States)

    Ren, Deqing; Zhu, Yongtian; Zhang, Xi; Dou, Jiangpei; Zhao, Gang

    2014-03-10

    Conventional solar adaptive optics uses one deformable mirror (DM) and one guide star for wave-front sensing, which seriously limits high-resolution imaging over a large field of view (FOV). Recent progress toward multiconjugate adaptive optics indicates that atmosphere turbulence induced wave-front distortion at different altitudes can be reconstructed by using multiple guide stars. To maximize the performance over a large FOV, we propose a solar tomography adaptive optics (TAO) system that uses tomographic wave-front information and uses one DM. We show that by fully taking advantage of the knowledge of three-dimensional wave-front distribution, a classical solar adaptive optics with one DM can provide an extra performance gain for high-resolution imaging over a large FOV in the near infrared. The TAO will allow existing one-deformable-mirror solar adaptive optics to deliver better performance over a large FOV for high-resolution magnetic field investigation, where solar activities occur in a two-dimensional field up to 60'', and where the near infrared is superior to the visible in terms of magnetic field sensitivity.

  18. [Optical coherence tomography].

    Science.gov (United States)

    von Braunmühl, T

    2015-07-01

    Optical coherence tomography (OCT) was introduced in the 1990s in dermatology and is nowadays established as a noninvasive high-resolution technique for the in vivo evaluation of the skin. To date several studies have been successfully demonstrated the application of OCT for various dermatological questions. The main indication for OCT in the daily practice is the noninvasive diagnosis of nonmelanoma skin cancer such as actinic keratosis and basal cell carcinoma. OCT has also been shown to be a valuable tool in treatment monitoring and evaluation of therapeutic success of noninvasive treatment strategies like topical immune modulators or photodynamic treatment. Other potential applications for OCT include inflammatory diseases, microbial or parasitic infestations of the skin, e.g. scabies mites or onychomycosis. In recent years high-definition OCT devices have been developed that can potentially be used for the evaluation of melanocytic lesions and, due to the higher resolution, for the visualization of intrafollicular demodex mites. Furthermore different commercially available devices offer-in addition to the cross-sectional images-a fast-generated horizontal (en face) imaging mode. With respect to resolution and penetration depth the OCT technique is taking a middle position in comparison to other noninvasive imaging devices in dermatology such as sonography and reflectance confocal microscopy. PMID:25809459

  19. Computed tomography apparatus

    International Nuclear Information System (INIS)

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  20. Use of a coccygeal axial pattern flap for reconstruction following tumour excision in a cat.

    Science.gov (United States)

    Montinaro, Vincenzo; Massari, Federico; Romanelli, Giorgio

    2015-04-01

    A 6-year-old male castrated Chartreux cat was referred for recurrence of an injection site sarcoma at the base of the tail 7 months after the initial surgery. Upon presentation, the physical examination was unremarkable except for a non-painful, subcutaneous mass, 2 cm in diameter, firmly attached to the underlying tissue on the left lateral side of the tail base. Complete blood count, biochemistry and urinalysis were within normal limits; thoracic radiographs and abdominal ultrasound showed no evidence of metastatic disease. After removing the mass with 3 cm margins laterally and two deep fascial planes, the defect was reconstructed after tail amputation using a coccygeal axial pattern flap based on the lateral coccygeal arteries and veins. There were no complications with wound healing and the only visible change was a difference in hair coat direction at the 1 month re-check. This is the first report to describe the utility and feasibility of the coccygeal axial pattern flap to reconstruct a large cutaneous defect over the caudodorsal pelvic region in a cat. PMID:24899050

  1. Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gaia, Bruno Felipe [University of Sao Paulo (USP), SP (Brazil). Dental School. Stomatology Dept.; Sales, Marcelo Augusto Oliveira de [University of Paraiba (UFPB), Joao Pessoa, PB (Brazil). Dental School. Dept. of Radiology; Perrella, Andreia; Fenyo-Pereira, Marlene; Cavalcanti, Marcelo Gusmao Paraiso, E-mail: mgpcaval@usp.b [University of Sao Paulo (USP), SP (Brazil). Dental School. Dept. of Radiology

    2011-07-15

    There are many studies that compare the accuracy of multislice (MSCT) and cone beam (CBCT) computed tomography for evaluations in the maxillofacial region. However, further studies comparing both acquisition techniques for the evaluation of simulated mandibular bone lesions are needed. The aim of this study was to compare the accuracy of MSCT and CBCT in the diagnosis of simulated mandibular bone lesions by means of cross sectional images and axial/MPR slices. Lesions with different dimensions, shape and locularity were produced in 15 dry mandibles. The images were obtained following the cross sectional and axial/MPR (Multiplanar Reconstruction) imaging protocols and were interpreted independently. CBCT and MSCT showed similar results in depicting the percentage of cortical bone involvement, with great sensitivity and specificity (p < 0.005). There were no significant intra- or inter-examiner differences between axial/MPR images and cross sectional images with regard to sensitivity and specificity. CBCT showed results similar to those of MSCT for the identification of the number of simulated bone lesions. Cross sectional slices and axial/MPR images presented high accuracy, proving useful for bone lesion diagnosis. (author)

  2. Doppler optical coherence microscopy and tomography applied to inner ear mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Page, Scott; Freeman, Dennis M. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Ghaffari, Roozbeh [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States)

    2015-12-31

    While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

  3. Helical computed tomography-multiplanar reconstruction for diagnosis of biliary tract diseases

    Energy Technology Data Exchange (ETDEWEB)

    Katsuki, Yusuke; Nakazawa, Saburo; Yoshino, Junji; Inui, Kazuo; Wakabayashi, Takao; Okushima, Kazumu; Miyoshi, Hironao; Nakamura, Yuta; Etou, Nao [Fujita Health Univ., Nagoya (Japan). Second Teaching Hospital

    2000-12-01

    Multiplanar reconstruction (MPR) of helical computed tomography (HCT) was performed on 54 patients, including 27 patients with obstructive jaundice, and its usefulness in diagnosing biliary tract disease was evaluated. Ultrasonography (US) was also performed in all patients. HCT-MPR was able to delineated the upper, middle and lower bile duct in 100%, 100% and 98.1% of the cases, respectively. Biliary stenosis was diagnosed by HCT-MPR with an accuracy of 96.3%. The differential diagnosis of biliary stenosis was established correctly with an accuracy of 63.0% using US, compared with 83.3% using axial images of HCT (HCT-Axial). However, the diagnostic accuracy for rate of choledocholithiasis was 87.5% with HCT-MPR, 95.8% with HCT-Axial, and 76% with US. The overall accuracy of HCT-MPR was 88.9% in case of obstructive jaundice. The result was superior to that obtained with HCT-Axial (81.5%). In conclusion, HCT-MPR is useful for follow-up examination after ultrasonography in patients suspected of having biliary tract diseases. (author)

  4. Modelling larval transport in a axial convergence front

    Science.gov (United States)

    Robins, P.

    2010-12-01

    Marine larvae exhibit different vertical swimming behaviours, synchronised by factors such as tidal currents and daylight, in order to aid retention near the parent populations and hence promote production, avoid predation, or to stimulate digestion. This paper explores two types of larval migration in an estuarine axial convergent front which is an important circulatory mechanism in many coastal regions where larvae are concentrated. A parallelised, three-dimensional, ocean model was applied to an idealised estuarine channel which was parameterised from observations of an axial convergent front which occurs in the Conwy Estuary, U.K. (Nunes and Simpson, 1985). The model successfully simulates the bilateral cross-sectional recirculation of an axial convergent front, which has been attributed to lateral density gradients established by the interaction of the lateral shear of the longitudinal currents with the axial salinity gradients. On the flood tide, there is surface axial convergence whereas on the ebb tide, there is (weaker) surface divergence. Further simulations with increased/decreased tidal velocities and with stronger/weaker axial salinity gradients are planned so that the effects of a changing climate on the secondary flow can be understood. Three-dimensional Lagrangian Particle Tracking Models (PTMs) have been developed which use the simulated velocity fields to track larvae in the estuarine channel. The PTMs take into account the vertical migrations of two shellfish species that are commonly found in the Conwy Estuary: (i) tidal migration of the common shore crab (Carcinus maenas) and (ii), diel (daily) migration of the Great scallop (Pecten maximus). These migration behaviours are perhaps the most widespread amongst shellfish larvae and have been compared with passive (drifting) particles in order to assess their relative importance in terms of larval transport. Preliminary results suggest that the net along-estuary dispersal over a typical larval

  5. Master/slave interferometry - ideal tool for coherence revival swept source optical coherence tomography.

    Science.gov (United States)

    Bradu, Adrian; Rivet, Sylvain; Podoleanu, Adrian

    2016-07-01

    In this paper, we demonstrate that the master slave (MS) interferometry method can significantly simplify the practice of coherence revival swept source optical coherence tomography (OCT) technique. Previous implementations of the coherence revival technique required considerable resources on dispersion compensation and data resampling. The total tolerance of the MS method to nonlinear tuning, to dispersion in the interferometer and to dispersion due to the laser cavity, makes the MS ideally suited to the practice of coherence revival. In addition, enhanced versatility is allowed by the MS method in displaying shorter axial range images than that determined by the digital sampling of the data. This brings an immediate improvement in the speed of displaying cross-sectional images at high rates without the need of extra hardware such as graphics processing units or field programmable gate arrays. The long axial range of the coherence revival regime is proven with images of the anterior segment of healthy human volunteers. PMID:27446682

  6. Macular thickness evaluation using the optical coherence tomography in normal Indian eyes.

    Directory of Open Access Journals (Sweden)

    Tewari Hem

    2004-01-01

    Full Text Available PURPOSE: To determine the normative values for macular thickness and volume by Optical Coherence Tomography (OCT 3 in healthy Indian subjects. METHODS: The macula of 170 consecutive, randomly selected normal subjects was imaged on OCT 3 in this cross-sectional study. OCT parameters of macular thickness were analysed with baseline variables including age, gender, axial length and refractive error. RESULTS: The average foveal thickness in the population under study was 149.16 +/- 21.15 micro. Macular thickness and volume parameters of OCT correlated significantly (Pearson′s Correlation coefficient with age (r=0.23, P<0.01, but not with gender, axial length and refraction. CONCLUSIONS: The macular thickness and volume parameters have a significant correlation with age. This normative database of macular thickness by OCT in Indian eyes may be a useful guideline for management and further research in diseases of the macula and glaucoma.

  7. Master/slave interferometry – ideal tool for coherence revival swept source optical coherence tomography

    Science.gov (United States)

    Bradu, Adrian; Rivet, Sylvain; Podoleanu, Adrian

    2016-01-01

    In this paper, we demonstrate that the master slave (MS) interferometry method can significantly simplify the practice of coherence revival swept source optical coherence tomography (OCT) technique. Previous implementations of the coherence revival technique required considerable resources on dispersion compensation and data resampling. The total tolerance of the MS method to nonlinear tuning, to dispersion in the interferometer and to dispersion due to the laser cavity, makes the MS ideally suited to the practice of coherence revival. In addition, enhanced versatility is allowed by the MS method in displaying shorter axial range images than that determined by the digital sampling of the data. This brings an immediate improvement in the speed of displaying cross-sectional images at high rates without the need of extra hardware such as graphics processing units or field programmable gate arrays. The long axial range of the coherence revival regime is proven with images of the anterior segment of healthy human volunteers. PMID:27446682

  8. Magnetic resonance tomography in confirmed multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Uhlenbrock, D.; Dickmann, E.; Beyer, H.K.; Gehlen, W.

    1985-03-01

    The authors report on 21 cases of confirmed multiple sclerosis examined by both CT and magnetic resonance tomography. To safeguard the results, strict criteria were applied in accordance with the suggestions made by neurological work teams. Pathological lesions were seen in 20 patients; the MR image did not reveal anything abnormal in one case. On the average, 10.3 lesions were seen in the MR tomogram, whereas CT images showed on the average only 2.1 foci. The size and number of lesions in the MR tomogram were independent of the duration of the disease, the presented clinical symptoms, or the type of treatment at the time of examination. Evidently the sensitivity of MR tomography is very high in MS patients, but it has not yet been clarified to what extent this applies also to the specificity. Further research is mandatory. First experiences made by us show that lesions of a similar kind can also occur in diseases such as malignant lymphoma involving the brain, in vitamin B 12 deficiency syndrome, or encephalitis, and can become manifest in the MR tomogram.

  9. The anomalous transport of axial charge: topological vs non-topological fluctuations

    CERN Document Server

    Iatrakis, Ioannis; Yin, Yi

    2015-01-01

    Axial charge imbalance is an essential ingredient in novel effects associated with chiral anomaly such as chiral magnetic effects (CME). In a non-Abelian plasma with chiral fermions, local axial charge can be generated a) by topological fluctuations which would create domains with non-zero winding number b) by conventional non-topological thermal fluctuations. We provide a holographic evaluations of medium's response to dynamically generated axial charge density in hydrodynamic limit and examine if medium's response depends on the microscopic origins of axial charge imbalance. We show a local domain with non-zero winding number would induce a non-dissipative axial current due to chiral anomaly. We illustrate holographically that a local axial charge imbalance would be damped out with the damping rate related to Chern-Simon diffusive constant. By computing chiral magnetic current in the presence of dynamically generated axial charge density, we found that the ratio of CME current over the axial charge density ...

  10. Reconstruction of velocity fields in electromagnetic flow tomography.

    Science.gov (United States)

    Lehtikangas, Ossi; Karhunen, Kimmo; Vauhkonen, Marko

    2016-06-28

    Electromagnetic flow meters (EMFMs) are the gold standard in measuring flow velocity in process industry. The flow meters can measure the mean flow velocity of conductive liquids and slurries. A drawback of this approach is that the velocity field cannot be determined. Asymmetric axial flows, often encountered in multiphase flows, pipe elbows and T-junctions, are problematic and can lead to serious systematic errors. Recently, electromagnetic flow tomography (EMFT) has been proposed for measuring velocity fields using several coils and a set of electrodes attached to the surface of the pipe. In this work, a velocity field reconstruction method for EMFT is proposed. The method uses a previously developed finite-element-based computational forward model for computing boundary voltages and a Bayesian framework for inverse problems. In the approach, the vz-component of the velocity field along the longitudinal axis of the pipe is estimated on the pipe cross section. Different asymmetric velocity fields encountered near pipe elbows, solids-in-water flows in inclined pipes and in stratified or multiphase flows are tested. The results suggest that the proposed reconstruction method could be used to estimate velocity fields in complicated pipe flows in which the conventional EMFMs have limited accuracy. This article is part of the themed issue 'Supersensing through industrial process tomography'. PMID:27185961

  11. Reconstruction of axisymmetric strain distributions via neutron strain tomography

    International Nuclear Information System (INIS)

    Predicting the behaviour of structural components under a particular set of loading conditions requires knowledge of the residual elastic strain distribution throughout the bulk of these components. Characterising the 3D strain state at any particular point involves the measurement of six independent components which make up the second order strain tensor. Mapping the complete strain distribution throughout large volumes thus presents significant practical challenges. One possible solution to this problem is to reconstruct the 3D variation of strain components using tomographic techniques. The basic principle underpinning this idea is that the multi-component strain tensor can be reconstructed from a redundant set of lower order projection data. Here we demonstrate this fundamental concept for two samples: a shrink fit ‘ring-and-plug’ sample, and a spray-quenched circular cylinder, both possessing axially symmetric internal strain distribution. We present and contrast different approaches to the strain tomography problem. The methods described here can also be readily applied to high-energy X-ray diffraction measurements and represent an important step toward developing the tomographic reconstruction framework for strain tensor distributions of arbitrary complexity. The major benefit of neutron strain tomography is that the incident beam flux is utilised more fully, greatly reducing the data collection times. Using micro-channel plate (MCP) neutron detectors, a spatial resolution of the order of 0.1 mm can be achieved .

  12. Positron Emission Tomography with Three-Dimensional Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of `mobile pixels`, which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs.

  13. Computed tomography findings of paracoccidiodomycosis in musculoskeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Lima Junior, Francisco Valtenor Araujo; Savarese, Leonor Garbin; Monsignore, Lucas Moretti; Martinez, Roberto; Nogueira-Barbosa, Marcello Henrique, E-mail: fvaltenor@gmail.com [Universidade de Sao Paulo (FM/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina

    2015-01-15

    Objective: to evaluate musculoskeletal involvement in paracoccidioidomycosis at computed tomography. Materials and methods: development of a retrospective study based on a review of radiologic and pathologic reports in the institution database. Patients with histopathologically confirmed musculoskeletal paracoccidioidomycosis and submitted to computed tomography were included in the present study. The imaging findings were consensually described by two radiologists. In order to avoid bias in the analysis, one patient with uncountable bone lesions was excluded from the study. Results: a total of seven patients were included in the present study. A total of 18 bone lesions were counted. The study group consisted of 7 patients. A total number of 18 bone lesions were counted. Osteoarticular lesions were the first manifestation of the disease in four patients (57.14%). Bone lesions were multiple in 42.85% of patients. Appendicular and axial skeleton were affected in 85.71% and 42.85% of cases, respectively. Bone involvement was characterized by well-demarcated osteolytic lesions. Marginal osteosclerosis was identified in 72.22% of the lesions, while lamellar periosteal reaction and soft tissue component were present in 5.55% of them. One patient showed multiple small lesions with bone sequestra. Conclusion: paracoccidioidomycosis can be included in the differential diagnosis of either single or multiple osteolytic lesions in young patients even in the absence of a previous diagnosis of pulmonary or visceral paracoccidioidomycosis. (author)

  14. Use of cone beam computed tomography in periodontology.

    Science.gov (United States)

    Acar, Buket; Kamburoğlu, Kıvanç

    2014-05-28

    Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography (CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correct indications considering the necessity and the potential hazards of the examination.

  15. Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Pier Alberto Testoni

    2007-01-01

    Full Text Available Optical coherence tomography (OCT is an optical imaging modality that performs high-resolution, cross-sectional, subsurface tomographic imaging of the microstructure of tissues. The physical principle of OCT is similar to that of B-mode ultrasound imaging, except that it uses infrared light waves rather than acoustic waves. The in vivo resolution is 10–25 times better (about 10 µm than with high-frequency ultrasound imaging, but the depth of penetration is limited to 1–3 mm, depending on tissue structure, depth of focus of the probe used, and pressure applied to the tissue surface. In the last decade, OCT technology has evolved from an experimental laboratory tool to a new diagnostic imaging modality with a wide spectrum of clinical applications in medical practice, including the gastrointestinal tract and pancreatico-biliary ductal system. OCT imaging from the gastrointestinal tract can be done in humans by using narrow-diameter, catheter-based probes that can be inserted through the accessory channel of either a conventional front-view endoscope, for investigating the epithelial structure of the gastrointestinal tract, or a side-view endoscope, inside a standard transparent ERCP (endoscopic retrograde cholangiopancreatography catheter, for investigating the pancreatico-biliary ductal system. The esophagus and esophagogastric junction have been the most widely investigated organs so far; more recently, duodenum, colon, and the pancreatico-biliary ductal system have also been extensively investigated. OCT imaging of the gastrointestinal wall structure is characterized by a multiple-layer architecture that permits an accurate evaluation of the mucosa, lamina propria, muscularis mucosae, and part of the submucosa. The technique may therefore be used to identify preneoplastic conditions of the gastrointestinal tract, such as Barrett's epithelium and dysplasia, and evaluate the depth of penetration of early-stage neoplastic lesions. OCT imaging

  16. Instability of meridional axial system in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Sharif, M.; Yousaf, Z. [University of the Punjab, Department of Mathematics, Lahore (Pakistan)

    2015-05-15

    We analyze the dynamical instability of a non-static reflection axial stellar structure by taking into account the generalized Euler equation in metric f(R) gravity. Such an equation is obtained by contracting the Bianchi identities of the usual anisotropic and effective stress-energy tensors, which after using a radial perturbation technique gives a modified collapse equation. In the realm of the R + εR{sup n} gravity model, we investigate instability constraints at Newtonian and post-Newtonian approximations. We find that the instability of a meridional axial self-gravitating system depends upon the static profile of the structure coefficients, while f(R) extra curvature terms induce the stability of the evolving celestial body. (orig.)

  17. Buckling Imperfection Sensitivity of Axially Compressed Orthotropic Cylinders

    Science.gov (United States)

    Schultz, Marc R.; Nemeth, Michael P.

    2010-01-01

    Structural stability is a major consideration in the design of lightweight shell structures. However, the theoretical predictions of geometrically perfect structures often considerably over predict the buckling loads of inherently imperfect real structures. It is reasonably well understood how the shell geometry affects the imperfection sensitivity of axially compressed cylindrical shells; however, the effects of shell anisotropy on the imperfection sensitivity is less well understood. In the present paper, the development of an analytical model for assessing the imperfection sensitivity of axially compressed orthotropic cylinders is discussed. Results from the analytical model for four shell designs are compared with those from a general-purpose finite-element code, and good qualitative agreement is found. Reasons for discrepancies are discussed, and potential design implications of this line of research are discussed.

  18. Effect of axial mixing on RDC and PSE columns performance

    CERN Document Server

    Bastani, D

    2001-01-01

    Using the experimental data obtained from two RDC columns at two different sizes (7.62 and 21.9 cm) and one PSE column with 21.5 cm size, the effect of axial mixing on the performance of these columns was studied. Comparison between the experimental and theoretical (neglecting the axial mixing) number of transfer units indicates that, this effect in PSE columns is more than RDC columns (400% and 200% respectively). These results show that this effect can increase the height of the PSE column up to 4 times for a specific efficiency. Also the results show that this effect is more in law interfacial tension systems, which shows no need of application of agitation facilities when these systems are used.

  19. Ultraviolet and infrared aspects of the axial anomaly. I

    International Nuclear Information System (INIS)

    The paper is the first part of a brief review of some perturbative aspects of the Adler-Bell-Jackiw axial anomaly, described in terms of ultraviolet and infrared behavior of the famous VVA triangle graph. Apart from a general overview of the diversified role played by the anomaly in quantum field theory and particle physics, an elementary introduction is presented to the subject of the anomaly, comprehensible to an uninitiated reader with only a basic background in quantum field theory. The ultraviolet aspects of the anomaly are stressed and the topics covered are the following: vector and axial-vector Ward identities for the VVA triangle graph; the anomaly and several ways to derive it, namely the symmetric momentum cut-off and shifting the integration variables in linearly divergent integrals; the Adler-Rosenberg argument; the Pauli-Villars method; and dimensional regularization. (author) 2 figs., 34 refs

  20. Regularized path integrals and anomalies -- U(1) axial gauge theory

    CERN Document Server

    Kopper, Christoph

    2011-01-01

    We analyse the origin of the Adler anomaly of axial U(1) gauge theory within the framework of regularized path integrals. Momentum or position space regulators allow for mathematically well-defined path integrals but violate local gauge symmetry. It is known how (nonanomalous) gauge symmetry can be recovered in the renormalized theory in this case [1]. Here we analyse U(1) axial gauge theory to show how the appearance of anomalies manifests itself in such a context. We show that the three-photon amplitude leads to a violation of the Slavnov-Taylor-Identities which cannot be restored on taking the UV limit in the renormalized theory. We point out that this fact is related to the nonanalyticity of this amplitude in the infrared region.

  1. Axial Ge/Si nanowire heterostructure tunnel FETs

    Energy Technology Data Exchange (ETDEWEB)

    Picraux, Sanuel T [Los Alamos National Laboratory; Daych, Shadi A [Los Alamos National Laboratory

    2010-01-01

    The vapor-liquid-solid (VLS) growth of semiconductor nanowires allows doping and composition modulation along their axis and the realization of axial 1 D heterostructures. This provides additional flexibility in energy band-edge engineering along the transport direction which is difficult to attain by planar materials growth and processing techniques. We report here on the design, growth, fabrication, and characterization of asymmetric heterostructure tunnel field-effect transistors (HTFETs) based on 100% compositionally modulated Si/Ge axial NWs for high on-current operation and low ambipolar transport behavior. We discuss the optimization of band-offsets and Schottky barrier heights for high performance HTFETs and issues surrounding their experimental realization. Our HTFET devices with 10 nm PECVD SiN{sub x} gate dielectric resulted in a measured current drive exceeding 100 {mu}A/{mu}m (I/{pi}D) and 10{sup 5} I{sub on}/I{sub off} ratios.

  2. Choroidal thinning in high myopia measured by optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Ikuno Y

    2013-05-01

    Full Text Available Yasushi Ikuno, Satoko Fujimoto, Yukari Jo, Tomoko Asai, Kohji NishidaDepartment of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, JapanPurpose: To investigate the rate of choroidal thinning in highly myopic eyes.Patients and methods: A retrospective observational study of 37 eyes of 26 subjects (nine males and 17 females, mean age 39.6 ± 7.7 years with high myopia but no pathologies who had undergone spectral domain optical coherence tomography and repeated the test 1 year later (1 ± 0.25 year at Osaka University Hospital, Osaka, Japan. Patients older than 50 years with visual acuity worse than 20/40 or with whitish chorioretinal atrophy involving the macula were excluded. Two masked raters measured the choroidal thicknesses (CTs at the foveda, 3 mm superiorly, inferiorly, temporally, and nasally on the images and averaged the values. The second examination was about 365 days after the baseline examination. The CT reduction per year (CTRPY was defined as (CT 1 year after - baseline CT/days between the two examinations × 365. The retinal thicknesses were also investigated.Results: The CTRPY at the fovea was −1.0 ± 22.0 µm (range –50.2 to 98.5 at the fovea, –6.5 ± 24.3 µm (range −65.8 to 90.2 temporally, –0.5 ± 22.3 µm (range –27.1 to 82.5 nasally, –9.7 ± 21.7 µm (range –40.1 to 60.1 superiorly, and –1.4 ± 25.5 µm (range –85.6 to 75.2 inferiorly. There were no significant differences in the CTRPY at each location (P = 0.34. The CT decreased significantly (P < 0.05 only superiorly. The superior CTRPY was negatively correlated with the axial length (P < 0.05. The retinal thickness at the fovea did not change. Stepwise analysis for CTRPY selected axial length (P = 0.04, R2 = 0.13 and age (P = 0.08, R2 = 0.21 as relevant factors.Conclusions: The highly myopic choroid might gradually thin and be affected by many factors. Location and axial length are key factors to regulate the rate of choroidal

  3. Donor disc attachment assessment with intraoperative spectral optical coherence tomography during descemet stripping automated endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Edward Wylegala

    2013-01-01

    Full Text Available Optical coherence tomography has already been proven to be useful for pre- and post-surgical anterior eye segment assessment, especially in lamellar keratoplasty procedures. There is no evidence for intraoperative usefulness of optical coherence tomography (OCT. We present a case report of the intraoperative donor disc attachment assessment with spectral-domain optical coherence tomography in case of Descemet stripping automated endothelial keratoplasty (DSAEK surgery combined with corneal incisions. The effectiveness of the performed corneal stab incisions was visualized directly by OCT scan analysis. OCT assisted DSAEK allows the assessment of the accuracy of the Descemet stripping and donor disc attachment.

  4. Defining and generating axial lines from street center lines for better understanding of urban morphologies

    OpenAIRE

    Xintao, Liu; Bin, Jiang

    2012-01-01

    Axial lines are defined as the longest visibility lines for representing individual linear spaces in urban environments. The least number of axial lines that cover the free space of an urban environment or the space between buildings constitute what is often called an axial map. This is a fundamental tool in space syntax, a theory developed by Bill Hillier and his colleagues for characterizing the underlying urban morphologies. For a long time, generating axial lines with help of some graphic...

  5. MRI of the axial skeletal manifestations of ankylosing spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Levine, D.S.; Forbat, S.M.; Saifuddin, A. E-mail: asaifuddin@aol.com

    2004-05-01

    Magnetic resonance imaging (MRI) is a valuable tool in the imaging and assessment of patients with ankylosing spondylitis. MRI can demonstrate the acute and chronic changes of sacroiliitis, osteitis, discovertebral lesions, disc calcifications and ossification and arthopathic lesions, which characterize the disease, as well as the complications, which include fracture and the rare cauda equina syndrome. This article reviews the range of MRI findings commonly seen within the axial skeleton in patients with this condition.

  6. Wilson Loop and the Treatment of Axial Gauge Poles

    OpenAIRE

    Joglekar, Satish D.; Misra, A.

    1999-01-01

    We consider the question of gauge invariance of the Wilson loop in the light of a new treatment of axial gauge propagator proposed recently based on a finite field-dependent BRS (FFBRS) transformation. We remark that as under the FFBRS transformation the vacuum expectation value of a gauge invariant observable remains unchanged, our prescription automatically satisfies the Wilson loop criterion. Further, we give an argument for {\\it direct} verification of the invariance of Wilson loop to O(g...

  7. The Electroweak Standard Model in the Axial Gauge

    CERN Document Server

    Dams, C; Dams, Chris; Kleiss, Ronald

    2004-01-01

    We derive the Feynman rules of the standard model in the axial gauge. After this we prove that the fields $\\phi_W$ and $\\phi_Z$ do not correspond to physical particles. As a consequence, these fields cannot appear as incoming or outgoing lines in Feynman graphs. We then calculate the contribution of these fields in the case of a particular decay mode of the top quark.

  8. Axial form factor of the nucleon at large momentum transfers

    CERN Document Server

    Anikin, I V; Offen, N

    2016-01-01

    Motivated by the emerging possibilities to study threshold pion electroproduction at large momentum transfers at Jefferson Laboratory following the 12 GeV upgrade, we provide a short theory summary and an estimate of the nucleon axial form factor for large virtualities in the $Q^2 = 1-10~\\text{GeV}^2$ range using next-to-leading order light-cone sum rules.

  9. Axial form factor of the nucleon at large momentum transfers

    Science.gov (United States)

    Anikin, I. V.; Braun, V. M.; Offen, N.

    2016-08-01

    Motivated by the emerging possibilities to study threshold pion electroproduction at large momentum transfers at Jefferson Laboratory following the 12 GeV upgrade, we provide a short theory summary and an estimate of the nucleon axial form factor for large virtualities in the Q2=1 - 10 GeV2 range using next-to-leading-order light-cone sum rules.

  10. Improvement of the axial buckling capability of elliptical cylindrical shells

    OpenAIRE

    Paschero, Maurizio

    2008-01-01

    A rather thorough and novel buckling analysis of an axially-loaded orthotropic circular cylindrical shell is formulated. The analysis assumes prebuckling rotations are negligible and uses a unique re-defining of the orthotropic material properties in terms of a so-called geometric mean isotropic (GMI) material. Closed-form expressions for the buckling stress in terms of cylinder geometry and orthotropic material properties are presented, the particular closed form depending on ...

  11. Axial anomaly, Dirac sea, and the chiral magnetic effect

    OpenAIRE

    Kharzeev, Dmitri E.

    2010-01-01

    Gribov viewed the axial anomaly as a manifestation of the collective motion of charged fermions with arbitrarily high momenta in the vacuum. In the presence of an external magnetic field and a chirality imbalance, this collective motion becomes directly observable in the form of the electric current - this is the chiral magnetic effect (CME). I give an elementary introduction into the physics of CME, and discuss some recent developments.

  12. Overview of the Axial Field Spectrometer in the ISR tunnel

    CERN Multimedia

    1980-01-01

    A view of the Axial Field Spectrometer – the last large experiment at the ISR. The horizontal top and vertical outer arrays of the uranium-scintillator hadron calorimeter are clear to be seen, with the blue cylindrical pole piece of the magnet just visible. The pipes that are visible in front of the pole piece are cryogenic feed pipes for the superconducting low-beta quadrupoles.

  13. Vacuum arc under axial magnetic fields: experimental and simulation research

    International Nuclear Information System (INIS)

    Axial magnetic field (AMF) technology is a most important control method of vacuum arc, particularly for high-current vacuum arcs in vacuum interrupters. In this paper, a review of the state of current research on vacuum arcs under AMF is presented. The major aspects of vacuum arc in an AMF such as arc voltage, the motion of cathode spots, and anode activities are discussed, and the most recent progress both of experimental and simulation research is presented. (topical review)

  14. Enhanced betatron X-rays from axially modulated plasma wakefields

    CERN Document Server

    Palastro, J P; Gordon, D

    2015-01-01

    In the cavitation regime of plasma-based accelerators, a population of high-energy electrons tailing the driver can undergo betatron motion. The motion results in X-ray emission, but the brilliance and photon energy are limited by the electrons' initial transverse coordinate. To overcome this, we exploit parametrically unstable betatron motion in a cavitated, axially modulated plasma. Theory and simulations are presented showing that the unstable oscillations increase both the total X-ray energy and average photon energy.

  15. Crushing modes of aluminium tubes under axial compression

    OpenAIRE

    Pled, Florent; Yan, Wenyi; Wen, Cui'e

    2014-01-01

    6 pages International audience A numerical study of the crushing of circular aluminium tubes with and without aluminium foam fillers has been carried out to investigate their buckling behaviours under axial compression. A crushing mode classification chart has been established for empty tubes. The influence of boundary conditions on crushing mode has also been investigated. The effect of foam filler on the crushing mode of tubes filled with foam was then examined. The predicted results ...

  16. Dynamics and statics of flexible axially symmetric shallow shells

    OpenAIRE

    J. Awrejcewicz; V. A. Krysko; I. V. Kravtsova

    2006-01-01

    In this work, we propose the method for the investigation of stochastic vibrations of deterministic mechanical systems represented by axially symmetric spherical shells. These structure members are widely used as sensitive elements of pressure measuring devices in various branches of measuring and control industry, machine design, and so forth. The proposed method can be easily extended for the investigation of shallow spherical shells, goffer-type membranes, and so on. T...

  17. Measurement of axial injection displacement with trim coil current unbalance

    Science.gov (United States)

    Covo, Michel Kireeff

    2014-08-01

    The Dee probe used for measuring internal radial beam intensity shows large losses inside the radius of 20 cm of the 88 in. cyclotron. The current of the top and bottom innermost trim coil 1 is unbalanced to study effects of the axial injection displacement. A beam profile monitor images the ion beam bunches, turn by turn. The experimental bunch center of mass position is compared with calculations of the magnetic mirror effect displacement and shows good agreement.

  18. Identification of material parameters using bi-axial machine

    OpenAIRE

    Flores, Paulo; de Montleau, P.; Mathonet, V.; Moureaux, P. (collab.); Habraken, Anne

    2004-01-01

    Experimental testing equipment is built in order to identify material parameters of complex phenomenological constitutive laws. This equipment consists in a bi-axial test machine able to perform plane strain and simple shear tests separately or simultaneously and a Miyauchi simple shear test device; an optical extensometer is used to identify the strain field. The article focus on the validation of the results of this new equipment by comparing with results obtained by standard machines and/o...

  19. Comparison of design methods for axially loaded buckets in sand

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2015-01-01

    A study of the present knowledge about the bucket resistance for axial loading was performed considering analytical and numerical design methods as well as physical models. A case study was performed with two bucket foundations of equal diameter, but different skirt lengths installed in dense sand...... of the static tensile resistance for a bucket foundation. Furthermore, the predicted tensile resistance can differ up to 12 times indicating that further analysis is needed approaching this issue....

  20. Report on the Dynamical Evolution of an Axially Symmetric Quasar Model

    Indian Academy of Sciences (India)

    N. J. Papadopoulos; N. D. Caranicolas

    2006-12-01

    The role of the angular momentum in the regular or chaotic character of motion in an axially symmetric quasar model is examined. It is found that, for a given value of the critical angular momentum , there are two values of the mass of the nucleus for which transition from regular to chaotic motion occurs. The [-] relationship shows a linear dependence for the time independent model and an exponential dependence for the evolving model. Both cases are explained using theoretical arguments together with some numerical evidence. The evolution of the orbits is studied, as mass is transported from the disk to the nucleus. The results are compared with the outcomes derived for galactic models with massive nuclei.

  1. AXIAL RATIO OF EDGE-ON SPIRAL GALAXIES AS A TEST FOR BRIGHT RADIO HALOS

    Energy Technology Data Exchange (ETDEWEB)

    Singal, J.; Jones, E.; Dunlap, H. [Physics Department, University of Richmond 28 Westhampton Way, Richmond, VA 23173 (United States); Kogut, A., E-mail: jsingal@richmond.edu [Code 665, NASA Goddard Space Flight Center Greenbelt, MD 20771 (United States)

    2015-01-20

    We use surface brightness contour maps of nearby edge-on spiral galaxies to determine whether extended bright radio halos are common. In particular, we test a recent model of the spatial structure of the diffuse radio continuum by Subrahmanyan and Cowsik which posits that a substantial fraction of the observed high-latitude surface brightness originates from an extended Galactic halo of uniform emissivity. Measurements of the axial ratio of emission contours within a sample of normal spiral galaxies at 1500 MHz and below show no evidence for such a bright, extended radio halo. Either the Galaxy is atypical compared to nearby quiescent spirals or the bulk of the observed high-latitude emission does not originate from this type of extended halo. (letters)

  2. Axial power monitoring uncertainty in the Savannah River Reactors

    International Nuclear Information System (INIS)

    The results of this analysis quantified the uncertainty associated with monitoring the Axial Power Shape (APS) in the Savannah River Reactors. Thermocouples at each assembly flow exit map the radial power distribution and are the primary means of monitoring power in these reactors. The remaining uncertainty in power monitoring is associated with the relative axial power distribution. The APS is monitored by seven sensors that respond to power on each of nine vertical Axial Power Monitor (APM) rods. Computation of the APS uncertainty, for the reactor power limits analysis, started with a large database of APM rod measurements spanning several years of reactor operation. A computer algorithm was used to randomly select a sample of APSs which were input to a code. This code modeled the thermal-hydraulic performance of a single fuel assembly during a design basis Loss-of Coolant Accident. The assembly power limit at Onset of Significant Voiding was computed for each APS. The output was a distribution of expected assembly power limits that was adjusted to account for the biases caused by instrumentation error and by measuring 7 points rather than a continuous APS. Statistical analysis of the final assembly power limit distribution showed that reducing reactor power by approximately 3% was sufficient to account for APS variation. This data confirmed expectations that the assembly exit thermocouples provide all information needed for monitoring core power. The computational analysis results also quantified the contribution to power limits of the various uncertainties such as instrumentation error

  3. Period of vibration of axially vibrating truly nonlinear rod

    Science.gov (United States)

    Cveticanin, L.

    2016-07-01

    In this paper the axial vibration of a muscle whose fibers are parallel to the direction of muscle compression is investigated. The model is a clamped-free rod with a strongly nonlinear elastic property. Axial vibration is described by a nonlinear partial differential equation. A solution of the equation is constructed for special initial conditions by using the method of separation of variables. The partial differential equation is separated into two uncoupled strongly nonlinear second order differential equations. Both equations, with displacement function and with time function are exactly determined. Exact solutions are given in the form of inverse incomplete and inverse complete Beta function. Using boundary and initial conditions, the frequency of vibration is obtained. It has to be mentioned that the determined frequency represents the exact analytic description for the axially vibrating truly nonlinear clamped-free rod. The procedure suggested in this paper is applied for calculation of the frequency of the longissimus dorsi muscle of a cow. The influence of elasticity order and elasticity coefficient on the frequency property is tested.

  4. HTS axial flux induction motor with analytic and FEA modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, S., E-mail: alexlee.zn@gmail.com; Fan, Y.; Fang, J.; Qin, W.; Lv, G.; Li, J.H.

    2013-11-15

    Highlights: •A high temperature superconductor axial flux induction motor and a novel maglev scheme are presented. •Analytic method and finite element method have been adopted to model the motor and to calculate the force. •Magnetic field distribution in HTS coil is calculated by analytic method. •An effective method to improve the critical current of HTS coil is presented. •AC losses of HTS coils in the HTS axial flux induction motor are estimated and tested. -- Abstract: This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested.

  5. Imaging results and TOF studies with axial PET detectors

    CERN Document Server

    Joram, Christian

    2013-01-01

    We have developed a fully operational PET demonstrator setup which allows true 3D reconstruction of the 511 keV photons and therefore leads to practically parallax free images. The AX-PET concept is based on thin 100 mm long scintillation crystals (LYSO), axially oriented and arranged in layers around the held of view. Layers of wavelength shifting plastic strips mounted in between the crystal layers give the axial coordinate. Both crystals and WLS strips are individually read out by G-APD (SiPM) photodetectors. The Fully scalable concept overcomes the dilemma of sensitivity versus spatial resolution which is inherent to classical PET designs. A demonstrator set-up based on two axial modules was exhaustively characterized using point-like sources, phantoms filled with radiotracer and finally rats and a mouse. The results entirely meet the performance expectations ( <2 mm FWHM in all three coordinates over the complete held of view) and also demonstrated the ability to include Compton interactions (inter-cr...

  6. Behavior of Unbonded Flexible Risers Subject to Axial Tension

    Institute of Scientific and Technical Information of China (English)

    任少飞; 唐文勇; 郭晋挺

    2014-01-01

    Owing to nonlinear contact problems with slip and friction, a lot of limiting assumptions are made when developing analytical models to simulate the behavior of an unbonded flexible riser. Meanwhile, in order to avoid convergence problems and excessive calculating time associated with running the detailed finite element (FE) model of an unbonded flexible riser, interlocked carcass and zeta layers with complicated cross section shapes are replaced by simple geometrical shapes (e.g. hollow cylindrical shell) with equivalent orthotropic materials. But the simplified model does not imply the stresses equivalence of these two layers. To solve these problems, based on ABAQUS/Explicit, a numerical method that is suitable for the detailed FE model is proposed. In consideration of interaction among all component layers, the axial stiffness of an eight-layer unbonded flexible riser subjected to axial tension is predicted. Compared with analytical and experimental results, it is shown that the proposed numerical method not only has high accuracy but also can substantially reduce the calculating time. In addition, the impact of the lay angle of helical tendons on axial stiffness is discussed.

  7. Axial and Centrifugal Compressor Mean Line Flow Analysis Method

    Science.gov (United States)

    Veres, Joseph P.

    2009-01-01

    This paper describes a method to estimate key aerodynamic parameters of single and multistage axial and centrifugal compressors. This mean-line compressor code COMDES provides the capability of sizing single and multistage compressors quickly during the conceptual design process. Based on the compressible fluid flow equations and the Euler equation, the code can estimate rotor inlet and exit blade angles when run in the design mode. The design point rotor efficiency and stator losses are inputs to the code, and are modeled at off design. When run in the off-design analysis mode, it can be used to generate performance maps based on simple models for losses due to rotor incidence and inlet guide vane reset angle. The code can provide an improved understanding of basic aerodynamic parameters such as diffusion factor, loading levels and incidence, when matching multistage compressor blade rows at design and at part-speed operation. Rotor loading levels and relative velocity ratio are correlated to the onset of compressor surge. NASA Stage 37 and the three-stage NASA 74-A axial compressors were analyzed and the results compared to test data. The code has been used to generate the performance map for the NASA 76-B three-stage axial compressor featuring variable geometry. The compressor stages were aerodynamically matched at off-design speeds by adjusting the variable inlet guide vane and variable stator geometry angles to control the rotor diffusion factor and incidence angles.

  8. Magnetic and axial-vector transitions of the baryon antidecuplet

    CERN Document Server

    Kim, H -Ch; Göke, K

    2007-01-01

    We report the recent results of the magnetic transitions and axial-vector transitions of the baryon antidecuplet within the framework of the chiral quark-soliton model. The dynamical model parameters are fixed by experimental data for the magnetic moments of the baryon octet, for the hyperon semileptonic decay constants, and for the singlet axial-vector constant. The transition magnetic moments $\\mu_{\\Lambda\\Sigma}$ and $\\mu_{N\\Delta}$ are well reproduced and other octet-decuplet and octet-antidecuplet transitions are predicted. In particular, the present calculation of $\\mu_{\\Sigma\\Sigma^*}$ is found to be below the upper bound $0.82\\mu_N$ that the SELEX collaboration measured very recently. The results explains consistently the recent findings of a new $N^*$ resonance from the GRAAL and Tohoku LNS group. We also obtain the transition axial-vector constants for the $\\Theta^+\\to KN$ from which the decay width of the $\\Theta^{+}$ pentaquark baryon is determined as a function of the pion-nucleon sigma term $\\Si...

  9. Bounding axial profile analysis for the topical report database

    International Nuclear Information System (INIS)

    Quantifying the open-quotes end effectsclose quotes reactivities of realistic end-of-cycle burnup distributions is important in performing criticality safety analyses for spent fuel shipping containers. Yankee Atomic Electric Company has compiled an axial burnup profile database (ABPD) for a large number of PWR fuel types. The profiles for fuel types with initially uniform axial loadings of U-235 and burnable poisons were collected from the ABPD to form the topical report database (TRD). Based on the TRD, a strategy was set up to find bounding profiles which conservatively estimate the maximum open-quotes end effectsclose quotes reactivities in different burnup ranges. A two-group, one-dimensional diffusion code, REALAX, was used to calculate the k-effectives and open-quotes end effectsclose quotes reactivities for each of the axially varying burnup distributions in the TRD. REALAX was also proven to have consistency with the well-known three-dimensional, multi-group diffusion code, DIF3D

  10. The new performance calculation method of fouled axial flow compressor.

    Science.gov (United States)

    Yang, Huadong; Xu, Hong

    2014-01-01

    Fouling is the most important performance degradation factor, so it is necessary to accurately predict the effect of fouling on engine performance. In the previous research, it is very difficult to accurately model the fouled axial flow compressor. This paper develops a new performance calculation method of fouled multistage axial flow compressor based on experiment result and operating data. For multistage compressor, the whole compressor is decomposed into two sections. The first section includes the first 50% stages which reflect the fouling level, and the second section includes the last 50% stages which are viewed as the clean stage because of less deposits. In this model, the performance of the first section is obtained by combining scaling law method and linear progression model with traditional stage stacking method; simultaneously ambient conditions and engine configurations are considered. On the other hand, the performance of the second section is calculated by averaged infinitesimal stage method which is based on Reynolds' law of similarity. Finally, the model is successfully applied to predict the 8-stage axial flow compressor and 16-stage LM2500-30 compressor. The change of thermodynamic parameters such as pressure ratio, efficiency with the operating time, and stage number is analyzed in detail. PMID:25197717

  11. Numerical Analysis of Erosion Caused by Biomimetic Axial Fan Blade

    Directory of Open Access Journals (Sweden)

    Jun-Qiu Zhang

    2013-01-01

    Full Text Available Damage caused by erosion has been reported in several industries for a wide range of situations. In the present work, a new method is presented to improve the erosion resistance of machine components by biomimetic method. A numerical investigation of solid particle erosion in the standard and biomimetic configuration blade of axial fan is presented. The analysis consists in the application of the discrete phase model, for modeling the solid particles flow, and the Eulerian conservation equations to the continuous phase. The numerical study employs computational fluid dynamics (CFD software, based on a finite volume method. User-defined function was used to define wear equation. Gas/solid flow axial fan was simulated to calculate the erosion rate of the particles on the fan blades and comparatively analyzed the erosive wear of the smooth surface, the groove-shaped, and convex hull-shaped biomimetic surface axial flow fan blade. The results show that the groove-shaped biomimetic blade antierosion ability is better than that of the other two fan blades. Thoroughly analyze of antierosion mechanism of the biomimetic blade from many factors including the flow velocity contours and flow path lines, impact velocity, impact angle, particle trajectories, and the number of collisions.

  12. Axial Non-linear Dynamic Soil-Pile Interaction - Keynote

    Directory of Open Access Journals (Sweden)

    Holeyman A.

    2014-01-01

    Full Text Available This keynote lecture describes recent analytical and numerical advances in the modeling of the axial nonlinear dynamic interaction between a single pile and its embedding soil. On one hand, analytical solutions are developed for assessing the nonlinear axial dynamic response of the shaft of a pile subjected to dynamic loads, and in particular to vibratory loads. Radial inhomogeneity arising from shear modulus degradation is evaluated over a range of parameters and compared with those obtained by other authors and by a numerical radial discrete model simulating the pile and soil movements from integration of the laws of motion. New approximate non linear solutions for axial pile shaft behaviour developed from general elastodynamic equations are presented and compared to existing linear solutions. The soil non linear behaviour and its ability to dissipate mechanical energy upon cyclic loading are shown to have a significant influence on the mechanical impedance provided by the surrounding soil against pile shaft movement. The limitations of over-simplified modelling of pile response are highlighted.

  13. Can the nucleon axial charge be O(Nc^0)?

    CERN Document Server

    Kojo, Toru

    2012-01-01

    The nucleon self-energy and its relation to the nucleon axial charge gA are discussed at large Nc. The energy is compared for the hedgehog, conventional, and recently proposed dichotomous nucleon wavefunctions which give different values for gA. We consider their energies at both perturbative and non-perturbative levels. In perturbative estimates, we take into account the pion exchanges among quarks up to the third orders of axial charge vertices, including the many-body forces such as the Wess-Zumino terms. It turns out that the perturbative pion exchanges among valence quarks give the same leading Nc contributions for three wavefunctions, while their mass differences are O(Lamba_qcd). The signs of splittings flip for different orders of the axial charge vertices, so it is hard to conclude which one is the most energetically favored. For non-perturbative estimates involving the modification of quark bases, we use the chiral quark soliton model as an illustration. With the hedgehog quark wavefunctions with gA...

  14. A mini axial and a permanent maglev radial heart pump.

    Science.gov (United States)

    Qian, Kun-Xi; Ru, Wei-Min; Wang, Hao; Jing, Teng

    2007-01-01

    The implantability and durability have been for decades the focus of artificial heart R&D. A mini axial and a maglev radial pump have been developed to meet with such requirements.The mini axial pump weighing 27g (incl.5g rotor) has an outer diameter of 21mm and a length of 10mm in its largest point, but can produce a maximal blood flow of 6l/min with 50mmHg pressure increase. Therefore, it is suitable for the patients of 40-60kg body weight. For other patients of 60-80kg or 80-100kg body weight, the mini axial pumps of 23mm and 25mm outer diameter had been developed before, these devices were acknowledged to be the world smallest LVADs by Guinness World Record Center in 2004.The permanent maglev radial pump weighing 150g is a shaft-less centrifugal pump with permanent magnetic bearings developed by the author. It needs no second coil for suspension of the rotor except the motor coil, different from all other maglev pumps developed in USA, Japan, European, etc. Thus no detecting and controlling systems as well as no additional power supply for maglev are necessary. The pump can produce a blood flow up to as large as 10l/min against 100mmHg pressure.An implantable and durable blood pump will be a viable alternative to natural donor heart for transplantation. PMID:19662120

  15. The New Performance Calculation Method of Fouled Axial Flow Compressor

    Directory of Open Access Journals (Sweden)

    Huadong Yang

    2014-01-01

    Full Text Available Fouling is the most important performance degradation factor, so it is necessary to accurately predict the effect of fouling on engine performance. In the previous research, it is very difficult to accurately model the fouled axial flow compressor. This paper develops a new performance calculation method of fouled multistage axial flow compressor based on experiment result and operating data. For multistage compressor, the whole compressor is decomposed into two sections. The first section includes the first 50% stages which reflect the fouling level, and the second section includes the last 50% stages which are viewed as the clean stage because of less deposits. In this model, the performance of the first section is obtained by combining scaling law method and linear progression model with traditional stage stacking method; simultaneously ambient conditions and engine configurations are considered. On the other hand, the performance of the second section is calculated by averaged infinitesimal stage method which is based on Reynolds’ law of similarity. Finally, the model is successfully applied to predict the 8-stage axial flow compressor and 16-stage LM2500-30 compressor. The change of thermodynamic parameters such as pressure ratio, efficiency with the operating time, and stage number is analyzed in detail.

  16. HTS axial flux induction motor with analytic and FEA modeling

    International Nuclear Information System (INIS)

    Highlights: •A high temperature superconductor axial flux induction motor and a novel maglev scheme are presented. •Analytic method and finite element method have been adopted to model the motor and to calculate the force. •Magnetic field distribution in HTS coil is calculated by analytic method. •An effective method to improve the critical current of HTS coil is presented. •AC losses of HTS coils in the HTS axial flux induction motor are estimated and tested. -- Abstract: This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested

  17. Are we ready for positron emission tomography/computed tomography-based target volume definition in lymphoma radiation therapy?

    Science.gov (United States)

    Yeoh, Kheng-Wei; Mikhaeel, N George

    2013-01-01

    Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) has become indispensable for the clinical management of lymphomas. With consistent evidence that it is more accurate than anatomic imaging in the staging and response assessment of many lymphoma subtypes, its utility continues to increase. There have therefore been efforts to incorporate PET/CT data into radiation therapy decision making and in the planning process. Further, there have also been studies investigating target volume definition for radiation therapy using PET/CT data. This article will critically review the literature and ongoing studies on the above topics, examining the value and methods of adding PET/CT data to the radiation therapy treatment algorithm. We will also discuss the various challenges and the areas where more evidence is required.

  18. Experimental studies of axial magnetic fields generated in ultrashort-pulse laser-plasma interaction

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The quasistatic axial magnetic fields in plasmas produced by ultrashort laser pulses were measured by measuring the Faraday rotation angle of the backscattered emission. The spatial distribution of the axial magnetic field was obtained with a peak value as high as 170 Tesla. Theory suggests that the axial magnetic field is generated by dynamo effect in laser-plasma interaction.

  19. Double-Difference Adjoint Tomography

    Science.gov (United States)

    Yuan, Yanhua O.; Simons, Frederik J.; Tromp, Jeroen

    2016-04-01

    We introduce a double-difference method for the inversion of seismic wavespeed structure by adjoint tomography. Differences between seismic observations and model-based predictions at individual stations may arise from factors other than structural heterogeneity, such as errors in the assumed source-time function, inaccurate timings, and systematic uncertainties. To alleviate the corresponding nonuniqueness in the inverse problem, we construct differential measurements between stations, thereby largely canceling out the source signature and systematic errors. We minimize the discrepancy between observations and simulations in terms of differential measurements made on station pairs. We show how to implement the double-difference concept in adjoint tomography, both theoretically and in practice. We compare the sensitivities of absolute and differential measurements. The former provide absolute information on structure along the ray paths between stations and sources, whereas the latter explain relative (and thus higher-resolution) structural variations in areas close to the stations. Whereas in conventional tomography, a measurement made on a single earthquake-station pair provides very limited structural information, in double-difference tomography, one earthquake can actually resolve significant details of the structure. The double-difference methodology can be incorporated into the usual adjoint tomography workflow by simply pairing up all conventional measurements; the computational cost of the necessary adjoint simulations is largely unaffected. Rather than adding to the computational burden, the inversion of double-difference measurements merely modifies the construction of the adjoint sources for data assimilation.

  20. Anterior Segment Tomography with the Cirrus Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Eduardo B. Rodrigues

    2012-01-01

    Full Text Available Optical coherence tomography (OCT is an optical acquisition method to examine biological tissues. In recent years, OCT has become an important imaging technology used in diagnosing and following macular pathologies. Further development enabled application of optical coherence tomography in evaluation of the integrity of the nerve fiber layer, optic nerve cupping, anterior chamber angle, or corneal topography. In this manuscript we overview the use of OCT in the clinical practice to enable corneal, iris, ciliary body, and angle evaluation and diagnostics.

  1. Estimation of Chromatographic Columns Performances using Computer Tomography and CFD Simulations

    DEFF Research Database (Denmark)

    Schmidt, Irma; Lottes, Florian; Minceva, Mirjana;

    2011-01-01

    The flow inside a chromatographic column depends decisively on the packed bed inside. Non‐destructive X‐ray computed tomography (CT) was applied as a novel measurement technique to visualize the distribution of velocity and axial dispersion coefficients in preparative scale columns. The results...... show, that spherical particles seem to be more efficient than irregular ones in terms of HETP, which has to be partly a result of the more homogeneous flow profile they induce. The prediction of column performance in dependence of the structure of the packed bed was simulated by CFD (Computational...

  2. Nanometer resolution optical coherence tomography using broad bandwidth XUV and soft x-ray radiation

    OpenAIRE

    Silvio Fuchs; Christian Rödel; Alexander Blinne; Ulf Zastrau; Martin Wünsche; Vinzenz Hilbert; Leif Glaser; Jens Viefhaus; Eugene Frumker; Paul Corkum; Eckhart Förster; Paulus, Gerhard G.

    2016-01-01

    Optical coherence tomography (OCT) is a non-invasive technique for cross-sectional imaging. It is particularly advantageous for applications where conventional microscopy is not able to image deeper layers of samples in a reasonable time, e.g. in fast moving, deeper lying structures. However, at infrared and optical wavelengths, which are commonly used, the axial resolution of OCT is limited to about 1 μm, even if the bandwidth of the light covers a wide spectral range. Here, we present extre...

  3. Contribution to regularizing iterative method development for attenuation correction in gamma emission tomography

    International Nuclear Information System (INIS)

    This study is concerned with the transverse axial gamma emission tomography. The problem of self-attenuation of radiations in biologic tissues is raised. The regularizing iterative method is developed, as a reconstruction method of 3 dimensional images. The different steps from acquisition to results, necessary to its application, are described. Organigrams relative to each step are explained. Comparison notion between two reconstruction methods is introduced. Some methods used for the comparison or to bring about the characteristics of a reconstruction technique are defined. The studies realized to test the regularizing iterative method are presented and results are analyzed

  4. Interpretation of computed tomography imaging of the eye and orbit. A systematic approach

    Directory of Open Access Journals (Sweden)

    Naik Milind

    2002-01-01

    Full Text Available Computed tomography (CT has revolutionised the diagnosis and management of ocular and orbital diseases. The use of thin sections with multiplanar scanning (axial, coronal and sagittal planes and the possibility of three-dimensional reconstruction permits thorough evaluation. To make the most of this technique, users must familiarize themselves with the pertinent CT principles and terminology. The diagnostic yield is optimal when the ophthalmologist and radiologist collaborate in the radiodiagnostic workup. In this article we describe a systematic approach to the interpretation of ocular and orbital CT scans.

  5. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  6. Peri-implant biomechanical responses to standard, short-wide, and mini implants supporting single crowns under axial and off-axial loading (an in vitro study).

    Science.gov (United States)

    Kheiralla, Lamia Sayed; Younis, Jihan Farouk

    2014-02-01

    This study compared the biomechanical responses of 3 single crowns supported by 3 different implants under axial and off-axial loading. A standard implant (3.75 mm diameter, 13 mm length), a mini implant (3 mm diameter, 13 mm length), and a short-wide implant (5.7 mm diameter, 8 mm length) were embedded in epoxy resin by the aid of a surveyor to ensure their parallelism. Each implant supported a full metal crown made of Ni-Cr alloy with standardized dimensions. Strain gauges and finite element analysis (FEA) were used to measure the strain induced under axial and off-axial functional loads of 300 N. Results showed that mini implants recorded the highest microstrains, under both axial and off-axial loading. All implants showed a considerable increase in strain values under off-axial loading. Standard and short-wide implants proved to be preferable in supporting crowns, as the standard implant showed the lowest strains under axial and off-axial loading using FEA simulation, while the short-wide implant showed the lowest strains under nonaxial loading using strain gauge analysis.

  7. X-ray computed-tomography imaging of gas migration in water-saturated sediments: From capillary invasion to conduit opening

    Science.gov (United States)

    Choi, Jeong-Hoon; Seol, Yongkoo; Boswell, Ray; Juanes, Ruben

    2011-09-01

    The strong coupling between multiphase flow and sediment mechanics determines the spatial distribution and migration dynamics of gas percolating through liquid-filled soft granular media. Here, we investigate, by means of controlled experiments and computed tomography (CT) imaging, the preferential mode of gas migration in three-dimensional samples of water-saturated silica-sand and silica-silt sediments. Our experimental system allowed us to independently control radial and axial confining stresses and pore pressure while performing continuous x-ray CT scanning. The CT image analysis of the three-dimensional gas migration provides the first experimental confirmation that capillary invasion preferentially occurs in coarse-grained sediments whereas grain displacement and conduit openings are dominant in fine-grained sediments. Our findings allow us to rationalize prior field observations and pore-scale modeling results, and provide critical experimental evidence to explain the means by which conduits for the transit of methane gas may be established through the gas hydrate stability zone in oceanic sediments, and cause large episodic releases of carbon into the deep ocean.

  8. Assessment of Safety and Interference Issues of Radio Frequency Identification Devices in 0.3 Tesla Magnetic Resonance Imaging and Computed Tomography

    Directory of Open Access Journals (Sweden)

    M. Periyasamy

    2014-01-01

    Full Text Available The objective of this study was to evaluate two issues regarding magnetic resonance imaging (MRI including device functionality and image artifacts for the presence of radio frequency identification devices (RFID in association with 0.3 Tesla at 12.7 MHz MRI and computed tomography (CT scanning. Fifteen samples of RFID tags with two different sizes (wristband and ID card types were tested. The tags were exposed to several MR-imaging conditions during MRI examination and X-rays of CT scan. Throughout the test, the tags were oriented in three different directions (axial, coronal, and sagittal relative to MRI system in order to cover all possible situations with respect to the patient undergoing MRI and CT scanning, wearing a RFID tag on wrist. We observed that the tags did not sustain physical damage with their functionality remaining unaffected even after MRI and CT scanning, and there was no alternation in previously stored data as well. In addition, no evidence of either signal loss or artifact was seen in the acquired MR and CT images. Therefore, we can conclude that the use of this passive RFID tag is safe for a patient undergoing MRI at 0.3 T/12.7 MHz and CT Scanning.

  9. Intraperitoneal tuberculous abscess: computed tomography features

    Institute of Scientific and Technical Information of China (English)

    Peng; Dong; Jing-Jing; Chen; Xi-Zhen; Wang; Ya-Qin; Wang

    2015-01-01

    AIM: To evaluate the computed tomography(CT) features of intraperitoneal tuberculous abscess(IPTA). METHODS: Eight patients with IPTA confirmed by pathology were analyzed retrospectively. The clinical symptoms, medical images, and surgical findings were evaluated. Involvement of the intestine, peritoneum, viscera, and lymph nodes was also assessed. RESULTS: All 8 patients had a history of abdominal discomfort for 1 to 6 mo. Physical examination revealed a palpable abdominal mass in 6 patients. Three patients had no evidence of pulmonary tuberculosis(TB). All IPTAs(11 abscesses) were seen as a multiseptated, peripherally enhanced, hypodense mass with enlarged, rim-enhanced lymph nodes. The largest abscess diameter ranged from 4.5 cm to 12.2 cm. CT showed 2 types of IPTA: Lymph node fusion and encapsulation. Of the 8 patients, one had liver tuberculosis and one had splenic and ovarian tuberculosis. Two cases showed involvement of the terminal ileum and ileocecal junction. Ascites were found in 4 cases. Three patients had peritonitis and mesenteritis. Three patients showed involvement of the omentum. Three patients had histological evidence of caseating granuloma, and 5 had histological evidence of acid-fast bacilli. CONCLUSION: CT is crucial in the detection and characterization of IPTA. Certain CT findings are necessary for correct diagnosis.

  10. Noncontact photoacoustic tomography imaging using a low-coherence interferometer with rapid detection of phase modulation

    Science.gov (United States)

    Liu, Jun; Tang, Zhilie; Tang, Hongchun; Wu, Yongbo; Wang, Yi

    2014-09-01

    A photoacoustic tomography imaging system using a low-coherence interferometer with rapid detection of phase modulation was designed, fabricated, and tested for biologic imaging. A noncontact probing technique was applied to improve the practicability of the system. The technique is experimentally verified by the image of a simulated tissue sample and the blood vessels within a mouse ear flap (pinna) in vivo. The system's axial and lateral resolutions are evaluated at 45 and ~15 μm, respectively. The system's imaging depth is 1mm in a special phantom. The results show that the system has the feasibility to be used as a photoacoustic tomography imaging method, and it may provide a kind of possibility of noncontact real-time PAT.

  11. In vitro birefringence imaging with spectral domain polarization-sensitive optical coherence tomography

    Institute of Scientific and Technical Information of China (English)

    Qiang Gong; Chuanmao Fan; Fan Zhang; Jianquan Yao

    2008-01-01

    Spectral domain polarization-sensitive optical coherence tomography (SDPS-OCT) is a depth-resolved polarization-sensitive interferometry which integrates polarization optics into spectral domain optical co-herence tomography (SD-OCT). This configuration can obtain birefringence information of samples and improve the imaging speed. In this paper, horizontally polarized light is used to replace natural light of the source. Then, right-rotated circularly polarized light is the incident sample light. To obtain two orthogonal components of the polarized interferogram, the reflected light of the reference arm is set to be 45° linearly polarized light. These two components are acquired by two spectrometers synchronously. The system was employed to achieve 12.8-#m axial resolution and 4.36-#m transverse resolution. We have imaged in vitro chicken tendon and muscle tissues with these system.

  12. Recent advances in neutron tomography

    International Nuclear Information System (INIS)

    Neutron imaging has been shown to be an excellent imaging tool for many nondestructive evaluation applications. Significantly improved contrast over X-ray images is possible for materials commonly found in engineering assemblies. The major limitations have been the neutron source and detection. A low cost, position sensitive neutron tomography detector system has been designed and built based on an electro-optical detector system using a LiF-ZnS scintillator screen and a cooled charge coupled device. This detector system can be used for neutron radiography as well as two and three-dimensional neutron tomography. Calculated performance of the system predicted near-quantum efficiency for position sensitive neutron detection. Experimental data was recently taken using this system at McClellan Air Force Base, Air Logistics Center, Sacramento, CA. With increased availability of low cost neutron sources and advanced image processing, neutron tomography will become an increasingly important nondestructive imaging method

  13. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus;

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  14. Computer tomography in acute pyelonephritis

    Energy Technology Data Exchange (ETDEWEB)

    Triller, J.; Scheidegger, J.; Terrier, F.

    1983-07-01

    Computer tomography of the kidneys was performed on 30 patients with acute renal infections (acute suppurative pyelonephritis, acute renal abscess, infected cyst, pyelonephrosis, calculus perforation, retroperitoneal abscess). Computer tomography provided more accurate information concerning the extent of the renal and extra-renal inflammatory process than did the urogram or sonogram. This may significantly affect the choice of treatment, particularly concerning the use of drugs or of surgery. Angiography and retrograde pyelography may be used in selected cases, especially where there is a suspicion of acute bacterial nephritis, renal vein thrombosis or ureteric obstruction.

  15. Full tomography from compatible measurements

    CERN Document Server

    Rehacek, J; Bouchal, Z; Celechovsky, R; Rigas, I; Sanchez-Soto, L L

    2009-01-01

    We put forward a reconstruction scheme prompted by the relation between a von Neumann measurement and the corresponding informationally complete measurement induced in a relevant reconstruction subspace. This method is specially suited for the full tomography of complex quantum systems, where the intricacies of the detection part of the experiment can be greatly reduced provided some prior information is available. In broader terms this shows the importance of \\sugg{this often-disregarded} prior information in quantum theory. The proposed technique is illustrated with an experimental tomography of photonic vortices of moderate dimension.

  16. Second harmonic optical coherence tomography

    CERN Document Server

    Jiang, Y; Wang, Y; Chen, Z; Jiang, Yi; Tomov, Ivan; Wang, Yimin; Chen, Zhongping

    2004-01-01

    Second harmonic optical coherence tomography, which uses coherence gating of second-order nonlinear optical response of biological tissues for imaging, is described and demonstrated. Femtosecond laser pulses were used to excite second harmonic waves from collagen harvested from rat tail tendon and a reference nonlinear crystal. Second harmonic interference fringe signals were detected and used for image construction. Because of the strong dependence of second harmonic generation on molecular and tissue structures, this technique offers contrast and resolution enhancement to conventional optical coherence tomography.

  17. Application of the wavelet transforms on axial strain calculation in ultrasound elastography

    Institute of Scientific and Technical Information of China (English)

    LUO Jianwen; BAI Jing; SHAO Jinhua

    2006-01-01

    In ultrasound elastography, the axial strain distribution within biological tissues is calculated as the numerical derivative (differentiation) of the estimated axial displacement field. Unfortunately, the numerical derivative is unstable because it can greatly amplify the noises, especially at high frequencies. This work focuses on the axial strain calculation from the estimated axial displacements using wavelet transforms (WTs), including continuous wavelet transforms (CWTs) and discrete wavelet transforms (DWTs). The feasibility of the WT-based method using the quadratic spline function is verified by computer simulations and some phantom data. Results indicate that the WT-based method can effectively reduce the noise amplification in axial strain calculation.

  18. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... Tools & Resources Stroke More Single Photon Emission Computed Tomography (SPECT) Updated:Sep 11,2015 What is a ... Heart Attack Myocardial Perfusion Imaging (MPI) Positron Emission Tomography (PET) Radionuclide Ventriculography, Radionuclide Angiography, MUGA Scan Heart ...

  19. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Blood Pressure Tools & Resources Stroke More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 3,2015 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  20. Positron emission tomography/computerized tomography in lung cancer

    OpenAIRE

    Sahiner, Ilgin; Vural, Gulin Ucmak

    2014-01-01

    Positron emission tomography (PET) using 2-(18F)-flouro-2-deoxy-D-glucose (FDG) has emerged as a useful tool in the clinical work-up of lung cancer. This review article provides an overview of applications of PET in diagnosis, staging, treatment response evaluation, radiotherapy planning, recurrence assessment and prognostication of lung cancer.